Broan RDFU Guía de instalación

Categoría
Ventiladores domésticos
Tipo
Guía de instalación

Este manual también es adecuado para

RDFU
Premium
Radiation Damper
INSTALLATION GUIDE
READ AND SAVE THESE INSTRUCTIONS
Installer: leave this guide with homeowner.
Register your product online at: www.broan.com/register or www.nutone.com/register.
Easy installation
© 2017 Broan
RDFU – Installation Guide
Page 2
For use with 1, 2, or 3-Hour-Rated Floor-Ceiling and Roof-Ceiling Designs.
Flat Ceiling / Horizontal Mount Only.
For use with the following ventilation fan models:
Broan QT130E, QT130LE, QT140E, QT140LE, QTXE150, QTXE150FLT, RB80, RB80L, RB80L1,
RB110, RB110L, RB110L1, XB50, XB80, XB110, XB50L, XB50L1, XB80L, XB80L1, XB110L,
XB110L1, XB110H, XB110HL, XB110HL1, ZB80, ZB110, ZB80L, ZB80L1, ZB110L, ZB110L1,
ZB110H, ZB110HL, ZB110HL1, ZB80M, ZB110M, ZB80ML, ZB80ML1, ZB110ML, ZB110ML1
NuTone QTN130E, QTN130LE1, QTXEN150, QTXEN150FLT, RN80, RN80L, RN110, RN110L,
XN50, XN80, XN110, XN50L, XN80L, XN110L, XN110H, XN110HL, ZN80, ZN110, ZN80L, ZN110L,
ZN110H, ZN110HL, ZN80M, ZN110M, ZN80ML, ZN110ML
Twin City T080E, T110E, T150LP
Usage
SEE DETAILS ON
UL CLASSIFICATION
MARKING ON PRODUCT
Prepare Fan
The following steps are best performed on a work surface
before fan installation. Protect counter tops by placing
corrugated sheet under the fan.
1. Install (2) #8 x ½” HEX HEAD SHEET METAL
SCREWS (A) supplied in fan parts bag.
2. Slide (4) MOUNTING BRACKETS (B) into slots on
four sides of RADIATION DAMPER EXTENSION
FRAME (C). Make sure they snap into place and are
securely engaged after assembly.
3. Center the radiation damper over the fan housing.
Make sure NOTCH (D) is correctly positioned relative
to the DUCT CONNECTOR OPENING (E).
4. Align radiation damper brackets with holes in the fan
housing. Secure brackets to fan housing with (4) #8
X 3/8” SHEET METAL SCREWS (F) (Supplied in
radiation damper parts bag.)
Steps 5 through 9:
Lighted Fans, Humidity-Sensing Fans, or
Motion Sensing Fans ONLY.
For fans not equipped with a light, a humidity sensor or a
motion sensor: Skip to Step 10.
5. Make lead wires longer. Purchase jumper kit model
RDJUMPU or RDJUMPU1 from your local Broan
dealer or distributor.
Each kit contains:
1 - Jumper for lighted fan models
1 - Jumper for sensor fan models
6a. For fans equipped with incandescent or fluorescent
lights, connect one end of the LIGHTING JUMPER
(G) to mating connector in the fans wiring box.
6b. For fans equipped with LED lights, connect one end
of the LIGHTING JUMPER (G) to mating connector
from LED DRIVER (H).
6c. For fans equipped with humidity or motion sensors,
connect one end of the SENSOR JUMPER (I) to
mating connector in the fans wiring box.
7. Route JUMPER(S) (G) (I) towards the NOTCH (D) in
the damper frame.
8. Press jumper wires into PLASTIC SPLIT TUBE
INSULATOR (J) (supplied in damper parts bag).
Push plastic split tubing into NOTCH (D) opening.
9. Align tab on CABLE CLAMP (K) with mating slot in
damper extension. Secure clamp with supplied #8 x
3/8” SHEET METAL SCREW (F).
C
A
RDFU – Installation Guide
Page 3
I *
G
B
C
F
D
E
F
K
J
FANS WITH INCANDESCENT
OR FLUORESCENT LIGHTS
I * Jumper for Motion or
Humidity-Sensing units only.
I *
G
H
FANS WITH LED LIGHTS
I * Jumper for Motion or
Humidity-Sensing units only.
RDFU – Installation Guide
Page 4
L
snap!
snap!
L
M
Step 10:
RB, XB, ZB, RN, XN, ZN Models ONLY
10. Slide MOUNTING FRAME (L) onto fan housing. Pull
frame up around housing until it snaps into place.
Secure mounting frame to fan housing with (2) #8
X 3/8” FLAT HEAD SHEET METAL SCREWS (M)
supplied in the fan parts bag.
Step 11:
QT Models ONLY
11. Attach MOUNTING CHANNELS (N) to housing using
SCREWS (O) supplied in fan parts bag.
Insert SLIDE BRACKETS (P) into mounting channels.
N
O
P
SCREW FROM
PARTS BAG
INSERT
TAB INTO
SLOT IN
HOUSING
TOP AND BOTTOM FLANGES
REMAIN OUTSIDE OF HOUSING
12. Install 6” DUCT CONNECTOR (Q) to fan housing and
secure with screw supplied in fan parts bag.
Q
RDFU – Installation Guide
Page 5
Install Fan / Radiation Damper
15. Refer to instructions supplied with the fan for various
electrical wiring configurations.
16. Install MASK (R) supplied with the fan to protect damper
and fan from drywall spray, construction dust, etc.
Finish Installation
17. Finish ceiling around radiation damper opening. Ceiling
opening must be no larger than the outside of the
radiation damper.
18. Remove MASK (R) from housing.
R
1
2
1
2
MINIMUM 12
GAUGE STEEL
WIRE (3MM)
(4)
SLIDING
HANGER
BARS
#8 (M4) SHEET METAL
SCREWS OR ¼” DIAMETER
BOLTS WITH NUTS
(4)
Install Fan / Radiation Damper In Ceiling
MAKE SURE FINISHED CEILING IS FLUSH WITH
BOTTOM EDGE OF RADIATION DAMPER.
13. If the fan assembly is hung from the structure above,
MINIMUM 12 GAUGE STEEL WIRE (3MM) must be
used to suspend the fan. Use one wire on each side of
fan and secure to mounting channels as shown.
14. If the fan is directly mounted to adjacent ceiling
structure, use #8 (M4) SHEET METAL SCREWS OR
¼” DIAMETER BOLTS WITH NUTS to fasten SLIDING
HANGER BARS. Sliding hanger bars are provided to
allow for accurate positioning of fan between ceiling
members.
RDFU – Installation Guide
Page 6
Service Feature For Fans
Limited Warranty
Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its
workmanship for a period of one (1) year from the date of original purchase.
The limited warranty period for any replacement parts provided by the Company and for any Products repaired or replaced under this limited warranty shall be the remainder of the original warranty period.
This warranty does not cover speed controls, fluorescent lamp starters, tubes, halogen and incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and other accessories for ducting that may be purchased separately and
installed with the Product. This warranty also does not cover (a)normal maintenance and service, (b)normal wear and tear, (c)any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident,
improper or insufficient maintenance, storage or repair (other than repair by the Company), (d)damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (e)any Product that has been
moved from its original point of installation, (f)damage caused by environmental or natural elements, (g)damage in transit, (h)natural wear of finish, (i)Products in commercial or nonresidential use, or (j)damage caused by fire,
flood or other act of God. This warranty covers only Products sold to original consumers in the United States by the Company or U.S. distributors authorized by the Company.
This warranty supersedes all prior warranties and is not transferable from the original consumer purchaser.
No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your sole remedy for defective products. The foregoing warranties are exclusive and in lieu of any other warranties, express or implied. THE
COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. To the extent that applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the period specified for the express warranty
above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it and shall not be
construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law, but if any provision is held to be prohibited or invalid, such provision shall be ineffective
only to the extent of such prohibition or invalidity, without invalidating the remainder of such provision or the other remaining provisions of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without charge, any Product or part thereof, to the extent the Company finds it to be covered
by and in breach of this limited warranty under normal use and service. The Company will ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all costs for removal, reinstallation and
shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send the Product or part to the Company, as instructed by the Company, you must properly pack the Product
or part—the Company is not responsible for damage in transit. The Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the warranty repair or replacement process. Such
Products and parts will be comparable in function and performance to an original Product or part and warranted for the remainder of the original warranty period.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT THE COMPANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED
WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION
WITH THE PRODUCT, ITS USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights,
which vary from state to state.
This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main facility and does not include the cost of field service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute a waiver of such terms, limitations or exclusions, nor will such assistance extend
or revive the warranty.
The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective Product, except for those incurred with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a)notify the Company at the address or telephone number stated below within seven (7)days of discovering the covered defect, (b)give the model number
and part identification and (c)describe the nature of any defect in the Product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot provide a copy of the original
written limited warranty, then the terms of the Company’s most current written limited warranty for your particular product will control.The most current limited written warranties for the Company’s products can be found at www.
broan.com .
Broan 926 West State Street Hartford, WI 53027 www.broan.com 800-637-1453
If your ventilation fan needs service, the inner damper can
be removed from the outer frame without disturbing the
surrounding ceiling material.
Install Grille
1
2
Step 19:
Lighted Fans ONLY.
19. Attach connector from the LIGHT JUMPER WIRE (G)
to mating connector(s) from the grille.
S
T
G
I
Remove the grille and disconnect all electrical connections
from the grille.
Remove (4) screws, then lower the inner damper to access
ventilation fan. Replace the inner damper before operating fan.
Step 20:
Humidity-Sensing Fans and Motion Sensing Fans ONLY.
20. Connect SENSOR JUMPER WIRE (I) into the sensors
connector located on the grille.
21. Squeeze 2 GRILLE SPRINGS (S) and slide into tabs
on the radiation damper frame. Push GRILLE (T) until
it’s tight against ceiling surface.
If additional clearance is required between ceiling and
grille, replace grille springs with longer ones (provided
in parts bag).
99045951B
RDFU
Clapet anti-rayonnement
de qualité supérieure
GUIDE D’INSTALLATION
LISEZ CES DIRECTIVES ET CONSERVEZ-LES
Installateur : veuillez laisser ce guide au propriétaire.
Enregistrez votre produit en ligne sur : www.broan.com/register ou www.nutone.com/register.
Installation facile
© 2017 Broan
RDFU – Guide d’installation
Page 8
À utiliser dans les planchers/plafonds et toits/plafonds classés résistants au feu 1, 2 ou 3 heures.
Plafond plat/montage horizontal seulement.
À utiliser avec les modèles de ventilateurs d'aération suivants:
Broan QT130E, QT130LE, QT140E, QT140LE, QTXE150, QTXE150FLT, RB80, RB80L, RB80L1,
RB110, RB110L, RB110L1, XB50, XB80, XB110, XB50L, XB50L1, XB80L, XB80L1, XB110L,
XB110L1, XB110H, XB110HL, XB110HL1, ZB80, ZB110, ZB80L, ZB80L1, ZB110L, ZB110L1,
ZB110H, ZB110HL, ZB110HL1, ZB80M, ZB110M, ZB80ML, ZB80ML1, ZB110ML, ZB110ML1
NuTone QTN130E, QTN130LE1, QTXEN150, QTXEN150FLT, RN80, RN80L, RN110, RN110L,
XN50, XN80, XN110, XN50L, XN80L, XN110L, XN110H, XN110HL, ZN80, ZN110, ZN80L, ZN110L,
ZN110H, ZN110HL, ZN80M, ZN110M, ZN80ML, ZN110ML
Twin City T080E, T110E, T150LP
Utilisation
VOIR LES DÉTAILS
DU MARQUAGE DE
CLASSIFICATION UI SUR
LE PRODUIT
Préparation du ventilateur
Ces étapes seront mieux réalisées sur une surface de
travail avant d'installer le ventilateur. Protégez les comptoirs
en plaçant du carton ondulé sous le ventilateur.
1. Installez (2) VIS À TÔLE À TÊTE HEXAGONALE
N°8 X ½PO (A) fournies dans le sac de pièces
duventilateur.
2. Faites glisser les (4) SUPPORTS DE MONTAGE (B)
dans les fentes sur les quatre côtés du CADRE DE
RALLONGE DU CLAPET ANTI-RAYONNEMENT (C).
Assurez-vous qu’ils s’enclenchent en place et sont
fermement assujettis après l’assemblage.
3. Centrez le clapet anti-rayonnement sur le boîtier du
ventilateur. Assurez-vous que l’ENCOCHE (D) est
bien positionnée par rapport à LOUVERTURE DU
RACCORD DU CONDUIT (E).
4. Alignez les supports du clapet anti-rayonnement avec
les orifices du boîtier du ventilateur. Fixez les supports
sur le boîtier du ventilateur avec (4) VIS À TÔLE À
TÊTE HEXAGONALE N°8 X 3/8PO (F) (fournies dans
le sac de pièces du clapet anti-rayonnement.)
Étapes 5 à 9:
Ventilateurs à éclairage, ventilateurs à capteur
d’humidité ou de mouvement SEULEMENT.
Pour les ventilateurs sans éclairage, capteur d’humidité ou
de mouvement: Passez à l’étape10.
5. Allongez les fils de connexion. Achetez l’ensemble
de cavaliers modèle RDJUMPU ou RDJUMPU1chez
votre détaillant ou distributeur local Broan.
Cet ensemble contient:
1 - Cavalier pour les modèles de ventilateur à éclairage
1 - Cavalier pour les modèles de ventilateur à capteur
6a. Pour les ventilateurs à éclairage incandescent ou
fluorescent, branchez une extrémité du CAVALIER
D’ÉCLAIRAGE (G) sur le connecteur correspondant
dans le boîtier de câblage du ventilateur.
6b. Pour les ventilateurs à éclairage DEL, branchez une
extrémité du CAVALIER D’ÉCLAIRAGE (G) sur le
connecteur correspondant venant de la COMMANDE
DE DEL (H).
6c. Pour les ventilateurs dotés de capteurs d’humidité ou de
mouvement, branchez une extrémité du CAVALIER DU
CAPTEUR (I) sur le connecteur correspondant dans le
boîtier de câblage du ventilateur.
7. Acheminez le(s) CAVALIER(S) (G) (I) vers
l’ENCOCHE (D) du cadre du clapet.
8. Pressez les fils de cavalier dans le TUBE D’ISOLATEUR
FENDU EN PLASTIQUE (J) (fourni dans le sac de pièces
du clapet). Poussez le tube fendu en plastique dans
l’ENCOCHE (D).
9. Alignez l’ergot du SERRE-CÂBLE (K) sur la fente
correspondante dans la rallonge du clapet. Fixez le
serre-câble avec les VIS À TÔLE N°8 x 3/8 PO (F)
fournies.
C
A
RDFU – Guide d’installation
Page 9
I *
G
B
C
F
D
E
F
K
J
VENTILATEURS À ÉCLAIRAGE
INCANDESCENT OU
FLUORESCENT
I * Cavalier pour unités à
capteur de mouvement ou
d’humiditéseulement.
I *
G
H
VENTILATEURS À
ÉCLAIRAGE À DEL
I * Cavalier pour unités à
capteur de mouvement ou
d’humidité seulement.
RDFU – Guide d’installation
Page 10
L
snap!
clic!
L
M
Étape 10:
Modèles RB, XB, ZB, RN, XN, ZN SEULEMENT
10. Faites glisser le CADRE DE MONTAGE (L) sur le
boîtier du ventilateur. Relevez le cadre autour du
boîtier jusqu’à ce qu’il s’emboîte en place.
Fixez le cadre de montage sur le boîtier du ventilateur
à l’aide de (2) VIS À TÔLE À TÊTE PLATE N°8
X 3/8PO (M) fournies dans le sac de pièces du
ventilateur.
Étape 11:
Modèles QT SEULEMENT
11. Fixez les PROFILÉS DE MONTAGE (N) sur le boîtier
à l’aide des VIS (O) fournies dans le sac de pièces
duventilateur.
Insérez les SUPPORTS À GLISSIÈRES (P) dans les
profilés de montage.
VIS DU SAC
DE PIÈCES
INSÉREZ
L’ERGOT DANS
LA FENTE DU
BOÎTIER
LES BRIDES INFÉRIEURE ET SUPÉRIEURE
RESTENT À L’EXTÉRIEUR DU BOÎTIER
12. Installez un RACCORD DE CONDUIT (Q) DE
15CM (6 PO) sur le boîtier du ventilateur et
fixez-le à l’aide des vis fournies dans le sac de
piècesdu ventilateur.
Q
N
O
P
RDFU – Guide d’installation
Page 11
Installer le ventilateur/clapet anti-rayonnement
15. Reportez-vous aux directives accompagnant le
ventilateur pour connaître les diverses configurations
de câblage électrique.
16. Installez le MASQUE DE BOÎTIER (R) fourni avec
le ventilateur pour protéger celui-ci et le clapet de
la poussière de construction, des pulvérisations sur
cloison sèches, etc.
Terminer l’installation du ventilateur
17. Finissez le plafond autour de l'ouverture du clapet anti-
rayonnement. L'ouverture pratiquée dans le plafond ne
doit pas être plus grande que le contour du clapet.
18. Retirez le MASQUE (R) du boîtier.
R
1
2
FIL DACIER
DE CALIBRE
12AU MINIMUM
(3MM)
(4)
1
2
BARRES DE
SUSPENSION
COULISSANTES
VIS À TÔLE N°8 (M4) OU
BOULONS DE ¼PO DE
DIAMÈTRE ET ÉCROUS
(4)
Installez le ventilateur/clapet anti-rayonnement au plafond
ASSUREZ-VOUS QUE LE DESSOUS DU CLAPET EST
AU RAS DE LA SURFACE FINIE DU PLAFOND.
13. Si l’ensemble de ventilateur est suspendu à la charpente
du plafond, DU FIL D'ACIER DE CALIBRE 12 (3 MM) AU
MINIMUM doit être utilisé pour le suspendre. Placez un fil
de chaque côté du ventilateur et fixez-les aux profilés de
montage tel qu’illustré.
14. Si le ventilateur est fixé directement à la charpente ad-
jacente du plafond, utilisez DES VIS À TÔLE N° 8 (M4)
OU DES BOULONS DE ¼ PO (6 MM) DE DIAMÈTRE
ET DES ÉCROUS pour fixer LES BARRES DE SUS-
PENSION COULISSANTES. Les barres de suspension
coulissantes fournies permettent de positionner avec pré-
cision le boîtier du ventilateur entre les solives du plafond.
RDFU – Guide d’installation
Page 12
Accès au ventilateur pour l'entretien
Si le ventilateur doit être entretenu ou réparé, la partie
intérieure du clapet peut être retirée du cadre extérieur sans
abîmer le matériau environnant du plafond.
Installer la grille
1
2
Étape 19:
Ventilateurs à éclairage SEULEMENT.
19. Raccordez le connecteur du CAVALIER D’ÉCLAIRAGE
(G) au(x) connecteur(s) correspondant(s) de la grille.
S
T
G
I
Enlevez la grille et débranchez toutes les connexions
électriques de la grille.
Enlevez les quatre (4) vis, puis abaissez le clapet intérieur
pour accéder au ventilateur. Replacez le clapet avant de faire
fonctionner le ventilateur.
Étape 20:
Ventilateurs à capteur d’humidité et de
mouvementSEULEMENT.
20. Raccordez le FIL DE CAVALIER DU CAPTEUR (I)
dans le connecteur du capteur situé sur la grille.
21. Pincez les 2 RESSORTS DE LA GRILLE (S) et insérez-les
dans les encoches du cadre du clapet anti-rayonnement.
Repoussez la GRILLE (T) fermement contre la surface
duplafond.
Si un jeu supplémentaire est nécessaire entre le plafond
et la grille, remplacez les ressorts de la grille par des
ressorts plus longs (fournis dans le sac de pièces).
99045951B
Limited Warranty
Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its
workmanship for a period of one (1) year from the date of original purchase.
The limited warranty period for any replacement parts provided by the Company and for any Products repaired or replaced under this limited warranty shall be the remainder of the original warranty period.
This warranty does not cover speed controls, fluorescent lamp starters, tubes, halogen and incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and other accessories for ducting that may be purchased separately and
installed with the Product. This warranty also does not cover (a)normal maintenance and service, (b)normal wear and tear, (c)any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident,
improper or insufficient maintenance, storage or repair (other than repair by the Company), (d)damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (e)any Product that has been
moved from its original point of installation, (f)damage caused by environmental or natural elements, (g)damage in transit, (h)natural wear of finish, (i)Products in commercial or nonresidential use, or (j)damage caused by fire,
flood or other act of God. This warranty covers only Products sold to original consumers in the United States by the Company or U.S. distributors authorized by the Company.
This warranty supersedes all prior warranties and is not transferable from the original consumer purchaser.
No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your sole remedy for defective products. The foregoing warranties are exclusive and in lieu of any other warranties, express or implied. THE
COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. To the extent that applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the period specified for the express warranty
above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it and shall not be
construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law, but if any provision is held to be prohibited or invalid, such provision shall be ineffective
only to the extent of such prohibition or invalidity, without invalidating the remainder of such provision or the other remaining provisions of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without charge, any Product or part thereof, to the extent the Company finds it to be covered
by and in breach of this limited warranty under normal use and service. The Company will ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all costs for removal, reinstallation and
shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send the Product or part to the Company, as instructed by the Company, you must properly pack the Product
or part—the Company is not responsible for damage in transit. The Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the warranty repair or replacement process. Such
Products and parts will be comparable in function and performance to an original Product or part and warranted for the remainder of the original warranty period.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT THE COMPANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED
WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
THE PRODUCT, ITS USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights,
which vary from state to state.
This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main facility and does not include the cost of field service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute a waiver of such terms, limitations or exclusions, nor will such assistance extend
or revive the warranty.
The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective Product, except for those incurred with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a)notify the Company at the address or telephone number stated below within seven (7)days of discovering the covered defect, (b)give the model number
and part identification and (c)describe the nature of any defect in the Product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot provide a copy of the original
written limited warranty, then the terms of the Company’s most current written limited warranty for your particular product will control.The most current limited written warranties for the Company’s products can be found at www.
broan.com .
Broan 926 West State Street Hartford, WI 53027 www.broan.com 800-637-1453
RDFU
Regulador de radiación
deprimera calidad
GUÍA DE INSTALACIÓN
LEA Y CONSERVE ESTAS INSTRUCCIONES
Instalador: Deje esta guía con el dueño de la casa.
Registre su producto en línea en: www.broan.com/register o www.nutone.com/register.
Instalación sencilla
© 2017 Broan
Guía de instalación del RDFU
Página 14
Para usarse en los diseños de piso a cielo raso y techo a cielo raso con clasificación de 1, 2 o 3 horas.
Solo montaje horizontal / en cielo raso plano.
Para usarse con los siguientes modelos de ventilador:
Broan QT130E, QT130LE, QT140E, QT140LE, QTXE150, QTXE150FLT, RB80, RB80L, RB80L1, RB110,
RB110L, RB110L1, XB50, XB80, XB110, XB50L, XB50L1, XB80L, XB80L1, XB110L, XB110L1, XB110H,
XB110HL, XB110HL1, ZB80, ZB110, ZB80L, ZB80L1, ZB110L, ZB110L1, ZB110H, ZB110HL, ZB110HL1,
ZB80M, ZB110M, ZB80ML, ZB80ML1, ZB110ML, ZB110ML1
NuTone QTN130E, QTN130LE1, QTXEN150, QTXEN150FLT, RN80, RN80L, RN110, RN110L, XN50, XN80,
XN110, XN50L, XN80L, XN110L, XN110H, XN110HL, ZN80, ZN110, ZN80L, ZN110L, ZN110H, ZN110HL,
ZN80M, ZN110M, ZN80ML, ZN110ML
Twin City T080E, T110E, T150LP
Uso
VEA LOS DETALLES
EN LA MARCA DE
CLASIFICACIÓN UL DEL
PRODUCTO
Preparación del ventilador
Los siguientes pasos se realizan mejor sobre una superficie
de trabajo antes de instalar el ventilador. Proteja las cubiertas
colocando una hoja corrugada debajo del ventilador.
1. Instale dos (2) TORNILLOS DE CHAPA METÁLICA DE
CABEZA HEXAGONAL #8 x ½pulg. (A) que se suministran
en la bolsa de piezas del ventilador.
2. Deslice cuatro (4) SOPORTES DE MONTAJE (B) en las
ranuras en cuatro lados del MARCO DE EXTENSIÓN DEL
REGULADOR DE RADIACIÓN (C). Después del montaje,
asegúrese de que encajen a presión en su lugar y se
enganchen de forma segura.
3. Centre el regulador de radiación sobre la cubierta del
ventilador. Asegúrese de que la MUESCA (D) esté colocada
correctamente en relación con la ABERTURA DEL
CONECTOR DE CONDUCTO (E).
4. Alinee los soportes del regulador de radiación con los orificios
en la cubierta del ventilador. Fije los soportes a la cubierta del
ventilador con cuatro (4) TORNILLOS DE CHAPA METÁLICA
#8 X 3/8 PULG. (F) (que se suministran en la bolsa de piezas
del regulador de radiación).
Pasos 5 a 9:
SOLAMENTE ventiladores con luz, ventiladores con sensor
de humedad y ventiladores con sensor demovimiento.
Para ventiladores que no estén equipados con luz, sensor de
humedad o sensor de movimiento: Diríjase al paso10.
5. Alargue los cables principales. Adquiera el juego de puentes
modelo RDJUMPU o RDJUMPU1 con su distribuidor o
concesionario local autorizado de Broan.
Cada juego contiene:
1 - puente para los modelos de ventilador con luz
1 - puente para los modelos de ventilador con sensor
6a. Para ventiladores equipados con luces incandescentes
o fluorescentes, conecte un extremo del PUENTE DE
ILUMINACIÓN (G) al conector correspondiente en la caja
de cableado del ventilador.
6b. Para ventiladores equipados con luces LED, conecte un
extremo del PUENTE DE ILUMINACIÓN (G) al conector
correspondiente del CONTROLADOR DE LED (H).
6c. Para ventiladores equipados con sensores de humedad
o de movimiento, conecte un extremo del PUENTE DEL
SENSOR (i) al conector correspondiente en la caja de
cableado del ventilador.
7. Pase los PUENTES (G) (I) hacia la MUESCA (D) del marco
del regulador.
8. Presione los cables puente en el AISLANTE DE TUBO
DIVIDIDO DE PLÁSTICO (J) (suministrado en la bolsa de
piezas del regulador). Empuje el tubo dividido de plástico
dentro de la abertura de la MUESCA (D).
9. Alinee la lengüeta de la ABRAZADERA DEL CABLE (K)
con la ranura correspondiente en la extensión del regulador.
Fije la abrazadera con el TORNILLO DE CHAPA METÁLICA
#8 x 3/8 pulg. (F) suministrado.
C
A
Guía de instalación del RDFU
Página 15
I *
G
B
C
F
D
E
F
K
J
VENTILADORES CON
LUCES INCANDESCENTES
OFLUORESCENTES
I * Puente solo para unidades
con sensor de movimiento o
dehumedad.
I *
G
H
VENTILADORES CON
LUCESLED
I * Puente solo para unidades
con sensor de movimiento o
dehumedad.
Guía de instalación del RDFU
Página 16
L
cilc!
L
M
Paso 10:
SOLAMENTE modelos RB, XB, ZB, RN, XN, ZN
10. Deslice el MARCO DE MONTAJE (L) en la cubierta del
ventilador. Suba el marco alrededor de la cubierta hasta
quequede sujetado a presión.
Fije el marco de montaje a la cubierta del ventilador con
dos (2) TORNILLOS DE CHAPA METÁLICA DE CABEZA
PLANA #8 X 3/8 pulg. (M) que se suministran en la bolsa
de piezas del ventilador.
Paso 11:
SOLAMENTE modelos QT
11. Sujete los CANALES DE MONTAJE (N) a la cubierta con
los TORNILLOS (O) que se suministran en la bolsa de
piezas del ventilador.
Introduzca los SOPORTES DESLIZANTES (P) en los
canales de montaje.
N
O
P
TORNILLODE
LA BOLSA
DEPIEZAS
INTRODUZCALA
PESTAÑA EN
LA RANURA DE
LACUBIERTA
LAS BRIDAS SUPERIOR E INFERIOR
PERMANECEN FUERA DE LA CUBIERTA
12. Instale el CONECTOR DE CONDUCTO DE 6 pulg. (Q) en
la cubierta del ventilador y asegúrelo con el tornillo incluido
en la bolsa de piezas del ventilador.
Q
Guía de instalación del RDFU
Página 17
Instale el ventilador/regulador de radiación
15. Consulte las instrucciones suministradas con el ventilador
para ver las diferentes configuraciones de cableado eléctrico.
16. Instale la COBERTURA (R) suministrada con el ventilador a
fin de proteger el regulador y el ventilador contra los rociados
de yeso, polvos de construcción, etc.
Termine la instalación
17. Termine el cielo raso alrededor de la abertura del regulador.
La abertura del cielo raso no debe ser más grande que el
exterior del regulador de radiación.
18. Retire la
COBERTURA (R)
de la cubierta.
RO
1
2
ALAMBRE DE
ACERO CON
UN CALIBRE 12
(3 MM) COMO
MÍNIMO
(4)
1
2
BARRAS DE
SUSPENSIÓN
DESLIZANTES
TORNILLOS DE CHAPA
METÁLICA #8 (M4) O
PERNOS DE ¼ PULG.
DEDIÁMETRO CON
TUERCAS
(4)
Instale el ventilador/regulador de radiación en el cielo raso
ASEGÚRESE DE QUE EL CIELO RASO TERMINADO ESTÉ AL RAS
CON EL BORDE INFERIOR DEL REGULADOR DE RADIACIÓN.
13. Si el conjunto del ventilador se va a colgar de la estructura
superior, SE DEBE USAR UN ALAMBRE DE ACERO
CON UN CALIBRE 12 (3 MM) como mínimo para colgar el
ventilador. Use un alambre a cada lado del ventilador para
fijarlo a los canales de montaje como se muestra.
14. Si el ventilador se monta directamente a la estructura de cielo
raso adyacente, use TORNILLOS DE CHAPA METÁLICA #8
(M4) O PERNOS DE ¼ PULG. (6 MM) DE DIÁMETRO CON
TUERCAS para sujetar LAS BARRAS DE SUSPENSIÓN
DESLIZANTES. Se proporcionan barras de suspensión
deslizantes para facilitar la colocación precisa del ventilador
entre las piezas estructurales del cielo raso.
Guía de instalación del RDFU
Página 18
Función de servicio para ventiladores
Si su ventilador necesita servicio de reparación/mantenimiento, es
posible quitar el regulador interior del marco exterior sin perturbar
el material del cielo raso circundante.
Instale la rejilla
1
2
Paso 19:
SOLAMENTE ventiladores con luz.
19. Fije el conector del CABLE PUENTE DE LA LUZ (G) a los
conectores correspondientes de la rejilla.
S
T
G
I
Quite la rejilla y desconecte todas sus conexiones eléctricas.
Quite los cuatro (4) tornillos y luego baje el regulador interior para
tener acceso al ventilador. Reinstale el regulador interior antes de
activar el ventilador.
Paso 20:
SOLAMENTE ventiladores con sensor de humedad y
ventiladores con sensor de movimiento
20. Conecte EL CABLE DE PUENTE DEL SENSOR (I) en el
conector del sensor ubicado en la rejilla.
21. Comprima 2 RESORTES DE LA REJILLA (S) y deslícelos
dentro de las lengüetas del marco del regulador de radiación.
Empuje la REJILLA (T) hasta que esté firme contra la
superficie del cielo raso.
Si es necesaria una mayor separación entre el cielo raso y la
rejilla, reemplace los resortes de la rejilla por unos más largos
(suministrados en la bolsa de piezas).
99045951B
Limited Warranty
Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its
workmanship for a period of one (1) year from the date of original purchase.
The limited warranty period for any replacement parts provided by the Company and for any Products repaired or replaced under this limited warranty shall be the remainder of the original warranty period.
This warranty does not cover speed controls, fluorescent lamp starters, tubes, halogen and incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and other accessories for ducting that may be purchased separately and
installed with the Product. This warranty also does not cover (a)normal maintenance and service, (b)normal wear and tear, (c)any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident,
improper or insufficient maintenance, storage or repair (other than repair by the Company), (d)damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (e)any Product that has been
moved from its original point of installation, (f)damage caused by environmental or natural elements, (g)damage in transit, (h)natural wear of finish, (i)Products in commercial or nonresidential use, or (j)damage caused by fire,
flood or other act of God. This warranty covers only Products sold to original consumers in the United States by the Company or U.S. distributors authorized by the Company.
This warranty supersedes all prior warranties and is not transferable from the original consumer purchaser.
No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your sole remedy for defective products. The foregoing warranties are exclusive and in lieu of any other warranties, express or implied. THE
COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. To the extent that applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the period specified for the express warranty
above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it and shall not be
construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law, but if any provision is held to be prohibited or invalid, such provision shall be ineffective
only to the extent of such prohibition or invalidity, without invalidating the remainder of such provision or the other remaining provisions of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without charge, any Product or part thereof, to the extent the Company finds it to be covered
by and in breach of this limited warranty under normal use and service. The Company will ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all costs for removal, reinstallation and
shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send the Product or part to the Company, as instructed by the Company, you must properly pack the Product
or part—the Company is not responsible for damage in transit. The Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the warranty repair or replacement process. Such
Products and parts will be comparable in function and performance to an original Product or part and warranted for the remainder of the original warranty period.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT THE COMPANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED
WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
THE PRODUCT, ITS USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights,
which vary from state to state.
This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main facility and does not include the cost of field service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute a waiver of such terms, limitations or exclusions, nor will such assistance extend
or revive the warranty.
The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective Product, except for those incurred with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a)notify the Company at the address or telephone number stated below within seven (7)days of discovering the covered defect, (b)give the model number
and part identification and (c)describe the nature of any defect in the Product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot provide a copy of the original
written limited warranty, then the terms of the Company’s most current written limited warranty for your particular product will control.The most current limited written warranties for the Company’s products can be found at www.
broan.com .
Broan 926 West State Street Hartford, WI 53027 www.broan.com 800-637-1453
RDFU – Installation Guide / Guide
d’installation / Guía de instalación
Page / Página 19
RDFU – Installation Guide / Guide
d’installation / Guía de instalación
Page / Página 20
99045951B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Broan RDFU Guía de instalación

Categoría
Ventiladores domésticos
Tipo
Guía de instalación
Este manual también es adecuado para

En otros idiomas