Sunbeam SCM630BC-NUM Manual de usuario

Categoría
Humidificadores
Tipo
Manual de usuario

Este manual también es adecuado para

Folleto de instrucciones
LEA Y CONSERVE ESTAS IMPORTANTES INSTRUCCIONES
Instruction Leaflet
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS
INFORMACION DE LA GARANTIA
141068/9100030007181 SCM630/631UM11ESM1 Impreso en China
GCDS-SUN20400-JC
© 2011 Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions. Todos los derechos reservados.
Distribuido por Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions, Boca Raton, Florida 33431.
GARANTÍA L I M I TADA D E 1 A Ñ O
Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions, o en Canadá, Sunbeam Corporation
(Canada) Limited operando bajo el nombre de Jarden Consumer Solutions, (en forma conjunta, “JCS”), garantiza que por
un período de uno año a partir de la fecha de compra, este producto estará libre de defectos de materiales y mano de obra.
JCS, a su elección, reparará o reemplaza este producto o cualquier componente del mismo que presente defectos durante
el período de garantía. El reemplazo se realizará por un producto o componente nuevo o reparado. Si el producto ya no
estuviera disponible, se lo reemplazará por un producto similar de valor igual o superior. Ésta es su garantía exclusiva. No
intente reparar o ajustar ninguna función eléctrica o mecánica de este producto. Al hacerlo elimínará ésta garana.
La garantía es válida para el comprador minorista original a partir de la fecha de compra inicial y la misma no es
transferible. Conserve el recibo de compra original. Para solicitar servicio en garantía se requiere presentar un recibo de
compra. Los agentes y centros de servicio de JCS o las tiendas minoristas que venden productos de JCS no tienen derecho
a alterar, modificar ni cambiar de ningún otro modo los términos y las condiciones de esta garantía.
Esta garantía no cubre el desgaste normal de las piezas ni los daños que se produzcan como resultado de uso negligente o
mal uso del producto, uso de voltaje incorrecto o corriente inapropiada, uso contrario a las instrucciones operativas, y
desarme, reparación o alteración por parte de un tercero ajeno a JCS o a un Centro de Servicio autorizado por JCS.
Asimismo, la garantía no cubre actos fortuitos tales como incendios, inundaciones, huracanes y tornados.
¿Cuál es el límite de responsabilidad de JCS?
JCS no será responsable de daños incidentales o emergentes causados por el incumplimiento de alguna garantía o
condición expresa, implícita o legal.
Excepto en la medida en que lo prohíba la ley aplicable, cualquier garantía o condición implícita de comerciabilidad o
aptitud para un fin determinado se limita, en cuanto a su duración, al plazo de la garantía antes mencionada.
JCS queda exenta de toda otra garantías, condiciones o manifestaciones, expresa, implícita, legal o de cualquier otra naturaleza.
JCS no será responsable de ningún tipo de daño que resulte de la compra, uso o mal uso del producto, o por la
imposibilidad de usar el producto, incluidos los daños incidentales, especiales, emergentes o similares, o la pérdida de
ganancias, ni de ningún incumplimiento contractual, sea de una obligación esencial o de otra naturaleza, ni de ningún
reclamo iniciado contra el comprador por un tercero.
Algunas provincias, estados o jurisdicciones no permiten la exclusión o limitación de los daños incidentales o emergentes ni
las limitaciones a la duración de las garantías implícitas, de modo que es posible que la exclusión o las limitaciones antes
mencionadas no se apliquen en su caso.
Esta garantía le otorga derechos legales específicos y es posible que usted tenga otros derechos que varían de un estado,
provincia o jurisdicción a otro.
Cómo solicitar el servicio en garantía
En los Estados Unidos
Si tiene alguna pregunta sobre esta garantía o desea recibir servicio de garantía, llame al 1-888-264-9669 y podrá
obtener la dirección del centro de servicio que le resulte más conveniente.
En Canadá
Si tiene alguna pregunta sobre esta garantía o desea recibir servicio de garantía, llame al 1-888-264-9669 y podrá
obtener la dirección del centro de servicio que le resulte más conveniente.
En los Estados Unidos, esta garana es ofrecida por Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer
Solutions, Boca Ran, Florida 33431. En Canadá, esta garantía es ofrecida por Sunbeam Corporation (Canada) Limited
operando bajo el nombre de Jarden Consumer Solutions, 20 B Hereford Street, Brampton, Ontario L6Y 0M1. Si usted tiene otro
problema o reclamo en conexn con este producto, por favor escriba al Departamento de Servicio al Consumidor. POR
FAVOR NO DEVUELVA ESTE PRODUCTO A NINGUNA DE ESTAS DIRECCIONES NI AL LUGAR DE COMPRA.
WA R R A N T Y I N F O R M ATION
Printed In China
© 2011 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions. All Rights Reserved.
Distributed by Sunbeam Products, Inc. doing business as Jarden Consumer Solutions, Boca Raton, Florida 33431.
1 YE AR LIM IT E D WARR AN TY
Sunbeam Products, Inc. doing business as Jarden Consumer Solutions or if in Canada, Sunbeam Corporation (Canada) Limited
doing business as Jarden Consumer Solutions (collectively “JCS”) warrants that for a period of one year from the date of
purchase, this product will be free from defects in material and workmanship. JCS, at its option, will repair or replace this
product or any component of the product found to be defective during the warranty period. Replacement will be made with a
new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar
product of equal or greater value. This is your exclusive warranty. Do NOT attempt to repair or adjust any electrical or
mechanical functions on this product. Doing so will void this warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the
original sales receipt. Proof of purchase is required to obtain warranty performance. JCS dealers, service centers, or retail
stores selling JCS products do not have the right to alter, modify or any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or
misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly,
repair or alteration by anyone other than JCS or an authorized JCS service center. Further, the warranty does not
cover: Acts of God, such as fire, flood, hurricanes and tornadoes.
What are the limits on JCS’s Liability?
JCS shall not be liable for any incidental or consequential damages caused by the breach of any express, implied or
statutory warranty or condition.
Except to the extent prohibited by applicable law, any implied warranty or condition of merchantability or fitness for a
particular purpose is limited in duration to the duration of the above warranty.
JCS disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise.
JCS shall not be liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use
the product including incidental, special, consequential or similar damages or loss of profits, or for any breach of
contract, fundamental or otherwise, or for any claim brought against purchaser by any other party.
Some provinces, states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages
or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from province to province,
state to state or jurisdiction to jurisdiction.
How to Obtain Warranty Service
In the U.S.A.
If you have any question regarding this warranty or would like to obtain warranty service, please call
1-888-264-9669 and a convenient service center address will be provided to you.
In Canada
If you have any question regarding this warranty or would like to obtain warranty service, please call
1-888-264-9669 and a convenient service center address will be provided to you.
In the U.S.A., this warranty is offered by Sunbeam Products, Inc. doing business as Jarden Consumer Solutions located
in Boca Raton, Florida 33431. In Canada, this warranty is offered by Sunbeam Corporation (Canada) Limited doing
business as Jarden Consumer Solutions, located at 20 B Hereford Street, Brampton, Ontario L6Y 0M1. If you have any
other problem or claim in connection with this product, please write our Consumer Service Department. PLEASE DO
NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE.
SCM630
SCM631
TRUSTED FOR OVER
100 YEARS
CONFIANZA
DESDE HACE
100 AÑOS
Cool Mist Tower
Humidif ier
DIAGNÓSTICO DE PROBLEMAS
PREGUNTA S F R E C U E N T E S
PREGUNTAS FRECUENTES
PREGUNTAS RESPUESTAS
WCuáles son las variables que
afectan el tiempo de
funcionamiento?
El tiempo de funcionamiento estimado de este humidificador está basado en las
condiciones ambientales promedio. El tiempo de funcionamiento actual de su
humidificador depende de varios factores tales como :
El intercambio de aire en el cuarto donde se encuentra el humidificador.
La estructura del cuarto donde se encuentra el humidificador.
La temperatura del cuarto donde se encuentra el humidificador.
Los niveles de humedad en el cuarto donde se encuentra el humidificador.
La actividad de los ocupantes y la secuencia en que se abren y cierran las
puertas del cuarto donde se encuentra el humidificador.
El número de muebles presentes en el cuarto donde se encuentra el
humidificador.
Cómo quito la película del tanque
de agua?
Consulte las instrucciones diarias de mantenimiento. Se recomienda una
limpieza regular.
Cómo puedo extender el tiempo de
funcionamiento?
Haga funcionar la unidad en el modo más bajo.
Si su unidad tiene electrónicos, ajústela al nivel de humedad deseado. La
unidad se encenderá y apagará, extendiendo el tiempo de funcionamiento.
Llene el tanque al máximo, colóquelo en la base, deje que el agua se vacíe
en la base hasta que deje de burbujear, luego llene nuevamente el tanque
al máximo. Esto asegura una capacidad máxima de agua que extenderá el
tiempo de funcionamiento.
DIAGNÓSTICO DE PROBLEMAS
PROBLEMA
POSIBLE CAUSA SOLUCIÓN
La unidad no se enciende.
* No está enchufada.
* El omacorriente no
funciona.
4 Enchúfela.
4 Haga reemplazar el tomacorriente por un
electricista matriculado.
Salida de vapor mínima o
nula.
* La niebla fría es invisible.
* El filtro no ha absorbido el agua.
4 Funcionamiento en configuración High (alta).
4 Espere 30 minutos para que el filtro absorba el agua.
El filtro se pone marrón. * El filtro ha absorbido
minerales.
4 Reemplace su filtro (HWF100 / SF235) llamando
al 1-888-264-9669, o visite
www.sunbeam.com
.
El FilterCheck
®
no está
funcionando.
* Demora 60 minutos
registrarse.
4 Permita que el humidificador funcione continuamente
durante 60 minutos para que el indicador del
FilterCheck
®
refleje el estado del filtro.
El humidificador muestra
constantemente un 25%.
* La humedad del
humidificador está en un
nivel inferior o igual al 25%.
4 Permita que su humidificador siga funcionando
para aumentar la humedad de la habitación.
El humidificador muestra
constantemente un 80%.
* La humedad del humidificador
se encuentra en 80% o más.
4 Detenga el funcionamiento del humidificador si el
nivel de humedad es muy alto.
TROUBLESHOOTING FREQUENTLY A S K E D Q U E S T I O N S
FREQUENTLY ASKED QUESTIONS
Question Answer
What are the variables that affect
run time?
The estimated run time for this humidifier is based on average room
conditions. The actual run time of your humidifier is dependent on numerous
variables such as:
Air exchange in the room where the humidifier is placed.
Room construction of the room where the humidifier is placed.
Temperature of the room where the humidifier is placed.
Humidity levels in the room where the humidifier is placed.
Movement of occupants and the opening and closing of doors in the room
where the humidifier is placed.
Home furnishings in the room where the humidifier is placed.
How do I remove film on water
tank?
See Daily Maintenance instructions. Regular cleaning is recommended.
How can I extend the run time?
Run your unit on the lowest setting.
If your unit has electronics, set it to your desired humidity level. The unit
will turn on and off, which will extend the run time.
Fill the tank all the way full, place it on the base, let the water empty into
the base until it stops bubbling, then refill the tank full again. This ensures
maximum water capacity and will extend run time.
TROUBLESHOOTING
TROUBLE PROBABLE CAUSE SOLUTION
Unit does not turn on.
* Not plugged in.
* Outlet not functioning.
4 Plug in unit.
4 Have outlet replaced by a licensed electrician.
Mist output minimal to
none.
* Cool mist is invisible.
* The filter has not absorbed water.
4 Operate in High setting.
4 Wait 30 minutes for filter to absorb water.
Filter turns brown. * The filter has absorbed
minerals.
4 Replace your filter (HWF100 / SF235) by calling
1-888 -264-9669, or visiting
www.sunbeam.com
.
FilterCheck
®
is not
working.
* Takes 60 minutes to register. 4 Allow the humidifier to run continuously for 60
minutes for the FilterCheck
®
Indicator to reflect
the filter condition.
Humidifier continuously
displays 25%.
* Humidity at the humidifier is
at or below 25%.
4 Continue to operate humidifier to raise the room
humidity.
Humidifier continuously
displays 80%.
* Humidity at the humidifier is
at or above 80%.
4 Stop operating the humidifier if the humidity
level is too high.
Torre De Niebla Fría
Humidif icador
SCM630
SCM631
FILTRO
DE REPUESTO
WA R R A N T Y I N F O R M ATION
INFORMACION DE LA GARANTIA
Si tiene preguntas relacionadas con este producto o si está interesado en conocer otros productos Sunbeam
®
,
póngase en contacto con nuestro Departamento de Servicio al Cliente: llame al 1 (888) 264-9669 o visite nuestro
sitio web www.sunbeam.com.
FILTRO# : HWF100 / SF235
FILTRO TIPO : MECHAS
FILTER# : HWF100 / SF235
FILTER TYPE : WICK
If you have any questions regarding your product or would like to learn more about other Sunbeam
®
products, please
contact our Consumer Service Department at 1-888-264-9669 or visit our website at www.sunbeam.com.
SCM630_631C-UM_11ESM1.indd 1 5/9/11 3:14 PM
PLEASE READ AND SAV E T H E S E
IMPORTA N T S A F E T Y I N S T R U C T I O N S
FEAT U R E S - O P E R ATIONS
Room Humidity. The Timer icon ( ) will appear on
the LCD Display to indicate that the selected timer.
4. When timer is set, you may check the remaining time
while humidifier is still in operation. Press the Timer
Button and the remaining time (e.g., 7 Hr) will
illuminate on the LCD Display for 3 seconds.
5. To cancel the Timer feature, press the Timer Button
( ). The remaining time will appear on the screen. Turn
the toggle switch to 0 hours. The Timer will then be
cancelled.
REPLACING THE FILTERS
Through normal use, waterborne minerals and sediment
become trapped in the wick filter. The harder your water, the
greater the amount of minerals in the water, and the more
often you will need to change your filter.
You will be able to monitor the life of the filter in your
humidifier by checking the FilterCheck
®
Indicator.
NOTE: After 60 minutes of use, FilterCheck
®
Indicator will
move and indicate your filter condition.
A brand new filter will register in the section
reading GOOD filter. After frequent use of
your humidifier, the FilterCheck
®
Indicator
will let you know when the filters need to be
changed, see Figure 3.
When the needle is in the CHANGE section,
this means the proper amount of moisture is not getting into
your air due to the excessive minerals and sediment that
have become trapped on your filters. At this point, you
should replace your filter. It is important to change your filter
as indicated to obtain stated performance level.
To replace the filter, follow the steps below:
1. Turn the unit off and disconnect from the electrical
outlet.
2. Remove the tank from the housing.
3. Unlock the housing from the base by turning the lock
knob to the unlocked position.
4. Lift the housing straight up and place to the side.
5. Unlock the wick holder from the base by turning the lock
knob to the unlocked position.
6. Remove the wicks from the wick holder.
7. Follow the weekly cleaning instructions.
8. Insert new filters into the wick holder and lock the wick
holder back onto the base.
9. Replace the housing onto the base and lock it into place.
10. Fill the tank and place back into housing.
11. Repeat Operating Instructions.
It will take about 30 minutes for the humidifier to reach
maximum output.
NOTE: You can purchase replacement filters (model
HWF100 / SF235) at a local retailer, by calling
1-888-264-9669
, or by visiting
www.sunbeam.com
. It is
recommended that a replacement filter is purchased for
uninterrupted use.
CLEANING AND MAINTENANCE
INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry,
heated indoor air. To benefit most from the humidifier and
avoid product misuse, follow all instructions carefully. Please
note that this is an electrical appliance and requires attention
when in use.
In addition, if you do not follow the recommended care and
maintenance guidelines, micro-organisms may be able to
grow in the water within the water tank. You must routinely
follow the cleaning procedures that follow in order to ensure
proper, efficient operation of your humidifier. Proper
maintenance and cleaning is essential to the continued
performance of your unit and the avoidance of algae or
bacteria build-up.
Daily Maintenance
1. Be sure the unit is OFF and is disconnected from the
electrical outlet.
2. Remove the housing and the tank from the humidifier
and place in sink or tub.
3. Carry the base of the unit to the sink, remove the wick,
place in sink, drain any remaining water and rinse
thoroughly to remove any sediment or dirt. Wipe clean,
and dry with a clean cloth or paper towel.
4. Drain the water from the tank into the sink and rinse
tank thoroughly. Wipe clean, and dry with a clean cloth
or paper towel.
5. Put filters back into wick holder making sure the rivet
attaches to the holder. Lock the wick holder back into
place. Replace the housing and lock it into place. Refill
26. Do not move unit after it has been used until unit cools
completely.
27. Use both hands when carrying full tank of water.
PLEASE READ AND SAVE
THESE IMPORTANT SAFETY
INSTRUCTIONS
CONSUMER SAFETY INFORMATION
NOTE:
This is an electrical appliance and requires attention
when in use.
NOTE:
If moisture forms on the walls or windows of the
room, turn off the humidifier. The room already has plenty of
humidity and additional moisture may cause damage.
NOTE:
DO NOT block air inlet or outlet.
Cord and Plug Installation Safety Instructions:
The length of cord used on this appliance was selected to reduce
the hazards of becoming tangled in, or tripping over a longer
cord. If a longer cord is necessary an approved extension cord
may be used. The electrical rating of the extension cord must be
equal to or greater than the rating of the humidifier (refer to
the rating information placed on the humidifier). Care must be
taken to arrange the extension cord so that it will not drape
over the countertop or tabletop where it can be pulled on by
children or accidentally tripped over.
HOW COOL MIST WORKS
Your Sunbeam
®
Cool Mist humidifier draws dry air through
the rear air intake grill area. This air is then passed through
a moisture–laden wick filter, which retains the minerals and
deposits in the water. The resulting moist air is directed back
into the room from the top air grill.
NOTE:
This humidification system provides a cool, invisible
moisture output. It is normal not to see the mist.
NOTE:
A humidity level below 20% can be unhealthy and
uncomfortable. The recommended humidity level is between
40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched to OFF and the unit is
disconnected from the electrical outlet.
2. Select a location for your humidifier, on a flat surface,
about 4 inches (10 cm) away from the wall. DO NOT
place the humidifier on a finished floor or near furniture,
which can be damaged by too much moisture or water.
Place on a moisture resistant surface.
FILLING THE WATER TANK
1. Remove the tank from the housing of the humidifier by
grabbing the handle of the tank and pulling forward. Lift
the tank out of the housing and bring to the faucet. Turn
the tank upside down and twist off the tank cap by
turning counter clockwise. Fill tank with cool, fresh tap
water. DO NOT fill with warm water as this may cause
leaking. Replace the cap on tank FIRMLY.
2. When full, carry the tank to the humidifier and place it
into the housing. There is a locating tab located on the
tank base for easy guidance. The tank holds 1.2 gallons
of water. The tank will immediately begin to empty into
the base.
3. Plug the power cord into a 120V AC electrical outlet.
OPERATING INSTRUCTIONS
Power Button
1. Press the Power Button to turn the humidifier on, the
LCD Display shows the Room humidity level.
NOTE: The display range is 25% - 80%. If your room
humidity level falls below 25%, the unit will display 25.
If your room humidity level rises above 80%, the unit
will display 80.
2. The default is running the humidifier at the HIGH
manual setting.
3. Press the button again for the LOW manual setting. Once
selected, the Setting Indicators will illuminate to
indicate which setting is activated.
4. Press the button again will stop the unit. To shut off the
humidifier at any time of operation, press and hold the
button for two seconds, or keep pressing the button until
the display goes off.
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance directly
into a 120V AC electrical outlet.
3. Keep the cord out of heavy traffic areas. To avoid fire hazard,
NEVER put the cord under rugs or near heat registers.
4. DO NOT place humidifier near heat sources such as stoves,
radiators, and heaters. DO locate your humidifier on an
inside wall near an electrical outlet. The humidifier should be
at least 4 inches (10 cm) away from the wall for best results.
5. NEVER place humidifier in an area where it is accessible to
children. NEVER use humidifier in a closed room, particularly
where a child may be sleeping, resting, or playing (a closed
room may result in excessive humidity).
6.
WARNING:
Do not attempt to refill humidifier without
first unplugging the unit from its electrical outlet. Failure to
heed this warning may cause personal injury. Be sure to
unplug the unit by pulling on the plug and not the cord.
7. Never place anything over moisture outlet when the unit
is running.
8. NEVER drop or insert any object into any openings.
9. DO NOT operate any appliance with a damaged cord or
plug, after the appliance malfunctions, or if it has been
dropped or damaged in any manner. Return appliance
to manufacturer for examination, electrical or
mechanical adjustment, or repair.
10. Use appliance only for intended household use as described
in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to
persons. The use of attachments not recommended or sold
by the manufacturer may cause hazards.
11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface. A
waterproof mat or pad is recommended for use under
the humidifier. NEVER place it on a rug or carpet, or on
a finished floor that may be damaged by exposure to
water or moisture.
13. DO NOT allow the Moisture Outlet to directly face the wall.
Moisture could cause damage, particularly to wallpaper.
14. Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit.
16. This humidifier requires daily and weekly maintenance
to operate appropriately. Refer to daily and weekly
cleaning procedures. Use only cleaners and additives
recommended by the manufacturer.
17. NEVER use detergents, gasoline, glass cleaner, furniture
polish, paint thinner, or other household solvents to
clean any part of the humidifier.
18. Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
19. Do not use humidifier in an area where humidity level is
in excess of 50%. Use a hygrometer, available at your
local retailer or through the manufacturer, to measure
the humidity.
20. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed by
qualified personnel only.
21. Never place housing under water flow or immerse in liquids.
22. Do not plug in the cord with wet hands: electric shock
could result.
23. Do not pour water in any openings other than the water
tank.
24. To prevent damage to surfaces, do not place humidifier
under overhanging surfaces.
25. NEVER operate unit without water in the tank.
FEAT U R E S - O P E R ATIONS
REPLACING THE FILT E R S
CLEANING / MAINTENANCE
STORAGE INSTRUCTIONS
REPLACEMENT ACCESSORIES
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to
install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
Digital Humidistat Control
Your humidifier is equipped with a digital humidistat that
allows you to set your humidifier to your desired comfort
level. To preset a precise comfort level, turn the Toggle Switch
to adjust the humidity level ranging from 30% to 60% or
” setting for constant humidity. Humidity will increase
or decrease in increments of 5%. The LCD Display will show
the selected humidity level for 3 seconds and then change
back to show the room humidity. The Set humidity level will
illuminate on top left of the LCD Display. When the room
humidity level rises above the set humidity, the humidifier will
stop. When the room humidity level drops below the set humidity,
the humidifier will turn on automatically to maintain the preset
humidity level.
NOTE: To shut the humidifier off at any setting, press the
Power Button ( ). The humidistat has memory. This means
that when you turn the unit back on, it will be at the last
humidity setting before the humidifier is turned off. However,
if the humidifier is unplugged, the digital humidistat will no
longer remember the previous humidity setting. You will need
to reset the digital humidistat if the humidifier is unplugged.
WARNING: DO NOT move the humidifier with water in
the tank or the humidifier base. The moving action of the
water may activate the water tank’s release nozzle and
overfill the humidifier base. This may cause the
humidifier to function intermittently, or stop emitting
mist. Should this occurs, simply remove the excess water
from the humidifier base.
NOTES:
High setting will produce the maximum moisture level
and Low setting will produce the longest run time and
quieter performance.
The 9 holes below control panel are part of the
humidistat sensor.
Tank Empty
Once the tank is empty, turn off your humidifier and unplug
it from the electrical outlet. Before refilling, empty any
residual water from the base and the tank (follow the daily
maintenance instructions). Then follow the Filling Instructions
to refill the tank and put back into the humidifier to begin
operation.
Timer
Your humidifier is equipped with 24-Hour Auto Shut-off Timer
feature. This allows you to program your humidifier to shut
off automatically after running a defined time interval.
1. Press the Timer Button ( ) once. The "0" Hr icon will
begin to blink.
2. Turn the toggle switch to adjust from 0 to 24 to select
your desired time interval for the humidifier to shut-off
automatically.
3. The selected hour will appear on the LCD Display for 3
seconds and then the LCD Display will return to show the
CARACTERISTICA - FUNCIONAMIENTO
el tanque y volver a colocarlo dentro del humidificador
para su funcionamiento.
Temporizador
Su humidificador está equipado con la función de
temporizador de apagado automático a las 24 horas. Permite
programar el humidificador para que se apague de manera
automática luegode un plazo determinado.
1. Presione el Botón Temporizador ( ) una vez. El icono
de hora “0” empezará a titilar.
2. Gire el interruptor de conmutación para ajustar de 0 a
24 el intervalo de tiempo que desee seleccionar para
que el humidificador se apague automáticamente.
3. La hora seleccionada aparecerá en el Visor LCD durante
3 segundos y luego el Visor LCD volverá a mostrar la
Humedad ambiente. El icono Temporizador ( )
aparecerá en el visor LCD para indicar el temporizador
seleccionado.
4. Cuando el temporizador esté configurado, usted puede
verificar el tiempo restante mientras el humidificador
todavía está en funcionamiento. Presione el Botón
Temporizador y el tiempo restante (por ejemplo, 7 horas)
se encenderá en el visor LCD durante 3 segundos.
5. Para cancelar la función del Temporizador, presione el
botón Temporizador ( ). El tiempo restante
aparecerá en la pantalla. Gire la Interruptor de
conmutación hasta 0 horas. Entonces se cancelará el
Temporizador.
REEMPLAZO DE LOS FILTROS
Durante el uso normal de la unidad, los minerales y
sedimentos arrastrados por el agua quedan retenidos en el
filtro de mecha. Mientras más dura sea el agua, mayor será
el número de minerales que contenga, mientras mayor sea el
número de minerales en el agua, mayor será la frecuencia
en que tenga que cambiar el filtro.
Podrá monitorear la vida del filtro de su humidificador con el
indicador FilterCheck
®
.
NOTA: Trás 60 minutos de uso, el indicador
FilterCheck
®
se moverá e indicará la condición
de sus filtro.
Un filtro completamente nuevo se registrará
en la sección denominada Filtro BUENO.
Después de haber usado con bastante
frecuencia su humidificador, el indicador FilterCheck
®
le
avisará cuando tiene que cambiar su filtros, observe la Figura
3.
Cuando la aguja esté en el área CAMBIAR, significa que la
unidad no está emitiendo la humedad necesaria debido a la
excesiva cantidad de minerales y sedimentos que se
encuentran retenidos en el filtros. Ahora es cuando debe
reemplazar el filtro. Para obtener un mejor rendimiento, es
importante cambiar su filtro según se indica.
Para reemplazar el filtro, siga los siguientes pasos.
1. Apague la unidad y desenchúfela del tomacorriente.
2. Retire el depósito de la caja.
3. Desbloquee la caja de la base girando la perilla de
bloqueo hasta la posición de desbloqueo.
4. Levante la caja en línea recta y colóquela a un costado.
5. Desbloquee el soporte de mechas de la base girando la
perilla de bloqueo hasta la posición de desbloqueo.
6. Retire las mechas del soporte de mechas.
7. Siga las instrucciones para la limpieza semanal.
8. Inserte los filtros limpios en el soporte de mechas y
bloquéelo nuevamente en la base.
9. Vuelva a colocar la caja sobre la base y bloquéela en su
lugar.
10. Llene el depósito y colóquelo nuevamente en la caja.
11. Repita las Instrucciones de Funcionamiento.
Tomará aproximadamente 30 minutos para que el
humidificador alcance su potencia máxima.
NOTA:
Puede comprar repuestos de filtros (modelo HWF100 /
SF235) en una tienda local, llamando al 1-888-264-9669, ó
visitando
www.sunbeam.com
. Se recomienda que compre un filtro
de repuesto para no interrumpir el funcionamiento de la unidad.
INSTRUCCIONES DE LIMPIEZA Y
MANTENIMIENTO
Los humidificadores proveen confort agregando humedad al
aire seco de los ambientes interiores calefaccionados. Para
beneficiarse al máximo de los humidificadores y evitar su
mal uso, siga todas las instrucciones cuidadosamente. Tenga
en cuenta que éste es un artefacto eléctrico que requiere
atención cuando esté en uso.
Además, si no se siguen las recomendaciones para el cuidado y
mantenimiento, crecerán microorganismos en el agua dentro de
los tanques. Se deben ejecutar rutinariamente los procedimientos
de limpieza que se indican a continuación para asegurar el
23. No coloque agua en ninguna abertura que no sea el
tanque de agua.
24. Para prevenir el daño a las superficies, no coloque el
humidificador debajo de ninguna superficie que
sobresalga por encima del mismo.
25. NUNCA haga funcionar la unidad sin agua en el tanque.
26. Una vez utilizada la unidad, no la mueva hasta que se
haya enfriado completamente.
27. Use las dos manos cuando cargue el tanque de agua.
LEA Y CONSERVE ESTAS
IMPORTANTES
INSTRUCCIONES DE
SEGURIDAD
INFORMACIÓN DE SEGURIDAD PARA EL
CONSUMIDOR
NOTA:
Este es un artefacto eléctrico y requiere ser usado
con cuidado.
NOTA:
Si se acumula humedad en las paredes o ventanas del
cuarto, apague el humidificador. El cuarto ya tiene demasiada
humedad y la humedad adicional puede causar daños.
NOTA:
NO bloquee la entrada o salida de aire.
Instrucciones de Seguridad en la Instalación del
Cable y el Enchufe :
La longitud del cable de este artefacto fue seleccionada para
reducir el riesgo de enredarse o tropezarse con un cable más
largo. Si necesita usar un cable más largo, puede utilizar un cable
de extensn aprobado. La capacidad ectrica del cable de
extensión debe ser igual o mayor que la capacidad del
humidificador (consulte la información sobre clasificación que se
encuentra en el humidificador). No debe permitir que el cable de
extensión cuelgue de la mesada o mesa de tal forma que pueda
ser jalado por nos o causar que alguien se tropiece.
COMO FUNCIONA EL VAPOR FRÍO
Su humidificador Sunbeam
®
de Vapor Frío succiona aire seco a
través de la rejilla de entrada de aire. Luego, el aire pasa por 6
filtros de mecha cargados de humedad, los que retienen los
minerales y depósitos del agua. El aire húmedo resultante es
dirigido nuevamente al ambiente por la rejilla superior.
NOTA:
Este sistema de humidificación proporciona una salida
de humedad fría e invisible. Es normal que no se vea el vapor.
NOTA:
Un nivel de humedad menor al 20% puede ser
nocivo e incómodo. El nivel de humedad recomendado es
entre el 40% y el 50%.
INSTRUCCIONES PREVIAS AL USO
1. Asegúrese de que el humidificador esté en OFF y
desenchúfelo del tomacorriente.
2. Elija un lugar para su humidificador, en una superficie
plana, aproximadamente a 4 pulgadas de distancia de la
pared. NO coloque el humidificador sobre un piso pulido
o cerca de algún mueble, ya que lo puede dañar por el
exceso de humedad o agua. Colóquelo sobre una
superficie resistente a la humedad.
COMO LLENAR EL TANQUE DE AGUA
1. Retire el tanque de la carcasa del humidificador
agarrando la manija del tanque y tirando hacia
adelante. Levante el tanque fuera de la carcasa y llévelo
a la canilla. De vuelta el tanque y desenrosque la tapa del
tanque girando en sentido contrario a las agujas del reloj.
Llene el tanque con agua fría del grifo. NO llene con agua
caliente ya que puede producir una pérdida. Vuelva a
colocar la tapa del tanque CON FIRMEZA.
2. Cuando esté lleno, lleve el tanque hasta el humidificador y
colóquelo dentro de la carcasa. Hay una etiqueta ubicada en
la base del tanque para fácil orientacn. El tanque tiene una
capacidad de 5 litros de agua. El tanque comenza a
vaciarse inmediatamente en la base.
3. Enchufe el cable de corriente en un tomacorriente de
120 voltios AC.
INSTRUCCIONES DE USO
Botón Encendido
1. Presione el botón de encendido (power) del
humidificador, el visor LCD indicará el nivel de humedad
del ambiente.
NOTA: El rango del visor oscila entre el 25% y el 80%.
Si el nivel de humedad del ambiente se encuentra por
debajo del 25%, la unidad indicará 25. Si el nivel de
humedad del ambiente supera el 80%, la unidad
indicará 80.
CARACTERISTICA - FUNCIONAMIENTO
REEMPLAZO DE LOS FILT R O S
INSTRUCCIONES DE LIMPIEZA Y MANTENIMIENTO
INSTRUCCIONES PARA GUARDAR
ACCESORIOS DE REPUESTO
LEA Y CONSERVE ESTAS I M P O RTANTES
INSTRUCCIONES DE SEGURIDAD
Debe tomar precauciones básicas de seguridad siempre que
utilice artefactos eléctricos para reducir el riesgo de incendio,
descarga eléctrica y daños personales, incluyendo lo siguiente:
1. Lea completamente las instrucciones antes de utilizar el
artefacto.
2. Para evitar incendio o descarga eléctrica, enchufe el
artefacto directamente en un tomacorriente de 120V CA.
3. Mantenga el cable fuera de las zonas de mucho tráfico.
Para evitar incendios, NUNCA coloque el cable debajo de
alfombrillas o cerca de salidas de calefacción.
4. NO coloque el humidificador cerca de fuentes de calor
como estufas, radiadores y calefactores. NO coloque el
humidificador contra una pared interna cerca de un
tomacorriente. El humidificador debe estar a por lo
menos 4" de la pared para obtener el mejor resultado.
5. NUNCA coloque el humidificador en una zona accesible
para los niños. NUNCA use el humidificador en un cuarto
cerrado, especialmente donde pueda haber un niño
durmiendo, descansando, o jugando (un cuarto cerrado
puede resultar en excesiva humedad).
6. ADVERTENCIA: No intente llenar nuevamente el
humidificador sin antes desenchufarlo del tomacorriente.
El no tener en cuenta esta advertencia puede causar
daños personales. Asegúrese de desenchufar la unidad
tirando del enchufe y no del cable.
7. Nunca coloque algo sobre la salida de humedad cuando
la unidad esté funcionando.
8. NUNCA inserte ningún objeto en una de las ranuras.
9. NO utilice ningún artefacto si el cable o el enchufe están
dañados, luego de una falla, o si se ha caído o ha sufrido
cualquier tipo de daño. Devuelva el artefacto al fabricante
para su inspeccn, ajuste eléctrico o menico, o reparacn.
10. Utilice el artefacto únicamente para el propósito
hogareño indicado en este manual. Cualquier uso
distinto al recomendado por el fabricante puede causar
incendio, descarga eléctrica, o daños personales. El uso
de accesorios no recomendados o que no sean vendidos
por el fabricante puede ser peligroso.
11. NO utilizar en el exterior.
12. Siempre coloque el humidificador en una superficie
firme, plana y nivelada. Se recomienda el colocar una
alfombrilla o bandeja resistente al agua debajo del
humidificador. NUNCA lo coloque sobre un tapete o una
alfombra, o en un piso que pueda dañarse con el agua o
la humedad.
13. NO haga que la salida de humedad apunte directamente
a la pared. La humedad puede causar daños,
especialmente al empapelado.
14. Se debe desenchufar el humidificador cuando no se usa.
15. NUNCA incline, mueva o intente vaciar la unidad
mientras esté funcionando. Apague y desenchufe la
unidad antes de quitar el tanque de agua y moverla.
16. Este humidificador requiere mantenimiento diario y
semanal para funcionar correctamente. Refiérase a los
procedimientos de limpieza diarios y semanales. Use
únicamente limpiadores y aditivos recomendados por el
fabricante.
17. NUNCA use detergentes, gasolina, limpiavidrios, limpiador
de muebles, diluyente de pintura u otro solvente
hogareño para limpiar ninguna parte del humidificador.
18. La humedad excesiva en un cuarto puede causar
condensación de agua en las ventanas y en algunos
muebles. Si sucede esto, apague el humidificador.
19. No use el humidificador en un área donde el nivel de
humedad es mayor al 50%. Use un Higrómetro,
disponible en su tienda local o a través del fabricante,
para medir la humedad.
20. NO intente reparar o ajustar ninguna función eléctrica o
mecánica de esta unidad. El hacerlo invalidará la
garantía. La unidad no contiene partes reparables por el
usuario. Toda reparación debe ser realizada únicamente
por personal calificado.
21. Nunca coloque el gabinete debajo de la canilla o lo
sumerja en líquidos.
22. No enchufe el cable con las manos húmedas. Puede
ocasionarle una descarga eléctrica.
ESTE PRODUCTO TIENE UN ENCHUFE POLARIZADO (una hoja es más
ancha que la otra). A fin de disminuir el riesgo de descarga eléctrica, este
enchufe está diseñado para insertarse en un tomacorriente polarizado en
un solo sentido. Si el enchufe no entra completamente en el tomacorriente,
inviértalo. Si aun así no entra, llame a un electricista calificado para
instalar un tomacorriente apropiado.
NO MODIFIQUE EL ENCHUFE NI ANULE ESTA FUNCION DE SEGURIDAD
DE NINGUNA MANERA.
2. La configuración predeterminada del humidificador
opera en manual alta (HIGH).
3. Presione nuevamente el botón para establecer la
configuración manual baja (LOW). Una vez seleccionada,
los Indicadores de configuración se iluminarán para
indicar qué configuración fue activada.
4. Presione nuevamente el botón para detener la unidad.
Para apagar el humidificador en cualquier instancia de la
operación, presione y mantenga presionado el botón por
dos segundos, o hasta que el visor se apague.
Control digital del medidor de humedad
El humidificador está equipado con un medidor de humedad
digital que le permite configurar su humidificador al nivel
deseado. Para predeterminar un nivel específico que resulte
cómodo, gire el Interruptor de conmutación para ajustar un
nivel de humedad del 30% al 60% o ” (constante)
para establecer una humedad constante. La humedad
aumentará o disminuirá en incrementos del 5%. El visor LCD
mostrará el nivel de humedad seleccionado durante 3 segundos
y luego volverá a mostrar la temperatura ambiente. El nivel de
humedad especificado aparecerá iluminado en el extremo
superior izquierdo del visor LCD. Cuando el nivel de humedad
del ambiente ascienda por encima de la humedad establecida,
el humidificador se detendrá. Cuando la humedad del ambiente
sea menor a la establecida, el humidificador se encenderá de
manera automática para mantener el nivel de humedad
configurado previamente.
NOTA: Para apagar el humidificador en cualquier
configuración, presione el Botón Encendido ( ). El medidor
de humedad tiene memoria. Significa que cuando lo vuelva a
encender, la unidad tendrá la última configuración de
humedad que tenía antes que se apagara el humidificador.
Sin embargo, si el humidificador está desenchufado, el
medidor de humedad digital no recordará la configuración de
humedad previa. Deberá reiniciar el medidor de humedad
digital si el humidificador está desenchufado.
ADVERTENCIA: NO MUEVA el humidificador cuando
tenga agua en el tanque o en la base. La acción de
movimiento podría activar la boquilla de descarga del
tanque de agua y saturar la base del humidificador. Si
sucediera, el humidificador funcionaría intermitentemente
y dejaría de emitir vapor. En este caso, simplemente
elimine el exceso de agua de la base del humidificador.
NOTAS:
La posición alta producirá el máximo nivel de
humedad y una posición baja ofrecerá el mayor
tiempo de uso y un funcionamiento más silencioso.
Los 9 orificios en la parte inferior de la panel de control
constituyen el sensor del medidor de humedad.
Tanque vacío
Una vez que el tanque se encuentre vacío, apague el
humidificador y desconéctelo del tomacorrientes. Antes de
llenarlo nuevamente, vacíe el tanque y la base de todo resto
de agua (siga las instrucciones de mantenimiento diario). A
continuación, siga las Instrucciones de llenado para rellenar
Figure 3
Figura 3
A. Tank
B. Tank Handle
C. Base
D. Humidifier Housing
E. Control Panel
F. FilterCheck
®
Indicator
Figure 1
C
F
E
B
A
D
A. Power Button
B. Toggle Switch
C. LCD Display
D. Timer Button
Figure 2
C
B
A
D
A. Botón de encendido
(power)
B. Interruptor de
conmutación
C. Visor LCD
D. Botón del
temporizador (timer)
Figura 2
C
B
A
D
C
F
E
B
A
D
A. Tanque
B. Manija
C. Base
D. Cubierta del
humidificador
E. Panel de control
F. Indicador FilterCheck
®
Figura 1
the tank with cool tap water as instruction earlier in the
filling instructiosn. Do not overfill.
6. Follow Operating Instructions.
NOTE: The Tray is dishwasher safe (TOP RACK ONLY)
for easy cleaning.
Weekly Maintenance
To Remove Scale:
1. Repeat steps 1-4 above.
2.
Clean the base by partially filling the base with one 8-oz
cups of undiluted white vinegar, or by using Cleanse
Clean
®
solution (Model S1710) by the manufacturer.
Leave this solution in the base for 20 minutes, while
cleaning all the interior surfaces with a soft brush.
Remove base scale by wiping the base with a cloth
dampened with undiluted white vinegar.
3. Rinse with clean warm water to remove the cleaning
solution before disinfecting the tank.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier tank 1/2 full with water and 1/2
tablespoon of chlorine bleach.
2. Let the solution stand for 20 minutes, swishing every
few minutes. Wet all surfaces.
3. Carefully empty the tank after 20 minutes, and rinse
with warm water until you cannot detect any bleach
smell. Dry with a clean cloth or paper towel.
4. Place filter back into tank and refill the water tank as
directed in Operating Instructions, and turn the unit on.
STORAGE INSTRUCTIONS
When not using your humidifier for an extended period of time:
1. Dispose of the filters. DO NOT leave in unit.
2. Clean, rinse and thoroughly dry the humidifier as
directed in weekly maintenance. DO NOT leave any
water in the unit when storing. Leaving water in the unit
may render the unit inoperable for the following season.
3. Place the humidifier in the original carton and store in a
cool, dry place.
4. Order your replacement filter for next year’s use.
REPLACEMENT ACCESSORIES
To order the replacement accessories you can do any of the
following:
Visit your local retailer
Go to
www.sunbeam.com
Call Consumer Service at 1-888-264-9669
funcionamiento adecuado y eficiente del humidificador que
son esenciales para el rendimiento óptimo constante de la
unidad y para evitar la formación de algas y bacterias.
Mantenimiento diario
1. Asegúrese de apagar y desenchufar la unidad del
tomacorriente.
2. Desmonte el casco y los tanques del humidificador y
colóquelos en el fregadero o en la tina.
3. Lleve la base de la unidad al fregadero o a la tina, quítele
el filtro de mecha, coloque la base en el fregadero, drene
el agua remanente, enjeague completamente para
remover cualquier sedimento o suciedad, limpie frotando
con un paño y seque con una toalla de tela o papel.
4. Drene el agua de los tanques en el fregadero y
enjuáguelos completamente. Límpielos frotando con un
paño y séquelos con una toalla de tela o de papel.
5. Vuelva a colocar los filtros en el soporte de la mecha
asegúrese de que el remache esté sujeto al soporte.
Sujete el soporte de la mecha en su lugar. Vuelva a
poner la carcasa en su lugar. Vuelva a llenar el tanque
con agua fría como se detalla anteriormente en las
instrucciones de llenado. No lo llene de más.
6. Siga las instrucciones de operación.
NOTA: La bandeja es apta para lavavajillas (SOLO EN
EL ESTANTE SUPERIOR) para fácil lavado.
Mantenimiento semanal
Para extraer el sarro :
1. Repita los pasos 1 al 4 anteriores.
2. Limpie la base llenándola parcialmente con una taza de
250 ml (8 oz.) de vinagre blanco sin diluir o con
Cleanse
Clean
®
solución
(Modelo S1710)
. Deje reposar esta
solución en la base por 20 min. mientras limpia todas
las superficies interiores con un cepillo blando. Quite el
sarro frotando la base con un trapo humedecido con
vinagre blanco sin diluir.
3. Enjuague con agua tibia limpia para extraer la solución
limpiadora antes de desinfectar el tanque.
Para desinfectar la base y los tanques del
humidificador :
1. Llene cada tanque hasta la mitad con agua y 1/2
cucharadita de blanqueador de cloro.
2. Deje que la solución trabaje por 20 minutos, sacudiendo
los tanques de vez en cuando. Moje todas las superficies.
3. Vacíe cuidadosamente la base y los tanques después de
20 minutos y enjuague hasta que ya no se pueda
detectar el olor a cloro. Seque con una tela limpia o con
toalla de papel.
4. Coloque el filtro nuevamente en el tanque y vuelva a
cargar el tanque de agua como se indica en las
Instrucciones de Funcionamiento, y encienda la unidad.
INSTRUCCIONES PARA GUARDAR
Cuando no utilice su humidificador durante un período
prolongado de tiempo :
1. Elimine los filtros. NO los deje dentro de la unidad.
2. Limpie y seque bien el humidificador según se detalla
anteriormente en la sección: instrucciones de
mantenimiento semanales. NO deje agua dentro de la
unidad cuando guarde el humidificador. Si queda agua,
la unidad podría quedar inutilizable para la próxima
temporada.
3. Coloque el humidificador en su empaque original y
guárdelo en un lugar fresco y seco.
4. Encargue su filtro de repuesto para el próximo año.
ACCESORIOS DE REPUESTO
Puede ordenar accesorios de repuesto de una de las
siguientes formas :
Visite su distribuidor local
Valla a
www.sunbeam.com
Llame a servicio al consumidor al 1-888-264-9669
SCM630_631C-UM_11ESM1.indd 2 5/9/11 3:14 PM

Transcripción de documentos

TROUBLESHOOTING F R E Q U E N T LY A S K E D Q U E S T I O N S TROUBLESHOOTING FREQUENTLY ASKED QUESTIONS TROUBLE • Unit does not turn on. PROBABLE CAUSE * Not plugged in. * Outlet not functioning. SOLUTION • Mist output minimal to none. * Cool mist is invisible. 4 Operate in High setting. * The filter has not absorbed water. 4 Wait 30 minutes for filter to absorb water. • Filter turns brown. * The filter has absorbed minerals. 4 Replace your filter (HWF100 / SF235) by calling 1-888 -264-9669, or visiting www.sunbeam.com. • FilterCheck® is not working. * Takes 60 minutes to register. 4 Allow the humidifier to run continuously for 60 minutes for the FilterCheck® Indicator to reflect the filter condition. • Humidifier continuously displays 25%. * Humidity at the humidifier is at or below 25%. • Humidifier continuously displays 80%. * Humidity at the humidifier is at or above 80%. 4 Plug in unit. 4 Have outlet replaced by a licensed electrician. Question Answer • What are the variables that affect run time? The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as: ✔ Air exchange in the room where the humidifier is placed. ✔ Room construction of the room where the humidifier is placed. ✔ Temperature of the room where the humidifier is placed. ✔ Humidity levels in the room where the humidifier is placed. ✔ Movement of occupants and the opening and closing of doors in the room where the humidifier is placed. ✔ Home furnishings in the room where the humidifier is placed. 4 Continue to operate humidifier to raise the room humidity. • How do I remove film on water tank? ✔ See Daily Maintenance instructions. Regular cleaning is recommended. 4 Stop operating the humidifier if the humidity level is too high. • How can I extend the run time? ✔ Run your unit on the lowest setting. ✔ If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time. ✔ Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time. If you have any questions regarding your product or would like to learn more about other Sunbeam® products, please contact our Consumer Service Department at 1-888-264-9669 or visit our website at www.sunbeam.com. WA R R A N T Y I N F O R M AT I O N 1 Y E A R L I M I T E D WA R R A N T Y Sunbeam Products, Inc. doing business as Jarden Consumer Solutions or if in Canada, Sunbeam Corporation (Canada) Limited doing business as Jarden Consumer Solutions (collectively “JCS”) warrants that for a period of one year from the date of purchase, this product will be free from defects in material and workmanship. JCS, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty. Do NOT attempt to repair or adjust any electrical or mechanical functions on this product. Doing so will void this warranty. This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. JCS dealers, service centers, or retail stores selling JCS products do not have the right to alter, modify or any way change the terms and conditions of this warranty. This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than JCS or an authorized JCS service center. Further, the warranty does not cover: Acts of God, such as fire, flood, hurricanes and tornadoes. WA R R A N T Y I N F O R M AT I O N SCM630 SCM631 TRUSTED FOR OVER 100 YEARS Cool Mist Tower In the U.S.A., this warranty is offered by Sunbeam Products, Inc. doing business as Jarden Consumer Solutions located in Boca Raton, Florida 33431. In Canada, this warranty is offered by Sunbeam Corporation (Canada) Limited doing business as Jarden Consumer Solutions, located at 20 B Hereford Street, Brampton, Ontario L6Y 0M1. If you have any other problem or claim in connection with this product, please write our Consumer Service Department. PLEASE DO NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE. Humidifier What are the limits on JCS’s Liability? JCS shall not be liable for any incidental or consequential damages caused by the breach of any express, implied or statutory warranty or condition. Except to the extent prohibited by applicable law, any implied warranty or condition of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. JCS disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise. JCS shall not be liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use the product including incidental, special, consequential or similar damages or loss of profits, or for any breach of contract, fundamental or otherwise, or for any claim brought against purchaser by any other party. Some provinces, states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from province to province, state to state or jurisdiction to jurisdiction. How to Obtain Warranty Service In the U.S.A. If you have any question regarding this warranty or would like to obtain warranty service, please call 1-888-264-9669 and a convenient service center address will be provided to you. In Canada If you have any question regarding this warranty or would like to obtain warranty service, please call 1-888-264-9669 and a convenient service center address will be provided to you. FILTER# : HWF100 / SF235 FILTER TYPE : WICK Instruction Leaflet © 2011 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions. All Rights Reserved. Distributed by Sunbeam Products, Inc. doing business as Jarden Consumer Solutions, Boca Raton, Florida 33431. PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS Printed In China DIAGNÓSTICO DE PROBLEMAS P R E G U N TA S F R E C U E N T E S INFORMACION DE LA GARANTIA DIAGNÓSTICO DE PROBLEMAS PREGUNTAS FRECUENTES G A R A N T Í A L I M I TA D A D E 1 A Ñ O Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions, o en Canadá, Sunbeam Corporation (Canada) Limited operando bajo el nombre de Jarden Consumer Solutions, (en forma conjunta, “JCS”), garantiza que por un período de uno año a partir de la fecha de compra, este producto estará libre de defectos de materiales y mano de obra. JCS, a su elección, reparará o reemplazará este producto o cualquier componente del mismo que presente defectos durante el período de garantía. El reemplazo se realizará por un producto o componente nuevo o reparado. Si el producto ya no estuviera disponible, se lo reemplazará por un producto similar de valor igual o superior. Ésta es su garantía exclusiva. No intente reparar o ajustar ninguna función eléctrica o mecánica de este producto. Al hacerlo elimínará ésta garantía. La garantía es válida para el comprador minorista original a partir de la fecha de compra inicial y la misma no es transferible. Conserve el recibo de compra original. Para solicitar servicio en garantía se requiere presentar un recibo de compra. Los agentes y centros de servicio de JCS o las tiendas minoristas que venden productos de JCS no tienen derecho a alterar, modificar ni cambiar de ningún otro modo los términos y las condiciones de esta garantía. Esta garantía no cubre el desgaste normal de las piezas ni los daños que se produzcan como resultado de uso negligente o mal uso del producto, uso de voltaje incorrecto o corriente inapropiada, uso contrario a las instrucciones operativas, y desarme, reparación o alteración por parte de un tercero ajeno a JCS o a un Centro de Servicio autorizado por JCS. Asimismo, la garantía no cubre actos fortuitos tales como incendios, inundaciones, huracanes y tornados. ¿Cuál es el límite de responsabilidad de JCS? JCS no será responsable de daños incidentales o emergentes causados por el incumplimiento de alguna garantía o condición expresa, implícita o legal. Excepto en la medida en que lo prohíba la ley aplicable, cualquier garantía o condición implícita de comerciabilidad o aptitud para un fin determinado se limita, en cuanto a su duración, al plazo de la garantía antes mencionada. JCS queda exenta de toda otra garantías, condiciones o manifestaciones, expresa, implícita, legal o de cualquier otra naturaleza. JCS no será responsable de ningún tipo de daño que resulte de la compra, uso o mal uso del producto, o por la imposibilidad de usar el producto, incluidos los daños incidentales, especiales, emergentes o similares, o la pérdida de ganancias, ni de ningún incumplimiento contractual, sea de una obligación esencial o de otra naturaleza, ni de ningún reclamo iniciado contra el comprador por un tercero. Algunas provincias, estados o jurisdicciones no permiten la exclusión o limitación de los daños incidentales o emergentes ni las limitaciones a la duración de las garantías implícitas, de modo que es posible que la exclusión o las limitaciones antes mencionadas no se apliquen en su caso. Esta garantía le otorga derechos legales específicos y es posible que usted tenga otros derechos que varían de un estado, provincia o jurisdicción a otro. PROBLEMA POSIBLE CAUSA • La unidad no se enciende. * No está enchufada. * El omacorriente no funciona. SOLUCIÓN 4 Enchúfela. 4 Haga reemplazar el tomacorriente por un electricista matriculado. PREGUNTAS • WCuáles son las variables que afectan el tiempo de funcionamiento? El tiempo de funcionamiento estimado de este humidificador está basado en las condiciones ambientales promedio. El tiempo de funcionamiento actual de su humidificador depende de varios factores tales como : ✔ El intercambio de aire en el cuarto donde se encuentra el humidificador. ✔ La estructura del cuarto donde se encuentra el humidificador. ✔ La temperatura del cuarto donde se encuentra el humidificador. ✔ Los niveles de humedad en el cuarto donde se encuentra el humidificador. ✔ La actividad de los ocupantes y la secuencia en que se abren y cierran las puertas del cuarto donde se encuentra el humidificador. ✔ El número de muebles presentes en el cuarto donde se encuentra el humidificador. • Cómo quito la película del tanque de agua? ✔ Consulte las instrucciones diarias de mantenimiento. Se recomienda una limpieza regular. 4 Funcionamiento en configuración High (alta). • Salida de vapor mínima o * La niebla fría es invisible. * El filtro no ha absorbido el agua. 4 Espere 30 minutos para que el filtro absorba el agua. nula. • El filtro se pone marrón. * El filtro ha absorbido minerales. 4 Reemplace su filtro (HWF100 / SF235) llamando al 1-888-264-9669, o visite www.sunbeam.com. • El FilterCheck® no está funcionando. * Demora 60 minutos registrarse. 4 Permita que el humidificador funcione continuamente durante 60 minutos para que el indicador del FilterCheck® refleje el estado del filtro. • El humidificador muestra constantemente un 25%. * La humedad del 4 Permita que su humidificador siga funcionando humidificador está en un para aumentar la humedad de la habitación. nivel inferior o igual al 25%. • El humidificador muestra constantemente un 80%. * La humedad del humidificador 4 Detenga el funcionamiento del humidificador si el se encuentra en 80% o más. nivel de humedad es muy alto. RESPUESTAS • Cómo puedo extender el tiempo de ✔ Haga funcionar la unidad en el modo más bajo. funcionamiento? ✔ Si su unidad tiene electrónicos, ajústela al nivel de humedad deseado. La unidad se encenderá y apagará, extendiendo el tiempo de funcionamiento. ✔ Llene el tanque al máximo, colóquelo en la base, deje que el agua se vacíe en la base hasta que deje de burbujear, luego llene nuevamente el tanque al máximo. Esto asegura una capacidad máxima de agua que extenderá el tiempo de funcionamiento. Si tiene preguntas relacionadas con este producto o si está interesado en conocer otros productos Sunbeam®, póngase en contacto con nuestro Departamento de Servicio al Cliente: llame al 1 (888) 264-9669 o visite nuestro sitio web www.sunbeam.com. INFORMACION DE LA GARANTIA En los Estados Unidos, esta garantía es ofrecida por Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions, Boca Ratón, Florida 33431. En Canadá, esta garantía es ofrecida por Sunbeam Corporation (Canada) Limited operando bajo el nombre de Jarden Consumer Solutions, 20 B Hereford Street, Brampton, Ontario L6Y 0M1. Si usted tiene otro problema o reclamo en conexión con este producto, por favor escriba al Departamento de Servicio al Consumidor. POR FAVOR NO DEVUELVA ESTE PRODUCTO A NINGUNA DE ESTAS DIRECCIONES NI AL LUGAR DE COMPRA. Cómo solicitar el servicio en garantía En los Estados Unidos Si tiene alguna pregunta sobre esta garantía o desea recibir servicio de garantía, llame al 1-888-264-9669 y podrá obtener la dirección del centro de servicio que le resulte más conveniente. En Canadá Si tiene alguna pregunta sobre esta garantía o desea recibir servicio de garantía, llame al 1-888-264-9669 y podrá obtener la dirección del centro de servicio que le resulte más conveniente. SCM630 SCM631 100 AÑOS Torre De Niebla Fría Humidificador FILTRO# : HWF100 / SF235 FILTRO TIPO : MECHAS © 2011 Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions. Todos los derechos reservados. Distribuido por Sunbeam Products, Inc. operando bajo el nombre de Jarden Consumer Solutions, Boca Raton, Florida 33431. 141068/9100030007181 GCDS-SUN20400-JC SCM630_631C-UM_11ESM1.indd 1 CONFIANZA DESDE HACE SCM630/631UM11ESM1 Impreso en China D Folleto de instrucciones LEA Y CONSERVE ESTAS IMPORTANTES INSTRUCCIONES 5/9/11 3:14 PM P L E A S E R E A D A N D S AV E T H E S E I M P O R TA N T S A F E T Y I N S T R U C T I O N S When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before using the appliance. 2. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet. 3. Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers. 4. DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. DO locate your humidifier on an inside wall near an electrical outlet. The humidifier should be at least 4 inches (10 cm) away from the wall for best results. 5. NEVER place humidifier in an area where it is accessible to children. NEVER use humidifier in a closed room, particularly where a child may be sleeping, resting, or playing (a closed room may result in excessive humidity). 6. WARNING: Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet. Failure to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord. 7. Never place anything over moisture outlet when the unit is running. 8. NEVER drop or insert any object into any openings. 9. DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair. 10. Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by the manufacturer may cause hazards. 11. DO NOT use outdoors. 12. Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture. 13. DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wallpaper. 14. Humidifier should be unplugged when not in use. 15. NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit. 16. This humidifier requires daily and weekly maintenance to operate appropriately. Refer to daily and weekly cleaning procedures. Use only cleaners and additives recommended by the manufacturer. 17. NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier. 18. Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF. 19. Do not use humidifier in an area where humidity level is in excess of 50%. Use a hygrometer, available at your local retailer or through the manufacturer, to measure the humidity. 20. DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only. 21. Never place housing under water flow or immerse in liquids. 22. Do not plug in the cord with wet hands: electric shock could result. 23. Do not pour water in any openings other than the water tank. 24. To prevent damage to surfaces, do not place humidifier under overhanging surfaces. 25. NEVER operate unit without water in the tank. THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS SAFETY FEATURE IN ANY WAY. L E A Y C O N S E R V E E S TA S I M P O R TA N T E S INSTRUCCIONES DE SEGURIDAD Debe tomar precauciones básicas de seguridad siempre que utilice artefactos eléctricos para reducir el riesgo de incendio, descarga eléctrica y daños personales, incluyendo lo siguiente: 1. Lea completamente las instrucciones antes de utilizar el artefacto. 2. Para evitar incendio o descarga eléctrica, enchufe el artefacto directamente en un tomacorriente de 120V CA. 3. Mantenga el cable fuera de las zonas de mucho tráfico. Para evitar incendios, NUNCA coloque el cable debajo de alfombrillas o cerca de salidas de calefacción. 4. NO coloque el humidificador cerca de fuentes de calor como estufas, radiadores y calefactores. NO coloque el humidificador contra una pared interna cerca de un tomacorriente. El humidificador debe estar a por lo menos 4" de la pared para obtener el mejor resultado. 5. NUNCA coloque el humidificador en una zona accesible para los niños. NUNCA use el humidificador en un cuarto cerrado, especialmente donde pueda haber un niño durmiendo, descansando, o jugando (un cuarto cerrado puede resultar en excesiva humedad). 6. ADVERTENCIA: No intente llenar nuevamente el humidificador sin antes desenchufarlo del tomacorriente. El no tener en cuenta esta advertencia puede causar daños personales. Asegúrese de desenchufar la unidad tirando del enchufe y no del cable. 7. Nunca coloque algo sobre la salida de humedad cuando la unidad esté funcionando. 8. NUNCA inserte ningún objeto en una de las ranuras. 9. NO utilice ningún artefacto si el cable o el enchufe están dañados, luego de una falla, o si se ha caído o ha sufrido cualquier tipo de daño. Devuelva el artefacto al fabricante para su inspección, ajuste eléctrico o mecánico, o reparación. 10. Utilice el artefacto únicamente para el propósito hogareño indicado en este manual. Cualquier uso distinto al recomendado por el fabricante puede causar incendio, descarga eléctrica, o daños personales. El uso de accesorios no recomendados o que no sean vendidos por el fabricante puede ser peligroso. 11. NO utilizar en el exterior. 12. Siempre coloque el humidificador en una superficie firme, plana y nivelada. Se recomienda el colocar una alfombrilla o bandeja resistente al agua debajo del humidificador. NUNCA lo coloque sobre un tapete o una alfombra, o en un piso que pueda dañarse con el agua o la humedad. 13. NO haga que la salida de humedad apunte directamente a la pared. La humedad puede causar daños, especialmente al empapelado. 14. Se debe desenchufar el humidificador cuando no se usa. 15. NUNCA incline, mueva o intente vaciar la unidad mientras esté funcionando. Apague y desenchufe la unidad antes de quitar el tanque de agua y moverla. 16. Este humidificador requiere mantenimiento diario y semanal para funcionar correctamente. Refiérase a los procedimientos de limpieza diarios y semanales. Use únicamente limpiadores y aditivos recomendados por el fabricante. 17. NUNCA use detergentes, gasolina, limpiavidrios, limpiador de muebles, diluyente de pintura u otro solvente hogareño para limpiar ninguna parte del humidificador. 18. La humedad excesiva en un cuarto puede causar condensación de agua en las ventanas y en algunos muebles. Si sucede esto, apague el humidificador. 19. No use el humidificador en un área donde el nivel de humedad es mayor al 50%. Use un Higrómetro, disponible en su tienda local o a través del fabricante, para medir la humedad. 20. NO intente reparar o ajustar ninguna función eléctrica o mecánica de esta unidad. El hacerlo invalidará la garantía. La unidad no contiene partes reparables por el usuario. Toda reparación debe ser realizada únicamente por personal calificado. 21. Nunca coloque el gabinete debajo de la canilla o lo sumerja en líquidos. 22. No enchufe el cable con las manos húmedas. Puede ocasionarle una descarga eléctrica. ESTE PRODUCTO TIENE UN ENCHUFE POLARIZADO (una hoja es más ancha que la otra). A fin de disminuir el riesgo de descarga eléctrica, este enchufe está diseñado para insertarse en un tomacorriente polarizado en un solo sentido. Si el enchufe no entra completamente en el tomacorriente, inviértalo. Si aun así no entra, llame a un electricista calificado para instalar un tomacorriente apropiado. NO MODIFIQUE EL ENCHUFE NI ANULE ESTA FUNCION DE SEGURIDAD DE NINGUNA MANERA. SCM630_631C-UM_11ESM1.indd 2 F E AT U R E S - O P E R AT I O N S 26. Do not move unit after it has been used until unit cools completely. 27. Use both hands when carrying full tank of water. PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS PRE-OPERATING INSTRUCTIONS 1. Be sure the humidifier is switched to OFF and the unit is disconnected from the electrical outlet. 2. Select a location for your humidifier, on a flat surface, about 4 inches (10 cm) away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by too much moisture or water. Place on a moisture resistant surface. FILLING THE WATER TANK 1. Remove the tank from the housing of the humidifier by grabbing the handle of the tank and pulling forward. Lift NOTE: This is an electrical appliance and requires attention the tank out of the housing and bring to the faucet. Turn when in use. the tank upside down and twist off the tank cap by NOTE: If moisture forms on the walls or windows of the turning counter clockwise. Fill tank with cool, fresh tap room, turn off the humidifier. The room already has plenty of water. DO NOT fill with warm water as this may cause humidity and additional moisture may cause damage. leaking. Replace the cap on tank FIRMLY. 2. When full, carry the tank to the humidifier and place it NOTE: DO NOT block air inlet or outlet. into the housing. There is a locating tab located on the Cord and Plug Installation Safety Instructions: tank base for easy guidance. The tank holds 1.2 gallons The length of cord used on this appliance was selected to reduce of water. The tank will immediately begin to empty into the hazards of becoming tangled in, or tripping over a longer the base. cord. If a longer cord is necessary an approved extension cord 3. Plug the power cord into a 120V AC electrical outlet. may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier (refer to the rating information placed on the humidifier). Care must be OPERATING INSTRUCTIONS taken to arrange the extension cord so that it will not drape Power Button over the countertop or tabletop where it can be pulled on by 1. Press the Power Button to turn the humidifier on, the children or accidentally tripped over. LCD Display shows the Room humidity level. NOTE: The display range is 25% - 80%. If your room HOW COOL MIST WORKS humidity level falls below 25%, the unit will display 25. If your room humidity level rises above 80%, the unit Your Sunbeam® Cool Mist humidifier draws dry air through will display 80. the rear air intake grill area. This air is then passed through a moisture–laden wick filter, which retains the minerals and 2. The default is running the humidifier at the HIGH manual setting. deposits in the water. The resulting moist air is directed back 3. Press the button again for the LOW manual setting. Once into the room from the top air grill. selected, the Setting Indicators will illuminate to NOTE: This humidification system provides a cool, invisible indicate which setting is activated. moisture output. It is normal not to see the mist. 4. Press the button again will stop the unit. To shut off the NOTE: A humidity level below 20% can be unhealthy and humidifier at any time of operation, press and hold the uncomfortable. The recommended humidity level is between button for two seconds, or keep pressing the button until 40%-50%. the display goes off. CONSUMER SAFETY INFORMATION NOTES: • High setting will produce the maximum moisture level and Low setting will produce the longest run time and Your humidifier is equipped with a digital humidistat that quieter performance. allows you to set your humidifier to your desired comfort level. To preset a precise comfort level, turn the Toggle Switch • The 9 holes below control panel are part of the to adjust the humidity level ranging from 30% to 60% or humidistat sensor. “ ” setting for constant humidity. Humidity will increase Tank Empty or decrease in increments of 5%. The LCD Display will show the selected humidity level for 3 seconds and then change Once the tank is empty, turn off your humidifier and unplug back to show the room humidity. The Set humidity level will it from the electrical outlet. Before refilling, empty any illuminate on top left of the LCD Display. When the room residual water from the base and the tank (follow the daily humidity level rises above the set humidity, the humidifier will maintenance instructions). Then follow the Filling Instructions stop. When the room humidity level drops below the set humidity, to refill the tank and put back into the humidifier to begin the humidifier will turn on automatically to maintain the preset operation. humidity level. Timer NOTE: To shut the humidifier off at any setting, press the Power Button ( ). The humidistat has memory. This means Your humidifier is equipped with 24-Hour Auto Shut-off Timer that when you turn the unit back on, it will be at the last feature. This allows you to program your humidifier to shut humidity setting before the humidifier is turned off. However, off automatically after running a defined time interval. if the humidifier is unplugged, the digital humidistat will no 1. Press the Timer Button ( ) once. The "0" Hr icon will longer remember the previous humidity setting. You will need begin to blink. to reset the digital humidistat if the humidifier is unplugged. 2. Turn the toggle switch to adjust from 0 to 24 to select WARNING: DO NOT move the humidifier with water in your desired time interval for the humidifier to shut-off the tank or the humidifier base. The moving action of the automatically. water may activate the water tank’s release nozzle and 3. The selected hour will appear on the LCD Display for 3 overfill the humidifier base. This may cause the seconds and then the LCD Display will return to show the humidifier to function intermittently, or stop emitting mist. Should this occurs, simply remove the excess water Figure 2 from the humidifier base. Digital Humidistat Control Figure 1 LEA Y CONSERVE ESTAS IMPORTANTES INSTRUCCIONES DE SEGURIDAD INFORMACIÓN DE SEGURIDAD PARA EL CONSUMIDOR NOTA: Este es un artefacto eléctrico y requiere ser usado con cuidado. NOTA: Si se acumula humedad en las paredes o ventanas del cuarto, apague el humidificador. El cuarto ya tiene demasiada humedad y la humedad adicional puede causar daños. NOTA: NO bloquee la entrada o salida de aire. Instrucciones de Seguridad en la Instalación del Cable y el Enchufe : La longitud del cable de este artefacto fue seleccionada para reducir el riesgo de enredarse o tropezarse con un cable más largo. Si necesita usar un cable más largo, puede utilizar un cable de extensión aprobado. La capacidad eléctrica del cable de extensión debe ser igual o mayor que la capacidad del humidificador (consulte la información sobre clasificación que se encuentra en el humidificador). No debe permitir que el cable de extensión cuelgue de la mesada o mesa de tal forma que pueda ser jalado por niños o causar que alguien se tropiece. dirigido nuevamente al ambiente por la rejilla superior. NOTA: Este sistema de humidificación proporciona una salida de humedad fría e invisible. Es normal que no se vea el vapor. NOTA: Un nivel de humedad menor al 20% puede ser nocivo e incómodo. El nivel de humedad recomendado es entre el 40% y el 50%. INSTRUCCIONES PREVIAS AL USO 1. Asegúrese de que el humidificador esté en OFF y desenchúfelo del tomacorriente. 2. Elija un lugar para su humidificador, en una superficie plana, aproximadamente a 4 pulgadas de distancia de la pared. NO coloque el humidificador sobre un piso pulido o cerca de algún mueble, ya que lo puede dañar por el exceso de humedad o agua. Colóquelo sobre una superficie resistente a la humedad. COMO LLENAR EL TANQUE DE AGUA 1. Retire el tanque de la carcasa del humidificador agarrando la manija del tanque y tirando hacia adelante. Levante el tanque fuera de la carcasa y llévelo a la canilla. De vuelta el tanque y desenrosque la tapa del tanque girando en sentido contrario a las agujas del reloj. Llene el tanque con agua fría del grifo. NO llene con agua caliente ya que puede producir una pérdida. Vuelva a colocar la tapa del tanque CON FIRMEZA. 2. Cuando esté lleno, lleve el tanque hasta el humidificador y colóquelo dentro de la carcasa. Hay una etiqueta ubicada en la base del tanque para fácil orientación. El tanque tiene una capacidad de 5 litros de agua. El tanque comenzará a vaciarse inmediatamente en la base. 3. Enchufe el cable de corriente en un tomacorriente de 120 voltios AC. INSTRUCCIONES DE USO Botón Encendido 1. Presione el botón de encendido (power) del humidificador, el visor LCD indicará el nivel de humedad del ambiente. COMO FUNCIONA EL VAPOR FRÍO NOTA: El rango del visor oscila entre el 25% y el 80%. Si el nivel de humedad del ambiente se encuentra por Su humidificador Sunbeam® de Vapor Frío succiona aire seco a debajo del 25%, la unidad indicará 25. Si el nivel de través de la rejilla de entrada de aire. Luego, el aire pasa por 6 humedad del ambiente supera el 80%, la unidad filtros de mecha cargados de humedad, los que retienen los indicará 80. minerales y depósitos del agua. El aire húmedo resultante es F C E A. B. C. D. E. F. CARACTERISTICA - FUNCIONAMIENTO 23. No coloque agua en ninguna abertura que no sea el tanque de agua. 24. Para prevenir el daño a las superficies, no coloque el humidificador debajo de ninguna superficie que sobresalga por encima del mismo. 25. NUNCA haga funcionar la unidad sin agua en el tanque. 26. Una vez utilizada la unidad, no la mueva hasta que se haya enfriado completamente. 27. Use las dos manos cuando cargue el tanque de agua. R E P L A C I N G T H E F I LT E R S CLEANING / MAINTENANCE F E AT U R E S - O P E R AT I O N S B Tank Tank Handle Base Humidifier Housing A Control Panel ® FilterCheck Indicator B D D A C A. Power Button B. Toggle Switch C. LCD Display D. Timer Button CARACTERISTICA - FUNCIONAMIENTO 2. La configuración predeterminada del humidificador opera en manual alta (HIGH). 3. Presione nuevamente el botón para establecer la configuración manual baja (LOW). Una vez seleccionada, los Indicadores de configuración se iluminarán para indicar qué configuración fue activada. 4. Presione nuevamente el botón para detener la unidad. Para apagar el humidificador en cualquier instancia de la operación, presione y mantenga presionado el botón por dos segundos, o hasta que el visor se apague. Control digital del medidor de humedad El humidificador está equipado con un medidor de humedad digital que le permite configurar su humidificador al nivel deseado. Para predeterminar un nivel específico que resulte cómodo, gire el Interruptor de conmutación para ajustar un nivel de humedad del 30% al 60% o “ ” (constante) para establecer una humedad constante. La humedad aumentará o disminuirá en incrementos del 5%. El visor LCD mostrará el nivel de humedad seleccionado durante 3 segundos y luego volverá a mostrar la temperatura ambiente. El nivel de humedad especificado aparecerá iluminado en el extremo superior izquierdo del visor LCD. Cuando el nivel de humedad del ambiente ascienda por encima de la humedad establecida, el humidificador se detendrá. Cuando la humedad del ambiente sea menor a la establecida, el humidificador se encenderá de manera automática para mantener el nivel de humedad configurado previamente. NOTA: Para apagar el humidificador en cualquier configuración, presione el Botón Encendido ( ). El medidor de humedad tiene memoria. Significa que cuando lo vuelva a Figura 1 Tanque vacío Una vez que el tanque se encuentre vacío, apague el humidificador y desconéctelo del tomacorrientes. Antes de llenarlo nuevamente, vacíe el tanque y la base de todo resto de agua (siga las instrucciones de mantenimiento diario). A continuación, siga las Instrucciones de llenado para rellenar Figura 2 C F E Tanque B Manija Base Cubierta del humidificador A E. Panel de control F. Indicador FilterCheck® A. B. C. D. encender, la unidad tendrá la última configuración de humedad que tenía antes que se apagara el humidificador. Sin embargo, si el humidificador está desenchufado, el medidor de humedad digital no recordará la configuración de humedad previa. Deberá reiniciar el medidor de humedad digital si el humidificador está desenchufado. ADVERTENCIA: NO MUEVA el humidificador cuando tenga agua en el tanque o en la base. La acción de movimiento podría activar la boquilla de descarga del tanque de agua y saturar la base del humidificador. Si sucediera, el humidificador funcionaría intermitentemente y dejaría de emitir vapor. En este caso, simplemente elimine el exceso de agua de la base del humidificador. NOTAS: • La posición alta producirá el máximo nivel de humedad y una posición baja ofrecerá el mayor tiempo de uso y un funcionamiento más silencioso. • Los 9 orificios en la parte inferior de la panel de control constituyen el sensor del medidor de humedad. B D D C A A. Botón de encendido (power) B. Interruptor de conmutación C. Visor LCD D. Botón del temporizador (timer) Room Humidity. The Timer icon ( ) will appear on the LCD Display to indicate that the selected timer. 4. When timer is set, you may check the remaining time while humidifier is still in operation. Press the Timer Button and the remaining time (e.g., 7 Hr) will illuminate on the LCD Display for 3 seconds. 5. To cancel the Timer feature, press the Timer Button ( ). The remaining time will appear on the screen. Turn the toggle switch to 0 hours. The Timer will then be cancelled. REPLACING THE FILTERS Through normal use, waterborne minerals and sediment become trapped in the wick filter. The harder your water, the greater the amount of minerals in the water, and the more often you will need to change your filter. You will be able to monitor the life of the filter in your humidifier by checking the FilterCheck® Indicator. NOTE: After 60 minutes of use, FilterCheck® Indicator will move and indicate your filter condition. Figure 3 A brand new filter will register in the section reading GOOD filter. After frequent use of your humidifier, the FilterCheck® Indicator will let you know when the filters need to be changed, see Figure 3. When the needle is in the CHANGE section, this means the proper amount of moisture is not getting into your air due to the excessive minerals and sediment that have become trapped on your filters. At this point, you should replace your filter. It is important to change your filter as indicated to obtain stated performance level. To replace the filter, follow the steps below: 1. Turn the unit off and disconnect from the electrical outlet. 2. Remove the tank from the housing. 3. Unlock the housing from the base by turning the lock knob to the unlocked position. 4. Lift the housing straight up and place to the side. 5. Unlock the wick holder from the base by turning the lock knob to the unlocked position. 6. Remove the wicks from the wick holder. 7. Follow the weekly cleaning instructions. 8. Insert new filters into the wick holder and lock the wick holder back onto the base. 9. Replace the housing onto the base and lock it into place. 10. Fill the tank and place back into housing. 11. Repeat Operating Instructions. It will take about 30 minutes for the humidifier to reach maximum output. NOTE: You can purchase replacement filters (model HWF100 / SF235) at a local retailer, by calling 1-888-264-9669, or by visiting www.sunbeam.com. It is recommended that a replacement filter is purchased for uninterrupted use. CLEANING AND MAINTENANCE INSTRUCTIONS Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use. In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the water tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up. the tank with cool tap water as instruction earlier in the filling instructiosn. Do not overfill. 6. Follow Operating Instructions. NOTE: The Tray is dishwasher safe (TOP RACK ONLY) for easy cleaning. Weekly Maintenance To Remove Scale: 1. Repeat steps 1-4 above. 2. Clean the base by partially filling the base with one 8-oz cups of undiluted white vinegar, or by using Cleanse Clean® solution (Model S1710) by the manufacturer. Leave this solution in the base for 20 minutes, while cleaning all the interior surfaces with a soft brush. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar. 3. Rinse with clean warm water to remove the cleaning solution before disinfecting the tank. To Disinfect Humidifier Base and Tank: 1. Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Carefully empty the tank after 20 minutes, and rinse with warm water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel. 4. Place filter back into tank and refill the water tank as directed in Operating Instructions, and turn the unit on. STORAGE INSTRUCTIONS When not using your humidifier for an extended period of time: 1. Dispose of the filters. DO NOT leave in unit. 2. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season. 3. Place the humidifier in the original carton and store in a cool, dry place. 4. Order your replacement filter for next year’s use. REPLACEMENT ACCESSORIES To order the replacement accessories you can do any of the following: • Visit your local retailer • Go to www.sunbeam.com • Call Consumer Service at 1-888-264-9669 Daily Maintenance 1. Be sure the unit is OFF and is disconnected from the electrical outlet. 2. Remove the housing and the tank from the humidifier and place in sink or tub. 3. Carry the base of the unit to the sink, remove the wick, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean, and dry with a clean cloth or paper towel. 4. Drain the water from the tank into the sink and rinse tank thoroughly. Wipe clean, and dry with a clean cloth or paper towel. 5. Put filters back into wick holder making sure the rivet attaches to the holder. Lock the wick holder back into place. Replace the housing and lock it into place. Refill R E E M P L A Z O D E L O S F I LT R O S INSTRUCCIONES DE LIMPIEZA Y MANTENIMIENTO el tanque y volver a colocarlo dentro del humidificador STORAGE INSTRUCTIONS REPLACEMENT ACCESSORIES frecuencia su humidificador, el indicador FilterCheck® le avisará cuando tiene que cambiar su filtros, observe la Figura para su funcionamiento. 3. Temporizador Cuando la aguja esté en el área CAMBIAR, significa que la unidad no está emitiendo la humedad necesaria debido a la Su humidificador está equipado con la función de temporizador de apagado automático a las 24 horas. Permite excesiva cantidad de minerales y sedimentos que se encuentran retenidos en el filtros. Ahora es cuando debe programar el humidificador para que se apague de manera reemplazar el filtro. Para obtener un mejor rendimiento, es automática luegode un plazo determinado. importante cambiar su filtro según se indica. 1. Presione el Botón Temporizador ( ) una vez. El icono Para reemplazar el filtro, siga los siguientes pasos. de hora “0” empezará a titilar. 1. Apague la unidad y desenchúfela del tomacorriente. 2. Gire el interruptor de conmutación para ajustar de 0 a 2. Retire el depósito de la caja. 24 el intervalo de tiempo que desee seleccionar para 3. Desbloquee la caja de la base girando la perilla de que el humidificador se apague automáticamente. bloqueo hasta la posición de desbloqueo. 3. La hora seleccionada aparecerá en el Visor LCD durante 4. Levante la caja en línea recta y colóquela a un costado. 3 segundos y luego el Visor LCD volverá a mostrar la 5. Desbloquee el soporte de mechas de la base girando la Humedad ambiente. El icono Temporizador ( ) perilla de bloqueo hasta la posición de desbloqueo. aparecerá en el visor LCD para indicar el temporizador 6. Retire las mechas del soporte de mechas. seleccionado. 7. Siga las instrucciones para la limpieza semanal. 4. Cuando el temporizador esté configurado, usted puede 8. Inserte los filtros limpios en el soporte de mechas y verificar el tiempo restante mientras el humidificador bloquéelo nuevamente en la base. todavía está en funcionamiento. Presione el Botón 9. Vuelva a colocar la caja sobre la base y bloquéela en su Temporizador y el tiempo restante (por ejemplo, 7 horas) lugar. se encenderá en el visor LCD durante 3 segundos. 10. Llene el depósito y colóquelo nuevamente en la caja. 5. Para cancelar la función del Temporizador, presione el 11. Repita las Instrucciones de Funcionamiento. botón Temporizador ( ). El tiempo restante Tomará aproximadamente 30 minutos para que el aparecerá en la pantalla. Gire la Interruptor de humidificador alcance su potencia máxima. conmutación hasta 0 horas. Entonces se cancelará el NOTA: Puede comprar repuestos de filtros (modelo HWF100 / Temporizador. SF235) en una tienda local, llamando al 1-888-264-9669, ó visitando www.sunbeam.com. Se recomienda que compre un filtro REEMPLAZO DE LOS FILTROS de repuesto para no interrumpir el funcionamiento de la unidad. Durante el uso normal de la unidad, los minerales y sedimentos arrastrados por el agua quedan retenidos en el INSTRUCCIONES DE LIMPIEZA Y filtro de mecha. Mientras más dura sea el agua, mayor será el número de minerales que contenga, mientras mayor sea el MANTENIMIENTO Los humidificadores proveen confort agregando humedad al número de minerales en el agua, mayor será la frecuencia aire seco de los ambientes interiores calefaccionados. Para en que tenga que cambiar el filtro. Podrá monitorear la vida del filtro de su humidificador con el beneficiarse al máximo de los humidificadores y evitar su mal uso, siga todas las instrucciones cuidadosamente. Tenga indicador FilterCheck®. en cuenta que éste es un artefacto eléctrico que requiere NOTA: Trás 60 minutos de uso, el indicador Figura 3 atención cuando esté en uso. ® FilterCheck se moverá e indicará la condición Además, si no se siguen las recomendaciones para el cuidado y de sus filtro. mantenimiento, crecerán microorganismos en el agua dentro de Un filtro completamente nuevo se registrará los tanques. Se deben ejecutar rutinariamente los procedimientos en la sección denominada Filtro BUENO. de limpieza que se indican a continuación para asegurar el Después de haber usado con bastante I N S T R U C C I O N E S PA R A G U A R D A R ACCESORIOS DE REPUESTO funcionamiento adecuado y eficiente del humidificador que son esenciales para el rendimiento óptimo constante de la unidad y para evitar la formación de algas y bacterias. Mantenimiento diario 1. Asegúrese de apagar y desenchufar la unidad del tomacorriente. 2. Desmonte el casco y los tanques del humidificador y colóquelos en el fregadero o en la tina. 3. Lleve la base de la unidad al fregadero o a la tina, quítele el filtro de mecha, coloque la base en el fregadero, drene el agua remanente, enjeague completamente para remover cualquier sedimento o suciedad, limpie frotando con un paño y seque con una toalla de tela o papel. 4. Drene el agua de los tanques en el fregadero y enjuáguelos completamente. Límpielos frotando con un paño y séquelos con una toalla de tela o de papel. 5. Vuelva a colocar los filtros en el soporte de la mecha asegúrese de que el remache esté sujeto al soporte. Sujete el soporte de la mecha en su lugar. Vuelva a poner la carcasa en su lugar. Vuelva a llenar el tanque con agua fría como se detalla anteriormente en las instrucciones de llenado. No lo llene de más. 6. Siga las instrucciones de operación. NOTA: La bandeja es apta para lavavajillas (SOLO EN EL ESTANTE SUPERIOR) para fácil lavado. Mantenimiento semanal Para extraer el sarro : 1. Repita los pasos 1 al 4 anteriores. 2. Limpie la base llenándola parcialmente con una taza de 250 ml (8 oz.) de vinagre blanco sin diluir o con Cleanse Clean® solución (Modelo S1710). Deje reposar esta solución en la base por 20 min. mientras limpia todas las superficies interiores con un cepillo blando. Quite el sarro frotando la base con un trapo humedecido con vinagre blanco sin diluir. 3. Enjuague con agua tibia limpia para extraer la solución limpiadora antes de desinfectar el tanque. Para desinfectar la base y los tanques del humidificador : 1. Llene cada tanque hasta la mitad con agua y 1/2 cucharadita de blanqueador de cloro. 2. Deje que la solución trabaje por 20 minutos, sacudiendo los tanques de vez en cuando. Moje todas las superficies. 3. Vacíe cuidadosamente la base y los tanques después de 20 minutos y enjuague hasta que ya no se pueda detectar el olor a cloro. Seque con una tela limpia o con toalla de papel. 4. Coloque el filtro nuevamente en el tanque y vuelva a cargar el tanque de agua como se indica en las Instrucciones de Funcionamiento, y encienda la unidad. INSTRUCCIONES PARA GUARDAR Cuando no utilice su humidificador durante un período prolongado de tiempo : 1. Elimine los filtros. NO los deje dentro de la unidad. 2. Limpie y seque bien el humidificador según se detalla anteriormente en la sección: instrucciones de mantenimiento semanales. NO deje agua dentro de la unidad cuando guarde el humidificador. Si queda agua, la unidad podría quedar inutilizable para la próxima temporada. 3. Coloque el humidificador en su empaque original y guárdelo en un lugar fresco y seco. 4. Encargue su filtro de repuesto para el próximo año. ACCESORIOS DE REPUESTO Puede ordenar accesorios de repuesto de una de las siguientes formas : • Visite su distribuidor local • Valla a www.sunbeam.com • Llame a servicio al consumidor al 1-888-264-9669 5/9/11 3:14 PM
  • Page 1 1
  • Page 2 2

Sunbeam SCM630BC-NUM Manual de usuario

Categoría
Humidificadores
Tipo
Manual de usuario
Este manual también es adecuado para

en otros idiomas