Graham Field NEB-U-TYKE JB0112-164 Manual de usuario

Tipo
Manual de usuario

Este manual también es adecuado para

Read this manual before operating the nebulizer.
Save this manual for future reference.
Note: The most current version of this manual
can be found online at www.grahameld.com.
Federal Law (USA) restricts this device to sale by or
on the order of a physician. This device should not
be used unless the operator has been instructed by a
qualied healthcare professional.
Neb-u-Tyke RR Train
Nebulizer Compressor
Item JB0112-164
User Manual
JB0112-164-INS-LAB-RevB09
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 2
Graham-Field and John Bunn are registered trademarks, and Neb-u-Tyke is a
trademark, of GF Health Products, Inc.
Packaging, warranties, products, and specications are subject to change with-
out notice. GF Health Products, Inc. is not responsible for typographical errors.
CONTENTS
INTRODUCTION ...........................................................................................................3
INTENDED USE ........................................................................................................... 3
SYMBOLS KEY ............................................................................................................ 3
IMPORTANT SAFETY PRECAUTIONS .......................................................................4
PRODUCT DESCRIPTION ...........................................................................................6
FEATURES AND COMPONENTS ................................................................................ 6
SET-UP ..........................................................................................................................7
OPERATION .................................................................................................................8
SAFETY OVERLOAD ................................................................................................... 9
MAINTENANCE ............................................................................................................9
CLEANING THE COMPRESSOR’S OUTER CASE .................................................... 9
CLEANING THE NEBULIZER CUP ........................................................................... 10
REPLACING THE FILTER .......................................................................................... 10
STORAGE ....................................................................................................................11
TROUBLESHOOTING ................................................................................................11
SPECIFICATIONS .......................................................................................................12
LIMITED WARRANTY ................................................................................................13
COMPRESOR DE NEBULIZADOR MANUAL USUARIO (EN ESPAÑOL) ...............17
This product has been tested and successfully approved with the
following standards:
UL1431
EN 60601-1
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 3
INTRODUCTION
This user manual contains important information and
safety precautions for the John Bunn Neb-u-Tyke RR Train
Nebulizer Compressor.
Before using your Nebulizer Compressor, please read and
understand this entire user manual. Take special note of all
safety precautions marked DANGER and WARNING. Save
this user manual for future reference.
Intended Use
The Neb-u-Tyke RR Train Compressor Nebulizer System is
designed to provide a source of compressed air for aerosol
therapy. It is used in conjunction with a jet (pneumatic)
nebulizer to produce medicated aerosols for inhalation by
pediatric and adult patients with respiratory symptoms.
Indications for therapy include asthma, chronic bronchitis,
infection of the upper respiratory tract, chronic obstruc-
tive pulmonary disease, and other respiratory disorders in
accordance with a physician’s prescription. Do not use this
product for any other purpose than the preceding. This
device can be used with adult or pediatric patients under
physician’s prescription.
Symbols Key
O Off
I On
~ Alternating current
IPX0 Enclosed equipment without protection against ingress of water
Attention (read the instructions)
II Class II (not applicable for UL1431)
BF: This product is in a rdance with the degree of protection against electric
shock for type BF equipment. (not applicable for UL1431)
Disposal of Electrical & Electronic Equipment (WEEE): This product should
not be treated as household waste, but submitted to an appropriate collection
point for the recycling of electrical and electronic equipment. For more detailed
information about the recycling of this product, please contact your local city
office, household waste disposal service, or the Graham-Field authorized
distributor from whom you purchased this product.
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 4
IMPORTANT SAFETY PRECAUTIONS
When using electrical products, especially when children
are present, always follow basic safety precautions, includ-
ing the following:
DANGER: Indicates a potential hazard situation or unsafe
practice that, if not avoided, will result in death or serious
personal injury.
WARNING: Indicates a potential hazard situation or unsafe
practice that, if not avoided, could result in death or seri-
ous personal injury.
sCaution: Indicates a potential hazard or unsafe prac-
tice that, if not avoided, could result in minor personal
injury or product/property damage.
Note: Provides application recommendations or other useful
information to ensure that you get the most from your prod-
uct.
READ ALL INSTRUCTIONS BEFORE USING
DANGER: To reduce the risk of electrocution:
1. Always unplug this product immediately after use.
2. Do not use this product while bathing, showering, wash-
ing dishes, or close to water sources of any kind.
3. Do not place or store device where it can fall or be pulled
into a tub or sink.
4. Do not place device in or drop into water or other liquid.
5. Do not reach for a device that has fallen into water. Un-
plug it immediately.
WARNING: To reduce the risk of burns, electrocution, re
or personal injury:
1. Never leave this device unattended when plugged in.
2. This product contains small parts that may present a
choking hazard to small children, and the tubing may
present a strangulation hazard. Always use close supervi-
sion when this device is used by or near children or those
who require close supervision.
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 5
3. Children under the age of 3, or any patient who is unable
to use a mouthpiece properly under supervision, should
use a mask.
4. Use this device only as intended and described in this
manual. Do not use attachments or accessories not rec-
ommended by GF Health Products, Inc.
5. Never operate this product if:
a. it has a damaged cord or plug,
b. it is not working properly or it has been dropped or
damaged,
c. it has been dropped into water.
Return the product to your Graham-Field authorized dis-
tributor for examination and repair.
6. Keep the cord away from heated surfaces.
7. Never block the air openings of this product or place it
on a soft surface, such as a bed or couch, where the air
openings may be blocked. Keep the air openings free of
lint, hair and the like.
8. Never drop or insert any object into any openings or hose.
9. Never use this device while drowsy or sleeping.
10. Do not use this device outdoors or operate where aerosol
(spray) products are being used.
11. Do not use this device in the presence of ammable anes-
thesia or where oxygen or nitrous oxide is being adminis-
tered. This device has no AP or APG protection.
12. Connect this device to a properly grounded outlet only.
13. This device has a polarized plug (one blade is wider than
the other). As a safety feature, this plug will t into a
polarized outlet only one way. If the plug does not t fully
into the outlet, reverse the plug. If it still does not t, con-
tact a qualied electrician. Do not modify the plug in any
way. Do not attempt to defeat this safety feature.
14. Unplug the device before lling or cleaning the nebulizer.
15. This device is oil-free. Do not lubricate.
16. Do not remove the jet nebulizer while the device is operating.
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 6
17. Do not leave medication inside the jet nebulizer when it is
not in use.
18. Use the nebulizer intermittently; the maximum operating
period is 30 minutes. The nebulizer must stand unused for
30 minutes between uses.
19. The mouthpiece and masks are for use by one person
only; in order to avoid infection, do not share them.
PRODUCT DESCRIPTION
Features and Components
Please note nebulizer features and components, labeled in
the illustration below.
reservoir tube
air outlet connector
for tubing
filter cap
ON/OFF switch
adult mask
nebulizer cup
mouthpiece
tubing
T adapter
pediatric mask
Neb-u-Tyke RR Train
Nebulizer Compressor
Note: RR Train replacement parts are available at
www.grahamfield.com or from your Graham-Field authorized
distributor.
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 7
SET-UP
Note: Before initial operation, clean the nebulizer cup as-
sembly following the instructions given in MAINTENANCE/
Cleaning the Nebulizer Cup.
WARNING: Ensure that the nebulizer compressor is un-
plugged during set-up.
1. Before each use, inspect the compressor and nebulizer
cup assembly for damage or wear; replace as needed.
2. Place the compressor on a table or other at stable sur-
face (not on the oor), in an area that is clean and dust-
free. Be sure you can easily reach the controls when
seated.
3. Open the nebulizer medication cup: Twist the cap coun-
ter-clockwise until it stops, then lift cap off.
4. Pour the prescribed medication into the nebulizer medi-
cation cup. Do not ll with more than 5 ml per treat-
ment.
5. Install cap on cup. Turn clockwise to
tighten.
6. If using the mouthpiece for treatment,
proceed to step 7. If using a mask,
install the bottom part of the mask
directly onto the top of the nebulizer
medication cup cap as shown at right.
Proceed to step 9.
7. Insert mouthpiece into large end of
T adapter.
install cap
on cup
cap
cup
install mask
on cap
mask
cap
assemble
mouthpiece
and T adapter
T adapter
mouthpiece
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 8
Note: The reservoir tube, shown in the illustration earlier in
this manual, acts as a holding tank for the mist, reducing the
amount lost during treatment. Its use is optional. If you wish
to use the reservoir tube, install it now on the small end of
the T adapter.
8. Install T adapter onto top of nebulizer
medication cup cap.
9. Connect the tubing to the adapter on the
bottom of the nebulizer medication cup.
10. Connect the tubing's other end to the
compressor air outlet connector.
WARNING: Before use, check that all parts are securely
connected. Use of an improperly assembled nebulizer
could diminish or prevent adequate delivery of medication
and the effectiveness of the treatment.
OPERATION
sCaution: The Neb-u-Tyke RR Train Nebulizer Compres-
sor is designed for intermittent use only. Do not op-
erate it continuously for more than 30 minutes for a
single use without turning it off and allowing a cooling
period of least 30 minutes.
1. Ensure that the ON/OFF switch is in the OFF position.
2. Plug the power cord into a properly grounded electrical
wall outlet.
3. Move the ON/OFF switch to the ON position to start the
compressor.
4. Place the nebulizer mouthpiece between teeth and close
mouth (or install the mask on face).
5. As aerosol starts owing, inhale deeply and slowly
through mouthpiece (or mask).
WARNING: Never use a nebulizer with a clogged nozzle.
If the nozzle is clogged, the aerosol mist will be reduced,
altered or stopped, which will diminish or eliminate the ef-
fectiveness of the treatment. If clogging occurs, replace the
nebulizer.
install
T adapter
on cap
T adapter
cup
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 9
Note If you need to interrupt treatment, move the ON/OFF
switch to the OFF position.
6. When the treatment is complete, move the ON/OFF
switch to the OFF position to turn off the compressor.
7. Unplug the compressor from power outlet.
8. Disconnect nebulizer from tubing.
9. Clean nebulizer as instructed in MAINTENANCE/Clean-
ing the Nebulizer Cup.
Safety Overload
Note: Do not exceed 30 minutes of continuous operation.
1. The motor of this device has a built-in thermal overload
protector. Should the motor overheat, the protector
will automatically shut off the motor. Should this occur,
move the ON/OFF switch to the OFF position and allow
the motor to cool down for approximately 30 minutes
before turning it on again.
2. If the overload protector shuts off the motor frequently,
you may have an unstable voltage situation.
3. If the device shuts down and cannot restart, it may need
to be replaced. Call your Graham-Field authorized dis-
tributor immediately.
MAINTENANCE
Cleaning the Compressor’s Outer Case
WARNING: Electrical shock hazard. Do not remove the
outer case of the device. All disassembly and maintenance
of the device must be performed by a qualied service
technician. Refer service to qualied service personnel.
WARNING: This device does not require oil. Do not attempt
to lubricate any internal parts.
WARNING: Unplug device before cleaning. Do not sub-
merge in water for cleaning.
Wipe the compressor's outer case with a clean, damp cloth
weekly to keep it dust-free. Do not use any powdered type
cleaners or soap.
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 10
Cleaning the Nebulizer Cup
All parts of the disposable nebulizer, except tubing, should
be thoroughly cleaned after each use. If your physician
species a specic cleaning procedure, follow that proce-
dure.
WARNING: To prevent possible risk of infection from con-
taminated medication, clean the nebulizer after each treat-
ment.
1. After each use, disassemble the nebulizer cup, T adapt-
er and mouthpiece completely, wash all parts in warm
soapy water, and rinse thoroughly. Allow to air dry.
Store in a clean, dry location.
2. Once daily, after washing as above, soak nebulizer com-
ponents in a fresh solution consisting of one part warm
water and one part white vinegar for 30 minutes fol-
lowed by a warm water rinse. Allow to air dry. Store in a
clean, dry location.
Replacing the Filter
Note: Change the filter once every 30 days or when the
filter changes color. Additional filters can be purchased at
www.grahamfield.com or from your Graham-Field authorized
distributor.
1. Ensure that ON/OFF switch is in the OFF position. Open
the lter cap located next to the ON/OFF switch.
2. Remove the dirty lter with a small, pointed object. Dis-
card the lter.
3. Replace with a clean lter.
4. Replace the lter cap.
sCaution: Do not use cotton or other materials as a filter.
sCaution: Do not wash or clean the filter.
sCaution: Do not reuse the filter. Do not operate com-
pressor without a filter. Compressor damage can result.
sCaution: The disposable nebulizer kit is for single pa-
tient use only.
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 11
Storage
Keep the device and accessories dry. Avoid exposure to
direct sunlight.
TROUBLESHOOTING
If your Neb-u-Tyke RR Train Nebulizer Compressor fails
to function, consult the following Troubleshooting guide.
If the problem persists, consult your Graham-Field autho-
rized distributor.
Problem Cause and Solution
Device doesn’t
operate
Check if plug is properly fit into a grounded electrical outlet.
When device has been run continuously for more than 30 minutes
just before using, auto-shut-down may have been activated by the
built-in thermal protector; ensure that device is OFF for at least 30
minutes before next usage.
Nebulization is
weak
Check for proper electrical voltage.
Check tubing for blockage or air leakage at connection to Neb-u-Tyke
compressor or nebulizer cup; replace as needed.
Check that the nebulizer cup is properly assembled and not
damaged. If there is any damage, replace as needed.
Check if filter is dirty; replace filter as needed.
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 12
SPECIFICATIONS *
Specication Description
Max pressure (compressor) 32.5 PSI
Max flow rate Approximately 10 LPM
Nebulization rate .33 ml/min
Particle dimension .5 - 5 microns
Capacity 5 ml
Filter Sponge
Dimensions (LxWxH) 9.7" x 5.5" x 4.5" (24.5 cm x 14.0 cm x 11.4 cm)
Weight 3.5 lb (1.59 kg)
Electrical Requirement 115VAC/60Hz
Current 1.2A (rate)
Fuse 2.5A 250V
Power Cord White, 7 ft (84") / 213.4 cm
Plug 2-prong type
Sound level 55dba
Environment Temperature Operation: 41°F to 104°F (5°C to 40°C)
Storage: 14°F to 158°F (-10°C to 70°C)
Humidity Operation: 30% to 95% RH
Storage: 10% to 95% RH
* Specifications are subject to change without notice.
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 13
LIMITED WARRANTY
GF Health Products Inc. warrants this product to be free from
manufacturing defects in material and workmanship for
its period of warranty that is in accordance with industry
standards. This warranty is extended only to the original
purchaser/consumer or dealer/non-consumer of this new
product and to no other purchaser or transferee.
GF Health Products, Inc. warrants the John Bunn JB0112-164
Nebulizer Compressor and its components to be free from
defects in workmanship and materials as listed below:
Compressor: Five (5) years
Accessories: Six (6) months
The Warranty period for the consumer commences on the
rst date a product is delivered to consumer by seller/dealer.
If the product is rented or leased, the warranty period com-
mences on the invoice date from GF Health Products, Inc.
A copy of the invoice showing date of purchase must be
provided when submitting warranty claims. When proof
of purchase date is not provided, warranty coverage shall
commence upon GF Health Products, Inc.’s invoice date to
the dealer/purchaser.
If within the warranty period, the product or component part
is proven to GF Health Products, Inc.’s satisfaction to be defec-
tive, GF Health Products, Inc. shall provide, at its option, one
of the following: (1) repair or replacement of any defective or
nonconforming part or product or (2) a credit and/or refund
of the original selling price. GF HEALTH PRODUCTS, INC.’S
SOLE OBLIGATION AND YOUR EXCLUSIVE REMEDY UNDER
THIS WARRANTY SHALL BE LIMITED TO SUCH REPAIR, RE-
PLACEMENT, CREDIT AND/OR REFUND. This warranty does
not include any labor charges incurred in replacement part(s)
installation or any associated freight or shipping charges to
the manufacturer.
For warranty service, please contact the authorized autho-
rized distributor from whom you acquired your GF Health
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 14
Products, Inc. product. Upon receiving notice of an alleged
defect in a product, GF Health Products, Inc. will issue a return
authorization. The defective product or part(s) must then be
returned, at the purchaser’s cost, for warranty inspection
using the serial number as identication (or, if the product is
not serialized, lot number and date code) within thirty (30)
days of return authorization issue date. In the event you do
not receive satisfactory warranty service, please contact GF
Health Products, Inc. at the address below. DO NOT return
products to our factory without prior authorization.
LIMITATIONS AND EXCLUSIONS: The foregoing warranty
excludes consumables, such as lters and tubing, as these re-
quire routine maintenance. The foregoing warranty shall not
apply to serial numbered products if the serial number has
been removed or defaced. Products subjected to negligence,
abuse, misuse, improper operation, improper maintenance,
improper cleaning, improper storage, or damages beyond
GF Health Products, Inc.’s control are not covered by this war-
ranty, and that evaluation shall be solely determined by GF
Health Products, Inc. This warranty shall not apply to prob-
lems arising from normal wear and tear or failure to follow
instructions. The warranty shall also not apply to products
modied without GF Health Products, Inc.’s express written
consent; nor shall it apply if parts not manufactured by GF
Health Products, Inc., or if parts not complying with original
equipment specications are added to GF Health Products, Inc.
products, or if the product or part is serviced by an entity
not authorized by GF Health Products, Inc.
THE FOREGOING WARRANTY IS EXCLUSIVE
AND IN LIEU OF ALL OTHER EXPRESS WARRAN-
TIES AND IMPLIED WARRANTIES, INCLUDING
BUT NOT LIMITED TO THE IMPLIED WARRAN-
TIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, AND SHALL
NOT EXTEND BEYOND THE DURATION OF
THE EXPRESS WARRANTY PROVIDED HEREIN,
John Bunn Neb-u-Tyke RR Train Nebulizer Compressor 15
AND THE REMEDY FOR VIOLATIONS OF ANY
IMPLIED WARRANTY SHALL BE LIMITED TO
THE REPAIR, REPLACEMENT, CREDIT AND/OR
REFUND OF THE DEFECTIVE PRODUCT OR
PART PURSUANT TO THE TERMS CONTAINED
HEREIN. GF HEALTH PRODUCTS, INC. SHALL
NOT BE LIABLE FOR ANY CONSEQUENTIAL OR
INCIDENTAL DAMAGES WHATSOEVER.
This warranty gives you specic legal rights and you may also
have other legal rights which vary from state to state (prov-
ince to province). Some states (provinces) do not allow the
exclusion or limitation of incidental or consequential damage,
or limitation on how long an implied warranty lasts, so the
above exclusion and limitations may not apply to you.
This warranty contains the entire agreement between the
parties and supersedes any prior, contrary or additional
representations or understandings, whether oral or written,
concerning our warranty policy.
GF Health Products, Inc. (“Graham-Field”)
2935 Northeast Parkway
Atlanta, GA 30360
Tel 800-347-5678, Fax 800-726-0601
USA Corporate Headquarters:
GF Health Products, Inc.
2935 Northeast Parkway
Atlanta, Georgia 30360
telephone: 800-347-5678, 770-447-1609
fax: 800-726-0601, 678-291-3232
www.grahameld.com
© 2009 GF Health Products, Inc.
JB0112-164-INS-LAB-RevB09
Lea antes de operar el nebulizador. Guarde este
manual para referencia en el futuro.
Nota: La más reciente versión de este manual podrá
ser encontrado en www.grahameld.com.
La Ley Federal (USA) restringe este aparato para
ventas por la orden de su médico. Este aparato no
debe ser utilizado si el operador no ha sido adiestrado
por profesional de cuido de salud cualicado.
Neb-u-Tyke RR Train
Compresor de Nebulizador
Modelo JB0112-164
Manual de Usuario
JB0112-164-INS-LAB-RevB09
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 2
Graham-Field y John Bunn son marcas registradas, y Neb-u-Tyke es una mar-
ca, de GF Health Products, Inc.
Embalaje, garantías, productos y especicaciones son sujetos a cambiar sin
aviso.
GF Health Products, Inc. no es responsable por errores tipográcos.
CONTENIDOS
INTRODUCCIÓN ................................................................................................................... 3
USO DEL COMPRESOR DE NEBULIZADOR ............................................................. 3
SÍMBOLOS ................................................................................................................... 3
DIRECTIVAS IMPORTANTES DE SEGURIDAD ................................................................. 4
DESCRIPCIÓN DEL PRODUCTO ........................................................................................ 6
CARACTERÍSTICAS Y COMPONENTES .................................................................... 6
ENSAMBLAJE ...................................................................................................................... 7
OPERACIÓN ......................................................................................................................... 8
SEGURIDAD EN CASO DE SOBRECARGA ............................................................... 9
MANTENIMIENTO ............................................................................................................... 9
LIMPIEZA DE LA CARCASA DEL COMPRESOR....................................................... 9
LIMPIEZA DE LA TAZA DEL NEBULIZADOR ........................................................... 10
INSTRUCCIONES PARA EL CAMBIO DEL FILTRO DE AIRE ................................. 10
ALMACENAJE ............................................................................................................11
DETECTANDO PROBLEMAS .............................................................................................11
ESPECIFICACIONES ......................................................................................................... 12
GARANTÍA .......................................................................................................................... 13
Este producto ha sido examinado y aprobado con los siguientes
estándares:
UL1431
EN 60601-1
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 3
INTRODUCCIÓN
Este manual del usuario contiene información importante
y precauciones de seguridad para el John Bunn Neb-u-
Tyke RR Train Compresor de Nebulizador. Antes de usar
su Compresor de Nebulizador, favor de leer y entender el
manual de usuario. Tome nota especial en todas las pre-
cauciones marcadas PELIGRO y ADVERTENCIA. Guarde
este manual de usuario para referencia en el futuro.
Uso del Compresor de Nebulizador
El Neb-u-Tyke RR Train Compresor de Nebulizador es dise-
ñado para proveer una fuente de aire comprimido para la
terapia de aerosol. Se usa en conjunto con un nebulizador
de chorro (neumático) para producir aerosoles de medica-
mento para inhalación por pacientes adultos y pediátricos
con síntomas respiratorios.
Indicaciones para terapia incluye asma, bronquitis cróni-
ca, infección de la zona superior respiratorio, enfermedad
pulmonar obstructiva crónica y otros desordenes que va
de acuerdo con la receta de su médico. No debe usar este
producto por cualquier otro propósito, que lo descrito
arriba. Este aparato puede ser usado con pacientes adul-
tos y pediátricos con la receta de su médico.
Símbolos
O Apagado
I Encendido
~ Corriente alternando
IPX0 El equipo no tiene protección contra sumergiendo en agua
Atención (lea las instrucciones)
II Clase II (no aplicable para UL1431)
BF: Este producto está en concordancia con el grado de protección sobre el
riesgo de descarga eléctrica por equipo de tipo BF (no aplicable por UL1431).
Disposición de Equipo Eléctrico y Electrónico (WEEE): Este producto no debe ser tratado
como residuos domésticos, pero sometidos a un sitio de colección para reciclaje de equipo
eléctrico y electrónico. Para más información detallada sobre el reciclaje de este producto,
llame a su oficina de cuidad local, un servicio de disposición de residuos domésticos o a su
distribuidor autorizado de Graham-Field de donde compró este producto.
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 4
DIRECTIVAS IMPORTANTES DE SEGURIDAD
Peligro: Indica una situación de peligro o una practica in-
segura que, si no es evitada, resultará en muerte o heridas
serias a la persona.
ADVERTENCIA: Indica una situación de peligro o una
practica insegura que, si no es evitada, puede resultar en
muerte o heridas serias a la persona.
sPrecaución: Indica una situación de peligro o una prac-
tica insegura que, si no es evitada, puede resultar en
herida leve a la persona o daño al producto/propiedad.
Aviso: Proporciona recomendaciones para la aplicación y
otra información útil para asegurar que obtengas lo más que
pueda del producto.
LEE TODAS LAS INSTRUCCIONES ANTES DE UTILIZAR
PELIGRO: para reducir el riesgo de electrocución.
1. Siempre debe desconectar este producto inmediatamente
después de usar.
2. No debe usar durante el baño, lavando platos, y cerca de
cualquier fuente de agua.
3. No posicionar o almacenar donde pueda caer a la bañera
o al lava manos.
4. No debe introducir en agua u otro liquido. No debe reco-
ger producto sumergido en agua. Desconecte inmediata-
mente.
ADVERTENCIA: Para reducir el riesgo de quemadura, elec-
trocución, fuego o heridas a la persona.
1. Este producto nunca debería ser desatendido mientras
esté conectado.
2. Este producto contiene piezas pequeñas que presenta
riesgos de asxia para niños, y la manga puede presentar
riesgo de estrangulación. Supervisión cercana es necesa-
ria cuando este producto esté utilizado cerca de niños o
personas con impedimentos.
3. Niños menores de 3 años, y cualquier paciente quien no
puede usar la boquilla correctamente bajo supervisión,
debe usar la máscara.
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 5
4. Utilice este producto solamente como indicado en el ma-
nual de usuario. No utilice aditamentos o accesorios no
recomendados por GF Health Products, Inc.
5. Nunca utilice este producto si
a. el enchufe o el cable está dañado
b. no funciona adecuadamente
c. ha sufrido caída o daño
d. ha sido mojado o sumergido en agua
Devuelve este producto al centro de servicio para examen
y/o arreglos.
6. Mantenga el cable lejos de supercies calientes.
7. Nunca obstruya entradas de aire del producto o utilice
en una supercie suave tal como cama o sillón donde las
entradas del aire pueden ser bloqueadas. Mantenga las
entradas libres de pelusa, cabello, o materiales de este
tipo.
8. Nunca inserte objetos en cualquier entrada o manga.
9. Nunca utilice soñoliento o dormido.
10. No utilice al aire libre, ni opere donde se utilicen produc-
tos de aerosol.
11. No utilice en presencia de anestesia, oxígeno, oxido
nítrico, o cualquier gas inamable mientras estos estén
siendo administrado. Este aparato no tiene protección AP
o APG.
12. Conecte este producto solamente en un enchufe de pared
correcto.
13. Este aparato tiene un enchufe polarizado (un aspa es más
ancha que la otra). Para reducir el riesgo de electrocución,
este enchufe es diseñado para poder ser posicionado de
una sola manera en una toma eléctrica polarizada. Si el
enchufe no entre completamente en la toma, invierta el
enchufe. Si no funciona de este modo, contacte un elec-
tricista cualicado. No modique el enchufe de ninguna
manera.
14. Desconecte el aparato antes de llenar el nebulizador.
15. Este aparato no utiliza aceite. No lubrique.
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 6
16. No debe remover el nebulizador de chorro cuando el apa-
rato está operando.
17. No debe dejar medicamento en el nebulizador cuando no
esté en uso.
18. Use el nebulizador por periodos: el periodo de operación
máximo es 30 minutos. El nebulizador no debe ser usado
por 30 minutos entre usos.
19. La boquilla y las máscaras son para uso de una sola per-
sona; para evitar infección no debe compartirlos.
DESCRIPCIÓN DEL PRODUCTO
Características y componentes
Por favor de tomar nota de las características y los compo-
nentes del nebulizador descritos en la ilustración abajo:
manga de reserva
conector del
enchufe de aire
tapa del filtro
interruptor de ON/OFF
máscara adulta
taza del nebulizador
boquilla
manga
adaptador T
máscara pediátrica
Neb-u-Tyke RR Train
Compresor
de Nebulizador
Nota: RR Train piezas reemplazadas están disponibles en
www.grahamfield.com o de su distribuidor autorizado de
Graham-Field.
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 7
ENSAMBLAJE
Aviso: Antes de operación inicial, limpie la taza del nebuli-
zador siguiendo las instrucciones escritos en la sección Man-
tenimiento/Limpieza de la Taza del Nebulizador.
ADVERTENCIA: Antes de conectar el cordón de electri-
cidad, asegure que el interruptor de ON/OFF está en la
posición OFF.
El enchufe también sirve para desconectar el aparato.
1. Antes de uso, examine el compresor y taza de nebuliza-
dor para daño; reemplace si es necesario.
2. Posicione el aparato en una supercie horizontal para
que los controles estén con fácil acceso. No debe usar
este aparato en el piso.
3. Remueva la tapa de la taza del nebulizador.
4. Inserte medicamento prescrito por su médico.
5. Reúne taza y tapa.
6. Si usa la boquilla para el tratamiento,
proceda al paso 7. Si usa la scara,
instale la parte inferior de la scara
directamente sobre la tapa de la taza
del nebulizador como demostrado a
la derecha, entonces proceda al paso
9.
7. Conecte la boquilla a la parte gran-
de del adaptador T.
ensamblaje de
taza y tapa
tapa
taza
instale la máscara
en la tapa
máscara
tapa
ensamblaje de
adaptador T
y boquilla
adaptador T
boquilla
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 8
Aviso: La manga de reserva, en la ilustración superior del
manual, es como un tanque de retención para reducir la
cantidad de medicamento perdido durante tratamiento. Es
opcional. Si desea usar la manga de reserva, posicione en la
parte inferior del adaptador T.
8. Instale el adaptador T sobre la
tapa de la taza del nebulizador.
9. Conecte la manga al adaptador a la
parte inferior de la taza nebulizador.
10. Conecte la otra parte de la manga
al conector de mango del compresor.
ADVERTENCIA: Antes de uso, verique que todas las
piezas están conectados correctamente. Uso de un nebu-
lizador armado incorrectamente puede disminuir o impe-
dir reparto adecuado de medicamento y la efectividad del
tratamiento.
OPERACIÓN
sPrecaución: El Neb-u-Tyke RR Train Compresor de
Nebulizador está diseñado para uso solamente por
periodos. No debe operarlo continuamente por más de
30 minutos en un uso sin apagarlo y dejar que se enfríe
por lo menos 30 minutos.
1. Asegurase que el interruptor eléctrico esté en la posi-
ción “OFF”.
2. Conecte el cordón eléctrico en la toma ectrica apropiada.
3. Encienda el compresor posicionando el interruptor a ON.
4. Acomode la boquilla del nebulizador entre los dientes y
cierre la boca (o instale la máscara en la cara).
5. Cuando el aerosol empiece a uir, necesita inhalar profun-
damente y despacio a tras de la boquilla o la scara.
ADVERTENCIA: Nunca debe usar el nebulizador con un
inyector tapado. Si el inyector está tapado, la nube de aero-
sol será reducido, cambiado o parado, que puede diminuir
o eliminar la efectividad del tratamiento. Si se tapa, reem-
place el nebulizador.
instale adaptador T
en tapa de la taza
adaptador T
taza
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 9
Aviso: Si el tratamiento necesita ser interruptado, posicione
el interruptor a la posición OFF.
6. Cuando el tratamiento haya terminado, apague el com-
presor posicionando el interruptor en la posición OFF.
7. Desenchufe el aparato de la toma eléctrica.
8. Desconecte el nebulizador del mango.
9. Limpie el nebulizador siguiendo las instrucciones escri-
tos en la sección Mantenimiento/Limpieza de la Taza
del Nebulizador.
Seguridad en caso de sobrecarga
Aviso: No debe exceder más de 30 minutos de operación con-
tinuo.
1. Este compresor contiene un dispositivo de protección
termal. Si el motor comienza a sobrecalentarse, se
apagará automáticamente. Si esto ocurre, posicione el
interruptor a la posición OFF y permita que el motor se
enfrié por 30 minutos antes de recomenzar el compre-
sor.
2. Si el protector apaga el motor frecuentemente, podría
tener una situación de voltaje inestable.
3. Si el aparato se apaga y no se enciende, puede ser necesa-
rio reemplazarlo. Llame a su proveedor inmediatamente.
MANTENIMIENTO
Limpieza de la Carcasa del Compresor
ADVERTENCIA: Riesgo de electrocución. No remueve
carcasa externa de este aparato. Todo desensamblaje y
mantenimiento de este aparato debe ser realizado por un
técnico de servicio cualicado.
ADVERTENCIA: Este aparato no necesita aceite. No lubri-
que piezas internas.
ADVERTENCIA: Desenchufe el aparato antes de limpiar. No
sumerja bajo agua.
Frote con un paño húmedo cada semana. No utilice deter-
gentes en polvo o abrasivos que pueden dañar la carcasa.
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 10
Limpieza de la Taza del Nebulizador
Todas las piezas del nebulizador desechable, excepto la
manga, deben ser limpiados después de cada uso. Si su
médico le da un procedimiento especica de limpieza, siga
ese procedimiento.
ADVERTENCIA: Para prevenir riesgo de infección causado
por medicamento contaminado, la limpieza del nebulizador
se recomienda después de cada tratamiento.
1. Después de cado uso, desensamble la taza del nebuliza-
dor, el adaptador T y la boquilla completamente. Lave
todas las piezas en agua tibia con jabón y enjuague bien.
2. A diario, después del paso anterior, remoje los compo-
nentes del nebulizador en una solución consistiendo
de una parte agua y una parte vinagre por 30 minutos,
seguido por un enjuague con agua tibia.
Instrucciones para el cambio del ltro de aire
Aviso: Cambie el filtro cada 30 días o cuando el filtro cam-
bia color. Filtros adicionales pueden ser comprados en
www.grahamfield.com o de su distribuidor autorizado de
Graham-Field.
1. Remueva la tapa del ltro de aire localizado al lado del
interruptor ON/OFF.
2. Remueva el ltro sucio con un objeto punzante.
3. Reemplace el ltro nuevo.
4. Reemplace la tapa del ltro.
sPrecaución: No utilice algodón o cualquier material
como filtro.
sPrecaución: No lave o limpie el filtro.
sPrecaución: No reutilice el filtro. No opere sin filtro. El
compresor puede ser dañado por este uso.
sPrecaución: El kit del nebulizador desechable es para
uso solamente de una persona.
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 11
Almacenaje
Mantenga el aparato y los accesorios secos. Evite sol direc-
tamente.
DETECTANDO PROBLEMAS
Si su Neb-u-Tyke RR Train Compresor de Nebulizador falla,
consulte a la guía de Detectando Problemas debajo. Si el
problema continua, llame a su distribuidor autorizado de
Graham-Field.
Problema Causa y Solución
El aparato no
funciona
Verifique si el enchufe está conectado correctamente en la toma
eléctrica apropiada.
Cuando el aparato ha estado corriendo continuamente por más de 30
minutos, el protector termal interno puede ser activado para que el
aparato se enfríe por 30 minutos, antes del próximo uso.
Nebulización es
débil
Verifique que tiene el voltaje eléctrico apropiado.
Verifique la manga para bloqueos o escapes de aire en la conexión al
compresor o la taza de nebulizador, reemplace si es necesario.
Verifique que la taza del nebulizador está armado bien y no dañado. Si
hay daño, reemplace si es necesario.
Verifique si el filtro está sucio, reemplace el filtro.
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 12
ESPECIFICACIONES *
Especicación Descripción
Presión Máxima del Com-
presor
32.5 PSI
Flujo Máximo Aproximadamente 10 LPM
Tasa de Nebulización 0.33 ml/min
Tamaño de partícula .5 - 5 microns
Capacidad 5 ml
Filtro Esponja
Dimensión (LxWxH) 9.7" x 5.5" x 4.5" (24.5 cm x 14.0 cm x 11.4 cm)
Peso 3.5 lb (1.59 kg)
Requísito Eléctrico 115VAC/60Hz
Corriente 1.2A (tasa)
Capacidad de Fusible 2.5A 250V
Cordón Eléctrico Blanco, 7 ft (84") / 213.4 cm
Enchufe De tipo de 2 Aspa
Nivel de sonido 55dba
Ambiente Temperatura Operación: 41°F a 104°F (5°C to 40°C)
Almacenaje: 14°F to 158°F (-10°C to 70°C)
Humedad Operación: 30% a 95% RH
Almacenaje: 10% a 95% RH
* Especificaciones son sujetos a cambiar sin aviso.
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 13
GARANTÍA
GF Health Products, Inc. garantiza que este producto está libre
de defectos materiales y de mano de obra por el periodo cu-
bierto por la garantía, que está en acorde con los estándares
de la industria. Esta garantía extiende al comprador/consu-
midor original o el distribuidor autorizado/no consumidor
de este producto y no a ninguno otro.
GF Health Products, Inc. garantiza el John Bunn JB0112-164 Com-
presor Nebulizador y sus componentes a estar libre de defec-
tos de materiales o mano de obra según listado debajo:
Compresor: Cinco (5) Años
Accesorios: Seis (6) Meses
El periodo de garantía comienza en el primer día que el pro-
ducto se entrega al consumidor por el agente distribuidor
autorizado. Si el producto es alquilado o arrendado el periodo
de garantía comienza el día de factura de GF Health Products,
Inc. Una copia de la factura, indicando la fecha compra, debe
ser suministrada cuando solicite servicio cubierto bajo la ga-
rantía. Cuando la fecha de compra no sea provista, el periodo
de garantía comenzará en la fecha que GF Health Products,
Inc. le haya facturado al agente distribuidor autorizado.
Durante el periodo de garantía, si el producto o componente
es encontrado por GF Health Products, Inc. de estar defectuo-
so, GF Health Products, Inc. proveerá a su discreción uno de
los siguientes: (1) reparar o reemplazar cualquier pieza o
producto no conforme o defectuoso (2) a proveer un crédito
o reembolso de precio de venta original. La única obligación
GF Health Products, Inc., y su remedio exclusivo bajo los tér-
minos de esta garantía se limita al reparo, cambio, crédito o
reembolso. Esta garantía no incluye ningún cargo de labor,
incurrido en el reemplazo de piezas, instalación o cargos
asociados a transportación o ete al manufacturero.
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 14
Para servicio de garantía, favor de contactar su distribuidor
autorizado al que le compró su producto GF Health Products,
Inc. Tan pronto como GF Health Products, Inc. reciba la noti-
cación de alegado defecto, esta procesará una autorización
de retorno. Los productos o las piezas defectuosos deberán
ser devueltas y el costo de transporte, cubierto por el com-
prador, para una inspección de garantía. Producto debeser
identicados con el número de serie y devuelto a GF Health
Products, Inc. (de no tener número de serie, utilice número
de lote o número de fecha) durante un periodo de trente (30)
días luego de la fecha de emisión de la autorización de retor-
no. En caso que usted no haya recibido servicio de garantía
satisfactorio, por favor contacte GF Health Products, Inc. a la
dirección debajo. No devuelva producto a nuestra fábrica
sin autorización previa.
Limitaciones y exclusiones: La garantía anterior excluye
consumibles, como ltros y tubería, ya que estos requieren
mantenimiento de rutina. La garantía precedente no aplicará
a productos con número de serie, si el número de serie ha sido
removido o desgurado. Productos sometidos a negligencia,
abuso, mal uso, operación impropia, mantenimiento impro-
pio, almacenaje impropio o daños más allá del control de GF
Health Products, Inc. no están cubiertos por esta garantía y la
evaluación de estos sedeterminada por GF Health Products,
Inc. Esta garantía no aplicará a problemas de desgaste que
surjan por operación normal o por falla causada por no seguir
instrucciones de uso. La garantía no aplicará a productos
modicados sin la aprobación escrita de GF Health Products,
Inc., ni aplicará, si partes no manufacturadas por GF Health
Products, Inc. han sido usadas con el producto o si producto
y/o piezas han recibido mantenimiento por entidades no
autorizadas por GF Health Products, Inc.
LA GARANTÍA PRECEDENTE ES EXCLUSIVA Y
PRECEDE OTRAS GARANTÍAS O GARANTÍAS
IMPLÍCITAS, INCLUYENDO PERO NO LIMITADAS
A GARANTÍAS DE MERCADEABILIDAD O APTI-
John Bunn Neb-u-Tyke RR Train Compresor de Nebulizador 15
TUD PARA UN PROPÓSITO PARTICULAR. LA
GARANTÍA NO SE EXTENDERÁ MÁS ALLÁ DEL
PERIODO EXPRESADO ANTERIORMENTE Y EL
REMEDIO PARA VIOLACIONES ESTARÁ LIMITA-
DO AL REEMPLAZO, ARREGLO, OTORGACIÓN
DE CRÉDITO O REEMBOLSO DEL PRECIO DE
COMPRA. GF HEALTH PRODUCTS, INC. NO SE
RESPONSABLE DE DAÑOS CONSECUENTES O
INCIDENTALES.
Esta garantía le da derechos legales especícos, usted tendrá
otros derechos legales que pueden variar de estado a estado
(de provincia a provincia). Algunos estados o provincias no
permiten la exclusión o limitación de daños consecuentes
o incidentales o a limitaciones en cuanto a la duración de
la garantía implícita. Así que las exclusiones o limitaciones
puede que no le apliquen a usted.
Esta garantía contiene el acuerdo entero entre las partes y
supersede cualquier acuerdo contrario anterior o represen-
taciones o entendimientos, orales o escritos concerniente a
la política de garantía.
GF Health Products, Inc. (“Graham-Field”)
2935 Northeast Parkway
Atlanta, GA 30360
Tel 800-347-5678, Fax 800-726-0601
USA Jefaturas Corporativas:
GF Health Products, Inc.
2935 Northeast Parkway
Atlanta, Georgia 30360
tel: 800-347-5678, 770-447-1609
fax: 800-726-0601, 678-291-3232
www.grahameld.com
© 2009 GF Health Products, Inc.
JB0112-164-INS-LAB-RevB09
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Graham Field NEB-U-TYKE JB0112-164 Manual de usuario

Tipo
Manual de usuario
Este manual también es adecuado para