Everbilt SCN250-LQ Guía del usuario

Categoría
Pistolas de calor de potencia
Tipo
Guía del usuario
210*55mm
• Connect the pump DIRECTLY to a properly grounded, 115V GFCI outlet and
never use an extension cord to power this pump
• Pull plug before servicing this pump
• This pump has not been tested or approved for use in swimming pools or in
salt-water marine areas
• Do not pump flammable or explosive liquids, pump water only with this pump
• To reduce risk of electrical shock, fully read, follow and save the operating and
installation instructions before attempting to install or operate this pump
• Do not run this pump dry
NOTICE: Do not handle pump with wet hands or when standing on a wet surface,
or in water
• Conecte la bomba DIRECTAMENTE a una toma de tierra, nunca utilice un cable de
extensión para proporcionar alimentación a la bomba
• Desconecte la bomba antes de cualquier clase de mantenimiento
• Esta bomba no se ha puesto a prueba y no ha sido aprobada para uso en piscinas
o en áreas de agua salada
• No bombee líquidos inflamables o explosivos, bombee solamente agua con esta
bomba
• Para reducir el riesgo de descarga eléctrica, lea totalmente, siga y guarde las
instrucciones de uso e instalación antes de intentar instalar o utilizar la bomba
• No haga funcionar esta bomba en seco
AVISO: No maneje la bomba con las manos mojadas o estando en agua o en la
superficie mojada
MADE IN CHINA HECHO EN CHINA
ADVERTENCIA
WARNING
cord tag
70*17mm
logo
name plate
60*35mm
Serial No./Serial No.: 000000
Date Code/Código de Fecha: 1439
Pedestal Sump Pump
Bomba De Sumidero De Pedestal
115V 60Hz 1/3HP 4.0Amps
THERMALLY PROTECTED
PROTECCIÓN TÉRMICA
SKU 1001 093 963
Model SCN250-LQ
Pit debe estar cubierto. Por lo general es de 12'' de
diámetro y 18'pies de profundidad. Consulte el manual
del propietario de la bomba para el pozo de tamaño
necesario. Instalar en una superficie dura: ladrillo,
cemento o bloques de concreto; hay arena, arcilla o
grava.
Inserte el extremo plano de la varilla del flotador (1) a través
del ojo de la guía de la varilla.
Deslice un tope de la varilla (2) en la varilla del flotador (1) antes de
pasar la varilla a través del ojo del interruptor de la bomba (3).
Deslizar el segundo tope de la varilla (4) sobre la varilla
(1) después de pasar a través del ojo del interruptor (3).
Coloque las dos paradas de la barra:
A. Posición del segundo tope de la varilla (4) a ras con la
parte superior de la varilla (1).
B. Colocar la varilla de tope inferior (2) dentro de 7 pulg.
(17,8 cm) de brazo de palanca del interruptor (3).
Guía de Referencia Rápida
SE NECESITARÁ
1. Requisitos Sump
ADVERTENCIA:
Herramientas:
Materiales
PVC
12’’ diameter
18’’depth
Sump Pit
3’’(76)10’’(254)SNC250
Instale la tubería de descarga y la válvula de la bomba:
A. Use cinta de teflón-NO pasta de juntas.
B. Apriete el tubo en la bomba.
C. Instale la válvula de retención como cerca de la bomba
como posible.
D. perforar un agujero de 1/8" anti-esclusa de aire como se
muestra. El agujero debe estar en el sumidero.
5. Inserción La Bomba4. Instalación de la tubería de descarga
Coloque la bomba en el sumidero; asegurarse de que
nada interfiere con la operación del interruptor.
Compruebe el funcionamiento de la bomba, llenando el
sumidero con agua hasta que la bomba arranque. Deje
que se ejecute hasta que haya bombeado por el
sumidero y se detuvo.
Conecte la bomba a un circuito de 15 amperios.
El circuito debe estar protegido GFCI y dedicada a la
bomba de sumidero.
2. Inserción La Varilla Del Flotador
7 in.
2
1
4
3
3. Deslizamiento De La Parada
Segunda Varilla A La Varilla
1
2
3
A menos que se haya indicado lo contrario, los modelos
con un interruptor de flotador anclado requieren un pozo
de recogida con un diàmetro mínimo de 14”.
Los Modelos con un interruptor de flotador vertical
requieren un foso de recogida de por lo menos 10” de
diàmetro.
Bomba de sumidero (La bomba que se ilustra es típica)
Es importante leer el manual para obtener información sobre la instalación, la operación
y la seguridad.Esta guía no complementa ni reemplaza al Manual del Propietario.
Válvula de retención
Adaptador roscado PVC
Tubería de descarga de
1-1/4” ó de 1-1/2”
Bridas
Destornillador
Sierra de acro
Llave para tubos
Pinzas ajustables a
cremallera
Cinta métrica
Tubo de ABS o de PVC
de 1-1/4” ó de 1-1/2”
Cemento ABS o PVC
(según el tubo)
Adaptador fileteado
(Tubo a Bomaba)
1-1/4'' o 1-1/2''
Válvula de Retención
ADVERTENCIA: EI pegamento para tuberías de plástic
es extremadanente inflammable. Siga las instrucciones
del fabricante del pegamento con atención si La
instalación se debe realizer conforme a todas las
leyes,los códigos y las normas correspondientes. Si se
hace caso omiso a estas disposiciones,existe el peligor
de que el product falle, y ocurran danos materiales y/o
lesions personales.
No use un cordón de alargue con una bomba de
sumidero.
Inspeccione la admisión de la bomba con regularidad y
limpie la suciedad que se haya acumulado.
La bomba se debe encender y apagar a los niveles de
agua que aparecen a continuación, Consulte su manual
de propietario de la bomba para determinar la gama de
bombeo para su boma.
Ajuste del interruptor en pulgadas(mm)
No
If you have questions regarding your product or require
warranty assistance, please call our customer service
toll-free helpline
Do not return your product to the store.
Call us rst!
Contact us for assistance, we're here to help.
En contacto con nosotros para obtener ayuda, estamos aquí para ayudar.
No devuelva su proudct a la tienda.
Llámenos primero!
Si tiene alguna pregunta con respecto a su producto o
si necesita asistencia con la garantía, por favor llame
a nuestra línea de ayuda de servicio al cliente de gratis
1-844-241-5521
Let Us Help You !
Permítanos Help !

Transcripción de documentos

70*17mm logo 60*35mm SKU 1001 093 963 Model SCN250-LQ Pedestal Sump Pump Bomba De Sumidero De Pedestal 115V 60Hz 1/3HP 4.0Amps THERMALLY PROTECTED PROTECCIÓN TÉRMICA Serial No./Serial No.: 000000 Date Code/Código de Fecha: 1439 name plate 210*55mm WARNING ADVERTENCIA • Connect the pump DIRECTLY to a properly grounded, 115V GFCI outlet and never use an extension cord to power this pump • Pull plug before servicing this pump • This pump has not been tested or approved for use in swimming pools or in salt-water marine areas • Do not pump flammable or explosive liquids, pump water only with this pump • To reduce risk of electrical shock, fully read, follow and save the operating and installation instructions before attempting to install or operate this pump • Do not run this pump dry • NOTICE: Do not handle pump with wet hands or when standing on a wet surface, or in water MADE IN CHINA cord tag • Conecte la bomba DIRECTAMENTE a una toma de tierra, nunca utilice un cable de extensión para proporcionar alimentación a la bomba • Desconecte la bomba antes de cualquier clase de mantenimiento • Esta bomba no se ha puesto a prueba y no ha sido aprobada para uso en piscinas o en áreas de agua salada • No bombee líquidos inflamables o explosivos, bombee solamente agua con esta bomba • Para reducir el riesgo de descarga eléctrica, lea totalmente, siga y guarde las instrucciones de uso e instalación antes de intentar instalar o utilizar la bomba • No haga funcionar esta bomba en seco • AVISO: No maneje la bomba con las manos mojadas o estando en agua o en la superficie mojada HECHO EN CHINA Guía de Referencia Rápida Bomba de sumidero (La bomba que se ilustra es típica) Materiales: SE NECESITARÁ: Herramientas: Adaptador fileteado (Tubo a Bomaba) Destornillador Sierra de acro Tubo de ABS o de PVC de 1-1/4” ó de 1-1/2” Es importante leer el manual para obtener información sobre la instalación, la operación y la seguridad.Esta guía no complementa ni reemplaza al Manual del Propietario. 1. Requisitos Sump 2. Inserción La Varilla Del Flotador Pit debe estar cubierto. Por lo general es de 12'' de diámetro y 18'pies de profundidad. Consulte el manual del propietario de la bomba para el pozo de tamaño necesario. Instalar en una superficie dura: ladrillo, cemento o bloques de concreto; hay arena, arcilla o grava. Inserte el extremo plano de la varilla del flotador (1) a través del ojo de la guía de la varilla. Deslice un tope de la varilla (2) en la varilla del flotador (1) antes de pasar la varilla a través del ojo del interruptor de la bomba (3). Pinzas ajustables a cremallera PVC 1-1/4'' o 1-1/2'' Válvula de Retención Llave para tubos Cinta métrica Bridas 3. Deslizamiento De La Parada Segunda Varilla A La Varilla Deslizar el segundo tope de la varilla (4) sobre la varilla (1) después de pasar a través del ojo del interruptor (3). Coloque las dos paradas de la barra: A. Posición del segundo tope de la varilla (4) a ras con la parte superior de la varilla (1). B. Colocar la varilla de tope inferior (2) dentro de 7 pulg. (17,8 cm) de brazo de palanca del interruptor (3). 7 in. 4 3 3 Cemento ABS o PVC (según el tubo) A menos que se haya indicado lo contrario, los modelos con un interruptor de flotador anclado requieren un pozo de recogida con un diàmetro mínimo de 14”. Los Modelos con un interruptor de flotador vertical requieren un foso de recogida de por lo menos 10” de diàmetro. 1 18’’depth Sump Pit 4. Instalación de la tubería de descarga 5. Inserción La Bomba Instale la tubería de descarga y la válvula de la bomba: A. Use cinta de teflón-NO pasta de juntas. B. Apriete el tubo en la bomba. C. Instale la válvula de retención como cerca de la bomba como posible. D. perforar un agujero de 1/8" anti-esclusa de aire como se muestra. El agujero debe estar en el sumidero. Coloque la bomba en el sumidero; asegurarse de que nada interfiere con la operación del interruptor. Compruebe el funcionamiento de la bomba, llenando el sumidero con agua hasta que la bomba arranque. Deje que se ejecute hasta que haya bombeado por el sumidero y se detuvo. Conecte la bomba a un circuito de 15 amperios. El circuito debe estar protegido GFCI y dedicada a la bomba de sumidero. Válvula de retención Tubería de descarga de 1-1/4” ó de 1-1/2” 2 12’’ diameter ADVERTENCIA: ADVERTENCIA: EI pegamento para tuberías de plástic es extremadanente inflammable. Siga las instrucciones del fabricante del pegamento con atención si La instalación se debe realizer conforme a todas las leyes,los códigos y las normas correspondientes. Si se hace caso omiso a estas disposiciones,existe el peligor de que el product falle, y ocurran danos materiales y/o lesions personales. No use un cordón de alargue con una bomba de sumidero. Inspeccione la admisión de la bomba con regularidad y limpie la suciedad que se haya acumulado. La bomba se debe encender y apagar a los niveles de agua que aparecen a continuación, Consulte su manual de propietario de la bomba para determinar la gama de bombeo para su boma. Ajuste del interruptor en pulgadas(mm) 2 1 SNC250 Adaptador roscado PVC Sí No 10’’(254) 3’’(76) Let Us Help You ! Permítanos Help ! Do not return your product to the store. Call us first! If you have questions regarding your product or require warranty assistance, please call our customer service toll-free helpline No devuelva su proudct a la tienda. Llámenos primero! Si tiene alguna pregunta con respecto a su producto o si necesita asistencia con la garantía, por favor llame a nuestra línea de ayuda de servicio al cliente de gratis 1-844-241-5521 Contact us for assistance, we're here to help. En contacto con nosotros para obtener ayuda, estamos aquí para ayudar.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Everbilt SCN250-LQ Guía del usuario

Categoría
Pistolas de calor de potencia
Tipo
Guía del usuario

en otros idiomas