72/76 - MCSi-C0 Regulación AC Brushless digital - Ref.1504
LISTA DE PARÁMETROS, VARIABLES Y
COMANDOS. IDS DE CAN
Mnem. Nombre Nivel Id CAN Id ModBus Acc. Mín. Máx. Def. Unid. Pág.
BV14 NotProgrammableIOs FAGOR 0x40CC 08601 RO 0 65535 - - 53
CP1 CurrentProportionalGain FAGOR 0x506A 00213 RW 0 999 - - 53
CP2 CurrentIntegralTime FAGOR 0x506B 00215 RW 0 999 - - 53
CP20 CurrentLimit USUARIO 0x4133 08807 RW 0 50,00 - A 53
CP30 CurrentCommandFilter1Type FAGOR 0x4134 08809 RW 0 1 0 - 53
CP31 CurrentCommandFilter1Frequency FAGOR 0x4138 08817 RW 0 4000 0 Hz 54
CP32 CurrentCommandFilter1Damping FAGOR 0x4139 08819 RW 0 1000 0 Hz 54
CV1 Current1Feedback BÁSICO 0x4135 08811 RO -50,00 50,00 - A 54
CV2 Current2Feedback BÁSICO 0x4136 08813 RO -50,00 50,00 - A 54
CV3 CurrentFeedback BÁSICO 0x4137 08815 RO -50,00 50,00 - A 55
CV10 Current1Offset FAGOR 0x4131 08803 RO -2,000 2,000 - A 55
CV11 Current2Offset FAGOR 0x4132 08805 RO -2,000 2,000 - A 55
DC1 ResetClass1Diagnostics BÁSICO 0x5063 00199 RW 0 15 0 - 56
DC2 ClearHistoricOfErrorsCommand BÁSICO 0x4192 08997 RW 0 15 0 - 56
DV17 HistoricOfErrors BÁSICO 0x419A 09012 RO - ----- - - 55
DV31 DriverStatusWord FAGOR 0x5087 00271 RO 0 65535 - - 55
DV32 MasterControlWord FAGOR 0x5086 00269 RW 0 65535 0 - 56
GC1 BackupWorkingMemoryCommand USUARIO 0x5108 00529 RW 0 15 0 - 58
GC10 LoadDefaultsCommand USUARIO 0x5106 00525 RW 0 15 0 - 58
GP3 StoppingTimeout USUARIO 0x42BE 09597 RW 0 9999 500 ms 57
GP5 ParameterVersion USUARIO 0x42C0 09601 RO - - - - 57
GP9 DriveOffDelayTime USUARIO 0x50CF 00415 RW 0 9999 50 ms 57
GV2 ManufacturerVersion USUARIO 0x501E 00060 RO - - - - 57
GV5 CodeChecksum USUARIO 0x42C2 09605 RO - - - -
57
GV7 Password USUARIO 0x510B 00535 RW 0 9999 0 - 57
GV9 DriveType USUARIO 0x508C 00280 RO - - - - 57
GV11 SoftReset USUARIO 0x42C4 09609 RW 0 16 0 - 57
GV16 MotorTableVersion USUARIO 0x42CC 09625 RO - - - - 58
GV75 ErrorList FAGOR 0x5177 00750 RO - - - - 58
HV5 PLDVersion USUARIO 0x4127 08783 RO - - - - 58
IP6 DigitalInputPolarity BÁSICO 0x438E 10013 RW 0 1 0 - 58
IV10 DigitalInputs BÁSICO 0x438B 10007 RO 0 1 - - 58
KP3 ExtBallastPower BÁSICO 0x445A 10421 RW 200 2000 200 W 59
KP4 ExtBallastEnergyPulse BÁSICO 0x445C 10425 RW 200 2000 200 J 59
KV10 CoolingTemperature BÁSICO 0x444E 10397 RO 0 200 - °C 59
KV32 I2tDrive BÁSICO 0x4455 10410 RO 0 100 - % 59
KV36 I2tMotor BÁSICO 0x4457 10415 RO 0 100 - % 59
KV40 I2tCrowbar BÁSICO 0x445B 10423 RO 0 100 - % 59
KV41 BallastSelect BÁSICO 0x445D 10427 RW 0 1 1 - 59
MP1 MotorType USUARIO 0x508D 00282 RO - - - - 60
MP2 MotorTorqueConstant FAGOR 0x44B0 10593 RO 0 10,00 - Nm/A 60
MP3 MotorContinuousStallCurrent FAGOR 0x506F 00223 RO 0 50,00 - A 60
MP4 MotorPeakCurrent FAGOR 0x506D 00219 RO 0 50,00 - A 60
NP116 ResolutionOfFeedback1 FAGOR 0x5074 00233 RO 0 65535 - pulsos 60
NP121 InputRevolutions FAGOR 0x5079 00243 RW 1 65535 1 vueltas 60
NP122 OutputRevolutions FAGOR 0x507A 00245 RW 1 65535 1 vueltas 60
NP123 FeedConstant FAGOR 0x507B 00246 RW 0
2
31
-1
-- 60
OP6 DigitalOutputPolarity BÁSICO 0x4588 11025 RW 0 1 0 - 61
OV10 DigitalOutputs BÁSICO 0x4582 11013 RW 0 1 0 - 61
PC146 NCControlledHoming FAGOR 0x5092 00293 RW 0 15 0 - 61
PV51 PositionFeedback1 FAGOR 0x5033 00102 RO
-2
31
-1 2
31
-1
- pulsos 61
PV173 MarkerPositionA FAGOR 0x50AD 00346 RO
-2
31
-1 2
31
-1
- pulsos 61
QP1 ControlUnitCycleTime FAGOR 0x5001 00003 RW 0 10000 4000 - 62
QP17 CanOpenBorder BÁSICO 0x47E4 12233 RW - - - - 62