GE RAVTRANS2 Guía de instalación

Tipo
Guía de instalación
31-5000568 Rev. 0 11-20 GEA
RAVTRANS2 will fit the following GE Appliances Plenum Kits: RAVWP6, RAVWP8, RAVWP12 and
RAVWP15. Remove any black transition plenum already installed.
Installation Instructions
for your new
RAVTRANS2
Transition Plenum
For replacing AZ75, AZ85 series units with a 6”, 8”,
12“ or 15” plenums.
For replacing AZ90 and AZ91 series units installed
with black RAVTRANS transition plenum to 6”, 8”,
12” or 15” fixed length tan plenums.
Before you begin - Read these instructions completely and carefully.
IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions with your Owner’s Manual for future reference.
RAVTRANS2 kit is required when replacing existing AZ75, AZ85, AZ90 or AZ91 series vertical air conditioner
with a new AZ95 series vertical air conditioner when the existing wall plenum is a 6”, 8”, 12” or 15” fixed
length tan color wall plenum. Changes in drain exit locations and drain routing, electrical connections,
platform height, conditioned air duct locations and additional space requirements for installation of
RAVTRANS2 kit are all items that need to be considered when replacing AZ75, AZ85, AZ90 or AZ91 series
units with an AZ95 series unit.
Installation of a new AZ95 series unit with a transition plenum will take up approximately 1 1/2” of additional
closet space once the unit is fully installed. Before starting the conversion be sure there is adequate closet
space to meet the manufacture’s recommend minimum clearance requirements.
Parts Included
• Transition Plenum
• 12 - #10 ¾” long 5/16” hex head sheet metal screws
• Front Bracket
Installation Overview
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Plenum
Front Bracket
Mounting
Locations
Existing Architectural
Louver*
Exterior/
Outside Wall
Existing
Wall Plenum*
RAVTRANS2
Included in
RAVTRANS2
RAVDPLAT*
UNIT*
*Sold Separately
2
Installation Instructions
STEP 1:
Prepare Installation Area by Removing the Existing Unit and RAVTRANS plenum
(if applicable)
WARNING
5LVNRI(OHFWULFDO6KRFNFDQFDXVHLQMXU\RUGHDWK%HIRUHVHUYLFLQJVZLWFKSRZHURႇDW
the service panel and lock the area to prevent power from being switched on accidentally.
To remove the AZ75/AZ85 series unit:
1. Disconnect the power coming into the unit from the main breaker or
closet mounted disconnect.
2. Remove the front case panel (for front install) or front and side case
panel (for side install).
3. Unplug the 9-pin yellow connector and disconnect the wall thermostat
connection.
4. Fully loosen the 4 adjustable screws on the top cover and disconnect
the top duct work from the unit.
5. Remove the front and or side case-to-unit grounding screws, if
present.
6. Slide the unit out of the case.
7. Disconnect all of the drains.
8. Remove the bolts holding the case to the platform (if present).
9. Remove the 6 screws securing the case to the plenum.
10. Remove the case.
11. Remove any existing platform.
To remove AZ90/91 series unit:
1. Disconnect the power coming into the unit from the main breaker or closet mounted disconnect.
2. Remove power disconnect on front of the unit.
3. Remove front panel.
4. Disconnect power wires from the unit.
5. Disconnect thermostat wires from the unit.
6. Disconnect all of the drains.
7. Disconnect air duct on top of the unit.
8. Remove the unit.
9. Remove any existing platform.
10. Remove the black RAVTRANS transition plenum.
STEP 2:
Install and Connect the Transition Plenum to the Existing Wall Plenum
3ODFHWKHWUDQVLWLRQSOHQXPLQIURQWRIWKHH[LVWLQJZDOOSOHQXPZLWKWKHÀDQJHVLGHIDFLQJDZD\IURPWKHZDOOSOHQXP
2. Align the transition plenum mounting holes to the mounting holes on the existing wall plenum. The top of the
WUDQVLWLRQSOHQXPVKHHWPHWDOVKRXOGEHÀXVKZLWKWKHWRSRIWKHH[LVWLQJSOHQXP
3. Attach the transition plenum to the wall plenum with the 6 supplied screws.
Inside
Wall
Rigid
Ductwork
Access
Panel or
Closet Door
Existing
Wall Plenum
When complete the closet area
should look like this.
Mounting
Locations
Rigid
Ductwork
Flush with
top of
existing
wall plenum
Flange
Align Mounting Locations
3
Installation Instructions
STEP 3:
Attach the Front Bracket to the Plenum
1. Align the front bracket with the plenum.
2. Fasten the front bracket to the plenum with the 6 screws provided.
4
Notes
Printed in the United States
Instructions d’installation pour le
nouveau
RAVTRANS2
Plénum de transition
Pour remplacer les unités des séries AZ75 et AZ85 par
des plénums 6, 8, 12 ou 15 po.
Pour remplacer les unités des séries AZ90 et AZ91
installées avec le plénum de transition noir RAVTRANS par
des plénums brun clair (tan) de longueur 6, 8, 12 ou 15 po.
Avant de commencer - Veuillez lire ces instructions attentivement et en totalité.
IMPORTANT – OBSERVEZ TOUS LES CODES ET RÈGLEMENTS EN VIGUEUR.
Note à l’installateur – Assurez-vous de laisser ces instructions au consommateur.
Note au consommateur - Conservez ces instructions avec votre manuel d’utilisation pour consultation ultérieure.
31-5000568 Rev. 0 11-20 GEA
Le plénum RAVTRANS2 est compatible avec les trousses de plénum GE Appliances suivantes : RAVWP6, RAVWP8,
RAVWP12 et RAVWP15. Retirez tout plénum de transition noir déjà installé.
La trousse RAVTRANS2 est nécessaire pour remplacer un climatiseur vertical existant de série AZ75, AZ85, AZ90 ou
AZ91 par un nouveau climatiseur vertical de série AZ95 lorsque le plénum mural existant est de couleur brun clair (tan)
de longueur fixe de 6, 8, 12 ou 15 po. L’installation de la trousse RAVTRANS2 lors du remplacement des unités de série
AZ75, AZ85, AZ90 ou AZ91 par une unité de série AZ95 exige de considérer les modifications suivantes : trajectoire du
tuyau d’évacuation, position de la sortie d’évacuation, connexions électriques, hauteur de la plateforme, emplacement
des conduits d’air climatisé, augmentation des dégagements.
L’installation d’une nouvelle unité de série AZ95 par un plénum de transition nécessite que l’armoire soit agrandie
d’environ 1 1/2 po une fois l’unité complètement installée. Avant de commencer la conversion, assurez-vous que l’armoire
est suffisamment grande pour satisfaire les recommandations du fabricant relatives aux dégagements minimaux.
Aperçu de l’installation
GE est une marque de commerce de General Electric Company. Fabriqué sous licence de marque.
Évent à lames
architectural existant*
Mur extérieur
Plénum mural
existant*
RAVTRANS2
Inclus avec l’unité
RAVTRANS2*
RAVDPLAT*
UNIT*
*Vendus séparément
Pièces incluses
• Plénum de transition
• Vis à tôle 12 - #10 de 3/4 po de long et tête hexagonale 5/16 po
• Support frontal
Plenum
Front Bracket
Mounting
Locations
Plénum
Support avant
Points de
montage
2
Instructions d’installation
ÉTAPE 1 :
Préparer la zone d’installation en retirant l’unité existante et le plénum RAVTRANS
(s’il y a lieu)
AVERTISSEMENT
Risque de choc électrique pouvant causer une blessure ou la mort. Avant de procéder à
XQHUpSDUDWLRQRXXQHQWUHWLHQFRXSH]OHFRXUDQWDXSDQQHDXGHVHUYLFHHWYHUURXLOOH]OD]RQHD¿QGHSUpYHQLUOH
rétablissement accidentel du courant.
Pour retirer une unité de série AZ75/AZ85 :
1. Coupez le courant qui arrive dans l’unité depuis le disjoncteur principal ou
l’interrupteur monté dans l’armoire.
2. Retirez le panneau frontal de l’enceinte (pour une installation frontale) ou le
panneau frontal ou latéral (pour une installation latérale).
3. Débranchez le connecteur jaune à 9 broches ainsi que la connexion du
thermostat mural.
4. Desserrez complètement les 4 vis de réglage sur le couvercle du haut et
déconnectez le conduit du haut de l’unité.
5. Retirez les vis de terre « enceinte à unité » avant et/ou latérale, si présentes.
6. Glissez l’unité à l’extérieur de l’enceinte.
7. Déconnectez tous les tuyaux d’évacuation.
5HWLUH]OHVERXORQVTXL¿[HQWO¶HQFHLQWHVXUODSODWHIRUPHVLSUpVHQWH
5HWLUHUOHVYLVTXL¿[HQWO¶HQFHLQWHVXUOHSOpQXP
10. Retirez l’enceinte.
11. Retirez toute plateforme existante.
Pour retirer une unité de série AZ90/91 :
1. Coupez le courant qui arrive dans l’unité depuis le disjoncteur principal ou l’interrupteur monté dans l’armoire.
2. Retirez l’interrupteur de courant sur le devant de l’unité.
3. Retirez le panneau frontal.
4. Déconnectez les câbles d’alimentation électrique de l’unité.
'pFRQQHFWH]OHV¿OVGXWKHUPRVWDWGHO¶XQLWp
6. Déconnectez tous les tuyaux d’évacuation.
7. Déconnectez le conduit d’air dans le haut de l’unité.
8. Retirez l’unité.
9. Retirez toute plateforme existante.
10. Retirez le plénum de transition noir RAVTRANS.
ÉTAPE 2 :
Installer et connecter le plénum de transition sur le plénum mural existant
1. Placez le plénum de transition devant le plénum mural existant, côté collet dans la direction opposée au plénum mural.
2. Alignez les trous de montage du plénum de transition sur les trous de montage du plénum mural existant. Le dessus de la tôle du
plénum de transition doit être à égalité avec le dessus du plénum existant.
3. Fixez le plénum de transition sur le plénum mural à l’aide des 6 vis fournies.
Inside
Wall
Rigid
Ductwork
Access
Panel or
Closet Door
Existing
Wall Plenum
When complete the closet area
should look like this.
Mounting
Locations
Rigid
Ductwork
Flush with
top of
existing
wall plenum
Flange
Points de montage facultatifs
Mur
intérieur
Panneau
d’accès ou
porte d’ar-
moire
Plénum mural
existant
Conduit
rigide
Une fois terminé, la zone de l’armoire
devrait ressembler à ceci.
Points de
montage
Conduit
rigide
Collet
À égalité avec le
dessus du plénum
mural existant
3
Instructions d’installation
ÉTAPE 3:
Fixer le support frontal sur le plénum
1. Alignez le support frontal sur le plénum.
2. Fixez le support frontal sur le plénum à l’aide des 6 vis fournies.
4
Notes
Imprimé aux États-Unis
Instrucciones de Instalación
para su nuevo
RAVTRANS2
Plénum de Transición
Para reemplazar las unidades de las series AZ75, AZ85 por un
plénum de 6”, 8”, 12“ o 15”.
Para reemplazar las unidades de las series AZ90 y AZ91
instaladas con el plénum de transición RAVTRANS con plénums
de color tostado de longitudes fijas de 6”, 8”, 12” o 15”.
Antes de comenzar – lea estas instrucciones completamente y de forma detenida.
IMPORTANTE- CUMPLA CON TODOS LOS CÓDIGOS Y ORDENANZAS GUBERNAMENTALES.
Nota para el Instalador – Asegúrese de entregar estas instrucciones al Consumidor.
Nota para el Consumidor – Guarde estas instrucciones con su Manual del Propietario para referencia futura.
31-5000568 Rev. 0 11-20 GEA
El Kit RAVTRANS2 se adaptará a los siguientes kits de plénum de GE Appliances: RAVWP6, RAVWP8, RAVWP12 y
RAVWP15. Retire cualquier plénum de transición negro ya instalado.
Se requiere el kit RAVTRANS2 al reemplazar los acondicionadores de aire verticales AZ75, AZ85, AZ90 o AZ91 por un
acondicionador de aire vertical de la serie AZ95, cuando el plénum de pared existente sea un plénum de pared de color
tostado de longitud fija de 6”, 8”, 12” o 15”. Los cambios en las ubicaciones de salida del drenaje y del recorrido del
drenaje, conexiones eléctricas, altura de la plataforma, ubicaciones de los conductos de acondicionadores de aire y
requisitos de espacio adicionales para la instalación del kit RAVTRANS son todos ítems que deberán ser tenidos en
consideración al reemplazar unidades de las series AZ75, AZ85, AZ90 o AZ91 por una unidad de la serie AZ95.
La instalación de una nueva unidad de la serie AZ95 con un plénum de transición tomará aproximadamente 1 ½” de
espacio adicional del armario una vez que la unidad esté completamente instalada. Antes de iniciar la conversión,
asegúrese de que haya un espacio adecuado en el armario para cubrir los requisitos de espacio libre mínimos
recomendados por el fabricante.
Piezas Incluidas
• Plénum de Transición
12 – tornillos metálicos nº 10 y longitud de ¾” para chapa con
cabeza hexagonal de 5/16”
• Soporte Frontal
Información General de la Instalación
GE Appliances es una marca de General Electric Company. Fabricado bajo licencia de la marca.
Plenum
Front Bracket
Mounting
Locations
Persiana Arquitectónica
Existente*
Exterior/ Pared
Externa
Plénum de Pared
Existente*
RAVTRANS2
Incluido en
RAVTRANS2
RAVDPLAT*
Unidad*
*Se Adquiere por Separado
Ubicaciones
de Montaje
Plénum
Soporte
delantero
2
Instrucciones de Instalación
PASO 1:
Prepare el Área de Instalación Retirando la Unidad Existente y el Plénum RAVTRANS
(si corresponde)
WARNING
Existe riesgo de descargas eléctricas que pueden ocasionar lesiones o la muerte. Antes de
FRPHQ]DUFRQODUHSDUDFLyQDSDJXHHOLQWHUUXSWRUGHOSDQHOGHOVHUYLFLR\EORTXHHHOiUHDD¿QGHHYLWDUTXHODFRUULHQWHVH
active de forma accidental.
Para retirar la unidad de las series AZ75/AZ85:
1. Desconecte la corriente que ingresa a la unidad desde el panel del disyuntor
principal o desde la desconexión montada en el armario.
2. Retire el panel de la carcasa frontal (para la instalación frontal) o el panel de
la carcasa frontal y lateral (para la instalación lateral).
3. Desenchufe el conector amarillo de 9 clavijas y quite la conexión del
termostato de pared.
$ÀRMHFRPSOHWDPHQWHORVWRUQLOORVDMXVWDEOHVHQODWDSDVXSHULRU\
desconecte el conducto superior de la unidad.
5. Retire los tornillos de tierra del frente y/o lateral del gabinete a la unidad, de
estar presentes.
6. Deslice la unidad fuera del gabinete.
7. Desconecte todo el drenaje.
8. Retire los tornillos que sostienen el gabinete sobre la plataforma (de estar
presentes).
9. Retire los 6 tornillos que aseguran el gabinete al plénum.
10. Retire el gabinete.
11. Retire cualquier plataforma existente.
Para retirar la unidades de las series AZ91/91:
1. Desconecte la corriente que ingresa a la unidad desde el panel del disyuntor principal o desde la desconexión montada en el armario.
2. Retire la desconexión de corriente del frente de la unidad.
3. Retire el panel frontal.
4. Desconecte los cables de corriente de la unidad.
5. Desconecte los cables del termostato de la unidad.
6. Desconecte todo el drenaje.
7. Desconecte el conducto de aire que se encuentra sobre la unidad.
8. Retire la unidad.
9. Retire cualquier plataforma existente.
10. Retire el plénum de transición RAVTRANS negro.
PASO 2:
Instale y Conecte el Plénum de Transición al Plénum de Pared Existente
1. Coloque el plénum de transición frente al plénum de pared existente con el lado de la brida hacia afuera de la pared del plénum.
2. Alinee los agujeros de montaje del plénum de transición a los agujeros de montaje sobre el plénum de pared existente. La parte
superior del metal de la chapa del plénum de transición deberá estar nivelada con la parte superior del plénum existente.
3. Adhiera el plénum de transición al plénum de pared con los 6 tornillos suministrados.
Inside
Wall
Rigid
Ductwork
Access
Panel or
Closet Door
Existing
Wall Plenum
When complete the closet area
should look like this.
Mounting
Locations
Rigid
Ductwork
Flush with
top of
existing
wall plenum
Flange
Alinee las Ubicaciones del Montaje
Pared
Interior
Panel de
Acceso o
Puerta del
Armario
Plénum de
Pared Existente
Conducto
Rígido
Una vez completado, el área del
armario deberá verse así.
Ubicaciones
de Montaje
Conducto
Rígido
Brida
Al ras con la parte
superior del plé-
num existente
3
Instrucciones de Instalación
PASO 3:
Adhiera el Soporte Frontal al Plénum
1. Alinee el soporte frontal con el plénum.
2. Ajuste el soporte frontal al plénum con los 6 tornillos provistos.
4
Impreso en Estados Unidos
Notas

Transcripción de documentos

Installation Instructions for your new RAVTRANS2 Transition Plenum For replacing AZ75, AZ85 series units with a 6”, 8”, 12“ or 15” plenums. For replacing AZ90 and AZ91 series units installed with black RAVTRANS transition plenum to 6”, 8”, 12” or 15” fixed length tan plenums. Before you begin - Read these instructions completely and carefully. IMPORTANT – OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer – Be sure to leave these instructions with the Consumer. Note to Consumer – Keep these instructions with your Owner’s Manual for future reference. RAVTRANS2 will fit the following GE Appliances Plenum Kits: RAVWP6, RAVWP8, RAVWP12 and RAVWP15. Remove any black transition plenum already installed. RAVTRANS2 kit is required when replacing existing AZ75, AZ85, AZ90 or AZ91 series vertical air conditioner with a new AZ95 series vertical air conditioner when the existing wall plenum is a 6”, 8”, 12” or 15” fixed length tan color wall plenum. Changes in drain exit locations and drain routing, electrical connections, platform height, conditioned air duct locations and additional space requirements for installation of RAVTRANS2 kit are all items that need to be considered when replacing AZ75, AZ85, AZ90 or AZ91 series units with an AZ95 series unit. Installation of a new AZ95 series unit with a transition plenum will take up approximately 1 1/2” of additional closet space once the unit is fully installed. Before starting the conversion be sure there is adequate closet space to meet the manufacture’s recommend minimum clearance requirements. Parts Included Plenum • Transition Plenum • 12 - #10 ¾” long 5/16” hex head sheet metal screws • Front Bracket Mounting Locations Front Bracket Existing Architectural Louver* Installation Overview Included in RAVTRANS2 Exterior/ Outside Wall Existing Wall Plenum* RAVTRANS2 UNIT* RAVDPLAT* GE is a trademark of the General Electric Company. Manufactured under trademark license. *Sold Separately 31-5000568 Rev. 0 11-20 GEA Installation Instructions STEP 1: Prepare Installation Area by Removing the Existing Unit and RAVTRANS plenum (if applicable) WARNING 5LVNRI(OHFWULFDO6KRFNFDQFDXVHLQMXU\RUGHDWK%HIRUHVHUYLFLQJVZLWFKSRZHURႇDW the service panel and lock the area to prevent power from being switched on accidentally. To remove the AZ75/AZ85 series unit: 1. Disconnect the power coming into the unit from the main breaker or Inside Rigid closet mounted disconnect. Wall Ductwork 2. Remove the front case panel (for front install) or front and side case panel (for side install). 3. Unplug the 9-pin yellow connector and disconnect the wall thermostat Access Existing connection. Panel or Wall Plenum 4. Fully loosen the 4 adjustable screws on the top cover and disconnect Closet Door the top duct work from the unit. 5. Remove the front and or side case-to-unit grounding screws, if present. 6. Slide the unit out of the case. 7. Disconnect all of the drains. 8. Remove the bolts holding the case to the platform (if present). When complete the closet area 9. Remove the 6 screws securing the case to the plenum. should look like this. 10. Remove the case. 11. Remove any existing platform. To remove AZ90/91 series unit: 1. Disconnect the power coming into the unit from the main breaker or closet mounted disconnect. 2. Remove power disconnect on front of the unit. 3. Remove front panel. 4. Disconnect power wires from the unit. 5. Disconnect thermostat wires from the unit. 6. Disconnect all of the drains. 7. Disconnect air duct on top of the unit. 8. Remove the unit. 9. Remove any existing platform. 10. Remove the black RAVTRANS transition plenum. STEP 2: Install and Connect the Transition Plenum to the Existing Wall Plenum 3ODFHWKHWUDQVLWLRQSOHQXPLQIURQWRIWKHH[LVWLQJZDOOSOHQXPZLWKWKHÀDQJHVLGHIDFLQJDZD\IURPWKHZDOOSOHQXP 2. Align the transition plenum mounting holes to the mounting holes on the existing wall plenum. The top of the WUDQVLWLRQSOHQXPVKHHWPHWDOVKRXOGEHÀXVKZLWKWKHWRSRIWKHH[LVWLQJSOHQXP 3. Attach the transition plenum to the wall plenum with the 6 supplied screws. Rigid Ductwork Flush with top of existing wall plenum Mounting Locations Flange Align Mounting Locations 2 Installation Instructions STEP 3: Attach the Front Bracket to the Plenum 1. Align the front bracket with the plenum. 2. Fasten the front bracket to the plenum with the 6 screws provided. 3 Notes Printed in the United States 4 Instructions d’installation pour le nouveau RAVTRANS2 Plénum de transition Pour remplacer les unités des séries AZ75 et AZ85 par des plénums 6, 8, 12 ou 15 po. Pour remplacer les unités des séries AZ90 et AZ91 installées avec le plénum de transition noir RAVTRANS par des plénums brun clair (tan) de longueur 6, 8, 12 ou 15 po. Avant de commencer - Veuillez lire ces instructions attentivement et en totalité. IMPORTANT – OBSERVEZ TOUS LES CODES ET RÈGLEMENTS EN VIGUEUR. Note à l’installateur – Assurez-vous de laisser ces instructions au consommateur. Note au consommateur - Conservez ces instructions avec votre manuel d’utilisation pour consultation ultérieure. Le plénum RAVTRANS2 est compatible avec les trousses de plénum GE Appliances suivantes : RAVWP6, RAVWP8, RAVWP12 et RAVWP15. Retirez tout plénum de transition noir déjà installé. La trousse RAVTRANS2 est nécessaire pour remplacer un climatiseur vertical existant de série AZ75, AZ85, AZ90 ou AZ91 par un nouveau climatiseur vertical de série AZ95 lorsque le plénum mural existant est de couleur brun clair (tan) de longueur fixe de 6, 8, 12 ou 15 po. L’installation de la trousse RAVTRANS2 lors du remplacement des unités de série AZ75, AZ85, AZ90 ou AZ91 par une unité de série AZ95 exige de considérer les modifications suivantes : trajectoire du tuyau d’évacuation, position de la sortie d’évacuation, connexions électriques, hauteur de la plateforme, emplacement des conduits d’air climatisé, augmentation des dégagements. L’installation d’une nouvelle unité de série AZ95 par un plénum de transition nécessite que l’armoire soit agrandie d’environ 1 1/2 po une fois l’unité complètement installée. Avant de commencer la conversion, assurez-vous que l’armoire est suffisamment grande pour satisfaire les recommandations du fabricant relatives aux dégagements minimaux. Pièces incluses Plenum Plénum • Plénum de transition • Vis à tôle 12 - #10 de 3/4 po de long et tête hexagonale 5/16 po Mounting Points de Locations montage • Support frontal Support avant Front Bracket Évent à lames architectural existant* Aperçu de l’installation Inclus avec l’unité RAVTRANS2* Mur extérieur Plénum mural existant* RAVTRANS2 UNIT* RAVDPLAT* GE est une marque de commerce de General Electric Company. Fabriqué sous licence de marque. *Vendus séparément 31-5000568 Rev. 0 11-20 GEA Instructions d’installation ÉTAPE 1 : Préparer la zone d’installation en retirant l’unité existante et le plénum RAVTRANS (s’il y a lieu) AVERTISSEMENT Risque de choc électrique pouvant causer une blessure ou la mort. Avant de procéder à XQHUpSDUDWLRQRXXQHQWUHWLHQFRXSH]OHFRXUDQWDXSDQQHDXGHVHUYLFHHWYHUURXLOOH]OD]RQHD¿QGHSUpYHQLUOH rétablissement accidentel du courant. Pour retirer une unité de série AZ75/AZ85 : 1. Coupez le courant qui arrive dans l’unité depuis le disjoncteur principal ou l’interrupteur monté dans l’armoire. 2. Retirez le panneau frontal de l’enceinte (pour une installation frontale) ou le panneau frontal ou latéral (pour une installation latérale). 3. Débranchez le connecteur jaune à 9 broches ainsi que la connexion du thermostat mural. 4. Desserrez complètement les 4 vis de réglage sur le couvercle du haut et déconnectez le conduit du haut de l’unité. 5. Retirez les vis de terre « enceinte à unité » avant et/ou latérale, si présentes. 6. Glissez l’unité à l’extérieur de l’enceinte. 7. Déconnectez tous les tuyaux d’évacuation. 5HWLUH]OHVERXORQVTXL¿[HQWO¶HQFHLQWHVXUODSODWHIRUPH VLSUpVHQWH  5HWLUHUOHVYLVTXL¿[HQWO¶HQFHLQWHVXUOHSOpQXP 10. Retirez l’enceinte. 11. Retirez toute plateforme existante. Mur Inside intérieur Wall Rigid Conduit Ductwork rigide Access Panneau Panel or d’accès ou Closet Door porte d’armoire Plénum mural Existing existant Wall Plenum When the closet area Une foiscomplete terminé, la zone de l’armoire shouldressembler look like this. devrait à ceci. Pour retirer une unité de série AZ90/91 : 1. Coupez le courant qui arrive dans l’unité depuis le disjoncteur principal ou l’interrupteur monté dans l’armoire. 2. Retirez l’interrupteur de courant sur le devant de l’unité. 3. Retirez le panneau frontal. 4. Déconnectez les câbles d’alimentation électrique de l’unité. 'pFRQQHFWH]OHV¿OVGXWKHUPRVWDWGHO¶XQLWp 6. Déconnectez tous les tuyaux d’évacuation. 7. Déconnectez le conduit d’air dans le haut de l’unité. 8. Retirez l’unité. 9. Retirez toute plateforme existante. 10. Retirez le plénum de transition noir RAVTRANS. ÉTAPE 2 : Installer et connecter le plénum de transition sur le plénum mural existant 1. Placez le plénum de transition devant le plénum mural existant, côté collet dans la direction opposée au plénum mural. 2. Alignez les trous de montage du plénum de transition sur les trous de montage du plénum mural existant. Le dessus de la tôle du plénum de transition doit être à égalité avec le dessus du plénum existant. 3. Fixez le plénum de transition sur le plénum mural à l’aide des 6 vis fournies. Conduit rigide Rigid Ductwork Flushlewith À égalité avec top of dessus du plénum existing wall plenum mural existant Points de Mounting montage Locations Flange Collet Points de montage facultatifs 2 Instructions d’installation ÉTAPE 3: Fixer le support frontal sur le plénum 1. Alignez le support frontal sur le plénum. 2. Fixez le support frontal sur le plénum à l’aide des 6 vis fournies. 3 Notes Imprimé aux États-Unis 4 Instrucciones de Instalación para su nuevo RAVTRANS2 Plénum de Transición Para reemplazar las unidades de las series AZ75, AZ85 por un plénum de 6”, 8”, 12“ o 15”. Para reemplazar las unidades de las series AZ90 y AZ91 instaladas con el plénum de transición RAVTRANS con plénums de color tostado de longitudes fijas de 6”, 8”, 12” o 15”. Antes de comenzar – lea estas instrucciones completamente y de forma detenida. IMPORTANTE- CUMPLA CON TODOS LOS CÓDIGOS Y ORDENANZAS GUBERNAMENTALES. Nota para el Instalador – Asegúrese de entregar estas instrucciones al Consumidor. Nota para el Consumidor – Guarde estas instrucciones con su Manual del Propietario para referencia futura. El Kit RAVTRANS2 se adaptará a los siguientes kits de plénum de GE Appliances: RAVWP6, RAVWP8, RAVWP12 y RAVWP15. Retire cualquier plénum de transición negro ya instalado. Se requiere el kit RAVTRANS2 al reemplazar los acondicionadores de aire verticales AZ75, AZ85, AZ90 o AZ91 por un acondicionador de aire vertical de la serie AZ95, cuando el plénum de pared existente sea un plénum de pared de color tostado de longitud fija de 6”, 8”, 12” o 15”. Los cambios en las ubicaciones de salida del drenaje y del recorrido del drenaje, conexiones eléctricas, altura de la plataforma, ubicaciones de los conductos de acondicionadores de aire y requisitos de espacio adicionales para la instalación del kit RAVTRANS son todos ítems que deberán ser tenidos en consideración al reemplazar unidades de las series AZ75, AZ85, AZ90 o AZ91 por una unidad de la serie AZ95. La instalación de una nueva unidad de la serie AZ95 con un plénum de transición tomará aproximadamente 1 ½” de espacio adicional del armario una vez que la unidad esté completamente instalada. Antes de iniciar la conversión, asegúrese de que haya un espacio adecuado en el armario para cubrir los requisitos de espacio libre mínimos recomendados por el fabricante. Piezas Incluidas Plenum Plénum • Plénum de Transición • 12 – tornillos metálicos nº 10 y longitud de ¾” para chapa con cabeza hexagonal de 5/16” Mounting Ubicaciones deLocations Montaje • Soporte Frontal Soporte Front Bracket delantero Persiana Arquitectónica Existente* Información General de la Instalación Incluido en RAVTRANS2 Exterior/ Pared Externa Plénum de Pared Existente* RAVTRANS2 Unidad* RAVDPLAT* GE Appliances es una marca de General Electric Company. Fabricado bajo licencia de la marca. *Se Adquiere por Separado 31-5000568 Rev. 0 11-20 GEA Instrucciones de Instalación PASO 1: Prepare el Área de Instalación Retirando la Unidad Existente y el Plénum RAVTRANS (si corresponde) WARNING Existe riesgo de descargas eléctricas que pueden ocasionar lesiones o la muerte. Antes de FRPHQ]DUFRQODUHSDUDFLyQDSDJXHHOLQWHUUXSWRUGHOSDQHOGHOVHUYLFLR\EORTXHHHOiUHDD¿QGHHYLWDUTXHODFRUULHQWHVH active de forma accidental. Para retirar la unidad de las series AZ75/AZ85: 1. Desconecte la corriente que ingresa a la unidad desde el panel del disyuntor principal o desde la desconexión montada en el armario. 2. Retire el panel de la carcasa frontal (para la instalación frontal) o el panel de la carcasa frontal y lateral (para la instalación lateral). 3. Desenchufe el conector amarillo de 9 clavijas y quite la conexión del termostato de pared. $ÀRMHFRPSOHWDPHQWHORVWRUQLOORVDMXVWDEOHVHQODWDSDVXSHULRU\ desconecte el conducto superior de la unidad. 5. Retire los tornillos de tierra del frente y/o lateral del gabinete a la unidad, de estar presentes. 6. Deslice la unidad fuera del gabinete. 7. Desconecte todo el drenaje. 8. Retire los tornillos que sostienen el gabinete sobre la plataforma (de estar presentes). 9. Retire los 6 tornillos que aseguran el gabinete al plénum. 10. Retire el gabinete. 11. Retire cualquier plataforma existente. Pared Inside Interior Wall Rigid Conducto Ductwork Rígido Access Panel de Panel or Acceso o Closetdel Door Puerta Armario Plénum de Existing Pared Existente Wall Plenum When the elcloset area Una vezcomplete completado, área del should deberá look like this.así. armario verse Para retirar la unidades de las series AZ91/91: 1. Desconecte la corriente que ingresa a la unidad desde el panel del disyuntor principal o desde la desconexión montada en el armario. 2. Retire la desconexión de corriente del frente de la unidad. 3. Retire el panel frontal. 4. Desconecte los cables de corriente de la unidad. 5. Desconecte los cables del termostato de la unidad. 6. Desconecte todo el drenaje. 7. Desconecte el conducto de aire que se encuentra sobre la unidad. 8. Retire la unidad. 9. Retire cualquier plataforma existente. 10. Retire el plénum de transición RAVTRANS negro. PASO 2: Instale y Conecte el Plénum de Transición al Plénum de Pared Existente 1. Coloque el plénum de transición frente al plénum de pared existente con el lado de la brida hacia afuera de la pared del plénum. 2. Alinee los agujeros de montaje del plénum de transición a los agujeros de montaje sobre el plénum de pared existente. La parte superior del metal de la chapa del plénum de transición deberá estar nivelada con la parte superior del plénum existente. 3. Adhiera el plénum de transición al plénum de pared con los 6 tornillos suministrados. Conducto Rígido Rigid Ductwork with Al ras con Flush la parte top of superior del pléexisting wall plenum num existente Flange Brida Ubicaciones Mounting de Montaje Locations Alinee las Ubicaciones del Montaje 2 Instrucciones de Instalación PASO 3: Adhiera el Soporte Frontal al Plénum 1. Alinee el soporte frontal con el plénum. 2. Ajuste el soporte frontal al plénum con los 6 tornillos provistos. 3 Notas Impreso en Estados Unidos 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

GE RAVTRANS2 Guía de instalación

Tipo
Guía de instalación