Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
INSTALLATION INSTRUCTION
408 – LED Wall Sconce
WS-40832, WS-40832F
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out
or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les règlements
locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté et
ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire.
MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e instalación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de alimentación principal
en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación ETL/CETL esta lámpara.
PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
Wire Connector
Qty: 3pcs+1 Extra
7EAC112201
A
Wood Screw
Qty: 2pcs+1 Extra
7MPF2204J2
Ф 4X22
C
Plastic Anchor
Qty: 2pcs+1 Extra
7TDD082401
D
Mounting Screw
Qty: 1 Extra
4MPF0412S3BW
5/32-32x1/2
E
Junction Box Screw
Qty: 2pcs+1 Extra
7MPF0820C1
#8-32x13/16
Nickel Plating
B
4
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
INSTALLATION INSTRUCTION
408 – LED Wall Sconce
WS-40832, WS-40832F
FIG.1
PREPARATION
1. Shut o the power at the circuit breaker and remove
existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the
parts on a clear area. Be careful not to lose any small parts
necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (E) from the mounting back
plate.
4. Drill holes in the wall aligned with the key holes located in
the mounting back plate, insert the plastic anchors (D).
5. Secure the mounting plate to the junction box using
junction box screws (B), fasten it to the wall using wood
screws (C). The side of the mounting back plate marked
“GND” must face out.
CONNECTING THE WIRES (Fig. 2)
6. Connect the wires to junction box wires as shown in Fig.
2, making sure that all wire connectors (A) are secured. If
your outlet box has a green or bare copper ground wire,
connect the xture’s ground wire to it. Otherwise, connect
the xture’s ground wire directly to the back plate using the
green screw provided. After wires are connected, tuck them
carefully inside the junction box.
COMPLETING THE INSTALLATION (Fig. 1)
7. Secure the xture to the mounting back plate using the
mounting screw (E).
Junction Box Screw
Junction Box
Wire Connector
Plastic Anchor
Mounting Plate
Wood Screw
Mounting Screw
Lamp Boby
WS-40832
MOUNTING BACK PLATE
3 7/8"1 3/8"
1 3/4"
17 3/8"
23 5/8"
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring