Wiremold 30TC-3S2 Guía de instalación

Tipo
Guía de instalación
Wiremold
®
Tele-Power
®
Poles
Poteaux Tele-Power
®
Barras Tele-Power
®
30TC-4V, 30TP-4V
Country of Origin: Made in USA • Fabriqué en USA • Hecho en USA

Please read all instructions before
beginning installation
Legrand electrical systems conform to and
should be properly grounded in compliance with
requirements of the current National Electrical
Code or codes administered by local authorities.
All electrical products may present a possible
shock or re hazard if improperly installed or used.
Legrand electrical products may bear the mark of
a Nationally Recognized Testing Laboratory and
should be installed in conformance with current
local and/or the National Electrical Code.

VEUILLEZ LIRE L'ENSEMBLE
DES INSTRUCTIONS AVANT DE
COMMENCER L'INSTALLATION.
Les systèmes électriques Legrand sont
conformes au Code National de l'électricité
(National Electrical Code) ou aux codes
locaux en vigueur et doivent être mis à la terre
conformément à ces codes.
Tous les produits électriques peuvent présenter
un risque d'électrocution ou d'incendie s'ils ne
sont pas installés ou utilisés correctement. Les
produits électriques Legrand peuvent porter la
marque d'un laboratoire reconnu et doivent être
installés conformément au Code national de
l'électricité et/ou aux codes locaux en vigueur.

Lea todas las instrucciones antes
de comenzar la instalación.
Los sistemas eléctricos Legrand cumplen con los
requisitos del Código Eléctrico Nacional (National
Electrical Code, NEC) actual o con los códigos
impuestos por las autoridades locales y deben
conectarse a tierra consecuentemente.
Todos los productos eléctricos pueden presentar
un riesgo de descarga o incendio si se los instala o
utiliza incorrectamente. Los productos eléctricos
Legrand pueden llevar la marca de un laboratorio
de pruebas reconocido a nivel nacional y se deben
instalar conforme al código local en vigencia o al
Código Eléctrico Nacional.
No: 1011594 – 06/14 Installation Instructions • Notice d’Installation• Instrucciones de Instalación
30TC-4V*, 30TP-4V
3" [76.2mm]
3 po [76,2mm]
3" [76,2 mm]
2 3/4" [69.85mm]
2 3/4 po [69,85mm]
2 3/4" [69,85 mm]
1 1/2"
[38.1mm]
1 1/2 po
[38,1 mm]
1 1/2"
[38,1 mm]
30TP-4V3S2
30TP-412V3S2
30TP-4V
30TC-3S2
(with adapter installed)

(con el adaptador instalado)
30TC-CVR
30TP-C
30TP-J
(1.59 [40.39mm] diameter)
(diamètre de 40,39 mm
[1,59 po])
(1,59 [40,39 mm] de

30TP-A
(1.40 [35.56mm]
diameter)
(diamètre de 35,56
mm [1,40 po])
(1,40 [35,56 mm] de

30TP-B
30TC-4V*
30TP-L
* 30TC-4V Series not intended for combining power and communications in the same channel.

le même conduit.

en el mismo canal.
3
1

2a 2b
3 4 5
Tipo de cable
Descripción cant.



(pulgadas) [mm]
PASO PASO
COND. 40 % COND. 40 %
Serie AMDTP Serie 25DTP

 Comp. grande
PASO
COND. 40 %
PASO
COND. 40 %
PASO
COND. 40 %
PASO
COND. 40 %
THHN / THWN 10 Awg
0.16 4.17
10 10 34 44
12 Awg
0.13 3.30 15 15 54 69
CAPACIDADES DE PASO DE CONDUCTORES EN CONDUCTOS ELÉCTRICOS PARA BARRAS TELE POWER –

CUADROS DE CAPACIDAD DE PASO DE CONDUCTORES

Tipo de cable
-


(pulgadas) [mm]
Serie AMDTP
PASO
PASO
COND.
COND.
20 %
40 %
Serie 25DTP
PASO
PASO
COND.
COND.
20 %
40 %

PASO
PASO
COND.
COND.
20 %
40 %
Comp. grande
PASO
PASO
COND.
COND.
20 %
40 %
Par trenzado
sin blindaje
Cat. 5 UTP
0.22 5.59 10 19 10 19 10 19 13 26
Cat. 3 UTP
0.19 4.83 13 25 13 25 13 25 17 35
Teléfono
2 Pares
0.14 3.56 23 47 23 47 23 47 32 64
3 Pares
0.15 3.81 20 41 20 41 20 41 28 56
4 Pares
0.19 4.83 13 25 13 25 13 25 17 35
25 Pares
0.41 10.41 3 5 3 5 3 5 4 7
RG58/U
0.20 4.95 12 24 12 24 12 24 17 33
Coaxial
RG59/U
0.24 6.15 8 16 8 16 8 16 11 21
RG62/U
0.24 6.15 8 16 8 16 8 16 11 21
RG6/U
0.27 6.86 6 13 6 13 6 13 9 17
Axial retorcido
100 ohmios
0.33 8.38 4 8 4 8 4 8 6 12
Par trenzado
con blindaje
Tipo 1 STP
0.39 9.91 3 6 3 6 3 6 4 8
Tipo 2 STP
0.47 11.81 2 4 2 4 2 4 3 6
Tipo 3 STP
0.25 6.22 8 15 8 15 8 15 10 21
Fibra óptica
ZipCord de fibra óptica
0.11 2.79 38 76 38 76 38 76 52 104
Fibra óptica, 2 hilos, sección circular
0.18 4.57 14 28 14 28 14 28 19 39
Fibra óptica, 4 hilos, sección circular
0.19 4.83 13 25 13 25 13 25 17 35
Fibra óptica, 6 hilos, sección circular
0.21 5.33 10 21 10 21 10 21 14 29

CAPACIDADES DE PASO DE CONDUCTORES EN CONDUCTOS ELÉCTRICOS PARA BARRAS TELE POWER – COMUNICACIONES
 
 
 

Transcripción de documentos

Wiremold® Tele-Power® Poles Poteaux Tele-Power® Barras Tele-Power® No: 1011594 – 06/14 Installation Instructions • Notice d’Installation• Instrucciones de Instalación Catalog Number(s) • Numéro(s) de Catalogue • Número(s) de Catálogo: 30TC-4V, 30TP-4V Country of Origin: Made in USA • Fabriqué en USA • Hecho en USA Important: Please read all instructions before beginning installation Legrand electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical products may present a possible shock or fire hazard if improperly installed or used. Legrand electrical products may bear the mark of a Nationally Recognized Testing Laboratory and should be installed in conformance with current local and/or the National Electrical Code. Important : Veuillez lire l'ensemble des instructions avant de commencer l'installation. Les systèmes électriques Legrand sont conformes au Code National de l'électricité (National Electrical Code) ou aux codes locaux en vigueur et doivent être mis à la terre conformément à ces codes. Tous les produits électriques peuvent présenter un risque d'électrocution ou d'incendie s'ils ne sont pas installés ou utilisés correctement. Les produits électriques Legrand peuvent porter la marque d'un laboratoire reconnu et doivent être installés conformément au Code national de l'électricité et/ou aux codes locaux en vigueur. IMPORTANTE: Lea todas las instrucciones antes de comenzar la instalación. Los sistemas eléctricos Legrand cumplen con los requisitos del Código Eléctrico Nacional (National Electrical Code, NEC) actual o con los códigos impuestos por las autoridades locales y deben conectarse a tierra consecuentemente. Todos los productos eléctricos pueden presentar un riesgo de descarga o incendio si se los instala o utiliza incorrectamente. Los productos eléctricos Legrand pueden llevar la marca de un laboratorio de pruebas reconocido a nivel nacional y se deben instalar conforme al código local en vigencia o al Código Eléctrico Nacional. 30TC-4V*, 30TP-4V 1 1/2" [38.1mm] 1 1/2 po [38,1 mm] 3" [76.2mm] 3 po [76,2mm] 1 1/2" [38,1 mm] 3" [76,2 mm] 30TC-3S2 (with adapter installed) 2 3/4" [69.85mm] 2 3/4 po [69,85mm] 2 3/4" [69,85 mm] 30TP-4V3S2 30TP-412V3S2 30TP-4V 30TC-CVR 30TP-C (avec adaptateur installé) (con el adaptador instalado) 30TC-4V* * 30TC-4V Series not intended for combining power and communications in the same channel. * Avec la série 30TC-4V, il n'est pas prévu d'associer l'alimentation et la communication dans le même conduit. * La Serie 30TC-4V no está diseñada para combinar alimentación electrica y comunicaciones en el mismo canal. 30TP-L 30TP-J (1.59 [40.39mm] diameter) (diamètre de 40,39 mm [1,59 po]) (1,59 [40,39 mm] de diámetro) 30TP-A (1.40 [35.56mm] diameter) (diamètre de 35,56 mm [1,40 po]) (1,40 [35,56 mm] de diámetro) 30TP-B Cuadros de capacidad de paso de conductores Capacidades de paso de conductores en conductos eléctricos para barras Tele Power – ALIMENTACIÓN ELÉCTRICA Series AMTC y 25DTC* Diámetro exterior Descripción cant. Serie AMDTP Serie 25DTP [mm] Comp. pequeño Comp. grande conductores y (pulgadas) PASO tamaño del cable PASO PASO PASO PASO PASO COND. 40 % COND. 40 % COND. 40 % COND. 40 % COND. 40 % COND. 40 % THHN / THWN 10 Awg 10 10 34 44 0.16 4.17 Tipo de cable 12 Awg 0.13 3.30 15 15 54 69 Capacidades de paso de conductores en conductos eléctricos para barras Tele Power – COMUNICACIONES Series AMTC y 25DTC* Descripción cant. conductores y tamaTipo de cable ño del cable Par trenzado sin blindaje Teléfono Coaxial Axial retorcido Par trenzado con blindaje Fibra óptica Serie 25DTP Comp. pequeño Comp. grande Serie AMDTP PASO PASO PASO PASO PASO PASO PASO PASO COND. COND. COND. COND. COND. COND. COND. COND. 40 % 20 % 40 % 20 % 40 % 20 % 40 % (pulgadas) [mm] 20 % Diámetro interior Cat. 5 UTP 0.22 5.59 10 19 10 19 10 19 13 26 Cat. 3 UTP 0.19 4.83 13 25 13 25 13 25 17 35 2 Pares 0.14 3.56 23 47 23 47 23 47 32 64 3 Pares 4 Pares 25 Pares RG58/U RG59/U RG62/U RG6/U 100 ohmios Tipo 1 STP Tipo 2 STP Tipo 3 STP ZipCord de fibra óptica Fibra óptica, 2 hilos, sección circular 0.15 0.19 0.41 0.20 0.24 0.24 0.27 0.33 0.39 0.47 0.25 0.11 0.18 3.81 4.83 10.41 4.95 6.15 6.15 6.86 8.38 9.91 11.81 6.22 2.79 4.57 20 13 3 12 8 8 6 4 3 2 8 38 14 41 25 5 24 16 16 13 8 6 4 15 76 28 20 13 3 12 8 8 6 4 3 2 8 38 14 41 25 5 24 16 16 13 8 6 4 15 76 28 20 13 3 12 8 8 6 4 3 2 8 38 14 41 25 5 24 16 16 13 8 6 4 15 76 28 28 17 4 17 11 11 9 6 4 3 10 52 19 56 35 7 33 21 21 17 12 8 6 21 104 39 Fibra óptica, 4 hilos, sección circular 0.19 4.83 13 25 13 25 13 25 17 35 Fibra óptica, 6 hilos, sección circular 0.21 5.33 10 21 10 21 10 21 14 29 * Las Series 25DTC/AMTC no están diseñadas para combinar alimentación eléctrica y comunicaciones en el mismo canal. Installation: • Installation : • Instalación: 1 2a 2b 3 4 5 NOTE: With recommended #10 pan head screw. REMARQUE : il est recommandé d'utilisé une vis à tête cylindrique n° 10. NOTA: Con tornillo de cabeza troncocónica #10 recomendado. 3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Wiremold 30TC-3S2 Guía de instalación

Tipo
Guía de instalación