Cooper Lighting FSL2030 Flood Series Guía de instalación

Categoría
Focos
Tipo
Guía de instalación

Este manual también es adecuado para

2
3. Connect fixture black wire to house black wire and
fixture white wire to house white wire using wire
nuts (E) provided.
4. Connect house ground wire and fixture ground wire
to the mounting bracket (B) using the green ground
screw on the mounting bracket.
5. Attach fixture (A) to the mounting bracket (B) using
(2) #8 x 1-1/4 in. screws (F) provided. Be sure no
loose wires remain sticking out from underneath
the coverplate. Insert the decorative screw cover
caps (G) into the screw holes on the coverplate for a
finished appearance (Fig. 5).
6. Apply silicone caulk around the edges of the
coverplate to provide a watertight seal from rain
and moisture.
7. Turn on power at main fuse / breaker box.
TROUBLESHOOTING
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Al utilizar el producto, siempre se deben seguir las precauciones
básicas, incluído lo siguiente:
Tenga en cuenta todas las advertencias, incluyendo las advertencias a continuación
Y aquellas incluidas en el producto.
Guarde estas instrucciones y advertencias.
Sólo para uso en exteriores.
cULus para ubicaciones mojadas.
Desensamblar la lámpara anulará la garantía.
La lámpara es percableada y ensamblado para facilitar la instalación.
Lea y siga estas instrucciones.
Riesgo de fuego/descarga eléctrica. Si no está capacitado, consulte a un electricista.
Antes de instalar o dar mantenimiento desconecte el suministro eléctrico en la caja de
fusibles o interruptores.
PRECAUCIÓN
Conecte el portalámparas a una fuente de energía de 120 Voltios, 60 Hz. Cualquier
otro tipo de conexión anula la garantía.
El portalámparas debe ser instalado por personas con experiencia en
cableado doméstico o por un electricista calificado. El sistema eléctricoy el método de
conexión eléctrica del portalámparas debe cumplir con el Código eléctrico nacional y
los códigos locales sobre edificios.
El accesorio diseñado para la pared o el montaje del alero a una caja de conexiones
solamente. Instale el accesorio en una caja de empalmes estándar embutida con
puesta a tierra apta para lugares húmedos.
No instalar por debajo de 1,5 metros (5 pies).
GUARDE ESTAS INSTRUCCIONES.
PARA OBTENER LOS MEJORES RESULTADOS
Instale el accesorio a una altura de 3 a 4,6 metros
(10 a 15 pies) por encima del suelo.
Cuando instale dos portalámparas en un único
interruptor, asegúrese de que el interruptor
esté clasificado para, por lo menos, una carga
inductiva 1 A.
MONTAJE Y CABLEADO DEL ACCESORIO
ADVERTENCIA: Riesgo de choque eléctrico.
Antes de la instalación o reparación, desconecte
la alimentación eléctrica en el fusible o interrupto
automático.
NOTA: El accesorio puede ser montado en la pared
o el alero (Fig. 1).
NOTA: La cubierta se adapta a las cajas eléctricas
empotradas (Fig. 2). La caja eléctrica debe tener
una profundidad mínima de 1-1/2 pulg. (3,81 cm)
para asegurar una instalación adecuada en
aplicaciones empotradas.
1. Alinee los agujeros en la soporte de montaje (B)
con los agujeros en su caja de conexiones. Usando
ya sea (2) tornillos N.° 6 ó (2) tornillos N.° 8 (D)
(dependiendo del tamaño de los agujeros en la
caja de conexiones), fije la soporte de montaje a la
caja de conexiones (Fig. 3).
ESPAÑOL
ADVERTENCIA
Redonda
1-1/2 pulg.
Octagonal
1-1/2 pulg.
2
3
D
B
D
Problem Cause / Solution
No power to the fixture.
Check if circuit breaker tripped.
Conrm wall switch is ON.
TURN OFF POWER BEFORE CONTINUING.
Wiring to the unit is loose.
Confirm wiring is properly secured.
Light does not
come ON.
2-YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
Cooper Lighting, LLC (“Cooper Lighting”) warrants to customers that, for a period of two years
from the date of purchase, Cooper Lighting’s products will be free from defects in materials
and workmanship. The obligation of Cooper Lighting under this warranty is expressly limited
to the provision of replacement products. This warranty is extended only to the original
purchaser of the product. A purchaser’s receipt or other proof of date of original purchase
acceptable to Cooper Lighting. This is required before warranty performance shall be rendered.
This warranty does not apply to Cooper Lighting products that have been altered or repaired
or that have been subjected to neglect, abuse, misuse or accident (including shipping damages).
This warranty does not apply to products not manufactured by Cooper Lighting which have been
supplied, installed, and/or used in conjunction with Cooper Lighting products. Damage to the
product caused by replacement bulbs or corrosion or discoloration of brass components are
not covered by this warranty.
LIMITATION OF LIABILITY:
IN NO EVENT SHALL COOPER LIGHTING BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT,
STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL
THE LIABILITY OF COOPER LIGHTING FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR
CONNECTED WITH THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE,
REPAIR OR MODIFICATION OF COOPER LIGHTING PRODUCTS, OR SUPPLY OF ANY REPLACEMENT
PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF COOPER LIGHTING PRODUCTS GIVING RISE
TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES.
To obtain warranty service, please contact Cooper Lighting, LLC, at 1-800-334-6871, press
option 2 for Customer Service, or via e-mail [email protected] and
include the following information:
• Name, address and telephone number
• Date and place of purchase
• Catalog and quantity purchase
• Detailed description of problem
All returned products must be accompanied by a Return Goods Authorization Number issued
by the Company and must be returned freight prepaid. Any product received without a Return
Goods Authorization Number from the Company will be refused.
Cooper Lighting, LLC is not responsible for merchandise damaged in transit. Repaired or
replaced products shall be subject to the terms of this warranty and are inspected when
packed. Evident or concealed damage that is made in transit should be reported at once to
the carrier making the delivery and a claim filed with them.
Reproductions of this document without prior written approval of Cooper Lighting, LLC are strictly prohibited.
For assistance, call 1-800-334-6871 or e-mail us at [email protected].
Printed in China
ARTÍCULOS NECESARIOS
(se compran por separado)
Destornillador en cruz (Phillips)
Calafateo de silicona resistente a la intemperie
F
G
A
5
F
G
1
Montaje de pared
Montaje de alero
3
2. Pase los cables del artefacto a través de la junta de
la placa de cubierta (C) (Fig. 4).
3. Conecte el alambre negro del accesorio al alambre
negro de la casa el alambre blanco del accesorio al
alambre blanco de la casa usando las tuercas para
alambre (E) suministrados.
4. Conecte el cable a tierra de la casa y el del
accesorio al soporte de montaje (AA) utilizando
el tornillo verde de puesta a tierra del soporte
de montaje.
5. Fije el accesorio al soporte de montaje utilizando
los (2) tornillos N.° 8 x 31.75 mm (1-1/4 pulg.)
provistos. Asegúrese de que no queden cables
sueltos a la vista por debajo de la placa protectora.
Introduzca las cubiertas tapatornillos decorativas
en los orificios de los tornillos de la placa protectora
para lograr el toque final de terminación (Fig. 5).
6. Aplique sellador de silicona alrededor de los bordes
de la placa de cierre y en todos los agujeros, para
formar un sello impermeable a la lluvia y humedad.
7. Active la fuente de alimentación en la caja de
fusibles/interruptor automático.
DIAGNOSTICO Y SOLUCION DE PROBLEMAS
Problem Cause / Solution
No llega electricidad al portalámparas.
Revise si el interruptor de circuito ha saltado.
Confirme que el interruptor de pared esté encendido.
DESCONECTE LA CORRIENTE ELECTRICA ANTES DE CONTINUAR.
El cableado hacia la unidad está flojo.
Confirme que el cableado esté correctamente asegurado.
La luce no
se enciende.
Para obtener el servicio de la garantía comuníquese con Cooper Lighting, LLC, al
1-800-334-6871, presione la opción 2 para el Servicio al Cliente, o por correo electrónico a
[email protected] e incluya la siguiente información:
• Nombre, dirección y número de teléfono
• Fecha y lugar de compra
• Catálogo y cantidad de la compra
• Descripción detallada del problema
Todos los productos devueltos deben estar acompañados por un Número de autorización
de productos devueltos emitido por la compañía y deben devolverse con flete prepagado.
Se rechazará todo producto recibido sin un Número de autorización de productos devueltos
desde la compañía.
Cooper Lighting, LLC no se hace responsable por la mercancía dañada durante el transporte.
Los productos reparados o reemplazados estarán sujetos a los términos de esta garantía y se
inspeccionan al ser empacados. El daño evidente y oculto que se provoque durante el
transporte se debe informar de inmediato al transportista que realiza la entrega y se debe
presentar un reclamo.
La reproducción de este documento sin la aprobación previa por escrito de Cooper Lighting, LLC está estrictamente prohibida.
Para solicitar ayuda, llame al 1-800-334-6871 o envíe un correo electrónico a [email protected].
Impreso en China
Customer First Center
1121 Highway 74 South, Peachtree City, GA 30269
www.cooperlighting.com
© 2012 Cooper Lighting, LLC
09/12
825-0785
4
Caja de
conexiónes
C
A
E
B
E
F
G
A
5
F
G
GARANTIA LIMITADA DE 2 AÑOS
LA SIGUIENTE GARANTÍA ES EXCLUSIVA Y REEMPLAZA A TODAS LAS DEMÁS GARANTÍAS, YA
SEAN IMPLÍCITAS, EXPLÍCITAS O ESTATUTARIAS, INCLUIDAS, ENTRE OTRAS, LAS GARANTÍAS
DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN PARTICULAR.
Cooper Lighting, LLC (“Cooper Lighting”) garantiza a sus clientes que los productos de Cooper
Lighting no presentarán defectos en los materiales y en la fabricación durante un período de
dos años desde la fecha de compra. La obligación de Cooper Lighting según esta garantía se
limita expresamente al suministro de los productos de reemplazo. Esta garantía se extiende
sólo para el comprador original del producto. Un recibo de compra u otra prueba de la fecha
de compra original aceptable para Cooper Lighting. Esto es necesario para la ejecución de
la garantía.
Esta garantía no se aplica a los productos de Cooper Lighting que hayan sido alterados o
reparados o que estuvieron sujetos a negligencia, abuso, mal uso o accidente (incluso los
daños durante el envío). Esta garantía no se aplica a los productos Cooper Lighting no
fabricados por Cooper Lighting que hayan sido suministrados, instalados o utilizados junto con
los productos Cooper Lighting. Los daños del producto causados por bombillas de reemplazo,
corrosión o decoloración de los componentes de latón no están cubiertos por esta garantía.
LIMITACIÓN DE RESPONSABILIDAD:
COOPER LIGHTING NO SERÁ RESPONSABLE LEGAL EN NINGÚN CASO DE DAÑOS INDIRECTOS,
ACCIDENTALES O RESULTANTES (SIN IMPORTAR LA ACCIÓN LEGAL, YA SEA POR CONTRATO,
RESPONSABILIDAD ESTRICTA O DE FORMA EXTRACONTRACTUAL INCLUYENDO LA
NEGLIGENCIA), NI POR TAMPOCO DE LA PÉRDIDA DE GANANCIAS; COOPER LIGHTING
TAMPOCO SE HACE RESPONSABLE POR DAÑOS QUE SURJAN O ESTÉN CONECTADOS CON ESTOS
RMINOS O CON LA FABRICACIÓN, VENTA, ENTREGA, USO, MANTENIMIENTO, REPARACIÓN O
MODIFICACIÓN DE LOS PRODUCTOS DE COOPER LIGHTING O DEL SUMINISTRO DE CUALQUIER
PIEZA DE REPUESTO QUE EXCEDA EL PRECIO DE COMPRA DE LOS PRODUCTOS DE COOPER
LIGHTING QUE ORIGINAN UN RECLAMO. NO SE ACEPTARÁN CARGOS POR MANO DE OBRA
PARA QUITAR O INSTALAR LOS ACCESORIOS.

Transcripción de documentos

3. Connect fixture black wire to house black wire and fixture white wire to house white wire using wire nuts (E) provided. 4. Connect house ground wire and fixture ground wire to the mounting bracket (B) using the green ground screw on the mounting bracket. 5. Attach fixture (A) to the mounting bracket (B) using (2) #8 x 1-1/4 in. screws (F) provided. Be sure no loose wires remain sticking out from underneath the coverplate. Insert the decorative screw cover caps (G) into the screw holes on the coverplate for a finished appearance (Fig. 5). 6. Apply silicone caulk around the edges of the coverplate to provide a watertight seal from rain and moisture. 7. Turn on power at main fuse/breaker box. INSTRUCCIONES IMPORTANTES DE SEGURIDAD Al utilizar el producto, siempre se deben seguir las precauciones básicas, incluído lo siguiente: • Tenga en cuenta todas las advertencias, incluyendo las advertencias a continuación Y aquellas incluidas en el producto. • Guarde estas instrucciones y advertencias. • Sólo para uso en exteriores. • cULus para ubicaciones mojadas. • Desensamblar la lámpara anulará la garantía. • La lámpara es percableada y ensamblado para facilitar la instalación. 5 A F G ADVERTENCIA F G • Lea y siga estas instrucciones. • Riesgo de fuego/descarga eléctrica. Si no está capacitado, consulte a un electricista. • Antes de instalar o dar mantenimiento desconecte el suministro eléctrico en la caja de fusibles o interruptores. TROUBLESHOOTING Problem Cause / Solution Light does not come ON. No power to the fixture. • Check if circuit breaker tripped. • Confirm wall switch is ON. TURN OFF POWER BEFORE CONTINUING. Wiring to the unit is loose. • Confirm wiring is properly secured. PRECAUCIÓN • Conecte el portalámparas a una fuente de energía de 120 Voltios, 60 Hz. Cualquier otro tipo de conexión anula la garantía. • El portalámparas debe ser instalado por personas con experiencia en cableado doméstico o por un electricista calificado. El sistema eléctricoy el método de conexión eléctrica del portalámparas debe cumplir con el Código eléctrico nacional y los códigos locales sobre edificios. • El accesorio diseñado para la pared o el montaje del alero a una caja de conexiones solamente. Instale el accesorio en una caja de empalmes estándar embutida con puesta a tierra apta para lugares húmedos. • No instalar por debajo de 1,5 metros (5 pies). GUARDE ESTAS INSTRUCCIONES. 2-YEAR LIMITED WARRANTY THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Cooper Lighting, LLC (“Cooper Lighting”) warrants to customers that, for a period of two years from the date of purchase, Cooper Lighting’s products will be free from defects in materials and workmanship. The obligation of Cooper Lighting under this warranty is expressly limited to the provision of replacement products. This warranty is extended only to the original purchaser of the product. A purchaser’s receipt or other proof of date of original purchase acceptable to Cooper Lighting. This is required before warranty performance shall be rendered. This warranty does not apply to Cooper Lighting products that have been altered or repaired or that have been subjected to neglect, abuse, misuse or accident (including shipping damages). This warranty does not apply to products not manufactured by Cooper Lighting which have been supplied, installed, and/or used in conjunction with Cooper Lighting products. Damage to the product caused by replacement bulbs or corrosion or discoloration of brass components are not covered by this warranty. LIMITATION OF LIABILITY: IN NO EVENT SHALL COOPER LIGHTING BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL THE LIABILITY OF COOPER LIGHTING FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR MODIFICATION OF COOPER LIGHTING PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF COOPER LIGHTING PRODUCTS GIVING RISE TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES. To obtain warranty service, please contact Cooper Lighting, LLC, at 1-800-334-6871, press option 2 for Customer Service, or via e-mail [email protected] and include the following information: • Name, address and telephone number • Date and place of purchase • Catalog and quantity purchase • Detailed description of problem All returned products must be accompanied by a Return Goods Authorization Number issued by the Company and must be returned freight prepaid. Any product received without a Return Goods Authorization Number from the Company will be refused. Cooper Lighting, LLC is not responsible for merchandise damaged in transit. Repaired or replaced products shall be subject to the terms of this warranty and are inspected when packed. Evident or concealed damage that is made in transit should be reported at once to the carrier making the delivery and a claim filed with them.­­ PARA OBTENER LOS MEJORES RESULTADOS • Instale el accesorio a una altura de 3 a 4,6 metros (10 a 15 pies) por encima del suelo. • Cuando instale dos portalámparas en un único interruptor, asegúrese de que el interruptor esté clasificado para, por lo menos, una carga inductiva 1 A. MONTAJE Y CABLEADO DEL ACCESORIO ADVERTENCIA: Riesgo de choque eléctrico. Antes de la instalación o reparación, desconecte la alimentación eléctrica en el fusible o interrupto automático. NOTA: El accesorio puede ser montado en la pared o el alero (Fig. 1). 1 Montaje de pared Montaje de alero NOTA: La cubierta se adapta a las cajas eléctricas empotradas (Fig. 2). La caja eléctrica debe tener una profundidad mínima de 1-1/2 pulg. (3,81 cm) para asegurar una instalación adecuada en aplicaciones empotradas. 2 1-1/2 pulg. Redonda Reproductions of this document without prior written approval of Cooper Lighting, LLC are strictly prohibited. For assistance, call 1-800-334-6871 or e-mail us at [email protected]. Printed in China 1. Alinee los agujeros en la soporte de montaje (B) con los agujeros en su caja de conexiones. Usando ya sea (2) tornillos N.° 6 ó (2) tornillos N.° 8 (D) (dependiendo del tamaño de los agujeros en la caja de conexiones), fije la soporte de montaje a la caja de conexiones (Fig. 3). ESPAÑOL ARTÍCULOS NECESARIOS (se compran por separado) • Destornillador en cruz (Phillips) • Calafateo de silicona resistente a la intemperie 3 B D D 2 1-1/2 pulg. Octagonal Para obtener el servicio de la garantía comuníquese con Cooper Lighting, LLC, al 1-800-334-6871, presione la opción 2 para el Servicio al Cliente, o por correo electrónico a [email protected] e incluya la siguiente información: • Nombre, dirección y número de teléfono • Fecha y lugar de compra • Catálogo y cantidad de la compra • Descripción detallada del problema Todos los productos devueltos deben estar acompañados por un Número de autorización de productos devueltos emitido por la compañía y deben devolverse con flete prepagado. Se rechazará todo producto recibido sin un Número de autorización de productos devueltos desde la compañía. Cooper Lighting, LLC no se hace responsable por la mercancía dañada durante el transporte. Los productos reparados o reemplazados estarán sujetos a los términos de esta garantía y se inspeccionan al ser empacados. El daño evidente y oculto que se provoque durante el transporte se debe informar de inmediato al transportista que realiza la entrega y se debe presentar un reclamo. 2. Pase los cables del artefacto a través de la junta de la placa de cubierta (C) (Fig. 4). 4 C B E Caja de conexiónes A E 3. Conecte el alambre negro del accesorio al alambre negro de la casa el alambre blanco del accesorio al alambre blanco de la casa usando las tuercas para alambre (E) suministrados. 4. Conecte el cable a tierra de la casa y el del accesorio al soporte de montaje (AA) utilizando el tornillo verde de puesta a tierra del soporte de montaje. 5. Fije el accesorio al soporte de montaje utilizando los (2) tornillos N.° 8 x 31.75 mm (1-1/4 pulg.) provistos. Asegúrese de que no queden cables sueltos a la vista por debajo de la placa protectora. Introduzca las cubiertas tapatornillos decorativas en los orificios de los tornillos de la placa protectora para lograr el toque final de terminación (Fig. 5). 6. Aplique sellador de silicona alrededor de los bordes de la placa de cierre y en todos los agujeros, para formar un sello impermeable a la lluvia y humedad. 7. Active la fuente de alimentación en la caja de fusibles/interruptor automático. La reproducción de este documento sin la aprobación previa por escrito de Cooper Lighting, LLC está estrictamente prohibida. Para solicitar ayuda, llame al 1-800-334-6871 o envíe un correo electrónico a [email protected]. Impreso en China Customer First Center 1121 Highway 74 South, Peachtree City, GA 30269 www.cooperlighting.com © 2012 Cooper Lighting, LLC 5 A F G F G DIAGNOSTICO Y SOLUCION DE PROBLEMAS Problem Cause / Solution La luce no se enciende. No llega electricidad al portalámparas. • Revise si el interruptor de circuito ha saltado. • Confirme que el interruptor de pared esté encendido. DESCONECTE LA CORRIENTE ELECTRICA ANTES DE CONTINUAR. El cableado hacia la unidad está flojo. • Confirme que el cableado esté correctamente asegurado. GARANTIA LIMITADA DE 2 AÑOS LA SIGUIENTE GARANTÍA ES EXCLUSIVA Y REEMPLAZA A TODAS LAS DEMÁS GARANTÍAS, YA SEAN IMPLÍCITAS, EXPLÍCITAS O ESTATUTARIAS, INCLUIDAS, ENTRE OTRAS, LAS GARANTÍAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN PARTICULAR. Cooper Lighting, LLC (“Cooper Lighting”) garantiza a sus clientes que los productos de Cooper Lighting no presentarán defectos en los materiales y en la fabricación durante un período de dos años desde la fecha de compra. La obligación de Cooper Lighting según esta garantía se limita expresamente al suministro de los productos de reemplazo. Esta garantía se extiende sólo para el comprador original del producto. Un recibo de compra u otra prueba de la fecha de compra original aceptable para Cooper Lighting. Esto es necesario para la ejecución de la garantía. Esta garantía no se aplica a los productos de Cooper Lighting que hayan sido alterados o reparados o que estuvieron sujetos a negligencia, abuso, mal uso o accidente (incluso los daños durante el envío). Esta garantía no se aplica a los productos Cooper Lighting no fabricados por Cooper Lighting que hayan sido suministrados, instalados o utilizados junto con los productos Cooper Lighting. Los daños del producto causados por bombillas de reemplazo, corrosión o decoloración de los componentes de latón no están cubiertos por esta garantía. LIMITACIÓN DE RESPONSABILIDAD: COOPER LIGHTING NO SERÁ RESPONSABLE LEGAL EN NINGÚN CASO DE DAÑOS INDIRECTOS, ACCIDENTALES O RESULTANTES (SIN IMPORTAR LA ACCIÓN LEGAL, YA SEA POR CONTRATO, RESPONSABILIDAD ESTRICTA O DE FORMA EXTRACONTRACTUAL INCLUYENDO LA NEGLIGENCIA), NI POR TAMPOCO DE LA PÉRDIDA DE GANANCIAS; COOPER LIGHTING TAMPOCO SE HACE RESPONSABLE POR DAÑOS QUE SURJAN O ESTÉN CONECTADOS CON ESTOS TÉRMINOS O CON LA FABRICACIÓN, VENTA, ENTREGA, USO, MANTENIMIENTO, REPARACIÓN O MODIFICACIÓN DE LOS PRODUCTOS DE COOPER LIGHTING O DEL SUMINISTRO DE CUALQUIER PIEZA DE REPUESTO QUE EXCEDA EL PRECIO DE COMPRA DE LOS PRODUCTOS DE COOPER LIGHTING QUE ORIGINAN UN RECLAMO. NO SE ACEPTARÁN CARGOS POR MANO DE OBRA PARA QUITAR O INSTALAR LOS ACCESORIOS. 3 09/12 825-0785
  • Page 1 1
  • Page 2 2
  • Page 3 3

Cooper Lighting FSL2030 Flood Series Guía de instalación

Categoría
Focos
Tipo
Guía de instalación
Este manual también es adecuado para