• 8 •
USING THE ENGINE START SETTING
Your battery charger can be used to jump
start your car if the battery is low. Follow
all safety instructions and precautions for
charging your battery. Wear complete eye
protection and protective clothing.
WARNING: Using the ENGINE START
setting WITHOUT a battery installed in
the vehicle could cause damage to the
vehicle’s electrical system.
NOTE: If you have charged the battery
and it still will not start your car, do not
use the Engine Start setting, or it could
damage the vehicle’s electrical system.
Have the battery checked.
1. With the charger unplugged from the
AC outlet, connect the charger to the
battery, following the instructions given
in Charging a Battery in the Vehicle.
2. With the charger plugged in and
connected to the battery of the vehicle,
press the BATTERY SIZE button until
the ENGINE START LED is lit. The
display mode will be automatically set to
VOLTAGE.
3. Crank the engine until it starts or 3
seconds pass. If the engine does not
start, wait 3 minutes before cranking
again. NOTE: During extremely cold
weather, or if the battery is under 2
volts, charge the battery for 5 minutes
before cranking the engine.
4. If the engine fails to start, charge the
battery for 5 more minutes before
attempting to crank the engine again.
5. After the engine starts, unplug the AC
power cord before disconnecting the
battery clamps from the vehicle.
NOTE: If the engine does turn over but
never starts, there is not a problem with
the starting system; there is a problem
somewhere else with the vehicle.
STOP cranking the engine until the
other problem has been diagnosed and
corrected.
ENGINE STARTING NOTES
During the starting sequence listed above,
the charger is set to one of three states.
Wait for cranking – The charger waits
until the engine is actually being cranked
before delivering the additional amps for
engine start. The charger delivers charge
at a rate of up to 12 amps while waiting
and will reset if the engine is not cranked
within 15 minutes. (If the charger resets, it
sets itself to the default start up settings).
While waiting for cranking, the digital display
shows the battery voltage (it cannot be set
to percent).
Cranking – When cranking is detected,
the charger will automatically deliver up
to its maximum output as required by
the starting system for up to 3 seconds
or until the engine cranking stops. The
digital display shows a countdown of the
remaining crank time, in seconds.
Cool Down – After cranking, the charger
enters a mandatory 3 minute (180 second)
cool down state. During this period, no
settings can be changed. The buttons are
ignored. The digital display indicates the
remaining cool down time in seconds.
It starts at 180 and counts down to 0. The
ENGINE START LED blinks once every
second. During the cool down period, no
current is delivered to the battery. After
3 minutes, the ENGINE START LED will
stop blinking and will light continuously,
indicating that another crank cycle can
be started. The digital display will change
from displaying the countdown back
to displaying the battery voltage. The
CHARGING LED will then be lit.
USING THE BATTERY VOLTAGE TESTER
1. With the charger unplugged from the
AC outlet, connect the charger to the
battery, following the instructions given
in previous sections.
2. Plug the charger AC power cord into
the AC outlet.
3. If necessary, press the BATTERY TYPE
button until the correct type is selected.
4. Read the voltage on the digital display
or press the Display Mode button to set
the tester to BATTERY %, to read the
voltage as a percent of charge. Keep in
mind that this reading is only a battery
voltage reading; a false surface
charge may mislead you. Compare the
voltage reading to the following chart.
6V Battery
Voltage
Reading
12V Battery
Voltage
Reading
Battery
Condition
6.4 or higher 12.8 or higher Charged
6.1 to 6.3 12.2 to 12.7
Needs
charging
Lower than 6.1
Lower than 12.2
Discharged
TESTER AND CHARGER
When rst turned on, the unit operates only
as a tester, not as a charger. To continue
to use it only as a tester, avoid pressing
the BATTERY SIZE button. Selecting a
charge rate activates the battery charger
and deactivates the tester. Pressing the
BATTERY SIZE button when the ENGINE
START LED is lit (except during the 180
second cool down) will shut off the charger
and activate the tester.