CARLO GAVAZZI RVPM3400800FPF El manual del propietario

Tipo
El manual del propietario

Este manual también es adecuado para

RVPM series
1-phase and 3-phase compressor drive
УПП общепромышленного применения
通用软启动器
INST_RVPM (09072021)
ATTENTION
1. To prevent electrical shock, disconnect from power source
before installing or servicing.
2. “For use in Pollution Degree 2 Environment”.
3. The device should be configured as indicated in the
connection diagram. Do not operate the product before all
connections are completed.
4. The RVPM does not have any integrated short circuit and
overload protection. These must be procured separately.
5. Excessive lengths of cabling should be avoided in view of
EMC considerations.
6. Use shielded cables. The cable shield must be connected
to ground. Separate as much as possible the probe and digital
input signal cables from the cables carrying inductive loads
and power cables to avoid possible electromagnetic distur-
bance. Never run power cables (including the electrical panel
wiring) and signal cables in the same conduits
WEEE designation
Do not dispose of the product together with the house-
hold waste but according to the disposal regulations for
electronic waste locally applicable at the product installation
site.
BEMÆRK
1. For at undgå elektrisk stød skal du afbryde strømkilden
inden installation eller service.
2. “Til anvendelse i miljøer med forureningsgrad 2”.
3. Enheden skal konfigureres som angivet i tilslutningsdia-
grammet. Brug ikke produktet, før alle tilslutninger er fuldført.
4. RVPM har ingen integreret kortslutnings- og overbelast-
ningsbeskyttelse. De skal anskaffes separat.
5. For lange kabler skal undgås i betragtning af EMC-
overvejelser.
6. Brug afskærmede kabler. Kabelskærmen skal jordforbind-
es. Adskil så meget som muligt sonden og de digitale
indgangssignalkabler fra de kabler, der bærer induktive
belastninger, og strømkabler for at undgå mulig elektro-
magnetisk forstyrrelse. Brug aldrig strømkabler inklusive
ledningsføringen til det elektriske panel og signalkabler i
samme rørledninger.
WEEE-betegnelse
Bortskaf ikke produktet sammen med husholdning-
saffald, men i henhold til bestemmelserne for bortskaffelse
af elektronisk affald, der er gældende på produktinstalla-
tionsstedet.
ATENCIÓN
1. Para evitar descargas eléctricas, desconecte la fuente de
alimentación antes de proceder con la instalación o el man-
tenimiento del producto.
2. «Para uso en ambiente de contaminación grado 2».
3. El dispositivo debe configurarse como se indica en el dia-
grama de conexión. No utilice el producto antes de completar
todas las conexiones.
4. El RVPM no dispone de ninguna protección integrada
contra cortocircuito ni sobrecarga. Estas se deben adquirir
por separado.
5. Se deben evitar longitudes excesivas del cableado con-
forme a las consideraciones sobre CEM.
6. Utilice cables apantallados. La pantalla del cable debe estar
conectada a tierra. Separe lo máximo posible la sonda y los
cables de la señal de entrada digital respecto a los cables de
las cargas inductivas y los cables de alimentación para evitar
posibles interferencias electromagnéticas. Nunca utilice los
mismos conductos para distribuir los cables de alimentación
(incluyendo el cableado del panel eléctrico) y los cables de
señal.
Designación WEEE
No se deshaga del producto junto con la basura domésti-
ca, sino de acuerdo con las disposiciones sobre eliminación
de residuos electrónicos aplicables a nivel local en el lugar de
instalación del producto.
ACHTUNG
1. Zur Vermeidung von elektrischen Stromschlägen trennen
Sie das Gerät vor der Installation oder Wartung von der
Stromquelle.
2. “Für den Einsatz in Umgebungen mit Verschmutzungsgrad 2”.
3. Das Gerät ist wie im Anschlussplan angegeben zu kon-
figurieren. Nehmen Sie das Gerät nicht in Betrieb, bevor alle
Anschlüsse hergestellt sind.
4. Der RVPM verfügt nicht über einen integrierten Kurzschluss-
und Überlastschutz. Diese sind separat zu beschaffen.
5. Übermäßige Längen der Verkabelung sind im Hinblick auf
EMV-Überlegungen zu vermeiden.
6. Verwenden Sie geschirmte Kabel. Der Kabelschirm muss
mit der Erdung verbunden sein. Verlegen Sie die Sonden-
und digitalen Eingangssignalkabel so weit wie möglich
von Kabeln, die induktive Lasten tragen, und Stromkabeln
entfernt, um mögliche elektromagnetische Störungen zu
vermeiden. Verlegen Sie Stromkabel (einschließlich der
Verdrahtung der Schalttafel) und Signalkabel niemals in
denselben Rohren
WEEE-Kennzeichnung
Entsorgen Sie das Produkt nicht zusammen mit
dem Hausmüll, sondern gemäß den am Installationsort
des Produkts geltenden Entsorgungsvorschriften für
Elektronikschrott.
!
!
!
ATTENTION
1. Pour éviter tout choc électrique, débrancher de la source
d’alimentation avant d’installer ou de réparer.
2. “À utiliser dans un environnement de degré de pollution 2”.
3. L’appareil doit être configuré comme indiqué dans le sché-
ma de connexion. Ne pas utiliser le produit avant que toutes
les connexions ne soient terminées.
4. Le RVPM n’a pas de protection intégrée contre les
courts-circuits et les surcharges. Ils doivent être acquis
séparément
5. Les longueurs de câblage excessives doivent être évitées
compte tenu des considérations EMC.
6. Utiliser des câbles blindés. Le blindage du câble doit être
connecté à la terre. Séparer le plus possible les câbles de
sonde et d’entrée numérique des câbles qui pourraient porter
des charges inductives et câbles d’alimentation pour éviter
la perturbation électromagnétique. Ne jamais faire passer
les câbles d’alimentation, y compris le câblage du panneau
électrique) et les câbles de signal dans les mêmes conduits
Désignation DAEE (Déchets des Appareils Électriques
et Électroniques)
Ne pas jeter le produit avec les ordures ménagères, mais
conformément aux réglementations d’élimination des déchets
électroniques applicables localement sur le site d’installation
du produit.
ATTENZIONE
1. Per evitare scosse elettriche, scollegarsi dalla fonte di
alimentazione prima di procedere all’installazione o alla
manutenzione.
2. “Da utilizzare in ambiente con grado 2 di inquinamento”.
3. Il dispositivo deve essere configurato come indicato nello
schema di connessione. Non mettere in funzione il prodotto
prima che tutte le connessioni siano completate.
4. Il RVPM non dispone di un cortocircuito integrato e di
protezione contro il sovraccarico. Devono essere acquistati
separatamente.
5. Date le considerazioni EMC, è consigliabile evitare cab-
laggi troppo lunghi.
6. Utilizzare cavi schermati. La schermatura del cavo deve
essere collegato alla terra. Separare il più possibile i cavi
della sonda e di input digitale dai cavi che potrebbero cau-
sare carichi induttivi e cavi di alimentazione per evitare pos-
sibili interferenze elettromagnetiche. Non azionare mai cavi
di alimentazione (compresi i cablaggi del quadro elettrico) e
cavi di segnale negli stessi condotti designazione
RAEE (Rifiuti da Apparecchiature Elettriche ed
Elettroniche)
Non smaltire il prodotto insieme a rifiuti domestici, ma sec-
ondo le norme di smaltimento di rifiuti elettronici localmente
applicabili nel sito di installazione del prodotto.
ВНИМАНИЕ
1. Во избежание поражения электрическим током, перед
установкой или обслуживанием отключите от источника
питания.
2. «Для применения в среде со степенью загрязнения 2».
3. Устройство должно быть сконфигурировано, как указано
на схеме соединений. Запрещено эксплуатировать данное
изделие, пока не будут выполнены все подсоединения.
4. Устройство RVPM не имеет встроенной защиты от
короткого замыкания и перегрузки. Их необходимо
обеспечить отдельно.
5. Следует избегать слишком длинного кабеля по причине
ЭМС.
6. Используйте экранированные кабели. Оболочка кабеля
должна быть заземлена. Обеспечьте как можно большее
расстояние от кабелей цифрового входного сигнала и
датчика до кабелей с индуктивными нагрузками
и силовых кабелей во избежание возможных
электромагнитных помех. Запрещено прокладывать
силовые кабели (включая проводку электрощита) и кабели
передачи сигналов в одних и тех же кабель-каналах.
Положения об электронных отходах
Запрещено удалять данное изделие вместе с
бытовыми отходами, соблюдайте местные нормы и
правила удаления электронных отходов, которые действуют
на месте установки изделия.
注意事项
1.为了避免电击,在安装或维护时必须断开电源。
2.“适用于污染2级环境”。
3.按照连接布局图所示对装置进行配置。完成各项连
接之前,切勿操纵产品。
4.RVPM并未集成短路电路和过载保护装置。必须额
外购买这类装置。
5.鉴于电磁兼容性要求,应避免布线距离过长。
6.请使用带屏蔽层的电缆。屏蔽层必须接地。尽可能
将探针和数字输入信号电缆远离感性负载电缆和
供电电缆,避免电磁干扰。切勿将供电电缆(包括配
电板接线)与信号电缆置于同一
WEEE规格管道内。
切勿将产品与其他家庭废物一同丢弃,必须根据
产品安装所在地施行的电子废物处理规范进行处置。
!
!
!
Operating Instructions
Kom godt i gang
Instrucciones
Betriebsanleitung
Notice d’utilisation
Istruzioni d’uso
Руководство по эксплуатации
操作说明
IMPORTANT
Carlo Gavazzi is not to be held responsible for incorrect product operation
or damages resulting from improper use of the product and/or use of the
product outside its specified operating limits. Products, specifications
and data in this document are subject to change without notice. The
product is intended to be used by qualified personnel at their own discre-
tion and risk. Should you require information about installation, operation
or maintenance of the product that is not covered in this document you
should refer the matter to an authorized Carlo Gavazzi representative. The
information in this document is not considered binding on any product
warranty.
VIGTIGT
Carlo Gavazzi kan ikke holdes ansvarlig for ukorrekt anvendelse af
produktet eller skader opstået ved ukorrekt brug og/eller efter brug af
produktet til andet end de specificerede driftsbestemmelser. Produkter,
specifikationer og data i dette dokument kan ændres uden varsel.
Produktet er beregnet til anvendelse af uddannet personale efter eget
skøn og risiko. Hvis du har brug for oplysninger om installation, drift eller
vedligeholdelse af produktet, der ikke er dækket af nærværende doku-
ment, bør du rette henvendelse til en autoriseret repræsentant fra Carlo
Gavazzi. Informationen i nærværende dokument anses ikke for bindende
for nogen produktgaranti.
IMPORTANTE
Carlo Gavazzi no se responsabiliza del uso incorrecto del producto o
de los daños ocasionados por un uso incorrecto del mismo y /o por
el uso del producto sin tener en cuenta los límites de funcionamiento
especificados. Los equipos, especificaciones y datos recogidos en este
documento están sujetos a cambios sin previo aviso. El equipo debe
usarse por personal cualificado y bajo su responsabilidad y riesgo. En
caso de necesitar más información sobre la instalación, funcionamiento
o mantenimiento del equipo que no se refleje en este documento, pón-
gase en contacto con un distribuidor autorizado de Carlo Gavazzi. La
información detallada en este documento no se considera vinculante en
ninguna garantía del producto.
WICHTIG
Carlo Gavazzi übernimmt keine Haftung für fehlerhafte Bedienung des
Produkts sowie für Schäden, die aus unsachgemäßer Verwendung des
Produkts und/oder dem Einsatz des Produkts außerhalb der angege-
benen Grenzbetriebsdaten resultieren. Die in diesem Dokument bes-
chriebenen Produkte, Spezifikationen und technischen Daten können
jederzeit ohne vorherige Ankündigung geändert werden. Das Produkt ist
nur für die Verwendung durch qualifiziertes Fachpersonal nach eigenem
Ermessen und auf eigenes Risiko vorgesehen. Wenn Sie Informationen
zur Installation, zum Betrieb oder zur Wartung des Produkts benötigen,
die nicht in dieser Anleitung enthalten sind, wenden Sie sich mit Ihrer
Frage an einen autorisierten Vertriebspartner von Carlo Gavazzi. Die
Informationen in diesem Dokument sind nicht bindend hinsichtlich der
Produktgewährleistung.
IMPORTANT
Carlo Gavazzi ne peut être tenu responsable d’une exploitation incorrecte
du produit ou d’avaries résultant d’une utilisation incorrecte du produit
et/ou hors des tolérances de fonctionnement spécifiées. Les produits,
caractéristiques et données décrites dans le présent document peuvent
changer sans préavis. L’utilisation de ce produit est destinée à un per-
sonnel qualifié qui l’exploite à sa guise et à ses propres risques. Pour
plus amples informations concernant l’installation, le fonctionnement ou
la maintenance du produit et ne figurant pas dans ce document, consulter
un concessionnaire agréé Carlo Gavazzi. Les informations contenues
dans ce document ne constituent une obligation de garantie de quelcon-
que nature du produit.
IMPORTANTE
Carlo Gavazzi non può essere ritenuta responsabile per un malfunziona-
mento o danni derivanti da un uso improprio del prodotto e/o utilizzo del
prodotto al di fuori dei suoi limiti operativi specificati. Prodotti, specifiche
e dati in questo documento sono soggette a modifiche senza preavvi-
so.Il prodotto è destinato ad essere utilizzato da personale qualificato
a propria discrezione e rischio. Se avete bisogno di informazioni su
installazione, funzionamento o manutenzione del prodotto non riportate
in questo documento, dovete fare riferimento al personale autorizzato
Carlo Gavazzi. Le informazioni contenute in questo documento non sono
considerate vincolanti per alcuna garanzia sul prodotto.
CARLO GAVAZZI LTD.
BLB042, Bulebel Industrial Estate,
Zejtun
ZTN 3000, Malta
www.gavazziautomation.com
ВАЖНО
重要事项
Carlo Gavazzi не отвечает за некорректную работу или повреждение
УПП вследствие ненадлежащего применения и/или эксплуатации
УПП за пределами паспортных характеристик. Изделия,
характеристики и другие сведения в настоящем документе могут быть
изменены без уведомления. УПП предназначено для эксплуатации
квалифицированным персоналом на его риск. За отсутствием какой-
либо информации по монтажу, эксплуатации или обслуживанию
изделий в настоящем документе следует обратиться к официальному
представителю Carlo Gavazzi. Информация в настоящем документе
не является основанием для применения каких-либо гарантийных
условий.
对于不当使用本产品和/或在规定的工作限值之外使用本产品而造成的产
品操作错误或损坏,Carlo Gavazzi 不承担任何责任。本文档中的产品、
规格和数据如有变更,恕不另行通知。本产品应由合格人员自行斟酌使
用并承担风险。如果您需要有关本文档未涵盖的产品安装、操作或维护
信息,应告知 Carlo Gavazzi 授权代表。本文档中的信息不应视为对任何
产品保修都有约束力。
!
!
DIMENSIONS (MM) | MÅL (MM) | DIMENSIONES (MM) | ABMESSUNGEN (MM) | DIMENSIONS (MM) | DIMENSIONI (MM) | РАЗМЕРЫ (ММ) | 尺寸 (MM)
295mm[11.61'']
220mm[8.66'']
204mm[8.03'']
134.5mm[5.30''] 134.5mm[5.30'']
10mm[0.39'']20mm[0.79'']
4.5mm[
0.18'']
190mm[7.48'']
70.8mm[2.79'']60mm[2.36'']
75mm[2.95'']
M5 Tap
220mm[8.66'']
204mm[8.03'']
355mm[13.98'']
164.5mm[6.48'']164.5mm[6.48'']
20mm[0.79''] 10mm[0.39'']
190mm[7.48'']
60mm[2.36''] 70.8mm[2.79'']
75mm[2.95'']M5 Tap
130
4.5mm[
0.18'']
127mm[5.00"] 61mm[2.40"]
55mm[2.17"] 82.4mm[3.24"]
81.5mm[3.21"]
251.5mm[9.90"]
61.5mm[2.42"]
(MAX)
32mm [1.26”]
127mm[5.00"]
61.5mm[2.42"]
251.5mm[9.90"]
82.4mm[3.24"]
81.5mm[3.21"]53mm[2.09"]
(MAX)
RVPM1200500FPF
RVPM1200500FP
RVPM3400800FP RVPM3400800FPF
PANEL CUT-OUT / MOUNTING HOLE
204mm[8.03"]
269mm[10.60"]
6-M4 Tap
THRU
141mm[5.55"]
255mm[10.04"]
Cutting Line
87mm[3.43"]
134.5mm[5.30"] 134.5mm[5.30"]
182mm[7.17"]
17mm[0.67"]
27mm[1.06"]
PANEL CUT-OUT / MOUNTING HOLE
87mm[3.43"] 242mm[9.53"]
255mm[10.04"]
THRU
Cutting Line
6-M4 Tap
164.5mm[6.48"] 164.5mm[6.48"]
77mm[3.03"]
204mm[8.03]
46mm[1.81"] 141mm[5.55"]
RVPM1200500FPF
RVPM3400800FPF
HEATSINK VERSION | VARMEAFLEDERVERSION | VERSIÓN CON DISIPADOR
| KÜHLKÖRPERAUSFÜHRUNG | VERSION HEATSINK VERSIONE | CON
DISSIPATORE | ВЕРСИЯ С ТЕПЛООТВОДОМ | 散热器版本
UK Importer Address:
Carlo Gavazzi UK Ltd
4.4 Frimley Business Park,
Frimley, Camberley, Surrey, GU167SG
CONNECTION DIAGRAM | TILSLUTNINGSDIAGRAMMER | DIAGRAMA DE CONEXIONES | ANSCHLUSSDIAGRAMME | DIAGRAMME DE RACCORDEMENT | DIAGRAMMA DELLE CONNESSIONI | СХЕМА ПОДКЛЮЧЕНИЯ | 连接图
RVPM3400800... RVPM1200500...
Modbus
PLC
B+
A-
GND
T1
T2
T3 BK BU
FG
L
Motor
3~
WH RD
Ferrite core
Ферритовый сердечник
铁氧体磁芯
FG
FGL2L1
N
L3
Modbus
PLC
B+
A-
GND
C1
C2 T1 T2 T3
FG
FG
Motor
3~
FGL2L1
L1 L2 L3
DC Reactor
PFC reactor
M5 x 4
M6 x 4
Modbus
PLC
B+
A-
GND
T1
T2
T3 BK BU
FG
L
Motor
3~
WH RD
Ferrite core
Ферритовый сердечник
铁氧体磁芯
FG
FGL2L1
N
L3
Modbus
PLC
B+
A-
GND
C1
C2 T1 T2 T3
FG
FG
Motor
3~
FGL2L1
L1 L2 L3
DC Reactor
PFC reactor
M5 x 4
M6 x 4
Attention | Vigtigt | Atención | Achtung | Attention | Attenzione | ВНИМАНИЕ! | 注意:
Make sure that the cooling device is dimensioned and fixed to the plate in a way to dissipate the heat while keeping the tem-
perature of the plate below 70°C in the various operating conditions and that the overheating alarm does not intervene. | Sørg
for, at køleenheden er dimensioneret og fastgjort til pladen på en sådan måde, at varmen spredes, mens temperaturen på pladen
holdes under 70 °C under de forskellige driftsforhold, og at alarmen for overophedning ikke griber ind. | Asegúrese de que el dis-
positivo de refrigeración está dimensionado y fijado a la placa de una forma que disipe el calor, manteniendo la temperatura de la
placa por debajo de 70 °C en las diversas condiciones de funcionamiento y sin que la alarma de sobrecalentamiento se dispare. |
Vergewissern Sie sich, dass das Kühlgerät so dimensioniert und an der Platte befestigt ist, dass es die Wärme abführt und dabei die
Plattentemperatur in den verschiedenen Betriebszuständen unter 70 °C hält und der Überhitzungsalarm nicht auslöst. | S’assurer que
le dispositif de refroidissement est dimensionné et fixé à la plaque de manière à dissiper la chaleur tout en maintenant la température
de la plaque en dessous de 70 ° C dans les différentes conditions de fonctionnement et que l’alarme de surchauffe n’intervienne
pas. | Accertarsi che il dispositivo di raffreddamento sia dimensionato e fissato alla piastra in modo da dissipare il calore man-
tenendo la temperatura della piastra al di sotto di 70°C nelle varie condizioni di funzionamento e che l’allarme di surriscaldamento
non intervenga. | УБЕДИТЕСЬ, ЧТО ОХЛАЖДАЮЩЕЕ УСТРОЙСТВО ИМЕЕТ ТАКИЕ РАЗМЕРЫ И КРЕПИТСЯ К
ПЛАСТИНЕ ТАКИМ ОБРАЗОМ, ЧТОБЫ РАССЕИВАТЬ ТЕПЛО, ПОДДЕРЖИВАЯ ТЕМПЕРАТУРУ ПЛАСТИНЫ НИЖЕ
70°C ПРИ РАЗЛИЧНЫХ УСЛОВИЯХ РАБОТЫ, А ТАКЖЕ ЧТО НЕ ПОЯВЛЯЕТСЯ СИГНАЛ ТРЕВОГИ О ПЕРЕГРЕВЕ.
| 请确保冷却装置尺寸适当且散热板可以固定的位置,确保自身温度在不同的运行状况下可以低于70℃,且不会出发过热告警。
Make sure that the cooling device does not cause the formation of condensate on the inner surface of the plate. | Sørg for, at køleen-
heden ikke forårsager dannelse af kondens på pladens indre overflade. | Asegúrese de que el dispositivo de refrigeración no causa
la formación de condensación en la superficie interior de la placa. | Stellen Sie sicher, dass das Kühlgerät keine Kondensatbildung
auf der Innenfläche der Platte verursacht. | S’assurer que le dispositif de refroidissement ne provoque pas la formation de con-
densat sur la surface intérieure de la plaque. | Assicurarsi che il dispositivo di raffreddamento non provochi la formazione di
condensa sulla superficie interna della piastra. | УБЕДИТЕСЬ, ЧТО ОХЛАЖДАЮЩЕЕ УСТРОЙСТВО НЕ ВЫЗЫВАЕТ
ОБРАЗОВАНИЯ КОНДЕНСАТА НА ВНУТРЕННЕЙ ПОВЕРХНОСТИ ПЛАСТИНЫ. | 请确保冷却装置不会使散热板内表面结露。
Clean the contact surface of the RVPM aluminium plate and of the coldplate and ensure they couple precisely. | Rengør kontaktfladen på
RVPM-aluminiumspladen og koldpladen, og sørg for, at de sammenkobles nøjagtigt. | Limpie la superficie de contacto de la placa de aluminio
del RVPM y de la placa refrigerante. | Reinigen Sie die Kontaktfläche der RVPM-Aluminiumplatte und der Kälteplatte und stellen Sie sicher,
dass diese präzise koppeln. | Asegúrese también de que están acopladas con precisión. | Nettoyer la surface de contact de la plaque d’alu-
minium RVPM et de la plaque froide et s’assurer qu’ils s’accouplent avec précision. | L’uso di pasta termica o di prodotti simili, tra le super-
fici di contatto della RVPM e della piastra raffreddata, consente un migliore accoppiamento termico. | ПРИМЕНЕНИЕ ТЕРМОПАСТЫ
ИЛИ ПОДОБНОГО ИЗДЕЛИЯ МЕЖДУ КОНТАКТНЫМИ ПОВЕРХНОСТЯМИ УСТРОЙСТВА RVPM И ХОЛОДНОЙ
ПЛАСТИНЫ УЛУЧШАЕТ ТЕПЛОПЕРЕДАЧУ. | 在RVPM和散热板之间使用导热膏或类似产品,确保二者的热耦合效果更佳。
The use of thermal compound or similar product, between the contact surfaces of the RVPM and the coldplate allows better heat coupling.
| Brug af termisk kompound eller lignende produkt mellem kontaktfladerne på RVPM og koldpladen muliggør bedre varmeforbindelse. | El
uso de un compuesto térmico o un producto similar entre las superficies de contacto del RVPM y la placa refrigerante permite un mejor
acoplamiento térmico. | Die Verwendung von Wärmeleitpaste oder eines ähnlichen Produkts zwischen den Kontaktflächen des RVPM und
der Kälteplatte sorgt für eine bessere Wärmekopplung. | L’utilisation d’un composé thermique ou d’un produit similaire, entre les surfaces
de contact du RVPM et la plaque froide permet un meilleur couplage thermique. | L’uso di pasta termica o di prodotti simili, tra le superfici
di contatto della RVPM e della piastra raffreddata, consente un migliore accoppiamento termico. | ПРИМЕНЕНИЕ ТЕРМОПАСТЫ
ИЛИ ПОДОБНОГО ИЗДЕЛИЯ МЕЖДУ КОНТАКТНЫМИ ПОВЕРХНОСТЯМИ УСТРОЙСТВА RVPM И ХОЛОДНОЙ
ПЛАСТИНЫ УЛУЧШАЕТ ТЕПЛОПЕРЕДАЧУ. | 在RVPM和散热板之间使用导热膏或类似产品,确保二者的热耦合效果更佳。
Warning: the max tightening torque for screws for coldplate = 3Nm | Advarsel: maksimalt tilspændingsmoment for skruer til
koldplade = 3Nm | Advertencia: el par de apriete máximo para los tornillos de la placa refrigerante es de 3 Nm | Warnung: maximales
Anzugsdrehmoment für die Schrauben der Kälteplatte = 3 Nm. | Attention : le couple de serrage maximum des vis pour plaque froide =
3Nm | Avvertenza: la coppia massima di serraggio delle viti per la piastra raffreddata = 3Nm | Предупреждение: макс. момент затяжки
винтов для холодной пластины = 3 Нм | 警告:散热板螺栓的最大紧固扭矩为3Nm。
!
TERMINATIONS | TILSLUTNINGER | TERMINACIONES | ENDANSCHLÜSSE | CONNEXIONS DE SORTIE | TERMINALI | КЛЕММЫ | 端子
RVPM120500FP...
Function | НАЗНАЧЕНИЕ
| 功能
Marking |
МАРКИРОВКА
| 标志
Termination type | ТИП
КЛЕММЫ | 端子类型
Wire dimensions | РАЗМЕРЫ
ПРОВОДА | 电缆尺寸
Tightening torque
| МОМЕНТЫ
ЗАТЯЖКИ | 紧固扭矩
Line connections |
СОЕДИНЕНИЯ С ЛИНИЕЙ |
线路连接
L, N
M3.5 lug | ВЫВОД
ДЛЯ КАБЕЛЬНЫХ
НАКОНЕЧНИКОВ M3.5 |
M3.5 冷压接头
2.5 - 4 mm2
AWG 12...14
0.64 - 0.75 Nm
(5.6 - 6.5 lb in)
Load connections
| СОЕДИНЕНИЯ С
НАГРУЗКОЙ | 负载连接
T1, T2, T3 Faston
(6.35 x 0.8 mm)
2.5 - 4 mm2
AWG 12...14 -
Modbus
connections | СОЕДИНЕНИЯ
Modbus | Modbus连接
B+, A-, GND
Pluggable terminal M3 screw
ШТЕПСЕЛЬНЫЙ ВЫВОД
M3 端子接线用M3
x = 7.0 - 8.0 mm
0.2...1.5 mm2
AWG 28 - 12 (solid |
ОДНОЖИЛЬНЫЙ | 硬芯)
AWG 3 -12 (stranded |
СКРУЧЕННЫЙ | 多股)
0.5 Nm
(4.43 lb - in)
Functional ground |
ФУНКЦИОНАЛЬНОЕ
ЗАЗЕМЛЕНИЕ | 功能性接地
FG
M4 lug | ВЫВОД
ДЛЯ КАБЕЛЬНЫХ
НАКОНЕЧНИКОВ M4 | M4
冷压接头
1.5 - 2.5 mm2
AWG 14...16
0.64 - 0.75 Nm
(5.6 - 6.5 lb in)
PFC reactor
connections | СОЕДИНЕНИЯ
РЕАКТОРА С КОРРЕКЦИЕЙ
КОЭФФИЦИЕНТА
МОЩНОСТИ | 功率因数校正
器连接
WH (white | БЕЛЫЙ
| ), RD (red |
КРАСНЫЙ | ), BK
(black), BU (blue |
ЧЕРНЫЙ | )
Faston (6.35 x 0.8 mm)
2.5 mm2
AWG 14 -
X
TERMINATIONS | TILSLUTNINGER | TERMINACIONES | ENDANSCHLÜSSE | CONNEXIONS DE SORTIE | TERMINALI | КЛЕММЫ | 端子
RVPM3400800FP...
Function |
НАЗНАЧЕНИЕ | 功能
Marking |
МАРКИРОВКА | 标志
Termination type |
ТИП КЛЕММЫ |
子类型
Wire dimensions | РАЗМЕРЫ
ПРОВОДА | 电缆尺寸
Tightening torque |
МОМЕНТЫ ЗАТЯЖКИ |
固扭矩
Line connections |
СОЕДИНЕНИЯ С
ЛИНИЕЙ | 线路连接
L1, L2, L3
M3.5 lug | ВЫВОД
ДЛЯ КАБЕЛЬНЫХ
НАКОНЕЧНИКОВ
M3.5 | M3.5 冷压接头
2.5 - 4 mm2
AWG 12...14
0.64 - 0.75 Nm
(5.6 - 6.5 lb in)
Load connections
| СОЕДИНЕНИЯ С
НАГРУЗКОЙ | 负载
连接
T1, T2, T3
Modbus
connections |
СОЕДИНЕНИЯ
Modbus | Modbus连接
B+, A-, GND
Pluggable termi
nals M3 screw |
ШТЕПСЕЛЬНЫЕ
ВЫВОДЫ M3
ВИНТОВЫЕ | 端子接线
用M3螺栓
X = 7.0 - 8.0 mm
0.2...1.5 mm2
AWG 28 - 12 (solid |
ОДНОЖИЛЬНЫЙ | 硬芯)
AWG 30 - 12 (stranded |
СКРУЧЕННЫЙ | 多股)
0.5 Nm
(4.43 lb - in)
Functional ground
ФУНКЦИОНАЛЬНОЕ
ЗАЗЕМЛЕНИЕ | 功能
性接地
FG
M4 lug | ВЫВОД
ДЛЯ КАБЕЛЬНЫХ
НАКОНЕЧНИКОВ M4 |
M4 冷压接头
1.5 - 2.5 mm2
AWG 14...16
0.64 - 0.75 Nm
(5.6 - 6.5 lb in)
DC reactor
connections |
СОЕДИНЕНИЯ
РЕАКТОРА
ПОСТОЯННОГО
ТОКА | 直流电抗器连接
C1, C2 4 mm 2
AWG 12
Notes | Bemærkninger | Notas | Anmerkungen | Notes | Nota | Примечания | 备注
1) Use shielded cables. The cable shield must be connected to ground. | Brug afskærmede kabler. Kabelskærmen skal jordforbindes. | Utilice cables apantallados.
La pantalla del cable debe estar conectada a tierra. | Abgeschirmte Kabel verwenden. Der Kabelschirm ist an die Erde anzuschließen. | Utiliser des câbles blindés. Le
blindage du câble doit être connecté à la terre. | Utilizzare cavi schermati. La schermatura del cavo deve essere collegato alla terra. | Используйте экранированные
кабели. Оболочка кабеля должна быть заземлена. | 使用带屏蔽层的电缆。屏蔽层必须接地。
2) DC reactor is already provided with cables and terminations. | Jævnstrøms reaktoren er allerede forsynet med kabler og tilslutninger. | La reactancia de CC ya
dispone de cables y terminaciones. | Die Gleichstromdrossel ist bereits mit Kabeln und Abschlüssen versehen. | Le réacteur DC est déjà équipé de câbles et de
connexions de sortie. | L’induttanza DC è già provvista di cavi e terminali. | Реактор постоянного тока уже снабжен кабелями и клеммами. | 必须先行接好直流
电抗器的线缆和接线端子。
3) DC reactor requires M6 screws for mounting. | Jævnstrøms reaktoren kræver M6-skruer til montering. | La reactancia de CC requiere tornillos de M6 para su
montaje. | Die Gleichstromdrossel benötigt M6-Schrauben zur Montage. | Le réacteur DC nécessite des vis M6 pour le montage. | L’induttanza DC richiede viti M6
per il montaggio. | Для монтажа реактора постоянного тока требуются винты M6. | 直流电抗器的装配需要使用M6螺栓。
4) Max. depth screws for coldplate = 6mm. | Maks. dybde for skruer til koldplade = 6 mm. | Máx. profundidad de los tornillos para la placa refrigerante = 6 mm.
| Max. Tiefe Schrauben für Kälteplatte = 6 mm. | Max profondeur vis pour plaque froide = 6 mm. | Max. profondità viti per piastra fredda = 6mm. | Макс. глубина
винтов для холодной пластины = 6 мм. | 散热板的最大螺栓深度为6MM。
5) For RVPM...FPF models, provide the fans with a 24VDC 0.2A power supply (red - positive (+), black - negavitve (-) terminal). | For RVPM...FPF-modeller skal
ventilatorerne have en 24VDC 0.2A strømforsyning (rød - positiv (+), sort - negativ (-) tilslutning). | Para los modelos RVPM...FPF, alimente los ventiladores con una
fuente de alimentación de 24 VCC 0,2 A (terminal rojo = positivo [+], terminal negro = negativo [-]). | Bei den Modellen RVPM...FPF müssen die Lüfter mit einer 24 VDC
0,2 A Str`mversorgung versorgt werden (rot - positive (+), schwarz - negative (-) Klemme). | Pour les modèles RVPM ... FPF, fournir les ventilateurs avec connexion
au réseau électrique 24VDC 0,2A (borne rouge - positive (+), noire - négative (-). | Per i modelli RVPM...FPF, fornire alle ventole un’alimentazione da 24VDC 0,2A
(terminale rosso - positivo (+), nero - negativo (-)). | Для моделей RVPM...FPF обеспечьте кулеры с питанием 24 В пост. ток 0,2 A (красный - положительная (+),
черный - отрицательная (-) клемма). | 对于RVPM...FPF型号产品,需要额外安装一台供电参数为24VDC 0.2A(红色正极+;黑色负极-至端子)的风扇。
X
SERIAL NETWORK CONNECTION | SERIEL NETVÆRKSFORBINDELSE | CONEXIÓN RED SERIE | SERIELLER NETZWERKANSCHLUSS | CONNEXION RÉSEAU SÉRIE | CONNESSIONE DI RETE SERIALE | ПОСЛЕДОВАТЕЛЬНОЕ ПОДКЛЮЧЕНИЕ К СЕТИ |
行网络连接
For the serial connection use a three - wire shielded cable. For large networks, install a 120 ohm ¼ W resistor between terminals B + and A - on the last drive or device connected, to avoid possible communication problems. | Til seriel forbindelse skal du bruge et afskærmet kabel med tre ledninger. For store netværk skal du installere et 120 ohm ¼ W
modstandselement mellem tilslutningerne B + og A - på det sidste drev eller den tilsluttede enhed for at undgå mulige kommunikationsproblemer. | Para conectar en serie utilice un cable apantallado de tres hilos. Para grandes redes, instale una resistencia de 120 ohmios (¼ W) entre los terminales B + y A - en la última unidad o dispositivo conectado, para
evitar posibles problemas de comunicación. | Verwenden Sie für die serielle Verbindung ein dreiadriges abgeschirmtes Kabel. Zur Vermeidung möglicher Kommunikationsprobleme installieren Sie bei großen Netzwerken einen 120-Ohm-¼-W-Widerstand zwischen den Klemmen B + und A - am letzten angeschlossenen Antrieb oder Gerät. | Pour la connexion
série, utiliser un câble blindé à trois fils. Pour les grands réseaux, installer une résistance de 120 ohms ¼ W entre les bornes B + et A - sur le dernier variateur ou appareil connecté, pour éviter des problèmes de communication. | Per la connessione seriale utilizzare un cavo schermato a tre fili. Per le reti di grandi dimensioni, installare una resistenza da 120
ohm ¼ W tra i morsetti B + e A - sull’ultimo drive o dispositivo collegato, per evitare possibili problemi di comunicazione. | Для последовательного подключения используйте трёхжильный экранированный кабель. Для больших сетей установите резистор 120 Ом ¼ Вт между клеммами B + и A - на последнем подключенном приводе или устройстве
во избежание возможных проблем со связью. | 串行连接需要用到三股屏蔽电缆。网络规模过大时,需要在最后一个驱动器或已连接装置的端子B+和A-之间安装一只120Ω(1/4W)的电阻,避免出现通讯问题。
Shield
Оболочка
屏蔽层
PLC
RVPM RVPM
R = 120 ohm
GND
GND
B+
B+
A-
A-
¼ W
Notes | Bemærkninger | Notas | Anmerkungen | Notes | Nota | Примечания | 备注
1) Use shielded cables. The cable shield must be connected to ground. | Brug afskærmede kabler. Kabelskærmen skal jordforbindes. | Utilice cables apantallados. La pantalla del cable debe estar conectada a tierra. | Abgeschirmte Kabel verwenden. Der Kabelschirm
ist an die Erde anzuschließen. | Utiliser des câbles blindés. Le blindage du câble doit être connecté à la terre. | Utilizzare cavi schermati. La schermatura del cavo deve essere collegato alla terra. | Используйте экранированные кабели. Оболочка кабеля должна быть
заземлена. | 使用带屏蔽层的电缆。屏蔽层必须接地。|
2) Connect ferrite cores (not provided with RVPM on the input (L, N) and output (T1, T2, T3) cables to improve EMC performance. | Tilslut ferritkerner (ikke leveret med RVPM på indgangs- (L, N) og udgangskabler (T1, T2, T3) for at forbedre EMC ydeevnen. | Conecte los
núcleos de ferrita (no proporcionados con el RVPM en los cables de entrada (L, N) y de salida (T1, T2, T3) para mejorar las prestaciones que afectan a la CEM. | Zur Verbesserung der EMV-Leistung schließen Sie Ferritkerne (nicht im Lieferumfang des RVPM enthalten)
an die Eingangs- (L, N) und Ausgangskabel (T1, T2, T3) an, um die . | Connecter des noyaux de ferrite (non fournis avec RVPM sur les câbles d’entrée (L, N) et de sortie (T1, T2, T3) pour améliorer les performances CEM. | Collegare il nucleo di ferrite (non fornito con il
RVPM sul segnale di input (L, N) e di output (T1, T2, T3) per migliorare le prestazioni dell’EMC. | Подсоедините ферритовые сердечники (не входят в комплект устройства RVPM к кабелям входа (L, N) и выхода (T1, T2, T3) для улучшения ЭМС. | 连接铁氧体磁芯【(
未随RVPM提供可改善电磁兼容性能的输入端(L, N)和输出端(T1, T2, T3)电缆】。
3) PFC reactor is already provided with cables and terminations. | PFC-reaktoren er allerede forsynet med kabler og tilslutninger. | La reactancia CFP ya dispone de cables y terminaciones. | Die PFC-Drossel ist bereits mit Kabeln und Abschlüssen versehen. | Le réacteur
PFC est déjà équipé de câbles et de connexions. | L’induttanza PFC è già provvista di cavi e terminali. | Реактор с коррекцией коэффициента мощности уже снабжен кабелями и клеммами. | 必须先行接好功率因数校正器的线缆和接线端子。
4) PFC reactor requires M5 screws for mounting. | PFC-reaktoren kræver M5-skruer til montering. | La reactancia CFP requiere tornillos de M5 para su montaje. | Die PFC-Drossel benötigt M5-Schrauben zur Montage. | Le réacteur PFC nécessite des vis M5 pour le
montage. | L’induttanza PFC richiede viti M5 per il montaggio. | Для монтажа реактора с коррекцией коэффициента мощности требуются винты M5. | 功率因数校正器的装配需要使用M5螺栓。
5) Max. depth screws for coldplate = 6mm. | Maks. dybde for skruer til koldplade = 6 mm. | Máx. profundidad de los tornillos para la placa refrigerante = 6 mm. | Max. Tiefe Schrauben für Kälteplatte = 6 mm. | Max profondeur de vis pour plaque froide = 6 mm. | Max.
profondità viti per piastra fredda = 6mm. | Макс. глубина винтов для холодной пластины = 6 мм. | 散热板的最大螺栓深度为6MM。
6) For RVPM...FPF models, provide the fans with a 24VDC 0.2A power supply (red - positive (+), black - negative (-) terminal). | For RVPM...FPF-modeller skal ventilatorerne have en 24VDC 0.2A strømforsyning (rød - positiv (+), sort - negativ (-) tilslutning). | Para los
modelos RVPM...FPF, alimente los ventiladores con una fuente de alimentación de 24 VCC 0,2 A (terminal rojo = positivo [+], terminal negro = negativo [-]). | Bei den Modellen RVPM...FPF müssen die Lüfter mit einer 24 VDC 0,2 A Stromversorgung versorgt werden
(rot - positive (+), schwarz - negative (-) Klemme). | Pour les modèles RVPM ... FPF, équiper les ventilateurs d’une alimentation 24VDC 0,2A (borne rouge - positive (+), noire - négative (-)). | Per i modelli RVPM...FPF, fornire alle ventole un’alimentazione da 24VDC 0,2A
(terminale rosso - positivo (+), nero - negativo (-)). | Для моделей RVPM...FPF обеспечьте кулеры с питанием 24 В пост. ток 0,2 A (красный - положительная (+), черный - отрицательная (-) клемма). | 对于RVPM...FPF型号产品,需要额外安装一台供电参数为24VDC
0.2A(红色正极+;黑色负极-至端子)的风扇。|
KEY | TAST | LEYENDA | SCHLÜSSEL|CLÉ |CHIAVE|УСЛОВНЫЕ ОБОЗНАЧЕНИЯ | 关键
A
B
B
C
ACooling device - coldplate (example) | Køleenhed - koldplade (eksempel) |
Dispositivo de refrigeración - placa refrigerante (ejemplo) | Kühlgerät - Kälteplatte
(Beispiel) | Dispositif de refroidissement - plaque froide (exemple) | Dispositivo di raf-
freddamento - piastra raffreddata (esempio) | ОХЛАЖДАЮЩЕЕ УСТРОЙСТВО
- ХОЛОДНАЯ ПЛАСТИНА (ПРИМЕР) | 散热装置 - 散热板(示例)
BHoles / screws for cooling device fitting (6 holes M5 max depth 6mm) | Huller/skruer
til køleenhedens montering (6 huller M5 maks. dybde 6 mm) | Agujeros / tornillos
para el montaje del dispositivo de refrigeración (6 agujeros M5 con prof. máx. de
6 mm) | Bohrungen / Schrauben für Kältegerät-Fitting (6 M5-Bohrungen max. Tiefe
6 mm) | Trous / vis pour le montage du dispositif de refroidissement (6 trous M5
profondeur max 6 mm) | Fori / viti per il montaggio del dispositivo di raffreddamento
(6 fori M5 profondità max 6mm) | ОТВЕРСТИЯ / ВИНТЫ ДЛЯ КРЕПЛЕНИЯ
ОХЛАЖДАЮЩЕГО УСТРОЙСТВА (6 ОТВЕРСТИЙ М5 МАКС. ГЛУБИНОЙ
6 ММ) | 用于固定冷却装置的预置孔/螺栓(6孔M5,最大深度6MM)
CRVPM aluminium plate | RVPM-aluminiumsplade | Placa de aluminio del RVPM
| RVPM-Aluminiumplatte | Plaque en aluminium RVPM | Piastra di alluminio RVPM |
АЛЮМИНИЕВАЯ ПЛАСТИНА RVPM | RVPM铝板
  • Page 1 1
  • Page 2 2

CARLO GAVAZZI RVPM3400800FPF El manual del propietario

Tipo
El manual del propietario
Este manual también es adecuado para