GE 14292/ZW4003 Manual de usuario

Tipo
Manual de usuario
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave
network with other Z-Wave certified devices from other
manufacturers and/or other applications. All non-battery
operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
This Device supports Lifeline (association group 1) supporting 1 node for lifeline
communication. Group 1 must be assigned the Node ID of the primary controller
where unsolicited notifications will be sent. The Z-Wave controller should set this
association automatically after inclusion. Lifeline association only supports the
“Device Reset Locally” function. Refer to the instructions of your controller for any
available details on how this can be set.
Fr
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils
exempts de licence d’Industrie Canada. Son utilisation est sujette aux deux conditions suivantes :
1) cet appareil ne doit pas occasionner de brouillage préjudiciable et 2) cet appareil doit accepter
toutes les interférences reçues, notamment les interférences qui peuvent provoquer un
fonctionnement non désiré.
NOTE DE LA FCC : Le fabricant n’est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de ce
matériel. De telles modifications peuvent annuler le droit de l’utilisateur à utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont été
définies afin de fournir une protection raisonnable contre le brouillage préjudiciable en milieu
résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et, s’il n’est
pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage préjudiciable
aux communications radio. Il n’existe toutefois aucune garantie que des interférences ne se
produiront pas au sein d’une installation donnée. Si cet appareil occasionne un brouillage
préjudiciable à la réception radiophonique ou télévisuelle, il suffit d’allumer et d’éteindre l’appareil
pour déterminer sa responsabilité. Nous encourageons l’utilisateur à essayer de corriger ces
interférences en appliquant une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l’antenne de réception.
— Augmenter la distance entre l’appareil et le récepteur.
— Brancher l’appareil à une prise secteur différente de celle du récepteur.
— Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC concernant
l’exposition aux RF, aucune modification apportée à l’antenne ou au dispositif n’est autorisée. Toute
modification apportée à l’antenne ou au dispositif pourrait faire en sorte que le dispositif dépasse
les exigences d’exposition aux RF et pourrait annuler le droit de l’utilisateur à utiliser ce dispositif.
En
This device complies with part 15 of the FCC and Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user’s authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
— Consult the dealer or an experienced radio/TV technician for help
Important note: To comply with the FCC RF exposure compliance requirements, no change to
the antenna or the device is permitted. Any change to the antenna or the device could result in
the device exceeding the RF exposure requirements and void user’s authority to operate the device.
Es
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC y con
las especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria de Canadá
aplicables a aparatos exentos de licencia. El funcionamiento está sujeto a las siguientes dos
condiciones: (1) este dispositivo no debe provocar interferencia perjudicial, y (2) este dispositivo
debe aceptar toda interferencia que reciba, incluso la que pudiera causar un funcionamiento no
deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio o TV
ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas modificaciones
podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de Clase B,
de conformidad con el apartado 15 de las normas de la FCC. Estos límites están diseñados para
proveer protección razonable contra interferencias perjudiciales en una instalación residencial.
Este equipo genera, usa y puede irradiar energía de radiofrecuencias y, si no se instala y usa según
las instrucciones, puede provocar interferencia perjudicial a las radiocomunicaciones. No obstante,
no hay garantías de que no ocurrirá interferencia en una instalación en particular. Si este equipo
provoca interferencia perjudicial a la recepción de radio o televisión, lo que puede determinarse
encendiendo y apagando el equipo, se recomienda que el usuario intente corregir la
interferencia por medio de la implementación de una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que está
conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier cambio a
la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de exposición de
radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
FCC — U2ZZW4003A | IC: 6924A-ZW4003A
Jasco Products Company | Model: ZW4003 / 14292, 14293
CAN ICES-3(B) / NMB-3(B)
FCC / IC
All brand names shown are trademarks of their
respective owners.
Tous les noms de marque illustrés sont des
marques de commerce de leurs propriétaires
respectifs.
Todas las marcas que aparecen aquí
son marcas registradas de sus respectivos
dueños.
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
GE IS A TRADEMARK OF GENERAL ELECTRIC COMPANY
AND IS UNDER LICENSE BY
JASCO PRODUCTS COMPANY LLC,
10 E. MEMORIAL RD.,
OKLAHOMA CITY, OK 73114.
©JASCO 2015 | 14292, 14293 | ZW4003 | rev. 01/05/16 RT
In-wall Wireless
Smart Switch
Montage mural sans fil
intelligent
enfichable
Interruptor
inalàmbrico de pared
inteligente
MANUAL • MANUEL • MANUAL
Scan to view
installation guide
Balayez ce code pour
consulter le guide
d’installation.
Escanear para ver
la guía de instalación
14292
14293
ZW4003
Z-Wave® Certified Wireless Lighting Control
Certifié Z-Wave Commande d’éclairage sans fil
Control inalámbrico para iluminación certificado por Z-Wave®
ezzwave.com
RIESGO DE INCENDIO
RIESGO DE DESCARGA ELÉCTRICA
RIESGO DE QUEMADURAS
CONTROL DE EQUIPOS
ELECTRODOMÉSTICOS:
PROCEDA CON SUMA PRECAUCIÓN AL USAR LOS
DISPOSITIVOS Z-WAVE PARA CONTROLAR EQUIPOS
ELECTRODOMÉSTICOS. EL DISPOSITIVO Z-WAVE
PUEDE FUNCIONAR EN UNA HABITACIÓN DIFERENTE
A LA DEL EQUIPO CONTROLADO. ADEMÁS, PODRÍA
PRODUCIRSE UNA ACTIVACIÓN ACCIDENTAL SI SE
OPRIME EL BOTÓN INCORRECTO EN EL CONTROL
REMOTO. LOS DISPOSITIVOS Z-WAVE PUEDEN
ENCENDERSE AUTOMÁTICAMENTE DEBIDO A
EVENTOS CRONOMETRADOS PROGRAMADOS.
SEGÚN EL EQUIPO DEL QUE SE TRATE, ESTE
FUNCIONAMIENTO ACCIDENTAL O SIN SUPERVISIÓN
PODRÍA CREAR UNA SITUACIÓN PELIGROSA. POR
TALES MOTIVOS, RECOMENDAMOS LO SIGUIENTE:
NO USAR LOS DISPOSITIVOS Z-WAVE PARA
CONTROLAR CALENTADORES ELÉCTRICOS U OTROS
APARATOS ELECTRODOMÉSTICOS QUE PUDIERAN
IMPLICAR UN PELIGRO DEBIDO A UN ENCENDIDO
SIN SUPERVISIÓN, ACCIDENTAL O AUTOMÁTICO.
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-WAVE
DEVICES TO CONTROL APPLIANCES. OPERATION
OF THE Z-WAVE DEVICE MAY BE IN A DIFFERENT
ROOM THAN THE CONTROLLED APPLIANCE, ALSO
AN UNINTENTIONAL ACTIVATION MAY OCCUR IF
THE WRONG BUTTON ON THE REMOTE IS PRESSED.
Z-WAVE DEVICES MAY AUTOMATICALLY BE POWERED
ON DUE TO TIMED EVENT PROGRAMMING.
DEPENDING UPON THE APPLIANCE, THESE
UNATTENDED OR UNINTENTIONAL OPERATIONS
COULD POSSIBLY RESULT IN A HAZARDOUS
CONDITION. FOR THESE REASONS, WE RECOMMEND
THE FOLLOWING:
DO NOT USE Z-WAVE DEVICES TO CONTROL
ELECTRIC HEATERS OR ANY OTHER APPLIANCES
WHICH MAY PRESENT A HAZARDOUS CONDITION
DUE TO UNATTENDED OR UNINTENTIONAL OR
AUTOMATIC POWER ON CONTROL.
RISQUE D’INCENDIE
RISQUE DE CHOC ÉLECTRIQUE
RISQUE DE BRÛLURES
COMMANDE DES APPAREILS :
SOYEZ TRÈS PRUDENT LORSQUE VOUS UTILISEZ
LES DISPOSITIFS Z-WAVE POUR COMMANDER
LES APPAREILS. LE DISPOSITIF Z-WAVE PEUT
ÊTRE UTILISÉ DANS UNE SALLE DIFFÉRENTE DE
CELLE DANS LAQUELLE SE TROUVE L’APPAREIL
COMMANDÉ ET UNE ACTIVATION INVOLONTAIRE
PEUT AUSSI SE PRODUIRE SI LE MAUVAIS BOUTON
EST ACTIVÉ SUR LA TÉLÉCOMMANDE. LES
DISPOSITIFS Z-WAVE POURRAIENT ÊTRE ACTIVÉS
AUTOMATIQUEMENT À CAUSE D’UN ÉVÉNEMENT
PROGRAMMÉ. SELON L’APPAREIL, CES UTILISATIONS
INVOLONTAIRES ET SANS SUPERVISION PEUVENT
ENGENDRER UN RISQUE. POUR CES RAISONS, NOUS
RECOMMANDONS CE QUI SUIT :
N’UTILISEZ PAS LES DISPOSITIFS Z-WAVE POUR
COMMANDER LES RADIATEURS ÉLECTRIQUES OU
D’AUTRES APPAREILS QUI POURRAIENT PRÉSENTER
UN DANGER EN CAS DE COMMANDE D’ACTIVATION
IMPRÉVUE, INVOLONTAIRE OU AUTOMATIQUE.
AVERTISSEMENT
WARNING ADVERTENCIA
NOT FOR USE WITH MEDICAL OR LIFE
SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD NEVER BE
USED TO SUPPLY POWER TO, OR CONTROL THE
ON/OFF STATUS OF MEDICAL AND/OR LIFE
SUPPORT EQUIPMENT.
NE PAS UTILISER AVEC UN ÉQUIPEMENT
MÉDICAL OU DE SURVIE
LES DISPOSITIFS COMPATIBLES AVEC LA
TECHNOLOGIE Z-WAVE NE DEVRAIENT JAMAIS ÊTRE
UTILISÉS POUR ALIMENTER OU COMMANDER LA MISE
EN MARCHE OU L’ARRÊT DE L’ÉQUIPEMENT MÉDICAL
OU DE SURVIE.
SE PROHÍBE SU EMPLEO EN EQUIPO
MÉDICO O EQUIPO PARA EL
MANTENIMIENTO DE LAS FUNCIONES
VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA SE DEBEN USAR
PARA SUMINISTRAR ENERGÍA ELÉCTRICA AL EQUIPO
MÉDICO O AL EQUIPO PARA EL MANTENIMIENTO DE
FUNCIONES VITALES, NI PARA CONTROLAR EL ESTADO
DE ENCENDIDO O APAGADO DE DICHOS EQUIPOS.
If you have any problems or questions, contact our tech support team
at; 1-800-654-8483, option 1 Monday–Friday, 7:30–5pm CST
For the most up-to-date product support, accessories, electronic (PDF) format
manuals and more, visit www.jascoproducts.com/support.
• No user servicable parts in this unit.
Si vous avez des problèmes ou des questions, communiquez avec notre
équipe de soutien technique au 1-800-654-8483, option1, du lundi au vendredi,
de 7 h 30 à 17 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les accessoires,
les manuels en format électronique (PDF) et plus encore, visitez le site
www.jascoproducts.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l’utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro equipo técnico al número:
1-800-654-8483, opción 1 de lunes a viernes, de 7:30 a 5 p.m., hora estándar del
centro (CST).
Para recibir el soporte técnico más actualizado sobre productos,
accesorios, manuales en formato digital (PDF), entre otros,
visite www.jascoproducts.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
DO NOT RETURN THIS
PRODUCT TO THE STORE
NE RETOURNEZ PAS
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
STOP
WARRANTY
JASCO Products warrants this product to be free from manufacturing defects for a period of
two years from the original date of consumer purchase. This warranty is limited to the repair or
replacement of this product only and does not extend to consequential or incidental damage to
other products that may be used with this product. This warranty is in lieu of all other warranties,
expressed or implied. Some states do not allow limitations on how long an implied warranty
lasts or permit the exclusion or limitation of incidental or consequential damage, so the above
limitations may not apply to you. This warranty gives you specific rights, and you may also have
other rights which vary from state to state. Please contact Customer Service at 800-654-8483
(option 1) between 7:30AM – 5:00PM CST or via our website (www.jascoproducts.com) if the unit
should prove defective within the warranty period.
GARANTIE
JASCO Products garantit que ce produit est exempt de tout défaut de fabrication pour une
période de deux ans à compter de la date de l’achat original par l’acheteur. Cette garantie se
limite exclusivement à la réparation ou au remplacement de ce produit et n’est pas applicable
aux dommages indirects ou accessoires survenus sur d’autres produits utilisés avec ce produit.
Cette garantie se substitue à toute autre garantie expresse ou implicite. Certains États ne
permettent pas de restrictions quant à la durée d’une garantie implicite ou permettent l’exclusion
ou la limitation des dommages indirects et accessoires; il se peut, par conséquent, que cette
garantie ne s’applique pas dans votre cas. Cette garantie vous confère des droits juridiques précis;
vous pouvez jouir d’autres droits qui peuvent varier d’un État à l’autre. Veuillez communiquer
avec le service à la clientèle au 1-800-654-8483 (option 1) entre 7 h 30 et 17 h (heure normale
du Centre) ou par l’intermédiaire de notre site Web (www.jascoproducts.com) si l’appareil s’avère
défaillant au cours de la période de garantie.
GARANTÍA
JASCO Products garantiza que este producto está libre de defectos de fabricación durante un
periodo de dos años a partir de la fecha original de compra por parte del consumidor. Esta
garantía se limita a la reparación o sustitución de este producto solamente y no se extiende
a daños derivados o accidentales causados a otros productos que se usen con esta unidad.
Esa garantía remplaza a todas las demás garantías expresas o implícitas. Algunos estados
no autorizan limitaciones en cuanto a la duración de una garantía implícita ni permiten la
exclusión o limitación por daños accidentales o derivados; por lo tanto, puede que las anteriores
limitaciones no apliquen en su caso. Esta garantía le da a usted derechos específicos, y otros
que usted puede tener y que varían según el estado en el que usted reside. Si la unidad resultare
defectuosa dentro del periodo de garantía, comuníquese por favor con Atención al Cliente en el
800-654-8483 (opción 1) entre 7.30 y 17 h, Hora del Centro, o a través de nuestro sitio de internet
(www.jascoproducts.com).
JASCO Products Company, Building B
10 E Memorial Rd. Oklahoma City, OK 73114
SPECIFICATIONS
ZW4003
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.4/916 MHz.
Maximum Loads: 960W, incandescent, ½ HP Motor or 1800W (15A) Resistive
Range: Up to 150 feet line of sight between the Wireless Controller and the closest Z-Wave
receiver module.
Operating Temperature Range: 32-104° F (0-40° C).
For indoor use only.
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW4003
Tension : 120 V c.a., 60 Hz.
Signal (fréquence) : 908.4/916 MHz.
Charges maximales : 960 watts (incandescent), moteur de ½ HP ou résistance de 1800 W (15 A).
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus proche
allant jusqu’à 150 pi.
Plage de températures de fonctionnement : de 32 à 104 °F (de 0 à 40 °C).
Utilisation intérieure uniquement.
En raison d’améliorations continues du produit, les spécifications peuvent faire l’objet de
changements sans préavis.
ESPECIFICACIONES:
ZW4003
Energía: 120 VCA, 60 Hz.
Señal (Frecuencia): 908.4/916 MHz.
Cargas máximas: 960 W, incandescente, ½ HP motor o 1800 W (15 A) resistiva
Alcance: Hasta 150 pies (45.72m) en línea de visibilidad directa entre el control inalámbrico y el
módulo receptor Z-Wave más cercano.
Rango de temperatura de funcionamiento: 32-104° F (0-40° C).
Para uso en espacios interiores solamente.
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto
White (Neutral)
Green (Ground)
Black (Line / Hot)
Z-Wave
Single
Switch
Black
(Load)
Tools You Will Need
1.
Turn ON/OFF manually or remotely via the Z-Wave controller
Can be Included in multiple Groups and Scenes
May be used in single pole installation or with up to two Jasco Add-on switches in
3-way or 4-way wiring configurations
Compatible with all incandescent and CFL/LED bulbs
Uses a standard, toggle wall plate for single gang installations (wall plate not
included)
Z-Wave Certified for simple pairing and integrated home automation
Screw Terminal Installation — requires wiring connections for Line (Hot), Load,
Neutral, and Ground. Traveler wire required for 3-way or 4-way installation
This Z-Wave device has advanced features that allow you to customize your
experience. These features can only be adjusted by a Z-Wave enabled controller
that support the Z-Wave Configuration command class. For a complete list of
Adjustable Configurations, visit: www.jascoproducts.com/z-waveconfig
Getting To Know Your New Z-Wave Device
IMPORTANT!
The fixture controlled by the Z-Wave In-wall Smart Switch must not exceed 960
watts (Incandescent). The switch is designed only for use with permanently
installed fixtures.
A. Up— (Press up & release to turn
switch on)
B. Down — (Press down & release
to turn switch off)
C. Ground (Green/Bare)
D. Load (Black)
E. Line (Black)
F. Traveler (Red/Other)
G. Neutral (White)
Single, Dual And Triple Gang Boxes
When installing the In-wall smart switch in multiple gang boxes it may
be necessary to break off one or both sides of the scored tabs on the
front yoke. This does not affect the electrical rating of the switch (see
specifications for details).
AD
E G
F
B
C
2.
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the service
panel. All wiring connections must be made with the POWER OFF to avoid personal
injury and/or damage to the switch.
This device is intended for installation in accordance with the National Electric Code
and local regulations in the United States, or the Canadian Electrical Code and local
regulations in Canada. If you are unsure or uncomfortable about performing this
installation consult a qualified electrician.
Multi-switch Wiring
For 3-way installations, please refer to Add-on Switch (45741/45761) manual
1. Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wall plate.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch box. DO NOT disconnect the wires.
5. There are up to five screw terminals on the Switch; these are marked:
A. LINE (Hot) — Black (connected to power)
B. NEUTRAL — White
C. LOAD — Black (connected to lighting)
D. GROUND — Green/Bare
E. TRAVELER — Red/Other (only in 3-way installations)
Match these screw terminals to the wires connected to the existing switch.
6. Disconnect the wires from the existing switch. Be careful to label wires according to
the previous terminal connection.
Observe Important Wiring Information
IMPORTANT! This switch is rated for and intended to only be used with copper wire.
Wire Gauge Requirements
Use 14 AWG or larger wires suitable for at least 80° C for supplying Line (HOT), Load,
Neutral, Ground and Traveler connections.
Wire Strip Length:
For attachment to screw terminals: Strip insulation 1” (25mm)
For attachment using the enclosure’s holes: Strip insulation 5/8” (16mm)
UL specifies that the tightening torque for the screws is 14 Kgf-cm (12 lbf-in).
1. Connect the green or bare copper ground wire to the GROUND terminal.
2. Connect the black wire that goes to the fixture to the terminal marked LOAD.
3. Connect the black wire that comes from the electrical service panel (Hot) to the
terminal marked LINE.
4. Connect the white wire to the neutral terminal (use included jumper wire if needed).
NOTE: The Traveler terminal is only used for 3-way or 4-way wiring and should remain
insulated if the switch is being installed in a 2-way system (one switch & one load).
5. Insert Switch into the switch box being careful not to pinch or crush wires.
6. Secure the switch to the box using the supplied screws.
7. Mount the wall plate.
8. Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic Operation
The connected light can be turned ON/OFF in two ways:
1. Manually from the front panel of the In-wall switch
2. Remotely with a Z-Wave Controller
Manual Control
The Front Panel Toggle Switch allows the user to:
Turn ON/OFF the connected fixture.
To turn the connected fixture ON: Press and release up on the toggle.
To turn the connected fixture OFF: Press and release down on the toggle.
OR
OR
From Breaker Box
Out to Light (Load)
A
B
E
D
C
Out to Light (Load)
A
D
E
C
B
From Breaker Box
3.
Adding your device to a Z-wave network:
1. Follow the instructions for your Z-wave certified controller to include a
device to the Z-wave network.
2. Once the controller is ready to include your device, press up and release
the toggle to include it in the network.
Please reference the controller’s manual for instructions.
Now you have complete control to turn your fixture ON/OFF or dim according
to groups, scenes, schedules and interactive automations programmed by
your controller.
If your Z-wave certified controller features Remote Access, you can now
control your fixture from your mobile devices.
To remove and reset the device
1. Follow the instructions for your Z-wave certified controller to exclude a
device from the Z-wave network.
2. Once the controller is ready to Exclude your device, press up and release
the toggle to exclude it from the network.
To return your switch to factory defaults:
1. Quickly press ON (Up) button three (3) times then immediately press the
OFF (Down) button three (3) times.
Note: This should only be used in the event your network’s primary
controller is missing or otherwise inoperable.
4. The GE Add-on switch is required for Multi-Switch 3-way or 4-way installations.
Connecting the traveler terminal of this switch to a standard, non-GE switch will cause
damage or result in improper function. If this switch is a part of a 3-way or 4-way multi-
switch installation, do not connect the traveler wire or apply power until GE Add-on
switches are correctly installed. For more information on 3-Way or 4-Way installations,
view the manual or quick-start guide that comes with the GE Add-on switch.
NewAssociationStatement
ThisdevicesupportsAssociationCommandClass(3Groups)
AssociationGroup1supportsLifeline,BinarySwitchReport
AssociationGroup2supportsBasicSetandiscontrolledwiththelocalload
AssociationGroup3supportsBasicSetandiscontrolledbydoublepressingtheOnorOffbutton
EachAssociationGroupsupports5totalnodes
  • Page 1 1
  • Page 2 2

GE 14292/ZW4003 Manual de usuario

Tipo
Manual de usuario