Broan 689 Guía de instalación

Tipo
Guía de instalación

Este manual también es adecuado para

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qual-
ified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and stan-
dards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manu-
facturer's guideline and safety standards such as those pub-
lished by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air Condi-
tioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a bathtub or shower when installed in
a GFCI protected branch circuit.
8. Install fan at least five feet (1.52 m) above the floor.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRI-
CA, O LESIONES A PERSONAS, CUMPLA LOS SIGUIENTES PUN-
TOS:
1. Solamente use esta unidad de la manera propuesta por el fabri-
cante. Si tiene alguna pregunta, póngase en contacto con el
fabricante en la dirección o teléfono anotados en la garantía.
2. Antes de limpiar o de poner en servicio la unidad, apague el
interruptor en el panel de servicio, y asegure el panel de servicio
para evitar que se encienda accidentalmente. Cuando el dispos-
itivo para desconectar el servicio eléctrico no puede ser cerrado
con algún tipo de traba, sujete fuertemente al panel de servicio,
una etiqueta de advertencia prominente.
3. El trabajo de instalación y el alambrado eléctrico deben llevarse a
cabo por personal calificado de acuerdo con todos los códigos y
las normas aplicables, incluyendo los códigos y normas de con-
strucción contra incendios.
4. Se requiere una cantidad de aire suficiente para la combustión y
escape de gases por la chimenea del equipo de quemado de
combustible para evitar salirse de las especificaciones y están-
dares de seguridad del fabricante, tales como los publicados por
la Asociación nacional de protección contra incendios (NFPA por
sus siglas en Inglés), y la Sociedad americana de ingenieros de
calefacción, refrigeración y aire acondicionado (ASHRAE por sus
siglas en Inglés), y los códigos de las autoridades locales.
5. Cuande corte o taladre en una pared o techo, no dañe los cables
eléctricos ni otras instalaciones ocultas.
6. Los ventiladores con ductos siempre deben de ventilar hacia el
exterior.
7. Aceptable si se lo usa por encima de una tina o ducha instaladas
en un circuito derivado protegido GFCI (con interruptor accionado
por corriente de pérdida a tierra).
8. Instálelo por lo menos a 152 cm sobre el piso.
9. NUNCA coloque un interruptor donde pueda ser alcanzado des-
de la bañera o la ducha.
10. Esta unidad debe conectarse a tierra.
PRECAUCIÓN
1. Sólo para uso de ventilación general. No se use para extraer materiales o vapores peligrosos o explosivos.
2. Para evitar daños al cojinete del motor y/o impulsores ruidosos o desequilibrados, mantenga la fuente de
potencia lejos de rocíos de pared seca, de polvo de construcción, etc.
3. Lea la etiqueta de especificaciones en el producto para mayor información y requisitos.
ADVERTENCIA
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials
and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
3. Please read specification label on product for further information and requirements.
INSTALLATION
1. Remove motor plate from housing by pushing down on rib in plate while pulling out on side
of housing. Motor plate may also be removed by inserting a straight-blade screw driver into
slot in housing and twisting screw driver. (FIG. 1)
2. Remove wiring cover from housing by pulling straight out. Unit is shipped ready to wire
through the top of housing. To wire through the side, bend housing flap to cover top hole and
expose side hole. DO NOT BREAK OFF FLAP. If flap breaks, Plug unused hole using standard
electrical hole plug. (FIG. 2)
3. Turn off electrical power at service entrance and connect power cable to housing using
appropriate connector. Wire black to black, white to white, and green to green or bare wire..
Push all wiring up into corner of unit and replace wiring cover. Make sure cover holds housing
flap in place against side or top of housing.
CAUTION: DO NOT ALLOW WIRES TO EXTEND OUTSIDE OF WIRING BOX. Wire left
exposed will become pinched or cut when motor plate is installed. Electrical shock may
result. (FIG. 3)
4. Choose the location for your fan. For best performance, use the shortest possible duct run and
a minimum number of elbows, For wall installations: Position unit so damper flap closes when
unit is off.
READ AND SAVE THESE
INSTRUCTIONS
MODELS 670, 671, 688 & 689
CEILING/WALL FANS
LEA Y CONSERVE ESTAS
INSTRUCCIONES
MODELOS 670, 671, 688 Y 689
VENTILADORES DE TECHO
WIRING
COVER
CUBIERTA DEL
ALAMBRADO
HOUSING
FLAP
SOLAPA DE LA
CAJA
SCREWDRIVER
SLOT
RANURA PARA
DESARMADOR
FIG. 3
FIG. 1
1. Remueva la placa del motor de la caja empujando hacia abajo sobre la costilla de la placa a la vez que se
jala hacia afuera del lado de la caja. La placa del motor puede también removerse introduciendo un
desarmador en la ranura de la caja y haciéndolo girar. (FIG. 1)
2. Retire la cubierta de la caja empujando directamente hacia el exterior. La unidad se envía lista para tender
el alambrado desde la parte superior de la caja. Para alambrar a través de uno de los lados, doble la solapa
de la caja hasta cubrir el agujero superior y exponer el agujero lateral. NO ROMPA LA SOLAPA. Si la solapa
se rompe, cubra el agujero que no se utiliza con tapones eléctricos estan. (FIG. 2)
3. Apaque la fuente de energía eléctrica de la entrada de servicio y conecte el cable de energía elétrica
en la caja usando la conexión appropiada. El alambre negro con nergo y el blanco con blanco, y verde a verde
o alambra desnudo.
Empuje todo el alambre hacia arriba y hacia la esquina de la unidad y reemplace la cubierta de la unidad.
Asegúrese de que la cubierta sostiene la solapa de la caja en su lugar contra la parte lateral o superior de
la caja. PRECAUCIÓN: NO PERMITA QUE LOS ALAMBRES SE EXTIENDAN HACIA EL EXTERIOR DE
LA CAJA DE ALAMBRADO. El alambre que quede expuesto puede ser rasgado o cortado cuando
se instale la placa del motor. Esto puede dar como resultado una descarga eléctrica. (FIG. 3)
120 VAC LINE IN
LINEA DE ENTRADA
A 120 VCA
BLACK
NEGRO
BLACK
NEGRO
GROUND
TIERRA
WHITE TO
WHITE
BLANCO A
BLANCO
SWITCH OR TIMER
INTERRUPTOR O
REGULADOR
GREEN TO
GREEN OR
BARE WIRE
VERDE A
VERDE 0
ALAMBRE
DESNUDO
SWITCH BOX
CAJA DE
INTERRUPTORES
RECEPTACLE
RECEPTÁCULO
WHITE TO
WHITE
BLANCO A
BLANCO
BLACK TO
BLACK
NEGRO A
NEGRO
INSTALACIÓN
USE AND CARE
DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING
THE UNIT.
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply and clean the fan as described
below:
TO CLEAN GRILLE - Use a mild detergent, such as dishwashing ligquid, and dry with a soft cloth.
DO NOT USE ABRASIVE CLOTHS, STEEL WOOL PADS, OR SCOURING POWDERS.
TO CLEAN FAN ASSEMBLY - Unplug motor cord from receptacle. To remove motor plate: Find the
single tab on the motor plate (located next to the receptacle). Push up near motor plate tab while
pushing out on side of housing. Or insert a straight-blade screwdriver into slot in housing (next
to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND
ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
TO REASSEMBLE ALL ABOVE PARTS - Reverse all procedures explained above.
MAINTENANCE
The motor is permanently lubricated and never needs oiling. If the motor bearings are making
excessive or unusual noises, replace the motor with the exact service motor. You should replace
the impeller at the same time.
FIG. 2
USO Y CUIDADO
DESCONECTE EL SUMINISTRO ELÉCTRICO Y BLOQUEE EL PANEL DE SERVICIO ANTES DE DAR
SERVICIO A LA UNIDAD.
MANTENIMIENTO PREVENTIVO
Un ventilador limpio proporciona mejor servicio. Desconecte el suministro eléctrico y limpie el ventilador
de la siguiente manera:
PARA LIMPIAR LA REJILLA – Lávela con detergente suave tal como líquido para lavar vajilla; séquela
con un paño suave. NO USE PAÑOS ABRASIVOS, ALMOHADILLAS DE LANA DE ACERO NI POLVOS
ABRASIVOS.
PARA LIMPIAR EL CONJUNTO DEL VENTILADOR – Desconecte el cable del motor de su receptáculo.
Para quitar la placa del motor: Localice la aleta única de la placa del motor (se encuentra junto al
receptáculo). Empuje hacia arriba cerca de la aleta de la placa del motor mientras empuja hacia afuera el
costado de la cubierta. O bien, introduzca un destornillador de punta recta en la ranura de la cubierta
(junto a la aleta) y haga girar el destornillador. Con una aspiradora limpie suavemente el ventilador, el
motor y el interior de la cubierta. NO SUMERJA NUNCA EN AGUA LAS PIEZAS METÁLICAS NI LAS
ELÉCTRICAS.
PARA VOLVER A MONTAR TODAS LAS PIEZAS ANTERIORES – Haga el procedimiento que se
acaba de explicar, pero en orden invertido.
MANTENIMIENTO
El motor está permanentemente lubricado y nunca necesitará aceite. Si los cojinetes del motor están
haciendo ruido excesivo o inusitado, reemplace el motor con el motor de servicio exacto. Al mismo
tiempo debe reemplazar el pistón impulsor.
5. New installation prior to finishing the ceiling or wall:
MAKE SURE HOUSING WILLBE FLUSH WITH FIN-
ISHED CEILING OR WALL. Slotted tabs are provided
to locate housing flush with 1/2" ceiling or wall material.
Bend tabs outward 90
0
(Use a screw driver if desired)
and position housing so that tabs rest against bottom
edge of joists (or front of stud). Nail housing to joist or
stud using four nails to ensure a solid, quiet installation.
Ceiling installations: Tabs on opposite side of housing
can be bent
outward to rest on top of 1/2" ceiling material
and provide extra stability. (FIG. 4)
5. Replacement installation:
Position housing so that it is centered in existing
opening. MAKE SURE HOUSING IS FLUSH WITHFIN-
ISHED CEILING OR WALL. After making electrical and
ductwork connections (see steps 4, 5 and 6), nail
housing in place. Drive nails through the housing where
indicated by arrows. (FIG. 5)
5. New installation in an existing ceiling or wall:
From above ceiling or behind wall, position housing
against stud or joist. Trace outline of housing on ceiling
or wall material. (FIG. 6) Set housing aside and cut
opening. Place housing in opening such that its
BOTTOM EDGE IS FLUSH WITH FINISHED CEILING
OR WALL. 1/2" ceiling or wall material: Bend tabs
outward 90
0
(use a screwdriver if desired) to rest on
top of ceiling or wall material and provide extra stability.
Nail in place using four nails to ensure a solid, quiet
installation. (FIG. 7)
6. Install 3" round duct onto damper/duct connector. If
rigid ductwork is used, its seam should be positioned
at top of damper/duct connector. Tape the joint and
extend ducting to a wall cap or roof cap. Make sure the
damper operates freely. Ceiling or wall can now be
finished.
NOTE: If damper detaches from duct connector, re-
insert it by squeezing duct connector top-to-bottom
while guiding posts on damper flap into holders in
duct connector. The horizontal rib should be on the
outside surface of damper flap and damper flap
should move freely inside of duct connector.
7. Replace the motor plate removed in Step 1. Insert two
motor plate tabs into slots in housing and then pivot
motor plate up until the third tab on plate snaps into
matching slot in housing. Make sure tabs hold motor
plate securely in place. Plug in motor. (FIG. 8)
8. Squeeze grille springs together and insert springs into
slots in motor plate. (FIG. 9) Push grille up against
ceiling or wall. (FIG. 10)
4. Escoja la posición de su ventilador. Para un mayor
rendimiento use el ducto más corto posible y un número
mínimo de codos. Para instalaciones en la pared: Coloque
la unidad de forma que la tapa del humidificador se cierre
cuando la unidad se encuentre apagada.
5. Instalación nueva antes de poner los acabados del techo
o la pared:
ASEGÚRESE DE QUE LA CAJA SE ENCUENTRE AL
NIVEL DEL TECHO O LA PARED. Se proporcionan
pestañas ranuradas para nivelar la caja con 1/2" del techo
o material de la pared. Doble las pestañas hacia afuera
a 90 grados (use un desarmador si asi lo desea) y coloque
la caja de forma que las pestañas descansen contra el
extremo del fondo de los travesaños (o del frente de la
viga). Clave la caja al travesaño usando cuatro clavos
para asegurar una instalación sólida y silenciosa. Insta-
laciones en techos: las pestañas que se encuentran en
la parte opuesta de la caja pueden doblarse hacia afuera
hasta descansar encima de 1/2 " de material de techo para
proveer estabilidad adicional. (FIG. 4)
5. Instalación de reemplazo:
Coloque la caja de forma que esté centrada en la abertura
existente. ASEGÚRESE DE QUE SE ENCUENTRE AL
NIVEL DEL TECHO O LA PARED. Después de hacer las
conexiones eléctricas y del ducto de trabajo (Vea los
pasos 4, 5, y 6), clave la caja en el lugar escogido. Coloque
los clavos en los lugares marcados con una flecha. (FIG.
5)
5. Instalación nueva en un techo o pared existentes:
Desde arriba del techo o detrás de la pared, coloque la
caja contra la viga o travesaño. Marque los contornos de
la caja en el material del techo o pared. (FIG. 6) Ponga
de lado la caja y corte la abertura. Coloque la caja en la
abertura de forma que EL EXTREMO DEL FONDO SE
ENCUENTRE A NIVEL CON EL TECHO ACABADO O LA
PARED. 1/2 " de techo o material de pared: Doble las
pestañas 90 grados
hacia el exterior (use un desarmador
si así lo desea) para descansar encima de techo o material
de pared y proporcionar así una mayor estabilidad. Clave
en su lugar utilizando cuatro clavos para asegurar una
instalación sólida y silenciosa. (FIG. 7)
6. Instale ducto redondo de 3" en la conexión del humidifi-
cador/ ducto. Si se utiliza ducto de trabajo rígido, su
costura debera colocarse en la parte superior del humid-
ificador/ducto. Encinte la unión y extienda el ducto hacia
la tapa de la pared o la tapa del techo. Asegúrese de que
el humidificador funciona libremente. El techo o pared
pueden entonces ser acabados.
NOTA: Si la aleta del regulador de tiro se desprende
del conectador del conducto, vuelva a introducirla
comprimiendo el conectador de arriba a bajo al
tiempo que guía los postes de la aleta para
introducirlos en el soporte del conectador. El saliente
horizontal debe quedar en la superficie externa de
la aleta del regulador de tiro, y ésta debe poder
moverse libremente dentro del conectador del
conducto.
7. Reemplace la placa del motor que fue removida en el paso
1. Inserte dos pestañas de la placa del motor dentro de
las ranuras en la caja y entonces jale usando la placa del
motor como pivote hasta que la tercera pata de la placa
encaja en la ranura correspondiente de la caja. Asegúrese
de que las pestañas sostienen la placa del motor de forma
segura. Conecte el motor. (FIG. 8)
8. Presione conjuntamente los resortes de la parrilla e
insértelos dentro de las ranuras de la placa del motor.
(FIG. 9) Empuje la parrilla contra el techo o pared. (FIG.
10)
FIG. 4
FIG. 5
12
4
2
7
3
6
8
5
10
11
BROAN ONE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be
free from defects in materials or workmanship for a period of one year from the date of original
purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUD-
ING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any
product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND
TUBES. This warranty does not cover (a) normal maintenance and service or (b) any
products or parts which have been subject to misuse, negligence, accident, improper
maintenance or repair (other than by Broan), faulty installation or installation contrary to
recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the
express warranty. Some states do not allow limitation on how long an implied warranty lasts,
so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE
THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY.
BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR
PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary
from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address stated below or
telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe
the nature of any defect in the product or part. At the time of requesting warranty service,
you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027
61574 99041024AA
SERVICE PARTS KEY PART NUMBER NO. PIEZAS DE SERVICIO
NO. NO. PIEZ CÓDIGO
Grille Assembly (Includes Key Nos 1 97011723 1 Ensamble de la parrilla
1 & 2) (Incluye código Nos. 1 y 2)
Grille Spring (2 Required) 2 99140187 2 Resorte de la parrilla
(Son necesarios 2)
Motor (Model 670) 3 99080254 3 Motor (Modelo 670)
Motor (Model 671) 99080255 Motor (Modelo 671)
Motor (Model 688) 97012041 Motor (Modelo 688)
Motor (Model 689) 97012042 Motor (Modelo 689)
Motor Plate 4 98006791 4 Placa del motor
Blower Wheel (Model 670 & 671) 5 99110655 5 Rotor de soplo (Modelo 670 y 671)
Blower Wheel (Model 688 & 689) 6 99111002 6 Rotor de soplo (Modelo 688 y 689)
Nut #6-32 (2 Required) 7 99260428 7 Tuerca No. 6-32 (Son necesarias 2)
Damper/Duct Connector 8 97016377 8 Conexión humidificador/Ducto
(Models 670, 671, 688, 689) (Modelos 670, 671, 688 y 689)
Damper/Duct Connector 9 97015577 9 Conexión humidificador/Ducto
(Model 1667HMTL)) (Modelos 1667HMTL)
Receptacle 10 99271252 10 Receptáculo
Wiring Cover 11 98006773 11 Cubierta del alambrado
Housing Assembly 12 97008319 12 Ensamble de la caja
Screw, #8-18 13 99150478 13 Tornillo, #8-18
Always order replacement parts by "PART NUMBER" - not by "KEY NO."
Siempre encargue piezas de reemplazo por "NO. PIEZA" y no por "NO. CÓDIGO"
PIEZAS DE
SERVICIO
SERVICE
PARTS
FIG. 6 FIG. 7
FIG. 8 FIG. 9
FIG. 10
TABS
PESTAÑAS
¬¬
¬¬
¬
¬¬
¬¬
¬
¬¬
¬¬
¬
1
9
13
GARANTÍA BROAN LIMITADA POR UN AÑO
Broan garantiza al consumidor comprador original de sus productos que dichos productos
carecerán de defectos en materiales o en mano de obra por un período de un año a partir de
la fecha original de compra. NO EXISTEN OTRAS GARANTÍAS, EXPRESAS O IMPLÍCI-
TAS, INCLUYENDO, PERO NO LIMITADAS A, GARANTÍAS IMPLÍCITAS DE COMER-
CIALIZACIÓN O APTITUD PARA UN PROPÓSITO PARTICULAR.
Durante el período de un año, y a su propio criterio, Broan reparará o reemplazará, sin costo
alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de
servicio y uso.
ESTA GARANTÍA NO SE APLICA A TUBOS Y ARRANCADORES DE LÁMPARAS
FLUORESCENTES. Esta garantía no cubre (a) mantenimiento y servicio normales o (b)
cualquier producto o piezas que hayan sido utilizadas de forma errónea, negligente, que hayan
causado un accidente, o que hayan sido mantenidas o reparadas inapropiadamente(por otras
compañías que no sea Broan), instalación defectuosa, o instalación contraria a las
instrucciones de instalación recomendadas.
La duración de cualquier garantía implícita se limita a un período de un año como se especifica
en la garantía expresa. Algunos estados no permiten limitaciones en cuanto al tiempo de
expiración de una garantía implícita, por lo que la limitacíon antes mencionada puede no
aplicarse a usted.
LA OBLIGACIÓN DE BROAN DE REPARAR O REEMPLAZAR, SIGUIENDO EL CRITERIO
DE BROAN, DEBERÁ SER EL ÚNICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRA-
DOR BAJO ESTA GARANTÍA. BROAN NO SERÁ RESPONSABLE POR DAÑOS
ACCIDENTALES, CONSIGUIENTES, O POR DAÑOS ESPECIALES SURGIDOS O EN
CONEXIÓN CON EL USO O EL RENDIMIENTO DEL PRODUCTO. Algunos estados no
permiten la exclusión o limitación de daños accidentales o consiguientes, por lo que la limitación
antes mencionada puede no aplicarse a usted. Esta garantía le proporciona derechos legales
específicos, y usted puede también tener otros derechos, los cuales varían de estado a
estado. Esta garantía reemplaza todas las garantías anteriores. Para calificar en el servicio
de garantía, usted debe (a) notificar a Broan al domicilio que se menciona abajo o al telefono:
1-800-637-1453, (b) dar el número del modelo y la identificación de la pieza y (c) describir la
naturaleza de cualquier defecto en el producto o pieza. En el momento de solicitar servicio
cubierto por la garantía, usted debe presentar evidencia de la fecha original de compra.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 U.S.A.
  • Page 1 1
  • Page 2 2

Broan 689 Guía de instalación

Tipo
Guía de instalación
Este manual también es adecuado para

en otros idiomas