Installation Instructions
for your new
Before you begin - Read these instructions completely and carefully.
IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installer – Be sure to leave these instructions with the end user.
Note to end user – Keep these instructions with your Owner’s Manual for future reference.
RAVWPT15
Wall Plenum
31-5000506 Rev. 0 08-20 GEA
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Installation Overview
Unit
RAVDPLAT
Part B Inside
Wall Plenum
Part A Outside
Wall Plenum
Properly sized header is
required for structural
support. Proper caulking
and flashing are required
NOTE: The plenum has a
wax cardboard weather
cover. Do not remove
this cover until ready
to install the grille
(RAVAL3)
Exterior/
Outside Wall
Parts Included
There are two parts to a Wall Plenum:
Part A - Outside Plenum
Installed so the large opening is on the bottom and the drain holes
and keyhole slots for attaching the grille are on the outside of the
building.
Part B - Inside Plenum
Installed so the large opening is on the bottom and the top and
side flanges are against the inside wall of the building.
Materials Needed (Field Supplied Parts)
Exterior silicone caulk (recommended)
Flashing
Shims
Header Material/Wall Studs
1” - 3” Screws to attach the plenum assembly to the wall
studs.
Grille Kit RAVAL3 (sold separately)
YOUR WALL PLENUM WILL ONLY WORK IF INSTALLED CORRECTLY. MAKE SURE TO INSTALL THE
WALL PLENUM IN THE CORRECT ORIENTATION AS SHOWN IN THE ILLUSTRATIONS. For easier
installation, Grille Kit RAVAL3 should be installed at time of Wall Plenum Installation.
Part B Inside
Wall Plenum
Large
opening
Large
opening
Part A outside
Wall Plenum
2
Installation Instructions
STEP 1
Outside Wall Plenum Opening
Ensure the outside wall plenum opening is properly
framed and square per the diagram shown below.
IMPORTANT: The wall plenum is not designed to carry
structural loads. A proper header must be built into the
rough opening and a proper lintel must be installed to
support brick or other masonry materials. The plenum
requires flashing, shimming and caulking for a weather-
resistant installation.
It is the responsibility of the contractor to properly
install the plenum and meet building code
requirements.
24”
32”
STEP 2
Setting the Plenum Depth
Measure the rough opening depth
If the rough opening depth is less than 7.5”, proceed
to STEP 3. If the rough opening depth is more than
7.5”, remove and discard the front 2 screws on the
plenum divider and loosen the rear 2 screws. This will
allow Part A and Part B to slide apart.
Adjust the plenum depth by sliding Part A and Part B
apart. Set plenum 1/4” deeper than the rough opening
to allow for a caulking edge on the exterior.
Tighten the rear screws.
Inside Wall
Building rough opening
Outside Wall
D
Front screws
Rear screws
D + 1/4”
3
Installation Instructions
STEP 4
Plenum Installation
NOTES:
A properly sized header and rough in framing must
conform to all national and local building codes.
Before caulking and permanent attachment, dry
fit plenum into the rough opening to check for fit,
squareness and level.
Caulk the wall plenum on
the rough opening side of
the wall plenum flange.
Proper Header*
Direction of installation
Proper Flashing*
Proper Flashing*
Building rough
opening
Outside
Wall
Proper Caulking*
Direction of installation
Proper Caulking*
Proper Header*
Building
rough
opening
* Field Supplied Parts
STEP 3
Install Grille Kit RAVAL3 (not included) on the Outside Plenum
NOTE: The Grille Kit RAVAL3 is best installed onto the
Outside Plenum (Part A) prior to the wall plenum being
installed into the building. Grille installation is easier
at this point and will help keep the wall plenum square
during installation.
If you are not installing the grille at this time be sure the
plenum is square when installed in the opening and do
not remove the weather cover.
NOTE: Refer to instructions included in the Grille
Kit RAVAL3 for proper installation procedure.
Part A Outside
Wall Plenum
RAVAL3
RAVAL3
Side View
Part A Outside
Wall Plenum
Installation Instructions
4
Printed in China
STEP 4
Plenum Installation (cont.)
Secure plenum using the field supplied screws through
the four provided slots in the plenum front face.
Caulk may need to be applied to the outside of the
building along all top, bottom and sides of the plenum
to ensure a water tight seal.
If additional screws are used to secure the inside of the
wall plenum to the rough opening framing, only drive
screws through the vertical sides of the wall plenum.
Water may penetrate into framing if screws are driven
into the bottom of the plenum. See Detail A.
Apply caulk on the bottom of the plenum at the seam
between part A and part B, running the caulk 3 inches
up each side.
* Field Supplied Parts
Proper Caulking*
All 4 sides
Screws*
A
A
A
A
Detail A
Four places
Instructions d’installation
pour votre nouveau plénum
mural
Avant de commencer – Lisez ces instructions attentivement et en entier.
IMPORTANT – RESPECTEZ TOUS LES CODES ET RÈGLEMENTS APPLICABLES. Remarque à
l’intention de l’installateur – Assurez-vous de remettre ces instructions au utilisateur final.
Note à l’utilisateur final - Conservez ces instructions avec le manuel du propriétaire afin de pouvoir
vous y reporter ultérieurement.
RAVWPT15
31-5000506 Rev. 0 08-20 GEA
GE est une marque de commerce de General Electric Company. Fabriqué sous licence d’utilisation de marque.
Aperçu de l’installation
Unit
RAVDPLAT
Part B Inside
Wall Plenum
Part A Outside
Wall Plenum
Properly sized header is
required for structural
support. Proper caulking
and flashing are required
NOTE: The plenum has a
wax cardboard weather
cover. Do not remove
this cover until ready
to install the grille
(RAVAL3)
Exterior/
Outside Wall
Liste des pièces
Un plénum mural comprend deux parties :
Partie A – Plénum extérieur
Installez de manière à ce que la grande ouverture se retrouve au
bas et que les trous de drainage et les fentes piriformes fixant la
grille se retrouvent à l’extérieur du bâtiment.
Partie B – Plénum intérieur
Installé de manière à ce que la grande ouverture soit au bas
et que la partie supérieure et les collerettes d’encastrement se
trouvent contre le mur intérieur du bâtiment.
Matériel requis (pièces sur le terrain)
Matériau d’étanchéité au silicone (recommandé)
• Solin
• Entretoises
Matériau de linteau/poteau de cloison
Vis de 1 po – 3 po pour fixer le plénum aux poteaux de cloison.
Ensemble de grille RAVAL3 (vendu séparément)
LE PLÉNUM MURAL FONCTIONNERA UNIQUEMENT S’IL EST INSTALLÉ CORRECTEMENT. GRILLE AVEC
4 VIS DE MONTAGE INSTALLÉES EN USINE. Pour faciliter l’installation, l’ensemble de grille RAVAL3 doit être installé au
moment de l’installation du plénum mural.
Partie B du plénum
mural intérieur
Grande
ouverture
Grande
ouverture
Partie A du plénum
mural extérieur
Un linteau de taille
adéquate est requis pour
le soutien structural. La
pose d’un solin et d’un
matériau d’étanchéité
adéquat est requise.
REMARQUE: le plénum
dispose d’un capot protecteur
en carton ciré. Ne retirez pas
ce couvercle jusqu’à ce que
vous soyez prêt à installer la
grille (Ens. n° RAVAL3).
Appareil
Partie B
Plénum mural
intérieur
Extérieur/ Mur
extérieur
Partie A
Plénum mural
extérieur
2
Instructions d’installation
ÉTAPE 1
Ouverture de plénum de mur extérieur
Assurez-vous que la structure de l’ouverture de plénum de
mur extérieur est adéquate et à l’équerre, comme montré
dans le schéma ci-dessous.
IMPORTANT: Le plénum de mur n’est pas conçu pour
supporter une charge structurelle. Un chevêtre adéquat
doit être construit dans l’ouverture brute et un linteau
doit être installé pour supporter la brique ou les autres
matériaux de maçonnerie. Le plénum requiert un solin, un
calage et un calfeutrant pour étanchéiser l’installation.
L’entrepreneur est responsable d’installer correctement
le plénum en conformité avec les exigences du code du
bâtiment.
24”
32”
ÉTAPE 2
Ajustement de la profondeur du plénum
Mesurez la profondeur brute de l’ouverture
Si la profondeur brute de l’ouverture est inférieure à 19 cm
(7,5 po), passez à l’ÉTAPE 3. Si la profondeur brute de
l’ouverture est supérieure à 19 cm (7,5 po), retirez et jetez
les deux vis frontales du diviseur de plénum et dévissez les
2 vis arrière. Ceci permettra de faire glisser et séparer les
parties A et B.
Ajustez la profondeur du plénum en faisant glisser et
séparer les parties A et B. Placez le plénum sur 0,6 cm (1/4
po) plus profond que l’ouverture brute pour permettre le
calfeutrage à l’extérieur.
Serrez les vis arrière.
Mur intérieur
Ouverture
brute dans
le bâtiment
Mur extérieur
D
Vis frontales
Vis arrière
D + 1/4”
3
Instructions d’installation
ÉTAPE 4
Installation du plénum
REMARQUES:
Le linteau et l’ossature hors toute de dimensions
adéquates doivent être conformes aux codes du bâtiment
locaux et nationaux.
Avant la pose du matériau d’étanchéité et la mise en
place permanente, ajustez à sec le plénum extérieur
dans l’ouverture brute et vérifiez l’ajustement, la mise à
l’équerre et la mise au
niveau.
Appliquez un calfeutrant
sur le plénum mural
sur la partie brute
de l’ouverture de la
collerette d’encastrement
du plénum mural.
Linteau adéquat*
Instruction d’installation
Solin adéquat*
Solin adéquat*
Ouverture
brute dans
le bâtiment
Mur
extérieur
Calfeutrement adéquat*
Instruction d’installation
Calfeutrement adéquat*
Linteau adéquat*
Ouverture
brute dans
le bâtiment
* Pièce fournie sur le terrain
ÉTAPE 3
Installer l’ensemble de grille RAVAL3 (non compris) sur le plénum extérieur
REMARQUE: il est préférable d’installer l’ensemble de grille
RAVAL3 sur le plénum extérieur (Partie A) avant d’installer le
plénum mural sur le bâtiment. L’installation de la grille est plus
facile à ce moment et cela aidera à garder le plénum mural à
l’équerre pendant l’installation.
Si vous n’installez pas la grille à ce moment, assurez-vous
que le
plénum est à l’équerre lorsqu’il est inséré dans
l’ouverture et ne retirez pas le couvercle .
REMARQUE : reportez-vous aux instructions comprises
dans l’ensemble de grille RAVAL3 pour connaître la
procédure d’installation adéquate.
Part A Outside
Wall Plenum
RAVAL3
RAVAL3
Vue latérale
Part A Outside
Wall Plenum
Instructions d’installation
4
Imprimé aux China
ÉTAPE 4
Installation du plénum
(suite)
Fixez fermement le plénum à l’aide des vis fournies sur
place en les insérant dans les quatre fentes prévues sur la
face du plénum.
L’application d’un calfeutrant peut être nécessaire à
l’extérieur du bâtiment sur tout le pourtour du plénum afin
d’assurer son étanchéité.
Si vous devez utiliser d’autres vis pour fixer fermement
l’intérieur du plénum mural à l’ouverture brute de la
structure, ne les insérer que sur les côtés verticaux du
plénum mural. L’eau peut pénétrer dans la structure si les
vis sont insérées au bas du plénum. Consultez le Détail A.
Appliquez le calfeutrant au bas du plénum, au joint situé
entre les parties A et B et en l’appliquant sur 7,6 cm (3 po)
vers le haut, de chaque côté.
* Pièce fournie sur le terrain
Calfeutrant
adéquat* sur les
4 côtés
Vis
A
A
A
A
Détails A
Quatre endroits
Instrucciones de Instalación
de su nuevo
Plénum de Pared
Antes de comenzar – Lea estas instrucciones completamente y de forma detenida.
IMPORTANTE - CUMPLA CON TODOS LOS CÓDIGOS Y ORDENANZAS GUBERNAMENTALES. Nota para el
Instalador – Asegúrese de entregarle estas instrucciones al usuario final.
Nota para el usuario final – Guarde estas instrucciones con su Manual del Usuario para referencia futura.
RAVWPT15
31-5000506 Rev. 0 08-20 GEA
GE Appliances es una marca registrada de la Empresa General Electric. Fabricado bajo licencia de la marca registrada.
Descripción General de la Instalación
Unit
RAVDPLAT
Part B Inside
Wall Plenum
Part A Outside
Wall Plenum
Properly sized header is
required for structural
support. Proper caulking
and flashing are required
NOTE: The plenum has a
wax cardboard weather
cover. Do not remove
this cover until ready
to install the grille
(RAVAL3)
Exterior/
Outside Wall
Piezas Incluidas
Los Plénum de Pared cuentan con dos piezas:
Pieza A—Plénum Externo
Instalado de forma que la apertura grande esté en la parte inferior
y que los agujeros de drenaje y las ranuras con forma de cerradura
para adherir la rejilla estén en la parte exterior de la edificación.
Pieza B – El Plénum Interno
Instalado de forma que la apertura grande esté en la parte inferior
y que las bridas superiores y laterales queden contra la pared
interior de la edificación.
Materiales Necesarios (Piezas Específicas
Suministradas)
Sellador de Silicona (recomendado)
• Plancha
• Cuñas
Material de la Viga/ Montajes de Pared
Tornillos de 1” a 3” para adherir el ensamble del plénum a los
montajes de pared.
Kit de Rejilla RAVAL3 (se vende aparte)
SU PLÉNUM DE PARED SÓLO FUNCIONARÁ SI ES INSTALADO DE FORMA CORRECTA. ASEGÚRESE
DE INSTALAR EL PLÉNUM DE PARED EN LA ORIENTACIÓN CORRECTA COMO SE MUESTRA EN LAS
ILUSTRACIONES. A fin de facilitar la instalación, el Kit de Rejilla RAVAL3 deberá ser instalado en el momento en que se instale el
Plénum de Pared.
Pieza B dentro del
Plénum de Pared
Abertura
Grande
Abertura
Grande
Pieza A afuera del
Plénum de Pared
Se requiere una viga del
tamaño adecuado para el
soporte de la estructura.
Se requiere una lámina y
sellador adecuados.
NOTA: El plénum cuenta
con un protector de cartón
encerado. No retire este
protector hasta que esté
preparado para instalar la
rejilla (Kit nº RAVAL3).
Unidad
Pieza B
Plénum de la
Pared Interna
Exterior/ Pared
Externa
Pieza A
Plénum de la Pared Externa
2
Instrucciones de Instalación
PASO 1
Pieza A afuera del Plénum de Pared
Asegúrese de que la abertura exterior del plénum de
pared esté correctamente enmarcada y en ángulo recto de
acuerdo con el diagrama que figura a continuación.
IMPORTANTE: El plénum de pared no fue diseñado para
transportar cargas estructurales. Se deberá construir una
viga adecuada en la abertura rústica y se deberá instalar
un dintel apropiado que soporte ladrillos u otros materiales
de mampostería. El plénum requiere una plancha, cuñas y
sellador para una instalación resistente al clima.
Es responsabilidad del contratista instalar de forma
correcta el plénum y cumplir con los requisitos del
código de construcción.
24”
32”
PASO 2
Configuración de la Profundidad del
Plénum
Mida la profundidad de la abertura rústica
Si la profundidad de la abertura rústica es inferior a 7.5”,
proceda al PASO 3. Si la profundidad de la abertura rústica
es superior a 7.5”, retire los 2 tornillos frontales del divisor
del plénum y afloje los 2 tornillos traseros. Esto permitirá
que la Pieza A y la Pieza B se deslicen.
Ajuste la profundidad del plénum mientras aleja la Pieza
A y la Pieza B deslizándolas. Configure el plénum a una
profundidad de ¼” mayor que aquella de la apertura
rústica, a fin de poder contar con un extremo sellado en el
exterior.
Ajuste los tornillos traseros.
Pared interna
Abertura de
la Pared del
Edificio
Pared Externa
D
Tornillos
frontales
Tornillos traseros
D + 1/4”
3
Instrucciones de Instalación
PASO 4
Instalación del Plénum:
NOTAS
Una viga y una abertura del tamaño correctos en
el marco deberán cumplir con todos los códigos de
edificación nacionales y locales.
Antes de la aplicación del sellador y de la adhesión
permanente, seque la parte externa del plénum en la
abertura de la pared y controle el ajuste, encuadre y que
el plénum esté nivelado.
Selle el plénum de pared
sobre el lado de la abertura
rústica de la brida del plénum
de pared.
Viga Adecuada*
Dirección de la instalación
Plancha Adecuada*
Plancha Adecuada*
Abertura de
la Pared del
Edificio
Pared
Externa
Sellador Adecuado*
Dirección de la instalación
Sellador Adecuado*
Viga Adecuada*
Abertura de
la Pared del
Edificio
* Piezas Específicas Suministradas
PASO 3
Instale el Kit de Rejilla RAVAL3 (no incluido) en el Plénum Externo
NOTA: La instalación del Kit de Rejilla RAVAL3 es más
conveniente en el Plénum Externo (Pieza A), antes de la
instalación del plénum de pared en el edificio. La instalación
de la rejilla es más fácil en este punto, y ayudará a
mantener el plénum de pared, el cual se cuadró durante la
instalación.
Si no instalará la rejilla en esta oportunidad, asegúrese de
que el plénum quede cuadrado durante su instalación en la
abertura
y no retire la tapa de la entrada de clima.
NOTA: Para conocer los procedimientos adecuados de
instalación, consulte las instrucciones incluidas en el
Kit de Rejilla RAVAL3.
Part A Outside
Wall Plenum
RAVAL3
RAVAL3
Vista Lateral
Part A Outside
Wall Plenum
Instrucciones de Instalación
4
Impreso en China
* Piezas Específicas Suministradas
PASO 4
Instalación del Plénum:
(cont.)
Asegure el plénum insertando los tornillos suministrados a
través de las cuatro ranuras provistas sobre la cara frontal
del plénum.
Es posible que sea necesario aplicar sellador en la parte
exterior de la edificación, a lo largo del lado superior,
inferior y laterales del plénum, a fin de asegurar un sellado
hermético del agua.
Si se usan tornillos adicionales para asegurar la parte
interior del plénum de pared sobre el marco de la abertura
rústica, sólo coloque los tornillos a través de los laterales
verticales del plénum de pared. Es posible que el agua
penetre en el enmarcado si se colocan los tornillos en la
parte inferior del plénum. Consulte el Detalle A.
Aplique sellador sobre la parte inferior del plénum en la
unión entre la pieza A y la pieza B, aplicando el sellador 3
pulgadas sobre cada lado.
Sellador Adecuado*
Sobre los 4 laterales
A
A
A
A
Detalle A
Cuatro lugares
Tornillos*

Transcripción de documentos

Installation Instructions for your new RAVWPT15 Wall Plenum Before you begin - Read these instructions completely and carefully. IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer – Be sure to leave these instructions with the end user. Note to end user – Keep these instructions with your Owner’s Manual for future reference. YOUR WALL PLENUM WILL ONLY WORK IF INSTALLED CORRECTLY. MAKE SURE TO INSTALL THE WALL PLENUM IN THE CORRECT ORIENTATION AS SHOWN IN THE ILLUSTRATIONS. For easier installation, Grille Kit RAVAL3 should be installed at time of Wall Plenum Installation. Parts Included There are two parts to a Wall Plenum: Part A - Outside Plenum Installed so the large opening is on the bottom and the drain holes and keyhole slots for attaching the grille are on the outside of the building. Part B - Inside Plenum Installed so the large opening is on the bottom and the top and side flanges are against the inside wall of the building. Part B Inside Wall Plenum Large opening Materials Needed (Field Supplied Parts) Large opening • • • • • Exterior silicone caulk (recommended) Flashing Shims Header Material/Wall Studs 1” - 3” Screws to attach the plenum assembly to the wall studs. • Grille Kit RAVAL3 (sold separately) Part A outside Wall Plenum Installation Overview Properly sized header is required for structural support. Proper caulking and flashing are required NOTE: The plenum has a wax cardboard weather cover. Do not remove this cover until ready to install the grille (RAVAL3) Part A Outside Wall Plenum Exterior/ Outside Wall Part B Inside Wall Plenum RAVDPLAT Unit GE is a trademark of the General Electric Company. Manufactured under trademark license. 31-5000506 Rev. 0 08-20 GEA Installation Instructions STEP 1 Outside Wall Plenum Opening Ensure the outside wall plenum opening is properly framed and square per the diagram shown below. IMPORTANT: The wall plenum is not designed to carry structural loads. A proper header must be built into the rough opening and a proper lintel must be installed to support brick or other masonry materials. The plenum requires flashing, shimming and caulking for a weatherresistant installation. 32” It is the responsibility of the contractor to properly install the plenum and meet building code requirements. 24” STEP 2 Setting the Plenum Depth Rear screws Measure the rough opening depth Building rough opening D Outside Wall Inside Wall Front screws If the rough opening depth is less than 7.5”, proceed to STEP 3. If the rough opening depth is more than 7.5”, remove and discard the front 2 screws on the plenum divider and loosen the rear 2 screws. This will allow Part A and Part B to slide apart. Adjust the plenum depth by sliding Part A and Part B apart. Set plenum 1/4” deeper than the rough opening to allow for a caulking edge on the exterior. D + 1/4” Tighten the rear screws. 2 Installation Instructions STEP 3 Install Grille Kit RAVAL3 (not included) on the Outside Plenum NOTE: The Grille Kit RAVAL3 is best installed onto the Outside Plenum (Part A) prior to the wall plenum being installed into the building. Grille installation is easier at this point and will help keep the wall plenum square during installation. If you are not installing the grille at this time be sure the plenum is square when installed in the opening and do not remove the weather cover. NOTE: Refer to instructions included in the Grille Kit RAVAL3 for proper installation procedure. Side View RAVAL3 Part A Outside Wall Plenum Proper Header* STEP 4 Plenum Installation Proper Caulking* Part A Outside Wall Plenum RAVAL3 Building rough opening Proper Flashing* NOTES: • A properly sized header and rough in framing must conform to all national and local building codes. • Before caulking and permanent attachment, dry fit plenum into the rough opening to check for fit, squareness and level. Caulk the wall plenum on the rough opening side of the wall plenum flange. Proper Caulking* Proper Header* Outside Wall Building rough opening Proper Flashing* Direction of installation * Field Supplied Parts Direction of installation 3 Installation Instructions STEP 4 Plenum Installation (cont.) Secure plenum using the field supplied screws through the four provided slots in the plenum front face. If additional screws are used to secure the inside of the wall plenum to the rough opening framing, only drive screws through the vertical sides of the wall plenum. Water may penetrate into framing if screws are driven into the bottom of the plenum. See Detail A. A A A Detail A Four places Apply caulk on the bottom of the plenum at the seam between part A and part B, running the caulk 3 inches up each side. A Screws* Caulk may need to be applied to the outside of the building along all top, bottom and sides of the plenum to ensure a water tight seal. Proper Caulking* All 4 sides * Field Supplied Parts Printed in China 4 Instructions d’installation pour votre nouveau plénum mural RAVWPT15 Avant de commencer – Lisez ces instructions attentivement et en entier. IMPORTANT – RESPECTEZ TOUS LES CODES ET RÈGLEMENTS APPLICABLES. Remarque à l’intention de l’installateur – Assurez-vous de remettre ces instructions au utilisateur final. Note à l’utilisateur final - Conservez ces instructions avec le manuel du propriétaire afin de pouvoir vous y reporter ultérieurement. LE PLÉNUM MURAL FONCTIONNERA UNIQUEMENT S’IL EST INSTALLÉ CORRECTEMENT. GRILLE AVEC 4 VIS DE MONTAGE INSTALLÉES EN USINE. Pour faciliter l’installation, l’ensemble de grille RAVAL3 doit être installé au moment de l’installation du plénum mural. Liste des pièces Un plénum mural comprend deux parties : Partie A – Plénum extérieur Installez de manière à ce que la grande ouverture se retrouve au bas et que les trous de drainage et les fentes piriformes fixant la grille se retrouvent à l’extérieur du bâtiment. Partie B – Plénum intérieur Installé de manière à ce que la grande ouverture soit au bas et que la partie supérieure et les collerettes d’encastrement se trouvent contre le mur intérieur du bâtiment. Partie B du plénum mural intérieur Grande ouverture Grande ouverture Matériel requis (pièces sur le terrain) • • • • • • Matériau d’étanchéité au silicone (recommandé) Solin Entretoises Matériau de linteau/poteau de cloison Vis de 1 po – 3 po pour fixer le plénum aux poteaux de cloison. Ensemble de grille RAVAL3 (vendu séparément) Partie A du plénum mural extérieur Aperçu de l’installation Un linteau de taille adéquate est requis pour le soutien structural. La Properly pose d’unsized solinheader et d’unis required structural matériau for d’étanchéité support. est Proper caulking adéquat requise. and flashing are required REMARQUE: le plénum NOTE: The has a dispose d’unplenum capot protecteur wax cardboard weather en carton ciré. Ne retirez pas cover. Do notjusqu’à removece que ce couvercle this cover vous soyezuntil prêtready à installer la to install the grille (Ens. n°grille RAVAL3). (RAVAL3) Partie A Plénum mural Part A Outside extérieur Wall Plenum Extérieur/ Mur extérieur Exterior/ Outside Wall Partie B Plénum mural Part B Inside intérieur Wall Plenum RAVDPLAT Appareil Unit GE est une marque de commerce de General Electric Company. Fabriqué sous licence d’utilisation de marque. 31-5000506 Rev. 0 08-20 GEA Instructions d’installation ÉTAPE 1 Ouverture de plénum de mur extérieur Assurez-vous que la structure de l’ouverture de plénum de mur extérieur est adéquate et à l’équerre, comme montré dans le schéma ci-dessous. IMPORTANT: Le plénum de mur n’est pas conçu pour supporter une charge structurelle. Un chevêtre adéquat doit être construit dans l’ouverture brute et un linteau doit être installé pour supporter la brique ou les autres matériaux de maçonnerie. Le plénum requiert un solin, un calage et un calfeutrant pour étanchéiser l’installation. 32” L’entrepreneur est responsable d’installer correctement le plénum en conformité avec les exigences du code du bâtiment. 24” ÉTAPE 2 Ajustement de la profondeur du plénum Vis arrière Mesurez la profondeur brute de l’ouverture Ouverture brute dans le bâtiment D Mur intérieur Mur extérieur Vis frontales Si la profondeur brute de l’ouverture est inférieure à 19 cm (7,5 po), passez à l’ÉTAPE 3. Si la profondeur brute de l’ouverture est supérieure à 19 cm (7,5 po), retirez et jetez les deux vis frontales du diviseur de plénum et dévissez les 2 vis arrière. Ceci permettra de faire glisser et séparer les parties A et B. Ajustez la profondeur du plénum en faisant glisser et séparer les parties A et B. Placez le plénum sur 0,6 cm (1/4 po) plus profond que l’ouverture brute pour permettre le calfeutrage à l’extérieur. D + 1/4” Serrez les vis arrière. 2 Instructions d’installation ÉTAPE 3 Installer l’ensemble de grille RAVAL3 (non compris) sur le plénum extérieur REMARQUE: il est préférable d’installer l’ensemble de grille RAVAL3 sur le plénum extérieur (Partie A) avant d’installer le plénum mural sur le bâtiment. L’installation de la grille est plus facile à ce moment et cela aidera à garder le plénum mural à l’équerre pendant l’installation. Vue latérale Si vous n’installez pas la grille à ce moment, assurez-vous que le plénum est à l’équerre lorsqu’il est inséré dans l’ouverture et ne retirez pas le couvercle . REMARQUE : reportez-vous aux instructions comprises dans l’ensemble de grille RAVAL3 pour connaître la procédure d’installation adéquate. RAVAL3 Part A Outside Wall Plenum ÉTAPE 4 Installation du plénum REMARQUES: • Le linteau et l’ossature hors toute de dimensions Linteau adéquat* Calfeutrement adéquat* Solin adéquat* Part A Outside Wall Plenum RAVAL3 Ouverture brute dans le bâtiment adéquates doivent être conformes aux codes du bâtiment locaux et nationaux. • Avant la pose du matériau d’étanchéité et la mise en place permanente, ajustez à sec le plénum extérieur dans l’ouverture brute et vérifiez l’ajustement, la mise à l’équerre et la mise au Linteau adéquat* Calfeutrement adéquat* niveau. Appliquez un calfeutrant sur le plénum mural sur la partie brute de l’ouverture de la collerette d’encastrement du plénum mural. Mur extérieur Ouverture brute dans le bâtiment Solin adéquat* Instruction d’installation * Pièce fournie sur le terrain Instruction d’installation 3 Instructions d’installation ÉTAPE 4 Installation du plénum (suite) Fixez fermement le plénum à l’aide des vis fournies sur place en les insérant dans les quatre fentes prévues sur la face du plénum. Si vous devez utiliser d’autres vis pour fixer fermement l’intérieur du plénum mural à l’ouverture brute de la structure, ne les insérer que sur les côtés verticaux du plénum mural. L’eau peut pénétrer dans la structure si les vis sont insérées au bas du plénum. Consultez le Détail A. A A A Détails A Quatre endroits Appliquez le calfeutrant au bas du plénum, au joint situé entre les parties A et B et en l’appliquant sur 7,6 cm (3 po) vers le haut, de chaque côté. A Vis L’application d’un calfeutrant peut être nécessaire à l’extérieur du bâtiment sur tout le pourtour du plénum afin d’assurer son étanchéité. Calfeutrant adéquat* sur les 4 côtés * Pièce fournie sur le terrain Imprimé aux China 4 Instrucciones de Instalación de su nuevo Plénum de Pared RAVWPT15 Antes de comenzar – Lea estas instrucciones completamente y de forma detenida. IMPORTANTE - CUMPLA CON TODOS LOS CÓDIGOS Y ORDENANZAS GUBERNAMENTALES. Nota para el Instalador – Asegúrese de entregarle estas instrucciones al usuario final. Nota para el usuario final – Guarde estas instrucciones con su Manual del Usuario para referencia futura. SU PLÉNUM DE PARED SÓLO FUNCIONARÁ SI ES INSTALADO DE FORMA CORRECTA. ASEGÚRESE DE INSTALAR EL PLÉNUM DE PARED EN LA ORIENTACIÓN CORRECTA COMO SE MUESTRA EN LAS ILUSTRACIONES. A fin de facilitar la instalación, el Kit de Rejilla RAVAL3 deberá ser instalado en el momento en que se instale el Plénum de Pared. Piezas Incluidas Los Plénum de Pared cuentan con dos piezas: Pieza A—Plénum Externo Instalado de forma que la apertura grande esté en la parte inferior y que los agujeros de drenaje y las ranuras con forma de cerradura para adherir la rejilla estén en la parte exterior de la edificación. Pieza B – El Plénum Interno Instalado de forma que la apertura grande esté en la parte inferior y que las bridas superiores y laterales queden contra la pared interior de la edificación. Pieza B dentro del Plénum de Pared Abertura Grande Materiales Necesarios (Piezas Específicas Suministradas) Abertura Grande • • • • • Sellador de Silicona (recomendado) Plancha Cuñas Material de la Viga/ Montajes de Pared Tornillos de 1” a 3” para adherir el ensamble del plénum a los montajes de pared. • Kit de Rejilla RAVAL3 (se vende aparte) Pieza A afuera del Plénum de Pared Descripción General de la Instalación Se requiere una viga del tamaño adecuado para el Properly sized header is soporte de la estructura. required for structural Se requiere una caulking lámina y support. Proper sellador adecuados. and flashing are required NOTA: El plénum cuenta NOTE: The plenum has a con un protector de cartón wax cardboard weather encerado. No retire este cover. Dohasta not remove protector que esté this cover para until ready preparado instalar la to install the grille rejilla (Kit nº RAVAL3). (RAVAL3) Pieza A Part Ade Outside Plénum la Pared Externa Wall Plenum Exterior/ Pared Exterior/ Externa Outside Wall Pieza PartBB Inside Plénum de la Wall Plenum Pared Interna Unidad RAVDPLAT Unit GE Appliances es una marca registrada de la Empresa General Electric. Fabricado bajo licencia de la marca registrada. 31-5000506 Rev. 0 08-20 GEA Instrucciones de Instalación PASO 1 Pieza A afuera del Plénum de Pared Asegúrese de que la abertura exterior del plénum de pared esté correctamente enmarcada y en ángulo recto de acuerdo con el diagrama que figura a continuación. IMPORTANTE: El plénum de pared no fue diseñado para transportar cargas estructurales. Se deberá construir una viga adecuada en la abertura rústica y se deberá instalar un dintel apropiado que soporte ladrillos u otros materiales de mampostería. El plénum requiere una plancha, cuñas y sellador para una instalación resistente al clima. 32” Es responsabilidad del contratista instalar de forma correcta el plénum y cumplir con los requisitos del código de construcción. 24” PASO 2 Configuración de la Profundidad del Plénum Tornillos traseros Mida la profundidad de la abertura rústica Abertura de la Pared del Edificio D Pared interna Pared Externa Tornillos frontales Si la profundidad de la abertura rústica es inferior a 7.5”, proceda al PASO 3. Si la profundidad de la abertura rústica es superior a 7.5”, retire los 2 tornillos frontales del divisor del plénum y afloje los 2 tornillos traseros. Esto permitirá que la Pieza A y la Pieza B se deslicen. Ajuste la profundidad del plénum mientras aleja la Pieza A y la Pieza B deslizándolas. Configure el plénum a una profundidad de ¼” mayor que aquella de la apertura rústica, a fin de poder contar con un extremo sellado en el exterior. D + 1/4” Ajuste los tornillos traseros. 2 Instrucciones de Instalación PASO 3 Instale el Kit de Rejilla RAVAL3 (no incluido) en el Plénum Externo NOTA: La instalación del Kit de Rejilla RAVAL3 es más conveniente en el Plénum Externo (Pieza A), antes de la instalación del plénum de pared en el edificio. La instalación de la rejilla es más fácil en este punto, y ayudará a mantener el plénum de pared, el cual se cuadró durante la instalación. Vista Lateral Si no instalará la rejilla en esta oportunidad, asegúrese de que el plénum quede cuadrado durante su instalación en la abertura y no retire la tapa de la entrada de clima. NOTA: Para conocer los procedimientos adecuados de instalación, consulte las instrucciones incluidas en el Kit de Rejilla RAVAL3. RAVAL3 Part A Outside Wall Plenum PASO 4 Instalación del Plénum: NOTAS Viga Adecuada* Sellador Adecuado* Plancha Adecuada* Part A Outside Wall Plenum RAVAL3 Abertura de la Pared del Edificio • Una viga y una abertura del tamaño correctos en el marco deberán cumplir con todos los códigos de edificación nacionales y locales. • Antes de la aplicación del sellador y de la adhesión permanente, seque la parte externa del plénum en la abertura de la pared y controle el ajuste, encuadre y que Viga Adecuada* el plénum esté nivelado. Sellador Adecuado* Selle el plénum de pared sobre el lado de la abertura rústica de la brida del plénum de pared. Abertura de la Pared del Edificio Pared Externa Plancha Adecuada* Dirección de la instalación * Piezas Específicas Suministradas Dirección de la instalación 3 Instrucciones de Instalación PASO 4 Instalación del Plénum: (cont.) Asegure el plénum insertando los tornillos suministrados a través de las cuatro ranuras provistas sobre la cara frontal del plénum. Si se usan tornillos adicionales para asegurar la parte interior del plénum de pared sobre el marco de la abertura rústica, sólo coloque los tornillos a través de los laterales verticales del plénum de pared. Es posible que el agua penetre en el enmarcado si se colocan los tornillos en la parte inferior del plénum. Consulte el Detalle A. A A A Detalle A Cuatro lugares Tornillos* Aplique sellador sobre la parte inferior del plénum en la unión entre la pieza A y la pieza B, aplicando el sellador 3 pulgadas sobre cada lado. A Es posible que sea necesario aplicar sellador en la parte exterior de la edificación, a lo largo del lado superior, inferior y laterales del plénum, a fin de asegurar un sellado hermético del agua. Sellador Adecuado* Sobre los 4 laterales * Piezas Específicas Suministradas Impreso en China 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

GE RAVWPT15B Guía de instalación

Tipo
Guía de instalación
Este manual también es adecuado para