OPERATION AND MAINTENANCE MANUAL FOR
MODELS 2400P AND 3000P
TWIN BLADE IMPULSE WRENCHES
Models 2400P and 3000P Impulse Wrenches are designed for assembly operations
which require high speed rundown of fasteners with consistent torque delivery and
reduced torque reaction.
Ingersoll–Rand is not responsible for customer modification of tools for applications on
which Ingersoll–Rand was not consulted.
IMPORTANT SAFETY INFORMATION ENCLOSED.
READ THIS MANUAL BEFORE OPERATING TOOL.
IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PLACE THE INFORMATION
IN THIS MANUAL INTO THE HANDS OF THE OPERATOR.
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
PLACING TOOL IN SERVICE
Always operate, inspect and maintain this tool in
accordance with American National Standards
Institute Safety Code for Portable Air Tools
(ANSI B186.1).
For safety, top performance, and maximum
durability of parts, operate this tool at 90 psig
(6.2 bar/620 kPa) maximum air pressure at the inlet
with 1/2” (13 mm) inside diameter air supply hose.
Always turn off the air supply and disconnect the
air supply hose before installing, removing or
adjusting any accessory on this tool, or before
performing any maintenance on this tool.
Do not use damaged, frayed or deteriorated air
hoses and fittings.
Be sure all hoses and fittings are the correct size
and are tightly secured. See Dwg. TPD905–1 for a
typical piping arrangement.
Always use clean, dry air at 90 psig
(6.2 bar/620 kPa) maximum air pressure. Dust,
corrosive fumes and/or excessive moisture can ruin
the motor of an air tool.
Do not lubricate tools with flammable or volatile
liquids such as kerosene, diesel or jet fuel.
Do not remove any labels. Replace any damaged
label.
USING THE TOOL
Always wear eye protection when operating or
performing maintenance on this tool.
Always wear hearing protection when operating
this tool.
Keep hands, loose clothing and long hair away from
rotating end of tool.
Anticipate and be alert for sudden changes in
motion during start up and operation of any power
tool.
Keep body stance balanced and firm. Do not
overreach when operating this tool. High reaction
torques can occur at or below the recommended air
pressure.
Tool shaft may continue to rotate briefly after
throttle is released.
Air powered tools can vibrate in use. Vibration,
repetitive motions or uncomfortable positions may
be harmful to your hands and arms. Stop using any
tool if discomfort, tingling feeling or pain occurs.
Seek medical advice before resuming use.
Use accessories recommended by Ingersoll–Rand.
Use only impact sockets and accessories. Do not use
hand (chrome) sockets or accessories.
This tool is not designed for working in explosive
atmospheres.
This tool is not insulated against electric shock.
The use of other than genuine Ingersoll–Rand replacement parts may result in safety hazards, decreased tool
performance, and increased maintenance, and may invalidate all warranties.
Repairs should be made only by authorized trained personnel. Consult your nearest Ingersoll–Rand Authorized
Servicenter.
F
E
P
2
WARNING LABEL IDENTIFICATION
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
Always wear eye protection
when operating or perform-
ing maintenance on this
tool.
WARNING
WARNING
Always wear hearing
protection when operating
this tool.
Always turn off the air sup-
ply and disconnect the air
supply hose before install-
ing, removing or adjusting
any accessory on this tool,
or before performing any
maintenance on this tool.
WARNING
Air powered tools can vibrate
in use. Vibration, repetitive
motions or uncomfortable po-
sitions may be harmful to your
hands and arms. Stop using
any tool if discomfort, tingling
feeling or pain occurs. Seek
medical advice before resum-
ing use.
WARNING
Do not carry the tool by
the hose.
WARNING
WARNING
Do not use damaged, frayed
or deteriorated air hoses
and fittings.
WARNING
Keep body stance balanced
and firm. Do not overreach
when operating this tool.
WARNING
Operate at 90 psig (6.2 bar/
620 kPa) Maximum air pressure.
90 psig
(6.2bar/620kPa)
ADJUSTMENTS
TORQUE ADJUSTMENT
To adjust the torque on these Twin Blade Impulse
Wrenches, proceed as follows:
1. Remove the Adjustment Hole Plug.
2. Rotate the Drive Shaft until the Torque Adjustment
Screw is visible in the opening.
3. Using a 1.5 mm hex wrench, rotate the Adjustment
Screw clockwise to increase the torque output and
counterclockwise to decrease the torque output. Do
not rotate the Oil Plug.
Make all final adjustments at the job.
4. Replace the Adjustment Hole Plug.
CHANGING THE MECHANISM FLUID
To change the Mechanism Fluid in the Impulse Mechanism,
proceed as follows:
1. Remove the Rubber Housing Boot.
2. Using a hex wrench, remove the four Hammer Case
Cap Screws and Lock Washers. Lift the Hammer Case
off the Motor Housing over the Drive Shaft. Remove
the Hammer Case Gasket.
3. Lift the assembled mechanism off the Rotor.
4. Using a 2 mm hex wrench, rotate the Torque
Adjustment Screw clockwise until the Screw stops.
Rotate the Screw counterclockwise until it stops or
makes six complete revolutions.
5. Using a 2.5 mm hex wrench, unscrew and remove the
Oil Plug. Remove the Oil Plug Seal and Oil Plug Seal
Support.
6. With the oil plug opening downward over a container,
rotate the Drive Shaft to purge the fluid from the
mechanism.
7. Thread the Tee Wrench included with the Tool Kit
(Part No. 1900P–99) into the Piston Stop Assembly
that is 180 degrees from the Torque Adjustment Screw
and pull the Stop Assembly toward the output end of
the mechanism until it stops.
8. Using the syringe and fluid from the Fluid
Replacement Kit (Part No. EQ106S–K400), fill the
mechanism with the fluid furnished in the Kit until the
fluid overflows the fill hole. Model 2400P will require
30 cc of fluid, Model 3000P, 43 cc.
See Dwg. TPD1265.
DO NOT SUBSTITUTE ANY OTHER FLUID.
Failure to use the impulse mechanism fluid
provided could damage the tool, increase
maintenance and decrease performance. Use only
clean fluid in these tools.
3
ADJUSTMENTS
(Dwg. TPD1265)
9. Submerge the fill opening in the remainder of the fluid,
and using a wrench, rotate the Drive Shaft to purge any
remaining air from the system.
10. Remove the mechanism from from the fluid and use
the Tee Wrench to push the Piston Stop Assembly
slowly downward until fluid flows from the fill
opening.
11. Thread the Oil Plug with the Oil Plug Seal and Seal
Support into the mechanism until it is snug.
12. Using a 2 mm hex wrench, turn the Torque Adjustment
Screw clockwise until it stops. This is the maximum
torque position.
13. Wipe the outside of the mechanism dry and clean and
remove the Oil Chamber Plug. Using the syringe,
withdraw 0.5 cc of fluid from 2400P models and 1.0 cc
from 3000P models.
14. Install the Oil Chamber Plug and tighten it between 20
and 25 inlb (2.3 and 2.8 Nm) torque.
15. Position a new Hammer Case Gasket on the Motor
Housing and install the assembled mechanism on the
rotor shaft.
16. Place the Hammer Case Cover over the Drive Shaft
against the Housing and Gasket. Install the four
Hammer Case Cap Screws and Lock Washers. Tighten
each Screw between 45 and 50 inlb (5.1 and 5.6 Nm)
torque.
17. Install the Rubber Housing Boot on the tool.
PLACING TOOL IN SERVICE
LUBRICATION
IngersollRand No. 50 IngersollRand No. 67
IngersollRand Fluid Part
No. EQ106S4001
Always use an air line lubricator with these tools.
We recommend the following FilterLubricatorRegulator
Unit:
USA No. C1803FKG028
After each 20 000 cycles, or as experience indicates, drain
and refill the Impulse Unit Drive Assembly as instructed in
this manual using the Fluid Replacement Kit (Part
No. EQ106SK400). Lubricate the hex drive and the output
shaft before assembly.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
FILTER
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
COMPRESSOR
(Dwg. TPD9051)
HOW TO ORDER AN IMPULSE WRENCH
Model Free Speed Recommended Torque Range
Soft Draw Hard Slam
ftlb Nm ftlb Nm
PISTOL GRIP with 1/2 SQUARE DRIVE
2400P 4,300 3580 47108 107170 145230
PISTOL GRIP with 3/4 SQUARE DRIVE
3000P 4,500 60110 82150 124210 169286
Adressez toutes vos communications au Bureau
IngersollRand ou distributeur le plus proche.
IngersollRand Company 2000
Imprimé au Japon
MANUEL DEXPLOITATION ET DENTRETIEN
DES CLÉS HYDROPNEUMATIQUES À DOUBLE
PALETTE MODÈLES 2400P ET 3000P
NOTE
Les clés hydropneumatiques à double palette Modèles 2400P et 3000P sont destinées aux opérations
dassemblage nécessitant une grande vitesse de serrage avec une régularité du couple et un serrage
virtuellement sans réaction sur lopérateur.
IngersollRand ne peut être tenu responsable de la modification des outils par le client pour les adapter à
des applications qui nont pas été approuvées par IngersollRand.
ATTENTION
DIMPORTANTES INFORMATIONS DE SÉCURITÉ SONT JOINTES.
LIRE CE MANUEL AVANT DUTILISER LOUTIL.
LEMPLOYEUR EST TENU DE COMMUNIQUER LES INFORMATIONS
DE CE MANUEL AUX EMPLOYÉS UTILISANT CET OUTIL.
LE NON RESPECT DES AVERTISSEMENTS SUIVANTS PEUT CAUSER DES BLESSURES.
MISE EN SERVICE DE LOUTIL
S Toujours exploiter, inspecter et entretenir cet outil
conformément au Code de sécurité des outils
pneumatiques portatifs de lAmerican National
Standards Institute (ANSI B186.1).
Pour la sécurité, les performances optimales et la
durabilité maximale des pièces, cet outil doit être
connecté à une alimentation dair comprimé de
6,2 bar (620 kPa) maximum à lentrée, avec un
flexible de 13 mm de diamètre intérieur.
Couper toujours lalimentation dair comprimé et
débrancher le flexible dalimentation avant dinstaller,
déposer ou ajuster tout accessoire sur cet outil, ou
dentreprendre une opération dentretien quelconque
sur loutil.
Ne pas utiliser des flexibles ou des raccords
endommagés, effilochés ou détériorés.
Sassurer que tous les flexibles et les raccords sont
correctement dimensionnés et bien serrés. Voir Plan
TPD9051 pour un exemple type dagencement des
tuyauteries.
Utiliser toujours de lair sec et propre à une pression
maximum de 6,2 bar (620 kPa). La poussière, les
fumées corrosives et/ou une humidité excessive
peuvent endommager le moteur dun outil
pneumatique.
Ne jamais lubrifier les outils avec des liquides
inflammables ou volatiles tels que le kérosène, le
gasoil ou le carburant daviation.
Ne retirer aucune étiquette. Remplacer toute étiquette
endommagée.
UTILISATION DE LOUTIL
Porter toujours des lunettes de protection pendant
lutilisation et lentretien de cet outil.
Porter toujours une protection acoustique pendant
lutilisation de cet outil.
Tenir les mains, les vêtements flous et les cheveux
longs, éloignés de lextrémité rotative de loutil.
Prévoir, et ne pas oublier, que tout outil motorisé est
susceptible d’à–coups brusques lors de sa mise en
marche et pendant son utilisation.
Garder une position équilibrée et ferme. Ne pas se
pencher trop en avant pendant lutilisation de cet
outil. Des couples de réaction élevés peuvent se
produire à, ou en dessous, de la pression dair
recommandée.
La rotation des accessoires de loutil peut continuer
pendant un certain temps après le relâchement de la
gâchette.
Les outils pneumatiques peuvent vibrer pendant
lexploitation. Les vibrations, les mouvements
répétitifs et les positions inconfortables peuvent
causer des douleurs dans les mains et les bras.
Nutiliser plus doutils en cas dinconfort, de
picotements ou de douleurs. Consulter un médecin
avant de recommencer à utiliser loutil.
Utiliser les accessoires recommandés par
Ingersoll-Rand.
Nutiliser que les douilles et les accessoires pour clés à
chocs. Ne pas utiliser les douilles et accessoires
(chromés) de clés manuelles.
Cet outil nest pas conçu pour fonctionner dans des
atmosphères explosives.
Cet outil nest pas isolé contre les chocs électriques.
NOTE
Lutilisation de rechanges autres que les pièces dorigine IngersollRand peut causer des risques dinsécurité, réduire les
performances de loutil et augmenter lentretien, et peut annuler toutes les garanties.
Les réparations ne doivent être effectuées que par des réparateurs qualifiés autorisés. Consultez votre Centre de Service
IngersollRand le plus proche.
F
5
SIGNIFICATION DES ÉTIQUETTES D’AVERTISSEMENT
ATTENTION
LE NON RESPECT DES AVERTISSEMENTS SUIVANTS PEUT CAUSER DES BLESSURES.
Porter toujours des lunettes
de protection pendant
lutilisation et lentretien de
cet outil.
ATTENTION ATTENTION
Porter toujours une
protection acoustique
pendant lutilisation de cet
outil.
Les outils pneumatiques
peuvent vibrer pendant
lexploitation. Les vibrations,
les mouvements répétitifs et les
positions inconfortables
peuvent causer des douleurs
dans les mains et les bras.
Nutiliser plus doutils en cas
dinconfort, de picotements ou
de douleurs. Consulter un
médecin avant de recommencer
à utiliser loutil.
ATTENTION
Ne pas transporter loutil
par son flexible.
ATTENTION
ATTENTION
Garder une position équilibrée et
ferme. Ne pas se pencher trop
en avant pendant
lutilisation de cet outil.
ATTENTION
Utiliser de lair comprimé
à une pression maximum
de 6,2 bar (620 kPa).
90 psig
(6.2bar/620kPa)
Couper toujours lalimentation
dair comprimé et débrancher le
flexible dalimentation avant
dinstaller, déposer ou ajuster
tout accessoire sur cet outil, ou
dentreprendre une opération
dentretien quelconque sur lou-
til.
ATTENTION
ATTENTION
Ne pas utiliser des flexibles ou
des raccords endommagés,
effilochés ou détériorés.
RÉGLAGES
RÉGLAGE DU COUPLE
Pour ajuster le couple sur ces clés à impulsions à double
palette, procéder comme suit :
1. Déposer le bouchon du trou de réglage.
2. Tourner larbre dentraînement jusqu’à ce que la vis de
réglage de couple soit visible dans louverture.
3. A laide dune clé pour six pans creux de 1,5 mm,
tourner la vis dans le sens des aiguilles dune montre
pour augmenter le couple de serrage, ou dans le sens
inverse des aiguilles dune montre pour réduire le
couple. Ne pas tourner le bouchon dhuile.
NOTE
Effectuer tous les réglages finaux sur l’écrou à
serrer.
4. Remonter le bouchon dans le trou de réglage.
CHANGEMENT DU FLUIDE DU MÉCANISME
Le fluide du mécanisme dimpulsion est changé de la façon
suivante :
1. Déposer la gaine en caoutchouc du corps.
2. A laide dune clé pour six pans creux, déposer les
quatre vis du carter de marteau et les rondelles frein.
Retirer le carter de marteau du corps du moteur sur
larbre dentraînement. Déposer le joint du carter de
marteau.
3. Retirer le mécanisme assemblé du rotor.
4. A laide dune clé pour six pans creux de 2 mm,
tourner la vis de réglage de couple dans le sens des
aiguilles dune montre jusqu’à ce quelle vienne en
butée. Tourner la vis dans le sens inverse des aiguilles
dune montre jusqu’à ce quelle vienne en butée, ou
après six tours complets.
5. A laide dune clé pour six pans creux de 2,5 mm,
dévisser et déposer le bouchon dhuile. Déposer le joint
du bouchon dhuile et la bague dappui du joint.
6. Tout en tenant le trou du bouchon dhuile vers le bas
audessus dun récipient, tourner larbre
dentraînement pour purger le fluide contenu dans le
mécanisme.
7. Visser la clé en T fournie dans le nécessaire doutillage
(Réf. No. 1900P99) dans la butée de piston qui se
trouve à 180_ par rapport à la vis de réglage de couple
et tirer lensemble de butée vers la sortie et le
mécanisme jusqu’à ce quil sarrête.
8. A laide de la seringue et du fluide fourni dans le
nécessaire de fluide de remplacement (Réf.
No. EQ106SK400), remplir le mécanisme avec le
fluide fourni jusqu’à ce quil déborde du trou de
remplissage. Le Modèle 2400P nécessite 30 cm
3
de
fluide et le Modèle 3000P nécessite 43 cm
3
. Voir Plan
TPD1265.
NOTE
NE PAS UTILISER DAUTRE FLUIDE. La non
utilisation du fluide fourni pourrait causer
lendommagement de loutil, augmenter lentretien
et réduire les performances. Nutiliser que du fluide
propre dans ces outils.
6
RÉGLAGES
(Plan TPD1265)
9. Submerger louverture de remplissage dans le reste du
fluide et, à laide dune clé, tourner larbre
dentraînement pour purger tout lair du système.
10. Retirer le mécanisme du fluide et, à laide de la clé en
T, pousser lensemble de butée de piston lentement
vers le bas jusqu’à ce que le fluide déborde de
louverture de remplissage.
11. Visser le bouchon, équipé du joint et de son support,
dans le mécanisme et le serrer fermement.
12. A laide dune clé pour six pans creux de 2 mm,
tourner la vis de réglage de couple dans le sens des
aiguilles dune montre jusqu’à ce quelle vienne en
butée. Cest la position de couple maximum.
13. Essuyer lextérieur du mécanisme pour le sécher et
déposer le bouchon de la chambre dhuile. A laide de
la seringue, retirer 0,5 cm
3
de fluide sur le modèle
2400P et 1 cm
3
sur le modèle 3000P.
14. Remonter le bouchon de la chambre dhuile et le serrer
à un couple de 2,3 à 2,8 Nm.
15. Placer une nouvelle garniture de carter de marteau sur
le corps de moteur et installer le mécanisme assemblé
sur larbre du rotor.
16. Placer le couvercle de carter de marteau sur larbre
dentraînement et contre le corps et son joint. Monter
les quatre vis à six pans creux du carter de marteau et
les rondelles frein. Serrer chaque vis à un couple de
5,1 à 5,6 Nm.
17. Monter la gaine en caoutchouc sur loutil.
MISE EN SERVICE DE LOUTIL
LUBRIFICATION
IngersollRand No.50 IngersollRand No. 67
Fluide IngersollRand
Référence EQ106S4001
Utiliser toujours un lubrificateur avec ces outils. Nous
recommandons lemploi du filtrerégulateurlubrificateur
suivant :
É. U. C1803FKG028
Tous les 20 000 cycles, ou en fonction de lexpérience,
vider et remplir lensemble de mécanisme dimpulsion
conformément aux instructions du manuel en utilisant le
nécessaire de fluide de remplacement (Réf. No.
EQ106SK400). Lubrifier lentraîneur hexagonal et larbre
de sortie avant lassemblage.
TUYAUTERIE PRINCIPALE
AU MOINS 3 FOIS LA DIMEN-
SION DE L’ADMISSION D’AIR
DE L’OUTIL
VERS LE
RÉSEAU D’AIR
COMPRIMÉ
VERS
L’OUTIL
PNEU-
MATIQUE
LUBRIFICATEUR
RÉGULATEUR
FILTRE
LIGNE SECONDAIRE AU
MOINS 2 FOIS LA DIMEN-
SION DE L’ADMISSION
D’AIR DE L’OUTIL
VIDANGER
RÉGULIÈREMENT
COMPRESSEUR
(Plan TPD9051)
Toda comunicación se deberá dirigir a la oficina o
al distribuidor IngersollRand más próximo.
IngersollRand Company 2000
Impreso en Japón
MANUAL DE FUNCIONAMIENTO Y MANTENIMIENTO
PARA LLAVES DE IMPULSO DE DOBLE PALETA
MODELOS 2400P Y 3000P
NOTA
Las llaves de impulso modelos 2400P y 3000P está diseñadas para operaciones de ensamblaje
que requieran alta velocidad de atornillado con un par consistente y reducida reacción de par.
IngersollRand no aceptará responsabilidad alguna por la modificación de las herramientas
efectuada por el cliente para las aplicaciones que no hayan sido consultadas con
IngersollRand.
AVISO
SE ADJUNTA INFORMACIÓN IMPORTANTE DE SEGURIDAD.
LEA ESTE MANUAL ANTES DE UTILIZAR LA HERRAMIENTA.
ES RESPONSABILIDAD DE LA EMPRESA ASEGURARSE DE QUE EL OPERARIO
ESTÉ AL TANTO DE LA INFORMACIÓN QUE CONTIENE ESTE MANUAL.
EL HACER CASO OMISO DE LOS AVISOS SIGUIENTES PODRÍA OCASIONAR LESIONES.
PARA PONER LA HERRAMIENTA EN SERVICIO
S Utilice, examine y mantenga siempre esta
herramienta conforme al código de seguridad para
herramientas neumáticas portátiles de la American
National Standards Institute (ANSI B186.1).
Para mayor seguridad, rendimiento óptimo y larga
vida útil de las piezas, utilice esta herramienta a
una presión de aire máxima de 90 psig
(6,2 bar/620 kPa) con una manguera de suministro
de aire con diámetro interno de 13 mm.
Corte siempre el suministro de aire y desconecte la
manguera de suministro de aire antes de instalar,
desmontar o ajustar cualquier accesorio de esta
herramienta, o antes de realizar cualquier
operación de mantenimiento de la misma.
No utilice mangueras de aire y racores dañados,
desgastados o deteriorados.
Asegúrese de que todos los racores y mangueras
sean del tamaño correcto y estén bien apretados.
El Esq. TPD9051 muestra una disposición
característica de las tuberías.
Use siempre aire limpio y seco a una presión
máxima de 90 psig (6,2 bar/620 kPa). El polvo, los
gases corrosivos y el exceso de humedad pueden
estropear el motor de una herramienta neumática.
No lubrique las herramientas con líquidos
inflamables o volátiles tales como queroseno, gasoil
o combustible para motores a reacción.
No saque ninguna etiqueta. Sustituya toda etiqueta
dañada.
UTILIZACIÓN DE LA HERRAMIENTA
Use siempre protección ocular cuando utilice esta
herramienta o realice operaciones de
mantenimiento en la misma.
Use siempre protección para los oídos cuando
utilice esta herramienta.
Mantenga las manos, la ropa suelta y el cabello
largo alejados del extremo giratorio de la
herramienta.
Anticipe y esté atento a los cambios repentinos en el
movimiento durante la puesta en marcha y
utilización de toda herramienta motorizada.
Mantenga una postura del cuerpo equilibrada y
firme. No estire demasiado los brazos al manejar la
herramienta. Pueden darse elevados pares de
reacción a la presión de aire recomendada, e incluso
a presiones inferiores.
El eje de la herramienta puede seguir girando
brevemente después de haberse soltado el mando.
Las herramientas neumáticas pueden vibrar
durante el uso. La vibración, los movimientos
repetitivos o las posiciones incómodas pueden
dañarle los brazos y manos. En caso de
incomodidad, sensación de hormigueo o dolor, deje
de usar la herramienta. Consulte con el médico
antes de volver a utilizarla.
Utilice únicamente los accesorios IngersollRand
recomendados.
Utilice únicamente bocas y accesorios para llaves de
impacto. No utilice bocas o accesorios manuales
(cromados).
Esta herramienta no ha sido diseñada para trabajar
en ambientes explosivos.
Esta herramienta no está aislada contra descargas
eléctricas.
NOTA
El uso de piezas de recambio que no sean las auténticas piezas IngersollRand puede poner en peligro la seguridad, reducir
el rendimiento de la herramienta y aumentar los cuidados de mantenimiento necesarios, así como invalidar toda garantía.
Las reparaciones sólo se deben encomendar a personal debidamente cualificado y autorizado. Consulte con el centro de
servicio autorizado IngersollRand más próximo.
E
8
ETIQUETAS DE AVISO
AVISO
EL HACER CASO OMISO DE LOS AVISOS SIGUIENTES PODRÍA OCASIONAR
LESIONES.
ADVERTENCIA
Las herramientas neumáticas
pueden vibrar durante el uso.
La vibración, los movimientos
repetitivos o las posiciones
incómodas podrían dañarle los
brazos y las manos. En caso
de incomodidad, sensación de
hormigueo o dolor, dejar de
usar la herramienta. Consultar
al médico antes de volver a uti-
lizarla.
No coger la herramienta
por la manguera para le-
vantarla.
ADVERTENCIA
Mantener una postura del cuerpo
equilibrada y firme. No estirar de-
masiado los brazos al manejar la
herramienta.
Manejar la herramienta a una
presión de aire máxima de 90
psig (6,2 bar/620 kPa).
90 psig
(6.2bar/620kPa)
Cortar siempre el suministro
de aire y desconectar la man-
guera de suministro de aire
antes de instalar, retirar o ajus-
tar cualquier accesorio de esta
herramienta, o antes de realizar
cualquier operación de man-
tenimiento de la misma.
No utilizar mangueras de aire
y accesorios dañados, des-
gastados ni deteriorados.
ADVERTENCIA
ADVERTENCIA
ADVERTENCIA
ADVERTENCIA
ADVERTENCIA
ADVERTENCIA
Use siempre protección ocular
cuando utilice esta herramienta
o realice operaciones de
mantenimiento en la misma.
Use siempre protección para
los oídos cuando utilice esta
herramienta.
AJUSTES
AJUSTE DE PAR
Para ajustar el par de estas llaves de impulso de doble
paleta, proceda como sigue:
1. Saque el tapón del orificio de ajuste.
2. Gire el eje de accionamiento hasta que el tornillo de
ajuste de par sea visible a través de dicho orificio.
3. Con una llave hexagonal de 1,5 mm, gire el tornillo de
ajuste de par hacia la derecha para incrementar el par y
hacia la izquierda para disminuirlo. No gire el tapón
del aceite.
NOTA
Haga todos los ajustes finales trabajando.
4. Vuelva a poner en su sitio el tapón del orificio de
ajuste.
CAMBIO DEL LÍQUIDO DEL MECANISMO
Para cambiar el líquido del mecanismo de impulso, proceda
como sigue:
1. Saque la funda de la carcasa de caucho.
2. Utilizando una llave hexagonal, saque los cuatro
tornillos de la caja de mazas y las arandelas de
seguridad. Levante la caja de mazas y sáquela de la
carcasa del motor por encima del eje de accionamiento.
Saque la junta obturadora de la caja de mazas.
3. Levante el mecanismo ensamblado y sáquelo del rotor.
4. Con una llave hexagonal de 2 mm, gire el tornillo de
ajuste de par hacia la derecha hasta que se pare. Gire el
tornillo hacia la izquierda hasta que se pare o dé seis
vueltas completas.
5. Con una llave hexagonal de 2,5 mm, desenrosque y
saque el tapón del aceite. Saque el retén del tapón del
aceite y el soporte de dicho retén.
6. Con el orificio del tapón del aceite apuntando hacia
abajo sobre un contenedor, gire el eje de accionamiento
para purgar el líquido del mecanismo.
7. Enrosque la llave en T que se incluye en la caja de
herramientas (Ref. Nº 1900P99)) en el conjunto del
tope del pistón que se encuentra a 180 grados del
tornillo de ajuste de par, y tire de dicho conjunto hacia
el extremo de salida del mecanismo hasta que se pare.
8. Con la jeringuilla y el líquido del juego de cambio de
líquido (Ref. Nº EQ106SK400), llene el mecanismo
con el líquido suministrado en dicho equipo hasta que
el líquido se salga del orificio de llenado. El modelo
2400P requerirá 30 cc de líquido, y el modelo 3000P,
43 cc. Vea Esq. TPD1265.
NOTA
NO SUSTITUYA CON NINGÚN OTRO
LÍQUIDO. Si no se usa el líquido de mecanismo
impulsor suministrado, se podría dañar la
herramienta, incrementar su mantenimiento y
disminuir su rendimiento. Use solamente líquido
limpio con estas herramientas.
9
AJUSTES
(Esq. TPD1265)
9. Sumerja el orificio de llenado en el resto del líquido y,
utilizando una llave, gire el eje de accionamiento para
purgar el aire que pudiera quedar en el sistema.
10. Saque el mecanismo del líquido y utilice la llave en
T para empujar lentamente el conjunto de tope del
pistón hacia abajo hasta que el líquido se salga del
orificio de llenado.
11. Enrosque el tapón del aceite con el retén del tapón de
aceite y el soporte del retén en el mecanismo hasta que
quede bien ajustado.
12. Con una llave hexagonal de 2 mm, gire el tornillo de
ajuste de par hacia la derecha hasta que se pare. Ésta es
la posición de máximo par.
13. Limpie la parte de fuera del mecanismo y séquelo, y
saque el tapón de la cámara de aceite. Utilizando la
jeringuilla, saque 0,5 cc de líquido de los modelos
2400P, y 1,0 cc de los modelos 3000P.
14. Instale el tapón de la cámara de aceite y apriételo entre
20 y 25 pulg.lb (2,3 a 2,8 Nm) de par.
15. Coloque una junta obturadora de la caja de mazas
nueva en la carcasa del motor e instale el mecanismo
ensamblado en el eje rotor.
16. Coloque la cubierta de la caja de mazas sobre el eje de
accionamiento y contra la carcasa y la junta
obturadora. Instale los cuatro tornillos de la caja de
mazas y las arandelas de seguridad. Apriete cada
tornillo entre 45 y 50 pulglb ( 5,1 y 5,6 Nm) de par.
17. Instale la funda de la carcasa de caucho en la
herramienta.
PARA PONER LA HERRAMIENTA EN SERVICIO
LUBRICACIÓN
IngersollRand Nº 50 IngersollRand Nº 67
Líquido IngersollRand
Nº EQ106S4001
Utilice siempre un lubricador de aire comprimido con estas
herramientas. Recomendamos utilizar el siguiente conjunto
de filtrolubricadorregulador:
EE.UU. C1103G00
Después de cada 20 000 ciclos, o según indique la
experiencia, drene y vuelva a llenar el conjunto de
accionamiento del mecanismo impulsor tal y como se
indica en este manual, utilizando el juego de cambio de
líquido (Ref. Nº EQ106SK400). Lubrique el eje de salida
y el de accionamiento hexagonal antes del montaje.
TUBERÍAS PRINCIPALES 3
VECES EL TAMAÑO DE
ENTRADA DE HERRAMIENTA
NEUMÁTICA
AL SISTEMA
NEUMÁTICO
A LA
HERRA
MIENTA
NEUMÁTICA
LUBRICADOR
REGULADOR
FILTRO
TUBERÍA DE RAMAL
2 VECES EL TAMAÑO
DE ENTRADA DE
HERRAMIENTA
NEUMÁTICA
PURGAR
PERIÓDICAMENTE
COMPRESOR
(Esq. TPD9051)
Envie Todos os Comunicados Para o Distribuidor
ou Escritório da IngersollRand Mais Próximo.
IngersollRand Company 2000
Fabricado no Japão
MANUAL DE FUNCIONAMENTO E MANUTENÇÃO
PARA FERRAMENTAS
PNEUMÁTICAS DE IMPULSÃO DE LÂMINAS DUPLAS
MODELOS 2400P E 3000P
AVISO
As Ferramentas Pneumáticas de Impulsão Modelos 2400P e 3000P são concebidas para
operações de montagem que exijam velocidade de aperto elevada com torque exercido
consistente e reacção de torque reduzida.
A IngersollRand não é responsável por modificações feitas pelo cliente em ferramentas nas quais a
IngersollRand não tenha sido consultada.
ADVERTÊNCIA
INFORMAÇÃO DE SEGURANÇA IMPORTANTE EM ANEXO.
LEIA ESTE MANUAL ANTES DE OPERAR A FERRAMENTA.
É DA RESPONSABILIDADE DO EMPREGADOR COLOCAR A INFORMAÇÃO
DESTE MANUAL NAS MÃOS DO OPERADOR.
O NÃO CUMPRIMENTO DAS SEGUINTES ADVERTÊNCIAS PODE
RESULTAR EM FERIMENTOS.
COLOCANDO A FERRAMENTA
EM FUNCIONAMENTO
S Sempre opere, inspeccione e mantenha esta
ferramenta de acordo com o Código de Segurança
do Instituto Americano de Padrões Nacionais para
Ferramentas Pneumáticas Portáteis (ANSI B186.1).
Para segurança, máximo desempenho e máxima
durabilidade das peças, opere esta ferramenta com
uma pressão de ar máxima de 6,2 bar/620 kPa
(90 psig) na entrada da mangueira de alimentação
de ar com diâmetro interno de 13 mm (1/2).
Desligue sempre a alimentação de ar e desconecte a
mangueira de alimentação de ar antes de instalar,
remover ou ajustar qualquer acessório nesta
ferramenta, ou antes de executar qualquer serviço de
manutenção nesta ferramenta.
Não use mangueiras de ar ou adaptadores danificados,
gastos ou deteriorados.
Certifiquese de que todas as mangueiras e
adaptadores sejam do tamanho correcto e estejam
apertados com firmeza. Veja o Desenho TPD9051
para um arranjo típico de tubagem.
Use sempre ar seco e limpo com pressão máxima de
6,2 bar/620 kPa (90 psig). Pó, fumos corrosivos e/ou
humidade excessiva podem arruinar o motor de
uma ferramenta pneumática.
Não lubrifique as ferramentas com líquidos
inflamáveis ou voláteis tais como querosene, diesel ou
combustível de jactos.
Não remova nenhum rótulo. Reponha qualquer rótulo
danificado.
USANDO A FERRAMENTA
Use sempre óculos de protecção quando estiver
operando ou executando serviço de manutenção nesta
ferramenta.
Use sempre protecção contra ruído ao operar esta
ferramenta.
Mantenha as mãos, partes do vestuário soltas e cabelos
compridos afastados da extremidade em rotação.
Antecipe e esteja alerta a mudanças repentinas no
movimento quando ligar e operar qualquer
ferramenta motorizada.
Mantenha a posição do corpo equilibrada e firme. Não
exagere quando operar esta ferramenta. Torques de
reacção elevados podem ocorrer na ou abaixo da
pressão de ar recomendada.
O eixo da ferramenta pode continuar a girar
brevemente após a pressão ter sido aliviada.
Ferramentas accionadas pneumáticamente podem
vibrar em uso. Vibração, movimentos repetitivos ou
posições desconfortáveis podem ser prejudiciais às
mãos e aos braços. Pare de usar a ferramenta caso
ocorra algum desconforto, sensação de formigueiro ou
dor. Procure assistência médica antes de retornar ao
trabalho.
Use acessórios recomendados pela IngersollRand.
Use somente soquetes e acessórios de impacto. Não use
soquetes ou acessórios de mão (cromo).
Esta Ferramenta não foi concebida para trabalhos em
atmosferas explosivas.
Esta Ferramenta não está isolada contra choques
eléctricos.
AVISO
O uso de peças de substituição que não sejam genuinamente da IngersollRand podem resultar em riscos de segurança,
diminuição do desempenho da ferramenta, aumento da necessidade de manutenção e pode invalidar todas as garantias.
As reparações devem ser feitas somente por pessoal treinado autorizado. Consulte o Centro de Serviços da IngersollRand
mais próximo.
P
11
IDENTIFICAÇÃO DO RÓTULO DE ADVERTÊNCIA
ADVERTÊNCIA
O NÃO CUMPRIMENTO DAS SEGUINTES ADVERTÊNCIAS PODE
RESULTAR EM FERIMENTOS.
Use sempre óculos de
protecção quando estiver
operando ou executando algum
serviço de manutenção nesta
ferramenta.
ADVERTÊNCIA
Use sempre protecção contra o
ruído ao operar esta ferramenta.
Desligue sempre a alimentação
de ar e desconecte a mangueira
de alimentação de ar antes de
instalar, remover ou ajustar
qualquer acessório nesta
ferramenta, ou antes de
executar algum serviço de
manutenção nesta ferramenta.
Ferramentas accionadas
pneumáticamente podem vibrar
em uso. Vibração, movimentos
repetitivos ou posições
desconfortáveis podem ser
prejudiciais às mãos e aos
braços. Pare de usar a
ferramenta caso ocorra algum
desconforto, sensação de
formigueiro ou dor. Procure
assistência médica antes de
retornar ao trabalho.
Não carregue a ferramenta
segurando na mangueira.
ADVERTÊNCIA
Não use mangueiras de ar ou
adaptadores danificados,
gastos ou deteriorados.
Mantenha a posição do corpo
equilibrada e firme. Não
exagere quando operar esta
ferramenta. Torques de reacção
elevados podem ocorrer sob a
pressão de ar recomendada.
Opere com pressão do ar Máxima
de 90100 psig (6,26,9 bar).
90 psig
(6.2bar/620kPa)
ADVERTÊNCIA
ADVERTÊNCIA
ADVERTÊNCIA
ADVERTÊNCIA
ADVERTÊNCIA
ADVERTÊNCIA
AJUSTES
AJUSTE DE TORQUE
Para ajustar o torque nestas Ferramentas Pneumáticas de
Impulso de Lâminas Duplas, proceda da seguinte maneira:
1. Remova o Bujão do Furo de Ajuste.
2. Gire o Eixo de Comando até o Parafuso de Ajuste de
Torque estar visível na abertura.
3. Usando uma chave Allen de 1,5 mm, gire o Parafuso
de Ajuste no sentido horário para aumentar o torque de
saída e no sentido antihorário para diminuir o torque
de saída. Não gire o Bujão de Óleo.
AVISO
Faça todos os ajustes finais no serviço.
4. Reponha o Bujão do Furo de Ajuste.
MUDANDO O FLUIDO DO MECANISMO
Para mudar o Fluído do Mecanismo no Mecanismo de
Impulso, proceda da seguinte maneira:
1. Remova o Calço do Corpo de Borracha.
2. Usando uma chave Allen, remova os três Parafusos dos
Tampos da Caixa do Martelo e Anilhas de Trava. Erga
a Caixa do Martelo para fora do Corpo do Motor sobre
o Eixo de Comando. Remova a Junta da Culatra da
Caixa do Martelo.
3. Erga o mecanismo montado do motor.
4. Usando uma chave Allen de 2 mm gire o Parafuso de
Ajuste de Torque no sentido horário até que o Parafuso
pare. Gire o Parafuso no sentido contrário ao dos
ponteiros do relógio até que ele pare ou complete 6
revoluções.
5. Usando uma chave Allen de 2,5 mm, desparafuse e
remova o Bujão de Óleo. Remova o Lacre do Bujão do
Óleo e o Suporte do Lacre do Bujão de Óleo.
6. Com a abertura do bujão de óleo para baixo sobre um
recipiente, gire o Eixo de Comando para expelir o
fluido do mecanismo.
7. Rosqueie a Chave em T incluída no Kit de
Ferramenta (Número 1900A99) no Conjunto de
Paragem do Pistão que está a 180 graus do Parafuso de
Ajuste de Torque e puxe o Conjunto de Paragem em
direção à saída do mecanismo até que ele pare.
8. Usando a seringa e fluído do Kit de Reposição de
Fluído (Número de Pedido EQ106SK400), encha o
mecanismo com o fluído fornecido no Kit até que o
fluído transborde do orifício de enchimento. O Modelo
2400P necessitará 30 cc de fluído, o Modelo 3000P, 43
cc. Veja o Desenho TPD1265.
AVISO
NÃO SUBSTITUA POR QUALQUER
OUTRO FLUÍDO.
Caso o fluido fornecido não for usado danos podem
ocorrer à ferramenta, aumento da manutenção e
diminuição do desempenho. Use somente fluido
limpo nestas ferramentas.
12
AJUSTES
(Desenho TPD1265)
9. A abertura de enchimento deve ser submersa no
restante do fluido, e usando uma chave, gire o Eixo do
Comando para expelir qualquer ar remanescente do
sistema.
10. Remova o mecanismo do fluido e use uma Chave em
T para empurrar o Conjunto de Paragem do Pistão
lentamente para baixo até que o fluido flua da abertura
de enchimento.
11. Rosqueie o Bujão de Óleo com o Lacre do Bujão de
Óleo no mecanismo até que ele esteja apertado.
12. Usando uma chave Allen de 2 mm, gire o Parafuso de
Ajuste de Torque no sentido horário até o Parafuso
parar. Esta é a posição de aperto máximo.
13. Limpe a parte externa do mecanismo a seco e limpe e
remova o Bujão da Câmara de Óleo. Usando uma
seringa, retire 0,50 cc de fluido do modelo 2400P e
1,0 cc do modelo 3000P.
14. Instale o Bujão da Câmara de Óleo e aperteo com 2,3
a 2,8 Nm (20 a 25 pollb).
15. Posicione a Junta da Culatra da Caixa do Martelo nova
no Corpo do Motor e instale o mecanismo montado no
eixo do rotor.
16. Coloque a Capa da Caixa do Martelo sobre o Eixo de
Comando contra o Corpo e o Junta da Culatra. Instale
os três Parafusos do Tampo da Caixa do Martelo e
Anilhas de Trava. Aperte cada Parafuso com um torque
de 5,1 e 5,6 Nm (45 e 50 pollb).
17. Instale o Calço do Corpo de Borracha na ferramenta.
COLOCANDO A FERRAMENTA EM FUNCIONAMENTO
LUBRIFICAÇÃO
IngersollRand No. 50 IngersollRand No. 67
Fluído IngersollRand
Número de Pedido
No. EQ106S4001
Use sempre um lubrificador de ar de linha com estas
ferramentas. Nós recomendamos a seguinte Unidade
FiltroLubrificadorRegulador:
Para os E.U.A. No. C1803FKG028
Depois de cada 20 000 ciclos, ou como a experiência
indicar, drene e encha o Conjunto do Comando da Unidade
de Impulso como instruído neste manual usando o Kit de
Reposição de Fluído (Número de Pedido EQ106SK400).
Lubrifique o comando hexagonal e o eixo de saída antes de
montar.
LINHAS PRINCIPAIS 3 VEZES O TAMANHO DA
ENTRADA DA FERRAMENTA PNEUMÁTICA
PARA
SISTEMA DE AR
PARA
FERRAMENTA
PNEUMÁTICA
LUBRIFICADOR
REGULADOR
FILTRO
LINHA RAMIFICADA
2 VEZES O TAMANHO
DA ENTRADA DA
FERRAMENTA
PNEUMÁTICA
DRENE
REGULARMENTE
COMPRESSOR
(Desenho TPD9051)
MAINTENANCE SECTION
13
(Dwg. TPA1342)
MAINTENANCE SECTION
14
PART NUMBER FOR ORDERING
2400P 3000P
Motor Housing Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PA40 3000PA40
1 Motor Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P40 3000P40
2 Reverse Lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000P328 3000P328
3 Reverse Lever Retaining Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000P152 3000P152
4 Reverse Valve Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P330 2400P330
5 Reverse Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P329 2400P329
6 Reverse Valve Detent Ball . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500P333 500P333
7 Reverse Valve Detent Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P51 1900P51
8 Reverse Valve Retainer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1410P303 1410P303
9 Suspension Hole Liner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100P232 1100P232
10 Throttle Bushing Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ112PA503 EQ112PA503
11 Throttle Bushing Seal (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106P283 EQ106P283
12 Throttle Valve Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ112PA304 EQ112PA304
13 Throttle Valve Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ112P159 EQ112P159
14 Valve Retaining Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106P303 EQ106P303
15 Throttle Rod Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ112PA302 EQ112PA302
16 Throttle Rod Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106P288 EQ106P288
17 Trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106P93 EQ106P93
18 Trigger Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106P265 EQ106P265
19 Throttle Retaining Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180PQ120 180PQ120
20 Inlet Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106S565 EQ106S565
21 Exhaust Deflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PA23 2400PA23
Motor Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PA53 3000PA53
Rear End Plate Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PA12 3000PA12
22 Rear End Plate Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PB12 EQ230PA12
23 End Plate Alignment Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P152 EQ230P99
24 Rear Rotor Bearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R38P606 EQ230P24
25 Cylinder Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PA3 3000PA3
26 Cylinder Alignment Pin (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P152 3000P152
27 Rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P53 EQ230P53
28 Vane Packet (set of 6 Vanes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P426 EQ230P426
29 Front End Plate Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PA11 3000PA11
30 Front Rotor Bearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P22 2400P22
MAINTENANCE SECTION
15
PART NUMBER FOR ORDERING
2400P 3000P
31 Motor Case Cover Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PA202 3000PA202
32 Suspension Hole Liner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100P232 1100P232
33 Motor Case Cover Gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P739 3000P739
34 Motor Case Cover Screw (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P277 3000P638
35 Cover Screw Lock Washer (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ112P58 EQ112P58
Hammer Case Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PA727 3000PA727
36 Hammer Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P727 3000P727
37 Hammer Case Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ110P641 3000P641
38 Adjustment Hole Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500P95 500P95
39 Hammer Case Gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P740 3000P740
40 Hammer Case Cap Screw (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P277 3000P638
41 Cap Screw Lock Washer (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ112P58 EQ112P58
42 Dead Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ––– EQ230PA48
43 Rubber Housing Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P2 3000P2
44 Nameplate
for models ending in EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –––––– 3000PEU301
for all other models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P301 3000P301
* Forward Rotation Label (for models ending in EU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –––––– 7802REUF99
* Reverse Rotation Label (for models ending in EU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –––––– 7802REUR99
45 Nameplate Screw (2 for 2400P; 4 for 3000P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106S322 EQ106S322
46 Warning Label
for models ending in EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –––––– EU99
for all other models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WARNING299 WARNING299
47 Oil Daily Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500P69 500P69
48 Two Speed Trigger Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180PQ68 180PQ68
* Motor Tuneup Kit (includes illustrated items 24, 28, 30 and 33) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PK500 3000PK500
* Not illustrated.
16
MAINTENANCE SECTION
PART NUMBER FOR ORDERING
2400P 3000P
Impulse Unit Drive Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400PA200 3000PA200
49 Liner Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P240 EQ230P240
Front Cover Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900PA211 3000PA211
50 Front Liner Cover Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . 1900PB211 3000PB211
51 Torque Adjustment Screw . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P230 1900P230
52 Adjustment Screw Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P288 2400P288
53 Alignment Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P120 EQ230P232
54 Oil Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ230P277 EQ230P277
55 Oil Plug Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ208S238 EQ208S238
56 Oil Plug Seal Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ230P229 EQ230P229
57 Drive Shaft Oring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ110P271 EQ230P271
58 Seal Backup Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ110P272 EQ230P272
59 Front Liner Cover Piston Seal (2) . . . . . . . . . . . . . . . . . . . . . . . . . 2400P237 3000P236
60 Liner Housing Seal (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P238 3000P238
Drive Shaft Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900PA626 –––
61 Drive Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P626 3000P626
62 Socket Retaining Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804716 –––
63 Retaining Pin Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5HUD718 –––
64 Drive Shaft Blade (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P220 EQ230P220
65 Blade Spring (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P219 EQ230P219
66 Liner Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900PA203 3000PA203
67 Liner Alignment Pin (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P298 EQ230P298
68 Torque Valve Piston . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P222 EQ230P222
Piston Stop Assembly (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900PA255 EQ230PA255
69 Piston Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P255 EQ230P255
70 Piston Stop Seal (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ104S50 EQ230P288
71 Piston Stop Assist Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P219 1900P219
72 Rear Liner Cover Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P238 3000P237
73 Rear Liner Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P212 EQ230P212
74 Housing Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ112P207 EQ230P207
* Fluid Replacement Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106SK400 EQ106SK400
* Replacement Fluid (4 oz.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106S4001 EQ106S4001
* Mechanism Tuneup Kit (includes illustrated
items 55, 56, 57, 58, 59 [2], 60 [2], 70 [2] and 72) . . . . . . . . . . . . . . . 1900PK600 –––
* Mechanism Tuneup Kit (includes illustrated
items 39, 55, 56, 57, 58, 59 [2], 60 [2], 65 [2], 70 [2], 71 and 72) . . . ––– 3000PK600A
* Tool Kit (includes all the specialized tooling required to repair
these tools and consists of a Spanner Plug, Threaded Tee Wrench,
Oring Installer and a pressing fixture that has a Disassembly
Arbor and Pressing Sleeve) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P99 1900P99
* Not illustrated.
17
MAINTENANCE SECTION
CHANGING THE MECHANISM FLUID
To change the Mechanism Fluid in the Impulse
Mechanism, proceed as follows:
1. Remove the Rubber Housing Boot (43).
2. Using a hex wrench, remove the four Hammer Case
Cap Screws (40) and Lock Washers (41). Lift the
Hammer Case (36) off the Motor Housing (1) over the
Drive Shaft. Remove the Hammer Case Gasket (39).
3. Lift the assembled mechanism off the Rotor (27).
4. Using a 2 mm hex wrench, rotate the Torque
Adjustment Screw (51) clockwise until the Screw
stops. Rotate the Screw counterclockwise until it
stops or makes six complete revolutions.
5. Using a 2.5 mm hex wrench, unscrew and remove the
Oil Plug (54). Remove the Oil Plug Seal (55) and
Oil Plug Seal Support (56).
6. With the oil plug opening downward over a container,
rotate the Drive Shaft to purge the fluid from the
mechanism.
7. Thread the Tee Wrench included with the Tool Kit
(Part No. 1900P99) into the Piston Stop Assembly
(69) that is 180 degrees from the Torque Adjustment
Screw and pull the Stop Assembly toward the output
end of the mechanism until it stops.
8. Using the syringe and fluid from the Fluid
Replacement Kit (Part No. EQ106SK400), fill the
mechanism with the fluid furnished in the Kit until
the fluid overflows the fill hole. Model 2400P will
require 30 cc of fluid, Model 3000P, 43 cc.
(Refer to Dwg. TPD1265)
DO NOT SUBSTITUTE ANY OTHER FLUID.
Failure to use the impulse mechanism fluid
provided could damage the tool, increase
maintenance and decrease performance. Use only
clean fluid in these tools.
(Dwg. TPD1265)
9. Submerge the fill opening in the remainder of the
fluid, and using a wrench, rotate the Drive Shaft to
purge any remaining air from the system.
10. Remove the mechanism from from the fluid and use
the Tee Wrench to push the Piston Stop Assembly
slowly downward until fluid flows from the fill
opening.
11. Thread the Oil Plug with the Oil Plug Seal and Seal
Support into the mechanism until it is snug.
12. Using a 2 mm hex wrench, turn the Torque
Adjustment Screw clockwise until it stops. This is the
maximum torque position.
13. Wipe the outside of the mechanism dry and clean and
remove the Oil Chamber Plug. Using the syringe,
withdraw 0.5 cc of fluid from 2400P models and 1.0
cc from 3000P models.
14. Install the Oil Chamber Plug and tighten it between
20 and 25 inlb (2.3 and 2.8 Nm) torque.
15. Position a new Hammer Case Gasket on the Motor
Housing and install the assembled mechanism on the
rotor shaft.
16. Place the Hammer Case Cover over the Drive Shaft
against the Housing and Gasket. Install the four
Hammer Case Cap Screws and Lock Washers.
Tighten each Screw between 45 an 50 inlb (5.1 and
5.6 Nm) torque.
17. Install the Rubber Housing Boot on the tool.
DISASSEMBLY
General Instructions
1. Do not disassemble the tool any further than
necessary to replace or repair damaged parts.
2. When grasping a tool or part in a vise, always use
leathercovered or coppercovered vise jaws to
protect the surface of the part and help prevent
distortion. This is particularly true of threaded
members and housings.
3. Do not remove any part which is a press fit in or on
an assembly unless the removal of that part is
necessary for repairs or replacement.
Disassembly of the Impulse Mechanism
1. Use a hooked wire to pull the Retaining Pin Spring
(63) out of the end of the Drive Shaft (61) and remove
the Socket Retaining Pin (62).
2. Remove the Rubber Housing Boot (43).
3. Using a hex wrench, remove the four Hammer Case
Cap Screws (40) and Lock Washers (41). Lift the
Hammer Case (36) off the Motor Housing (1) over the
Drive Shaft. Remove the Hammer Case Gasket (39).
4. Lift the assembled mechanism off the Rotor (27).
5. Grasp the flats of the Housing (49) in vise jaws with
the output end of the Drive Shaft downward.
18
MAINTENANCE SECTION
6. Insert the pins of the Spanner Plug from the No.
1900P99 Tool Kit into two holes in the Housing
Cap (74). Using a wrench on the plug, unscrew and
remove the Housing Cap from the Housing.
(Refer to Dwg. TPD1267.)
It may be necessary to cut the thread sealant
around the Housing Cap with a sharp knife before
attempting to remove the Cap.
(Dwg. TPD1267)
SPANNER PLUG
COUNTERCLOCKWISE TO LOOSEN
7. Stand the Disassembly Arbor from the Tool Kit, large
end downward, on a workbench or the table of an
arbor press. Insert the output end of the Drive Shaft
into the central opening and either tap the Housing
downward off the components or use the Pressing
Sleeve in the Kit to press the Housing downward off
the components. (Refer to Dwg. TPD1268.)
(Dwg. TPD1268)
PRESSING SLEEVE
TAP EDGE LIGHTLY WITH
BRASS HAMMER OR USE
PRESSING SLEEVE FROM
TOOL KIT
DISASSEMBLY ARBOR FROM
TOOL KIT
8. Disassemble the components of the mechanism in the
sequence shown in Drawing TPA1342 on Page 4.
Disassembly of the Motor
1. Grasp the Motor Housing (1) in vise jaws with the
Motor Case Cover Assembly (31) upward.
2. Using a hex wrench, remove the four Motor Case
Cover Screws (34) and Lock Washers (35).
3. Remove the Cover and Motor Case Cover Gasket (33)
from the Motor Housing.
4. Remove the Housing from the vise jaws and insert a
rod into the central opening in the output end of the
rotor shaft.
5. While holding the motor end of the Housing above a
piece of cardboard on the workbench, lightly tap the
rod to remove the Rear End Plate Assembly (22),
Rotor (27) and Vanes (28).
6. On the table of an arbor press, support the Rear End
Plate with blocks as close to the Rotor as possible and
press the Rotor out of the Rear End Plate and Rear
Rotor Bearing (24).
7. To remove the Rear Rotor Bearing from the Rear End
Plate, use a small drift or pin punch through the
central opening of the Rear End Plate to tap the
Bearing out of the End Plate. (Refer to Dwg.
TPD1271.)
Do not enlarge or damage the shaft hole in the End
Plate.
(Dwg. TPD1271)
8. Using a longer drift punch through the Cylinder (25),
tap the Front Rotor Bearing (30) out of the Front End
Plate Assembly (29) in the same manner.
Do not enlarge or damage the shaft hole in the End
Plate.
9. The Cylinder and Front End Plate are a shrink fit in
the Motor Housing and parts that can be damaged
during the heating process must be removed before
heating the Housing.
10. Press the Reverse Lever Pin (3) out of the Reverse
Lever (2) and pull the lever off the shaft of the
Reverse Valve (5).
11. Using snap ring pliers, remove the Reverse Valve
Retainer (8).
12. Grasp the shaft of the Reverse Valve with pliers, and
pull the Reverse Valve, Reverse Valve Detent Ball (6)
and Detent Spring (7) out of the Reverse Valve
Bushing (4). Be careful not to lose the Ball and
Spring.
13. Using a pin punch, tap the Throttle Retaining Pin (19)
out of the Handle.
19
MAINTENANCE SECTION
14. Grasp the Trigger (17) and pull the assembled throttle
out of the Motor Housing.
15. Using a pin punch and without damaging the Trigger,
remove the Trigger Pin (18).
16. Slide the Throttle Bushing Assembly (10) off the shaft
of the Throttle Rod Assembly (15).
17. Using a thin blade screwdriver, remove the Valve
Retaining Ring (14) and slide the Throttle Valve
Assembly (12) off the shaft of the Throttle Valve Rod.
18. Using an adjustable wrench, unscrew and remove
the Inlet Bushing (20) and Exhaust Deflector
Assembly (21).
19. Insert a threaded rod through the Cylinder and Front
End Plate and install a nut and washer on the end
plate end of the rod. Position the Rear End Plate on
the threaded rod against the Cylinder and clamp the
End Plates and Cylinder snug with another nut and
washer. Do not tighten the assembly excessively.
20. Using a heat induction coil or an oven, heat the
assembly and Housing until it is warm enough to pull
the assembly out the rear of the Motor Housing. Do
not apply enough heat to distort the Housing.
Take all precautions necessary to prevent being
burned by handling warm or hot parts.
ASSEMBLY
General Instructions
1. When grasping a tool or part in a vise, always use
leathercovered or coppercovered vise jaws to
protect the surface of the part and help prevent
distortion. This is particularly true of threaded
members and housings.
2. Always press on the inner ring of a balltype bearing
when installing the bearing on a shaft.
3. Always press on the outer ring of a balltype bearing
when pressing the bearing into a bearing recess.
4. Except for bearings and mechanism parts, always
clean every part and wipe every part with a thin film
of oil before installation.
5. Wipe a thin film of mechanism fluid on all internal
mechanism components before installing them in the
mechanism.
6. Apply a film of Oring lubricant to every Oring
before installation.
Assembly of the Motor
1. Using an arbor press and a piece of tubing that
contacts the outer ring of the bearings, press the Front
Rotor Bearing (30) into the Front End Plate (29) and
the Rear Rotor Bearing (24) into the Rear End Plate
(22). (Refer to Dwg. TPD1274.)
(Dwg. TPD1274)
TUBING
BEARING
END PLATE
2. Stand the Rotor (27) on the table of an arbor press. It
should be upright on a flat metal plate having a
clearance hole for the shaft. The shaft with the hex
must be upward.
3. Place a 0.001 (0.025 mm) shim on the upward
surface of the large portion of the rotor body. Using a
piece of tubing that contacts the inner ring of the
bearing, press the Front Rotor Bearing and Front End
Plate, End Plate leading, onto the shaft of the Rotor
until the End Plate contacts the shim. Remove the
shim. (Refer to Dwg. TPD1275.)
(Dwg. TPD1275)
PRESSING PLUG
FRONT ROTOR BEARING
ROTOR
PLATE WITH ROTOR
SHAFT CLEARANCE
FRONT END PLATE
0.001 (0.025 mm)
SHIM SPACE
4. Coat each Vane (28) with a thin film of oil and insert
a Vane into each of the rotor vane slots with the
straight edge of the Vane outward.
5. Install the Cylinder Assembly (25) over the Vanes and
Rotor making certain the Cylinder Alignment Pin (26)
enters the hole in the face of the Front End Plate.
6. Stand the assembly on an arbor press table so that the
rotor shaft on the front end plate end contacts the
table. Press the Rear End Plate Assembly, bearing end
trailing, onto the rotor shaft against the Cylinder.
Make certain the Cylinder Alignment Pin (26) enters
the hole in the face of the Rear End Plate.
7. Stand the assembly on a table with the Front End
Plate Assembly upward.
20
MAINTENANCE SECTION
8. Using an induction coil or oven, heat the Motor
Housing until the motor opening is large enough to be
placed over the Cylinder. At that time, install the
Housing over the Cylinder and Front End Plate
making sure the radial End Plate Alignment Pin (23)
in the Rear End Plate enters the notch in the Motor
Housing.
Take all precautions necessary to prevent being
burned by handling warm or hot parts.
9. Allow the assembly to cool and install the Motor Case
Cover Gasket (33) and Motor Case Cover (31).
10. Secure the Cover to the Housing by installing the four
Motor Case Cover Screws (34) and Lock Washers
(35). Tighten each Screw between 45 and 50 inlb
(5.1 and 5.6 Nm) torque.
11. Install the Exhaust Deflector (21) in the bottom of the
handle of the Motor Housing (1) and tighten it
between 20 and 25 ftlb (27 and 34 Nm) torque.
12. Thread the Inlet Bushing (20) into the bottom of the
handle of the Motor Housing and tighten it between
30 and 35 ftlb (40 and 47 Nm) torque.
13. Install the Throttle Rod Seal (16) in the groove on the
large hub of the Throttle Rod (15).
14. Install the Throttle Valve Seal (13) in the groove on
the large hub of the Throttle Valve (12).
15. Slide the Throttle Valve, Valve Seal end first, onto the
Throttle Valve Rod.
16. Secure the Throttle Valve Assembly by installing the
Valve Retaining Ring (14) in the small groove on the
Throttle Valve Rod.
17. Install the three Throttle Bushing Seals (11) in the
grooves on the Throttle Bushing (10).
18. Slide the Throttle Bushing Assembly onto the shaft of
the Throttle Valve Rod and position the Trigger (17)
on the same shaft. Install the Trigger Pin (18).
19. Insert the assembled Trigger into the Housing. Make
certain the widest end of the Trigger is nearest the
motor bore and the narrowest portion of the Throttle
Valve aligns with hole for the Throttle Retaining Pin
(19). Install the Pin making certain it captures the
Throttle Valve and secures the assembled Trigger.
20. Align the detent hole in the Reverse Valve (5) with
the hole inside the Reverse Valve Bushing (4) and
slide the Valve into the Bushing until almost reaching
the detent hole. Insert the Reverse Valve Detent
Spring (7) and Reverse Valve Detent Ball (6) into the
hole and while compressing the Spring with the Ball,
slide the Valve completely into the Bushing.
21. Using snap ring pliers, install the Reverse Valve
Retainer (8).
22. Slide the Reverse Lever (2) onto the Reverse Valve,
making certain the cast lug enters the notch on the
face of the Reverse Valve Bushing. Secure the Lever
to the Valve by inserting the Reverse Lever Retaining
Pin (3).
Assembly of the Impulse Mechanism
1. Insert the long shaft of the Piston Stop (69) into the
central opening of the Oring Installer furnished with
the Tool Kit (Part No. 1900P99). Place the Piston
Stop Seal (70) on the tapered end of the Installer and
roll the Seal up the taper and into the groove on the
large body of the Piston Stop. Repeat the procedure
with the other Piston Stop and Seal.
2. When looking inside the central opening of the Liner
Assembly (66), the internal wall has three holes on
one side which do not extend through the wall. The
opening on the end face of that wall is for the Torque
Valve Piston (68). Install the Torque Valve Piston,
large end trailing, into that opening.
3. Insert the Piston Stop Assist Spring (71) into the hole
in the end face of the opposite wall.
4. Thread the Threaded Tee Wrench furnished with the
Tool Kit into one of the Piston Stop Assemblies and
using the Wrench to hold the Assembly, insert the
Assembly into the opening against Piston. Mark this
opening with a felt marker to indicate that it contains
the Torque Valve Piston.
5. Unscrew the Wrench and in the same manner, install
the other Piston Stop Assembly in the hole with the
Spring.
6. Install the Rear Liner Cover Seal (72) in the annular
groove on the face of the Rear Liner Cover (73).
7. Install the two Front Liner Cover Piston Seals (59) in
the openings on the face of the Front Liner Cover
(50).
8. Install the Seal BackUp Ring (58) followed by the
Drive Shaft Oring (57) in the central opening in the
face of the Front Liner Cover.
9. Insert the short round hub of the Drive Shaft (61) into
the central opening of the Rear Liner Cover.
10. Insert a Blade (64) into one slot in the Drive Shaft.
Install the Blade Springs (65) through the Drive Shaft
and into the holes in the Blade. Place the remaining
Blade on the Springs making certain the Springs enter
the holes in that Blade.
11. Using finger pressure, compress the Springs with the
Blades until the outer edges of the Blades are flush
with the drive shaft surface. Capture the Blades in
thisposition by installing the Liner Assembly, piston
stop end trailing, over the Drive Shaft and against the
Rear Liner Cover.
21
MAINTENANCE SECTION
This installation can be accomplished more easily
by aligning the compressed Blades with the webs at
the narrowest portion of the opening. Keeping the
Blades on the web allows them to slide the length of
the Liner without interference.
12. Insert the hex end of the Rear Liner Cover into the
Disassembly Arbor from the Tool Kit and stand it on a
workbench with the Drive Shaft upward.
13. Install the Front Liner Cover Assembly over the Drive
Shaft and against the Liner. Make certain the Torque
Adjustment Screw (51) aligns with the proper piston
stop opening that was marked during assembly.
14. Install the two Liner Cover Seals (60) in the grooves
inside the Liner Housing (49) near the end with the
external wrench flats.
15. Place the Liner Housing, Seal end trailing, over the
assembled Liner. Make certain the notch in the
trailing end face of the Housing aligns with the Oil
Plug (54) in the Front Liner Cover. Use the Pressing
Sleeve from the Tool Kit to press the Housing over
the Seals and into position. Do not Damage the Seals
during installation.
16. Grasp the flats of the Liner Housing in vise jaws and
using the Spanner Plug furnished with the Tool Kit
and a torque wrench, install the Housing Cap,
castellated end leading. This is a lefthand thread;
rotate the wrench counterclockwise to tighten the
Cap. Tighten the Cap on model 2400P between 173
and 188 ftlb (235 and 254 Nm) torque and on model
3000P between 186 and 200 ftlb (252 and 272 Nm)
torque.
17. Make certain the Drive Shaft rotates freely and then
fill the mechanism with fluid and reassemble the tool
as instructed in the section, CHANGING THE
MECHANISM FLUID.
18. After assembling the tool, check the torque output
with a torque tester or pulse counter.
If the output is not acceptable, adjust the torque
output as instructed in the section TORQUE
ADJUSTMENT.
If the output is acceptable, proceed as follows:
a. Using a hex wrench, remove the four Hammer
Case Cap Screws (40) and Lock Washers (41). Lift
the Hammer Case (36) off the Motor Housing (1)
over the Drive Shaft. Remove the Hammer Case
Gasket (39).
b. Lift the assembled mechanism off the Rotor (27).
c. Grasp the flats of the Housing (49) in vise jaws
with the output end of the Drive Shaft downward.
d. Insert the pins of the Spanner Plug from the
No. 1900P99 Tool Kit into two holes in the
Housing Cap (74). Using a wrench on the plug,
unscrew and remove the Housing Cap from the
Housing. This is a lefthand thread, rotate the plug
counterclockwise to loosen the Cap.
e. Apply thread sealant to the threads of the Cap and
using the Spanner Plug furnished with the Tool Kit
and a torque wrench, install the Housing Cap,
castellated end leading. This is a lefthand thread;
rotate the wrench counterclockwise to tighten the
Cap. Tighten the Cap on model 2400P between
173 and 188 ftlb (235 and 254 Nm) torque and
on model 3000P between 186 and 200 ftlb (252
and 272 Nm) torque.
f. Position a new Hammer Case Gasket (39) on the
Motor Housing and install the assembled
mechanism on the rotor shaft.
g. Place the Hammer Case Cover over the Drive
Shaft against the Housing and Gasket. Install the
four Hammer Case Cap Screws and Lock
Washers. Tighten each Screw between 45 an 50
inlb (5.1 and 5.6 Nm) torque.
h. Install the Rubber Housing Boot on the tool.
22
NOTES
23
NOTES

Transcripción de documentos

03539509 Form P7078 Edition 5 June, 2000 OPERATION AND MAINTENANCE MANUAL FOR MODELS 2400P AND 3000P TWIN BLADE IMPULSE WRENCHES F E P Models 2400P and 3000P Impulse Wrenches are designed for assembly operations which require high speed rundown of fasteners with consistent torque delivery and reduced torque reaction. Ingersoll–Rand is not responsible for customer modification of tools for applications on which Ingersoll–Rand was not consulted. IMPORTANT SAFETY INFORMATION ENCLOSED. READ THIS MANUAL BEFORE OPERATING TOOL. IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PLACE THE INFORMATION IN THIS MANUAL INTO THE HANDS OF THE OPERATOR. FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY. PLACING TOOL IN SERVICE • • • • • • • • Always operate, inspect and maintain this tool in accordance with American National Standards Institute Safety Code for Portable Air Tools (ANSI B186.1). For safety, top performance, and maximum durability of parts, operate this tool at 90 psig (6.2 bar/620 kPa) maximum air pressure at the inlet with 1/2” (13 mm) inside diameter air supply hose. Always turn off the air supply and disconnect the air supply hose before installing, removing or adjusting any accessory on this tool, or before performing any maintenance on this tool. Do not use damaged, frayed or deteriorated air hoses and fittings. Be sure all hoses and fittings are the correct size and are tightly secured. See Dwg. TPD905–1 for a typical piping arrangement. Always use clean, dry air at 90 psig (6.2 bar/620 kPa) maximum air pressure. Dust, corrosive fumes and/or excessive moisture can ruin the motor of an air tool. Do not lubricate tools with flammable or volatile liquids such as kerosene, diesel or jet fuel. Do not remove any labels. Replace any damaged label. USING THE TOOL • • • • • • • • • • • Always wear eye protection when operating or performing maintenance on this tool. Always wear hearing protection when operating this tool. Keep hands, loose clothing and long hair away from rotating end of tool. Anticipate and be alert for sudden changes in motion during start up and operation of any power tool. Keep body stance balanced and firm. Do not overreach when operating this tool. High reaction torques can occur at or below the recommended air pressure. Tool shaft may continue to rotate briefly after throttle is released. Air powered tools can vibrate in use. Vibration, repetitive motions or uncomfortable positions may be harmful to your hands and arms. Stop using any tool if discomfort, tingling feeling or pain occurs. Seek medical advice before resuming use. Use accessories recommended by Ingersoll–Rand. Use only impact sockets and accessories. Do not use hand (chrome) sockets or accessories. This tool is not designed for working in explosive atmospheres. This tool is not insulated against electric shock. The use of other than genuine Ingersoll–Rand replacement parts may result in safety hazards, decreased tool performance, and increased maintenance, and may invalidate all warranties. Repairs should be made only by authorized trained personnel. Consult your nearest Ingersoll–Rand Authorized Servicenter. Refer All Communications to the Nearest Ingersoll–Rand Office or Distributor.  Ingersoll–Rand Company 2000 Printed in Japan WARNING LABEL IDENTIFICATION FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY. WARNING WARNING Always wear eye protection when operating or performing maintenance on this tool. Always wear hearing protection when operating this tool. WARNING WARNING Air powered tools can vibrate in use. Vibration, repetitive motions or uncomfortable positions may be harmful to your hands and arms. Stop using any tool if discomfort, tingling feeling or pain occurs. Seek medical advice before resuming use. Do not carry the tool by the hose. WARNING Always turn off the air supply and disconnect the air supply hose before installing, removing or adjusting any accessory on this tool, or before performing any maintenance on this tool. WARNING Do not use damaged, frayed or deteriorated air hoses and fittings. WARNING 90 psig (6.2bar/620kPa) Operate at 90 psig (6.2 bar/ 620 kPa) Maximum air pressure. WARNING Keep body stance balanced and firm. Do not overreach when operating this tool. ADJUSTMENTS TORQUE ADJUSTMENT 4. Using a 2 mm hex wrench, rotate the Torque Adjustment Screw clockwise until the Screw stops. Rotate the Screw counterclockwise until it stops or makes six complete revolutions. 5. Using a 2.5 mm hex wrench, unscrew and remove the Oil Plug. Remove the Oil Plug Seal and Oil Plug Seal Support. 6. With the oil plug opening downward over a container, rotate the Drive Shaft to purge the fluid from the mechanism. 7. Thread the Tee Wrench included with the Tool Kit (Part No. 1900P–99) into the Piston Stop Assembly that is 180 degrees from the Torque Adjustment Screw and pull the Stop Assembly toward the output end of the mechanism until it stops. 8. Using the syringe and fluid from the Fluid Replacement Kit (Part No. EQ106S–K400), fill the mechanism with the fluid furnished in the Kit until the fluid overflows the fill hole. Model 2400P will require 30 cc of fluid, Model 3000P, 43 cc. See Dwg. TPD1265. To adjust the torque on these Twin Blade Impulse Wrenches, proceed as follows: 1. Remove the Adjustment Hole Plug. 2. Rotate the Drive Shaft until the Torque Adjustment Screw is visible in the opening. 3. Using a 1.5 mm hex wrench, rotate the Adjustment Screw clockwise to increase the torque output and counterclockwise to decrease the torque output. Do not rotate the Oil Plug. Make all final adjustments at the job. 4. Replace the Adjustment Hole Plug. CHANGING THE MECHANISM FLUID To change the Mechanism Fluid in the Impulse Mechanism, proceed as follows: 1. Remove the Rubber Housing Boot. 2. Using a hex wrench, remove the four Hammer Case Cap Screws and Lock Washers. Lift the Hammer Case off the Motor Housing over the Drive Shaft. Remove the Hammer Case Gasket. 3. Lift the assembled mechanism off the Rotor. DO NOT SUBSTITUTE ANY OTHER FLUID. Failure to use the impulse mechanism fluid provided could damage the tool, increase maintenance and decrease performance. Use only clean fluid in these tools. 2 ADJUSTMENTS 11. Thread the Oil Plug with the Oil Plug Seal and Seal Support into the mechanism until it is snug. 12. Using a 2 mm hex wrench, turn the Torque Adjustment Screw clockwise until it stops. This is the maximum torque position. 13. Wipe the outside of the mechanism dry and clean and remove the Oil Chamber Plug. Using the syringe, withdraw 0.5 cc of fluid from 2400P models and 1.0 cc from 3000P models. 14. Install the Oil Chamber Plug and tighten it between 20 and 25 in–lb (2.3 and 2.8 Nm) torque. 15. Position a new Hammer Case Gasket on the Motor Housing and install the assembled mechanism on the rotor shaft. 16. Place the Hammer Case Cover over the Drive Shaft against the Housing and Gasket. Install the four Hammer Case Cap Screws and Lock Washers. Tighten each Screw between 45 and 50 in–lb (5.1 and 5.6 Nm) torque. 17. Install the Rubber Housing Boot on the tool. (Dwg. TPD1265) 9. Submerge the fill opening in the remainder of the fluid, and using a wrench, rotate the Drive Shaft to purge any remaining air from the system. 10. Remove the mechanism from from the fluid and use the Tee Wrench to push the Piston Stop Assembly slowly downward until fluid flows from the fill opening. PLACING TOOL IN SERVICE MAIN LINES 3 TIMES AIR TOOL INLET SIZE LUBRICATION Ingersoll–Rand No. 50 TO AIR SYSTEM Ingersoll–Rand No. 67 Ingersoll–Rand Fluid Part No. EQ106S–400–1 TO AIR TOOL Always use an air line lubricator with these tools. We recommend the following Filter–Lubricator–Regulator Unit: LUBRICATOR REGULATOR FILTER BRANCH LINE 2 TIMES AIR TOOL INLET SIZE USA – No. C18–03–FKG0–28 After each 20 000 cycles, or as experience indicates, drain and refill the Impulse Unit Drive Assembly as instructed in this manual using the Fluid Replacement Kit (Part No. EQ106S–K400). Lubricate the hex drive and the output shaft before assembly. DRAIN REGULARLY COMPRESSOR (Dwg. TPD905–1) HOW TO ORDER AN IMPULSE WRENCH Model Free Speed Recommended Torque Range Soft Draw ft–lb Hard Slam Nm ft–lb Nm 107–170 145–230 124–210 169–286 PISTOL GRIP with 1/2” SQUARE DRIVE 2400P 4,300 35–80 47–108 PISTOL GRIP with 3/4” SQUARE DRIVE 3000P 4,500 60–110 3 82–150 F MANUEL D’EXPLOITATION ET D’ENTRETIEN DES CLÉS HYDRO–PNEUMATIQUES À DOUBLE PALETTE MODÈLES 2400P ET 3000P NOTE Les clés hydro–pneumatiques à double palette Modèles 2400P et 3000P sont destinées aux opérations d’assemblage nécessitant une grande vitesse de serrage avec une régularité du couple et un serrage virtuellement sans réaction sur l’opérateur. Ingersoll–Rand ne peut être tenu responsable de la modification des outils par le client pour les adapter à des applications qui n’ont pas été approuvées par Ingersoll–Rand. ATTENTION D’IMPORTANTES INFORMATIONS DE SÉCURITÉ SONT JOINTES. LIRE CE MANUEL AVANT D’UTILISER L’OUTIL. L’EMPLOYEUR EST TENU DE COMMUNIQUER LES INFORMATIONS DE CE MANUEL AUX EMPLOYÉS UTILISANT CET OUTIL. LE NON RESPECT DES AVERTISSEMENTS SUIVANTS PEUT CAUSER DES BLESSURES. MISE EN SERVICE DE L’OUTIL UTILISATION DE L’OUTIL S • • • • • • • • Toujours exploiter, inspecter et entretenir cet outil conformément au Code de sécurité des outils pneumatiques portatifs de l’American National Standards Institute (ANSI B186.1). Pour la sécurité, les performances optimales et la durabilité maximale des pièces, cet outil doit être connecté à une alimentation d’air comprimé de 6,2 bar (620 kPa) maximum à l’entrée, avec un flexible de 13 mm de diamètre intérieur. Couper toujours l’alimentation d’air comprimé et débrancher le flexible d’alimentation avant d’installer, déposer ou ajuster tout accessoire sur cet outil, ou d’entreprendre une opération d’entretien quelconque sur l’outil. Ne pas utiliser des flexibles ou des raccords endommagés, effilochés ou détériorés. S’assurer que tous les flexibles et les raccords sont correctement dimensionnés et bien serrés. Voir Plan TPD905–1 pour un exemple type d’agencement des tuyauteries. Utiliser toujours de l’air sec et propre à une pression maximum de 6,2 bar (620 kPa). La poussière, les fumées corrosives et/ou une humidité excessive peuvent endommager le moteur d’un outil pneumatique. Ne jamais lubrifier les outils avec des liquides inflammables ou volatiles tels que le kérosène, le gasoil ou le carburant d’aviation. Ne retirer aucune étiquette. Remplacer toute étiquette endommagée. • • • • • • • • • • Porter toujours des lunettes de protection pendant l’utilisation et l’entretien de cet outil. Porter toujours une protection acoustique pendant l’utilisation de cet outil. Tenir les mains, les vêtements flous et les cheveux longs, éloignés de l’extrémité rotative de l’outil. Prévoir, et ne pas oublier, que tout outil motorisé est susceptible d’à–coups brusques lors de sa mise en marche et pendant son utilisation. Garder une position équilibrée et ferme. Ne pas se pencher trop en avant pendant l’utilisation de cet outil. Des couples de réaction élevés peuvent se produire à, ou en dessous, de la pression d’air recommandée. La rotation des accessoires de l’outil peut continuer pendant un certain temps après le relâchement de la gâchette. Les outils pneumatiques peuvent vibrer pendant l’exploitation. Les vibrations, les mouvements répétitifs et les positions inconfortables peuvent causer des douleurs dans les mains et les bras. N’utiliser plus d’outils en cas d’inconfort, de picotements ou de douleurs. Consulter un médecin avant de recommencer à utiliser l’outil. Utiliser les accessoires recommandés par Ingersoll-Rand. N’utiliser que les douilles et les accessoires pour clés à chocs. Ne pas utiliser les douilles et accessoires (chromés) de clés manuelles. Cet outil n’est pas conçu pour fonctionner dans des atmosphères explosives. Cet outil n’est pas isolé contre les chocs électriques. NOTE L’utilisation de rechanges autres que les pièces d’origine Ingersoll–Rand peut causer des risques d’insécurité, réduire les performances de l’outil et augmenter l’entretien, et peut annuler toutes les garanties. Les réparations ne doivent être effectuées que par des réparateurs qualifiés autorisés. Consultez votre Centre de Service Ingersoll–Rand le plus proche. Adressez toutes vos communications au Bureau Ingersoll–Rand ou distributeur le plus proche.  Ingersoll–Rand Company 2000 Imprimé au Japon SIGNIFICATION DES ÉTIQUETTES D’AVERTISSEMENT ATTENTION LE NON RESPECT DES AVERTISSEMENTS SUIVANTS PEUT CAUSER DES BLESSURES. ATTENTION ATTENTION ATTENTION Couper toujours l’alimentation d’air comprimé et débrancher le flexible d’alimentation avant d’installer, déposer ou ajuster tout accessoire sur cet outil, ou d’entreprendre une opération d’entretien quelconque sur l’outil. Porter toujours une protection acoustique pendant l’utilisation de cet outil. Porter toujours des lunettes de protection pendant l’utilisation et l’entretien de cet outil. ATTENTION Les outils pneumatiques peuvent vibrer pendant l’exploitation. Les vibrations, les mouvements répétitifs et les positions inconfortables peuvent causer des douleurs dans les mains et les bras. N’utiliser plus d’outils en cas d’inconfort, de picotements ou de douleurs. Consulter un médecin avant de recommencer à utiliser l’outil. ATTENTION ATTENTION Ne pas utiliser des flexibles ou des raccords endommagés, effilochés ou détériorés. Ne pas transporter l’outil par son flexible. ATTENTION 90 psig (6.2bar/620kPa) Utiliser de l’air comprimé à une pression maximum de 6,2 bar (620 kPa). ATTENTION Garder une position équilibrée et ferme. Ne pas se pencher trop en avant pendant l’utilisation de cet outil. RÉGLAGES RÉGLAGE DU COUPLE Pour ajuster le couple sur ces clés à impulsions à double palette, procéder comme suit : 1. Déposer le bouchon du trou de réglage. 2. Tourner l’arbre d’entraînement jusqu’à ce que la vis de réglage de couple soit visible dans l’ouverture. 3. A l’aide d’une clé pour six pans creux de 1,5 mm, tourner la vis dans le sens des aiguilles d’une montre pour augmenter le couple de serrage, ou dans le sens inverse des aiguilles d’une montre pour réduire le couple. Ne pas tourner le bouchon d’huile. 5. 6. 7. NOTE Effectuer tous les réglages finaux sur l’écrou à serrer. 4. Remonter le bouchon dans le trou de réglage. 8. CHANGEMENT DU FLUIDE DU MÉCANISME Le fluide du mécanisme d’impulsion est changé de la façon suivante : 1. Déposer la gaine en caoutchouc du corps. 2. A l’aide d’une clé pour six pans creux, déposer les quatre vis du carter de marteau et les rondelles frein. Retirer le carter de marteau du corps du moteur sur l’arbre d’entraînement. Déposer le joint du carter de marteau. 3. Retirer le mécanisme assemblé du rotor. 4. A l’aide d’une clé pour six pans creux de 2 mm, tourner la vis de réglage de couple dans le sens des aiguilles d’une montre jusqu’à ce qu’elle vienne en butée. Tourner la vis dans le sens inverse des aiguilles d’une montre jusqu’à ce qu’elle vienne en butée, ou après six tours complets. A l’aide d’une clé pour six pans creux de 2,5 mm, dévisser et déposer le bouchon d’huile. Déposer le joint du bouchon d’huile et la bague d’appui du joint. Tout en tenant le trou du bouchon d’huile vers le bas au–dessus d’un récipient, tourner l’arbre d’entraînement pour purger le fluide contenu dans le mécanisme. Visser la clé en T fournie dans le nécessaire d’outillage (Réf. No. 1900P–99) dans la butée de piston qui se trouve à 180_ par rapport à la vis de réglage de couple et tirer l’ensemble de butée vers la sortie et le mécanisme jusqu’à ce qu’il s’arrête. A l’aide de la seringue et du fluide fourni dans le nécessaire de fluide de remplacement (Réf. No. EQ106S–K400), remplir le mécanisme avec le fluide fourni jusqu’à ce qu’il déborde du trou de remplissage. Le Modèle 2400P nécessite 30 cm3 de fluide et le Modèle 3000P nécessite 43 cm3. Voir Plan TPD1265. NOTE NE PAS UTILISER D’AUTRE FLUIDE. La non utilisation du fluide fourni pourrait causer l’endommagement de l’outil, augmenter l’entretien et réduire les performances. N’utiliser que du fluide propre dans ces outils. 5 RÉGLAGES 11. Visser le bouchon, équipé du joint et de son support, dans le mécanisme et le serrer fermement. 12. A l’aide d’une clé pour six pans creux de 2 mm, tourner la vis de réglage de couple dans le sens des aiguilles d’une montre jusqu’à ce qu’elle vienne en butée. C’est la position de couple maximum. 13. Essuyer l’extérieur du mécanisme pour le sécher et déposer le bouchon de la chambre d’huile. A l’aide de la seringue, retirer 0,5 cm3 de fluide sur le modèle 2400P et 1 cm3 sur le modèle 3000P. 14. Remonter le bouchon de la chambre d’huile et le serrer à un couple de 2,3 à 2,8 Nm. 15. Placer une nouvelle garniture de carter de marteau sur le corps de moteur et installer le mécanisme assemblé sur l’arbre du rotor. 16. Placer le couvercle de carter de marteau sur l’arbre d’entraînement et contre le corps et son joint. Monter les quatre vis à six pans creux du carter de marteau et les rondelles frein. Serrer chaque vis à un couple de 5,1 à 5,6 Nm. 17. Monter la gaine en caoutchouc sur l’outil. (Plan TPD1265) 9. Submerger l’ouverture de remplissage dans le reste du fluide et, à l’aide d’une clé, tourner l’arbre d’entraînement pour purger tout l’air du système. 10. Retirer le mécanisme du fluide et, à l’aide de la clé en T, pousser l’ensemble de butée de piston lentement vers le bas jusqu’à ce que le fluide déborde de l’ouverture de remplissage. MISE EN SERVICE DE L’OUTIL LUBRIFICATION Ingersoll–Rand No.50 TUYAUTERIE PRINCIPALE AU MOINS 3 FOIS LA DIMENSION DE L’ADMISSION D’AIR DE L’OUTIL VERS LE RÉSEAU D’AIR COMPRIMÉ Ingersoll–Rand No. 67 Fluide Ingersoll–Rand Référence EQ106S–400–1 Utiliser toujours un lubrificateur avec ces outils. Nous recommandons l’emploi du filtre–régulateur–lubrificateur suivant : VERS L’OUTIL PNEUMATIQUE LUBRIFICATEUR É. U. – C18–03–FKG0–28 FILTRE RÉGULATEUR LIGNE SECONDAIRE AU MOINS 2 FOIS LA DIMENSION DE L’ADMISSION D’AIR DE L’OUTIL Tous les 20 000 cycles, ou en fonction de l’expérience, vider et remplir l’ensemble de mécanisme d’impulsion conformément aux instructions du manuel en utilisant le nécessaire de fluide de remplacement (Réf. No. EQ106S–K400). Lubrifier l’entraîneur hexagonal et l’arbre de sortie avant l’assemblage. VIDANGER RÉGULIÈREMENT 6 COMPRESSEUR (Plan TPD905–1) MANUAL DE FUNCIONAMIENTO Y MANTENIMIENTO PARA LLAVES DE IMPULSO DE DOBLE PALETA MODELOS 2400P Y 3000P E NOTA Las llaves de impulso modelos 2400P y 3000P está diseñadas para operaciones de ensamblaje que requieran alta velocidad de atornillado con un par consistente y reducida reacción de par. Ingersoll–Rand no aceptará responsabilidad alguna por la modificación de las herramientas efectuada por el cliente para las aplicaciones que no hayan sido consultadas con Ingersoll–Rand. AVISO SE ADJUNTA INFORMACIÓN IMPORTANTE DE SEGURIDAD. LEA ESTE MANUAL ANTES DE UTILIZAR LA HERRAMIENTA. ES RESPONSABILIDAD DE LA EMPRESA ASEGURARSE DE QUE EL OPERARIO ESTÉ AL TANTO DE LA INFORMACIÓN QUE CONTIENE ESTE MANUAL. EL HACER CASO OMISO DE LOS AVISOS SIGUIENTES PODRÍA OCASIONAR LESIONES. • Use siempre protección para los oídos cuando PARA PONER LA HERRAMIENTA EN SERVICIO S • • • • • • • Utilice, examine y mantenga siempre esta herramienta conforme al código de seguridad para herramientas neumáticas portátiles de la American National Standards Institute (ANSI B186.1). Para mayor seguridad, rendimiento óptimo y larga vida útil de las piezas, utilice esta herramienta a una presión de aire máxima de 90 psig (6,2 bar/620 kPa) con una manguera de suministro de aire con diámetro interno de 13 mm. Corte siempre el suministro de aire y desconecte la manguera de suministro de aire antes de instalar, desmontar o ajustar cualquier accesorio de esta herramienta, o antes de realizar cualquier operación de mantenimiento de la misma. No utilice mangueras de aire y racores dañados, desgastados o deteriorados. Asegúrese de que todos los racores y mangueras sean del tamaño correcto y estén bien apretados. El Esq. TPD905–1 muestra una disposición característica de las tuberías. Use siempre aire limpio y seco a una presión máxima de 90 psig (6,2 bar/620 kPa). El polvo, los gases corrosivos y el exceso de humedad pueden estropear el motor de una herramienta neumática. No lubrique las herramientas con líquidos inflamables o volátiles tales como queroseno, gasoil o combustible para motores a reacción. No saque ninguna etiqueta. Sustituya toda etiqueta dañada. UTILIZACIÓN DE LA HERRAMIENTA • • • • • • • • • • utilice esta herramienta. Mantenga las manos, la ropa suelta y el cabello largo alejados del extremo giratorio de la herramienta. Anticipe y esté atento a los cambios repentinos en el movimiento durante la puesta en marcha y utilización de toda herramienta motorizada. Mantenga una postura del cuerpo equilibrada y firme. No estire demasiado los brazos al manejar la herramienta. Pueden darse elevados pares de reacción a la presión de aire recomendada, e incluso a presiones inferiores. El eje de la herramienta puede seguir girando brevemente después de haberse soltado el mando. Las herramientas neumáticas pueden vibrar durante el uso. La vibración, los movimientos repetitivos o las posiciones incómodas pueden dañarle los brazos y manos. En caso de incomodidad, sensación de hormigueo o dolor, deje de usar la herramienta. Consulte con el médico antes de volver a utilizarla. Utilice únicamente los accesorios Ingersoll–Rand recomendados. Utilice únicamente bocas y accesorios para llaves de impacto. No utilice bocas o accesorios manuales (cromados). Esta herramienta no ha sido diseñada para trabajar en ambientes explosivos. Esta herramienta no está aislada contra descargas eléctricas. Use siempre protección ocular cuando utilice esta herramienta o realice operaciones de mantenimiento en la misma. NOTA El uso de piezas de recambio que no sean las auténticas piezas Ingersoll–Rand puede poner en peligro la seguridad, reducir el rendimiento de la herramienta y aumentar los cuidados de mantenimiento necesarios, así como invalidar toda garantía. Las reparaciones sólo se deben encomendar a personal debidamente cualificado y autorizado. Consulte con el centro de servicio autorizado Ingersoll–Rand más próximo. Toda comunicación se deberá dirigir a la oficina o al distribuidor Ingersoll–Rand más próximo.  Ingersoll–Rand Company 2000 Impreso en Japón ETIQUETAS DE AVISO AVISO EL HACER CASO OMISO DE LOS AVISOS SIGUIENTES PODRÍA OCASIONAR LESIONES. ADVERTENCIA ADVERTENCIA Use siempre protección ocular cuando utilice esta herramienta o realice operaciones de mantenimiento en la misma. ADVERTENCIA Cortar siempre el suministro de aire y desconectar la manguera de suministro de aire antes de instalar, retirar o ajustar cualquier accesorio de esta herramienta, o antes de realizar cualquier operación de mantenimiento de la misma. Use siempre protección para los oídos cuando utilice esta herramienta. ADVERTENCIA Las herramientas neumáticas pueden vibrar durante el uso. La vibración, los movimientos repetitivos o las posiciones incómodas podrían dañarle los brazos y las manos. En caso de incomodidad, sensación de hormigueo o dolor, dejar de usar la herramienta. Consultar al médico antes de volver a utilizarla. ADVERTENCIA ADVERTENCIA No utilizar mangueras de aire y accesorios dañados, desgastados ni deteriorados. No coger la herramienta por la manguera para levantarla. ADVERTENCIA 90 psig (6.2bar/620kPa) Manejar la herramienta a una presión de aire máxima de 90 psig (6,2 bar/620 kPa). ADVERTENCIA Mantener una postura del cuerpo equilibrada y firme. No estirar demasiado los brazos al manejar la herramienta. AJUSTES AJUSTE DE PAR 4. Con una llave hexagonal de 2 mm, gire el tornillo de ajuste de par hacia la derecha hasta que se pare. Gire el tornillo hacia la izquierda hasta que se pare o dé seis vueltas completas. 5. Con una llave hexagonal de 2,5 mm, desenrosque y saque el tapón del aceite. Saque el retén del tapón del aceite y el soporte de dicho retén. 6. Con el orificio del tapón del aceite apuntando hacia abajo sobre un contenedor, gire el eje de accionamiento para purgar el líquido del mecanismo. 7. Enrosque la llave en “T” que se incluye en la caja de herramientas (Ref. Nº 1900P–99)) en el conjunto del tope del pistón que se encuentra a 180 grados del tornillo de ajuste de par, y tire de dicho conjunto hacia el extremo de salida del mecanismo hasta que se pare. 8. Con la jeringuilla y el líquido del juego de cambio de líquido (Ref. Nº EQ106S–K400), llene el mecanismo con el líquido suministrado en dicho equipo hasta que el líquido se salga del orificio de llenado. El modelo 2400P requerirá 30 cc de líquido, y el modelo 3000P, 43 cc. Vea Esq. TPD1265. Para ajustar el par de estas llaves de impulso de doble paleta, proceda como sigue: 1. Saque el tapón del orificio de ajuste. 2. Gire el eje de accionamiento hasta que el tornillo de ajuste de par sea visible a través de dicho orificio. 3. Con una llave hexagonal de 1,5 mm, gire el tornillo de ajuste de par hacia la derecha para incrementar el par y hacia la izquierda para disminuirlo. No gire el tapón del aceite. NOTA Haga todos los ajustes finales trabajando. 4. Vuelva a poner en su sitio el tapón del orificio de ajuste. CAMBIO DEL LÍQUIDO DEL MECANISMO Para cambiar el líquido del mecanismo de impulso, proceda como sigue: NOTA 1. Saque la funda de la carcasa de caucho. 2. Utilizando una llave hexagonal, saque los cuatro tornillos de la caja de mazas y las arandelas de seguridad. Levante la caja de mazas y sáquela de la carcasa del motor por encima del eje de accionamiento. Saque la junta obturadora de la caja de mazas. 3. Levante el mecanismo ensamblado y sáquelo del rotor. NO SUSTITUYA CON NINGÚN OTRO LÍQUIDO. Si no se usa el líquido de mecanismo impulsor suministrado, se podría dañar la herramienta, incrementar su mantenimiento y disminuir su rendimiento. Use solamente líquido limpio con estas herramientas. 8 AJUSTES 11. Enrosque el tapón del aceite con el retén del tapón de aceite y el soporte del retén en el mecanismo hasta que quede bien ajustado. 12. Con una llave hexagonal de 2 mm, gire el tornillo de ajuste de par hacia la derecha hasta que se pare. Ésta es la posición de máximo par. 13. Limpie la parte de fuera del mecanismo y séquelo, y saque el tapón de la cámara de aceite. Utilizando la jeringuilla, saque 0,5 cc de líquido de los modelos 2400P, y 1,0 cc de los modelos 3000P. 14. Instale el tapón de la cámara de aceite y apriételo entre 20 y 25 pulg.–lb (2,3 a 2,8 Nm) de par. 15. Coloque una junta obturadora de la caja de mazas nueva en la carcasa del motor e instale el mecanismo ensamblado en el eje rotor. 16. Coloque la cubierta de la caja de mazas sobre el eje de accionamiento y contra la carcasa y la junta obturadora. Instale los cuatro tornillos de la caja de mazas y las arandelas de seguridad. Apriete cada tornillo entre 45 y 50 pulg–lb ( 5,1 y 5,6 Nm) de par. 17. Instale la funda de la carcasa de caucho en la herramienta. (Esq. TPD1265) 9. Sumerja el orificio de llenado en el resto del líquido y, utilizando una llave, gire el eje de accionamiento para purgar el aire que pudiera quedar en el sistema. 10. Saque el mecanismo del líquido y utilice la llave en “T” para empujar lentamente el conjunto de tope del pistón hacia abajo hasta que el líquido se salga del orificio de llenado. PARA PONER LA HERRAMIENTA EN SERVICIO LUBRICACIÓN AL SISTEMA NEUMÁTICO Ingersoll–Rand Nº 50 Ingersoll–Rand Nº 67 Líquido Ingersoll–Rand Nº EQ106S–400–1 TUBERÍAS PRINCIPALES 3 VECES EL TAMAÑO DE ENTRADA DE HERRAMIENTA NEUMÁTICA A LA HERRA– MIENTA NEUMÁTICA Utilice siempre un lubricador de aire comprimido con estas herramientas. Recomendamos utilizar el siguiente conjunto de filtro–lubricador–regulador: LUBRICADOR REGULADOR TUBERÍA DE RAMAL 2 VECES EL TAMAÑO DE ENTRADA DE HERRAMIENTA NEUMÁTICA EE.UU. – C11–03–G00 Después de cada 20 000 ciclos, o según indique la experiencia, drene y vuelva a llenar el conjunto de accionamiento del mecanismo impulsor tal y como se indica en este manual, utilizando el juego de cambio de líquido (Ref. Nº EQ106S–K400). Lubrique el eje de salida y el de accionamiento hexagonal antes del montaje. PURGAR PERIÓDICAMENTE 9 FILTRO COMPRESOR (Esq. TPD905–1) MANUAL DE FUNCIONAMENTO E MANUTENÇÃO PARA FERRAMENTAS PNEUMÁTICAS DE IMPULSÃO DE LÂMINAS DUPLAS MODELOS 2400P E 3000P P AVISO As Ferramentas Pneumáticas de Impulsão Modelos 2400P e 3000P são concebidas para operações de montagem que exijam velocidade de aperto elevada com torque exercido consistente e reacção de torque reduzida. A Ingersoll–Rand não é responsável por modificações feitas pelo cliente em ferramentas nas quais a Ingersoll–Rand não tenha sido consultada. ADVERTÊNCIA INFORMAÇÃO DE SEGURANÇA IMPORTANTE EM ANEXO. LEIA ESTE MANUAL ANTES DE OPERAR A FERRAMENTA. É DA RESPONSABILIDADE DO EMPREGADOR COLOCAR A INFORMAÇÃO DESTE MANUAL NAS MÃOS DO OPERADOR. O NÃO CUMPRIMENTO DAS SEGUINTES ADVERTÊNCIAS PODE RESULTAR EM FERIMENTOS. USANDO A FERRAMENTA COLOCANDO A FERRAMENTA • Use sempre óculos de protecção quando estiver EM FUNCIONAMENTO S • • • • • • • Sempre opere, inspeccione e mantenha esta ferramenta de acordo com o Código de Segurança do Instituto Americano de Padrões Nacionais para Ferramentas Pneumáticas Portáteis (ANSI B186.1). Para segurança, máximo desempenho e máxima durabilidade das peças, opere esta ferramenta com uma pressão de ar máxima de 6,2 bar/620 kPa (90 psig) na entrada da mangueira de alimentação de ar com diâmetro interno de 13 mm (1/2”). Desligue sempre a alimentação de ar e desconecte a mangueira de alimentação de ar antes de instalar, remover ou ajustar qualquer acessório nesta ferramenta, ou antes de executar qualquer serviço de manutenção nesta ferramenta. Não use mangueiras de ar ou adaptadores danificados, gastos ou deteriorados. Certifique–se de que todas as mangueiras e adaptadores sejam do tamanho correcto e estejam apertados com firmeza. Veja o Desenho TPD905–1 para um arranjo típico de tubagem. Use sempre ar seco e limpo com pressão máxima de 6,2 bar/620 kPa (90 psig). Pó, fumos corrosivos e/ou humidade excessiva podem arruinar o motor de uma ferramenta pneumática. Não lubrifique as ferramentas com líquidos inflamáveis ou voláteis tais como querosene, diesel ou combustível de jactos. Não remova nenhum rótulo. Reponha qualquer rótulo danificado. • • • • • • • • • • operando ou executando serviço de manutenção nesta ferramenta. Use sempre protecção contra ruído ao operar esta ferramenta. Mantenha as mãos, partes do vestuário soltas e cabelos compridos afastados da extremidade em rotação. Antecipe e esteja alerta a mudanças repentinas no movimento quando ligar e operar qualquer ferramenta motorizada. Mantenha a posição do corpo equilibrada e firme. Não exagere quando operar esta ferramenta. Torques de reacção elevados podem ocorrer na ou abaixo da pressão de ar recomendada. O eixo da ferramenta pode continuar a girar brevemente após a pressão ter sido aliviada. Ferramentas accionadas pneumáticamente podem vibrar em uso. Vibração, movimentos repetitivos ou posições desconfortáveis podem ser prejudiciais às mãos e aos braços. Pare de usar a ferramenta caso ocorra algum desconforto, sensação de formigueiro ou dor. Procure assistência médica antes de retornar ao trabalho. Use acessórios recomendados pela Ingersoll–Rand. Use somente soquetes e acessórios de impacto. Não use soquetes ou acessórios de mão (cromo). Esta Ferramenta não foi concebida para trabalhos em atmosferas explosivas. Esta Ferramenta não está isolada contra choques eléctricos. AVISO O uso de peças de substituição que não sejam genuinamente da Ingersoll–Rand podem resultar em riscos de segurança, diminuição do desempenho da ferramenta, aumento da necessidade de manutenção e pode invalidar todas as garantias. As reparações devem ser feitas somente por pessoal treinado autorizado. Consulte o Centro de Serviços da Ingersoll–Rand mais próximo. Envie Todos os Comunicados Para o Distribuidor ou Escritório da Ingersoll–Rand Mais Próximo.  Ingersoll–Rand Company 2000 Fabricado no Japão IDENTIFICAÇÃO DO RÓTULO DE ADVERTÊNCIA ADVERTÊNCIA O NÃO CUMPRIMENTO DAS SEGUINTES ADVERTÊNCIAS PODE RESULTAR EM FERIMENTOS. ADVERTÊNCIA ADVERTÊNCIA Use sempre óculos de protecção quando estiver operando ou executando algum serviço de manutenção nesta ferramenta. ADVERTÊNCIA Use sempre protecção contra o ruído ao operar esta ferramenta. Desligue sempre a alimentação de ar e desconecte a mangueira de alimentação de ar antes de instalar, remover ou ajustar qualquer acessório nesta ferramenta, ou antes de executar algum serviço de manutenção nesta ferramenta. ADVERTÊNCIA ADVERTÊNCIA Ferramentas accionadas pneumáticamente podem vibrar em uso. Vibração, movimentos repetitivos ou posições desconfortáveis podem ser prejudiciais às mãos e aos braços. Pare de usar a ferramenta caso ocorra algum desconforto, sensação de formigueiro ou dor. Procure assistência médica antes de retornar ao trabalho. ADVERTÊNCIA Mantenha a posição do corpo equilibrada e firme. Não exagere quando operar esta ferramenta. Torques de reacção elevados podem ocorrer sob a pressão de ar recomendada. Não carregue a ferramenta segurando na mangueira. ADVERTÊNCIA Não use mangueiras de ar ou adaptadores danificados, gastos ou deteriorados. ADVERTÊNCIA 90 psig (6.2bar/620kPa) Opere com pressão do ar Máxima de 90–100 psig (6,2–6,9 bar). AJUSTES AJUSTE DE TORQUE Para ajustar o torque nestas Ferramentas Pneumáticas de Impulso de Lâminas Duplas, proceda da seguinte maneira: 5. 1. Remova o Bujão do Furo de Ajuste. 2. Gire o Eixo de Comando até o Parafuso de Ajuste de Torque estar visível na abertura. 3. Usando uma chave Allen de 1,5 mm, gire o Parafuso de Ajuste no sentido horário para aumentar o torque de saída e no sentido anti–horário para diminuir o torque de saída. Não gire o Bujão de Óleo. 6. 7. AVISO Faça todos os ajustes finais no serviço. 4. Reponha o Bujão do Furo de Ajuste. 8. MUDANDO O FLUIDO DO MECANISMO Para mudar o Fluído do Mecanismo no Mecanismo de Impulso, proceda da seguinte maneira: 1. Remova o Calço do Corpo de Borracha. 2. Usando uma chave Allen, remova os três Parafusos dos Tampos da Caixa do Martelo e Anilhas de Trava. Erga a Caixa do Martelo para fora do Corpo do Motor sobre o Eixo de Comando. Remova a Junta da Culatra da Caixa do Martelo. 3. Erga o mecanismo montado do motor. 4. Usando uma chave Allen de 2 mm gire o Parafuso de Ajuste de Torque no sentido horário até que o Parafuso pare. Gire o Parafuso no sentido contrário ao dos ponteiros do relógio até que ele pare ou complete 6 revoluções. Usando uma chave Allen de 2,5 mm, desparafuse e remova o Bujão de Óleo. Remova o Lacre do Bujão do Óleo e o Suporte do Lacre do Bujão de Óleo. Com a abertura do bujão de óleo para baixo sobre um recipiente, gire o Eixo de Comando para expelir o fluido do mecanismo. Rosqueie a Chave em “T” incluída no Kit de Ferramenta (Número 1900A–99) no Conjunto de Paragem do Pistão que está a 180 graus do Parafuso de Ajuste de Torque e puxe o Conjunto de Paragem em direção à saída do mecanismo até que ele pare. Usando a seringa e fluído do Kit de Reposição de Fluído (Número de Pedido EQ106S–K400), encha o mecanismo com o fluído fornecido no Kit até que o fluído transborde do orifício de enchimento. O Modelo 2400P necessitará 30 cc de fluído, o Modelo 3000P, 43 cc. Veja o Desenho TPD1265. AVISO NÃO SUBSTITUA POR QUALQUER OUTRO FLUÍDO. Caso o fluido fornecido não for usado danos podem ocorrer à ferramenta, aumento da manutenção e diminuição do desempenho. Use somente fluido limpo nestas ferramentas. 11 AJUSTES 11. Rosqueie o Bujão de Óleo com o Lacre do Bujão de Óleo no mecanismo até que ele esteja apertado. 12. Usando uma chave Allen de 2 mm, gire o Parafuso de Ajuste de Torque no sentido horário até o Parafuso parar. Esta é a posição de aperto máximo. 13. Limpe a parte externa do mecanismo a seco e limpe e remova o Bujão da Câmara de Óleo. Usando uma seringa, retire 0,50 cc de fluido do modelo 2400P e 1,0 cc do modelo 3000P. 14. Instale o Bujão da Câmara de Óleo e aperte–o com 2,3 a 2,8 Nm (20 a 25 pol–lb). 15. Posicione a Junta da Culatra da Caixa do Martelo nova no Corpo do Motor e instale o mecanismo montado no eixo do rotor. 16. Coloque a Capa da Caixa do Martelo sobre o Eixo de Comando contra o Corpo e o Junta da Culatra. Instale os três Parafusos do Tampo da Caixa do Martelo e Anilhas de Trava. Aperte cada Parafuso com um torque de 5,1 e 5,6 Nm (45 e 50 pol–lb). 17. Instale o Calço do Corpo de Borracha na ferramenta. (Desenho TPD1265) 9. A abertura de enchimento deve ser submersa no restante do fluido, e usando uma chave, gire o Eixo do Comando para expelir qualquer ar remanescente do sistema. 10. Remova o mecanismo do fluido e use uma Chave em ”T” para empurrar o Conjunto de Paragem do Pistão lentamente para baixo até que o fluido flua da abertura de enchimento. COLOCANDO A FERRAMENTA EM FUNCIONAMENTO LUBRIFICAÇÃO LINHAS PRINCIPAIS 3 VEZES O TAMANHO DA ENTRADA DA FERRAMENTA PNEUMÁTICA PARA SISTEMA DE AR Ingersoll–Rand No. 50 Ingersoll–Rand No. 67 Fluído Ingersoll–Rand Número de Pedido No. EQ106S–400–1 PARA FERRAMENTA PNEUMÁTICA Use sempre um lubrificador de ar de linha com estas ferramentas. Nós recomendamos a seguinte Unidade Filtro–Lubrificador–Regulador: LUBRIFICADOR REGULADOR FILTRO LINHA RAMIFICADA 2 VEZES O TAMANHO DA ENTRADA DA FERRAMENTA PNEUMÁTICA Para os E.U.A. – No. C18–03–FKG0–28 Depois de cada 20 000 ciclos, ou como a experiência indicar, drene e encha o Conjunto do Comando da Unidade de Impulso como instruído neste manual usando o Kit de Reposição de Fluído (Número de Pedido EQ106S–K400). Lubrifique o comando hexagonal e o eixo de saída antes de montar. COMPRESSOR DRENE REGULARMENTE (Desenho TPD905–1) 12 MAINTENANCE SECTION 13 (Dwg. TPA1342) PART NUMBER FOR ORDERING 22 23 24 25 26 27 28 29 30 2400P 2400P–A40 2400P–40 3000P–328 3000P–152 2400P–330 2400P–329 500P–333 1900P–51 1410P–303 1100P–232 EQ112P–A503 EQ106P–283 EQ112P–A304 EQ112P–159 EQ106P–303 EQ112P–A302 EQ106P–288 EQ106P–93 EQ106P–265 180PQ–120 EQ106S–565 2400P–A23 2400P–A53 2400P–A12 2400P–B12 2400P–152 R38P–606 2400P–A3 1900P–152 2400P–53 2400P–42–6 2400P–A11 2400P–22 3000P 3000P–A40 3000P–40 3000P–328 3000P–152 2400P–330 2400P–329 500P–333 1900P–51 1410P–303 1100P–232 EQ112P–A503 EQ106P–283 EQ112P–A304 EQ112P–159 EQ106P–303 EQ112P–A302 EQ106P–288 EQ106P–93 EQ106P–265 180PQ–120 EQ106S–565 2400P–A23 3000P–A53 3000P–A12 EQ230P–A12 EQ230P–99 EQ230P–24 3000P–A3 3000P–152 EQ230P–53 EQ230P–42–6 3000P–A11 2400P–22 MAINTENANCE SECTION 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Motor Housing Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reverse Lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reverse Lever Retaining Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reverse Valve Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reverse Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reverse Valve Detent Ball . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reverse Valve Detent Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reverse Valve Retainer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Suspension Hole Liner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Throttle Bushing Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Throttle Bushing Seal (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Throttle Valve Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Throttle Valve Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Valve Retaining Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Throttle Rod Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Throttle Rod Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trigger Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Throttle Retaining Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inlet Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exhaust Deflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rear End Plate Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rear End Plate Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . End Plate Alignment Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rear Rotor Bearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cylinder Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cylinder Alignment Pin (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vane Packet (set of 6 Vanes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Front End Plate Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Front Rotor Bearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PART NUMBER FOR ORDERING 2400P 31 32 33 34 35 * * 45 46 47 48 * * Not illustrated. 2400P–A202 1100P–232 2400P–739 2400P–277 EQ112P–58 2400P–A727 2400P–727 EQ110P–641 500P–95 2400P–740 2400P–277 EQ112P–58 ––– 2400P–2 3000P–A202 1100P–232 3000P–739 3000P–638 EQ112P–58 3000P–A727 3000P–727 3000P–641 500P–95 3000P–740 3000P–638 EQ112P–58 EQ230P–A48 3000P–2 –––––– 2400P–301 –––––– –––––– EQ106S–322 3000P–EU–301 3000P–301 7802R–EU–F99 7802R–EU–R99 EQ106S–322 –––––– WARNING–2–99 500P–69 180PQ–68 2400P–K500 EU–99 WARNING–2–99 500P–69 180PQ–68 3000P–K500 MAINTENANCE SECTION 15 36 37 38 39 40 41 42 43 44 Motor Case Cover Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Suspension Hole Liner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor Case Cover Gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor Case Cover Screw (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cover Screw Lock Washer (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hammer Case Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hammer Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hammer Case Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjustment Hole Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hammer Case Gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hammer Case Cap Screw (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cap Screw Lock Washer (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dead Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rubber Housing Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate for models ending in –EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for all other models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Forward Rotation Label (for models ending in –EU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reverse Rotation Label (for models ending in –EU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate Screw (2 for 2400P; 4 for 3000P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warning Label for models ending in –EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for all other models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Oil Daily Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Two Speed Trigger Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor Tune–up Kit (includes illustrated items 24, 28, 30 and 33) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000P MAINTENANCE SECTION PART NUMBER FOR ORDERING * 2400P Impulse Unit Drive Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P–A200 49 Liner Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–240 Front Cover Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–A211 50 Front Liner Cover Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–B211 51 Torque Adjustment Screw . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–230 52 Adjustment Screw Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P–288 53 Alignment Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–120 54 Oil Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ230P–277 55 Oil Plug Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ208S–238 56 Oil Plug Seal Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ230P–229 57 Drive Shaft O–ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ110P–271 58 Seal Back–up Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ110P–272 59 Front Liner Cover Piston Seal (2) . . . . . . . . . . . . . . . . . . . . . . . . . 2400P–237 60 Liner Housing Seal (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–238 Drive Shaft Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–A626 61 Drive Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–626 62 Socket Retaining Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804–716 63 Retaining Pin Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5HUD–718 64 Drive Shaft Blade (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–220 65 Blade Spring (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–219 66 Liner Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–A203 67 Liner Alignment Pin (4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–298 68 Torque Valve Piston . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–222 Piston Stop Assembly (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–A255 69 Piston Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–255 70 Piston Stop Seal (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ104S–50 71 Piston Stop Assist Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–219 72 Rear Liner Cover Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P–238 73 Rear Liner Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400P–212 74 Housing Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ112P–207 * Fluid Replacement Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106S–K400 * Replacement Fluid (4 oz.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ106S–400–1 * Mechanism Tune–up Kit (includes illustrated items 55, 56, 57, 58, 59 [2], 60 [2], 70 [2] and 72) . . . . . . . . . . . . . . . 1900P–K600 * Mechanism Tune–up Kit (includes illustrated items 39, 55, 56, 57, 58, 59 [2], 60 [2], 65 [2], 70 [2], 71 and 72) . . . ––– * Tool Kit (includes all the specialized tooling required to repair these tools and consists of a Spanner Plug, Threaded Tee Wrench, O–ring Installer and a pressing fixture that has a Disassembly Arbor and Pressing Sleeve) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1900P–99 Not illustrated. 16 3000P 3000P–A200 EQ230P–240 3000P–A211 3000P–B211 1900P–230 2400P–288 EQ230P–232 EQ230P–277 EQ208S–238 EQ230P–229 EQ230P–271 EQ230P–272 3000P–236 3000P–238 ––– 3000P–626 ––– ––– EQ230P–220 EQ230P–219 3000P–A203 EQ230P–298 EQ230P–222 EQ230P–A255 EQ230P–255 EQ230P–288 1900P–219 3000P–237 EQ230P–212 EQ230P–207 EQ106S–K400 EQ106S–400–1 ––– 3000P–K600A 1900P–99 MAINTENANCE SECTION CHANGING THE MECHANISM FLUID 9. Submerge the fill opening in the remainder of the fluid, and using a wrench, rotate the Drive Shaft to purge any remaining air from the system. 10. Remove the mechanism from from the fluid and use the Tee Wrench to push the Piston Stop Assembly slowly downward until fluid flows from the fill opening. 11. Thread the Oil Plug with the Oil Plug Seal and Seal Support into the mechanism until it is snug. 12. Using a 2 mm hex wrench, turn the Torque Adjustment Screw clockwise until it stops. This is the maximum torque position. 13. Wipe the outside of the mechanism dry and clean and remove the Oil Chamber Plug. Using the syringe, withdraw 0.5 cc of fluid from 2400P models and 1.0 cc from 3000P models. 14. Install the Oil Chamber Plug and tighten it between 20 and 25 in–lb (2.3 and 2.8 Nm) torque. 15. Position a new Hammer Case Gasket on the Motor Housing and install the assembled mechanism on the rotor shaft. 16. Place the Hammer Case Cover over the Drive Shaft against the Housing and Gasket. Install the four Hammer Case Cap Screws and Lock Washers. Tighten each Screw between 45 an 50 in–lb (5.1 and 5.6 Nm) torque. 17. Install the Rubber Housing Boot on the tool. To change the Mechanism Fluid in the Impulse Mechanism, proceed as follows: 1. Remove the Rubber Housing Boot (43). 2. Using a hex wrench, remove the four Hammer Case Cap Screws (40) and Lock Washers (41). Lift the Hammer Case (36) off the Motor Housing (1) over the Drive Shaft. Remove the Hammer Case Gasket (39). 3. Lift the assembled mechanism off the Rotor (27). 4. Using a 2 mm hex wrench, rotate the Torque Adjustment Screw (51) clockwise until the Screw stops. Rotate the Screw counterclockwise until it stops or makes six complete revolutions. 5. Using a 2.5 mm hex wrench, unscrew and remove the Oil Plug (54). Remove the Oil Plug Seal (55) and Oil Plug Seal Support (56). 6. With the oil plug opening downward over a container, rotate the Drive Shaft to purge the fluid from the mechanism. 7. Thread the Tee Wrench included with the Tool Kit (Part No. 1900P–99) into the Piston Stop Assembly (69) that is 180 degrees from the Torque Adjustment Screw and pull the Stop Assembly toward the output end of the mechanism until it stops. 8. Using the syringe and fluid from the Fluid Replacement Kit (Part No. EQ106S–K400), fill the mechanism with the fluid furnished in the Kit until the fluid overflows the fill hole. Model 2400P will require 30 cc of fluid, Model 3000P, 43 cc. (Refer to Dwg. TPD1265) DISASSEMBLY General Instructions 1. Do not disassemble the tool any further than necessary to replace or repair damaged parts. 2. When grasping a tool or part in a vise, always use leather–covered or copper–covered vise jaws to protect the surface of the part and help prevent distortion. This is particularly true of threaded members and housings. 3. Do not remove any part which is a press fit in or on an assembly unless the removal of that part is necessary for repairs or replacement. DO NOT SUBSTITUTE ANY OTHER FLUID. Failure to use the impulse mechanism fluid provided could damage the tool, increase maintenance and decrease performance. Use only clean fluid in these tools. Disassembly of the Impulse Mechanism 1. Use a hooked wire to pull the Retaining Pin Spring (63) out of the end of the Drive Shaft (61) and remove the Socket Retaining Pin (62). 2. Remove the Rubber Housing Boot (43). 3. Using a hex wrench, remove the four Hammer Case Cap Screws (40) and Lock Washers (41). Lift the Hammer Case (36) off the Motor Housing (1) over the Drive Shaft. Remove the Hammer Case Gasket (39). 4. Lift the assembled mechanism off the Rotor (27). 5. Grasp the flats of the Housing (49) in vise jaws with the output end of the Drive Shaft downward. (Dwg. TPD1265) 17 MAINTENANCE SECTION 6. Insert the pins of the Spanner Plug from the No. 1900P–99 Tool Kit into two holes in the Housing Cap (74). Using a wrench on the plug, unscrew and remove the Housing Cap from the Housing. (Refer to Dwg. TPD1267.) 5. While holding the motor end of the Housing above a piece of cardboard on the workbench, lightly tap the rod to remove the Rear End Plate Assembly (22), Rotor (27) and Vanes (28). 6. On the table of an arbor press, support the Rear End Plate with blocks as close to the Rotor as possible and press the Rotor out of the Rear End Plate and Rear Rotor Bearing (24). 7. To remove the Rear Rotor Bearing from the Rear End Plate, use a small drift or pin punch through the central opening of the Rear End Plate to tap the Bearing out of the End Plate. (Refer to Dwg. TPD1271.) It may be necessary to cut the thread sealant around the Housing Cap with a sharp knife before attempting to remove the Cap. SPANNER PLUG COUNTERCLOCKWISE TO LOOSEN Do not enlarge or damage the shaft hole in the End Plate. (Dwg. TPD1267) 7. Stand the Disassembly Arbor from the Tool Kit, large end downward, on a workbench or the table of an arbor press. Insert the output end of the Drive Shaft into the central opening and either tap the Housing downward off the components or use the Pressing Sleeve in the Kit to press the Housing downward off the components. (Refer to Dwg. TPD1268.) (Dwg. TPD1271) PRESSING SLEEVE 8. Using a longer drift punch through the Cylinder (25), tap the Front Rotor Bearing (30) out of the Front End Plate Assembly (29) in the same manner. TAP EDGE LIGHTLY WITH BRASS HAMMER OR USE PRESSING SLEEVE FROM TOOL KIT DISASSEMBLY ARBOR FROM TOOL KIT 9. (Dwg. TPD1268) 8. Disassemble the components of the mechanism in the sequence shown in Drawing TPA1342 on Page 4. 10. Disassembly of the Motor 1. Grasp the Motor Housing (1) in vise jaws with the Motor Case Cover Assembly (31) upward. 2. Using a hex wrench, remove the four Motor Case Cover Screws (34) and Lock Washers (35). 3. Remove the Cover and Motor Case Cover Gasket (33) from the Motor Housing. 4. Remove the Housing from the vise jaws and insert a rod into the central opening in the output end of the rotor shaft. 11. 12. 13. 18 Do not enlarge or damage the shaft hole in the End Plate. The Cylinder and Front End Plate are a shrink fit in the Motor Housing and parts that can be damaged during the heating process must be removed before heating the Housing. Press the Reverse Lever Pin (3) out of the Reverse Lever (2) and pull the lever off the shaft of the Reverse Valve (5). Using snap ring pliers, remove the Reverse Valve Retainer (8). Grasp the shaft of the Reverse Valve with pliers, and pull the Reverse Valve, Reverse Valve Detent Ball (6) and Detent Spring (7) out of the Reverse Valve Bushing (4). Be careful not to lose the Ball and Spring. Using a pin punch, tap the Throttle Retaining Pin (19) out of the Handle. MAINTENANCE SECTION 14. Grasp the Trigger (17) and pull the assembled throttle out of the Motor Housing. 15. Using a pin punch and without damaging the Trigger, remove the Trigger Pin (18). 16. Slide the Throttle Bushing Assembly (10) off the shaft of the Throttle Rod Assembly (15). 17. Using a thin blade screwdriver, remove the Valve Retaining Ring (14) and slide the Throttle Valve Assembly (12) off the shaft of the Throttle Valve Rod. 18. Using an adjustable wrench, unscrew and remove the Inlet Bushing (20) and Exhaust Deflector Assembly (21). 19. Insert a threaded rod through the Cylinder and Front End Plate and install a nut and washer on the end plate end of the rod. Position the Rear End Plate on the threaded rod against the Cylinder and clamp the End Plates and Cylinder snug with another nut and washer. Do not tighten the assembly excessively. 20. Using a heat induction coil or an oven, heat the assembly and Housing until it is warm enough to pull the assembly out the rear of the Motor Housing. Do not apply enough heat to distort the Housing. TUBING BEARING END PLATE (Dwg. TPD1274) 2. Stand the Rotor (27) on the table of an arbor press. It should be upright on a flat metal plate having a clearance hole for the shaft. The shaft with the hex must be upward. 3. Place a 0.001” (0.025 mm) shim on the upward surface of the large portion of the rotor body. Using a piece of tubing that contacts the inner ring of the bearing, press the Front Rotor Bearing and Front End Plate, End Plate leading, onto the shaft of the Rotor until the End Plate contacts the shim. Remove the shim. (Refer to Dwg. TPD1275.) Take all precautions necessary to prevent being burned by handling warm or hot parts. ASSEMBLY PRESSING PLUG General Instructions 1. When grasping a tool or part in a vise, always use leather–covered or copper–covered vise jaws to protect the surface of the part and help prevent distortion. This is particularly true of threaded members and housings. 2. Always press on the inner ring of a ball–type bearing when installing the bearing on a shaft. 3. Always press on the outer ring of a ball–type bearing when pressing the bearing into a bearing recess. 4. Except for bearings and mechanism parts, always clean every part and wipe every part with a thin film of oil before installation. 5. Wipe a thin film of mechanism fluid on all internal mechanism components before installing them in the mechanism. 6. Apply a film of O–ring lubricant to every O–ring before installation. FRONT ROTOR BEARING FRONT END PLATE ROTOR PLATE WITH ROTOR SHAFT CLEARANCE 0.001” (0.025 mm) SHIM SPACE (Dwg. TPD1275) 4. Coat each Vane (28) with a thin film of oil and insert a Vane into each of the rotor vane slots with the straight edge of the Vane outward. 5. Install the Cylinder Assembly (25) over the Vanes and Rotor making certain the Cylinder Alignment Pin (26) enters the hole in the face of the Front End Plate. 6. Stand the assembly on an arbor press table so that the rotor shaft on the front end plate end contacts the table. Press the Rear End Plate Assembly, bearing end trailing, onto the rotor shaft against the Cylinder. Make certain the Cylinder Alignment Pin (26) enters the hole in the face of the Rear End Plate. 7. Stand the assembly on a table with the Front End Plate Assembly upward. Assembly of the Motor 1. Using an arbor press and a piece of tubing that contacts the outer ring of the bearings, press the Front Rotor Bearing (30) into the Front End Plate (29) and the Rear Rotor Bearing (24) into the Rear End Plate (22). (Refer to Dwg. TPD1274.) 19 MAINTENANCE SECTION 22. Slide the Reverse Lever (2) onto the Reverse Valve, making certain the cast lug enters the notch on the face of the Reverse Valve Bushing. Secure the Lever to the Valve by inserting the Reverse Lever Retaining Pin (3). 8. Using an induction coil or oven, heat the Motor Housing until the motor opening is large enough to be placed over the Cylinder. At that time, install the Housing over the Cylinder and Front End Plate making sure the radial End Plate Alignment Pin (23) in the Rear End Plate enters the notch in the Motor Housing. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. Assembly of the Impulse Mechanism 1. Insert the long shaft of the Piston Stop (69) into the central opening of the O–ring Installer furnished with the Tool Kit (Part No. 1900P–99). Place the Piston Stop Seal (70) on the tapered end of the Installer and roll the Seal up the taper and into the groove on the large body of the Piston Stop. Repeat the procedure with the other Piston Stop and Seal. 2. When looking inside the central opening of the Liner Assembly (66), the internal wall has three holes on one side which do not extend through the wall. The opening on the end face of that wall is for the Torque Valve Piston (68). Install the Torque Valve Piston, large end trailing, into that opening. 3. Insert the Piston Stop Assist Spring (71) into the hole in the end face of the opposite wall. 4. Thread the Threaded Tee Wrench furnished with the Tool Kit into one of the Piston Stop Assemblies and using the Wrench to hold the Assembly, insert the Assembly into the opening against Piston. Mark this opening with a felt marker to indicate that it contains the Torque Valve Piston. 5. Unscrew the Wrench and in the same manner, install the other Piston Stop Assembly in the hole with the Spring. 6. Install the Rear Liner Cover Seal (72) in the annular groove on the face of the Rear Liner Cover (73). 7. Install the two Front Liner Cover Piston Seals (59) in the openings on the face of the Front Liner Cover (50). 8. Install the Seal Back–Up Ring (58) followed by the Drive Shaft O–ring (57) in the central opening in the face of the Front Liner Cover. 9. Insert the short round hub of the Drive Shaft (61) into the central opening of the Rear Liner Cover. 10. Insert a Blade (64) into one slot in the Drive Shaft. Install the Blade Springs (65) through the Drive Shaft and into the holes in the Blade. Place the remaining Blade on the Springs making certain the Springs enter the holes in that Blade. 11. Using finger pressure, compress the Springs with the Blades until the outer edges of the Blades are flush with the drive shaft surface. Capture the Blades in thisposition by installing the Liner Assembly, piston stop end trailing, over the Drive Shaft and against the Rear Liner Cover. Take all precautions necessary to prevent being burned by handling warm or hot parts. Allow the assembly to cool and install the Motor Case Cover Gasket (33) and Motor Case Cover (31). Secure the Cover to the Housing by installing the four Motor Case Cover Screws (34) and Lock Washers (35). Tighten each Screw between 45 and 50 in–lb (5.1 and 5.6 Nm) torque. Install the Exhaust Deflector (21) in the bottom of the handle of the Motor Housing (1) and tighten it between 20 and 25 ft–lb (27 and 34 Nm) torque. Thread the Inlet Bushing (20) into the bottom of the handle of the Motor Housing and tighten it between 30 and 35 ft–lb (40 and 47 Nm) torque. Install the Throttle Rod Seal (16) in the groove on the large hub of the Throttle Rod (15). Install the Throttle Valve Seal (13) in the groove on the large hub of the Throttle Valve (12). Slide the Throttle Valve, Valve Seal end first, onto the Throttle Valve Rod. Secure the Throttle Valve Assembly by installing the Valve Retaining Ring (14) in the small groove on the Throttle Valve Rod. Install the three Throttle Bushing Seals (11) in the grooves on the Throttle Bushing (10). Slide the Throttle Bushing Assembly onto the shaft of the Throttle Valve Rod and position the Trigger (17) on the same shaft. Install the Trigger Pin (18). Insert the assembled Trigger into the Housing. Make certain the widest end of the Trigger is nearest the motor bore and the narrowest portion of the Throttle Valve aligns with hole for the Throttle Retaining Pin (19). Install the Pin making certain it captures the Throttle Valve and secures the assembled Trigger. Align the detent hole in the Reverse Valve (5) with the hole inside the Reverse Valve Bushing (4) and slide the Valve into the Bushing until almost reaching the detent hole. Insert the Reverse Valve Detent Spring (7) and Reverse Valve Detent Ball (6) into the hole and while compressing the Spring with the Ball, slide the Valve completely into the Bushing. Using snap ring pliers, install the Reverse Valve Retainer (8). 20 MAINTENANCE SECTION 12. 13. 14. 15. 16. 17. 18. After assembling the tool, check the torque output with a torque tester or pulse counter. If the output is not acceptable, adjust the torque output as instructed in the section TORQUE ADJUSTMENT. If the output is acceptable, proceed as follows: a. Using a hex wrench, remove the four Hammer Case Cap Screws (40) and Lock Washers (41). Lift the Hammer Case (36) off the Motor Housing (1) over the Drive Shaft. Remove the Hammer Case Gasket (39). b. Lift the assembled mechanism off the Rotor (27). c. Grasp the flats of the Housing (49) in vise jaws with the output end of the Drive Shaft downward. d. Insert the pins of the Spanner Plug from the No. 1900P–99 Tool Kit into two holes in the Housing Cap (74). Using a wrench on the plug, unscrew and remove the Housing Cap from the Housing. This is a left–hand thread, rotate the plug counterclockwise to loosen the Cap. e. Apply thread sealant to the threads of the Cap and using the Spanner Plug furnished with the Tool Kit and a torque wrench, install the Housing Cap, castellated end leading. This is a left–hand thread; rotate the wrench counterclockwise to tighten the Cap. Tighten the Cap on model 2400P between 173 and 188 ft–lb (235 and 254 Nm) torque and on model 3000P between 186 and 200 ft–lb (252 and 272 Nm) torque. f. Position a new Hammer Case Gasket (39) on the Motor Housing and install the assembled mechanism on the rotor shaft. g. Place the Hammer Case Cover over the Drive Shaft against the Housing and Gasket. Install the four Hammer Case Cap Screws and Lock Washers. Tighten each Screw between 45 an 50 in–lb (5.1 and 5.6 Nm) torque. h. Install the Rubber Housing Boot on the tool. This installation can be accomplished more easily by aligning the compressed Blades with the webs at the narrowest portion of the opening. Keeping the Blades on the web allows them to slide the length of the Liner without interference. Insert the hex end of the Rear Liner Cover into the Disassembly Arbor from the Tool Kit and stand it on a workbench with the Drive Shaft upward. Install the Front Liner Cover Assembly over the Drive Shaft and against the Liner. Make certain the Torque Adjustment Screw (51) aligns with the proper piston stop opening that was marked during assembly. Install the two Liner Cover Seals (60) in the grooves inside the Liner Housing (49) near the end with the external wrench flats. Place the Liner Housing, Seal end trailing, over the assembled Liner. Make certain the notch in the trailing end face of the Housing aligns with the Oil Plug (54) in the Front Liner Cover. Use the Pressing Sleeve from the Tool Kit to press the Housing over the Seals and into position. Do not Damage the Seals during installation. Grasp the flats of the Liner Housing in vise jaws and using the Spanner Plug furnished with the Tool Kit and a torque wrench, install the Housing Cap, castellated end leading. This is a left–hand thread; rotate the wrench counterclockwise to tighten the Cap. Tighten the Cap on model 2400P between 173 and 188 ft–lb (235 and 254 Nm) torque and on model 3000P between 186 and 200 ft–lb (252 and 272 Nm) torque. Make certain the Drive Shaft rotates freely and then fill the mechanism with fluid and reassemble the tool as instructed in the section, CHANGING THE MECHANISM FLUID. 21 NOTES 22 NOTES 23
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Ingersoll-Rand 2400P Operation and Maintenance Manual

Categoría
Herramientas eléctricas
Tipo
Operation and Maintenance Manual
Este manual también es adecuado para

en otros idiomas