ACF GreenHouse SureSTAT TS200 Instrucciones de operación

Categoría
Termostatos
Tipo
Instrucciones de operación

Este manual también es adecuado para

General Safety Information
Disconnect all power
before installing or
servicing this product. If the power
disconnect is out of view, lock it in the
open position and tag it to prevent
unexpected restarting of power. Failure to
do so could result in fatal electric shock.
1. Special attention must be given to any
grounding information on this product
and to other equipment associated with
its installation and use. To ensure a
proper ground, the grounding means
must be checked by a qualified
electrician.
2. Be certain that the electrical ratings of
the thermostat conform to the power
source and the load(s) being controlled.
Loads that exceed the rating of the
thermostat should be handled with a
suitable rated relay or motor starter.
Do not depend upon
the thermostat as the
sole means of disconnecting power when
installing or servicing the product it is
controlling. Always disconnect power
at the main circuit breaker as described
above. Failure to do so could result
in fatal electric shock.
3. This thermostat is intended ONLY for
permanent installation in accordance
with the United States National
Electrical Code (NEC), all applicable
local codes and ordinances, and all
sections of this manual. All wiring
should be done by a qualified
electrician, using copper wire only.
These thermostats
are intended for
general heating, ventilating, and
refrigeration ONLY. They must NOT be
used in potentially dangerous locations
such as flammable, explosive, chemical
laden areas.
These thermostats
are designed for use
as operating controls only. Where an
operating control failure would result in
personal injury and/or loss of property, it
is the responsibility of the installer to add
devices (safety, limit controls) or systems
(supervisory alarm systems) that protect
against, or warn of control failure.
In cases where
personal injury
or property damage may result from
malfunction of the thermostat, a backup
system must be used. Where critical or
high value products are maintained, an
approved temperature limit should be
wired in series with this thermostat.
In less critical applications, a second
thermostat with alarm contacts may
be used for redundancy.
Installation
LOCATION
Mount this product 5 to 6 feet (1.5 to
1.8 m) above the floor so it will be
exposed to the average temperature
of the controlled space. Do not mount
control where it could be affected by
unusual heat or cold such as in sunlight
or beside equip ment. Avoid locations near
a door, window or other opening. Do
not mount on an outside wall. When the
thermostat is mounted with coil pointed
down, it is protected from falling objects,
dirt, and debris.
MOUNTING – FIXED INSTALLATIONS
Four mounting holes for fixed installa -
tions are found in the back of the case.
On rough surfaces use the top mounting
holes only. When mounting this control
on uneven surfaces, when all four
mounting screws are tightened, the
housing may deform enough to affect
the thermostat calibration and operation.
Do not dent or deform
the sensor coil of
this control. A dent or deformation
will change the calibration and cause
the control to cycle at a temperature
lower than the knob setting.
HOW MODELS WITH AN ADJUSTABLE
DIFFERENTIAL OPERATE
Increased differential
subtracts from the
temperature setting. For example, if the
knob is set to 50°F, and the differential
is set to MAX, a heater would turn on
at approximately 35°F. For cooling, the
device would turn ON at 50°F, and OFF
at approximately 35°F.
Form PN10541
Printed in China
SureSTAT Thermostats
Operating Instructions
P
lease read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
y
ourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage!
R
etain instructions for future reference.
Description
These thermostats are designed for reliable heating and cooling applications. They
are made with high strength NEMA 4X rated plastic enclosures and may be mounted
indoors or outdoors. These models are protected from rain and may be washed down
with a hose but must not be exposed to standing water or be submerged.
Model TS110 – Single stage hard-wired thermostat
Model TS200 – Two stage (3°F differential between stages) hard-wired thermostat
Temperature Range: 30° to 110°F
Differential: 3°F fixed
Electrical Rating: Millivolt to 120 VAC
Maximum Electric Load: 16 amps at 120 VAC
GARANTIA LIMITADA
GARANTIA LIMITADA DE SURESTAT POR UN AÑO. SURESTAT LE GARANTIZA AL USUARIO ORIGINAL QUE LOS
M
ODELOS TRATADOS EN ESTE MANUAL DE LOS TERMOSTATOS DE VOLTAJE DE LÍNEA SURESTAT ESTAN LIBRES DE
DEFECTOS EN LA MANO DE OBRA O EL MATERIAL, CUANDO SE LES SOMETE A USO NORMAL, POR UN AÑO A PARTIR
DE LA FECHA DE COMPRA. CUALQUIER PARTE QUE SE HALLE DEFECTUOSA, YA SEA EN EL MATERIAL O EN LA MANO
DE OBRA, Y SEA DEVUELTA (CON LOS COSTOS DE ENVIO PAGADOS POR ADELANTADO) A UN CENTRO DE SERVICIO
AUTORIZADO DESIGNADO POR SURESTAT, SERA REPARADA O REEMPLAZADA (NO EXISTE OTRA POSIBILIDAD)
SEGUN LO DETERMINE SURESTAT. PARA OBTENER INFORMACION SOBRE LOS PROCEDIMIENTOS DE RECLAMO
CUBIERTOS EN LA GARANTIA LIMITADA, VEA LA SECCION “ATENCION OPORTUNA” QUE APARECE MAS ADELANTE.
ESTA GARANTIA LIMITADA CONFIERE AL COMPRADOR DERECHOS LEGALES ESPECIFICOS QUE VARIAN DE
JURISDICCION A JURISDICCION.
LIMITES DE RESPONSABILIDAD. EN LA MEDIDA EN QUE LAS LEYES APLICABLES LO PERMITAN, LA
RESPONSABILIDAD DE SURESTAT POR LOS DAÑOS EMERGENTES O INCIDENTALES ESTA EXPRESAMENTE EXCLUIDA.
LA RESPONSABILIDAD DE SURESTAT EXPRESAMENTE ESTA LIMITADA Y NO PUEDE EXCEDER EL PRECIO DE COMPRA
PAGADO POR EL ARTICULO.
EXCLUSION DE RESPONSABILIDAD DE LA GARANTIA. SE HAN HECHO ESFUERZOS DILIGENTES PARA
PROPORCIONAR INFORMACION E ILUSTRACIONES APROPIADAS SOBRE EL PRODUCTO EN ESTE MANUAL; SIN
EMBARGO, ESTA INFORMACION Y LAS ILUSTRACIONES TIENEN COMO UNICO PROPOSITO LA IDENTIFICACION DEL
PRODUCTO Y NO EXPRESAN NI IMPLICAN GARANTIA DE QUE LOS PRODUCTOS SEAN VENDIBLES O ADECUADOS
PARA UN PROPOSITO EN PARTICULAR NI QUE SE AJUSTAN NECESARIAMENTE A LAS ILUSTRACIONES O
DESCRIPCIONES. CON EXCEPCION DE LO QUE SE ESTABLECE A CONTINUACION, SURESTAT NO HACE NI AUTORIZA
NINGUNA GARANTIA O AFIRMACION DE HECHO, EXPRESA O IMPLICITA, QUE NO SEA ESTIPULADA EN LA
“GARANTIA LIMITADA” ANTERIOR.
Consejo Técnico y Recomendaciones, Exclusiones de Responsabilidad. A pesar de las prácticas, negociaciones
o usos comerciales realizados previamente, las ventas no deberán incluir el suministro de consejo técnico o asistencia
o diseño del sistema. SureSTAT no asume ninguna obligación o responsabilidad por recomendaciones, opiniones o
consejos no autorizados sobre la elección, instalación o uso de los productos.
Adaptación del Producto. Muchas jurisdicciones tienen códigos o regulaciones que rigen la venta, la construcción,
la instalación y/o el uso de productos para ciertos propósitos que pueden variar con respecto a los aplicables a las
zonas vecinas. Si bien se trata de que los productos SureSTAT cumplan con dichos códigos, no se puede garantizar su
conformidad y no se puede hacer responsable por la forma en que se instale o use su producto. Antes de comprar y
usar el producto, revise su aplicación y todos los códigos y regulaciones nacionales y locales aplicables y asegúrese
de que el producto, la instalación y el uso los cumplan.
Ciertos aspectos de limitación de responsabilidad no se aplican a productos al consumidor; es decir (a) algunas
jurisdicciones no permiten la exclusión ni limitación de daños incidentales o consecuentes, de modo que las
limitaciones o exclusiones anteriores quizás no apliquen en su caso; (b) asimismo, algunas jurisdicciones no permiten
limitar el plazo de una garantía implícita, por lo tanto, la limitación anterior quizás no aplique en su caso; y (c) por
ley, mientras la Garantía Limitada esté vigente no podrán excluirse ni limitarse en modo alguno ninguna garantía
implícita de comercialización o de idoneidad para un propósito en particular aplicables a los productos al consumidor
adquiridos por éste.
Atención Oportuna. Se hará un esfuerzo de buena fe para corregir puntualmente, o hacer otros ajustes, con
respecto a cualquier producto que resulte defectuoso dentro de los términos de esta garantía limitada. En el caso
de que encuentre un producto defectuoso y que esté cubierto dentro de los límites de esta garantía haga el favor
de escribir primero, o llame, al distribuidor a quien le compró el producto. Para cualquier producto que crea que
está defectuoso según la garantía limitada, póngase en contacto con:
S
íntoma Causa(s) Posible(s) Medida Correctiva
E
nfriamiento:
El ventilador o el sistema de
e
nfriamiento no funciona
E
l ventilador o el sistema
d
e enfriamiento funciona
continuamente
El sistema funciona en
f
orma inversa
C
alefacción:
L
a unidad de calefacción
n
o funciona
L
a unidad de calefacción
funciona continuamente
E
l sistema funciona en
f
orma inversa
1. Cableado inadecuado
2
. La perilla está dispuesta por encima
de la temperatura ambiente
1
. Cableado inadecuado
2
. La perilla está dispuesta por debajo
d
e la temperatura ambiente
Cableado inadecuado
1
. Cableado inadecuado
2. La perilla está dispuesta por debajo
de la temperatura ambiente
1
. Cableado inadecuado
2
. La perilla está dispuesta por encima
d
e la temperatura ambiente
C
ableado inadecuado
1. Revise el cableado
2
. Ajuste la perilla a una
temperatura más baja
1
. Revise el cableado
2
. Ajuste la perilla a una
t
emperatura más alta
Revise el cableado
1
. Revise el cableado
2. Ajuste la perilla a una
temperatura más alta
1
. Revise el cableado
2
. Ajuste la perilla a una
t
emperatura más baja
R
evise el cableado
T
abla de Identificación de Problemas
Instalación (Continuación)
2. Cuando los termostatos se encuentran
conectados a un sistema o dispositivo de
Calentamiento: Gire la perilla hacia la derecha
a una posición por encima de la temperatura
ambiente; la unidad de calefacción deberá
estar activada. Cuando se gira la perilla hacia
la izquierda (a un ajuste de temperatura
más baja), la unidad de calefacción deberá
apagarse aproximadamente en la posición
de ajuste de la perilla.
3. Termostatos con interrupción SPDT/SPDT
de 2 etapas: Si la conexión es similar a la
Figura 4, el ventilador deberá activarse a
aproximadamente la temperatura ambiente
y deberá cambiar a alta velocidad, al girarse
la perilla hacia la izquierda a un ajuste de
temperatura más baja. Si el cableado es
similar a la Figura 5, el moderador deberá
abrirse al girarse la perilla hacia la izquierda
(a un ajuste de temperatura más baja). Los
dispositivos deberán funcionar en la
secuencia inversa cuando se gira la
perilla hacia la derecha.
Operación
La Figura 8,gina 3 muestra el funcionamiento
de termostatos con interrupción SPDT/ SPDT
de 2 etapas. Si la temperatura aumenta con
respecto al ajuste de la perilla, el circuito entre
R e Y del interruptor de etapa baja (RYL) se
cierra. Simultáneamente, el circuito entre
R y B (RBL) se abre.
Si la temperatura aumenta más, el interruptor
de etapa alta funciona y cierra (RYH) mientras
abre simultáneamente (RBH). Se produce la
secuencia inversa si la temperatura desciende.
AVISO: No hay partes de repuesto disponibles.
No intente realizar ninguna reparación
en campo.
380 Greenhouse Drive
Buffalo Junction, VA 24529
1-888-888-9050
Installation (Continued)
Certain thermostats are supplied with a
cord and series plug for easy connection
to a 120V AC grounded receptacle. Hang
the thermostat near a 120V three prong
receptacle with a ground pin using the
hanging wire included in the package.
Plug the male prongs into the receptacle
and then plug the controlled equipment
into the female part of the plug. For best
results do not locate the thermostat near
an exterior wall or window and away
from the discharge of the equipment.
If an extension cord is required use only
one with a grounded 3 prong plug and
14 gage wire.
RAINTIGHT THERMOSTAT
INSTALLATION
These thermostats are designed for use
in wet or humid environments. They meet
NEMA 4X requirements when used with
approved watertight connectors (not
included).
To ensure water tightness, a UL listed
cord seal or conduit hub marked “4X”
should be tightened onto the conduit
before installing in the enclosure. A drip
loop must be used to prevent moisture
from entering the thermostat housing.
Make certain that all connectors are
securely tightened.
When reinstalling the cover, make sure
it is squarely positioned over the gasket.
Then uniformly tighten the screws, evenly
compressing the gasket to provide a
watertight seal. Do not overtighten.
MOUNTING – EXTENDABLE BULB
THERMOSTAT INSTALLATION
These thermostat models have a
sensor bulb attached to the end of an
extendable capillary tube. The sensor
bulb on these units is designed to monitor
temperature remotely from the control
module.
When extending the sensor, avoid
bending or kinking the extendable
capillary tube, as this will affect the
accuracy of the unit. Make sure that
any excess tubing is coiled beneath
the thermostat control module.
The control module should be located in a
c
onvenient place within a distance easily
reached by the thermostats’ extendable
sensing bulb.
Care should be taken to install the
sensing bulb where it will sense the
a
verage ambient temperature of the
area to be controlled.
F
or remote room installations, mount
the sensing bulb in a location where the
ambient air can easily circulate around
t
he sensing bulb. For cold room
installations, the sensing bulb may
also be mounted on the suction side of a
r
efrigerant line, and secured in position.
For duct installations, position the
s
ensing bulb where it is in the primary
air stream and avoid mounting the
sensing bulb close to hot pipes, cooling
coils, or other areas which may cause
an inaccurate reading.
For tank installations, the sensing
bulb can be inserted directly into the tank
fluid. Place the sensing bulb in a location
where the liquid will circulate around the
sensing bulb and where it is not affected
by extraneous temperatures. When
mounting in a tank:
First drain the system.
Then screw an approved boiler plug
into a pipe tapping (not supplied).
Position a packing nut on the capillary
tubing of the sensing bulb.
Slip the sensing bulb completely
through the boiler plug.
Put the composition disc and slotted
brass washers on the capillary tubing.
Slide the assembly into the boiler plug
and tighten the packing nut.
Refill the system and check for leaks.
Coil the excess capillary tubing, taking
care to avoid any crimps.
WIRING
IMPORTANT: All wiring should be
done in accordance with applicable
codes, ordinances and regulations. Use a
disconnect device and overload protection
to assure safe installation complying with
local and national codes. Figures 1, 2 and
3 illus trate typical wiring for control
of heating, cooling, refrigeration, and
combi nation heating/cooling control
systems (use copper conductors only).
NOTE 1: Letters R, B and Y (red, blue and
y
ellow) refer to color of paint dots near
terminals, or wire colors for some models
(see Figure A).
2
R
B
Y
H
Power Supply
(C) Common
To heating
system
B open on
temp. rise
Figure 1 – Connection for a Typical
Heating Control Circuit
R
B
Y
H
Power Supply
(C) Common
To fan motor or
refrigeration unit
Y close on
temp. rise
Figure 2 – Connection for a Typical
Refrigeration, Ventilation
or Cooling Control Circuit
Adjust
knob
Adjust
knob
NOTE: Terminal
B is not used on
SPDT models.
R
B
Y
Red Dot or Wire (Power)
Figure A
Adjust
knob
R
B
Y
R
B
Y
Figure B
Adjust
knob
Low temp.
switch
control
Jumper
Blue Dot or Wire (Heat)
Yellow Dot or Wire (Cool)
High temp.
switch
control
Red Dot
or Wire
(Power)
Blue Dot
or Wire
(Heat)
Yellow Dot
or Wire
(Cool)
Blue Dot
or Black
Wire (Heat)
Yellow Dot
or Brown
Wire (Cool)
Instalación (Continuación)
La Figura 4 muestra el cableado para
controlar un ventilador de ventilación de dos
velocidades. Cuando el elemento de control
alcanza los ajustes de la perilla, el interruptor
de baja temperatura arranca el ventilador a
velocidad baja. Si la temperatura ambiente
continúa aumentando, el interruptor de
temperatura alta le suministra alimentación
eléctrica al devanado de alta velocidad
del motor.
La Figura 5 muestra un SPDT/SPDT conectado
en forma típica para una aplicación de
ventilador de dos velocidades. El motor
moderador será energizado cuando la
temperatura alcanza el ajuste de la perilla.
Si la temperatura continúa aumentando,
el motor del ventilador será energizado
por el interruptor de temperatura alta.
Las unidades SPDT/SPDT también pueden
usarse para controlar un sistema combinado
de calefacción y ventilación o enfriamiento,
como se muestra en la Figura 6. Un aumento
de la temperatura con respecto al ajuste de
la perilla apagará el sistema de calefacción
cuando los contactos Rojo-Azul del interruptor
de temperatura baja se abran. Un aumento
de temperatura de aproximadamente 1.7ºC
(3°F) encenderá el ventilador o el sistema de
enfriamiento a través del conductor Rojo-
Negro o los contactos de mancha Roja
o mancha Amarilla del interruptor
de temperatura alta.
La Figura 7 ilustra el cableado típico de las
unidades SPDT/SPDT para controlar dos etapas
de calefacción. Al bajar la temperatura
ambiente al ajuste de la perilla, el interruptor
de temperatura alta cerrará el contacto Rojo-
Marrón o mancha Azul, mancha Amarilla, y la
primera etapa de calefacción se activará. Si la
temperatura continúa descendiendo (aprox.
1.7ºC [3°F]), el interruptor de temperatura baja
cerrará el contacto Rojo-Azul, y la segunda
etapa de calefacción se activará.
PROCEDIMIENTO DE VERIFICACION
Antes de concluir la instalación, será necesario
observar un ciclo completo de funcionamiento
para asegurarse que todos los componentes
estén funcionando correctamente. Verifique
el funcionamiento correcto en la siguiente
secuencia:
1. Cuando los termostatos se encuentran
conectados a Sistemas de Refrigeración,
Ventilación o Enfriamiento: Gire la perilla
hacia la derecha a una posición de ajuste
por encima de la temperatura ambiente.
El ventilador o el sistema de enfriamiento
deberá estar apagado. Cuando se gira la
perilla hacia la izquierda (a un ajuste de
temperatura más baja), el ventilador o el
sistema de enfriamiento deberá activarse
aproximadamente en la posición de ajuste
de la perilla.
H
R
B
Y
R
B
Y
Fuente de alimentación
(C) Común
Al motor del
ventilador
Consulte el
AVISO 2 y la
Figura B en
la sección de
CABLEADO
Figura 4 – Termostatos SPDT/SPDT de
Dos Etapas en Control de un
Ventilador de Ventilación
de Dos Velocidades
Temp.
baja
Velocidad
alta
Velocidad
baja
Puente
H
R
B
Y
R
B
Y
Fuente de alimentación
(C) Común
Al motor del
ventilador
Consulte el
AVISO 2 y la
Figura B en
la sección de
CABLEADO
Figura 5 – Termostatos SPDT/SPDT de Dos
Etapas en Control de un Ventilador
de Ventilación de Velocidad
Única y de un Motor Moderador
de Aumento de Volumen
Temp.
baja
Puente
Al motor mode -
rador o al motor
de un segundo
ventilador
H
R
B
Y
R
B
Y
Fuente de alimentación
(C) Común
Al sistema o motor
de calefacción
Consulte el
AVISO 2 y la
Figura B en
la sección de
CABLEADO
Figura 6 – Termostatos SPDT/SPDT de Dos
Etapas con Cambio Automático
en Control de Sistemas de
Calefacción y Enfriamiento
Temp.
baja
Puente
Al sistema de
enfriamiento
o ventilación
H
R
B
Y
R
B
Y
Fuente de alimentación
(C) Común
A la segunda etapa
de calefacción
Consulte el
AVISO 2 y la
Figura B en
la sección de
CABLEADO
Figura 7 – Termostatos SPDT/SPDT de
Dos Etapas en Control de
un Sistema de Calefacción
de Dos Etapas
Temp.
baja
Puente
A la primera
etapa de
calefacción
H
H
R
B
Y
R
B
Y
Figura 8 – Secuencia Operativa de Termostatos SPDT/SPDT de Dos Etapas
Temp. baja
Temp. alta
Descenso de temp.
RB bajo
cierra
Etapa
baja
RY bajo
abre
RB alto
cierra
RY alto
abre
Etapa
alta
RY alto
cierra
RB alto
abre
RY bajo
cierra
RB bajo
abre
Ajuste de temp.
Aumento de temp.
Perilla
de
ajuste
3-Sp
H
R
B
Y
Fuente de alimentación
(C) Común
Sistema de calefacción
Sistema de enfriamiento o
ventilación por ventilador
Figura 3 – Termostatos SPDT en Control
de Sistemas de Calefacción
o Ventilación
Perilla
de
ajuste
Perilla
de
ajuste
Perilla
de
ajuste
Perilla
de
ajuste
Installation (Continued)
Figure 4 shows wiring for controlling
a two-speed ventilating fan. When
the control element reaches the knob
settings, the low temperature switch
starts the fan on low speed. If the
ambient temperature continues to rise,
the high temperature switch supplies
power to the high-speed motor winding.
Figure 5 shows a typical SPDT/SPDT
connection for a two-speed fan
appli cation. The damper motor will
be ener gized when the temperature
reaches the knob setting. If the
temperature continues to rise, the
fan motor will be energized by the
high temperature switch.
SPDT/SPDT units can also be used to
control a combination heating and
ventilating or cooling system, as shown
in Figure 6. A temperature increase to
the knob setting will turn off the heating
system when the Red-Blue contacts of
the low temperature switch break. An
increase in tempera ture of about 3ºF will
turn on the fan or cooling system through
the Red-Black wire or Red dot, Yellow dot
contacts of the high temperature switch.
Figure 7 illustrates typical wiring for
S
PDT/SPDT units for control of two
heating stages. As the ambient
temperature decreases to the knob
s
etting, the high temperature switch
will make Red-Brown wire or Blue dot,
Yellow dot contact, turning on the first
s
tage of heating. If the temperature
continues to drop (about 3ºF) the low
temperature switch will make Red-Blue
c
ontact, turning on the second stage
of heating.
CHECKOUT PROCEDURE
Before leaving the installation, a complete
operating cycle should be observed
to ensure that all components are
functioning properly. Check for correct
operation in the following sequence:
1. When thermostats are connected to
Refrigeration, Ventilating, or Cooling
Systems: Turn knob clockwise to a
setting above ambient temperature.
Fan or Cooling System should be off.
When knob is turned counterclockwise
(to lower temperature setting), the
fan or cooling system should turn on
approximately at the knob setting.
H
R
B
Y
R
B
Y
Power Supply
(C) Common
To fan motor
See NOTE 2 &
Figure B under
the WIRING
section
Figure 4 – Two-stage SPDT/SPDT
Thermostats in Control of
a Two-speed Ventilating Fan
Adjust
knob
Low
temp.
High speed
Low
speed
Jumper
Power Supply
(C) Common
To fan motor
See NOTE 2 &
Figure B under
t
he WIRING
section
Figure 5 – Two-stage SPDT/SPDT
Thermostats in Control of
a Single-speed Ventilating
Fan and Volume Increase
Damper Motor
Adjust
knob
Low
temp.
Jumper
To damper
motor or second
fan motor
H
R
B
Y
R
B
Y
Power Supply
(C) Common
To heating
motor or system
See NOTE 2 &
Figure B under
the WIRING
section
Figure 6 – Two-stage SPDT/SPDT
Thermostats with Automatic
Changeover in Control of
Heating and Cooling Systems
Adjust
knob
Low
temp.
Jumper
To ventilating
or cooling
system
H
R
B
Y
R
B
Y
Power Supply
(C) Common
To second
stage heating
See NOTE 2 &
Figure B under
the WIRING
section
Figure 7 – Two-stage SPDT/SPDT
Thermostats in Control of
a Two-stage Heating System
Adjust
knob
Low
temp.
Jumper
To first
stage
heating
H
H
R
B
Y
R
B
Y
Figure 8 – Operational Sequence of Two-stage SPDT/SPDT Thermostats
Low temp.
High temp.
Temp. fall
RB low
closes
Low
stage
RY low
opens
RB high
closes
RY high
opens
High
stage
RY high
closes
RB high
opens
RY low
closes
RB low
opens
Temp. setting
Temp. rise
3
H
R
B
Y
Power Supply
(C) Common
Heating system
Vent fan or
cooling system
Figure 3 – SPDT Thermostats in Control
of Heating and Ventilation
Systems
Adjust
knob
I
nstalación (Continuación)
Algunos termostatos se proveen con un cable y
un conector en serie para facilitar la conexión a
un receptáculo de 12 V CA de conexión a tierra.
Con el cable colgante que se incluye en el
paquete, cuelgue el termostato cerca de un
receptáculo de 120 V de tres clavijas con un
pasador de seguridad a tierra. Conecte las tres
clavijas macho en el receptáculo y enseguida
conecte el equipo de control en la pieza
hembra del enchufe. Para obtener mejores
resultados, no coloque el termostato cerca de
una pared o ventana exteriores y lejos del sitio
de descarga del equipo. Si es necesario utilizar
un cable de extensión, use únicamente un
enchufe de 3 clavijas puesto a tierra y un
cable de calibre 14.
INSTALACION PARA TERMOSTATO
IMPERMEABLE
Estos termostatos están diseñados para
utilizarse en entornos húmedos o mojados.
Los termostatos cumplen con los requisitos
NEMA 4X cuando se utilizan con conectores
herméticos aprobados (no incluidos).
Para garantizar la hermeticidad, será necesario
sujetar un sello de cordón con clasificación
UL o una boca de conexión de conductos
con designación “4X” al conducto antes de
instalarlo en la caja. Se debe utilizar un lazo
de goteo para evitar que la humedad penetre
el alojamiento del termostato. Asegúrese que
todos los conectores estén debidamente
apretados.
Cuando vuelva a colocar la cubierta, asegúrese
que quede encuadrada sobre la empaqueta -
dura. Luego, apriete los tornillos de manera
uniforme, y comprima la empaquetadura
uniformemente para proporcionar un
sello hermético. No apriete demasiado.
MONTAJE – INSTALACION DE
TERMOSTATO CON FOCO EXTENSIBLE
Estos modelos de termostato incluyen un bulbo
sensor fijado en el extremo de un tubo capilar
extensible. El bulbo sensor en estas unidades
está diseñado para monitorizar la temperatura
de manera remota desde el módulo de control.
Cuando extienda el sensor, evite doblar o
plegar el tubo capilar extensible, ya que esto
afectará la precisión de la unidad. Asegúrese
que todo exceso de tubo esté enrollado detrás
del módulo de control del termostato.
El módulo de control debe ubicarse en un lugar
conveniente dentro de una distancia fácil de
alcanzar por el foco sensor extensible del
termostato.
Es necesario tener cuidado al instalar el foco
sensor donde detecte temperatura ambiente
promedio del área que será monitorizada.
Para instalaciones en habitaciones
remotas, instale el foco sensor en una
ubicación donde el aire ambiente pueda
circular con facilidad alrededor del foco sensor.
Para instalaciones en habitaciones frías,
también se puede instalar el foco sensor en el
lado de succión de una línea de refrigerante,
y asegurarlo en su posición.
Para instalaciones en conductos, ubique el
foco sensor donde se encuentre en el chorro de
aire principal y evite instalarlo cerca de tuberías
calientes, bobinas de enfriamiento u otras áreas
que puedan provocar una lectura imprecisa.
Para instalaciones en tanques, el foco sensor
puede insertarse directamente en el líquido
del tanque. Coloque el foco sensor en una
ubicación donde el líquido circule alrededor
del foco sensor y donde no esté expuesto a
temperaturas superfluas. Cuando lo instale
en un tanque:
Drene primero el sistema.
Luego enrosque un tapón de caldera
aprobado en el machuelo para tubo
(no suministrado).
Coloque una tuerca de estanqueidad en
el tubo capilar del foco sensor.
Deslice el foco sensor completamente a
través del tapón de caldera.
Coloque el disco de composición y las
arandelas ranuradas de latón en el
tubo capilar.
Deslice el conjunto en el tapón de caldera
y apriete la tuerca de estanqueidad.
Vuelva a llenar el sistema y revíselo
para verificar que no haya fugas.
Enrolle el exceso de tubo capilar,
cuidando de evitar rizados.
CABLEADO
IMPORTANTE: Todo el cableado deberá
hacerse de acuerdo con los códigos,
reglamentos y regulaciones aplicables.
Utilice un dispositivo de desconexión y una
protección contra sobrecarga para garantizar
una instalación segura que cumpla con los
códigos locales y nacionales. Las Figuras
1, 2 y 3 ilustran el cableado típico para
controlar los sistemas de control de calefacción,
enfriamiento, refrigeración y combinados
de calefacción y enfriamiento (se utiliza
sólo conductores de cobre).
AVISO 1: Las letras R, B e Y (rojo, azul y
amarillo) se refieren al color de las manchas
pintadas cerca de los terminales, o los colores
de los conductores para algunos de los
modelos (consulte la Figura A).
2-Sp
R
B
Y
H
Fuente de alimentación
(C) Común
Al sistema de
calefacción
B se abren por
aumento de la
temperatura
Figura 1 – Conexión para un Circuito Típico
de Control de Calefacción
R
B
Y
H
Fuente de alimentación
(C) Común
Al motor del
ventilador o unidad
de refrigeración
Y se cierran por
aumento de la
temperatura
Figura 2 – Conexión para un Circuito Típico
de Control de Refrigeración,
Ventilación o Enfriamiento
AVISO: El terminal B
no se usa en los
modelos SPDT.
Perilla
de
ajuste
Perilla
de
ajuste
R
B
Y
Mancha o Conductor
rojo (Alimentación)
Figura A
R
B
Y
R
B
Y
Figura B
Perilla
de
ajuste
Interruptor
de control
de baja
temperatura
Puente
Mancha o Conductor
azul (Calefacción)
Mancha o Conductor
amarillo (Enfriamiento)
Interruptor de
control de alta
temperatura
Mancha o Conductor
rojo (Alimentación)
Mancha o
Conductor azul
(Calefacción)
Mancha o
Conductor
amarillo
(Enfriamiento)
Mancha azul o
Conductor negro
(Calefacción)
Mancha amarilla
o Conductor
marrón
(Enfriamiento)
Perilla
de
ajuste
LIMITED WARRANTY
SURESTAT ONE-YEAR LIMITED WARRANTY. SURESTAT LINE VOLTAGE THERMOSTATS, MODELS
COVERED IN THIS MANUAL, ARE WARRANTED BY SURESTAT TO THE ORIGINAL USER AGAINST
DEFECTS IN WORKMANSHIP OR MATERIALS UNDER NORMAL USE FOR ONE YEAR AFTER DATE OF
PURCHASE. ANY PART WHICH IS DETERMINED TO BE DEFECTIVE IN MATERIAL OR WORKMANSHIP
AND RETURNED TO AN AUTHORIZED SERVICE LOCATION, AS SURESTAT DESIGNATES, SHIPPING
COSTS PREPAID, WILL BE, AS THE EXCLUSIVE REMEDY, REPAIRED OR REPLACED AT SURESTAT’S
OPTION. FOR LIMITED WARRANTY CLAIM PROCEDURES, SEE “PROMPT DISPOSITION” BELOW.
THIS LIMITED WARRANTY GIVES PURCHASERS SPECIFIC LEGAL RIGHTS WHICH VARY FROM
JURISDICTION TO JURISDICTION.
LIMITATION OF LIABILITY. TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, SURESTAT’S
LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES IS EXPRESSLY DISCLAIMED.
SURESTAT’S LIABILITY IN ALL EVENTS IS LIMITED TO AND SHALL NOT EXCEED THE PURCHASE
PRICE PAID.
WARRANTY DISCLAIMER. A DILIGENT EFFORT HAS BEEN MADE TO PROVIDE PRODUCT
INFORMATION AND ILLUSTRATE THE PRODUCTS IN THIS LITERATURE ACCURATELY; HOWEVER,
SUCH INFORMATION AND ILLUSTRATIONS ARE FOR THE SOLE PURPOSE OF IDENTIFICATION,
AND DO NOT EXPRESS OR IMPLY A WARRANTY THAT THE PRODUCTS ARE MERCHANTABLE,
OR FIT FOR A PARTICULAR PURPOSE, OR THAT THE PRODUCTS WILL NECESSARILY CONFORM
TO THE ILLUSTRATIONS OR DESCRIPTIONS. EXCEPT AS PROVIDED BELOW, NO WARRANTY OR
AFFIRMATION OF FACT, EXPRESSED OR IMPLIED, OTHER THAN AS STATED IN THE “LIMITED
WARRANTY” ABOVE IS MADE OR AUTHORIZED BY SURESTAT.
Technical Advice and Recommendations, Disclaimer. Notwithstanding any past practice or
dealings or trade custom, sales shall not include the furnishing of technical advice or assistance
or system design. SureSTAT assumes no obligations or liability on account of any unauthorized
recommendations, opinions or advice as to the choice, installation or use of products.
Product Suitability. Many jurisdictions have codes and regulations governing sales,
construction, installation, and/or use of products for certain purposes, which may vary from those
in neighboring areas. While attempts are made to assure that SureSTAT products comply with
such codes, SureSTAT cannot guarantee compliance, and cannot be responsible for how the
product is installed or used. Before purchase and use of a product, review the product
applications, and all applicable national and local codes and regulations, and be sure that the
product, installation, and use will comply with them.
Certain aspects of disclaimers are not applicable to consumer products; e.g., (a) some jurisdictions
do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you; (b) also, some jurisdictions do not allow a limitation
on how long an implied warranty lasts, consequently the above limitation may not apply
to you; and (c) by law, during the period of this Limited Warranty, any implied warranties of
implied merchantability or fitness for a particular purpose applicable to consumer products
purchased by consumers, may not be excluded or otherwise disclaimed.
Prompt Disposition. A good faith effort will be made for prompt correction or other
adjustment with respect to any product which proves to be defective within limited warranty.
For any product believed to be defective within limited warranty, contact:
Symptom Possible Cause(s) Corrective Action
Cooling:
Cooling or fan
does not operate
Cooling or fan
runs continuously
System operates in reverse
Heating:
Heating unit
does not operate
Heating unit
runs continuously
System operates in reverse
1. Improper wiring
2. Knob set above ambient
temperature
1. Improper wiring
2. Knob set below ambient
temperature
Improper wiring
1. Improper wiring
2. Knob set below ambient
temperature
1. Improper wiring
2. Knob set above ambient
temperature
Improper wiring
1. Check wiring
2. Set knob to lower
temperature
1. Check wiring
2. Set knob to higher
temperature
Check wiring
1. Check wiring
2. Set knob to higher
temperature
1. Check wiring
2. Set knob to lower
temperature
Check wiring
Troubleshooting Chart
Installation (Continued)
2. When thermostats are connected
to a Heating device or system: Turn
knob clockwise above the ambient
temperature; the heating unit should
be on. When knob is turned counter -
clockwise (to lower temperature
setting), the heating unit should turn
off approximately at the knob setting.
3. Thermostats with SPDT/SPDT 2 Stage
switching: If connection is similar
to Figure 4, fan should start at
approximately ambient temperature
and should change to high speed, as
the knob is turned counterclockwise
to a lower temperature setting. If
wiring is similar to Figure 5, the damper
should open as the knob is turned
counterclockwise (to lower temperature
setting). The devices should act in
reverse sequence when the knob is
turned clockwise.
Operation
Figure 8, page 3 illustrates the operation
of thermostats with SPDT/SPDT 2 Stage
switching. On a temperature increase to
the knob setting, the circuit between R
and Y of the low stage switch (RYL) closes.
Simultaneously the circuit between R
and B (RBL) opens.
On a further increase in temperature
the high stage switch operates and closes
(RYH) while simultaneously opening
(RBH). The reverse sequencing takes
place with a decrease in temperature.
NOTE: No Replacement parts available.
Do not attempt any field repair.
Formulario PN10541
Impreso en China
Información de Seguridad
General
Desconecte toda
la alimentación
eléctrica antes de instalar o darle
mantenimiento a este producto. Si
no es visible el punto de desconexión,
bloquéelo en la posición abierta y
coloque un aviso de advertencia para
evitar toda reconexión inesperada de
la alimentación eléctrica. Si no lo hace,
podría sufrir un choque eléctrico fatal.
1. Debe prestarse atención especial a cualquier
información de conexión a tierra en este
producto y a los otros equipos asociados
con su instalación y uso. Para garantizar
que la conexión a tierra sea efectiva, un
electricista calificado debe verificar los
medios de conexión a tierra.
2. Asegúrese que las capacidades eléctricas
del termostato coincidan con la fuente
de suministro eléctrico y la carga o cargas
siendo controladas. Las cargas que excedan
la capacidad del termostato deben
manejarse con un dispositivo de arranque
de motor o un relé de capacidad adecuada.
No dependa del
termostato como
el único medio de desconexión de la
alimentación eléctrica cuando instale o le
dé servicio al producto que el termostato
esté controlando. Siempre desconecte la
alimentación eléctrica en el interruptor
principal como se describe arriba. Si
no lo hace, podría sufrir un choque
eléctrico fatal.
3. Este termostato está diseñado UNICAMENTE
para instalación permanente de acuerdo con
el Código Eléctrico Nacional Estadounidense
(NEC), todos los códigos y reglamentos
locales aplicables y todas las secciones
de este manual. Se recomienda que un
electricista calificado realice todos los
trabajos de cableado, usando conductores
de cobre únicamente.
Estos termostatos
están diseñados
UNICAMENTE para calefacción, ventila-
ción y refrigeración general. NO deben
utilizarse en lugares posiblemente
peligrosos, tales como áreas donde
haya productos inflamables, explosivos
o químicos.
Estos termostatos
están diseñados
sólo para uso como controles de
funcionamiento. En donde un fallo
de control de funcionamiento fuera
a resultar en lesiones personales
y/o pérdida de la propiedad, será
el instalador quien tendrá la responsa -
bilidad de agregar dispositivos (de
seguridad, controles de límite) o sistemas
(sistemas supervisores con alarma) que
protejan contra o alerten de un fallo
de control.
En los casos donde
puedan ocurrir
lesiones personales o daño a la propie-
dad debido a un mal funcionamiento
del termostato, será necesario utilizar
un sistema de respaldo. En donde se
mantengan productos críticos o de
alto valor, deberá conectarse un límite de
temperatura aprobado en serie con este
termostato. En las aplicaciones menos
críticas, se puede utilizar un segundo
termostato con contactos de alarma
para tener redundancia.
Instalación
UBICACION
Monte este producto a una altura de 1.5 a
1.8 m (5 a 6 pies) sobre el piso para que quede
expuesto a la temperatura media del espacio
controlado. No monte el control donde podría
ser afectado por calor o frío inusual, tal como
bajo la luz del sol o al lado de equipos. Evite
los lugares cerca de puertas, ventanas u otras
aberturas. No lo monte en una pared exterior.
Cuando se monta el termostato con la bobina
orientada hacia abajo, se protege éste contra
los objetos que le puedan caer encima,
la suciedad y los restos de materiales.
MONTAJE – INSTALACIONES FIJAS
En la parte posterior de la caja encontrará
cuatro orificios de montaje para instalaciones
fijas. En superficies ásperas, use solamente los
orificios de montaje superiores. Cuando monte
este control en superficies irregulares, al
apretar los cuatro tornillos de montaje, es
posible que la caja se deforme lo suficiente
para afectar la calibración y el funcionamiento
del termostato.
No melle ni deforme
la bobina sensora
de este control. Una mella o una
deformación cambiará la calibración
y causará que el control cicle a una
temperatura más baja que la del
ajuste de la perilla.
COMO FUNCIONAN LOS MODELOS
CON UN DIFERENCIAL AJUSTABLE
Incremente los
substratos
diferenciales del ajuste de temperatura.
Por ejemplo, si la perilla se ajusta a 50°F
(10°C) el diferencial se ajusta a MAX,
un calentador se encenderá aproximada -
mente a 35°F (1.66°C). Para enfriamento
el dispositivo se encenderá a 50°F (10°C),
y se apagará aproximadamente a
35°F (1.66°C).
Termostatos SureSTAT
Instrucciones de Operación
P
or favor lea y guarde estas instrucciones. Léalas cuidadosamente antes de tratar de montar, instalar, operar o dar mantenimiento al producto aquí
d
escrito. Protéjase usted mismo y a los demás observando toda la información de seguridad.
¡
E
l no cumplir con las instrucciones puede ocasionar daños,
tanto personales como a la propiedad! Guarde estas instrucciones para referencia en el futuro.
Descripción
Estos termostatos están diseñados para un uso confiable en aplicaciones de calefacción y
ventilación. Se fabrican con cajas de plástico nominales NEMA 4 X de alta resistencia y pueden
montarse en interiores o exteriores. Estos modelos se encuentran protegidos contra la lluvia
y se pueden lavar sin más que con una manguera, pero no se deben exponer al agua o a
ser sumergidos.
Modelo TS110 – Termostato cableado de una etapa
Modelo TS200 – Dos etapas (3°F diferencial entre etapas ) termostato cableado
Gama de temperaturas: 30° a 110°F
Diferencial: 3°F fijo
Capacidad eléctrica: Millivoltio a 120 VCA
Carga eléctrica máxima: 16 amperios a 120 VCA
380 Greenhouse Drive
Buffalo Junction, VA 24529
1-888-888-9050
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

ACF GreenHouse SureSTAT TS200 Instrucciones de operación

Categoría
Termostatos
Tipo
Instrucciones de operación
Este manual también es adecuado para