CARLO GAVAZZI DPC02DM23 El manual del propietario

Tipo
El manual del propietario

Este manual también es adecuado para

DPC02DMXX
TRMS 3-Phase, 3-Phase+N monitoring relay
3-Phasen,multifunktionsrelais,echter effektivwert
Relais de contrôle 3-Phases,3-Phases+N TRMS
Relé de control de tensión trifásica
Relé trifásico, medida TRMS 3 Fases + Neutro
Sand rms-målende relæ, 3-faset, 3-faset+N
Installation instructions
Installationshinweise
Notice d’installation
Instrucciones de instalación
Istruzioni per l’installazione
Installationsvejledning
Mounting and installation by skilled people only!
Montage und Installation nur durch Fachpersonal!
Montage et installation par des personnes habilitées seulement!
El montaje e instalación ha de realizarlo solo personal con experiencia!
Il montaggio e l’installazione va eseguito da parte di personale addestrato!
Montering og installation må kun foretages af faguddannede personer!
ENGLISH DEUTSCH FRANÇAIS ESPA—OL ITALIANO DANSK
j
Connections
Connect the 3-phase
power supply and the neu-
tral (if present) taking care
of the sequence. Connect
the relay outputs according
to the ratings. Automatic
screwdriver can be used
(max torque 0.5 Nm).
Keep power OFF
while connecting!
k
Setting of function and
input range
Adjust the input range set-
ting the DIP switches 3
and 4. Select the desired
function setting the DIP
switches 1 to 2 and 5 to 6.
To access the DIP switch-
es open the plastic cover
using a screwdriver as
shown on the left.
SW1 selects the mode of
the relay outputs: 2xSPDT
(relays operate independ-
ently each connected to a
single set point) or 1xDPDT
(relays operate together)
SW2 selects the measuring
mode: phase-phase (mon-
itoring only delta voltages)
or phase-neutral voltage
(monitoring both delta and
star voltages). SW5 sets
the nominal frequency
value (ON: 60 Hz, OFF: 50
Hz).
SW6 selects the frequency
setpoint range (2 or 15 Hz).
Do not open the
DIP-switches cover
if the Power Supply
is ON
l
Mechanical mounting
Hang the device to the
DIN-Rail being sure that
the spring closes. Use a
screwdriver to remove the
product as shown in figure.
j
Anschlüsse
Das Drehstromkabel und
das Erdkabel (falls vorhan-
den) unter Einhaltung der
Reihenfolge anschliessen.
Den Relais-Ausgang ent-
sprechend den angege-
benen Belastungswerten
anschliessen.
Autometischer Schrauben-
dreher kann benutzt werden
(Drehmoment max. 0,5 Nm).
Achten Sie beim
Anschluß auf Span-
nungsfreiheit!
k
Einstellung der
Eingangsleistung sowie
der Funktion.
Die gewünschte Leistung
mit Hilfe der DIP-Schalter
3 und 4 einstellen. Die
Funktion mit Hilfe der DIP-
Schalter 1 bis 2 und 5 bis
6 auswählen. Um Zugang
zu den DIP-Schaltern zu
bekommen, die Klappe mit
Hilfe eines Schraubenzie-
hers - wie in der Illustration
gezeigt - öffnen. Mit SW1
wird die Funktionsweise der
Relaisausgänge gewählt:
2xSPDT (die Relais funk-
tionieren unabhängig von-
einander, jedes ist an eine
einzelne Leistung ange-
schlossen) oder 1xDPDT
(die Relais funktionieren
zusammen). Mit SW2 wird
die Masseinheit gewählt:
Phase-Phase (kontrolliert
lediglich die verketteten
Spannungen) oder aber
Phase-Mittelleiter (kontrol-
liert sowohl die verketteten
als auch die Sternspan-
nungen). Mit DIP-Schalter
SW5 ist die Netzfrequenz
zu wählen (EIN: 60 Hz,
AUS: 50 Hz).
Mit SW6 wird der
Grenzwertbereich der
Netzfrequenz eingestellt (2
oder 15 Hz).
Achtung! Gerät vor
dem Öffnen der DIP-
Schalterabdeckung
spannungsfrei
Schalten
l
Montage
Befestigen Sie das Relais
auf der DIN-Schiene und
achten Sie darauf, daß die
Befestigungsfeder ein-
gerastet ist. Benutzen Sie
einen Schraubendreher,
um das Relais wieder zu
entfernen, wie im neben-
stehenden Bild gezeigt.
j
Connections
Connecter les 3 phases
d’alimentation et le neutre
(si présent) en prenant
soin de respecter l’ordre
des phases. Connecter la
sortie relais selon le sché-
ma. Les tournevis automa-
tiques peuvent être utilisés
(couple de serrage max 0,5
Nm).
Couper l’alimenta-
tion lors des raccor-
dements!
k
Paramétrage de la fonc-
tion et de la gamme de
mesure.
Ajuster la gamme de mesu-
rer en activant les micro
commutateurs 3 et 4.
Sélectionner la fonction
désirée en activant les
micro commutateurs 1 à 2
et 5 à 6. Pour accéder aux
micro commutateurs ouvrir
le cache plastique en utili-
sant un tournevis comme
indiqué sur la gauche.
SW1 sélectionne le mode
de sortie relais: 2xSPDT
(relais fonctionnant indé-
pendamment chacun étant
lié à un seuil) ou 1xDPDT
(relais associés mécani-
quement). SW2 sélectionne
le mode de mesure: : phase
- phase (surveillance des
tensions composées) ou
phase - neutre (surveil-
lance des tensions com-
posées et également des
tensions simples). Le DIP
switch SW5 règle la fré-
quence nominale (à 60 Hz
en position ON et à 50 Hz
en position OFF). Le DIP
switch SW6 sélectionne la
gamme de fréquences de
consigne (2 ou 15 Hz).
Ne pas ouvrir le
convercle des micro
commutateurs si
l’appareil est sous
tension.
l
Montage mécanique
Accrocher l’appareil sur le
rail DIN en s’assurant que
l’agrafe est positionnée.
Utiliser un tournevis pour
retirer le produit tel indiqué
sur le schéma.
j
Conexiones
Conectar las tres fases de
alimentación y el neutro
(si esta disponible) tenien-
do en cuenta la secuen-
cia de fases. Conectar el
relé de salida de acuerdo
a la carga indicada. Puede
usarse un destornillador
automático (max. par 0,5
Nm).
Desconecte la
ali-mentación antes
de realizar las cone-
xio-nes!
k
Ajuste del rango de ent-
rada y de la función
Ajustar el rango de entra-
da con los DIP-switches
3 y 4. Seleccionar la fun-
ción deseada con los DIP-
switches 1 a 2 y 5 a 6. Para
acceder a los DIP switches
abrir la tapa de plástico
como indica la figura de la
izquierda.
SW1 selecciona el modo
de funcionamiento de la
salida del relé: 2xSPDT
(Los relés trabajan inde-
pendientemente, cada
uno referido a un punto
de ajuste) o 1xDPDT (Los
relés trabajan conjunta-
mente). SW2 selecciona el
modo de medida: Tensión
entre fases (control solo de
tensiones en triángulo) o
tensión entre fase-neutro
(Control de conexiones en
estrella o triángulo). Con
SW5 se ajusta el valor
nominal de la frecuencia
(ON: 60 Hz, OFF: 50 Hz).
Con SW6 se selecciona el
rango de frecuencia (2 o
15 Hz)
No abrir la tapa de
los DIP-switches
bajo tensión de ali-
mentación
l
Montaje Mecánico
Sujetar el equipo al rail DIN
asegurando que las bridas
de sujección esten cerra-
das. Use un destornillador
para manipular el equipo
como indica la figura.
j
Collegamenti
Collegare la rete trifase
e il neutro (se presente)
rispettando la sequen-
za. Collegare l’uscita relè
secondo i valori di carico
indicati. La coppia massi-
ma in caso di uso di avvi-
tatori automatici è 0.5 Nm.
Staccare l’alimenta-
zione prima di col-
legare lo strumento!
k
Messa a punto della por-
tata d’ingresso e della
funzione.
Selezionare la portata desi-
derata attraverso i DIP swi-
tch 3 e 4. Selezionare la
funzione attraverso i DIP
switch da 1 a 2 e da 5
a 6. Per accedere ai DIP
switch aprire lo sportellino
usando un cacciavite come
mostrato in figura.
SW1 seleziona il modo di
funzionamento delle uscite
relè: 2xSPDT (i relè funzio-
nano indipendentemente,
ciascuno collegato ad una
singola portata) o 1xDPDT
(i relè funzionano insieme).
SW2 seleziona il tipo di
misura: fase-fase (controlla
solo le tensioni concate-
nate) oppure fase-neutro
(controlla sia le tensioni
concatenate che quelle
stellate). SW5 seleziona il
valore nominale di frequen-
za (ON: 60 Hz, OFF: 50 Hz).
SW6 seleziona la gamma
di misura della frequenza (2
o 15 Hz).
Non aprire lo spor-
tello DIP-switch se
l’alimentazione è
collegata!
l
Montaggio
Agganciare lo strumento
alla guida DIN verificando
la chiusura della molla. Per
rimuovere il prodotto dalla
guida usare un cacciavite
come mostrato in figura.
j
Tilslutninger
Tilslut den 3-fasede for-
sy-ningsspænding samt
nul (hvis den er til stede),
vær opmærksom på kor-
rekt fasefølge. Tilslut
relæudgangen i over-
ensstemmelse med data.
Automatskruetrækker kan
anvendes (max. moment
0,5 Nm).
Forsyningen skal
være koblet fra,
mens forbindelserne
etableres!
k
Indstilling af funktions-
og indgangsområde
Indstil indgangsområdet
med DIP-switch 3 og 4.
Vælg det ønskede funk-
tionsområde med DIP-
switch’ene 1 til 2 og 5 til
6. For at få adgang til DIP-
switch’ene åbnes plastik-
dækslet med en skruetræk-
ker som vist til venstre.
SW1 vælger funktionen
af relæudgangene: 2 x
SPDT (relæerne fungerer
uafhæn-gigt med hver sit
setpunkt) eller 1 x DPDT
(relæerne fungerer sam-
men). SW2 vælger måle-
metode: Fase-fase (måler
kun spændingerne i tre-
kant) eller fase-nul (måler
spændingerne i både tre-
kant og stjerne). Med SW5
indstilles den nominelle fre-
kvensværdi (aktiveret: 60
Hz, deaktiveret: 50 Hz).
Med SW6 vælges indstil-
lingsområdet for frekvens
(2 eller 15 Hz).
Beskyttelsesdæk-
slet over DIP-
switches må ikke
fjernes, når forsy-
ningsspændingen er
tilsluttet
l
Mekanisk montering
Monter systemet på DIN-
skinnen, og sørg for, at fje-
deren låser. Afmontering af
systemet foretages ved at
anvende en skruetrækker
som vist i figuren.
DPC02 V3 / code 8021863/121218 http://www.carlogavazzi.com/ CARLO GAVAZZI
ON: PH-N
OFF: PH-PH
ON/ON:
M23 - 208 VAC
M48 - 380 VAC
M49 - 440 VAC
M69 - 600 VAC
ON/OFF:
M23 - 220 VAC
M48 - 400 VAC
M49 - 440 VAC
M69 - 600 VAC
OFF/ON:
M23 - 230 VAC
M48 - 415 VAC
M49 - 480 VAC
M69 - 690 VAC
OFF/OFF:
M23 - 240 VAC
M48 - 415 VAC
M49 - 480 VAC
M69 - 690 VAC
ON: 60 Hz
OFF: 50Hz
ON: 2 Hz
OFF: 15 Hz
L2 L3L1
L1
L2
L3
N
N
25
26 28
15
16 18
L2 L3L1
L1
L2
L3
25
26 28
15
16 18
N
N
L1
L2
m<3
L1
L2
m<3
ON: 2xSPDT
OFF: 1xDPDT
m
Start-up and adjustment
Check if the input range
is correct. Turn the power
ON. The two-colors LED
is ON (green or red color).
Adjust the upper and
lower voltage level using
the upper and the centre
left knobs. Adjust the fre-
quency window on relative
scale using the centre right
knob and, using the lower
knobs, set the delays time
(0,1 to 30 s). DPC02 oper-
ates when all 3 phases are
present at the same time
in the proper sequence, the
voltage value is withing the
upper and lower set limits
and the frequency value is
within a symmetrical win-
dow across the nominal
frequency.
n
Note
The packing material
should be kept for redeliv-
ery in case of replacement
or repair.
o
Terminals
Power supply
Relay 1 output
Relay 2 output
Each terminal can accept
up to 2 x 2.5 mm2 wires.
q
Responsibility for disposal
The product must be dis-
posed of at the relative
recycling centres specified
by the government or local
public authorities. Correct
disposal and recycling will
contribute to the preven-
tion of potentially harm-
ful consequences to the
environment and persons.
m
Einschalten und
Einstellungen
Die Richtigkeit der
Leistung kontrollieren. Dem
Instrument Strom zufüh-
ren. Die beiden farbigen
LED leuchten (grün oder
rot). Stellen Sie den oberen
und den unteren Grenzwert
der Spannung mit dem
Drehknopf oben links bzw.
dem Drehknopf in der Mitte
links ein. Stellen Sie die
Breite des Frequenzfen-
sters mit dem mittleren
Drehknopf links auf einer
relativen Skala ein. Wählen
Sie die Alarmverzögerung
(0,1 bis 30 s) mit den unte-
ren Drehknöpfen.
Das DPC02 zieht an, wenn
die 3 Außenleiterspannun-
gen anliegen und die rich-
tige Phasenfolge haben,
die Spannung innerhalb
der unteren und obe-
ren Grenzen liegt und die
Netzfrequenz in einem
symmetrischen Fenster
mit der Netzfrequenz als
Mittenfrequenz liegt.
n
Bemerkungen
Heben Sie bitte die
Originalverpackung für
eventuelle Rücksendungen
an die Serviceabteilung auf.
o
Anschlußklemmen
Betriebsspannung
Erste Relaisausgang
Zweite Relaisausgang
Klemmenanschluß bis max.
2 x 2,5 mm2 je Klemme.
q Verantwortlichkeit für
Entsorgung
Dieses Produkt muss
bei einem geeigneten
von der Regierung oder
lokalen öffentlichen
Autoritäten anerkannten
Recyclingbetrieb entsorgt
werden. Ordnungsgemäße
Entsorgung und Recycling
tragen zur Vermeidung
möglicher schädlicher
Folgen für Umwelt und
Personen bei.
m
Mise en service et réglage
Vérifier si la gamme de
mesure est correcte. Mettre
sous tension. La LED bico-
lore (rouge ou verte) est
allumée. Régler la butée de
tension haute ou basse à à
l’aide des boutons du bas
et du centre, respective-
ment. Régler la gamme de
fréquences en échelle rela-
tive à l’aide du bouton cen-
tral droit. Régler les tem-
porisations (0,1 to 30 s).à
l’aide des boutons du bas.
DPC02 opère lorsque les
trois phases sont simulta-
nément présentes dans la
séquence correcte, que la
tension est comprise entre
les butées haute et basse
et que la fréquence se situe
à l’intérieur d’une fenêtre
symétrique à la fréquence
nominale para rapport à la
nominale.
n
Note
L’emballage doit être
conservé lors du retour du
matériel en cas de rempla-
cement ou de réparation.
o
Borniers
Alimentation
Sortie relais (1)
Sortie relais (2)
Chaque borne peut accep-
ter des câbles 2 x 2,5 mm2.
q
Responsabilité en matiè-
re d’élimination
Éliminer selon le tri sélec-
tif avec les structures de
récupération indiquées par
l’État ou par les organis-
mes publics locaux. Bien
éliminer et recycler aidera à
prévenir des conséquences
potentiellement néfastes
pour l’environnement et les
personnes.
m
Ajuste y puesta en marcha
Chequear que el rango
de entrada es correcto.
Alimentar el equipo. El LED
(verde o rojo) se encien-
de. Ajustar el nivel máxi-
mo y mínimo de tensión
con los potenciómetros
de la izquierda superior y
central. Ajustar la banda
de frecuencia en la escala
relativa con el potencióme-
tro central de la derecha
y con los potenciómetros
inferiores, ajustar los retar-
dos de tiempo (0,1 a 30
s). El equipo DCP02 opera
cuando las 3 fases están
presentes al mismo tiempo
en la secuencia correcta, el
valor de tensión está den-
tro de los límites estableci-
dos y el valor de frecuencia
está dentro de la banda de
frecuencia nominal selec-
cionada.
n
Nota
El embalaje deberá ser
guardado para reenviar el
equipo en caso de repara-
ción o cambio.
o
Terminales
Alimentación
Relé 1 de salida
Relé 2 de salida
Cada terminal admite 2
cables de 2,5 mm2.
q
Responsabilidad de elimi-
nación
Eliminar mediante recogida
selectiva a través de las
estructuras de recogida
indicadas por el gobierno
o por los entes públicos
locales. La correcta elimin-
ación y el reciclaje ayudarán
a prevenir consecuencias
potencialmente negativas
para el medioambiente y
para las personas.
m
Accensione e regolazione
Controllare la correttezza
della portata. Alimentare lo
strumento. Il LED bicolore
si accende (verde o rosso).
Regolare i valori di sovra e
sotto tensione utilizzando
le manette in alto e centra-
le nella parte sinistra della
facciata dello strumento.
Regolare le finestra di fre-
quenza usando la manetta
centrale di destra e, usan-
do quella più in basso,
selezionare i tempi di ritar-
do (da 0,1 a 03 s). Il DPC02
si attiva quando tutte 3 le
fasi sono presenti con la
sequenza corretta, il valore
della tensione è compre-
so tra i valori massimo e
minino impostati e il valore
di frequenza è compreso
all’interno di una finestra
simmetrica rispetto al valo-
re nominale di frequenza.
n
Nota
Conservare l’imballo origi-
nale in caso di sostituzione
o riparazione.
o
Terminali di collegamento
Alimentazione
Prima uscita relè
Seconda uscita relè
Ad ogni morsetto posso-
no essere collegati 2 fili di
2,5 mm2.
q
Responsabilità di smalti-
mento
Smaltire con raccolta dif-
ferenziata tramite le strut-
ture di raccolte indicate
dal governo o dagli enti
pubblici locali. Il corretto
smaltimento e il riciclaggio
aiuteranno a prevenire con-
seguenze potenzialmente
negative per l’ambiente e
per le persone.
m
Opstart og justering
Kontroller, at indgangs-
området er korrekt. Tilslut
forsyningsspænding.Den
2-farvede lysdiode er akti-
veret (grøn eller rød farve).
Juster det øvre og nedre
spændingsniveau ved
hjælp af den øverste og den
midterste venstre knap.
Juster frekvensvinduet på
relativ skala ved hjælp af
den midterste højre knap,
og indstil forsinkelsesperio-
den ved hjælp af de neder-
ste knapper (0,1 til 30 sek.).
DPC02 trækker, når alle tre
faser er til stede samtidig
i korrekt rækkefølge, når
spændingsværdien ligger
mellem den øvre og den
nedre grænseværdi, og
når frekvensværdien ligger
inden for et symmetrisk
vindue hen over den nomi-
nelle frekvens.
n
Bemærk
Gem emballagen til brug
ved returnering i forbindel-
se med erstatningsleveran-
ce eller reparation.
o
Terminaler
Spændingsforsyning
Relæ 1 udgang
Relæ 2 udgang
Hver terminal kan accepte-
re kabel op til 2 x 2,5 mm2.
q
Ansvar for bortskaffelse
Produktet skal bortskaffes
på en lokal, godkendt
genbrugsstation. Korrekt
bortskaffelse og genbrug
vil bidrage til at mindske
eventuelle skadelige kon-
sekvenser for miljøet,
mennesker og dyr.
DPC02 V3 / code 8021863/121218 http://www.carlogavazzi.com/ CARLO GAVAZZI
DPC02
L1-L2-L3-N
15-16-18
25-26-28
General warnings:
- Read carefully the present instruction manual, If the device is used in a manner not specified by the
manufacturer the protection function may be impaired.
- All operations concerning installation, or unmounting, of device or modules shall be carried out by
qualified personnel and after having disconnected all power sources.
- A readily accessible overcurrent protection ( fuse or circuit breaker) shall be incorporated in the bu-
ilding installation wiring.
UL Notes:
- Use 60 or 75°C copper (CU) conductor and wire size No. 30-14 AWG, stranded or solid (DIN models
only)
- Terminal tightening torque of 4.4Lb-In” (DIN models only)
- Being these devices Overvoltage Category III they are: “For use in a circuit where devices or system,
including filters or air gaps, are used to control overvoltages at the maximum rated impulse withstand
voltage peak of 6.0 kV. Devices or system shall be evaluated using the requirements in the Standard
for Transient Voltage Surge Suppressors, UL 1449 and shall also withstand the available short circuit
current in accordance with UL 1449
- The devices shall be installed in a pollution degree 2 environment (or better).
Avertissements généraux:
- Lire attentivement ce manuel d’instructions. Si le dispositif est utilisé d’une manière autre que celle spècifièe par le fabricant,
la fonction de protection peut être altérée.
- Toutes les opérations concernant l’installation, le démontage du dispositif et des modules doivent être effectuées par du
personnel qualifié et uniquement après avoir déconnecté les sources d’alimentation et de puissance.
- Une protection contre les surintensités facilement accessible (fusible ou disjoncteur) doit être intégrée au câblage d’installa-
tion du bâtiment.
Notes UL:
- Utilisez un conducteur en cuivre (CU) à 60 °C ou à 75 °C, calibre de fil AWG30 à AWG14 (0.06mm2 à 2.1mm2) Toronnè ou
solide (modèles DIN uniquement).
- Couple de serrage des bornes de 4.4Lb-In (0.5Nm), (modèles DIN uniquement).
- S’agissant de ces dispositifs de catégorie de surtension III, ils sont: «Pour une utilisation dans un circuit où des dispositifs ou
un système, y compris des filtres ou des éclateurs, sont utilisés pour contrôler les surtensions au maximum de la tension de
tenue nominale aux impulsions de 6,0 kV. Les appareils ou systèmes doivent être évalués conformément aux exigences de la
norme UL 1449 pour les limiteurs de surtension transitoire certifiés pour le Canada, et doit également résister à court courant
du circuit conformément à la norme UL 1449.
- Le dispositif doit être installé dans un environnement de degré de pollution 2 (ou mieux) et seulement par des gens qualifiés.
  • Page 1 1
  • Page 2 2

CARLO GAVAZZI DPC02DM23 El manual del propietario

Tipo
El manual del propietario
Este manual también es adecuado para