ICY BOX IB-121CL-U3 Especificación

Categoría
Estaciones de acoplamiento HDD / SSD
Tipo
Especificación
http://www.icybox.de
2
IB-121CL-U3
http://www.icybox.de
2 3
Manual IB-121CL-U3 .............................................................................4-5
Handbuch IB-121CL-U3 .........................................................................6-7
Manuel IB-121CL-U3 .............................................................................8-9
Manual IB-121CL-U3 .........................................................................10-11
Manuale IB-121CL-U3 ........................................................................12-13
Instruções IB-121CL-U3 ....................................................................14-15
Instrukcja IB-121CL-U3.....................................................................16-17
Εγχειρίδιο IB-121CL-U3 .....................................................................18-19
Руководство IB-121CL-U3.................................................................20-21
Návod k použití IB-121CL-U3 .............................................................22-23
10
IB-121CL-U3
http://www.icybox.de
10
1. Modelo – Disco duro – Interfaz – Color
2. Contenido del embalaje
Adaptador IB-121CL-U3, fuente de alimentación, cable USB, manual
3. Características
Función de acoplamiento de dos módulos: el ordenador detecta dos unidades de disco
independientes
Función de clonación HDD sin PC: crea una copia idéntica de la unidad de disco
Crea una copia de arranque de las unidades de disco del sistema sin software ni conocimientos
profesionales
Caja de aluminio
Soporta discos duros de 2,5" y 3,5", capacidad ilimitada
Admite HDD externos Seagate GoFlex de 2,5"
USB 3.0 Host hasta 5 Gbit/s
Indicación para corriente y acceso al disco duro con LED
Pantalla LED para indicación de progreso de clonación HDD
Capacidad de disco duro sin límite
Soporta USB 2.0: PC & Mac (Windows 98/ME/2000/XP/Vista/7/8, OS> 9.1)
Soporta USB 3.0: Windows XP/Vista/7/8, OS X >10.8
Plug & Play y Hot Swap
4. Aplicación
4.1 Driver Software
4.1.1 Interfáz USB 2.0
Win 2000/XP/Vista/7/8 (and Mac OS>9.1) tienen integrados los driver para el interfáz USB 2.0.
En cuando el adaptador es conectado el sistema operativo actualiza los drivers y conecta al adaptador
automáticamente. Si utiliza un sistema operativo viejo (por ejemplo Win 98) necesita instalar los driver
USB 2.0. Porfavor consulte www.icybox.de.
4.1.2 Interfáz USB 3.0
Para utilizar el interfáz USB 3.0 es necesario tener un controlador USB 3.0 instalado en el sistema.
Modelo Disco duro Interfaz Color
IB-121CL-U3 2,5", 3,5" SATA, Seagate GoFlex 2,5" USB 3.0 plata + negro
http://www.icybox.de
1110
IB-121CL-U3
http://www.icybox.de
1110
4.2 Poner en marcha
Necesita la fuente de energía para tener suciente corriente para el disco duro.
Puede conectar IB-120CL-U3 a USB 2.0 y USB 3.0 interfaz con cable USB 3.0.
4.3 Instalación del disco duro
Un disco duro nuevo debe ser inicializado, particionado y formateado para ser visible en el sistema
operativo.
4.4 Función de acoplamiento de dos módulos
El IB-121CL-U3 le permite usar dos HDD distintos a través de una única conexión USB independiente-
mente de su marca, modelo o capacidad. Basta con conectar el IB-121CL-U3 al ordenador y los HDD se
detectarán como unidades de disco independientes. Gracias a la conexión en caliente, es posible inter-
cambiar los HDD con el sistema en ejecución.
4.5 Función de clonación HDD
- Antes de iniciar el proceso de clonación, desconecte el cable USB del dispositivo.
- Introduzca la unidad de origen en la ranura HDD1 (origen) y la unidad de destino en la ranura
HDD2 (destino).
- Pulse el botón de conexión para conectar el dispositivo. El LED de alimentación se iluminará en
color azul en el modo PC.
- Pulse y mantenga pulsado durante tres segundos el botón MODE para cambiar el modo de clonación.
El LED de alimentación cambiará la luz de color azul a rojo.
- Pulse el botón de inicio. Tanto el LED del HDD1 como el del HDD2 comenzarán a parpadear.
El primer LED del indicador de progreso (25%) también comenzará a parpadear. La clonación
está en marcha.
- Cuando el indicador de estado llegue al 100% y deje de parpadear, habrá nalizado el proceso
de clonación. Pulse el botón de conexión para desconectar el equipo y retirar los HDD.
4.6 Recomendaciones para la función de clonación
Como en el proceso de clonación se copia absolutamente todo el contenido del HDD de origen,
el proceso puede tardar horas en completarse dependiendo de la capacidad del HDD.
- Una vez nalizado el proceso de clonación, es posible que, en algunos casos, el ordenador no sea
capaz de reconocer ambas unidades de disco ya que se ha asignado a ambas la misma letra de
unidad. Para distinguir las unidades deberá asignar una nueva letra de unidad a una de las unidades
de disco en “Administración de discos” (Windows).
- Si solo se ha conectado una unidad a HDD1 (origen), no ocurrirá nada al pulsar el botón de inicio.
- El HDD de destino (HDD2) debe tener el mismo tamaño, o mayor, que el HDD de origen (HDD1).
- Si la unidad de destino (HDD2) tiene un tamaño inferior a la unidad de origen (HDD1), los LED del
HDD1 y del HDD2 comenzarán a parpadear a alta frecuencia tras pulsar el botón de inicio.
Pulse el botón de conexión para desconectar el equipo y retirar los HDD.

Transcripción de documentos

http://www.icybox.de IB-121CL-U3 Manual IB-121CL-U3..............................................................................4-5 Handbuch IB-121CL-U3..........................................................................6-7 Manuel IB-121CL-U3..............................................................................8-9 Manual IB-121CL-U3..........................................................................10-11 Manuale IB-121CL-U3.........................................................................12-13 Instruções IB-121CL-U3..................................................................... 14-15 Instrukcja IB-121CL-U3..................................................................... 16-17 Εγχειρίδιο IB-121CL-U3...................................................................... 18-19 Руководство IB-121CL-U3................................................................. 20-21 Návod k použití IB-121CL-U3.............................................................. 22-23 3 http://www.icybox.de IB-121CL-U3 1. Modelo – Disco duro – Interfaz – Color Modelo Disco duro Interfaz Color IB-121CL-U3 2,5", 3,5" SATA, Seagate GoFlex 2,5" USB 3.0 plata + negro 2. Contenido del embalaje Adaptador IB-121CL-U3, fuente de alimentación, cable USB, manual 3. Características • Función de acoplamiento de dos módulos: el ordenador detecta dos unidades de disco independientes • Función de clonación HDD sin PC: crea una copia idéntica de la unidad de disco • Crea una copia de arranque de las unidades de disco del sistema sin software ni conocimientos profesionales • Caja de aluminio • Soporta discos duros de 2,5" y 3,5", capacidad ilimitada • Admite HDD externos Seagate GoFlex de 2,5" • USB 3.0 Host hasta 5 Gbit/s • Indicación para corriente y acceso al disco duro con LED • Pantalla LED para indicación de progreso de clonación HDD • Capacidad de disco duro sin límite • Soporta USB 2.0: PC & Mac (Windows 98/ME/2000/XP/Vista/7/8, OS> 9.1) • Soporta USB 3.0: Windows XP/Vista/7/8, OS X >10.8 • Plug & Play y Hot Swap 4. Aplicación 4.1 Driver Software 4.1.1 Interfáz USB 2.0 Win 2000/XP/Vista/7/8 (and Mac OS>9.1) tienen integrados los driver para el interfáz USB 2.0. En cuando el adaptador es conectado el sistema operativo actualiza los drivers y conecta al adaptador automáticamente. Si utiliza un sistema operativo viejo (por ejemplo Win 98) necesita instalar los driver USB 2.0. Porfavor consulte www.icybox.de. 4.1.2 Interfáz USB 3.0 Para utilizar el interfáz USB 3.0 es necesario tener un controlador USB 3.0 instalado en el sistema. 10 http://www.icybox.de IB-121CL-U3 4.2 Poner en marcha Necesita la fuente de energía para tener suficiente corriente para el disco duro. Puede conectar IB-120CL-U3 a USB 2.0 y USB 3.0 interfaz con cable USB 3.0. 4.3 Instalación del disco duro Un disco duro nuevo debe ser inicializado, particionado y formateado para ser visible en el sistema operativo. 4.4 Función de acoplamiento de dos módulos El IB-121CL-U3 le permite usar dos HDD distintos a través de una única conexión USB independientemente de su marca, modelo o capacidad. Basta con conectar el IB-121CL-U3 al ordenador y los HDD se detectarán como unidades de disco independientes. Gracias a la conexión en caliente, es posible intercambiar los HDD con el sistema en ejecución. 4.5 Función de clonación HDD - Antes de iniciar el proceso de clonación, desconecte el cable USB del dispositivo. - Introduzca la unidad de origen en la ranura HDD1 (origen) y la unidad de destino en la ranura HDD2 (destino). - Pulse el botón de conexión para conectar el dispositivo. El LED de alimentación se iluminará en color azul en el modo PC. - Pulse y mantenga pulsado durante tres segundos el botón MODE para cambiar el modo de clonación. El LED de alimentación cambiará la luz de color azul a rojo. - Pulse el botón de inicio. Tanto el LED del HDD1 como el del HDD2 comenzarán a parpadear. El primer LED del indicador de progreso (25%) también comenzará a parpadear. La clonación está en marcha. - Cuando el indicador de estado llegue al 100% y deje de parpadear, habrá finalizado el proceso de clonación. Pulse el botón de conexión para desconectar el equipo y retirar los HDD. 4.6 Recomendaciones para la función de clonación Como en el proceso de clonación se copia absolutamente todo el contenido del HDD de origen, el proceso puede tardar horas en completarse dependiendo de la capacidad del HDD. - Una vez finalizado el proceso de clonación, es posible que, en algunos casos, el ordenador no sea capaz de reconocer ambas unidades de disco ya que se ha asignado a ambas la misma letra de unidad. Para distinguir las unidades deberá asignar una nueva letra de unidad a una de las unidades de disco en “Administración de discos” (Windows). - Si solo se ha conectado una unidad a HDD1 (origen), no ocurrirá nada al pulsar el botón de inicio. - El HDD de destino (HDD2) debe tener el mismo tamaño, o mayor, que el HDD de origen (HDD1). - Si la unidad de destino (HDD2) tiene un tamaño inferior a la unidad de origen (HDD1), los LED del HDD1 y del HDD2 comenzarán a parpadear a alta frecuencia tras pulsar el botón de inicio. Pulse el botón de conexión para desconectar el equipo y retirar los HDD. 11
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

ICY BOX IB-121CL-U3 Especificación

Categoría
Estaciones de acoplamiento HDD / SSD
Tipo
Especificación