Amplifier Probe
Instruction Sheet
Features
The Amplifier Probe is designed to identify and trace wires or cables within a group without damaging the insulation.
Works with any Tone Generator (62-160) to identify wires.
Battery cap allows quick and easy 9 volt battery replacement.
Volume control for increased sensitivity and adjustable to suit work environment.
Recessed ON/OFF button prevents battery drain.
Battery low indicator.
9 volt battery included.
Tip can be replaced without opening case.
Flat tip included.
Warning!
Do not touch to live AC circuits. This could cause an extreme shock hazard and damage the AMPLIFIER PROBE.
Instructions for Use
1) To trace a tone, connect the tone generator:
In working cables that are terminated:
Connect one lead of the IDEAL Tone Generator (62-160) to a terminated wire or cable and the other test lead to
earth or equipment ground(i.e. electrical box or conduit). (See Fig. 1)
In non-working or unterminated cables:
Connect one test lead of an IDEAL Tone Generator (62-160) to an unterminated wire and the other test lead to
another unterminated wire.
2) Press and hold the black ON/OFF button to turn on the amplifier probe.
3)
Adjust volume control to suit the environment. Volume can be increased to overcome noise or decreased to reduce
interference.
4) Hold tip of amplifier probe near wires or cables to be identified. The signal will be loudest on the wire or cable
with the generator attached to it. (Reception of the tone may be improved by separating the wires or cables from
the group)
To Change the TIP
1) Remove screw nearest to the the amplifier probe tip with a #1 Phillips screwdriver.
2) Pull the tip out of the front.
3) Push new tip into front.
4) Replace screw and tighten (about 4 in-lbs.), being careful not to over tighten.
Battery Replacement - Replace the battery when the battery low LED stays continuously on when the ON button is being
pressed.
1) Remove black rubber battery cap by pulling or prying off with hand. (See Fig. 2)
2) Remove and replace battery.
3) Snap rubber battery cap back into place.
Replacement Parts
LA-4144 Flat Probe Tip
LA-4145 Standard Point Probe Tip
Specifications
Power Requirements: One 9 volt battery
Battery Life (Alkaline, 540mA-hr): 50 hours typical
Probe tip resistance: 1,000 ohms min
Input Impedance: 5.7M ohm
Voltage Gain: 37dB
Mechanical: Dimensions – 9.2 x 1.7 x 1.2 inches, 233.7 x 66 x 3.05 cm, Weight – 5.0 oz. with battery (141 grams)
Sonda de amplificador
Hoja de instrucciones
Características
La sonda del amplificador está diseñada para identificar y rastrear conductores o cables dentro de un grupo sin dañar el aislamiento.
Funciona con cualquier generador de tonos (62-120) para identificar cables.
Tapa de la pila que permite un reemplazo rápido y sencillo de la pila de 9 voltios.
Control de volumen para mayor sensibilidad y ajustable para adaptarse al entorno de trabajo.
Botón empotrado de ENCENDIDO/APAGADO que impide el drenaje de la pila.
Indicador de pila poco cargada.
Se incluye una pila de 9 voltios.
La punta puede reemplazarse sin abrir la caja.
Punta plana incluida.
¡Advertencia!
No lo ponga en contacto con circuitos activos de CA. Esto puede causar un peligro extremo de electrocución y daños en la SONDA DEL AMPLIFICADOR.
Instrucciones de empleo
1) Para rastrear un tono, conecte el generador de tonos:
En cables que funcionan terminados:
Conecte un cable del generador de tonos IDEAL (62-160) a un conductor o cable terminado y el otro cable de prueba a tierra o conexión a tierra del equipo (es
decir, caja eléctrica o conducto). (Vea la Fig. 1)
En cables que no funcionan o sin terminar:
Conecte un cable de prueba a un generador de tonos IDEAL (62-160) a un cable sin terminar y el otro cable de prueba a otro cable sin terminar.
2) Pulse y mantenga pulsado el botón negro de ENCENDIDO/APAGADO para encender la sonda amplificadora.
3) Ajuste el control de volumen para adaptarse al entorno. Se puede aumentar el volumen para superar el ruido o disminuirlo para reducir la interferencia.
4) la punta de la sonda del amplificador junto a los conductores o cables que se vayan a identificar. La señal será más ruidosa en el conductor o cable con el gen-
erador conectado al mismo. (La recepción del tono puede mejorarse separando los conductores o cables del grupo)
Para cargar la PUNTA
1) Quite el tornillo más cercano a la punta de la sonda amplificadora con un destornillador Phillips No. 1.
2) Tire de la punta sacándola de la parte delantera.
3) Empuje la nueva punta en la parte delantera
4) Vuelva a poner el tornillo y apriételo (unas 4 lb-pulg), teniendo cuidado de sobrepasarse.
Reemplazo de la pila - Reemplace la pila cuando el LED de pila poco cargada esté continuamente encendido siempre que esté pulsado el botón de ENCENDIDO.
1) Quite la tapa de goma negra de la pila tirando de la misma o apalancándola con la mano. (Vea la Fig. 2)
2) Quite y reemplace la pila.
3) Vuelva a poner la tapa de goma en la pila.
Piezas de repuesto
Punta de sonda plana LA-4144
Punta de sonda plana estándar LA-4145
Especificaciones
Requisitos de energía: Una pila de 9 voltios
Duración de la pila (alcalina, 540 mA-h): 50 horas típico
Resistencia de la punta de la sonda: 1000 ohmios min
Impedancia de entrada: 5,7 M ohmios
Ganancia de voltaje: 37dB
Mecánicas: Dimensiones – 9,2" x 1,7" x 1,2" (23,4 x 6,6 x 3 cm) Peso – 5 onzas (141 g) con la pila
Fig. 2
BATTERY CAP
(Pull or pry off for easy battery
replacement)
BATTERY
LOW INDICATOR
(Solid light means
replace battery)
TIP CHANGE
SCREW (On bottom)
RECESSED
ON/OFF BUTTON
VOLUME
CONTROL
Fig. 1

Transcripción de documentos

Amplifier Probe Instruction Sheet BATTERY CAP (Pull or pry off for easy battery replacement) RECESSED ON/OFF BUTTON Features • The Amplifier Probe is designed to identify and trace wires or cables within a group without damaging the insulation. BATTERY • Works with any Tone Generator (62-160) to identify wires. LOW INDICATOR (Solid light means • Battery cap allows quick and easy 9 volt battery replacement. replace battery) • Volume control for increased sensitivity and adjustable to suit work environment. VOLUME • Recessed ON/OFF button prevents battery drain. CONTROL • Battery low indicator. • 9 volt battery included. TIP CHANGE SCREW (On bottom) • Tip can be replaced without opening case. • Flat tip included. Warning! Do not touch to live AC circuits. This could cause an extreme shock hazard and damage the AMPLIFIER PROBE. Instructions for Use 1) To trace a tone, connect the tone generator: Fig. 1 In working cables that are terminated: Connect one lead of the IDEAL Tone Generator (62-160) to a terminated wire or cable and the other test lead to earth or equipment ground(i.e. electrical box or conduit). (See Fig. 1) In non-working or unterminated cables: Connect one test lead of an IDEAL Tone Generator (62-160) to an unterminated wire and the other test lead to another unterminated wire. 2) Press and hold the black ON/OFF button to turn on the amplifier probe. Adjust volume control to suit the environment. Volume can be increased to overcome noise or decreased to reduce 3) interference. 4) Hold tip of amplifier probe near wires or cables to be identified. The signal will be loudest on the wire or cable with the generator attached to it. (Reception of the tone may be improved by separating the wires or cables from the group) To Change the TIP 1) Remove screw nearest to the the amplifier probe tip with a #1 Phillips screwdriver. 2) Pull the tip out of the front. 3) Push new tip into front. 4) Replace screw and tighten (about 4 in-lbs.), being careful not to over tighten. Battery Replacement - Replace the battery when the battery low LED stays continuously on when the ON button is being pressed. Fig. 2 1) Remove black rubber battery cap by pulling or prying off with hand. (See Fig. 2) 2) Remove and replace battery. 3) Snap rubber battery cap back into place. Replacement Parts LA-4144 Flat Probe Tip LA-4145 Standard Point Probe Tip Specifications Power Requirements: One 9 volt battery Battery Life (Alkaline, 540mA-hr): 50 hours typical Probe tip resistance: 1,000 ohms min Input Impedance: 5.7M ohm Voltage Gain: 37dB Mechanical: Dimensions – 9.2 x 1.7 x 1.2 inches, 233.7 x 66 x 3.05 cm, Weight – 5.0 oz. with battery (141 grams) Sonda de amplificador Hoja de instrucciones Características • La sonda del amplificador está diseñada para identificar y rastrear conductores o cables dentro de un grupo sin dañar el aislamiento. • Funciona con cualquier generador de tonos (62-120) para identificar cables. • Tapa de la pila que permite un reemplazo rápido y sencillo de la pila de 9 voltios. • Control de volumen para mayor sensibilidad y ajustable para adaptarse al entorno de trabajo. • Botón empotrado de ENCENDIDO/APAGADO que impide el drenaje de la pila. • Indicador de pila poco cargada. • Se incluye una pila de 9 voltios. • La punta puede reemplazarse sin abrir la caja. • Punta plana incluida. ¡Advertencia! No lo ponga en contacto con circuitos activos de CA. Esto puede causar un peligro extremo de electrocución y daños en la SONDA DEL AMPLIFICADOR. Instrucciones de empleo 1) Para rastrear un tono, conecte el generador de tonos: En cables que funcionan terminados: Conecte un cable del generador de tonos IDEAL (62-160) a un conductor o cable terminado y el otro cable de prueba a tierra o conexión a tierra del equipo (es decir, caja eléctrica o conducto). (Vea la Fig. 1) En cables que no funcionan o sin terminar: Conecte un cable de prueba a un generador de tonos IDEAL (62-160) a un cable sin terminar y el otro cable de prueba a otro cable sin terminar. 2) Pulse y mantenga pulsado el botón negro de ENCENDIDO/APAGADO para encender la sonda amplificadora. 3) Ajuste el control de volumen para adaptarse al entorno. Se puede aumentar el volumen para superar el ruido o disminuirlo para reducir la interferencia. 4) la punta de la sonda del amplificador junto a los conductores o cables que se vayan a identificar. La señal será más ruidosa en el conductor o cable con el generador conectado al mismo. (La recepción del tono puede mejorarse separando los conductores o cables del grupo) Para cargar la PUNTA 1) Quite el tornillo más cercano a la punta de la sonda amplificadora con un destornillador Phillips No. 1. 2) Tire de la punta sacándola de la parte delantera. 3) Empuje la nueva punta en la parte delantera 4) Vuelva a poner el tornillo y apriételo (unas 4 lb-pulg), teniendo cuidado de sobrepasarse. Reemplazo de la pila - Reemplace la pila cuando el LED de pila poco cargada esté continuamente encendido siempre que esté pulsado el botón de ENCENDIDO. 1) Quite la tapa de goma negra de la pila tirando de la misma o apalancándola con la mano. (Vea la Fig. 2) 2) Quite y reemplace la pila. 3) Vuelva a poner la tapa de goma en la pila. Piezas de repuesto Punta de sonda plana LA-4144 Punta de sonda plana estándar LA-4145 Especificaciones Requisitos de energía: Una pila de 9 voltios Duración de la pila (alcalina, 540 mA-h): 50 horas típico Resistencia de la punta de la sonda: 1000 ohmios min Impedancia de entrada: 5,7 M ohmios Ganancia de voltaje: 37dB Mecánicas: Dimensiones – 9,2" x 1,7" x 1,2" (23,4 x 6,6 x 3 cm) Peso – 5 onzas (141 g) con la pila