Technical Specications
Input
Nominal Voltage 380–480 V ac, 3Ph
Power Factor (PFC) EN61000-3-2 Class A
Inrush Current <25 A
Nominal Frequency 50/60 Hz
Output
Nominal Voltage 24 V (Adjustable from 24–28 V dc)
Current 10 A
Power 240 W
Power Boost 1.5 x nominal current for 4 s
Hold-up Time
>20 ms (full load, 380 V ac input @ Tamb +25°C) to
95% output voltage
Tolerance <2% overall
• Line Regulation <0.5%
• Load Regulation <0.5%
• Time and Temperature Drift <1%
Initial Voltage Setting 24.5 V ± 1%
Ripple <50 mVpp
Power Back Immunity 35 V dc
Parallel Operation Switch selectable
Overvoltage Protection >30.5 V dc, but <33 V dc auto recovery
Standards, Certications
Emissions
EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011,
EN55022 Radiated and Conducted including Annex A, EN61000-3-2
Immunity
EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level
4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4
Level 4 input and Level 3 output, EN61000-4-5 Isolation Class
4, EN61000-4-11, SEMI F47 Sag Immunity, EN61000-4-8,
EN61000-4-34, Transient protection according to VDE 0160/W2
over entire load range
Approvals
cULus Listed: UL 508, CSA C22.2 No. 107.1; : UL
60950-1/CSA C22.2 60950-1 2
nd
edition, UL 60079-15 and CAN/
CSA-E60079-15, Class I, Zone 2, AEx nC IIC Gc, Ex nC IIC U
hazardous locations; CE: IEC60950-1:2005 2
nd
edition, EN60950-
1:2006+A11:2009; ATEX: II 3 G Ex nC IIC Gc, DEMKO 11
ATEX 1105449U; EN60079-0:2009, EN60079-15:2010
Environmental Data
Ambient Temperature
Storage/Shipment: -40°C to +85°C
Operating: -25°C to +60°C at full load. Linear
derating to 50% of rated load from +60°C to +70°C
maximum. Convection cooling; no forced air required.
Degree of Protection IP20 (EN60529)
Recommended Minimum
Installation Clearance
25 mm above and below; 25 mm left and right. Do not
obstruct air ow.
Weight 1.54 lb. (700 g)
Technical Support
Datos Técnicos
Entrada
Voltaje Nominal 380–480 V ac, 3Ph
Factor de Potencia (PFC) EN61000-3-2 Clase A
Arranque <25 A
Frecuencia Nominal 50/60 Hz
Salida
Voltaje Nominal 24 V (Ajustable from 24–28 V dc)
Corriente 10 A
Potencia 240 W
Elevación de Potencia 1.5 x la corriente nominal por 4 s
Tiempo de Retención
>20 ms (la carga llena, 380 V ac entrada @ Tamb + 25°C)
a 95% de voltaje de salida
Tolerancia <± 2% en conjunto
• Regulación de Línea <0.5%
• Regulación de Carga <0.5%
• Desviación de Tiempo y Temp <1%
Ajuste Inicial de Voltaje 24.5 V ± 1%
Rizo <50 mVpp
Inmunidad de Potencia Inversa 35 V dc
Operación Paralela Interruptor seleccionable
Protección de Sobre Voltaje >30.5 V dc, pero <33 V dc recuperación automática
Estándares, Certicaciones
Emisiones
EN61000-6-2:2001, EN61000-6-3:2001, Clase B EN55011,
EN55022, Radiada Conducida incluida en el Anexo A, EN61000-3-2
Inmmunidad
EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Nivel 4,
EN61000-4-3 Nivel 3, EN61000-4-6 Nivel 3, EN61000-4-4 Nivel 4
entrada y nivel salida, EN61000-4-5 Aislamiento clase 4, EN61000-
4-11, SEMIF47 Inmunidad a Picos, EN61000-4-8, IEC61000-4-34,
Protección contra Transientes de acuerdo a VDE 0160/W2 sobre
todo el rango de la carga
Aprobaciones
cULus Listada: UL 508, CSA C22.2 No. 107.1; : UL
60950-1/CSA C22.2 60950-1 2
a
edición, UL 60079-15 and CAN/
CSA-E60079-15 Clase I, Zona 2, AEx nC IIC Gc, Ex nC IIC U
sitios peligrosos; CE: IEC60950-1:2005 2
a
edición, EN60950-
1:2006+A11:2009; ATEX: II 3 G Ex nC IIC Gc, DEMKO 11
ATEX 1105449U; EN60079-0:2009, EN60079-15:2010
Datos Ambientales
Temperatura Ambiente
Almacenamiento/Embarque: -40°C to +85°C
Carga nominal completa: -25°C a +60°C en
carga llena. Lineal derating a 50% de la carga valorada
de +60°C a +70°C máximo. La convección que refresca;
ningún aire forzado requirió.
Grado de Protección IP20 (EN60529)
Espacio Libre Mínimo
recomendado de Instalación
25 mm por encima y por debajo; 25 mm izquierda y
derecha. No obstruya ujo aéreo.
Peso 1.54 lb. (700 g)
Servicio Técnico
Données Techniques
Entrés
Valeur Nominale 380–480 V ac, 3Ph
Facteur de Puissance (PFC) EN61000-3-2 Classe A
Inrupption <25 A
Fréquence Nominale 50/60 Hz
Sortie
Valeur Nominale 24 V (Adjustable from 24–28 V dc)
Courant 10 A
Puissance 240 W
Puissance de Survoltage 1.5 x valeur nominale pendant 4 s
Temps de Tient
>20 ms (le chargement plein, 380 V ac d’entrée @
Tamb + 25°C) à 95% tension de production
Tolérance <± 2% en général
• Régulation de Ligne <0.5%
• Régulation de Charge <0.5%
• Décalage Temps et Température <1%
Réglage Initial du Courant 24.5 V ± 1%
Ondulation <50 mVpp
Contre Aliment. en Retour 35 V dc
Opération Parallèle Interrupteur à sélectionner
Protection Contre la Surtension >30.5 V dc, mais <33 V dc récupération automatique
Normes, Autorisations
Emissions Dégagées
EN61000-6-2:2001, EN61000-6-3:2001, Classe B EN55011,
EN55022 Conduites Annexe A incluse, EN61000-3-2
Immunité
EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Niveau 4,
EN61000-4-3 Niveau 3, EN61000-4-6 Niveau 3, EN61000-4-4
Niveau 4 alimentation et niveau 3 sortie, EN61000-4-5 classe
isolation 4, EN61000-4-11, SEMIF47 immunité sag, EN61000-4-
8, IEC61000-4-34, Transitoire Protection selon VDE 0160/W2
sur gamme de charge entière
Approbations
cULus Enuméré : UL 508, CSA C22.2 No. 107.1; : UL
60950-1/CSA C22.2 60950-1 2
nd
édition, UL60079-15 and CAN/
CSA-E60079-15 Classe I, Zone 2, AEx nC IIC Gc, Ex nC IIC U
lieux dangereux; CE : IEC60950-1:2005 2
nd
édition, EN60950-
1:2006+A11:2009; ATEX : II 3 G Ex nC IIC Gc, DEMKO 11
ATEX 1105449U; EN60079-0:2009, EN60079-15:2010
Données Climatiques
Température Ambiante
Stockage/transport : -40°C to +85°C
Pleine charge nominale : -25°C à +60°C au
chargement plein. Linéaire derating à 50% de
chargement évalué de +60°C à +70°C maximum. La
convection qui refroidit ; aucun air forcé a exigé.
Degrés de Protection IP20 (EN60529)
Installation Dégagement
Minimum recommandé
25 mm au dessus et au dessous; 25 mm à gauche
et à droite. Ne pas encombrer du ux d’air.
Poids 1.54 lb. (700 g)
Assistance Technique
LED Diagnostics
LED OK
Loss of
AC
Low AC No DC
High
Load
Overload Hot Too Hot
Input Green --- Yellow --- Green Green Green Green
Output Green --- Green --- Yellow Yellow Green ---
Alarm --- --- --- --- Yellow Red Yellow Yellow
Diagnostic DEL
DEL OK
Perte
de AC
AC bas
Pas de
DC
Charge
Importante
Surcharge Chaud
Trés
Chaud
Entrée Vert --- Jaune Vert Vert Vert Vert Vert
Sortie Vert --- Vert --- Jaune Jaune Vert ---
Alarme --- --- --- Rouge Jaune Rouge Jaune Jaune
Diagnósticos LED
LED OK
La Perdida
de AC
AC baja
No
DC
Alta
Carga
Sobrecarga Caliente
Muy
Caliente
Entrada Verde --- Amarillo --- Verde Verde Verde Verde
Salida Verde --- Verde --- Amarillo Amarillo Verde ---
Alarma --- --- --- --- Amarillo Rojo Amarillo Amarillo