Milwaukee M18 FUEl 0885-20 Manual de usuario

Tipo
Manual de usuario
Cat. No. / No de cat.
0885-20
M18™ FUEL™ 3-in-1 BACKPACK VACUUM
ASPIRATEUR DORSAL 3-en-1 M18™ FUEL™
ASPIRADORA DE MOCHILA 3-en-1 M18™ FUEL™
OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
WARNING To reduce the risk of injury, user must read and understand operator's manual.
AVERTISSEMENT An de réduire le risque de blessures, l'utilisateur doit lire et bien
comprendre le manuel.
ADVERTENCIA Para reducir el riesgo de lesiones, el usuario debe leer y entender el manual.
2
3
SYMBOLOGY
Volts
Direct Current
Read operator's manual
Wear eye protection
C
US
UL Listing for Canada and U.S.
SPECIFICATIONS
Cat. No. ..................................................... 0885-20
Volts.............................................................. 18 DC
Battery Type .................................................M18™
Charger Type................................................M18™
Air Volume ..................................................55 CFM
Sealed Suction ...........................................76inH
2
0
Air Performance.................................. 159 air watts
Capacity..............................................1 Gal. (3.8 L)
Recommended Ambient
Operating Temperature ......................0°F to 125°F
Telescoping Extension Wand ............... 14-37-0005
Flexible Hose ........................................ 31-01-0305
Crevice Tool .......................................... 31-01-0310
Floor Tool .............................................. 31-01-0315
Dust Extraction Adapter ........................ 31-01-0320
HEPA Filter ...........................................49-90-1963
9 Foot Accessory Hose......................... 49-90-1964
WORK AREA SAFETY
Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
Do not use in the presence of explosive dust,
liquids or vapors.
Do not use where oxygen or anesthetics are
used.
Do not allow to be used as a toy. Close attention
is necessary when used by or near children.
Use extra care when using on stairs.
ELECTRICAL SAFETY
Do not pick up wet material. Do not use water to
settle dust.
Do not handle battery pack or vacuum with wet
hands.
Store indoors. Do not expose to rain.
PERSONAL SAFETY
STAY ALERT. Watch what you are doing and use
common sense. Do not use vacuum when you are
tired, distracted or under the inuence of drugs,
alcohol or medication causing diminished control.
The operation of a vacuum can result in foreign
objects being blown into eyes, which can result in
eye damage. Always wear safety goggles or glasses
with side shields when operating vacuum.
Wear a dust mask or use an OSHA compliant
dust extraction solution when working in dusty
situations. Dust particles can harm your lungs.
Avoid accidental starting. Ensure the switch is
in the off-position before inserting battery pack.
Inserting battery pack in vacuum that has the switch
on invites accidents.
Do not overreach. Keep proper footing and bal-
ance at all times. This enables better control of the
vacuum in unexpected situations.
Never stand on vacuum or use as a step stool.
Keep hair, loose clothing, ngers, and all parts
of body away from openings and moving parts.
Use only as described in this manual. Use only
manufacturer’s recommended attachments.
USE AND CARE
Do not use without tank and/or lter properly
installed.
Do not use to pick up ammable or combustible
liquids such as gasoline or use in areas where they
may be present.
Do not pick up anything that is burning or smok-
ing such as cigarettes, matches, or hot ashes.
Do not pick up soot, cement, plaster or drywall
dust without lter in place. These are very ne
particles that may affect the performance of the
motor or be exhausted back into the air.
To reduce risk, do not use to vacuum hazard-
ous, toxic or carcinogenic materials, such as
asbestos or pesticide.
Use special care when emptying heavily loaded
tanks.
To avoid spontaneous combustion, empty tank
after each use.
Do not leave vacuum unattended when battery
pack is installed. Remove battery pack when not
in use and before servicing.
Do not put any object into openings. Do not use
with any opening blocked; keep free of dust, lint,
hair, and anything else that may reduce air ow.
Static shocks are possible in dry areas or when
the relative humidity of the air is low. This is
only temporary and does not affect the use of the
vacuum. To reduce the frequency of static shocks,
add moisture to the air with a console or installed
humidier.
Some wood contains preservatives and can be
toxic. Take extra care to prevent inhalation and
skin contact when working with these materials.
Request and follow any safety information available
from your material supplier.
Maintain vacuum. Check for misalignment or
binding of moving parts, breakage of parts and
any other condition that may affect the vacuum's
operation. If damaged, have the vacuum repaired
before use. Many accidents are caused by poorly
maintained tools.
Always use common sense and be cautious
when using tools. It is not possible to anticipate
every situation that could result in a dangerous out-
come. Do not use this tool if you do not understand
these operating instructions or you feel the work is
beyond your capability; contact Milwaukee Tool or
a trained professional for additional information or
training.
Maintain labels and nameplates. These carry
important information. If unreadable or missing,
contact a MILWAUKEE service facility for a free
replacement.
This product is suitable for collection of silica
dust when used in accordance with these in-
structions. To reduce the risk of health hazards
from other vapors or dust, do not vacuum
carcinogenic, toxic or hazardous materials
such as asbestos, arsenic, barium, beryllium, lead,
pesticides or other health endangered materials.
WARNING
Some dust created by
power sanding, sawing,
grinding, drilling, and other construction activities
contains chemicals known to cause cancer, birth
defects or other reproductive harm. Some examples
of these chemicals are:
lead from lead-based paint
crystalline silica from bricks and cement and other
masonry products, and
arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending
on how often you do this type of work. To reduce
your exposure to these chemicals: work in a well
ventilated area, and work with approved safety
equipment, such as those dust masks that are spe-
cially designed to lter out microscopic particles.
The unit is compliant as an objective data
solution of OSHA Standard 29CRF 1926.1153,
assuming it is used in accordance with
MILWAUKEE instructions. Please reference
https://www.osha.gov for further details on compli-
ance methods. Visit https://www.milwaukeetool.
com for an objective data sheet.
BATTERY PACK USE AND CARE
Use vacuum only with specically designated
battery packs. Use of any other battery packs may
create a risk of injury and re.
Turn off all controls before removing battery pack.
Before using the battery pack or charger read
the operator’s manuals, and any labels on the
battery pack, charger and vacuum.
Recharge only with the charger specied by the
manufacturer. A charger that is suitable for one type
of battery pack may create a risk of re when used
with another battery pack.
When battery pack is not in use, keep it away
from other metal objects like paper clips, coins,
keys, nails, screws, or other small metal objects
that can make a connection from one terminal
to another. Shorting the battery terminals together
may cause burns or a re.
Do not use damaged battery pack or vacuum.
If battery pack or vacuum are not working as
they should, have been dropped, damaged, left
outdoors,or dropped into water, return them to a
service center.
SERVICE
Have your power tool serviced by a qualied
repair person using only identical replacement
parts. This will ensure that the safety of the power
tool is maintained.
Never service damaged battery packs. Service
of battery packs should only be performed by the
manufacturer or authorized service providers.
SPECIFIC SAFETY RULES
Before using the vacuum, read this operator’s
manual, your battery pack and charger opera-
tor’s manuals, and all labels on the vacuum,
battery pack, and charger.
Never use vacuum without tank and lter properly
installed. Vacuum will throw dust and debris into the
air.
Never use water to clean lter. Tap clean or blow
dirt off with compressed air. Water will cause lter
to fail.
Wear ear protectors. Exposure to noise can cause
hearing loss.
READ AND SAVE
ALL
INSTRUCTIONS
FOR FUTURE USE
IMPORTANT SAFETY INSTRUCTIONS
WARNING
WHEN USING AN ELECTRICAL VACUUM, TO REDUCE THE
RISK OF FIRE OR INJURY, BASIC PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ ALL INSTRUC-
TIONS BEFORE USING VACUUM. FOR HOUSEHOLD OR COMMERCIAL USE.
BEFORE USING THE VACUUM, READ THIS OPERATOR’S MANUAL, BATTERY
PACK AND CHARGER OPERATOR’S MANUALS, AND ALL LABELS ON THE
VACUUM, BATTERY PACK, AND CHARGER.
4
5
ASSEMBLY
WARNING
To reduce the risk of
injury, always remove
the battery pack before removing the tank.
CAUTION
Keep lter clean. Efciency
of the vacuum is largely
dependent on the lter. A dirty lter will reduce
the air ow and overall efciency of the system.
Do not clean with water. Remove from tank and
tap clean or blow off with compressed air.
Removing/Inserting the Battery
To remove the battery, push in the release buttons
and pull the battery pack away from the tool.
WARNING
Always remove battery
pack before changing
or removing accessories.
To insert the battery, slide the pack into the body
of the tool. Make sure it latches securely into place.
Removing/Installing the Filter
To remove the lter:
Tank release
button
Tank
Filter
Tank
cap
1. Remove the battery pack.
2. Press the tank handle button
and remove the tank from the
vacuum.
3. Pull out tank cap to expose the
lter. Pull the lter out of the
tank.
4. Lift the tank release button and
empty all the dust and debris
from the tank.
5. To clean the lter, tap clean or
blow dirt off with compressed
air. Replace the lter if dam-
aged or suction decreases
(single pack, Cat. No. 49-90-
1963).
NOTE: Never use water to
clean lter.
To install the lter:
1. Place the lter into the top of the tank.
2. Line up the tank cap guides and secure it to the
tank. Place the tank back into the vacuum.
WARNING
Only use accessories
specifically recom-
mended for this tool. Others may be hazardous.
Removing/Installing the Accessories
To install the hose, push the accessory onto the
vacuum inlet. To install the nozzles and extensions,
push the accessory onto the hose end.
To remove, press the accessory clip and pull out.
Storing the Accessories
Each of the accessories can be stored on the
vacuum.
Floor
tool
Telescoping
extension
wand
Telescoping extension
wand:Clip the accessory
onto the extension wand
holder.
Floor tool: Insert the
accessory onto the top of the
telescoping extension wand.
Flexible hose: Insert the
Flexible
hose
accessory onto the vacuum
inlet. Clip onto the hose clip
to secure.
Crevice tool: Hook the accessory onto the crevice
tool rungs located on the lower backpack strap.
Push the nose of the accessory through the lower
rung and strap the top to the upper rung.
Dust extraction adapter: Hook the accessory
onto the dust extraction adapter rung located on
the lower backpack strap.
Crevice
tool
Dust extraction
adapter
Removing/Installing the Backpack Plate
The backpack plate can be removed when mount-
ing the vacuum on a surface or carrying by hand.
To remove the plate, hold down the backpack plate
release button. Pull the bottom end of the plate
away from the vacuum to remove the lower tabs.
Pull down on the plate and away from the vacuum
to remove the upper tabs.
Backpack plate release button
To install the plate, line up and insert the upper
plate tabs into the vacuum. Lift the plate up to align
and insert the lower plate tabs into the vacuum.
Push the tabs in to lock.
FUNCTIONAL
DESCRIPTION
1
2
6
8
11
7
4
10
3
9
12
13
14
16
15
17
5
1. Carrying handle
2. Tank handle button
3. Tank
4. Battery bay
5. Hose clip
6. Vacuum inlet
7. Extension wand holder
8. Top backpack straps
9. Backpack plate
10. Lower backpack strap
Mounting the Vacuum
The vacuum can be hung and mounted to a surface
for ease of use.
To mount the vacuum, remove the backpack plate
according to the "Removing/Installing the Backpack
Plate" instructions. This will expose the mounting
hanger. Pull hanger away from the vacuum, unclip
the hanger straps and hook vacuum onto surface.
Secure by clipping the hanger straps and tightening
to the surface.
Mounting
hanger
Hanger
straps
To unmount the vacuum, unhook the hanger straps.
Pull hanger from the surface and push hanger back
into the vacuum. Reinstall the backpack plate ac-
cording to the "Removing/Installing the Backpack
Plate" instructions.
OPERATION
WARNING
To reduce the risk of re
and injury, do not use
to pick up ammable or combustible materials.
To reduce the risk of injury, wear safety goggles
or glasses with side shields. Empty tank before
use.
Before use, ensure the lter is installed.
CAUTION
Do not carry vacuum by the
tank handle.
Starting, Stopping, and Controlling Speed
Press the Power switch up to 2 to run the vacuum
on High power. Press the Power switch down
to 1 to run the vacuum on Low power. To turn the
vacuum Off, return the Power switch to its home
position.
Using the Vacuum
There are multiple ways to use the vacuum to best
suit your job.
Wearing the vacuum as a backpack. Place
vacuum on body. Secure the tool by strapping in
the top and bottom backpack straps.
Mounting the vacuum on a surface. Remove
the backpack plate according to the "Removing/
Installing the Backpack Plate" instructions. Then
mount the vacuum to the surface according to the
"Mounting the Vacuum" instructions.
Carrying the vacuum in hand. If desired, remove
the backpack plate according to the "Removing/
Installing the Backpack Plate" instructions.
11. Switch
12. Flexible hose
13. Telescoping
extension wand
14. Floor tool
15. Dust extraction
adapter
16. Crevice tool
17. HEPA lter
6
7
Operation
1. Remove ALL dirt and debris found in the tank.
2. Insert battery pack and attach accessories.
3. Press the Power switch to the desired speed.
Begin pick-up.
4. Turn off the vacuum immediately upon completing
a job or when tank is full and ready to be emptied.
NOTE: If suction shuts off, turn off the vacuum
immediately and empty the tank.
5. Remove battery pack.
6. Clean the interior of the tank and accessories
periodically.
Storage
Before storing your vacuum, empty and clean the
tank, lter, and accessories. Remove the battery
pack.
MAINTENANCE
WARNING
To reduce the risk of
injury, always unplug
the charger and remove the battery pack from
the charger or tool before performing any main-
tenance. Never disassemble the tool, battery
pack or charger. Contact a MILWAUKEE service
facility for ALL repairs.
Maintaining Tool
Keep your tool, battery pack and charger in good
repair by adopting a regular maintenance program.
Inspect your tool for issues such as undue noise,
misalignment or binding of moving parts, breakage of
parts, or any other condition that may affect the tool
operation. Return the tool, battery pack, and charger
to a MILWAUKEE service facility for repair. After six
months to one year, depending on use, return the
tool, battery pack and charger to a MILWAUKEE
service facility for inspection.
If the tool does not start or operate at full power with
a fully charged battery pack, clean the contacts on
the battery pack. If the tool still does not work prop-
erly, return the tool, charger and battery pack, to a
MILWAUKEE service facility for repairs.
WARNING
To reduce the risk of
personal injury and
damage, never immerse your tool, battery pack
or charger in liquid or allow a liquid to ow inside
them.
Cleaning
Clean dust and debris from vents. Keep handles
clean, dry and free of oil or grease. Use only mild
soap and a damp cloth to clean, since certain clean-
ing agents and solvents are harmful to plastics and
other insulated parts. Some of these include gasoline,
turpentine, lacquer thinner, paint thinner, chlorinated
cleaning solvents, ammonia and household deter-
gents containing ammonia. Never use ammable or
combustible solvents around tools.
Repairs
For repairs, return the tool, battery pack and charger
to the nearest service center.
ACCESSORIES
WARNING
Use only recommended
accessories. Others
may be hazardous.
For a complete listing of accessories, go online to
www.milwaukeetool.com or contact a distributor.
SERVICE - UNITED STATES
1-800-SAWDUST (1.800.729.3878)
Monday-Friday, 7:00 AM - 6:30 PM CST
or visit www.milwaukeetool.com
Contact Corporate After Sales Service Technical
Support with technical, service/repair, or warranty
questions.
Become a Heavy Duty Club Member at
www.milwaukeetool.com to receive important
notications regarding your tool purchases.
SERVICE - CANADA
Milwaukee Tool (Canada) Ltd
1.800.268.4015
Monday-Friday, 7:00 AM - 4:30 PM CST
or visit www.milwaukeetool.ca
LIMITED WARRANTY
USA & CANADA
Every MILWAUKEE power tool* (see exceptions below) is warranted
to the original purchaser only to be free from defects in material and
workmanship. Subject to certain exceptions, MILWAUKEE will repair
or replace any part on an electric power tool which, after examination,
is determined by MILWAUKEE to be defective in material or workman-
ship for a period of ve (5) years** after the date of purchase unless
otherwise noted. Return of the power tool to a MILWAUKEE factory
Service Center location or MILWAUKEE Authorized Service Station,
freight prepaid and insured, is required. A copy of the proof of purchase
should be included with the return product. This warranty does not
apply to damage that MILWAUKEE determines to be from repairs
made or attempted by anyone other than MILWAUKEE authorized
personnel, misuse, alterations, abuse, normal wear and tear, lack of
maintenance, or accidents.
Normal Wear: Many power tools need periodic parts replacement and
service to achieve best performance. This warranty does not cover
repair when normal use has exhausted the life of a part including,
but not limited to, chucks, brushes, cords, saw shoes, blade clamps,
o-rings, seals, bumpers, driver blades, pistons, strikers, lifters, and
bumper cover washers.
*This warranty does not cover Air Nailers & Staplers; Airless Paint
Sprayer; Cordless Battery Packs; Gasoline Driven Portable Power
Generators; Hand Tools; Hoist – Electric, Lever & Hand Chain; M12™
Heated Gear; Reconditioned Product; and Test & Measurement
Products. There are separate and distinct warranties available for
these products.
**The warranty period for Job Site Radios, M12™ Power Port, M18™
Power Source, Jobsite Fan and Trade Titan™ Industrial Work Carts is
one (1) year from the date of purchase. The warranty period for the
Drain Cleaning Cables is two (2) years from the date of purchase. The
warranty period for the M18™ Compact Heat Gun and the 8 Gallon
Dust Extractor is three (3) years from the date of purchase. The war-
ranty period for the LED in the LED Work Light and the LED Upgrade
Bulb for the Work Light is the lifetime of the product subject to the
limitations above. If during normal use the LED or LED Bulb fails, the
part will be replaced free of charge.
Warranty Registration is not necessary to obtain the applicable war-
ranty on a MILWAUKEE power tool product. The manufacturing date
of the product will be used to determine the warranty period if no proof
of purchase is provided at the time warranty service is requested.
ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT
REMEDIES DESCRIBED HEREIN IS A CONDITION OF THE CON-
TRACT FOR THE PURCHASE OF EVERY MILWAUKEE PRODUCT.
IF YOU DO NOT AGREE TO THIS CONDITION, YOU SHOULD NOT
PURCHASE THE PRODUCT. IN NO EVENT SHALL MILWAUKEE
BE LIABLE FOR ANY INCIDENTAL, SPECIAL, CONSEQUENTIAL
OR PUNITIVE DAMAGES, OR FOR ANY COSTS, ATTORNEY FEES,
EXPENSES, LOSSES OR DELAYS ALLEGED TO BE AS A CONSE-
QUENCE OF ANY DAMAGE TO, FAILURE OF, OR DEFECT IN ANY
PRODUCT INCLUDING, BUT NOT LIMITED TO, ANY CLAIMS FOR
LOSS OF PROFITS. SOME STATES DO NOT ALLOW THE EX-
CLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO YOU. THIS WARRANTY IS EXCLUSIVE AND IN LIEU
OF ALL OTHER EXPRESS WARRANTIES, WRITTEN OR ORAL.
TO THE EXTENT PERMITTED BY LAW, MILWAUKEE DISCLAIMS
ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR USE OR PURPOSE; TO THE EXTENT SUCH
DISCLAIMER IS NOT PERMITTED BY LAW, SUCH IMPLIED WAR-
RANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE
EXPRESS WARRANTY AS DESCRIBED ABOVE. SOME STATES
DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WAR-
RANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO
YOU, THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,
AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM
STATE TO STATE.
This warranty applies to product sold in the U.S.A. and Canada only.
Please consult the ‘Service Center Search’ in the Parts & Service sec-
tion of MILWAUKEE’s website www.milwaukeetool.com or call 1.800.
SAWDUST (1.800.729.3878) to locate your nearest service facility for
warranty and non-warranty service on a Milwaukee electric power tool.
LIMITED WARRANTY - MEXICO,
CENTRAL AMERICA & CARIBBEAN
TECHTRONIC INDUSTRIES' warranty is for 5 years since the original
purchase date.
This warranty card covers any defect in material and workmanship
on this Product.
To make this warranty valid, present this warranty card, sealed/
stamped by the distributor or store where you purchased the product,
to the Authorized Service Center (ASC). Or, if this card has not been
sealed/stamped, present the original proof of purchase to the ASC.
Call toll-free1 01 (800) 030-7777 to nd the nearest ASC, for service,
parts, accessories or components.
Procedure to make this warranty valid
Take the product to the ASC, along with the warranty card sealed/
stamped by the distributor or store where you purchased the product,
and any faulty piece or component will be replaced without cost for
you. We will cover all freight costs relative with this warranty process.
Exceptions
This warranty is not valid in the following situations
a) When the product is used in a different manner from the end-user
guide or instruction manual.
b) When the conditions of use are not normal.
c) When the product was modied or repaired by people not authorized
by TECHTRONIC INDUSTRIES.
Note: If cord set is damaged, it should be replaced by an Authorized
Service Center to avoid electric risks.
SERVICE AND ATTENTION CENTER
Call to 01 (800) 030-7777
IMPORTED AND COMMERCIALIZED BY
TECHTRONIC INDUSTRIES MEXICO, SA DE CV
Av President Masarik #29 piso 7, Col. Polanco V Sección
CP 11560, Deleg. Miguel Hidalgo, CDMX
Model:
Date of Purchase:
Distributor or Store Stamp:
RÈGLES
GÉNÉRALES DE
SÉCURITÉ
LORS
D E
L’UTILISATION D’UN ASPIRATEUR
ELECTRIQUE ET AFIN DE MINIMISER
LE RISQUE D’INCENDIE OU
BLESSURES, IL FAUT TOUJOURS
PRENDRE DES PRECAUTIONS
ELEMENTAIRES, Y COMPRIS CELLES
PRESENTEES CI-DESSOUS : LIRE
TOUTES LES INSTRUCTIONS AVANT
D'UTILISER L’ASPIRATEUR. POUR DES
APPLICATIONS COMMERCIALES OU
RESIDENTIELLES. AVANT D’UTILISER
L’ASPIRATEUR, LIRE LE PRÉSENT
MANUEL D’UTILISATION, LE MANUEL
D’UTILISATION DU BLOC-PILES ET DU
CHARGEUR, AINSI QUE TOUTES LES
ÉTIQUETTES SE TROUVANT SUR
L’ASPIRATEUR, LE BLOC-PILES, ET LE
CHARGEUR.
SÉCURITÉ DU LIEU DE TRAVAIL
Veillez à ce que l’aire de travail soit propre et
bien éclairée. Le désordre et le manque de lumière
favorisent les accidents.
Ne pas utiliser en présence de liquides explosifs
ou de poussière ou vapeurs explosives.
Ne pas utiliser où l'oxygène ou les agents anes-
thésiques sont utilisés.
Cet appareil n’est pas un jouet. Une surveillance
étroite est impérative lorsqu’il est utilisé par des
enfants ou à leur proximité.
Redoubler de prudence lors de l'utilisation dans
des escaliers.
SÉCURITÉ ÉLECTRIQUE
Ne pas aspirer de matériaux humides. Ne pas
utiliser d’eau pour déposer la poussière.
Ne pas manipuler le bloc-pile ou l’aspirateur
avec les mains mouillées.
Entreposer à l’intérieur. Ne pas exposer à la
pluie.
SÉCURITÉ INDIVIDUELLE
• RESTER VIGILANT. Se montrer attentif et faire
preuve de bon sens. Ne pas utiliser l’aspirateur en
cas de fatigue, distraction ou sous l’inuence de
l’alcool, de drogues ou de médicaments causant la
perte de contrôle.
L’utilisation d'un aspirateur peut causer la
projection d’objets en direction du visage et
entraîner des lésions oculaires. Toujours porter
des lunettes de sécurité ou des lunettes avec écrans
latéraux lors de l’utilisation de l’aspirateur.
Porter un masque anti-poussière ou utiliser une
solution d'extraction de poussière conforme aux
normes de l'OSHA pendant que vous travaillez
dans des circonstances poussièreuses. Les par-
ticules de poussière peuvent nuire vos poumons.
8
9
l'utilisation. Beaucoup d'accidents sont causés par
des outils mal entretenus.
Toujours faire preuve de bons sens et procéder
avec prudence lors de l’utilisation d’outils. C’est
impossible de prévoir toutes les situations dont le
résultat est dangereux. Ne pas utiliser cet outil si vous
ne comprenez pas ces instructions d’opération ou si
vous pensez que le travail dépasse votre capacité ;
veuillez contacter Milwaukee Tool ou un professionnel
formé pour recevoir plus d’information ou formation.
Maintenir en état les étiquettes et les plaques
signalétiques. Des informations importantes y
gurent. Si elles sont illisibles ou manquantes,
contacter un centre de service et d’entretien
MILWAUKEE pour un remplacement gratuit.
Ce produit convient à la collecte de la poussière
de silice lorsqu'il est utilisé conformément à ces
instructions.
An de réduire les risques pour la
santé issus de
autres
vapeurs ou de poussières,
ne pas aspirer de matières toxiques, cancérigènes
ou autres matières dangereuses comme l'amiante,
l'arsenic, le baryum, le béryllium, le plomb, les pesti-
cides ou autres matières pouvant mettre en danger
la santé.
La poussière dégagée par certains matériaux lors
du ponçage, sciage, meulage, perçage et autres
opérations de construction contient des produits
chimiques reconnus pour causer le cancer, des
malformations congénitales ou des lésions de
l’appareil reproducteur. Voici certains exemples de
ces produits chimiques :
le plomb contenu dans la peinture au plomb,
la silice cristalline contenue dans les briques, le
ciment et d'autres produits de maçonnerie, et
l'arsenic et le chrome contenus dans le bois de
construction traité par produits chimiques.
Le risque présenté par l’exposition à ces produits va-
rie en fonction de la fréquence de ce type de travail.
Pour réduire l’exposition à ces produits chimiques
: travailler dans un endroit bien aéré et utiliser des
équipements de sécurité approuvés tels que les
masques anti-poussière spécialement conçus pour
ltrer les particules microscopiques.
• L’unité est conforme, comme une solution de résu-
ltats objectifs, à la norme OSHA 29CRF 1926.1153
lorsqu’elle est utilisée sans un aspirateur de
poussière, en supposant qu’elle est utilisé selon
les instructions de MILWAUKEE. Veuillez consulter
le site d’Internet https://www.osha.gov pour en
savoir plus à propos des méthodes de conformité.
Veuillez consulter https://www.milwaukeetool.com
pour consulter les ches techniques complètes.
UTILISATION ET ENTRETIEN
DE LA BATTERIE
N’utiliser l’aspirateur qu’avec des bloc-piles
recommandés. L’utilisation de tout autre bloc-piles
peut créer un risque de blessures et d’incendie.
Arrêter toutes les commandes avant de retirer
le bloc-piles.
Pour réduire le risque de choc électrique, ne pas
utiliser sur une surface mouillée. Ne pas exposer
l’appareil à la pluie. Entreposer à l’intérieur.
Avant d’utiliser le bloc-pile ou le chargeur, lire
les manuels d’utilisation et toutes les étiquettes
sur le bloc-piles, le chargeur et l’aspirateur.
Pour recharger le bloc-piles, utiliser seulement
le chargeur spécié par le fabricant. Un chargeur
pouvant convenir à un type de bloc-piles peut en-
traîner un risque d’incendie lorsqu’il est utilisé avec
un autre type de bloc-piles.
Lorsque le bloc-piles n’est pas utilisé, le tenir
éloigné des objets en métal tels que les trom-
bones, les pièces de monnaie, les clés, les clous,
les vis ou d’autres petits objets métalliques
qui pourraient connecter les bornes. Le court-
circuitage des bornes d’une batterie peut entraîner
des brûlures ou un incendie.
Ne pas utiliser un bloc-pile ou un aspirateur
endommagé. Si le bloc-piles ou l’aspirateur ne
fonctionne pas correctement, s’ils ont été tombés
par terre, s’ils sont endommagés, s’ils ont été lais-
sés à l’extérieur ou s’ils sont tombés dans l’eau,
retournez-les au centre de service.
ENTRETIEN
Les réparations de l’outil électrique doivent être con-
ées à un technicien qualié, utilisant exclusivement
des pièces identiques à celles d’origine. Le maintien
de la sûreté de l’outil électrique sera ainsi assuré.
Ne jamais effectuer la réparation d’un bloc-piles
endommagé. La réparation du bloc-piles doit être
réalisée par le fabricant ou les fournisseurs de service
agréés uniquement.
REGLAS ESPECIFICAS
DE SEGURIDAD
Avant d’utiliser l’aspirateur, lire le présent
manuel d’utilisation, le manuel d’utilisation du
bloc-piles et du chargeur, ainsi que toutes les
étiquettes se trouvant sur l’aspirateur, le bloc-
piles et le chargeur.
Ne jamais utiliser l'aspirateur sans avoir le réser-
voir et le ltre correctement installés. L’aspirateur
éjectera de la poussière et du débris dans l’air.
Ne jamais utiliser de l’eau pour nettoyer le ltre.
Nettoyer en frappant ou en soufant la saleté
avec de l’air comprimé. L’eau provoquera des
échecs dans le ltre.
Porter des protecteurs d’oreille. L’exposition au
bruit peut entraîner une perte auditive.
LIRE TOUTES LES
INSTRUCTIONS ET
LES CONSERVER À
DES FINS DE
RÉFÉRENCE
ULTÉRIEURE
DESCRIPTION
FONCTIONNELLE
1
2
6
8
11
7
4
10
3
9
12
13
14
16
15
17
5
1. Poignée de transport
2. Bouton d'activation du
réservoir
3. Réservoir
4. Compartiment des piles
5. Clip de tuyau
6. Entrée de l’aspirateur
7. Support prolongateur de
la lance
8. Sangles supérieures du
sac à dos
9. Plaque de sac à dos
Éviter les démarrages accidentels. S'assurer
que l’interrupteur est en position d’arrêt avant
d’insérer le bloc-piles. L’insertion du bloc-piles
quand l’interrupteur de l’aspirateur est en position
de marche augmente le risque d’accidents.
Ne pas travailler hors de portée. Toujours se te-
nir bien campé et en équilibre. Une bonne stabilité
procure un meilleur contrôle de l’aspirateur en cas
d’imprévus.
Ne jamais monter sur l’aspirateur ou s’en servir
comme marchepied.
Garder les cheveux, les vêtements amples, les
doigts ainsi que toutes les parties du corps à l’écart
des ouvertures et des pièces en mouvement.
Utiliser exclusivement selon les instructions de
ce manuel. Utiliser exclusivement les accessoires
recommandés par le fabricant.
UTILISATION ET ENTRETIEN
DE L’OUTIL ÉLECTRIQUE
Ne pas utiliser l'aspirateur sans avoir le réservoir
et/ou le ltre correctement installés.
Ne pas utiliser l’appareil pour ramasser des
liquides inammables ou combustibles tels que
l’essence, ou dans des environnements où il est
possible de retrouver ce type de liquide.
Ne pas aspirer d’éléments qui brûlent ou qui
fument comme des cigarettes, des allumettes ou
des cendres chaudes.
Ne pas aspirer de la suie, du ciment, du plâtre ou
de la poussière de cloison sèche sans le ltre en
place. Il y a des particules très nes qui peuvent affect-
er le rendement du moteur ou s’échapper dans l’air.
An de minimiser les risques, ne pas l’utiliser
pour aspirer de matériaux dangereux, toxiques
ou carcinogéniques tels que l’amiante ou les
pesticides.
Faire preuve d’une extrême prudence en vidant
les réservoirs fortement chargés.
Pour prévenir la combustion spontanée, vider le
réservoir de poussière après chaque utilisation.
• Ne pa
s laisser l’aspirateur sans surveillance lorsque
le bloc-pile est installé. Retirer le bloc-pile lorsque ce-
lui-ci n’est pas utilisé et avant de procéder à son entretien.
Ne placer aucun objet dans les ouvertures. Ne
pas utiliser le produit si l’une ou l’autre des ouver-
tures est obstruée. Enlever toute la poussière, toutes
les peluches et tous les cheveux, ou tout autre élé-
ment pouvant réduire la circulation de l’air.
C’est possible que les décharges statiques se
passent dans des endroits humides ou bien,
quand l’humidité relative de l’air est basse. Ceci
est temporel et n’affectera pas la performance de
l’aspirateur. An de minimiser la fréquence des
décharges statiques, ajouter de l’humidité à l’air à
l’aide d’une console ou un humidicateur installé.
Certains types de bois contiennent des con-
servateurs et pourront donc être toxiques.
Redoubler la prudence an d’éviter leur inhala-
tion et leur contact avec votre peau lorsque des
travaux sont faits avec ces matériaux. Demander
au fabricant du matériel toutes les informations de
sécurité disponibles et veuillez les suivre.
Entretien de l’aspirateur. Vérifier qu'aucune
pièce mobile n'est mal alignée ou bloquée,
qu'aucune pièce n'est brisée et s'assurer
qu'aucun autre problème ne risque d'affecter
le bon fonctionnement de l’aspirateur. En cas
de dommages, faire réparer l’aspirateur avant
10.Sangle inférieure du
sac à dos
11. Interrupteur
12. Tuyau exible
13. Rallonge télescopique
pour lance
14. Outil pour plancher
15. Adaptateur de
dépoussiérage
16. Suceur plat
17. Filtre HEPA
10
11
Retrait/Installation du ltre
Pour enlever le ltre :
Bouton de déverrouillage
du réservoir
Réservoir
Filtre
Couvercle
du réservoir
1. Retirer le bloc-piles.
2. Appuyer sur le bouton
d'activation du réservoir
et enlever le réservoir de
l’aspirateur.
3. Faire sortir le couvercle du
réservoir pour exposer le
tuyau. Retirer le filtre du
réservoir.
4. Relever le bouton de déver-
rouillage du réservoir et vider
toute la poussière et le débris
dans le réservoir.
5. Pour nettoyer le filtre,
veuillez le taper ou soufer
la poussière à l'aide de l’air
comprimé. Changer le ltre
s’il est endommagé ou si l’aspiration est réduite
(seul paquet ; Nº de cat.: 49-90-1963).
REMARQUE : Ne jamais utiliser d’eau pour net-
toyer le ltre.
Pour installer le ltre :
1. Mettre le filtre dans la partie supérieure du
réservoir.
2. Aligner les guides sur le couvercle du réservoir
et le xer sur place. Remettre le réservoir dans
l’aspirateur.
AVERTISSEMENT
Utiliser seulement des accessoires spécialement
recommandés pour cet outil. L’utilisation
d’autres types d’accessoires pourrait entraîner
des situations dangereuses.
Installation / Retrait des accessoires
Pour installer le tuyau, appuyer sur l’accessoire
pour le faire entrer dans l’entrée de l’aspirateur.
Pour installer les buses et les extensions, appuyer
sur l'accessoire pour le faire entrer dans le bout de
tuyau.
Pour l’enlever, appuyer sur le clip de l’accessoire
et le retirer.
Rangement des accessoires
C'est possible de ranger dans
Outil pour
plancher
Rallonge
télescopique
pour lance
l'aspirateur tous les acces-
soires.
Rallonge télescopique
pour lance : Utiliser un clip
pour attacher l’accessoire
sur le support prolongateur
de la lance.
Outil pour plancher :
Insérer l’accessoire dans
la partie supérieure de la
rallonge télescopique pour
lance.
Tuyau flexible : Insérer
Tuyau
flexible
l'accessoire dans l’entrée de
l'aspirateur. Utiliser le clip de
tuyau pour le xer.
Suceur plat : Attacher l'accessoire sur les
barreaux du suceur plat qui se trouvent sur la
sangle inférieure du sac à dos. Appuyer sur le nez
de l'accessoire pour le faire passer à travers du
barreau inférieur et attacher la partie supérieure
sur le barreau supérieur.
Adaptateur de dépoussiérage : Attacher
l'accessoire sur le barreau de l’adaptateur de
dépoussiérage trouvé dans la sangle inférieure
du sac à dos.
Suceur
plat
Adaptateur de
dépoussiérage
Enlèvement/installation de la plaque
de sac à dos
C'est possible d’enlever la plaque de sac à dos
lorsque l’aspirateur est monté sur une surface ou
bien, que vous le portez par la main.
Pour enlever la plaque, appuyer le bouton de
déverrouillage de la plaque de sac à dos et le te-
nir enfoncé. Tirer sur le bout inférieur de la plaque
et le faire sortir de l’aspirateur an d’enlever les
languettes inférieures. Baisser la plaque et l’enlever
de l’aspirateur pour enlever les languettes inféri-
eures.
Bouton de déverrouillage de la plaque de sac à dos
Pour installer la plaque, aligner et insérer
les languettes supérieures de la plaque dans
l’aspirateur. Relever la plaque pour aligner et in-
sérer les languettes inférieures de la plaque dans
l’aspirateur. Appuyer sur les languettes pour les
verrouiller.
Support de l’aspirateur
C'est possible d’accrocher l’aspirateur et le monter
sur une surface pour faciliter son utilisation.
Pour monter l’aspirateur, enlever la plaque de sac
à dos selon les consignes dans la section « En-
lèvement/installation de la plaque de sac à dos ».
Ceci exposera le support de xation. Tirer sur le
support pour le faire sortir de l’aspirateur, retirer les
supports dans les sangles du support et attacher
l’aspirateur sur une surface. Veuillez l'attacher en
xant les sangles du support et les serrant sur la
surface.
Support de
fixation
Sangles
du support
Pour démonter l'aspirateur, retirer les sangles du
support. Tirer sur le support qui se trouve dans la
surface et le remettre dans l’aspirateur. Remettre
la plaque de sac à dos selon les consignes dans la
section « Enlèvement/installation de la plaque de
sac à dos ».
MANIEMENT
AVERTISSEMENT
An de réduire le risque d'incendie et de bles-
sure, ne pas utiliser pour ramasser des matières
inammables.
Pour réduire le risque de blessure, porter des
lunettes de sécurité ou des lunettes avec écrans
latéraux. Vider le réservoir avant utilisation.
Avant de son utilisation, veuillez s’assurer que
le ltre soit installé.
AVERTISSEMENT
Ne pas amener l’aspirateur par la poignée du
réservoir.
Démarrage, arrête et contrôle de vitesse
Glisser le commutateur de démarrage vers le haut
pour le régler dans la position 2 an de démarrer
l’aspirateur à haute puissance. Glisser le commuta-
teur de démarrage vers le bas pour le régler dans
la position 1 an de démarrer l’aspirateur à puissance
faible. Pour arrêter l’aspirateur, remettre le commu-
tateur de démarrage dans sa position initiale.
SPÉCIFICATIONS
No de Cat. ................................................. 0885-20
Volts.............................................................. 18 CD
Type de batterie ...........................................M18™
Type de chargeur ........................................M18™
Volume d’air .............................55 pi
3
/min (55 CFM)
Aspiration jointive ............................193,0 cm (76")
Débit d'air ................................................ 159 watts
Capacité .............................................3,8 L (1 Gal.)
Température ambiante de fonctionnement
recommandée ........... -18°C
à
50°C (0°F
à
125°F)
Rallonge télescopique pour lance ........ 14-37-0005
Tuyau exible .......................................31-01-0305
Suceur plat ........................................... 31-01-0310
Outil pour plancher ............................... 31-01-0315
Adaptateur de dépoussiérage .............. 31-01-0320
Filtre HEPA ...........................................49-90-1963
Tuyau accessoire de 2,7 m (9’) ............49-90-1964
PICTOGRAPHIE
Volts
Courant direct
Lire le manuel d’utilisation
Toujours porter une protection oculaire
C
US
UL Listing Mark pour
Canada et États-unis
MONTAGE DE
L'OUTIL
AVERTISSEMENT
An de réduire les risques de blessures, toujours
retirer le bloc-piles avant de retirer le réservoir.
MISE EN GARDE
Garder le ltre propre. L’efcacité de l’aspirateur
dépend en grande partie du ltre. Un ltre sale
réduit la circulation de l’air ainsi que l’efcacité
globale du système. Ne pas utiliser de l’eau. Le
retirer du réservoir et le nettoyer en frappant ou
en soufant avec de l’air comprimé.
Insertion et retrait de la pile
Pour retirer la pile, appuyer sur les boutons de
relâchement et extraire le bloc-piles de l’outil.
AVERTISSEMENT
Retirer toujours le bloc-piles avant de changer ou
de retirer les accessoires.
Pour insérer la pile, la glisser dans le corps de l’outil.
S’assurer qu’il y est bien inséré en place.
12
13
AVERTISSEMENT
Pour minimiser les risques de blessures ou de
dommages à l'outil, n'immergez jamais l'outil, la
batterie ou le chargeur et ne laissez pas de liquide
s'y inltrer.
Nettoyage
Débarrassez les évents des débris et de la poussière.
Gardez les poignées propres, à sec et exemptes
d’huile ou de graisse. Le nettoyage doit se faire
avec un linge humide et un savon doux. Certains
nettoyants tels l’essence, la térébenthine, les dilu-
ants à laque ou à peinture, les solvants chlorés,
l’ammoniaque et les détergents d’usage domestique
qui en contiennent pourraient détériorer le plastique
et l’isolation des pièces. Ne laissez jamais de solvants
inammables ou combustibles auprès des outils.
Réparations
Pour les réparations, retournez outil, batterie et
chargeur en entier au centre-service le plus près.
ACCESOIRES
AVERTISSEMENT
L’utilisation d’autres accessoires que ceux qui
sont spécifiquement recommandés pour cet
outil peut comporter des risques.
Pour une liste complète des accessoires, visiter le
site internet www.milwaukeetool.com ou contactez
un distributeur.
SERVICE - CANADA
Milwaukee Tool (Canada) Ltd
1.800.268.4015
Monday-Friday, 7:00 AM - 4:30 PM CST
www.milwaukeetool.ca
GARANTIE LIMITÉE -
AUX ÉTATS-UNIS ET AU CANADA
Chaque outil électrique* MILWAUKEE (voir exceptions ci-dessous) est
garanti à l’acheteur d’origine uniquement pour être exempt de vices
de matériaux et de fabrication. Sous réserve de certaines exceptions,
MILWAUKEE réparera ou remplacera toute pièce d’un outil électrique
qui, après examen par MILWAUKEE, s’est avérée être affectée
d’un vice de matériau ou de fabrication et ce pendant une période
de cinq (5) ans** à compter de la date d’achat, sauf indication con-
traire. Retourner l’outil électrique à un centre de réparation en usine
MILWAUKEE ou à un poste d’entretien agréé MILWAUKEE, en port
prépayé et assuré. Une copie de la preuve d’achat doit être présentée
lors du retour du produit. Cette garantie ne couvre pas les dommages
que MILWAUKEE détermine être causés par des réparations ou des
tentatives de réparation par quiconque autre que le personnel agréé
par MILWAUKEE, ou par des utilisations incorrectes, des altérations,
des utilisations abusives, une usure normale, une carence d’entretien
ou des accidents.
Usure normale : Plusieurs outils électriques requièrent un remplace-
ment et un entretien périodique de leurs pièces pour un meilleur
rendement. Cette garantie ne couvre pas la réparation des pièces
due à l’utilisation normale de l’outil, y compris, mais sans s’y limiter,
les mandrins, les brosses, les cordes, les sabots de scie, les porte-
lames, les joints toriques, les joints, les amortisseurs, les lames
d’entraînement, les pistons, les percuteurs, les crochets et les rondelles
à couvercle amortisseur.
*Cette garantie ne s’applique pas aux cloueuses-agrafeuses pneu-
matiques, aux pulvérisateurs à peinture sans air, aux blocs-piles pour
outils sans l, aux génératrices d’alimentation portatives à essence,
aux outils à main, aux monte-charges – électriques, à levier et à
chaîne, aux vestes chauffantes M12™, aux produits ré-usinés, ni
aux produits d’essai et de mesure. Il existe des garanties séparées
distinctes pour ces produits.
**La période de garantie applicable pour les radios de chantier, le
port d’alimentation M12™, la source électrique M18™, le ventilateur
de chantier et les chariots de travail industriels Trade Titan™ est
d’une durée d’un (1) an à compter de la date d’achat. La période de
garantie pour les Câbles de nettoyage des canalisations est de deux
(2) ans à compter de la date d’achat. La période de garantie pour le
Pistolet thermique compact M18™ et Dépoussiéreur de 8 gallons est
de trois (3) ans à compter de la date d’achat. La période de garantie
couvrant la DEL de la lampe de travail à DEL et l’ampoule améliorée
à DEL de la lampe de travail est une garantie à vie du produit soumise
aux limitations ci-dessus. En cas de défaillance de la DEL ou de
l’ampoule à DEL pendant son utilisation normale, la pièce défaillante
sera remplacée gratuitement.
L’enregistrement de la garantie n’est pas nécessaire pour bénécier
de la garantie en vigueur sur un outil électrique MILWAUKEE. La
date de fabrication du produit servira à établir la période de garantie,
si aucune preuve d’achat n’est fournie lorsqu’une demande de service
sous garantie est déposée.
L’ACCEPTATION DES RECOURS EXCLUSIFS DE RÉPARATION
ET DE REMPLACEMENT DÉCRITS DANS LES PRÉSENTES EST
UNE CONDITION DU CONTRAT D’ACHAT DE TOUT PRODUIT
MILWAUKEE. SI VOUS N’ACCEPTEZ PAS CETTE CONDITION,
VOUS NE DEVEZ PAS ACHETER LE PRODUIT. EN AUCUN
CAS, MILWAUKEE NE SAURAIT ÊTRE RESPONSABLE DE
TOUT DOMMAGE ACCESSOIRE, SPÉCIAL OU INDIRECT, DE
DOMMAGES-INTÉRÊTS PUNITIFS OU DE TOUTE DÉPENSE,
D’HONORAIRES D’AVOCAT, DE FRAIS, DE PERTE OU DE DÉLAIS
ACCESSOIRES À TOUT DOMMAGE, DÉFAILLANCE OU DÉFAUT
DE TOUT PRODUIT, Y COMPRIS NOTAMMENT LES PERTES DE
PROFIT. CERTAINS ÉTATS ET PROVINCES NE PERMETTANT
L'EXCLUSION OU LA LIMITATION DES DOMMAGES DIRECTS OU
INDIRECTS, LES RESTRICTIONS CI-DESSUS PEUVENT NE PAS
VOUS ÊTRE APPLICABLES. CETTE GARANTIE EST EXCLUSIVE
ET REMPLACE TOUTE AUTRE GARANTIE EXPRESSE, QU’ELLE
SOIT VERBALE OU ÉCRITE. DANS LA MESURE PERMISE PAR
LA LOI, MILWAUKEE RENONCE À TOUTE GARANTIE IMPLICITE, Y
COMPRIS, MAIS SANS S’Y LIMITER, TOUTE GARANTIE IMPLICITE
DE QUALITÉ MARCHANDE OU D’ADAPTATION À UNE UTILISA-
TION OU À UNE FIN PARTICULIÈRE. DANS LA MESURE OÙ UNE
TELLE STIPULATION D’EXONÉRATION N’EST PAS PERMISE PAR
LA LOI, LA DURÉE DE CES GARANTIES IMPLICITES EST LIMITÉE
À LA PÉRIODE APPLICABLE DE LA GARANTIE EXPRESSE, TEL
QUE CELA EST DÉCRIT PRÉCÉDEMMENT. CERTAINS ÉTATS ET
PROVINCES NE PERMETTANT PAS DE LIMITATION DE DURÉE
DES GARANTIES IMPLICITES, LES RESTRICTIONS CI¬DESSUS
PEUVENT DONC NE PAS VOUS ÊTRE APPLICABLES. LA PRÉSEN-
TE VOUS CONFÈRE DES DROITS LÉGAUX PARTICULIERS; VOUS
BÉNÉFICIEZ ÉGALEMENT D’AUTRES DROITS QUI VARIENT D’UN
ÉTAT À UN AUTRE.
Cette garantie s’applique aux produits vendus aux États-Unis et au
Canada uniquement.
Veuillez consulter la rubrique Centre SAV Milwaukee, dans la sec-
tion Pièces et Services du site Web de MILWAUKEE, à l’adresse
www.milwaukeetool.com, ou composer le 1-800-SAWDUST (1-
800-729-3878) an de trouver le centre de service de votre région
le plus proche pour l’entretien, sous garantie ou non, de votre outil
électrique Milwaukee.
GARANTIE LIMITÉE – MEXIQUE,
AMÉRIQUE CENTRALE ET CARAÏBES
TECHTRONIC INDUSTRIES' garantit le produit pendant 5 ans à partir
de la date d’achat d’origine.
Le présent bon de garantie couvre tous les vices de matériau et de
fabrication que peut afcher ce produit.
Pour assurer la validité de la présente garantie, veuillez présenter ce
bon de garantie, estampillé du sceau du distributeur ou du magasin
où le produit a été acheté, au centre de réparations agréé. Si le bon
de garantie n’a pas été estampillé, veuillez fournir la preuve d’achat
d’origine au centre de réparations agréé.
Pour un entretien des pièces, des accessoires ou des composants,
composer sans frais le 1-800-030-7777 an d’obtenir les coordonnées
du centre de réparations agréé le plus près
Procédure pour assurer la validité de la garantie
Présenter le produit au centre de réparations agréé, accompagné du
bon de garantie estampillé du sceau du distributeur ou du magasin où
le produit a été acheté. Toute pièce défectueuse ou tout composant
défectueux sera remplacé(e) sans frais. Milwaukee assume tous les
frais de transport liés à ce processus de garantie.
Exceptions
Cette garantie ne s’applique pas dans les situations suivantes :
a) Si le produit a été utilisé pour une n autre que celle indiquée dans
le guide de l’utilisateur nal ou le manuel d’instructions.
b) Si les conditions d’utilisations ne sont pas habituelles.
c) Si le produit a été modié ou réparé par une personne non autorisée
par TECHTRONIC INDUSTRIES.
Remarque : Si le cordon électrique est endommagé, il doit être
remplacé par un centre de réparations agréé pour éviter les risques
d’électrocution.
CENTRE DE RÉPARATIONS ET DE SERVICE
Composer le 01 (800) 030-7777
IMPORTÉ ET COMMERCIALISÉ PAR
TECHTRONIC INDUSTRIES, MEXIQUE, SA DE CV
Av President Masarik #29 piso 7, Col. Polanco V Sección
CP 11560, Deleg. Miguel Hidalgo, CDMX
Modèle :
Date d’achat :
Sceau du distributeur ou du magasin :
REGLAS DE
SEGURIDAD
GENERALES
ADVERTENCIA
PARA DIS-
MINUIR EL
RIESGO DE INCENDIO O LESIÓN AL
USAR UNA ASPIRADORA ELÉCTRICA,
SIEMPRE DEBE SEGUIR LAS PRECAU-
CIONES BÁSICAS, INCLUIDAS LAS
SIGUIENTES: LEA TODAS LAS IN-
STRUCCIONES ANTES DE USAR LA
ASPIRADORA. PARA USO DOMÉSTICO
O COMERCIAL. ANTES DE UTILIZAR
LA ASPIRADORA, LEA ESTE MANUAL
DEL OPERADOR, LOS MANUALES DE
LA BATERÍA Y EL CARGADOR Y TODAS
LAS ETIQUETAS DE LA ASPIRADORA,
LA BATERÍA Y EL CARGADOR.
SEGURIDAD EN EL ÁREA
DE TRABAJO
Mantenga el área de trabajo limpia y bien ilu-
minada. Las áreas desordenadas u oscuras son
propicias para los accidentes.
No se utilice en presencia de polvo, líquidos o
vapores explosivos.
No se utilice donde se use oxígeno o anestésicos.
No permita que se use como un juguete. Es
necesario prestar mucha atención cuando lo usen
niños o cuando se use cerca de ellos.
Sea particularmente cuidadoso al usarlo en
escaleras.
SEGURIDAD ELÉCTRICA
No recoja material húmedo. No use agua para
que no se levante el polvo.
No maneje la batería ni la aspiradora con las
manos húmedas.
Almacénese en interiores. No se exponga a la
lluvia.
SEGURIDAD PERSONAL
• MANTÉNGASE ALERTA. Preste atención a lo que
está haciendo y use el sentido común. No use la
aspiradora mientras está cansado, distraído o bajo
la inuencia de drogas, alcohol o medicamentos
que ocasionen disminución del control.
Utilisation de l’aspirateur
L’aspirateur peut être utilisé des nombreuses façons
qui conviennent le mieux au travail que vous ferez.
Porter l’aspirateur comme un sac à dos. Mettre
l’aspirateur sur votre corps. Attacher l’outil en
utilisant les sangles supérieures et inférieures du
sac à dos.
Montage de l’aspirateur sur une surface. Enlever
la plaque de sac à dos selon les consignes dans la
section « Enlèvement/installation de la plaque de
sac à dos ». Après, monter l’aspirateur sur la surface
selon les consignes dans la section « Montage de
l’aspirateur ».
Emporter l’aspirateur à main. Enlever, au besoin,
la plaque de sac à dos selon les consignes dans
la section « Enlèvement/installation de la plaque
de sac à dos ».
Fonctionnement
1. Retirer TOUTE la poussière et TOUT le débris qui
se trouvent dans le réservoir.
2. Insérer le bloc-piles et attacher les accessoires.
3. Régler le commutateur de démarrage dans la
vitesse souhaitée. Le relever.
4. Arrêter l’aspirateur immédiatement après
l'achèvement de votre travail ou bien, quand
le réservoir soit plein et prêt pour le vider.
REMARQUE : Si l’aspiration est interrompue,
arrêter l’aspirateur immédiatement et vider le
réservoir.
5. Retirer le bloc-piles.
6. Nettoyer l’intérieur du réservoir et les accessoires
périodiquement.
Entreposage
Avant d’entreposer l’aspirateur, vider et nettoyer le
réservoir, le ltre et les accessoires. Retirer la pile.
ENTRETIEN
AVERTISSEMENT
Pour minimiser les risques de blessures corpo-
relles, débranchez le chargeur et retirez la bat-
terie du chargeur ou de l’outil avant d’y effectuer
des travaux d’entretien. Ne démontez jamais
l’outil, la batterie ou le chargeur. Pour toute
réparation, consultez un centre de service MIL-
WAUKEE accrédité.
Entretien de l’outil
Gardez l’outil en bon état en adoptant un programme
d’entretien ponctuel. Inspectez votre outil pour des
questions telles que le bruit excessif, de grippage
des pièces mobiles, de pièces cassées ou toute
autre condition qui peut affecter le fonctionnement
de l'outil. Retournez votre outil à un centre de service
MILWAUKEE accrédité pour obtenir le service. Après
une période pouvant aller de 6 mois à un an, selon
l’usage, retournez votre outil à un centre de service
MILWAUKEE accrédité pour d'inspection.
Si l’outil ne démarre pas ou ne fonctionne pas à
pleine puissance alors qu’il est branché sur une
batterie complètement chargée, nettoyez les points
de contact entre la batterie et l’outil. Si l’outil ne
fonctionne toujours pas correctement, renvoyez
l’outil, le chargeur et la batterie à un centre de service
MILWAUKEE accrédité.
14
15
mantenimiento a la aspiradora. Verique
que no haya desalineación, amarre de partes
móviles, partes rotas o alguna otra condición
que pueda afectar el funcionamiento de la as-
piradora. Si se daña, asegúrese de que la aspi-
radora sea reparada antes de utilizarse. Muchos
accidentes son ocasionados por herramientas con
mantenimiento deciente.
Válgase siempre de su sentido común y sea
cuidadoso cuando utilice herramientas. No es
posible anticipar todas las situaciones que podrían
tener un desenlace peligroso. No utilice esta her-
ramienta si no entiende estas instrucciones de uso
o si considera que el trabajo a realizar supera sus
capacidades, comuníquese con Milwaukee Tool o con
un profesional capacitado para recibir capacitación
o información adicional.
• Conserv
e las etiquetas y las placas nominales.
Contienen información importante. Si son ilegibles o no
están presentes, comuníquese con un centro de servi-
cio MILWAUKEE para obtener un reemplazo gratuito.
Este producto es adecuado para la recolección
de polvo de sílice cuando se utiliza de acuerdo
con estas instrucciones. Para reducir el riesgo
de peligros en la salud por inhalación de otros
vapores o polvo, no aspire materiales tóxicos,
cancerígenos ni otras sustancias peligrosas,
como por ejemplo asbestos, arsénico, bario, berilio,
plomo, pesticidas u otras sustancias que pongan en
riesgo su salud.
ADVERTENCIA
Algunos polvos
generados por
el lijado eléctrico, aserrado, pulido, taladrado y otras
actividades de construcción contienen químicos
identicados como causantes de cáncer, defectos
congénitos u otros daños reproductivos. Algunos
ejemplos de estos químicos son:
plomo de pintura basada en plomo
dióxido de silicio de los ladrillos y el cemento y otros
productos de albañilería y
arsénico y cromo de madera con tratamiento
químico.
Su riesgo por estas exposiciones varía, dependi-
endo de la frecuencia con que realice este tipo de
trabajo. Para reducir su exposición a estos quími-
cos: trabaje en un área bien ventilada y trabaje con
equipo de seguridad aprobado, como mascarillas
protectoras contra polvo especialmente diseñadas
para ltrar partículas microscópicas.
La unidad cumple como una solución de datos
objetivos de la norma OSHA 29CRF 1926.1153
cuando se usa sin el recolector de polvo,
suponiendo que se usa de conformidad con las
instrucciones de MILWAUKEE. Para más de-
talles sobre los métodos de cumplimiento, haga
referencia a https://www.osha.gov. Visite
https://www.milwaukeetool.com para obtener una
cha técnica objetiva.
USO Y CUIDADO DE LAS
HERRAMIENTAS CON BATERÍA
Utilice la aspiradora únicamente con baterías
especícamente diseñadas. El uso de cualquier
otra batería puede producir un riesgo de lesiones
e incendio.
Apague todos los controles antes de retirar la
batería.
Para reducir el riesgo de descarga eléctrica, no
lo utilice en supercies húmedas. No se exponga
a la lluvia. Almacene en interiores.
Antes de usar la batería o el cargador, lea los
manuales del operador y todas las etiquetas de
la batería, el cargador y la aspiradora.
Recargue únicamente con el cargador espe-
cicado por el fabricante. Un cargador que es
adecuado para un tipo de batería puede crear un
riesgo de incendio si se utiliza con otra batería.
Cuando la batería no está en uso, manténgala
alejada de otros objetos metálicos como su-
jetapapeles, monedas, llaves, clavos, tornillos
u otros objetos metálicos pequeños que puedan
formar una conexión de una terminal a otra.
Crear un corto entre las terminales puede ocasionar
quemaduras o un incendio.
No utilice una batería o aspiradora dañada. Si la
batería o la aspiradora no está funcionando como
debería, se ha dejado caer, está dañada, se dejó a
la intemperie o cayó en agua, regrésela a un centro
de servicio.
MANTENIMIENTO
Lleve su herramienta eléctrica a servicio con un
técnico calicado que use únicamente piezas
de reemplazo idénticas. Esto asegurará que la
seguridad de la herramienta eléctrica se mantenga.
Nunca servicio a baterías dañadas. Únicamente
el fabricante o proveedores de servicio autorizados
deben dar servicio a las baterías.
REGLAS ESPECIFICAS
DE SEGURIDAD
Antes de utilizar la aspiradora, lea este manual
del operador, los manuales de la batería y el
cargador y todas las etiquetas de la aspiradora,
la batería y el cargador.
Nunca use la aspiradora si el tanque y/o los
ltros no están instalados correctamente. La
aspiradora aventará polvo y basura al aire.
Nunca limpie el ltro con agua. Limpie con
pequeños golpecitos o limpie el polvo con aire
comprimido. El agua provocará que falle el ltro.
Utilice protectores auditivos. La exposición al
ruido puede causar pérdida auditiva.
LEA Y CONSERVE
TODAS LAS
INSTRUCCIONES
PARA
CONSULTARLAS EN
EL FUTURO
DESCRIPCION
FUNCIONAL
1
2
6
8
11
7
4
10
3
9
12
13
14
16
15
17
5
1. Asa para traslado
2. Botón del asa del tanque
3. Tanque
4. Base de la batería
5. Broche de la manguera
6. Válvula de entrada de la
aspiradora
7. Soporte del tubo de
extensión
8. Correas superiores
de la mochila
9. Placa de la mochila
La operación de una aspiradora puede ocasionar
que objetos extraños sean lanzados hacia los
ojos, lo que puede causar daño ocular. Siempre
use lentes o gafas de seguridad con protectores
laterales al usar la aspiradora.
Utilice una mascarilla facial o use una solución
de extracción de polvo que cumpla con las
normas de OSHA cuando trabaje en condiciones
de mucho polvo. Las partículas de polvo pueden
dañar sus pulmones.
Evite el arranque accidental. Asegúrese de
que el interruptor esté en posición de apagado
antes de insertar la batería. Insertar la batería en
una aspiradora con el interruptor en posición de
encendido es invitar a que ocurra un accidente.
No estire el cuerpo demasiado. Mantenga un
buen contacto entre los pies y el suelo y man-
tenga el equilibrio en todo momento. Esto permite
un mejor control de la aspiradora en situaciones
inesperadas.
Nunca se pare en la aspiradora ni la use como
escalón.
Mantenga el cabello, ropa holgada, dedos y to-
das las partes del cuerpo lejos de las aberturas
y partes móviles.
Utilice únicamente como se describe en este
manual. Utilice únicamente los accesorios reco-
mendados por el fabricante.
USO Y CUIDADO
Sólo utilice el producto de la forma descrita en
este manual. Use solamente accesorios recomen-
dados por el fabricante.
No se utilice para levantar líquidos inamables o
combustibles como gasolina, ni se utilice en áreas
donde puedan estar presentes.
No levante nada que se esté quemando o emi-
tiendo humo, como cigarrillos, cerillos o cenizas
calientes.
No levante hollín, cemento, yeso o polvo de
tablarroca si el ltro no está colocado. Estas
son partículas muy nas que pueden afectar el
desempeño del motor o regresarse al ambiente.
Para reducir el riesgo, no la utilice para aspirar
materiales peligrosos, tóxicos o carcinógenos,
como asbesto o pesticidas.
Tenga especial cuidado al descargar tanques
muy cargados.
Para evitar la combustión espontánea, vacíe el
recolector de polvo después de cada uso.
No deje la aspiradora sin supervisión cuando
tenga instalada la batería. Retire la batería cuando
no lo use y antes de realizarle un servicio.
No coloque ningún objeto en las aberturas.
No use con ninguna de las aberturas bloqueadas;
manténgalas libres de polvo, pelusa, cabello o cual-
quier otro objeto que pudiera reducir el ujo de aire.
Es posible que haya choques por estática en
áreas secas o cuando la humedad relativa del
aire es baja. Esta es una situación temporal y no
afecta el uso de la aspiradora. Para disminuir la fre-
cuencia de choques por estática, agregue humedad
al aire con un humidicador de consola o instalado.
Algunas maderas contienen conservadores y
pueden ser tóxicos. Tenga mucho cuidado para
evitar la inhalación y el contacto con la piel
cuando trabaje con estos materiales. Solicite y
siga cualquier información de seguridad disponible
con su proveedor de material.
10. Correas inferiores de
la mochila
11. Interruptor
12. Manguera exible
13. Tubo de extensión
telescópico
14. Herramienta para el piso
15. Adaptador de
extracción de polvo
16. Herramienta para
resquicios
17. Filtro HEPA
16
17
SIMBOLOGÍA
Volts
Corriente continua
Lea el manual del operador
Siempre use protección para los ojos.
C
US
UL Listing Mark para
Canadá y Estados Unidos
ESPECIFICACIONES
Cat. No. ..................................................... 0885-20
Volts.............................................................. 18 CD
Tipo de batería .............................................M18™
Tipo de cargador ..........................................M18™
Volumen de aire.......................55 pi
3
/min (55 CFM)
Succión sellada ...............................193,0 cm (76")
Potencia de aire...................................... 159 vatios
Capacidades.......................................3,8 L (1 Gal.)
Temperatura ambiente recomendada
para operar .............. -18°C
to
50°C (0°F to 125°F)
Tubo de extensión telescópico ............. 14-37-0005
Manguera exible ................................. 31-01-0305
Herramienta para resquicios ................ 31-01-0310
Herramienta para el piso ...................... 31-01-0315
Adaptador de extracción de polvo ........ 31-01-0320
Filtro HEPA ...........................................49-90-1963
Manguera complementaria
de 2,7 m (9') ......................................... 49-90-1964
ENSAMBLAJE
ADVERTENCIA
Para reducir el
riesgo de
lesión, siempre retire las baterías antes de retirar
el tanque.
PRECAUCIÓN
Mantenga el ltro
limpio. La efica-
cia de la aspira-
dora depende mucho del ltro. Un ltro sucio
reducirá el ujo de aire y la ecacia general del
sistema. No limpie con agua. Retire del tanque y
dé golpecitos o use aire comprimido para limpi-
arlo.
Retirar/insertar la batería
Para extraer la batería, presione los botones de liber-
ación y jale la batería para sacarla de la herramienta.
ADVERTENCIA
Siempre retire
la batería antes
de cambiar o retirar los accesorios.
Para insertar la batería, deslícela dentro del cuerpo
de la herramienta. Asegúrese de que se je rme-
mente en su lugar.
Retirar/instalar el ltro
Para retirar el ltro:
Botón de liberación
del tanque
Tanque
Filtro
Tapa del
tanque
1. Extraiga la batería.
2. Oprima el botón del asa del
tanque y retire el tanque de la
aspiradora.
3. Jale la tapa del tanque para
exponer el ltro. Retire el ltro
del tanque.
4. Levante el botón de liberación
del tanque y vacíe todo el polvo
y basura del tanque.
5. Para limpiar el ltro, dé peque-
ños golpecitos o limpie el polvo
con aire comprimido. Reem-
place el ltro si está dañado o
disminuye la succión (paquete
único, Cat. No. 49-90-1963).
NOTA: Nunca limpie el ltro con agua.
Para instalar el ltro:
1. Coloque el ltro en la parte superior del tanque.
2. Alinee las guías de la tapa del tanque y fíjela al
tanque. Vuelva a colocar el tanque en la aspira-
dora.
ADVERTENCIA
Utilice única-
mente acceso-
rios especícamente recomendados para esta
herramienta. Puede ser peligroso utilizar otros.
Instalación/remoción de los accesorios
Para instalar la manguera, empuje el accesorio en
la entrada de la aspiradora. Para instalar las bo-
quillas y extensiones, empuje el accesorio en el
extremo de la manguera.
Para retirar, oprima el broche del accesorio y jale.
Guardar los accesorios
Cada accesorio puede guard-
Herramienta
para el piso
Tubo de
extensión
telescópico
arse in la aspiradora.
Tubo de extensión
telescópico: Abroche el
accesorio en el soporte del
tubo de extensión.
Herramienta para el piso:
Inserte el accesorio en la
parte superior del tubo de
extensión telescópico.
Manguera exible: Inserte el
Manguera
flexible
accesorio en la entrada de
la aspiradora. Abroche en el
broche de la manguera para
jarla.
Herramienta para resquicios: Enganche el
accesorio en los travesaños de la herramienta
para resquicios ubicado en la correa inferior de
la mochila. Empuje la punta del accesorio por el
travesaño inferior y amarre con la correa a la parte
superior al travesaño superior.
Adaptador de extracción de polvo: Enganche
el accesorio en el travesaño del adaptador de
extracción de polvo ubicado en la correa inferior
de la mochila.
Herramienta
para
resquicios
Adaptador de
extracción de
polvo
Retirar o instalar la placa de la mochila
La placa de la mochila puede retirarse cuando se
monta la aspiradora en una supercie o se carga
a mano.
Para retirar la placa, oprima y sostenga el botón de
liberación de la placa de la mochila. Jale el extremo
inferior de la placa alejado de la aspiradora para
retirar las pestañas inferiores. Jale la placa hacia
abajo y alejada de la aspiradora para retirar las
pestañas superiores.
Botón de liberación de la placa de la mochila
Para instalar la placa, alinee e inserte las pestañas
superiores de la placa en la aspiradora. Levante la
placa para alinear e insertar las pestañas inferiores
de la placa dentro de la aspiradora. Empuje las
pestañas hacia adentro para bloquear.
Montar la aspiradora
La aspiradora puede colgarse y montarse a una su-
percie para facilidad de uso.
Para montar la aspiradora, retire la placa de la mo-
chila de conformidad con las instrucciones de cómo
"Retirar o instalar la placa de la mochila”. Esto ex-
pondrá el gancho para montar. Jale el gancho ale-
jado de la aspiradora, desabroche las correas del
gancho y enganche la aspiradora en la supercie.
Fije abrochando las correas del gancho y apretan-
do en la supercie.
Gancho
para montar
Correas
del gancho
Para desmontar la aspiradora, desenganche las
correas del gancho. Jale el gancho de la supercie
y empuje el gancho hacia atrás en la aspiradora.
Vuelva a instalar la placa de la mochila de confor-
midad con las instrucciones de cómo "Retirar o in-
stalar la placa de la mochila”.
OPERACION
ADVERTENCIA
Para reducir el
riesgo de in-
cendio y lesiones, no use la herramienta para
aspirar materiales inamables ni combustibles.
Para reducir el riesgo de lesiones, utilice gafas
o lentes de seguridad con protectores laterales.
Vacíe el tanque antes de usarlo.
Antes de usar, asegúrese de que el ltro esté
instalado.
ADVERTENCIA
No cargue la
aspiradora por
el asa del tanque.
Cómo arrancar, detener y controlar
la velocidad
Oprima el interruptor de Encendido en el 2 para
operar la aspiradora en potencia Alta. Oprima el
interruptor de Encendido en el 1 para operar la
aspiradora en potencia Baja. Para apagar la aspi-
radora, regrese el interruptor de encendido a su
posición inicial.
18
19
Usar la aspiradora
Hay muchas maneras de usar la aspiradora que
mejor se adaptará a su trabajo.
Usar la aspiradora como mochila. Coloque
la aspiradora en su cuerpo. Fije la herramienta
amarrándola en la parte superior en inferior con
las correas de la mochila.
Montar la aspiradora en la supercie. Retire
la placa de la mochila de conformidad con las
instrucciones de cómo "Retirar o instalar la placa
de la mochila”. Después, monte la aspiradora a la
supercie de conformidad con las instrucciones de
“Montar la aspiradora”.
Cargar la aspiradora con la mano. Si lo desea,
retire la placa de la mochila de conformidad con las
instrucciones de cómo "Retirar o instalar la placa
de la mochila”.
Operación
1. Retire TODA la mugre y basura que encuentre en
el tanque.
2. Inserte la batería y je los accesorios.
3. Oprima el interruptor de Encendido a la velo-
cidad deseada. Inicie el aspirado.
4. Apague la aspiradora inmediatamente después
de terminar un trabajo o cuando el tanque esté
lleno y listo para vaciarse.
NOTA: Si se apaga la succión, apague la aspira-
dora inmediatamente y vacíe el tanque.
5. Quite la batería.
6. Limpie frecuentemente el interior del tanque y los
accesorios.
Almacepnamiento
Antes de guardar la aspiradora, vacíe y limpie el
tanque, el ltro y los accesorios. Retire la batería.
MANTENIMIENTO
ADVERTENCIA
Para reducir el
riesgo de una
lesión, desconecte siempre la herramienta antes
de darle cualquier mantenimiento. Nunca de-
sarme la herramienta ni trate de hacer modica-
ciones en el sistema eléctrico de la misma.
Acuda siempre a un Centro de Servicio
MILWAUKEE para TODAS las reparaciones.
Mantenimiento de las herramientas
Adopte un programa regular de mantenimiento y
mantenga su herramienta en buenas condiciones.
Inspeccione la herramienta para problemas como
ruidos indebidos, desalineadas o agarrotadas
de partes móviles, piezas rotas o cualquier otra
condición que pueda afectar el funcionamiento de
la herramienta. Envíe su herramienta al Centro de
Servicio MILWAUKEE para reparación. Después
de 6 meses a un año, dependiendo del uso
dado, envíe su herramienta al Centro de Servicio
MILWAUKEE más cercano para la inspección.
Si la herramienta no arranca u opera a toda su
potencia con una batería completamente cargada,
limpie, con una goma o borrador, los contactos de la
batería y de la herramienta. Si aun asi la herramienta
no trabaja correctamente, regrésela, con el cargador
y la batería, a un centro de servicio MILWAUKEE.
ADVERTENCIA
Para reducir el
riesgo de lesio-
nes, descarga eléctrica o daño a la herramienta,
nunca la sumerja en líquidos ni permita que estos
uyan dentro de la misma.
Limpieza
Limpie el polvo y suciedad de las ventilas. Man-
tenga los mangos limpios, secos y libres de aceite
o grasa. Use solo jabón neutro y un trapo húmedo
para limpiar, ya que algunos substancias y solventes
limpiadores son dañinos a los plásticos y partes
aislantes. Algunos de estos incluyen: gasolina,
turpentina,thíner, lacas, thíner para pinturas, solven-
tes para limpieza con cloro, amoníaco y detergentes
caseros que tengan amonia. Nunca usa solventes in-
amables o combustibles cerca de una herramienta.
Reparaciones
Si su herramienta, batería o cargador están dañados,
envíela al centro de servicio más cercano.
ACCESORIOS
ADVERTENCIA
Utilice sólo los
accesorios es-
pecícamente recomendados. Otros accesorios
puede ser peligroso.
Para una lista completa de accessorios, visite
nuestro sitio en Internet: www.milwaukeetool.com o
póngase en contacto con un distribuidor.
SOPORTE DE SERVICIO - MEXICO
CENTRO DE ATENCION A CLIENTES
Techtronic Industries Mexico, S.A. de C.V.
Av. Presidente Masarik 29 Piso 7
11560 Polanco V Seccion
Miguel Hidalgo, Distrito Federal, México
01 (800) 030-7777 o (55) 4160-3540
Lunes a Viernes (9am a 6pm)
O contáctanos en www.milwaukeetool.com.mx
GARANTÍA LIMITADA - E.U.A. Y CANADÁ
Cada herramienta eléctrica* de MILWAUKEE (ver excepciones a con-
tinuación) está garantizada para el comprador original únicamente de
que no tenga material y mano de obra defectuosos. Sujeto a ciertas
excepciones, MILWAUKEE reparará o reemplazará cualquier parte en
una herramienta eléctrica que tenga defectos de material o mano de
obra según lo determine MILWAUKEE mediante una revisión, por un
periodo de cinco (5) años** después de la fecha de compra a menos
que se indique lo contrario. Al devolver la herramienta eléctrica a un
Centro de Servicio de la fábrica de MILWAUKEE o a una Estación
de Servicio Autorizada de MILWAUKEE, se requiere que el ete esté
pagado por adelantado y asegurado. Se debe incluir una copia del
comprobante de compra con el producto devuelto. Esta garantía no
aplica a daños que MILWAUKEE determine que son ocasionados por
reparaciones o intentos de reparaciones realizados por una persona
que no sea personal autorizado de MILWAUKEE, uso indebido,
alteraciones, maltrato, desgaste normal, falta de mantenimiento o
accidentes.
Desgaste normal: Muchas herramientas eléctricas necesitan un
reemplazo periódico de partes y servicio para lograr el mejor des-
empeño. Esta garantía no cubre la reparación cuando el uso normal
ha agotado la vida de una parte, incluyendo sin limitar a mandriles,
cepillos, cables, zapatas de la sierra, abrazaderas de la hoja, anillos en
O, sellos, protectores, hojas de desatornilladores, pistones, herrajes,
levantadores y arandelas de cubierta de los protectores.
*Esta garantía no cubre clavadoras y grapadoras neumáticas, pistola
de pintura a presión, baterías inalámbricas, generadores de energía
portátil de gasolina, herramientas de mano, palanca y cadena de mano
de polipasto - eléctricas, indumentaria calefactada M12™, producto
reacondicionado y productos de prueba y medición. Existen garantías
por separado y distintas disponibles para estos productos.
**El periodo de garantía para los radios para obra, puerto de energía
M12™, fuente de poder M18™, ventiladores para obra y carretillas de
trabajo industrial Trade Titan™ es de un (1) año a partir de la fecha
de compra. El periodo de garantía para los Cables de limpieza de
drenaje es de dos (2) años a partir de la fecha de compra. El periodo
de garantía de la Pistola de calor compacta M18™ de la Extractor de
polvo de 8 galones es de tres (3) años a partir de la fecha de com-
pra. El periodo de garantía de las lámparas de LED en la Lámpara
de trabajo LED y el Bulbo mejorado de LED para la Luz de trabajo
es por la vida del producto sujeto a las limitaciones anteriores. Si
durante el uso normal el LED o Bulbo de LED falla, la parte será
reemplazada sin cargo.
No se requiere el registro de la garantía para obtener la garantía cor-
respondiente a un producto de herramienta eléctrica de MILWAUKEE.
La fecha de manufactura del producto se utilizará para determinar el
periodo de garantía si no se proporciona comprobante de compra al
solicitar el servicio en garantía.
LA ACEPTACIÓN DE LOS REMEDIOS EXCLUSIVOS DE REPA-
RACIÓN Y REEMPLAZO AQUÍ DESCRITOS ES UNA CONDICIÓN
DEL CONTRATO PARA LA COMPRA DE TODO PRODUCTO DE
MILWAUKEE. SI USTED NO ACEPTA ESTA CONDICIÓN, NO
DEBE COMPRAR EL PRODUCTO. MILWAUKEE NO SERÁ RE-
SPONSABLE EN NINGÚN CASO DE DAÑOS INCIDENTALES, ES-
PECIALES, EMERGENTES O PUNITIVOS NI DE NINGÚN COSTO,
HONORARIOS LEGALES, GASTOS, PÉRDIDAS O DEMORAS ALE-
GADOS COMO CONSECUENCIA DE ALGÚN DAÑO, FALLA O DE-
FECTO EN NINGÚN PRODUCTO, INCLUYENDO, ENTRE OTROS,
RECLAMACIONES POR PÉRDIDA DE UTILIDADES. ALGUNOS
ESTADOS NO PERMITEN LA EXCLUSIÓN O LIMITACIÓN DE RE-
SPONSABILIDAD POR DAÑOS INCIDENTALES O EMERGENTES,
POR LO QUE LA ANTERIOR LIMITACIÓN O EXCLUSIÓN PODRÍA
NO APLICARSE EN SU CASO. ESTA GARANTÍA ES EXCLUSIVA
Y REEMPLAZA TODAS LAS DEMÁS GARANTÍAS EXPRESAS, ES-
CRITAS U ORALES. EN LA MEDIDA EN QUE LO PERMITA LA LEY,
MILWAUKEE DESCONOCE CUALQUIER GARANTÍA IMPLÍCITA,
INCLUYENDO SIN LIMITACIÓN CUALQUIER GARANTÍA IMPLÍCITA
DE COMERCIABILIDAD O IDONEIDAD PARA UN FIN O USO ESPE-
CÍFICO; EN LA MEDIDA EN QUE DICHO DESCONOCIMIENTO NO
SEA PERMITIDO POR LA LEY, DICHAS GARANTÍAS IMPLÍCITAS
SE LIMITAN A LA DURACIÓN DE LA GARANTÍA EXPRESA COR-
RESPONDIENTE SEGÚN SE DESCRIBIÓ ANTERIORMENTE.
ALGUNOS ESTADOS NO PERMITEN LIMITACIONES SOBRE
LA DURACIÓN DE UNA GARANTÍA IMPLÍCITA, POR LO QUE LA
ANTERIOR LIMITACIÓN PUDIERA NO APLICARSE A USTED. ESTA
GARANTÍA LE DA DERECHOS LEGALES ESPECÍFICOS Y USTED
PODRÍA ADEMÁS TENER OTROS DERECHOS QUE VARÍAN DE
UN ESTADO A OTRO.
Esta garantía aplica al producto vendido en los Estados Unidos y
Canadá únicamente.
Consulte la “Búsqueda de centro de servicio” en la sección de Partes
y servicio del sitio web de MILWAUKEE en www.milwaukeetool.com o
llame al 1.800.SAWDUST (1.800.729.3878) para localizar su centro
de servicio más cercano para darle servicio con y sin garantía a una
herramienta eléctrica de Milwaukee.
PÓLIZA DE GARANTÍA - VALIDA
SOLO PARA MÉXICO, AMÉRICA
CENTRAL Y EL CARIBE
La garantía de TECHTRONIC INDUSTRIES es por 5 años a partir de
la fecha original de compra.
Esta tarjeta de garantía cubre cualquier defecto de material y mano
de obra en ese Producto.
Para hacer válida esta garantía, presente esta tarjeta de garantía,
cerrada/sellada por el distribuidor o la tienda donde compró el pro-
ducto, al Centro de Servicio Autorizado (ASC). O, si esta tarjeta no
se ha cerrado/sellado, presente la prueba original de compra a ASC.
Llame gratis al 01 (800) 030-7777 para encontrar el ASC más cercano,
para servicio, partes, accesorios o componentes.
Procedimiento para hacer válida esta garantía
Lleve el producto a ASC, junto con la tarjeta de garantía cerrada/
sellada por el distribuidor o la tienda donde compró el producto, y
cualquier pieza o componente defectuoso se reemplazará sin costo
para usted. Cubriremos todos los costos de ete con relación a este
proceso de garantía
Excepciones
Esta garantía no tendrá validez en las siguientes situaciones:
a) Cuando el producto se use de manera distinta a la que indica el
manual del usuario nal o de instrucciones.
b) Cuando las condiciones de uso no sean normales.
c)
Cuando otras personas no autorizadas por TECHTRONIC INDUSTRIES
modiquen o reparen el producto.
Nota: si el juego de cables está dañado, tiene que reemplazarse
en un Centro de Servicio Autorizado para evitar riesgos eléctricos.
CENTRO DE SERVICIO Y ATENCIÓN
Llame al 01 (800) 030-7777
IMPORTADO Y COMERCIALIZADO POR
TECHTRONIC INDUSTRIES, MÉXICO, SA DE CV
Av. President Masarik #29 piso 7, Col. Polanco V Sección
CP 11560, Deleg. Miguel Hidalgo, CDMX
Modelo:
Fecha de Compra:
Sello del Distribuidor:
58140126d1 01607300102Q-01(A)
08/18 Printed in China
MILWAUKEE TOOL
13135 West Lisbon Road
Brookeld, WI 53005 USA

Transcripción de documentos

OPERATOR'S MANUAL MANUEL de L'UTILISATEUR MANUAL del OPERADOR Cat. No. / No de cat. 0885-20 M18™ FUEL™ 3-in-1 BACKPACK VACUUM ASPIRATEUR DORSAL 3-en-1 M18™ FUEL™ ASPIRADORA DE MOCHILA 3-en-1 M18™ FUEL™ WARNING To reduce the risk of injury, user must read and understand operator's manual. AVERTISSEMENT Afin de réduire le risque de blessures, l'utilisateur doit lire et bien comprendre le manuel. ADVERTENCIA Para reducir el riesgo de lesiones, el usuario debe leer y entender el manual. IMPORTANT SAFETY INSTRUCTIONS USING AN ELECTRICAL VACUUM, TO REDUCE THE WARNING WHEN RISK OF FIRE OR INJURY, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ ALL INSTRUCTIONS BEFORE USING VACUUM. FOR HOUSEHOLD OR COMMERCIAL USE. BEFORE USING THE VACUUM, READ THIS OPERATOR’S MANUAL, BATTERY PACK AND CHARGER OPERATOR’S MANUALS, AND ALL LABELS ON THE VACUUM, BATTERY PACK, AND CHARGER. •Use special care when emptying heavily loaded WORK AREA SAFETY •Keep work area clean and well lit. Cluttered or tanks. •To avoid spontaneous combustion, empty tank dark areas invite accidents. •Do not use in the presence of explosive dust, after each use. •Do not leave vacuum unattended when battery liquids or vapors. •Do not use where oxygen or anesthetics are pack is installed. Remove battery pack when not in use and before servicing. used. •Do not allow to be used as a toy. Close attention •Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, is necessary when used by or near children. hair, and anything else that may reduce air flow. •Use extra care when using on stairs. •Static shocks are possible in dry areas or when ELECTRICAL SAFETY the relative humidity of the air is low. This is •Do not pick up wet material. Do not use water to only temporary and does not affect the use of the settle dust. vacuum. To reduce the frequency of static shocks, •Do not handle battery pack or vacuum with wet add moisture to the air with a console or installed hands. humidifier. •Store indoors. Do not expose to rain. •Some wood contains preservatives and can be toxic. Take extra care to prevent inhalation and PERSONAL SAFETY skin contact when working with these materials. •STAY ALERT. Watch what you are doing and use Request and follow any safety information available common sense. Do not use vacuum when you are from your material supplier. tired, distracted or under the influence of drugs, •Maintain vacuum. Check for misalignment or alcohol or medication causing diminished control. binding of moving parts, breakage of parts and •The operation of a vacuum can result in foreign any other condition that may affect the vacuum's objects being blown into eyes, which can result in operation. If damaged, have the vacuum repaired eye damage. Always wear safety goggles or glasses before use. Many accidents are caused by poorly with side shields when operating vacuum. maintained tools. •Wear a dust mask or use an OSHA compliant •Always use common sense and be cautious dust extraction solution when working in dusty when using tools. It is not possible to anticipate situations. Dust particles can harm your lungs. every situation that could result in a dangerous out•Avoid accidental starting. Ensure the switch is come. Do not use this tool if you do not understand in the off-position before inserting battery pack. these operating instructions or you feel the work is Inserting battery pack in vacuum that has the switch beyond your capability; contact Milwaukee Tool or on invites accidents. a trained professional for additional information or •Do not overreach. Keep proper footing and bal- training. ance at all times. This enables better control of the •Maintain labels and nameplates. These carry vacuum in unexpected situations. important information. If unreadable or missing, •Never stand on vacuum or use as a step stool. contact a MILWAUKEE service facility for a free •Keep hair, loose clothing, fingers, and all parts replacement. of body away from openings and moving parts. •This product is suitable for collection of silica •Use only as described in this manual. Use only dust when used in accordance with these inmanufacturer’s recommended attachments. structions. To reduce the risk of health hazards from other vapors or dust, do not vacuum USE AND CARE •Do not use without tank and/or filter properly carcinogenic, toxic or hazardous materials such as asbestos, arsenic, barium, beryllium, lead, installed. •Do not use to pick up flammable or combustible pesticides or other health endangered materials. Some dust created by liquids such as gasoline or use in areas where they • power sanding, sawing, may be present. •Do not pick up anything that is burning or smok- grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth ing such as cigarettes, matches, or hot ashes. •Do not pick up soot, cement, plaster or drywall defects or other reproductive harm. Some examples dust without filter in place. These are very fine of these chemicals are: particles that may affect the performance of the •lead from lead-based paint •crystalline silica from bricks and cement and other motor or be exhausted back into the air. •To reduce risk, do not use to vacuum hazard- masonry products, and ous, toxic or carcinogenic materials, such as •arsenic and chromium from chemically-treated lumber. asbestos or pesticide. WARNING 2 SYMBOLOGY Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles. • The unit is compliant as an objective data solution of OSHA Standard 29CRF 1926.1153, assuming it is used in accordance with MILWAUKEE instructions. Please reference https://www.osha.gov for further details on compliance methods. Visit https://www.milwaukeetool. com for an objective data sheet. Volts Direct Current Read operator's manual Wear eye protection BATTERY PACK USE AND CARE •Use vacuum only with specifically designated battery packs. Use of any other battery packs may create a risk of injury and fire. •Turn off all controls before removing battery pack. •Before using the battery pack or charger read the operator’s manuals, and any labels on the battery pack, charger and vacuum. •Recharge only with the charger specified by the manufacturer. A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack. •When battery pack is not in use, keep it away from other metal objects like paper clips, coins, keys, nails, screws, or other small metal objects that can make a connection from one terminal to another. Shorting the battery terminals together may cause burns or a fire. •Do not use damaged battery pack or vacuum. If battery pack or vacuum are not working as they should, have been dropped, damaged, left outdoors,or dropped into water, return them to a service center. C US UL Listing for Canada and U.S. SPECIFICATIONS Cat. No....................................................... 0885-20 Volts.............................................................. 18 DC Battery Type..................................................M18™ Charger Type................................................M18™ Air Volume...................................................55 CFM Sealed Suction............................................ 76inH20 Air Performance.................................. 159 air watts Capacity..............................................1 Gal. (3.8 L) Recommended Ambient Operating Temperature.......................0°F to 125°F Telescoping Extension Wand................ 14-37-0005 Flexible Hose......................................... 31-01-0305 Crevice Tool........................................... 31-01-0310 Floor Tool............................................... 31-01-0315 Dust Extraction Adapter......................... 31-01-0320 HEPA Filter............................................ 49-90-1963 9 Foot Accessory Hose......................... 49-90-1964 SERVICE •Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained. •Never service damaged battery packs. Service of battery packs should only be performed by the manufacturer or authorized service providers. SPECIFIC SAFETY RULES •Before using the vacuum, read this operator’s manual, your battery pack and charger operator’s manuals, and all labels on the vacuum, battery pack, and charger. •Never use vacuum without tank and filter properly installed. Vacuum will throw dust and debris into the air. •Never use water to clean filter. Tap clean or blow dirt off with compressed air. Water will cause filter to fail. •Wear ear protectors. Exposure to noise can cause hearing loss. READ AND SAVE ALL INSTRUCTIONS FOR FUTURE USE 3 FUNCTIONAL DESCRIPTION ASSEMBLY To reduce the risk of WARNING injury, always remove the battery pack before removing the tank. 1 CAUTION To remove the battery, push in the release buttons and pull the battery pack away from the tool. Always remove battery pack before changing or removing accessories. To insert the battery, slide the pack into the body of the tool. Make sure it latches securely into place. 2 WARNING 6 3 Removing/Installing the Filter To remove the filter: Tank 1. Remove the battery pack. cap 2. Press the tank handle button and remove the tank from the vacuum. Filter 3. Pull out tank cap to expose the filter. Pull the filter out of the tank. 4. Lift the tank release button and empty all the dust and debris from the tank. Tank 5. To clean the filter, tap clean or blow dirt off with compressed air. Replace the filter if damaged or suction decreases (single pack, Cat. No. 49-901963). NOTE: Never use water to Tank release clean filter. button To install the filter: 1. Place the filter into the top of the tank. 2. Line up the tank cap guides and secure it to the tank. Place the tank back into the vacuum. Only use accessories specifically recommended for this tool. Others may be hazardous. 5 4 7 8 9 10 11 13 The vacuum can be hung and mounted to a surface for ease of use. To mount the vacuum, remove the backpack plate according to the "Removing/Installing the Backpack Plate" instructions. This will expose the mounting hanger. Pull hanger away from the vacuum, unclip the hanger straps and hook vacuum onto surface. Secure by clipping the hanger straps and tightening to the surface. Keep filter clean. Efficiency of the vacuum is largely dependent on the filter. A dirty filter will reduce the air flow and overall efficiency of the system. Do not clean with water. Remove from tank and tap clean or blow off with compressed air. Removing/Inserting the Battery 12 Mounting the Vacuum • Flexible hose: Insert the accessory onto the vacuum inlet. Clip onto the hose clip to secure. 15 WARNING 17 Mounting hanger Flexible hose • Crevice tool: Hook the accessory onto the crevice tool rungs located on the lower backpack strap. Push the nose of the accessory through the lower rung and strap the top to the upper rung. • Dust extraction adapter: Hook the accessory onto the dust extraction adapter rung located on the lower backpack strap. Hanger straps Dust extraction adapter To unmount the vacuum, unhook the hanger straps. Pull hanger from the surface and push hanger back into the vacuum. Reinstall the backpack plate according to the "Removing/Installing the Backpack Plate" instructions. Crevice tool Removing/Installing the Backpack Plate OPERATION WARNING The backpack plate can be removed when mounting the vacuum on a surface or carrying by hand. To reduce the risk of fire To remove the plate, hold down the backpack plate and injury, do not use release button. Pull the bottom end of the plate away from the vacuum to remove the lower tabs. to pick up flammable or combustible materials. Pull down on the plate and away from the vacuum To reduce the risk of injury, wear safety goggles or glasses with side shields. Empty tank before to remove the upper tabs. use. Before use, ensure the filter is installed. Do not carry vacuum by the tank handle. CAUTION Starting, Stopping, and Controlling Speed Press the Power switch up to 2 to run the vacuum on High power. Press the Power switch down to 1 to run the vacuum on Low power. To turn the vacuum Off, return the Power switch to its home position. Removing/Installing the Accessories 14 To install the hose, push the accessory onto the vacuum inlet. To install the nozzles and extensions, push the accessory onto the hose end. To remove, press the accessory clip and pull out. 16 1. Carrying handle 2. Tank handle button 3. Tank 4. Battery bay 5. Hose clip 6. Vacuum inlet 7. Extension wand holder 8. Top backpack straps 9. Backpack plate 10. Lower backpack strap Storing the Accessories 11. Switch 12. Flexible hose 13. Telescoping extension wand 14. Floor tool 15. Dust extraction adapter 16. Crevice tool 17. HEPA filter Each of the accessories can be stored on the vacuum. Floor tool • Telescoping extension wand:Clip the accessory onto the extension wand holder. • Floor tool: Insert the accessory onto the top of the telescoping extension wand. Telescoping extension wand 4 Backpack plate release button Using the Vacuum To install the plate, line up and insert the upper There are multiple ways to use the vacuum to best plate tabs into the vacuum. Lift the plate up to align suit your job. and insert the lower plate tabs into the vacuum. • Wearing the vacuum as a backpack. Place Push the tabs in to lock. vacuum on body. Secure the tool by strapping in the top and bottom backpack straps. • Mounting the vacuum on a surface. Remove the backpack plate according to the "Removing/ Installing the Backpack Plate" instructions. Then mount the vacuum to the surface according to the "Mounting the Vacuum" instructions. • Carrying the vacuum in hand. If desired, remove the backpack plate according to the "Removing/ Installing the Backpack Plate" instructions. 5 ACCESSORIES WARNING Operation 1. Remove ALL dirt and debris found in the tank. 2. Insert battery pack and attach accessories. Use only recommended 3. Press the Power switch to the desired speed. accessories. Others Begin pick-up. 4. Turn off the vacuum immediately upon completing may be hazardous. For a complete listing of accessories, go online to a job or when tank is full and ready to be emptied. NOTE: If suction shuts off, turn off the vacuum www.milwaukeetool.com or contact a distributor. SERVICE - UNITED STATES immediately and empty the tank. 5. Remove battery pack. (1.800.729.3878) 6. Clean the interior of the tank and accessories Monday-Friday, 7:00 AM - 6:30 PM CST periodically. or visit www.milwaukeetool.com 1-800-SAWDUST Storage Before storing your vacuum, empty and clean the Contact Corporate After Sales Service Technical tank, filter, and accessories. Remove the battery Support with technical, service/repair, or warranty pack. questions. MAINTENANCE To reduce the risk of WARNING injury, always unplug Email: [email protected] Become a Heavy Duty Club Member at www.milwaukeetool.com to receive important notifications regarding your tool purchases. the charger and remove the battery pack from the charger or tool before performing any maintenance. Never disassemble the tool, battery pack or charger. Contact a MILWAUKEE service facility for ALL repairs. SERVICE - CANADA Milwaukee Tool (Canada) Ltd 1.800.268.4015 Monday-Friday, 7:00 AM - 4:30 PM CST or visit www.milwaukeetool.ca Maintaining Tool LIMITED WARRANTY USA & CANADA Keep your tool, battery pack and charger in good repair by adopting a regular maintenance program. Inspect your tool for issues such as undue noise, misalignment or binding of moving parts, breakage of parts, or any other condition that may affect the tool operation. Return the tool, battery pack, and charger to a MILWAUKEE service facility for repair. After six months to one year, depending on use, return the tool, battery pack and charger to a MILWAUKEE service facility for inspection. If the tool does not start or operate at full power with a fully charged battery pack, clean the contacts on the battery pack. If the tool still does not work properly, return the tool, charger and battery pack, to a MILWAUKEE service facility for repairs. To reduce the risk of personal injury and damage, never immerse your tool, battery pack or charger in liquid or allow a liquid to flow inside them. Every MILWAUKEE power tool* (see exceptions below) is warranted to the original purchaser only to be free from defects in material and workmanship. Subject to certain exceptions, MILWAUKEE will repair or replace any part on an electric power tool which, after examination, is determined by MILWAUKEE to be defective in material or workmanship for a period of five (5) years** after the date of purchase unless otherwise noted. Return of the power tool to a MILWAUKEE factory Service Center location or MILWAUKEE Authorized Service Station, freight prepaid and insured, is required. A copy of the proof of purchase should be included with the return product. This warranty does not apply to damage that MILWAUKEE determines to be from repairs made or attempted by anyone other than MILWAUKEE authorized personnel, misuse, alterations, abuse, normal wear and tear, lack of maintenance, or accidents. Normal Wear: Many power tools need periodic parts replacement and service to achieve best performance. This warranty does not cover repair when normal use has exhausted the life of a part including, but not limited to, chucks, brushes, cords, saw shoes, blade clamps, o-rings, seals, bumpers, driver blades, pistons, strikers, lifters, and bumper cover washers. *This warranty does not cover Air Nailers & Staplers; Airless Paint Sprayer; Cordless Battery Packs; Gasoline Driven Portable Power Generators; Hand Tools; Hoist – Electric, Lever & Hand Chain; M12™ Heated Gear; Reconditioned Product; and Test & Measurement Products. There are separate and distinct warranties available for these products. **The warranty period for Job Site Radios, M12™ Power Port, M18™ Power Source, Jobsite Fan and Trade Titan™ Industrial Work Carts is one (1) year from the date of purchase. The warranty period for the Drain Cleaning Cables is two (2) years from the date of purchase. The warranty period for the M18™ Compact Heat Gun and the 8 Gallon Dust Extractor is three (3) years from the date of purchase. The warranty period for the LED in the LED Work Light and the LED Upgrade Bulb for the Work Light is the lifetime of the product subject to the limitations above. If during normal use the LED or LED Bulb fails, the part will be replaced free of charge. Warranty Registration is not necessary to obtain the applicable warranty on a MILWAUKEE power tool product. The manufacturing date of the product will be used to determine the warranty period if no proof of purchase is provided at the time warranty service is requested. ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT REMEDIES DESCRIBED HEREIN IS A CONDITION OF THE CONTRACT FOR THE PURCHASE OF EVERY MILWAUKEE PRODUCT. IF YOU DO NOT AGREE TO THIS CONDITION, YOU SHOULD NOT PURCHASE THE PRODUCT. IN NO EVENT SHALL MILWAUKEE BE LIABLE FOR ANY INCIDENTAL, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, OR FOR ANY COSTS, ATTORNEY FEES, EXPENSES, LOSSES OR DELAYS ALLEGED TO BE AS A CONSEQUENCE OF ANY DAMAGE TO, FAILURE OF, OR DEFECT IN ANY PRODUCT INCLUDING, BUT NOT LIMITED TO, ANY CLAIMS FOR WARNING Cleaning Clean dust and debris from vents. Keep handles clean, dry and free of oil or grease. Use only mild soap and a damp cloth to clean, since certain cleaning agents and solvents are harmful to plastics and other insulated parts. Some of these include gasoline, turpentine, lacquer thinner, paint thinner, chlorinated cleaning solvents, ammonia and household detergents containing ammonia. Never use flammable or combustible solvents around tools. Repairs For repairs, return the tool, battery pack and charger to the nearest service center. 6 RÈGLES GÉNÉRALES DE SÉCURITÉ LOSS OF PROFITS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES, WRITTEN OR ORAL. TO THE EXTENT PERMITTED BY LAW, MILWAUKEE DISCLAIMS ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE; TO THE EXTENT SUCH DISCLAIMER IS NOT PERMITTED BY LAW, SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY AS DESCRIBED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU, THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. This warranty applies to product sold in the U.S.A. and Canada only. Please consult the ‘Service Center Search’ in the Parts & Service section of MILWAUKEE’s website www.milwaukeetool.com or call 1.800. SAWDUST (1.800.729.3878) to locate your nearest service facility for warranty and non-warranty service on a Milwaukee electric power tool. AVERTISSEMENT DLORSE L’UTILISATION D’UN ASPIRATEUR ELECTRIQUE ET AFIN DE MINIMISER LE RISQUE D’INCENDIE OU BLESSURES, IL FAUT TOUJOURS PRENDRE DES PRECAUTIONS ELEMENTAIRES, Y COMPRIS CELLES PRESENTEES CI-DESSOUS : LIRE TOUTES LES INSTRUCTIONS AVANT D'UTILISER L’ASPIRATEUR. POUR DES APPLICATIONS COMMERCIALES OU RESIDENTIELLES. AVANT D’UTILISER L’ASPIRATEUR, LIRE LE PRÉSENT MANUEL D’UTILISATION, LE MANUEL D’UTILISATION DU BLOC-PILES ET DU CHARGEUR, AINSI QUE TOUTES LES ÉTIQUETTES SE TROUVANT SUR L’ASPIRATEUR, LE BLOC-PILES, ET LE CHARGEUR. SÉCURITÉ DU LIEU DE TRAVAIL LIMITED WARRANTY - MEXICO, CENTRAL AMERICA & CARIBBEAN TECHTRONIC INDUSTRIES' warranty is for 5 years since the original purchase date. This warranty card covers any defect in material and workmanship on this Product. To make this warranty valid, present this warranty card, sealed/ stamped by the distributor or store where you purchased the product, to the Authorized Service Center (ASC). Or, if this card has not been sealed/stamped, present the original proof of purchase to the ASC. Call toll-free1 01 (800) 030-7777 to find the nearest ASC, for service, parts, accessories or components. Procedure to make this warranty valid Take the product to the ASC, along with the warranty card sealed/ stamped by the distributor or store where you purchased the product, and any faulty piece or component will be replaced without cost for you. We will cover all freight costs relative with this warranty process. Exceptions This warranty is not valid in the following situations a) When the product is used in a different manner from the end-user guide or instruction manual. b) When the conditions of use are not normal. c) When the product was modified or repaired by people not authorized by TECHTRONIC INDUSTRIES. Note: If cord set is damaged, it should be replaced by an Authorized Service Center to avoid electric risks. SERVICE AND ATTENTION CENTER Call to 01 (800) 030-7777 IMPORTED AND COMMERCIALIZED BY TECHTRONIC INDUSTRIES MEXICO, SA DE CV Av President Masarik #29 piso 7, Col. Polanco V Sección CP 11560, Deleg. Miguel Hidalgo, CDMX •Veillez à ce que l’aire de travail soit propre et bien éclairée. Le désordre et le manque de lumière favorisent les accidents. •Ne pas utiliser en présence de liquides explosifs ou de poussière ou vapeurs explosives. •Ne pas utiliser où l'oxygène ou les agents anesthésiques sont utilisés. •Cet appareil n’est pas un jouet. Une surveillance étroite est impérative lorsqu’il est utilisé par des enfants ou à leur proximité. •Redoubler de prudence lors de l'utilisation dans des escaliers. Model: SÉCURITÉ ÉLECTRIQUE Date of Purchase: •Ne pas aspirer de matériaux humides. Ne pas utiliser d’eau pour déposer la poussière. •Ne pas manipuler le bloc-pile ou l’aspirateur avec les mains mouillées. •Entreposer à l’intérieur. Ne pas exposer à la pluie. Distributor or Store Stamp: SÉCURITÉ INDIVIDUELLE 7 •RESTER VIGILANT. Se montrer attentif et faire preuve de bon sens. Ne pas utiliser l’aspirateur en cas de fatigue, distraction ou sous l’influence de l’alcool, de drogues ou de médicaments causant la perte de contrôle. •L’utilisation d'un aspirateur peut causer la projection d’objets en direction du visage et entraîner des lésions oculaires. Toujours porter des lunettes de sécurité ou des lunettes avec écrans latéraux lors de l’utilisation de l’aspirateur. •Porter un masque anti-poussière ou utiliser une solution d'extraction de poussière conforme aux normes de l'OSHA pendant que vous travaillez dans des circonstances poussièreuses. Les particules de poussière peuvent nuire vos poumons. •Éviter les démarrages accidentels. S'assurer l'utilisation. Beaucoup d'accidents sont causés par que l’interrupteur est en position d’arrêt avant des outils mal entretenus. d’insérer le bloc-piles. L’insertion du bloc-piles •Toujours faire preuve de bons sens et procéder quand l’interrupteur de l’aspirateur est en position avec prudence lors de l’utilisation d’outils. C’est impossible de prévoir toutes les situations dont le de marche augmente le risque d’accidents. •Ne pas travailler hors de portée. Toujours se te- résultat est dangereux. Ne pas utiliser cet outil si vous nir bien campé et en équilibre. Une bonne stabilité ne comprenez pas ces instructions d’opération ou si procure un meilleur contrôle de l’aspirateur en cas vous pensez que le travail dépasse votre capacité ; veuillez contacter Milwaukee Tool ou un professionnel d’imprévus. •Ne jamais monter sur l’aspirateur ou s’en servir formé pour recevoir plus d’information ou formation. •Maintenir en état les étiquettes et les plaques comme marchepied. •Garder les cheveux, les vêtements amples, les signalétiques. Des informations importantes y doigts ainsi que toutes les parties du corps à l’écart figurent. Si elles sont illisibles ou manquantes, des ouvertures et des pièces en mouvement. contacter un centre de service et d’entretien •Utiliser exclusivement selon les instructions de MILWAUKEE pour un remplacement gratuit. ce manuel. Utiliser exclusivement les accessoires •Ce produit convient à la collecte de la poussière de silice lorsqu'il est utilisé conformément à ces recommandés par le fabricant. instructions. Afin de réduire les risques pour la UTILISATION ET ENTRETIEN santé issus de autres vapeurs ou de poussières, DE L’OUTIL ÉLECTRIQUE ne pas aspirer de matières toxiques, cancérigènes •Ne pas utiliser l'aspirateur sans avoir le réservoir ou autres matières dangereuses comme l'amiante, et/ou le filtre correctement installés. l'arsenic, le baryum, le béryllium, le plomb, les pesti•Ne pas utiliser l’appareil pour ramasser des cides ou autres matières pouvant mettre en danger liquides inflammables ou combustibles tels que la santé. l’essence, ou dans des environnements où il est • possible de retrouver ce type de liquide. •Ne pas aspirer d’éléments qui brûlent ou qui La poussière dégagée par certains matériaux lors fument comme des cigarettes, des allumettes ou du ponçage, sciage, meulage, perçage et autres des cendres chaudes. opérations de construction contient des produits •Ne pas aspirer de la suie, du ciment, du plâtre ou chimiques reconnus pour causer le cancer, des de la poussière de cloison sèche sans le filtre en malformations congénitales ou des lésions de place. Il y a des particules très fines qui peuvent affect- l’appareil reproducteur. Voici certains exemples de er le rendement du moteur ou s’échapper dans l’air. ces produits chimiques : •Afin de minimiser les risques, ne pas l’utiliser •le plomb contenu dans la peinture au plomb, pour aspirer de matériaux dangereux, toxiques ou carcinogéniques tels que l’amiante ou les •la silice cristalline contenue dans les briques, le ciment et d'autres produits de maçonnerie, et pesticides. •Faire preuve d’une extrême prudence en vidant •l'arsenic et le chrome contenus dans le bois de construction traité par produits chimiques. les réservoirs fortement chargés. •Pour prévenir la combustion spontanée, vider le Le risque présenté par l’exposition à ces produits varéservoir de poussière après chaque utilisation. rie en fonction de la fréquence de ce type de travail. •Ne pas laisser l’aspirateur sans surveillance lorsque Pour réduire l’exposition à ces produits chimiques le bloc-pile est installé. Retirer le bloc-pile lorsque ce- : travailler dans un endroit bien aéré et utiliser des lui-ci n’est pas utilisé et avant de procéder à son entretien. équipements de sécurité approuvés tels que les •Ne placer aucun objet dans les ouvertures. Ne masques anti-poussière spécialement conçus pour pas utiliser le produit si l’une ou l’autre des ouver- filtrer les particules microscopiques. tures est obstruée. Enlever toute la poussière, toutes • L’unité est conforme, comme une solution de résuobjectifs, à la norme OSHA 29CRF 1926.1153 les peluches et tous les cheveux, ou tout autre élé- ltats lorsqu’elle est utilisée sans un aspirateur de ment pouvant réduire la circulation de l’air. poussière, en supposant qu’elle est utilisé selon •C’est possible que les décharges statiques se les instructions de MILWAUKEE. Veuillez consulter passent dans des endroits humides ou bien, le site d’Internet https://www.osha.gov pour en quand l’humidité relative de l’air est basse. Ceci savoir plus à propos des méthodes de conformité. est temporel et n’affectera pas la performance de Veuillez consulter https://www.milwaukeetool.com l’aspirateur. Afin de minimiser la fréquence des pour consulter les fiches techniques complètes. décharges statiques, ajouter de l’humidité à l’air à UTILISATION ET ENTRETIEN l’aide d’une console ou un humidificateur installé. •Certains types de bois contiennent des conDE LA BATTERIE servateurs et pourront donc être toxiques. •N’utiliser l’aspirateur qu’avec des bloc-piles Redoubler la prudence afin d’éviter leur inhala- recommandés. L’utilisation de tout autre bloc-piles tion et leur contact avec votre peau lorsque des peut créer un risque de blessures et d’incendie. travaux sont faits avec ces matériaux. Demander •Arrêter toutes les commandes avant de retirer au fabricant du matériel toutes les informations de le bloc-piles. sécurité disponibles et veuillez les suivre. •Pour réduire le risque de choc électrique, ne pas •Entretien de l’aspirateur. Vérifier qu'aucune utiliser sur une surface mouillée. Ne pas exposer pièce mobile n'est mal alignée ou bloquée, l’appareil à la pluie. Entreposer à l’intérieur. qu'aucune pièce n'est brisée et s'assurer •Avant d’utiliser le bloc-pile ou le chargeur, lire qu'aucun autre problème ne risque d'affecter les manuels d’utilisation et toutes les étiquettes le bon fonctionnement de l’aspirateur. En cas sur le bloc-piles, le chargeur et l’aspirateur. de dommages, faire réparer l’aspirateur avant AVERTISSEMENT 8 DESCRIPTION FONCTIONNELLE •Pour recharger le bloc-piles, utiliser seulement le chargeur spécifié par le fabricant. Un chargeur pouvant convenir à un type de bloc-piles peut entraîner un risque d’incendie lorsqu’il est utilisé avec un autre type de bloc-piles. •Lorsque le bloc-piles n’est pas utilisé, le tenir éloigné des objets en métal tels que les trombones, les pièces de monnaie, les clés, les clous, les vis ou d’autres petits objets métalliques qui pourraient connecter les bornes. Le courtcircuitage des bornes d’une batterie peut entraîner des brûlures ou un incendie. •Ne pas utiliser un bloc-pile ou un aspirateur endommagé. Si le bloc-piles ou l’aspirateur ne fonctionne pas correctement, s’ils ont été tombés par terre, s’ils sont endommagés, s’ils ont été laissés à l’extérieur ou s’ils sont tombés dans l’eau, retournez-les au centre de service. 1 2 ENTRETIEN 6 3 •Les réparations de l’outil électrique doivent être confiées à un technicien qualifié, utilisant exclusivement des pièces identiques à celles d’origine. Le maintien de la sûreté de l’outil électrique sera ainsi assuré. •Ne jamais effectuer la réparation d’un bloc-piles endommagé. La réparation du bloc-piles doit être réalisée par le fabricant ou les fournisseurs de service agréés uniquement. 5 4 7 REGLAS ESPECIFICAS DE SEGURIDAD 8 •Avant d’utiliser l’aspirateur, lire le présent manuel d’utilisation, le manuel d’utilisation du bloc-piles et du chargeur, ainsi que toutes les étiquettes se trouvant sur l’aspirateur, le blocpiles et le chargeur. •Ne jamais utiliser l'aspirateur sans avoir le réservoir et le filtre correctement installés. L’aspirateur éjectera de la poussière et du débris dans l’air. •Ne jamais utiliser de l’eau pour nettoyer le filtre. Nettoyer en frappant ou en soufflant la saleté avec de l’air comprimé. L’eau provoquera des échecs dans le filtre. •Porter des protecteurs d’oreille. L’exposition au bruit peut entraîner une perte auditive. 12 9 10 11 13 LIRE TOUTES LES INSTRUCTIONS ET LES CONSERVER À DES FINS DE RÉFÉRENCE ULTÉRIEURE 15 14 16 1. Poignée de transport 2. Bouton d'activation du réservoir 3. Réservoir 4. Compartiment des piles 5. Clip de tuyau 6. Entrée de l’aspirateur 7. Support prolongateur de la lance 8. Sangles supérieures du sac à dos 9. Plaque de sac à dos 9 17 10.Sangle inférieure du sac à dos 11. Interrupteur 12. Tuyau flexible 13. Rallonge télescopique pour lance 14. Outil pour plancher 15. Adaptateur de dépoussiérage 16. Suceur plat 17. Filtre HEPA SPÉCIFICATIONS Retrait/Installation du filtre Pour enlever le filtre : 1. Retirer le bloc-piles. Couvercle du réservoir 2. Appuyer su r l e bouton d'activation du réservoir et enlever le réservoir de Filtre l’aspirateur. 3. Faire sortir le couvercle du réservoir pour exposer le tuyau. Retirer le filtre du réservoir. Réservoir 4. Relever le bouton de déverrouillage du réservoir et vider toute la poussière et le débris dans le réservoir. 5. Pour nettoyer le filtre, veuillez le taper ou souffler Bouton de déverrouillage la poussière à l'aide de l’air du réservoir comprimé. Changer le filtre s’il est endommagé ou si l’aspiration est réduite (seul paquet ; Nº de cat.: 49-90-1963). REMARQUE : Ne jamais utiliser d’eau pour nettoyer le filtre. Pour installer le filtre : 1. Mettre le filtre dans la partie supérieure du réservoir. 2. Aligner les guides sur le couvercle du réservoir et le fixer sur place. Remettre le réservoir dans l’aspirateur. No de Cat................................................... 0885-20 Volts.............................................................. 18 CD Type de batterie ...........................................M18™ Type de chargeur .........................................M18™ Volume d’air..............................55 pi3/min (55 CFM) Aspiration jointive............................. 193,0 cm (76") Débit d'air................................................. 159 watts Capacité..............................................3,8 L (1 Gal.) Température ambiante de fonctionnement recommandée ........... -18°C à 50°C (0°F à 125°F) Rallonge télescopique pour lance......... 14-37-0005 Tuyau flexible........................................ 31-01-0305 Suceur plat............................................ 31-01-0310 Outil pour plancher................................ 31-01-0315 Adaptateur de dépoussiérage............... 31-01-0320 Filtre HEPA............................................ 49-90-1963 Tuyau accessoire de 2,7 m (9’)............. 49-90-1964 PICTOGRAPHIE Volts Courant direct Lire le manuel d’utilisation C Support de l’aspirateur • Tuyau flexible : Insérer l'accessoire dans l’entrée de l'aspirateur. Utiliser le clip de tuyau pour le fixer. C'est possible d’accrocher l’aspirateur et le monter sur une surface pour faciliter son utilisation. Pour monter l’aspirateur, enlever la plaque de sac à dos selon les consignes dans la section « Enlèvement/installation de la plaque de sac à dos ». Ceci exposera le support de fixation. Tirer sur le support pour le faire sortir de l’aspirateur, retirer les supports dans les sangles du support et attacher l’aspirateur sur une surface. Veuillez l'attacher en fixant les sangles du support et les serrant sur la surface. Support de fixation Tuyau flexible • Suceur plat : Attacher l'accessoire sur les barreaux du suceur plat qui se trouvent sur la sangle inférieure du sac à dos. Appuyer sur le nez de l'accessoire pour le faire passer à travers du barreau inférieur et attacher la partie supérieure sur le barreau supérieur. • Adaptateur de dépoussiérage : Attacher l'accessoire sur le barreau de l’adaptateur de dépoussiérage trouvé dans la sangle inférieure du sac à dos. Sangles du support Adaptateur de dépoussiérage Pour démonter l'aspirateur, retirer les sangles du support. Tirer sur le support qui se trouve dans la surface et le remettre dans l’aspirateur. Remettre la plaque de sac à dos selon les consignes dans la section « Enlèvement/installation de la plaque de sac à dos ». AVERTISSEMENT Toujours porter une protection oculaire Utiliser seulement des accessoires spécialement recommandés pour cet outil. L’utilisation d’autres types d’accessoires pourrait entraîner UL Listing Mark pour des situations dangereuses. US Canada et États-unis Installation / Retrait des accessoires MONTAGE DE L'OUTIL Pour installer le tuyau, appuyer sur l’accessoire pour le faire entrer dans l’entrée de l’aspirateur. Pour installer les buses et les extensions, appuyer sur l'accessoire pour le faire entrer dans le bout de tuyau. Pour l’enlever, appuyer sur le clip de l’accessoire et le retirer. AVERTISSEMENT Afin de réduire les risques de blessures, toujours retirer le bloc-piles avant de retirer le réservoir. Rangement des accessoires MISE EN GARDE Garder le filtre propre. L’efficacité de l’aspirateur C'est possible de ranger dans l'aspirateur tous les accessoires. • Rallonge télescopique pour lance : Utiliser un clip pour attacher l’accessoire sur le support prolongateur de la lance. • Outil pour plancher : Insérer l’accessoire dans la partie supérieure de la rallonge télescopique pour lance. dépend en grande partie du filtre. Un filtre sale réduit la circulation de l’air ainsi que l’efficacité globale du système. Ne pas utiliser de l’eau. Le retirer du réservoir et le nettoyer en frappant ou en soufflant avec de l’air comprimé. Insertion et retrait de la pile Pour retirer la pile, appuyer sur les boutons de relâchement et extraire le bloc-piles de l’outil. AVERTISSEMENT Retirer toujours le bloc-piles avant de changer ou de retirer les accessoires. Pour insérer la pile, la glisser dans le corps de l’outil. S’assurer qu’il y est bien inséré en place. 10 Outil pour plancher Rallonge télescopique pour lance Suceur plat MANIEMENT Enlèvement/installation de la plaque de sac à dos AVERTISSEMENT C'est possible d’enlever la plaque de sac à dos lorsque l’aspirateur est monté sur une surface ou bien, que vous le portez par la main. Pour enlever la plaque, appuyer le bouton de déverrouillage de la plaque de sac à dos et le tenir enfoncé. Tirer sur le bout inférieur de la plaque et le faire sortir de l’aspirateur afin d’enlever les languettes inférieures. Baisser la plaque et l’enlever de l’aspirateur pour enlever les languettes inférieures. Afin de réduire le risque d'incendie et de blessure, ne pas utiliser pour ramasser des matières inflammables. Pour réduire le risque de blessure, porter des lunettes de sécurité ou des lunettes avec écrans latéraux. Vider le réservoir avant utilisation. Avant de son utilisation, veuillez s’assurer que le filtre soit installé. AVERTISSEMENT Ne pas amener l’aspirateur par la poignée du réservoir. Démarrage, arrête et contrôle de vitesse Glisser le commutateur de démarrage vers le haut pour le régler dans la position 2 afin de démarrer l’aspirateur à haute puissance. Glisser le commutateur de démarrage vers le bas pour le régler dans Bouton de déverrouillage de la plaque de sac à dos la position 1 afin de démarrer l’aspirateur à puissance faible. Pour arrêter l’aspirateur, remettre le commuPour installer la plaque, aligner et insérer tateur de démarrage dans sa position initiale. les languettes supérieures de la plaque dans l’aspirateur. Relever la plaque pour aligner et insérer les languettes inférieures de la plaque dans l’aspirateur. Appuyer sur les languettes pour les verrouiller. 11 AVERTISSEMENT Pour minimiser les risques de blessures ou de Utilisation de l’aspirateur L’aspirateur peut être utilisé des nombreuses façons qui conviennent le mieux au travail que vous ferez. • Porter l’aspirateur comme un sac à dos. Mettre l’aspirateur sur votre corps. Attacher l’outil en utilisant les sangles supérieures et inférieures du sac à dos. • Montage de l’aspirateur sur une surface. Enlever la plaque de sac à dos selon les consignes dans la section « Enlèvement/installation de la plaque de sac à dos ». Après, monter l’aspirateur sur la surface selon les consignes dans la section « Montage de l’aspirateur ». • Emporter l’aspirateur à main. Enlever, au besoin, la plaque de sac à dos selon les consignes dans la section « Enlèvement/installation de la plaque de sac à dos ». dommages à l'outil, n'immergez jamais l'outil, la batterie ou le chargeur et ne laissez pas de liquide s'y infiltrer. Nettoyage Débarrassez les évents des débris et de la poussière. Gardez les poignées propres, à sec et exemptes d’huile ou de graisse. Le nettoyage doit se faire avec un linge humide et un savon doux. Certains nettoyants tels l’essence, la térébenthine, les diluants à laque ou à peinture, les solvants chlorés, l’ammoniaque et les détergents d’usage domestique qui en contiennent pourraient détériorer le plastique et l’isolation des pièces. Ne laissez jamais de solvants inflammables ou combustibles auprès des outils. Fonctionnement Réparations 1. Retirer TOUTE la poussière et TOUT le débris qui se trouvent dans le réservoir. 2. Insérer le bloc-piles et attacher les accessoires. 3. Régler le commutateur de démarrage dans la vitesse souhaitée. Le relever. 4. Arrêter l’aspirateur immédiatement après l'achèvement de votre travail ou bien, quand le réservoir soit plein et prêt pour le vider. REMARQUE : Si l’aspiration est interrompue, arrêter l’aspirateur immédiatement et vider le réservoir. 5. Retirer le bloc-piles. 6. Nettoyer l’intérieur du réservoir et les accessoires périodiquement. Pour les réparations, retournez outil, batterie et chargeur en entier au centre-service le plus près. ACCESOIRES AVERTISSEMENT L’utilisation d’autres accessoires que ceux qui sont spécifiquement recommandés pour cet outil peut comporter des risques. Pour une liste complète des accessoires, visiter le site internet www.milwaukeetool.com ou contactez un distributeur. SERVICE - CANADA Milwaukee Tool (Canada) Ltd 1.800.268.4015 Entreposage Avant d’entreposer l’aspirateur, vider et nettoyer le réservoir, le filtre et les accessoires. Retirer la pile. ENTRETIEN Monday-Friday, 7:00 AM - 4:30 PM CST www.milwaukeetool.ca GARANTIE LIMITÉE AUX ÉTATS-UNIS ET AU CANADA AVERTISSEMENT Pour minimiser les risques de blessures corpo- Chaque outil électrique* MILWAUKEE (voir exceptions ci-dessous) est garanti à l’acheteur d’origine uniquement pour être exempt de vices de matériaux et de fabrication. Sous réserve de certaines exceptions, MILWAUKEE réparera ou remplacera toute pièce d’un outil électrique qui, après examen par MILWAUKEE, s’est avérée être affectée d’un vice de matériau ou de fabrication et ce pendant une période de cinq (5) ans** à compter de la date d’achat, sauf indication contraire. Retourner l’outil électrique à un centre de réparation en usine MILWAUKEE ou à un poste d’entretien agréé MILWAUKEE, en port prépayé et assuré. Une copie de la preuve d’achat doit être présentée lors du retour du produit. Cette garantie ne couvre pas les dommages que MILWAUKEE détermine être causés par des réparations ou des tentatives de réparation par quiconque autre que le personnel agréé par MILWAUKEE, ou par des utilisations incorrectes, des altérations, des utilisations abusives, une usure normale, une carence d’entretien ou des accidents. Usure normale : Plusieurs outils électriques requièrent un remplacement et un entretien périodique de leurs pièces pour un meilleur rendement. Cette garantie ne couvre pas la réparation des pièces due à l’utilisation normale de l’outil, y compris, mais sans s’y limiter, les mandrins, les brosses, les cordes, les sabots de scie, les portelames, les joints toriques, les joints, les amortisseurs, les lames d’entraînement, les pistons, les percuteurs, les crochets et les rondelles à couvercle amortisseur. *Cette garantie ne s’applique pas aux cloueuses-agrafeuses pneumatiques, aux pulvérisateurs à peinture sans air, aux blocs-piles pour outils sans fil, aux génératrices d’alimentation portatives à essence, aux outils à main, aux monte-charges – électriques, à levier et à chaîne, aux vestes chauffantes M12™, aux produits ré-usinés, ni aux produits d’essai et de mesure. Il existe des garanties séparées distinctes pour ces produits. **La période de garantie applicable pour les radios de chantier, le port d’alimentation M12™, la source électrique M18™, le ventilateur de chantier et les chariots de travail industriels Trade Titan™ est d’une durée d’un (1) an à compter de la date d’achat. La période de garantie pour les Câbles de nettoyage des canalisations est de deux (2) ans à compter de la date d’achat. La période de garantie pour le relles, débranchez le chargeur et retirez la batterie du chargeur ou de l’outil avant d’y effectuer des travaux d’entretien. Ne démontez jamais l’outil, la batterie ou le chargeur. Pour toute réparation, consultez un centre de service MILWAUKEE accrédité. Entretien de l’outil Gardez l’outil en bon état en adoptant un programme d’entretien ponctuel. Inspectez votre outil pour des questions telles que le bruit excessif, de grippage des pièces mobiles, de pièces cassées ou toute autre condition qui peut affecter le fonctionnement de l'outil. Retournez votre outil à un centre de service MILWAUKEE accrédité pour obtenir le service. Après une période pouvant aller de 6 mois à un an, selon l’usage, retournez votre outil à un centre de service MILWAUKEE accrédité pour d'inspection. Si l’outil ne démarre pas ou ne fonctionne pas à pleine puissance alors qu’il est branché sur une batterie complètement chargée, nettoyez les points de contact entre la batterie et l’outil. Si l’outil ne fonctionne toujours pas correctement, renvoyez l’outil, le chargeur et la batterie à un centre de service MILWAUKEE accrédité. 12 Pistolet thermique compact M18™ et Dépoussiéreur de 8 gallons est de trois (3) ans à compter de la date d’achat. La période de garantie couvrant la DEL de la lampe de travail à DEL et l’ampoule améliorée à DEL de la lampe de travail est une garantie à vie du produit soumise aux limitations ci-dessus. En cas de défaillance de la DEL ou de l’ampoule à DEL pendant son utilisation normale, la pièce défaillante sera remplacée gratuitement. L’enregistrement de la garantie n’est pas nécessaire pour bénéficier de la garantie en vigueur sur un outil électrique MILWAUKEE. La date de fabrication du produit servira à établir la période de garantie, si aucune preuve d’achat n’est fournie lorsqu’une demande de service sous garantie est déposée. L’ACCEPTATION DES RECOURS EXCLUSIFS DE RÉPARATION ET DE REMPLACEMENT DÉCRITS DANS LES PRÉSENTES EST UNE CONDITION DU CONTRAT D’ACHAT DE TOUT PRODUIT MILWAUKEE. SI VOUS N’ACCEPTEZ PAS CETTE CONDITION, VOUS NE DEVEZ PAS ACHETER LE PRODUIT. EN AUCUN CAS, MILWAUKEE NE SAURAIT ÊTRE RESPONSABLE DE TOUT DOMMAGE ACCESSOIRE, SPÉCIAL OU INDIRECT, DE DOMMAGES-INTÉRÊTS PUNITIFS OU DE TOUTE DÉPENSE, D’HONORAIRES D’AVOCAT, DE FRAIS, DE PERTE OU DE DÉLAIS ACCESSOIRES À TOUT DOMMAGE, DÉFAILLANCE OU DÉFAUT DE TOUT PRODUIT, Y COMPRIS NOTAMMENT LES PERTES DE PROFIT. CERTAINS ÉTATS ET PROVINCES NE PERMETTANT L'EXCLUSION OU LA LIMITATION DES DOMMAGES DIRECTS OU INDIRECTS, LES RESTRICTIONS CI-DESSUS PEUVENT NE PAS VOUS ÊTRE APPLICABLES. CETTE GARANTIE EST EXCLUSIVE ET REMPLACE TOUTE AUTRE GARANTIE EXPRESSE, QU’ELLE SOIT VERBALE OU ÉCRITE. DANS LA MESURE PERMISE PAR LA LOI, MILWAUKEE RENONCE À TOUTE GARANTIE IMPLICITE, Y COMPRIS, MAIS SANS S’Y LIMITER, TOUTE GARANTIE IMPLICITE DE QUALITÉ MARCHANDE OU D’ADAPTATION À UNE UTILISATION OU À UNE FIN PARTICULIÈRE. DANS LA MESURE OÙ UNE TELLE STIPULATION D’EXONÉRATION N’EST PAS PERMISE PAR LA LOI, LA DURÉE DE CES GARANTIES IMPLICITES EST LIMITÉE À LA PÉRIODE APPLICABLE DE LA GARANTIE EXPRESSE, TEL QUE CELA EST DÉCRIT PRÉCÉDEMMENT. CERTAINS ÉTATS ET PROVINCES NE PERMETTANT PAS DE LIMITATION DE DURÉE DES GARANTIES IMPLICITES, LES RESTRICTIONS CI¬DESSUS PEUVENT DONC NE PAS VOUS ÊTRE APPLICABLES. LA PRÉSENTE VOUS CONFÈRE DES DROITS LÉGAUX PARTICULIERS; VOUS BÉNÉFICIEZ ÉGALEMENT D’AUTRES DROITS QUI VARIENT D’UN ÉTAT À UN AUTRE. Cette garantie s’applique aux produits vendus aux États-Unis et au Canada uniquement. Veuillez consulter la rubrique Centre SAV Milwaukee, dans la section Pièces et Services du site Web de MILWAUKEE, à l’adresse www.milwaukeetool.com, ou composer le 1-800-SAWDUST (1800-729-3878) afin de trouver le centre de service de votre région le plus proche pour l’entretien, sous garantie ou non, de votre outil électrique Milwaukee. CENTRE DE RÉPARATIONS ET DE SERVICE Composer le 01 (800) 030-7777 IMPORTÉ ET COMMERCIALISÉ PAR TECHTRONIC INDUSTRIES, MEXIQUE, SA DE CV Av President Masarik #29 piso 7, Col. Polanco V Sección CP 11560, Deleg. Miguel Hidalgo, CDMX Modèle : Date d’achat : Sceau du distributeur ou du magasin : REGLAS DE SEGURIDAD GENERALES PARA DISADVERTENCIA MINUIR EL RIESGO DE INCENDIO O LESIÓN AL USAR UNA ASPIRADORA ELÉCTRICA, SIEMPRE DEBE SEGUIR LAS PRECAUCIONES BÁSICAS, INCLUIDAS LAS SIGUIENTES: LEA TODAS LAS INSTRUCCIONES ANTES DE USAR LA ASPIRADORA. PARA USO DOMÉSTICO O COMERCIAL. ANTES DE UTILIZAR LA ASPIRADORA, LEA ESTE MANUAL DEL OPERADOR, LOS MANUALES DE LA BATERÍA Y EL CARGADOR Y TODAS LAS ETIQUETAS DE LA ASPIRADORA, LA BATERÍA Y EL CARGADOR. GARANTIE LIMITÉE – MEXIQUE, AMÉRIQUE CENTRALE ET CARAÏBES SEGURIDAD EN EL ÁREA TECHTRONIC INDUSTRIES' garantit le produit pendant 5 ans à partir DE TRABAJO de la date d’achat d’origine. •Mantenga el área de trabajo limpia y bien iluminada. Las áreas desordenadas u oscuras son propicias para los accidentes. •No se utilice en presencia de polvo, líquidos o vapores explosivos. •No se utilice donde se use oxígeno o anestésicos. •No permita que se use como un juguete. Es necesario prestar mucha atención cuando lo usen niños o cuando se use cerca de ellos. •Sea particularmente cuidadoso al usarlo en escaleras. Le présent bon de garantie couvre tous les vices de matériau et de fabrication que peut afficher ce produit. Pour assurer la validité de la présente garantie, veuillez présenter ce bon de garantie, estampillé du sceau du distributeur ou du magasin où le produit a été acheté, au centre de réparations agréé. Si le bon de garantie n’a pas été estampillé, veuillez fournir la preuve d’achat d’origine au centre de réparations agréé. Pour un entretien des pièces, des accessoires ou des composants, composer sans frais le 1-800-030-7777 afin d’obtenir les coordonnées du centre de réparations agréé le plus près Procédure pour assurer la validité de la garantie Présenter le produit au centre de réparations agréé, accompagné du bon de garantie estampillé du sceau du distributeur ou du magasin où le produit a été acheté. Toute pièce défectueuse ou tout composant défectueux sera remplacé(e) sans frais. Milwaukee assume tous les frais de transport liés à ce processus de garantie. Exceptions Cette garantie ne s’applique pas dans les situations suivantes : a) Si le produit a été utilisé pour une fin autre que celle indiquée dans le guide de l’utilisateur final ou le manuel d’instructions. b) Si les conditions d’utilisations ne sont pas habituelles. c) Si le produit a été modifié ou réparé par une personne non autorisée par TECHTRONIC INDUSTRIES. Remarque : Si le cordon électrique est endommagé, il doit être remplacé par un centre de réparations agréé pour éviter les risques d’électrocution. SEGURIDAD ELÉCTRICA •No recoja material húmedo. No use agua para que no se levante el polvo. •No maneje la batería ni la aspiradora con las manos húmedas. •Almacénese en interiores. No se exponga a la lluvia. SEGURIDAD PERSONAL •MANTÉNGASE ALERTA. Preste atención a lo que está haciendo y use el sentido común. No use la aspiradora mientras está cansado, distraído o bajo la influencia de drogas, alcohol o medicamentos que ocasionen disminución del control. 13 •La operación de una aspiradora puede ocasionar que objetos extraños sean lanzados hacia los ojos, lo que puede causar daño ocular. Siempre use lentes o gafas de seguridad con protectores laterales al usar la aspiradora. •Utilice una mascarilla facial o use una solución de extracción de polvo que cumpla con las normas de OSHA cuando trabaje en condiciones de mucho polvo. Las partículas de polvo pueden dañar sus pulmones. •Evite el arranque accidental. Asegúrese de que el interruptor esté en posición de apagado antes de insertar la batería. Insertar la batería en una aspiradora con el interruptor en posición de encendido es invitar a que ocurra un accidente. •No estire el cuerpo demasiado. Mantenga un buen contacto entre los pies y el suelo y mantenga el equilibrio en todo momento. Esto permite un mejor control de la aspiradora en situaciones inesperadas. •Nunca se pare en la aspiradora ni la use como escalón. •Mantenga el cabello, ropa holgada, dedos y todas las partes del cuerpo lejos de las aberturas y partes móviles. •Utilice únicamente como se describe en este manual. Utilice únicamente los accesorios recomendados por el fabricante. • Dé mantenimiento a la aspiradora. Verifique que no haya desalineación, amarre de partes móviles, partes rotas o alguna otra condición que pueda afectar el funcionamiento de la aspiradora. Si se daña, asegúrese de que la aspiradora sea reparada antes de utilizarse. Muchos accidentes son ocasionados por herramientas con mantenimiento deficiente. •Válgase siempre de su sentido común y sea cuidadoso cuando utilice herramientas. No es posible anticipar todas las situaciones que podrían tener un desenlace peligroso. No utilice esta herramienta si no entiende estas instrucciones de uso o si considera que el trabajo a realizar supera sus capacidades, comuníquese con Milwaukee Tool o con un profesional capacitado para recibir capacitación o información adicional. •Conserve las etiquetas y las placas nominales. Contienen información importante. Si son ilegibles o no están presentes, comuníquese con un centro de servicio MILWAUKEE para obtener un reemplazo gratuito. •Este producto es adecuado para la recolección de polvo de sílice cuando se utiliza de acuerdo con estas instrucciones. Para reducir el riesgo de peligros en la salud por inhalación de otros vapores o polvo, no aspire materiales tóxicos, cancerígenos ni otras sustancias peligrosas, como por ejemplo asbestos, arsénico, bario, berilio, plomo, pesticidas u otras sustancias que pongan en riesgo su salud. • Algunos polvos generados por el lijado eléctrico, aserrado, pulido, taladrado y otras actividades de construcción contienen químicos identificados como causantes de cáncer, defectos congénitos u otros daños reproductivos. Algunos ejemplos de estos químicos son: •plomo de pintura basada en plomo •dióxido de silicio de los ladrillos y el cemento y otros productos de albañilería y •arsénico y cromo de madera con tratamiento químico. Su riesgo por estas exposiciones varía, dependiendo de la frecuencia con que realice este tipo de trabajo. Para reducir su exposición a estos químicos: trabaje en un área bien ventilada y trabaje con equipo de seguridad aprobado, como mascarillas protectoras contra polvo especialmente diseñadas para filtrar partículas microscópicas. • La unidad cumple como una solución de datos objetivos de la norma OSHA 29CRF 1926.1153 cuando se usa sin el recolector de polvo, suponiendo que se usa de conformidad con las instrucciones de MILWAUKEE. Para más detalles sobre los métodos de cumplimiento, haga referencia a https://www.osha.gov. Visite https://www.milwaukeetool.com para obtener una ficha técnica objetiva. USO Y CUIDADO •Sólo utilice el producto de la forma descrita en este manual. Use solamente accesorios recomendados por el fabricante. •No se utilice para levantar líquidos inflamables o combustibles como gasolina, ni se utilice en áreas donde puedan estar presentes. •No levante nada que se esté quemando o emitiendo humo, como cigarrillos, cerillos o cenizas calientes. •No levante hollín, cemento, yeso o polvo de tablarroca si el filtro no está colocado. Estas son partículas muy finas que pueden afectar el desempeño del motor o regresarse al ambiente. •Para reducir el riesgo, no la utilice para aspirar materiales peligrosos, tóxicos o carcinógenos, como asbesto o pesticidas. •Tenga especial cuidado al descargar tanques muy cargados. •Para evitar la combustión espontánea, vacíe el recolector de polvo después de cada uso. •No deje la aspiradora sin supervisión cuando tenga instalada la batería. Retire la batería cuando no lo use y antes de realizarle un servicio. •No coloque ningún objeto en las aberturas. No use con ninguna de las aberturas bloqueadas; manténgalas libres de polvo, pelusa, cabello o cualquier otro objeto que pudiera reducir el flujo de aire. •Es posible que haya choques por estática en áreas secas o cuando la humedad relativa del aire es baja. Esta es una situación temporal y no USO Y CUIDADO DE LAS afecta el uso de la aspiradora. Para disminuir la freHERRAMIENTAS CON BATERÍA cuencia de choques por estática, agregue humedad •Utilice la aspiradora únicamente con baterías al aire con un humidificador de consola o instalado. específicamente diseñadas. El uso de cualquier •Algunas maderas contienen conservadores y otra batería puede producir un riesgo de lesiones pueden ser tóxicos. Tenga mucho cuidado para e incendio. evitar la inhalación y el contacto con la piel •Apague todos los controles antes de retirar la cuando trabaje con estos materiales. Solicite y batería. siga cualquier información de seguridad disponible •Para reducir el riesgo de descarga eléctrica, no con su proveedor de material. lo utilice en superficies húmedas. No se exponga a la lluvia. Almacene en interiores. ADVERTENCIA 14 DESCRIPCION FUNCIONAL •Antes de usar la batería o el cargador, lea los manuales del operador y todas las etiquetas de la batería, el cargador y la aspiradora. •Recargue únicamente con el cargador especificado por el fabricante. Un cargador que es adecuado para un tipo de batería puede crear un riesgo de incendio si se utiliza con otra batería. •Cuando la batería no está en uso, manténgala alejada de otros objetos metálicos como sujetapapeles, monedas, llaves, clavos, tornillos u otros objetos metálicos pequeños que puedan formar una conexión de una terminal a otra. Crear un corto entre las terminales puede ocasionar quemaduras o un incendio. •No utilice una batería o aspiradora dañada. Si la batería o la aspiradora no está funcionando como debería, se ha dejado caer, está dañada, se dejó a la intemperie o cayó en agua, regrésela a un centro de servicio. 1 2 6 3 MANTENIMIENTO •Lleve su herramienta eléctrica a servicio con un técnico calificado que use únicamente piezas de reemplazo idénticas. Esto asegurará que la seguridad de la herramienta eléctrica se mantenga. •Nunca dé servicio a baterías dañadas. Únicamente el fabricante o proveedores de servicio autorizados deben dar servicio a las baterías. 5 4 7 REGLAS ESPECIFICAS DE SEGURIDAD 8 •Antes de utilizar la aspiradora, lea este manual del operador, los manuales de la batería y el cargador y todas las etiquetas de la aspiradora, la batería y el cargador. •Nunca use la aspiradora si el tanque y/o los filtros no están instalados correctamente. La aspiradora aventará polvo y basura al aire. •Nunca limpie el filtro con agua. Limpie con pequeños golpecitos o limpie el polvo con aire comprimido. El agua provocará que falle el filtro. •Utilice protectores auditivos. La exposición al ruido puede causar pérdida auditiva. 12 9 10 LEA Y CONSERVE TODAS LAS INSTRUCCIONES PARA CONSULTARLAS EN EL FUTURO 11 13 15 14 1. 2. 3. 4. 5. 6. 16 Asa para traslado Botón del asa del tanque Tanque Base de la batería Broche de la manguera Válvula de entrada de la aspiradora 7. Soporte del tubo de extensión 8. Correas superiores de la mochila 9. Placa de la mochila 15 17 10. Correas inferiores de la mochila 11. Interruptor 12. Manguera flexible 13. Tubo de extensión telescópico 14. Herramienta para el piso 15. Adaptador de extracción de polvo 16. Herramienta para resquicios 17. Filtro HEPA SIMBOLOGÍA Retirar/instalar el filtro Para retirar el filtro: Tapa del 1. Extraiga la batería. tanque 2. Oprima el botón del asa del Volts tanque y retire el tanque de la Filtro aspiradora. 3. Jale la tapa del tanque para Corriente continua exponer el filtro. Retire el filtro del tanque. Lea el manual del operador 4. Levante el botón de liberación del tanque y vacíe todo el polvo Tanque y basura del tanque. Siempre use protección para los ojos. 5. Para limpiar el filtro, dé pequeños golpecitos o limpie el polvo con aire comprimido. ReemUS UL Listing Mark para C place el filtro si está dañado o Canadá y Estados Unidos disminuye la succión (paquete Botón de liberación del tanque único, Cat. No. 49-90-1963). NOTA: Nunca limpie el filtro con agua. Para instalar el filtro: Cat. No....................................................... 0885-20 1. Coloque el filtro en la parte superior del tanque. Volts.............................................................. 18 CD 2. Alinee las guías de la tapa del tanque y fíjela al Tipo de batería..............................................M18™ tanque. Vuelva a colocar el tanque en la aspiraTipo de cargador...........................................M18™ dora. Volumen de aire.......................55 pi3/min (55 CFM) Utilice únicaSucción sellada................................ 193,0 cm (76") mente accesoPotencia de aire...................................... 159 vatios rios específicamente recomendados para esta Capacidades.......................................3,8 L (1 Gal.) herramienta. Puede ser peligroso utilizar otros. Temperatura ambiente recomendada para operar............... -18°C to 50°C (0°F to 125°F) Instalación/remoción de los accesorios Tubo de extensión telescópico.............. 14-37-0005 Para instalar la manguera, empuje el accesorio en Manguera flexible.................................. 31-01-0305 la entrada de la aspiradora. Para instalar las boHerramienta para resquicios................. 31-01-0310 quillas y extensiones, empuje el accesorio en el Herramienta para el piso....................... 31-01-0315 extremo de la manguera. Adaptador de extracción de polvo......... 31-01-0320 Para retirar, oprima el broche del accesorio y jale. Filtro HEPA............................................ 49-90-1963 Guardar los accesorios Manguera complementaria Herramienta de 2,7 m (9').......................................... 49-90-1964 Cada accesorio puede guardpara el piso arse in la aspiradora. • Tu b o d e e x t e n s i ó n telescópico: Abroche el accesorio en el soporte del Para reducir el tubo de extensión. r i e s g o d e • Herramienta para el piso: lesión, siempre retire las baterías antes de retirar Inserte el accesorio en la Tubo de extensión el tanque. parte superior del tubo de telescópico Mantenga el filtro extensión telescópico. limpio. La eficacia de la aspiradora depende mucho del filtro. Un filtro sucio reducirá el flujo de aire y la eficacia general del sistema. No limpie con agua. Retire del tanque y • Manguera flexible: Inserte el dé golpecitos o use aire comprimido para limpi- accesorio en la entrada de arlo. la aspiradora. Abroche en el broche de la manguera para Retirar/insertar la batería Para extraer la batería, presione los botones de liber- fijarla. ación y jale la batería para sacarla de la herramienta. Siempre retire la batería antes de cambiar o retirar los accesorios. Para insertar la batería, deslícela dentro del cuerpo de la herramienta. Asegúrese de que se fije firmeManguera mente en su lugar. flexible ESPECIFICACIONES ADVERTENCIA Montar la aspiradora • Herramienta para resquicios: Enganche el accesorio en los travesaños de la herramienta para resquicios ubicado en la correa inferior de la mochila. Empuje la punta del accesorio por el travesaño inferior y amarre con la correa a la parte superior al travesaño superior. • Adaptador de extracción de polvo: Enganche el accesorio en el travesaño del adaptador de extracción de polvo ubicado en la correa inferior de la mochila. La aspiradora puede colgarse y montarse a una superficie para facilidad de uso. Para montar la aspiradora, retire la placa de la mochila de conformidad con las instrucciones de cómo "Retirar o instalar la placa de la mochila”. Esto expondrá el gancho para montar. Jale el gancho alejado de la aspiradora, desabroche las correas del gancho y enganche la aspiradora en la superficie. Fije abrochando las correas del gancho y apretando en la superficie. Adaptador de extracción de polvo Gancho para montar Herramienta para resquicios Retirar o instalar la placa de la mochila Correas del gancho La placa de la mochila puede retirarse cuando se monta la aspiradora en una superficie o se carga a mano. Para retirar la placa, oprima y sostenga el botón de liberación de la placa de la mochila. Jale el extremo inferior de la placa alejado de la aspiradora para retirar las pestañas inferiores. Jale la placa hacia abajo y alejada de la aspiradora para retirar las pestañas superiores. Para desmontar la aspiradora, desenganche las correas del gancho. Jale el gancho de la superficie y empuje el gancho hacia atrás en la aspiradora. Vuelva a instalar la placa de la mochila de conformidad con las instrucciones de cómo "Retirar o instalar la placa de la mochila”. OPERACION ADVERTENCIA Para reducir el riesgo de incendio y lesiones, no use la herramienta para aspirar materiales inflamables ni combustibles. Para reducir el riesgo de lesiones, utilice gafas o lentes de seguridad con protectores laterales. Vacíe el tanque antes de usarlo. Antes de usar, asegúrese de que el filtro esté instalado. No cargue la aspiradora por el asa del tanque. ENSAMBLAJE ADVERTENCIA PRECAUCIÓN Botón de liberación de la placa de la mochila Para instalar la placa, alinee e inserte las pestañas superiores de la placa en la aspiradora. Levante la placa para alinear e insertar las pestañas inferiores de la placa dentro de la aspiradora. Empuje las pestañas hacia adentro para bloquear. ADVERTENCIA Cómo arrancar, detener y controlar la velocidad Oprima el interruptor de Encendido en el 2 para operar la aspiradora en potencia Alta. Oprima el interruptor de Encendido en el 1 para operar la aspiradora en potencia Baja. Para apagar la aspiradora, regrese el interruptor de encendido a su posición inicial. ADVERTENCIA 16 17 reducir el ADVERTENCIA Para riesgo de lesio- Usar la aspiradora Hay muchas maneras de usar la aspiradora que mejor se adaptará a su trabajo. • Usar la aspiradora como mochila. Coloque la aspiradora en su cuerpo. Fije la herramienta amarrándola en la parte superior en inferior con las correas de la mochila. • Montar la aspiradora en la superficie. Retire la placa de la mochila de conformidad con las instrucciones de cómo "Retirar o instalar la placa de la mochila”. Después, monte la aspiradora a la superficie de conformidad con las instrucciones de “Montar la aspiradora”. • Cargar la aspiradora con la mano. Si lo desea, retire la placa de la mochila de conformidad con las instrucciones de cómo "Retirar o instalar la placa de la mochila”. nes, descarga eléctrica o daño a la herramienta, nunca la sumerja en líquidos ni permita que estos fluyan dentro de la misma. Limpieza Limpie el polvo y suciedad de las ventilas. Mantenga los mangos limpios, secos y libres de aceite o grasa. Use solo jabón neutro y un trapo húmedo para limpiar, ya que algunos substancias y solventes limpiadores son dañinos a los plásticos y partes aislantes. Algunos de estos incluyen: gasolina, turpentina,thíner, lacas, thíner para pinturas, solventes para limpieza con cloro, amoníaco y detergentes caseros que tengan amonia. Nunca usa solventes inflamables o combustibles cerca de una herramienta. Reparaciones Operación 1. Retire TODA la mugre y basura que encuentre en el tanque. 2. Inserte la batería y fije los accesorios. 3. Oprima el interruptor de Encendido a la velocidad deseada. Inicie el aspirado. 4. Apague la aspiradora inmediatamente después de terminar un trabajo o cuando el tanque esté lleno y listo para vaciarse. NOTA: Si se apaga la succión, apague la aspiradora inmediatamente y vacíe el tanque. 5. Quite la batería. 6. Limpie frecuentemente el interior del tanque y los accesorios. Si su herramienta, batería o cargador están dañados, envíela al centro de servicio más cercano. Almacepnamiento CENTRO DE ATENCION A CLIENTES Techtronic Industries Mexico, S.A. de C.V. Av. Presidente Masarik 29 Piso 7 11560 Polanco V Seccion Miguel Hidalgo, Distrito Federal, México 01 (800) 030-7777 o (55) 4160-3540 Lunes a Viernes (9am a 6pm) O contáctanos en www.milwaukeetool.com.mx ACCESORIOS ADVERTENCIA Utilice sólo los accesorios específicamente recomendados. Otros accesorios puede ser peligroso. Para una lista completa de accessorios, visite nuestro sitio en Internet: www.milwaukeetool.com o póngase en contacto con un distribuidor. SOPORTE DE SERVICIO - MEXICO Antes de guardar la aspiradora, vacíe y limpie el tanque, el filtro y los accesorios. Retire la batería. MANTENIMIENTO ADVERTENCIA Para reducir el riesgo de una lesión, desconecte siempre la herramienta antes de darle cualquier mantenimiento. Nunca desarme la herramienta ni trate de hacer modificaciones en el sistema eléctrico de la misma. Acuda siempre a un Centro de Servicio MILWAUKEE para TODAS las reparaciones. GARANTÍA LIMITADA - E.U.A. Y CANADÁ **El periodo de garantía para los radios para obra, puerto de energía M12™, fuente de poder M18™, ventiladores para obra y carretillas de trabajo industrial Trade Titan™ es de un (1) año a partir de la fecha de compra. El periodo de garantía para los Cables de limpieza de drenaje es de dos (2) años a partir de la fecha de compra. El periodo de garantía de la Pistola de calor compacta M18™ de la Extractor de polvo de 8 galones es de tres (3) años a partir de la fecha de compra. El periodo de garantía de las lámparas de LED en la Lámpara de trabajo LED y el Bulbo mejorado de LED para la Luz de trabajo es por la vida del producto sujeto a las limitaciones anteriores. Si durante el uso normal el LED o Bulbo de LED falla, la parte será reemplazada sin cargo. No se requiere el registro de la garantía para obtener la garantía correspondiente a un producto de herramienta eléctrica de MILWAUKEE. La fecha de manufactura del producto se utilizará para determinar el periodo de garantía si no se proporciona comprobante de compra al solicitar el servicio en garantía. LA ACEPTACIÓN DE LOS REMEDIOS EXCLUSIVOS DE REPARACIÓN Y REEMPLAZO AQUÍ DESCRITOS ES UNA CONDICIÓN DEL CONTRATO PARA LA COMPRA DE TODO PRODUCTO DE MILWAUKEE. SI USTED NO ACEPTA ESTA CONDICIÓN, NO DEBE COMPRAR EL PRODUCTO. MILWAUKEE NO SERÁ RESPONSABLE EN NINGÚN CASO DE DAÑOS INCIDENTALES, ESPECIALES, EMERGENTES O PUNITIVOS NI DE NINGÚN COSTO, HONORARIOS LEGALES, GASTOS, PÉRDIDAS O DEMORAS ALEGADOS COMO CONSECUENCIA DE ALGÚN DAÑO, FALLA O DEFECTO EN NINGÚN PRODUCTO, INCLUYENDO, ENTRE OTROS, RECLAMACIONES POR PÉRDIDA DE UTILIDADES. ALGUNOS ESTADOS NO PERMITEN LA EXCLUSIÓN O LIMITACIÓN DE RESPONSABILIDAD POR DAÑOS INCIDENTALES O EMERGENTES, POR LO QUE LA ANTERIOR LIMITACIÓN O EXCLUSIÓN PODRÍA NO APLICARSE EN SU CASO. ESTA GARANTÍA ES EXCLUSIVA Y REEMPLAZA TODAS LAS DEMÁS GARANTÍAS EXPRESAS, ESCRITAS U ORALES. EN LA MEDIDA EN QUE LO PERMITA LA LEY, MILWAUKEE DESCONOCE CUALQUIER GARANTÍA IMPLÍCITA, INCLUYENDO SIN LIMITACIÓN CUALQUIER GARANTÍA IMPLÍCITA DE COMERCIABILIDAD O IDONEIDAD PARA UN FIN O USO ESPECÍFICO; EN LA MEDIDA EN QUE DICHO DESCONOCIMIENTO NO SEA PERMITIDO POR LA LEY, DICHAS GARANTÍAS IMPLÍCITAS SE LIMITAN A LA DURACIÓN DE LA GARANTÍA EXPRESA CORRESPONDIENTE SEGÚN SE DESCRIBIÓ ANTERIORMENTE. ALGUNOS ESTADOS NO PERMITEN LIMITACIONES SOBRE LA DURACIÓN DE UNA GARANTÍA IMPLÍCITA, POR LO QUE LA ANTERIOR LIMITACIÓN PUDIERA NO APLICARSE A USTED. ESTA GARANTÍA LE DA DERECHOS LEGALES ESPECÍFICOS Y USTED PODRÍA ADEMÁS TENER OTROS DERECHOS QUE VARÍAN DE UN ESTADO A OTRO. Esta garantía aplica al producto vendido en los Estados Unidos y Canadá únicamente. Consulte la “Búsqueda de centro de servicio” en la sección de Partes y servicio del sitio web de MILWAUKEE en www.milwaukeetool.com o llame al 1.800.SAWDUST (1.800.729.3878) para localizar su centro de servicio más cercano para darle servicio con y sin garantía a una herramienta eléctrica de Milwaukee. Cada herramienta eléctrica* de MILWAUKEE (ver excepciones a continuación) está garantizada para el comprador original únicamente de que no tenga material y mano de obra defectuosos. Sujeto a ciertas excepciones, MILWAUKEE reparará o reemplazará cualquier parte en una herramienta eléctrica que tenga defectos de material o mano de obra según lo determine MILWAUKEE mediante una revisión, por un periodo de cinco (5) años** después de la fecha de compra a menos que se indique lo contrario. Al devolver la herramienta eléctrica a un Centro de Servicio de la fábrica de MILWAUKEE o a una Estación de Servicio Autorizada de MILWAUKEE, se requiere que el flete esté pagado por adelantado y asegurado. Se debe incluir una copia del comprobante de compra con el producto devuelto. Esta garantía no aplica a daños que MILWAUKEE determine que son ocasionados por reparaciones o intentos de reparaciones realizados por una persona que no sea personal autorizado de MILWAUKEE, uso indebido, alteraciones, maltrato, desgaste normal, falta de mantenimiento o accidentes. Desgaste normal: Muchas herramientas eléctricas necesitan un reemplazo periódico de partes y servicio para lograr el mejor desempeño. Esta garantía no cubre la reparación cuando el uso normal ha agotado la vida de una parte, incluyendo sin limitar a mandriles, cepillos, cables, zapatas de la sierra, abrazaderas de la hoja, anillos en O, sellos, protectores, hojas de desatornilladores, pistones, herrajes, levantadores y arandelas de cubierta de los protectores. *Esta garantía no cubre clavadoras y grapadoras neumáticas, pistola de pintura a presión, baterías inalámbricas, generadores de energía portátil de gasolina, herramientas de mano, palanca y cadena de mano de polipasto - eléctricas, indumentaria calefactada M12™, producto reacondicionado y productos de prueba y medición. Existen garantías por separado y distintas disponibles para estos productos. Mantenimiento de las herramientas Adopte un programa regular de mantenimiento y mantenga su herramienta en buenas condiciones. Inspeccione la herramienta para problemas como ruidos indebidos, desalineadas o agarrotadas de partes móviles, piezas rotas o cualquier otra condición que pueda afectar el funcionamiento de la herramienta. Envíe su herramienta al Centro de Servicio MILWAUKEE para reparación. Después de 6 meses a un año, dependiendo del uso dado, envíe su herramienta al Centro de Servicio MILWAUKEE más cercano para la inspección. Si la herramienta no arranca u opera a toda su potencia con una batería completamente cargada, limpie, con una goma o borrador, los contactos de la batería y de la herramienta. Si aun asi la herramienta no trabaja correctamente, regrésela, con el cargador y la batería, a un centro de servicio MILWAUKEE. 18 19 PÓLIZA DE GARANTÍA - VALIDA SOLO PARA MÉXICO, AMÉRICA CENTRAL Y EL CARIBE La garantía de TECHTRONIC INDUSTRIES es por 5 años a partir de la fecha original de compra. Esta tarjeta de garantía cubre cualquier defecto de material y mano de obra en ese Producto. Para hacer válida esta garantía, presente esta tarjeta de garantía, cerrada/sellada por el distribuidor o la tienda donde compró el producto, al Centro de Servicio Autorizado (ASC). O, si esta tarjeta no se ha cerrado/sellado, presente la prueba original de compra a ASC. Llame gratis al 01 (800) 030-7777 para encontrar el ASC más cercano, para servicio, partes, accesorios o componentes. Procedimiento para hacer válida esta garantía Lleve el producto a ASC, junto con la tarjeta de garantía cerrada/ sellada por el distribuidor o la tienda donde compró el producto, y cualquier pieza o componente defectuoso se reemplazará sin costo para usted. Cubriremos todos los costos de flete con relación a este proceso de garantía Excepciones Esta garantía no tendrá validez en las siguientes situaciones: a) Cuando el producto se use de manera distinta a la que indica el manual del usuario final o de instrucciones. b) Cuando las condiciones de uso no sean normales. c) Cuando otras personas no autorizadas por TECHTRONIC INDUSTRIES modifiquen o reparen el producto. Nota: si el juego de cables está dañado, tiene que reemplazarse en un Centro de Servicio Autorizado para evitar riesgos eléctricos. CENTRO DE SERVICIO Y ATENCIÓN Llame al 01 (800) 030-7777 IMPORTADO Y COMERCIALIZADO POR TECHTRONIC INDUSTRIES, MÉXICO, SA DE CV Av. President Masarik #29 piso 7, Col. Polanco V Sección CP 11560, Deleg. Miguel Hidalgo, CDMX Modelo: Fecha de Compra: Sello del Distribuidor: MILWAUKEE TOOL 13135 West Lisbon Road Brookfield, WI 53005 USA 58140126d1 08/18 01607300102Q-01(A) Printed in China
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Milwaukee M18 FUEl 0885-20 Manual de usuario

Tipo
Manual de usuario