OPEN GROUND
OPEN NEUTRAL
OPEN HOT
CORRECT
HOT/GRD.
REVERSE
HOT/NEU.
REVERSE
ERT200
INSTRUCTION MANUAL
ENGLISH
ERT200
Electrical Receptacle
Tester w/ GFCI
WARRANTY
The ERT200 is warranted to be free from defects in materials
and workmanship for a period of one year from the date of
purchase. This warranty gives you specific legal rights. You
may also have other rights, which vary from state to state.
For more information on warranty and service:
www.ueitest.com • Email: [email protected]
1-800-547-5740 • FAX: (503) 643-6322
1. All appliances or equipment on the circuit being tested
should be unplugged to help avoid erroneous readings.
2. Not a comprehensive diagnostic instrument but a simple
instrument to detect nearly all probable common improper
wiring conditions.
3. Refer all indicated problems to a qualified electrician.
4. Will not indicate quality of ground
5. Will not detect 2 hot wires in circuit.
6. Will not detect a combination of defects
7. Will not indicate reversal of grounded and grounding conductors.
8. When testing GFCIs installed in 2-wire systems (no ground
wire available),the tester may give a false indication that
the GFCI is not functioning properly. If this occurs, recheck
the operation of the GFCI using the test and reset button. The
GFCI button test function will demonstrate proper operation.
GFCI TESTING
1. Check the GFCI receptacle user manual for information on
how your specific receptacle operates prior to using this
tester.
2. Insert the tester into the receptacle under test to check for
correct wiring (See Wiring Configuration Testing).
3. Operate the push button on the GFCI receptacle. Did the
GFCI trip and the tester lights go off?
YES -> Reset the GFCI by pressing the reset button. Proceed
to step 4.
NO -> The GFCI is not operating properly or the receptacle
is miswired. Consult a qualified electrician to rectify.
4. Press the test button on the tester for 7 seconds. Did the
GFCI trip and the tester lights go off?
YES -> Reset the GFCI. The GFCI appears to be operating
properly.
NO -> The GFCI is not operating properly or the receptacle
is miswired. Consult a qualified electrician to rectify.
5. When testing GFCIs installed in 2-wire systems (no ground
available), the tester may give a false indication that the GFCI
is not functioning properly. If this occurs, recheck the
operation of the GFCI using the test and reset button. The
GFCI button test function will demonstrate proper operation.
WARNING
Read, understand, and follow all warnings and instructions
before operating testers. Failure to follow instructions could
result in death or serious injury. Before each use, verify
tester operation by testing on a known live and correctly
wired receptacle. Do not use if the tester appears damaged
in any way. The tester is intended for indoor use only. Other
equipment or devices attached to the circuit being tested could
interfere with the tester. Clear the circuit before testing. Always
consult a qualified electrician to resolve wiring problems.
MANUAL DE INSTRUCCIONES
ESPAÑOL
ERT200
Probador de Tomacorrientes
eléctricos con interruptor GFCI
GARANTÍA
El ERT200 está garantizado a no tener defectos en
materiales y fabricación por un periodo de un año a partir
de la fecha de compra. Esta garantía le concede derechos
legales específicos. También puede tener otros derechos
que varían de un estado a otro.
Para obtener más información sobre garantía y servicio:
www.ueitest.com • Correo electrónico: [email protected]
1-800-547-5740 • FAX: (503) 643-6322
1. Todos los electrodomésticos o equipos que se encuentren en
el circuito que se está probando deben desconectarse a fin de
evitar errores de lectura.
2. No es un instrumento de diagnóstico integral, sino un
instrumento sencillo para detectar casi todas las condiciones
comunes de cableado incorrecto.
3. Refiera todos los problemas indicados a un electricista calificado.
4. No indica la calidad de la tierra.
5. No detecta 2 cables electrizados en el circuito.
6. No detecta una combinación de defectos.
7. No indica la inversión de conductores aterrizados y de aterrizado.
8. Al probar GFCI instalados en 2 sistemas de cableado (sin
cable de tierra disponible), el probador puede indicar
falsamente que el GFCI no está funcionando correctamente.
Si esto ocurre, vuelva a revisar la operación del GFCI usando
el botón de prueba y restablecimiento. La función de prueba
del botón GFCI demostrará la operación correcta.
Comprobación de interruptores GFCI
1. Consulte el manual del usuario del tomacorriente con
interruptor GFCI para obtener información sobre cómo
funciona su tomacorriente específico antes de utilizar este
probador.
2. Inserte el probador en el tomacorriente que se vaya a
comprobar para verificar si el cableado es correcto (consulte
“Comprobación de la configuración de cableado”).
3. Opere el botón pulsador del tomacorriente con interruptor
GFCI. ¿Saltó el GFCI y las luces del probador se apagaron?
-> Restablezca el GFCI presionando el botón de
restablecimiento. Vaya al paso 4.
NO -> El GFCI no está funcionando apropiadamente o el
tomacorriente está cableado incorrectamente.
Consulte a un electricista calificado para que lo
rectifique.
4. Presione el botón de prueba del probador durante 7 segundos.
¿Saltó el GFCI y se apagaron las luces del probador?
-> Restablezca el GFCI. Parece que el GFCI está
funcionando apropiadamente.
NO -> El GFCI no está funcionando apropiadamente o el
tomacorriente está cableado incorrectamente.
Consulte a un electricista calificado para que lo
rectifique.
5. Al probar el GFCI instalados en sistemas de 2 hilos (no tierra),
el probador puede dar una indicación falsa de que el GFCI
no está funcionando correctamente. Si esto ocurre, vuelva a
verificar el funcionamiento del GFCI usando la prueba y
el botón reset. La función de prueba GFCI botón hará una
demostración de funcionamiento.
ADVERTENCIAS
Lea, entienda y siga todas las advertencias e instrucciones antes
de utilizar los probadores. Si no se siguen las instrucciones, el
resultado podría ser la muerte o lesiones graves. Antes de cada
uso, verifique el funcionamiento del probador haciendo pruebas
en un tomacorriente que se sepa que tiene corriente y que
está cableado correctamente. No utilice el probador si parece
estar dañado de alguna manera. El probador está diseñado
para uso en lugares interiores solamente. Otros equipos o
dispositivos conectados al circuito que se esté comprobando
podrían interferir con el probador. Despeje el circuito antes de
realizar comprobaciones con el probador. Consulte siempre a un
electricista calificado para resolver los problemas de cableado.
Copyright © 2018 Kane USA, Inc. All Rights Reserved.
ERT200_MAN.indd 1-3 6/18/18 12:32 PM

Transcripción de documentos

ERT200 Electrical Receptacle Tester w/ GFCI ERT200 INSTRUCTION MANUAL ENGLISH OPEN GROUND OPEN NEUTRAL OPEN HOT HOT/GRD. REVERSE HOT/NEU. REVERSE CORRECT WARRANTY The ERT200 is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase. This warranty gives you specific legal rights. You may also have other rights, which vary from state to state. For more information on warranty and service: www.ueitest.com • Email: [email protected] 1-800-547-5740 • FAX: (503) 643-6322 ERT200 Probador de Tomacorrientes eléctricos con interruptor GFCI MANUAL DE INSTRUCCIONES ESPAÑOL GARANTÍA El ERT200 está garantizado a no tener defectos en materiales y fabricación por un periodo de un año a partir de la fecha de compra. Esta garantía le concede derechos legales específicos. También puede tener otros derechos que varían de un estado a otro. Para obtener más información sobre garantía y servicio: www.ueitest.com • Correo electrónico: [email protected] 1-800-547-5740 • FAX: (503) 643-6322 1. Todos los electrodomésticos o equipos que se encuentren en el circuito que se está probando deben desconectarse a fin de evitar errores de lectura. 2. No es un instrumento de diagnóstico integral, sino un instrumento sencillo para detectar casi todas las condiciones comunes de cableado incorrecto. 3. Refiera todos los problemas indicados a un electricista calificado. 4. No indica la calidad de la tierra. ERT200_MAN.indd 1-3 1. All appliances or equipment on the circuit being tested should be unplugged to help avoid erroneous readings. 2. Not a comprehensive diagnostic instrument but a simple instrument to detect nearly all probable common improper wiring conditions. 3. Refer all indicated problems to a qualified electrician. 4. Will not indicate quality of ground 5. Will not detect 2 hot wires in circuit. 6. Will not detect a combination of defects 7. Will not indicate reversal of grounded and grounding conductors. 8. When testing GFCIs installed in 2-wire systems (no ground wire available),the tester may give a false indication that the GFCI is not functioning properly. If this occurs, recheck the operation of the GFCI using the test and reset button. The GFCI button test function will demonstrate proper operation. GFCI TESTING 1. Check the GFCI receptacle user manual for information on how your specific receptacle operates prior to using this tester. 2. Insert the tester into the receptacle under test to check for correct wiring (See Wiring Configuration Testing). 3. Operate the push button on the GFCI receptacle. Did the GFCI trip and the tester lights go off? YES -> Reset the GFCI by pressing the reset button. Proceed to step 4. 5. 6. 7. 8. No detecta 2 cables electrizados en el circuito. No detecta una combinación de defectos. No indica la inversión de conductores aterrizados y de aterrizado. Al probar GFCI instalados en 2 sistemas de cableado (sin cable de tierra disponible), el probador puede indicar falsamente que el GFCI no está funcionando correctamente. Si esto ocurre, vuelva a revisar la operación del GFCI usando el botón de prueba y restablecimiento. La función de prueba del botón GFCI demostrará la operación correcta. Comprobación de interruptores GFCI 1. Consulte el manual del usuario del tomacorriente con interruptor GFCI para obtener información sobre cómo funciona su tomacorriente específico antes de utilizar este probador. 2. Inserte el probador en el tomacorriente que se vaya a comprobar para verificar si el cableado es correcto (consulte “Comprobación de la configuración de cableado”). 3. Opere el botón pulsador del tomacorriente con interruptor GFCI. ¿Saltó el GFCI y las luces del probador se apagaron? SÍ -> Restablezca el GFCI presionando el botón de restablecimiento. Vaya al paso 4. NO -> El GFCI no está funcionando apropiadamente o el tomacorriente está cableado incorrectamente. Consulte a un electricista calificado para que lo rectifique. 4. Presione el botón de prueba del probador durante 7 segundos. NO -> The GFCI is not operating properly or the receptacle is miswired. Consult a qualified electrician to rectify. 4. Press the test button on the tester for 7 seconds. Did the GFCI trip and the tester lights go off? YES -> Reset the GFCI. The GFCI appears to be operating properly. NO -> The GFCI is not operating properly or the receptacle is miswired. Consult a qualified electrician to rectify. 5. When testing GFCIs installed in 2-wire systems (no ground available), the tester may give a false indication that the GFCI is not functioning properly. If this occurs, recheck the operation of the GFCI using the test and reset button. The GFCI button test function will demonstrate proper operation. WARNING Read, understand, and follow all warnings and instructions before operating testers. Failure to follow instructions could result in death or serious injury. Before each use, verify tester operation by testing on a known live and correctly wired receptacle. Do not use if the tester appears damaged in any way. The tester is intended for indoor use only. Other equipment or devices attached to the circuit being tested could interfere with the tester. Clear the circuit before testing. Always consult a qualified electrician to resolve wiring problems. Copyright © 2018 Kane USA, Inc. All Rights Reserved. ¿Saltó el GFCI y se apagaron las luces del probador? SÍ -> Restablezca el GFCI. Parece que el GFCI está funcionando apropiadamente. NO -> El GFCI no está funcionando apropiadamente o el tomacorriente está cableado incorrectamente. Consulte a un electricista calificado para que lo rectifique. 5. Al probar el GFCI instalados en sistemas de 2 hilos (no tierra), el probador puede dar una indicación falsa de que el GFCI no está funcionando correctamente. Si esto ocurre, vuelva a verificar el funcionamiento del GFCI usando la prueba y el botón reset. La función de prueba GFCI botón hará una demostración de funcionamiento. ADVERTENCIAS Lea, entienda y siga todas las advertencias e instrucciones antes de utilizar los probadores. Si no se siguen las instrucciones, el resultado podría ser la muerte o lesiones graves. Antes de cada uso, verifique el funcionamiento del probador haciendo pruebas en un tomacorriente que se sepa que tiene corriente y que está cableado correctamente. No utilice el probador si parece estar dañado de alguna manera. El probador está diseñado para uso en lugares interiores solamente. Otros equipos o dispositivos conectados al circuito que se esté comprobando podrían interferir con el probador. Despeje el circuito antes de realizar comprobaciones con el probador. Consulte siempre a un electricista calificado para resolver los problemas de cableado. 6/18/18 12:32 PM
  • Page 1 1
  • Page 2 2

UEi ERT200 El manual del propietario

Tipo
El manual del propietario