Work-pro MINIDIM RGB (DIN) 2 Manual de usuario

Categoría
Estroboscopios
Tipo
Manual de usuario
Rev. 14.10.01
DESCRIPTION
Congratulations with your purchase of this product.
Check for transport damage.
You should be in possession of the following items:
1 MINIDIM RGB 2
1 Manual
If you discover transport damage after unpacking the equipment,
inform the hauler immediately. Never connect a damaged device. You
BOX CONTENTS
may also contact your supplier.
Output
Oper. temperature
-10
C to +50
C
o
o
6A,Max.
Power Requirement
12~24VDC,6.5AMax.
Terminal Blocks
DMX is an universal binary language used as a form of communication between
intelligent fixtures. Each Dip Switch represents a binary value.
In this mode, the dip-switches 10 & 11 are flipped to OFF and 12 to ON.
The unit needs 3 DMX channel for controlling: Red color is controlled by Channel 1.
Green color is controlled by Channel 2 and Blue color is controlled by Channel 3.
Connection
1 2 3 4 5 6 7 8 9 10
1112
DMX starting address
Dip Switch 1 address equals 1
Dip Switch 2 address equals 2
Dip Switch 3 address equals 4
Dip Switch 4 address equals 8
Dip Switch 5 address equals 16
Dip Switch 6 address equals 32
Dip Switch 7 address equals 64
Dip Switch 8 address equals 128
Dip Switch 9 address equals 256
1,2,4
3,4
1,3,4
2,3,4
1,2,3,4
1
2
1,2
3
1,3
2,3
1,2,3
4
1,4
START
SWITCHES ON SWITCHES ON
2,4
CH#
START
CH#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
..
..
..
..
..
..
ON
OFF
1=
0=
1,2,3,4,5,6,7,8,9
..
For example:
Setting DMX
address for 21.
Flip switches1,3,&5 to the
"ON"position
Dipswitches# Value
1=1
3=4
5=16
=21
1 2 3 4 5 6 7 8 9 10
1112
OPERATION GUIDE
1. DMX Control Mode (DMX addressing)
2.Manual Control Mode
In this mode, the dip-switches 10,12 are flipped to the OFF and 11 to ON.
Flip the dip-switch 1~3 to set the intensity of Red LEDs, dip-switch
Green LEDs and dip-switch 7~9 to set
the intensity of Blue LEDs. Please refer to the following table for
further information.
Red
(SW1~3)
Green
(SW4~6)
Blue
(SW7~9)
Intensity
00157%
10171%
01186%
111100%
001
101
011
111
001
101
011
111
Red
1 2
Green
Blue
3 4 5 6 7 8 9 10
ON
0=OFF
1=
1112
4~6 to set the intensity of
3.Program Mode
In this mode, dip switches 11 & 12 are flipped to OFF and dip 10 to ON. With the dips number 1, 2 & 3, we can select one of five built-in programs. With dips 4, 5 & 6
it is possible to control the general dim level, and using dips 7, 8 & 9, it is possible to control the speed of these programs. See closed tables:
1 2 3 4 5 6 7 8 9 10
1112
1 2
Num. 1 1 0 0
Num. 3 1 1 0
Num. 2 0 1 0
Program
1 2 3
ON
0= OFF
1=
1 2
0 0 0 0
Intensity
5 64
14% 1 0 0
28% 0 1 0
43% 1 1 0
ON
0= OFF
1=
Dimensions
Weight
50(L)x84(W)x28(H)mm
230g
Num. 4 0 0 1
Num. 5 1 0 1
Intensity
57% 0 0 1
71% 1 0 1
86% 0 1 1
100% 1 1 1
8 97
0 0 0 0
Speed
14% 1 0 0
28% 0 1 0
43% 1 1 0
ON
0= OFF
1=
Speed
57% 0 0 1
71% 1 0 1
86% 0 1 1
100% 1 1 1
Program 1: 7 colors changing without fade: Red, Red/Green, Green, Green/Blue, Blue, Blue/Red, White.
Program 2: 6 colors changing with fade: Red, Yellow, Green, Cyan, Blue, Purple.
Program 3: Cyan range. From Blue to Green with tone change.
Program 4: Yellow range: From Red to Green with tone change.
Program 5: Purple range: From Red to Blue with tone change.
Red
(SW1~3)
Green
(SW4~6)
Blue
(SW7~9)
Intensity
0000
10014%
01028%
11043%
000
100
010
110
000
100
010
110
Use the dip switches to set the DMX starting address
Up to 6 A load max. (100 x LED LINE 10 max.)
DMX IN
(from a DMX console)
DMX OUT
(To next MINIDIM RGB 2)
PSU
PSU
24 VDC
24 VDC
6 A max.
6 A max.
Up to 6 A load max. (100 x LED LINE 10 max.)
CONNECTION DIAGRAM (EXAMPLE)
DMX control installation. Two different lines using one MINIDIM RGB 2 in DMX mode for each one. Dips 10, 11 & 12 setup on DMX mode and each MINIDIM RGB 2 with
different DMX starting address in order to make a more individual control.
MINIDIM RGB 2 is a constant voltage driver for RGB LED devices control. It can operate on several modes: Through DMX signal (3 channels), Manual (with intensity
adjustment by dip assignation) or Program (5 built-in programs with intensity and speed control). It allows to connect up to 6 A load on its output.
MINIDIM RGB 2 can be used in a standard DIN rail using the separate accesories for its fixation.
ON
0=OFF
1=
ON
0=OFF
1=
MINIDIM RGB 2
EN
User Manual
12
ON
0=OFF
1=
NOTE: For a better
understanding. the
square in white color
is considered the switch
in all pictures of this
user manual
PSU
PSU
24 VDC
24 VDC
6 A max.
6 A max.
Rev. 14.10.01
DMX es un lenguaje universal binario usado para la
comunicación entre unidades inteligentes. Cada dipswitch representa un valor binario.
DESCRIPCION
Compruebe si se han producido daños durante el transporte.
La unidad debe contener los siguientes elementos:
1 MINIDIM RGB 2
1 Manual
Si descubre daños producidos en la unidad después de desembalarla, consulte con su distribuidor de inmediato y no la conecte.
CONTENIDO
Salida
Temperatura de uso
-10
C a +50
C
o
o
6A,Max.
Alimentación
12~24VDC,6.5AMax.
Terminal Blocks
Conexionado
Dirección de inicio DMX
Dip Switch 1 equivale a 1
Dip Switch 2 equivale a 2
Dip Switch 3 equivale a 4
Dip Switch 4 equivale a 8
Dip Switch 5 equivale a 16
Dip Switch 6 equivale a 32
Dip Switch 7 equivale a 64
Dip Switch 8 equivale a 128
Dip Switch 9 equivale a 256
GUIA DE USO
1. Modo de control DMX (Direccionamiento DMX)
2.Manual Control Mode
(SW1~3) (SW4~6) (SW7~9)
00157%
10171%
01186%
111100%
001
101
011
111
001
101
011
111
3. Modo Program
Num. 1 1 0 0
Num. 3 1 1 0
Num. 2 0 1 0
Programa
1 2 3
ON
0= OFF
1=
1 2
0 0 0 0
Intensidad
5 64
14% 1 0 0
28% 0 1 0
43% 1 1 0
ON
0= OFF
1=
Dimensiones
Peso
54(L)x83(An)x28(Al)mm
230g
Num. 4 0 0 1
Num. 5 1 0 1
Intensidad
57% 0 0 1
71% 1 0 1
86% 0 1 1
100% 1 1 1
8 97
0 0 0 0
Velocidad
14% 1 0 0
28% 0 1 0
43% 1 1 0
ON
0= OFF
1=
Velocidad
57% 0 0 1
71% 1 0 1
86% 0 1 1
100% 1 1 1
Programa 1: 7 colores cambiando sin fade: Rojo, Rojo/Verde, Verde, Verde/Azul, Azul/Rojo, Blanco.
Programa 2: 6 colores cambiando con fade: Rojo, Amarillo, Verde, Cyan, Azúl, Purpura.
Programa 3: Gama Cyan . Desde Azúl a Verde con cambios de tonalidad.
Programa 4: Gama Amarillo: Desde Rojo a Verde con cambios de tonalidad.
Programa 5: Gama Púrpura: Desde Rojo a Azúl con cambios de tonalidad.
Rojo
(SW1~3)
Verde
(SW4~6)
Azúl
(SW7~9)
Intensidad
0000
10014%
01028%
11043%
000
100
010
110
000
100
010
110
Use los dip switches para configurar la dirección de inicio DMX
DMX IN
(fDesde una consola DMX)
DMX OUT
(Al siguiente MINIDIM RGB 2)
DIAGRAMA DE CONEXIONADO (EJEMPLO)
Instalación con control DMX. Dos diferentes líneas usando un MINIDIM RGB 2 en modo DMX en cada una de ellas. Los Dips 10, 11 y 12 configurados en modo DMX y
cada MINIDIM RGB 2 con una dirección de inicio DMX diferente.
Hasta 6 A de carga max. (100 x LED LINE 10 max.)
Hasta 6 A de carga max. (100 x LED LINE 10 max.)
En este modo los dip switches 10 y 12 se configuran a OFF y el 11 a ON. Utilice los dip 1-3 para configurar la intensidad del los LEDs Rojos, los dip 4-6 para configurar
la intensidad de los LEDs Verdes, y los dip 7-9 para configurar la intensidad de los LEDs Azules. Compruebe la tabla adjunta para más información.
Rojo
Verde Azúl
Intensidad
En este modo, los dip 11 y 12 se configuran en OFF y el dip 10 a ON. en los dip 1-3, se selecciona uno de los 5 programas incorporados. Con los dip 4-6, es posible
controlar el nivel de dimmerización general, y usando los dip 7-9, es posible controlar la velocidad de los programas. Ver tabla adjunta.
Por ejemplo:
Configurar la dirección DMX a 21
Pasar los switch 1,3 y 5 a
la posición "ON"
Dipswitches# Valor
1=1
3=4
5=16
=21
1,2,4
3,4
1,3,4
2,3,4
1,2,3,4
..
..
..
1,2,3,4,5,6,7,8,9
..
SWITCHES ON
1
2
1,2
3
1,3
2,3
1,2,3
4
1,4
CANAL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
.
.
.
.
.
.
ON
OFF
1=
0=
511
.
.
2,4
CANAL
SWITCHES ON
1 2 3 4 5 6 7 8 9 10
1112
Gracias por la adquisición de este producto.
MINIDIM RGB 2 es un driver de tensión constante para el control de dispositivos LED RGB. Puede funcionar en varios modos: Mediante señal DMX (3 canales de control),
Manual (Con ajuste de la intensidad por asignación de dips) o Program (5 programas incorporados con ajuste de intensidad y velocidad). Permite la conexión de hasta
6 A de carga en su salida.
MINIDIM RGB 2 puede ser utilizado en un carril standard DIN mediante los accesorios de fijación suministrados aparte.
1 2 3 4 5 6 7 8 9 10
1112
Rojo
1 2
Verde
Azul
3 4 5 6 7 8 9 10
ON
0=OFF
1=
1112
1 2 3 4 5 6 7 8 9 10
1112
1 2
ON
0=OFF
1=
ON
0=OFF
1=
ES
Manual de uso
MINIDIM RGB 2
En este modo los dip 10 y 11 se configuran en OFF y el 12 en ON La unidad necesita 3 canales DMX para controlar: Color Rojo se controla con el 1º canal, el color
verde con el 2º canal y el azul con el 3º canal.
12
ON
0=OFF
1=
NOTA: Para una mejor
comprensión, el
rectángulo en color
blanco se considera
el switch en todos los
dibujos de este manual
INIC.INIC.
  • Page 1 1
  • Page 2 2

Work-pro MINIDIM RGB (DIN) 2 Manual de usuario

Categoría
Estroboscopios
Tipo
Manual de usuario

en otros idiomas