1 INFORMAÇÕES DE SEGURANÇA
1.1 AVISOS DE SEGURANÇA
NOTA!
Somente utilizar o módulo de expansão de I/O (CFW300-IODRB)
nos inversores WEG série CFW300-2.
Recomenda-se a leitura do manual do usuário do CFW300-2 antes
de instalar ou operar esse acesrio.
O conteúdo deste guia fornece informações importantes para
o correto entendimento e bom funcionamento deste módulo.
1.2 RECOMENDAÇÕES PRELIMINARES
ATENÇÃO!
Sempre desconecte a alimentação geral antes de conectar ou
desconectar os acessórios do inversor de frequência fitness
drive CFW300-2.
Aguarde pelo menos 10 minutos para garantir a desenergização
completa do inversor.
2 INFORMAÇÕES GERAIS
Este guia orienta na instalação, configurão e operão do módulo de
expansão de I/O (CFW300-IODRB).
3 CONTEÚDO DA EMBALAGEM
Ao receber o produto, verificar se a embalagem contém:
Acessório em embalagem anti-estática.
Guia de instalação, configuração e operação.
4 INSTALAÇÃO DO ACESSÓRIO
O CFW300-IODRB é facilmente conectado ao inversor de frequência
fitness drive CFW300-2 utilizando o conceito "plug-and-play". Os
procedimentos abaixo devem ser seguidos para a correta instalação e
colocação em funcionamento:
1. Com o inversor desenergizado, retire a tampa de acessórios de
expansão de IO’s e a tampa de proteção da conexão dos acessórios
de expansão de IO’s (XC4) do inversor (Figura A1).
2. Encaixe o acesrio a ser instalado conforme indicado na Figura A1.
3. Energize o inversor.
5 CONFIGURAÇÕES
As conexões do acessório CFW300-IODRB devem ser feitas no conector
de expansão de I/O conforme Tabela 1. Os pinos do conector do acessório
o apresentados na Figura A2. A Figura A3 apresenta exemplos de
ligação.
Tabela 1: Sinais do conector de expansão I/O
Conector Descrição
13 Tx Transmissão da comunicação serial RS232
14 Rx Recepção da comunicação serial RS232
15 GND Referência (0 V) para Sensor Hall (fio branco)
16 HALL Sinal do Sensor Hall (fio vermelho)
17 +5 V +5 Vcc do Sensor Hall (fio preto)
18 C Comum das saídas a relé
19 DO2 Saída a relé (Liga/Desliga)
(*)
Tensão máxima: 250 Vca
Corrente máxima: 5 A
20 DO3 Saída a relé (Horário/Anti-horário)
(*)
Tensão máxima: 250 Vca
Corrente máxima: 5 A
(*) As saídas a relé disponíveis são do tipo NA.
(**) Disjuntor a ser definido.
NOTA!
A versão de software do acessório CFW300-IODRB pode ser
visualizada no parâmetro P024 do inversor CFW300-2.
Português
APPENDIX A - FIGURES
ANEXO A - FIGURAS
(a) Removal of the accessory and connection protection covers (XC4) from the IO expansion
(a) Remoción de las tapas de accesorios y de protección de la conexión (XC4) de la
expansión de IO´s
(a) Remoção das tampas de acessórios e de proteção da conexão (XC4) da expansão de IO's
(b) Accessory connection
(b) Conexión del accesorio
(b) Conexão do acessório
Figure A1: (a) and (b): Installation of accessory
Figura A1: (a) y (b): Instalación de accesorio
Figura A1: (a) e (b): Instalação de acessório
20.6 [0.81]
64 [2.52]
46.8 [1.84]
I/O expansion connector
Conector de expansión de I/O
Conector de expansão de I/O
Torque: 0.5 Nm
Figure A2: CFW300-IODRB dimentions in mm [in]
Figura A2: Dimensiones del CFW300-IODRB en mm [in]
Figura A2: Dimensões do CFW300-IODRB em mm [in]
Preto
Vermelho
Branco
RS232
Motor
Sensor
Hall
(F)
(N)
(**)
13 14 15 16 17 18 19 20
Figure A3: Signals on the IO expansion connector
Figura A3: Señales en el conector de expansión de IOs
Figura A3: Sinais no conector de expansão de IO’s
Document: 10004616595 / 00
WEG Drives & Controls - Automação LTDA.
Jaraguá do Sul - SC - Brazil
Phone 55 (47) 3276-4000 - Fax 55 (47) 3276-4020
São Paulo - SP - Brazil
Phone 55 (11) 5053-2300 - Fax 55 (11) 5052-4212
automacao@weg.net
www.weg.net
1 SAFETY INFORMATION
1.1 SAFETY WARNINGS
NOTE!
Only use the I/O expansion module (CFW300-IODRB) on WEG
CFW300-2 inverters.
It is recommended to read the CFW300-2 user manual before
installing or operating this accessory.
This guide contains important information regarding the proper
understanding and correct operation of this module.
1.2 PRELIMINARY RECOMMENDATIONS
ATTENTION!
Always disconnect the general power supply before connecting
or disconnecting the accessories of the CFW300-2 fitness drive
frequency inverter.
Wait for at least 10 minutes for the full discharge of the inverter.
2 GENERAL INFORMATION
This guide provides directions for the installation, configuration and
operation of the I/O expansion module (CFW300-IODRB).
3 CONTENT OF THE PACKAGE
Upon receiving the product, check if the package contains:
Accessory in anti-static package.
Installation, configuration and operation guide.
4 INSTALLATION OF THE ACCESSORY
The CFW300-IODRB is easily connected to the CFW300-2 fitness drive
frequency inverter by means of the plug-and-play concept. The procedures
below must be observed for the proper installation and start-up:
1. With the inverter de-energized, remove the cover of the IO expansion
accessory and the protection cover of the connection of the inverter IO
expansion accessory (XC4) (Figure A1).
2. Fit the accessory to be installed as shown in Figure A1.
3. Power up the inverter.
5 CONFIGURATIONS
The CFW300-IODR connections must be done to the I/O expansion
connector as per Table 1. The Accessory connector pins are shown in
Figure A2. The Figure A3 shows connection examples of digital inputs.
Table 1: Signals of the I/O expansion connector
Connector Description
13 Tx Transmission of the serial communication RS232
14 Rx Receipt of the serial communication RS232
15 GND Reference (0 V) for Hall Sensor (white wire)
16 HALL Signal of Hall Sensor (red wire)
17 +5 V +5 Vdc of the Hall Sensor (black wire)
18 C Common of the relay outputs
19 DO2 Relay output (On/Off)
(*)
Maximum voltage: 250 Vac
Maximum current: 5 A
20 DO3 Relay output (Forward/Reverse)
(*)
Maximum voltage: 250 Vac
Maximum current: 5 A
(*) The available relay outputs are NO.
(**) Circuit breaker to be defined.
NOTE!
The software version of the CFW300-IODRB can be viewed in
parameter P024 of the CFW300-2 inverter.
1 INFORMACIONES DE SEGURIDAD
1.1 AVISOS DE SEGURIDAD
¡NOTA!
Solamente utilizar el módulo de expansn de I/O (CFW300-IODRB)
en los convertidores WEG serie CFW300-2.
Se recomienda la lectura del manual del usuario del CFW300 -2
antes de instalar o operar este accesorio.
El contenido de esta guía suministra informaciones importantes
para el correcto entendimiento y el buen funcionamiento de
este módulo.
1.2 RECOMENDACIONES PRELIMINARES
¡ATENCIÓN!
Siempre desconecte la alimentación general antes de conectar
o desconectar los accesorios del convertidor de frecuencia
fitness drive CFW300-2.
Aguarde por lo menos 10 minutos para garantizar la
desenergización completa del convertidor.
2 INFORMACIONES GENERALES
Esta guía orienta para la instalación, configuración y operación del módulo
de expansión de I/O (CFW300-IODRB).
3 CONTENIDO DEL EMBALAJE
Al recibir el producto, verificar si el embalaje contiene:
Accesorio en embalaje antiestático.
Guía de instalación, configuración y operación.
4 INSTALACIÓN DEL ACCESORIO
El CFW300-IODRB es fácilmente conectado al convertidor de frecuencia
fitness drive CFW300-2 utilizando el concepto "plug-and-play". Los
procedimientos de abajo deberán ser seguidos para la correcta instalacn
y puesta en funcionamiento:
1. Con el convertidor sin tensión, retire la tapa de los accesorios de
expansión de IOs y la tapa de protección de la conexn de los
accesorios de expansión de IOs (XC4) del convertidor (Figura A1).
2. Encastre el accesorio a ser instalado, conforme es indicado en la
Figura A1.
3. Energice el convertidor.
5 CONFIGURACIONES
Las conexiones del accesorio CFW300-IODRB deben ser hechas en el conector
de expansión de I/O conforme la Tabla 1. Los terminales del conector del
accesorio son presentados en la Figura A2. La Figura A3 presenta ejemplos de
conexión de las entradas digitales.
Tabla 1: Señales del conector de expansión de I/O
Conector Descripción
13 Tx Transmisión de la comunicación serial RS232
14 Rx Recepción de la comunicación serial RS232
15 GND Referencia (0 V) para Sensor Hall (cable blanco)
16 HALL Señal del Sensor Hall (cable rojo)
17 +5 V +5 Vcc del Sensor Hall (cable negro)
18 C Común de las salidas a re
19 DO2 Salida a relé (Enciende/Apaga)
(*)
Tensión máxima: 250 Vca
Corriente máxima: 5 A
20 DO3 Salida a relé (Horario/Antihorario)
(*)
Tensión máxima: 250 Vca
Corriente máxima: 5 A
(*) Las salidas a relé disponibles son de tipo NA.
(**) Disyuntor a ser definido.
¡NOTA!
La versn de software del accesorio CFW300-IODRB puede
ser visualizada en el parámetro P024 del convertidor CFW300-2.