Eaton E5148C142 Series Operating Instructions Manual

Tipo
Operating Instructions Manual
MN05401009E 1
english
español
françaisdeutsch
Operating Instructions
Electronic Preset Counter
E5148C142 Series
1. Description
– 6 digit preset counter, 1 preset, add./subtr.
– bright 2-line LCD display with symbols for activated
output and current preset value
– count and preset range – 999999 to 999999, over- or
underflow without count loss up to 1 decade (will be
indicated by flashing of the display with 1 Hz
frequency)
– programmable to operate as a preset counter, timer or
frequency meter
– relay or optocoupler output
– programming of count functions/operating parameters
via the setting keys. During programming the display
guides the user with text prompts.
– programmable features:
operating mode (output signal at zero or at preset
point, with or without automatic reset)
decimal point
polarity of the inputs (NPN or PNP)
input mode and scaling factor
output signals to be permanent or timed
gate time when programmed as a frequency meter
resolution when programmed as a timer (s, min, h or
h:min:s)
– supply voltage 230V AC, 115V AC, 48V AC, 24V AC or
11 – 30V DC
– backlit display (optional)
2. Inputs
2.1 INP A, INP B
Count inputs; max. count frequency 30 Hz or 10 kHz
separately selectable for both inputs via programming
switches C and D at the right side of the housing.
2.2 Gate
Static input; no counting while this input is activated.
If operated as a timer (only h, min and 0.1 min resolu -
tions), the decimal point between the 5th and 6th
decade flashes while gate input is not activated
(operating indication).
2.3 Reset
Dynamic input; switched in parallel with the red set key
and sets the counter to zero (adding mode) or to the
preset value (subtracting mode).
DIP switch
INP A INP B
30 Hz 10 kHz 30 Hz 10 kHz
D ON OFF
C ON OFF
ABCD
OFF
ON
2.4 Key
Static keyboard lock input. While this input is activated, it
is neither possible to reset the counter nor to change the
preset value.
3. Display
—— count value
—— preset value
symbol for activated output
indicator for current preset value
4. Output
Relay with potential free change-over contact or
optocoupler with open collector and emitter.
Activated output will be indicated by I.
For safety circuits the operation of the relay, or the
optocoupler may be inverted. Thus the relay coil will be
dead, or the optocoupler will be locked when reaching
the preset point. For this application, the output signal
Out 1 must be set to
l
(permanent signal) or
l
l
(timed signal) during the programming routine.
Caution: For operating modes with automatic reset
(AddAr, SubAr) the duration of the timed signal for the
output has to be programmed, otherwise the output
signal has no defined duration (see programming).
5. Setting of the operating parameters
a. connect to supply voltage
b. set DIP switch “A” (right side of the housing) to “ON”
for a short time. Display will show 1st menu item
“Mode”.
c. select required function via key
d. press P-key to store selected function/enter data and
to change over to next menu item.
e. select the desired function again via key to enter
data (prescaling factor, duration of timed signal, gate
time, resolution) directly via the two arrow-keys.
f. After programming the last menu item (permanent or
timed signal), the programming routine will be exited
by pressing the P-key, if DIP switch “A” is set to
“OFF”. If it is still set to “ON”, the programming
routine will be passed through once again.
ABCD
OFF
ON
2 MN05401009E
6. Setting of the operating mode
6.1 Selection of basic function
After DIP switch “A” has been switched to “ON” for a
short time, one of the basic functions will be displayed
as follows:
programming
routine
Impulse Counter
programming
routine
Timer
programming
routine
Frequency Meter
6.2.1 Programming routine Impulse Counter
Scaling factor:
0.0001…9.9999
Setting with and keys
Factor 0.0000 wonʼt be accepted
Caution! In operating modes Sub
and SubAr (output signal at
count value = zero) the preset
value has to be evenly divisible
by the factor, otherwise the
counter — when reset — will be
set to the next integer multiple of
the factor.
Decimal point
(only optical function)
0 = no decimal point
0.0 = one decimal place
0.00 = two decimal places
0.000 = three decimal places
Permanent signal of the output,
activated at count value ≥ preset
value in adding mode and at
count value ≤ zero in subtracting
mode*
Permanent signal of the output,
will become passive at count
value ≥ preset value in adding
mode and at count value ≤ zero
in subtracting mode**
Timed signal of the output, will
become passive at count value =
preset value in adding mode
and at count value = zero in
subtracting mode**
Timed signal of the output,
activated at count value = preset
value in adding mode and at
count value = zero in subtracting
mode*
Duration of timed signal of the
output can be set from 00.01 s to
99.99 s
* Activation of relay coil or
optocoupler when reaching the
preset value
** Relay coil becomes dead or
optocoupler will be locked when
reaching the preset value.
Operating mode Add:
Adding mode
Permanent signal at count value ≥
preset value or timed signal at
count value = preset value
Reset to zero
Operating mode Sub:
Subtracting mode
Permanent signal at count value ≤
zero or timed signal at count value
zero. Reset to preset value
Operating mode AddAr:
Adding mode
Timed signal at count value =
preset value
Automatic reset to zero
Operating mode SubAr:
Subtracting mode
Timed signal at count value = zero
Automatic reset to preset value
Polarity of the inputs:
pospol: positive polarity (PNP)
sourcing from + 24V
negpol: negative polarity (NPN)
sinking to 0V
Input modes:
E1: INP A = count input
INP B = count direction input
E2: INP A = count input adding
INP B = count input subtr.
E3: Quadrature input
INP A = count input 0°
INP B = count input 90°
E4: same as E3, but with pulse
doubling.
Each pulse edge of INP A will
be counted.
MN05401009E 3
english
Operating mode Add:
Adding mode
Permanent signal at count value
≥ preset value or timed signal at
count value = preset value
Reset to zero
Operating mode Sub:
Subtracting mode
Permanent signal at count value
≤ zero or timed signal at count
value = zero. Reset to preset
value
Operating mode AddAr:
Adding mode
Timed signal at count value =
preset value. Automatic reset to
zero
Operating mode SubAr:
Subtracting mode
Timed signal at count value = zero
Automatic reset to preset value
Polarity of the inputs:
pospol: positive polarity (PNP),
soucing from + 24V
negpol: negative polarity (NPN),
sinking to 0V
Unit of time:
Timing in s; 0.1 s; 0.01 s or 0.001 s*
Timing in min; 0.1 min; 0.01 min*
or 0.001 min*
Timing in h; 0.1 h; 0.01 h or 0.001 h*
* depending on position of the
decimal point
Timing in h: min: s
Decimal point (resolution):
0 = no decimal point
0.0 = one decimal place
0.00 = two decimal places
0.000 = three decimal places
Permanent signal of the output,
activated at count value ≥ preset
value in adding mode and at
count value ≤ zero in subtracting
mode *
Permanent signal of the output
will become passive at count
value ≥ preset value in adding
mode and at count value ≤ zero
in subtracting mode**
Timed signal of the output, will
become passive at count value
= preset value in adding mode
and at count value = zero in
subtracting mode**
Timed signal of the output,
activated at count value = preset
value in adding mode and at
count value = zero in subtracting
mode*
Duration of timed signal of the
output, can be set from 00.01s
to 99.99 s.
* Activation of relay coil or
optocoupler when reaching the
preset value
** Relay coil becomes dead or
optocoupler will be locked when
reaching the preset value.
6.2.2 Programming routine Timer
4 MN05401009E
Gate time = within this period the
incoming pulses will be counted
and displayed.
Programmable range from 00.01 s
to 99.99 s
Setting with and keys
00.00 wonʼt be accepted
Polarity of the inputs:
pospol: positive polarity (PNP),
sourcing sensor
negpol: negative polarity (NPN),
sinking sensor
Input modes:
E1: INP A = count input
INP B = count direction input
E2: INP A = count input adding
INP B = count input subtr.
E3: Quadrature input
INP A = count input 0°
INP B = count input 90°
E4: same as E3, but with pulse
doubling.
Each pulse edge of INP A will
be counted.
Scaling factor:
0.0001…9.9999
Setting with and keys
Factor 0.0000 wonʼt be accepted
Decimal point
(only optical function):
0 = no decimal point
0.0 = one decimal place
0.00 = two decimal places
0.000 = three decimal places
Permanent signal of the output,
activated at count value ≥ preset
value*
Permanent signal of the output,
will become passive at count
value ≥ preset value**
Timed signal of the output, will
become passive at count value =
preset value**
Timed signal of the output,
activated at count value = preset
value*
Duration of timed signal of the
output can be set from 00.01 s to
99.99 s
* Activation of relay coil or
optocoupler when reaching the
preset value
** Relay coil becomes dead or
optocoupler will be locked when
reaching the preset value.
6.2.3 Programming routine Frequency Meter
MN05401009E 5
english
Setting of the 6th decade
7. Programming of the Preset Value:
After pressing one of the arrow keys, the leading zero
blanking will be suppressed for approx. 4 seconds and
the least significant digit of the preset value flashes with
a frequency of 1 Hz.
The value of the flashing digit can be increased by using
the
key. With the key it will be changed to the next
digit. If no key is pressed for 4 seconds, the
leading zero blanking will be activated automatically
again.
In operating mode Impulse Counter and Frequency
Meter the new value will be selected.
Caution! Do not change presets with output powered.
7.1 Setting of the sign
Select the sign by using the key. The sign will start to
flash now and can be assigned to the preset value or
eliminated by using the key.
If no key is pressed for 4 seconds, the leading zero
blanking will be activated automatically again. Preset
value and count value are displayed now with the
corresponding sign. Intent of negative presets is to allow
reset to a negative value.
Caution! In case of automatic reset no negative values
are to be set for the preset value.
8. Examples for application connections:
Count pulses from contact closure
(programmed polarity PNP)
Count pulses from a light barrier
Count pulses from a shaft encoder
6 MN05401009E
9. Connections
9.1 Plug connection X1
Terminal AC version DC version
No.
1 no connection
2 no connection
3 relay output common contact (C)
optocoupler output emitter
4 relay output normally open contact (NO)
5 relay output normally closed contact (NC)
optocoupler output collector
6 90 – 260V AC/ 11 – 30V DC
48V/24V AC operating voltage
7 90 – 260V AC 0V DC (GND)
48V/24V AC
Caution! For settings
l
and
l
l
(inverted operation of
relay or optocoupler) the connections of terminal 4 and 5
change as follows:
Terminal AC and DC versions
No.
4 relay output normally closed contact (NC)
5 relay output normally open contact (NO)
9.2 Plug connection X2
Terminal Designation Function Function
No. 230V/115V AC 11 – 30V DC
48V/24V AC version
version
1 + 24V DC
Transmitter voltage
2 GND 0V DC reference
voltage
3 INP A count input A
4 INP B count input B
5 RESET reset input
6 GATE gate input
7 KEY keyboard lock input
10. Technical Data
Supply voltage:
90 – 260V AC, 48V AC, 24V AC,
50/60 Hz, ±10 %,
max. 4 VA
or 11 – 30V DC, max. 0.1 A
Display: 6 digit, 2-line 7 segment LCD display
with sign
count value 9 mm [0.35 in.] high characters
preset value 7 mm [0.28 in.] high characters
symbols for displayed preset and closed
output contact
Polarity of input signals:
programmable, all inputs in common
Input sensitivity:
approx. 10 kOhm
Count frequency:
via DIP switches separately selectable for
INP A and INP B
30 Hz
10 kHz (7 kHz for input modes E3 and E4,
quadrature inputs)
in case of automatic reset 900 Hz
without count losses (500 Hz for input
mode E4)
Min. pulse length of the control inputs:
5 ms
Input sensitivity:
For AC supply voltages
Log “0”: 0 – 4V DC
Log “1”: 12 – 30V DC
For DC supply voltage U
b
Log “0”: 0 – 0.2 x U
b
Log “1”: 0.6 x U
b
– 30V DC
U
b
= Supply Voltage
Pulse shape: variable (Schmitt Trigger characteristic)
Output: Relay with potential free make or break
contact
switching voltage max.
250V AC/300V DC
switching current max. 3 A
switching current for DC min. 30 mA
switching performance max. 50W for DC
and max. 2000 VA for AC
or
optocoupler with open collector and emitter
switching performance: 30V DC/15 mA
V
ce sat
at I
c
= 15 mA: max. 2.0V
V
ce sat
at I
c
= 5 mA: max. 0.4V
Responding time of outputs:
Relay: approx. 6 ms
Optocoupler: approx. 1 ms
Data retention:
min. 10 years or 10
6
memory cycles
Transmitter voltage:
24V DC –40 % / +15 %, 80 mA
unregulated for 24 and 48V AC-versions
24V DC –40 % / +15 %, 100 mA
unregulated for 90 – 260V AC-versions
MN05401009E 7
english
Fuse protection:
recommended fuse
for DC: 0.125 A Time Delay
for 90 – 260V AC: 0.05 A Time Delay
for 48V AC: 0.2 A Time Delay
for 24V AC: 0.4 A Time Delay
Noise immunity:
EN 55011 class B and EN 50082-2
with shielded data inputs
Ambient temperature:
0 to 50°C [32 to 122°F]
Storage temperature:
-25 to 70°C [-13 to 158°F]
Weight: approx. 240 g [8.46 oz.]
(AC-version with relay)
Front panel rating:
IP 65
Color of housing:
black
Cleaning: The front of the unit is only to be cleaned
with a soft cloth moistened with water.
11. Contents:
– Counter
– Screw terminal plug 7 poles, 5.08 mm [0.2 in] spacing
– Screw terminal plug 7 poles, 3.81 mm [0.15 in.]
spacing
– Bezel for screw mount, panel cut-out 50 x 50 mm
[1.97 x 1.97 in.]
– Bezel for clip mount, panel cut-out 50 x 50 mm
[1.97 x 1.97 in.]
– Panel mounting clip
12. Ordering Code
E5148C142X
1 = 90 – 260V AC
2 = 10 – 30V DC
8 MN05401009E
Dimensions in mm [in.]:
Panel cut-out 45 x 45 [1.77 x 1.77]
Shown with front frame No. 2
panel cut-out 50 x 50 [1.97 x 1.97]
Shown with front frame No. 3
panel cut-out 50 x 50 mm [1.97 x 1.97]
Sinking
DIN 74
– Subject to changes without prior notice –
48 [1.89]
55 [2.17]
60 [2.36]
48 [1.89]
55 [2.17]
75 [2.95]
86.5 [3.41]
85.5 [3.37]
85.5 [3.37]
15.5
[0.61]
15.5
[0.61]
15.5
[0.61]
3 [0.12]
4 [0.16]
4 [0.16]
max. 10.5 [0.41]
max. 9.5 [0.37]
45 [1.77]
45 [1.77]
45 [1.77]
63 [2.48]
50 [1.97]
50 [1.97]
max. 9.5 [0.37]
MN05401009E 9
español
Instrucciones de operación
Contador electrónico preconfigurado
Serie E5148C142
1. Descripción
– Contador preconfigurado de 6 dígitos, 1 valor
preconfigurado, adición/sustracción.
– Pantalla LCD brillante de 2 líneas con símbolos para
la salida activada y el valor preconfigurado de corriente.
– Rango de conteo y preconfigurado (de – 999999 a
999999), sobre o bajo el flujo sin pérdidas de conteo
de hasta 1 decimal (se indicará mediante destellos de
la pantalla con una frecuencia de 1 Hz).
– Programable para operar como un contador,
temporizador o medidor de frecuencia preconfigurado.
– Salida de relé u optoacoplador.
– Programación de funciones de conteo/parámetros de
operación por medio de las teclas de configuración.
Durante la programación, la pantalla guía al usuario
con indicaciones de texto.
– Funciones programables:
Modo de funcionamiento (señal de salida en cero o en
un punto preconfigurado, con o sin restablecimiento
automático)
Punto decimal
Polaridad de las entradas (NPN o PNP)
Modo de entrada y factor de escala
Señales de salida que serán permanentes o
temporizadas
Tiempo de cómputo cuando se programa como
medidor de frecuencia
Resolución cuando se programa como temporizador
(s, min, h u h:min:s)
– Voltaje de suministro 230 V CA, 115 V CA, 48 V CA,
24 V CA o 11 a 30 V CC
– Pantalla con luz posterior (opcional)
2. Entradas
2.1 ENTRADA A, ENTRADA B
Entradas de conteo; frecuencia máxima de conteo de
30 Hz o 10 kHz que se pueden seleccionar por separado
para ambas entradas mediante interruptores de
programación C y D en el costado derecho de la cubierta.
2.2 Cómputo
Entrada estática; no se efectúa conteo mientras esta
entrada está activada. Si se opera como temporizador
(sólo resoluciones de horas, minutos y 0,1 minuto), el
punto decimal entre el quinto y sexto decimal destella
mientras la entrada de cómputo no está activada
(indicación de funcionamiento).
2.3 Restablecimiento
Entrada dinámica; entra en funcionamiento en paralelo
con la tecla de configuración roja y ajusta el contador en
cero (modo de adición) o en el valor preconfigurado
(modo de sustracción).
Conmutador
DIP
ENT A ENT B
30 Hz 10 kHz 30 Hz 10 kHz
D ON OFF
C ON OFF
ABCD
OFF
ON
2.4 Tecla
Entrada de bloqueo del teclado estático. Mientras esta
entrada esté activada, no es posible restablecer el
contador ni cambiar el valor preconfigurado.
3. Pantalla
—— Valor de conteo
—— Valor preconfigurado
Símbolo de salida activada
Indicador de valor
preconfigurado de corriente
4. Salida
Relé con contacto inversor libre de potencial u
optoacoplador con toma de corriente y emisor abiertos.
Se indicará la salida activada mediante I.
Para circuitos de seguridad, la operación del relé o del
optoacoplador se puede invertir. De este modo, la
bobina de relé se inactivará o el optoacoplador se
bloqueará al llegar al punto preconfigurado. Para esta
aplicación, la señal de salida Out 1 (Salida 1) debe
configurarse en
l
(señal permanente) o en
l
l
(señal
temporizada) durante la rutina de programación.
Precaución: En los modos de funcionamiento con
restablecimiento automático (AddAr, SubAr) se debe
programar la duración de la señal temporizada para la
salida, de lo contrario, la señal de salida no tendrá
duración definida (consulte Programación).
5. Configuración de los parámetros de
funcionamiento
a. Conecte el voltaje de suministro.
b. Coloque el conmutador DIP “A” (lado derecho de la
carcasa) en “ON” (encendido) durante un tiempo
breve. La pantalla mostrará el elemento del primer
menú “Modo”.
c. Seleccione la función necesaria mediante la tecla .
d. Presione la tecla P para almacenar la función
seleccionada/ingresar datos y para cambiar al
siguiente elemento del menú.
e. Seleccione la función que desee nuevamente con la
tecla para ingresar datos (factor de escala previa,
duración de la señal temporizada, tiempo de
cómputo, resolución) de forma directa mediante las
dos teclas de flecha.
f. Después de programar el último elemento del menú
(señal permanente o temporizada), saldrá de la
rutina de programación presionando la tecla P, si el
conmutador DIP “A” está en “OFF” (Apagado). Si
todavía está en “ON”, la rutina de programación
volverá a pasar una vez más.
ABCD
OFF
ON
10 MN05401009E
6. Configuración del modo de
funcionamiento
6.1 Selección de función básica
Después de que se ha encendido el conmutador DIP “A”
durante un tiempo breve, se mostrará una de las
funciones básicas del siguiente modo:
Rutina de
programación del
contador de
impulsos
Rutina de
programación
del
temporizador
Rutina de
programación del
medidor de
frecuencia
6.2.1 Rutina de programación del contador de
impulsos
Factor de escala:
0,0001…9,9999
Configuración con las teclas
y
No se aceptará el factor 0,0000
¡Precaución! En los modos de
funcionamiento Sub y SubAr
(señal de salida en el valor de
conteo = cero) el valor
preconfigurado debe ser
igualmente divisible por el factor;
de lo contrario, cuando — se
restablezca —el contador se
ajustará en el siguiente múltiplo
entero del factor.
Punto decimal
(sólo función óptica)
0 = sin punto decimal
0.0 = una cifra decimal
0.00 = dos cifras decimales
0.000 = tres cifras decimales
Señal permanente de la salida,
activada en el valor de conteo ≥
valor preconfigurado en el modo
de adición y en el valor de
conteo ≤ cero en el modo de
sustracción*
La señal permanente de la
salida, será pasiva en el valor de
conteo ≥ valor preconfigurado en
el modo de adición y en el valor
de conteo ≤ cero en el modo de
sustracción**
La señal temporizada de la
salida será pasiva en el valor de
conteo = valor preconfigurado en
el modo de adición y en el valor
de conteo = cero en el modo de
sustracción**
Señal temporizada de la salida,
activada en el valor de conteo =
valor preconfigurado en el modo
de adición y en el valor de
conteo = cero en el modo de
sustracción*
La duración de la señal
temporizada de la salida se
puede ajustar de 00,01 s a
99,99 s
* Activación de la bobina de relé
u optoacoplador al llegar al valor
preconfigurado
** La bobina de relé se inactivará
o el optoacoplador se bloqueará
al llegar al valor preconfigurado
Modo de funcionamiento Add:
Modo de adición
Señal permanente en el valor de
conteo ≥ valor preconfigurado o
señal temporizada en el valor de
conteo = valor preconfigurado
Restablecimiento en cero
Modo de funcionamiento Sub:
Modo de sustracción
Señal permanente en el valor de
conteo ≤
cero o señal temporizada
en el valor de conteo ≤
cero.
Restablezca el valor preconfigurado
Modo de funcionamiento AddAr:
Modo de adición
Señal temporizada en el valor de
conteo = valor preconfigurado
Restablecimiento automático en
cero
Modo de funcionamiento SubAr:
Modo de sustracción
Señal temporizada en el valor de
conteo = cero
Restablecimiento automático en el
valor preconfigurado
Polaridad de las entradas:
pospol: polaridad positiva (PNP)
modificación a + 24 V
negpol: polaridad negativa (NPN)
profundización a 0 V
Modos de entrada:
E1: ENT A = entrada de conteo
ENT B = entrada de dirección
de conteo
E2: ENT A = adición de entrada de
conteo
ENT B = sustracción de
entrada de conteo
E3: Entrada de cuadratura
ENT A = entrada de conteo 0°
ENT B = entrada de conteo
90°
E4: Igual que E3, pero con
duplicación de impulsos.
Se contará cada flanco del
impulso de la ENT A.
MN05401009E 11
español
Modo de funcionamiento Add:
Modo de adición
Señal permanente en el valor de
conteo ≥ valor preconfigurado o
señal temporizada en el valor de
conteo = valor preconfigurado
Restablecimiento en cero
Modo de funcionamiento Sub:
Modo de sustracción
Señal permanente en el valor de
conteo ≤ cero o señal
temporizada en el valor de
conteo = cero. Restablezca el
valor preconfigurado
Modo de funcionamiento
AddAr:
Modo de adición
Señal temporizada en el valor de
conteo = valor preconfigurado.
Restablecimiento automático en
cero
Modo de funcionamiento
SubAr:
Modo de sustracción
Señal temporizada en el valor de
conteo = cero
Restablecimiento automático en
el valor preconfigurado
Polaridad de las entradas:
pospol: polaridad positiva (PNP)
modificación a + 24 V
negpol: polaridad negativa
(NPN), profundización a 0 V
Unidad de tiempo:
Tiempo en segundos; 0,1 s; 0,01 s
o 0,001 s*
Tiempo en minutos; 0,1 min; 0,01
min* o 0,001 min*
Tiempo en horas; 0,1 h; 0,01 h
o 0,001 h*
* Dependiendo de la posición del
punto decimal
Tiempo en horas, minutos y
segundos
Punto decimal (resolución):
0 = sin punto decimal
0.0 = una cifra decimal
0.00 = dos cifras decimales
0.000 = tres cifras decimales
Señal permanente de la salida,
activada en el valor de conteo ≥
valor preconfigurado en el modo
de adición y en el valor de
conteo ≤ cero en el modo de
sustracción*
La señal permanente de la
salida, será pasiva en el valor
de conteo ≥ valor
preconfigurado en el modo de
adición y en el valor de conteo ≤
cero en el modo de
sustracción**
La señal temporizada de la
salida será pasiva en el valor de
conteo = valor preconfigurado
en el modo de adición y en el
valor de conteo = cero en el
modo de sustracción**
Señal temporizada de la salida,
activada en el valor de conteo =
valor preconfigurado en el modo
de adición y en el valor de
conteo = cero en el modo de
sustracción*
La duración de la señal
temporizada de la salida se
puede ajustar de 00,01 s
a 99,99 s
* Activación de la bobina de relé
u optoacoplador al llegar al
valor preconfigurado
** La bobina de relé se
inactivará o el optoacoplador se
bloqueará al llegar al valor
preconfigurado
6.2.2 Rutina de programación del
temporizador
12 MN05401009E
Tiempo de cómputo = dentro de
este período se contarán y
mostrarán los impulsos.
El rango programable es de 00,01
s a 99,99 s
Configuración con las teclas
y
00,00 no se aceptará
Polaridad de las entradas:
pospol: polaridad positiva (PNP)
sensor de modificación
negpol: polaridad negativa (NPN),
sensor de profundización
Modos de entrada:
E1: ENT A = entrada de conteo
ENT B = entrada de dirección
de conteo
E2: ENT A = adición de entrada de
conteo
ENT B = sustracción de
entrada de conteo
E3: Entrada de cuadratura
ENT A = entrada de conteo 0°
ENT B = entrada de conteo
90°
E4: Igual que E3, pero con
duplicación de impulsos.
Se contará cada flanco del
impulso de la ENT A.
Factor de escala:
0,0001…9,9999
Configuración con las teclas
y
No se aceptará el factor 0.0000
Punto decimal
(sólo función óptica):
0 = sin punto decimal
0.0 = una cifra decimal
0.00 = dos cifras decimales
0.000 = tres cifras decimales
Señal permanente de la salida,
activada en el valor de conteo ≥
valor preconfigurado*
La señal permanente de la salida
será pasiva en el valor de conteo
≥ valor preconfigurado**
La señal temporizada de la salida
será pasiva en el valor de conteo
= valor preconfigurado**
Señal temporizada de la salida,
activada en el valor de conteo =
valor preconfigurado*
La duración de la señal
temporizada de la salida se
puede ajustar de 00,01 s a
99,99 s
* Activación de la bobina de relé u
optoacoplador al llegar al valor
preconfigurado
** La bobina de relé se inactivará
o el optoacoplador se bloqueará
al llegar al valor preconfigurado
6.2.3 Rutina de programación del medidor de
frecuencia
MN05401009E 13
español
Configuración del sexto decimal
7. Programación del valor
preconfigurado:
Después de presionar una de las teclas de flecha, se
eliminará la supresión de cero inicial por
aproximadamente 4 segundos y el último dígito
importante de los valores preconfigurados destellará
con una frecuencia de 1 Hz.
El valor del digito que destella se puede aumentar con
la tecla
. Con la tecla cambiará al siguiente dígito.
Si no se presiona ninguna tecla durante 4 segundos, la
supresión del cero inicial se activará automáticamente
de nuevo.
En el modo de funcionamiento del contador de impulsos
y medidor de frecuencia se seleccionará el nuevo valor.
7.1 Configuración del signo
Seleccione el signo utilizando la tecla . El signo
comenzará a destellar ahora y se puede asignar un
valor preconfigurado o eliminar con la tecla .
Si no se presiona ninguna tecla durante 4 segundos, la
supresión del cero inicial se activará automáticamente
de nuevo. Ahora aparece el valor preconfigurado y el
valor de conteo con el signo correspondiente.
¡Precaución! En caso de restablecimiento automático,
no se configurará ningún valor negativo para el valor
preconfigurado.
8. Ejemplos de conexiones de
aplicaciones:
Impulsos de conteo del cierre del
contacto (polaridad programada PNP)
Impulsos de conteo de una barrera de luz
Impulsos de conteo de un codificador de eje
14 MN05401009E
9. Conexiones
9.1 Conexión de enchufe X1
¡Precaución! Para las configuraciones de
l
y
l
l
(funcionamiento inverso del relé u optoacoplador) las
conexiones del borne 4 y 5 cambian del siguiente modo:
Borne Versiones de CA y CC
4 contacto normalmente cerrado (NC) de salida
del relé
5 contacto normalmente abierto (NA) de salida
del relé
9.2 Conexión de enchufe X2
10. Datos técnicos
Voltaje de suministro:
90 – 260 V CA, 48 V CA, 24 V CA, 50/60
Hz, ±10 %, máx. 4 V A o 11 – 30 V CC,
máx. 0,1 A
Pantalla: Pantalla LCD de 7 segmentos, 2 líneas y
6 dígitos con signo
Caracteres de 9 mm [0,35 pulg.] de altura
para el valor de conteo
Caracteres de 7 mm [0,28 pulg.] de altura
para el valor preconfigurado
Símbolos para mostrar el contacto de
salida preconfigurado y cerrado
Polaridad de las señales de entrada:
Programable, todas las entradas en común
Sensibilidad de entrada:
Aprox. 10 kOhm
Frecuencia de conteo:
Mediante conmutadores DIP que se
pueden seleccionar por separado para ENT
A y ENT B
30 Hz
10 kHz (7 kHz para los modos de entrada
E3 y E4, entradas de cuadratura)
En caso de restablecimiento automático
900 Hz sin pérdidas de conteo (500 Hz
para el modo de entrada E4)
Duración mínima del impulso de las entradas de control:
5 ms
Sensibilidad de entrada:
Para voltajes de suministro de CA
Registro “0”: 0 – 4 V CC
Registro “1”: 12 – 30 V CC
Para voltaje de suministro de CC U
b
Registro “0”: 0 – 0.2 x U
b
Registro “1”: 0,6 x U
b
– 30 V CC
U
b
= Voltajes de suministro
Forma del impulso:
variable (característica de trigger de Schmitt)
Salida: Relé con contacto de trabajo o reposo libre
de potencial
Voltaje de conmutación máx. 250 V
AC/300 V CC
Corriente de conmutación máx. 3 A
Corriente de conmutación para CC mín.
30 mA
Rendimiento de conmutación máx. 50 W
para CC y máx. 2000 V A para CA
u
optoacoplador con toma de corriente y
emisor abiertos
Rendimiento de conmutación:
30 V CC/15 mA
V
ce sat
at I
c
= 15 mA: máx. 2,0 V
V
ce sat
at I
c
= 5 mA: máx. 0,4 V
Tiempo de respuesta de las salidas:
Relé: Aprox. 6 ms
Optoacoplador: Aprox. 1 ms
Retención de datos:
mín. 10 años o 10
6
ciclos de memoria
Voltaje del transmisor:
24 V CC –40 % / +15 %, 80 mA no
regulado para versiones de 24 y 48 V CA
24 V CC –40 % / +15 %, 100 mA no
regulado para versiones de 90 y 260 V CA
Borne Versión CA Versión CC
1 sin conexión
2 sin conexión
3 contacto común de salida del relé (C) emisor
de salida del optoacoplador
4 contacto normalmente abierto (NA) de salida
del relé
5 contacto normalmente cerrado (NC) de salida
del relé emisor de salida del optoacoplador
6 90 – 260 V CA/ 11 – 30 V CC
48 V/24 V CA Voltaje de
funcionamiento
7 90 – 260 V CA 0 V CC
48 V/24 V CA (Conex. a tierra)
Borne Designación Función Función
versión versión
230 V/115 V CA 11 – 30 V CC
48 V/24 V CA
1 + 24 V CC
Voltaje del
transmisor
2 Conex. a Voltaje de
tierra referencia
de 0 V CC
3 ENT A entrada de conteo A
4 ENT B entrada de conteo B
5 RESTABLE- entrada de restablecimiento
CIMIENTO
6 CÓMPUTO entrada de cómputo
7 TECLA entrada de bloqueo del teclado
MN05401009E 15
español
Protección de fusibles:
Fusible recomendado
Para CC: Retardo de tiempo de
0,125 A
Para 90 – 260 V C: Retardo de tiempo de
0,05 A
Para 48 V CA: Retardo de tiempo de
0,2 A
Para 24 V CA: Retardo de tiempo de
0,4 A
Inmunidad al ruido:
EN 55011 clase B y EN 50082-2 con
entradas de datos blindadas
Temperatura ambiente:
0 a 50° C [32 a 122° F]
Temperatura de almacenamiento:
-25 a 70° C [-13 a 158° F]
Peso: Aprox. 240 g [8,46 oz.]
(versión CA con relé)
Clasificación del panel delantero:
IP 65
Color de la carcasa:
Negra
Limpieza: La parte delantera de la unidad sólo se
debe limpiar con un paño suave
humedecido con agua.
11. Contenido:
– Contador
– Enchufe de bornes de tornillo, 7 polos, espaciado de
5,08 mm [0,2 pulg.]
– Enchufe de bornes de tornillo, 7 polos, espaciado de
3,81 mm [0,15 pulg.]
– Bísel para montaje con tornillos, plantilla de recorte del
panel de 50 x 50 mm [1,97 x 1,97 pulg.]
– Bísel para montaje con abrazadera, plantilla de recorte
del panel de 50 x 50 mm
[1,97 x 1,97 pulg.]
Abrazadera de montaje del panel
12. Código de pedido
E5148C142X
1 = 90 – 260 V CA
2 = 10 – 30 V CC
16 MN05401009E
Dimensiones en mm [pulgadas]:
Plantilla de recorte del panel de 45 x 45 [1,77 x 1,77]
Se muestra con la plantilla de recorte del panel de 50 x 50 [1,97 x 1,97] del bastidor delantero Nº 2
Se muestra con la plantilla de recorte del panel de 50 x 50 mm [1,97 x 1,97] del bastidor delantero Nº 3
Profundización
DIN 74
– Sujeto a cambios sin aviso previo –
48 [1,89]
55 [2,17]
60 [2,36]
48 [1,89]
55 [2,17]
75 [2,95]
86,5 [3,41]
85,5 [3,37]
85,5 [3,37]
15,5
[0,61]
15,5
[0,61]
15,5
[0,61]
3 [0,12]
4 [0,16]
4 [0,16]
máx. 10,5 [0,41]
máx. 9,5 [0,37]
45 [1,77]
45 [1.77]
45 [1,77]
63 [2,48]
50 [1.97]
50 [1.97]
máx. 9,5 [0,37]
MN05401009E 17
français
Notice de mise en service
du compteur éléctronique
à présélection E5148C142 Série
1. Description
– Compteur à 6 décades, add./soustrayant et à
1 présélection
– Double rangée dʼaffichage à LCD très lisible, avec
symboles pour lʼétat de la sortie
– Capacité de comptage et de présélections: de
–999999 à 999999. Dépassement de capacité sans
perte dʼimpulsions sur 1 décade; dans ce cas,
lʼaffichage clignote au rythme de 1 Hz
– Programmable en compteur horaire, dʼimpulsions ou
en fréquencemètre
– Sortie à relais ou optocoupleur
– La programmation des fonctions de comptage ou des
paramètres sʼéffectue au moyen des touches en
façade. Un guide utilisateur est actif à lʼaffichage
pendant la routine de programmation
– ProgrammableS sont:
Le mode (sortie active à zéro ou à la présélection,
avec ou sans répétition automatique)
Le point décimal
La polarité des entrées (NPN ou PNP)
Le type dʼentrée de comptage et la valeur du facteur
Le signal de sortie en fugitif ou en maintenu
La base de temps en fréquencemètre
La résolution en s, min, h ou h:min:s, en
comptage horaire
– Alimentation: 230, 115, 48, 24 VAC ou 11…30 VDC
2. Entrées
2.1 INP A, INP B
Entrées de comptage. La fréquence de comptage
maximale de ces 2 entrées est programmable à 30 Hz
ou 10 kHz, au moyen des commutateurs C et D (sur le
côté de lʼappareil).
2.2 Gate
Commande de porte statique. Pas de comptage tant
que cette entrée est activée.
Le point décimal situé entre la 5ème et la 6ème décade
clignote en mode comptage horaire lorsque la
commande de porte est inactive (témoin de marche en
h, min ou 0,1 min.).
2.3 Reset
En parallèle avec la touche rouge en façade, elle
repositionne le comptage à zéro en mode additionnant,
à la valeur de la présélection en mode soustrayant.
Micro
commut.
INP A INP B
30 Hz 10 kHz 30 Hz 10 kHz
D ON OFF
C ON OFF
ABCD
OFF
ON
2.4 Key
Entrée statique de verrouillage des touches. Tant
que cette entrée est activée, il est impossible de
repositionner le comptage ou de modifier la valeur
de la présélection (au moyen des touches).
3. Affichage
—— Comptage
—— Présélection
Sortie active
4. Sortie
Par contact relais inverseur (hors potentiel), ou par
optocoupleur à émetteur et collecteur ouverts.
La sortie active est affichée par le symbole. .
Pour des commutations de sécurité, il est possible
dʼinverser lʼactivation de la sortie, cʼest à dire, de
désactiver la bobine du relais ou de désaturer
lʼopto coupleur.
A cet effet, il convient de programmer le signal de sortie
OUT 1 en maintenu par
l
, en fugitif par
l
l
.
ATTENTION: Pour les modes avec répétition auto -
matique (AddAr, SubAr), la sortie doit être programmée
en mode fugitif, sinon cette dernière se retrouve dans un
état indéterminé (voir programmation).
5. Réglage des paramètres
a. Mettre lʼappareil sous tension
b. Commuter brièvement lʼinterrupteur «A» en position
«ON» (à droite du boîtier). Le point 1 «MODE» du
MENU est affiché.
c. Sélectionner la fonction voulue au moyen de la
touche .
d. La touche «P» permet de valider la fonction choisie
et de passer au pas de programmation suivant.
e. Continuer la sélection et la validation des fonctions
(facteur, durée de sortie fugitive, base de temps,
résolution), à lʼaide des 2 touches décrites ci-dessus.
f. Après la mise au point du dernier pas du MENU
(sortie maintenue ou fugitive), lʼappui de la touche
«P» clôt le paramètrage (à condition que le
commutateur «A» soit en position «OFF»). Dans le
cas contraire, le «MENU» de paramètrage reprend
au début.
ABCD
OFF
ON
18 MN05401009E
6. Sélection du mode de fonctionnement
6.1 Selection de la fonction primaire.
Un brève commutation de lʼinterrupteur «A» en «ON»,
donne lʼaffichage suivant:
Routine de
programmation
en compteur
dʼimpulsions
Routine de
programmation
en compteur
horaire
Routine de pro -
grammation en
fréquencemètre
6.2.1 Paramètrage en compteur dʼimpulsions
Facteur:
0,0001…9,9999
réglable par les touches et
Un facteur 0,0000 est refusé.
ATTENTION! en MODE Sub,
SubAR et la valeur de
prépositionnement doit être
divisible par le facteur (sans
décimale), sinon la valeur de
comptage est repositionnée à un
multiple du facteur.
Point décimal (uniq. visuel)
0 = pas de décimale
0,0 = 1 décimale
0,00 = 2 décimales
0,000 = 3 décimales
Sortie en maintenue, activée en
mode additionnant pour le
comptage ≥ à la consigne
1 et en mode soustrayant pour le
comptage ≤ à zéro*.
Sortie en maintenue, désactivée
en mode additionnant pour le
comptage ≥ à la consigne et en
mode soustrayant pour le
comptage ≤ zéro en mode
soustrayant**.
Sortie en fugitive, désactivée
lorsque le comptage = à la
consigne en mode additionnant
et le comptage = zéro en mode
soustrayant**.
Sortie en fugitive, activée lorsque
le comptage = à la consigne en
mode additionnant et le
comptage = zéro en mode
soustrayant*.
Durée du signal fugitif de la
sortie, règlable de 00,01 s à
99,99 s.
* A lʼatteinte de la consigne, la
bobine du relais est alimentée,
respectivement lʼoptocoupleur est
saturé.
** A lʼatteinte de la consigne, la
bobine du relais nʼest plus
alimentée, respectievement
lʼoptocoupleur est bloqueé.
Mode Add:
Comptage additionnant.
Signal maintenu pour comptage
≥ à la consigne ou signal fugitif
pour comptage = à la consigne.
Repositionnement à zéro.
Mode Sub:
Comptage soustrayant.
Signal maintenu pour comptage
≤ à zéro.
Signal fugitif pour comptage = à la
consigne.
Repositionnement à la valeur de la
consigne.
Mode Add Ar:
Comptage additionnant:
Signal fugitif pour comptage =
consigne.
Repositionnement automatique
à zéro.
Mode Sub Ar:
Comptage soustrayant:
Signal fugitif pour comptage = zéro.
Repositionnement automatique
à valeur de la consigne.
Polarité des entrées:
PoSPol; polarité positive (PNP),
commutant vers le +24 V.
nEGPoL; polarité négative (NPN),
commutant vers le +0 V.
Type dʼentrée:
E1: INP A = impulsions
INP B = sens de comptage
E2: INP A = impuls. additionnant
INP B = impuls. soustrayant
E3: Quadrature
INP A = impulsions 0°
INP B = impulsions 90°
E4: Idem à E3 avec multiplication
par 2 des impulsions.
Chaque front de INP A est pris
en compte
MN05401009E 19
français
Mode Add:
Comptage additionnant.
Signal maintenu pour comptage
≥ à la consigne ou signal fugitif
pour comptage = à la consigne.
Repositionnement à zéro.
Mode Sub:
Comptage soustrayant.
Signal maintenu pour comptage
≤ à la consigne ou signal fugitif
pour comptage = à la consigne.
Repositionnement à la valeur de
la consigne.
Mode Add Ar:
Comptage additionnant:
Signal fugitif pour comptage
= consigne.
Repositionnement automatique
à zéro.
Mode Sub Ar:
Comptage soustrayant:
Signal fugitif pour comptage
= consigne.
Repositionnement automatique
à valeur de la consigne.
Polarité des entrées
PoSPoL; polarité positive (PNP)
commutant vers le + 24 V.
nEGPoL; polarité négative (NPN),
commutant vers le 0 V.
Unité de mesure:
Comptage en s; 0,1 s; 0,01 s; ou
0,001 s*.
Comptage en min; 0,1 min;
0,01 min; ou 0,001 min*.
Comptage en h; 0,1 h; 0,01 h; ou
0,001 h*.
* selon la position décimale
Point décimal (résolution)
0 = pas de décimale
0,0 = 1 décimale
0,00 = 2 décimales
0,000 = 3 décimales
Sortie maintenue, activée en
mode additionnant pour le
comptage ≥ à la consigne et en
mode soustrayant pour le
comptage ≤ à zéro*.
Sortie maintenue, désactivée en
mode additionnant pur le
comptage ≥ à la consigne et en
mode soustrayant pour le
comptage ≤ à zéro**.
Sortie fugitive, désactivée lorsque
le comptage = à la consigne en
mode additionnant et le comptage
= zéro en mode soustrayant**.
Sortie fugitive, activée lorsque le
comptage = à la consigne en
mode additionnant et le comptage
= zéro en mode soustrayant*.
Durée du signal fugitif de la sortie,
règlable de 00,01 s à 99,99 s.
* A lʼatteinte de la consigne, la
bobine du relais est alimentée,
respectivement lʼoptocoupleur
est saturé.
** A lʼatteinte de la consigne, la
bobine du relais nʼest plus
alimentée, respectivement
lʼoptocoupleur est bloqué.
6.2.2 Paramètrage en compteur horaire
20 MN05401009E
Base de temps = Durée de
comptage des impulsions et
dʼintervalle de réactualisation de
lʼaffichage, règlable de 00,01 s à
99,99 s.
Programmation par les touches et
; une valeur 00,00 est refusée.
Polarité des entrées
PoSPoL; polarité positive (PNP),
commutant vers le + 24 V.
nEGPoL; polarité négative (NPN),
commutant vers le 0 V.
Type dʼentrée:
E1: INP A = impulsions
INP B = sens de comptage
E2: INP A = impuls. additionnant
INP B = impuls. soustrayant
E3: Quadrature
INP A = impulsions 0°
INP B = impulsions 90°
E4: Idem à E3 avec multiplication
par 2 des impulsions.
Chaque front de INP A est pris
en compte
Facteur:
0,0001…9,9999
règlable par les touches et
Un facteur 0,0000 est refusé.
Point décimal (uniq. visuel)
0 = pas de décimale
0,0 = 1 décimale
0,00 = 2 décimales
0,000 = 3 décimales
Sortie maintenue pour le
comptage ≥ à la consigne *.
Sortie maintenue pour le
comptage ≥ à la consigne**.
Sortie en fugitive, désactivée
lorsque le comptage = à la
consigne**.
Sortie du signal fugitive, activée
lorsque le comptage = à la
consigne*.
Durée du signal fugitif de la sortie,
réglable de 00,01 s à 99,99 s.
* A lʼatteinte de la consigne, la
bobine du relais est alimentée,
respectivement lʼoptocoupleur est
saturé.
** A lʼatteinte de la consigne, la
bobine du relais nʼest plus
alimentée, respectivement
lʼoptocoupleur est bloqué.
6.2.3 Paramètrage en fréquence
MN05401009E 21
français
Règlage de la 6ème décade
7. Reglage de la consigne:
Lʼactivation dʼune touche «flèche» désactive la
suppression des zéros pendant 4 secondes environ et la
décade des unités (à droite) de la présélection clignote
au rythme de 1 Hz.
La touche permet dʼincrémenter la décade clignotante.
La touche
etpermet de sélectionner la décade
supérieure. Après 4 secondes, si aucune des touches
déscrites ci-dessus nʼest activée la suppression des
zéros inutiles est remise en service. En mode compteur
dʼimpulsions ou fréquencemètre, la nouvelle valeur de
consigne est prise en compte.
7.1 Reglage du signe
La touche permet dʼactiver le signe; celui-ci apparait
en clignotant à gauche de la valeur de comptage. La
touche attribue ce signe à la consigne, le cas échéant,
le supprime.
4 secondes après lʼactivation dʼune touche, la
suppression des zéros inutiles est réactivée et la
consigne ainsi que la valeur de comptage sont affichés
avec le signe attribué.
ATTENTION: La valeur de la consigne ne doit pas être
négative lorque le mode «répétition automatique» est
actif!
8. Exemples de raccordements
Commande par contact et
une polarité en PNP
Commande par barrière de lumière
Commande par générateur dʼimpulsions
22 MN05401009E
9. Raccordements
9.1 Connecteur X1
Broche 230, 115, 48 11…30 VDC
Nr. ou 24 VAC
1 non reliée
2 non reliée
3 Sortie 2, commun du relais
Emetteur en optocoupleur
4 Sortie 2, contact travail du relais
5 Sortie 2, contact repos du relais
Collecteur en optocoupleur
6 230 VAC/115 VAC/ 11…30 VDC
48 VAC/24 VAC Alimentation
7 230 VAC/115 VAC 0 VDC (GND)
48 VAC/24 VAC
ATTENTION! Les raccordements différent lorsque les
sorties sont règlées en
l
ou en
l
l
.(inversion du mode
de commutation de la sortie)
Broche Versions AC et DC
Nr.
4 Sortie relais à ouverture NC
5 Sortie relais à fermeture NO
9.2 Connecteur X2
Broche Désignation Fonction Fonction
Nr. en 230, en
115, 48, 11…30 VDC
24 VAC
1 + 24 VDC
Aliment.
non
générat. raccordé
2 GND 0 VDC non
référen. raccordé
3 INP A ent. comptage A
4 INP B ent. comptage B
5 RESET entrée de repositionnement
6 GATE commande de porte
7 KEY ent. verrouillage des touches
10. Caractéristiques techniques
Alimentation:
230, 115, 48, 24 VAC, ± 10 %,
max. 4 VA
ou 11…30 VDC, max. 0,1 A
Affichage: 6 décades, 2 lignes, en 7 segments à LCD
avec signe. Comptage 9 mm, consigne
7 mm de hauteur. Symboles pour la sortie
active.
Polarité des entrées:
programmable; commune à toutes les
entrées
Résistance dʼentrée:
env. 10 kOhm
Fréquence de comptage:
règlable séparément par commutateurs
DIL, pour les entrées INP A et INP B
30 Hz
10 kHz (7 kHz en mode E3 ou E4,
quadrature)
900 Hz en répétition
automatique sans perte
dʼimpulsions (500 Hz en mode E4).
Durée minimale dʼimpulsions des entrées de commande:
5 ms
Niveau des entrées:
En alimentation AC;
Niv. «0»: 0…4 VDC
Niv. «1»: 12…30 VDC
En alimentation DC, U
b
Niv. «0»: 0…0,2 x U
b
Niv. «1»: 0,6 x U
b
–30 VDC
U
b
= Tension dʼalimentation
Forme des impulsions:
quelconque, Trigger de Schmitt
Sortie: Relais à contact inverseur
hors potentiel
Tension max. 250 VAC / 300 VDC
Courant max. 3 A
Courant min. en DC: 30 mA
Pouvoir de commutation max.:
50 W en DC, 2000 VA en VAC
ou
optocoupleur à émetteur et collecteur
ouvert
Pouvoir de commutation max.:
30 VDC / 15 mA
V
ce sat
pour I
c
= 15 mA: max. 2,0 V
V
ce sat
pour I
c
= 5 mA: max. 0,4 V
Temps de réponse de la sortie:
Relais: env. 6 ms
Optocoupleur: env. 1 ms
Sauvegarde des données:
min. 10 ans ou 10
6
cycles dʼécriture
Tension dʼémetteur:
24 V DC -40 % / + 15 %, 80 mA
non stabilisés en version AC24 et 48 V
24 V DC -40 % / + 15 %, 100 mA
non stabilisés enn version AC 90 – 280 V
MN05401009E 23
français
Fusible de protection:
en DC: 0,125 A temporisé
en 230 VAC: 0,05 A temporisé
en 115 VAC: 0,1 A temporisé
en 48 VAC: 0,2 A temporisé
en 24 VAC: 0,4 A temporisé
Insensibilité aux parasites:
EN 55011 classe B et
50082-2, avec câblage blindé
Température de service:
0…50°C
Température de stockage:
–25°C…+70°C
Poids: env. 240 g (en version AC et relais)
Protection: IP 65 par lʼavant
Teinte du boîtier:
noir
Nettoyage: La façade de lʼappareil peut être nettoyée
avec un chiffon doux humecté dʼeau.
11. Fournitures incluses à la livraison
– Compteur
– Connecteur à vis débrochable, 7 pôles,
écartement 5,08 mm
– Connecteur à vis débrochable, 7 pôles,
écartement 3,81 mm
– Cadre frontal à fixation par vis, découpe 50 x 50 mm
– Cadre frontal à fixation par étrier, découpe 50 x 50 mm
– Etrier de fixation
12. Codification de commande
E5148C142X
1 = 90 ... 260 V AC
2 = 10 ... 30 V DC
24 MN05401009E
Dimensions :
Découpe 45 x 45 mm
Montré avec cadre frontal Nr. 2
Découpe 50 x 50 mm
Montré avec cadre frontal Nr. 3
Découpe 50 x 50 mm
Fraisage Bf4
DIN 74
– Erreurs ou modifications réservées –
48 [1.89]
55 [2.17]
60 [2.36]
48 [1.89]
55 [2.17]
75 [2.95]
86.5 [3.41]
85.5 [3.37]
85.5 [3.37]
15.5
[0.61]
15.5
[0.61]
15.5
[0.61]
3 [0.12]
4 [0.16]
4 [0.16]
max. 10.5 [0.41]
max. 9.5 [0.37]
45 [1.77]
45 [1.77]
45 [1.77]
63 [2.48]
50 [1.97]
50 [1.97]
max. 9.5 [0.37]
MN05401009E 25
deutsch
Bedienungsanleitung R.600.300
Elektronischer Vorwahlzähler
E5148C142 Serie
1. Beschreibung
– 6stelliger add./subtr. Vorwahlzähler mit einer Vorwahl
– gut ablesbare 2-zeilige LCD-Anzeige mit Symbolen für
die angezeigte Vorwahl und den Zustand des
Ausgangs.
– Zähl- und Vorwahlbereich –999999 bis 999999
Über- oder Unterlauf ohne Zählverluste bis jeweils
1 Dekade, hierbei blinkt die Anzeige im s-Takt
– programmierbar als Impuls-, Frequenz- oder Zeit- bzw.
Betriebsstundenzähler
– Relais- oder Optokopplerausgang
– Die Programmierung der Zählfunktionen bzw. Be -
triebs para meter erfolgt über die Einstelltasten.
Bedienerführung auf dem Display während der Pro -
gram mier rou tine.
– programmierbar sind:
Betriebsart (Ausgangssignal bei Null oder Vorwahl,
mit oder ohne automat. Wiederholung)
Dezimalpunkt
Polarität der Eingänge (NPN oder PNP)
Eingangsart und Faktor
Ausgangssignal als Dauer- oder Wischsignal
Torzeit bei Programmierung als Frequenzzähler,
Auflösung in s, min, h oder h:min:s als Zeitzähler
– Spannungsversorgung 230 VAC, 115 VAC, 48 VAC,
24 VAC oder 11…30 VDC
2. Eingänge
2.1 INP A, INP B
Zähleingänge. Die max. Zählfrequenz dieser beiden
Eingänge ist über die Programmierschalter C und D (an
der rechten Seite des Zählergehäuses) auf 30 Hz oder
10 kHz einstellbar.
2.2 Gate
Statischer Toreingang; keine Zählung solange dieser
Eingang aktiviert ist.
In der Betriebsart Zeitzähler blinkt bei nichtaktiviertem
Toreingang der Dezimalpunkt zwischen der 5. und
6. Dekade (Laufanzeige bei Zeiteinheiten h, min oder
0,1 min).
2.3 Reset
Dynamischer Rücksetzeingang; er ist mit der roten Set-
Taste parallel geschaltet und setzt den Zähler bei add.
Zählweise auf Null, bei subtr. Zählweise auf den
Vorwahlwert.
Mikroschalter
INP A INP B
30 Hz 10 kHz 30 Hz 10 kHz
D ON OFF
C ON OFF
ABCD
OFF
ON
2.4 Key
Statischer Tastaturverriegelungseingang.
Solange dieser Eingang aktiviert ist, kann der Zähler
nicht zurückgesetzt oder die Vorwahl verändert werden.
3. Anzeige
—— Zählerstand
—— Vorwahlwert
Symbol für aktiven Ausgang
4. Ausgang
Relais mit potentialfreiem Wechselkontakt oder
Optokoppler mit offenem Emitter und Kollektor
Aktiver Ausgang wird auf dem Display mit 1
angezeigt
Für Sicherheitsschaltungen kann die Relais- bzw.
Optokoppleransteuerung invertiert werden, d.h. die
Relaisspule wird bei Erreichen der Vorwahl
spannungslos, bzw. der Optokoppler gesperrt.
Hierzu muß in der Programmierroutine das
Ausgangssignal Out1 bei Dauersignal auf
l
und bei
Wischsignal auf
l
l
eingestellt werden.
Achtung: Bei den Betriebsarten mit automatischer
Wiederholung (AddAr, SubAr) muß für den Ausgang
eine Wischzeit programmiert werden, da sonst das
Ausgangssignal keine definierte Länge hat (siehe
Programmierung).
5. Einstellung des Betriebsparameter
a. Spannungsversorgung einschalten
b. Programmierschalter „A“ (an der rechten Seite des
Zählergehäuses) kurzzeitig auf „ON“ stellen. Auf
dem Display wird der 1. Menüpunkt „Mode“
an gezeigt.
c. Mit der -Taste die gewünschte Funktion auswählen
d. Mit der P-Taste wird der eingestellte Wert
über nommen und auf den jeweiligen nächsten
Menüpunkt weitergeschaltet.
e. Erneut mit der -Taste die gewünschte Funktion
bzw. Zählerwerte (Faktor, Wisch- oder Torzeit, Auf -
lösung) direkt über die beiden Pfeiltasten eingeben.
f. Nach dem letzten Menüpunkt (Dauersignal oder
Wischsignal) wird mit der P-Taste die Programmier -
routine verlassen (Programmierschalter „A“ auf
„OFF“). Falls Schalter „A“ noch auf „ON“ geschaltet
ist, wird die Programmierroutine nochmals durch -
laufen.
ABCD
OFF
ON
26 MN05401009E
6. Einstellung der Betriebsart
6.1 Einstellung der Grundbetriebsart.
Nach kurzzeitigem Umschalten des Programmier -
schalters „A“ auf „ON“ erscheint eines der folgenden
Bilder auf dem Display:
Programmier-
routine
Impulszähler
Programmier-
routine
Zeitzähler
Programmier-
routine
Frequenzzähler
6.2.1 Programmierroutine Impulszähler
Faktor:
0,0001…9,9999
Einstellung mit den Tasten und
Faktor 0,0000 wird nicht
akzeptiert
Achtung! In den Betriebsarten
sub, sub Ar (Ausgangssignal bei
Zählerstand = Null) muß der
Vorwahlwert ganzzahlig durch
den Faktor teilbar sein,
andernfalls wird der Zähler bei
einem Reset auf das
nächstgrößere ganzzahlige
Vielfache des Faktors gesetzt.
Dezimalpunkt (nur anzeigend)
0 = keine Dezimalstelle
0,0 = 1 Dezimalstelle
0,00 = 2 Dezimalstellen
0,000 = 3 Dezimalstellen
Dauersignal des Ausgangs, wird
bei add. Zählung bei Zählerstand
≥ Vorwahl und bei subtr. Zählung
bei Zählerstand ≤ Null aktiv*
Dauersignal des Ausgangs, wird
bei add. Zählung bei Zählerstand
≥ Vorwahl und bei subtr. Zählung
bei Zählerstand ≤ Null passiv**
Wischsignal des Ausgangs, wird
bei add. Zählung bei Zählerstand
= Vorwahl und bei subtr. Zählung
bei Zählerstand = Null passiv**
Wischsignal des Ausgangs,wird
bei add. Zählung bei Zählerstand
= Vorwahl und bei subtr. Zählung
bei Zählerstand = Null aktiv*
Dauer des Wischsignals des
Ausgangs, einstellbar von 00,01 s
bis 99,99 s
* Relaisspule bzw. Optokoppler
werden bei Erreichen des
Vorwahlwertes angesteuert
** Relaisspule wird bei Erreichen
des Vorwahlwertes spannungslos
bzw. Optokoppler gesperrt.
Betriebsart Add:
Zähler arbeitet addierend
Dauersignal bei Zählerstand ≥
Vorwahl oder Wischsignal bei
Zählerstand ≥ Vorwahl
Reset auf Null
Betriebsart Sub:
Zähler arbeitet subtrahierend
Dauersignal bei Zählerstand ≤ Null
Wischsignal bei Zählerstand ≤ Null
Reset auf Vorwahl
Betriebsart Add Ar:
Zähler arbeitet addierend
Wischsignal bei Zählerstand =
Vorwahl
automatisches Nullsetzen
Betriebsart Sub Ar:
Zähler arbeitet subtrahierend
Wischsignal bei Zählerstand = Null
automatisches Setzen auf Vorwahl
Polarität der Eingänge
pospol: positive Polarität (PNP)
nach +24 V schaltend
negpol: negative Polarität (NPN)
nach 0V schaltend
Eingangsart:
E1: INP A = Zähleingang
INP B = Zählrichtungseingang
E2: INP A = Zähleingang add.
INP B = Zähleingang subtr.
E3: Quadratureingang
INP A = Zähleingang 0°
INP B = Zähleingang 90°
E4: wie E 3, jedoch mit Impuls -
verdoppelung.
Jede Flanke von INP A wird
gezählt
MN05401009E 27
deutsch
Betriebsart Add:
Zähler arbeitet addierend
Dauersignal bei Zählerstand ≥
Vorwahl oder Wischsignal bei
Zählerstand = Vorwahl
Reset auf Null
Betriebsart Sub:
Zähler arbeitet subtrahierend
Dauersignal bei Zählerstand ≤ Null
Wischsignal bei Zählerstand = Null
Reset auf Vorwahl
Betriebsart Add Ar:
Zähler arbeitet addierend
Wischsignal bei Zählerstand =
Vorwahl
automatisches Nullsetzen
Betriebsart Sub Ar:
Zähler arbeitet subtrahierend
Wischsignal bei Zählerstand =
Null
automatisches Setzen auf
Vorwahl
Polarität der Eingänge
pospol: positive Polarität (PNP),
nach +24 V schaltend
negpol: negative Polarität (NPN),
nach 0 V schaltend
Zeiteinheit:
Zählung in s; 0,1 s; 0,01 s oder
0,001 s*
Zählung in min; 0,1 min; 0,01
min*
oder 0,001 min
Zählung in h; 0,1 h; 0,01 h oder
0,001 h*
* je nach Stellung des Dezimal -
punktes
Zählung in h: min: s
Dezimalpunkt (Auflösung)
0 = keine Dezimalstelle
0,0 = 1 Dezimalstelle
0,00 = 2 Dezimalstellen
0,000 = 3 Dezimalstellen
Dauersignal des Ausgangs,wird
bei add. Zählung bei Zählerstand
≥ Vorwahl und bei subtr. Zählung
bei Zählerstand ≤ Null aktiv *
Dauersignal des Ausgangs,wird
bei add. Zählung bei Zählerstand
≥ Vorwahl und bei subtr. Zählung
bei Zählerstand ≤ Null passiv**
Wischsignal des Ausgangs,wird
bei add. Zählung bei Zählerstand
= Vorwahl und bei subtr. Zählung
bei Zählerstand = Null passiv**
Wischsignal des Ausgangs,wird
bei add. Zählung bei Zählerstand
= Vorwahl und bei subtr. Zählung
bei Zählerstand = Null aktiv*
Dauer des Wischsignals des
Ausgangs,einstellbar von 00,01s
bis 99,99 s
* Relaisspule bzw. Optokoppler
werden bei Erreichen des
Vorwahlwertes angesteuert
** Relaisspule wird bei Erreichen
des Vorwahlwertes
spannungslos bzw. Optokoppler
gesperrt.
6.2.2 Programmierroutine Zeitzähler
28 MN05401009E
Torzeit = Zeit, innerhalb der
eingehende Impulse gezählt und
zur Anzeige gebracht werden.
Einstellbereich von 00,01 s bis
99,99 s
Einstellung über die Tasten und
00,00 wird als Einstellung nicht
akzeptiert
Polarität der Eingänge
pospol: positive Polarität (PNP),
nach +24 V schaltend
negpol: negative Polarität (NPN),
nach 0 V schaltend
Eingangsart:
E1: INP A = Zähleingang
INP B = Zählrichtungseingang
E2: INP A = Zähleingang add.
INP B = Zähleingang subtr.
E3: Quadratureingang
INP A = Zähleingang 0°
INP B = Zähleingang 90°
E4: wie E 3, jedoch mit
Impulsverdoppelung.
Jede Flanke von INP A wird
gezählt
Faktor:
0,0001…9,9999
Einstellung mit den Tasten und
Faktor 0,0000 wird nicht akzeptiert
Dezimalpunkt (nur anzeigend)
0 = keine Dezimalstelle
0,0 = 1 Dezimalstelle
0,00 = 2 Dezimalstellen
0,000 = 3 Dezimalstellen
Dauersignal des Ausgangs, wird
bei Zählerstand ≥ Vorwahl aktiv *
Dauersignal des Ausgangs, wird
bei Zählerstand ≥ Vorwahl
passiv**
Wischsignal des Ausgangs, wird
bei Zählerstand = Vorwahl
passiv**
Wischsignal des Ausgangs, wird
bei Zählerstand = Vorwahl aktiv*
Dauer des Wischsignals des
Ausgangs, einstellbar von 00,01 s
bis 99,99 s
* Relaisspule bzw. Optokoppler
werden bei Erreichen des
Vorwahlwertes angesteuert
** Relaisspule wird bei Erreichen
des Vorwahlwertes spannungslos
bzw. Optokoppler gesperrt.
6.2.3 Programmierroutine Frequenzzähler
MN05401009E 29
deutsch
Einstellung in der 6. Dekade
7. Vorwahleinstellung:
Wird eine der Pfeiltasten betätigt, ist die
Vornullenunterdrückung ca. 4 Sekunden aufgehoben
und die rechte Dekade der Vorwahl blinkt im 1-Hz-
Rhythmus.
Mit der
-Taste wird der Wert der blinkenden Dekade in
steigender Reihenfolge verändert. Mit der
-Taste wird
die nächst höhere Dekade angewählt. 4 Sekunden nach
der letzten Tastenbetätigung wird automatisch die
Vornullenunterdrückung aktiv.
In den Betriebsarten Impulszähler und Frequenzzähler
wird jetzt der neue Wert übernommen.
7.1 Einstellung des Vorzeichens
Mit der -Taste das Vorzeichen anwählen; das
Vorzeichen erscheint blinkend vor dem aktuellen
Zählerstand. Mit der
-Taste wird das Vorzeichen dem
Vorwahlwert zugeordnet bzw. entfernt.
4 Sekunden nach der letzten Tastenbetätigung wird die
Vornullenunterdrückung aktiviert und Vorwahl und
Zählerstand mit dem entsprechenden Vorzeichen
an gezeigt.
Achtung: Bei automatischer Wiederholung dürfen keine
negativen Vorwahlwerte eingestellt werden!
8. Anschlußbeispiele
Ansteuerung über Kontakt
programmierte Polarität PNP
Ansteuerung über Lichtschranke
Ansteuerung über Drehgeber
30 MN05401009E
9. Anschlußbelegung
9.1 Steckerbelegung X1
Klemme AC-Version DC-Version
Nr.
1 nicht belegt
2 nicht belegt
3 Relaisausgang gemeinsamer Kontakt (C)
Optokopplerausgang Emitter
4 Relaisausgang Schließer (NO)
5 Relaisausgang Öffner (NC)
Optokopplerausgang Kollektor
6 90…260 VAC/ 11…30 VDC
48 VAC/24 VAC Betriebsspannung
7 90…260 VAC 0 VDC (GND)
48 VAC/24 VAC
Achtung! Bei Einstellung
l
und
l
l
(invertierte Relais-
oder Optokoppleransteuerung) ändern sich die
Anschlüsse der Klemmen 4 und 5
Klemme AC- und DC-Version
Nr.
4 Relaisausgang Öffner (NC)
5 Relaisausgang Schließer (NO)
9.2 Steckerbelegung X2
Klemme Benennung Funktion Funktion
Nr. 90…260 VAC 11…30 VDC-
48 VAC/24 VAC- Version
Version
1 + 24 VDC
Geberversorgungs-
nicht belegt
spannung
2 GND 0 VDC Bezugs- nicht belegt
spannung
3 INP A Zähleingang A
4 INP B Zähleingang B
5 RESET Rücksetzeingang
6 GATE Toreingang
7 KEY Tastaturverriegelungseingang
10. Technische Daten
Spannungsversorgung:
90…260 VAC, 48 VAC, 24 VAC,
50/60 Hz, ±10%,
max. 4 VA
oder 11…30 VDC,max. 0,1 A
Anzeige: 6stellige, 2zeilige 7-Segment-LCD-Anzeige
mit Vorzeichen
Istwert 9 mm hoch, Vorwahl 7 mm hoch
Symbole für angezeigte Vorwahl und
Ausgangskontakt geschlossen
Polarität der Eingangssignale:
programmierbar; für alle Eingänge
gemeinsam
Eingangswiderstand:
ca. 10 kOhm
Zählfrequenz:
über DIL-Schalter für INP A und INP B
separat einstellbar
30 Hz
10 kHz (7 kHz bei Eingangsart E3 und E4
Quadratureingang)
bei automatischer Wiederholung 900 Hz
ohne Zählverluste (500 Hz bei Eingangsart
E4)
Mindestimpulszeit der Steuereingänge:
5 ms
Schaltpegel der Eingänge:
Bei AC-Spannungsversorgung
Log „0“: 0… 4 VDC
Log „1“: 12…30 VDC
Bei DC-Spannungsversorgung U
b
Log „0“: 0…0,2 x U
b
Log „1“: 0,6 x U
b
…30 VDC
U
b
= Netzspannung
Impulsform: beliebig, da Schmitt-Trigger-Eingänge
Ausgang: Relais mit potentialfreiem Schaltkontakt,
Schaltspannung max. 250 VAC/300 VDC
Schaltstrom max. 3 A
Schaltstrom bei DC min. 30 mA
Schaltleistung max. 50 W bei DC
max. 2000 VA bei AC
oder
Optokoppler mit offenem Kollektor und
Emitter
Schaltleistung: 30 VDC/15 mA
V
ce sat
bei I
c
= 15 mA: max. 2,0 V
V
ce sat
bei I
c
= 5 mA: max. 0,4 V
Ansprechzeit des Ausgangs:
Relais: ca. 6 ms
Optokoppler: ca. 1 ms
Datensicherung:
min. 10 Jahre oder 10
6
Speicherzyklen
Geberspannung:
24 VDC –40% / +15%, 80 mA
unstabilisiert bei 24 + 48 VAC-Ausführung
24 VDC –40% / +15%, 100 mA
unstabilisiert bei 90…260 VAC-Ausführung
MN05401009E 31
deutsch
Absicherung:
empfohlene externe Sicherung
bei DC: 0,125 A, zeitverzögert
90…260 VAC: 0,05 A, zeitverzögert
bei 48 VAC: 0,2 A, zeitverzögert
bei 24 VAC: 0,4 A, zeitverzögert
Störfestigkeit:
EN 55011 Klasse B und EN 50082-2
mit geschirmten Dateneingängen
Umgebungstemperatur:
0…50°C
Lagertemperatur:
–25°C…+70°C
Gewicht: ca. 240 g (AC-Ausführung mit Relais)
Schutzart: IP 65 von vorne
Gehäusefarbe:
schwarz
Reinigung: Die Frontseite des Gerätes darf nur mit
einem weichen, mit Wasser angefeuchteten
Tuch gereinigt werden.
11. Lieferumfang
– Zähler
– Schraubsteckklemme 7polig, Rastermaß 5,08 mm
– Schraubsteckklemme 7polig, Rastermaß 3,81 mm
– Frontrahmen für Schraubbefestigung
Einbauquerschnitt 50 x 50 mm
– Frontrahmen für Spannbügelbefestigung
Einbauquerschnitt 50 x 50 mm
– Spannbügel
12. Bestellschlüssel
E5148C142X
1 = 90 ... 260 V AC
2 = 10 ... 30 V DC
© 2007 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. MN05401009E/CPG
March 2007
Eaton Corporation
Electrical Group
1000 Cherrington Parkway
Moon Township, PA 15108
United States
877-ETN CARE (877-386-2273)
Eaton.com
Maßbilder:
Einbauquerschnitt 45 x 45 mm
Mit Frontrahmen abgebildet Nr. 2
Einbauquerschnitt 50 x 50 mm
Mit Frontrahmen abgebildet Nr. 3
Einbauquerschnitt 50 x 50 mm
– Änderungen vorbehalten –
48 [1.89]
55 [2.17]
60 [2.36]
48 [1.89]
55 [2.17]
75 [2.95]
86.5 [3.41]
85.5 [3.37]
85.5 [3.37]
15.5
[0.61]
15.5
[0.61]
15.5
[0.61]
3 [0.12]
4 [0.16]
4 [0.16]
max. 10.5 [0.41]
max. 9.5 [0.37]
45 [1.77]
45 [1.77]
45 [1.77]
63 [2.48]
50 [1.97]
50 [1.97]
max. 9.5 [0.37]

Transcripción de documentos

Static keyboard lock input. While this input is activated, it is neither possible to reset the counter nor to change the preset value. Operating Instructions Electronic Preset Counter E5148C142 Series 3. Display —— count value 1. Description 2.1 INP A, INP B Count inputs; max. count frequency 30 Hz or 10 kHz separately selectable for both inputs via programming switches C and D at the right side of the housing. A B C D D C symbol for activated output français indicator for current preset value 4. Output deutsch Relay with potential free change-over contact or optocoupler with open collector and emitter. Activated output will be indicated by I. For safety circuits the operation of the relay, or the optocoupler may be inverted. Thus the relay coil will be dead, or the optocoupler will be locked when reaching the preset point. For this application, the output signal Out 1 must be set to –l– (permanent signal) or –l–l– (timed signal) during the programming routine. Caution: For operating modes with automatic reset (AddAr, SubAr) the duration of the timed signal for the output has to be programmed, otherwise the output signal has no defined duration (see programming). 5. Setting of the operating parameters a. connect to supply voltage 2. Inputs DIP switch español —— preset value – 6 digit preset counter, 1 preset, add./subtr. – bright 2-line LCD display with symbols for activated output and current preset value – count and preset range – 999999 to 999999, over- or underflow without count loss up to 1 decade (will be indicated by flashing of the display with 1 Hz frequency) – programmable to operate as a preset counter, timer or frequency meter – relay or optocoupler output – programming of count functions/operating parameters via the setting keys. During programming the display guides the user with text prompts. – programmable features: operating mode (output signal at zero or at preset point, with or without automatic reset) decimal point polarity of the inputs (NPN or PNP) input mode and scaling factor output signals to be permanent or timed gate time when programmed as a frequency meter resolution when programmed as a timer (s, min, h or h:min:s) – supply voltage 230V AC, 115V AC, 48V AC, 24V AC or 11 – 30V DC – backlit display (optional) OFF ON INP A 30 Hz 10 kHz ON OFF INP B 30 Hz 10 kHz ON OFF 2.2 Gate Static input; no counting while this input is activated. If operated as a timer (only h, min and 0.1 min resolutions), the decimal point between the 5th and 6th decade flashes while gate input is not activated (operating indication). b. set DIP switch “A” (right side of the housing) to “ON” for a short time. Display will show 1st menu item “Mode”. c. select required function via key d. press P-key to store selected function/enter data and to change over to next menu item. e. select the desired function again via key to enter data (prescaling factor, duration of timed signal, gate time, resolution) directly via the two arrow-keys. f. After programming the last menu item (permanent or timed signal), the programming routine will be exited by pressing the P-key, if DIP switch “A” is set to “OFF”. If it is still set to “ON”, the programming routine will be passed through once again. OFF ON A B C D 2.3 Reset Dynamic input; switched in parallel with the red set key and sets the counter to zero (adding mode) or to the preset value (subtracting mode). MN05401009E english 2.4 Key 1 6. Setting of the operating mode 6.1 Selection of basic function After DIP switch “A” has been switched to “ON” for a short time, one of the basic functions will be displayed as follows: programming routine Impulse Counter programming routine Timer programming routine Frequency Meter Scaling factor: 0.0001…9.9999 Setting with and keys Factor 0.0000 wonʼt be accepted Caution! In operating modes Sub and SubAr (output signal at count value = zero) the preset value has to be evenly divisible by the factor, otherwise the counter — when reset — will be set to the next integer multiple of the factor. Decimal point (only optical function) 0 = no decimal point 0.0 = one decimal place 0.00 = two decimal places 0.000 = three decimal places 6.2.1 Programming routine Impulse Counter Operating mode Add: Adding mode Permanent signal at count value ≥ preset value or timed signal at count value = preset value Reset to zero Operating mode Sub: Subtracting mode Permanent signal at count value ≤ zero or timed signal at count value ≤ zero. Reset to preset value Permanent signal of the output, activated at count value ≥ preset value in adding mode and at count value ≤ zero in subtracting mode* Permanent signal of the output, will become passive at count value ≥ preset value in adding mode and at count value ≤ zero in subtracting mode** Operating mode AddAr: Adding mode Timed signal at count value = preset value Automatic reset to zero Timed signal of the output, will become passive at count value = preset value in adding mode and at count value = zero in subtracting mode** Operating mode SubAr: Subtracting mode Timed signal at count value = zero Automatic reset to preset value Timed signal of the output, activated at count value = preset value in adding mode and at count value = zero in subtracting mode* Polarity of the inputs: pospol: positive polarity (PNP) sourcing from + 24V negpol: negative polarity (NPN) sinking to 0V Input modes: E1: INP A = count input INP B = count direction input Duration of timed signal of the output can be set from 00.01 s to 99.99 s * Activation of relay coil or optocoupler when reaching the preset value ** Relay coil becomes dead or optocoupler will be locked when reaching the preset value. E2: INP A = count input adding INP B = count input subtr. E3: Quadrature input INP A = count input 0° INP B = count input 90° E4: same as E3, but with pulse doubling. Each pulse edge of INP A will be counted. 2 MN05401009E Operating mode Add: Adding mode Permanent signal at count value ≥ preset value or timed signal at count value = preset value Reset to zero Operating mode Sub: Subtracting mode Permanent signal at count value ≤ zero or timed signal at count value = zero. Reset to preset value Operating mode AddAr: Adding mode Timed signal at count value = preset value. Automatic reset to zero Operating mode SubAr: Subtracting mode Timed signal at count value = zero Automatic reset to preset value Polarity of the inputs: pospol: positive polarity (PNP), soucing from + 24V negpol: negative polarity (NPN), sinking to 0V Permanent signal of the output, activated at count value ≥ preset value in adding mode and at count value ≤ zero in subtracting mode * Permanent signal of the output will become passive at count value ≥ preset value in adding mode and at count value ≤ zero in subtracting mode** Timed signal of the output, will become passive at count value = preset value in adding mode and at count value = zero in subtracting mode** Timed signal of the output, activated at count value = preset value in adding mode and at count value = zero in subtracting mode* Duration of timed signal of the output, can be set from 00.01s to 99.99 s. * Activation of relay coil or optocoupler when reaching the preset value ** Relay coil becomes dead or optocoupler will be locked when reaching the preset value. Unit of time: Timing in s; 0.1 s; 0.01 s or 0.001 s* Timing in min; 0.1 min; 0.01 min* or 0.001 min* Timing in h; 0.1 h; 0.01 h or 0.001 h* * depending on position of the decimal point Timing in h: min: s Decimal point (resolution): 0 = no decimal point 0.0 = one decimal place 0.00 = two decimal places 0.000 = three decimal places MN05401009E 3 english 6.2.2 Programming routine Timer 6.2.3 Programming routine Frequency Meter Gate time = within this period the incoming pulses will be counted and displayed. Programmable range from 00.01 s to 99.99 s Setting with and keys 00.00 wonʼt be accepted Polarity of the inputs: pospol: positive polarity (PNP), sourcing sensor Permanent signal of the output, activated at count value ≥ preset value* Permanent signal of the output, will become passive at count value ≥ preset value** Timed signal of the output, will become passive at count value = preset value** negpol: negative polarity (NPN), sinking sensor Timed signal of the output, activated at count value = preset value* Input modes: E1: INP A = count input INP B = count direction input E2: INP A = count input adding INP B = count input subtr. E3: Quadrature input INP A = count input 0° INP B = count input 90° E4: same as E3, but with pulse doubling. Each pulse edge of INP A will be counted. Duration of timed signal of the output can be set from 00.01 s to 99.99 s * Activation of relay coil or optocoupler when reaching the preset value ** Relay coil becomes dead or optocoupler will be locked when reaching the preset value. Scaling factor: 0.0001…9.9999 Setting with and keys Factor 0.0000 wonʼt be accepted Decimal point (only optical function): 0 = no decimal point 0.0 = one decimal place 0.00 = two decimal places 0.000 = three decimal places 4 MN05401009E 7. Programming of the Preset Value: 8. Examples for application connections: english After pressing one of the arrow keys, the leading zero blanking will be suppressed for approx. 4 seconds and the least significant digit of the preset value flashes with a frequency of 1 Hz. The value of the flashing digit can be increased by using the key. With the key it will be changed to the next digit. If no key is pressed for 4 seconds, the leading zero blanking will be activated automatically again. In operating mode Impulse Counter and Frequency Meter the new value will be selected. Caution! Do not change presets with output powered. Count pulses from contact closure (programmed polarity PNP) Setting of the 6th decade Count pulses from a light barrier 7.1 Setting of the sign Select the sign by using the key. The sign will start to flash now and can be assigned to the preset value or eliminated by using the key. If no key is pressed for 4 seconds, the leading zero blanking will be activated automatically again. Preset value and count value are displayed now with the corresponding sign. Intent of negative presets is to allow reset to a negative value. Caution! In case of automatic reset no negative values are to be set for the preset value. Count pulses from a shaft encoder MN05401009E 5 9. Connections 10. Technical Data Supply voltage: 90 – 260V AC, 48V AC, 24V AC, 50/60 Hz, ±10 %, max. 4 VA or 11 – 30V DC, max. 0.1 A Display: 6 digit, 2-line 7 segment LCD display with sign count value 9 mm [0.35 in.] high characters preset value 7 mm [0.28 in.] high characters symbols for displayed preset and closed output contact Polarity of input signals: programmable, all inputs in common Input sensitivity: approx. 10 kOhm 9.1 Plug connection X1 Terminal No. 1 2 3 4 5 6 7 AC version DC version no connection no connection relay output common contact (C) optocoupler output emitter relay output normally open contact (NO) relay output normally closed contact (NC) optocoupler output collector 90 – 260V AC/ 11 – 30V DC 48V/24V AC operating voltage 90 – 260V AC 0V DC (GND) 48V/24V AC Caution! For settings –l– and –l–l– (inverted operation of relay or optocoupler) the connections of terminal 4 and 5 change as follows: Terminal AC and DC versions No. 4 relay output normally closed contact (NC) 5 relay output normally open contact (NO) 9.2 Plug connection X2 Terminal Designation Function Function No. 230V/115V AC 11 – 30V DC 48V/24V AC version version 1 + 24V DC Transmitter voltage — 2 GND 0V DC reference — voltage 3 INP A count input A 4 INP B count input B 5 RESET reset input 6 GATE gate input 7 KEY keyboard lock input Count frequency: via DIP switches separately selectable for INP A and INP B 30 Hz 10 kHz (7 kHz for input modes E3 and E4, quadrature inputs) in case of automatic reset 900 Hz without count losses (500 Hz for input mode E4) Min. pulse length of the control inputs: 5 ms Input sensitivity: For AC supply voltages Log “0”: 0 – 4V DC Log “1”: 12 – 30V DC For DC supply voltage Ub Log “0”: 0 – 0.2 x Ub Log “1”: 0.6 x Ub – 30V DC Ub = Supply Voltage Pulse shape: variable (Schmitt Trigger characteristic) Output: Relay with potential free make or break contact switching voltage max. 250V AC / 300V DC switching current max. 3 A switching current for DC min. 30 mA switching performance max. 50W for DC and max. 2000 VA for AC or optocoupler with open collector and emitter switching performance: 30V DC/15 mA Vce sat at Ic = 15 mA: max. 2.0V Vce sat at Ic = 5 mA: max. 0.4V Responding time of outputs: Relay: approx. 6 ms Optocoupler: approx. 1 ms Data retention: min. 10 years or 106 memory cycles Transmitter voltage: 24V DC –40 % / +15 %, 80 mA unregulated for 24 and 48V AC-versions 24V DC –40 % / +15 %, 100 mA unregulated for 90 – 260V AC-versions 6 MN05401009E english Fuse protection: recommended fuse for DC: 0.125 A Time Delay for 90 – 260V AC: 0.05 A Time Delay for 48V AC: 0.2 A Time Delay for 24V AC: 0.4 A Time Delay Noise immunity: EN 55011 class B and EN 50082-2 with shielded data inputs Ambient temperature: 0 to 50°C [32 to 122°F] Storage temperature: -25 to 70°C [-13 to 158°F] Weight: approx. 240 g [8.46 oz.] (AC-version with relay) Front panel rating: IP 65 Color of housing: black Cleaning: The front of the unit is only to be cleaned with a soft cloth moistened with water. 11. Contents: – Counter – Screw terminal plug 7 poles, 5.08 mm [0.2 in] spacing – Screw terminal plug 7 poles, 3.81 mm [0.15 in.] spacing – Bezel for screw mount, panel cut-out 50 x 50 mm [1.97 x 1.97 in.] – Bezel for clip mount, panel cut-out 50 x 50 mm [1.97 x 1.97 in.] – Panel mounting clip 12. Ordering Code E5148C142X 1 = 90 – 260V AC 2 = 10 – 30V DC MN05401009E 7 Dimensions in mm [in.]: max. 10.5 [0.41] 48 [1.89] 45 [1.77] 48 [1.89] 86.5 [3.41] 55 [2.17] max. 9.5 [0.37] 50 [1.97] 45 [1.77] 55 [2.17] 3 [0.12] 15.5 [0.61] Panel cut-out 45 x 45 [1.77 x 1.77] 85.5 [3.37] Shown with front frame No. 2 panel cut-out 50 x 50 [1.97 x 1.97] 4 [0.16] 15.5 [0.61] 60 [2.36] 50 [1.97] 75 [2.95] 63 [2.48] 45 [1.77] max. 9.5 [0.37] 85.5 [3.37] Sinking 4 [0.16] DIN 74 Shown with front frame No. 3 panel cut-out 50 x 50 mm [1.97 x 1.97] 15.5 [0.61] – Subject to changes without prior notice – 8 MN05401009E 2.4 Tecla Instrucciones de operación Contador electrónico preconfigurado Serie E5148C142 Entrada de bloqueo del teclado estático. Mientras esta entrada esté activada, no es posible restablecer el contador ni cambiar el valor preconfigurado. 3. Pantalla —— Valor de conteo 1. Descripción 2. Entradas 2.1 ENTRADA A, ENTRADA B Entradas de conteo; frecuencia máxima de conteo de 30 Hz o 10 kHz que se pueden seleccionar por separado para ambas entradas mediante interruptores de programación C y D en el costado derecho de la cubierta. OFF ON A B C D Conmutador DIP D C ENT A 30 Hz 10 kHz ON OFF ENT B 30 Hz 10 kHz ON OFF 2.2 Cómputo Entrada estática; no se efectúa conteo mientras esta entrada está activada. Si se opera como temporizador (sólo resoluciones de horas, minutos y 0,1 minuto), el punto decimal entre el quinto y sexto decimal destella mientras la entrada de cómputo no está activada (indicación de funcionamiento). —— Valor preconfigurado español – Contador preconfigurado de 6 dígitos, 1 valor preconfigurado, adición/sustracción. – Pantalla LCD brillante de 2 líneas con símbolos para la salida activada y el valor preconfigurado de corriente. – Rango de conteo y preconfigurado (de – 999999 a 999999), sobre o bajo el flujo sin pérdidas de conteo de hasta 1 decimal (se indicará mediante destellos de la pantalla con una frecuencia de 1 Hz). – Programable para operar como un contador, temporizador o medidor de frecuencia preconfigurado. – Salida de relé u optoacoplador. – Programación de funciones de conteo/parámetros de operación por medio de las teclas de configuración. Durante la programación, la pantalla guía al usuario con indicaciones de texto. – Funciones programables: Modo de funcionamiento (señal de salida en cero o en un punto preconfigurado, con o sin restablecimiento automático) Punto decimal Polaridad de las entradas (NPN o PNP) Modo de entrada y factor de escala Señales de salida que serán permanentes o temporizadas Tiempo de cómputo cuando se programa como medidor de frecuencia Resolución cuando se programa como temporizador (s, min, h u h:min:s) – Voltaje de suministro 230 V CA, 115 V CA, 48 V CA, 24 V CA o 11 a 30 V CC – Pantalla con luz posterior (opcional) Símbolo de salida activada Indicador de valor preconfigurado de corriente 4. Salida Relé con contacto inversor libre de potencial u optoacoplador con toma de corriente y emisor abiertos. Se indicará la salida activada mediante I. Para circuitos de seguridad, la operación del relé o del optoacoplador se puede invertir. De este modo, la bobina de relé se inactivará o el optoacoplador se bloqueará al llegar al punto preconfigurado. Para esta aplicación, la señal de salida Out 1 (Salida 1) debe configurarse en –l– (señal permanente) o en –l–l– (señal temporizada) durante la rutina de programación. Precaución: En los modos de funcionamiento con restablecimiento automático (AddAr, SubAr) se debe programar la duración de la señal temporizada para la salida, de lo contrario, la señal de salida no tendrá duración definida (consulte Programación). 5. Configuración de los parámetros de funcionamiento a. Conecte el voltaje de suministro. b. Coloque el conmutador DIP “A” (lado derecho de la carcasa) en “ON” (encendido) durante un tiempo breve. La pantalla mostrará el elemento del primer menú “Modo”. c. Seleccione la función necesaria mediante la tecla . d. Presione la tecla P para almacenar la función seleccionada/ingresar datos y para cambiar al siguiente elemento del menú. e. Seleccione la función que desee nuevamente con la tecla para ingresar datos (factor de escala previa, duración de la señal temporizada, tiempo de cómputo, resolución) de forma directa mediante las dos teclas de flecha. f. Después de programar el último elemento del menú (señal permanente o temporizada), saldrá de la rutina de programación presionando la tecla P, si el conmutador DIP “A” está en “OFF” (Apagado). Si todavía está en “ON”, la rutina de programación volverá a pasar una vez más. OFF ON A B C D 2.3 Restablecimiento Entrada dinámica; entra en funcionamiento en paralelo con la tecla de configuración roja y ajusta el contador en cero (modo de adición) o en el valor preconfigurado (modo de sustracción). MN05401009E 9 6. Configuración del modo de funcionamiento 6.1 Selección de función básica Después de que se ha encendido el conmutador DIP “A” durante un tiempo breve, se mostrará una de las funciones básicas del siguiente modo: Rutina de programación del contador de impulsos Rutina de programación del temporizador Rutina de programación del medidor de frecuencia 6.2.1 Rutina de programación del contador de impulsos Modo de funcionamiento Add: Modo de adición Señal permanente en el valor de conteo ≥ valor preconfigurado o señal temporizada en el valor de conteo = valor preconfigurado Restablecimiento en cero Modo de funcionamiento Sub: Modo de sustracción Señal permanente en el valor de conteo ≤ cero o señal temporizada en el valor de conteo ≤ cero. Restablezca el valor preconfigurado Modo de funcionamiento AddAr: Modo de adición Señal temporizada en el valor de conteo = valor preconfigurado Restablecimiento automático en cero Modo de funcionamiento SubAr: Modo de sustracción Señal temporizada en el valor de conteo = cero Restablecimiento automático en el valor preconfigurado Polaridad de las entradas: pospol: polaridad positiva (PNP) modificación a + 24 V Factor de escala: 0,0001…9,9999 Configuración con las teclas y No se aceptará el factor 0,0000 ¡Precaución! En los modos de funcionamiento Sub y SubAr (señal de salida en el valor de conteo = cero) el valor preconfigurado debe ser igualmente divisible por el factor; de lo contrario, cuando — se restablezca —el contador se ajustará en el siguiente múltiplo entero del factor. Punto decimal (sólo función óptica) 0 = sin punto decimal 0.0 = una cifra decimal 0.00 = dos cifras decimales 0.000 = tres cifras decimales Señal permanente de la salida, activada en el valor de conteo ≥ valor preconfigurado en el modo de adición y en el valor de conteo ≤ cero en el modo de sustracción* La señal permanente de la salida, será pasiva en el valor de conteo ≥ valor preconfigurado en el modo de adición y en el valor de conteo ≤ cero en el modo de sustracción** La señal temporizada de la salida será pasiva en el valor de conteo = valor preconfigurado en el modo de adición y en el valor de conteo = cero en el modo de sustracción** Señal temporizada de la salida, activada en el valor de conteo = valor preconfigurado en el modo de adición y en el valor de conteo = cero en el modo de sustracción* negpol: polaridad negativa (NPN) profundización a 0 V Modos de entrada: E1: ENT A = entrada de conteo ENT B = entrada de dirección de conteo E2: ENT A = adición de entrada de conteo ENT B = sustracción de entrada de conteo La duración de la señal temporizada de la salida se puede ajustar de 00,01 s a 99,99 s * Activación de la bobina de relé u optoacoplador al llegar al valor preconfigurado ** La bobina de relé se inactivará o el optoacoplador se bloqueará al llegar al valor preconfigurado E3: Entrada de cuadratura ENT A = entrada de conteo 0° ENT B = entrada de conteo 90° E4: Igual que E3, pero con duplicación de impulsos. Se contará cada flanco del impulso de la ENT A. 10 MN05401009E 6.2.2 Rutina de programación del temporizador Modo de funcionamiento Sub: Modo de sustracción Señal permanente en el valor de conteo ≤ cero o señal temporizada en el valor de conteo = cero. Restablezca el valor preconfigurado Modo de funcionamiento AddAr: Modo de adición Señal temporizada en el valor de conteo = valor preconfigurado. Restablecimiento automático en cero Modo de funcionamiento SubAr: Modo de sustracción Señal temporizada en el valor de conteo = cero Restablecimiento automático en el valor preconfigurado Polaridad de las entradas: pospol: polaridad positiva (PNP) modificación a + 24 V negpol: polaridad negativa (NPN), profundización a 0 V Unidad de tiempo: Tiempo en segundos; 0,1 s; 0,01 s o 0,001 s* Señal permanente de la salida, activada en el valor de conteo ≥ valor preconfigurado en el modo de adición y en el valor de conteo ≤ cero en el modo de sustracción* La señal permanente de la salida, será pasiva en el valor de conteo ≥ valor preconfigurado en el modo de adición y en el valor de conteo ≤ cero en el modo de sustracción** La señal temporizada de la salida será pasiva en el valor de conteo = valor preconfigurado en el modo de adición y en el valor de conteo = cero en el modo de sustracción** Señal temporizada de la salida, activada en el valor de conteo = valor preconfigurado en el modo de adición y en el valor de conteo = cero en el modo de sustracción* La duración de la señal temporizada de la salida se puede ajustar de 00,01 s a 99,99 s * Activación de la bobina de relé u optoacoplador al llegar al valor preconfigurado ** La bobina de relé se inactivará o el optoacoplador se bloqueará al llegar al valor preconfigurado Tiempo en minutos; 0,1 min; 0,01 min* o 0,001 min* Tiempo en horas; 0,1 h; 0,01 h o 0,001 h* * Dependiendo de la posición del punto decimal Tiempo en horas, minutos y segundos Punto decimal (resolución): 0 = sin punto decimal 0.0 = una cifra decimal 0.00 = dos cifras decimales 0.000 = tres cifras decimales MN05401009E 11 español Modo de funcionamiento Add: Modo de adición Señal permanente en el valor de conteo ≥ valor preconfigurado o señal temporizada en el valor de conteo = valor preconfigurado Restablecimiento en cero 6.2.3 Rutina de programación del medidor de frecuencia Tiempo de cómputo = dentro de este período se contarán y mostrarán los impulsos. El rango programable es de 00,01 s a 99,99 s Configuración con las teclas y 00,00 no se aceptará Polaridad de las entradas: pospol: polaridad positiva (PNP) sensor de modificación negpol: polaridad negativa (NPN), sensor de profundización Señal permanente de la salida, activada en el valor de conteo ≥ valor preconfigurado* La señal permanente de la salida será pasiva en el valor de conteo ≥ valor preconfigurado** La señal temporizada de la salida será pasiva en el valor de conteo = valor preconfigurado** Señal temporizada de la salida, activada en el valor de conteo = valor preconfigurado* Modos de entrada: E1: ENT A = entrada de conteo ENT B = entrada de dirección de conteo E2: ENT A = adición de entrada de conteo ENT B = sustracción de entrada de conteo E3: Entrada de cuadratura ENT A = entrada de conteo 0° ENT B = entrada de conteo 90° E4: Igual que E3, pero con duplicación de impulsos. Se contará cada flanco del impulso de la ENT A. La duración de la señal temporizada de la salida se puede ajustar de 00,01 s a 99,99 s * Activación de la bobina de relé u optoacoplador al llegar al valor preconfigurado ** La bobina de relé se inactivará o el optoacoplador se bloqueará al llegar al valor preconfigurado Factor de escala: 0,0001…9,9999 Configuración con las teclas y No se aceptará el factor 0.0000 Punto decimal (sólo función óptica): 0 = sin punto decimal 0.0 = una cifra decimal 0.00 = dos cifras decimales 0.000 = tres cifras decimales 12 MN05401009E Después de presionar una de las teclas de flecha, se eliminará la supresión de cero inicial por aproximadamente 4 segundos y el último dígito importante de los valores preconfigurados destellará con una frecuencia de 1 Hz. El valor del digito que destella se puede aumentar con la tecla . Con la tecla cambiará al siguiente dígito. Si no se presiona ninguna tecla durante 4 segundos, la supresión del cero inicial se activará automáticamente de nuevo. En el modo de funcionamiento del contador de impulsos y medidor de frecuencia se seleccionará el nuevo valor. 8. Ejemplos de conexiones de aplicaciones: español 7. Programación del valor preconfigurado: Impulsos de conteo del cierre del contacto (polaridad programada PNP) Configuración del sexto decimal Impulsos de conteo de una barrera de luz 7.1 Configuración del signo Seleccione el signo utilizando la tecla . El signo comenzará a destellar ahora y se puede asignar un valor preconfigurado o eliminar con la tecla . Si no se presiona ninguna tecla durante 4 segundos, la supresión del cero inicial se activará automáticamente de nuevo. Ahora aparece el valor preconfigurado y el valor de conteo con el signo correspondiente. ¡Precaución! En caso de restablecimiento automático, no se configurará ningún valor negativo para el valor preconfigurado. Impulsos de conteo de un codificador de eje MN05401009E 13 9. Conexiones 10. Datos técnicos Voltaje de suministro: 90 – 260 V CA, 48 V CA, 24 V CA, 50/60 Hz, ±10 %, máx. 4 V A o 11 – 30 V CC, máx. 0,1 A Pantalla: Pantalla LCD de 7 segmentos, 2 líneas y 6 dígitos con signo Caracteres de 9 mm [0,35 pulg.] de altura para el valor de conteo Caracteres de 7 mm [0,28 pulg.] de altura para el valor preconfigurado Símbolos para mostrar el contacto de salida preconfigurado y cerrado Polaridad de las señales de entrada: Programable, todas las entradas en común 9.1 Conexión de enchufe X1 Borne Nº 1 2 3 4 5 6 7 Versión CA Versión CC sin conexión sin conexión contacto común de salida del relé (C) emisor de salida del optoacoplador contacto normalmente abierto (NA) de salida del relé contacto normalmente cerrado (NC) de salida del relé emisor de salida del optoacoplador 90 – 260 V CA/ 11 – 30 V CC 48 V/24 V CA Voltaje de funcionamiento 90 – 260 V CA 0 V CC 48 V/24 V CA (Conex. a tierra) ¡Precaución! Para las configuraciones de –l– y –l–l– (funcionamiento inverso del relé u optoacoplador) las conexiones del borne 4 y 5 cambian del siguiente modo: Borne Nº 4 5 Versiones de CA y CC contacto normalmente cerrado (NC) de salida del relé contacto normalmente abierto (NA) de salida del relé 9.2 Conexión de enchufe X2 Borne Nº 1 2 3 4 5 6 7 Designación Función Función versión versión 230 V/115 V CA 11 – 30 V CC 48 V/24 V CA + 24 V CC Voltaje del — transmisor Conex. a Voltaje de — tierra referencia de 0 V CC ENT A entrada de conteo A ENT B entrada de conteo B RESTABLE- entrada de restablecimiento CIMIENTO CÓMPUTO entrada de cómputo TECLA entrada de bloqueo del teclado Sensibilidad de entrada: Aprox. 10 kOhm Frecuencia de conteo: Mediante conmutadores DIP que se pueden seleccionar por separado para ENT A y ENT B 30 Hz 10 kHz (7 kHz para los modos de entrada E3 y E4, entradas de cuadratura) En caso de restablecimiento automático 900 Hz sin pérdidas de conteo (500 Hz para el modo de entrada E4) Duración mínima del impulso de las entradas de control: 5 ms Sensibilidad de entrada: Para voltajes de suministro de CA Registro “0”: 0 – 4 V CC Registro “1”: 12 – 30 V CC Para voltaje de suministro de CC Ub Registro “0”: 0 – 0.2 x Ub Registro “1”: 0,6 x Ub – 30 V CC Ub = Voltajes de suministro Forma del impulso: variable (característica de trigger de Schmitt) Salida: Relé con contacto de trabajo o reposo libre de potencial Voltaje de conmutación máx. 250 V AC / 300 V CC Corriente de conmutación máx. 3 A Corriente de conmutación para CC mín. 30 mA Rendimiento de conmutación máx. 50 W para CC y máx. 2000 V A para CA u optoacoplador con toma de corriente y emisor abiertos Rendimiento de conmutación: 30 V CC/15 mA Vce sat at Ic = 15 mA: máx. 2,0 V Vce sat at Ic = 5 mA: máx. 0,4 V Tiempo de respuesta de las salidas: Relé: Aprox. 6 ms Optoacoplador: Aprox. 1 ms Retención de datos: mín. 10 años o 106 ciclos de memoria Voltaje del transmisor: 24 V CC –40 % / +15 %, 80 mA no regulado para versiones de 24 y 48 V CA 24 V CC –40 % / +15 %, 100 mA no regulado para versiones de 90 y 260 V CA 14 MN05401009E Protección de fusibles: Fusible recomendado Para CC: Retardo de tiempo de 0,125 A Para 90 – 260 V C: Retardo de tiempo de 0,05 A Para 48 V CA: Retardo de tiempo de 0,2 A Para 24 V CA: Retardo de tiempo de 0,4 A español Inmunidad al ruido: EN 55011 clase B y EN 50082-2 con entradas de datos blindadas Temperatura ambiente: 0 a 50° C [32 a 122° F] Temperatura de almacenamiento: -25 a 70° C [-13 a 158° F] Peso: Aprox. 240 g [8,46 oz.] (versión CA con relé) Clasificación del panel delantero: IP 65 Color de la carcasa: Negra Limpieza: La parte delantera de la unidad sólo se debe limpiar con un paño suave humedecido con agua. 11. Contenido: – Contador – Enchufe de bornes de tornillo, 7 polos, espaciado de 5,08 mm [0,2 pulg.] – Enchufe de bornes de tornillo, 7 polos, espaciado de 3,81 mm [0,15 pulg.] – Bísel para montaje con tornillos, plantilla de recorte del panel de 50 x 50 mm [1,97 x 1,97 pulg.] – Bísel para montaje con abrazadera, plantilla de recorte del panel de 50 x 50 mm [1,97 x 1,97 pulg.] – Abrazadera de montaje del panel 12. Código de pedido E5148C142X 1 = 90 – 260 V CA 2 = 10 – 30 V CC MN05401009E 15 Dimensiones en mm [pulgadas]: máx. 10,5 [0,41] 48 [1,89] 45 [1,77] 48 [1,89] 86,5 [3,41] 3 [0,12] 15,5 [0,61] Plantilla de recorte del panel de 45 x 45 [1,77 x 1,77] 55 [2,17] 50 [1.97] 55 [2,17] 45 [1.77] máx. 9,5 [0,37] 85,5 [3,37] 4 [0,16] 15,5 [0,61] Se muestra con la plantilla de recorte del panel de 50 x 50 [1,97 x 1,97] del bastidor delantero Nº 2 60 [2,36] 50 [1.97] 75 [2,95] 63 [2,48] 45 [1,77] máx. 9,5 [0,37] 85,5 [3,37] Profundización DIN 74 4 [0,16] 15,5 [0,61] Se muestra con la plantilla de recorte del panel de 50 x 50 mm [1,97 x 1,97] del bastidor delantero Nº 3 – Sujeto a cambios sin aviso previo – 16 MN05401009E 2.4 Key Entrée statique de verrouillage des touches. Tant que cette entrée est activée, il est impossible de repositionner le comptage ou de modifier la valeur de la présélection (au moyen des touches). Notice de mise en service du compteur éléctronique à présélection E5148C142 Série 3. Affichage 1. Description 2.1 INP A, INP B Entrées de comptage. La fréquence de comptage maximale de ces 2 entrées est programmable à 30 Hz ou 10 kHz, au moyen des commutateurs C et D (sur le côté de lʼappareil). A B C D Micro commut. D C —— Présélection Sortie active 4. Sortie Par contact relais inverseur (hors potentiel), ou par optocoupleur à émetteur et collecteur ouverts. La sortie active est affichée par le symbole. . Pour des commutations de sécurité, il est possible dʼinverser lʼactivation de la sortie, cʼest à dire, de désactiver la bobine du relais ou de désaturer lʼoptocoupleur. A cet effet, il convient de programmer le signal de sortie OUT 1 en maintenu par –l– , en fugitif par –l–l–. ATTENTION: Pour les modes avec répétition automatique (AddAr, SubAr), la sortie doit être programmée en mode fugitif, sinon cette dernière se retrouve dans un état indéterminé (voir programmation). 5. Réglage des paramètres a. Mettre lʼappareil sous tension b. Commuter brièvement lʼinterrupteur «A» en position «ON» (à droite du boîtier). Le point 1 «MODE» du MENU est affiché. 2. Entrées OFF ON —— Comptage INP A 30 Hz 10 kHz ON OFF INP B 30 Hz 10 kHz ON OFF 2.2 Gate Commande de porte statique. Pas de comptage tant que cette entrée est activée. Le point décimal situé entre la 5ème et la 6ème décade clignote en mode comptage horaire lorsque la commande de porte est inactive (témoin de marche en h, min ou 0,1 min.). c. Sélectionner la fonction voulue au moyen de la touche . d. La touche «P» permet de valider la fonction choisie et de passer au pas de programmation suivant. e. Continuer la sélection et la validation des fonctions (facteur, durée de sortie fugitive, base de temps, résolution), à lʼaide des 2 touches décrites ci-dessus. f. Après la mise au point du dernier pas du MENU (sortie maintenue ou fugitive), lʼappui de la touche «P» clôt le paramètrage (à condition que le commutateur «A» soit en position «OFF»). Dans le cas contraire, le «MENU» de paramètrage reprend au début. OFF ON A B C D 2.3 Reset En parallèle avec la touche rouge en façade, elle repositionne le comptage à zéro en mode additionnant, à la valeur de la présélection en mode soustrayant. MN05401009E 17 français – Compteur à 6 décades, add./soustrayant et à 1 présélection – Double rangée dʼaffichage à LCD très lisible, avec symboles pour lʼétat de la sortie – Capacité de comptage et de présélections: de –999999 à 999999. Dépassement de capacité sans perte dʼimpulsions sur 1 décade; dans ce cas, lʼaffichage clignote au rythme de 1 Hz – Programmable en compteur horaire, dʼimpulsions ou en fréquencemètre – Sortie à relais ou optocoupleur – La programmation des fonctions de comptage ou des paramètres sʼéffectue au moyen des touches en façade. Un guide utilisateur est actif à lʼaffichage pendant la routine de programmation – ProgrammableS sont: Le mode (sortie active à zéro ou à la présélection, avec ou sans répétition automatique) Le point décimal La polarité des entrées (NPN ou PNP) Le type dʼentrée de comptage et la valeur du facteur Le signal de sortie en fugitif ou en maintenu La base de temps en fréquencemètre La résolution en s, min, h ou h:min:s, en comptage horaire – Alimentation: 230, 115, 48, 24 VAC ou 11…30 VDC 6. Sélection du mode de fonctionnement 6.1 Selection de la fonction primaire. Un brève commutation de lʼinterrupteur «A» en «ON», donne lʼaffichage suivant: Facteur: 0,0001…9,9999 réglable par les touches et Un facteur 0,0000 est refusé. ATTENTION ! en MODE Sub, SubAR et la valeur de prépositionnement doit être divisible par le facteur (sans décimale), sinon la valeur de comptage est repositionnée à un multiple du facteur. Routine de programmation en compteur dʼimpulsions Routine de programmation en compteur horaire Routine de programmation en fréquencemètre 6.2.1 Paramètrage en compteur dʼimpulsions Mode Add: Comptage additionnant. Signal maintenu pour comptage ≥ à la consigne ou signal fugitif pour comptage = à la consigne. Repositionnement à zéro. Mode Sub: Comptage soustrayant. Signal maintenu pour comptage ≤ à zéro. Signal fugitif pour comptage = à la consigne. Repositionnement à la valeur de la consigne. Mode Add Ar: Comptage additionnant: Signal fugitif pour comptage = consigne. Repositionnement automatique à zéro. Mode Sub Ar: Comptage soustrayant: Signal fugitif pour comptage = zéro. Repositionnement automatique à valeur de la consigne. Polarité des entrées: PoSPol; polarité positive (PNP), commutant vers le +24 V. nEGPoL; polarité négative (NPN), commutant vers le +0 V. Type dʼentrée: E1: INP A = impulsions INP B = sens de comptage E2: INP A = impuls. additionnant INP B = impuls. soustrayant Point décimal (uniq. visuel) 0 = pas de décimale 0,0 = 1 décimale 0,00 = 2 décimales 0,000 = 3 décimales Sortie en maintenue, activée en mode additionnant pour le comptage ≥ à la consigne 1 et en mode soustrayant pour le comptage ≤ à zéro*. Sortie en maintenue, désactivée en mode additionnant pour le comptage ≥ à la consigne et en mode soustrayant pour le comptage ≤ zéro en mode soustrayant**. Sortie en fugitive, désactivée lorsque le comptage = à la consigne en mode additionnant et le comptage = zéro en mode soustrayant**. Sortie en fugitive, activée lorsque le comptage = à la consigne en mode additionnant et le comptage = zéro en mode soustrayant*. Durée du signal fugitif de la sortie, règlable de 00,01 s à 99,99 s. * A lʼatteinte de la consigne, la bobine du relais est alimentée, respectivement lʼoptocoupleur est saturé. ** A lʼatteinte de la consigne, la bobine du relais nʼest plus alimentée, respectievement lʼoptocoupleur est bloqueé. E3: Quadrature INP A = impulsions 0° INP B = impulsions 90° E4: Idem à E3 avec multiplication par 2 des impulsions. Chaque front de INP A est pris en compte 18 MN05401009E 6.2.2 Paramètrage en compteur horaire Mode Sub: Comptage soustrayant. Signal maintenu pour comptage ≤ à la consigne ou signal fugitif pour comptage = à la consigne. Repositionnement à la valeur de la consigne. Mode Add Ar: Comptage additionnant: Signal fugitif pour comptage = consigne. Repositionnement automatique à zéro. Sortie maintenue, activée en mode additionnant pour le comptage ≥ à la consigne et en mode soustrayant pour le comptage ≤ à zéro*. Sortie maintenue, désactivée en mode additionnant pur le comptage ≥ à la consigne et en mode soustrayant pour le comptage ≤ à zéro**. Sortie fugitive, désactivée lorsque le comptage = à la consigne en mode additionnant et le comptage = zéro en mode soustrayant**. Sortie fugitive, activée lorsque le comptage = à la consigne en mode additionnant et le comptage = zéro en mode soustrayant*. Mode Sub Ar: Comptage soustrayant: Signal fugitif pour comptage = consigne. Repositionnement automatique à valeur de la consigne. Durée du signal fugitif de la sortie, règlable de 00,01 s à 99,99 s. Polarité des entrées PoSPoL; polarité positive (PNP) commutant vers le + 24 V. ** A lʼatteinte de la consigne, la bobine du relais nʼest plus alimentée, respectivement lʼoptocoupleur est bloqué. * A lʼatteinte de la consigne, la bobine du relais est alimentée, respectivement lʼoptocoupleur est saturé. nEGPoL; polarité négative (NPN), commutant vers le 0 V. Unité de mesure: Comptage en s; 0,1 s; 0,01 s; ou 0,001 s*. Comptage en min; 0,1 min; 0,01 min; ou 0,001 min*. Comptage en h; 0,1 h; 0,01 h; ou 0,001 h*. * selon la position décimale Point décimal (résolution) 0 = pas de décimale 0,0 = 1 décimale 0,00 = 2 décimales 0,000 = 3 décimales MN05401009E 19 français Mode Add: Comptage additionnant. Signal maintenu pour comptage ≥ à la consigne ou signal fugitif pour comptage = à la consigne. Repositionnement à zéro. 6.2.3 Paramètrage en fréquence Base de temps = Durée de comptage des impulsions et dʼintervalle de réactualisation de lʼaffichage, règlable de 00,01 s à 99,99 s. Programmation par les touches et ; une valeur 00,00 est refusée. Polarité des entrées PoSPoL; polarité positive (PNP), commutant vers le + 24 V. nEGPoL; polarité négative (NPN), commutant vers le 0 V. Type dʼentrée: E1: INP A = impulsions INP B = sens de comptage Sortie maintenue pour le comptage ≥ à la consigne *. Sortie maintenue pour le comptage ≥ à la consigne**. Sortie en fugitive, désactivée lorsque le comptage = à la consigne**. Sortie du signal fugitive, activée lorsque le comptage = à la consigne*. Durée du signal fugitif de la sortie, réglable de 00,01 s à 99,99 s. E2: INP A = impuls. additionnant INP B = impuls. soustrayant E3: Quadrature INP A = impulsions 0° INP B = impulsions 90° E4: Idem à E3 avec multiplication par 2 des impulsions. Chaque front de INP A est pris en compte * A lʼatteinte de la consigne, la bobine du relais est alimentée, respectivement lʼoptocoupleur est saturé. ** A lʼatteinte de la consigne, la bobine du relais nʼest plus alimentée, respectivement lʼoptocoupleur est bloqué. Facteur: 0,0001…9,9999 règlable par les touches et Un facteur 0,0000 est refusé. Point décimal (uniq. visuel) 0 = pas de décimale 0,0 = 1 décimale 0,00 = 2 décimales 0,000 = 3 décimales 20 MN05401009E 7. Reglage de la consigne: 8. Exemples de raccordements Lʼactivation dʼune touche «flèche» désactive la suppression des zéros pendant 4 secondes environ et la décade des unités (à droite) de la présélection clignote au rythme de 1 Hz. La touche permet dʼincrémenter la décade clignotante. La touche etpermet de sélectionner la décade supérieure. Après 4 secondes, si aucune des touches déscrites ci-dessus nʼest activée la suppression des zéros inutiles est remise en service. En mode compteur dʼimpulsions ou fréquencemètre, la nouvelle valeur de consigne est prise en compte. Commande par contact et une polarité en PNP français Règlage de la 6ème décade 7.1 Reglage du signe La touche permet dʼactiver le signe; celui-ci apparait en clignotant à gauche de la valeur de comptage. La touche attribue ce signe à la consigne, le cas échéant, le supprime. 4 secondes après lʼactivation dʼune touche, la suppression des zéros inutiles est réactivée et la consigne ainsi que la valeur de comptage sont affichés avec le signe attribué. ATTENTION: La valeur de la consigne ne doit pas être négative lorque le mode «répétition automatique» est actif ! Commande par barrière de lumière Commande par générateur dʼimpulsions MN05401009E 21 9. Raccordements 10. Caractéristiques techniques Alimentation: 230, 115, 48, 24 VAC, ± 10 %, max. 4 VA ou 11…30 VDC, max. 0,1 A Affichage: 6 décades, 2 lignes, en 7 segments à LCD avec signe. Comptage 9 mm, consigne 7 mm de hauteur. Symboles pour la sortie active. Polarité des entrées: programmable; commune à toutes les entrées Résistance dʼentrée: env. 10 kOhm 9.1 Connecteur X1 Broche Nr. 1 2 3 4 5 6 7 230, 115, 48 11…30 VDC ou 24 VAC non reliée non reliée Sortie 2, commun du relais Emetteur en optocoupleur Sortie 2, contact travail du relais Sortie 2, contact repos du relais Collecteur en optocoupleur 230 VAC/115 VAC/ 11…30 VDC 48 VAC/24 VAC Alimentation 230 VAC/115 VAC 0 VDC (GND) 48 VAC/24 VAC ATTENTION! Les raccordements différent lorsque les sorties sont règlées en –l– ou en –l–l–.(inversion du mode de commutation de la sortie) Broche Versions AC et DC Nr. 4 Sortie relais à ouverture NC 5 Sortie relais à fermeture NO 9.2 Connecteur X2 Broche Désignation Fonction Fonction Nr. en 230, en 115, 48, 11…30 VDC 24 VAC 1 + 24 VDC Aliment. non générat. raccordé 2 GND 0 VDC non référen. raccordé 3 INP A ent. comptage A 4 INP B ent. comptage B 5 RESET entrée de repositionnement 6 GATE commande de porte 7 KEY ent. verrouillage des touches Fréquence de comptage: règlable séparément par commutateurs DIL, pour les entrées INP A et INP B 30 Hz 10 kHz (7 kHz en mode E3 ou E4, quadrature) 900 Hz en répétition automatique sans perte dʼimpulsions (500 Hz en mode E4). Durée minimale dʼimpulsions des entrées de commande: 5 ms Niveau des entrées: En alimentation AC; Niv. «0»: 0…4 VDC Niv. «1»: 12…30 VDC En alimentation DC, Ub Niv. «0»: 0…0,2 x Ub Niv. «1»: 0,6 x Ub–30 VDC Ub = Tension dʼalimentation Forme des impulsions: quelconque, Trigger de Schmitt Sortie: Relais à contact inverseur hors potentiel Tension max. 250 VAC / 300 VDC Courant max. 3 A Courant min. en DC: 30 mA Pouvoir de commutation max.: 50 W en DC, 2000 VA en VAC ou optocoupleur à émetteur et collecteur ouvert Pouvoir de commutation max.: 30 VDC / 15 mA Vce sat pour Ic = 15 mA: max. 2,0 V Vce sat pour Ic = 5 mA: max. 0,4 V Temps de réponse de la sortie: Relais: env. 6 ms Optocoupleur: env. 1 ms Sauvegarde des données: min. 10 ans ou 106 cycles dʼécriture Tension dʼémetteur: 24 V DC -40 % / + 15 %, 80 mA non stabilisés en version AC24 et 48 V 24 V DC -40 % / + 15 %, 100 mA non stabilisés enn version AC 90 – 280 V 22 MN05401009E Fusible de protection: en DC: en 230 VAC: en 115 VAC: en 48 VAC: en 24 VAC: 0,125 A temporisé 0,05 A temporisé 0,1 A temporisé 0,2 A temporisé 0,4 A temporisé Insensibilité aux parasites: EN 55011 classe B et 50082-2, avec câblage blindé Température de service: 0…50°C Température de stockage: –25°C…+70°C Poids: env. 240 g (en version AC et relais) Protection: IP 65 par lʼavant français Teinte du boîtier: noir Nettoyage: La façade de lʼappareil peut être nettoyée avec un chiffon doux humecté dʼeau. 11. Fournitures incluses à la livraison – Compteur – Connecteur à vis débrochable, 7 pôles, écartement 5,08 mm – Connecteur à vis débrochable, 7 pôles, écartement 3,81 mm – Cadre frontal à fixation par vis, découpe 50 x 50 mm – Cadre frontal à fixation par étrier, découpe 50 x 50 mm – Etrier de fixation 12. Codification de commande E5148C142X 1 = 90 ... 260 V AC 2 = 10 ... 30 V DC MN05401009E 23 Dimensions : max. 10.5 [0.41] 48 [1.89] 45 [1.77] 48 [1.89] 86.5 [3.41] 3 [0.12] 15.5 [0.61] Découpe 45 x 45 mm 55 [2.17] 50 [1.97] 55 [2.17] 45 [1.77] max. 9.5 [0.37] 85.5 [3.37] Montré avec cadre frontal Nr. 2 Découpe 50 x 50 mm 4 [0.16] 15.5 [0.61] 60 [2.36] Fraisage Bf4 DIN 74 Montré avec cadre frontal Nr. 3 Découpe 50 x 50 mm 50 [1.97] 75 [2.95] 63 [2.48] 45 [1.77] max. 9.5 [0.37] 85.5 [3.37] 4 [0.16] 15.5 [0.61] – Erreurs ou modifications réservées – 24 MN05401009E 2.4 Key Bedienungsanleitung Elektronischer Vorwahlzähler E5148C142 Serie R.600.300 Statischer Tastaturverriegelungseingang. Solange dieser Eingang aktiviert ist, kann der Zähler nicht zurückgesetzt oder die Vorwahl verändert werden. 3. Anzeige —— Zählerstand 1. Beschreibung Zähleingänge. Die max. Zählfrequenz dieser beiden Eingänge ist über die Programmierschalter C und D (an der rechten Seite des Zählergehäuses) auf 30 Hz oder 10 kHz einstellbar. Relais mit potentialfreiem Wechselkontakt oder Optokoppler mit offenem Emitter und Kollektor Aktiver Ausgang wird auf dem Display mit 1 angezeigt Für Sicherheitsschaltungen kann die Relais- bzw. Optokoppleransteuerung invertiert werden, d.h. die Relaisspule wird bei Erreichen der Vorwahl spannungslos, bzw. der Optokoppler gesperrt. Hierzu muß in der Programmierroutine das Ausgangssignal Out1 bei Dauersignal auf –l– und bei Wischsignal auf –l–l– eingestellt werden. Achtung: Bei den Betriebsarten mit automatischer Wiederholung (AddAr, SubAr) muß für den Ausgang eine Wischzeit programmiert werden, da sonst das Ausgangssignal keine definierte Länge hat (siehe Programmierung). b. Programmierschalter „A“ (an der rechten Seite des Zählergehäuses) kurzzeitig auf „ON“ stellen. Auf dem Display wird der 1. Menüpunkt „Mode“ angezeigt. c. Mit der A B C D D C 4. Ausgang a. Spannungsversorgung einschalten 2.1 INP A, INP B Mikroschalter Symbol für aktiven Ausgang 5. Einstellung des Betriebsparameter 2. Eingänge OFF ON —— Vorwahlwert deutsch – 6stelliger add./subtr. Vorwahlzähler mit einer Vorwahl – gut ablesbare 2-zeilige LCD-Anzeige mit Symbolen für die angezeigte Vorwahl und den Zustand des Ausgangs. – Zähl- und Vorwahlbereich –999999 bis 999999 Über- oder Unterlauf ohne Zählverluste bis jeweils 1 Dekade, hierbei blinkt die Anzeige im s-Takt – programmierbar als Impuls-, Frequenz- oder Zeit- bzw. Betriebsstundenzähler – Relais- oder Optokopplerausgang – Die Programmierung der Zählfunktionen bzw. Betriebsparameter erfolgt über die Einstelltasten. Bedienerführung auf dem Display während der Programmierroutine. – programmierbar sind: Betriebsart (Ausgangssignal bei Null oder Vorwahl, mit oder ohne automat. Wiederholung) Dezimalpunkt Polarität der Eingänge (NPN oder PNP) Eingangsart und Faktor Ausgangssignal als Dauer- oder Wischsignal Torzeit bei Programmierung als Frequenzzähler, Auflösung in s, min, h oder h:min:s als Zeitzähler – Spannungsversorgung 230 VAC, 115 VAC, 48 VAC, 24 VAC oder 11…30 VDC INP A 30 Hz 10 kHz ON OFF INP B 30 Hz 10 kHz ON OFF 2.2 Gate Statischer Toreingang; keine Zählung solange dieser Eingang aktiviert ist. In der Betriebsart Zeitzähler blinkt bei nichtaktiviertem Toreingang der Dezimalpunkt zwischen der 5. und 6. Dekade (Laufanzeige bei Zeiteinheiten h, min oder 0,1 min). -Taste die gewünschte Funktion auswählen d. Mit der P-Taste wird der eingestellte Wert übernommen und auf den jeweiligen nächsten Menüpunkt weitergeschaltet. e. Erneut mit der -Taste die gewünschte Funktion bzw. Zählerwerte (Faktor, Wisch- oder Torzeit, Auflösung) direkt über die beiden Pfeiltasten eingeben. f. Nach dem letzten Menüpunkt (Dauersignal oder Wischsignal) wird mit der P-Taste die Programmierroutine verlassen (Programmierschalter „A“ auf „OFF“). Falls Schalter „A“ noch auf „ON“ geschaltet ist, wird die Programmierroutine nochmals durchlaufen. OFF ON A B C D 2.3 Reset Dynamischer Rücksetzeingang; er ist mit der roten SetTaste parallel geschaltet und setzt den Zähler bei add. Zählweise auf Null, bei subtr. Zählweise auf den Vorwahlwert. MN05401009E 25 6. Einstellung der Betriebsart 6.1 Einstellung der Grundbetriebsart. Nach kurzzeitigem Umschalten des Programmierschalters „A“ auf „ON“ erscheint eines der folgenden Bilder auf dem Display: Programmierroutine Impulszähler Programmierroutine Zeitzähler Programmierroutine Frequenzzähler 6.2.1 Programmierroutine Impulszähler Betriebsart Add: Zähler arbeitet addierend Dauersignal bei Zählerstand ≥ Vorwahl oder Wischsignal bei Zählerstand ≥ Vorwahl Reset auf Null Betriebsart Sub: Zähler arbeitet subtrahierend Dauersignal bei Zählerstand ≤ Null Wischsignal bei Zählerstand ≤ Null Reset auf Vorwahl Betriebsart Add Ar: Zähler arbeitet addierend Wischsignal bei Zählerstand = Vorwahl automatisches Nullsetzen Betriebsart Sub Ar: Zähler arbeitet subtrahierend Wischsignal bei Zählerstand = Null automatisches Setzen auf Vorwahl Polarität der Eingänge pospol: positive Polarität (PNP) nach +24 V schaltend negpol: negative Polarität (NPN) nach 0V schaltend Eingangsart: E1: INP A = Zähleingang INP B = Zählrichtungseingang Faktor: 0,0001…9,9999 Einstellung mit den Tasten und Faktor 0,0000 wird nicht akzeptiert Achtung! In den Betriebsarten sub, sub Ar (Ausgangssignal bei Zählerstand = Null) muß der Vorwahlwert ganzzahlig durch den Faktor teilbar sein, andernfalls wird der Zähler bei einem Reset auf das nächstgrößere ganzzahlige Vielfache des Faktors gesetzt. Dezimalpunkt (nur anzeigend) 0 = keine Dezimalstelle 0,0 = 1 Dezimalstelle 0,00 = 2 Dezimalstellen 0,000 = 3 Dezimalstellen Dauersignal des Ausgangs, wird bei add. Zählung bei Zählerstand ≥ Vorwahl und bei subtr. Zählung bei Zählerstand ≤ Null aktiv* Dauersignal des Ausgangs, wird bei add. Zählung bei Zählerstand ≥ Vorwahl und bei subtr. Zählung bei Zählerstand ≤ Null passiv** Wischsignal des Ausgangs, wird bei add. Zählung bei Zählerstand = Vorwahl und bei subtr. Zählung bei Zählerstand = Null passiv** Wischsignal des Ausgangs,wird bei add. Zählung bei Zählerstand = Vorwahl und bei subtr. Zählung bei Zählerstand = Null aktiv* Dauer des Wischsignals des Ausgangs, einstellbar von 00,01 s bis 99,99 s * Relaisspule bzw. Optokoppler werden bei Erreichen des Vorwahlwertes angesteuert ** Relaisspule wird bei Erreichen des Vorwahlwertes spannungslos bzw. Optokoppler gesperrt. E2: INP A = Zähleingang add. INP B = Zähleingang subtr. E3: Quadratureingang INP A = Zähleingang 0° INP B = Zähleingang 90° E4: wie E 3, jedoch mit Impulsverdoppelung. Jede Flanke von INP A wird gezählt 26 MN05401009E 6.2.2 Programmierroutine Zeitzähler Betriebsart Sub: Zähler arbeitet subtrahierend Dauersignal bei Zählerstand ≤ Null Wischsignal bei Zählerstand = Null Reset auf Vorwahl Betriebsart Add Ar: Zähler arbeitet addierend Wischsignal bei Zählerstand = Vorwahl automatisches Nullsetzen Betriebsart Sub Ar: Zähler arbeitet subtrahierend Wischsignal bei Zählerstand = Null automatisches Setzen auf Vorwahl Polarität der Eingänge pospol: positive Polarität (PNP), nach +24 V schaltend Dauersignal des Ausgangs,wird bei add. Zählung bei Zählerstand ≥ Vorwahl und bei subtr. Zählung bei Zählerstand ≤ Null aktiv * Dauersignal des Ausgangs,wird bei add. Zählung bei Zählerstand ≥ Vorwahl und bei subtr. Zählung bei Zählerstand ≤ Null passiv** Wischsignal des Ausgangs,wird bei add. Zählung bei Zählerstand = Vorwahl und bei subtr. Zählung bei Zählerstand = Null passiv** Wischsignal des Ausgangs,wird bei add. Zählung bei Zählerstand = Vorwahl und bei subtr. Zählung bei Zählerstand = Null aktiv* Dauer des Wischsignals des Ausgangs,einstellbar von 00,01s bis 99,99 s * Relaisspule bzw. Optokoppler werden bei Erreichen des Vorwahlwertes angesteuert ** Relaisspule wird bei Erreichen des Vorwahlwertes spannungslos bzw. Optokoppler gesperrt. negpol: negative Polarität (NPN), nach 0 V schaltend Zeiteinheit: Zählung in s; 0,1 s; 0,01 s oder 0,001 s* Zählung in min; 0,1 min; 0,01 min* oder 0,001 min Zählung in h; 0,1 h; 0,01 h oder 0,001 h* * je nach Stellung des Dezimalpunktes Zählung in h: min: s Dezimalpunkt (Auflösung) 0 = keine Dezimalstelle 0,0 = 1 Dezimalstelle 0,00 = 2 Dezimalstellen 0,000 = 3 Dezimalstellen MN05401009E 27 deutsch Betriebsart Add: Zähler arbeitet addierend Dauersignal bei Zählerstand ≥ Vorwahl oder Wischsignal bei Zählerstand = Vorwahl Reset auf Null 6.2.3 Programmierroutine Frequenzzähler Torzeit = Zeit, innerhalb der eingehende Impulse gezählt und zur Anzeige gebracht werden. Einstellbereich von 00,01 s bis 99,99 s Einstellung über die Tasten und 00,00 wird als Einstellung nicht akzeptiert Polarität der Eingänge pospol: positive Polarität (PNP), nach +24 V schaltend negpol: negative Polarität (NPN), nach 0 V schaltend Eingangsart: E1: INP A = Zähleingang INP B = Zählrichtungseingang E2: INP A = Zähleingang add. INP B = Zähleingang subtr. E3: Quadratureingang INP A = Zähleingang 0° INP B = Zähleingang 90° E4: wie E 3, jedoch mit Impulsverdoppelung. Jede Flanke von INP A wird gezählt Dauersignal des Ausgangs, wird bei Zählerstand ≥ Vorwahl aktiv * Dauersignal des Ausgangs, wird bei Zählerstand ≥ Vorwahl passiv** Wischsignal des Ausgangs, wird bei Zählerstand = Vorwahl passiv** Wischsignal des Ausgangs, wird bei Zählerstand = Vorwahl aktiv* Dauer des Wischsignals des Ausgangs, einstellbar von 00,01 s bis 99,99 s * Relaisspule bzw. Optokoppler werden bei Erreichen des Vorwahlwertes angesteuert ** Relaisspule wird bei Erreichen des Vorwahlwertes spannungslos bzw. Optokoppler gesperrt. Faktor: 0,0001…9,9999 Einstellung mit den Tasten und Faktor 0,0000 wird nicht akzeptiert Dezimalpunkt (nur anzeigend) 0 = keine Dezimalstelle 0,0 = 1 Dezimalstelle 0,00 = 2 Dezimalstellen 0,000 = 3 Dezimalstellen 28 MN05401009E 7. Vorwahleinstellung: 8. Anschlußbeispiele Wird eine der Pfeiltasten betätigt, ist die Vornullenunterdrückung ca. 4 Sekunden aufgehoben und die rechte Dekade der Vorwahl blinkt im 1-HzRhythmus. Mit der -Taste wird der Wert der blinkenden Dekade in steigender Reihenfolge verändert. Mit der -Taste wird die nächst höhere Dekade angewählt. 4 Sekunden nach der letzten Tastenbetätigung wird automatisch die Vornullenunterdrückung aktiv. In den Betriebsarten Impulszähler und Frequenzzähler wird jetzt der neue Wert übernommen. Ansteuerung über Kontakt programmierte Polarität PNP Einstellung in der 6. Dekade Mit der -Taste das Vorzeichen anwählen; das Vorzeichen erscheint blinkend vor dem aktuellen Zählerstand. Mit der -Taste wird das Vorzeichen dem Vorwahlwert zugeordnet bzw. entfernt. 4 Sekunden nach der letzten Tastenbetätigung wird die Vornullenunterdrückung aktiviert und Vorwahl und Zählerstand mit dem entsprechenden Vorzeichen angezeigt. Achtung: Bei automatischer Wiederholung dürfen keine negativen Vorwahlwerte eingestellt werden! Ansteuerung über Lichtschranke deutsch 7.1 Einstellung des Vorzeichens Ansteuerung über Drehgeber MN05401009E 29 9. Anschlußbelegung 10. Technische Daten Spannungsversorgung: 90…260 VAC, 48 VAC, 24 VAC, 50/60 Hz, ±10%, max. 4 VA oder 11…30 VDC,max. 0,1 A Anzeige: 6stellige, 2zeilige 7-Segment-LCD-Anzeige mit Vorzeichen Istwert 9 mm hoch, Vorwahl 7 mm hoch Symbole für angezeigte Vorwahl und Ausgangskontakt geschlossen Polarität der Eingangssignale: programmierbar; für alle Eingänge gemeinsam Eingangswiderstand: ca. 10 kOhm 9.1 Steckerbelegung X1 Klemme Nr. 1 2 3 4 5 6 7 AC-Version DC-Version nicht belegt nicht belegt Relaisausgang gemeinsamer Kontakt (C) Optokopplerausgang Emitter Relaisausgang Schließer (NO) Relaisausgang Öffner (NC) Optokopplerausgang Kollektor 90…260 VAC/ 11…30 VDC 48 VAC/24 VAC Betriebsspannung 90…260 VAC 0 VDC (GND) 48 VAC/24 VAC Achtung! Bei Einstellung –l– und –l–l– (invertierte Relaisoder Optokoppleransteuerung) ändern sich die Anschlüsse der Klemmen 4 und 5 Klemme AC- und DC-Version Nr. 4 Relaisausgang Öffner (NC) 5 Relaisausgang Schließer (NO) 9.2 Steckerbelegung X2 Klemme Benennung Funktion Funktion Nr. 90…260 VAC 11…30 VDC48 VAC/24 VACVersion Version 1 + 24 VDC Geberversorgungs- nicht belegt spannung 2 GND 0 VDC Bezugsnicht belegt spannung 3 INP A Zähleingang A 4 INP B Zähleingang B 5 RESET Rücksetzeingang 6 GATE Toreingang 7 KEY Tastaturverriegelungseingang Zählfrequenz: über DIL-Schalter für INP A und INP B separat einstellbar 30 Hz 10 kHz (7 kHz bei Eingangsart E3 und E4 Quadratureingang) bei automatischer Wiederholung 900 Hz ohne Zählverluste (500 Hz bei Eingangsart E4) Mindestimpulszeit der Steuereingänge: 5 ms Schaltpegel der Eingänge: Bei AC-Spannungsversorgung Log „0“: 0… 4 VDC Log „1“: 12…30 VDC Bei DC-Spannungsversorgung Ub Log „0“: 0…0,2 x Ub Log „1“: 0,6 x Ub…30 VDC Ub = Netzspannung Impulsform: beliebig, da Schmitt-Trigger-Eingänge Ausgang: Relais mit potentialfreiem Schaltkontakt, Schaltspannung max. 250 VAC/300 VDC Schaltstrom max. 3 A Schaltstrom bei DC min. 30 mA Schaltleistung max. 50 W bei DC max. 2000 VA bei AC oder Optokoppler mit offenem Kollektor und Emitter Schaltleistung: 30 VDC/15 mA Vce sat bei Ic = 15 mA: max. 2,0 V Vce sat bei Ic = 5 mA: max. 0,4 V Ansprechzeit des Ausgangs: Relais: ca. 6 ms Optokoppler: ca. 1 ms Datensicherung: min. 10 Jahre oder 106 Speicherzyklen Geberspannung: 24 VDC –40% / +15 %, 80 mA unstabilisiert bei 24 + 48 VAC-Ausführung 24 VDC –40% / +15 %, 100 mA unstabilisiert bei 90…260 VAC-Ausführung 30 MN05401009E Absicherung: empfohlene externe Sicherung bei DC: 0,125 A, zeitverzögert 90…260 VAC: 0,05 A, zeitverzögert bei 48 VAC: 0,2 A, zeitverzögert bei 24 VAC: 0,4 A, zeitverzögert Störfestigkeit: EN 55011 Klasse B und EN 50082-2 mit geschirmten Dateneingängen Umgebungstemperatur: 0…50°C Lagertemperatur: –25°C…+70°C Gewicht: ca. 240 g (AC-Ausführung mit Relais) Schutzart: IP 65 von vorne Gehäusefarbe: schwarz Reinigung: Die Frontseite des Gerätes darf nur mit einem weichen, mit Wasser angefeuchteten Tuch gereinigt werden. 11. Lieferumfang deutsch – Zähler – Schraubsteckklemme 7polig, Rastermaß 5,08 mm – Schraubsteckklemme 7polig, Rastermaß 3,81 mm – Frontrahmen für Schraubbefestigung Einbauquerschnitt 50 x 50 mm – Frontrahmen für Spannbügelbefestigung Einbauquerschnitt 50 x 50 mm – Spannbügel 12. Bestellschlüssel E5148C142X 1 = 90 ... 260 V AC 2 = 10 ... 30 V DC MN05401009E 31 Maßbilder: max. 10.5 [0.41] 48 [1.89] 45 [1.77] 48 [1.89] 86.5 [3.41] 55 [2.17] max. 9.5 [0.37] 50 [1.97] 45 [1.77] 55 [2.17] 3 [0.12] 15.5 [0.61] Einbauquerschnitt 45 x 45 mm 85.5 [3.37] Mit Frontrahmen abgebildet Nr. 2 Einbauquerschnitt 50 x 50 mm 4 [0.16] 15.5 [0.61] 60 [2.36] 50 [1.97] 63 [2.48] 45 [1.77] 75 [2.95] max. 9.5 [0.37] 85.5 [3.37] 4 [0.16] Mit Frontrahmen abgebildet Nr. 3 Einbauquerschnitt 50 x 50 mm 15.5 [0.61] – Änderungen vorbehalten – Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN CARE (877-386-2273) Eaton.com © 2007 Eaton Corporation All Rights Reserved Printed in USA Publication No. MN05401009E/CPG March 2007
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Eaton E5148C142 Series Operating Instructions Manual

Tipo
Operating Instructions Manual

en otros idiomas