Hunter Fan 24758 El manual del propietario

Tipo
El manual del propietario
Wall Control for Ceiling Fan
Wall Control Models: 24758
Ratings: 240 VAC, 1A Max
Read and Save these Instructions
WARNING! Risk of Electrical Shock
To avoid possible electrical shock, before wiring fan, disconnect
power by turning off the power mains both to the outlet box and to
its associated wall switch location.
Compliance
• This equipment has been tested and complies with: IEC 60669-1-1998
and EN 60669-1-1999.
• All wiring must be in accordance with national and local electrical codes.
If you are unfamiliar with wiring, you should use a qualied electrician.
In Australia, national laws require a qualied electrician to install
this control in accordance with national and local codes.
• To avoid over heating and possible damage to other equipment,
do not install to control a receptacle, uorescent light xture, motor
operated appliance, or transformer-supplied appliance.
Use only to control one ceiling fan.
For use only with electrically reversible ceiling fans rated at 1.0 A
or less.
Not for use with shaded-pole or nonreversible motors. Not
recommended for use with the Hunter Original
®
.
Faceplate Selection
Two styles of wall faceplates are provided. To remove the faceplate, hold
the faceplate assembly by the edges in both hands and press rmly with
your thumbs on opposite sides of the inner switch assembly until it snaps
out of the faceplate. See gure 1.
Press Here
Press Here
Figure 1 - Removing Switch Assembly from Faceplate.
To insert the switch assembly, center it in the opening of the alternate style
faceplate and press it into the faceplate until all six retaining tabs have
snapped into place, and the switch assembly is ush with the faceplate.
See Figure 2.
Figure 3 - Terminal Locations
© 2015 Hunter Fan Company 44301-01 01/23/15
Alternate Square Faceplate
Hunter Fan Company
7130 Goodlett Farms Pkwy, Ste 400
Memphis TN 38016 USA
Figure 4 - Terminal Setscrews, view from bottom
Fan Control
Fan Speed Control
To control the fan, set the fan speed control dial to the desired position
as shown in Figure 5. Positions are Off, High, Medium and Low from left
to right. The speed control pull chain on the fan itself must be set to High
for the wall control to function properly.
Figure 5 - Speed Control
Fan Speed
Control
Off
High
Medium
Low
Symptom
No functions
operate.
Possible Causes
Main Power not restored. Replace fuse. Turn ON
power mains. Turn ON
wall switch.
Verify wiring connections.
Fan pull chain not set to
HIGH.
Control wiring incorrect.
Solution
Turn OFF power at wall
switch or power mains.
Set fan to HIGH speed.
Troubleshooting
Setscrew (Fan Wire)
Fan
Setscrew
(VAC, not visible)
Power
Figure 2 - Switch Assembly insertion in Faceplate
Wiring
Disconnect the power to the ceiling fan at the main electric panel. Remove
fuse or move circuit breaker to the OFF position. Turn off wall switch.
The ends of the wire leads should be straight and have no more than 13 mm
of insulation removed. Before inserting wires into terminals, loosen the terminal
setscrews on each terminal enough to allow the easy insertion of the wire lead,
without removing the setscrew completely. See gures 3 and 4.
Connect the power wire to the terminal marked with the VAC icon and
tighten the setscrew rmly.
Connect the Fan wire to the terminal with the Fan icon. Tighten the
terminal setscrews rmly. See Figures 3 and 4 for reference.
Be sure no bare wire is exposed at the connection points. Push the wires
into the electrical box and mount the wall control assembly to the wall
electrical box using the two screws provided.
Power
Fan
5
24758
Hunter Fan
Company
Control de pared para ventilador
de techo
Modelos de control de pared: 24758
Capacidad: 240 VAC, 1 A máx.
Lea y guarde estas instrucciones
¡ADVERTENCIA! Riesgo de choque
eléctrico
Para evitar un choque eléctrico, antes de cablear el ventilador,
desconecte la energía de la red apagando la alimentación principal
a la caja de salida y a su interruptor de pared asociado.
Cumplimiento
• Este equipo se ha probado y cumple con las normas: IEC 60669-1-1998
EN 60669-1-1999.
• Todo cableado debe realizarse de acuerdo con los códigos eléctricos
nacionales y locales. Si no está familiarizado con el cableado, debe emplear
un electricista calicado.
• Para evitar el recalentamiento y daño a otros equipos, no realice la
instalación para controlar un receptáculo, artefacto de iluminación
uorescente, aparato operado por motor o alimentado por transformador.
Úselo sólo para controlar un ventilador de techo con hoja de paleta.
Sólo para uso con ventiladores de techo con inversión eléctrica de
rotación, de 1.0 amperio o menos.
No debe usarse con motores de polo sombreado o no reversibles. No se
recomienda su uso con el modelo Hunter Original
®
.
Selección de placa frontal
Se proporcionan dos estilos de placas frontales. Para retirar la placa
frontal, sostenga el conjunto de la placa por los bordes en ambas manos
y presione rmemente con sus pulgares en los lados internos opuestos
del conjunto del interruptor hasta que salga de la placa haciendo un clic.
Vea la Figura 1.
Presione
aquí
Presione aquí
Figura 1 - Retiro del conjunto del interruptor de la placa frontal.
Para introducir el conjunto del interruptor, céntrelo en la abertura de la
placa frontal alternativa y presiónelo dentro de la placa hasta que las seis
lengüetas de retención hayan entrado a presión en su lugar, y cuando el
conjunto del interruptor esté a nivel con la placa. Vea la Figura 2.
Figura 3 - Ubicación de los terminales
Placa frontal cuadrada alternativa
Alimentación
Ventilador
Control del ventilador
Control de velocidad del ventilador
Para controlar el ventilador, je el dial de control de velocidad del ventilador
en la posición deseada, como se muestra en la Figura 5. Las posiciones son
Apagado, Alta, Media y Baja de izquierda a derecha. La cadena de control
de velocidad en el mismo ventilador debe estar jada en Alta para que el
control de pared funcione correctamente.
Figura 5 - Control de velocidad
Control de
velocidad del
ventilador
Apagada
Alta
Media
Baja
Síntoma
No opera
ninguna función.
Causas posibles
La alimentación principal no
se ha restaurado.
Reemplace el fusible.
Encienda el suministro
principal de la red. Encienda
el interruptor de pared.
Verique las conexiones
del cableado.
La cadena del ventilador no
está jada en HIGH (alta)
Cableado de control
incorrecto.
Solución
Apague la alimentación en
el interruptor de pared o en
el suministro principal de
la red. Fije el ventilador en
velocidad HIGH (alta)
Localización de fallas
Tornillo de ajuste
(alambre del ventilador)
Ventilador
Tornillo de ajuste
(VAC, no visible)
Alimentación
Figura 2 - Introducción del conjunto del interruptor en la placa frontal
Cableado
Desconecte la alimentación de energía al ventilador de techo.
Retire el fusible o mueva el interruptor automático a la posición OFF
(desconectado) Apague el interruptor de pared.
Los extremos de los alambres deben estar rectos y no tener más de 13 mm de
aislamiento retirado. Antes de introducir los alambres en los terminales, aoje los
tornillos de ajuste de los terminales lo suciente para permitir la fácil introducción
de los alambres, pero sin retirar los tornillos por completo. Vea las Figuras 3 y 4.
Conecte el alambre de alimentación al terminal marcado con el icono VAC
y apriete rmemente su tornillo de ajuste.
Conecte al alambre del ventilador al terminal con el icono del ventilador
y apriete rmemente los tornillos de ajuste. Vea las Figuras 3 y 4 como
referencia.
Asegúrese de que no haya alambres pelados visibles en los puntos de
conexión. Empuje los alambres dentro de la caja eléctrica y monte el conjunto
del control de pared en la caja usando los dos tornillos suministrados.
24758
© 2015 Hunter Fan Company 41613-03 01/23/15
Hunter Fan Company
7130 Goodlett Farms Pkwy, Ste 400
Memphis TN 38016 USA
Hunter Fan
Company
Figura 4 - Tornillos de ajuste de los terminales, vista desde la parte inferior
Wandregler für Deckenventilator
Wandreglermodelle: 24757
Einstufung: 240 VAC, 1A Max
Lesen und bewahren Sie diese Hinweise
gut auf
WARNUNG! Stromschlaggefahr
Zur Vermeidung eines Stromschlages, stellen Sie vor dem
Anschließen des Ventilators das Stromnetz zum Stecker und den
dazu gehörigen Wandschalter ab.
Einhaltung von Industrienormen
• Dieses Gerät wurde getestet und entspricht: IEC 60669-1-1999 und
EN 60669-1.
• Jegliche Verkabelung muss nationalen und lokalen elektrischen
Vorschriften folgen. Wenn Sie sich nicht mit Verkabelung auskennen,
ziehen Sie einen qualizierten Elektriker zu Rate.
• Zur Vermeidung von Überhitzung und möglicher Beschädigung anderer
Geräte, nicht zur Bedienung von Steckdosen, Leuchtstofampen,
motorisierte oder transformatorbetriebene Geräte installieren.
Nur zur Bedienung von Flügel-Deckenventilatoren.
Nur zum Gebrauch mit elektrisch umkehrbaren Deckenventilatoren,
die mit 1,0A oder weniger eingestuft sind.
Nicht zum Gebrauch mit Schaltpol- oder Einweg-Motoren. Nicht
empfohlen im Gebrauch mit Hunter Original
®
.
Auswahl der Blende
Beiliegend sind zwei Arten Blenden. Zum Wechseln der Blende, halten
Sie die Blende mit beiden Händen an den Ecken und drücken Sie feste
mit den Daumen an gegenüberliegenden Seiten auf den inneliegenden
Schaltersatz bis er herausschnappt. Siehe Abbildung 1.
Hier drücken Hier drücken
Abbildung 1 - Wechseln der Blende
Um den Schaltersatz einzubauen, zentrieren Sie ihn in der Öffnung der
alternativen Blende und drücken Sie ihn in die Blende hinein bis alle
sechs Sicherungsklappen eingeschnappt sind und der Schaltersatz mit
der Blende bündig ist. Siehe Abbildung 2.
Abbildung 3 - Lage der Anschlüsse
Alternative Blende,
quadratisch
Strom
Ventilator
Ventilatoren-Regler
Ventilatoren-Geschwindigkeitsregler
Zur Betätigung des Ventilators stellen Sie den Geschwindigkeitsregler auf
die gewünschte Einstellung wie in Abbildung 5 gezeigt. Von links nach
rechts gibt es die Einstellungen Aus, Hoch, Mittel, Niedrig. Die Zugkette
zur Geschwindigkeitsregulierung am Ventilator selbst muss auf Hoch
gestellt werden, damit der Wandregler richtig funktionieren kann.
Abbildung 5 - Geschwindigkeitsregler
Ventilatoren-
Geschwindigkeitsregler
Aus
Hoch
Mittel
Niedrig
Merkmal
Keine Funktion
betriebsfähig
Mögliche Ursachen
Hauptschalter nicht wieder
angestellt
Sicherung ersetzen.
Stromnetz ANschalten.
Wandschalter anstellen.
Kabelverbindungen
nachprüfen.
Zugkette des Ventilators
nicht auf HOCH gestellt
Reglerverkabelung falsch.
Lösung
Strom zum Wandschalter
oder Stromnetz ABschalten.
Ventilatorgeschwindigkeit
auf HOCH stellen.
Fehlersuche
Stellschraube
(Ventilatorkabel)
Ventilator
Stellschraube (VAC,
nicht sichtbar)
Strom
Abbildung 2 - Einfügen des Schaltersatzes in die Blende
Verkabelung
Schalten Sie den Strom zum Deckenventilator an der Hauptschalttafel
aus. Entnehmen Sie die Sicherung oder stellen sie den Haupttrennschalter
auf AUS. Schalten Sie den Wandschalter ab.
Die Enden der Kabelleitungen sollten gerade sein und weniger als 13mm
Insulierung sollte entfernt sein. Bevor Kabel angeschlossen werden, lösen
Sie die Anschluss-Stellschrauben weit genug, sodass die Kabelleitung
leicht einzuführen ist, ohne dass die Stellschraube komplett entfernt wird.
Siehe Abbildung 3 und 4.
Schließen Sie das Elektrokabel an den Anschluss mit dem Symbol VAC
und ziehen Sie die Stellschraube fest an.
Schließen Sie das Ventilator-Kabel an den Anschluss an den Anschluss
mit dem Symbol und ziehen Sie die Stellschrauben fest an. Siehe
Abbildung 3 und 4.
Gehen Sie sicher, dass nirgendwo blankes Kabel an den
Verbindungspunkten ungeschützt ist. Stecken Sie die Kabel in die
elektrische Box und schrauben Sie den Wandreglersatz an die elektrische
Wanddose mit den zwei vorgesehenen Schrauben.
24758
© 2015 Hunter Fan Company 41613-04 01/23/15
Hunter Fan Company
7130 Goodlett Farms Pkwy, Ste 400
Memphis TN 38016 USA
Hunter Fan
Company
Abbildung 4 - Anschluss-Stellschrauben, Ansicht von unten
Commande murale de ventilateur
de plafond
Modèles de commande murale : 24758
Caractéristiques nominales : 240 V c.a., 1 A max.
Lisez et conservez ces instructions
MISES EN GARDE ! Risque de
secousse électrique
Pour éviter une secousse électrique possible, avant de câbler
le ventilateur, coupez l’électricité à boîte de raccordement et à
l’emplacement associé avec l’interrupteur mural.
Conformité
• Cet équipement a été testé et est conforme à : IEC 60669-1- 1998 et
EN 60669-1-1999.
• Tout le câblage doit se faire selon les codes électriques locaux et
nationaux en vigueur. Si vous n’êtes pas familiarisé avec le câblage
électrique, nous vous conseillons de faire appel à un électricien de
métier.
• Pour éviter la surchauffe et des dégâts possibles à d’autres appareils,
ne l’installez pas pour contrôler une prise de courant, une lampe
uorescente, un appareil avec moteur ou alimenté par transformateur.
Employez-la uniquement pour commander un ventilateur de plafond à
pales et un luminaire à lampes.
• N’employez cette commande que pour des ventilateurs de plafond
réversibles d’une puissance nominale de 1 A ou moins.
N’employez pas cette commande pour des moteurs à enroulement
à court circuit ou non-réversibles. Il est déconseillé de l’employer
pour le ventilateur Hunter Original
®
.
Choix de plaque avant
Vous avez le choix entre deux plaques avant différentes. Pour retirer la
plaque avant, tenez-la à deux mains par les bords et poussez fermement
avec les pouces sur les côtés opposés de l’interrupteur interne jusqu’à
ce qu’il sorte de la plaque avant. Voir gure 1.
Poussez ici
Poussez ici
Figure 1 - Retrait de l’interrupteur de la plaque avant
Pour insérer l’interrupteur, centrez-le dans l’ouverture de la nouvelle
plaque avant et poussez dessus jusqu’à ce que les six languettes de
retenue se soient mises en place avec un bruit sec et que l’interrupteur
est au même niveau que la plaque avant. Voir gure 2.
Figure 3 - Emplacement des bornes
Plaque avant carrée
de rechange
Alimentation
Ventilateur
Figure 5 - Interrupteur de vitesse
Commande
de vitesse du
ventilateur
Arrêt
Haute
Moyenne
Basse
Symptôme
Rien ne marche
Causes possibles
Le courant est coupé. Remplacez le fusible.
Réenclenchez l’électricité
Placez l’interrupteur mural
sous tension.
Vériez les connexions
de câblage.
La chaînette du ventilateur
n’est pas en position HAUTE.
La chaînette du ventilateur
n’est pas en position de
marche.
Solution
Coupez l’électricité à
l’interrupteur mural ou au
tableau principal. Réglez la
vitesse du ventilateur sur
HAUTE.
Dépannage
Vis (l de ventilateur)
Ventilateur
Vis (V c.a., non visible)
Alimentation
Figure 2 - Insertion de l’interrupteur dans la plaque avant
Câblage
Déconnectez l’électricité du ventilateur de plafond au tableau électrique
principal Enlevez le fusible ou placez le disjoncteur en position HORS
TENSION. Coupez l’électricité à l’interrupteur mural.
Les bouts des ls doivent être droits et ne pas être dénudés sur plus de
13 mm. Avant d’insérer les ls dans les bornes, desserrez chaque vis de
borne pour permettre une insertion facile du l, sans retirer complètement
la vis. Voir gures 3 et 4.
Connectez le l d’alimentation à la borne avec l’icône VAC (c.a.) et
serrez bien la vis.
Connectez le l du ventilateur à l’icône avec un ventilateur , et serrez
bien les vis. Référez-vous aux gures 3 et 4.
Veillez à ce qu’il n’y ait pas l dénudé exposé aux points de connexion.
Poussez les ls dans la boîte de raccordement et montez la commande
murale à la boîte de raccordent à l’aide des deux vis fournies.
Commande de ventilateur
Commande de vitesse du ventilateur
Pour commander le ventilateur, réglez le cadran de contrôle de vitesse
dans la position désirée comme indiqué à la gure 5. Les positions sont,
de gauche à droite, arrêt, haute, moyenne et basse. La chaînette de
commande de vitesse sur le ventilateur-même doit être réglée sur HAUTE
pour que la commande murale fonctionne correctement.
24758
© 2015 Hunter Fan Company 41613-06 01/23/15
Hunter Fan Company
7130 Goodlett Farms Pkwy, Ste 400
Memphis TN 38016 USA
Hunter Fan
Company
Figure 4 - Vis de bornes, vue du bas
Comando a muro per ventilatore
Modelli di comando a muro: 24758
Potenza nominale: 240 VAC, 1A max
Leggere e conservare queste istruzioni
AVVERTENZA Rischio di scosse
elettriche
Per evitare eventuali scosse elettriche, prima di collegare il
ventilatore scollegare la corrente spegnendo l’alimentazione di
rete sia nella scatola elettrica che nel relativo interruttore a muro.
Conformità
• Questo apparecchio è stato testato ed è conforme a: IEC 60669-1-
1998 e EN 60669-1-1999.
• Tutti gli allacciamenti devono essere conformi ai regolamenti locali e
nazionali. Se non si è pratici di allacciamenti rivolgersi ad un elettricista
qualicato.
• Per evitare surriscaldamenti ed eventuali danni ad altri apparecchi non
effettuare l’installazione per comandare portalampada a uorescenza
con presa, apparecchi motorizzati né apparecchi alimentati da un
trasformatore.
Utilizzare l’apparecchio solo per comandare un ventilatore da softto
ad una pala.
Da usare solo con ventilatori da softto reversibili con potenza
nominale pari o inferiore a 1,0 A.
Non utilizzare con motori con espansione polare spaccata o non
reversibili. Non consigliato per l’uso con Hunter Original
®
.
Selezione della mascherina
Sono disponibili due modelli di mascherine da muro. Per togliere la
mascherina tenere il gruppo mascherina per i bordi con le due mani e
premere forte con i pollici sui lati opposti del gruppo interruttore interno
nché non fuoriesce dalla mascherina. Vedere la gura 1.
Premere qui
Figura 1 - Rimozione del gruppo interruttore dalla mascherina
Per inserire il gruppo interruttore centrarlo nell’apertura della mascherina
di tipo alternativo e premerlo su di essa nché le sei linguette di ssaggio
non si sono inserite in posizione ed il gruppo interruttore non è a lo con
la mascherina. Vedere la gura 2.
Figura 3 - Posizioni dei morsetti
Mascherina quadrata alternativa
Alimentazione
Ventilatore
Luce
Figura 5 - Comando velocità
Comando
velocità
ventilatore
Spento
Alto
Medio
Basso
Sintomo
Nessuna funzione
operativa.
Cause probabili
Non è stata ripristinata
l’alimentazione di rete.
Sostituire il fusibile.
Accendere (ON)
l’alimentazione di rete.
Accendere (ON) l’interruttore
a muro.
Vericare il cablaggio.
Catenella del ventilatore non
impostata su HIGH (ALTO).
Cablaggio di comando errato.
Soluzione
Spegnere (OFF)
l’alimentazione
sull’interruttore a muro o
l’alimentazione di rete.
Impostare il ventilatore
sulla velocità HIGH (ALTO).
Ricerca guasti
Vite di arresto (lo del
ventilatore)
Ventilatore
Vite di arresto
(VAC, non visibile)
Alimentazione
Figura 2 - Inserimento del gruppo interruttore nella mascherina
Cablaggio
Scollegare l’alimentazione del ventilatore da softto sul quadro elettrico
principale. Togliere il fusibile o spostare l’interruttore in posizione OFF.
Spegnere l’interruttore a muro.
Le estremità dei li conduttori devono essere diritte e non si devono
togliere più di 13 mm di isolante. Prima di inserire i li nei morsetti allentare
le viti di arresto di ciascun morsetto quanto basta per inserire facilmente il
lo conduttore senza togliere completamente le viti. Vedere le gure 3 e 4.
Collegare il lo di alimentazione al morsetto contrassegnato con l’icona
VAC e stringere bene le viti di arresto.
Collegare il lo del ventilatore al morsetto con l’icona del ventilatore
stringendo bene le viti di arresto dei morsetti. Fare riferimento alle gure
3 e 4.
Assicurarsi che non ci siano li scoperti nei punti di connessione. Spingere
i li nella scatola elettrica e montare il gruppo di comando a muro nella
scatola elettrica a muro con le due viti fornite in dotazione.
Premere qui
Comando ventilatore
Comando velocità ventilatore
Per comandare il ventilatore mettere il quadrante di comando della
velocità del ventilatore nella posizione desiderata come indicato in gura
5. Le posizioni, da sinistra a destra, sono spento, alto, medio e basso.
La catenella di comando della velocità che si trova sul ventilatore deve
essere impostata su alto perché il comando funzioni adeguatamente.
5
24758
© 2015 Hunter Fan Company 41613-07 01/23/15
Hunter Fan Company
7130 Goodlett Farms Pkwy, Ste 400
Memphis TN 38016 USA
Hunter Fan
Company
Figura 4 - Viti di arresto morsetti, vista dal basso
Tavan Fanı Duvar Kontrolü
Duvar Kontrol Modelleri: 24758
Güç: 240 VAC, 1A Maksimum
Bu Talimatları Okuyun ve Saklayın
UYARI: Elektrik çarpması riski
Olası bir elektrik çarpmasından kaçınmak için fanınızın kablo
bağlantılarını yapmadan önce ana gücü kapatarak hem çıkış
kutusuna ve ilgili duvardaki elektrik düğmesine giden gücü kesin.
Uyma
Bu ekipman test edilmiştir ve aşağıdaki standartlara uygundur: IEC
60669-1-1998 ve EN 60669-1-1999.
Tüm kablolama ulusal ve yerel elektrik standartlarına uygun
olmalıdır. Kablolama hakkında bilginiz yoksa kaliye bir elektrik
teknisyeni kullanın.
Avusturya’daki yerel yasalar uyarınca, ulusal ve yerel
standartlara göre bu kontrolün monte edilmesi için bir kaliye
elektrik teknisyeni gereklidir.
Aşırı ısınmadan ve ekipmanın olası hasarından kaçınmak için
kontrol sistemini bir prize, oresan lamba düzeneğine, motorla
çalışan bir cihaza veya trafoyla beslenen bir cihaza monte etmeyin.
Sadece kanatlı tavan fanının donanımını kontrol etmek için kullanın.
Sadece elektrikle yönü tersine çevrilebilir 1.0 Amper veya daha az
gücündeki tavan fanlarla.
Gölge kutuplu veya elektrikle yönü tersine çevrilemeyen
motorlarla birlikte kullanılamaz. Hunter Original
®
ile birlikte
kullanılması önerilmez.
Ön Yüz Seçimi
İki tip duvar ön yüzü verilmektedir. Ön yüzü sökmek için her iki elinizle
ön yüz düzeneğini tutun ve ön yüzden çıkıncaya kadar iç anahtarı karşıt
yönlerini başparmaklarınızla sıkıca bastırın. Şekil 1’e bakın.
Buraya Basın
Buraya Basın
Şekil 1 - Anahtar Düzeneğinin Ön Yüzden Sökülmesi
Anahtar düzeneğini sokmak için, yön değiştirmeli tip kare ön yüze
merkezleyin ve tüm altı tutma çıkıntısı yerlerine geçinceye ve anahtar
düzeneği ön yüze sıfır oluncaya kadar ön yüze doğru bastırın. Şekil
2’ye bakın.
Şekil 3 - Terminal Konumları
© 2015 Hunter Fan Company 41613-15 01/23/15
Yön Değiştirmeli Kare Ön Yüz
Hunter Fan Company
7130 Goodlett Farms Pkwy, Ste 400
Memphis TN 38016 USA
Şekil 4 - Terminal Ayar Vidaları, alttan görünüm.
Fan Hız Kontrol
Fanı kontrol etmek için, Şekil 5’te gösterildiği gibi fan hızı kontrol kadranını
istenen konuma ayarlayın. Soldan sağa konumlar: kapalı, yüksek, orta ve
düşük. Fanın kendi üzerindeki hız kontrol çekme zinciri, duvar kontrolünün
doğru çalışması için yüksek konuma ayarlanmalıdır.
Şekil 5- Hız Kontrol
Fan Hız
Kontrol
Kapalı
Yüksek
Orta
Düşük
Semptom
Hiçbir şey
çalışmıyor.
Olası Nedenler
Ana Güç kaynağı yok. Sigortayı değiştirin. Ana
Güç Kaynağını Açın (ON).
Duvar Anahtarını açın (ON).
Kablo bağlantı noktalarını
kontrol ederek onaylayın.
Fan Çekme Zinciri
HIGH (yüksek) konuma
getirilmemiş.
Kablolamanın doğru olup
olmadığını kontrol edin.
Çözüm
Duvar anahtarında veya
ana güç kaynağında
gücü KESİN. Fanı HIGH
(yüksek) hıza ayarlayın.
Sorun Giderme
Ayar vidası (Fan Kablosu)
Fan
Ayar vidası
(VAC, görülemez)
Güç
Şekil 2 - Anahtar Düzeneğinin Ön Yüze Sokulması
Kablolama
Tavan fanının gücünü ana elektrik panelinden kesin. Sigortayı çıkartın
veya devre kesiciyi OFF (kapalı) konuma getirin. Duvar anahtarını kapatın.
Kablo uçları düz olmalıdır ve uçlardan 13 mm’den fazla izolasyon
sökülmemelidir. Kabloları terminallere sokmadan önce, ayar vidasını
tamamen sökmeden kablo ucunun kolayca sokulmasını sağlamak için
her bir terminaldeki terminal ayar vidalarını gevşetin. Şekil 2 ve 4’e bakın.
Güç kablosunu VAC simgesi ile işaretlenmiş terminale bağlayın ve
ayar vidasını iyice sıkın.
Fan kablosunu Fan simgesi ile işaretlenmiş terminale ve ayar vidalarını
iyice sıkın. Bilgi için Şekil 3 ve 4’e bakın.
Bağlantı noktalarında açıkta çıplak kablo olmadığından emin olun.
Kabloları elektrik kutusuna itin ve verilmiş iki vidayı kullanarak duvar
kontrol düzeneğini duvar elektrik kutusuna monte edin.
Fan Kontrol
Güç
Fan
5
24758
Hunter Fan
Company
Επιτοίχια μονάδα ελέγχου για
ανεμιστήρα οροφής
Μοντέλα επιτοίχιας μονάδας ελέγχου: 24758
Χαρακτηριστικά: 240 VAC, 1 A μέγ.
Διαβάστε και φυλάξτε αυτές τις οδηγίες
ΠΡΟΕΙΔΟΠΟΙΗΣΗ: κίνδυνος
ηλεκτροπληξίας
Προκειμένου να αποφύγετε πιθανή ηλεκτροπληξία, διακόψτε
πριν την καλωδίωση του ανεμιστήρα την ηλεκτρική τροφοδοσία,
θέτοντας τους κεντρικούς διακόπτες τροφοδοσίας τόσο προς τον
διανεμητή όσο και προς τον αντίστοιχο επιτοίχιο διακόπτη στη θέση
απενεργοποίησης.
Compliance
Αυτή η συσκευή έχει ελεγχθεί και συμμορφώνεται με τα πρότυπα:
IEC 60669-1-1998 και EN 60669-1-1999.
Η καλωδίωση θα πρέπει να είναι εξ ολοκλήρου σε συμφωνία με τους
εθνικούς και τοπικούς κώδικες. Εάν δεν διαθέτετε εξοικείωση με την
καλωδίωση, θα πρέπει να απευθυνθείτε σε ειδικευμένο ηλεκτρολόγο.
Στην Αυστραλία, οι εθνικοί νόμοι απαιτούν αυτή η μονάδα ελέγχου
να εγκατασταθεί από εκπαιδευμένο ηλεκτρολόγο, σύμφωνα με τους
εθνικούς και τοπικούς κανονισμούς.
Για να αποφευχθεί η υπερθέρμανση και πιθανή βλάβη άλλου
εξοπλισμού, μην συνδέεται στη μονάδα ελέγχου ρευματοδότη,
συσκευή φθορίζοντα φωτισμού, συσκευή με κινητήρα ή συσκευή
που τροφοδοτείται μέσω μετασχηματιστή.
Χρησιμοποιήστε την αποκλειστικά για τον έλεγχο ενός ανεμιστήρα
οροφής με πτερύγια.
Για χρήση μόνο με ηλεκτρικά αντιστρέψιμους ανεμιστήρες οροφής
με ονομαστική ένταση ρεύματος 1,0 Α ή μικρότερη.
Όχι για χρήση με κινητήρες σχιστού πόλου ή μη αντιστρέψιμους.
Δεν συνιστάται για χρήση με τον Hunter Original
®
.
Επιλογή πρόσοψης
Παρέχονται δύο προσόψεις διαφορετικού στυλ. Για να αφαιρέσετε την
πρόσοψη, κρατήστε τη διάταξη της πρόσοψης από τις άκρες με τα δύο
χέρια και πιέστε σταθερά με τους αντίχειρες στις αντίθετες πλευρές
της εσωτερικής διάταξης του διακόπτη, έως ότου ελευθερωθεί από την
πρόσοψη. Βλ. εικόνα 1.
Πιέστε εδώ
Πιέστε εδώ
Εικόνα 1 - Αφαίρεση της διάταξης του διακόπτη από την πρόσοψη.
Για να εισαγάγετε τη διάταξη διακόπτη, τοποθετήστε τη στο κέντρο του
ανοίγματος της εναλλακτικής πρόσοψης και πιέστε τη στην πρόσοψη,
έως ότου και τα έξι γλωσσίδια συγκράτησης να μανδαλώσουν στη θέση
τους και η διάταξη διακόπτη να εφαρμόσει στην πρόσοψη. Βλ. εικόνα 2.
Εικόνα 3 - Θέσεις ακροδεκτών
© 2015 Hunter Fan Company 41613-16 01/23/15
Εναλλακτική τετράγωνη πρόσοψη
Hunter Fan Company
7130 Goodlett Farms Pkwy, Ste 400
Memphis TN 38016 USA
Εικόνα 4 - Ακέφαλοι κοχλίες ακροδεκτών, όψη από τα κάτω
Έλεγχος ανεμιστήρα
Έλεγχος ταχύτητας ανεμιστήρα
Για τον έλεγχο του ανεμιστήρα, θέστε τον επιλογέα ταχύτητας ανεμιστήρα
στην επιθυμητή θέση, όπως φαίνεται στην εικόνα 5. Οι θέσεις είναι
απενεργοποίηση, υψηλή, μέση και χαμηλή, από αριστερά προς τα δεξιά.
Προκειμένου ο επιτοίχιος έλεγχος να λειτουργεί σωστά, πρέπει η αλυσίδα
ελέγχου της ταχύτητας στον ίδιο τον ανεμιστήρα να ρυθμιστεί στη θέση
για υψηλή ταχύτητα.
Εικόνα 5 - Έλεγχος ταχύτητας
Έλεγχος ταχύτητας
ανεμιστήρα
Απενεργοποίηση
Υψηλή
Μέση
Χαμηλή
Σύμπτωμα
Καμία λειτουργία
δεν ενεργοποιείται.
Πιθανές αιτίες
Δεν έχει αποκατασταθεί η
κεντρική τροφοδοσία.
Επανατοποθετήστε την
ασφάλεια. Ενεργοποιήστε
την κεντρική τροφοδοσία.
Θέστε τον επιτοίχιο
διακόπτη στη θέση
ενεργοποίησης.
Επιβεβαιώστε τις
συνδέσεις καλωδίωσης.
Η αλυσίδα του ανεμιστήρα
δεν είναι ρυθμισμένη στη
θέση για υψηλή ταχύτητα.
Λανθασμένη καλωδίωση της
διάταξης ελέγχου.
Λύση
Θέστε τον επιτοίχιο
διακόπτη στη θέση
απενεργοποίησης ή
διακόψτε την τροφοδοσία
από τον κεντρικό πίνακα.
Θέστε τον ανεμιστήρα στη
θέση για υψηλή ταχύτητα.
Αντιμετώπιση προβλημάτων
Ακέφαλος κοχλίας
(καλώδιο ανεμιστήρα)
Ανεμιστήρας
Ακέφαλος κοχλίας
(τροφοδοσία, μη ορατό)
Ισχύς
Εικόνα 2 - Εισαγωγή της διάταξης του διακόπτη στην πρόσοψη
Καλωδίωση
Αποσυνδέστε την ηλεκτρική τροφοδοσία του ανεμιστήρα οροφής στον
κεντρικό ηλεκτρικό πίνακα.. Αφαιρέστε την ασφάλεια ή θέστε τον διακόπτη
κυκλώματος στη θέση απενεργοποίησης. Θέστε τον επιτοίχιο διακόπτη
στη θέση απενεργοποίησης.
Τα άκρα των αγωγών πρέπει να είναι ίσια και να μην τους έχει αφαιρεθεί
περισσότερο από 13 mm μόνωσης. Πριν να εισαγάγετε τα καλώδια στους
ακροδέκτες, ξεβιδώστε τον ακέφαλο κοχλία κάθε ακροδέκτη αρκετά, ώστε
να είναι δυνατή η εύκολη εισαγωγή του αγωγού του καλωδίου, χωρίς να
αφαιρέσετε τελείως τον ακέφαλο κοχλία. Βλ. εικόνες 3 και 4.
Συνδέστε το καλώδιο τροφοδοσίας στον ακροδέκτη που είναι σημειωμένος
με το εικονίδιο τροφοδοσίας και σφίξτε καλά τον ακέφαλο κοχλία.
Συνδέστε το καλώδιο του ανεμιστήρα στον ακροδέκτη με το εικονίδιο
ανεμιστήρα στον ακροδέκτη με το εικονίδιο,σφίγγοντας καλά τους
ακέφαλους κοχλίες των ακροδεκτών. Βλ. εικόνες 3 και 4 για αναφορά.
Βεβαιωθείτε ότι δεν υπάρχουν εκτεθειμένα γυμνά καλώδια στα σημεία
σύνδεσης. Σπρώξτε τα καλώδια στο κουτί συνδέσεων και αναρτήστε τη
διάταξη της επιτοίχιας μονάδας ελέγχου στο επιτοίχιο κουτί συνδέσεων
χρησιμοποιώντας τους δύο κοχλίες που παρέχονται.
Ισχύς
Ανεμιστήρας
24758
Hunter Fan
Company
Kontrol Dinding untuk Kipas
Langit-langit
Model Kontrol Dinding: 24758
Rating: 240 VAC, 1A Maks
Bacalah dan Simpan Petunjuk ini
PERINGATAN: Risiko sengatan listrik
Untuk menghindari kemungkinan sengatan listrik, sebelum
memasang kabel kipas, putuskan aliran listrik dengan mematikan
aliran listrik PLN ke stopkontak dan ke lokasi sakelar dinding yang
terkait.
Compliance
Peralatan ini telah diuji dan mematuhi: IEC 60669-1-1998 dan EN
60669-1-1999.
Semua pengawatan harus sesuai dengan peraturan kelistrikan
nasional dan lokal. Jika Anda tidak terlalu mengerti pengawatan,
Anda harus meminta bantuan teknisi listrik yang berkualikasi.
Di Australia, undang-undang nasional mewajibkan agar pemasangan
kontrol ini dilakukan oleh teknisi listrik yang berkualikasi sesuai
dengan peraturan nasional dan lokal.
• Untuk menghindari panas berlebihan dan kemungkinan kerusakan
pada peralatan lain, jangan memasang perangkat ini untuk
mengontrol stopkontak, kstur lampu uoresen, perkakas yang
dioperasikan dengan motor, atau perkakas yang dipasok dengan
trafo.
Gunakan hanya untuk mengontrol satu kipas langit-langit bilah-
dayung dan.
Untuk digunakan hanya dengan kipas langit-langit yang secara
kelistrikan dapat dibalik dengan rating 1,0 A atau kurang.
Tidak untuk digunakan dengan motor kutub-bayangan atau motor
yang tidak dapat dibalik (satu arah putaran). Tidak disarankan
untuk digunakan dengan Hunter Original
®
.
Pemilihan Pelat muka
Dua model pelat muka dinding disediakan. Untuk melepaskan pelat muka,
pegang rangkaian pelat muka pada tepi-tepinya dengan kedua tangan
dan tekan kuat-kuat dengan ibu jari pada sisi yang berseberangan dari
rangkaian sakelar dalam sampai menceklek keluar dari pelat muka.
Lihat gambar 1.
Tekan di Sini
Tekan di Sini
Gambar 1 - Melepaskan Rangkaian Sakelar dari Pelat Muka.
Untuk memasukkan rangkaian sakelar, tengahkan rangkaian pada bukaan
pelat muka model alternatif dan tekan masuk ke dalam pelat muka sampai
keenam tab penahannya mengklik di tempatnya, dan rangkaian sakelar
rata dengan pelat muka. Lihat Gambar 2.
Gambar 3 - Lokasi Terminal
© 2015 Hunter Fan Company 41613-17 01/23/15
Pelat Muka Alternatif Persegi
Hunter Fan Company
7130 Goodlett Farms Pkwy, Ste 400
Memphis TN 38016 USA
Gambar 4 - Sekrup Pengikat Terminal, dilihat dari bawah
Kontrol Kipas
Kontrol Kecepatan Kipas
Untuk mengontrol kipas, putar tombol kontrol kecepatan kipas ke posisi
yang diinginkan seperti ditunjukkan dalam Gambar 5. Posisinya adalah
Mati, Tinggi, Sedang, dan Rendah dari kiri ke kanan. Rantai-tarik kontrol
kecepatan pada kipas itu sendiri harus diatur ke Tinggi agar kontrol dinding
berfungsi dengan benar.
Gambar 5 - Kontrol Kecepatan
Kontrol
Kecepatan Kipas
Mati
Tinggi
Sedang
Rendah
Gejala
Tidak ada fungsi
yang bekerja.
Kemungkinan
Penyebab
Listrik Utama belum
dinyalakan kembali.
Ganti sekering. Hidupkan
aliran listrik PLN.
Hidupkan sakelar dinding.
Periksa kembali
sambungan pengawatan.
Rantai-tarik kipas tidak diatur
ke TINGGI.
Pengawatan kontrol salah.
Solusi
Matikan aliran listrik pada
sakelar dinding atau aliran
listrik PLN. Atur kipas ke
kecepatan TINGGI.
Pemecahan Masalah
Sekrup Pengikat
(Kabel Kipas)
Kipas
Sekrup Pengikat
(VAC, tidak terlihat)
Listrik
Gambar 2 - Memasukkan Rangkaian Sakelar ke Pelat Muka
Pengawatan
Matikan aliran listrik ke kipas langit-langit pada panel listrik utama
Lepaskan sekering atau geser pemutus arus ke posisi OFF. Matikan
sakelar dinding.
Ujung kawat kabel harus lurus dan panjang isolasi yang dikupas tidak lebih
dari 13 mm. Sebelum memasukkan kawat ke terminal, kendurkan sekrup
pengikat terminal pada setiap terminal secukupnya untuk memungkinkan
kawat kabel masuk dengan mudah, tanpa harus melepas sekrup pengikat
sepenuhnya. Lihat gambar 3 dan 4.
Sambungkan kabel listrik ke terminal yang ditandai dengan ikon VAC
dan kencangkan sekrup pengikatnya kuat-kuat.
Sambungkan kabel Kipas ke terminal dengan ikon Kipas , dan
kemudian kencangkan sekrup pengikat terminalnya kuat-kuat. Lihat
Gambar 3 dan 4 untuk acuannya.
Pastikan tidak ada kabel telanjang yang terbuka pada titik penyambungan.
Dorong kabel masuk ke kotak listrik dan pasang rangkaian kontrol dinding
ke kotak listrik dinding menggunakan kedua sekrup yang disediakan.
Listrik
Kipas
5
24758
Hunter Fan
Company

Transcripción de documentos

Hunter Fan Company To insert the switch assembly, center it in the opening of the alternate style faceplate and press it into the faceplate until all six retaining tabs have snapped into place, and the switch assembly is flush with the faceplate. See Figure 2. Fan Control Fan Speed Control To control the fan, set the fan speed control dial to the desired position as shown in Figure 5. Positions are Off, High, Medium and Low from left to right. The speed control pull chain on the fan itself must be set to High for the wall control to function properly. Wall Control for Ceiling Fan Wall Control Models: 24758 Ratings: 240 VAC, 1A Max Off Read and Save these Instructions WARNING! Risk of Electrical Shock To avoid possible electrical shock, before wiring fan, disconnect power by turning off the power mains both to the outlet box and to its associated wall switch location. Compliance • This equipment has been tested and complies with: IEC 60669-1-1998 and EN 60669-1-1999. High Medium Figure 2 - Switch Assembly insertion in Faceplate Low Wiring • All wiring must be in accordance with national and local electrical codes. If you are unfamiliar with wiring, you should use a qualified electrician. The ends of the wire leads should be straight and have no more than 13 mm of insulation removed. Before inserting wires into terminals, loosen the terminal setscrews on each terminal enough to allow the easy insertion of the wire lead, without removing the setscrew completely. See figures 3 and 4. • In Australia, national laws require a qualified electrician to install this control in accordance with national and local codes. Connect the power wire to the terminal marked with the VAC tighten the setscrew firmly. • To avoid over heating and possible damage to other equipment, do not install to control a receptacle, fluorescent light fixture, motor operated appliance, or transformer-supplied appliance. Connect the Fan wire to the terminal with the Fan icon. Tighten the terminal setscrews firmly. See Figures 3 and 4 for reference. Use only to control one ceiling fan. For use only with electrically reversible ceiling fans rated at 1.0 A or less. Fan Speed Control Disconnect the power to the ceiling fan at the main electric panel. Remove fuse or move circuit breaker to the OFF position. Turn off wall switch. icon and Figure 5 - Speed Control Be sure no bare wire is exposed at the connection points. Push the wires into the electrical box and mount the wall control assembly to the wall electrical box using the two screws provided. Not for use with shaded-pole or nonreversible motors. Not recommended for use with the Hunter Original®. Power Faceplate Selection Two styles of wall faceplates are provided. To remove the faceplate, hold the faceplate assembly by the edges in both hands and press firmly with your thumbs on opposite sides of the inner switch assembly until it snaps out of the faceplate. See figure 1. Troubleshooting Symptom Possible Causes Solution No functions operate. Main Power not restored. Replace fuse. Turn ON power mains. Turn ON wall switch. Fan pull chain not set to HIGH. Turn OFF power at wall switch or power mains. Set fan to HIGH speed. Control wiring incorrect. Verify wiring connections. 24758 5 Fan Press Here Press Here Figure 3 - Terminal Locations Setscrew (Fan Wire) Setscrew (VAC, not visible) Fan Alternate Square Faceplate Hunter Fan Company Power 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA Figure 1 - Removing Switch Assembly from Faceplate. Figure 4 - Terminal Setscrews, view from bottom © 2015 Hunter Fan Company 44301-01 01/23/15 Hunter Fan Company Para introducir el conjunto del interruptor, céntrelo en la abertura de la placa frontal alternativa y presiónelo dentro de la placa hasta que las seis lengüetas de retención hayan entrado a presión en su lugar, y cuando el conjunto del interruptor esté a nivel con la placa. Vea la Figura 2. Control del ventilador Control de velocidad del ventilador Para controlar el ventilador, fije el dial de control de velocidad del ventilador en la posición deseada, como se muestra en la Figura 5. Las posiciones son Apagado, Alta, Media y Baja de izquierda a derecha. La cadena de control de velocidad en el mismo ventilador debe estar fijada en Alta para que el control de pared funcione correctamente. Control de pared para ventilador de techo Modelos de control de pared: 24758 Capacidad: 240 VAC, 1 A máx. Apagada Alta Lea y guarde estas instrucciones ¡ADVERTENCIA! Riesgo de choque eléctrico Para evitar un choque eléctrico, antes de cablear el ventilador, desconecte la energía de la red apagando la alimentación principal a la caja de salida y a su interruptor de pared asociado. Cumplimiento • Este equipo se ha probado y cumple con las normas: IEC 60669-1-1998 EN 60669-1-1999. • Todo cableado debe realizarse de acuerdo con los códigos eléctricos nacionales y locales. Si no está familiarizado con el cableado, debe emplear un electricista calificado. • Para evitar el recalentamiento y daño a otros equipos, no realice la instalación para controlar un receptáculo, artefacto de iluminación fluorescente, aparato operado por motor o alimentado por transformador. Úselo sólo para controlar un ventilador de techo con hoja de paleta. Cableado Baja Desconecte la alimentación de energía al ventilador de techo. Los extremos de los alambres deben estar rectos y no tener más de 13 mm de aislamiento retirado. Antes de introducir los alambres en los terminales, afloje los tornillos de ajuste de los terminales lo suficiente para permitir la fácil introducción de los alambres, pero sin retirar los tornillos por completo. Vea las Figuras 3 y 4. Conecte el alambre de alimentación al terminal marcado con el icono VAC y apriete firmemente su tornillo de ajuste. Asegúrese de que no haya alambres pelados visibles en los puntos de conexión. Empuje los alambres dentro de la caja eléctrica y monte el conjunto del control de pared en la caja usando los dos tornillos suministrados. Localización de fallas Alimentación Selección de placa frontal Síntoma Causas posibles Solución No opera ninguna función. La alimentación principal no se ha restaurado. Reemplace el fusible. Encienda el suministro principal de la red. Encienda el interruptor de pared. La cadena del ventilador no está fijada en HIGH (alta) Apague la alimentación en el interruptor de pared o en el suministro principal de la red. Fije el ventilador en velocidad HIGH (alta) Cableado de control incorrecto. Verifique las conexiones del cableado. 24758 Ventilador Presione aquí Figura 5 - Control de velocidad Conecte al alambre del ventilador al terminal con el icono del ventilador y apriete firmemente los tornillos de ajuste. Vea las Figuras 3 y 4 como referencia. No debe usarse con motores de polo sombreado o no reversibles. No se recomienda su uso con el modelo Hunter Original®. Presione aquí Control de velocidad del ventilador Retire el fusible o mueva el interruptor automático a la posición OFF (desconectado) Apague el interruptor de pared. Sólo para uso con ventiladores de techo con inversión eléctrica de rotación, de 1.0 amperio o menos. Se proporcionan dos estilos de placas frontales. Para retirar la placa frontal, sostenga el conjunto de la placa por los bordes en ambas manos y presione firmemente con sus pulgares en los lados internos opuestos del conjunto del interruptor hasta que salga de la placa haciendo un clic. Vea la Figura 1. Media Figura 2 - Introducción del conjunto del interruptor en la placa frontal Figura 3 - Ubicación de los terminales Tornillo de ajuste (alambre del ventilador) Tornillo de ajuste (VAC, no visible) Ventilador Placa frontal cuadrada alternativa Figura 1 - Retiro del conjunto del interruptor de la placa frontal. Hunter Fan Company Alimentación Figura 4 - Tornillos de ajuste de los terminales, vista desde la parte inferior 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA © 2015 Hunter Fan Company 41613-03 01/23/15 Hunter Fan Company Um den Schaltersatz einzubauen, zentrieren Sie ihn in der Öffnung der alternativen Blende und drücken Sie ihn in die Blende hinein bis alle sechs Sicherungsklappen eingeschnappt sind und der Schaltersatz mit der Blende bündig ist. Siehe Abbildung 2. Ventilatoren-Regler Ventilatoren-Geschwindigkeitsregler Zur Betätigung des Ventilators stellen Sie den Geschwindigkeitsregler auf die gewünschte Einstellung wie in Abbildung 5 gezeigt. Von links nach rechts gibt es die Einstellungen Aus, Hoch, Mittel, Niedrig. Die Zugkette zur Geschwindigkeitsregulierung am Ventilator selbst muss auf Hoch gestellt werden, damit der Wandregler richtig funktionieren kann. Wandregler für Deckenventilator Wandreglermodelle: 24757 Einstufung: 240 VAC, 1A Max Aus Lesen und bewahren Sie diese Hinweise gut auf WARNUNG! Stromschlaggefahr Zur Vermeidung eines Stromschlages, stellen Sie vor dem Anschließen des Ventilators das Stromnetz zum Stecker und den dazu gehörigen Wandschalter ab. Einhaltung von Industrienormen • Dieses Gerät wurde getestet und entspricht: IEC 60669-1-1999 und EN 60669-1. • Jegliche Verkabelung muss nationalen und lokalen elektrischen Vorschriften folgen. Wenn Sie sich nicht mit Verkabelung auskennen, ziehen Sie einen qualifizierten Elektriker zu Rate. Hoch Abbildung 2 - Einfügen des Schaltersatzes in die Blende Mittel Verkabelung Niedrig Die Enden der Kabelleitungen sollten gerade sein und weniger als 13mm Insulierung sollte entfernt sein. Bevor Kabel angeschlossen werden, lösen Sie die Anschluss-Stellschrauben weit genug, sodass die Kabelleitung leicht einzuführen ist, ohne dass die Stellschraube komplett entfernt wird. Siehe Abbildung 3 und 4. Schließen Sie das Elektrokabel an den Anschluss mit dem Symbol VAC und ziehen Sie die Stellschraube fest an. • Zur Vermeidung von Überhitzung und möglicher Beschädigung anderer Geräte, nicht zur Bedienung von Steckdosen, Leuchtstofflampen, motorisierte oder transformatorbetriebene Geräte installieren. Schließen Sie das Ventilator-Kabel an den Anschluss an den Anschluss mit dem Symbol und ziehen Sie die Stellschrauben fest an. Siehe Abbildung 3 und 4. Nur zur Bedienung von Flügel-Deckenventilatoren. Gehen Sie sicher, dass nirgendwo blankes Kabel an den Verbindungspunkten ungeschützt ist. Stecken Sie die Kabel in die elektrische Box und schrauben Sie den Wandreglersatz an die elektrische Wanddose mit den zwei vorgesehenen Schrauben. Nur zum Gebrauch mit elektrisch umkehrbaren Deckenventilatoren, die mit 1,0A oder weniger eingestuft sind. Nicht zum Gebrauch mit Schaltpol- oder Einweg-Motoren. Nicht empfohlen im Gebrauch mit Hunter Original®. Auswahl der Blende Strom Beiliegend sind zwei Arten Blenden. Zum Wechseln der Blende, halten Sie die Blende mit beiden Händen an den Ecken und drücken Sie feste mit den Daumen an gegenüberliegenden Seiten auf den inneliegenden Schaltersatz bis er herausschnappt. Siehe Abbildung 1. VentilatorenGeschwindigkeitsregler Schalten Sie den Strom zum Deckenventilator an der Hauptschalttafel aus. Entnehmen Sie die Sicherung oder stellen sie den Haupttrennschalter auf AUS. Schalten Sie den Wandschalter ab. 24758 Abbildung 5 - Geschwindigkeitsregler Fehlersuche Merkmal Mögliche Ursachen Lösung Keine Funktion betriebsfähig Hauptschalter nicht wieder angestellt Sicherung ersetzen. Stromnetz ANschalten. Wandschalter anstellen. Zugkette des Ventilators nicht auf HOCH gestellt Strom zum Wandschalter oder Stromnetz ABschalten. Ventilatorgeschwindigkeit auf HOCH stellen. Reglerverkabelung falsch. Kabelverbindungen nachprüfen. Ventilator Hier drücken Hier drücken Abbildung 3 - Lage der Anschlüsse Stellschraube (Ventilatorkabel) Stellschraube (VAC, nicht sichtbar) Ventilator Alternative Blende, quadratisch Abbildung 1 - Wechseln der Blende Hunter Fan Company 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA Strom Abbildung 4 - Anschluss-Stellschrauben, Ansicht von unten © 2015 Hunter Fan Company 41613-04 01/23/15 Hunter Fan Company Pour insérer l’interrupteur, centrez-le dans l’ouverture de la nouvelle plaque avant et poussez dessus jusqu’à ce que les six languettes de retenue se soient mises en place avec un bruit sec et que l’interrupteur est au même niveau que la plaque avant. Voir figure 2. Commande de ventilateur Commande de vitesse du ventilateur Pour commander le ventilateur, réglez le cadran de contrôle de vitesse dans la position désirée comme indiqué à la figure 5. Les positions sont, de gauche à droite, arrêt, haute, moyenne et basse. La chaînette de commande de vitesse sur le ventilateur-même doit être réglée sur HAUTE pour que la commande murale fonctionne correctement. Commande murale de ventilateur de plafond Modèles de commande murale : 24758 Caractéristiques nominales : 240 V c.a., 1 A max. Lisez et conservez ces instructions MISES EN GARDE ! Risque de secousse électrique Pour éviter une secousse électrique possible, avant de câbler le ventilateur, coupez l’électricité à boîte de raccordement et à l’emplacement associé avec l’interrupteur mural. Conformité • Cet équipement a été testé et est conforme à : IEC 60669-1- 1998 et EN 60669-1-1999. • Tout le câblage doit se faire selon les codes électriques locaux et nationaux en vigueur. Si vous n’êtes pas familiarisé avec le câblage électrique, nous vous conseillons de faire appel à un électricien de métier. • Pour éviter la surchauffe et des dégâts possibles à d’autres appareils, ne l’installez pas pour contrôler une prise de courant, une lampe fluorescente, un appareil avec moteur ou alimenté par transformateur. Employez-la uniquement pour commander un ventilateur de plafond à pales et un luminaire à lampes. Arrêt Haute Figure 2 - Insertion de l’interrupteur dans la plaque avant Moyenne Câblage Basse Les bouts des fils doivent être droits et ne pas être dénudés sur plus de 13 mm. Avant d’insérer les fils dans les bornes, desserrez chaque vis de borne pour permettre une insertion facile du fil, sans retirer complètement la vis. Voir figures 3 et 4. Connectez le fil d’alimentation à la borne avec l’icône VAC (c.a.) serrez bien la vis. Connectez le fil du ventilateur à l’icône avec un ventilateur bien les vis. Référez-vous aux figures 3 et 4. et , et serrez Alimentation N’employez pas cette commande pour des moteurs à enroulement à court circuit ou non-réversibles. Il est déconseillé de l’employer pour le ventilateur Hunter Original®. 24758 Rien ne marche Ventilateur Poussez ici Dépannage Symptôme Causes possibles Solution Vous avez le choix entre deux plaques avant différentes. Pour retirer la plaque avant, tenez-la à deux mains par les bords et poussez fermement avec les pouces sur les côtés opposés de l’interrupteur interne jusqu’à ce qu’il sorte de la plaque avant. Voir figure 1. Poussez ici Figure 5 - Interrupteur de vitesse Veillez à ce qu’il n’y ait pas fil dénudé exposé aux points de connexion. Poussez les fils dans la boîte de raccordement et montez la commande murale à la boîte de raccordent à l’aide des deux vis fournies. • N’employez cette commande que pour des ventilateurs de plafond réversibles d’une puissance nominale de 1 A ou moins. Choix de plaque avant Commande de vitesse du ventilateur Déconnectez l’électricité du ventilateur de plafond au tableau électrique principal Enlevez le fusible ou placez le disjoncteur en position HORS TENSION. Coupez l’électricité à l’interrupteur mural. Figure 3 - Emplacement des bornes Le courant est coupé. Remplacez le fusible. Réenclenchez l’électricité Placez l’interrupteur mural sous tension. La chaînette du ventilateur n’est pas en position HAUTE. Coupez l’électricité à l’interrupteur mural ou au tableau principal. Réglez la vitesse du ventilateur sur HAUTE. La chaînette du ventilateur n’est pas en position de marche. Vérifiez les connexions de câblage. Vis (fil de ventilateur) Vis (V c.a., non visible) Ventilateur Figure 1 - Retrait de l’interrupteur de la plaque avant Hunter Fan Company Alimentation Plaque avant carrée de rechange Figure 4 - Vis de bornes, vue du bas 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA © 2015 Hunter Fan Company 41613-06 01/23/15 Hunter Fan Company Per inserire il gruppo interruttore centrarlo nell’apertura della mascherina di tipo alternativo e premerlo su di essa finché le sei linguette di fissaggio non si sono inserite in posizione ed il gruppo interruttore non è a filo con la mascherina. Vedere la figura 2. Comando ventilatore Comando velocità ventilatore Per comandare il ventilatore mettere il quadrante di comando della velocità del ventilatore nella posizione desiderata come indicato in figura 5. Le posizioni, da sinistra a destra, sono spento, alto, medio e basso. La catenella di comando della velocità che si trova sul ventilatore deve essere impostata su alto perché il comando funzioni adeguatamente. Comando a muro per ventilatore Modelli di comando a muro: 24758 Potenza nominale: 240 VAC, 1A max Leggere e conservare queste istruzioni AVVERTENZA Rischio di scosse elettriche Per evitare eventuali scosse elettriche, prima di collegare il ventilatore scollegare la corrente spegnendo l’alimentazione di rete sia nella scatola elettrica che nel relativo interruttore a muro. Conformità • Questo apparecchio è stato testato ed è conforme a: IEC 60669-11998 e EN 60669-1-1999. • Tutti gli allacciamenti devono essere conformi ai regolamenti locali e nazionali. Se non si è pratici di allacciamenti rivolgersi ad un elettricista qualificato. • Per evitare surriscaldamenti ed eventuali danni ad altri apparecchi non effettuare l’installazione per comandare portalampada a fluorescenza con presa, apparecchi motorizzati né apparecchi alimentati da un trasformatore. Utilizzare l’apparecchio solo per comandare un ventilatore da soffitto ad una pala. Spento Figura 2 - Inserimento del gruppo interruttore nella mascherina Alto Cablaggio Medio Scollegare l’alimentazione del ventilatore da soffitto sul quadro elettrico principale. Togliere il fusibile o spostare l’interruttore in posizione OFF. Spegnere l’interruttore a muro. Basso Comando velocità ventilatore Le estremità dei fili conduttori devono essere diritte e non si devono togliere più di 13 mm di isolante. Prima di inserire i fili nei morsetti allentare le viti di arresto di ciascun morsetto quanto basta per inserire facilmente il filo conduttore senza togliere completamente le viti. Vedere le figure 3 e 4. Collegare il filo di alimentazione al morsetto contrassegnato con l’icona VAC e stringere bene le viti di arresto. Collegare il filo del ventilatore al morsetto con l’icona del ventilatore stringendo bene le viti di arresto dei morsetti. Fare riferimento alle figure 3 e 4. Figura 5 - Comando velocità Assicurarsi che non ci siano fili scoperti nei punti di connessione. Spingere i fili nella scatola elettrica e montare il gruppo di comando a muro nella scatola elettrica a muro con le due viti fornite in dotazione. Da usare solo con ventilatori da soffitto reversibili con potenza nominale pari o inferiore a 1,0 A. Non utilizzare con motori con espansione polare spaccata o non reversibili. Non consigliato per l’uso con Hunter Original®. Alimentazione Selezione della mascherina Sono disponibili due modelli di mascherine da muro. Per togliere la mascherina tenere il gruppo mascherina per i bordi con le due mani e premere forte con i pollici sui lati opposti del gruppo interruttore interno finché non fuoriesce dalla mascherina. Vedere la figura 1. 24758 5 Ricerca guasti Sintomo Cause probabili Soluzione Nessuna funzione operativa. Non è stata ripristinata l’alimentazione di rete. Sostituire il fusibile. Accendere (ON) l’alimentazione di rete. Accendere (ON) l’interruttore a muro. Catenella del ventilatore non impostata su HIGH (ALTO). Spegnere (OFF) l’alimentazione sull’interruttore a muro o l’alimentazione di rete. Impostare il ventilatore sulla velocità HIGH (ALTO). Cablaggio di comando errato. Verificare il cablaggio. Luce Ventilatore Premere qui Figura 3 - Posizioni dei morsetti Premere qui Vite di arresto (filo del ventilatore) Vite di arresto (VAC, non visibile) Ventilatore Figura 1 - Rimozione del gruppo interruttore dalla mascherina Hunter Fan Company Alimentazione Mascherina quadrata alternativa Figura 4 - Viti di arresto morsetti, vista dal basso 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA © 2015 Hunter Fan Company 41613-07 01/23/15 Hunter Fan Company Anahtar düzeneğini sokmak için, yön değiştirmeli tip kare ön yüze merkezleyin ve tüm altı tutma çıkıntısı yerlerine geçinceye ve anahtar düzeneği ön yüze sıfır oluncaya kadar ön yüze doğru bastırın. Şekil 2’ye bakın. Fan Hız Kontrol Fanı kontrol etmek için, Şekil 5’te gösterildiği gibi fan hızı kontrol kadranını istenen konuma ayarlayın. Soldan sağa konumlar: kapalı, yüksek, orta ve düşük. Fanın kendi üzerindeki hız kontrol çekme zinciri, duvar kontrolünün doğru çalışması için yüksek konuma ayarlanmalıdır. Tavan Fanı Duvar Kontrolü Duvar Kontrol Modelleri: 24758 Güç: 240 VAC, 1A Maksimum Kapalı Bu Talimatları Okuyun ve Saklayın Yüksek Orta UYARI: Elektrik çarpması riski Olası bir elektrik çarpmasından kaçınmak için fanınızın kablo bağlantılarını yapmadan önce ana gücü kapatarak hem çıkış kutusuna ve ilgili duvardaki elektrik düğmesine giden gücü kesin. Uyma • Bu ekipman test edilmiştir ve aşağıdaki standartlara uygundur: IEC 60669-1-1998 ve EN 60669-1-1999. • Tüm kablolama ulusal ve yerel elektrik standartlarına uygun olmalıdır. Kablolama hakkında bilginiz yoksa kalifiye bir elektrik teknisyeni kullanın. • Avusturya’daki yerel yasalar uyarınca, ulusal ve yerel standartlara göre bu kontrolün monte edilmesi için bir kalifiye elektrik teknisyeni gereklidir. • Aşırı ısınmadan ve ekipmanın olası hasarından kaçınmak için kontrol sistemini bir prize, floresan lamba düzeneğine, motorla çalışan bir cihaza veya trafoyla beslenen bir cihaza monte etmeyin. Sadece kanatlı tavan fanının donanımını kontrol etmek için kullanın. Sadece elektrikle yönü tersine çevrilebilir 1.0 Amper veya daha az gücündeki tavan fanlarla. Gölge kutuplu veya elektrikle yönü tersine çevrilemeyen motorlarla birlikte kullanılamaz. Hunter Original® ile birlikte kullanılması önerilmez. Kablolama Fan Hız Kontrol Tavan fanının gücünü ana elektrik panelinden kesin. Sigortayı çıkartın veya devre kesiciyi OFF (kapalı) konuma getirin. Duvar anahtarını kapatın. Kablo uçları düz olmalıdır ve uçlardan 13 mm’den fazla izolasyon sökülmemelidir. Kabloları terminallere sokmadan önce, ayar vidasını tamamen sökmeden kablo ucunun kolayca sokulmasını sağlamak için her bir terminaldeki terminal ayar vidalarını gevşetin. Şekil 2 ve 4’e bakın. Güç kablosunu VAC simgesi ile işaretlenmiş terminale bağlayın ve ayar vidasını iyice sıkın. Şekil 5- Hız Kontrol Fan kablosunu Fan simgesi ile işaretlenmiş terminale ve ayar vidalarını iyice sıkın. Bilgi için Şekil 3 ve 4’e bakın. Bağlantı noktalarında açıkta çıplak kablo olmadığından emin olun. Kabloları elektrik kutusuna itin ve verilmiş iki vidayı kullanarak duvar kontrol düzeneğini duvar elektrik kutusuna monte edin. Fan Kontrol Sorun Giderme Güç Ön Yüz Seçimi İki tip duvar ön yüzü verilmektedir. Ön yüzü sökmek için her iki elinizle ön yüz düzeneğini tutun ve ön yüzden çıkıncaya kadar iç anahtarı karşıt yönlerini başparmaklarınızla sıkıca bastırın. Şekil 1’e bakın. Düşük Şekil 2 - Anahtar Düzeneğinin Ön Yüze Sokulması Semptom Olası Nedenler Çözüm Hiçbir şey çalışmıyor. Ana Güç kaynağı yok. Sigortayı değiştirin. Ana Güç Kaynağını Açın (ON). Duvar Anahtarını açın (ON). Fan Çekme Zinciri HIGH (yüksek) konuma getirilmemiş. Duvar anahtarında veya ana güç kaynağında gücü KESİN. Fanı HIGH (yüksek) hıza ayarlayın. Kablolamanın doğru olup olmadığını kontrol edin. Kablo bağlantı noktalarını kontrol ederek onaylayın. 24758 5 Fan Buraya Basın Şekil 3 - Terminal Konumları Buraya Basın Ayar vidası (Fan Kablosu) Ayar vidası (VAC, görülemez) Fan Şekil 1 - Anahtar Düzeneğinin Ön Yüzden Sökülmesi Hunter Fan Company Güç Yön Değiştirmeli Kare Ön Yüz Şekil 4 - Terminal Ayar Vidaları, alttan görünüm. 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA © 2015 Hunter Fan Company 41613-15 01/23/15 Hunter Fan Company Για να εισαγάγετε τη διάταξη διακόπτη, τοποθετήστε τη στο κέντρο του ανοίγματος της εναλλακτικής πρόσοψης και πιέστε τη στην πρόσοψη, έως ότου και τα έξι γλωσσίδια συγκράτησης να μανδαλώσουν στη θέση τους και η διάταξη διακόπτη να εφαρμόσει στην πρόσοψη. Βλ. εικόνα 2. Έλεγχος ανεμιστήρα Έλεγχος ταχύτητας ανεμιστήρα Για τον έλεγχο του ανεμιστήρα, θέστε τον επιλογέα ταχύτητας ανεμιστήρα στην επιθυμητή θέση, όπως φαίνεται στην εικόνα 5. Οι θέσεις είναι απενεργοποίηση, υψηλή, μέση και χαμηλή, από αριστερά προς τα δεξιά. Προκειμένου ο επιτοίχιος έλεγχος να λειτουργεί σωστά, πρέπει η αλυσίδα ελέγχου της ταχύτητας στον ίδιο τον ανεμιστήρα να ρυθμιστεί στη θέση για υψηλή ταχύτητα. Επιτοίχια μονάδα ελέγχου για ανεμιστήρα οροφής Μοντέλα επιτοίχιας μονάδας ελέγχου: 24758 Χαρακτηριστικά: 240 VAC, 1 A μέγ. Διαβάστε και φυλάξτε αυτές τις οδηγίες ΠΡΟΕΙΔΟΠΟΙΗΣΗ: κίνδυνος ηλεκτροπληξίας Προκειμένου να αποφύγετε πιθανή ηλεκτροπληξία, διακόψτε πριν την καλωδίωση του ανεμιστήρα την ηλεκτρική τροφοδοσία, θέτοντας τους κεντρικούς διακόπτες τροφοδοσίας τόσο προς τον διανεμητή όσο και προς τον αντίστοιχο επιτοίχιο διακόπτη στη θέση απενεργοποίησης. Compliance • Αυτή η συσκευή έχει ελεγχθεί και συμμορφώνεται με τα πρότυπα: IEC 60669-1-1998 και EN 60669-1-1999. • Η καλωδίωση θα πρέπει να είναι εξ ολοκλήρου σε συμφωνία με τους εθνικούς και τοπικούς κώδικες. Εάν δεν διαθέτετε εξοικείωση με την καλωδίωση, θα πρέπει να απευθυνθείτε σε ειδικευμένο ηλεκτρολόγο. • Στην Αυστραλία, οι εθνικοί νόμοι απαιτούν αυτή η μονάδα ελέγχου να εγκατασταθεί από εκπαιδευμένο ηλεκτρολόγο, σύμφωνα με τους εθνικούς και τοπικούς κανονισμούς. • Για να αποφευχθεί η υπερθέρμανση και πιθανή βλάβη άλλου εξοπλισμού, μην συνδέεται στη μονάδα ελέγχου ρευματοδότη, συσκευή φθορίζοντα φωτισμού, συσκευή με κινητήρα ή συσκευή που τροφοδοτείται μέσω μετασχηματιστή. Χρησιμοποιήστε την αποκλειστικά για τον έλεγχο ενός ανεμιστήρα οροφής με πτερύγια. Απενεργοποίηση Καλωδίωση Μέση Χαμηλή Αποσυνδέστε την ηλεκτρική τροφοδοσία του ανεμιστήρα οροφής στον κεντρικό ηλεκτρικό πίνακα.. Αφαιρέστε την ασφάλεια ή θέστε τον διακόπτη κυκλώματος στη θέση απενεργοποίησης. Θέστε τον επιτοίχιο διακόπτη στη θέση απενεργοποίησης. Έλεγχος ταχύτητας ανεμιστήρα Τα άκρα των αγωγών πρέπει να είναι ίσια και να μην τους έχει αφαιρεθεί περισσότερο από 13 mm μόνωσης. Πριν να εισαγάγετε τα καλώδια στους ακροδέκτες, ξεβιδώστε τον ακέφαλο κοχλία κάθε ακροδέκτη αρκετά, ώστε να είναι δυνατή η εύκολη εισαγωγή του αγωγού του καλωδίου, χωρίς να αφαιρέσετε τελείως τον ακέφαλο κοχλία. Βλ. εικόνες 3 και 4. Συνδέστε το καλώδιο τροφοδοσίας στον ακροδέκτη που είναι σημειωμένος με το εικονίδιο τροφοδοσίας και σφίξτε καλά τον ακέφαλο κοχλία. Εικόνα 5 - Έλεγχος ταχύτητας Συνδέστε το καλώδιο του ανεμιστήρα στον ακροδέκτη με το εικονίδιο ανεμιστήρα στον ακροδέκτη με το εικονίδιο,σφίγγοντας καλά τους ακέφαλους κοχλίες των ακροδεκτών. Βλ. εικόνες 3 και 4 για αναφορά. Βεβαιωθείτε ότι δεν υπάρχουν εκτεθειμένα γυμνά καλώδια στα σημεία σύνδεσης. Σπρώξτε τα καλώδια στο κουτί συνδέσεων και αναρτήστε τη διάταξη της επιτοίχιας μονάδας ελέγχου στο επιτοίχιο κουτί συνδέσεων χρησιμοποιώντας τους δύο κοχλίες που παρέχονται. Για χρήση μόνο με ηλεκτρικά αντιστρέψιμους ανεμιστήρες οροφής με ονομαστική ένταση ρεύματος 1,0 Α ή μικρότερη. Ισχύς Όχι για χρήση με κινητήρες σχιστού πόλου ή μη αντιστρέψιμους. Δεν συνιστάται για χρήση με τον Hunter Original®. Επιλογή πρόσοψης Παρέχονται δύο προσόψεις διαφορετικού στυλ. Για να αφαιρέσετε την πρόσοψη, κρατήστε τη διάταξη της πρόσοψης από τις άκρες με τα δύο χέρια και πιέστε σταθερά με τους αντίχειρες στις αντίθετες πλευρές της εσωτερικής διάταξης του διακόπτη, έως ότου ελευθερωθεί από την πρόσοψη. Βλ. εικόνα 1. Υψηλή Εικόνα 2 - Εισαγωγή της διάταξης του διακόπτη στην πρόσοψη Αντιμετώπιση προβλημάτων Σύμπτωμα Πιθανές αιτίες Λύση Καμία λειτουργία δεν ενεργοποιείται. Δεν έχει αποκατασταθεί η κεντρική τροφοδοσία. Επανατοποθετήστε την ασφάλεια. Ενεργοποιήστε την κεντρική τροφοδοσία. Θέστε τον επιτοίχιο διακόπτη στη θέση ενεργοποίησης. Η αλυσίδα του ανεμιστήρα δεν είναι ρυθμισμένη στη θέση για υψηλή ταχύτητα. Θέστε τον επιτοίχιο διακόπτη στη θέση απενεργοποίησης ή διακόψτε την τροφοδοσία από τον κεντρικό πίνακα. Θέστε τον ανεμιστήρα στη θέση για υψηλή ταχύτητα. Λανθασμένη καλωδίωση της διάταξης ελέγχου. Επιβεβαιώστε τις συνδέσεις καλωδίωσης. 24758 Ανεμιστήρας Εικόνα 3 - Θέσεις ακροδεκτών Πιέστε εδώ Πιέστε εδώ Ακέφαλος κοχλίας (καλώδιο ανεμιστήρα) Ακέφαλος κοχλίας (τροφοδοσία, μη ορατό) Ανεμιστήρας Hunter Fan Company Ισχύς 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA Εναλλακτική τετράγωνη πρόσοψη Εικόνα 1 - Αφαίρεση της διάταξης του διακόπτη από την πρόσοψη. Εικόνα 4 - Ακέφαλοι κοχλίες ακροδεκτών, όψη από τα κάτω © 2015 Hunter Fan Company 41613-16 01/23/15 Hunter Fan Company Untuk memasukkan rangkaian sakelar, tengahkan rangkaian pada bukaan pelat muka model alternatif dan tekan masuk ke dalam pelat muka sampai keenam tab penahannya mengklik di tempatnya, dan rangkaian sakelar rata dengan pelat muka. Lihat Gambar 2. Kontrol Kipas Kontrol Kecepatan Kipas Untuk mengontrol kipas, putar tombol kontrol kecepatan kipas ke posisi yang diinginkan seperti ditunjukkan dalam Gambar 5. Posisinya adalah Mati, Tinggi, Sedang, dan Rendah dari kiri ke kanan. Rantai-tarik kontrol kecepatan pada kipas itu sendiri harus diatur ke Tinggi agar kontrol dinding berfungsi dengan benar. Kontrol Dinding untuk Kipas Langit-langit Model Kontrol Dinding: 24758 Rating: 240 VAC, 1A Maks Bacalah dan Simpan Petunjuk ini PERINGATAN: Risiko sengatan listrik Untuk menghindari kemungkinan sengatan listrik, sebelum memasang kabel kipas, putuskan aliran listrik dengan mematikan aliran listrik PLN ke stopkontak dan ke lokasi sakelar dinding yang terkait. Compliance • Peralatan ini telah diuji dan mematuhi: IEC 60669-1-1998 dan EN 60669-1-1999. • Semua pengawatan harus sesuai dengan peraturan kelistrikan nasional dan lokal. Jika Anda tidak terlalu mengerti pengawatan, Anda harus meminta bantuan teknisi listrik yang berkualifikasi. • Di Australia, undang-undang nasional mewajibkan agar pemasangan kontrol ini dilakukan oleh teknisi listrik yang berkualifikasi sesuai dengan peraturan nasional dan lokal. • Untuk menghindari panas berlebihan dan kemungkinan kerusakan pada peralatan lain, jangan memasang perangkat ini untuk mengontrol stopkontak, fikstur lampu fluoresen, perkakas yang dioperasikan dengan motor, atau perkakas yang dipasok dengan trafo. Mati Gambar 2 - Memasukkan Rangkaian Sakelar ke Pelat Muka Tinggi Pengawatan Sedang Kontrol Kecepatan Kipas Ujung kawat kabel harus lurus dan panjang isolasi yang dikupas tidak lebih dari 13 mm. Sebelum memasukkan kawat ke terminal, kendurkan sekrup pengikat terminal pada setiap terminal secukupnya untuk memungkinkan kawat kabel masuk dengan mudah, tanpa harus melepas sekrup pengikat sepenuhnya. Lihat gambar 3 dan 4. Sambungkan kabel listrik ke terminal yang ditandai dengan ikon VAC dan kencangkan sekrup pengikatnya kuat-kuat. Sambungkan kabel Kipas ke terminal dengan ikon Kipas , dan kemudian kencangkan sekrup pengikat terminalnya kuat-kuat. Lihat Gambar 3 dan 4 untuk acuannya. Gambar 5 - Kontrol Kecepatan Pastikan tidak ada kabel telanjang yang terbuka pada titik penyambungan. Dorong kabel masuk ke kotak listrik dan pasang rangkaian kontrol dinding ke kotak listrik dinding menggunakan kedua sekrup yang disediakan. Gunakan hanya untuk mengontrol satu kipas langit-langit bilahdayung dan. Untuk digunakan hanya dengan kipas langit-langit yang secara kelistrikan dapat dibalik dengan rating 1,0 A atau kurang. Pemecahan Masalah Listrik Tidak untuk digunakan dengan motor kutub-bayangan atau motor yang tidak dapat dibalik (satu arah putaran). Tidak disarankan untuk digunakan dengan Hunter Original®. Pemilihan Pelat muka Rendah Matikan aliran listrik ke kipas langit-langit pada panel listrik utama Lepaskan sekering atau geser pemutus arus ke posisi OFF. Matikan sakelar dinding. Gejala Kemungkinan Penyebab Tidak ada fungsi yang bekerja. Listrik Utama belum dinyalakan kembali. Ganti sekering. Hidupkan aliran listrik PLN. Hidupkan sakelar dinding. Rantai-tarik kipas tidak diatur ke TINGGI. Matikan aliran listrik pada sakelar dinding atau aliran listrik PLN. Atur kipas ke kecepatan TINGGI. Pengawatan kontrol salah. Periksa kembali sambungan pengawatan. 24758 5 Dua model pelat muka dinding disediakan. Untuk melepaskan pelat muka, pegang rangkaian pelat muka pada tepi-tepinya dengan kedua tangan dan tekan kuat-kuat dengan ibu jari pada sisi yang berseberangan dari rangkaian sakelar dalam sampai menceklek keluar dari pelat muka. Lihat gambar 1. Solusi Kipas Gambar 3 - Lokasi Terminal Tekan di Sini Tekan di Sini Sekrup Pengikat (Kabel Kipas) Sekrup Pengikat (VAC, tidak terlihat) Kipas Hunter Fan Company Listrik 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA Pelat Muka Alternatif Persegi Gambar 1 - Melepaskan Rangkaian Sakelar dari Pelat Muka. Gambar 4 - Sekrup Pengikat Terminal, dilihat dari bawah © 2015 Hunter Fan Company 41613-17 01/23/15
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Hunter Fan 24758 El manual del propietario

Tipo
El manual del propietario