Automation Direct IOAENC Guía del usuario

Tipo
Guía del usuario
I/O Expansion Module and Encoder Input
Módulo de Expansión de I/O y Entrada de
Encoder
Módulo de Expansão de I/O e Entrada de
Encoder
CFW300-IOAENC
Installation, Configuration and Operation Guide
Guía de Instalación, Configuración y Operación
Guia de Instalação, Configuração e Operação
Motors | Automation | Energy | Transmission & Distribution | Coatings
WEG Drives & Controls - Automação LTDA.
Jaraguá do Sul - SC - Brazil
Phone 55 (47) 3276-4000 - Fax 55 (47) 3276-4020
São Paulo - SP - Brazil
Phone 55 (11) 5053-2300 - Fax 55 (11) 5052-4212
automacao@weg.net
www.weg.net
1 INFORMAÇÕES DE SEGURANÇA
1.1 AVISOS DE SEGURANÇA
NOTA!
Somente utilizar o módulo de expansão de I/O e entrada de encoder
(CFW300-IOAENC) nos inversores WEG série CFW300.
Recomenda-se a leitura do manual do usuário do CFW300 antes
de instalar ou operar esse acessório.
O conteúdo deste guia fornece informações importantes para o
correto entendimento e bom funcionamento deste módulo.
1.2 RECOMENDAÇÕES PRELIMINARES
ATENÇÃO!
Sempre desconecte a alimentação geral antes de conectar ou
desconectar os acessórios do inversor de frequência CFW300.
Aguarde pelo menos 10 minutos para garantir a desenergização
completa do inversor.
Este acessório não é destinado para o uso em aplicões que
exijam controle vetorial.
2 INFORMAÇÕES GERAIS
Este guia orienta na instalação, configuração e operação do módulo de expansão
de I/O e entrada de Encoder (CFW300-IOAENC).
O CFW300-IOAENC tem dois canais diferenciais "A" e "B" para leitura dos sinais
de um encoder incremental com frequência de até 400 kHz.
3 CONTEÚDO DA EMBALAGEM
Ao receber o produto, verificar se a embalagem contém:
Acessório em embalagem anti-estática.
Guia de instalação, configuração e operação.
4 INSTALAÇÃO DO ACESRIO
O CFW300-IOAENC é facilmente conectado ao inversor de freqncia CFW300
utilizando o conceito “plug-and-play”. Os procedimentos abaixo devem ser seguidos
para a correta instalação e colocação em funcionamento:
1. Com o inversor desenergizado, retire a tampa de acessórios de expansão de
IO's e a tampa de proteção da conexão dos acessórios de expansão de IO's
(XC4) do inversor (Figura A1).
2. Encaixe o acessório a ser instalado conforme indicado na Figura A1.
3. Energize o inversor.
5 CONFIGURAÇÕES
As conexões do acessório CFW300-IOAENC devem ser feitas no conector de
expansão de I/O conforme Tabela 1. Os pinos do conector do acessório são
apresentados na Figura A2. A Figura A3 apresenta um exemplo de conexão da
entrada e saída analógica e um encoder incremental em quadratura.
Tabela 1: Sinais do conector de expansão de I/O
Conector Descrição Especificações
13 AI2 Entrada analógica 2
(teno)
Entrada isolada em tensão, nível
0 a 10 Vcc
Resolução: 10 bits
Impedância: 100 kΩ
Funções programáveis
Tensão máxima admitida: 30 Vcc
14 GND Referência 0 V
Não interligado com o PE.
15 AI2 Entrada analógica 2
(corrente)
Entrada isolada em corrente, nível 0
a 20 mA ou 4 a 20 mA
Resolução: 10 bits
Impedância: 500 Ω
Funções programáveis
Tensão máxima admitida: 30 Vcc
16 +10 V Referência +10 V
para potenciômetro
Fonte de tensão: +10 Vcc
Capacidade máxima: 50 mA
Tolerância: ±5 %
17 AO1 Saída analógica 1
Saída isolada, níveis: 0 a 10 V ou 0 a
20 mA ou 4 a 20 mA
Funções programáveis
RL ≥ 10 kΩ (0 a 10 V) ou RL ≤ 500 Ω
(0 a 20 mA / 4 a 20 mA)
18 AO2 Saída analógica 2
19 GND Referência 0 V
Não interligado com o PE
20 A Entrada em
quadratura A
Frequência máxima: 400kHz
21
A
Entrada em
quadratura A
invertida
22 B Entrada em
quadratura B
23
B
Entrada em
quadratura B
invertida
24 + 5 V Referência para
alimentação do
encoder +5 V
Fonte de tensão: + 5 Vcc
Capacidade máxima: 100 mA
Tolerância: ±5%
Para utilizar a entrada analógica do módulo com sinal em tensão deve-se usar
o pino 13 do conector de expansão de I/O. Para sinal em corrente dispõe-se do
pino 15 do mesmo conector. Deve-se, ainda, ajustar os parâmetros relacionados
conforme Tab ela 2.
Tabela 2: Configurações de parâmetro e conectores para seleção do tipo de sinal na
entrada analógica no CFW300-IOAENC
Entrada Sinal Conector Faixa do Sinal
Ajuste de
Parâmetros
AI2 Tensión 13 0 ... 10 V P236 = 0 o 2
Corriente 15 0 ... 20 mA P236 = 0 o 2
4 ... 20 mA P236 = 1 o 3
A seleção dos tipos de saídas anagicas é realizada automaticamente quando se
configuram os parâmetros P253 e P256. Para saída em tensão deve-se configurar
P253 = 0 ou 3 (AO1) e/ou P256 = 0 ou 3 (AO2), para uma saída analógica em corrente
altera-se P253 = 1, 2, 4 ou 5 (AO1) e/ou P256 = 1, 2, 4 ou 5 (AO2), de acordo com a
amplitude desejada para o sinal. A Tabela 3 apresenta a configuração necesria
para cada tipo de sinal de saída. Para mais detalhes consulte o capítulo 12 do
manual de programação do CFW300.
Tabela 3: Configuração de parâmetro para seleção do tipo de sinal nas saídas
analógicas no CFW300-IOAENC
Entrada Sinal Faixa do Sinal
Ajuste de
Parâmetros
AO1 Tensão 0 ... 10 V P253 = 0 ou 3
Corrente 0 ... 20 mA P253 = 1 ou 4
4 ... 20 mA P253 = 2 ou 5
AO2 Tensão 0 ... 10 V P256 = 0 ou 3
Corrente 0 ... 20 mA P256 = 1 ou 4
4 ... 20 mA P256 = 2 ou 5
NOTA!
A vero de software do acessório CFW300-IOAENC pode ser
visualizada no parâmetro P024 do inversor CFW300.
PortuguêsAPPENDIX A - FIGURES
ANEXO A - FIGURAS
(a) Removal of the accessory and connection protection covers (XC4) from the IO expansion
(a) Remoción de las tapas de accesorios y de protección de la conexión (XC4) de la expansión
de Is
(a) Remoção das tampas de acessórios e de protão da conexão (XC4) da expansão de IO's
(b) Accessory connection
(b) Conexión del accesorio
(b) Conexão do acessório
Figure A1: (a) to (b) Installation of accessory
Figura A1: (a) a (b) Instalación de accesorio
Figura A1: (a) a (b) Instalação de acessório
20.6
[0.81]
64 [2.52]
46.8
[1.84]
I/O expansion connector
Conector de expansión de I/O
Conector de expansão de I/O
Figure A2: CFW300-IOAENC dimensions in mm [in] and connectors location
Figura A2: Dimensiones del CFW300-IOAENC en mm [in] y localización de los conectadores
Figura A2: Dimensões do CFW300-IOAENC em mm [in] e localização dos conectores
Incremental encoder
Encoder incremental
Figure A3: Example of connection of the analog input and output and an incremental encoder
in quadrature
Figura A3: Ejemplo de conexión de entrada y salida analógicas y un encoder incremental en
cuadratura
Figura A3: Exemplo de conexão de entrada e saída analógica e encoder incremental em
quadratura
Document: 10003711897 / 00
13324404
English
Español1 SAFETY INFORMATION
1.1 SAFETY WARNINGS
NOTE!
Only use the I/O expansion module and encoder input
(CFW300-IOAENC) on WEG CFW300 series inverters.
It is recommended to read the CFW300 user manual before installing
or operating this accessory.
This guide contains important information regarding the proper
understanding and correct operation of this module.
1.2 PRELIMINARY RECOMMENDATIONS
ATTENTION!
Always disconnect the general power supply before connecting or
disconnecting the accessories of the CFW300 frequency inverter.
Wait for at least 10 minutes for the full discharge of the power
capacitors.
This accessory is not destined for use in applications requiring a
control vector.
2 GENERAL INFORMATION
This guide provides directions for the installation, configuration and operation of
the I/O expansion module and Encoder input (CFW300-IOAENC).
The CFW300-IOAENC has two differential channels "A" and "B" for reading signals
from an incremental encoder with frequency up to 400 kHz.
3 CONTENT OF THE PACKAGE
Upon receiving the product, check if the package contains:
Accessory in anti-static package.
Installation, configuration and operation guide.
4 INSTALLATION OF THE ACCESSORY
The CFW300-IOAENC is easily connected to the CFW300 frequency inverter by
means of the plug-and-play concept. The procedures below must be observed
for the proper installation and start-up:
1. With the inverter de-energized, remove the cover of the IO expansion accessory
and the protection cover of the connection of the inverter IO expansion
accessory (XC4) (Figure A1).
2. Fit the accessory to be installed as shown in Figure A1.
3. Power up the inverter.
5 CONFIGURATIONS
The CFW300-IOAENC connections must be done to the I/O expansion connector
as per Table 1. The accessory connector pins are shown in Figure A2. Figure A3
shows an example of connection of the analog input and output and an incremental
encoder in quadrature.
Table 1: Signals of the I/O expansion connector
Connector Description Specifications
13 AI2 Analog input 2
(voltage)
Voltage isolated input, level 0 to 10 Vdc
Resolution: 10 bits
Impedance: 100 kΩ
Programmable functions
Maximum accepted voltage: 30 Vdc
14 GND Reference 0 V
Not interconnected with PE
15 AI2 Analog input 2
(current)
Current isolated input, level 0 to 20 mA
or 4 to 20 mA
Resolution: 10 bits
Impedance: 500 Ω
Programmable functions
Maximum accepted voltage: 30 Vdc
16 +10 V Potentiometer
reference +10 V
Power supply: +10 Vdc
Maximum capacity: 50 mA
Tolerance: ±5 %
17 AO1 Analog output 1
Isolated output, levels: 0 to 10 V or 0 to
20 mA or 4 to 20 mA
Programmable functions
R
L
≥ 10 kΩ (0 to 10 V) or R
L
≤ 500 Ω (0
to 20 mA / 4 a 20 mA)
18 AO2 Analog output 2
19 GND Reference 0 V
Not interconnected with PE
20 A Quadrature input A
Maximum frequency: 400kHz
21
A
Quadrature input A
inverted
22 B Quadrature input B
23
B
Quadrature input A
inverted
24 + 5 V Encoder reference
+5 V
Power supply: + 5 Vdc
Maximum capacity: 100 mA
Tolerance: ±5%
In order to use the module analog input with voltage signal, pin 13 of the I/O
expansion connector must be used. For current signal, pin 15 of the same connector
is available. The related parameters must also be set as per Table 2.
Table 2: Configurations of paremeter and connectors to select the type of analog input
signal on the CFW300-IOAENC
Input Signal Connector Signal Range Parameter Setting
AI2 Voltage 13 0 ... 10 V P236 = 0 or 2
Current 15 0 ... 20 mA P236 = 0 or 2
4 ... 20 mA P236 = 1 or 3
The selection of the analog outputs types is performed automatically when
parameters P253 and P256 are configured. For voltage output, you must configure
P253 = 0 or 3 (AO1) and/or P256 = 0 or 3 (AO2); for a current analog output, you
change P253 = 1, 2, 4 or 5 and/or P256 = 1, 2, 4 or 5 (AO2), according to the
desired amplitude for the signal. Table 3 presents the necessary configuration for
each type of output signal. For further details, refer to chapter 12 of the CFW300
programming manual.
Table 3: Configuration of paremeter to select the types of analog outputs signal on the
CFW300-IOAENC
Output Signal Signal Range Parameter Setting
AO1 Voltage 0 ... 10 V P253 = 0 or 3
Current 0 ... 20 mA P253 = 1 or 4
4 ... 20 mA P253 = 2 or 5
AO2 Voltage 0 ... 10 V P256 = 0 or 3
Current 0 ... 20 mA P256 = 1 or 4
4 ... 20 mA P256 = 2 or 5
NOTE!
The software version of the CFW300-IOAENC accessory can be viewed
in parameter P024 of the CFW300 inverter.
1 INFORMACIONES DE SEGURIDAD
1.1 AVISOS DE SEGURIDAD
¡NOTA!
Solamente utilizar el módulo de expansión de I/O y entrada de encoder
(CFW300-IOAENC) en los convertidores WEG serie CFW300.
Se recomienda la lectura del manual del usuario del CFW300 antes
de instalar o operar este accesorio.
El contenido de esta guía se proporciona información importante para
el correcto entendimiento y buen funcionamiento de este módulo.
1.2 RECOMENDACIONES PRELIMINARES
¡ATENCIÓN!
Siempre desconecte la alimentación general antes de conectar o
desconectar los accesorios del convertidor de frecuencia CFW300.
Espere al menos 10 minutos para garantizar la desenergización
completa del convertidor.
Este accesorio no está destinado para uso en aplicaciones que
exigen control vectorial.
2 INFORMACIONES GENERALES
Esta guía orienta en la instalación, configuración y operación del módulo de
expansn de I/O y entrada de Encoder (CFW300-IOAENC).
El CFW300-IOAENC tiene dos canales diferenciales "A" y "B" para los sales de
lectura de un encoder incremental con una frecuencia de hasta 400 kHz.
3 CONTENIDO DEL EMBALAJE
Al recibir el producto, verificar si el embalaje contiene:
Accesorio en embalaje anti-estático.
Guía de instalación, configuración y operación.
4 INSTALACIÓN DEL ACCESORIO
El CFW300-IOAENC es fácilmente conectado al convertidor de frecuencia CFW300
utilizando el concepto “plug and play”. Deben ser seguidos los procedimientos de
abajo, para la correcta instalación y puesta en funcionamiento:
1. Con el convertidor sin tensión, retire la tapa de los accesorios de expansn
de IOs y la tapa de proteccn de la conexión de los accesorios de expansión
de IOs (XC4) del convertidor (Figura A1).
2. Encaje el accesorio a ser instalado, conforme es indicado en la Figura A1.
3. Energice el convertidor.
5 CONFIGURACIONES
Las conexiones del accesorio CFW300-IOAENC deben ser hechas en el conector
de expansión de I/O, conforme la Tabla 1. Los terminales del conector de accesorios
están presentados en la Figura A2. La Figura A3 presenta un ejemplo de conexión
de entrada y salida analógicas y un encoder incremental en cuadratura.
Tabla 1: Señales del conector de expansión de I/O
Conector
Descripción
Especificaciones
13 AI2 Entrada analógica
2 (tensión)
Entrada aislada en tensión, nivel
0 a 10 Vcc
Resolución: 10 bits
Impedancia: 100 kΩ
Funciones programables
Tensión máxima admitida: 30 Vcc
14 GND Referencia 0 V
No interconectado con PE
15 AI2 Entrada analógica
2 (corriente)
Entrada aislada en corriente, nivel 0
a 20 mA o 4 a 20 mA
Resolución: 10 bits
Impedancia: 500 Ω
Funciones programables
Tensión máxima admitida: 30 Vcc
16 +10 V Referencia +10 V
para potenciómetro
Fuente de tensión: +10 Vcc
Capacidad máxima: 50 mA
Tolerancia: ±5 %
17 AO1 Analog output 1
Salida aislada, niveles: 0 a 10 V o 0 a
20 mA o 4 a 20 mA
Funciones programables
RL ≥ 10 kΩ (0 a 10 V) o RL ≤ 500 Ω
(0 a 20 mA / 4 a 20 mA)
18 AO2 Analog output 2
19 GND Referencia 0 V
No interconectado con PE
20 A Entrada en
cuadratura A
Frecuencia máxima: 400kHz
21
A
Entrada en
cuadratura A
invertida
22 B Entrada en
cuadratura B
23
B
Entrada en
cuadratura B
invertida
24 + 5 V Fuente para
alimentación del
encoder 5 Vcc
Fuente de tensión: + 5 Vdc
Capacidad máxima: 100 mA
Tolerancia: ±5%
Para utilizar la entrada anagica del módulo con señal en tensión se debe usar
el terminal 13 del conector de expansn de I/O. Para señal en corriente se utiliza
el terminal 15 del mismo conector. Se debe, también, ajustar los pametros
relacionados, conforme lo muestra la Tabla 2.
Tabla 2: Configuraciones de pametro y conectores para selección del tipo de señal
en la entrada analógica del CFW300-IOAENC
Entrada Señal Conector
Rango de la
Señal
Ajuste de
Parámetros
AI2 Tensión 13 0 ... 10 V P236 = 0 o 2
Corriente 15 0 ... 20 mA P236 = 0 o 2
4 ... 20 mA P236 = 1 o 3
La seleccn de los tipos de salidas analógicas es realizada automáticamente
cuando se configura los parámetros P253 y P256. Para salida en tensión se debe
configurar P253 = 0 o 3 (AO1) y/o P256 = 0 o 3 (AO2), para una salida analógica
en corriente se altera P253 = 1, 2, 4 o 5 (AO1) y/o P256 = 1, 2, 4 o 5 (AO2), de
acuerdo con la amplitud deseada para la sal. La Tabla 3 presenta la configuración
necesaria para cada tipo de señal de salida. Para más detalles consulte el capítulo
12 del manual de programación del CFW300.
Tabla 3: Configuración de parámetro para selección del tipo de señal en las salidas
analógicas del CFW300-IOAENC
Salida Señal
Rango de la
Señal
Ajuste de
Parámetros
AO1 Tensión 0 ... 10 V P253 = 0 o 3
Corriente 0 ... 20 mA P253 = 1 o 4
4 ... 20 mA P253 = 2 o 5
AO2 Tensión 0 ... 10 V P256 = 0 o 3
Corriente 0 ... 20 mA P256 = 1 o 4
4 ... 20 mA P256 = 2 o 5
¡NOTA!
La versn de software del accesorio CFW300-IOAENC puede ser
visualizada en el parámetro P024 del convertidor CFW300.