OJ Electronics nSpire Touch WiFi Guía de inicio rápido

Tipo
Guía de inicio rápido

Este manual también es adecuado para

QUICK START GUIDE
GUIDE DE DÉMARRAGE RAPIDE
GUÍA DE INICIO RÁPIDO
CLASSIFICATION
The product is a Class II device (reinforced insulation) and must be con-
nected to the following leads:
Phase L1 (L) 120/208/240 V
Neutral L2 (N)
Max. load 15 A (resistive load)
The Thermostat is to be used with underfloor heating.
The terminals are suitable for field wiring cables of 12 to 22 AWG.
Heating element in accordance with the supply voltage.
TECHNICAL DATA
Supply Range .........................................................120/240 Vac 50/60 Hz
Load ................................................................. max. 15 A (resistive load)
Max. power at e.g. ......................................................1800 W at 120 Vac
.................................................................................... 3120 W at 208 Vac
.................................................................................... 3600 W at 240 Vac
a. UWG4 (GFCI) .................................................. Class A (5 mA trip level)
b. AWG4 (EGFPD) ..........................................................(15 mA trip level))
Temperature range .....................................+5 to +40°C / +41 to +104°F
Amb. temp. range ..........................................0 to +25°C / +32 to +77°F
WIFI . ............................................................................ IEEE 802.11 b/g/n
Contains FCC ID ........................................................ 2ACSV-HF-LPT230
Contains IC ID ............................................................12243A-HFLPT230
Construction of Control ..................................Electronic room thermostat
for regulating electrical underfloor heating.
Method of Mounting Control ................................ Independently mounted
control for flush mounting
Type of Action ............................................................................. Type 2.B.
Rated Impulse Voltage ...................................................................2500 V
Control Pollution Degree ......................................................................... 2
USA - Design Patent No. ............................................................. D768092
Canada No. ................................................................................... 161353
This product uses FreeRTOS (www.FreeRTOS.org) and ChibiOS/RT.
CERTIFICATION
UL Listed for the US and Canada
According to the following standards:
Thermostat: UL 60730-1, UL 60730-2-9
CSA E60730-1, CSA E60730-2-9
UL file number: E157297
a. UWG4 GFCI: UL 943 4th ed.
CSA C22.2 No. 144.1-06
b. AWG4 EGFPD UL 1053
CSA C22.2 No. 0.8
Patent pending.
HOME SCREEN / ÉCRAN D’ACCUEIL / PANTALLA INICIAL
WARNINGS:
To avoid electric shock, disconnect the heating system power supply
at the main panel before installation and maintenance of the thermostat. Keep
thermostat air vents clean and free from obstruction. This thermostat is an
electrical device and must be installed in compliance with national and/or local
electrical codes. Installation must be performed by qualified personnel where
required by law.
If a power module with an equipment ground fault protection device (EGFPD)
is to be installed where national and/or local electrical codes require a ground
fault circuit interrupter (GFCI), a separate GFCI must also be installed.
AVERTISSEMENTS :
Pour éviter l’électrocution, coupez l’alimentation du système de chauage au
panneau principal avant de faire l’installation et/ou l’entretien du thermostat.
Maintenez les évents du thermostat propres et libres d’obstruction. Ce ther-
mostat est un appareil électrique et doit être installé conformément aux codes
électriques nationaux et/ou locaux. L’installation doit être eectuée par du
personnel qualifié quand la loi l’exige.
Si un module de puissance possédant un circuit de protection contre les fuites
à la terre (EGFPD) doit être installé où les codes électriques nationaux et/ou
locaux requièrent un disjoncteur de fuite à la terre (DDFT), un DDFT séparé doit
aussi être installé.
ADVERTENCIAS:
Para evitar descargas eléctricas, desconecte el suministro de alimentación
eléctrica del sistema de calefacción en el panel principal antes de la instalación
y el mantenimiento del termostato. Mantenga limpios y libres de cualquier obs-
trucciones los orificios de ventilación de aire del termostato. Este termostato
es un dispositivo eléctrico y debe instalarse de conformidad con los códigos
eléctricos nacionales y/o locales. La instalación debe ser realizada por personal
cualificado donde así lo requiera la ley.
Si se va a instalar un módulo de potencia con un dispositivo de protección de
fallo a tierra del equipo (EGFPD) en un sitio donde los códigos eléctricos nacio-
nales y/o locales requieran el uso de un interruptor de circuito de fallo a tierra
(GFCI), se deberá instalar además un GFCI separado.
67432I 03/21 (MTE)
OJ Electronics A/S
Stenager 13B
DK-6400 Sønderborg
© 2021 OJ Electronics. All rights reserved.
This manual and parts thereof are protected under Danish and international copyright laws.
© 2021 OJ Electronics. Tous droits réservés.
Ce manuel et son contenu sont protégés par les lois internationales et danoises sur les
droits d’auteur.
© 2021 OJ Electronics. Reservados todos los derechos.
Este manual y partes del mismo están protegidas en virtud de las leyes danesas e
internacionales sobre derechos de propiedad intelectual.
UWG4/AWG4
WiFi Touch Thermostat
For support please contact your installer or retailer.
Pour le soutien, communiquez avec votre installateur ou votre détaillant.
Para obtener soporte técnico, comuníquese con su instalador
o con el vendedor minorista.
www.ojelectronics.com/UWG4-download
Scan the QR-code for full user manual.
Scannez le code QR pour obtenir le manuel complet de
l’utilisateur.
Escanee el código QR para obtener el manual de
usuario completo.
© 2021 OJ Electronics A/S · ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S
Distributor ID: ___________________________________
CLASIFICACIÓN
El producto es un dispositivo Clase II (isolation renforcée) y debe ser
conectado a los conductores siguientes:
Fase L1 (L) 120/208/240 V
Neutro L2 (N)
Carga máxima 15 A (carga resistiva)
El termostato está destinado a ser utilizado con calefacción por suelo
radiante.
Los terminales son adecuados para cables de cableado de campo,
calibre 12 a 22 AWG. Elemento calefactor de conformidad con el
voltaje de suministro.
DATOS TÉCNICOS
Rango alimentación eléctrica ..............................120/240 V CA, 50/60 Hz
Carga .............................................................. máx. 15 A (carga resistiva)
Potencia maxima en el ejemplo .................................1800 W a 120 V CA
...................................................................................3120 W a 208 V CA
...................................................................................3600 W a 240 V CA
a. UWG4 (GFCI) ..................................... Clase A (nivel de disparo 5 mA)
b. AWG4 (EGFPD) ...............................................(nivel de disparo 15 mA)
Rango de temperatura ................................. +5 a +40 °C / +41 a +104 °F
Rango de temperatura ambiente ...................... 0 a +25 °C / +32 a +77 °F
WIFI . ............................................................................ IEEE 802.11 b/g/n
Contiene FCC ID ........................................................ 2ACSV-HF-LPT230
Contiene IC ID . ...........................................................12243A-HFLPT230
Construcción del control ... .....................................Termostato electrónico
ambiente para regular la calefacción eléctrica de piso radiante.
Método de montaje de control ........................................Control instalado
independientemente para montaje a ras
Tipo de acción ............................................................................. Tipo 2.B.
Voltaje nominal de impulso ............................................................2500 V
Grado de contaminación de entorno para el control ............................... 2
La patente del diseño en EE. UU. es la N.° ................................. D768092
En Canadá es la N.° ...................................................................... 161353
Este producto utiliza FreeRTOS (www.FreeRTOS.org) y ChibiOS/RT.
CERTIFICACIÓN
En lista de UL para EE. UU. y Canadá
De conformidad con las normativas siguientes.
Termostato: UL 60730-1, UL 60730-2-9
CSA E60730-1, CSA E60730-2-9
Número de archivo UL: E157297
a. UWG4 GFCI: UL 943 4ta. edición
CSA C22.2 No. 144.1-06
b. AWG4 EGFPD UL 1053
CSA C22.2 No. 0.8
Pendiente en trámite.
CLASSIFICATION
Le produit est un appareil de classe II (isolation renforcée) et doit être
raccordé aux fils suivants :
Phase L1 (L) 120/208/240 V
Neutre L2 (N)
Charge maximum 15 A (charge résistive)
Le thermostat est conçu pour être utilisé avec des planchers chauf
-
fants.
Les borniers sont adéquats pour du câble de construction de 12 à 22
AWG. Élément chauant en fonction de la tension d’alimentation.
DONNÉES TECHNIQUES
Plage alimentation ................................................120/240 VCA 50/60 Hz
Charge .......................................................... Max. 15 A (charge résistive)
Puissance maxi par exemple au ..................................1800 W à 120 VCA
....................................................................................3120 W à 208 VCA
....................................................................................3600 W à 240 VCA
a. UWG4 (DDFT) ........................... Class A (niveau déclenchement 5 mA)
b. AWG4 (EGFPD) ....................................(niveau déclenchement 15 mA)
Plage de température .................................. +5 à +40 °C / +41 à +104 °F
Plage temp. amb. ............................................. 0 à +25 °C / +32 à +77 °F
WIFI ............................................................................ IEEE 802.11 b/g/n
Contient FCC ID ........................................................ 2ACSV-HF-LPT230
Contient IC ID ..............................................................12243A-HFLPT230
Construction du dispositif de commande ................................ Thermostat
électronique de pièce pour réguler un plancher chauant électrique.
Méthode de montage du dispositif ..............................Dispositif de com
-
mande à montage indépendant pour montage encastré
Action de type ........................................................................... Type 2.B.
Tension assignée de choc .............................................................. 2500 V
Milieu de pollution du dispositif de commande ...................................... 2
Brevet USA No ............................................................................D768092
Canada No .................................................................................... 161353
Ce produit utilise FreeRTOS (www.FreeRTOS.org) et ChibiOS/RT.
CERTIFICATION
Homologué UL pour É.-U. et Canada
Selon les normes suivantes:
Thermostat : UL 60730-1, UL 60730-2-9
CSA E60730-1, CSA E60730-2-9
UL file number : E157297
a. UWG4 GFCI: UL 943 4th ed.
CSA C22.2 No. 144.1-06
b. AWG4 EGFPD UL 1053
CSA C22.2 No. 0.8
En instance de brevet.
10
11
ITEMS / RÉF. / ELEMENTOS
Day and time
Jour et heure
Día y hora
Current temperature
Température actuelle
Temperatura actual
Heating indicator - when visible, system is heating.
Indicateur de chauage - quand visible, chauage en marche.
Indicador de calefacción; al estar visible, el sistema está calentando
Wireless connection indicator – see the manual for explanations
Indicateur de connexion sans fil – voir le manuel pour explications
Indicador de conexión inalámbrica – consultar las explicaciones en
el manual
Access Main Menu
Accès menu principal
Acceder al menú principal
Weather indication – see the manual for explanations
Indication météo – voir le manuel pour explications
Indicación del clima – consultar las explicaciones en el manual
Target temperature or setpoint
Température cible ou point de consigne
Temperatura objetivo o punto de ajuste
9
Next scheduled change
Prochain changement prévu
Próximo cambio programado
GFCI Test Button
Bouton d’essai DDFT
Botón de prueba del GFCI
GFCI Indicator
Indicateur GFCI
Indicador GFCI
On/O/GFCI Reset Button
Press to turn system ON
Hold toturn system OFF
Press to reset the GFCI
Bouton de réarmement, marche/arrêt/DDFT
Appuyez pour mettre en marche le système
Tenez pour fermer le système
Appuyez pour réarmer le DDFT
Encendido/apagado/botón de restablecimiento del GFCI
Pulsar para encender (ON) el sistema
Pulsar sin soltar para apagar (OFF) el sistema
Pulsar para restablecer el GFCI
6
7
8
2
1
3
4
5
1
3 4 5
7
9
2
6
10
11
8
BR1015A10b
© 2015 OJ Electronic A/S
A B
C D
A B C D
out
in / sensor
BR1015A09b
© 2015 OJ Electronic A/S
Install the power base into the electrical box.
Installez le bornier de puissance dans le boîtier électrique.
Instale la base de alimentación eléctrica en la caja eléctrica.
1 2 3
6
4
5
BR1015A09b
BR964A07a
BR1012C02aBR1012C03a
BR1015A10a
BR1015A01b
BR1015A08b
Secure the power base to the wall.
Fixez le bornier de puissance au mur.
Fije la base de alimentación eléctrica a la pared.
Loosen the screw at the bottom and remove the faceplate.
Do not attempt to remove the screw completely.
Desserrez la vis du bas et retirez la plaque frontale.
N’essayez pas d’enlever complètement la vis.
Afloje el tornillo en la parte inferior y retire la placa frontal.
No intente retirar completamente el tornillo.
*Refer to instructions included with expansion unit.
*Consultez les instructions incluses avec l’unité d’extension.
*Consulte las instrucciones incluidas con la unidad de expansión.
Turn power source OFF at breaker panel. Connect power supply wires to line
side and heating cable wiring to load side of power base.
AWG between 12 - 20.
Note! Do not detach the screws from the terminal.
When fastening the screws use a torque between 0.8 - 1.2 Nm / 0.6 - 0.9 lbf-ft.
Coupez l’alimentation par le disjoncteur du panneau électrique. Raccordez les fils
de l’alimentation au côté «Line», et les fils du câble chauant au côté «Load» du
bornier de puissance.
AWG 12 à 20.
Attention ! Ne pas les enlever des bornes.
Lors du serrage des vis utiliser un couple entre 0,8 et 1,2 Nm / 0.6 - 0.9 lbf-pi.
Apague la fuente de alimentación eléctrica en el panel de disyuntores. Conecte el
cableado de la fuente de alimentación al lado de línea y el cableado de la
calefacción al lado de carga de la base de alimentación eléctrica.
AWG entre 12-20.
¡Nota! No separe los tornillos completamente del terminal.
Al apretar los tornillos utilice un par entre 0,8 y 1,2 Nm / 0.6 - 0.9 lbf-pi.
Tighten screw at bottom.
Serrez la vis du bas.
Apriete el tornillo en la parte inferior.
Perform the system and GFCI tests. Once the thermostat setup is
complete, confirm “Your thermostat will start heating the floor” to
complete the startup wizard.
Eectuez les tests du système et du DDFT. Une fois l’installation du
thermostat complétée, confirmez “votre thermostat commencera à
chauer le plancher” pour compléter l’assistant de démarrage.
Realice las pruebas del sistema y del GFCI. Una vez que haya termi-
nado el ajuste del termostato, confirme “Su termostato comenzará a
calentar el piso” para completar el asistente de inicio.
cable through the hole in the power base.
Push the electrical wires to the back of the electrical box.
Le câble de la sonde de plancher doit être acheminé à la boîte de
jonction électrique hors du conduit contenant la section froide du
câble chauant. S’assurer que l’isolation du câblage électrique et
de la sonde de plancher dans la boîte de jonction n’est pas endom-
magée.
Passez le câble de la sonde de plancher dans le trou du bornier
de puissance.
Poussez les fils électriques au fond du boîtier électrique.
El cable del sensor de piso debe tenderse hasta la caja de
conexiones eléctricas en un conducto separado de los demás cables
eléctricos y del conductor frío del cable de calefacción. Asegúrese de
que el aislamiento del cableado eléctrico y del sensor de piso en la
caja de conexiones no esté dañado.
Pase el cable de sensor de piso a través del orificio en la base de
alimentación eléctrica.
Empuje los cables eléctricos hacia la parte trasera de la caja eléctrica.
The Floor sensor has no
polarity. Connect it to
terminals C and D.
La sonde de plancher n’a
pas de polarité. Raccordez-
la aux bornes C et D.
El sensor de piso no tiene
polaridad. Conéctelo a
terminales C y D.
Expansion unit connects
to termianals A and B*
L’unité d’extension se
raccorde aux bornes A et B*
La unidad de expansión se
conecta a los terminales A y B*
QUICK START GUIDE /GUIDE DE DÉMARRAGE RAPIDE/GUÍA DE INICIO RÁPIDO
The floor sensor cable
must be routed to the
junction box separate
from power wires
and the heating cable
cold lead. Ensure that
the insulation on the
electrical wiring and
the floor sensor inside
the junction box are
not damaged.
Thread the floor sensor
BR1015A08b
© 2015 OJ Electronic A/S
Floor Sensor
Sonde de plancher
Sensor de piso
BR1012A02a
© 2015 OJ Electronic A/S
BR1012A04a
© 2015 OJ Electronic A/S
© 2021 OJ Electronics A/S · ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S
BR1012A05a
© 2015 OJ Electronic A/S
BR1012A04a & BR1012A05a
3
2
120 / 240 VAC
L2(N)L1(L)
LINE
1800W / 3600W MAX 15A
LOAD
14
BR1015A01b
© OJ Electronics A/S
Line (N)
Line (L)
Load
no polarity
Load
no polarity
Make the sensor connections.
Faites le raccordement de la sonde.
Efectúe las conexiones del sensor.
7 8
Remount the faceplate.
Remontez la plaque frontale.
Vuelva a instalar la placa frontal.
The floor sensor is recommended placed in an non conductive
installation pipe, which is embedded in the floor. The pipe must be
sealed in the end and placed as high as possible in the concrete
layer.
The floor sensor must be centered in between the heating cable.
The power supply voltage must match the voltage rating of the
heating cable.
Il est recommandé de le placé la sonde de sol dans une conduite
d’installation non conductrice enfouie dans le sol.
La conduite doit être scellée aux bouts et localisée le plus haut
possible dans la couche de béton.
La sonde de sol doit être centrée entre les câbles de chauage.
La sonde de plancher doit être centrée entre deux passes de câble
chauant.
Se recomienda colocar el sensor de piso en un tubo de instalación
no conductor, que se encuentre incrustado en el piso. El tubo de-
berá estar sellado en el extremo y colocado lo más elevadamente
posible en la capa de hormigón.
El sensor de piso deberá centrarse entre los cables de
calefacción.
La tensión de la alimentación debe coindir con la del cable de
calefacción.
BR1012A01a
© 2015 OJ Electronic A/S
OJ Microline

Transcripción de documentos

67432I 03/21 (MTE) HOME SCREEN / ÉCRAN D’ACCUEIL / PANTALLA INICIAL 9 ITEMS / RÉF. / ELEMENTOS 1 2 3 4 UWG4/AWG4 1 Day and time Jour et heure Día y hora 8 2 Current temperature Température actuelle Temperatura actual 9 3 Heating indicator - when visible, system is heating. Indicateur de chauffage - quand visible, chauffage en marche. Indicador de calefacción; al estar visible, el sistema está calentando 10 4 Wireless connection indicator – see the manual for explanations Indicateur de connexion sans fil – voir le manuel pour explications Indicador de conexión inalámbrica – consultar las explicaciones en el manual 11 5 Access Main Menu Accès menu principal Acceder al menú principal 5 6 7 8 10 6 11 CLASSIFICATION The product is a Class II device (reinforced insulation) and must be connected to the following leads: • Phase L1 (L) 120/208/240 V • Neutral L2 (N) • Max. load 15 A (resistive load) • The Thermostat is to be used with underfloor heating. The terminals are suitable for field wiring cables of 12 to 22 AWG. Heating element in accordance with the supply voltage. TECHNICAL DATA Supply Range..........................................................120/240 Vac 50/60 Hz Load .................................................................. max. 15 A (resistive load) Max. power at e.g. ...................................................... 1800 W at 120 Vac .................................................................................... 3120 W at 208 Vac .................................................................................... 3600 W at 240 Vac a. UWG4 (GFCI)................................................... Class A (5 mA trip level) b. AWG4 (EGFPD)...........................................................(15 mA trip level)) Temperature range ......................................+5 to +40°C / +41 to +104°F Amb. temp. range ...........................................0 to +25°C / +32 to +77°F WIFI .............................................................................. IEEE 802.11 b/g/n Contains FCC ID ........................................................ 2ACSV-HF-LPT230 Contains IC ID .............................................................12243A-HFLPT230 Construction of Control ...................................Electronic room thermostat for regulating electrical underfloor heating. Method of Mounting Control................................. Independently mounted control for flush mounting Type of Action.............................................................................. Type 2.B. Rated Impulse Voltage ............................ ��������������������������������������� 2500 V Control Pollution Degree .......................................................................... 2 USA - Design Patent No. ..............................................................D768092 Canada No. .................................................................................... 161353 This product uses FreeRTOS (www.FreeRTOS.org) and ChibiOS/RT. WiFi Touch Thermostat 7 Weather indication – see the manual for explanations Indication météo – voir le manuel pour explications Indicación del clima – consultar las explicaciones en el manual Target temperature or setpoint Température cible ou point de consigne Temperatura objetivo o punto de ajuste CLASSIFICATION Le produit est un appareil de classe II (isolation renforcée) et doit être raccordé aux fils suivants : • Phase L1 (L) 120/208/240 V • Neutre L2 (N) • Charge maximum 15 A (charge résistive) • Le thermostat est conçu pour être utilisé avec des planchers chauffants. Les borniers sont adéquats pour du câble de construction de 12 à 22 AWG. Élément chauffant en fonction de la tension d’alimentation. DONNÉES TECHNIQUES Plage alimentation .................................................120/240 VCA 50/60 Hz Charge ........................................................... Max. 15 A (charge résistive) Puissance maxi par exemple au................................... 1800 W à 120 VCA .................................................................................... 3120 W à 208 VCA .................................................................................... 3600 W à 240 VCA a. UWG4 (DDFT)............................ Class A (niveau déclenchement 5 mA) b. AWG4 (EGFPD)..................................... (niveau déclenchement 15 mA) Plage de température ................................... +5 à +40 °C / +41 à +104 °F Plage temp. amb............................................... 0 à +25 °C / +32 à +77 °F WIFI ............................................................................. IEEE 802.11 b/g/n Contient FCC ID ......................................................... 2ACSV-HF-LPT230 Contient IC ID...............................................................12243A-HFLPT230 Construction du dispositif de commande................................. Thermostat électronique de pièce pour réguler un plancher chauffant électrique. Méthode de montage du dispositif ...............................Dispositif de commande à montage indépendant pour montage encastré Action de type ............................................................................ Type 2.B. Tension assignée de choc ............................................................... 2500 V Milieu de pollution du dispositif de commande ....................................... 2 Brevet USA No .............................................................................D768092 Canada No ..................................................................................... 161353 Ce produit utilise FreeRTOS (www.FreeRTOS.org) et ChibiOS/RT. CERTIFICATION UL Listed for the US and Canada According to the following standards: Thermostat: UL 60730-1, UL 60730-2-9 CSA E60730-1, CSA E60730-2-9 UL file number: E157297 a. UWG4 GFCI: UL 943 4th ed. CSA C22.2 No. 144.1-06 b. AWG4 EGFPD UL 1053 CSA C22.2 No. 0.8 CERTIFICATION Homologué UL pour É.-U. et Canada Selon les normes suivantes : Thermostat : UL 60730-1, UL 60730-2-9 CSA E60730-1, CSA E60730-2-9 UL file number : E157297 a. UWG4 GFCI: UL 943 4th ed. CSA C22.2 No. 144.1-06 b. AWG4 EGFPD UL 1053 CSA C22.2 No. 0.8 Patent pending. En instance de brevet. QUICK START GUIDE GUIDE DE DÉMARRAGE RAPIDE GUÍA DE INICIO RÁPIDO Next scheduled change Prochain changement prévu Próximo cambio programado GFCI Test Button Bouton d’essai DDFT Botón de prueba del GFCI GFCI Indicator Indicateur GFCI Indicador GFCI On/Off/GFCI Reset Button Press to turn system ON Hold toturn system OFF Press to reset the GFCI Bouton de réarmement, marche/arrêt/DDFT Appuyez pour mettre en marche le système Tenez pour fermer le système Appuyez pour réarmer le DDFT Encendido/apagado/botón de restablecimiento del GFCI Pulsar para encender (ON) el sistema Pulsar sin soltar para apagar (OFF) el sistema Pulsar para restablecer el GFCI WARNINGS: To avoid electric shock, disconnect the heating system power supply at the main panel before installation and maintenance of the thermostat. Keep thermostat air vents clean and free from obstruction. This thermostat is an electrical device and must be installed in compliance with national and/or local electrical codes. Installation must be performed by qualified personnel where required by law. If a power module with an equipment ground fault protection device (EGFPD) is to be installed where national and/or local electrical codes require a ground fault circuit interrupter (GFCI), a separate GFCI must also be installed. AVERTISSEMENTS : Pour éviter l’électrocution, coupez l’alimentation du système de chauffage au panneau principal avant de faire l’installation et/ou l’entretien du thermostat. Maintenez les évents du thermostat propres et libres d’obstruction. Ce thermostat est un appareil électrique et doit être installé conformément aux codes électriques nationaux et/ou locaux. L’installation doit être effectuée par du personnel qualifié quand la loi l’exige. Si un module de puissance possédant un circuit de protection contre les fuites à la terre (EGFPD) doit être installé où les codes électriques nationaux et/ou locaux requièrent un disjoncteur de fuite à la terre (DDFT), un DDFT séparé doit aussi être installé. ADVERTENCIAS: CLASIFICACIÓN El producto es un dispositivo Clase II (isolation renforcée) y debe ser conectado a los conductores siguientes: • Fase L1 (L) 120/208/240 V • Neutro L2 (N) • Carga máxima 15 A (carga resistiva) • El termostato está destinado a ser utilizado con calefacción por suelo radiante. Los terminales son adecuados para cables de cableado de campo, calibre 12 a 22 AWG. Elemento calefactor de conformidad con el voltaje de suministro. DATOS TÉCNICOS Rango alimentación eléctrica...............................120/240 V CA, 50/60 Hz Carga ............................................................... máx. 15 A (carga resistiva) Potencia maxima en el ejemplo .................................. 1800 W a 120 V CA ................................................................................... 3120 W a 208 V CA ................................................................................... 3600 W a 240 V CA a. UWG4 (GFCI) ...................................... Clase A (nivel de disparo 5 mA) b. AWG4 (EGFPD)................................................(nivel de disparo 15 mA) Rango de temperatura .................................. +5 a +40 °C / +41 a +104 °F Rango de temperatura ambiente....................... 0 a +25 °C / +32 a +77 °F WIFI .............................................................................. IEEE 802.11 b/g/n Contiene FCC ID......................................................... 2ACSV-HF-LPT230 Contiene IC ID .............................................................12243A-HFLPT230 Construcción del control... �������������������������������������Termostato electrónico ambiente para regular la calefacción eléctrica de piso radiante. Método de montaje de control..... ����������������������������������� Control instalado independientemente para montaje a ras Tipo de acción.............................................................................. Tipo 2.B. Voltaje nominal de impulso ..................... ��������������������������������������� 2500 V Grado de contaminación de entorno para el control................................ 2 La patente del diseño en EE. UU. es la N.° ..................................D768092 En Canadá es la N.° ....................................................................... 161353 Este producto utiliza FreeRTOS (www.FreeRTOS.org) y ChibiOS/RT. CERTIFICACIÓN En lista de UL para EE. UU. y Canadá De conformidad con las normativas siguientes. Termostato: UL 60730-1, UL 60730-2-9 CSA E60730-1, CSA E60730-2-9 Número de archivo UL: E157297 a. UWG4 GFCI: UL 943 4ta. edición CSA C22.2 No. 144.1-06 b. AWG4 EGFPD UL 1053 CSA C22.2 No. 0.8 Pendiente en trámite. © 2021 OJ Electronics A/S · ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S Para evitar descargas eléctricas, desconecte el suministro de alimentación eléctrica del sistema de calefacción en el panel principal antes de la instalación y el mantenimiento del termostato. Mantenga limpios y libres de cualquier obstrucciones los orificios de ventilación de aire del termostato. Este termostato es un dispositivo eléctrico y debe instalarse de conformidad con los códigos eléctricos nacionales y/o locales. La instalación debe ser realizada por personal cualificado donde así lo requiera la ley. Si se va a instalar un módulo de potencia con un dispositivo de protección de fallo a tierra del equipo (EGFPD) en un sitio donde los códigos eléctricos nacionales y/o locales requieran el uso de un interruptor de circuito de fallo a tierra (GFCI), se deberá instalar además un GFCI separado. Scan the QR-code for full user manual. Scannez le code QR pour obtenir le manuel complet de l’utilisateur. Escanee el código QR para obtener el manual de usuario completo. www.ojelectronics.com/UWG4-download For support please contact your installer or retailer. Pour le soutien, communiquez avec votre installateur ou votre détaillant. Para obtener soporte técnico, comuníquese con su instalador o con el vendedor minorista. Distributor ID: ___________________________________ OJ Electronics A/S Stenager 13B DK-6400 Sønderborg © 2021 OJ Electronics. All rights reserved. This manual and parts thereof are protected under Danish and international copyright laws. © 2021 OJ Electronics. Tous droits réservés. Ce manuel et son contenu sont protégés par les lois internationales et danoises sur les droits d’auteur. © 2021 OJ Electronics. Reservados todos los derechos. Este manual y partes del mismo están protegidas en virtud de las leyes danesas e internacionales sobre derechos de propiedad intelectual. QUICK START GUIDE /GUIDE DE DÉMARRAGE RAPIDE/GUÍA DE INICIO RÁPIDO Vuelva a instalar la placa frontal. in / sensor ABCD BR1015A10a AB BR1012A04a & BR1012A05a BR1015A09b out BR1015A09b © 2015 OJ Electronic A/S BR1012A04a © 2015 OJ Electronic A/S BR1015A10b © 2015 OJ Electronic A/S Efectúe las conexiones del sensor. L’unité d’extension se raccorde aux bornes A et B* La unidad de expansión se conecta a los terminales A y B* Secure the power base to the wall. *Refer to instructions included with expansion unit. Tighten screw at bottom. Fixez le bornier de puissance au mur. *Consultez les instructions incluses avec l’unité d’extension. Serrez la vis du bas. Fije la base de alimentación eléctrica a la pared. *Consulte las instrucciones incluidas con la unidad de expansión. Apriete el tornillo en la parte inferior. © 2021 OJ Electronics A/S · ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S BR1015A08b © 2015 OJ Electronic A/S 4 BR1015A08b BR1012C02a BR1012C03a BR1012A03a © 2015 OJ Electronic A/S Instale la base de alimentación eléctrica en la caja eléctrica. The floor sensor cable must be routed to the junction box separate from power wires and the heating cable cold lead. Ensure that the insulation on the electrical wiring and the floor sensor inside Floor Sensor the junction box are Sonde de plancher not damaged. Sensor de piso Thread the floor sensor cable through the hole in the power base. Push the electrical wires to the back of the electrical box. Le câble de la sonde de plancher doit être acheminé à la boîte de jonction électrique hors du conduit contenant la section froide du câble chauffant. S’assurer que l’isolation du câblage électrique et de la sonde de plancher dans la boîte de jonction n’est pas endommagée. Passez le câble de la sonde de plancher dans le trou du bornier de puissance. Poussez les fils électriques au fond du boîtier électrique. El cable del sensor de piso debe tenderse hasta la caja de conexiones eléctricas en un conducto separado de los demás cables eléctricos y del conductor frío del cable de calefacción. Asegúrese de que el aislamiento del cableado eléctrico y del sensor de piso en la caja de conexiones no esté dañado. Pase el cable de sensor de piso a través del orificio en la base de alimentación eléctrica. Empuje los cables eléctricos hacia la parte trasera de la caja eléctrica. 8 BR1012A05a © 2015 OJ Electronic A/S BR1012A02a © 2015 OJ Electronic A/S BR964A07a © 2015 OJ Electronic A/S Remontez la plaque frontale. Expansion unit connects to termianals A and B* BR1015A01b BR1015A01b © OJ Electronics A/S 7 Remount the faceplate. Faites le raccordement de la sonde. CD 3 6 Installez le bornier de puissance dans le boîtier électrique. El sensor de piso no tiene polaridad. Conéctelo a terminales C y D. L2(N) Afloje el tornillo en la parte inferior y retire la placa frontal. No intente retirar completamente el tornillo. La sonde de plancher n’a pas de polarité. Raccordezla aux bornes C et D. LINE Coupez l’alimentation par le disjoncteur du panneau électrique. Raccordez les fils de l’alimentation au côté «Line», et les fils du câble chauffant au côté «Load» du bornier de puissance. AWG 12 à 20. Attention ! Ne pas les enlever des bornes. Lors du serrage des vis utiliser un couple entre 0,8 et 1,2 Nm / 0.6 - 0.9 lbf-pi. Apague la fuente de alimentación eléctrica en el panel de disyuntores. Conecte el cableado de la fuente de alimentación al lado de línea y el cableado de la calefacción al lado de carga de la base de alimentación eléctrica. AWG entre 12-20. ¡Nota! No separe los tornillos completamente del terminal. Al apretar los tornillos utilice un par entre 0,8 y 1,2 Nm / 0.6 - 0.9 lbf-pi. Desserrez la vis du bas et retirez la plaque frontale. N’essayez pas d’enlever complètement la vis. The Floor sensor has no polarity. Connect it to terminals C and D. 2 Line (N) Turn power source OFF at breaker panel. Connect power supply wires to line side and heating cable wiring to load side of power base. AWG between 12 - 20. Note! Do not detach the screws from the terminal. When fastening the screws use a torque between 0.8 - 1.2 Nm / 0.6 - 0.9 lbf-ft. Loosen the screw at the bottom and remove the faceplate. Do not attempt to remove the screw completely. Make the sensor connections. 3 L1(L) 5 Load no polarity 120 / 240 VAC 4 Il est recommandé de le placé la sonde de sol dans une conduite d’installation non conductrice enfouie dans le sol. La conduite doit être scellée aux bouts et localisée le plus haut possible dans la couche de béton. La sonde de sol doit être centrée entre les câbles de chauffage. La sonde de plancher doit être centrée entre deux passes de câble chauffant. Install the power base into the electrical box. Line (L) LOAD The floor sensor is recommended placed in an non conductive installation pipe, which is embedded in the floor. The pipe must be sealed in the end and placed as high as possible in the concrete layer. The floor sensor must be centered in between the heating cable. The power supply voltage must match the voltage rating of the heating cable. Se recomienda colocar el sensor de piso en un tubo de instalación no conductor, que se encuentre incrustado en el piso. El tubo deberá estar sellado en el extremo y colocado lo más elevadamente posible en la capa de hormigón. El sensor de piso deberá centrarse entre los cables de calefacción. La tensión de la alimentación debe coindir con la del cable de calefacción. Load no polarity 1 OJ Microline 2 1800W / 3600W MAX 15A BR1012A01a 1 Perform the system and GFCI tests. Once the thermostat setup is complete, confirm “Your thermostat will start heating the floor” to complete the startup wizard. Effectuez les tests du système et du DDFT. Une fois l’installation du thermostat complétée, confirmez “votre thermostat commencera à chauffer le plancher” pour compléter l’assistant de démarrage. Realice las pruebas del sistema y del GFCI. Una vez que haya terminado el ajuste del termostato, confirme “Su termostato comenzará a calentar el piso” para completar el asistente de inicio.
  • Page 1 1
  • Page 2 2

OJ Electronics nSpire Touch WiFi Guía de inicio rápido

Tipo
Guía de inicio rápido
Este manual también es adecuado para