significa dirección.
9
1
2
3
.
ON/OFF
1)
2)
3)
Modo
1)
2)
▼
1)
2)
3)
▲
1)
2)
3)
1)
2)
1)
2)
1)
2) Pressing this key in the other modes, the wind speed switches by "automatic wind speed, high speed,
middle speed, low speed, automatic wind speed " circularly.
“FAN +”
1) When the first power on, the remote controller is set to the automatic wind speed by default. In
dehumidification mode, the fan speed is fixed to low speed and is not adjustable. By pressing the fan
speed key, there is no response to the remote controller.
2) Pressing this key in the other modes, the fan speed switches by "automatic fan speed, low speed, middle
speed, high speed, automatic wind speed " circularly.
Timer
1) Under the shutdown state, press this key to set the opening time, range from 1 hour to 24 hours.
2) Under the running state, press this key to set the shutdown time, range from 1 hour to 24 hours.
3)The timing time is according to the cycle of "1h, 2h, ……, 23h, 24h, cancel, 1h".
4)Exit timing adjustment after 3 seconds without key pressing.
TURBO
1) Extension code remote controller has the effect. The remote controller is no TURBO by default, and the
TURBO key will not work in automatic mode, dehumidification mode and fan mode.
2) Pressing this key in the cooling or heating mode, the TURBO mode switches between opening and
closing. When in the TURBO mode, it does not display the fan speed. Switching mode or entering sleep
function will close TURBO mode.
3) If the air conditioner has four gear fan speeds, the TURBO icon will light up and the fan will run in the
fourth gear wind speed by pressing this key.
ECO
1) The ECO key will not work in automatic mode, dehumidification mode and fan mode.
2) Pressing this key in the cooling or heating mode, the ECO mode switches between opening and closing.
When in the ECO mode, the setting temperature is set to 26℃ (77℉) and other settings are unchanged. If
closing ECO mode, the remote controller will recover to the setting before opening ECO mode. Switching
mode will close ECO mode.
Sleep
1) Pressing this key in the modes except of the fan mode, the sleep function switches between opening and
closing. Switching mode will cancel sleep function.
2) When pressing this key, the fan speed is automatically switched to low wind. However, the wind speed can
be adjusted according to the fan speed key (except of the dehumidification mode).
Light
1) When the first power on, there is no lamplight by default. Pressing this key force to turn off or turn on the
lamplight manually. Decide whether to have this function according to the actual model.
Clock
1) This key is used to set the clock. Pressing enters the hour adjustment state, and the hour digital tube on
the LCD is flickering at the same time. The hour can be set by temperature addition or reduction keys, and
it ranges from 0 to 23.
2) When the hour is set, press this key again to enter the minute adjustment state, and the minute digital tube
on the LCD is flickering at the same time. The minute can be set by temperature addition or reduction
keys, and it ranges from 00 to 59.
3) After adjusting, press the clock key again to confirm the setting and the adjustment state exits. If do not
press the clock key again to confirm, the time adjustment state will exit after 3 seconds, and recover the
clock before the adjustment.
Clean
1) The remote controller is no CLEAN by default.Pressing TURBO key 3S, the CLEAN function
switches between opening and closing.Decide whether to have this function according to the actual
function
Combinatorial key: “CLOCK” + “SLEEP”
1) Pressing the combinatorial key on the remote controller for 3 seconds, the ionizer function switches
between opening and closing.
2) The ionizer function works in any mode. When the ionizer function is ON, if turn off the unit, the ionizer
function will be closed at same time and it is still closed after turning on the unit again.
Combinatorial key: “CLEAN” + “LIGHT”
1) Pressing the combinatorial key on the remote controller for 3 seconds ,the lock function switches between
opening and closing.
2) When it is locked, the remote controller does not work except the lock key.
Combinatorial key: “Mode” “CLEAN” + “LIGHT”
1) Enter address setting
a. On the shutdown interface, press the combinatorial key on the remote controller for 5 seconds to enter the
address setting interface.
b. The last address (when the first power on, 00 is displayed) and the "#" icon are displayed and flickering.
2) The step instructions of setting address
a. At the address setting interface, press the temperature addition or reduction to adjust the setting address,
and it ranges from 00 to 99
b. When the first time entering the interface or pressing the temperature addition or reduction key, the
address display flickers for 3 seconds and then does not flicker.
c. Press the ON / OFF key to enter the sending state and send the address setting code.
3) The step instructions of inquiring address
a. At the address setting interface, press the mode key to send the query code.
b. At this time, the "#" icon flickers. 3 seconds later, it normally displays the last setting addresses and the "#"
icon does not flicker.
4) Exit setting
a. Pressing the combinatorial key key at the same time can exit the address setting interface.
b. If there is no key pressing associated with address setting for more than 30 minutes, the remote controller
will exit the address setting interface.
3. Manual del mando a distancia
El mando a distancia está equipado con 15 botones, y el LCD está recién hecho. Todos los iconos se
mantienen en contacto con el mando a distancia de la pantalla táctil.
Al encenderse por primera vez, la pantalla LCD del mando a distancia muestra primero todos los iconos y
luego entra en el estado de espera, mostrando sólo el reloj de las 12:00 y el icono de la luz.
Sobre el icono de la pantalla LCD:
Pantalla de modo: automático enfriamiento deshumidificación , ventilador y calefacción .
Pantalla de temperatura: muestra la temperatura, que oscila entre 16 ~ 32°C o 61 ~ 90
Pantalla de la velocidad del viento: significa velocidad del viento. significa velocidad del
viento automática.
Pantalla de oscilación: significa viento pendular externo, significa viento pendular interno.
Pantalla del temporizador: significa Temporizador Activado. significa Temporizador Desactivado.
Otra pantalla: significa reloj. significa “Dormir”. significa TURBO, significa ECON. significa
limpieza. significa calefacción eléctrica. significa bloqueo. significa falta de
electricidad.
Función reservada: ans Auto Config. significa ahorro de energía. significa ionizador, significa
viento nuevo. significa inteligencia. significa luz de lámpara.
2. Función de los botones del mando a distancia modelo 2
Al pulsar esta tecla, el mando a distancia se enciende y se apaga de forma circular.
Cuando se enciende por primera vez, el estado de funcionamiento se fija por defecto: la temperatura
establecida 25°C (77°F), modo automático, velocidad automática del ventilador, viento pendular interno y
externo, sin TURBO, sin dormir, sin temporizador, sin bloqueo.
Cuando no es la primera vez que se enciende, se recupera el estado anterior al apagado. Después del
apagado, las funciones de dormir, TURBO, ECO y temporizador serán canceladas.
Al pulsar esta tecla, el mando a distancia cambia por "automático, enfriamiento, deshumidificación, ventilador,
calefacción, automático" de forma circular.
El modo de deshumidificación está bloqueado a 25ÿ y la temperatura no puede ser ajustada. El viento
pendular interno permanece sin cambios según el estado antes de la conmutación, pero el viento pendular
externo es forzado a cerrarse.
Reducción de la temperatura
Ajuste de la temperatura: al pulsar esta tecla, la temperatura establecida se reducirá en 1. La
temperatura del modelo centígrado se reducirá progresivamente en "32°C, 31°C,…17°C, 16°C".
La temperatura del modelo de Fahrenheit se reducirá progresivamente en "90°F, 89°F,… 62°F, 61°F".
Al pulsar esta tecla en el modo de deshumidificación y de ventilador, la temperatura no cambiará.
En el estado de ajuste del reloj (el icono del reloj parpadea), esta tecla se utiliza para ajustar la hora del reloj.
Si sigue presionando, la temperatura cambiará continuamente.
Aumento de temperatura
Ajuste de la temperatura: al pulsar esta tecla, la temperatura establecida se a?adirá en 1. La temperatura
del modelo centígrado se a?adirá progresivamente por "16°C, 17°C,… 31°C, 32°C. La temperatura del
modelo Fahrenheit será a?adido progresivamente por "61°F, 62°F,…, 89°F, 90°F ". Al pulsar esta tecla en
el modo de deshumidificación y el modo de ventilador, la temperatura no cambiará.
En el estado de ajuste del reloj (el icono del reloj parpadea), esta tecla se utiliza para ajustar la hora del reloj.
Si sigue presionando, la temperatura cambiará continuamente.
Oscilación hacia arriba y hacia abajo (Viento pendular externo)
Presionar esta tecla en el modo de deshumidificación no funciona. El viento pendular externo se ve forzado a
cerrarse.
Presionando esta tecla en los otros modos, el péndulo externo cambia por "oscilación, viento fijo, oscilación"
circularmente.
Oscilación a la izquierda y derecha (viento pendular interno)
Presionando esta tecla en el modo de deshumidificación, el viento pendular interno se mantiene sin cambios
según el estado antes de la conmutación.
Presionando esta tecla en los otros modos, el péndulo interno cambia por "oscilación, parada, oscilación"
circularmente.
"VENTILADOR -"
VCuando se enciende por primera vez, el mando a distancia se ajusta a la velocidad automática del ventilador
por defecto. En modo de deshumidificación, la velocidad del ventilador está fijada a baja velocidad y no es
ajustable. Al pulsar la tecla de velocidad del viento, el mando a distancia no responde.