Simpson Strong-Tie FPBB44 Guía de instalación

Tipo
Guía de instalación
Installer’s
Pocket Guide
Guía de Bolsillo
Para el Instalador
S-C-INSTALL19
22
Index/Indice
Concrete Connectors and
Anchors
BPS-LBPS ...........................13
FWANZ .................................14
MAB ............................... 15–17
MASA ............................. 18–21
SB ........................................22
SSTB ....................................23
URFP ...................................24
Holdowns and Tension Ties
HD ........................................25
HDQ8 ...................................26
HDU ..................................... 27
HTT ...................................... 28
LSTHD/STHD .......................29
Bases and Caps
ABA ......................................30
ABU ............................... 31–33
ABW .....................................34
BC ........................................35
BCS2-2 /4 .............................36
BC40 ....................................37
CB .................................. 38–39
CBSQ ...................................40
CC .......................................41
CCQ .....................................42
CPTZ ....................................43
LCE4 .................................... 44
PB ........................................45
PCZ/EPCZ ...........................46
PPBZ ....................................47
RPBZ ...................................48
Solid Sawn Joist Hangers
HUS .....................................49
LSSJ ....................................50
LRU ......................................51
LSSR .............................. 52–53
LUCZ ....................................54
LUS ................................ 56–57
SUR/L ............................ 58–59
VPA ................................ 60–61
Engineered Wood and
Structural Composite
Lumber Connectors
ITS ................................. 62–63
IUS ................................. 64–65
Plated Truss Connectors
DTC ......................................66
STC ......................................67
HTU ......................................68
TSBR ...................................69
THA ................................ 70–71
THJA .................................... 72
THJU ....................................73
Masonry Connectors
HETA/META ................... 74–75
LGT ................................ 76–77
VGT ................................ 78–79
Straps and Ties
A35 ......................................80
CSHP ................................... 81
CS/CMST14 ................... 82–83
H1 .................................. 84–85
H2.5A ...................................86
H2.5T ................................... 87
H10A .............................. 88–89
LS ........................................90
LSTA ....................................91
LTP4/LTP5 ...........................92
RBC .....................................93
MST ............................... 94–95
RSP ......................................96
SP ........................................ 97
SSP ......................................98
TSP ...................................... 99
Deck Connectors
DTT1Z ................................ 100
DTT2Z ................................ 101
Miscellaneous
HSS ...................................102
PSPN .................................103
TWB ........................... 104–105
Anchoring and Fastening
Systems for Concrete and
Masonry
Adhesive Anchoring .... 106–107
Titen HD
®
...........................108
Fastening Systems
Strong-Drive
®
SDWC
Truss Screw ........................109
Strong-Drive
®
SDWF
Floor-to-Floor Screw ... 110–111
33
Connectors: Types of Nail Holes
Conectores: Tipos de Agujeros de Clavo
Round
Redondo
Purpose:
To fasten a connector.
Fill Requirements:
Always fill, unless
otherwise noted.
Propósito:
Para fijar un conector.
Requisitos para Llenar:
Llénelo siempre, salvo que
se indique lo contrario.
Triangular
Purpose:
To increase a connector’s
strength or to achieve
maximum strength.
Fill Requirements:
When the Designer
specifies max. nailing.
Propósito:
Para aumentar la fuerza
de un conector o para
lograr una fuerza máxima.
Requisitos para Llenar:
Llénelo cuando el
diseñador lo especifica
clavado “Máx.”
Hexagonal
Hexágono
Purpose:
To fasten a connector to
concrete or masonry.
Fill Requirements:
Always fill when fastening
a connector to concrete or
fastening a connector
with masonry screws.
Propósito:
Para fijar un conector a
concreto o mampostería.
Requisitos para Llenar:
Siempre llénelo al fijar un
conector a concreto o
al fijar un conector con
tornillos de mampostería.
Obround
Alargado
Purpose:
To make fastening a
connector in a tight
location easier.
Fill Requirements:
Always fill, unless
otherwise noted.
Propósito:
Para fijar un conector en
una locación apretada con
el fin de facilitar el trabajo.
Requisitos para Llenar:
Llénelo siempre, salvo que
se indique lo contrario.
Diamond
Diamante
Purpose:
To temporarily fasten a
connector to make
installing it easier.
Fill Requirements:
None.
Propósito:
Para fijar temporalmente
un conector, con el
propósito de facilitar su
instalación.
Requisitos para Llenar:
Ninguno.
44
Purpose:
Installed into the joist and header, to distribute
the load through two points on each joist nail
for greater strength. Must use full-length nail
unless 2
½
” nail approved by Designer.
Fill Requirements:
Always fill.
Propósito:
Instalado en la vigueta y la cabecera, para
distribuir la carga a través de dos puntos en
cada clavo de vigueta para mayor resistencia.
Debe usar un clavo de largo completo a
menos que un clavo de 2
½
” esté aprobado
por el diseñador.
Requisitos para Llenar:
Llénelo siempre.
Purpose:
To temporarily position and secure
the connector for easier and faster
installation.
Fill Requirements:
None.
Propósito:
Se usan para colocar el conector y
fijarlo temporalmente, con el fin de
facilitar y hacer más rápida su
instalación.
Requisitos para Llenar:
Ninguno.
Double-Shear
Nailing
Clavado
de Doble
Penetración
Speed Prongs
Dientes Rápidos
Connectors: Types of Nail Holes
Conectores: Tipos de Agujeros de Clavo
DO NOT use short
(1
½
") nails for
double-shear nailing.
NO usen los clavos
cortos de 1
½
" para uso
de doble penetración.
55
Dome Nailing
Clavado
con Cúpula
Purpose:
To guide the nail into the joist and header
at a 45° angle.
Fill Requirements:
Always fill.
Propósito:
Con este dispositivo se guían el clavo
en lavigueta y la viga cabezal en ángulo
de 45°.
Requisitos para Llenar:
Llénelo siempre.
Purpose:
To use when wood splitting may occur,
and to speed installation.
Fill Requirements:
Always fill.
Propósito:
Se usa cuando la madera puede rajarse
oabrirse y con el propósito hacer más
rápida la instalación.
Requisitos para Llenar:
Llénelo siempre.
Positive-Angle
Nailing
Clavado
Efectivo
en Ángulo
Connectors: Types of Nail Holes
Conectores: Tipos de Agujeros de Clavo
QUESTIONS?
¿PREGUNTAS?
(
800
)
999-5099 or visit strongtie.com
The information in this guide shows contractors how our Simpson Strong-Tie
®
products should be correctly installed. It is not intended for use by Designers.
It is important that users of this guide also follow any installation guidelines
specified by the Designer and refer to the current Simpson Strong-Tie Wood
Construction Connectors catalog for other crucial installation information.
Esta guía tiene como objetivo servir como herramienta de referencia rápida
para facilitar la correcta instalación de los productos Simpson Strong-Tie
®
. Es
importante que los usuarios sigan todas las pautas de instalación especificadas
por el diseñador y consulten el catálogo de Conectores para Construcciones
de Madera de Simpson Strong-Tie para obtener más información importante
sobre la instalación.
66
Fasteners/Clavos
3x wood
nailers.
NOT for
double-shear
nailing unless
approved by
Designer.
Para madera
de 3". NO
para clavado
de double
penetración
salvo que así
lo apruebe el
diseñador.
Straps, heavy
hangers,
plated
truss and SCL
connectors.
Cintas, soporte
de viga
pesadas,
para cerchas
y madera
composito.
0.162" x 3
½
"
(16d common)
0.162" x 2
½
"
(N16)
0.148" x 3
¼
"
(16d sinker)
0.148" x 3"
(10d common)
Straps,
hangers,
header
fastening.
Cintas,
soporte
de viga.
Straps,
hangers,
header
fastening.
Cintas,
soporte
de viga.
Same
uses
Mismo
uso
"
"
"
"
"
"
"
"
"
77
Collated
3x wood
nailers.
NOT for
double-shear
nailing unless
approved by
Designer.
Para madera
de 3". NO
para clavado
de double
penetración
salvo que así
lo apruebe el
diseñador.
0.148" x 1
½
"
(N10)
0.131" x 2
½
"
(8d common)
0.148" x 2
½
" 0.131" x 1
½
"
(N8)
2x joist nailing.
Caution: Load
reduction
if used as
header
nails.
Galvanized
nail shown.
Clavado de
vigas 2x.
Cuidado:
Reduce la
capacidad
si se usa en la
viga cabezal.
Se muestra un
clavo
galvanizado.
Light-duty
framing
anchors
and some
rafter ties.
Galvanized
nail shown.
Conectores
ligeros y
“clips” de
huracán.
Se muestra
un clavo
galvanizado.
Rafter ties.
“Clips” de
huracán.
When using stainless-steel connectors, use ring-shank
stainless-steel nails of the same size. When using ZMAX
®
/
hot-dip galvanized connectors, use fasteners galvanized
per ASTM A153.
Cuando use conectores de acero inoxidable, use clavos de acero
inoxidable de vástago de anillo del mismo tamaño. Cuando use
conectores galvanizados por inmersión en caliente/ZMAX
®
, use
sujetadores galvanizados según ASTMA153.
Fasteners/Clavos
"
"
"
"
"
"
"
"
"
88
Fasteners/Clavos
Power-driven collated nails can be
used only if:
1. Correct diameter and length
2. Correct quantity is installed
3. The power tool has a hole
location feature (finds the hole)
4. Nails are not overdriven
Do Not Overdrive Nails.
Do Not Drive Nails
Through Connectors.
No Se Mete
Demasiado.
No Se Puede.
Hacer Agujeros
Con Maquina.
Common screws, such as
wood and drywall screws,
may NOT be used to replace
NAILS in connectors.
NO se puede usar tornillos
comunes, tales como tornillos
para madera y panel yeso, en
vez de CLAVOS en conectores.
S6
Sólo se pueden utilizar clavos
estructurales para pistola si:
1. Diámetro y largo correctos
2. La cantidad correcta está instalada
3. La herramienta eléctrica tiene una
función de ubicación de orificio
(encuentra el orificio)
4. Los clavos no están demasiado
ajustados
Strong-Drive SD Connector screws are designed to replace
nails in many popular Simpson Strong-Tie connectors. See
strongtie.com/sd for information.
Los tornillos para conectores SD Strong-Drive están diseñados para
reemplazar los clavos en los conectores de Simpson Strong-Tie más
populares. Consulte strongtie.com/sd para obtener más información.
99
Some connectors install with the
¼
" Strong-Drive
®
SDS Heavy-Duty
Connector screw
1. Install with
" hex socket or
nut driver
2. Predrilling generally not required
3. Do not substitute with lag screws
Algunos conectores se instalan con
el ¼" Strong-Drive
®
SDS Heavy-Duty
Connector screw.
Bolt
Diameter:
½"
,
"
,
¾"
,
"
, 1
"
Pernos
Diametro:
½"
,
"
,
¾"
,
"
, 1
"
1. Instalar con un destornillador de casquillo
hexagonal o de tuercas de
"
2. Generalmente no es necesario efectuar
perforaciones previas
3. No sustituir con tirafondos
Fasteners/Clavos
Titen
®
2 Hex-Head Masonry Screw
Diameter:
⁄"
,
¼"
Tornillo Para Mampostería
Diametro:
⁄"
,
¼"
1010
General Connector Installation
Instalación de Conectores en General
Wood Nailers
Listones Clavadores De Madera
Correct attachment
Montaje correcto
Nailer too wide
Listón clavador muy ancho
Nailer too narrow
Listón clavador muy estrecho
Top Flange Hangers
Soportes Con Ala Superior
Hanger over-spread
Soporte demasiado
abierto
Hanger not plumb
Soporte fuera de
plomo
Flush Framing
Nailer too thin or wrong
hanger for the application
Clavadora demasiado delgada
o soporte incorrecto para
laaplicación
1111
Toenailing/Clavado En Diagonal
Do not toenail I-joists before installing
top flange or face-mount hangers
No clave en ángulo las viguetas ‘I’ antes
de montar los soportes (con o sin ala
superior)
Positive-Angle Nailing
Clavado Efectivo En Ángulo
Correct nailing
approx. 45° angle
Clavado correcto
aproximadamente
a 45°
Nail at wrong angle
Clavado con un
ángulo incorrecto
Nail too long
Clavos demasiado
largos
Prevent Rotation/Evitar La Rotación
General Connector Installation
Instalación de Conectores en General
Rotation Prevented by
Hanger Height
(web stiffeners required)
60% of
D min.
D
No Rotation Resistance
Rotation Prevented by
Lateral Support
(clips or blocking)
Less than
60% of D
Rotation Prevented by
Lateral Flange Support
1212
General Connector Installation
Instalación de Conectores en General
Double-Shear Nailing
Clavado De Doble Penetración
Shorter nails may not be used
as double-shear nails.
No se pueden utilizar clavos
más cortos como clavos de
doble penetración.
Must use full-length nail unless
2
½
" nail approved by Designer.
Debe usar un clavo de largo
completo a menos que un clavo de
2
½
" esté aprobado por el diseñador.
No gaps larger than
".
No hay espacios mayores a
".
1313
Concrete Connectors
and Anchors
BPS-LBPS
1
2
3
1414
FWANZ
1
2
0.148" x
1½
"
1515
3
/4"
MAB — Block/Bloque
0.148" x
1½
"
1
2
3
4
MAB
1616
MAB — Concrete/Concreto
1
2
3
4
1
2
3
4
5
MAB
1717
MAB — Concrete/Concreto
0.148" x
1½
"
6
7
MAB
1818
MASA
0.131" x
2½
"
0.148" x 3"
Forming
Encofrado
or
2
3
1
(2)
Duplex nails /
Clavo duplex
or/ó
(1) 0.148" x 3"
MASA
1919
0.148" x
1½
"
Connector
Conector
MASA
Reduced loads apply; check with Designer
before nailing over sheathing.
Se aplican cargas reducidas; consulte al
diseñador antes de clavar sobre el relleno.
Reduced loads apply;
check with Designer.
Se aplican cargas reducidas;
consulte al diseñador.
Blocking required attached to
sill with A35Z (not shown) or
per Designer.
Se debe adjuntar un
bloqueo al larguero con
A35Z (no se muestra) o
según indicaciones del
diseñador.
Alternative 1
Opción 1
Alternative 2
Opción 2
4
5
MASA
2020
MASA
Brick-Ledge Installation
Instalación Sobre Cornisa de Ladrillos
"
2x4 plate
1
2
3
(2) Duplex nails / Clavo duplex
MASA
2121
MASA
MASAP
similar
Inside-the-Mudsill Installation
Instalación en Solera
(2) Duplex nails / Clavo duplex
1
2
3
Embedment line
(top of concrete)
Línea de
empotramiento
(parte superior
del concreto)
MASA
2222
SB
Install a minimum 45°
from either edge.
Instalar a mínimo 45°
de cada cara.
24
24
24
AnchorMate
®
1
2
Embedment line
(top of concrete)
Línea de empotramiento
(parte superior del concreto)
34
450 450
SB
2323
Install a minimum 45°
from either edge.
Instalar a mínimo 45°
de cada cara.
SSTB
Install 45° from either edge.
Instalar 45° de cada cara.
34
450 450
Embedment line
(top of concrete)
Línea de empotramiento
(parte superior del concreto)
24
24
24
AnchorMate
®
1
2
Embedment line
(top of concrete)
Línea de empotramiento
(parte superior del concreto)
ABS Anchor Bolt
Stabilizer (optional)
SSTB
2424
URFP
S3
S3
S3
S3
S3
1
2
3
4
5
6
½
" x 4" Titen HD
®
. If using adhesive anchor, see pp. 106-107.
¼
" x 3" SDS Heavy-Duty Connector Screw (included)
Same installation for FRFP
FOR 1/2" SILL BOLT REPLACEMENT, FILL ROUND HOLES
FOR 5/8" SILL BOLT REPLACEMENT, FILL ALL HOLES
SIMPSON
Strong-Tie
®
S2.5
S2.5
S2.5
2525
Holdowns and
Tension Ties
HD
2
3
4
5
1
Model No./
N.º de
Modelo
Bolt Diameter/
Diámetro del
Perno Torneado
HD3B
"
HD5B
¾
"
HD7B
¾
"
HD9B
"
HD12 1"
HD19 1"
Bolts shall be
installed with the nut
and washer on the
opposite side of the
holdown.
Se deben instalar los
pernos con la tuerca
y la arandela en lado
opuesto del amarre.
Bolt holes must be
a minimum of
1
32
"
and a maximum
of
1
16
"
larger than
bolt diameter.
Los orificios para
los pernos deben
ser al menos
1
32
"
y
como máximo
1
16
"
más grandes que el
diámetro del perno.
2626
HDQ8
¼
" x 3" Strong-Drive
®
SDS HEAVY-DUTY CONNECTOR Screw
(included/incluida)
Square washer
required
(included).
Se requiere una
arandela cuadrada
(incluida).
1
2
3
Use
3
8
" driver.
Use un
destornillador
de
".
2727
HDU
Use
3
8
" driver.
Use un
destornillador
de
”.
¼
"
x 2
½
" Strong-Drive
®
SDS HEAVY-DUTY CONNECTOR Screw
(included/incluida)
1
2
3
2828
HTT
HTT4
HTT5
0.162" x 2
½
"
1
2
3
2929
LSTHD/STHD
Embedment line
(top of concrete)
Línea de empotramiento
(parte superior del
concreto)
StrapMate
®
Strap may be bent down
and back up one time only.
La abrazadera se puede
doblar hacia abajo y hacia
arriba sólo una vez.
1
2
16d Sinker
0.148" x 3
¼
"
3030
ABA
Bases and Caps
If using an adhesive
anchor, see pages
106–107 for
instructions.
Si utiliza un anclaje
adhesivo, consulte las
instrucciones de las
páginas 106–107.
0.148" x 3" — ABA44, ABA44R
0.162" x 3
½
" — ABA46, ABA46R, ABA66, ABA66R
1
2
3
4
3131
ABU — Nails/Clavos
If using an adhesive
anchor, see pages
106–107 for
instructions.
Si utiliza un anclaje
adhesivo, consulte las
instrucciones de las
páginas 106–107.
0.162" x 3
½
"
1
2
3
4
5
ABU
3232
ABU — Bolts/Pernos
If using an adhesive
anchor, see pages
106–107 for
instructions.
Si utiliza un anclaje
adhesivo, consulte las
instrucciones de las
páginas 106–107.
1
2
3
4
5
ABU
3333
ABU — Bolts/Pernos
Bolt Diameter:
½
"
Length:
ABU44/ABU46 = 4
½
"
ABU66 = 6
½
"
Bolt holes must be
a minimum of
1
32
"
and a maximum
of
1
16
"
larger than
bolt diameter.
Perno Torneado
Diámetro:
½
"
Largo:
ABU44/ABU46 = 4
½
"
ABU66 = 6
½
"
Los orificios para los
pernos deben ser al menos

"
y como máximo

"
más grandes que el diámetro
del perno.
6
7
8
ABU
3434
ABW
1
6
7
2
3
4
5
0.148" x 3"
ABW
3535
BC
0.162" x 3
½
"
1
2
3
4
BC
3636
B C S 2 - 2 / 4
0.148" x 3"
1
2
3
4
BCS2-2 /4
3737
BC40
0.162" x 3
½
"
1
2
3
3838
CB
Bolts/Pernos
3"
min.
3" min.
3" side
cover (min.)
Cubierta lateral
de 3" (mín.)
1
2
3
3" min. 3" min.
CB
3939
CB
3" side
cover (min.)
Cubierta lateral
de 3" (mín.)
Bolt holes must be
a minimum of

"
and a maximum of
⁄
" larger than bolt
diameter.
Los orificios para los
pernos deben ser al
menos

" y como máximo
⁄
" más grandes que el
diámetro del perno.
Bolt
Perno
Model
No. /
N.º de
Modelo
Bolt Size /
Tamaño
del Perno
CB44
" x 4
½
"
CB46
" x 4
½
"
CB48
" x 4
½
"
CB64
" x 6
½
"
CB66
" x 6
½
"
CB68
" x 6
½
"
CB86
¾
" x 8
½
"
CB88
¾
" x 8
½
"
CB1010
¾
" x 10
½
"
CB1012
¾
" x 10
½
"
CB1212
¾
" x 11
½
"
4
5
6
3" min.3" min.
4040
CBSQ
1
4
" x 2" Strong-Drive
®
SDS HEAVY-DUTY CONNECTOR Screw
Use
3
8
" driver.
Use un
destornillador
de
⁄
".
3"
min.
3" min.
1
2 3
4 5
CBSQ
4141
CC
Bolt holes must be a minimum
of

" and a maximum of
⁄
"
larger than bolt diameter.
Los orificios para los pernos
deben ser al menos

" y como
máximo
⁄
" más grandes que el
diámetro del perno.
Bolt
Perno
Beam or
Column Width
Ancho de Dintel o
de Columna
Bolt Size
Tamaño del Perno Torneado
Diameter
Diámetro
Length
Longitud
3
"
" 4
½
"
3
½
"
" 4
½
"
5
"
¾
" 6
½
"
5
½
"
" 6
½
"
6
¾
"
¾
" 8"
7"
¾
" 8"
7
½
"
¾
" 8
½
"
8
¾
"
¾
" 10"
9
½
"
¾
" 10
½
"
1
2
3
4
5
6
CC
4242
CCQ
Use
3
8
" driver.
Use un
destornillador
de
⁄
".
¼
" x 2
½
" Strong-Drive
®
SDS HEAVY-DUTY CONNECTOR Screw
1
2
3
4
CCQ
4343
CPTZ
1
2
3 4
5
6
8
9
7
10
If using an
adhesive
anchor, see
pages 106–107
for instructions.
Si utiliza un
anclaje adhesivo,
consulte las
instrucciones
de las páginas
106–107.
CPTZ
4444
LCE4
4x4
Beam
Viga
4x4
Post
Poste
1
2
3
0.162" x 3
½
"
LCE4
4545
PB
0.162" x 3
½
"
1
2
3
4 5
PB
4646
PCZ/EPCZ
1
2
3
4
1
2
3 4
0.148" x 3"
PCZ/EPCZ
4747
PPBZ
1" min.
6" min.
1" min.
1
2
3 4
6
5
0.148" x 3"
For installation in concrete, use Titen
®
2 masonry screw
¼
" x 1
¼
".
Para instalaciones en concreto, utilice Titen de
¼
" x 1
¼
".
Mark
drill holes.
Marque los
agujeros a
taladrar.
Drill
¼
"-diameter hole
½
" deeper than Titen
®
.
Perdore un afujero
de
¼
" de diámetro
a una profundidad
de
½
" mayor que
el Titen
®
.
PPBZ
4848
RPBZ
1
2
5
S1.5
S1.5
S1.5
S1.5
6
4
Side
3
¼
" x 1
½
" Strong-Drive
®
SDS HEAVY-DUTY CONNECTOR Screw
3½" side
cover (min.)
Cubierta
lateral de 3½"
(mín.)
RPBZ
4949
Solid Sawn
Joist Hangers
HUS
1
2
3
4
5
0.162" x 3
½
"
5050
1
LSSJ
1
2
3
4
0.148" x 3"
LSSJ
5151
LRU
4
1
1
2
3
3
2
4
5
5
0.162" x 3
½
"
LRU
5252
LSSR
2
Joist seat nails
3
45˚ max.
1
5353
LSSR
Acute
side
nailing
Joist nails on
obtuse side
4
5
6
7
Model No.
Fasteners
Face
(in.)
Joist
(in.)
LSSR1.81Z
0.148 x 2
½
0.148 x 1
½
LSSR2.1Z
LSSR2.37Z
LSSR2.56Z
LSSR210-2 Z
0.162 x 2
½
0.162 x 2
½
LSSR410Z
5454
LUCZ
Header
Viga Cabezal
0.162" x 3
½
"
Joist
Viga
0.148" x 1
½
"
1
2
3
Upgrade
your
coiled
strap.
Our new high-performance CSHP
coiled strap is easy to install with a
standard pneumatic framing nailer.
Visit go.strongtie.com/cshp
or call
(
800
)
999-5099.
5656
LUS
1
2
3
LUS
5757
LUS
0.162" x 3
½
"
for all
others.
0.162" x 3½"
para
los demás.
0.148" x 3"
for single 2x.
0.148" x 3"
para
un solo 2x.
4
5
6
LUS
5858
SUR/L
0.148" x 1½"
0.162" x 3½"
0.162" x 3
½
"
1
2
3
5959
SUR/L
0.162" x 3
½
"
0.148" x 1
½
"
0.148" x 1
½
"
4
5
6
6060
VPA
Required
Pitch
Inclinación
Requerida
0.148" x 3"
0.148" x 3"
0.148" x 1½"
0.148" x 3"
1
2
3
Adjust to
required
pitch.
Inclinación
requerida.
VPA
6161
VPA
I-Joist
Vigueta
0.148" x 1½"
0.148" x 1½"
Solid Wood
Madera Sólida
4
5
VPA
6262
ITS
0.148" x 3"
The Strong-Grip
seat allows
the I-joist to “snap” in securely —
no joist nails needed.
El asiento Strong-Grip
permite
que la viga ‘I’ “encaje” con firmeza;
no se necesitan clavos para vigas.
90°
1
2
Engineered Wood and
Structural Composite
Lumber Connectors
10d
3
0.148" x 3"
6363
10d
ITS
No nails required in joist.
No es necesario clavar
clavos en la viga.
4
5
6
7
0.148" x 3"
6464
IUS
The Strong-Grip
seat allows the I-joist to
“snap” in securely — no joist nails needed.
El asiento Strong-Grip
permite que la viga
en ‘I’ “encaje” con firmeza; no se necesitan clavos
para vigas.
0.148" x 3"
1
2
3
4
IUS
6565
IUS
No nails required in joist.
No es necesario clavar
clavos en la viga.
5
6
7
8
IUS
6666
DTC
0.131" x 2
½
"
1
2
Plated Truss
Connectors
Install nail in center
of slot.
Instale el clavo en el
centro de la ranura.
Truss nails not driven flush
Los clavos de la cercha no
deberían
asentarse contra el conector
Truss nails not
driven flush.
Los clavos de la
cercha no deberían
asentarse contra
el conector.
6767
Gap
STC
Truss nails not driven flush.
Los clavos de la cercha no
deberían asentarse contra el
conector.
Install nail in center of slot.
Instale el clavo en el centro
de la ranura.
0.131" x 1
½
"
1
2
6868
HTU
0.148" x 3"
for double
2x joists
0.148" x 1
½
"
0.162" x 3
½
"
For double truss, use
0.148" x 3" nails into trusses.
Para cerchas dobles, use clavos
10d x 3" insertados en las cerchas.
0.148" x 1
½
"
4
5
0.162" x 3
½
"
1
2
3
0.162" x 3
½
"
0.148" x 1
½
"
HTU
6969
TSBR
0.148" x 1
½
"
TSBR
7070
THA
Installation on Solid Header
Instalación Sobre Viga Cabezal Sólida
0.162" x 3
½
"
0.148" x 1
½
"
0.148" x 3"
Top-Mount Condition / Condición de Montaje Superior
Face-Mount Condition / Condición de Montaje Sobre Cara
Install joist nails both sides.
Instale clavos para vigas a ambos lados.
Install
joist nails
both
sides.
Instale
clavos
para vigas
a ambos
lados.
1
1
2
2
7171
THA
Model
Modelo
Top and Face
Encima and Cara
Joist
Vigueta
THA29 (16) 0.148" x 3" (4) 0.148" x 3"
THA213
(14) 0.148" x 3" (4) 0.148" x 3"
THA413
THA218 (18) 0.148" x 3" (4) 0.148" x 3"
THA218-2
(22) 0.162" x 3
½
" (6) 0.162" x 3
½
"
THA418
THA422
THA222-2
THA422-2
(30) 0.162" x 3
½
" (6) 0.162" x 3
½
"
THA426
Installation on Solid Header
Instalación Sobre Viga Cabezal Sólida
Nail Location
Ubicación de
Los Clavos
Qty/Nail
Cant./Clavo
Top/Encima (4) 0.162" x 3
½
"
Face/Cara (4) 0.162" x 3
½
"
Joist
Vigueta
Fill all holes
with
0.162” x 3
½
Llene todos los
orificios con
clavos
0.162” x 3
½
Installation on Truss
Instalación Sobre Cercha
Nail Location
Ubicación de
Los Clavos
4x Nailer /
Listón
Clavador 4x
Top/Encima (4) 0.162" x 3
½
"
Face/Cara (4) 0.162" x 3
½
"
Joist
Vigueta
Fill all holes
with
0.162” x 3
½
Llene todos
los orificios con
clavos
0.162” x 3
½
Installation on Nailer
Instalación en
Listón Clavador
Min. 4x nailer
Listón Clavador
4x Como Mínimo
Face / Cara
Top / Encima
Straighten the double-shear
nailing tabs and install nails
straight into the joist.
Enderece las pestañas de
clavado de doble penetración e
instale los clavos rectos en la viga.
Top / Encima
Double 2x4 top chord min.
Viga superior doble de 2x4 como mínimo
Face / Cara
Straighten the double-shear nailing
tabs and install nails straight.
Enderece las pestañas de
clavado de doble penetración
e instale los clavos rectos.
7272
THJA
Left-hand hip
installation similar.
Similar a la instalación
‘izquierda’ de cumbre.
Left hand hip
installation similar
Similar a la instalación
‘izquierda’ de cumbre
0.162" x 3
½
" 0.162" x 3
½
"
0.148" x 1
½
"
0.148" x 1
½
"
0.148" x 1½"
0.162" x 3½"
1
2
3
4
7373
THJU
0.148" x 3"
1
2
3 4
7474
0.148" x 1
½
"
Quantity per
Designer.
Cantidad
según
indicaciones
del diseñador.
Masonry
Connectors
HETA/META
1
2
3
7575
HETA/META
4
5
Moisture barrier not shown (typ.)
La barrera contra la humedad no
se muestra (típ.)
7676
LGT
LGT2 shown. LGT3
and LGT4 similar.
For wood-to-wood
connections using
the LGT, visit
strongtie.com.
Se muestra LGT2.
Similar a LGT3 y LGT4.
Para conexiones de
madera a madera
usando el LGT, visite
strongtie.com.
Titen 2 Masonry Screw / Tornillo para mampostería (
¼
" x 2
¼
")
For installation in concrete, use Titen 2
¼
" x 1
¾
".
Para instalaciones en concreto, utilice Titen 2 de
¼
" x 1
¾
".
Fill holes with
Titen
®
2 masonry screws.
Llene los orificios
con tornillos para
mampostería Titen
®
.
⁄
" Drill Bit
Broca de
⁄
"
Compressed Air
Aire Comprimido
1
2
3
7777
LGT
0.148" x 3
¼
"
4
5
6
LGT2 shown. For
installation of
LGT3/LGT4, see
strongtie.com.
Se muestra LGT2.
Para la instalación
de LGT3/ LGT4,
consulte
strongtie.com.
7878
VGT
Use
3
8
" driver.
Use un
destornillador de
⁄
".
If using an adhesive anchor, see
pages 106–107 for instructions.
Si utiliza un anclaje adhesivo,
consulte las instrucciones de las
páginas 106–107.
1
4
"
x 3" Strong-Drive
®
SDS HEAVY-DUTY CONNECTOR Screw
1
7979
VGT
2
3
8080
Straps
and Ties
A35
0.131" x 1
½
"
1
1
2
2
3
3
4
This
side Up
This
side Up
8181
This
side Up
This
side Up
2
1
3
CSHP
Model /
Modelo
Lumber Species / Especies de Madera
Douglas Fir-Larch / Southern Pine Spruce-Pine-Fir / Hem-Fir
End
Length /
Largo del
Extremo
Cut
Length /
Largo a
Cortar
Total
Fasteners /
Total de
Clavos
End
Length /
Largo del
Extremo
Cut
Length /
Largo a
Cortar
Total
Fasteners /
Total de
Clavors
CSHP18
10"
Clear Span
(Luz) + 20"
(16)
0.131" x 2
½
"
11"
Clear Span
(Luz) + 22"
(18)
0.131" x 2
½
"
9"
Clear Span
(Luz) + 18"
(14)
0.148" x 2
½
"
10"
Clear Span
(Luz) + 20"
(16)
0.148" x 2
½
"
CSHP20
8"
Clear Span
(Luz) + 16"
(12)
0.131" x 2
½
"
9"
Clear Span
(Luz) + 18"
(14)
0.131" x 2
½
"
8"
Clear Span
(Luz) + 16"
(12)
0.148" x 2
½
"
8"
Clear Span
(Luz) + 16"
(12)
0.148" x 2
½
"
See strongtie.com/cshp for
framing nailer use.
Consulte strongtie.com/cshp
para el uso de clavadoras
para entramados.
8282
CS/CMST14
CMST requires
minimum (2) 2x studs
CMST requiere puntales
de (2) 2x como mínimo
Provide min. 1" end
distance for CS and CMST
Dejar al menos 1" y
distancia para CS y CMST
Equal number of
specified nails in each end
Igual cantidad de clavos
especificados en cada extremo
No nails
required here
No necesita
clavos aquí
End length
Largo del
extremo
End length
Largo del
extremo
CS14
Shown
Mostrado
Quantity per Designer.
Cantidad según
indicaciones del
diseñador.
Sheathing not
shown for clarity.
No muestra el
revestimento para
mayor claridad.
0.148" x 2
½
"
0.131" x 2
½
"
0.162" x 3
½
"
1
2
3
8383
CS/CMST14
Note: Install half of the total fasteners in each end of strap.
Clear Span = Luz
Nota: Instale la mitad de la cantidad total de sujetadores
en cada extremo del eje.
Across joists.
Sobre varias viguetas.
Sheathing not
shown for clarity.
No muestra el
revestimento para
mayor claridad.
Model /
Modelo
Lumber Species / Especies de Madera
Douglas Fir-Larch / Southern Pine Spruce-Pine-Fir / Hem-Fir
End
Length /
Largo del
Extremo
Cut
Length /
Largo a
Cortar
Total
Fasteners /
Total de
Clavos
End
Length /
Largo del
Extremo
Cut
Length /
Largo a
Cortar
Total
Fasteners /
Total de
Clavors
CS14
CS14-R
16"
Clear Span
(Luz) + 32"
(30)
0.131" x 2
½
"
19"
Clear Span
(Luz) + 38"
(36)
0.131" x 2
½
"
15"
Clear Span
(Luz) + 30"
(26)
0.148" x 2
½
"
16"
Clear Span
(Luz) + 32"
(30)
0.148" x 2
½
"
CS16
CS16-R
13"
Clear Span
(Luz) + 26"
(22)
0.131" x 2
½
"
15"
Clear Span
(Luz) + 30"
(26)
0.131" x 2
½
"
11"
Clear Span
(Luz) + 22"
(20)
0.148" x 2
½
"
13"
Clear Span
(Luz) + 26"
(22)
0.148" x 2
½
"
CS20
CS20-R
9"
Clear Span
(Luz) + 18"
(14)
0.131" x 2
½
"
9"
Clear Span
(Luz) + 18"
(16)
0.131" x 2
½
"
7"
Clear Span
(Luz) + 14"
(12)
0.148" x 2
½
"
9"
Clear Span
(Luz) + 18"
(14)
0.148" x 2
½
"
CMST12
39"
Clear Span
(Luz) + 79"
(86)
0.148" x 2
½
"
44"
Clear Span
(Luz) + 89"
(98)
0.148" x 2
½
"
33"
Clear Span
(Luz) + 68"
(74)
0.162" x 2
½
"
38"
Clear Span
(Luz) + 77"
(84)
0.162" x 2
½
"
CMST14
30"
Clear Span
(Luz) + 61"
(66)
0.148" x 2
½
"
34"
Clear Span
(Luz) + 70"
(76)
0.148" x 2
½
"
26"
Clear Span
(Luz) + 52"
(56)
0.162" x 2
½
"
30"
Clear Span
(Luz) + 61"
(66)
0.162" x 2
½
"
CMSTC16
20"
Clear Span
(Luz) + 41"
(50)
0.148" x 3
¼
"
25"
Clear Span
(Luz) + 50"
(58)
0.148" x 3
¼
"
8484
H1 — Rafter/Cabrio
H1 Reversed
H1 Invertido
0.131" x 1
½
"
Rafter
Cabrio
Plate
Placas
0.131" x 2
½
"
0.131" x 1
½
"
1
0.131" x 1
½
"
2
3
4
0.131" x 2
½
"
H1
8585
H1 — Truss/Viga
0.131"x1
½
"
Truss
Viga
Plate
Placas
0.131" x 2
½
"
H1 Reversed
H1 Invertido
4
0.131" x 2
½
"
1
0.131" x 1
½
"
2
0.131" x 1
½
"
3
H1
8686
H2.5A
Installations in Pairs
Both connectors shall be
same model.
Plan View
Vista de Planta
Install diagonally
across from each
other for minimum
2x truss.
Instale
diagonalmente
uno respecto del
otro para dejar una
cercha de
2x como mínimo.
Instalaciones en Pares
Ambos conectores deben
ser del mismo modelo.
0.131" x 2
½
"
Truss
Viga
Placa superior
de la pared
Wall
top plate
1
Rafter
Cabrio
2
3
8787
H2.5T
Plan View
Vista de Planta
Products can be on the same
side of the wall provided they
are configured as shown.
Los productos se pueden
instala a ambos lados de
la pared siempre que se
configuren como se muestra.
0.131" x 2
½
"
Rafter
Cabrio
1
2
Truss
Viga
3
½"
3
8888
H10A — Rafter/Cabrio
0.148" x 1
½
"
1
2
3
H10A
8989
H10A — Blocking/Entramado
1
2
3
4
5
0.131" x 2
½
"
H10A
9090
LS
1a1a
1b
2a 2b
3a 3b
0.148" x 1
½
"
9191
LSTA
0.148" x 2
½
"
Hanger not shown
for clarity.
El soporte colgante no
se muestra para ofrecer
mayor claridad.
1
2
3
9292
LTP4/LTP5
Fasteners:
LTP4
No sheathing: 0.131" x 1
½
"
Over sheathing (
" thick max.): 0.131" x 2
½
"
LTP5
No sheathing: 0.131" x 1
½
"
Over sheathing (
½
" thick max.): 0.131" x 2
½
"
Sujetadores:
LTP4
Sin relleno: 0.131" x 1
½
"
Sobre relleno (
" de espesor máx.): 0.131" x 2
½
"
LTP5
Sin relleno: 0.131" x 1
½
"
Sobre relleno (
½
" de espesor máx.): 0.131" x 2
½
"
0.131" x 1
½
"
0.131" x 2
½
"
9393
RBC
0.148" x 1
½
"
3
/4"
Up to
Hasta
1
2
3
4
Up to
¾
"
Hasta ¾"
9494
MST
Clear
span
No nails
required here
No necesita
clavos aquí
Largo del
extremo
End length
Largo del
extremo
End length
LUZ
0.162" x 2
½
"
No Sheathing / Sin Relleno
1
2
3
9595
MST
With Sheathing / Con Relleno
0.162" x 3
½
"
Clear
span
No nails
required here
No necesita
clavos aquí
Largo del
extremo
End length
Largo del
extremo
End length
LUZ
1
2
3
9696
RSP
0.131" x
1½
"
1
2
3
4
9797
SP
0.148" x 3"
1
2
1
2
9898
SSP
Alternative with Double Top Plate
Alterne con una Placa Superior Doble
0.148" x 3"
Installation on Mudsill
Instalación sobre Durmientes
Single Plate Installation
Instalación de placa sencilla
9999
TSP
1
2
3
0.148" x 3"
100100
DTT1Z
Deck
Connectors
3" embedment
3" empotramiento
#9 x 1
½
"
Strong-Drive
SD CONNECTOR Screw
Strong-Drive
®
SDWH TIMBER-HEX
HDG Screw
1
2
3
DTT1Z
101101
DTT2Z
2"
2"
¼
" x 1
½
" Strong-Drive
®
SDS HEAVY-DUTY CONNECTOR Screw
Threaded Rod
1
2
3
102102
Miscellaneous
HSS
¼
" x 1
½
" Strong-Drive
®
SDS HEAVY-DUTY CONNECTOR Screw
Use
" driver.
Use un
destornillador
de
".
Bend flanges one time only.
Doble las alas una vez.
2
1
3
4
103103
PSPN
0.162" x 3
½
"
1
2
3
4
104104
Cut
" kerf.
Corte un corte
de
".
0.162" x 3
½
"
at plates /
en las soleras
0.131" x 2
½
"
at studs /
en los
montantes
1
2
3
4
TWB
105105
TWB
0.131" x 2
½
"
(2) 0.162" x 3
½
"
(2) 0.162" x 3
½
"
6
5
7
8
106106
Adhesive Anchoring / Anclaje Adhesivo
(AT-XP
®
, SET-3G
®
, and SET-XP
®
)
1
2
3
Anchoring and Fastening
Systems for Concrete
and Masonry
Compressed air (80 psi min.),
4 seconds (min.) — AT-XP,
SET-XP
2 seconds (min.) — SET-3G
Aire comprimido (80 psi mín.),
4 segundos (mín.) — AT-XP,
SET-XP
2 segundos (mín.) — SET-3G
Nylon brush
4 cycles (min.) — AT-XP,
SET-XP
Wire brush
2 seconds (min.) — SET-3G
Cepillo de nylon
4 ciclos (mín.) — AT-XP,
SET-XP
Cepillo de alambre
2 segundos (mín.) — SET-3G
Anchoring and Fastening Systems for Concrete
and Masonry
Adhesive Anchoring
107107
Adhesive Anchoring
Anclaje Adhesivo
Fill ½ to 2/3
Llene ½ a 2∕3
Compressed air (80 psi min.),
4 seconds (min.) — AT-XP, SET-XP
2 seconds (min.) — SET-3G
4
5
6
Dispense until mixed properly
(uniform color).
Suministre hasta que esté bien
mezclado (color uniforme).
Aire comprimido (80 psi mín.),
4 segundos (mín.) — AT-XP,
SET-XP
2 segundos (mín.) — SET-3G
Adhesive Anchoring
108108
2
1
/2
" min.
Washer or bearing plate as
required by building code.
Arandela o disco de presión
según lo requiera el código
de construcción.
3
1
Titen HD
®
Titen HD®
109109
Strong-Drive
®
SDWC Truss Screw
Fastening Systems
Strong-Drive® SDWC Truss
Screw
Fastening Systems
Metal
installation
guide tool
Herramienta
guía de
instalación de
metal
Installation
guide
channel
Canal de guía
de instalación
Installation
angle limit
Límite de
ángulo para
instalación
½
" max.
Optimal 22
o
30
o
10
o
0
o
SDWC15600
3"
4
SDWC15600
SDWC15600
5
SDWC15600
1
Metal
installation
guide tool
Herramienta
guía de
instalación de
metal
Installation
guide
channel
Canal de guía
de instalación
2
3
Note: SDWC Truss screws
can also be installed using
the Quik Stik
Rafter and
Truss Fastening System.
110110
2" min.
Inside Wall View
Vista del muro desde dentro
Locator tab
Pestaña del localizador
TUW
Take-up washer
Arandela de recogida
Outside Wall View
Vista del muro desde afuera
1
2
13
4
5
Strong-Drive
®
SDWF
Floor-to-Floor Screw
#9 x 2
½
" Strong-Drive
SD Connector Screw
Strong-Drive®
SDWF
Floor-to-Floor Screw
111111
Strong-Drive
®
SDWF
Floor-to-Floor Screw
Outside Wall View
Vista del muro desde afuera
SDWF depth guide
(included)
Inside Wall View
Vista del muro desde afuera
5"
SDWF
(U.S. Patent 8,276,323)
3½"
TUW
(U.S. Patent 8,276,323)
3¼"
6
7
1" min.
Lower-wall,
top-plate
splice shown
Se muestra
el empalme de
placa superior a
muro inferior
Upper-wall,
bottom-plate
splice shown
Se muestra
el empalme de
placa inferior a
muro superior
Rim
joist
4" min.
end
distance
4" min.
distancia
al borde
One Strong-Drive SDWF
Floor-to-Floor screw
must be installed between
4
" and 12" on each
side of any upper-wall,
bottom-plate splice.
Se debe instalar un
tornillo de entre 4" y 12"
en cualquier lado de
cualquier empalme de placa
inferior a muro superior.
Typical Strong-Drive SDWF FLOOR-TO-FLOOR
and TUW Installation
TUW
(U.S. Patent 8,276,323)
SDWF
(U.S. Patent 8,276,323)
Strong-Drive®
SDWF
Floor-to-Floor Screw
© 2019 Simpson Strong-Tie Company Inc.
S-C-INSTALL19 8/19 exp. 12/21
We now have a
web version of
this installers
guide.
Check it out at
strongtie.com/installersguide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112

Simpson Strong-Tie FPBB44 Guía de instalación

Tipo
Guía de instalación