Mitsubishi MSYGL15NA-U1 El manual del propietario

Categoría
Acondicionadores de aire de sistema dividido
Tipo
El manual del propietario
Español
Français
English
OPERATING INSTRUCTIONS
For user
• Tousethisunitcorrectlyandsafely,besuretoreadtheseoperatingin-
structionsbeforeuse.
MANUAL DE INSTRUCCIONES
Paralosclientes
• Parautilizarestaunidaddeformacorrectaysegura,leapreviamente
estasinstruccionesdefuncionamiento.
NOTICE D’UTILISATION
Al’attentiondesclients
• Pour avoir la certitude d’utiliser cet appareil correctement et en toute
sécurité,veuillezlirecettenoticed’instructionsavantdemettreleclima-
tiseursoustension.
SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSY-GL09NA MSY-GL12NA
MSY-GL15NA
01-JG79Y023H01_Cover.indd 1 7/31/2015 5:11:12 PM
En-1
● OPERATING INSTRUCTIONS ●
Since rotating parts and parts which could cause an electric shock are used
in this product, be sure to read these “Safety Precautions” before use.
Since the cautionary items shown here are important for safety, be sure to
observe them.
After reading this manual, keep it together with the installation manual in a
handy place for easy reference.
Be sure to receive a guarantee card from your dealer and check that the
purchased date and shop name, etc. are entered correctly.
Marks and their meanings
WARNING :
Incorrect handling could cause serious hazard, such as
death, serious injury, etc. with a high probability.
CAUTION :
Incorrect handling could cause serious hazard depending
on the conditions.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your fi nger or stick, etc.
:
Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
SAFETY PRECAUTIONS
CONTENTS
SAFETY PRECAUTIONS 1
NAME OF EACH PART 3
PREPARATION BEFORE OPERATION 4
SELECTING OPERATION MODES 5
FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 6
SMART SET OPERATION 6
ECONO COOL OPERATION 7
TIMER OPERATION (ON/OFF TIMER) 7
CLEANING 8
WHEN YOU THINK THAT TROUBLE HAS OCCURRED 9
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 10
INSTALLATION PLACE AND ELECTRICAL WORK 10
SPECIFICATIONS 10
WARNING
Do not connect the power cord to an intermediate point,
use an extension cord, or connect multiple devices to a
single AC outlet.
This may cause overheating, fi re, or electric shock.
Make sure the power plug is free of dirt and insert it se-
curely into the outlet.
A dirty plug may cause fi re or electric shock.
Do not bundle, pull, or modify the power cord, and do not
apply heat or place heavy objects on it.
This may cause fi re or electric shock.
Do not turn the breaker OFF/ON or disconnect/connect the
power plug during operation.
This may create sparks, which can cause fi re.
After the indoor unit is switched OFF with the remote con-
troller, make sure to turn the breaker OFF or disconnect the
power plug.
Do not expose your body directly to cool air for a prolonged
length of time.
This could be detrimental to your health.
The unit should not be installed, relocated, disassembled,
altered, or repaired by the user.
An improperly handled air conditioner may cause re, electric
shock, injury, or water leakage, etc. Consult your dealer.
If the power supply cord is damaged, it must be replaced
by the manufacturer or its service agent in order to avoid a
hazard.
When installing, relocating, or servicing the unit, make
sure that no substance other than the specifi ed refrigerant
(R410A) enters the refrigerant circuit.
Any presence of foreign substance such as air can cause
abnormal pressure rise and may result in explosion or injury.
The use of any refrigerant other than that specifi ed for the
system will cause mechanical failure, system malfunction,
or unit breakdown. In the worst case, this could lead to a
serious impediment to securing product safety.
This appliance is not intended for use by persons (includ-
ing children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concern-
ing use of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they do not
play with the appliance.
Do not insert your fi nger, a stick, or other objects into the
air inlet or outlet.
This may cause injury, since the fan inside rotates at high
speeds during operation.
In case of an abnormal condition (such as a burning smell),
stop the air conditioner and disconnect the power plug or
turn the breaker OFF.
A continued operation in the abnormal state may cause a
malfunction, re, or electric shock. In this case, consult your
dealer.
When the air conditioner does not cool or heat, there is
a possibility of refrigerant leakage. In this case, consult
your dealer. If a repair involves recharging the unit with
refrigerant, ask the service technician for details.
The refrigerant used in the air conditioner is safe. Normally,
it does not leak. However, if refrigerant leaks and comes in
contact with a heat source such as a fan heater, kerosene
heater, or cooking stove, it will create a harmful gas.
The user should never attempt to wash the inside of the
indoor unit. Should the inside of the unit require cleaning,
contact your dealer.
Unsuitable detergent may cause damage to plastic material
inside the unit, which may result in water leakage. Should
detergent come in contact with electrical parts or the motor,
it will result in a malfunction, smoke, or fi re.
02-JG79Y023H01_en.indd 1 7/31/2015 5:11:42 PM
En-2
SAFETY PRECAUTIONS
CAUTION
Do not touch the air inlet or the aluminum ns of the in-
door/outdoor unit.
This may cause injury.
Do not use insecticides or fl ammable sprays on the unit.
This may cause a fi re or deformation of the unit.
Do not expose pets or houseplants to direct airfl ow.
This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under the
indoor/outdoor unit.
Water may drip down from the unit, which may cause damage
or malfunction.
Do not leave the unit on a damaged installation stand.
The unit may fall and cause injury.
Do not step on an unstable bench to operate or clean the
unit.
This may cause injury if you fall down.
Do not pull the power cord.
This may cause a portion of the core wire to break, which may
cause overheating or fi re.
Do not charge or disassemble the batteries, and do not
throw them into a fi re.
This may cause the batteries to leak, or cause a fi re or explo-
sion.
Do not operate the unit for more than 4 hours at high hu-
midity (80% RH or more) and/or with windows or outside
door left open.
This may cause the water condensation in the air conditioner,
which may drip down, wetting or damaging the furniture.
The water condensation in the air conditioner may contribute
to growth of fungi, such as mold.
Do not use the unit for special purposes, such as storing
food, raising animals, growing plants, or preserving preci-
sion devices or art objects.
This may cause deterioration of quality, or harm to animals
and plants.
Do not expose combustion appliances to direct airfl ow.
This may cause incomplete combustion.
Never put batteries in your mouth for any reason to avoid
accidental ingestion.
Battery ingestion may cause choking and/or poisoning.
Before cleaning the unit, switch it OFF and disconnect the
power plug or turn the breaker OFF.
This may cause injury, since the fan inside rotates at high
speeds during operation.
When the unit will be unused for a long time, disconnect the
power plug or turn the breaker OFF.
The unit may accumulate dirt, which may cause overheating
or fi re.
Replace all batteries of the remote controller with new ones
of the same type.
Using an old battery together with a new one may cause
overheating, leakage, or explosion.
If the battery uid comes in contact with your skin or clothes,
wash them thoroughly with clean water.
If the battery uid comes in contact with your eyes, wash them
thoroughly with clean water and immediately seek medical
attention.
Ensure that the area is well-ventilated when the unit is oper-
ated together with a combustion appliance.
Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a
possibility of a lightning strike.
The unit may be damaged if lightning strikes.
After the air conditioner is used for several seasons, per-
form inspection and maintenance in addition to normal
cleaning.
Dirt or dust in the unit may create an unpleasant odor, con-
tribute to growth of fungi, such as mold, or clog the drain pas-
sage, and cause water to leak from the indoor unit. Consult
your dealer for inspection and maintenance, which require
specialized knowledge and skills.
Do not operate switches with wet hands.
This may cause electric shock.
Do not clean the air conditioner with water or place an object
that contains water, such as a fl ower vase, on it.
This may cause fi re or electric shock.
Do not step on or place any object on the outdoor unit.
This may cause injury if you or the object falls down.
For installation
WARNING
Consult your dealer for installing the air conditioner.
It should not be installed by the user since installation requires
specialized knowledge and skills. An improperly installed air
conditioner may cause water leakage, fi re, or electric shock.
Provide a dedicated power supply for the air conditioner.
A non-dedicated power supply may cause overheating or re.
Do not install the unit where fl ammable gas could leak.
If gas leaks and accumulates around the unit, it may cause an
explosion.
Ground the unit correctly.
Do not connect the ground wire to a gas pipe, water pipe,
lightning rod, or a telephone ground wire. Improper grounding
may cause electric shock.
CAUTION
Install a Ground Fault Interrupt (GFI) circuit breaker depend-
ing on the installation location of the air conditioner (such
as highly humid areas).
If the Ground Fault Interrupt (GFI) breaker is not installed, it
may cause electric shock.
Ensure that the drain water is properly drained.
If the drain passage is improper, water may drip down from
the indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
IMPORTANT
Dirty lters cause condensation in the air conditioner which will con-
tribute to the growth of fungi such as mold. It is therefore recommended
to clean air fi lters every 2 weeks.
02-JG79Y023H01_en.indd 2 7/31/2015 5:11:42 PM
En-3
● OPERATING INSTRUCTIONS ●
Operation indicator lamp
Remote control receiving section
Emergency
operation switch
Page 5
Air inlet (back and side)
Refrigerant piping
Drainage hose
Air outlet
Drain outlet
Horizontal vane
Air outlet
Air fi lter
(Nano platinum fi lter)
Air inlet
Heat exchanger
Front panel
Outdoor unit
NAME OF EACH PART
Indoor unit Remote controller
Outdoor units may be different in appearance.
Air cleaning fi lter
(Anti-Allergy Enzyme
Filter)
Remote controller
holder
Signal transmitting
section
Distance of signal :
About 20 ft. (6 m)
Beep(s) is (are) heard
from the indoor unit when
the signal is received.
Operation display
section
OFF/ON
(stop/operate)
button
Temperature buttons
Pages 4, 5
Operation
select button
Page 5
ECONO
COOL
button
Page 7
FAN speed
control button
Page 6
Battery
replacement
indicator
Page 4
Off-timer button Page 7
On-timer button Page 7
VANE
control button
Page 6
TIME set buttons Pages 4, 7
Increase time
Decrease time
CLOCK button Page 4
RESET button Page 4
Lid
Slide down to open
• Install the remote control-
ler holder in a place where
the signal can be received
by the indoor unit.
Only use the remote controller provided with the unit.
Do not use other remote controllers.
If two or more indoor units are installed in proximity to one another, an indoor
unit that is not intended to be operated may respond to the remote controller.
SMART SET button Page 6
Display section
02-JG79Y023H01_en.indd 3 7/31/2015 5:11:43 PM
En-4
• Make sure the polarity of the batteries is correct.
Do not use manganese batteries and leaking batteries. The remote controller
could malfunction.
• Do not use rechargeable batteries.
• The battery replacement indicator lights up when the battery is running low.
In about 7 days after the indicator starts lights up, the remote controller stops
working.
• Replace all batteries with new ones of the same type.
Batteries can be used for approximately 1 year. However, batteries with
expired shelf lives last shorter.
Press RESET gently using a thin instrument.
If the RESET button is not pressed, the remote controller may not operate
correctly.
Before operation: Insert the power supply plug into the power outlet and/or
turn the breaker on.
Installing the remote controller batteries
PREPARATION BEFORE OPERATION
Press CLOCK gently using a thin instrument.
Setting current time
Changing temperature units (°F→°C)
Unit is preset with °F.
1.
Press RESET while
the temperature but-
tons are pressed.
Press RESET gently using a thin instrument.
To change temperature unit from °C to °F, press RESET.
1.
Remove the front lid.
3.
Install the front lid.
4.
Press RESET.
1.
Press CLOCK.
3.
Press CLOCK again.
2.
Press the TIME buttons to set
the time.
Each press increases/de-
creases the time by 1 minute
(10 minutes when pressed
longer).
2.
Insert the negative
pole of AAA
alkaline batteries fi rst.
02-JG79Y023H01_en.indd 4 7/31/2015 5:11:43 PM
En-5
● OPERATING INSTRUCTIONS ●
Operation indicator lamp
Emergency operation
When the remote controller cannot be used...
Emergency operation can be activated by pressing the emergency operation
switch (E.O.SW) on the indoor unit.
Each time the E.O.SW is pressed, the operation changes in
the following order:
1
Press
to start the operation.
2
Press to select operation mode. Each press
changes mode in the following order:
3
Press or to set the temperature.
Each press raises or lowers the temperature by 1°F
(1°C).
Press to stop the operation.
The same setting is selected the next time by simply pressing
.
Auto restart function
If a power failure occurs or the main power is turned off during operation, “Auto
restart function” automatically starts operation in the same mode as the one
set with the remote controller just before the shutoff of the main power. When
timer is set, timer setting is cancelled and the unit starts operation when power
is resumed.
If you do not want to use this function, please consult the service repre-
sentative because the setting of the unit needs to be changed.
SELECTING OPERATION MODES
Set temperature : 75°F (24°C)
Fan speed : Medium
Horizontal vane : Auto
(I FEEL ) (COOL) (DRY) (FAN)
Emergency COOL
Stop
Note:
The rst 30 minutes of operation is test run. Temperature
control does not work, and fan speed is set to High.
Operation indicator lamp
The operation indicator lamp shows the operation state of the unit.
Indication Operation state Room temperature
The unit is operating to reach the set
temperature
About 4°F (2°C) or
more away from set
temperature
The room temperature is approach-
ing the set temperature
About 2 to 4°F (1 to
2°C) from set tem-
perature
Lighted Not lighted
I FEEL mode
The unit selects the operation mode according to the room tem-
perature when I FEEL is selected. When the room temperature is
higher than 77°F (25°C), COOL is selected (set temperature: 75°F
[24°C]). When the room temperature is lower than 77°F (25°C),
DRY is selected. However, when operation is stopped and then
started within 2 hours, the mode which has been selected previously
is operated.
Note:
During COOL operation, the set temperature may not be changed when
the room temperature is more than 4°F (2°C) higher than the set tempera-
ture. In this case, please wait until the room temperature drops to within
4°F (2°C) of the set temperature.
COOL mode
Enjoy cool air at your desired temperature.
Note:
Do not operate COOL mode at very low outside temperatures (less than
14°F [-10°C]). Water condensed in the unit may drip and wet or damage
furniture, etc.
DRY mode
Dehumidify your room. The room may be cooled slightly.
Temperature cannot be set during DRY mode.
FAN mode
Circulate the air in your room.
02-JG79Y023H01_en.indd 5 7/31/2015 5:11:44 PM
En-6
FAN SPEED AND
AIRFLOW DIRECTION ADJUSTMENT
SMART SET OPERATION
Press to select fan speed. Each press changes
fan speed in the following order:
(AUTO) (Quiet) (Low) (Med.) (High) (Super High)
• Two short beeps are heard from the indoor unit when set to AUTO.
Use higher fan speed to cool the room quicker. It is recommended to
lower the fan speed once the room is cool.
• Use lower fan speed for quiet operation.
Press to select airfl ow direction. Each press
changes airfl ow direction in the following order:
(AUTO) (1) (2) (3) (4) (5) (SWING)
Two short beeps are heard from the indoor unit when set to AUTO.
Airflow direction
(AUTO) .........The vane is set to the most effi cient airfl ow direction. :horizontal
position.
(Manual) .......For efficient air conditioning, select the upper position for
COOL/DRY, and the lower position for FAN. If the position (4)
or (5) is selected during COOL/DRY, the vane automatically
moves to the upward position after 0.5 to 1 hour to prevent
any condensation from dripping.
(Swing) .........The vane moves up and down intermittently.
To change the horizontal airfl ow direction.
Move the vertical vane manually before starting operation.
1
Press during COOL or ECONO COOL mode to
select SMART SET mode.
2
Set the temperature, fan speed, and airfl ow direction.
The same setting is selected from the next time by simply pressing
.
One setting can be saved.
Select the appropriate temperature, fan speed, and airflow direction
according to your room.
Press again to cancel SMART SET operation.
SMART SET operation also is cancelled when the MODE button is
pressed.
SMART SET operation
A simplified set back function enables to recall the preferred (preset) setting with
a single push of the
button. Press the button again and you can go back to
the previous setting in an instance.
Example of use:
1. Low energy mode
Set the temperature 4°F (2°C) to 6°F (3°C) warmer in COOL mode. This set-
ting is suitable for unoccupied room, and while you are sleeping.
2. Saving frequently used settings
Save your preferred setting for COOL/ECONO COOL. This enables you to
select your preferred setting with a single push of the button.
02-JG79Y023H01_en.indd 6 7/31/2015 5:11:45 PM
En-7
● OPERATING INSTRUCTIONS ●
ECONO COOL OPERATION
Press during COOL mode page 5 to start
ECONO COOL operation.
The unit performs swing operation vertically in various cycles according to the
temperature of airflow. Set temperature is set 4°F (2°C) higher automatically.
Press again to cancel ECONO COOL operation.
ECONO COOL operation is also cancelled when the VANE button is
pressed.
What is “ECONO COOL”?
Swing airfl ow (change of airfl ow) makes you feel cooler than stationary airfl ow.
So, even though the set temperature is automatically set at 4°F (2°C) higher, it is
possible to perform cooling operation with keeping comfort. As a result, energy can
be saved.
1
Press or during operation to set the timer.
(ON timer) : The unit turns ON at the set time.
(OFF timer) : The unit turns OFF at the set time.
* or blinks.
* Make sure that the current time is set correctly. Page 4
2
Press (Increase) and (Decrease) to set the
time of timer.
Each press increases or decreases the set time by 10 minutes.
Set the timer while
or is blinking.
3
Press or again to cancel timer.
Note:
ON and OFF timers can be set together. mark indicates the order of timer
operations.
If power failure occurs while ON/OFF timer is set, see page 5 “Auto restart
function”.
TIMER OPERATION (ON/OFF TIMER)
02-JG79Y023H01_en.indd 7 7/31/2015 5:11:46 PM
En-8
Instructions:
CLEANING
Switch off the power supply or turn off the breaker before cleaning.
Be careful not to touch the metal parts with your hands.
Do not use benzine, thinner, polishing powder, or insecticide.
Use only diluted mild detergents.
Do not expose parts to direct sunlight, heat, or fi re to dry.
Do not use water hotter than 120°F (50°C).
Front panel
1. Lift the front panel until a “click” is heard.
2. Hold the hinges and pull to remove as shown in the illustration above.
Wipe with a soft dry cloth or rinse it with water.
Do not soak it in water for more than two hours.
Dry it well in shade.
3. Install the front panel by following the removal pro-
cedure in reverse. Close the front panel securely
and press the positions indicated by the arrows.
Hole
Hinge
Air cleaning fi lter
(Anti-Allergy Enzyme Filter)
Back side of air fi lter
Every 3 months:
Remove dirt by a vacuum cleaner.
When dirt cannot be removed by vacuum cleaning:
Soak the fi lter and its frame in lukewarm water before rinsing it.
After washing, dry it well in shade.
Every year:
Replace it with a new air cleaning fi lter for best performance.
Parts Number MAC-408FT-E
Pull to remove from the air fi lter
Important
Clean the lters regularly for best performance and to
reduce power consumption.
Dirty fi lters cause condensation in the air conditioner
which will contribute to the growth of fungi such as
mold. It is therefore recommended to clean air lters
every 2 weeks.
Air fi lter (Nano platinum fi lter)
Clean every 2 weeks
Remove dirt by a vacuum cleaner, or rinse with water.
After washing with water, dry it well in shade.
What is “Nano platinum fi lter”?
Nano platinum is a ceramic particle that includes a platinum nanoparticle.
The particles are incorporated into the lter material, which results in pro-
viding semi-permanent antibacterial and deodorizing characteristics for the
lter. Nano platinum surpasses the catechin (a biofl avonoid that is found
in green tea) in performance. Nano platinum lter uses this compound not
only to improve air quality but also to eliminate bacteria and viruses. This air
lter has a semi-permanent lasting effect even after washing it with water.
02-JG79Y023H01_en.indd 8 7/31/2015 5:11:46 PM
En-9
● OPERATING INSTRUCTIONS ●
Even if these items are checked, when the unit does not recover from the
trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
The unit cannot be operated.
Is the breaker turned on?
Is the power supply plug connected?
Is the ON timer set? Page 7
The horizontal vane does not
move.
Are the horizontal vanes installed correctly?
Is the fan guard deformed?
The unit cannot be operated
for about 3 minutes when
restarted.
This protects the unit according to instruc-
tions from the microprocessor. Please wait.
Mist is discharged from the air
outlet of the indoor unit.
The cool air from the unit rapidly cools mois-
ture in the air inside the room, and it turns
into mist.
The swing operation of the
HORIZONTAL VANE is
suspended for a while, then
restarted.
This is for the swing operation of the HORI-
ZONTAL VANE to be performed normally.
The airfl ow direction changes
during operation.
The direction of the horizontal
vane cannot be adjusted with
the remote controller.
When the unit is operated in COOL or DRY
mode, if the operation continues with air
blowing down for 0.5 to 1 hour, the direction
of the air ow is automatically set to upward
position to prevent water from condensing
and dripping.
The unit starts operation by
itself when the main power is
turned on, but hasn’t received
sign from the remote control-
ler.
These models are equipped with an auto re-
start function. When the main power is turned
off without stopping the unit with the remote
controller and is turned on again, the unit
starts operation automatically in the same
mode as the one set with the remote control-
ler just before the shutoff of the main power.
Refer to “Auto restart function” page 5 .
The indoor unit discolors over
time.
Although plastic turns yellow due to the infl u-
ence of some factors such as ultraviolet light
and temperature, this has no effect on the
product functions.
Outdoor Unit
The fan of the outdoor unit
does not rotate even though
the compressor is running.
Even if the fan starts to rotate,
it stops soon.
When the outside temperature is low during
cooling operation, the fan operates intermit-
tently to maintain suffi cient cooling capacity.
Water leaks from the outdoor
unit.
During COOL and DRY operations, pipe or
pipe connecting sections are cooled and this
causes water to condense.
Remote controller
The display on the remote
controller does not appear or
it is dim. The indoor unit does
not respond to the remote
control signal.
Are the batteries exhausted? Page 4
Is the polarity (+, -) of the batteries correct?
Page 4
Are any buttons on the remote controller of
other electric appliances being pressed?
Symptom Explanation & Check points
Does not cool
The room cannot be cooled
suffi ciently.
Is the temperature setting appropriate?
Page 5
Is the fan setting appropriate? Please
change
fan speed to High or Super High.
Page 6
Are the fi lters clean? Page 8
Is the fan or heat exchanger of the indoor unit
clean?
Are there any obstacles blocking the air inlet
or outlet of the indoor or outdoor unit?
Is a window or door open?
When a ventilation fan or a gas cooker is
used in a room, the cooling load increases,
resulting in an insuffi cient cooling effect.
When the outside temperature is high, the
cooling effect may not be suffi cient.
It may take a certain time to reach the setting
temperature or may not reach that depending
on the size of the room, the ambient tempera-
ture, and the like.
Airfl ow
The air from the indoor unit
smells strange.
Are the fi lters clean? Page 8
Is the fan or heat exchanger of the indoor unit
clean?
The unit may suck in an odor adhering to the
wall, carpet, furniture, cloth, etc. and blow it
out with the air.
Sound
Cracking sound is heard. This sound is generated by the expansion/
contraction of the front panel, etc. due to
change in temperature.
“Burbling” sound is heard. This sound is heard when the outside air is
absorbed from the drain hose by turning on
the range hood or the ventilation fan, making
water fl owing in the drain hose to spout out.
This sound is also heard when the outside air
blows into the drain hose in case the outside
wind is strong.
Mechanical sound is heard
from the indoor unit.
This is the switching sound in turning on/off
the fan or the compressor.
The sound of water fl owing
is heard.
This is the sound of refrigerant or condensed
water fl owing in the unit.
Hissing sound is sometimes
heard.
This is the sound when the ow of refrigerant
inside the unit is changed.
In the following cases, stop using the air conditioner and consult your
dealer.
When water leaks or drips from the indoor unit.
When the upper operation indicator lamp blinks.
When the breaker trips frequently.
The remote control signal is not received in a room where an electronic ON/OFF
type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
Operation of the air conditioner interferes with radio or TV reception. An ampli-
er may be required for the affected device.
When an abnormal sound is heard.
When any refrigerant leakage is found.
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
02-JG79Y023H01_en.indd 9 7/31/2015 5:11:46 PM
En-10
Installation place
Avoid installing the air conditioner in the following places.
Where there is much machine oil.
Salty places such as the seaside.
Where sulfi de gas is generated such as hot spring, sewage, waste water.
Where oil is splashed or where the area is lled with oily smoke (such as cook-
ing areas and factories, in which the properties of plastic could be changed
and damaged).
Where there is high-frequency or wireless equipment.
Where the air from the outdoor unit air outlet is blocked.
Where the operation sound or air from the outdoor unit bothers the house next
door.
The mounting height of indoor unit 5.9 ft. to 7.5 ft. (1.8 m to 2.3 m) is recom-
mended. If it is impossible, please consult your dealer.
Electrical work
Provide an exclusive circuit for the power supply of the air conditioner.
Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
INSTALLATION PLACE AND
ELECTRICAL WORK
SPECIFICATIONS
To prevent the effects
of a fl uorescent lamp,
keep as far apart as
possible.
wall, etc.
Inverter-type
uorescent lamp
Keep a space to
prevent the pic-
ture distortion or
the noise.
3 ft. (1 m)
or more
Radio
4 in. (100 mm)
or more
For the optimum effi ciency
and to extend the life time
of using, the outdoor unit
should be installed in a
well-ventilated dry place.
TV
Cordless
phone or
Portable
phone
10 ft.
(3 m) or
more
3 ft. (1 m)
or more
The installation location of the outdoor unit should be
at least 10 ft. (3 m) away from the antennas for TV
sets, radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours. Page 5
This dries the inside of the unit.
Moisture in the air conditioner contributes to favorable conditions for
growth of fungi, such as mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter. Page 8
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the ground wire is connected correctly.
Refer to the “PREPARATION BEFORE OPERATION”,
and follow the instructions. Page 4
WHEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
8 in. (200 mm)
or more)
Guaranteed operating range
Indoor Outdoor
Cooling
Upper limit
90°F (32.2°C) DB 115°F (46.1°C) DB
73°F (22.8°C) WB
Lower limit
67°F (19.4°C) DB 14°F (-10°C) DB
57°F (13.9°C) WB
DB : Dry Bulb
WB : Wet Bulb
4
Note:
1. The guaranteed operating range value is for 1:1 System Application.
2. If the outdoor temperature is below the lower limit of guaranteed operating
range, the outdoor unit may stop operation until the outdoor temperature
exceeds the lower limit.
02-JG79Y023H01_en.indd 10 7/31/2015 5:11:47 PM
Sp-1
● MANUAL DE INSTRUCCIONES ●
Puesto que este producto tiene piezas rotatorias y piezas que pueden pro-
vocar descargas eléctricas, lea atentamente las “Medidas de seguridad”
antes de usarlo.
Tome las precauciones aconsejadas en este manual, ya que son impor-
tantes para una utilización segura del producto.
Después de leer este manual, guárdelo a mano junto con el manual de
instalación para poder recurrir a él con facilidad.
Asegúrese de recibir la garantía de su distribuidor y comprobar que contie-
ne la fecha de compra, el nombre del establecimiento, etc. correctos.
Indicaciones y sus signifi cados
ATENCIÓN:
Una manipulación incorrecta podría conllevar con toda
probabilidad un peligro grave, por ejemplo, de muerte o
de heridas graves.
CUIDADO:
Una manipulación incorrecta podría conllevar, según las
condiciones, un peligro grave.
Símbolos utilizados en este manual y su signifi cado
: Asegúrese de no hacerlo.
: Siga las instrucciones estrictamente.
: No introduzca nunca los dedos ni objetos, etc.
: No se suba a la unidad interior/exterior ni ponga nada encima.
: Peligro de descarga eléctrica. Tenga cuidado.
: Asegúrese de desconectar el enchufe de alimentación de la toma
de corriente.
: Asegúrese de desconectar la corriente.
MEDIDAS DE SEGURIDAD
ÍNDICE
ATENCIÓN
No conecte el cable de alimentación a un punto intermedio;
utilice una alargadera o conecte varios dispositivos a una
sola toma de CA.
Podría causar sobrecalentamiento, fuego o descarga eléctrica.
Asegúrese que el enchufe no tiene polvo e insértelo de
forma segura en la toma de corriente.
Si el enchufe está sucio puede provocar fuego o una des-
carga eléctrica.
No enrolle ni cambie ni tire del cable de alimentación, y no
aplique calor ni coloque objetos pesados sobre el mismo.
Podría causar fuego o una descarga eléctrica.
No accione el disyuntor OFF/ON ni desconecte/conecte el
enchufe de alimentación durante el funcionamiento.
Podría generar chispas y originar un fuego.
Una vez que la se apaga la unidad interior con el controlador
remoto, asegúrese de que coloca el disyuntor en OFF o que
desconecta el enchufe de alimentación.
Evite la exposición directa de la piel al aire frío durante un
periodo de tiempo prolongado.
Puede ser perjudicial para la salud.
El usuario no debe instalar, cambiar de sitio, desmontar,
alterar ni reparar la unidad.
Si no se maneja correctamente, el acondicionador de aire
puede causar fuego, descarga eléctrica, lesiones, escape
de agua, etc. Consulte con su distribuidor.
Si el cable de alimentación está dañado, deberá ser susti-
tuido por el fabricante o su agente de mantenimiento para
evitar cualquier riesgo.
Al instalar, reubicar o reparar la unidad, asegúrese de que
en el circuito de refrigeración no entra ninguna otra sustan-
cia que no sea el refrigerante especifi cado (R410A).
La presencia de cualquier otra sustancia extraña, como aire
por ejemplo, puede provocar una elevación anómala de la
presión, una explosión o daños corporales.
El uso de un refrigerante distinto al especifi cado por el sis-
tema ocasionará fallos mecánicos, malfuncionamiento del
sistema o averías en la unidad. En el peor de los casos, esto
podría llegar a ser un serio impedimento para garantizar el
uso seguro del producto.
Este aparato no debe ser utilizado por personas (incluidos
niños) que presenten una discapacidad física, sensorial o
mental así como aquellos que dispongan de la experiencia
o el conocimiento, a menos que lo hagan bajo la super-
visión o instrucción relativa al uso del aparato por una
persona responsable de su seguridad.
Se debe supervisar a los niños para garantizar que no
jueguen con el aparato.
No introduzca los dedos, palos, etc. en las entradas/sa-
lidas de aire.
Podría causar daños, puesto que el ventilador del interior
gira a alta velocidad durante el funcionamiento.
En caso de que se produzca una condición anómala (como
olor a quemado), pare el aparato y desconecte el enchufe
de alimentación o coloque el disyuntor en OFF.
Si se prolonga el funcionamiento en la condición anómala
puede producirse un fallo, fuego o una descarga eléctrica.
En tal caso, consulte a su distribuidor.
Cuando el acondicionador de aire no enfría o no calienta,
es posible que haya una fuga del refrigerante. En tal caso,
consulte a su distribuidor. Si una reparación exige la recar-
ga de la unidad con refrigerante, solicite más información
al técnico de servicio.
El refrigerante que se usa en el acondicionador de aire es
seguro. Normalmente no tiene fugas. Ahora bien, si hay fuga
de refrigerante y éste entra en contacto con una fuente de
calor como un calentador de ventilador, un calentador de
parafi na o un horno de cocina, generará gases perjudicia-
les.
El usuario nunca debería intentar lavar el interior de la
unidad interior. Si el interior de la unidad requiere limpieza,
póngase en contacto con el distribuidor.
Un detergente inadecuado puede provocar daños a los ma-
teriales plásticos del interior de la unidad, lo que puede tener
como consecuencia pérdidas de agua. Si el detergente entra
en contacto con las partes eléctricas del motor, provocará
mal funcionamiento, humo o fuego.
MEDIDAS DE SEGURIDAD 1
NOMBRE DE LAS PARTES 3
PREPARACIÓN ANTES DE LA PUESTA EN MARCHA 4
SELECCIÓN DE MODOS DE FUNCIONAMIENTO 5
VELOCIDAD DEL VENTILADOR Y AJUSTE DE LA DIRECCIÓN DEL AIRE 6
FUNCIONAMIENTO SMART SET (SELECCIÓN INTELIGENTE) 6
FUNCIONAMIENTO DE LA DESCONEXIÓN AUTOMÁTICA (ECONO COOL) 7
FUNCIONAMIENTO DEL TEMPORIZADOR (ACTIVACIÓN/DESACTIVACIÓN DEL TEMPORIZADOR) 7
LIMPIEZA 8
SI CREE QUE HA OCURRIDO ALGÚN PROBLEMA 9
CUANDO EL ACONDICIONADOR DE AIRE NO SE VAYA A UTILIZAR DURANTE MUCHO TIEMPO 10
LUGAR DE INSTALACIÓN Y TRABAJO ELÉCTRICO 10
ESPECIFICACIONES 10
Sp-2
MEDIDAS DE SEGURIDAD
CUIDADO
No toque la entrada de aire ni la aleta de aluminio de la
unidad interior/exterior.
Podría hacerse daño.
No eche insecticidas ni pulverizadores infl amables sobre
la unidad.
Podrían provocar incendios o deformaciones de la unidad.
Evite la exposición directa de animales domésticos o plantas
al fl ujo de aire.
Puede causar daños a los animales y las plantas.
No coloque otros electrodomésticos o muebles debajo de
la unidad interior/exterior.
Podría gotear agua desde la unidad, que podría causar daños
o hacer que funcionara mal.
No instale la unidad en un soporte roto.
La unidad podría caer y causar daños.
Mientras limpia o hace funcionar la unidad, no tenga los pies
en una superfi cie inestable.
Si se cayera, podría hacerse daño.
No tire del cable de alimentación.
Podría hacer que se rompa parte del núcleo del cable, lo que
puede causar sobrecalentamiento o fuego.
No cargue ni desarme las pilas y no las arroje al fuego.
Podría provocar fugas en las pilas, o causar fuego o una
explosión.
La unidad no debe estar en funcionamiento más de 4 horas
en condiciones de humedad elevada (80% de humedad
relativa o superior) y/o con la puerta de entrada o las ven-
tanas abiertas.
Esto podría causar un descenso en la condensación de agua
en el acondicionador de aire que podría humedecer o dañar
el mobiliario.
La condensación de agua en el acondicionador de aire podría
contribuir a la formación de hongos, como el moho.
No use la unidad para nes especiales, como para alma-
cenar alimentos, criar animales, cultivar plantas o guardar
dispositivos de precisión u objetos de arte.
Podría deteriorar la calidad o causar daños a los animales y
plantas.
Evite la exposición directa de aparatos de combustión al
ujo de aire.
Podría interrumpir la combustión.
Para evitar una ingestión accidental, no coloque las pilas en
su boca bajo ningún concepto.
La ingestión de las pilas puede causar asfi xia y/o envenena-
miento.
Antes de limpiar la unidad, apáguela y desconecte el cable
de alimentación o coloque el disyuntor en OFF.
Podría causar daños, puesto que el ventilador del interior gira
a alta velocidad durante el funcionamiento.
Si la unidad va a dejar de usarse un tiempo prolongado,
desconecte el cable de alimentación o coloque el disyuntor
en OFF.
La unidad puede acumular polvo y provocar sobrecalenta-
miento o fuego.
Sustituya las pilas del controlador remoto por otras nuevas
de la misma clase.
La utilización de una pila usada junto con una nueva puede
causar sobrecalentamiento, provocar una fuga o producir una
explosión.
Si el líquido de la pila entra en contacto con la piel o la ropa,
lávelas a fondo con agua limpia.
Si el líquido de la pila entra en contacto con los ojos, lávelos
a fondo con agua limpia y acuda a un médico de inmediato.
Asegúrese de que la zona está bien ventilada cuando la
unidad esté en funcionamiento junto con un aparato de
combustión.
Una ventilación inadecuada puede originar falta de oxígeno.
Coloque el disyuntor en OFF si oye truenos y hay posibilidad
de que caigan rayos.
La unidad puede resultar dañada si cae algún rayo.
Tras varias estaciones con el acondicionador de aire en
funcionamiento, efectúe una inspección y el mantenimiento
además de la limpieza habitual.
Si hay polvo o suciedad en la unidad se puede producir un olor
desagradable, contribuir al crecimiento de hongos, como el
moho, o bien bloquear el conducto de drenaje, lo que hace que
gotee agua de la unidad interior. Consulte con su distribuidor
sobre la inspección y el mantenimiento, puesto que exigen
conocimientos y capacidades especializadas.
ATENCIÓN
Pida a su distribuidor que instale el aire acondicionado.
No debe instalarlo el usuario, puesto que requiere conocimien-
tos y capacidades especializadas. Si no se instala correcta-
mente, puede provocar fugas, fuego o descargas eléctricas.
Dedique una toma de alimentación en exclusiva al acondi-
cionador de aire.
Si no se utiliza una toma de alimentación en exclusiva, pueden
producirse sobrecalentamiento o fuego.
No instale la unidad donde pueda haber fugas de gas
infl amable.
Si hay una fuga de gas y éste se acumula cerca de la unidad,
podría producirse una explosión.
Conecte la unidad a una toma a tierra.
No conecte el cable de tierra a una tubería de gas, tubería
de agua, pararrayos o cable de tierra de un teléfono. Si no,
podría producirse una descarga eléctrica.
CUIDADO
Instale un disyuntor de pérdidas de tierra en función del
lugar de instalación del aire acondicionado (por ejemplo,
áreas muy húmedas).
Si no instala el disyuntor de pérdidas de tierra, podrían pro-
ducirse descargas eléctricas.
Asegúrese de que se drena correctamente el agua de
drenaje.
Si el conducto de drenaje no es correcto, el agua podría caer
desde la unidad interior/exterior, causando humedad y daños
en el mobiliario.
Si se produce una condición anómala
Pare de inmediato el acondicionador de aire y consulte a su distribuidor.
No utilice los mandos con las manos mojadas.
Podría producirse una descarga eléctrica.
No limpie el acondicionador de aire con agua ni coloque
sobre él un objeto que contenga agua, como un fl orero.
Podría causar fuego o una descarga eléctrica.
No se suba a la unidad exterior ni coloque ningún objeto
encima.
Si se cayera usted o el objeto, podría haber daños.
Para la instalación
IMPORTANTE
Los ltros sucios pueden provocar condensación en el acondiciona-
dor de aire que contribuye a la formación de hongos, como el moho.
Por lo tanto, es recomendable limpiar los fi ltros cada 2 semanas.
Sp-3
● MANUAL DE INSTRUCCIONES ●
Entrada de aire
(lado posterior y lateral)
Tubería de refrigerante
Manguera de drenaje
Salida de aire
Salida de drenaje
Soporte del controla-
dor remoto
Sección de transmi-
sión de señales
Distancia de la señal:
Aprox. 20 pies (6 m)
Cuando se recibe la
señal, la unidad interior
emite un sonido.
Sección de pantalla
de accionamiento
Botones de tempera-
tura
Páginas
4, 5
Botón de selección
del modo de funcio-
namiento
Página 5
Botón de control
de velocidad del
ventilador Página 6
Botón de desactivación del
temporizador
Página 7
Botón de activación del
temporizador Página 7
Botón de
control de las
lamas
Página 6
Botones de ajuste del TIMER
(TEMPORIZADOR)
Páginas
4, 7
Aumentar tiempo
Reducir tiempo
Botón de ajuste del
reloj (CLOCK) Página 4
Botón de reinicializa-
ción (RESET) Página 4
Tapa
Deslícela hacia abajo
para abrir
• Instale el soporte del con-
trolador remoto en un lugar
en el que la unidad interior
pueda recibir la señal.
Use únicamente el controlador remoto suministrado con la unidad.
No use otro controlador remoto.
Si dos o más unidades interiores están instaladas cerca unas de otras, puede
que la unidad que no se pretendía activar, responda al controlador remoto.
Unidad exterior
NOMBRE DE LAS PARTES
Unidad interior Controlador remoto
La apariencia de las unidades exteriores puede ser diferente.
Botón SMART SET (SELECCIÓN
INTELIGENTE) Página 6
Defl ector
horizontal
Salida de aire
Filtro de aire (fi ltro
de nanoplatino)
Entrada de
aire
Panel frontal
Botón de
desconexión
automática
(ECONO COOL)
Página 7
Filtro de limpieza de
aire (Filtro de enzi-
mas antialérgico)
Sección de pantalla
Interruptor de accionamiento
de emergencia
Página 5
Luz de indicación del funcio-
namiento
Sección de recepción del
controlador remoto
Intercambiador
de calor
Botón OFF/ON
(desactivación/
activación de
funcionamiento)
Indicador de
sustitución de las
pilas
Página 4
Sp-4
• Asegúrese de que la polaridad de las pilas es la correcta.
• No utilice pilas de manganeso o pilas con fugas. El controlador remoto
podría funcionar inadecuadamente.
• No utilice pilas recargables.
• El indicador de sustitución de las pilas se ilumina cuando las pilas tienen
poca carga. El controlador remoto dejará de funcionar al cabo de aproxi-
madamente 7 días desde que el indicador se ilumina por primera vez.
• Sustituya todas las pilas por otras nuevas de la misma clase.
Las pilas pueden durar 1 año aproximadamente. Ahora bien, las pilas
caducadas pueden durar menos.
• Pulse RESET (reiniciar) suavemente utilizando un objeto en punta.
Si no se pulsa el botón de reinicialización (RESET), el controlador remoto
no funcionará correctamente.
Antes de la puesta en marcha: inserte el enchufe de alimentación en la
toma de corriente y/o encienda el disyuntor.
Instalación de las pilas del controlador remoto
PREPARACIÓN ANTES DE LA PUESTA EN MARCHA
Pulse CLOCK (temporizador) suavemente utilizando
un objeto en punta.
Ajuste de la hora actual
Cambio de unidades de temperatura
(
˚
F→
˚
C)
La unidad esta confi gurada por defecto con °F.
1.
Pulse RESET (reini-
ciar) con los botones
de temperatura
pulsados.
Pulse RESET (reiniciar) suavemente utilizando un objeto en punta.
Para cambiar la unidad de temperatura de °C a °F, pulse RESET.
1.
Retire la tapa frontal.
3.
Coloque la tapa frontal.
4.
Pulse RESET.
1.
Pulse CLOCK
(temporizador).
3.
Pulse otra vez
CLOCK
(temporizador).
2.
Pulse los botones de TIME
para ajustar la hora.
Cada pulsación aumenta/dis-
minuye la hora en 1 minuto (10
minutos cuando la pulsación
es prolongada).
2.
Inserte primero el polo
negativo de las pilas
alcalinas tipo AAA.
Sp-5
● MANUAL DE INSTRUCCIONES ●
Modo I FEEL
La unidad selecciona el modo de funcionamiento en función de la tempe-
ratura ambiente cuando I FEEL está seleccionado. Cuando la temperatura
ambiente es superior a 77°F (25°C), se selecciona REFRIGERACIÓN
(temperatura establecida: 75°F [24°C]). Cuando la temperatura ambiente es
inferior a 77 ºF (25ºC), se selecciona DESHUMIDIFICACIÓN. Sin embargo,
cuando la unidad deja de funcionar y vuelve a ponerse en marcha antes de
2 horas, se activa el modo que estaba seleccionado previamente.
Nota:
Mientras funciona en el modo REFRIGERACIÓN, es posible que no se
cambie la temperatura establecida si la temperatura ambiente la supera
en más de 4ºF (2ºC). En este caso, espere hasta que la temperatura
ambiente descienda hasta 4ºF (2ºC) por debajo de la temperatura esta-
blecida.
Modo de REFRIGERACIÓN
Disfrute de aire frío a la temperatura que desee.
Nota:
No ponga en funcionamiento el modo de REFRIGERACIÓN con tempera-
turas muy bajas en el exterior (inferior a 14°F [-10°C]). El agua condensa-
da en la unidad puede gotear y humedecer o dañar el mobiliario, etc.
Modo de DESHUMIDIFICACIÓN
Deshumedezca su habitación. Puede refrigerarla ligeramente.
La temperatura no se puede ajustar mientras el aparato está en el modo
de DESHUMIDIFICACIÓN.
Modo de VENTILADOR
Haga circular el aire en la habitación.
Luz de indicación de funcionamiento
Funcionamiento de emergencia
Si no se puede utilizar el controlador remoto...
Se puede activar el funcionamiento de emergencia pulsando el interruptor de
accionamiento de emergencia (E.O.SW) en la unidad interior.
Cada vez que se pulsa el interruptor de accionamiento
de emergencia (E.O.SW), el funcionamiento cambia en el
orden siguiente:
1
Pulse
para que se ponga en funcionamiento.
2
Pulse para seleccionar el modo de funciona-
miento. El modo cambia con cada pulsación de la
manera siguiente:
3
Pulse o para ajustar la temperatura.
Cada pulsación eleva o disminuye la temperatura en
1°F (1°C).
Pulse para apagarlo.
Cuando vuelva a encenderlo, se activará la misma configuración se-
leccionada si pulsa
.
Función de reinicio automático
En caso de que se produzca un corte en el suministro eléctrico o se apague
la unidad mientras esté funcionando, la “Función de reinicio automático” se
activará automáticamente en el mismo modo seleccionado con el controlador
remoto antes de que se interrumpiese el funcionamiento. Cuando está confi -
gurado el temporizador, los ajustes se anulan y la unidad empieza a funcionar
al volver a encenderla.
Si no desea utilizar esta función, póngase en contacto con el servicio
técnico ya que tendrá que modifi car los ajustes de la unidad.
SELECCIÓN DE MODOS DE FUNCIONAMIENTO
Temperatura fi jada: 75°F (24°C)
Velocidad del ventilador: media
Defl ector horizontal: auto
REFRIGERACIÓN de emergencia
Parada
Nota:
Los primeros 30 minutos de funcionamiento son de prueba.
El control de temperatura no funciona y la velocidad del
ventilador está fi jada en “Alta”.
(VENTILADOR)
Luz de indicación de funcionamiento
La luz de indicación de funcionamiento muestra el estado de funcionamiento
de la unidad.
Indicación Estado de funcionamiento Temperatura ambiente
La unidad está en funcionamiento
para alcanzar la temperatura fi jada
Aproximadamente 4°F
(2°C) o más de diferencia
con la temperatura fi jada
La temperatura ambiente se acerca
a la temperatura fi jada
Aproximadamente de 2 a
4°F (1 a 2°C) de diferen-
cia con la temperatura
jada
Luz encendida Luz apagada
(I FEEL) (REFRIGERACIÓN) (DESHUMIDIFICACIÓN)
Sp-6
Pulse para seleccionar la velocidad del venti-
lador. La velocidad del ventilador cambia con cada
pulsación en el orden siguiente:
Al configurar la unidad interior en AUTO, se escuchan dos pitidos
cortos.
Utilice una velocidad de ventilador superior para enfriar la habitación
más rápidamente. Se recomienda reducir la velocidad del ventilador
una vez que la habitación se ha enfriado.
Utilice una velocidad de ventilador inferior para un funcionamiento
silencioso.
Pulse para seleccionar la dirección del aire. La
dirección del aire cambia con cada pulsación en el
orden siguiente:
Al configurar la unidad interior en AUTO, se escuchan dos pitidos
cortos.
(AUTO)
(Quiet [Silencioso])
(Baja) (Media) (Alta) (Muy alta)
(AUTO) (1) (2) (3) (4) (5) (
OSCILACIÓN
)
VELOCIDAD DEL VENTILADOR Y
AJUSTE DE LA DIRECCIÓN DEL AIRE
Dirección del flujo de aire
(AUTO) .............El deflector se ajusta en la dirección de flujo de aire que
ofrece un mayor rendimiento. : posición horizontal.
(Manual) ...........Para un mejor rendimiento del acondicionador de aire,
seleccione la posición superior para REFRIGERACIÓN/
DESHUMIDIFICACIÓN y la posición inferior para VENTI-
LADOR. Si se selecciona la posición (4) o (5) durante el
modo de REFRIGERACIÓN/DESHUMIDIFICACIÓN, el
deflector se desplaza automáticamente a la posición hacia
arriba pasado un período de 30 minutos a 1 hora para evitar
que gotee el agua de condensación.
(Oscilación) ......El deflector se desplaza hacia arriba y hacia abajo de
forma intermitente.
Para cambiar la dirección del fl ujo de aire.
Desplace el defl ector vertical manual antes de que empiece a funcionar el
acondicionador.
1
Pulse durante el modo de REFRIGERACIÓN o
DESCONEXIÓN AUTOMÁTICA (ECONO COOL) para
seleccionar el modo de SMART SET (SELECCIÓN
INTELIGENTE).
2
Establezca la temperatura, la velocidad del ventilador y
la dirección del fl ujo de aire.
La próxima vez que lo encienda, podrá seleccionar esta misma confi-
guración sólo con pulsar
.
Se puede guardar una configuración.
Seleccione la temperatura, la velocidad del ventilador y la dirección
del flujo de aire adecuadas para la habitación.
Vuelva a pulsar para cancelar el funcionamiento
SMART SET (SELECCIÓN INTELIGENTE).
El funcionamiento SMART SET (SELECCIÓN INTELIGENTE) tam-
bién se cancela al pulsar el botón MODE (MODO).
Funcionamiento SMART SET
(SELECCIÓN INTELIGENTE)
Mediante una sencilla función de selección previa se puede recordar la confi-
guración preferida (preestablecida) con sólo pulsar el botón
. Para volver a
la configuración anterior, vuelva a pulsar el botón.
Ejemplo de uso:
1. Modo de bajo consumo
Aumente la temperatura de 4°F (2°C) a 6°F (3°C) en modo de REFRIGE-
RACIÓN. Puede usar esta configuración para una habitación desocupada
o mientras duerme.
2. Guardar las configuraciones más frecuentes
Guarde sus confi guraciones preferidas para los modos de REFRIGERA-
CIÓN/DESCONEXIÓN AUTOMÁTICA (ECONO COOL). De esta forma, po-
drá seleccionar su confi guración preferida con solo pulsar un botón.
FUNCIONAMIENTO SMART
SET (SELECCIÓN INTELIGENTE)
Sp-7
● MANUAL DE INSTRUCCIONES ●
FUNCIONAMIENTO DEL TEMPORIZADOR (ACTI-
VACIÓN/DESACTIVACIÓN DEL TEMPORIZADOR)
1
Pulse o durante el funcionamiento para
ajustar el temporizador.
(ACTIVACIÓN del temporizador):
La unidad se encenderá a la hora
establecida.
(DESACTIVACIÓN del temporizador):
La unidad se apagará a la hora
establecida.
* o parpadea.
* Asegúrese de que la hora actual es la correcta. Página 4
2
Pulse (Aumentar) y (Disminuir) para ajustar
la hora del temporizador.
Con cada pulsación la hora establecida aumenta o disminuye en 10
minutos.
Ajuste el temporizador mientras
o parpadean.
3
Pulse o de nuevo para cancelar el tempo-
rizador.
Nota:
Los temporizadores de ON (encendido) y OFF (apagado) se pueden con-
gurar a la vez. La marca
muestra el orden en el que se activarán los
temporizadores.
Si se produce un corte en el suministro eléctrico mientras está confi gurado
el temporizador en ACTIVACIÓN/DESACTIVACIÓN, consulte la Página 5
“Función de reinicio automático”.
FUNCIONAMIENTO DE LA DESCON-
EXIÓN AUTOMÁTICA (ECONO COOL)
Pulse durante el modo de REFRIGERACIÓN
Página 5 para iniciar el funcionamiento de desco-
nexión automática (ECONO COOL).
La unidad realiza la operación de oscilación verticalmente en varios
ciclos según la temperatura del flujo de aire. La temperatura fijada
sube automáticamente 4°F (2°C).
Pulse otra vez para cancelar la operación ECO-
NO COOL.
El funcionamiento de DESCONEXIÓN AUTOMÁTICA (ECONO
COOL) también se puede cancelar pulsando el botón de DEFLEC-
TOR (VANE).
¿En qué consiste la función de
“desconexión automática (ECONO COOL)”?
Si la dirección del aire cambia cada cierto tiempo (vaivén del aire), el ambiente
se refresca más que si la dirección se mantiene siempre fi ja. Así pues, aunque
la temperatura establecida aumente automáticamente en 4°F (2°C), puede utili-
zar esta función cuando el aparato esté en modo de refrigeración y así sentirse
cómodo. Además, podrá ahorrar energía.
Sp-8
Instrucciones:
LIMPIEZA
Durante la limpieza, apague el disyuntor o desenchúfelo de la toma de
corriente.
Tenga cuidado de no tocar las partes metálicas con las manos.
No utilice bencina, polvo de pulimentación ni insecticida.
Use sólo detergentes suaves diluidos.
No exponga directamente al sol, al calor o a las llamas ninguna pieza con
el fi n de secarla.
No use agua con temperatura superior a 120°F (50°C).
1. Suba el panel frontal hasta que oiga un “clic”.
2. Sujete los goznes y tire de él para extraerlo, como se muestra en la ilustra-
ción anterior.
Pásele un paño suave seco o aclárelo con agua.
No lo empape en agua más de dos horas.
Séquelo bien en la sombra.
3. Instale el panel frontal siguiendo las instruc-
ciones de extracción en orden inverso. Cie-
rre el panel frontal de forma segura y pulse
las posiciones que indican las fl echas.
Panel frontal
Orifi cio
Gozne
Filtro de limpieza de aire
(Filtro de enzimas antialérgico)
Parte posterior del fi ltro de aire
Cada 3 meses:
Elimine la suciedad con un aspirador.
Si la suciedad no se puede eliminar con un aspirador:
Sumerja el ltro y su carcasa en agua emplada antes de enjuagarlos.
Tras el lavado, séquelo bien a la sombra.
Cada año:
Cambie el fi ltro de aire por uno nuevo para un mejor rendimiento.
Número de las piezas MAC-408FT-E
Tire para desacoplar del fi ltro de aire.
Importante
Limpie los ltros con regularidad para un mejor rendi-
miento y para reducir el consumo de electricidad.
Los ltros sucios pueden provocar condensación en
el acondicionador de aire que contribuye a la forma-
ción de hongos, como el moho. Por lo tanto, es reco-
mendable limpiar los fi ltros cada 2 semanas.
Filtro de aire (fi ltro de nanoplatino)
Límpielo cada 2 semanas
Elimine la suciedad con un aspirador o enjuáguelo con agua.
Después de limpiarlo con agua, déjelo secar completamente a la
sombra.
¿Qué es el “fi ltro de nanoplatino”?
El nanoplatino es una partícula cerámica que incluye una nanopartícula
de platino. Las partículas se incorporan al material del ltro, que tiene
como resultado proporcionar características antibacterias y desodoran-
tes semipermanentes al fi ltro. El nanoplatino sobrepasa en rendimiento
a los taninos (un biofl avonoide que se encuentra en el té verde). El ltro
de nanoplatino utiliza este compuesto para mejorar la calidad del aire y
también para eliminar bacterias y virus. Este ltro de aire tiene un efecto
de durabilidad semipermanente incluso tras lavarlo con agua.
Sp-9
● MANUAL DE INSTRUCCIONES ●
Si después de comprobar estas cuestiones el acondicionador de aire
sigue sin funcionar bien, póngase en contacto con su distribuidor.
Síntoma Explicación y puntos de comprobación
Unidad interior
La unidad no puede ponerse
en funcionamiento.
¿Está activado el disyuntor?
¿Está puesto el enchufe de la alimenta-
ción?
¿Está confi gurada la activación del tempo-
rizador? Página 7
El defl ector horizontal no se
mueve.
¿Está correctamente instalado el defl ector
horizontal?
¿Está deformado el protector del ventila-
dor?
Cuando se vuelve a poner en
marcha, la unidad tarda unos
3 minutos en funcionar.
Se trata de una instrucción del microproce-
sador para proteger la unidad. Espere.
El vapor se descarga a través
de la salida de aire de la
unidad interior.
El aire refrigerado de la unidad enfría
rápidamente la humedad del interior de la
habitación y la convierte en vapor.
La operación de oscilación
del DEFLECTOR HORIZON-
TAL se suspende durante un
tiempo y, a continuación, se
reanuda.
Es para que la operación de oscilación del
DEFLECTOR HORIZONTAL se realice con
normalidad.
La dirección del fl ujo de aire
cambia en pleno funciona-
miento.
La dirección del defl ector
horizontal no puede ajustarse
con el controlador remoto.
Cuando el aire acondicionado sigue funcio-
nando en los modos REFRIGERACIÓN o
DESHUMIDIFICACIÓN, después de llevar
entre 30 minutos y 1 hora expulsando el aire
hacia abajo, la dirección del fl ujo de aire se
ajusta directamente en la posición hacia
arriba para evitar que el agua condensada
gotee.
La unidad se pone en marcha
por sí misma al conectar la
alimentación principal, aun-
que no haya recibido la señal
del controlador remoto.
Estos modelos están equipados con la
función de reinicio automático. Cuando se
desconecta la alimentación principal sin
detener la unidad mediante el controlador
remoto y se vuelve a encender, la unidad
se pone en marcha automáticamente
en el mismo modo seleccionado con el
controlador remoto justo antes de que se
desconectara la alimentación principal.
Consulte “Función de reinicio automático”
Página 5 .
La unidad interior se decolora
con el tiempo.
Aunque, debido a agentes como la luz
ultravioleta y la temperatura, el plástico se
vuelva amarillo, esto no tendrá ningún efecto
en las funciones del producto.
Unidad exterior
El ventilador de la unidad
exterior no gira aunque el
compresor está funcionando.
Aunque el ventilador empiece
a girar, se para en seguida.
Cuando la temperatura exterior es baja
durante la operación de refrigeración, el
ventilador funciona intermitentemente para
mantener sufi ciente capacidad de enfria-
miento.
En la unidad exterior hay una
fuga de agua.
Durante la REFRIGERACIÓN o la DESHU-
MIDIFICACIÓN, el enfriamiento de los tubos
y de las conexiones de los tubos hace que
se condense el agua.
Controlador remoto
La pantalla del controlador
remoto no aparece o se
oscurece. La unidad interior
no responde a la señal del
controlador remoto.
¿Están agotadas las pilas? Página 4
¿Es correcta la polaridad (+, -) de las pilas?
Página 4
¿Se ha pulsado algún botón del controlador
remoto de otros aparatos eléctricos?
Síntoma Explicación y puntos de comprobación
No refrigera
La habitación no se refrigera
lo sufi ciente.
¿Es correcto el ajuste de la temperatura?
Página 5
¿Es adecuado el ajuste del ventilador? Cam-
bie la velocidad del ventilador a Alta o Muy Alta.
Página 6
¿Están limpios los fi ltros? Página 8
¿Están limpios el ventilador o el intercam-
biador de calor de la unidad interior?
¿Hay algún obstáculo que bloquee la entra-
da o salida de aire de las unidades interior
o exterior?
¿Se ha abierto una ventana o puerta?
Cuando se utiliza un ventilador de aire o una
cocina de gas en la habitación, aumenta la
carga de refrigeración, con lo cual el efecto
de refrigeración resulta insufi ciente.
Cuando la temperatura del aire exterior es
alta, el efecto de refrigeración puede resultar
insufi ciente.
Podría tardar cierto tiempo en alcanzar
la temperatura establecida o podría no
alcanzarse dependiendo del tamaño de
la habitación, la temperatura ambiente y
similares.
Flujo de aire
El aire de la unidad interior
tiene un olor raro.
¿Están limpios los fi ltros? Página 8
¿Están limpios el ventilador o el intercam-
biador de calor de la unidad interior?
La unidad puede absorber el olor adherido a
las paredes, alfombras, muebles, prendas,
etc. y expulsarlo junto con el aire.
Sonido
Se oye un ruido de rotura. Se trata de un sonido provocado por la
dilatación/contracción del panel frontal, etc.
a causa de los cambios de temperatura.
Se oye un ruido de “burbu-
jeo”.
Este ruido se oye cuando, al encenderse
la campana o el ventilador, la manguera de
drenaje absorbe aire del exterior y el agua
que fl uye por la manguera sale expulsada.
Este ruido también se oye cuando hace
mucho viento y entra aire en la manguera
de drenaje.
Se escucha un sonido mecá-
nico en la unidad interior.
Corresponde al sonido de encendido/apa-
gado del ventilador o del compresor.
Se oye correr agua. Se trata del ruido del refrigerante o del agua
condensada que fl uye por la unidad.
A veces se oye un silbido. Se trata del ruido que hace el refrigerante
al cambiar la dirección de la circulación en
el interior de la unidad.
En los casos siguientes pare el equipo y póngase en contacto con su
distribuidor.
Cuando cae o gotea agua de la unidad interior.
Cuando la luz de indicación de funcionamiento superior parpadea.
Cuando el disyuntor se desconecta con frecuencia.
Es posible que la señal del controlador remoto no se reciba en habitaciones
en las que se utilicen fl uorescentes de accionamiento electrónico (de tipo
inversor, etc.).
El funcionamiento del acondicionador de aire interfi ere con la capacidad de
recepción del televisor o la radio. Puede ser necesario conectar el receptor
afectado a un amplifi cador.
Si se oye un ruido anómalo.
Si se produce una fuga de refrigerante.
SI CREE QUE HA OCURRIDO ALGÚN PROBLEMA
Sp-10
ESPECIFICACIONES
Intervalo garantizado de funcionamiento
Interior Exterior
Refrige-
ración
Margen
superior
90°F (32,2°C) DB 115°F (46,1°C) DB
73°F (22,8°C) WB
Margen
inferior
67°F (19,4°C) DB 14°F (-10°C) DB
57°F (13,9°C) WB
DB : Temperatura seca
WB : Temperatura húmeda
Lugar de instalación
Procure no instalar el acondicionador de aire en los siguientes lugares.
Donde haya demasiado aceite para maquinaria.
En ambientes salobres, como las zonas costeras.
Donde haya gas sulfúrico, como en zonas de baños termales, alcantarillas
o aguas residuales.
Donde se haya derramado aceite o haya mucho humo aceitoso en el ambiente
(como en áreas donde se cocina o en fábricas, ya que las partes de plásti-
co podrían alterarse o dañarse en estos lugares).
Donde existe equipo inalámbrico o de alta frecuencia.
Donde el aire de la salida de aire de la unidad exterior esté bloqueado.
Donde el sonido del funcionamiento o el del aire de la unidad exterior
moleste a los vecinos.
Para el montaje de la unidad interior, se recomienda una altura de 5,9 pies
a 7,5 pies (de 1,8 m a 2,3 m). Si fuera imposible, consulte a su distribuidor.
Instalación eléctrica
Procure que el acondicionador de aire disponga de un circuito de alimenta-
ción exclusivo.
Procure que la capacidad del disyuntor sea la adecuada.
Si tiene alguna pregunta, consulte a su distribuidor.
LUGAR DE INSTALACIÓN Y
TRABAJO ELÉCTRICO
Para evitar los efectos
de una lámpara fl uores-
cente, manténgase lo
más alejado posible.
pared, etc.
Lámpara fl uorescente
de tipo inversor
Mantenga un
espacio sufi ciente
para evitar
distorsiones
en imágenes o
sonido.
3 pies
(1 m) o
más
Radio
4 pulg.
(100 mm)
o más
Para obtener la máxima
efi ciencia y prolongar
la vida útil de la unidad
exterior, esta debe insta-
larse en un sitio seco y
bien ventilado.
8 pulg.
(200 mm)
o más
Televisión
Teléfono
inalám-
brico o
portátil
10 pies
(3 m)
o más
3 pies
(1 m) o
más
La unidad exterior debe instalarse por lo menos a 10 pies
(3 m) de las antenas para equipos de televisión, radio,
etc. En zonas de mala recepción, si el funcionamiento
del acondicionador de aire interfi ere en la recepción de
emisoras de radio o de televisión, aumente la separación
entre la unidad exterior y la antena del aparatoafectado.
1
Ajuste a la máxima temperatura en el modo manual de
REFRIGERACIÓN, y déjelo en funcionamiento durante
3 a 4 horas. Página 5
Esto hace que se seque el interior de la unidad.
La humedad condensada en el aparato de aire acondicionado pue-
de contribuir a la formación y expansión de hongos, como el moho.
2
Pulse
para que se detenga.
3
Desconecte el disyuntor o desconecte el enchufe de la
alimentación.
4
Quite todas las pilas del controlador remoto.
Al volver a usar el acondicionador de aire:
1
Limpie el fi ltro del aire. Página 8
2
Compruebe que no estén bloqueadas las entradas y
salidas de aire de las unidades interior/exterior.
3
Compruebe que el cable de tierra esté conectado
correctamente.
4
Consulte la sección “PREPARACIÓN ANTES DE LA
PUESTA EN MARCHA” y siga las instrucciones.
Página 4
CUANDO EL ACONDICIONADOR DE AIRE NO SE
VAYA A UTILIZAR DURANTE MUCHO TIEMPO
Nota:
1. El valor del intervalo garantizado de funcionamiento es para la aplicación corres-
pondiente al sistema 1:1.
2. Si la temperatura exterior se encuentra por debajo del margen inferior del inter-
valo garantizado de funcionamiento, es posible que la unidad exterior detenga el
funcionamiento hasta que la temperatura exterior supere el margen inferior.
Fr-1
● NOTICE D’UTILISATION ●
Avant toute utilisation, veuillez lire les “Consignes de sécurité” car cet
appareil contient des pièces rotatives ou autres pouvant entraîner des
risques d’électrocution.
Les consignes contenues dans cette section sont importantes pour la
sécurité et doivent donc impérativement être respectées.
Après avoir lu cette notice, conservez-la avec le manuel d’installation à
portée de main pour pouvoir la consulter aisément.
Veillez à recevoir une carte de garantie de votre revendeur et vérifi ez que
la date d’achat et le nom du magasin, etc. sont saisis correctement.
Symboles et leur signifi cation
AVERTISSEMENT:
toute manipulation incorrecte peut avoir des
conséquences graves, provoquer des blessures
corporelles voire la mort de l’utilisateur.
PRECAUTION:
toute manipulation incorrecte peut avoir des consé-
quences graves selon les circonstances.
Signifi cation des symboles utilisés dans ce manuel
: à éviter absolument.
: suivre rigoureusement les instructions.
: ne jamais insérer le doigt ou un objet long, etc.
: ne jamais monter sur l’unité interne/externe et ne rien poser dessus.
: risque d’électrocution ! Attention !
: veiller à débrancher la fi che d’alimentation électrique de la prise
secteur.
: couper l’alimentation au préalable.
CONSIGNES DE SECURITE
TABLE DES MATIERES
AVERTISSEMENT
Ne pas utiliser de raccord intermédiaire ou de rallonge
pour brancher le cordon d’alimentation et ne pas brancher
plusieurs appareils à une même prise secteur.
Ceci pourrait provoquer une surchauffe de l’appareil, un
incendie ou un risque d’électrocution.
Nettoyer la che d’alimentation électrique et l’insérer
prudemment dans la prise secteur.
Une che d’alimentation électrique encrassée peut entraîner
un risque d’incendie ou d’électrocution.
Ne pas enrouler, tendre de façon excessive, modifi er ou
chauffer le cordon d’alimentation, et ne rien poser dessus.
Ceci pourrait provoquer un risque d’incendie ou d’électrocution.
Ne pas enclencher/couper le disjoncteur ou débrancher/brancher la che
d’alimentation électrique pendant le fonctionnement de l’appareil.
Des étincelles pourraient se produire et provoquer un risque d’incendie.
Toujours couper le disjoncteur ou débrancher la che d’alimentation
électrique suite à l’arrêt de l’unité interne avec la télécommande.
Il est déconseillé à toute personne de s’exposer au ux
d’air froid pendant une période prolongée.
Ceci pourrait entraîner des problèmes de santé.
L’utilisateur ne doit en aucun cas installer, déplacer, dé-
monter, modifi er ou tenter de réparer le climatiseur.
Toute manipulation incorrecte du climatiseur pourrait provo-
quer un risque d’incendie, d’électrocution, de blessure ou de
fuite d’eau, etc. Contacter un revendeur.
Si le cordon d’alimentation est endommagé, il doit être rem-
placé par le fabricant ou le service après-vente du fabricant
pour éviter tout risque potentiel.
Lors de l’installation, du déplacement ou de l’entretien de l’ap-
pareil, veiller à ce qu’aucune substance autre que le réfrigérant
spécifi é (R410A) ne pénètre dans le circuit de réfrigération.
La présence d’une substance étrangère, comme de l’air dans
le circuit, peut provoquer une augmentation anormale de la
pression et causer une explosion, voire des blessures.
L’utilisation de réfrigérant autre que celui qui est spécifi é
pour le système provoquera une défaillance mécanique,
un mauvais fonctionnement du système, ou une panne de
l’appareil. Dans le pire des cas, la sécurité du produit pourrait
être gravement mise en danger.
Cet appareil n’est pas conçu pour être utilisé par des
personnes (y compris des enfants) présentant des capa-
cités physiques, sensorielles ou mentales réduites, ou
manquant d’expérience et de connaissances, à moins
qu’elles ne soient supervisées ou aient reçu des instruc-
tions relatives à l’utilisation de l’appareil par une personne
responsable de leur sécurité.
Les enfants doivent être surveillés de manière à ce qu’ils
ne puissent pas jouer avec l’appareil.
Ne jamais insérer le doigt ou tout autre objet dans les
entrées ou sorties d’air.
La vitesse de rotation extrêmement rapide du ventilateur
pendant le fonctionnement du climatiseur pourrait provoquer
un accident.
En cas d’anomalie (odeur de brûlé, etc.), arrêter le clima-
tiseur et débrancher la che d’alimentation électrique ou
couper le disjoncteur.
Si le climatiseur continue à fonctionner en présence d’une
anomalie, une défaillance technique, un risque d’incendie ou
d’électrocution ne sont pas à exclure. Dans ce cas, consulter
un revendeur agréé.
Si la fonction de refroidissement ou de chauffage du clima-
tiseur est inopérante, cela peut indiquer la présence d’une
fuite de réfrigérant. Dans ce cas, consulter un revendeur
agréé. Si la réparation consiste à recharger l’appareil en
réfrigérant, demander conseil auprès d’un technicien
responsable de l’entretien.
Le réfrigérant contenu dans le climatiseur ne pose aucun
problème de sécurité. En règle générale, aucune fuite ne
doit se produire. Cependant, si le réfrigérant fuit et entre en
contact avec la partie chauffante d’un appareil de chauffage
à ventilation, d’un chauffage d’appoint, d’une cuisinière, etc.,
des substances toxiques se produiront.
L’utilisateur ne doit jamais procéder au nettoyage intérieur
de l’unité interne. Si vous pensez que la partie intérieure
de l’unité doit être nettoyée, veuillez contacter votre re-
vendeur.
L’utilisation d’un détergent inapproprié pourrait endommager
les surfaces intérieures en plastique de l’unité et provoquer
des fuites d’eau. Tout contact entre le détergent et les pièces
électriques ou le moteur pourrait entraîner un dysfonction-
nement, l’émission de fumées, voire un incendie.
CONSIGNES DE SECURITE 1
NOMENCLATURE 3
PREPARATIF D’UTILISATION 4
SELECTION DES MODES DE FONCTIONNEMENT 5
REGLAGE DE LA VITESSE DU VENTILATEUR ET DE LA DIRECTION DU FLUX D’AIR 6
MODE SMART SET (REGLAGE INTELLIGENT) 6
FONCTIONNEMENT EN MODE ECONO COOL 7
FONCTIONNEMENT DE LA MINUTERIE (MARCHE/ARRET) 7
NETTOYAGE 8
EN PRESENCE D’UNE PANNE POTENTIELLE 9
SI LE CLIMATISEUR DOIT RESTER LONGTEMPS INUTILISE 10
LIEU D’INSTALLATION ET TRAVAUX ELECTRIQUES 10
FICHE TECHNIQUE 10
Fr-2
CONSIGNES DE SECURITE
PRECAUTION
Ne pas toucher à l’entrée d’air ou aux ailettes en aluminium
de l’unité interne/externe.
Risque de blessures.
Ne vaporiser ni insecticide ni substance infl ammable sur
l’appareil.
Ceci pourrait provoquer un incendie ou une déformation de
l’appareil.
Ne pas exposer un animal domestique ou une plante d’inté-
rieur directement sous le courant d’air pulsé.
Le bien-être des animaux et des plantes pourrait en être
affecté.
Ne placer ni appareil électrique ni meuble sous l’unité
interne/externe.
De l’eau pourrait s’écouler de l’appareil et les endommager
ou provoquer une panne de leur système.
Ne jamais laisser le climatiseur posé sur un support en-
dommagé.
Il pourrait tomber et provoquer un accident.
Veiller à ne pas monter sur une surface instable pour allumer
ou nettoyer le climatiseur.
Risque de chute et de blessures.
Ne jamais tirer sur le cordon d’alimentation.
Le l central du cordon d’alimentation pourrait se rompre et
provoquer un incendie.
Ne jamais recharger ou tenter d’ouvrir les piles et ne pas
les jeter au feu.
Les piles pourraient fuir et présenter un risque d’incendie ou
d’explosion.
Ne pas faire fonctionner le climatiseur pendant plus de 4
heures avec un taux d’humidité important (80% HR ou plus),
et/ou lorsqu’une porte ou une fenêtre est ouverte.
Ceci peut provoquer de la condensation à l’intérieur du clima-
tiseur, qui risque de s’écouler et de mouiller ou d’endommager
le mobilier.
La présence d’humidité dans la climatisation peut contribuer
à la croissance de certains champignons tels que la moisis-
sure.
Ne pas utiliser le climatiseur pour conserver des aliments,
élever des animaux, faire pousser des plantes, ranger des
outils de précision ou des objets d’art.
Leur qualité pourrait s’en ressentir, et le bien-être des animaux
et des plantes pourrait en être affecté.
Ne pas exposer des appareils à combustion directement
sous la sortie d’air pulsé.
Une combustion imparfaite pourrait en résulter.
Ne mettez jamais des piles dans la bouche pour quelque
raison que ce soit pour éviter de les avaler par accident.
Le fait d’ingérer des piles peut entraîner un étouffement et/ou
un empoisonnement.
Avant de procéder au nettoyage du climatiseur, le mettre
hors tension et débrancher la che d’alimentation électrique
ou couper le disjoncteur.
La vitesse de rotation extrêmement rapide du ventilateur
pendant le fonctionnement du climatiseur pourrait provoquer
un accident.
Si le climatiseur doit rester inutilisé pendant une période
prolongée, débrancher la che d’alimentation électrique ou
couper le disjoncteur.
Il pourrait s’encrasser et présenter un risque d’incendie ou
d’électrocution.
Remplacer les piles de la télécommande par des piles neuves
du même type.
Ne jamais mélanger piles usagées et piles neuves ; ceci pour-
rait provoquer une surchauffe, une fuite ou une explosion.
Si du liquide provenant des piles entre en contact avec la
peau ou les vêtements, les rincer abondamment à l’eau
claire.
Si du liquide alcalin entre en contact avec les yeux, les rincer
abondamment à l’eau claire et contacter d’urgence un méde-
cin.
Si le climatiseur est utilisé conjointement avec un appareil
à combustion, veiller à ce que la pièce soit parfaitement
ventilée.
Une ventilation insuffi sante pourrait provoquer un manque
d’oxygène dans la pièce.
Couper le disjoncteur par temps d’orage.
La foudre pourrait endommager le climatiseur.
AVERTISSEMENT
Consulter un revendeur agréé pour qu’il procède à l’instal-
lation du climatiseur.
L’utilisateur ne doit en aucun cas tenter d’installer le climatiseur
lui-même ; seul du personnel qualifi é et compétent est en
mesure de le faire. Toute installation incorrecte du climatiseur
pourrait être à l’origine de fuites d’eau et provoquer un risque
d’incendie ou d’électrocution.
Prévoir un circuit réservé à l’alimentation du climatiseur.
Dans le cas contraire, un risque de surchauffe ou d’incendie
n’est pas à exclure.
Ne pas installer l’appareil dans un endroit susceptible d’être
exposé à des fuites de gaz infl ammable.
L’accumulation de gaz autour de l’appareil entraîne des risques
d’explosion.
Raccorder correctement le climatiseur à la terre.
Ne jamais raccorder le câble de terre à un tuyau de gaz, une
évacuation d’eau, un paratonnerre ou un câble téléphonique
de mise à la terre. Une mise à la terre incorrecte pourrait
provoquer un risque d’électrocution.
PRECAUTION
Installer un disjoncteur de fuites à la terre selon l’endroit
le climatiseur sera monté (pièce humide par ex.).
L’absence de disjoncteur de fuites à la terre peut entraîner un
risque d’électrocution.
Veiller à ce que l’eau de vidange s’écoule correctement.
Si l’écoulement des condensats est bouché, l’eau de vidange
risque de s’écouler de l’unité interne/externe et d’endommager
le mobilier.
En présence d’une situation anormale
Arrêter immédiatement le climatiseur et consulter un revendeur agréé.
Si le climatiseur a été utilisé pendant plusieurs saisons
consécutives, procéder à une inspection et à un entretien
rigoureux en plus du nettoyage normal.
Une accumulation de saletés ou de poussière à l’intérieur
du climatiseur peut être à l’origine d’une odeur désagréable,
contribuer au développement de moisissures ou bloquer
l’écoulement des condensats et provoquer une fuite d’eau de
l’unité interne. Consulter un revendeur agréé pour procéder
à une inspection et des travaux d’entretien nécessitant l’inter-
vention de personnel qualifi é et compétent.
Ne pas actionner les commandes du climatiseur avec les
mains mouillées.
Risque d’électrocution !
Ne pas nettoyer le climatiseur avec de l‘eau et ne placer ni
vase ni verre d’eau dessus.
Ceci pourrait provoquer un risque d’incendie ou d’électrocu-
tion.
Ne jamais marcher sur l’unité externe et ne rien poser
dessus.
Risque de chute et de blessures.
A propos de l’installation
IMPORTANT
Des ltres encrassés peuvent provoquer de la condensation dans le
climatiseur, ce qui contribuera à la croissance de certains champi-
gnons tels que la moisissure. Il est donc recommandé de nettoyer les
ltres à air toutes les 2 semaines.
Fr-3
● NOTICE D’UTILISATION ●
Entrée d’air
(arrière et latérale)
Conduite de réfrigérant
Tuyau d’évacuation des
condensats
Sortie d’air
Sortie de condensats
Support de la
télécommande
Transmission des
signaux
Distance de réception
du signal :
Environ 20 ft. (6 m)
L’émission de bip(s) en
provenance de l’unité in-
terne indique la réception
d’un signal.
Affi chage du
mode de fonction-
nement
Témoin de rem-
placement de la
pile
Page 4
Touche Arrêt/
Marche (OFF/
ON)
Touches de réglage de
la température
Pages 4, 5
Touche de sélec-
tion du mode de
fonctionnement
Page 5
Touche de ré-
glage de vitesse
du VENTILA-
TEUR Page 6
Touche d’arrêt (OFF) de
la minuterie Page 7
Touche de démarrage (ON)
de la minuterie
Page 7
Touches de réglage de l’heure (TIME) Pages 4, 7
Avancer
Reculer
Touche de réglage de
l’horloge (CLOCK) Page 4
Touche de réinitialisation (RESET) Page 4
Couvercle
Le faire coulisser vers le
bas pour l’ouvrir
Installez le support de la
télécommande de façon
à ce que l’unité interne
puisse recevoir les signaux.
Utilisez uniquement la télécommande fournie avec le climatiseur.
N’en utilisez pas d’autres.
Si plusieurs unités internes sont installées côté à côte, il se peut que le signal
envoyé à une unité interne par la télécommande soit exécuté par une autre
unité interne.
Unité externe
NOMENCLATURE
Unité interne Télécommande
L’apparence des unités externes peut varier d’un modèle à l’autre.
Touche SMART SET
Page 6
Affi chage
Témoin de fonctionnement
Récepteur de
télécommande
Interrupteur de secours
Page 5
Ailette
horizontale
Sortie d’air
Filtre à air (fi ltre
nano-platinum)
Entrée d’air
Panneau frontal
Filtre d’épuration
d’air (fi ltre antialler-
gique à enzymes)
Touche
de
refroidissement
économique
(ECONO
COOL)
Page 7
Touche
de commande
des AILETTES
Page 6
Echangeur
thermique
Fr-4
• Veillez à respecter la polarité des piles.
• N’utilisez pas de piles au manganèse ou des piles qui présentent une
fuite. Elles pourraient provoquer un dysfonctionnement de la télécom-
mande.
• N’utilisez pas de piles rechargeables.
• Le témoin de remplacement de la pile s’allume lorsque la pile est presque
déchargée. La télécommande cesse de fonctionner environ 7 jours après
l’activation du témoin.
• Remplacez toutes les piles par des piles de même type.
La durée de vie des piles est de 1 an environ. Cependant, les piles dont
la date d’utilisation est dépassée durent moins longtemps.
Appuyez doucement sur RESET à l’aide d’un instrument fi n.
Si la touche RESET n’est pas enfoncée, la télécommande risque de ne
pas fonctionner correctement.
Avant la mise en marche : Insérez la fi che d’alimentation électrique dans la
prise secteur et/ou enclenchez le disjoncteur.
Insertion des piles dans la télécommande
PREPARATIF D’UTILISATION
Appuyez doucement sur CLOCK à l’aide d’un instrument
fi n .
Réglage de l’heure
Changement des unités de température
(
˚
F→
˚
C)
L’unité prédéfi nie est °F.
1.
Appuyez sur RESET
lorsque vous enfon-
cez les touches de
température.
Appuyez doucement sur RESET à l’aide d’un instrument fi n.
Pour changer l’unité de la température entre degrés Celsius (°C) et degrés
Fahrenheit (°F), appuyez sur la touche RESET.
1.
Retirez le couvercle
avant.
3.
Posez le couvercle avant.
4.
Appuyez sur la
touche RESET.
1.
Appuyez sur la
touche CLOCK.
3.
Appuyez à nouveau
sur la touche CLOCK.
2.
Appuyez sur les touches TIME
pour régler l’heure.
A chaque pression sur ces
touches, l’heure augmente/
diminue de 1 minute (10
minutes lors d’une pression
prolongée).
2.
Insérez les piles alca-
lines AAA en plaçant
d’abord le pôle négatif.
Fr-5
● NOTICE D’UTILISATION ●
Mode de SENSATION (I FEEL)
Le climatiseur sélectionne le mode de fonctionnement selon la température
de la pièce si le mode de SENSATION est activé. Si la température de la
pièce est supérieure à 77°F (25°C), le mode de REFROIDISSEMENT est
sélectionné (température programmée : 75°F [24°C]). Si elle est inférieure à
77°F (25°C), le mode de DESHUMIDIFICATION est sélectionné. Toutefois,
si le climatiseur est arrêté, puis redémarré dans les 2 heures, il fonctionnera
dans le mode sélectionné précédemment.
Remarque :
En mode de REFROIDISSEMENT, la température programmée peut ne
pas changer si la température de la pièce est supérieure de 4°F (2°C) à la
température programmée. Dans ce cas, attendez que la température de la
pièce soit proche de 4°F (2°C) de la température programmée.
Mode de REFROIDISSEMENT
Le confort de l’air frais à votre température.
Remarque :
Ne faites pas fonctionner le climatiseur en mode de REFROIDISSEMENT
lorsque les températures extérieures sont extrêmement basses. (infé-
rieure à 14°F [-10°C]). L’eau de condensation présente à l’intérieur ducli-
matiseur risque de s’écouler et d’endommager le mobilier, etc.
Mode de DESHUMIDIFICATION
Eliminez l’humidité de votre pièce. Il se peut que la pièce refroidisse
légèrement.
Il n’est pas possible de régler la température en mode de DESHUMIDI-
FICATION.
Mode de VENTILATEUR
Permet de faire circuler l’air dans la pièce.
Témoin de fonctionnement
Fonctionnement d’urgence
Lorsqu’il est impossible d’utiliser la télécommande...
Vous pouvez lancer le fonctionnement d’urgence en appuyant sur l’interrup-
teur de secours (E.O.SW) de l’unité interne.
A chaque fois que vous appuyez sur l’interrupteur de
secours (E.O.SW), le fonctionnement du climatiseur change
dans l’ordre suivant :
1
Appuyez sur la touche
pour lancer le fonctionne-
ment du climatiseur.
2
Appuyez sur la touche pour sélectionner le mode
de fonctionnement. Chaque nouvelle pression sur cette
touche vous permet de passer d’un mode à l’autre
dans l’ordre suivant :
3
Appuyez sur les touches ou pour régler la tempé-
rature.
Chaque nouvelle pression sur ces touches vous per-
met d’augmenter ou de diminuer la température de 1°F
(1°C).
Appuyez sur la touche pour arrêter le fonctionne-
ment du climatiseur.
Vous avez la possibilité de recouvrer les mêmes réglages lors de la
prochaine utilisation du climatiseur en appuyant simplement sur
.
Fonction de redémarrage automatique
En cas de coupure d’électricité ou d’interruption de l’alimentation principale
pendant le fonctionnement du climatiseur, la “fonction de redémarrage auto-
matique” prend automatiquement le relais et permet de remettre le climatiseur
en marche en respectant le mode sélectionné à l’aide la télécommande juste
avant la coupure de l’alimentation. Si vous avez recours au fonctionnement
manuel de la minuterie, le réglage de la minuterie sera annulé et le climatiseur
redémarrera au retour de l’alimentation.
Si vous ne voulez pas utiliser cette fonction, veuillez vous adresser
au représentant du service technique afi n qu’il modifi e le réglage du
climatiseur.
SELECTION DES MODES DE FONCTIONNEMENT
Température programmée: 75°F (24°C)
Vitesse du ventilateur: moyenne
Ailette horizontale: auto
(VENTILATEUR)
REFROIDISSEMENT d’urgence
Arrêt
Remarque :
Les premières 30 minutes de fonctionnement constitue un es-
sai de fonctionnement. La commande de température ne fonc-
tionne pas, et la vitesse du ventilateur est réglée sur Rapide.
(SENSATION) (REFROIDISSEMENT) (DESHUMIDIFICATION)
Témoin de fonctionnement
Le témoin de fonctionnement indique l’état de fonctionnement du climatiseur.
Témoin Etat de fonctionnement Température de la pièce
Le climatiseur fonctionne de façon
à atteindre la température pro-
grammée
Environ 4°F (2°C) d’écart
minimum avec la tempé-
rature programmée
La température de la pièce se
rapproche de la température pro-
grammée
Environ 2 à 4°F (1 à 2°C)
d’écart avec la tempéra-
ture programmée
Allumé Eteint
Fr-6
Appuyez sur la touche pour sélectionner la
vitesse du ventilateur. Chaque nouvelle pression sur
cette touche vous permet de modifi er la vitesse du
ventilateur dans l’ordre suivant :
L’unité interne émet deux bips courts lorsqu’elle est réglée en mode
AUTO.
Augmentez la vitesse du ventilateur pour refroidir la pièce plus rapi-
dement. Il est recommandé de réduire la vitesse du ventilateur dès
que la pièce est fraîche.
Diminuez la vitesse du ventilateur pour un fonctionnement silencieux.
Appuyez sur la touche pour sélectionner la direc-
tion du fl ux d’air. Chaque nouvelle pression sur cette
touche vous permet de modifi er la direction du fl ux d’air
dans l’ordre suivant :
L’unité interne émet deux bips courts lorsqu’elle est réglée en mode
AUTO.
(AUTO) (Silencieux) (Faible) (Moy.) (Elevée) (Très élevée)
(AUTO) (1) (2) (3) (4) (5) (
OSCILLATION
)
REGLAGE DE LA VITESSE DU VENTILA-
TEUR ET DE LA DIRECTION DU FLUX D’AIR
Direction du flux d’air
(AUTO) ..........
L’ailette est réglée pour fournir la direction de flux d’air la
plus efficace. : position horizontale.
(Manuel) ........Pour une climatisation efficace, sélectionnez la position
supérieure pour le mode REFROIDISSEMENT/DESHUMI-
DIFICATION et la position inférieure pour la VENTILATION.
Si la position (4) ou (5), est sélectionnée en mode de RE-
FROIDISSEMENT/DESHUMIDIFICATION, l’ailette se place
automatiquement en position vers le haut au bout de 0,5 à 1
heure pour éviter la formation de gouttes de condensation.
(Oscillation) ...L’ailette se déplace de haut en bas par intermittence.
Pour modifi er la direction horizontale du fl ux d’air.
Déplacez manuellement l’ailette verticale avant de faire fonctionner le clima-
tiseur.
1
Appuyez sur en mode REFROIDISSEMENT ou
ECONO COOL pour sélectionner le mode SMART SET
(REGLAGE INTELLIGENT).
2
Réglez la température, la vitesse du ventilateur et la
direction du fl ux d’air.
Pour sélectionner les mêmes réglages par la suite, il vous suffira d’ap-
puyer sur
.
Il est possible d’enregistrer un jeu de réglages.
Sélectionnez la température, la vitesse du ventilateur et la direction du
flux d’air appropriées pour votre local.
Appuyez une nouvelle fois sur pour annuler le
mode SMART SET (REGLAGE INTELLIGENT).
Une pression sur la touche MODE permet également d’annuler le
mode SMART SET (REGLAGE INTELLIGENT).
MODE SMART SET
(REGLAGE INTELLIGENT)
Une fonction programmable simplifiée permet de rappeler le réglage favori (pré-
programmé) à l’aide d’une simple pression sur la touche
. Une seconde
pression sur la touche permet de revenir instantanément au réglage précédent.
Exemple d’utilisation:
1. Mode économie d’énergie
Augmentez la température de 4°F (2°C) à 6°F (3°C) en mode REFROIDIS-
SEMENT. Ce réglage convient pour les pièces inoccupées ou pendant la
nuit.
2. Enregistrement des paramètres fréquemment utilisés
Enregistrez votre réglage préféré pour le mode REFROIDISSEMENT/ECO-
NO COOL. Il vous suffi ra ensuite d’une simple pression sur la touche pour
rappeler votre réglage favori.
MODE SMART SET
(REGLAGE INTELLIGENT)
Fr-7
● NOTICE D’UTILISATION ●
1
Appuyez sur les touches ou pendant le
fonctionnement du climatiseur pour régler la minuterie.
(Démarrage de la minuterie [ON]) :
Le climatiseur démarrera (ON) à
l’heure programmée.
(Arrêt de la minuterie [OFF]) :
Le climatiseur s’arrêtera (OFF) à
l’heure programmée.
* ou clignote.
* La minuterie doit être réglée à l’heure juste. Page 4
2
Appuyez sur les touches (Augmenter) et
(Diminuer) pour régler l’heure de la minuterie.
Chaque pression sur ces touches vous permet de faire avancer ou
reculer l’heure programmée de 10 minutes.
Réglez la minuterie lorsque
ou clignote.
3
Appuyez à nouveau sur les touches ou
pour annuler le fonctionnement de la minuterie.
Remarque :
Les fonctions de démarrage (ON) et d’arrêt (OFF) de la minuterie peuvent
être réglées conjointement. Le symbole
indique l’ordre d’application des
modes de fonctionnement de la minuterie.
En cas de coupure d’électricité survenant après le réglage de la minuterie
(MARCHE/ARRET), voir Page 5 “Fonction de redémarrage automatique”.
FONCTIONNEMENT EN MODE
ECONO COOL
Appuyez sur la touche en mode de REFROI-
DISSEMENT Page 5 pour lancer le fonctionnement
ECONO COOL.
L’unité effectue un balayage oscillant vertical en différents cycles en
fonction de la température du flux d’air. La température programmée
est automatiquement réglée à 4°F (2°C) au-dessus de la température
normale.
Appuyez à nouveau sur la touche pour annuler
le fonctionnement en mode ECONO COOL.
La touche VANE permet également d’annuler le fonctionnement en
mode ECONO COOL.
Qu’est-ce que le mode de REFROIDISSEMENT
ECONOMIQUE “ECONO COOL” ?
L’oscillation de l’air pulsé (changement de direction) permet de rafraîchir davan-
tage une pièce qu’un ux d’air constant. Ainsi, même si la température pro-
grammée est automatiquement réglée 4°F (2°C) au dessus de la température
normale, il est possible d’utiliser le mode de refroidissement tout en conservant
un certain niveau de confort. De plus, vous économisez de l’énergie.
FONCTIONNEMENT DE LA MI-
NUTERIE (MARCHE/ARRET)
Fr-8
Instructions :
NETTOYAGE
Coupez l’alimentation ou le disjoncteur avant de procéder au nettoyage du
climatiseur.
Veillez à ne pas toucher les parties métalliques avec les mains.
N’utilisez ni benzine, ni diluant, ni poudre abrasive, ni insecticide.
Utilisez uniquement un détergent doux dilué avec de l’eau.
N’exposez pas les pièces aux rayons directs du soleil, à la chaleur ou à une
amme pour les faire sécher.
N’utilisez pas d’eau dont la température est supérieure à 120°F (50°C).
Panneau frontal
1. Soulevez le panneau frontal jusqu’à ce que vous entendiez un déclic.
2. Maintenez les charnières et tirez sur le panneau pour le retirer comme
indiqué sur l’illustration ci-dessus.
Essuyez-le avec un chiffon doux et sec ou lavez-le à l’eau.
Ne le faites pas tremper dans l’eau pendant plus de deux heures.
Faites-le sécher correctement à l’ombre.
3. Reposez le panneau frontal en suivant la pro-
cédure de dépose en sens inverse. Refermez
correctement le panneau frontal et appuyez
sur les repères indiqués par les fl èches.
Trou
Charnière
Important
Nettoyez régulièrement les ltres pour obtenir des
performances optimales et réduire votre consomma-
tion d’électricité.
Des ltres encrassés peuvent provoquer de la
condensation dans le climatiseur, ce qui contribuera
à la croissance de certains champignons tels que la
moisissure. Il est donc recommandé de nettoyer les
ltres à air toutes les 2 semaines.
Tirez sur le panneau frontal
pour le retirer du fi ltre à air.
Filtre d’épuration d’air
(fi ltre antiallergique à enzymes)
Envers du fi ltre à air
Tous les 3 mois :
Enlever la saleté à l’aide d
un aspirateur.
Lorsque cela ne suffi t pas :
Faites tremper le ltre et son cadre dans de l’eau tiède avant de les
nettoyer.
Lorsqu’ils sont propres, faites-les sécher correctement à l’ombre.
Tous les ans :
Pour des performances optimales, remplacer le fi ltre d’épuration d’air.
Référence MAC-408FT-E
Filtre à air (fi ltre nano-platinum)
Nettoyez toutes les 2 semaines.
Eliminez la saleté accumulée sur le fi ltre avec un aspirateur ou en
passant le fi ltre sous l’eau.
Après avoir passé le fi ltre sous l’eau, laissez-le sécher à l’ombre.
Qu’est-ce qu’un “fi ltre nano-platinum” ?
Le nano-platinum est une particule en céramique qui contient une nanoparticule de
platine. Ces particules sont incorporées au matériau du ltre dans le but d’offrir des
caractéristiques antibactériennes et désodorisantes semi-permanentes au ltre. Les
performances du nano-platinum dépassent de loin celles de la catéchine (un biofl avo-
noïde que l’on trouve dans le thé vert). Le fi ltre nano-platinum utilise cette substance
non seulement pour améliorer la qualité de l’air mais également pour éviter la proli-
fération de bactéries et de virus dans la pièce. Les caractéristiques de ce ltre à air
sont semi-permanentes, c’est-à-dire qu’elles se prolongent au-delà du nettoyage du
ltre à l’eau
.
Fr-9
● NOTICE D’UTILISATION ●
Suite à la vérifi cation de ces points, si le climatiseur ne fonctionne toujours
pas correctement, ne vous en servez plus et consultez votre revendeur.
Symptôme Explication & points à vérifi er
Unité interne
L’unité ne fonctionne pas.
Le disjoncteur est-il enclenché ?
La fi che d’alimentation est-elle branchée ?
La minuterie de mise en marche (ON) est-
elle programmée ? Page 7
L’ailette horizontale ne bouge
pas.
Les ailettes horizontales sont-elles installées
correctement ?
La grille de protection du ventilateur est-elle
déformée ?
L’unité ne peut pas être
remise en marche dans les 3
minutes qui suivent sa mise
hors tension.
Cette disposition a été prise pour protéger
le climatiseur conformément aux instructions
du microprocesseur. Veuillez patienter.
De la buée s’échappe de la
sortie d’air de l’unité interne.
L’air frais pulsé par le climatiseur refroidit
rapidement l’humidité présente dans la
pièce, et la transforme en buée.
L’oscillation de l’AILETTE
HORIZONTALE est suspen-
due un certain temps, puis
restaurée.
Cela permet l’oscillation correcte de l’AILET-
TE HORIZONTALE.
La direction de l’air pulsé va-
rie pendant le fonctionnement
de l’unité.
La télécommande ne permet
pas de régler la direction de
l’ailette horizontale.
Lorsque le climatiseur est en mode de
REFROIDISSEMENT ou de DESHUMIDI-
FICATION, s’il fonctionne en continu entre
0,5 et 1 heure avec le fl ux d’air orienté vers
le bas, la direction de l’air pulsé est automa-
tiquement placée en position vers le haut
afi n d’empêcher l’eau de condensation de
s’écouler.
L’unité démarre automatique-
ment lors de la mise sous ten-
sion, sans avoir reçu aucun
signal de la télécommande.
Ces modèles sont équipés d’une fonction
de redémarrage automatique. Si vous
coupez l’alimentation principale sans
arrêter le climatiseur avec la télécom-
mande puis remettez sous tension, le
climatiseur démarre automatiquement
dans le même mode que celui qui avait
préalablement été sélectionné à l’aide de la
télécommande avant la mise hors tension.
Consultez la section “Fonction de redémar-
rage automatique” Page 5 .
L’unité interne se décolore
avec le temps.
Même si le plastique jaunit sous l’infl uence
de certains facteurs tels que le rayonnement
ultraviolet et la température, ceci n’a aucun
effet sur les fonctionnalités du produit.
Unité externe
Le ventilateur de l’unité ex-
terne ne tourne pas alors que
le compresseur fonctionne
correctement. Même s’il se
met à tourner, le ventilateur
s’arrête aussitôt.
Lorsque la température extérieure est basse,
le ventilateur fonctionne de façon inter-
mittente en mode de refroidissement pour
maintenir une capacité de refroidissement
suffi sante.
De l’eau s’écoule de l’unité
externe.
En mode de REFROIDISSEMENT et de
DESHUMIDIFICATION, la tuyauterie et les
raccords de tuyauterie sont refroidis et un
certain degré de condensation peut se pro-
duire.
Télécommande
Aucun affi chage sur la
télécommande ou affi chage
indistinct. L’unité interne ne
répond pas au signal de la
télécommande.
Les piles sont-elles déchargées ? Page 4
La polarité (+, -) des piles est-elle correcte ?
Page 4
Avez-vous appuyé sur les touches de télé-
commandes d’autres appareils électriques ?
Symptôme Explication & points à vérifi er
Le climatiseur ne refroidit pas correctement
Impossible de refroidir suffi -
samment la pièce.
Le réglage de la température est-il adapté ?
Page 5
Le réglage du ventilateur est-il adapté ?
Veuillez changer la vitesse du ventilateur à
Elevée ou Très élevée.
Page 6
Les fi ltres sont-il propres ? Page 8
Le ventilateur ou l’échangeur thermique de
l’unité interne sont-ils propres ?
L’entrée ou la sortie d’air des unités interne
et externe sont-elles obstruées ?
Y a t-il une fenêtre ou une porte ouvertes ?
Si vous utilisez un ventilateur ou une gaziniè-
re dans la pièce, la charge de refroidissement
augmente, et le refroidissement ne peut se
faire de manière satisfaisante.
Lorsque la température extérieure est élevée,
il se peut que le refroidissement ne se fasse
pas de manière satisfaisante.
Il est possible que l’unité prenne un certain
temps afin d’atteindre la température de
réglage, voire qu’elle ne l’atteigne pas en
fonction de la taille de la pièce, la température
ambiante, etc.
Flux d’air
L’air qui sort de l’unité in-
terne a une odeur étrange.
Les fi ltres sont-il propres ? Page 8
Le ventilateur ou l’échangeur thermique de
l’unité interne sont-ils propres ?
Le climatiseur peut être imprégné de l’odeur
d’un mur, d’un tapis, d’un meuble, de vête-
ments, etc. et la rejeter avec l’air pulsé.
Bruit
Des craquements se pro-
duisent.
Ce phénomène provient de l’expansion/la
contraction du panneau frontal, etc. en raison
des variations de température.
Un “murmure” est percep-
tible.
Ce bruit est perceptible lorsque de l’air frais
pénètre dans le tuyau d’écoulement ; il pro-
vient de l’évacuation de l’eau présente dans
le tuyau lors de l’ouverture du bouchon ou de
la rotation du ventilateur.
Ce bruit est également perceptible lorsque de
l’air frais pénètre dans le tuyau d’écoulement
par vents violents.
Un bruit mécanique provient
de l’unité interne.
Il s’agit du bruit de mise en marche/arrêt du
ventilateur ou du compresseur.
Un bruit d’écoulement d’eau
se produit.
Ce bruit peut provenir de la circulation du
réfrigérant ou de l’eau de condensation dans
le climatiseur.
Un siffl ement est parfois
perceptible.
Il s’agit du bruit que fait le réfrigérant à
l’intérieur du climatiseur lorsqu’il change de
sens.
Dans les cas suivants, arrêtez le climatiseur et consultez votre reven-
deur.
Si de l’eau s’écoule ou goutte de l’unité interne.
Si le témoin de fonctionnement supérieur clignote.
Si le disjoncteur saute régulièrement.
L’unité interne peut ne pas recevoir les signaux de la télécommande dans
une pièce dont le système d’éclairage est à lampes fl uorescentes (à oscilla-
teur intermittent, etc.).
Le fonctionnement du climatiseur interfère avec la réception radio ou TV.
Il peut s’avérer nécessaire de brancher un amplifi cateur sur l’appareil
concerné.
Si l’unité émet un bruit anormal.
Si du réfrigérant fuit.
EN PRESENCE D’UNE PANNE POTENTIELLE
Fr-10
FICHE TECHNIQUE
Gamme opérationnelle garantie
Interne Externe
Refroi-
disse-
ment
Limite
supérieure
90°F (32,2°C) DB 115°F (46,1°C) DB
73°F (22,8°C) WB
Limite
inférieure
67°F (19,4°C) DB 14°F (-10°C) DB
57°F (13,9°C) WB
DB : Bulbe sec
WB : Bulbe humide
Lieu d’installation
Evitez d’installer le climatiseur dans les endroits suivants.
En présence d’une grande quantité d’huile de machine.
Dans les régions où l’air est très salin, comme en bord de mer.
En présence de gaz sulfurés qui se dégagent par exemple des sources
chaudes ou des eaux usées.
Dans des endroits exposés à des projections d’huile ou dont l’atmosphère
est chargée d’huile (comme par exemple les cuisines et les usines en
raison du risque d’altération ou d’endommagement des propriétés des
matériaux plastiques).
En présence d’équipements haute fréquence ou sans fi l.
Dans un endroit où la sortie d’air de l’unité externe est susceptible d’être
obstruée.
Dans un endroit où le bruit de fonctionnement ou la pulsation d’air prove-
nant de l’unité externe représentent une nuisance pour le voisinage.
La hauteur de montage recommandée pour l’unité interne est de 5,9 ft. à
7,5 ft. (1,8 m à 2,3 m). Si cela n’est pas possible, consultez votre reven-
deur.
Travaux électriques
Veuillez prévoir un circuit réservé à l’alimentation du climatiseur.
Veuillez respecter la puissance électrique du disjoncteur.
Dans le doute, veuillez consulter votre revendeur.
LIEU D’INSTALLATION ET
TRAVAUX ELECTRIQUES
Eloignez le plus possi-
ble le climatiseur d’une
lampe uorescente pour
éviter tout parasitage.
mur, etc.
Lampes fl uorescentes à
oscillateur intermittent
Maintenez un
espace suffi sant
pour éviter
toute distorsion
de l’image ou
du son.
Radio
4 in. (100 mm)
minimum
Pour une effi cacité
maximale et une longévité
optimale, l’unité externe
doit être installée dans un
endroit sec et bien aéré.
8 in.
(200 mm)
minimum
TV
Télé-
phone
sans fi l ou
téléphone
portable
10 ft.
(3 m)
minimum
3 ft.
(1 m)
minimum
L’unité externe doit être installée à 10 ft. (3 m)
minimum des antennes de TV, radio, etc. Dans des
régions où la réception est faible, éloigner davantage
l’unité externe et l’antenne de l’appareil concerné si
le fonctionnement du climatiseur interfère avec la
réception radio ou TV.
1
Sélectionnez manuellement le mode de REFROIDIS-
SEMENT et réglez la température la plus élevée ;
faites fonctionner le climatiseur entre 3 et 4 heures.
Page 5
Cette opération permet de sécher l’intérieur du climatiseur.
La présence d'humidité dans la climatisation contribue à créer un
terrain favorable à la croissance de certains champignons tels que
la moisissure.
2
Appuyez sur
pour arrêter le fonctionnement du
climatiseur.
3
Débranchez la fi che d’alimentation électrique et/ou
coupez le disjoncteur.
4
Retirez toutes les piles de la télécommande.
Lorsque le climatiseur doit être remis en
service :
1
Nettoyez le fi ltre à air. Page 8
2
Veillez à ce que l’entrée et la sortie d’air des unités
interne et externe ne soient pas obstruées.
3
Veillez à raccorder correctement le câble de mise à la
terre.
4
Reportez-vous à la section “PREPARATIF D’UTILISA-
TION” et suivez les instructions. Page 4
SI LE CLIMATISEUR DOIT REST-
ER LONGTEMPS INUTILISE
3 ft.
(1 m)
minimum
Remarque:
1. Les valeurs de la gamme opérationnelle garantie sont valables pour le sys-
tème 1:1.
2. Si la température extérieure est en-dessous de la limite inférieure de la gam-
me opérationnelle garantie, il se peut que l’unité externe s’arrête jusqu’à ce
que la température extérieure dépasse la limite inférieure.
HEADOFFICE:TOKYOBLDG.,2-7-3,MARUNOUCHI,CHIYODA-KU,TOKYO100-8310,JAPAN
JG79Y023H01
01-JG79Y023H01_Cover.indd 2 7/31/2015 5:11:12 PM

Transcripción de documentos

SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSY-GL09NA MSY-GL15NA MSY-GL12NA For user OPERATING INSTRUCTIONS • To use this unit correctly and safely, be sure to read these operating instructions before use. English Para los clientes MANUAL DE INSTRUCCIONES • Para utilizar esta unidad de forma correcta y segura, lea previamente estas instrucciones de funcionamiento. Español A l’attention des clients NOTICE D’UTILISATION • Pour avoir la certitude d’utiliser cet appareil correctement et en toute sécurité, veuillez lire cette notice d’instructions avant de mettre le climatiseur sous tension. 01-JG79Y023H01_Cover.indd 1 Français 7/31/2015 5:11:12 PM ● OPERATING INSTRUCTIONS ● CONTENTS ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SAFETY PRECAUTIONS NAME OF EACH PART PREPARATION BEFORE OPERATION SELECTING OPERATION MODES FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT SMART SET OPERATION ECONO COOL OPERATION TIMER OPERATION (ON/OFF TIMER) CLEANING WHEN YOU THINK THAT TROUBLE HAS OCCURRED WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME INSTALLATION PLACE AND ELECTRICAL WORK SPECIFICATIONS 1 3 4 5 6 6 7 7 8 9 10 10 10 SAFETY PRECAUTIONS • Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read these “Safety Precautions” before use. • Since the cautionary items shown here are important for safety, be sure to observe them. • After reading this manual, keep it together with the installation manual in a handy place for easy reference. • Be sure to receive a guarantee card from your dealer and check that the purchased date and shop name, etc. are entered correctly. Marks and their meanings WARNING : Incorrect handling could cause serious hazard, such as death, serious injury, etc. with a high probability. CAUTION : Incorrect handling could cause serious hazard depending on the conditions. WARNING Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to a single AC outlet. • This may cause overheating, fire, or electric shock. Make sure the power plug is free of dirt and insert it securely into the outlet. • A dirty plug may cause fire or electric shock. Do not bundle, pull, or modify the power cord, and do not apply heat or place heavy objects on it. • This may cause fire or electric shock. Do not turn the breaker OFF/ON or disconnect/connect the power plug during operation. • This may create sparks, which can cause fire. • After the indoor unit is switched OFF with the remote controller, make sure to turn the breaker OFF or disconnect the power plug. Do not expose your body directly to cool air for a prolonged length of time. • This could be detrimental to your health. The unit should not be installed, relocated, disassembled, altered, or repaired by the user. • An improperly handled air conditioner may cause fire, electric shock, injury, or water leakage, etc. Consult your dealer. • If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order to avoid a hazard. When installing, relocating, or servicing the unit, make sure that no substance other than the specified refrigerant (R410A) enters the refrigerant circuit. • Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or injury. • The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction, or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety. Meanings of symbols used in this manual : Be sure not to do. : Be sure to follow the instruction. : Never insert your finger or stick, etc. : Never step onto the indoor/outdoor unit and do not put anything on them. : Danger of electric shock. Be careful. : Be sure to disconnect the power supply plug from the power outlet. : Be sure to shut off the power. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Do not insert your finger, a stick, or other objects into the air inlet or outlet. • This may cause injury, since the fan inside rotates at high speeds during operation. In case of an abnormal condition (such as a burning smell), stop the air conditioner and disconnect the power plug or turn the breaker OFF. • A continued operation in the abnormal state may cause a malfunction, fire, or electric shock. In this case, consult your dealer. When the air conditioner does not cool or heat, there is a possibility of refrigerant leakage. In this case, consult your dealer. If a repair involves recharging the unit with refrigerant, ask the service technician for details. • The refrigerant used in the air conditioner is safe. Normally, it does not leak. However, if refrigerant leaks and comes in contact with a heat source such as a fan heater, kerosene heater, or cooking stove, it will create a harmful gas. The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer. • Unsuitable detergent may cause damage to plastic material inside the unit, which may result in water leakage. Should detergent come in contact with electrical parts or the motor, it will result in a malfunction, smoke, or fire. En-1 02-JG79Y023H01_en.indd 1 7/31/2015 5:11:42 PM SAFETY PRECAUTIONS CAUTION Do not touch the air inlet or the aluminum fins of the indoor/outdoor unit. • This may cause injury. Do not use insecticides or flammable sprays on the unit. • This may cause a fire or deformation of the unit. Do not expose pets or houseplants to direct airflow. • This may cause injury to the pets or plants. Do not place other electric appliances or furniture under the indoor/outdoor unit. • Water may drip down from the unit, which may cause damage or malfunction. Do not leave the unit on a damaged installation stand. • The unit may fall and cause injury. Do not step on an unstable bench to operate or clean the unit. • This may cause injury if you fall down. Do not pull the power cord. • This may cause a portion of the core wire to break, which may cause overheating or fire. Do not charge or disassemble the batteries, and do not throw them into a fire. • This may cause the batteries to leak, or cause a fire or explosion. Do not operate the unit for more than 4 hours at high humidity (80% RH or more) and/or with windows or outside door left open. • This may cause the water condensation in the air conditioner, which may drip down, wetting or damaging the furniture. • The water condensation in the air conditioner may contribute to growth of fungi, such as mold. Do not use the unit for special purposes, such as storing food, raising animals, growing plants, or preserving precision devices or art objects. • This may cause deterioration of quality, or harm to animals and plants. Do not expose combustion appliances to direct airflow. • This may cause incomplete combustion. Never put batteries in your mouth for any reason to avoid accidental ingestion. • Battery ingestion may cause choking and/or poisoning. Before cleaning the unit, switch it OFF and disconnect the power plug or turn the breaker OFF. • This may cause injury, since the fan inside rotates at high speeds during operation. When the unit will be unused for a long time, disconnect the power plug or turn the breaker OFF. • The unit may accumulate dirt, which may cause overheating or fire. Replace all batteries of the remote controller with new ones of the same type. • Using an old battery together with a new one may cause overheating, leakage, or explosion. If the battery fluid comes in contact with your skin or clothes, wash them thoroughly with clean water. • If the battery fluid comes in contact with your eyes, wash them thoroughly with clean water and immediately seek medical attention. Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance. • Inadequate ventilation may cause oxygen starvation. Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike. • The unit may be damaged if lightning strikes. After the air conditioner is used for several seasons, perform inspection and maintenance in addition to normal cleaning. • Dirt or dust in the unit may create an unpleasant odor, contribute to growth of fungi, such as mold, or clog the drain passage, and cause water to leak from the indoor unit. Consult your dealer for inspection and maintenance, which require specialized knowledge and skills. Do not operate switches with wet hands. • This may cause electric shock. Do not clean the air conditioner with water or place an object that contains water, such as a flower vase, on it. • This may cause fire or electric shock. Do not step on or place any object on the outdoor unit. • This may cause injury if you or the object falls down. IMPORTANT Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold. It is therefore recommended to clean air filters every 2 weeks. For installation WARNING Consult your dealer for installing the air conditioner. • It should not be installed by the user since installation requires specialized knowledge and skills. An improperly installed air conditioner may cause water leakage, fire, or electric shock. Provide a dedicated power supply for the air conditioner. • A non-dedicated power supply may cause overheating or fire. Do not install the unit where flammable gas could leak. • If gas leaks and accumulates around the unit, it may cause an explosion. Ground the unit correctly. • Do not connect the ground wire to a gas pipe, water pipe, lightning rod, or a telephone ground wire. Improper grounding may cause electric shock. CAUTION Install a Ground Fault Interrupt (GFI) circuit breaker depending on the installation location of the air conditioner (such as highly humid areas). • If the Ground Fault Interrupt (GFI) breaker is not installed, it may cause electric shock. Ensure that the drain water is properly drained. • If the drain passage is improper, water may drip down from the indoor/outdoor unit, wetting and damaging the furniture. In case of an abnormal condition Immediately stop operating the air conditioner and consult your dealer. En-2 02-JG79Y023H01_en.indd 2 7/31/2015 5:11:42 PM ● OPERATING INSTRUCTIONS ● NAME OF EACH PART Indoor unit Remote controller Signal transmitting section Distance of signal : About 20 ft. (6 m) Front panel Air filter (Nano platinum filter) Operation display section Air cleaning filter (Anti-Allergy Enzyme Filter) Air inlet Beep(s) is (are) heard from the indoor unit when the signal is received. Battery replacement indicator Page 4 OFF/ON (stop/operate) button FAN speed control button Air outlet Horizontal vane Heat exchanger Display section Remote control receiving section Operation indicator lamp Emergency operation switch Page 5 Outdoor unit Temperature buttons Pages 4, 5 Page 6 Off-timer button Page 7 Operation select button On-timer button Page 7 Page 5 SMART SET button Page 6 ECONO COOL button Page 7 TIME set buttons Pages 4, 7 Increase time Decrease time VANE control button RESET button Page 4 Page 6 CLOCK button Page 4 Lid Slide down to open Remote controller holder Air inlet (back and side) Refrigerant piping Drainage hose Air outlet Drain outlet Outdoor units may be different in appearance. • Install the remote controller holder in a place where the signal can be received by the indoor unit. Only use the remote controller provided with the unit. Do not use other remote controllers. If two or more indoor units are installed in proximity to one another, an indoor unit that is not intended to be operated may respond to the remote controller. En-3 02-JG79Y023H01_en.indd 3 7/31/2015 5:11:43 PM PREPARATION BEFORE OPERATION Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on. Installing the remote controller batteries 4. 1. Press RESET. Remove the front lid. 2. 3. Insert the negative pole of AAA alkaline batteries first. Install the front lid. • Make sure the polarity of the batteries is correct. • Do not use manganese batteries and leaking batteries. The remote controller could malfunction. • Do not use rechargeable batteries. • The battery replacement indicator lights up when the battery is running low. In about 7 days after the indicator starts lights up, the remote controller stops working. • Replace all batteries with new ones of the same type. • Batteries can be used for approximately 1 year. However, batteries with expired shelf lives last shorter. • Press RESET gently using a thin instrument. If the RESET button is not pressed, the remote controller may not operate correctly. Setting current time 1. Press CLOCK. 2. 3. Press CLOCK again. Press the TIME buttons to set the time. Each press increases/decreases the time by 1 minute (10 minutes when pressed longer). • Press CLOCK gently using a thin instrument. Changing temperature units (°F→°C) Unit is preset with °F. 1. Press RESET while the temperature buttons are pressed. • Press RESET gently using a thin instrument. • To change temperature unit from °C to °F, press RESET. En-4 02-JG79Y023H01_en.indd 4 7/31/2015 5:11:43 PM ● OPERATING INSTRUCTIONS ● SELECTING OPERATION MODES I FEEL mode The unit selects the operation mode according to the room temperature when I FEEL is selected. When the room temperature is higher than 77°F (25°C), COOL is selected (set temperature: 75°F [24°C]). When the room temperature is lower than 77°F (25°C), DRY is selected. However, when operation is stopped and then started within 2 hours, the mode which has been selected previously is operated. Note: During COOL operation, the set temperature may not be changed when the room temperature is more than 4°F (2°C) higher than the set temperature. In this case, please wait until the room temperature drops to within 4°F (2°C) of the set temperature. COOL mode Enjoy cool air at your desired temperature. Note: Do not operate COOL mode at very low outside temperatures (less than 14°F [-10°C]). Water condensed in the unit may drip and wet or damage furniture, etc. DRY mode 1 2 to start the operation. Press FAN mode Circulate the air in your room. Press to select operation mode. Each press changes mode in the following order: (I FEEL ) 3 Dehumidify your room. The room may be cooled slightly. Temperature cannot be set during DRY mode. (COOL) (DRY) Emergency operation (FAN) When the remote controller cannot be used... Emergency operation can be activated by pressing the emergency operation switch (E.O.SW) on the indoor unit. Press or to set the temperature. Each press raises or lowers the temperature by 1°F (1°C). Each time the E.O.SW is pressed, the operation changes in the following order: Operation indicator lamp Press to stop the operation. • The same setting is selected the next time by simply pressing Operation indicator lamp The operation indicator lamp shows the operation state of the unit. Indication Operation state Room temperature About 4°F (2°C) or The unit is operating to reach the set more away from set temperature temperature . Emergency COOL Stop Set temperature : 75°F (24°C) Fan speed : Medium Horizontal vane : Auto Note: The first 30 minutes of operation is test run. Temperature control does not work, and fan speed is set to High. About 2 to 4°F (1 to The room temperature is approach2°C) from set teming the set temperature perature Lighted Not lighted Auto restart function If a power failure occurs or the main power is turned off during operation, “Auto restart function” automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power. When timer is set, timer setting is cancelled and the unit starts operation when power is resumed. If you do not want to use this function, please consult the service representative because the setting of the unit needs to be changed. En-5 02-JG79Y023H01_en.indd 5 7/31/2015 5:11:44 PM FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Press to select fan speed. Each press changes fan speed in the following order: (AUTO) (Quiet) (Low) (Med.) (High) (Super High) • Two short beeps are heard from the indoor unit when set to AUTO. • Use higher fan speed to cool the room quicker. It is recommended to lower the fan speed once the room is cool. • Use lower fan speed for quiet operation. Press to select airflow direction. Each press changes airflow direction in the following order: (AUTO) (1) (2) (3) (4) (5) (SWING) • Two short beeps are heard from the indoor unit when set to AUTO. Airflow direction (AUTO) .........The vane is set to the most efficient airflow direction. :horizontal position. (Manual) .......For efficient air conditioning, select the upper position for COOL/DRY, and the lower position for FAN. If the position (4) or (5) is selected during COOL/DRY, the vane automatically moves to the upward position after 0.5 to 1 hour to prevent any condensation from dripping. SMART SET OPERATION 1 2 Press during COOL or ECONO COOL mode to select SMART SET mode. Set the temperature, fan speed, and airflow direction. • The same setting is selected from the next time by simply pressing . • One setting can be saved. • Select the appropriate temperature, fan speed, and airflow direction according to your room. Press again to cancel SMART SET operation. • SMART SET operation also is cancelled when the MODE button is pressed. SMART SET operation A simplified set back function enables to recall the preferred (preset) setting with button. Press the button again and you can go back to a single push of the the previous setting in an instance. Example of use: 1. Low energy mode Set the temperature 4°F (2°C) to 6°F (3°C) warmer in COOL mode. This setting is suitable for unoccupied room, and while you are sleeping. 2. Saving frequently used settings Save your preferred setting for COOL/ECONO COOL. This enables you to select your preferred setting with a single push of the button. (Swing) .........The vane moves up and down intermittently. ■ To change the horizontal airflow direction. Move the vertical vane manually before starting operation. En-6 02-JG79Y023H01_en.indd 6 7/31/2015 5:11:45 PM ● OPERATING INSTRUCTIONS ● ECONO COOL OPERATION Press during COOL mode page 5 to start ECONO COOL operation. The unit performs swing operation vertically in various cycles according to the temperature of airflow. Set temperature is set 4°F (2°C) higher automatically. Press again to cancel ECONO COOL operation. • ECONO COOL operation is also cancelled when the VANE button is pressed. What is “ECONO COOL”? Swing airflow (change of airflow) makes you feel cooler than stationary airflow. So, even though the set temperature is automatically set at 4°F (2°C) higher, it is possible to perform cooling operation with keeping comfort. As a result, energy can be saved. TIMER OPERATION (ON/OFF TIMER) 1 Press or (ON timer) : during operation to set the timer. The unit turns ON at the set time. (OFF timer) : The unit turns OFF at the set time. * or blinks. * Make sure that the current time is set correctly. Page 4 2 Press (Increase) and time of timer. (Decrease) to set the Each press increases or decreases the set time by 10 minutes. or is blinking. • Set the timer while 3 Press or again to cancel timer. Note: • ON and OFF timers can be set together. mark indicates the order of timer operations. • If power failure occurs while ON/OFF timer is set, see page 5 “Auto restart function”. En-7 02-JG79Y023H01_en.indd 7 7/31/2015 5:11:46 PM CLEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Be careful not to touch the metal parts with your hands. • Do not use benzine, thinner, polishing powder, or insecticide. • Use only diluted mild detergents. • Do not expose parts to direct sunlight, heat, or fire to dry. • Do not use water hotter than 120°F (50°C). Air cleaning filter (Anti-Allergy Enzyme Filter) Air filter (Nano platinum filter) • Clean every 2 weeks • Remove dirt by a vacuum cleaner, or rinse with water. • After washing with water, dry it well in shade. What is “Nano platinum filter”? Nano platinum is a ceramic particle that includes a platinum nanoparticle. The particles are incorporated into the filter material, which results in providing semi-permanent antibacterial and deodorizing characteristics for the filter. Nano platinum surpasses the catechin (a bioflavonoid that is found in green tea) in performance. Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses. This air filter has a semi-permanent lasting effect even after washing it with water. Back side of air filter Every 3 months: • Remove dirt by a vacuum cleaner. When dirt cannot be removed by vacuum cleaning: • Soak the filter and its frame in lukewarm water before rinsing it. • After washing, dry it well in shade. Every year: • Replace it with a new air cleaning filter for best performance. • Parts Number MAC-408FT-E Pull to remove from the air filter Front panel Important Hinge Hole 1. Lift the front panel until a “click” is heard. • Clean the filters regularly for best performance and to reduce power consumption. • Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold. It is therefore recommended to clean air filters every 2 weeks. 2. Hold the hinges and pull to remove as shown in the illustration above. • Wipe with a soft dry cloth or rinse it with water. • Do not soak it in water for more than two hours. • Dry it well in shade. 3. Install the front panel by following the removal procedure in reverse. Close the front panel securely and press the positions indicated by the arrows. En-8 02-JG79Y023H01_en.indd 8 7/31/2015 5:11:46 PM ● OPERATING INSTRUCTIONS ● WHEN YOU THINK THAT TROUBLE HAS OCCURRED Even if these items are checked, when the unit does not recover from the trouble, stop using the air conditioner and consult your dealer. Symptom Explanation & Check points Symptom The room cannot be cooled sufficiently. Indoor Unit The unit cannot be operated. • Is the breaker turned on? • Is the power supply plug connected? • Is the ON timer set? Page 7 The horizontal vane does not move. • Are the horizontal vanes installed correctly? • Is the fan guard deformed? The unit cannot be operated for about 3 minutes when restarted. • This protects the unit according to instructions from the microprocessor. Please wait. Mist is discharged from the air • The cool air from the unit rapidly cools moisoutlet of the indoor unit. ture in the air inside the room, and it turns into mist. The swing operation of the HORIZONTAL VANE is suspended for a while, then restarted. • This is for the swing operation of the HORIZONTAL VANE to be performed normally. The airflow direction changes during operation. The direction of the horizontal vane cannot be adjusted with the remote controller. • When the unit is operated in COOL or DRY mode, if the operation continues with air blowing down for 0.5 to 1 hour, the direction of the air flow is automatically set to upward position to prevent water from condensing and dripping. The unit starts operation by • These models are equipped with an auto reitself when the main power is start function. When the main power is turned turned on, but hasn’t received off without stopping the unit with the remote sign from the remote controlcontroller and is turned on again, the unit ler. starts operation automatically in the same mode as the one set with the remote controller just before the shutoff of the main power. Refer to “Auto restart function” page 5 . The indoor unit discolors over time. • When the outside temperature is low during The fan of the outdoor unit cooling operation, the fan operates intermitdoes not rotate even though tently to maintain sufficient cooling capacity. the compressor is running. Even if the fan starts to rotate, it stops soon. Water leaks from the outdoor unit. • During COOL and DRY operations, pipe or pipe connecting sections are cooled and this causes water to condense. Remote controller The display on the remote controller does not appear or it is dim. The indoor unit does not respond to the remote control signal. • Are the batteries exhausted? Page 4 • Is the polarity (+, -) of the batteries correct? Page 4 • Are any buttons on the remote controller of other electric appliances being pressed? • Is the temperature setting appropriate? Page 5 • Is the fan setting appropriate? Please change fan speed to High or Super High. Page 6 • Are the filters clean? Page 8 • Is the fan or heat exchanger of the indoor unit clean? • Are there any obstacles blocking the air inlet or outlet of the indoor or outdoor unit? • Is a window or door open? • When a ventilation fan or a gas cooker is used in a room, the cooling load increases, resulting in an insufficient cooling effect. • When the outside temperature is high, the cooling effect may not be sufficient. • It may take a certain time to reach the setting temperature or may not reach that depending on the size of the room, the ambient temperature, and the like. Airflow The air from the indoor unit smells strange. • Are the filters clean? Page 8 • Is the fan or heat exchanger of the indoor unit clean? • The unit may suck in an odor adhering to the wall, carpet, furniture, cloth, etc. and blow it out with the air. Sound Cracking sound is heard. • This sound is generated by the expansion/ contraction of the front panel, etc. due to change in temperature. “Burbling” sound is heard. • This sound is heard when the outside air is absorbed from the drain hose by turning on the range hood or the ventilation fan, making water flowing in the drain hose to spout out. This sound is also heard when the outside air blows into the drain hose in case the outside wind is strong. Mechanical sound is heard from the indoor unit. • This is the switching sound in turning on/off the fan or the compressor. The sound of water flowing is heard. • This is the sound of refrigerant or condensed water flowing in the unit. Hissing sound is sometimes heard. • This is the sound when the flow of refrigerant inside the unit is changed. • Although plastic turns yellow due to the influence of some factors such as ultraviolet light and temperature, this has no effect on the product functions. Outdoor Unit Explanation & Check points Does not cool In the following cases, stop using the air conditioner and consult your dealer. • When water leaks or drips from the indoor unit. • When the upper operation indicator lamp blinks. • When the breaker trips frequently. • The remote control signal is not received in a room where an electronic ON/OFF type fluorescent lamp (inverter-type fluorescent lamp, etc.) is used. • Operation of the air conditioner interferes with radio or TV reception. An amplifier may be required for the affected device. • When an abnormal sound is heard. • When any refrigerant leakage is found. En-9 02-JG79Y023H01_en.indd 9 7/31/2015 5:11:46 PM WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 1 Set to the highest temperature in manual COOL mode, and operate for 3 to 4 hours. Page 5 • This dries the inside of the unit. • Moisture in the air conditioner contributes to favorable conditions for growth of fungi, such as mold. 2 3 4 Press to stop the operation. Turn off the breaker and/or disconnect the power supply plug. 2 3 4 ELECTRICAL WORK Installation place Avoid installing the air conditioner in the following places. • Where there is much machine oil. • Salty places such as the seaside. • Where sulfide gas is generated such as hot spring, sewage, waste water. • Where oil is splashed or where the area is filled with oily smoke (such as cooking areas and factories, in which the properties of plastic could be changed and damaged). • Where there is high-frequency or wireless equipment. • Where the air from the outdoor unit air outlet is blocked. • Where the operation sound or air from the outdoor unit bothers the house next door. • The mounting height of indoor unit 5.9 ft. to 7.5 ft. (1.8 m to 2.3 m) is recommended. If it is impossible, please consult your dealer. The installation location of the outdoor unit should be at least 10 ft. (3 m) away from the antennas for TV sets, radios, etc. In areas where the reception is weak, provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception. Remove all batteries from the remote controller. When using the air conditioner again: 1 INSTALLATION PLACE AND To prevent the effects of a fluorescent lamp, keep as far apart as possible. Inverter-type fluorescent lamp Clean the air filter. Page 8 Check that the air inlet and outlet of the indoor and outdoor units are not blocked. Check that the ground wire is connected correctly. Refer to the “PREPARATION BEFORE OPERATION”, and follow the instructions. Page 4 Keep a space to prevent the picture distortion or the noise. 3 ft. (1 m) or more Cordless phone or Portable phone 3 ft. (1 m) or more Radio For the optimum efficiency and to extend the life time of using, the outdoor unit should be installed in a well-ventilated dry place. wall, etc. 4 in. (100 mm) or more 8 in. (200 mm) or more) TV 10 ft. (3 m) or more Electrical work • Provide an exclusive circuit for the power supply of the air conditioner. • Be sure to observe the breaker capacity. If you have any questions, consult your dealer. SPECIFICATIONS Guaranteed operating range Indoor Outdoor 90°F (32.2°C) DB 115°F (46.1°C) DB 73°F (22.8°C) WB — Cooling 67°F (19.4°C) DB 14°F (-10°C) DB Lower limit 57°F (13.9°C) WB — DB : Dry Bulb WB : Wet Bulb Upper limit Note: 1. The guaranteed operating range value is for 1:1 System Application. 2. If the outdoor temperature is below the lower limit of guaranteed operating range, the outdoor unit may stop operation until the outdoor temperature exceeds the lower limit. En-10 02-JG79Y023H01_en.indd 10 7/31/2015 5:11:47 PM ● MANUAL DE INSTRUCCIONES ● ÍNDICE ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ MEDIDAS DE SEGURIDAD NOMBRE DE LAS PARTES PREPARACIÓN ANTES DE LA PUESTA EN MARCHA SELECCIÓN DE MODOS DE FUNCIONAMIENTO VELOCIDAD DEL VENTILADOR Y AJUSTE DE LA DIRECCIÓN DEL AIRE FUNCIONAMIENTO SMART SET (SELECCIÓN INTELIGENTE) FUNCIONAMIENTO DE LA DESCONEXIÓN AUTOMÁTICA (ECONO COOL) FUNCIONAMIENTO DEL TEMPORIZADOR (ACTIVACIÓN/DESACTIVACIÓN DEL TEMPORIZADOR) LIMPIEZA SI CREE QUE HA OCURRIDO ALGÚN PROBLEMA CUANDO EL ACONDICIONADOR DE AIRE NO SE VAYA A UTILIZAR DURANTE MUCHO TIEMPO LUGAR DE INSTALACIÓN Y TRABAJO ELÉCTRICO ESPECIFICACIONES 1 3 4 5 6 6 7 7 8 9 10 10 10 MEDIDAS DE SEGURIDAD • Puesto que este producto tiene piezas rotatorias y piezas que pueden provocar descargas eléctricas, lea atentamente las “Medidas de seguridad” antes de usarlo. Símbolos utilizados en este manual y su significado : Asegúrese de no hacerlo. • Tome las precauciones aconsejadas en este manual, ya que son importantes para una utilización segura del producto. : Siga las instrucciones estrictamente. • Después de leer este manual, guárdelo a mano junto con el manual de instalación para poder recurrir a él con facilidad. : No introduzca nunca los dedos ni objetos, etc. • Asegúrese de recibir la garantía de su distribuidor y comprobar que contiene la fecha de compra, el nombre del establecimiento, etc. correctos. : No se suba a la unidad interior/exterior ni ponga nada encima. Indicaciones y sus significados ATENCIÓN: Una manipulación incorrecta podría conllevar con toda probabilidad un peligro grave, por ejemplo, de muerte o de heridas graves. CUIDADO: Una manipulación incorrecta podría conllevar, según las condiciones, un peligro grave. ATENCIÓN No conecte el cable de alimentación a un punto intermedio; utilice una alargadera o conecte varios dispositivos a una sola toma de CA. • Podría causar sobrecalentamiento, fuego o descarga eléctrica. Asegúrese que el enchufe no tiene polvo e insértelo de forma segura en la toma de corriente. • Si el enchufe está sucio puede provocar fuego o una descarga eléctrica. No enrolle ni cambie ni tire del cable de alimentación, y no aplique calor ni coloque objetos pesados sobre el mismo. • Podría causar fuego o una descarga eléctrica. No accione el disyuntor OFF/ON ni desconecte/conecte el enchufe de alimentación durante el funcionamiento. • Podría generar chispas y originar un fuego. • Una vez que la se apaga la unidad interior con el controlador remoto, asegúrese de que coloca el disyuntor en OFF o que desconecta el enchufe de alimentación. Evite la exposición directa de la piel al aire frío durante un periodo de tiempo prolongado. • Puede ser perjudicial para la salud. El usuario no debe instalar, cambiar de sitio, desmontar, alterar ni reparar la unidad. • Si no se maneja correctamente, el acondicionador de aire puede causar fuego, descarga eléctrica, lesiones, escape de agua, etc. Consulte con su distribuidor. • Si el cable de alimentación está dañado, deberá ser sustituido por el fabricante o su agente de mantenimiento para evitar cualquier riesgo. Al instalar, reubicar o reparar la unidad, asegúrese de que en el circuito de refrigeración no entra ninguna otra sustancia que no sea el refrigerante especificado (R410A). • La presencia de cualquier otra sustancia extraña, como aire por ejemplo, puede provocar una elevación anómala de la presión, una explosión o daños corporales. • El uso de un refrigerante distinto al especificado por el sistema ocasionará fallos mecánicos, malfuncionamiento del sistema o averías en la unidad. En el peor de los casos, esto podría llegar a ser un serio impedimento para garantizar el uso seguro del producto. : Peligro de descarga eléctrica. Tenga cuidado. : Asegúrese de desconectar el enchufe de alimentación de la toma de corriente. : Asegúrese de desconectar la corriente. Este aparato no debe ser utilizado por personas (incluidos niños) que presenten una discapacidad física, sensorial o mental así como aquellos que dispongan de la experiencia o el conocimiento, a menos que lo hagan bajo la supervisión o instrucción relativa al uso del aparato por una persona responsable de su seguridad. Se debe supervisar a los niños para garantizar que no jueguen con el aparato. No introduzca los dedos, palos, etc. en las entradas/salidas de aire. • Podría causar daños, puesto que el ventilador del interior gira a alta velocidad durante el funcionamiento. En caso de que se produzca una condición anómala (como olor a quemado), pare el aparato y desconecte el enchufe de alimentación o coloque el disyuntor en OFF. • Si se prolonga el funcionamiento en la condición anómala puede producirse un fallo, fuego o una descarga eléctrica. En tal caso, consulte a su distribuidor. Cuando el acondicionador de aire no enfría o no calienta, es posible que haya una fuga del refrigerante. En tal caso, consulte a su distribuidor. Si una reparación exige la recarga de la unidad con refrigerante, solicite más información al técnico de servicio. • El refrigerante que se usa en el acondicionador de aire es seguro. Normalmente no tiene fugas. Ahora bien, si hay fuga de refrigerante y éste entra en contacto con una fuente de calor como un calentador de ventilador, un calentador de parafina o un horno de cocina, generará gases perjudiciales. El usuario nunca debería intentar lavar el interior de la unidad interior. Si el interior de la unidad requiere limpieza, póngase en contacto con el distribuidor. • Un detergente inadecuado puede provocar daños a los materiales plásticos del interior de la unidad, lo que puede tener como consecuencia pérdidas de agua. Si el detergente entra en contacto con las partes eléctricas del motor, provocará mal funcionamiento, humo o fuego. Sp-1 JG79Y023H01_es.indd 1 7/30/2015 3:51:12 PM MEDIDAS DE SEGURIDAD CUIDADO No utilice los mandos con las manos mojadas. • Podría producirse una descarga eléctrica. No toque la entrada de aire ni la aleta de aluminio de la unidad interior/exterior. • Podría hacerse daño. No limpie el acondicionador de aire con agua ni coloque sobre él un objeto que contenga agua, como un florero. • Podría causar fuego o una descarga eléctrica. No eche insecticidas ni pulverizadores inflamables sobre la unidad. • Podrían provocar incendios o deformaciones de la unidad. No se suba a la unidad exterior ni coloque ningún objeto encima. • Si se cayera usted o el objeto, podría haber daños. Evite la exposición directa de animales domésticos o plantas al flujo de aire. • Puede causar daños a los animales y las plantas. No coloque otros electrodomésticos o muebles debajo de la unidad interior/exterior. • Podría gotear agua desde la unidad, que podría causar daños o hacer que funcionara mal. No instale la unidad en un soporte roto. • La unidad podría caer y causar daños. IMPORTANTE Los filtros sucios pueden provocar condensación en el acondicionador de aire que contribuye a la formación de hongos, como el moho. Por lo tanto, es recomendable limpiar los filtros cada 2 semanas. Mientras limpia o hace funcionar la unidad, no tenga los pies en una superficie inestable. • Si se cayera, podría hacerse daño. No tire del cable de alimentación. • Podría hacer que se rompa parte del núcleo del cable, lo que puede causar sobrecalentamiento o fuego. No cargue ni desarme las pilas y no las arroje al fuego. • Podría provocar fugas en las pilas, o causar fuego o una explosión. La unidad no debe estar en funcionamiento más de 4 horas en condiciones de humedad elevada (80% de humedad relativa o superior) y/o con la puerta de entrada o las ventanas abiertas. • Esto podría causar un descenso en la condensación de agua en el acondicionador de aire que podría humedecer o dañar el mobiliario. • La condensación de agua en el acondicionador de aire podría contribuir a la formación de hongos, como el moho. No use la unidad para fines especiales, como para almacenar alimentos, criar animales, cultivar plantas o guardar dispositivos de precisión u objetos de arte. • Podría deteriorar la calidad o causar daños a los animales y plantas. Evite la exposición directa de aparatos de combustión al flujo de aire. • Podría interrumpir la combustión. Para evitar una ingestión accidental, no coloque las pilas en su boca bajo ningún concepto. • La ingestión de las pilas puede causar asfixia y/o envenenamiento. Antes de limpiar la unidad, apáguela y desconecte el cable de alimentación o coloque el disyuntor en OFF. • Podría causar daños, puesto que el ventilador del interior gira a alta velocidad durante el funcionamiento. Si la unidad va a dejar de usarse un tiempo prolongado, desconecte el cable de alimentación o coloque el disyuntor en OFF. • La unidad puede acumular polvo y provocar sobrecalentamiento o fuego. Sustituya las pilas del controlador remoto por otras nuevas de la misma clase. • La utilización de una pila usada junto con una nueva puede causar sobrecalentamiento, provocar una fuga o producir una explosión. Para la instalación ATENCIÓN Pida a su distribuidor que instale el aire acondicionado. • No debe instalarlo el usuario, puesto que requiere conocimientos y capacidades especializadas. Si no se instala correctamente, puede provocar fugas, fuego o descargas eléctricas. Dedique una toma de alimentación en exclusiva al acondicionador de aire. • Si no se utiliza una toma de alimentación en exclusiva, pueden producirse sobrecalentamiento o fuego. No instale la unidad donde pueda haber fugas de gas inflamable. • Si hay una fuga de gas y éste se acumula cerca de la unidad, podría producirse una explosión. Conecte la unidad a una toma a tierra. • No conecte el cable de tierra a una tubería de gas, tubería de agua, pararrayos o cable de tierra de un teléfono. Si no, podría producirse una descarga eléctrica. CUIDADO Instale un disyuntor de pérdidas de tierra en función del lugar de instalación del aire acondicionado (por ejemplo, áreas muy húmedas). • Si no instala el disyuntor de pérdidas de tierra, podrían producirse descargas eléctricas. Asegúrese de que se drena correctamente el agua de drenaje. • Si el conducto de drenaje no es correcto, el agua podría caer desde la unidad interior/exterior, causando humedad y daños en el mobiliario. Si se produce una condición anómala Pare de inmediato el acondicionador de aire y consulte a su distribuidor. Si el líquido de la pila entra en contacto con la piel o la ropa, lávelas a fondo con agua limpia. • Si el líquido de la pila entra en contacto con los ojos, lávelos a fondo con agua limpia y acuda a un médico de inmediato. Asegúrese de que la zona está bien ventilada cuando la unidad esté en funcionamiento junto con un aparato de combustión. • Una ventilación inadecuada puede originar falta de oxígeno. Coloque el disyuntor en OFF si oye truenos y hay posibilidad de que caigan rayos. • La unidad puede resultar dañada si cae algún rayo. Tras varias estaciones con el acondicionador de aire en funcionamiento, efectúe una inspección y el mantenimiento además de la limpieza habitual. • Si hay polvo o suciedad en la unidad se puede producir un olor desagradable, contribuir al crecimiento de hongos, como el moho, o bien bloquear el conducto de drenaje, lo que hace que gotee agua de la unidad interior. Consulte con su distribuidor sobre la inspección y el mantenimiento, puesto que exigen conocimientos y capacidades especializadas. Sp-2 JG79Y023H01_es.indd 2 7/30/2015 3:51:12 PM ● MANUAL DE INSTRUCCIONES ● NOMBRE DE LAS PARTES Unidad interior Controlador remoto Sección de transmisión de señales Distancia de la señal: Aprox. 20 pies (6 m) Panel frontal Sección de pantalla de accionamiento Filtro de aire (filtro de nanoplatino) Indicador de sustitución de las pilas Página 4 Filtro de limpieza de aire (Filtro de enzimas antialérgico) Entrada de aire Botón OFF/ON (desactivación/ activación de funcionamiento) Botón de control de velocidad del ventilador Página 6 Salida de aire Deflector horizontal Cuando se recibe la señal, la unidad interior emite un sonido. Intercambiador de calor Sección de pantalla Sección de recepción del controlador remoto Luz de indicación del funcionamiento Interruptor de accionamiento de emergencia Página 5 Unidad exterior Botón de selección del modo de funcionamiento Página 5 Botón de desconexión automática (ECONO COOL) Página 7 Botón de control de las lamas Página 6 Botones de temperatura Páginas 4, 5 Botón de desactivación del temporizador Página 7 Botón de activación del temporizador Página 7 Botón SMART SET (SELECCIÓN INTELIGENTE) Página 6 Botones de ajuste del TIMER (TEMPORIZADOR) Páginas 4, 7 Aumentar tiempo Reducir tiempo Botón de ajuste del reloj (CLOCK) Página 4 Botón de reinicialización (RESET) Página 4 Tapa Deslícela hacia abajo para abrir Soporte del controlador remoto Entrada de aire (lado posterior y lateral) Tubería de refrigerante Manguera de drenaje Salida de aire Salida de drenaje La apariencia de las unidades exteriores puede ser diferente. • Instale el soporte del controlador remoto en un lugar en el que la unidad interior pueda recibir la señal. Use únicamente el controlador remoto suministrado con la unidad. No use otro controlador remoto. Si dos o más unidades interiores están instaladas cerca unas de otras, puede que la unidad que no se pretendía activar, responda al controlador remoto. Sp-3 JG79Y023H01_es.indd 3 7/30/2015 3:51:13 PM PREPARACIÓN ANTES DE LA PUESTA EN MARCHA Antes de la puesta en marcha: inserte el enchufe de alimentación en la toma de corriente y/o encienda el disyuntor. Instalación de las pilas del controlador remoto 4. 1. Pulse RESET. Retire la tapa frontal. 2. 3. Inserte primero el polo negativo de las pilas alcalinas tipo AAA. Coloque la tapa frontal. • Asegúrese de que la polaridad de las pilas es la correcta. • No utilice pilas de manganeso o pilas con fugas. El controlador remoto podría funcionar inadecuadamente. • No utilice pilas recargables. • El indicador de sustitución de las pilas se ilumina cuando las pilas tienen poca carga. El controlador remoto dejará de funcionar al cabo de aproximadamente 7 días desde que el indicador se ilumina por primera vez. • Sustituya todas las pilas por otras nuevas de la misma clase. • Las pilas pueden durar 1 año aproximadamente. Ahora bien, las pilas caducadas pueden durar menos. • Pulse RESET (reiniciar) suavemente utilizando un objeto en punta. Si no se pulsa el botón de reinicialización (RESET), el controlador remoto no funcionará correctamente. Ajuste de la hora actual 1. 3. Pulse CLOCK (temporizador). 2. Pulse otra vez CLOCK (temporizador). Pulse los botones de TIME para ajustar la hora. Cada pulsación aumenta/disminuye la hora en 1 minuto (10 minutos cuando la pulsación es prolongada). • Pulse CLOCK (temporizador) suavemente utilizando un objeto en punta. Cambio de unidades de temperatura (˚F→˚C) La unidad esta configurada por defecto con °F. 1. Pulse RESET (reiniciar) con los botones de temperatura pulsados. • Pulse RESET (reiniciar) suavemente utilizando un objeto en punta. • Para cambiar la unidad de temperatura de °C a °F, pulse RESET. Sp-4 JG79Y023H01_es.indd 4 7/30/2015 3:51:13 PM ● MANUAL DE INSTRUCCIONES ● SELECCIÓN DE MODOS DE FUNCIONAMIENTO Modo I FEEL La unidad selecciona el modo de funcionamiento en función de la temperatura ambiente cuando I FEEL está seleccionado. Cuando la temperatura ambiente es superior a 77°F (25°C), se selecciona REFRIGERACIÓN (temperatura establecida: 75°F [24°C]). Cuando la temperatura ambiente es inferior a 77 ºF (25ºC), se selecciona DESHUMIDIFICACIÓN. Sin embargo, cuando la unidad deja de funcionar y vuelve a ponerse en marcha antes de 2 horas, se activa el modo que estaba seleccionado previamente. Nota: Mientras funciona en el modo REFRIGERACIÓN, es posible que no se cambie la temperatura establecida si la temperatura ambiente la supera en más de 4ºF (2ºC). En este caso, espere hasta que la temperatura ambiente descienda hasta 4ºF (2ºC) por debajo de la temperatura establecida. Modo de REFRIGERACIÓN Disfrute de aire frío a la temperatura que desee. Nota: No ponga en funcionamiento el modo de REFRIGERACIÓN con temperaturas muy bajas en el exterior (inferior a 14°F [-10°C]). El agua condensada en la unidad puede gotear y humedecer o dañar el mobiliario, etc. Modo de DESHUMIDIFICACIÓN 1 2 Deshumedezca su habitación. Puede refrigerarla ligeramente. La temperatura no se puede ajustar mientras el aparato está en el modo de DESHUMIDIFICACIÓN. Pulse para que se ponga en funcionamiento. Pulse para seleccionar el modo de funcionamiento. El modo cambia con cada pulsación de la manera siguiente: (I FEEL) (REFRIGERACIÓN) (DESHUMIDIFICACIÓN) (VENTILADOR) 3 Modo de VENTILADOR Haga circular el aire en la habitación. Pulse o para ajustar la temperatura. Cada pulsación eleva o disminuye la temperatura en 1°F (1°C). Funcionamiento de emergencia Si no se puede utilizar el controlador remoto... Se puede activar el funcionamiento de emergencia pulsando el interruptor de accionamiento de emergencia (E.O.SW) en la unidad interior. Cada vez que se pulsa el interruptor de accionamiento de emergencia (E.O.SW), el funcionamiento cambia en el orden siguiente: Luz de indicación de funcionamiento REFRIGERACIÓN de emergencia Pulse para apagarlo. • Cuando vuelva a encenderlo, se activará la misma configuración seleccionada si pulsa . Luz de indicación de funcionamiento La luz de indicación de funcionamiento muestra el estado de funcionamiento de la unidad. Indicación Estado de funcionamiento Aproximadamente de 2 a La temperatura ambiente se acerca 4°F (1 a 2°C) de diferena la temperatura fijada cia con la temperatura fijada Luz apagada Temperatura fijada: 75°F (24°C) Velocidad del ventilador: media Deflector horizontal: auto Nota: Los primeros 30 minutos de funcionamiento son de prueba. El control de temperatura no funciona y la velocidad del ventilador está fijada en “Alta”. Temperatura ambiente Aproximadamente 4°F La unidad está en funcionamiento (2°C) o más de diferencia para alcanzar la temperatura fijada con la temperatura fijada Luz encendida Parada Función de reinicio automático En caso de que se produzca un corte en el suministro eléctrico o se apague la unidad mientras esté funcionando, la “Función de reinicio automático” se activará automáticamente en el mismo modo seleccionado con el controlador remoto antes de que se interrumpiese el funcionamiento. Cuando está configurado el temporizador, los ajustes se anulan y la unidad empieza a funcionar al volver a encenderla. Si no desea utilizar esta función, póngase en contacto con el servicio técnico ya que tendrá que modificar los ajustes de la unidad. Sp-5 JG79Y023H01_es.indd 5 7/30/2015 3:51:16 PM VELOCIDAD DEL VENTILADOR Y AJUSTE DE LA DIRECCIÓN DEL AIRE Pulse para seleccionar la velocidad del ventilador. La velocidad del ventilador cambia con cada pulsación en el orden siguiente: (AUTO) (Quiet [Silencioso]) (Baja) (Media) (Alta) (Muy alta) • Al configurar la unidad interior en AUTO, se escuchan dos pitidos cortos. • Utilice una velocidad de ventilador superior para enfriar la habitación más rápidamente. Se recomienda reducir la velocidad del ventilador una vez que la habitación se ha enfriado. • Utilice una velocidad de ventilador inferior para un funcionamiento silencioso. Pulse para seleccionar la dirección del aire. La dirección del aire cambia con cada pulsación en el orden siguiente: (AUTO) (1) (2) (3) (4) (5) (OSCILACIÓN) • Al configurar la unidad interior en AUTO, se escuchan dos pitidos cortos. Dirección del flujo de aire (AUTO).............El deflector se ajusta en la dirección de flujo de aire que ofrece un mayor rendimiento. : posición horizontal. (Manual) ...........Para un mejor rendimiento del acondicionador de aire, seleccione la posición superior para REFRIGERACIÓN/ DESHUMIDIFICACIÓN y la posición inferior para VENTILADOR. Si se selecciona la posición (4) o (5) durante el modo de REFRIGERACIÓN/DESHUMIDIFICACIÓN, el deflector se desplaza automáticamente a la posición hacia arriba pasado un período de 30 minutos a 1 hora para evitar que gotee el agua de condensación. (Oscilación) ......El deflector se desplaza hacia arriba y hacia abajo de forma intermitente. FUNCIONAMIENTO SMART SET (SELECCIÓN INTELIGENTE) 1 2 Pulse durante el modo de REFRIGERACIÓN o DESCONEXIÓN AUTOMÁTICA (ECONO COOL) para seleccionar el modo de SMART SET (SELECCIÓN INTELIGENTE). Establezca la temperatura, la velocidad del ventilador y la dirección del flujo de aire. • La próxima vez que lo encienda, podrá seleccionar esta misma confi. guración sólo con pulsar • Se puede guardar una configuración. • Seleccione la temperatura, la velocidad del ventilador y la dirección del flujo de aire adecuadas para la habitación. Vuelva a pulsar para cancelar el funcionamiento SMART SET (SELECCIÓN INTELIGENTE). • El funcionamiento SMART SET (SELECCIÓN INTELIGENTE) también se cancela al pulsar el botón MODE (MODO). Funcionamiento SMART SET (SELECCIÓN INTELIGENTE) Mediante una sencilla función de selección previa se puede recordar la confi. Para volver a guración preferida (preestablecida) con sólo pulsar el botón la configuración anterior, vuelva a pulsar el botón. Ejemplo de uso: 1. Modo de bajo consumo Aumente la temperatura de 4°F (2°C) a 6°F (3°C) en modo de REFRIGERACIÓN. Puede usar esta configuración para una habitación desocupada o mientras duerme. 2. Guardar las configuraciones más frecuentes Guarde sus configuraciones preferidas para los modos de REFRIGERACIÓN/DESCONEXIÓN AUTOMÁTICA (ECONO COOL). De esta forma, podrá seleccionar su configuración preferida con solo pulsar un botón. ■ Para cambiar la dirección del flujo de aire. Desplace el deflector vertical manual antes de que empiece a funcionar el acondicionador. Sp-6 JG79Y023H01_es.indd 6 7/30/2015 3:51:17 PM ● MANUAL DE INSTRUCCIONES ● FUNCIONAMIENTO DE LA DESCON- EXIÓN AUTOMÁTICA (ECONO COOL) FUNCIONAMIENTO DEL TEMPORIZADOR (ACTI- VACIÓN/DESACTIVACIÓN DEL TEMPORIZADOR) 1 Pulse o durante el funcionamiento para ajustar el temporizador. (ACTIVACIÓN del temporizador): La unidad se encenderá a la hora establecida. (DESACTIVACIÓN del temporizador): La unidad se apagará a la hora establecida. * o parpadea. * Asegúrese de que la hora actual es la correcta. Página 4 2 Pulse (Aumentar) y la hora del temporizador. (Disminuir) para ajustar Con cada pulsación la hora establecida aumenta o disminuye en 10 minutos. o parpadean. • Ajuste el temporizador mientras 3 Pulse durante el modo de REFRIGERACIÓN Página 5 para iniciar el funcionamiento de desconexión automática (ECONO COOL). La unidad realiza la operación de oscilación verticalmente en varios ciclos según la temperatura del flujo de aire. La temperatura fijada sube automáticamente 4°F (2°C). Pulse rizador. o de nuevo para cancelar el tempo- Nota: • Los temporizadores de ON (encendido) y OFF (apagado) se pueden configurar a la vez. La marca “ ” muestra el orden en el que se activarán los temporizadores. • Si se produce un corte en el suministro eléctrico mientras está configurado el temporizador en ACTIVACIÓN/DESACTIVACIÓN, consulte la Página 5 “Función de reinicio automático”. Pulse otra vez para cancelar la operación ECONO COOL. • El funcionamiento de DESCONEXIÓN AUTOMÁTICA (ECONO COOL) también se puede cancelar pulsando el botón de DEFLECTOR (VANE). ¿En qué consiste la función de “desconexión automática (ECONO COOL)”? Si la dirección del aire cambia cada cierto tiempo (vaivén del aire), el ambiente se refresca más que si la dirección se mantiene siempre fija. Así pues, aunque la temperatura establecida aumente automáticamente en 4°F (2°C), puede utilizar esta función cuando el aparato esté en modo de refrigeración y así sentirse cómodo. Además, podrá ahorrar energía. Sp-7 JG79Y023H01_es.indd 7 7/30/2015 3:51:18 PM LIMPIEZA Instrucciones: • Durante la limpieza, apague el disyuntor o desenchúfelo de la toma de corriente. • Tenga cuidado de no tocar las partes metálicas con las manos. • No utilice bencina, polvo de pulimentación ni insecticida. • Use sólo detergentes suaves diluidos. • No exponga directamente al sol, al calor o a las llamas ninguna pieza con el fin de secarla. • No use agua con temperatura superior a 120°F (50°C). Filtro de limpieza de aire (Filtro de enzimas antialérgico) Filtro de aire (filtro de nanoplatino) • Límpielo cada 2 semanas • Elimine la suciedad con un aspirador o enjuáguelo con agua. • Después de limpiarlo con agua, déjelo secar completamente a la sombra. ¿Qué es el “filtro de nanoplatino”? El nanoplatino es una partícula cerámica que incluye una nanopartícula de platino. Las partículas se incorporan al material del filtro, que tiene como resultado proporcionar características antibacterias y desodorantes semipermanentes al filtro. El nanoplatino sobrepasa en rendimiento a los taninos (un bioflavonoide que se encuentra en el té verde). El filtro de nanoplatino utiliza este compuesto para mejorar la calidad del aire y también para eliminar bacterias y virus. Este filtro de aire tiene un efecto de durabilidad semipermanente incluso tras lavarlo con agua. Panel frontal Parte posterior del filtro de aire Cada 3 meses: • Elimine la suciedad con un aspirador. Si la suciedad no se puede eliminar con un aspirador: • Sumerja el filtro y su carcasa en agua emplada antes de enjuagarlos. • Tras el lavado, séquelo bien a la sombra. Cada año: • Cambie el filtro de aire por uno nuevo para un mejor rendimiento. • Número de las piezas MAC-408FT-E Tire para desacoplar del filtro de aire. Importante Gozne Orificio • Limpie los filtros con regularidad para un mejor rendimiento y para reducir el consumo de electricidad. • Los filtros sucios pueden provocar condensación en el acondicionador de aire que contribuye a la formación de hongos, como el moho. Por lo tanto, es recomendable limpiar los filtros cada 2 semanas. 1. Suba el panel frontal hasta que oiga un “clic”. 2. Sujete los goznes y tire de él para extraerlo, como se muestra en la ilustración anterior. • Pásele un paño suave seco o aclárelo con agua. • No lo empape en agua más de dos horas. • Séquelo bien en la sombra. 3. Instale el panel frontal siguiendo las instrucciones de extracción en orden inverso. Cierre el panel frontal de forma segura y pulse las posiciones que indican las flechas. Sp-8 JG79Y023H01_es.indd 8 7/30/2015 3:51:19 PM ● MANUAL DE INSTRUCCIONES ● SI CREE QUE HA OCURRIDO ALGÚN PROBLEMA Si después de comprobar estas cuestiones el acondicionador de aire sigue sin funcionar bien, póngase en contacto con su distribuidor. Síntoma La habitación no se refrigera lo suficiente. Síntoma Explicación y puntos de comprobación Unidad interior La unidad no puede ponerse en funcionamiento. • ¿Está activado el disyuntor? • ¿Está puesto el enchufe de la alimentación? • ¿Está configurada la activación del temporizador? Página 7 El deflector horizontal no se mueve. • ¿Está correctamente instalado el deflector horizontal? • ¿Está deformado el protector del ventilador? Cuando se vuelve a poner en marcha, la unidad tarda unos 3 minutos en funcionar. • Se trata de una instrucción del microprocesador para proteger la unidad. Espere. El vapor se descarga a través • El aire refrigerado de la unidad enfría rápidamente la humedad del interior de la de la salida de aire de la habitación y la convierte en vapor. unidad interior. La operación de oscilación del DEFLECTOR HORIZONTAL se suspende durante un tiempo y, a continuación, se reanuda. • Es para que la operación de oscilación del DEFLECTOR HORIZONTAL se realice con normalidad. La dirección del flujo de aire cambia en pleno funcionamiento. La dirección del deflector horizontal no puede ajustarse con el controlador remoto. • Cuando el aire acondicionado sigue funcionando en los modos REFRIGERACIÓN o DESHUMIDIFICACIÓN, después de llevar entre 30 minutos y 1 hora expulsando el aire hacia abajo, la dirección del flujo de aire se ajusta directamente en la posición hacia arriba para evitar que el agua condensada gotee. La unidad se pone en marcha • Estos modelos están equipados con la por sí misma al conectar la función de reinicio automático. Cuando se alimentación principal, aundesconecta la alimentación principal sin que no haya recibido la señal detener la unidad mediante el controlador del controlador remoto. remoto y se vuelve a encender, la unidad se pone en marcha automáticamente en el mismo modo seleccionado con el controlador remoto justo antes de que se desconectara la alimentación principal. Consulte “Función de reinicio automático” Página 5 . La unidad interior se decolora • Aunque, debido a agentes como la luz con el tiempo. ultravioleta y la temperatura, el plástico se vuelva amarillo, esto no tendrá ningún efecto en las funciones del producto. Unidad exterior El ventilador de la unidad exterior no gira aunque el compresor está funcionando. Aunque el ventilador empiece a girar, se para en seguida. • Cuando la temperatura exterior es baja durante la operación de refrigeración, el ventilador funciona intermitentemente para mantener suficiente capacidad de enfriamiento. En la unidad exterior hay una fuga de agua. • Durante la REFRIGERACIÓN o la DESHUMIDIFICACIÓN, el enfriamiento de los tubos y de las conexiones de los tubos hace que se condense el agua. Controlador remoto La pantalla del controlador remoto no aparece o se oscurece. La unidad interior no responde a la señal del controlador remoto. • ¿Están agotadas las pilas? Página 4 • ¿Es correcta la polaridad (+, -) de las pilas? Página 4 • ¿Se ha pulsado algún botón del controlador remoto de otros aparatos eléctricos? Explicación y puntos de comprobación No refrigera • ¿Es correcto el ajuste de la temperatura? Página 5 • ¿Es adecuado el ajuste del ventilador? Cambie la velocidad del ventilador a Alta o Muy Alta. Página 6 • ¿Están limpios los filtros? Página 8 • ¿Están limpios el ventilador o el intercambiador de calor de la unidad interior? • ¿Hay algún obstáculo que bloquee la entrada o salida de aire de las unidades interior o exterior? • ¿Se ha abierto una ventana o puerta? • Cuando se utiliza un ventilador de aire o una cocina de gas en la habitación, aumenta la carga de refrigeración, con lo cual el efecto de refrigeración resulta insuficiente. • Cuando la temperatura del aire exterior es alta, el efecto de refrigeración puede resultar insuficiente. • Podría tardar cierto tiempo en alcanzar la temperatura establecida o podría no alcanzarse dependiendo del tamaño de la habitación, la temperatura ambiente y similares. Flujo de aire El aire de la unidad interior tiene un olor raro. • ¿Están limpios los filtros? Página 8 • ¿Están limpios el ventilador o el intercambiador de calor de la unidad interior? • La unidad puede absorber el olor adherido a las paredes, alfombras, muebles, prendas, etc. y expulsarlo junto con el aire. Sonido Se oye un ruido de rotura. • Se trata de un sonido provocado por la dilatación/contracción del panel frontal, etc. a causa de los cambios de temperatura. Se oye un ruido de “burbujeo”. • Este ruido se oye cuando, al encenderse la campana o el ventilador, la manguera de drenaje absorbe aire del exterior y el agua que fluye por la manguera sale expulsada. Este ruido también se oye cuando hace mucho viento y entra aire en la manguera de drenaje. Se escucha un sonido mecánico en la unidad interior. • Corresponde al sonido de encendido/apagado del ventilador o del compresor. Se oye correr agua. • Se trata del ruido del refrigerante o del agua condensada que fluye por la unidad. A veces se oye un silbido. • Se trata del ruido que hace el refrigerante al cambiar la dirección de la circulación en el interior de la unidad. En los casos siguientes pare el equipo y póngase en contacto con su distribuidor. • Cuando cae o gotea agua de la unidad interior. • Cuando la luz de indicación de funcionamiento superior parpadea. • Cuando el disyuntor se desconecta con frecuencia. • Es posible que la señal del controlador remoto no se reciba en habitaciones en las que se utilicen fluorescentes de accionamiento electrónico (de tipo inversor, etc.). • El funcionamiento del acondicionador de aire interfiere con la capacidad de recepción del televisor o la radio. Puede ser necesario conectar el receptor afectado a un amplificador. • Si se oye un ruido anómalo. • Si se produce una fuga de refrigerante. Sp-9 JG79Y023H01_es.indd 9 7/30/2015 3:51:19 PM CUANDO EL ACONDICIONADOR DE AIRE NO SE VAYA A UTILIZAR DURANTE MUCHO TIEMPO 1 Ajuste a la máxima temperatura en el modo manual de REFRIGERACIÓN, y déjelo en funcionamiento durante 3 a 4 horas. Página 5 • Esto hace que se seque el interior de la unidad. • La humedad condensada en el aparato de aire acondicionado puede contribuir a la formación y expansión de hongos, como el moho. 2 3 4 Pulse para que se detenga. Desconecte el disyuntor o desconecte el enchufe de la alimentación. 2 3 4 TRABAJO ELÉCTRICO Lugar de instalación Procure no instalar el acondicionador de aire en los siguientes lugares. • Donde haya demasiado aceite para maquinaria. • En ambientes salobres, como las zonas costeras. • Donde haya gas sulfúrico, como en zonas de baños termales, alcantarillas o aguas residuales. • Donde se haya derramado aceite o haya mucho humo aceitoso en el ambiente (como en áreas donde se cocina o en fábricas, ya que las partes de plástico podrían alterarse o dañarse en estos lugares). • Donde existe equipo inalámbrico o de alta frecuencia. • Donde el aire de la salida de aire de la unidad exterior esté bloqueado. • Donde el sonido del funcionamiento o el del aire de la unidad exterior moleste a los vecinos. • Para el montaje de la unidad interior, se recomienda una altura de 5,9 pies a 7,5 pies (de 1,8 m a 2,3 m). Si fuera imposible, consulte a su distribuidor. La unidad exterior debe instalarse por lo menos a 10 pies (3 m) de las antenas para equipos de televisión, radio, etc. En zonas de mala recepción, si el funcionamiento del acondicionador de aire interfiere en la recepción de emisoras de radio o de televisión, aumente la separación entre la unidad exterior y la antena del aparatoafectado. Quite todas las pilas del controlador remoto. Al volver a usar el acondicionador de aire: 1 LUGAR DE INSTALACIÓN Y Lámpara fluorescente de tipo inversor Para evitar los efectos de una lámpara fluorescente, manténgase lo más alejado posible. Limpie el filtro del aire. Página 8 Compruebe que no estén bloqueadas las entradas y salidas de aire de las unidades interior/exterior. Compruebe que el cable de tierra esté conectado correctamente. Consulte la sección “PREPARACIÓN ANTES DE LA PUESTA EN MARCHA” y siga las instrucciones. Página 4 3 pies (1 m) o más Teléfono inalámbrico o portátil Mantenga un espacio suficiente para evitar distorsiones en imágenes o sonido. 3 pies (1 m) o más Para obtener la máxima eficiencia y prolongar la vida útil de la unidad exterior, esta debe instalarse en un sitio seco y bien ventilado. 4 pulg. (100 mm) o más Televisión Radio pared, etc. 8 pulg. (200 mm) o más 10 pies (3 m) o más Instalación eléctrica • Procure que el acondicionador de aire disponga de un circuito de alimentación exclusivo. • Procure que la capacidad del disyuntor sea la adecuada. Si tiene alguna pregunta, consulte a su distribuidor. ESPECIFICACIONES Intervalo garantizado de funcionamiento Refrigeración Margen superior Margen inferior Interior Exterior 90°F (32,2°C) DB 115°F (46,1°C) DB 73°F (22,8°C) WB — 67°F (19,4°C) DB 14°F (-10°C) DB 57°F (13,9°C) WB — DB : Temperatura seca WB : Temperatura húmeda Nota: 1. El valor del intervalo garantizado de funcionamiento es para la aplicación correspondiente al sistema 1:1. 2. Si la temperatura exterior se encuentra por debajo del margen inferior del intervalo garantizado de funcionamiento, es posible que la unidad exterior detenga el funcionamiento hasta que la temperatura exterior supere el margen inferior. Sp-10 JG79Y023H01_es.indd 10 7/30/2015 3:51:20 PM ● NOTICE D’UTILISATION ● TABLE DES MATIERES ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ CONSIGNES DE SECURITE NOMENCLATURE PREPARATIF D’UTILISATION SELECTION DES MODES DE FONCTIONNEMENT REGLAGE DE LA VITESSE DU VENTILATEUR ET DE LA DIRECTION DU FLUX D’AIR MODE SMART SET (REGLAGE INTELLIGENT) FONCTIONNEMENT EN MODE ECONO COOL FONCTIONNEMENT DE LA MINUTERIE (MARCHE/ARRET) NETTOYAGE EN PRESENCE D’UNE PANNE POTENTIELLE SI LE CLIMATISEUR DOIT RESTER LONGTEMPS INUTILISE LIEU D’INSTALLATION ET TRAVAUX ELECTRIQUES FICHE TECHNIQUE 1 3 4 5 6 6 7 7 8 9 10 10 10 CONSIGNES DE SECURITE • Avant toute utilisation, veuillez lire les “Consignes de sécurité” car cet appareil contient des pièces rotatives ou autres pouvant entraîner des risques d’électrocution. • Les consignes contenues dans cette section sont importantes pour la sécurité et doivent donc impérativement être respectées. Signification des symboles utilisés dans ce manuel : à éviter absolument. : suivre rigoureusement les instructions. • Après avoir lu cette notice, conservez-la avec le manuel d’installation à portée de main pour pouvoir la consulter aisément. : ne jamais insérer le doigt ou un objet long, etc. • Veillez à recevoir une carte de garantie de votre revendeur et vérifiez que la date d’achat et le nom du magasin, etc. sont saisis correctement. : ne jamais monter sur l’unité interne/externe et ne rien poser dessus. Symboles et leur signification AVERTISSEMENT: toute manipulation incorrecte peut avoir des conséquences graves, provoquer des blessures corporelles voire la mort de l’utilisateur. PRECAUTION: toute manipulation incorrecte peut avoir des conséquences graves selon les circonstances. AVERTISSEMENT Ne pas utiliser de raccord intermédiaire ou de rallonge pour brancher le cordon d’alimentation et ne pas brancher plusieurs appareils à une même prise secteur. • Ceci pourrait provoquer une surchauffe de l’appareil, un incendie ou un risque d’électrocution. Nettoyer la fiche d’alimentation électrique et l’insérer prudemment dans la prise secteur. • Une fiche d’alimentation électrique encrassée peut entraîner un risque d’incendie ou d’électrocution. Ne pas enrouler, tendre de façon excessive, modifier ou chauffer le cordon d’alimentation, et ne rien poser dessus. • Ceci pourrait provoquer un risque d’incendie ou d’électrocution. Ne pas enclencher/couper le disjoncteur ou débrancher/brancher la fiche d’alimentation électrique pendant le fonctionnement de l’appareil. • Des étincelles pourraient se produire et provoquer un risque d’incendie. • Toujours couper le disjoncteur ou débrancher la fiche d’alimentation électrique suite à l’arrêt de l’unité interne avec la télécommande. Il est déconseillé à toute personne de s’exposer au flux d’air froid pendant une période prolongée. • Ceci pourrait entraîner des problèmes de santé. L’utilisateur ne doit en aucun cas installer, déplacer, démonter, modifier ou tenter de réparer le climatiseur. • Toute manipulation incorrecte du climatiseur pourrait provoquer un risque d’incendie, d’électrocution, de blessure ou de fuite d’eau, etc. Contacter un revendeur. • Si le cordon d’alimentation est endommagé, il doit être remplacé par le fabricant ou le service après-vente du fabricant pour éviter tout risque potentiel. Lors de l’installation, du déplacement ou de l’entretien de l’appareil, veiller à ce qu’aucune substance autre que le réfrigérant spécifié (R410A) ne pénètre dans le circuit de réfrigération. • La présence d’une substance étrangère, comme de l’air dans le circuit, peut provoquer une augmentation anormale de la pression et causer une explosion, voire des blessures. • L’utilisation de réfrigérant autre que celui qui est spécifié pour le système provoquera une défaillance mécanique, un mauvais fonctionnement du système, ou une panne de l’appareil. Dans le pire des cas, la sécurité du produit pourrait être gravement mise en danger. : risque d’électrocution ! Attention ! : veiller à débrancher la fiche d’alimentation électrique de la prise secteur. : couper l’alimentation au préalable. Cet appareil n’est pas conçu pour être utilisé par des personnes (y compris des enfants) présentant des capacités physiques, sensorielles ou mentales réduites, ou manquant d’expérience et de connaissances, à moins qu’elles ne soient supervisées ou aient reçu des instructions relatives à l’utilisation de l’appareil par une personne responsable de leur sécurité. Les enfants doivent être surveillés de manière à ce qu’ils ne puissent pas jouer avec l’appareil. Ne jamais insérer le doigt ou tout autre objet dans les entrées ou sorties d’air. • La vitesse de rotation extrêmement rapide du ventilateur pendant le fonctionnement du climatiseur pourrait provoquer un accident. En cas d’anomalie (odeur de brûlé, etc.), arrêter le climatiseur et débrancher la fiche d’alimentation électrique ou couper le disjoncteur. • Si le climatiseur continue à fonctionner en présence d’une anomalie, une défaillance technique, un risque d’incendie ou d’électrocution ne sont pas à exclure. Dans ce cas, consulter un revendeur agréé. Si la fonction de refroidissement ou de chauffage du climatiseur est inopérante, cela peut indiquer la présence d’une fuite de réfrigérant. Dans ce cas, consulter un revendeur agréé. Si la réparation consiste à recharger l’appareil en réfrigérant, demander conseil auprès d’un technicien responsable de l’entretien. • Le réfrigérant contenu dans le climatiseur ne pose aucun problème de sécurité. En règle générale, aucune fuite ne doit se produire. Cependant, si le réfrigérant fuit et entre en contact avec la partie chauffante d’un appareil de chauffage à ventilation, d’un chauffage d’appoint, d’une cuisinière, etc., des substances toxiques se produiront. L’utilisateur ne doit jamais procéder au nettoyage intérieur de l’unité interne. Si vous pensez que la partie intérieure de l’unité doit être nettoyée, veuillez contacter votre revendeur. • L’utilisation d’un détergent inapproprié pourrait endommager les surfaces intérieures en plastique de l’unité et provoquer des fuites d’eau. Tout contact entre le détergent et les pièces électriques ou le moteur pourrait entraîner un dysfonctionnement, l’émission de fumées, voire un incendie. Fr-1 JG79Y023H01_fr.indd 1 7/23/2015 9:02:54 AM CONSIGNES DE SECURITE PRECAUTION Ne pas toucher à l’entrée d’air ou aux ailettes en aluminium de l’unité interne/externe. • Risque de blessures. Ne vaporiser ni insecticide ni substance inflammable sur l’appareil. • Ceci pourrait provoquer un incendie ou une déformation de l’appareil. Ne pas exposer un animal domestique ou une plante d’intérieur directement sous le courant d’air pulsé. • Le bien-être des animaux et des plantes pourrait en être affecté. Ne placer ni appareil électrique ni meuble sous l’unité interne/externe. • De l’eau pourrait s’écouler de l’appareil et les endommager ou provoquer une panne de leur système. Ne jamais laisser le climatiseur posé sur un support endommagé. • Il pourrait tomber et provoquer un accident. Veiller à ne pas monter sur une surface instable pour allumer ou nettoyer le climatiseur. • Risque de chute et de blessures. Ne jamais tirer sur le cordon d’alimentation. • Le fil central du cordon d’alimentation pourrait se rompre et provoquer un incendie. Ne jamais recharger ou tenter d’ouvrir les piles et ne pas les jeter au feu. • Les piles pourraient fuir et présenter un risque d’incendie ou d’explosion. Ne pas faire fonctionner le climatiseur pendant plus de 4 heures avec un taux d’humidité important (80% HR ou plus), et/ou lorsqu’une porte ou une fenêtre est ouverte. • Ceci peut provoquer de la condensation à l’intérieur du climatiseur, qui risque de s’écouler et de mouiller ou d’endommager le mobilier. • La présence d’humidité dans la climatisation peut contribuer à la croissance de certains champignons tels que la moisissure. Ne pas utiliser le climatiseur pour conserver des aliments, élever des animaux, faire pousser des plantes, ranger des outils de précision ou des objets d’art. • Leur qualité pourrait s’en ressentir, et le bien-être des animaux et des plantes pourrait en être affecté. Ne pas exposer des appareils à combustion directement sous la sortie d’air pulsé. • Une combustion imparfaite pourrait en résulter. Ne mettez jamais des piles dans la bouche pour quelque raison que ce soit pour éviter de les avaler par accident. • Le fait d’ingérer des piles peut entraîner un étouffement et/ou un empoisonnement. Avant de procéder au nettoyage du climatiseur, le mettre hors tension et débrancher la fiche d’alimentation électrique ou couper le disjoncteur. • La vitesse de rotation extrêmement rapide du ventilateur pendant le fonctionnement du climatiseur pourrait provoquer un accident. Si le climatiseur doit rester inutilisé pendant une période prolongée, débrancher la fiche d’alimentation électrique ou couper le disjoncteur. • Il pourrait s’encrasser et présenter un risque d’incendie ou d’électrocution. Remplacer les piles de la télécommande par des piles neuves du même type. • Ne jamais mélanger piles usagées et piles neuves ; ceci pourrait provoquer une surchauffe, une fuite ou une explosion. Si du liquide provenant des piles entre en contact avec la peau ou les vêtements, les rincer abondamment à l’eau claire. • Si du liquide alcalin entre en contact avec les yeux, les rincer abondamment à l’eau claire et contacter d’urgence un médecin. Si le climatiseur a été utilisé pendant plusieurs saisons consécutives, procéder à une inspection et à un entretien rigoureux en plus du nettoyage normal. • Une accumulation de saletés ou de poussière à l’intérieur du climatiseur peut être à l’origine d’une odeur désagréable, contribuer au développement de moisissures ou bloquer l’écoulement des condensats et provoquer une fuite d’eau de l’unité interne. Consulter un revendeur agréé pour procéder à une inspection et des travaux d’entretien nécessitant l’intervention de personnel qualifié et compétent. Ne pas actionner les commandes du climatiseur avec les mains mouillées. • Risque d’électrocution ! Ne pas nettoyer le climatiseur avec de l‘eau et ne placer ni vase ni verre d’eau dessus. • Ceci pourrait provoquer un risque d’incendie ou d’électrocution. Ne jamais marcher sur l’unité externe et ne rien poser dessus. • Risque de chute et de blessures. IMPORTANT Des filtres encrassés peuvent provoquer de la condensation dans le climatiseur, ce qui contribuera à la croissance de certains champignons tels que la moisissure. Il est donc recommandé de nettoyer les filtres à air toutes les 2 semaines. A propos de l’installation AVERTISSEMENT Consulter un revendeur agréé pour qu’il procède à l’installation du climatiseur. • L’utilisateur ne doit en aucun cas tenter d’installer le climatiseur lui-même ; seul du personnel qualifié et compétent est en mesure de le faire. Toute installation incorrecte du climatiseur pourrait être à l’origine de fuites d’eau et provoquer un risque d’incendie ou d’électrocution. Prévoir un circuit réservé à l’alimentation du climatiseur. • Dans le cas contraire, un risque de surchauffe ou d’incendie n’est pas à exclure. Ne pas installer l’appareil dans un endroit susceptible d’être exposé à des fuites de gaz inflammable. • L’accumulation de gaz autour de l’appareil entraîne des risques d’explosion. Raccorder correctement le climatiseur à la terre. • Ne jamais raccorder le câble de terre à un tuyau de gaz, une évacuation d’eau, un paratonnerre ou un câble téléphonique de mise à la terre. Une mise à la terre incorrecte pourrait provoquer un risque d’électrocution. PRECAUTION Installer un disjoncteur de fuites à la terre selon l’endroit où le climatiseur sera monté (pièce humide par ex.). • L’absence de disjoncteur de fuites à la terre peut entraîner un risque d’électrocution. Veiller à ce que l’eau de vidange s’écoule correctement. • Si l’écoulement des condensats est bouché, l’eau de vidange risque de s’écouler de l’unité interne/externe et d’endommager le mobilier. En présence d’une situation anormale Arrêter immédiatement le climatiseur et consulter un revendeur agréé. Si le climatiseur est utilisé conjointement avec un appareil à combustion, veiller à ce que la pièce soit parfaitement ventilée. • Une ventilation insuffisante pourrait provoquer un manque d’oxygène dans la pièce. Couper le disjoncteur par temps d’orage. • La foudre pourrait endommager le climatiseur. Fr-2 JG79Y023H01_fr.indd 2 7/23/2015 9:02:54 AM ● NOTICE D’UTILISATION ● NOMENCLATURE Unité interne Télécommande Affichage du mode de fonctionnement Panneau frontal Filtre à air (filtre nano-platinum) Filtre d’épuration d’air (filtre antiallergique à enzymes) Entrée d’air Témoin de remplacement de la pile Page 4 L’émission de bip(s) en provenance de l’unité interne indique la réception d’un signal. Touche Arrêt/ Marche (OFF/ ON) Touche de réglage de vitesse du VENTILATEUR Page 6 Touche de sélection du mode de fonctionnement Page 5 Sortie d’air Ailette horizontale Transmission des signaux Distance de réception du signal : Environ 20 ft. (6 m) Echangeur thermique Affichage Récepteur de télécommande Témoin de fonctionnement Interrupteur de secours Page 5 Touche de refroidissement économique (ECONO COOL) Page 7 Touche de commande des AILETTES Page 6 Touches de réglage de la température Pages 4, 5 Touche d’arrêt (OFF) de la minuterie Page 7 Touche de démarrage (ON) de la minuterie Page 7 Touche SMART SET Page 6 Touches de réglage de l’heure (TIME) Pages 4, 7 Avancer Reculer Touche de réglage de l’horloge (CLOCK) Page 4 Touche de réinitialisation (RESET) Page 4 Couvercle Le faire coulisser vers le bas pour l’ouvrir Support de la télécommande Unité externe Entrée d’air (arrière et latérale) Conduite de réfrigérant Tuyau d’évacuation des condensats Sortie d’air Sortie de condensats • Installez le support de la télécommande de façon à ce que l’unité interne puisse recevoir les signaux. Utilisez uniquement la télécommande fournie avec le climatiseur. N’en utilisez pas d’autres. Si plusieurs unités internes sont installées côté à côte, il se peut que le signal envoyé à une unité interne par la télécommande soit exécuté par une autre unité interne. L’apparence des unités externes peut varier d’un modèle à l’autre. Fr-3 JG79Y023H01_fr.indd 3 7/23/2015 9:02:55 AM PREPARATIF D’UTILISATION Avant la mise en marche : Insérez la fiche d’alimentation électrique dans la prise secteur et/ou enclenchez le disjoncteur. Insertion des piles dans la télécommande 4. 1. Appuyez sur la touche RESET. Retirez le couvercle avant. 2. 3. Insérez les piles alcalines AAA en plaçant d’abord le pôle négatif. Posez le couvercle avant. • Veillez à respecter la polarité des piles. • N’utilisez pas de piles au manganèse ou des piles qui présentent une fuite. Elles pourraient provoquer un dysfonctionnement de la télécommande. • N’utilisez pas de piles rechargeables. • Le témoin de remplacement de la pile s’allume lorsque la pile est presque déchargée. La télécommande cesse de fonctionner environ 7 jours après l’activation du témoin. • Remplacez toutes les piles par des piles de même type. • La durée de vie des piles est de 1 an environ. Cependant, les piles dont la date d’utilisation est dépassée durent moins longtemps. • Appuyez doucement sur RESET à l’aide d’un instrument fin. Si la touche RESET n’est pas enfoncée, la télécommande risque de ne pas fonctionner correctement. Réglage de l’heure 1. 3. Appuyez sur la touche CLOCK. 2. Appuyez à nouveau sur la touche CLOCK. Appuyez sur les touches TIME pour régler l’heure. A chaque pression sur ces touches, l’heure augmente/ diminue de 1 minute (10 minutes lors d’une pression prolongée). • Appuyez doucement sur CLOCK à l’aide d’un instrument fin. Changement des unités de température (˚F→˚C) L’unité prédéfinie est °F. 1. Appuyez sur RESET lorsque vous enfoncez les touches de température. • Appuyez doucement sur RESET à l’aide d’un instrument fin. • Pour changer l’unité de la température entre degrés Celsius (°C) et degrés Fahrenheit (°F), appuyez sur la touche RESET. Fr-4 JG79Y023H01_fr.indd 4 7/23/2015 9:02:55 AM ● NOTICE D’UTILISATION ● SELECTION DES MODES DE FONCTIONNEMENT Mode de SENSATION (I FEEL) Le climatiseur sélectionne le mode de fonctionnement selon la température de la pièce si le mode de SENSATION est activé. Si la température de la pièce est supérieure à 77°F (25°C), le mode de REFROIDISSEMENT est sélectionné (température programmée : 75°F [24°C]). Si elle est inférieure à 77°F (25°C), le mode de DESHUMIDIFICATION est sélectionné. Toutefois, si le climatiseur est arrêté, puis redémarré dans les 2 heures, il fonctionnera dans le mode sélectionné précédemment. Remarque : En mode de REFROIDISSEMENT, la température programmée peut ne pas changer si la température de la pièce est supérieure de 4°F (2°C) à la température programmée. Dans ce cas, attendez que la température de la pièce soit proche de 4°F (2°C) de la température programmée. Mode de REFROIDISSEMENT Le confort de l’air frais à votre température. Remarque : Ne faites pas fonctionner le climatiseur en mode de REFROIDISSEMENT lorsque les températures extérieures sont extrêmement basses. (inférieure à 14°F [-10°C]). L’eau de condensation présente à l’intérieur duclimatiseur risque de s’écouler et d’endommager le mobilier, etc. Mode de DESHUMIDIFICATION 1 2 Appuyez sur la touche ment du climatiseur. Mode de VENTILATEUR Appuyez sur la touche pour sélectionner le mode de fonctionnement. Chaque nouvelle pression sur cette touche vous permet de passer d’un mode à l’autre dans l’ordre suivant : (SENSATION) 3 pour lancer le fonctionne- (REFROIDISSEMENT) (DESHUMIDIFICATION) (VENTILATEUR) Appuyez sur les touches ou pour régler la température. Chaque nouvelle pression sur ces touches vous permet d’augmenter ou de diminuer la température de 1°F (1°C). Appuyez sur la touche ment du climatiseur. Eliminez l’humidité de votre pièce. Il se peut que la pièce refroidisse légèrement. Il n’est pas possible de régler la température en mode de DESHUMIDIFICATION. pour arrêter le fonctionne- • Vous avez la possibilité de recouvrer les mêmes réglages lors de la . prochaine utilisation du climatiseur en appuyant simplement sur Témoin de fonctionnement Permet de faire circuler l’air dans la pièce. Fonctionnement d’urgence Lorsqu’il est impossible d’utiliser la télécommande... Vous pouvez lancer le fonctionnement d’urgence en appuyant sur l’interrupteur de secours (E.O.SW) de l’unité interne. A chaque fois que vous appuyez sur l’interrupteur de secours (E.O.SW), le fonctionnement du climatiseur change dans l’ordre suivant : Témoin de fonctionnement REFROIDISSEMENT d’urgence Arrêt Température programmée: 75°F (24°C) Vitesse du ventilateur: moyenne Ailette horizontale: auto Remarque : Les premières 30 minutes de fonctionnement constitue un essai de fonctionnement. La commande de température ne fonctionne pas, et la vitesse du ventilateur est réglée sur Rapide. Le témoin de fonctionnement indique l’état de fonctionnement du climatiseur. Témoin Etat de fonctionnement Température de la pièce Le climatiseur fonctionne de façon Environ 4°F (2°C) d’écart à atteindre la température pro- minimum avec la tempégrammée rature programmée La température de la pièce se Environ 2 à 4°F (1 à 2°C) rapproche de la température pro- d’écart avec la tempéragrammée ture programmée Allumé Eteint Fonction de redémarrage automatique En cas de coupure d’électricité ou d’interruption de l’alimentation principale pendant le fonctionnement du climatiseur, la “fonction de redémarrage automatique” prend automatiquement le relais et permet de remettre le climatiseur en marche en respectant le mode sélectionné à l’aide la télécommande juste avant la coupure de l’alimentation. Si vous avez recours au fonctionnement manuel de la minuterie, le réglage de la minuterie sera annulé et le climatiseur redémarrera au retour de l’alimentation. Si vous ne voulez pas utiliser cette fonction, veuillez vous adresser au représentant du service technique afin qu’il modifie le réglage du climatiseur. Fr-5 JG79Y023H01_fr.indd 5 7/23/2015 9:02:56 AM REGLAGE DE LA VITESSE DU VENTILA- TEUR ET DE LA DIRECTION DU FLUX D’AIR Appuyez sur la touche pour sélectionner la vitesse du ventilateur. Chaque nouvelle pression sur cette touche vous permet de modifier la vitesse du ventilateur dans l’ordre suivant : (AUTO) (Silencieux) (Faible) (Moy.) (Elevée) (Très élevée) • L’unité interne émet deux bips courts lorsqu’elle est réglée en mode AUTO. • Augmentez la vitesse du ventilateur pour refroidir la pièce plus rapidement. Il est recommandé de réduire la vitesse du ventilateur dès que la pièce est fraîche. • Diminuez la vitesse du ventilateur pour un fonctionnement silencieux. Appuyez sur la touche pour sélectionner la direction du flux d’air. Chaque nouvelle pression sur cette touche vous permet de modifier la direction du flux d’air dans l’ordre suivant : (AUTO) (1) (2) (3) (4) (5) (OSCILLATION) • L’unité interne émet deux bips courts lorsqu’elle est réglée en mode AUTO. Direction du flux d’air (AUTO)..........L’ailette est réglée pour fournir la direction de flux d’air la plus efficace. : position horizontale. (Manuel) ........Pour une climatisation efficace, sélectionnez la position supérieure pour le mode REFROIDISSEMENT/DESHUMIDIFICATION et la position inférieure pour la VENTILATION. Si la position (4) ou (5), est sélectionnée en mode de REFROIDISSEMENT/DESHUMIDIFICATION, l’ailette se place automatiquement en position vers le haut au bout de 0,5 à 1 heure pour éviter la formation de gouttes de condensation. MODE SMART SET (REGLAGE INTELLIGENT) 1 2 Appuyez sur en mode REFROIDISSEMENT ou ECONO COOL pour sélectionner le mode SMART SET (REGLAGE INTELLIGENT). Réglez la température, la vitesse du ventilateur et la direction du flux d’air. • Pour sélectionner les mêmes réglages par la suite, il vous suffira d’ap. puyer sur • Il est possible d’enregistrer un jeu de réglages. • Sélectionnez la température, la vitesse du ventilateur et la direction du flux d’air appropriées pour votre local. Appuyez une nouvelle fois sur pour annuler le mode SMART SET (REGLAGE INTELLIGENT). • Une pression sur la touche MODE permet également d’annuler le mode SMART SET (REGLAGE INTELLIGENT). MODE SMART SET (REGLAGE INTELLIGENT) Une fonction programmable simplifiée permet de rappeler le réglage favori (pré. Une seconde programmé) à l’aide d’une simple pression sur la touche pression sur la touche permet de revenir instantanément au réglage précédent. Exemple d’utilisation: 1. Mode économie d’énergie Augmentez la température de 4°F (2°C) à 6°F (3°C) en mode REFROIDISSEMENT. Ce réglage convient pour les pièces inoccupées ou pendant la nuit. 2. Enregistrement des paramètres fréquemment utilisés Enregistrez votre réglage préféré pour le mode REFROIDISSEMENT/ECONO COOL. Il vous suffira ensuite d’une simple pression sur la touche pour rappeler votre réglage favori. (Oscillation) ...L’ailette se déplace de haut en bas par intermittence. ■ Pour modifier la direction horizontale du flux d’air. Déplacez manuellement l’ailette verticale avant de faire fonctionner le climatiseur. Fr-6 JG79Y023H01_fr.indd 6 7/23/2015 9:02:58 AM ● NOTICE D’UTILISATION ● FONCTIONNEMENT EN MODE ECONO COOL FONCTIONNEMENT DE LA MI- NUTERIE (MARCHE/ARRET) 1 Appuyez sur les touches ou pendant le fonctionnement du climatiseur pour régler la minuterie. (Démarrage de la minuterie [ON]) : Le climatiseur démarrera (ON) à l’heure programmée. (Arrêt de la minuterie [OFF]) : Le climatiseur s’arrêtera (OFF) à l’heure programmée. * ou clignote. * La minuterie doit être réglée à l’heure juste. Page 4 2 Appuyez sur les touches (Augmenter) et (Diminuer) pour régler l’heure de la minuterie. Chaque pression sur ces touches vous permet de faire avancer ou reculer l’heure programmée de 10 minutes. ou clignote. • Réglez la minuterie lorsque 3 Appuyez sur la touche en mode de REFROIDISSEMENT Page 5 pour lancer le fonctionnement ECONO COOL. L’unité effectue un balayage oscillant vertical en différents cycles en fonction de la température du flux d’air. La température programmée est automatiquement réglée à 4°F (2°C) au-dessus de la température normale. Appuyez à nouveau sur les touches ou pour annuler le fonctionnement de la minuterie. Remarque : • Les fonctions de démarrage (ON) et d’arrêt (OFF) de la minuterie peuvent indique l’ordre d’application des être réglées conjointement. Le symbole modes de fonctionnement de la minuterie. • En cas de coupure d’électricité survenant après le réglage de la minuterie (MARCHE/ARRET), voir Page 5 “Fonction de redémarrage automatique”. Appuyez à nouveau sur la touche pour annuler le fonctionnement en mode ECONO COOL. • La touche VANE permet également d’annuler le fonctionnement en mode ECONO COOL. Qu’est-ce que le mode de REFROIDISSEMENT ECONOMIQUE “ECONO COOL” ? L’oscillation de l’air pulsé (changement de direction) permet de rafraîchir davantage une pièce qu’un flux d’air constant. Ainsi, même si la température programmée est automatiquement réglée 4°F (2°C) au dessus de la température normale, il est possible d’utiliser le mode de refroidissement tout en conservant un certain niveau de confort. De plus, vous économisez de l’énergie. Fr-7 JG79Y023H01_fr.indd 7 7/23/2015 9:02:59 AM NETTOYAGE Instructions : • Coupez l’alimentation ou le disjoncteur avant de procéder au nettoyage du climatiseur. • Veillez à ne pas toucher les parties métalliques avec les mains. • N’utilisez ni benzine, ni diluant, ni poudre abrasive, ni insecticide. • Utilisez uniquement un détergent doux dilué avec de l’eau. • N’exposez pas les pièces aux rayons directs du soleil, à la chaleur ou à une flamme pour les faire sécher. • N’utilisez pas d’eau dont la température est supérieure à 120°F (50°C). Filtre d’épuration d’air (filtre antiallergique à enzymes) Filtre à air (filtre nano-platinum) • Nettoyez toutes les 2 semaines. • Eliminez la saleté accumulée sur le filtre avec un aspirateur ou en passant le filtre sous l’eau. • Après avoir passé le filtre sous l’eau, laissez-le sécher à l’ombre. Qu’est-ce qu’un “filtre nano-platinum” ? Le nano-platinum est une particule en céramique qui contient une nanoparticule de platine. Ces particules sont incorporées au matériau du filtre dans le but d’offrir des caractéristiques antibactériennes et désodorisantes semi-permanentes au filtre. Les performances du nano-platinum dépassent de loin celles de la catéchine (un bioflavonoïde que l’on trouve dans le thé vert). Le filtre nano-platinum utilise cette substance non seulement pour améliorer la qualité de l’air mais également pour éviter la prolifération de bactéries et de virus dans la pièce. Les caractéristiques de ce filtre à air sont semi-permanentes, c’est-à-dire qu’elles se prolongent au-delà du nettoyage du filtre à l’eau. Panneau frontal Charnière Trou 1. Soulevez le panneau frontal jusqu’à ce que vous entendiez un déclic. 2. Maintenez les charnières et tirez sur le panneau pour le retirer comme indiqué sur l’illustration ci-dessus. • Essuyez-le avec un chiffon doux et sec ou lavez-le à l’eau. • Ne le faites pas tremper dans l’eau pendant plus de deux heures. • Faites-le sécher correctement à l’ombre. 3. Reposez le panneau frontal en suivant la procédure de dépose en sens inverse. Refermez correctement le panneau frontal et appuyez sur les repères indiqués par les flèches. Envers du filtre à air Tous les 3 mois : • Enlever la saleté à l’aide d’un aspirateur. Lorsque cela ne suffit pas : • Faites tremper le filtre et son cadre dans de l’eau tiède avant de les nettoyer. • Lorsqu’ils sont propres, faites-les sécher correctement à l’ombre. Tous les ans : • Pour des performances optimales, remplacer le filtre d’épuration d’air. • Référence MAC-408FT-E Tirez sur le panneau frontal pour le retirer du filtre à air. Important • Nettoyez régulièrement les filtres pour obtenir des performances optimales et réduire votre consommation d’électricité. • Des filtres encrassés peuvent provoquer de la condensation dans le climatiseur, ce qui contribuera à la croissance de certains champignons tels que la moisissure. Il est donc recommandé de nettoyer les filtres à air toutes les 2 semaines. Fr-8 JG79Y023H01_fr.indd 8 7/23/2015 9:02:59 AM ● NOTICE D’UTILISATION ● EN PRESENCE D’UNE PANNE POTENTIELLE Suite à la vérification de ces points, si le climatiseur ne fonctionne toujours pas correctement, ne vous en servez plus et consultez votre revendeur. Symptôme Explication & points à vérifier Symptôme Impossible de refroidir suffisamment la pièce. Unité interne L’unité ne fonctionne pas. • Le disjoncteur est-il enclenché ? • La fiche d’alimentation est-elle branchée ? • La minuterie de mise en marche (ON) estelle programmée ? Page 7 L’ailette horizontale ne bouge pas. • Les ailettes horizontales sont-elles installées correctement ? • La grille de protection du ventilateur est-elle déformée ? L’unité ne peut pas être remise en marche dans les 3 minutes qui suivent sa mise hors tension. • Cette disposition a été prise pour protéger le climatiseur conformément aux instructions du microprocesseur. Veuillez patienter. De la buée s’échappe de la sortie d’air de l’unité interne. • L’air frais pulsé par le climatiseur refroidit rapidement l’humidité présente dans la pièce, et la transforme en buée. L’oscillation de l’AILETTE HORIZONTALE est suspendue un certain temps, puis restaurée. • Cela permet l’oscillation correcte de l’AILETTE HORIZONTALE. La direction de l’air pulsé va- • Lorsque le climatiseur est en mode de REFROIDISSEMENT ou de DESHUMIDIrie pendant le fonctionnement FICATION, s’il fonctionne en continu entre de l’unité. 0,5 et 1 heure avec le flux d’air orienté vers La télécommande ne permet le bas, la direction de l’air pulsé est automapas de régler la direction de tiquement placée en position vers le haut l’ailette horizontale. afin d’empêcher l’eau de condensation de s’écouler. L’unité démarre automatique- • Ces modèles sont équipés d’une fonction ment lors de la mise sous tende redémarrage automatique. Si vous sion, sans avoir reçu aucun coupez l’alimentation principale sans signal de la télécommande. arrêter le climatiseur avec la télécommande puis remettez sous tension, le climatiseur démarre automatiquement dans le même mode que celui qui avait préalablement été sélectionné à l’aide de la télécommande avant la mise hors tension. Consultez la section “Fonction de redémarrage automatique” Page 5 . L’unité interne se décolore avec le temps. • Même si le plastique jaunit sous l’influence de certains facteurs tels que le rayonnement ultraviolet et la température, ceci n’a aucun effet sur les fonctionnalités du produit. Unité externe Le ventilateur de l’unité externe ne tourne pas alors que le compresseur fonctionne correctement. Même s’il se met à tourner, le ventilateur s’arrête aussitôt. • Lorsque la température extérieure est basse, le ventilateur fonctionne de façon intermittente en mode de refroidissement pour maintenir une capacité de refroidissement suffisante. De l’eau s’écoule de l’unité externe. • En mode de REFROIDISSEMENT et de DESHUMIDIFICATION, la tuyauterie et les raccords de tuyauterie sont refroidis et un certain degré de condensation peut se produire. Télécommande Aucun affichage sur la télécommande ou affichage indistinct. L’unité interne ne répond pas au signal de la télécommande. • Les piles sont-elles déchargées ? Page 4 • La polarité (+, -) des piles est-elle correcte ? Page 4 • Avez-vous appuyé sur les touches de télécommandes d’autres appareils électriques ? Explication & points à vérifier Le climatiseur ne refroidit pas correctement • Le réglage de la température est-il adapté ? Page 5 • Le réglage du ventilateur est-il adapté ? Veuillez changer la vitesse du ventilateur à Elevée ou Très élevée. Page 6 • Les filtres sont-il propres ? Page 8 • Le ventilateur ou l’échangeur thermique de l’unité interne sont-ils propres ? • L’entrée ou la sortie d’air des unités interne et externe sont-elles obstruées ? • Y a t-il une fenêtre ou une porte ouvertes ? • Si vous utilisez un ventilateur ou une gazinière dans la pièce, la charge de refroidissement augmente, et le refroidissement ne peut se faire de manière satisfaisante. • Lorsque la température extérieure est élevée, il se peut que le refroidissement ne se fasse pas de manière satisfaisante. • Il est possible que l’unité prenne un certain temps afin d’atteindre la température de réglage, voire qu’elle ne l’atteigne pas en fonction de la taille de la pièce, la température ambiante, etc. Flux d’air L’air qui sort de l’unité interne a une odeur étrange. • Les filtres sont-il propres ? Page 8 • Le ventilateur ou l’échangeur thermique de l’unité interne sont-ils propres ? • Le climatiseur peut être imprégné de l’odeur d’un mur, d’un tapis, d’un meuble, de vêtements, etc. et la rejeter avec l’air pulsé. Bruit Des craquements se produisent. • Ce phénomène provient de l’expansion/la contraction du panneau frontal, etc. en raison des variations de température. Un “murmure” est perceptible. • Ce bruit est perceptible lorsque de l’air frais pénètre dans le tuyau d’écoulement ; il provient de l’évacuation de l’eau présente dans le tuyau lors de l’ouverture du bouchon ou de la rotation du ventilateur. Ce bruit est également perceptible lorsque de l’air frais pénètre dans le tuyau d’écoulement par vents violents. Un bruit mécanique provient de l’unité interne. • Il s’agit du bruit de mise en marche/arrêt du ventilateur ou du compresseur. Un bruit d’écoulement d’eau se produit. • Ce bruit peut provenir de la circulation du réfrigérant ou de l’eau de condensation dans le climatiseur. Un sifflement est parfois perceptible. • Il s’agit du bruit que fait le réfrigérant à l’intérieur du climatiseur lorsqu’il change de sens. Dans les cas suivants, arrêtez le climatiseur et consultez votre revendeur. • Si de l’eau s’écoule ou goutte de l’unité interne. • Si le témoin de fonctionnement supérieur clignote. • Si le disjoncteur saute régulièrement. • L’unité interne peut ne pas recevoir les signaux de la télécommande dans une pièce dont le système d’éclairage est à lampes fluorescentes (à oscillateur intermittent, etc.). • Le fonctionnement du climatiseur interfère avec la réception radio ou TV. Il peut s’avérer nécessaire de brancher un amplificateur sur l’appareil concerné. • Si l’unité émet un bruit anormal. • Si du réfrigérant fuit. Fr-9 JG79Y023H01_fr.indd 9 7/23/2015 9:02:59 AM SI LE CLIMATISEUR DOIT RESTER LONGTEMPS INUTILISE 1 Sélectionnez manuellement le mode de REFROIDISSEMENT et réglez la température la plus élevée ; faites fonctionner le climatiseur entre 3 et 4 heures. Page 5 • Cette opération permet de sécher l’intérieur du climatiseur. • La présence d'humidité dans la climatisation contribue à créer un terrain favorable à la croissance de certains champignons tels que la moisissure. 2 3 4 Appuyez sur climatiseur. pour arrêter le fonctionnement du Débranchez la fiche d’alimentation électrique et/ou coupez le disjoncteur. 2 3 4 TRAVAUX ELECTRIQUES Lieu d’installation Evitez d’installer le climatiseur dans les endroits suivants. • En présence d’une grande quantité d’huile de machine. • Dans les régions où l’air est très salin, comme en bord de mer. • En présence de gaz sulfurés qui se dégagent par exemple des sources chaudes ou des eaux usées. • Dans des endroits exposés à des projections d’huile ou dont l’atmosphère est chargée d’huile (comme par exemple les cuisines et les usines en raison du risque d’altération ou d’endommagement des propriétés des matériaux plastiques). • En présence d’équipements haute fréquence ou sans fil. • Dans un endroit où la sortie d’air de l’unité externe est susceptible d’être obstruée. • Dans un endroit où le bruit de fonctionnement ou la pulsation d’air provenant de l’unité externe représentent une nuisance pour le voisinage. • La hauteur de montage recommandée pour l’unité interne est de 5,9 ft. à 7,5 ft. (1,8 m à 2,3 m). Si cela n’est pas possible, consultez votre revendeur. L’unité externe doit être installée à 10 ft. (3 m) minimum des antennes de TV, radio, etc. Dans des régions où la réception est faible, éloigner davantage l’unité externe et l’antenne de l’appareil concerné si le fonctionnement du climatiseur interfère avec la réception radio ou TV. Retirez toutes les piles de la télécommande. Lorsque le climatiseur doit être remis en service : 1 LIEU D’INSTALLATION ET Lampes fluorescentes à Eloignez le plus possi- oscillateur intermittent ble le climatiseur d’une lampe fluorescente pour éviter tout parasitage. Maintenez un espace suffisant pour éviter toute distorsion de l’image ou du son. Nettoyez le filtre à air. Page 8 Veillez à ce que l’entrée et la sortie d’air des unités interne et externe ne soient pas obstruées. Veillez à raccorder correctement le câble de mise à la terre. Reportez-vous à la section “PREPARATIF D’UTILISATION” et suivez les instructions. Page 4 3 ft. (1 m) minimum Téléphone sans fil ou téléphone portable 3 ft. (1 m) minimum Pour une efficacité maximale et une longévité optimale, l’unité externe doit être installée dans un endroit sec et bien aéré. 4 in. (100 mm) minimum TV Radio mur, etc. 8 in. (200 mm) minimum 10 ft. (3 m) minimum Travaux électriques • Veuillez prévoir un circuit réservé à l’alimentation du climatiseur. • Veuillez respecter la puissance électrique du disjoncteur. Dans le doute, veuillez consulter votre revendeur. FICHE TECHNIQUE Gamme opérationnelle garantie Limite Refroi- supérieure disseLimite ment inférieure Interne Externe 90°F (32,2°C) DB 115°F (46,1°C) DB 73°F (22,8°C) WB — 67°F (19,4°C) DB 14°F (-10°C) DB 57°F (13,9°C) WB — DB : Bulbe sec WB : Bulbe humide Remarque: 1. Les valeurs de la gamme opérationnelle garantie sont valables pour le système 1:1. 2. Si la température extérieure est en-dessous de la limite inférieure de la gamme opérationnelle garantie, il se peut que l’unité externe s’arrête jusqu’à ce que la température extérieure dépasse la limite inférieure. Fr-10 JG79Y023H01_fr.indd 10 7/23/2015 9:03:00 AM HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN JG79Y023H01 01-JG79Y023H01_Cover.indd 2 7/31/2015 5:11:12 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Mitsubishi MSYGL15NA-U1 El manual del propietario

Categoría
Acondicionadores de aire de sistema dividido
Tipo
El manual del propietario