Owens Corning WTAU Guía de instalación

Tipo
Guía de instalación

Este manual también es adecuado para

Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
WOODCREST
& WOODMOOR
SHINGLES INSTALLATION INSTRUCTIONS
INSTRUCCIONES PARA LA INSTALACION DE TEJAS WOODCREST
Y WOODMOOR
45575_OC_instructions.indd 145575_OC_instructions.indd 1 11/8/06 1:52:36 PM11/8/06 1:52:36 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
45575_OC_instructions.indd 245575_OC_instructions.indd 2 11/8/06 1:52:40 PM11/8/06 1:52:40 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
Application Instructions:
Before installing this product, check local building codes for their
roofing requirements.
These laminated shingles are designed for new or reroofing work over
any properly built and supported wood roof deck having adequate
nail holding capacity and a smooth surface. Check local building codes
regarding deck load limits. Because Owens Corning Woodcrest
/
Woodmoor
shingles are 360/465 avg. wt./sq., it must be determined if
the roof frame can support workers and the weight of the shingles. It
may not be feasible to apply the product over an existing shingle roof.
Precautionary Note:
The manufacturer will not be responsible for problems resulting from
any deviation from the recommended application instructions and the
following precautions:
Roof Top Loading: Lay shingle bundles flat. Do not bend over the ridge.
Roof Deck:
6" Maximum roof deck boards
• Minimum
3
8" plywood
• Minimum
7
16" OSB
Regardless of deck type used, the roofing installer must:
1. Install the deck material in strict compliance with the deck
manufacturer’s instructions.
2. Prevent the deck from getting wet before, during and after installation.
Ventilation: Must meet or exceed FHA Minimum Property Standards.
Handling: Use extra care in handling shingles when the temperature is
below 40°F.
Storage: Store in a covered ventilated area at a maximum temperature of
110°F. Stack in a flat fashion (maximum of 10 bundles high). Protect shingles
from weather when stored at the job site. Do not store near steam pipes,
radiators, etc.
Nails must be corrosion-resistant, 11- or
12-gauge, with heads at least
3
8" in diameter.
Staples must be 16-gauge minimum,
15
16"
minimum crown width and sufficient length
to penetrate
3
4" into wood decking or through
APA-rated roof sheathing. Staples are to be
corrosion protected.
All Fasteners must penetrate at least
3
4"
into the wood deck or completely through
plywood sheathing.
Notice: Owens Corning recommends the use
of nails as the preferred method of attaching shingles
to wood decking or other nailable surface.
Instrucciones para la aplicación:
Antes de instalar este producto, consulte los códigos de construcción
locales para informarse sobre los requisitos de techado.
Estas tejas laminadas fueron diseñadas para techar por primera vez
o retechar cualquier entablonado de techo de madera apoyado y
correctamente construido, siempre que tenga capacidad de retención
de clavos y una superficie lisa. Consulte los códigos de construcción
locales sobre los límites de carga del entablonado. Debido a que las
tejas Woodcrest
/Woodmoor
de Owens Corning pesan en promedio
360/465 libras pies/2, es necesario determinar si la estructura del techo
puede sostener a los trabajadores y el peso de las tejas. Quizás no sea
posible aplicar el producto sobre un techo de tejas existentes.
Nota de precaución:
El fabricante no será responsable de problemas que sean consecuencia
de no seguir exactamente las instrucciones de aplicación recomendadas
y las siguientes precauciones:
Carga sobre techo: Coloque los grupos de tejas de manera plana sobre
el techo. No los doble sobre la cumbrera.
Entablonado de techo:
6 pulg. como máximo para tablas de entablonado
3
8 pulg. como mínimo para madera terciada
7
16 pulg. como mínimo para paneles de fibra orientada
Cualquiera que sea el tipo de entablonado utilizado, el instalador debe:
1. Instalar el material del entablonado siguiendo estrictamente las
instrucciones del fabricante del entablonado.
2. Evitar que el entablonado se moje antes, durante y después de
la instalación.
Ventilación: Debe cumplir o exceder las normas mínimas para propiedades
establecidas por el FHA.
Manipulación: Tenga mucho cuidado al manipular las tejas cuando la tem-
peratura sea inferior a 40°F.
Almacene: En un área cubierta y ventilada a una
temperatura no mayor de 110°F/43°C. Apilar
de manera plana (grupos con un máximo de
10 tejas). Proteja las tejas del clima cuando las
almacene en el lugar de trabajo. No almacene
cerca de tuberías de vapor, radiadores, etc.
Los clavos deben ser inoxidables, de calibre 11
ó 12, con cabezas de por lo menos
3
8 pulg. de
diámetro. Las grapas deben ser, como mínimo,
de calibre 16 con un ancho de corona de al
menos
15
16 pulg. y una longitud suficiente para penetrar
3
4 pulg. en el ent-
ablonado de madera o a través de un revestimiento de techo que cum-
pla con las normas APA. Las grapas deben ser a prueba de corrosión.
Todos los fijadores deben penetrar al menos
3
4 pulg. en el entablonado de
madera o completamente a través del recubrimiento de madera terciada.
Aviso: Owens Corning recomienda el uso de clavos como método
preferido para fijar tejas a entablonados de madera o a otras superficies
aptas para clavos.
1
45575_OC_instructions.indd 345575_OC_instructions.indd 3 11/8/06 1:52:40 PM11/8/06 1:52:40 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
Specialty Eave Flashing:
WeatherLock
®
underlayment or
equivalent eave and flashing membrane
applied to a point at least 24" beyond
interior wall line. See manufacturer’s
installation instructions. See Fig. 1.
Revestimiento especial
para alero:
Membrana de revestimiento y alero
WeatherLock
®
reforzamiento o similar,
aplicada en un punto al menos 24 pulg.
más allá de la línea interior de la pared.
Vea las instrucciones de instalación del
fabricante. Vea la Fig. 1.
Underlayment:
Standard Slope (4" in 12" or more):
Application of underlayment, metal drip
edges, and eaves flashing: See Fig. 2.
Low Slope (2" in 12" to less than 4" in
12"): Application of underlayment and
metal drip edges: See Fig. 2A.
Capa inferior:
Pendiente estándar (4 pulg. cada 12
pulg. o más): Aplicación de capa inferior,
bordes de goteo metálicos y revestimiento
de alero: Vea la Fig. 2.
Pendiente baja (2 pulg. cada 12 pulg.
hasta menos de 4 pulg. cada 12 pulg.):
Aplicación de capa inferior y bordes
de goteo metálicos: Vea la Fig. 2A.
22
11
2
45575_OC_instructions.indd 445575_OC_instructions.indd 4 11/8/06 1:52:40 PM11/8/06 1:52:40 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
Starter Course:
Left Rake Application: Cut 35" off from
the first bottom starter piece. Fasten
the remaining 5" x 13
3
8" to the deck
as shown in Fig. 3, followed by a full
13
3
8" x 40" starter piece to the deck
with 5 fasteners as shown.
Right Rake Application: Cut 5" off from
the first bottom starter piece. Fasten
the remaining 35" x 13
3
8" to the deck
as shown in Fig. 3, followed by a full
13
3
8" x 40" starter piece to the deck
with 5 fasteners as shown.
Caution: Using shingle products other
than WoodStart
Starter Strip for the
starter course may result in a color
variation at the lower edge of the roof.
Hilera inicial:
Aplicación de la inclinación izquierda:
Corte 35 pulg. de la parte superior de
la pieza de inicio. Sujete la parte restante
(5 pulg. x 13
3
8 pulg.) al techo como se
muestra en la Fig. 3 y luego sujete una
pieza de inicio completa (13
3
8 pulg. x 40
pulg.) al techo con 5 fijadores como
se indica.
Aplicación de la inclinación derecha:
Corte 5 pulg. de la parte superior de
la pieza de inicio. Sujete la parte restante
(35 pulg. x 13
3
8 pulg.) al techo como se
muestra en la Fig. 3 y luego sujete una
pieza de inicio completa (13
3
8 pulg. x 40
pulg.) al techo con 5 fijadores como
se indica.
Precaución: Utilizar otros productos
de tejas distintos a las hileras de inicio
WoodStart
al momento de armar
la hilera inicial puede ocasionar una
variación del color del extremo inferior
del techo.
Fi
g.
3
Hilera inicial
Starter
Course
Right Rake Application
Left Rake Application
Aplicación izquierda del inclinación
Aplicación izquierda del inclinación
Rake edge
Starter strip is flush
with drip edges
Pieza de inicio completa
a nival borde de goteo
Nail area
Nail area Área de clavos
Área de clavos
Rake edge
Borde de viga inclinada
Borde de viga inclinada
Asphalt saturated
felt underlayment
Asfalte saturado
felpa reforzamiento
40" Full Starter
Pieza de inicio de 40 pulg.5"
35"
Removed
Quitara
40" Full Starter
35"
5"
Removed
Quitara
33
Shingle Fastening:
Standard Fastening Pattern:
Place fasteners in nail area. See Fig. 4.
Fijación de tejas:
Esquema de fijación estándar:
Coloque los fijadores en el área de
clavos. Vea la Fig. 4.
Fig. 4
Esquema de fijación estándar
S
tandard Fastening Pattern
40"
14
1
/
4
"
1
/
2
"
1
/
2
"
1
1
/
2
"
1
1
/
2
"
Nails
Clavos
Offset cuts
Cortes de desplazamiento
Nail area
Área de clavos
44
3
45575_OC_instructions.indd 545575_OC_instructions.indd 5 11/8/06 1:52:40 PM11/8/06 1:52:40 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
Measurement Area:
When aligning for offset pattern,
measure from area A or area B.
See Fig. 6.
Área de medición:
Al alinear para los patrones de desplaza-
miento, mida del área A o área B.
Vea la Fig. 6.
Fig. 6
Área de medida
Measurement Area
AREA
B
AREA
A
15"
5"
15"
5"
66
Fig. 7
Aplicación de tejas en patrón de desplazamiento de 5 pulg. y 5 pulg.
Shingle Application 5"& 5" offset pattern
5"
5"
5"
5"
5"
10"
15"
20"
20"
25"
30"
35"
Full Shingle (1st Course)
Tejada completo
(primera hilera)
Tejada completo
(primera hilera)
Full shingle (1st course)
5" & 5" Course
Application:
Owens Corning Woodcrest
/
Woodmoor
shingles can be applied
with a 5" & 5" OR 5" & 15" offset,
(See Fig. 4) with 4" exposure. Shingles
can be installed from either left or
right rake edge.
First Course: Start with a full shingle
even with the lower edge of the starter
course shingle. See Fig. 7.
Colocación de hileras
de 5 pulg. y 5 pulg.:
Las tejas Woodcrest
/Woodmoor
de Owens Corning deben instalarse
con un desplazamiento de 5 pulg. y 5
pulg. Ó 5 pulg. y 15 pulg. (Vea la
Fig. 4) con un área expuesta de 4 pulg.
Las tejas se pueden instalar tanto desde
el borde de inclinación derecho
o izquierdo.
Primera hilera: Empiece con una teja
completa colocándola al ras del borde
inferior de la hilera inicial. Vea la Fig. 7.
77
Mansard or Steep Slope
Fastening Pattern:
See Fig. 5.
REQUIRED: For slopes exceeding
60 degrees or 21 inches per foot,
9 nails are required with 5 in the nail
area and 4 placed above tab cutouts.
1. Position the first course shingle
applying 5 nails in the nail area.
2. Temporarily position the second
course shingle above to determine
the location for the additional
4 fasteners.
3. Once you have added the additional
fasteners in the tab area, apply
4 spots of asphalt cement under
each tab and press in place.
4. Apply all succeeding shingle courses
in the same manner.
Note: Too much roofing cement can
cause shingles to blister.
Plastic Cement where required must
meet ASTM D 4586, Type I or II
(Asbestos Free).
Esquema de fijación para
mansardas o pendientes
agudas: Vea la Fig. 5.
PROCEDIMIENTO REQUERIDO: Para
pendientes de más de 60 grados o
21 pulgadas por cada pie, utilice nueve
clavos, coloque 5 en el área de clavos y
4 sobre de las lengüetas de las tejas.
1. Aplique la primera hilera de tejas
colocando 5 clavos en el área
de clavos.
2. Aplique encima, de forma temporal,
la segunda hilera de tejas para
determinar la ubicación de los 4
fijadores adicionales.
3. Una vez que haya añadido los
fijadores adicionales en el área de la
lengüeta, coloque 4 capas de cemento
de asfalto debajo de cada lengüeta y
presione en el sitio.
4. Coloque todas las hilera de tejas
siguientes de la misma manera.
Nota: Demasiado cemento puede oca-
sionar que se formen burbujas de aire
en las tejas.
El cemento plástico, en los casos en
que se requiera, debe cumplir con la
norma ASTM D 4586, Tipo I o II
(libre de asbestos).
2"
1"
Asphalt roofing cement
Additional 4 nails
4 clavos adicionales
Temporary second course shingles (with pattern)
to determine the location for the additional 4 fasteners
Teja temporal de segunda hilera o tendido (según patrón)
para determinar la ubicación de los 4 clavos adicionales
Cemento de techo de asfalto
Fig. 5
Esquema de fijación para mansardas o pendientes agudas
Mansard or Steep Slope Fastening Pattern
55
4
45575_OC_instructions.indd 645575_OC_instructions.indd 6 11/8/06 1:52:41 PM11/8/06 1:52:41 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
5
5" & 15" Course
Application:
Owens Corning Woodcrest
/
Woodmoor
shingles can be applied
with a 5" & 5" OR 5" & 15" offset,
(See Fig. 4) with 4" exposure. Shingles
can be installed from either left or
right rake edge.
First Course: Start with a full shingle
even with the lower edge of the starter
course shingle. See Fig. 8.
Second Course: Cut 5" from a full
shingle. Install the remaining 35" piece
using the alignment notch on the
shingle. See Fig. 8A.
Third Course: Cut 20" from a full
shingle. Install the remaining 20" piece
using the alignment notch on the
shingle. See Fig. 8B.
Fourth Course: Cut 25" from the
edge of the fourth course full shingle.
Install the remaining 15" piece using the
alignment notch on the shingle.
See Fig. 8C.
Succeeding Courses: For succeed-
ing courses, repeat first through fourth
course. See Fig. 8D.
Colocación de hileras de
5 pulg. y 15 pulg.:
Las tejas Woodcrest
/Woodmoor
de Owens Corning deben instalarse
con un desplazamiento de 5 pulg. y 5
pulg. Ó 5 pulg. y 15 pulg. (Vea la
Fig. 4) con un área expuesta de 4 pulg.
Las tejas se pueden instalar tanto desde
el borde de inclinación derecho
o izquierdo.
Primera hilera: Comience con una
teja completa colocándola al ras del
borde inferior de la teja de la hilera
inicial. Vea la Fig. 8.
Segunda hilera: Corte 5 pulg. de una
teja completa. Coloque la parte res-
tante (35 pulg.) utilizando la marca de
alineación de la teja. Vea la Fig. 8A.
Tercera hilera: Corte 20 pulg. de
una teja completa. Coloque la parte
restante (20 pulg.) utilizando la marca
de alineación de la teja. Vea la Fig. 8B.
Cuarta hilera: Corte 25 pulg. del
borde de la teja completa de la cuarta
hilera. Coloque la parte restante (15
pulg.) utilizando la marca de alineación
de la teja. Vea la Fig. 8C.
Hileras siguientes: Para las hileras
siguientes, repita los mismos pasos de
la primera hilera hasta la cuarta hilera.
Vea la Fig. 8D.
Third course
Tercera hilera
Rake edge
Trim 20"
from
left edge
Borde de viga
inclinada
Recortar
20 pulg. del borde izquierdo
Fig. 8B
Aplicación de tejas en patrón de desplazamiento de 5 pulg. y 15 pulg.
Shingle Application 5" & 15" offset pattern
Hilera 3
3
rd course
20"
20"
First course
Línea de tiza horizontal
Rake edge
Primera hilera
Borde de viga
inclinada
Horizontal chalk line
8"
14
1
/
4
"
Fig. 8
Aplicación de tejas en patrón de desplazamiento de 5 pulg. y 15 pulg.
Shingle Application 5"& 15" offset pattern
Hilera 1
1st course
Second course
Segunda hilera
Rake edge
Trim 5"
from left edge
Borde de viga
inclinada
Allignment notch
Muesca de alineación
Recortar 5 pulg. del
borde izquierdo
Fig. 8A
Aplicación de tejas en patrón de desplazamiento de 5 pulg. y 15 pulg.
Shingle Application 5" & 15" offset pattern
Hilera 2
2nd course
5"
15"
5"
40"
35"
88
Fourth course
Cuarta hilera
Rake edge
Trim 25"
from left edge
Borde de viga
inclinada
Recortar
25 pulg. del borde izquierdo
Fig. 8C
Aplicación de tejas en patrón de desplazamiento de 5 pulg. y 15 pulg.
Shingle Application 5" & 15" offset pattern
25"
Hilera 4
4th course
5"
15"
15"
5"
Succeeding courses
Hileras siguientes
Fig. 8D
Aplicación de tejas
Shingle Application
Hilera 5
5th course
15"
5"
15"
5"
40"
45575_OC_instructions.indd 745575_OC_instructions.indd 7 11/8/06 1:52:41 PM11/8/06 1:52:41 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
99
6
Valley Construction:
Open Valley
Lay a 36" wide valley liner of Owens Corning WeatherLock
®
underlayment or equivalent. A 36" wide minimum 50-lb. smooth
surface roll roofing can also be used as a valley liner. Fasten on
outer edges only a minimum of 6" away from centerline on each
side of valley. See Fig. 9.
Recommended valley flashing is 24" wide 26-gauge galvanized
metal or an equivalent corrosion-resistant, nonstaining mate-
rial. Secure the valley metal to the roof deck along each edge
with fasteners spaced 8"–12" apart. Overlaps should be 12" and
cemented. See Fig. 9.
Snap a chalk line on each side of the valley centerline over the
full length of the valley flashing. Space the chalk lines 6" apart at
the ridge (3" to either side of the valley centerline). The lower
ends of the chalk lines should diverge from each other
1
/
8
" per
foot (i.e., for an 8' valley the chalk lines will be 7" apart at the
eaves). See Fig. 9A.
As the shingles are applied toward the valley, the last shingle
in each course will be trimmed to fit on the chalk line. Note:
Do not use a shingle less than 12" in length to finish a
course running into a valley. If necessary, trim a tab off the
adjacent shingle in the course to allow a longer portion to
be used.
Clip 1" from the upper portion of the shingle on a 45° angle to
divert water into the valley. See Fig. 9A.
Cement the shingle to the valley lining with a 3" wide band of
asphalt plastic cement conforming to ASTM D 4586, Type I or II.
See Fig. 9A.
Construcción del canal:
Canal descubierto
Coloque un recubrimiento para canaletas de 36 pulg. de
ancho de impermeabilizante WeatherLock
®
de Owens
Corning o su equivalente. También se puede usar como
canaleta un rollo de superficie lisa para techos de 36 pulg.
de ancho (50 lb. como mínimo). Sujételo en los bordes
externos solamente, a una distancia mínima de 6 pulg. de la
línea de central a cada lado de la canaleta. Vea la Fig. 9.
El revestimiento recomendado para el canal es un metal
galvanizado de calibre 26 y 24 pulg. de ancho, o de otro
material resistente a la corrosión y al óxido. Asegure la parte
metálica del canal a la superficie del techo por cada orilla
espaciando los sujetadores de 8 a 12 pulg. Las superposicio-
nes deben ser a 12 pulg. y estar cementadas. Vea la Fig. 9.
Marque una línea con una tiza en ambos lados de la línea
de centro del canal a lo largo de toda la longitud del
revestimiento del canal. Separe las líneas de tiza 6 pulg.
en la cumbrera (3 pulg. a cada lado de la línea de centro
del canal). Los extremos inferiores de las líneas de tiza deben
estar separadas entre sí
1
/
8
pulg. por cada pie (es decir, para
un canal de 8 pies, las líneas de tiza estarán separadas 7 pulg.
en los aleros). Vea la Fig. 9A.
A medida que se colocan las tejas hacia el canal, la última
teja de cada hilera debe ser recortada para quede en la
línea de tiza. Nota: No utilice tejas de menos de 12
pulg. de longitud para finalizar una hilera que llega
hasta el canal. Si es necesario, recorte una aleta de la teja
adyacente en la hilera para poder usar un tramo más largo.
Recorte 1 pulg. de la porción superior de la teja con un
ángulo de 45 para conducir el agua hacia el canal.
Vea la Fig. 9A.
Pegue con cemento la teja al recubrimiento del canal
utilizando una banda de cemento plástico de asfalto de
3 pulg. de ancho, en cumplimiento con las normas
ASTM D 4586, Tipo I ó II. Vea la Fig. 9A.
36" wide Owens Corning WeatherLock
®
or equivalent underlayment centered in valley
WeatherLock
®
de Owens Corning o de 36 pulg. de ancho
centrada en el canal
Clavar el impermeabilizante
a 1 pulg. del borde
Cemento de techo
de asfalto
Nail underlayment 1"
from the edge
Asphalt roofing
cement
Fasteners
Sujetadores
12" top lap
24" metal flashing
Asphalt roofing cement
Superposición superior
de 12 pulg.
Revestimiento metálico
de 24 pulg.
Cemento de techo
de asfalto
Fig. 9
Construcción con canal descubierto
Open Valley Construction
Fig. 9A
Construcción con canal descubierto
Open Valley Construction
Línea de centro de canal
Valley centerline
Revestimiento de canal metálico
Metal valley flashing
12" top lap
Superposición superior de 12 pulg.
Asphalt roofing cement
Cemento de techo de asfalto
Líneas de tiza alejándose
1
/
8
pulg. por cada pie
Chalk lines diverge
1
/
8
" per foot
End shingles trimmed to
chalk line and set in 3" width of cement
Tejas de extremo recortadas hasta la
línea de tiza y fijadas a 3 pulg. de ancho de cemento
Recorte 1 pulg. en la esquina a 45˚
1" clipped off corner at 45˚
45575_OC_instructions.indd 845575_OC_instructions.indd 8 11/8/06 1:52:41 PM11/8/06 1:52:41 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
7
Closed-Cut Valley See Fig. 9B.
A closed-cut valley can be used as an
alternative and is applied as follows:
Lay a 36" wide valley liner of Owens
Corning WeatherLock
®
underlayment
or equivalent. A 36" wide minimum
50-lb. smooth surface roll roofing can
also be used as a valley liner.
Lay all shingles on one side of valley
and across centerline of valley a mini-
mum of 12". Fasten a minimum of 6"
away from centerline on each side
of valley.
Strike a chalk line 2" from the
centerline of the unshingled side.
Apply shingles on the unshingled side
up to the chalk line and trim, taking
care not to cut the underlying shingles.
Clip upper corners of these shingles,
cement and fasten.
Both woven and metal valleys are
acceptable alternatives.
Canal con corte cerrado
Vea la Fig. 9B.
Un canal de corte cerrado puede
utilizarse como una alternativa y se
debe aplicar de la siguiente manera:
Aplique un recubrimiento para
canaletas de 36 pulg. de ancho de
impermeabilizante WeatherLock
®
de Owens Corning o su equivalente.
También se puede usar como canaleta
un rollo de superficie lisa para techos de
36 pulg. de ancho (50 lb. como mínimo).
Aplique todas las tejas en un lado del
canal y a lo largo de la línea central del
canal (12 pulg. como mínimo). Sujete
a una distancia mínima de 6 pulg. de la
línea central a cada lado de la canaleta.
Marque una línea con una tiza a
2 pulg. de la línea central del lado sin
tejas. Coloque las tejas en el lado sin
tejas hasta la marca de tiza y corte
teniendo cuidado de no cortar las
tejas superpuestas. Recorte los bordes
de las esquinas superiores de estas
tejas, adhiera cemento y sujete.
Ambos canales de tejido y metal son
alternativas aceptables.
Fig. 9B
Construcción con canal de corte cerrado
Closed-Cut Valley Construction
Centerline
Línea central
Valley liner
Bajopiso de la canalera
Keep nails 6" from
valley center
Mantenga los clavos
6 pulg. del centro del valle
2"
Underlayment
Bajopiso
99
45575_OC_instructions.indd 945575_OC_instructions.indd 9 11/8/06 1:52:42 PM11/8/06 1:52:42 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
8
Step Flashing:
Use 5" x 6" corrosion-resistant metal
where roof planes butt against vertical
sidewalls or chimneys. See Fig. 10.
Revestimiento
escalonado:
Utilice metal resistente a la corrosión
de 5 pulg. x 6 pulg. en lugares donde
los planos del techo se unen a
paredes verticales laterales o a
chimeneas. Vea la Fig. 10.
2
1
/
2
"
2
1
/
2
"
Revestimiento
metálico de
5 pulg. x 6 pulg.
6"
Metal flashing
5" x 6"
Superposición
superior de 2 pulg.
2" top lap
Fig. 10
Revestimiento escalonado
Step Flashing
Clavar revestimiento al techo
Nail flashing to roof
10 10
Hip & Ridge Application:
Use Owens Corning High Style
®
Hip & Ridge shingles.
Follow the application instructions as printed on the High Style
Hip & Ridge carton.
Colocación de caballetes y cumbreras:
Use las tejas de caballete y de cumbrera High Style
®
de
Owens Corning.
Siga las instrucciones de colocación como se
indican en la caja de caballetes y cumbreras High Style.
11 11
45575_OC_instructions.indd 1045575_OC_instructions.indd 10 11/8/06 1:52:42 PM11/8/06 1:52:42 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
45575_OC_instructions.indd 1145575_OC_instructions.indd 11 11/8/06 1:52:42 PM11/8/06 1:52:42 PM
Ad #: Trim (flat): 8.5" x 11" Acct. Manager: N. Amin Prefix: 45575
Caption: Bleed (flat): Art Director: J. Stoll Proof: 3
Client: Owens Corning Live (flat): Writer: Date: 4/22/05
Job #: 51-16700-125 Line Screen: 175/K+PMS485 Print Producer: B. O’Dea Studio Artist: sk-sk
Unit: Insert Pages Engraver: Traffic: L. Snell Art Producer: J. Sparrow
Fonts: Helvetica, Gill Sans(AD)
Prepared by DONER ADVERTISING • Southfield, MI 248-354-9700
For additional information on Owens Corning Exterior Systems or Insulation Systems,
visit our Web site at www.owenscorning.com
or call 1
-
800
-
GET
-
PINK.
OWENS CORNING WORLD HEADQUARTERS
ONE OWENS CORNING PARKWAY
TOLEDO, OHIO, USA 43659
1
-
800
-
GET
-
PINK
www.owenscorning.com
Pub. No. 59547-B. Printed in U.S.A. May 2005. THE PINK PANTHER
& ©1964
2005 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved.
The color PINK is a registered trademark of Owens Corning.
©2005 Owens Corning.
45575_OC_instructions.indd 1245575_OC_instructions.indd 12 11/8/06 1:52:42 PM11/8/06 1:52:42 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Owens Corning WTAU Guía de instalación

Tipo
Guía de instalación
Este manual también es adecuado para

en otros idiomas