NuTone 644201 Installation Instructions Manual

Categoría
Campanas de cocina
Tipo
Installation Instructions Manual

Este manual también es adecuado para

64000 SERIES
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 11 TO 13
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)
REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register
V03515 rev. J
HB0056
INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
!
!
WARNING WARNING
- 2 -
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power
off at service panel and lock service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by qualified personnel in accordance with all
applicable codes and standards, including fire-rated
construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer’s guidelines and
safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state
speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that
may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not
be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie
sheet or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. IF THE FLAMES
DO NOT GO OUT IMMEDIATELY, EVACUATE AND
CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be
burned.
3. DO NOT USE WATER, including wet dishcloths or
towels – This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area where
it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
3. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated.
The motor will restart when it will be cooled down. If
the motor continues to shut off and restart, have the
hood serviced.
4. For best capture of cooking impurities, the bottom of the
hood should be at a minimum of 20’ (24” over a gas range)
and at a maximum of 30” above the cooking surface.
5. Two installers are recommended because of the large
size and weight of this hood.
6. To reduce the risk of fire and to properly exhaust air,
be sure to duct air outside – Do not exhaust air into
spaces within walls or ceiling or into attics, crawl
space or garage.
7. This product is equipped with a thermostat which may
start blower automatically. To reduce the risk of injury
and to prevent power from being switched on
accidentally, switch power off at service panel and
lock or tag service panel.
8. Because of the high exhausting capacity of this hood,
you should make sure enough air is entering the
house to replace exhausted air by opening a window
close to or in the kitchen.
9. To reduce the risk of fire and electric shock, the
Broan Elite 64000 Series hood must be installed with
Broan interior blower models P5 or P8; Broan exterior
blower models 331H, 332H, 335 or 336; Broan
in-line blowers models HLB3, HLB6, HLB9,
HLB11.
Other blowers cannot be substituted.
(Blowers sold separately.)
10. Use with approved cord-connection kit only.
11. Please read specification label on product for
further information and requirements.
!
!
HL0070
- 3 -
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
Model 418
10” round
adjustable elbow
(optional)
Model 412
transition
(3
1
/4” x 10” to 7”)
Adapter and damper 3
1
/4” x 10”
(supplied with P5 and P8 blowers)
Adapter and damper 3
1
/4 x 14’
(supplied with P8 blower)
Standard duct
(3
1
/4” x 10”)
Duct
(3
1
/4” x 14”)
Model P5
single-blower
(500 cfm)
64000 SERIES HOOD
- 64000 SERIES RANGE HOOD SYSTEM -
INTERIOR BLOWERS
Flow deviator
(vertical exhaust only)
(supplied with
P5 and P8 blowers)
Model 647
(7” Rd wall cap)
Model 634 or 644
(roof cap)
Model 643
(8” Rd wall cap)
8” round
standard
duct
Model 407
(7” round -
2 ft. sections)
Model 413
transition
(3
1
/4” x 10” to 8”)
Model 459 transition
(3
1
/4” x 14” to 8”)
Model P8 dual-blower (900 cfm)
for use with 36’ hoods or wider
NOTE: The dual blower P8 can be
installed either with 3
1
/4 x 14’’ or
3
1
/4’’ x 10’ ducts. For optimal air
and quiet sound performance,
use 3
1
/4’’ x 14’ ducts.
Rough-in kit
(supplied with P5 and P8 blowers)
Model 415
7” round adjustable
elbow (optional)
- 4 -
HL0071
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
64000 SERIES HOOD
- 64000 SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
332KR in-line and exterior blower
rough-in kit - Purchase separately.
Model 418
10” Rd
adjustable elbow
(optional)
Model HLB3 (280 cfm)
in-line blower
(includes one 8” to 10”
round transition)
Model 331H (600 cfm)
or 332H (900 cfm)
exterior blower
Model 335 (1200 cfm)
or 336 (1500 cfm)
exterior blower
Model 441
(10” Rd wall cap)
Model 437
(High capacity roof cap)
Model 441
(10” Rd wall cap)
Model 421
(10” Rd. vert.
in-line damper)
Recommended
for use with
exterior blowers
Model 410
(10” Rd duct -
2ft. sections)
Model HLB6 (600 cfm)
in-line blower
(includes two 4½” x 18½”
to 10’ round transitions)
Model HLB9 (800 cfm)
or HLB11 (1100 cfm)
in-line blower
(includes two 8” x 12” to
10’ round transitions)
- 5 -
1. SELECT BLOWER OPTION AND INSTALL DUCTWORK
Either an interior or exterior blower or in-line blower may be used with this hood. The Broan Elite 64000 Series must be
installed with blower models P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers
cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 3, 6, 9, 10,
12 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7” or 8” round
ducts, or 3
1
/4 x 14’ duct, use a transition. Use 2” duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 20’ for an electric range and 24’ for a gas
range. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion.
Hood with
interior blower
3¼ x 10 or
3¼ x 14 duct
Roof cap
Wall
cap
HH0029A
3¼ x 14 to 8
transition if
3¼ x 14 duct
20 minimum above
cooking surface
(24 for gas)
MODEL P5 (SINGLE) OR
P8 (DOUBLE) INTERIOR BLOWER
TYPICAL RECTANGULAR DUCTWORK
Hood
7 or 8”
round duct
Roof cap
Wall
cap
3¼ x 10 to 7
or 8” transition
HH0015A
20 minimum above
cooking surface
(24 for gas)
MODEL P5 (SINGLE) OR
P8 (DOUBLE) INTERIOR BLOWER
7’ OR 8’ ROUND DUCTWORK
Hood
10 round duct
Exterior blower
HH0016A
Exterior
blower
20 minimum above
cooking surface
(24 for gas)
MODEL 331H, 332H, 335 OR 336
EXTERIOR BLOWER TYPICAL DUCTWORK
MODEL HLB3, HLB6, HLB9 OR HLB11
IN-LINE BLOWER TYPICAL DUCTWORK
- 6 -
2. PREPARE THE INSTALLATION
Make sure that the following items are included:
- Range hood
- Accessories:
• Filters
• Bag of parts including:
(4) lock nuts, (1) wire clamp, (8) 1/2” double thread screws, (2) wire connectors,
(2) 1/2” standard screws, (6) 3/8” screws.
Parts sold separately:
- Interior blower Model P5 includes blower, rough-in kit, flow deviator and 3
1
/4” x 10” adapter
- Interior blower Model P8 includes blower, rough-in kit, flow deviator and 3
1
/4” x 10” adapter and 3
1
/4” x 14” adapter
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)
- In-line and exterior blower rough-in plate model 332KR, required for all In-line or Exterior Blowers
- Exterior blower assembly 331H, 332H, 335 or 336
- Halogen lights (120V, 50W, PAR 20)
- Heat lamps (120V, IR 175W, PAR 38)
- RMP Series Backsplash (optional)
- Baffle filters (optional)
- Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options
and model numbers.
NOTE: For cabinets with recessed bottom, attach wood filler strips (not included) on each sides, as shown below.
Use two (2) 2-inch wide strips for 30’ wide hoods, and four (4) 2-inch wide strips for wider hoods, cut to length.
See below for wood filler strip locations.
HD0079
A
A
B C
3. INSTALL BACKSPLASH (OPTIONAL)
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting
screws. In order to be able to install the backsplash, make sure you have at least 18’ clearance between bottom of
hood and range control panel or cooktop. (See instructions packed with backsplash.)
HOOD LOCATIONS
WIDTHS AB C
30’ 2’ N/AN/A
36’ 2’ 4
1
/2’’ 4
1
/2’’
42’ 2’ 7
1
/4’’ 8
1
/4’’
48’ 4’ 10
1
/4’’ 11
1
/4’’
4. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR)
INTERIOR BLOWER: Follow all subsequent steps of this manual.
EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 6, 10, 12 and up of
the present manual.
- 7 -
Removing horizontal knockout opening on back of hood
HD0076
5. CHOOSE THE OPENING (INTERIOR BLOWER)
Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate).
See pictures below.
CAUTION
When using P5 blower, remove the 10’ wide knockout (smaller part). If using P8 blower, remove
the knockout corresponding to the ducting installed (10’ or 14’’).
Removing vertical knockout opening on rough-in plate
HD0077
10’ KNOCKOUT
14’ KNOCKOUT
14’
KNOCKOUT
10’
KNOCKOUT
6. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)
INTERIOR BLOWER: Secure the rough-in plate (provided with the P5 and P8 blower) inside the hood with four (4)
lock nuts. See picture below.
EXTERIOR OR IN-LINE BLOWER: Purchase Model 332KR separately. Refer to instructions included with the rough-in
kit. Secure the rough-in plate inside the hood with (4) lock nuts.
HD0042
Inserting deviator into hood vertical opening
7. INSTALL THE DEVIATOR (INTERIOR BLOWER)
YOU MUST install the deviator if you choose to vent the hood vertically.
Install the deviator as shown.
NOTE: If installed correctly, the deviator will protrude about 1/8” above the
rough-in plate.
HD0003
- 8 -
8. INSTALL THE ADAPTER (INTERIOR BLOWER)
Using two (2) standard 1/2’ screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood
using duct tape.
HD0005
HD0006
9. INSTALL THE HOOD (ALL BLOWERS)
HD0043
INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the
screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws
leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover, place the wire clamp, insert the cable in the hood and
tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the
adapter/damper assembly enters the ducting. Secure the hood by tightening the screws completely.
EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood to its location. Mark the
position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread
screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover on top of the hood and connect wiring (see
instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure
the hood by tightening the screws completely.
- 9 -
10. CONNECT WIRING (ALL BLOWERS)
INTERIOR BLOWER: Connect cable into wiring box using wire
connectors.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and
GREEN or BARE wire under ground screw. Reinstall wiring cover. DO
NOT FORGET TO CONNECT THE GROUND.
IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included
witn in-line or exterior blower).
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel
and lock service disconnecting means to prevent power to be switched on accidentally.
!
1
HD0007
1) Ground screw
11. INSTALL THE BLOWER (INTERIOR BLOWER)
The blower must be installed to the rough-in plate using (4) 3/8” screws for the single blower unit and (6) 3/8” screws
for the dual blower unit. Remove the cover from the blower assembly. Remove the impeller(s) by pulling them out gen-
tly (see pictures below).
HD0021
HD0022
- 10 -
11. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D)
Secure the blower by installing 2 more screws into the locations shown in the pictures below (single blower or dual
blower). Reinstall impeller(s) and cover.
Plug the power supply to the 3-prong male connector (A) and
the blower unit into the 2-prong female receptacle (B) inside the
hood.
HE0003
WARNING
Never plug the 2-prong blower cord to the 3-prong power supply cord.
!
FOR DUAL BLOWER UNIT, MAKE
SURE THE IMPELLERS ARE
CORRECTLY INSTALLED, THE HOOD
WILL NOT WORK PROPERLY IF
REVERSED. Both impellers are different
in the dual blower, one rotates clockwise
and the other counterclockwise. Each
wheel and motor have an arrow and a
number on them, you have to match
them correctly (see drawing beside).
Install screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten screws down
fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower
to its position (screws in the small part of the keyhole). Tighten the screws.
HD0044
HD0044
Single blower (P5)
Dual blower (P8)
HD0080
HD0081
Single blower (P5)
21
HD0023
FRONT
A
B
Dual blower (P8)
HD0023
1
2
- 11 -
12. LIGHT BULBS
This range hood uses 50W halogen lamps. (120V, 50W, PAR 20)
Install the lamps by rotating them clockwise into their socket holder.
13. HEAT LAMPS
The heat lamps required are 120V, 175W max, infrared bulbs. (120V, IR 175W, PAR 38)
White halogen lights can be used if warming shelves are not used. (120V, 90W, PAR 38)
Install the lamps by rotating them clockwise into their socket holder.
14. INSTALL FILTERS
It is recommended to install side filters first and finish with center one(s).
1. Insert upper end of filter into the hood (tab end).
2. Raise lower end toward the inside of hood.
3. Position lower end of filter into channel and pull on filter tab.
4. While pulling the filter tab, slide the filter top under the inner retaining piece.
Baffle filters are available as an option (see instruction sheet included with baffle filters).
HD0009
HD0010
15. USE AND CARE
Grease filters and impeller(s).
The grease filters, impeller(s) and grease rail should be cleaned frequently. Use a warm detergent solution.
Grease filters and impeller are dishwasher safe.
Remove filters by pushing filters towards the back of hood and rotating filters downward.
1
1) Tabs
- 12 -
15. USE AND CARE (CONT’D)
Hood cleaning
Stainless steel cleaning: How to maintain its « BRIGHT LOOK »
Do:
- Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
- Always clean in the direction of original polish lines.
- Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
- You may also use a specialized household stainless steel cleaner.
Don’t:
- Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
- Do not use any harsh or abrasive cleansers.
- Do not allow dirt to accumulate.
- Do not let plaster dust or any other construction residues reach the hood. During construction or renovation, cover
the hood to make sure no dust sticks to stainless steel surface.
Avoid: when choosing a detergent
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive
and should never be used close to a range.
Enamel finish:
Clean with warm water and mild detergent only. When discoloration occurs, use a good enamel polish such as auto-
motive polish. (DO NOT use rough abrasive cleaner or porcelain cleaner.)
16. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few
minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
1
1
2
3
4
1) Warming lamp switches
2) Halogen light switches
3) ON/OFF blower switch
4) Blower speed control
HC0028
BLOWER
The blower is operated using two (2) controls.
Use the red, lighted on/off switch to start and stop the blower. When turned on, the blower will operate at the previous
setting of the speed control.
Turn the speed control knob clockwise to decrease blower speed – counterclockwise to increase speed.
COOKTOP LIGHTING (HALOGEN)
A double set of ON/OFF switches controls the halogen lights.
The front rocker controls the center light (for 42” and 48” hoods). The rear rocker controls both side lights (each switch
controls one light for 30” and 36” hood). Select one, two or three lights for best cooking lighting.
Use PAR 20, 50W halogen bulbs.
- 13 -
WARMING LAMPS (INFRARED)
Each warming lamp is controlled with its own ON/OFF switch.
Use infrared light bulbs (120V, IR175W, PAR38) or white halogen bulbs (120V, 90W, PAR38) if food warming shelves are
not used.
HEAT SENTRY
This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower
if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original setting.
WARNING
Never place highly flammable material under warming lamps.
WARNING
The HEAT SENTRY can start the blower even if the hood is turned OFF. In this case, it is impossible
to turn the blower OFF with blower switch. If you must stop the blower, do it from the main
electrical panel.
!
!
16. OPERATION (CONT’D)
WARRANTY
BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY
Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free
from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product
or part which is found to be defective under normal use and service.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been
subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone LLC),
faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some
states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not
apply to you.
BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION,
SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY.
BROAN-NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state
or province to another. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone LLC at one of the addresses or telephone
number stated below, (b) give the model number and part identification and (c) describe the nature of any defect
in the product or part. At the time of requesting warranty service, you must present evidence of the original
purchase date.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)
KEY QTY (hood width)
NO.
PART NUMBER DESCRIPTION
30 36 42” 48
- 14 -
28 910112
8
17
17
17
5
6
14
12
13
7
15
16
4
3
20
19
17
2
2
17
18
1
HL0002
SERVICE PARTS
64000 Series
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
V06750
V02264
V02773
V02772
V03435
V03436
V03501
V03507
V03502
V03503
V03504
V03505
V03517
V03518
V03519
V03520
V00673
V02512
V01869
V01582
V00606
V03509
V03510
V13216
V13217
V13218
V13219
V03686
V02544
V03598
V03515
V13278
BROAN ELITE LOGO
SOCKET LAMP
MALE CONNECTOR
FEMALE CONNECTOR
THERMOSTAT
THERMOSTAT BRACKET
SPEED CONTROLLER
SPST SINGLE SWITCH FOR WARMING LAMP
SPST DOUBLE SWITCH FOR HALOGEN LIGHT
SPST LIGHTED SINGLE SWITCH FOR BLOWER
SPEED CONTROL BUTTON
TERMINAL STRIP
10" POWER CORDS
10" CORDS FOR HEAT LAMP
10" CONTROL WIRE
10" LIGHTED SWITCH WIRE
LOCK NUT NO. 8-32
SCREW NO. 8-32 x 1/2" QUADREX
MACHINE SCREW NO. 6-32 x 1/4"
LOCK NUT NO. 6-32
SCREW NO. 8-3/8"T/B NO. 8 HEAD
RANGEMASTER FILTER 8.930
x 9.800
RANGEMASTER FILTER 11.930
x 9.800
GREASE RAIL 30"
GREASE RAIL 36"
GREASE RAIL 42"
GREASE RAIL 48"
FILTER CLIP
HALOGEN LAMP PAR 20 50 W
HEAT LAMP
INSTALLATION GUIDE
PARTS BAG ((4) lock nut no.10-32, (1) wire clamp LP16-AP, (2) wire connectors no.74B,
(8) double thread screw 6-12 x 0.5, (6) no. 8 x 3/8” screws, (2) no. 6 x 1/2" screws)
1
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
2
1
1
-
-
-
3
2
2
1
1
1
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
-
3
-
1
-
-
3
2
2
1
1
1
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
2
2
-
-
1
-
4
3
2
1
1
1
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
-
4
-
-
-
1
4
3
2
1
1
KEY
NO.
PART NUMBER DESCRIPTION QTY
- 15 -
SERVICE PARTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
V13296
V03500
V12997
V03577
V02160
V01869
V01857
V01582
V14973
V01810
V03400
V01766
V00871
V02001
V01831
V11705
V11614
V01927
V03495
V03494
V13230
V03496
V00660
V05520
V00613
1
1
1
1
1
4
1
1
1
1
1
1
3
3
2
1
1
4
1
1
1
1
1
2
2
ADAPTER AND DAMPER 3
1
/4 x 10’
AIR DEFLECTOR
SINGLE BLOWER ROUGH-IN PLATE ASSEMBLY
FOAM 1/2” x 1/2” x 12”
CAPACITOR 15MFD
MACHINE SCREW NO. 6-32 x 1/4”
WIRE COVER
LOCK NUT NO. 6-32
SINGLE BLOWER ASSEMBLY
IMPELLER RING
BLOWER IMPELLER 7.094” x 3.375” CW
MOTOR 165W CW
WASHER 3/16” ID x 3/4’ OD
MOTOR GROMMET G-431-1
8” TIE WRAP
MOTOR MOUNT
WIRE NO. 18 TEW BROWN x 10”
METRIC SCREW M4 x 6MM PAN QDRX
STRAIN RELIEF FOR BLOWER POWER CORD
36” BLOWER POWER CORD
OUTLET BOX COVER
POWER CORD, 120 VOLTS
STRAIN RELIEF FOR POWER CORD
SCREW NO. 8 x 3/8”, T/B, NO. 8 HEAD
SCREW NO. 10-32 x 3/8, TF, GREEN
SINGLE BLOWER/ROUGH-IN
(Model P5)
HL0021
19
21
18
17
20
22
2
3
23
4
1
9
6
8
5
15
14
13
6
16
12
7
11
10
21
22
23
2
3
20
24
25
1
19
18
17
16
15
13
6
9
10
11
12
14
4
5
KEY
NO.
PART NUMBER DESCRIPTION QTY
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
V14971
V13296
V03500
V14975
V03577
V01582
V02160
V01857
V01766
V03400
V14974
V01810
V03399
V03457
V00871
V01831
V11705
V11614
V02001
V01927
V03495
V03494
V14960
V00660
V03496
V05520
V00613
1
1
1
1
1
1
2
2
1
1
1
2
1
1
6
4
2
2
6
8
1
1
1
1
1
4
2
ADAPTER AND DAMPER 3
1
/4” x 14’
ADAPTER AND DAMPER 3
1
/4” x 10’
AIR DEFLECTOR
DUAL BLOWER ROUGH-IN PLATE ASSEMBLY
FOAM 1/2” x 1/2” x 12”
LOCK NUT NO. 6-32
CAPACITOR 15MFD
WIRE COVER
MOTOR 165W CW
BLOWER IMPELLER, HOOD 7.094” x 3.375” CW
DUAL BLOWER ASSEMBLY
IMPELLER RING
BLOWER IMPELLER, HOOD 7.094” x 3.375” CCW
MOTOR 165W CCW
WASHER 3/16” ID x 3/4 OD
8” TIE WRAP
MOTOR MOUNT
WIRE NO.18 TEW BROWN x 10”
MOTOR GROMMET G-431-1
METRIC SCREW M4 x 6MM PAN QDRX
STRAIN RELIEF FOR BLOWER POWER CORD
36” BLOWER POWER CORD
OUTLET BOX COVER
STRAIN RELIEF FOR POWER CORD
POWER CORD, 120 VOLTS
SCREW NO. 8 x 3/8”, T/B, NO. 8 HEAD
SCREW NO. 10-32 x 3/8”, TF, GREEN
- 16 -
SERVICE PARTS
DUAL BLOWER/ROUGH-IN
(Model P8)
7
8
GUIDE D’INSTALLATION
SÉRIE 64000
CONÇUE UNIQUEMENT POUR LA CUISSON DOMESTIQUE
INSTALLATEUR : LAISSER CE MANUEL AU PROPRIÉTAIRE
PROPRIÉTAIRE : INSTRUCTIONS D’UTILISATION ET D’ENTRETIEN EN PAGES 27 À 29
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)
ENREGISTREZ VOTRE PRODUIT EN LIGNE À : www.broan.com/register
V03515 rév.J
HB0056
LIRE ET CONSERVER CES INSTRUCTIONS
!
!
- 18 -
AVERTISSEMENT AVERTISSEMENT
AFIN DE RÉDUIRE LES RISQUES D’INCENDIE,
D’ÉLECTROCUTION OU DE BLESSURES CORPORELLES,
SUIVEZ LES INSTRUCTIONS SUIVANTES :
1. N’utilisez cet appareil que de la façon prévue par
le manufacturier. Si vous avez des questions,
contactez le manufacturier à l’adresse et au
numéro de téléphone indiqués sur la garantie.
2. Avant de réparer ou de nettoyer l’appareil, coupez
l’alimentation électrique en verrouillant le panneau de
service afin d’éviter sa remise en marche accidentelle.
Si le panneau de service ne peut être verrouillé, y
fixer un avertissement en évidence.
3. Les travaux d’installation et de raccordement
électrique doivent être effectués par une personne
qualifiée, conformément aux codes et standards
de construction, incluant ceux concernant le feu.
4. Une quantité d’air adéquate est requise afin d’assurer
une bonne combustion et l’évacuation des gaz par
la cheminée dans le cas des équipements alimentés
au gaz, afin de prévenir les retours de cheminée.
Conformez-vous aux instructions et aux standards
de sécurité des manufacturiers d’équipement de
chauffage, tel que publiés par la
National Fire
Protection Association
(NFPA), et l’
American
Society for Heating, Refrigeration and Air
Conditioning Engineers
(ASHRAE), ainsi que les
responsables des codes locaux.
5. Lorsque vous coupez ou perforez un mur ou un
plafond, prenez garde de ne pas endommager
les fils électriques ou tout appareil cachés.
6. Les ventilateurs avec conduits doivent toujours
évacuer l’air à l’extérieur.
7. Ne pas utiliser cet appareil avec une commande
de vitesse à semiconducteur additionnelle.
8. Afin de réduire les risques d’incendie, n’utilisez
que des conduits de métal.
9. Cet appareil doit être mis à la terre.
AFIN DE RÉDUIRE LES RISQUES DE FEU
DE CUISINIÈRE :
a) Ne jamais laisser les appareils de cuisson sans
surveillance lorsqu’ils sont réglés à feu vif. Les
débordements engendrent de la fumée et des
déversements graisseux pouvant s’enflammer.
Chauffez l’huile lentement, à feu doux ou moyen.
b) Toujours mettre la hotte en marche lorsque vous
cuisinez à feu vif ou que vous cuisinez des
mets flambés.
c) Nettoyez régulièrement la (les) roue(s) du ventilateur.
Ne laissez pas la graisse s’accumuler sur le
ventilateur ou les filtres.
d) Utilisez le bon format de casserole. Servez-vous
toujours de casseroles et d’ustensiles appropriés à
la dimension de la surface chauffante.
AFIN D’ÉVITER TOUT RISQUE DE BLESSURES
DANS LE CAS D’UN FEU DE CUISINIÈRE, SUIVEZ
CES DIRECTIVES* :
1. Étouffez les flammes avec un couvercle hermétique,
une tôle à biscuits ou un plateau métallique et
ensuite, éteindre le brûleur. PRENEZ SOIN
D’ÉVITER LES BRÛLURES. SI LES FLAMMES
NE S’ÉTEIGNENT PAS IMMÉDIATEMENT,
ÉVACUEZ LES LIEUX ET APPELEZ LES POMPIERS.
2. NE PRENEZ JAMAIS UNE CASSEROLE EN
FLAMMES DANS VOS MAINS – Vous pourriez
subir des brûlures.
3. N’UTILISEZ PAS D’EAU, incluant linge à vaisselle
ou serviette mouillés – ceci pourrait occasionner
une violente explosion.
4. N’utilisez un extincteur QUE DANS LE CAS OÙ:
A. Vous savez qu’il s’agit d’un extincteur de classe ABC
et que vous en connaissez le fonctionnement.
B. L’incendie est petit et limité à l’endroit où il a débuté.
C. Les pompiers ont été avisés.
D. Vous pouvez combattre l’incendie en ayant
accès à une sortie de secours.
*Tirées du
Kitchen Fire Safety Tips
publié par la NFPA.
ATTENTION
1. Pour usage domestique seulement. Ne pas utiliser pour
évacuer des vapeurs ou des produits dangereux
ou explosifs.
2. Afin d’éviter tout dommage au moteur et de débalancer
ou de rendre bruyante la roue du moteur, garder
votre appareil à l’abri des poussières de placoplâtre
et de construction/rénovation, etc.
3. Le moteur de votre hotte possède une protection
thermique qui éteindra automatiquement le moteur s’il
devient surchauffé. Le moteur repartira automatiquement
une fois refroidi. Si le moteur continue à arrêter et
à repartir, faites-le vérifier.
4. Pour une meilleure évacuation des odeurs de cuisine,le
bas de votre hotte devrait être situé à un minimum
de 20 po (24 po d’une cuisinière à gaz) et un maximum
de 30 po au-dessus de la table de cuisson.
5. Deux installateurs sont recommandés lors de l’installation
vu la grande dimension et le poids de cette hotte.
6. Afin de réduire les risques d’incendie, assurez-vous
d’évacuer l’air à l’extérieur – Ne pas évacuer l’air dans
des espaces restreints comme l’intérieur des murs ou
plafond ou dans le grenier, faux plafond ou garage.
7. Cet appareil est équipé d’un thermostat pouvant
faire démarrer le ventilateur automatiquement. Afin
de réduire le risque de blessure, couper le courant
à partir du panneau électrique et verrouiller ou
apposer un avertissement sur le panneau afin de
prévenir que la hotte soit mise en marche automatiquement.
8. À cause de la grande capacité d’évacuation de
cette hotte, il est recommandé d’ouvrir une fenêtre dans
ou près de la cuisine afin de remplacer l’air évacué.
9. Afin de réduire les risques d’incendie et d’électrocution,
la hotte Broan Elite série 64000 doit être installée
uniquement avec un des ventilateurs intérieurs Broan
suivants : P5 ou P8; un des ventilateurs extérieurs
Broan suivants : 331H, 332H, 335 ou 336 ou un des
ventilateurs en ligne Broan suivants : HLB3, HLB6,
HLB9 ou HLB11 (vendus séparément). Aucun
autre ventilateur ne doit être utilisé.
10. Cette hotte ne doit être utilisée qu’avec un ensemble
de cordon d’alimentation approuvé.
11. Veuillez consulter l’autocollant apposé à l’intérieur de
la hotte pour plus d’information ou autres exigences.
!
!
- 19 -
HL0070
Dosseret Série RMP
(Recouvrement de mur
en acier inoxydable
avec support assiettes)
Adaptateur et volet 3
1
/4 po x 10 po
(fourni avec ventilateurs P5 et P8)
Adaptateur et volet 3
1
/4 po x 14 po
(fourni avec ventilateur P8)
Modèle P5 ventilateur
simple (500 pcm)
Modèle P8 ventilateur double
(900 pcm) pour hottes de
36 po ou plus
NOTE : Le ventilateur double P8 peut être
installé autant avec des conduits
de 3
1
/4 po x 14 po que des conduits
de 3
1
/4 po x 10 po. Pour une
performance optimale au niveau
sonore et de la ventilation, utiliser
des conduits de 3
1
/4 po x 14 po.
Plaque ventilateur fournie
avec ventilateurs P5 et P8
HOTTE SÉRIE 64000
- SYSTÈME DE HOTTE DE CUISINIÈRE SÉRIE 64000 -
VENTILATEURS INTÉRIEURS
Modèle 407
(Conduit de
7 po rond
section
de 2 pi)
Modèle 412
transition
(3
1
/4 po x 10 po à 7 po)
Conduit
standard
3
1
/4 po x 10 po
Conduit
3
1
/4 po x 14 po
Modèle 643
(Capuchon de
mur 8 po rond)
Déviateur d’air (sortie verticale seulement)
(fourni avec les ventilateurs P5 et P8)
Modèle 647
(Capuchon de
mur 7
po rond)
Modèle 634 ou 644
(Capuchon de toit)
Conduit
standard de
8 po rond
Modèle 413 transition
(3
1
/4 po x 10 po à 8 po)
Modèle 459
transition
3
1
/4 po x 14 po à 8 po)
Modèle 415
coude ajustable
7 po rond (optionel)
Coude ajustable
8 po rond (optionel)
- 20 -
HL0071
HOTTE SÉRIE 64000
- SYSTÈME DE HOTTE DE CUISINIÈRE SÉRIE 64000 -
VENTILATEURS EN LIGNE ET EXTÉRIEURS
Dosseret Série RMP
(Recouvrement de mur
en acier inoxydable
avec support assiettes)
Modèle 421
(Volet intérieur
10 po rond vert.)
Recommandé
pour utilisation
avec ventilateurs
extérieurs
Modèle 410
(Conduit de 10 po rond
standard section de 2 pi)
Modèle 418
Coude ajustable de
10 po (optionnel)
Ventilateur en ligne
modèle HLB3 (280 pcm)
(incluant une transition
ronde 8 po à 10 po)
Ventilateur extérieur
modèle 331H (600 pcm)
ou 332H (900 pcm)
Ventilateur extérieur
modèle 335 (1200 pcm)
ou 336 (1500 pcm)
Modèle 441
(Capuchon de
mur 10 po rond)
Modèle 437
(Capuchon de toit haut rendement)
Modèle 441
(Capuchon de
mur 10 po rond)
Plaque ventilateur 332KR pour
ventilateurs extérieurs ou en
ligne. Vendue séparément.
Ventilateur en ligne modèle
HLB6 (600 pcm)
(incluant deux transitions
rondes de 4½ po x 18½ po
à 10 po)
Ventilateur en ligne
modèle HLB9 (800 pcm)
ou HLB11 (1100 pcm)
(incluant deux transitions
rondes de 8 po x 12 po
à 10 po)
- 21 -
1. SÉLECTIONNER L’OPTION VENTILATEUR ET NSTALLER LES CONDUITS
Cette hotte fonctionne autant avec un ventilateur intérieur, en ligne ou extérieur. La hotte de modèle Broan Elite série
64000 doit être installée uniquement avec l’un des ventilateurs suivants : P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H,
335 ou 336 (vendus séparément). Aucun autre ventilateur ne peut être utilisé.
Déterminer à quel endroit et de quelle façon les conduits seront installés.
Si un ventilateur en ligne est installé, se reporter aux directives incluses avec celui-ci et suivre les étapes 1 à
3, 6, 9, 10, 12 et suivantes de ce guide.
Installer des conduits de bonnes dimensions, coude(s) et capuchon de mur ou de toit selon le type de ventilateur. Si des
conduits circulaires de 7 po ou 8 po sont utilisés, utiliser une transition. Se servir de ruban adhésif en toile de 2 po pour
assurer l’étanchéité des joints.
La distance minimale entre le bas de votre hotte et la surface de cuisson ne doit pas être plus petite que 20 po
(24 po d’une cuisinière à gaz). Un maximum de 30 po au-dessus de la surface de cuisson est fortement
recommandé pour une meilleure évacuation des odeurs de cuisine.
Une distance de plus de 30 po demeure à la discrétion de l’installateur et de l’utilisateur.
Hotte avec
ventilateur intérieur
Conduits de
3¼ po x 10 po ou
de 3¼ po x 14 po
Capuchon de toit
Capuchon
de mur
HH0029F
Transition de
3¼ po x 14 po à 8 po
si conduits de
3¼ po x 14 po
Minimum de 20 po
au-dessus de la
table de cuisson
(24 po cuisinière à gaz)
INSTALLATION DE CONDUITS RECTANGULAIRES
AVEC VENTILATEUR INTÉRIEUR
MODÈLE P5 (SIMPLE) OU P8 (DOUBLE)
Hotte
Conduits ronds
de 7 po ou 8 po
Capuchon de toit
Capuchon
de mur
Transition de
3¼ po x 10 po
à 7 po ou 8 po
HH0015F
Minimum de 20 po
au-dessus de la
table de cuisson
(24 po cuisinière à gaz)
INSTALLATION DE CONDUITS CIRCULAIRES DE
7 PO OU 8 PO AVEC VENTILATEUR INTÉRIEUR
MODÈLE P5 (SIMPLE) OU P8 (DOUBLE)
Hotte
Conduits ronds
de 10 po
Ventilateur extérieur
HH0016F
Ventilateur
extérieur
Minimum de 20 po
au-dessus de la
table de cuisson
(24 po cuisinière à gaz)
INSTALLATION TYPIQUE AVEC VENTILATEUR
EXTÉRIEUR MODÈLE 331H, 332H, 335 OU 336
HH0060F
Hotte
Capuchon de toit
Ventilateur
en ligne
Conduits ronds
de 10 po
Minimum de 20 po
au-dessus de la
table de cuisson
(24 po, cuisinière à gaz)
Capuchon
de mur
INSTALLATION TYPIQUE AVEC VENTILATEUR
EN LIGNE MODÈLE HLB3, HLB6, HLB9 OU HLB11
- 22 -
2. PRÉPARER L’INSTALLATION
S’assurer que les items suivants sont inclus :
- Hotte
- Accessoires :
• Filtres
• Sac de pièces incluant:
(4) écrous dentelés, (1) serre-fils, (8) vis 1/2 po à double filets, (2) connecteurs (genre «marette»),
(2) vis 1/2 po standard, (6) vis 3/8 po standard
Pièces vendues séparément :
- Ventilateur interne modèle P5 incluant ventilateur, plaque ventilateur, déviateur et adaptateur 3
1
/4 po x 10 po
- Ventilateur interne modèle P8 incluant ventilateur, plaque ventilateur, déviateur et adaptateur 3
1
/4 po x 10 po
et adaptateur 3
1
/4 po x 14 po
- Ensemble de ventilateur el ligne modèle HLB3, HLB6, HLB9 ou HLB11 (tous incluant la transition)
- Ensemble ventilateur extérieur modèles 331H, 332H, 335 ou 336
- Plaque ventilateur en ligne ou extérieur modèle 332KR (requise pour tous les modèles de ventilateurs en ligne ou extérieurs)
- Ampoules halogènes (120V, 50W, PAR 20)
- Lampes chauffantes (120V, IR 175W, PAR 38)
- Dosseret (optionnel)
- Filtres à chicanes (optionnels)
- Transitions, conduits, coudes, volets, capuchons de mur ou de toit. Consuler les pages 19 et 20 pour la liste
complète des accessoires de ventilation et les numéros de modèle.
NOTE: Si le fond de l’armoire est en retrait, y fixer des baguettes de bois (non incluses) de chaque côté.
Pour une hotte de 30 po de largeur, se servir de deux (2) baguettes de 2 po de largeur, et pour une
hotte plus large, se servir de 4 baguettes, de longueur appropriée. Voir ci-dessous pour la
localisation des baguettes.
3. INSTALLER LE DOSSERET (OPTIONNEL)
Le dosseret doit être installé avant la hotte puisque celle-ci couvre les vis d’installation du dosseret. Afin de pouvoir
installer le dosseret, s’assurer d’avoir 18 po entre le dessous de la hotte et le panneau de contrôle de la cuisinière ou
de la surface de cuisson. (Voir instructions fournies avec le dosseret.)
VENTILATEUR INTÉRIEUR : Suivre toutes les étapes subséquentes de ce guide.
VENTILATEUR EXTÉRIEUR :Voir les instructions fournies avec le ventilateur extérieur et suivre les étapes 6, 10, 12
et suivantes du présent guide.
4. SÉLECTIONNEZ L’OPTION VENTILATEUR (EXTÉRIEUR OU INTÉRIEUR)
HD0079
A
A
B C
LARGEURS LOCALISATIONS
DE HOTTES AB C
30 PO 2 PO S/OS/O
36 PO 2 PO 4
1
/2 PO 4
1
/2 PO
42 PO 2 PO 7
1
/4 PO 8
1
/4 PO
48 PO 4 PO 10
1
/4 PO 11
1
/4 PO
- 23 -
Enlever l’ouverture préamorcée choisie pour la sortie d’air de la hotte (horizontale à l’arrière de la hotte ou verticale
sur la plaque du ventilateur). Voir les photos ci-dessous.
5. CHOISIR L’OUVERTURE (VENTILATEUR INTÉRIEUR)
Retrait de l’ouverture préamorcée à l’arrière de la hotte
HD0076
ATTENTION
Si un ventilateur P5 est installé, enlever l’ouverture préamorcée de 10 po de largeur (la plus
petite). Si un ventilateur P8 est installé, retirer l’ouverture préamorcée de largeur correspondante
aux conduits (10 po ou 14 po).
Retrait de l’ouverture préamorcée sur la plaque du ventilateur
HD0077
Ouverture
de 10 po
Ouverture de 14 po
Ouverture
de 14 po
Ouverture
de 10 po
6. INSTALLER LA PLAQUE VENTILATEUR (TOUS LES VENTILATEURS)
VENTILATEUR INTÉRIEUR : Installer la plaque (incluse avec les ventilateurs P5 et P8) à l’intérieur de la hotte en
utilisant 4 écrous dentelés. Voir la photo ci-dessous.
VENTILATEUR EXTÉRIEUR OU EN LIGNE : Voir les instructions incluses avec l’ensemble de plaque ventilateur de
modèle 332KR (vendu séparément). Installer la plaque à l’intérieur de la
hotte en utilisant 4 écrous dentelés.
HD0042
Insertion du déviateur dans l’ouverture verticale
7. INSTALLER LE DÉVIATEUR (VENTILATEUR INTÉRIEUR)
Si la hotte est installée de façon à évacuer l’air verticalement, le déviateur
doit être installé. Installer le déviateur tel qu’illustré.
NOTE : Il est normal que le déviateur n’entre pas entièrement dans la
hotte, il dépasse d’environ 1/8”.
HD0003
- 24 -
8. INSTALLER L ADAPTATEUR (VENTILATEUR INTÉRIEUR)
En utilisant les 2 vis standard 1/2 po, installer l’adaptateur sur le dessus (ou à l’arrière) de la hotte. Sceller ensuite
l’adaptateur à l’aide de ruban adhésif en toile.
HD0005
HD0006
9. INSTALLER LA HOTTE (TOUS LES VENTILATEURS)
VENTILATEUR INTÉRIEUR : Passer l’alimentation électrique jusqu’à l’endroit de l’installation de la hotte. Placer la
hotte à son emplacement. Marquer la position des vis (petite partie du trou en forme de poire) à l’aide d’un crayon.
Retirer la hotte et installer les 8 vis 1/2 po double filets en laissant un espace de 1/8 po (4 vis pour la hotte de 30 po).
Enlever le couvercle de la boîte électrique et y insérer le serre-fils. Passer le câble électrique dans la hotte et serrer la
vis du serre-fils à l’entrée de la hotte pour maintenir les fils en place. Placer la hotte sous l’armoire (les vis passent à
travers la grosse partie des trous) et glisser la hotte en position. S’assurer que l’adaptateur entre dans le conduit. Visser
complètement les vis pour maintenir la hotte en position.
VENTILATEUR EN LIGNE OU EXTÉRIEUR : Passer l’alimentation électrique jusqu’à l’endroit de l’installation de la
hotte. Placer la hotte à son emplacement. Marquer la position des vis (petite partie du trou en forme de poire) à l’aide
d’un crayon. Retirer la hotte et installer les 8 vis 1/2 po double filet en laissant un espace de 1/8 po (4 vis pour la hotte
de 30 po). Enlever le couvercle de la boîte électrique située sur le dessus de la hotte et effectuer le branchement
électrique (voir les instructions incluses avec le ventilateur en ligne ou extérieur). Placer la hotte sous l’armoire (les vis
passent à travers la grosse partie des trous) et glisser la hotte en position. Visser complètement les vis pour maintenir
la hotte en position.
HD0043
- 25 -
10. BRANCHEMENTS ÉLECTRIQUES (TOUS LES VENTILATEURS)
VENTILATEUR INTÉRIEUR : Connecter les fils à la boîte électrique
en utilisant les connecteurs. Connecter le fil NOIR au NOIR, le BLANC
au BLANC et le VERT ou DÉNUDÉ à la vis de mise à la terre. Refermer
le couvercle. NE PAS OUBLIER DE CONNECTER LA MISE À
LA TERRE.
VENTILATEUR EN LIGNE OU EXTÉRIEUR : Enlever le couvercle de la boîte électrique de la plaque ventilateur et
effectuer le branchement électrique (voir les directives incluses avec le ventilateur en ligne ou extérieur).
1) Vis de mise à la terre
AVERTISSEMENT
Risque d’électrocution. Le raccordement électrique doit être effectué par du personnel qualifié
conformément aux codes et standards. Avant d’effectuer le branchement, coupez l’alimentation
électrique au panneau de service et verrouillez-le pour éviter une mise en marche accidentelle.
!
1
HD0007
11. INSTALLER LE VENTILATEUR (VENTILATEUR INTERNE)
Le ventilateur doit être installé à la plaque ventilateur en utilisant 4 vis 3/8 po pour le ventilateur simple et 6 vis 3/8 po
pour le ventilateur double. Enlever le couvercle du ventilateur. Enlever ensuite la ou les roue(s) du ventilateur en tirant
délicatement (voir photos ci-dessous).
HD0021
HD0022
- 26 -
Installer les vis aux endroits indiqués sur les photos ci-dessous (ventilateur simple ou double) en laissant un espace
d’environ 1/8 po. Accrocher ensuite le ventilateur à la plaque ventilateur (passer les têtes de vis à travers la grande par-
tie des trous). Glisser ensuite le ventilateur en position (les têtes de vis dans la petite partie des trous). Serrer complète-
ment les vis.
HD0044
HD0044
Ventilateur simple (P5)
Ventilateur double (P8)
11. INSTALLER LE VENTILATEUR (VENTILATEUR INTERNE) (SUITE)
AVERTISSEMENT
Ne jamais brancher le fil élecrique du ventilateur à la prise femelle du cordon d’alimentation.
!
Brancher le cordon de la boîte électrique (A) et le ventilateur (B) aux
prises derrière le panneau de contrôle à l’intérieur de la hotte.
HE0003
POUR LE VENTILATEUR DOUBLE,
S’ASSURER QUE LES ROUES SONT
CORRECTEMENT REPLACÉES; LA
HOTTE NE FONCTIONNERA PAS
NORMALEMENT SI INVERSÉES. Les
ventilateurs doubles possèdent deux
roues différentes; une doit tourner dans
le sens des aiguilles d’une montre et
l’autre dans le sens contraire des aiguilles
d’une montre. Chaque roue et moteur
portent une flèche et un numéro, vous
devez les assortir correctement. (Voir
dessin ci-contre
.)
Ventilateur simple (P5)
A
B
Ventilateur double (P8)
Terminer la fixation du ventilateur à l’aide de 2 autres vis aux endroits indiqués sur les photos ci-dessous (ventilateur
simple ou double). Remettre en place la ou les roue(s) de ventilateur et le couvercle.
HD0080
HD0081
21
HD0023
DEVANT
HD0023
1
2
- 27 -
12. AMPOULES HALOGÈNES
Cette hotte de cuisinière utilise des ampoules halogènes de 50W (120V, 50W, PAR 20).
Installer les ampoules en les tournant dans le sens des aiguilles d’une montre.
13. LAMPES CHAUFFANTES
Les lampes chauffantes requises sont des ampoules infrarouges de 175W max. (120V, IR175W, PAR 38).
Vous pouvez utiliser des ampoules halogènes blanches si les tablettes réchauds ne sont pas utilisées (120V, 90W, PAR 38).
Installer les ampoules en les tournant dans le sens horaire.
14. INSTALLER LES FILTRES
Il est recommandé d’installer d’abord les filtres situés aux extrémités et de terminer par le(s) filtre(s) du centre.
INSTALLATION DES FILTRES
1. Insérer la partie supérieure du filtre dans la hotte. (côté de la languette)
2. Faire pivoter la partie inférieure vers l’intérieur de la hotte.
3. Placer le filtre sous l’attache située au fond de la hotte.
4. En tirant sur sa languette, glisser le dessus du filtre sous la pièce de retenue intérieure.
Des filtres à chicanes sont disponibles en option. (Voir la feuille d’installation incluse avec les filtres à chicane.)
1) Languettes
15. ENTRETIEN
Filtres et roue de ventilateur.
Les filtres, la gouttière et la ou les roue(s) de ventilateur doivent être fréquemment nettoyés. Utiliser de l’eau chaude
additionnée de détergent. Les filtres et les roues peuvent être nettoyés au lave-vaisselle.
Pousser les filtres vers l’intérieur de la hotte et les désengager de la gouttière pour ensuite les retirer de la hotte.
HD0009
HD0010
1
- 28 -
15. ENTRETIEN (SUITE)
Nettoyage de la hotte
Acier inoxydable : Comment maintenir son apparence étincelante
À faire :
- Laver régulièrement les surfaces à l’aide d’un chiffon ou linge propre imbibé d’eau tiède et de savon doux ou
détergent à vaisselle.
- Toujours nettoyer dans la direction des lignes de grains (direction du polissage).
- Toujours bien rincer avec de l’eau propre (2 ou 3 fois) après le nettoyage et essuyer complètement.
- Un nettoyant domestique conçu spécialement pour l'acier inoxydable peut aussi être utilisé.
À ne pas faire :
- N’utiliser aucune laine d’acier ou d’acier inoxydable ou tout autre grattoir pour enlever la saleté tenace.
- N’utiliser aucune poudre nettoyante abrasive ou rugueuse.
- Ne pas laisser la saleté s’accumuler.
- Ne pas laisser la poussière de plâtre ou tout autre résidu de construction/rénovation atteindre la hotte.
Couvrir la hotte pour la durée des travaux pour s’assurer qu’aucune poussière ne colle à la surface de l’acier.
À éviter lors du choix d’un détergent :
- Tous produits nettoyants qui contiennent des agents de blanchiment; ils attaqueront l’acier inoxydable.
- Tous produits contenant du chlorure, fluorure, iode ou bromure; ils détérioreront rapidement les surfaces.
- Tous produits combustibles utilisés pour le nettoyage : acétone, alcool, éther, benzol, etc.; ils sont hautement
explosifs et ne devraient jamais être utilisés près d’une cuisinière.
Surfaces peintes :
Nettoyer avec de l’eau chaude additionnée seulement d’un détergent doux. S’il y a décoloration, utiliser une bonne cire à
peinture telle qu’une cire d’automobile. (NE PAS UTILISER de nettoyant abrasif rugueux ou de nettoyant à porcelaine.)
16. FONCTIONNEMENT
Toujours mettre en marche la hotte avant de commencer la cuisson afin d’établir une circulation d’air dans la cuisine.
Laisser également la hotte fonctionner quelques minutes après l’arrêt de la cuisinière afin de nettoyer l’air. Ceci aidera
à garder la cuisine plus propre et plus claire.
1
1
2
3
4
1) Interrupteurs des lampes chauffantes
2) Interrupteurs des ampoules halogènes
3) MARCHE/ARRÊT du ventilateur
4) Contrôle de la vitesse du ventilateur
HC0028
VENTILATEUR
Le ventilateur fonctionne à l’aide de deux contrôles.
Utiliser l’interrupteur marche/arrêt muni d’une lumière rouge pour mettre en marche et arrêter le ventilateur. Lorsque
mis sous tension, le ventilateur fonctionnera à la vitesse utilisée la dernière fois.
Utiliser le contrôle de vitesse du ventilateur en tournant dans le sens des aiguilles d’une montre pour diminuer la
vitesse et dans le sens contraire des aiguilles d’une montre pour augmenter la vitesse.
AMPOULES HALOGÈNES
Deux interrupteurs marche/arrêt contrôlent les lampes halogènes.
L’interrupteur à bascule avant contrôle la lampe du centre (pour les hottes de 42 po et 48 po). L’interrupteur arrière
contrôle les ampoules de chaque côté (chaque interrupteur contrôle une ampoule pour les hottes de 30 po et 36 po).
Allumer une, deux ou trois ampoules selon vos besoins. Utiliser des ampoules halogènes PAR 20, 50W.
- 29 -
LAMPES CHAUFFANTES (INFRAROUGES)
Chaque lampe est contrôlée indépendamment par son propre interrupteur. Utiliser des ampoules infrarouges (120V,
IR175W, PAR38) ou des ampoules halogènes (120V, 90W, PAR38) si les tablettes servant au chaud d’aliments ne sont
pas utilisées.
HEAT SENTRY
Votre hotte est équipée d’un capteur de température appelé Heat Sentry. Ce capteur actionnera automatiquement le
ventilateur de la hotte ou augmentera sa vitesse s’il détecte de la chaleur excessive au-dessus de la surface de cuisson.
1) Si le ventilateur n’est pas en marche – il met le ventilateur en marche à haute vitesse.
2) Si le ventilateur est en marche à une vitesse inférieure – il met le ventilateur à vitesse maximum.
Lorsque la température revient à la normale, la vitesse du ventilateur retourne à sa position originale.
AVERTISSEMENT
Le HEAT SENTRY peut entrer en fonction même si la hotte est arrêtée. Dans ce cas, il est
impossible d’arrêter le ventilateur avec son interrupteur. Si vous devez arrêter la hotte, faites-le à
partir du panneau électrique principal.
!
AVERTISSEMENT
Ne jamais placer de matière inflammable sous les lampes chauffantes.
!
16. FONCTIONNEMENT (SUITE)
GARANTIE
GARANTIE LIMITÉE D’UN AN DE BROAN-NUTONE LLC
Broan-NuTone LLC garantit à l’acheteur consommateur initial de ses produits qu’ils sont exempts de tout défaut
dans les matières premières ou la main-d’œuvre, pour une période d’un an à compter de la date d’achat par le
consommateur initial. IL N’Y A PAS D’AUTRES GARANTIES, EXPRIMÉES OU IMPLICITES, INCLUANT, MAIS
NON LIMITÉES AUX GARANTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE
DANS UN BUT PARTICULIER.
Durant cette période d’un an, Broan-NuTone LLC, à sa discrétion, réparera ou remplacera gratuitement, tout
produit ou pièce qui s’avère défectueux et ayant été utilisé nomalement et d'une manière non abusive.
Cette garantie ne couvre pas (a) l’entretien et le service normal ou (b) tout produit ou pièce endommagé par suite
de mauvais usage, négligence, accident, entretien inapproprié ou réparation (autre que par Broan-NuTone LLC),
mauvaise installation ou installation non conforme au mode d’installation recommandé.
La durée de toute garantie implicite est limitée à une période d’un an tel que spécifiée pour la garantie exprimée.
Certains états ou provinces ne permettent pas de limite de temps sur les garanties implicites. Si tel est le cas,
veuillez ne pas tenir compte de la dernière limite décrite ci-dessus.
L’ENGAGEMENT DE BROAN-NUTONE LLC DE RÉPARER OU DE REMPLACER, AU CHOIX DE BROAN-
NUTONE LLC, SERA LA SEULE OBLIGATION EXCLUSIVE SOUS CETTE GARANTIE. BROAN-NUTONE LLC
NE SE TIENDRA PAS RESPONSABLE DES DOMMAGES DIRECTS, INDIRECTS OU SPÉCIAUX
SURVENANT À CAUSE DE OU EN RAPPORT À L’UTILISATION OU LA PERFORMANCE DE SES PRODUITS.
Certains états ou provinces ne permettent pas l’exclusion ou la limite relative aux dommages directs, indirects
ou spéciaux. Si tel est le cas, veuillez ne pas tenir compte de l’exclusion ou de la limite ci-dessus.
Cette garantie vous donne des droits légaux spécifiques et il se peut que vous ayez d’autres droits qui varient
d’un état ou d’une province à l’autre. Cette garantie annule toutes les autres garanties précédentes.
Pour le service sous garantie, vous devez (a) aviser Broan-NuTone LLC à l’une des adresses ou numéros de
téléphone mentionnés plus bas, (b) donner le numéro du modèle et l’identification de la pièce et (c) décrire la
nature de tout défaut dans le produit ou la pièce. Au moment de la demande de service sous garantie, vous devez
présenter une preuve de la date d’achat initial du dit produit.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)
- 30 -
28 910112
8
17
17
17
5
6
14
12
13
7
15
16
4
3
20
19
17
2
2
17
18
1
HL0002
PIÈCES DE REMPLACEMENT
Série 64000
DE LA QTÉ (largeur de hotte)
REF. PIÈCE
DESCRIPTION
30 po 36 po 42 po 48po
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
V06750
V02264
V02773
V02772
V03435
V03436
V03501
V03507
V03502
V03503
V03504
V03505
V03517
V03518
V03519
V03520
V00673
V02512
V01869
V01582
V00606
V03509
V03510
V13216
V13217
V13218
V13219
V03686
V02544
V03598
V03515
V13278
LOGO BROAN ELITE
DOUILLE
CONNECTEUR MÂLE
CONNECTEUR FEMELLE
THERMOSTAT
SUPPORT POUR THERMOSTAT
CONTRÔLE DE VITESSE
INTERRUPTEUR SIMPLE UPST POUR LAMPE CHAUFFANTE
INTERRUPTEUR DOUBLE UPST POUR LAMPES HALOGÈNES
INTERRUPTEUR SIMPLE ILLUMINÉ UPST POUR VENTILATEUR
BOUTON DE CONTRÔLE DE VITESSE
PLAQUE À BORNES
FILS D’ALIMENTATION 10 po
FILS LAMPES RÉCHAUD 10 po
FIL DE CONTRÔLE 10 po
FIL INTERRUPTEUR ILLUMINÉ 10 po
ÉCROU DENTELÉ N° 8-32
VIS N° 8-32 x 1/2 po QUADREX
VIS MÉCANIQUE N°6-32 x
1
/4 po
ÉCROU DENTELÉ N°6-32
VIS N° 8- 3/8 poT/B TÊTE N°8
FILTRE RANGEMASTER 8,930
po
x 9,800 po
FILTRE RANGEMASTER 11,930
po
x 9,800
po
GOUTTIÈRE 30 po
GOUTTIÈRE 36 po
GOUTTIÈRE 42 po
GOUTTIÈRE 48 po
ATTACHE FILTRE
AMPOULE HALOGÈNE PAR 20 50 W
LAMPE CHAUFFANTE
GUIDE D’INSTALLATION
SAC D’INSTALLATION ((4) écrous à bride n° 10-32, (1) serre-fil LP16-AP, (2) connecteurs n° 74B,
(8) vis double filets 6-12 x 0,5 po, (6) vis n°8 x 3/8 po, (2) vis n°6 x 1/2 po)
1
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
2
1
1
-
-
-
3
2
2
1
1
1
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
-
3
-
1
-
-
3
2
2
1
1
1
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
2
2
-
-
1
-
4
3
2
1
1
1
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
-
4
-
-
-
1
4
3
2
1
1
- 31 -
PIÈCES DE REMPLACEMENT
DE
RÉF. LA PIÈCE
DESCRIPTION QTÉ
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
V13296
V03500
V12997
V03577
V02160
V01869
V01857
V01582
V14973
V01810
V03400
V01766
V00871
V02001
V01831
V11705
V11614
V01927
V03495
V03494
V13230
V03496
V00660
V05520
V00613
1
1
1
1
1
4
1
1
1
3
1
1
3
3
2
1
1
4
1
1
1
1
1
2
2
ADAPTATEUR ET VOLET 3
1
/4 po x 10 po
DÉFLECTEUR D’AIR
PLAQUE VENTILATEUR SIMPLE ASSEMBLÉE
MOUSSE 1/2 po x 1/2 po x 12 po
CONDENSATEUR 15MFD
VIS MÉCANIQUE N° 6-32 x 1/4 po
CACHE-FILS
ÉCROU DENTELÉ N° 6-32
VENTILATEUR SIMPLE ASSEMBLÉ
ANNEAU ROUE
ROUE HOTTE 7,09 po x 3,37 po CW
MOTEUR 165W CW
RONDELLE 3/16 po DI x 3/4 po DE
OEILLET MOTEUR G-431-1
COLLIER DE SERRAGE 8 po
SUPPORT DE MOTEUR
FIL N° 18 TEW BRUN x 10 po
VIS MÉTRIQUE M4 x 6mm PAN QDRX
ARRÊT DE TRACTION CORDON VENTILATEUR
CORDON D’ALIMENTATION VENTILATEUR 36 po
PORTE CONNEXION ÉLECTRIQUE
CORDON D’ALIMENTATION 120 VOLTS
ARRÊT DE TRACTION CORDON D’ALIMENTATION
VIS N° 8 x 3/8 po, T/B, TÊTE N° 8
VIS N°10-32 x 3/8 po, TF, VERTE
PLAQUE ET VENTILATEUR SIMPLE
(Modèle P5)
HL0021
19
21
18
17
20
22
2
3
23
4
1
9
6
8
5
15
14
13
6
16
12
7
11
10
- 32 -
PIÈCES DE REMPLACEMENT
DE
RÉF. LA PIÈCE
DESCRIPTION QT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
V14971
V13296
V03500
V14975
V03577
V01582
V02160
V01857
V01766
V03400
V14974
V01810
V03399
V03457
V00871
V01831
V11705
V11614
V02001
V01927
V03495
V03494
V14960
V00660
V03496
V0520
V00613
1
1
1
1
1
1
2
2
1
1
1
2
1
1
6
2
2
2
6
8
1
1
1
1
1
4
2
ADAPTATEUR ET VOLET 3
1
/4 po x 14 po
ADAPTATEUR ET VOLET 3
1
/4 po x 10 po
DÉFLECTEUR D’AIR
PLAQUE VENTILATEUR DOUBLE ASSEMBLÉE
MOUSSE 1/2 po x 1/2 po x 12 po
ÉCROU DENTELÉ N
O
6-32
CONDENSATEUR 15MFD
CACHE-FILS
MOTEUR 165W CW
ROUE HOTTE 7,094 po x 3,375 po CW
VENTILATEUR DOUBLE ASSEMBLÉ
ANNEAU ROUE
ROUE HOTTE 7,094 po x 3,375 po CCW
MOTEUR 165W CCW
RONDELLE 3/16 po DI x 3/4 po DE
COLLIER DE SERRAGE 8 po
SUPPORT DE MOTEUR
FIL N° 18 TEW BRUN X 10 po
OEILLET MOTEUR G-431-1
VIS MÉTRIQUE M4 x 6mm PAN QDRX
ARRÊT DE TRACTION CORDON DE VENTILATEUR
CORDON D’ALIMENTATION VENTILATEUR 36 po
PORTE CONNEXION ÉLECTRIQUE
ARRÊT DE TRACTION CORDON D’ALIMENTATION
CORDON D’ALIMENTATION 120 VOLTS
VIS N° 8 X 3/8”, T/B, TÊTE N°8
VIS N° 10-32 X 3/8, TF, VERTE
21
22
23
2
3
20
24
25
1
19
18
17
16
15
13
6
9
10
11
12
14
4
5
7
8
PLAQUE ET VENTILATEUR DOUBLE
(Modèle P8)
MANUAL DE INSTALACIÓN
SERIE 64000
CONCEBIDO SÓLO PARA USO DOMÉSTICO
INSTALADOR: DEJAR ESTE MANUAL AL PROPRIETARIO.
PROPIETARIO: INSTRUCCIONES DE UTILIZACIÓN Y MANTENIMIENTO EN LAS
PÁGINAS 43 A 45
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)
REGISTRE SU PRODUCTO EN LÍNEA EN: www.broan.com/register
V03515 rev. J
HB0056
LEER Y CONSERVAR ESTAS INSTRUCCIONES
!
!
- 34 -
ADVERTENCIA ADVERTENCIA
PARA REDUCIR EL RIESGO DE INCENDIO,
DESCARGA ELÉCTRICA, O LESIONES A
PERSONAS, CUMPLA LOS SIGUIENTES PUNTOS:
1. Solamente use esta unidad de la manera propuesta
por el fabricante. Si tiene alguna pregunta, comuniquese
con el fabricante en la dirección o teléfono anotados
en la garantía.
2. Antes de limpiar o poner en servicio la unidad,
apague el interruptor en el panel de servicio, y
asegure el panel de servicio para evitar que se
encienda accidentalmente. Cuando el dispositivo
para desconectar el servicio eléctrico no puede ser
cerrado con algún tipo de traba, sujete fuertemente
al panel de servicio, una etiqueta de advertencia
prominente.
3. El trabajo de instalación y el alambrado eléctrico
deben llevarse a cabo por personal calificado de
acuerdo con todos los códigos y las normas aplicables,
incluyendo los códigos y normas de construcción
contra incendios.
4. Se requiere una cantidad de aire suficiente para la
combustión y escape de gases por la chimenea
del equipo de quemado de combustible para evitar
salirse de las especificaciones y estándares de
seguridad del fabricante, tales como los publicados
por la Asociación nacional de protección contra
incendios (NFPA por sus siglas en Inglés), y la
Sociedad americana de ingenieros de calefacción,
refrigeración y aire acondicionado (ASHRAE por
sus siglas en Inglés), y los códigos de las
autoridades locales.
5. Cuando corte o taladre en una pared o techo, no
dañe los cables eléctricos ni otras instalaciones
ocultas.
6. Los ventiladores con conductos deben siempre
ventilar hacia el exterior.
7. No use esta unidad con ningún
otro
control de
velocidad de estado sólido.
8. Para reducir todo riesgo de incendio, use solamente
conductos en metal.
9. Esta unidad se debe conectar a tierra.
PARA REDUCIR EL RIESGO DE INCENDIO DE
GRASA EN LA SUPERFICIE DE LA ESTUFA:
a) No deje nunca los aparatos de cocer sin vigilancia
a fuego vivo. Los desbordamientos producen humo
y derrames grasiendos que pueden inflamarse.
Caliente el aceite despacio, a fuego lento o mediano.
b) Ponga en marcha siempre la campana al cocinar a
temperaturas elevadas o al cocinar alimentos
flameados.
c) Limpie los ventiladores con frecuencia. No deje
que la grasa se acumule en el ventilador ni en el filtro.
d) Utilice cacerolas de tamaño apropiado. Emplee
siempre un recipiente adecuado para el tamaño de
la placa.
PARA EVITAR RIESGO DE LESIONES PERSONALES
EN CASO DE INCENDIO DE GRASA EN LA SUPERFICIE
DE LA ESTUFA, OBSERVE LO SIGUIENTE*:
1. Cubra y sofoque las llamas con una tapa ajustada,
azafate de hornear galletas, o azafate de metal, y
luego apague el calentador. TENGA CUIDADO
PARA EVITAR QUEMADURAS. Si la llamas no se
apagan inmediatamente, HAY QUE EVACUAR Y
LLAMAR LOS BOMBEROS.
2. NUNCA ALCE UNA SARTÉN QUE TENGA
LLAMAS – Usted se puede quemarse.
3. NO USE AGUA, incluyendo trapos, lavaplatos
mojados o toallas - puede que ocurran explosiones
de vapor violentas.
4. Use un extintor SOLAMENTE si :
A. Usted sabe que tiene un extintor ABC y sabe usarlo.
B. El incendio es pequeño y está restringido al
área donde empezó.
C. Se está llamando los bomberos.
D. Usted puede tratar de apagar el fuego teniendo
una salida detrás suyo.
* Basado en “Kitchen Fire Safety Tips” publicado por la
Asociación National de protección contra Incendios (NFPA).
PRECAUCIÓN
1. Sólo para uso de ventilación general. No se use para
extraer materiales o vapores peligrosos o explosivos.
2. Para evitar daños al cojinete del motor y/o impulsores
ruidosos o desequilibrados, mantenga la fuente de potencia
lejos de rocíos de pared seca, de polvo de construcción, etc.
3. El motor de la campana tiene un dispositivo contra
sobrecargas térmicas que apaga el motor en forma
automática si éste se sobrecalienta. El motor
volverá arrancar cuando se enfríe. Si el motor sigue
apagándose, haga verificar campana reciba servicio.
4. Para lograr una mejor captura de las impurezas producidas
al cocinar, la parte inferior de la campana deberá estar
a un mínimo de 20” (24” de una cocina a gas) y un
máximo de 30” sobre el nivel la superficie para cocina.
5. Se recomienda que la instalación la realicen dos
personas, debido al tamaño y peso de esta campana.
6. A fin de reducir los riesgos de incendio y para bien
evacuar el aire de salida, asegúrese de evacuar el
aire al exterior – No evacue el aire en espacios limitados
como el interior de las paredes o del techo o en el
desván, falso techo o garaje.
7. Este producto está equipado de un termostato que
puede hacer partir el ventilador automáticamente.
Para evitar los riesgos de daño, apague la corriente
del panel eléctrico y cierre con candado o afiche
una advertancia en el panel para prevenir que la
campana funcione automáticamente.
8. A causa de la gran capacidad de evacuación de esta
campana, usted debe asegurarse que suficiente
aire entre en la casa para remplazar el aire evacuado
abriendo una ventana a el interior o cerca de la
cocina por ejemplo.
9. Para reducir el riesgo de incendio y descarga eléctrica,
este campana Broan Elite serie 64000 debe ser
instalada con ventilador interior modelo P5 o P8,
ventilador exterior modelo 331H, 332H, 335 o 336 o
ventilador en línea HLB3, HLB6, HLB9 o HLB11
(vendidos separadamente) solamente. Otros ventiladores
no pueden reemplazar a este ventiladores.
10. Utilíce sólo con un conjunto autorizado de conexión
con cordón.
11. Lea la etiqueta de especificaciones en el producto
para mayor información y requisitos.
!
!
- 35 -
Conducto
estándar
3
1
/4” x 10”
Modelo P8
ventilador doble (900 pcm) para
campanas de 36’ o más anchas
NOTA: El ventilador doble P8 puede ser
instalado con conductos de
3
1
/4 x 14’’ o 3
1
/4 x 10”. Para
prestaciones óptima a nivel de
sonido y del aire, utilizar los
conductos
3
1
/4 x 14”.
HL0070
CAMPANA
SERIE 64000
- SERIE 64000 SISTEMA DE LA CAMPANA DE COCINA -
VENTILADORES INTERIORES
Placa antisalpicaduras
Serie RMP
(Cubierta para pared
de acero inoxidable con
estantes para
calentamiento.
Opcional.)
Modelo P5
ventilador simple
(500 pcm)
Modelo 407
conducto redondo
de 7” (Sectiones
de 24’’)
Modelo 412
transicíon
3
1
/4” x 10” a 7”
Modelo 647
7” redondo
(remate de pared)
Modelo 415
Codo ajustado
de 7” (opcional)
Adaptador & compuerta 3
1
/4” x 10”
(incluye con ventiladores P5 y P8)
Adaptador & compuerta 3
1
/4” x 14”
(incluye con ventilador P8)
Bandeja de conexión
(incluye el ventiladores
interiores P5 y P8)
Modelo 643
(remate de pared 8”
redondo)
Deflertor de aire
(incluye con ventiladores P5 y P8)
Modelo 634 ó 644
(remate de techo)
Conducto
estándar de
8” redondo
Modelo 413
transicíon
(
3
1
/4” x 10” a 8”)
Codo ajustado de
8” (opcional)
Modelo 459
transicíon
(3
1
/4” x 14” a 8”)
Conducto
3
1
/4” x 14”
- 36 -
HL0071
CAMPANA
SERIE 64000
- SERIE 64000 SISTEMA DE LA CAMPANA DE COCINA -
VENTILADORES EN LÍNEA Y EXTERIORES
Modelo 421
(10” Redondo.
vertical, en
línea interior)
Recomandado
para utilización
con ventiladores
exteriores
Modelo 410 conducto
de 10” redondo
(
Sectiones de 2)
Modelo 418
Codo ajustado de
10” (opcional)
Ventilador en línea
modelo HLB3 (280 pcm)
(incluye una transición
redonda de 8
a 10)
Ventilador exterior
modelo 331H (600 pcm)
ó 332H (900 pcm)
Ventilador exterior
modelo 335 (1200 pcm)
ó 336 (1500 pcm)
Modelo 441
(
Remate de pared
10redondo)
Modelo 437
(Remate de techo alta capacidad)
Modelo 441
(
Remate de pared
10redondo)
Bandeja de conexión
332KR para ventiladores
exteriores
ó en línea.
Vendida separadamente.
Ventilador en línea
modelo HLB6 (600 pcm)
(incluye dos transiciones
redondas de
x 18½ a 10)
Ventilador en línea
modelo HLB9 (800 pcm)
ó HLB11 (1100 pcm)
(incluye dos transiciones
redondas de 8
x 12 a 10)
Placa antisalpicaduras
Serie RMP
(Cubierta para pared
de acero inoxidable con
estantes para
calentamiento.
Opcional.)
- 37 -
1. SELECCIONE LA OPCIÓN VENTILADOR Y INSTALE LOS CONDUCTOS
Campana con
ventilador interior
de 3¼” x 10” o
de 3¼” x 14”
Tapa del techo
Tapa
del muro
HH0029E
Transición de
conducto de 3¼” x 14”
3¼” x 14” a 8” si
Conducto estándar
Distancia mínima de 20
sobre el nivel de la
superficie para cocinar
(24’’ para cocina a gaz)
INSTALACIÓN CON CONDUCTO RECTANGULAR
CON VENTILADOR INTERIOR
MODELO P5 (SIMPLE) Ó P8 (DOBLE)
Campana
Conducto redondo
7 o 8”
Tapa del techo
Tapa
del
muro
Transición
3¼ x 10
a 7 o 8”
HH0015E
Distancia mínima de 20
sobre el nivel de la
superficie para cocinar
(24’’ para cocina a gaz)
INSTALACIÓN CON CONDUCTO REDONDO DE
7 Ó 8 CON VENTILADOR INTERIOR
MODELO P5 (SIMPLE) Ó P8 (DOBLE)
Campana
Conducto
redondo 10
Ventilador exterior
HH0016E
Ventilador
exterior
Distancia mínima de 20
sobre el nivel de la
superficie para cocinar
(24’’ para cocina a gaz)
INSTALACIÓN ESTÁNDAR CON VENTILADOR
EXTERIOR MODELO 331H, 332H, 335 Ó 336
HH0060E
Distancia mínima de 20
sobre el nivel de la
superficie para cocinar
(24’’ para cocina a gaz)
Tapa
del techo
Campana
Ventilador
en línea
Conducto redondo
de 10
Tapa
del
muro
INSTALACIÓN ESTÁNDAR CON VENTILADOR
EN LÍNEA MODELO HLB3, HLB6, HLB9 Ó HLB11
Esta campana funciona tanto con un ventilador exterior, con un ventilador en línea y como interior. La campana de
modelo Broan Elite serie 64000 debe ser instalado unicamente con ventilador modelo P5, P8, HLB3, HLB6, HLB9, HLB11,
331H, 332H, 335 o 336 (vendidos separadamentes). Otros ventiladores no pueden reemplazar a este ventiladores.
Planifique dónde y como se van a colocar los conductos.
Si un ventilador en línea est instalado, se refiere a las instrucciones incluidas con ésté y siga las etapas 1 a
3, 6, 9, 12 y siguiente de este manual.
Instale los conductos de dimensión adecuada, codo(s) y remate la pared o el techo adecuado para el tipo de ventilador
que esté usando. Si usted elige conductos circulares de 7” ó 8”, utilice una transición. Utilice cinta adhesiva a conducto
para asegurarse estanquidad de las coyunturas.
La distancia mínima entre la campana y la encimera debe ser de 20” (24’ para una cocina a gas). Asimismo,
se recomienda que dicha distancia so supere las 30’ para obtener la máxima capacidad de absorción de las
impurezas creadas al cocinar.
Si se utilizan distancias superiores a 30”, el instalador y el usuario son responsables de los posibles problemas.
- 38 -
2. PREPARE LA INSTALACIÓN
Asegúrese que los artículos siguientes están incluidos:
- Campana
- Accesorios:
• Filtros
• Bolsa de piezas incluye:
(4) tuercas dentellado, (1) alambre eléctrico, (8) 1/2” tornillos a doble hilillo (2) conectador de cable,
(2) 1/2” tornillos estàndar, (6) 3/8” tornillos
Piezas separadas:
- Ventilador interno modelo P5 incluye ventilador interno, placa del ventilador, desviador y adaptador 3
1
/4” x 10”
- Ventilador interno modelo P8 incluye ventilador interno, placa del ventilador, desviador y adaptador 3
1
/4” x 10”
y adaptador 3
1
/4” x 14”
- Ventilador exterior 331H, 332H, 335 o 336
- Ventilador en línea modelo HLB3, HLB6, HLB9 o HLB11 (todos con la transición)
- Placa del ventilador modelo 332KR (requerida para todo los ventiladores en línea y exteriores)
- Bombillas halógenas (120V, 50W, PAR 20)
- Lámpara termogéna (120V, IR 175W, PAR 38)
- Placa para salpicadura (opcional)
- Transiciónes, conductos, codos, compuertas de tiro, remates de pared o de techo. Consultar las páginas 35 y 36
para la lista completa de los accessorios de ventilation y los números de modelo.
NOTA: Si el fondo del armario está empotrado, fije los listones de madera (no incluidos) en cada lados tal como
ilustrado abajo. Servirse de dos (2) listones de 2’ de anchura para campana de 30’ de anchura, y de cuatro (4)
listones de 2’ de anchura para campana más ancha, de largo apropiado. Vea abajo por el lugar de los listones.
3. INSTALE LA PLACA PARA SALPICADURAS (OPCIONAL)
La placa para salpicaduras se debe instalar antes que la campana debido a que éste cubre los tornillos de montaje de
la placa para salpicaduras. Para instalar la placa de salpicadura, asegúrese de tener 18’ entre debajo de la campana
y el panel de control de la cocina o encima de la cocina. (Vea las instrucciones incluidas con la placa salpicaduras.)
4. SELECCIONE LA OPCIÓN VENTILADOR (EXTERIOR O INTERIOR)
VENTILADOR INTERIOR: Siga todas las etapas subsecuentes de este manual.
VENTILADOR EXTERIOR: Se refiere a las instrucciones inclidas con el ventilador exterior. Siga las etapas 6, 10, 12
y siguiente del presente manual.
HD0079
A
A
B C
ANCHURA LUGAR
DE CAMPANA ABC
30’ 2’ N/AN/A
36’ 2’ 4
1
/2’’ 4
1
/2’’
42’ 2’ 7
1
/4’’ 8
1
/4’’
48’ 4’ 10
1
/4’’ 11
1
/4’’
- 39 -
5. ELIJA LA ABERTURA (VENTILADOR INTERIOR)
Rompa la abertura elegida (horizontal detrás de la campana o vertical en la placa del ventilador) de salida de aire
.
V
er
las fotos de abajo
.
Rompación de la abertura horizontal detrás de la campana
HD0076
PRECAUCIÓN
Si un ventilador P5 es instalado, quite la abertura de 10’’ de anchura (la mas pequeña). Si un ventilador
P8 es instalado, quite la abertura de dimensión correspondiente a los conductos (10’’ o 14’’).
Rompación de la abertura vertical en la placa del ventilador
HD0077
Abertura de 10’’
Abertura de 14’’
Abertura
de 14’
Abertura
de 10’
6. INSTALE LA PLACA DEL VENTILADOR (TODOS LOS VENTILADORES)
VENTILADOR INTERIOR: Instalar la placa (incluye con el ventilador interior P5 y P8) al interior de la campana utilizando
4 tuercas dentelladas. Vea photo abajo.
VENTILADOR EN LÍNEA O EXTERIOR: Comprar el Modelo 332KR separadamente. Referirse a los instrucciónes incluye
con el conjunto de la placa del ventilador. Instalar la placa al interior de la campana
utilizando
4 tuercas dentelladas.
Inserción del desviador en la campana
HD0042
7. INSTALE EL DEFLECTOR DE AIRE (VENTILADOR INTERIOR)
USTED DEBE también instalar el deflector de aire si usted elige la abertura
vertical. Instale el desviador tal como ilustrado.
NOTA: El deflector no entra completamente en la campana, fíjese que sobre
sale de 1/8”.
HD0003
- 40 -
8. INSTALE EL ADAPTADOR (VENTILADOR INTERIOR
Utilizando los dos (2) tornillos estandar 1/2’’, instale el adaptador encima o detrás de la campana. Luego selle el adaptador
con la ayuda de una cinta adhesiva a conducto.
HD0005
HD0006
9. INSTALE LA CAMPANA (TODOS LOS VENTILADORES)
VENTILADOR INTERIOR: Pase la alimentación eléctrica hasta el lugar de la instalación de la campana. Coloque la campana
en su posición. Con la ayuda de un lápiz marque la posición de los tornillos (pequeña parte del hoyo en forma de pera) retire
la campana e instale los 8 tornillos de 1/2’ doble hilillo dejando un espacio de 1/8’ (4 tornillos para la campana de 30’’). Saque
la tapa de la caja eléctrica, inserte el alambre eléctrico. Pase el cable eléctrico en la campana y apriete el tornillo del alam-
bre eléctrico en la entrada de la campana para mantener los cables en su posición. Coloque la campana debajo del armario
(los tornillos pasan a través de la parte grande de los hoyos) y deslice la campana en su posición. Asegúrese que adapta-
dor entre en el conducto. Atornille completamente los tornillos para que la campana se mantenga en su posición.
VENTILADOR EN LÍNEA O EXTERIOR: Pase la alimentación eléctrica hasta el lugar de la instalación de la campana.
Coloque la campana en su posición. Con la ayuda de un lápiz marque la posición de los tornillos (pequeña parte del hoyo
en forma de pera) retire la campana e instale los 8 tornillos de 1/2’ doble hilillo dejando un espacio de 1/8’ (4 tornillos para
la campana de 30’’). Saque la tapa de la caja eléctrica en encima de la campana y conecte los cables (vea instruciones
incluye con el ventilador exterior). Coloque la campana debajo del armario (los tornillos pasan a través de la parte grande
de los hoyos) y deslice la campana en su posición. Atornille completamente los tornillos para que la campana se mantenga
en su posición.
HD0043
- 41 -
10. CONEXIÓN ELÉCTRICA (TODOS LOS VENTILADORES)
VENTILADOR INTERIOR: Conecte los cables a la caja eléctrica utilizando
los conectadores de cables. Conecte el cable NEGRO al NEGRO, el
BLANCO al BLANCO y el VERDE o desnudo al el tornillo que toma de
tierra. Reemplace la tapa. JAMÁS DEBE OLVIDARSE DE CONECTAR
LA TOMA DE TIERRA.
VENTILADOR EN LÍNEA O EXTERIOR: Saque la tapa de la caja eléctrica de la bandeja de conexión y conecte los
cables (vea instrucciones incluye con el ventilador en línea o exterior).
1) Tornillo que toma de tierra
ADVERTENCIA
Peligro de choque eléctrico. La instalación eléctrica debe ser hecha por personal calificado de acuerdo
con todos los códigos aplicables y normas. Antes de efectuar el empalme, cortar la alimentación
eléctrica del interruptor y cerrar con securidad para prevenir una alimentación accidental.
!
1
HD0007
11. INSTALACIÓN DEL VENTILADOR (INTERIOR)
El ventilador debe ser instalado a la placa del ventilador utilizando 4 tornillos de 3/8’ para el ventilador simple y 6 tornillos
de 3/8’ para el ventilador doble. Saque la tapa del ventilador. Saque la o las rueda(s) del ventilador tirándola delicadamente
(ver fotos de abajo).
HD0021
HD0022
- 42 -
11. INSTALACIÓN DEL VENTILADOR (INTERIOR) (CONTINUACIÓN)
Instale los tornillos en el lugar que indica la foto de abajo (ventilador simple o doble) dejando un espacio de mas o
menos 1/8”. Enganche en seguida el ventilador a la placa del ventilador (pase las cabezas de los tornillos a través de
la parte grandedel hoyo). En seguida resbale el ventilador en su posición (las cabezas de los tornillos a través de la
parte pequeña del hoyo). Atornillar los tornillos completamente.
HD0044
HD0044
Ventilador simple (P5)
Ventilador doble (P8)
ADVERTENCIA
Jamás conecte el cable eléctrico del ventilador con el enchufe del cable de alimentación.
!
Conecte el cable de la caja eléctrica (A) y el cable del ventilador (B)
a los enchufes detrás del panel de control al interior de la campana.
HE0003
PARA EL VENTILADOR DOBLE,
ASEGURÉSE QUE LAS RUEDAS SEAN
BIEN REEMPLAZADAS, LA CAMPANA
NO FUNCIONARÁ NORMALMENTE SI
ESTÁ AL RÉVES. Las dos ruedas del
ventilador son diferentes en el caso de
un ventilador doble, una debe girar en el
sentido de las agujas del reloj y la otra
en el sentido contrario de las agujas del
reloj. Cada rueda y motor tiene una
flecha y un número, usted debe juntarlos
correctamente. (Ver dibujo al lado.)
Ventilador simple (P5)
A
B
Ventilador doble (P8)
Terminar la fijación del ventilador con 2 otros tornillos
que indica las fotos de abajo (ventilador simple o doble)
.
Reinstale
la o las
rueda(s) del ventilador en su posición y la tapa.
HD0080
HD0081
21
HD0023
DELANTE
HD0023
1
2
- 43 -
12. LUCES HALÓGENAS
Esta campana utiliza bombillas halógenas de 50W (120V, 50W, PAR 20).
Instale la bombilla girando en el sentido de las agujas del reloj.
13. LAMPÁRA TERMÓGENA
Las bombillas termógenas necesarias son bombillas infrarrojas de 175W max. (120V, IR175W, PAR 38).
Usted puede utilizar las bombillas halógenas blancas, si las tablas termogénas no son utilizadas (120V, IR175W, PAR 38).
Instale la bombilla girando en el sentido de las agujas del reloj.
14. INSTALE LOS FILTROS
Es recomendable de instalar los filtros de lado en primer lugar y de terminar con el o los filtro del centro.
INSTALACI
ÓN DE LOS FILTROS
1. Deslice la parte superior de los filtros en la campana.
2. Giro la parte inferior hacia el interior de la campana.
3. Instale los filtros debajo del atadero y tire.
4. Cuando este tirando sobre los filtros, deslice debajo de la pieza del retenido interior.
Los filtros de zig zag son disponibles en opción (ver la hoja de instalación que se encuerta incluida con los filtros a zig zag).
1) Atadero
15. MANTENIMIENTO
Filtros y la(s) rueda(s) del ventilador.
Los filtros, canal y la(s) rueda(s) del ventilador deben ser frecuentemente limpiadas. Use agua tibia y una solución de
detergente. Los filtros y la(s) rueda(s) del ventilador se pueden lavar en el lavaplatos.
HD0009
HD0010
1
- 44 -
15. MANTENIMIENTO (CONTINUACIÓN)
L
impieza de la campana
Acero inoxidable: como mantener una apariencia brillante.
Lo que debe hacer:
- Lavar regularmente la superficie con un trapo o un paño empapado de agua tibia y de jabón suave o detergente a
vajilla.
- Siempre limpie en el sentido de las líneas originales de pulimento.
- Siempre enjuague bien con agua limpia (2 a 3 veces) después de haber limpiado seque completamente la superficie.
- Usted puede utilizar un limpiador doméstico hecho especialmente para el acero inoxidable.
Lo que no debe hacer:
- No utilice ninguna lana de acero o de acero inoxidable o todo otro raspador para quitar la suciedad tenaz.
- No utilice ningún limpiador en polvo abrasivo o riguroso.
- No deje la suciedad acumularse.
- No deje el polvo de yeso o todo otro residuo de construcción que caiga en la campana, cúbrala durante el trabajo
para asegurarse que en ningún caso el polvo se pegue a la superficie del acero.
A evitar cuando elige un detergente:
- Todos los productos de limpieza que contienen agentes de blanqueo; van a deteriorar el acero inoxidable.
- Todos los productos que contienen cloruro, fluoruro, yoduro o bromuro; estos deterioran rápidamente las superficies.
- Todos los productos combustible utilizados para la limpieza: acetona, alcohol, éter, benzol, etc...; son extremamente
explosivos y no deben ser utilizados cerca de una cocina.
Superficies pintadas:
Limpie con agua caliente agregue solamente un detergente suave. Si hay decoloración, utilice una buena cera a pintura
como una cera para auto. (NO UTILICE un limpiador casero rugoroso o un limpiador a porcelana.)
16. FUNCIONAMIENTO
Siempre hacer funcionar la campana antes de comenzar a cocinar a fin de establecer una circulación de aire en la
cocina. Deje igualmente funcionar la campana algunos minutos después de que pare de cocinar a fin de limpiar el aire.
Esto ayuda a concervar la cocina mas limpia y un aire puro.
1
1
2
3
4
1) Lámparas termogénas
2) Luces halógenas
3) Encender/apagar ventilador
4) Control de velocidad del ventilador
HD0013
VENTILADOR
El ventilador funciona con la ayuda de dos controles.
Utilice el interruptor encender/apagar tiene una luz roja para encender y apagar el ventilador. Cuando está en tensión,
el ventilador funciona a la velocidad utilizada la última vez.
Utilice el control de velocidad del ventilador girando en el sentido de las agujas del reloj para disminuir la velocidad y
en el sentido contrario de las agujas del reloj para aumentar la velocidad.
LÁMPARAS HALÓGENAS
Los dos interruptores de encender/apagar controlan las luces halógenas.
El interruptor a báscula antes, controla la luz del centro (para las campanas 42’ y 48’’). El interruptor detrás controla
las luces de cada lado. (Cada interruptor controla la luz para las campanas de 30’ y 36’’.)
Encienda una o dos luces según su necesidad. Utilice las bombillas de halógenas PAR 20, 50W.
- 45 -
LÁMPARAS TERMOGÉNA (INFRARROJAS)
Cada lámpara es controlada independientemente con su propio interruptor. Utilice las bombillas infrarrojas (120V,
IR175W, PAR38) o las bombillas halógenas (120V, 90W, PAR38) si las tablas sirven para recalentar los alimentos no
son utilizadas.
HEAT SENTRY
Su campana esta equipada con Heat Sentry. Este termostato tiene un mecanismo que se encenderá o acelerará el
ventilador si se detecta un calor excesivo encima de la cocina.
1.-Si el ventilador esta apagado - el se prenderá a una velocidad máxima.
2.-Si el ventilador esta encendido a una velocidad mínima - el se prenderá a una velocidad máxima.
Cuando la temperatura disminuye a un nivel normal, el ventilador vuelve a la función de origen.
ADVERTENCIA
HEAT SENTRY puede comenzar a funcionar al igual si la campana esta parada. En este caso, es
imposible parar el ventilador con los interruptores. Si usted para la campana, halago a partir del
panel eléctrico principal.
!
ADVERTENCIA
Jamás dejar materias inflamables debajo de las lámparas termogéna.
!
16. FUNCIONAMIENTO (CONTINUACIÓN)
GARANTÍA
BROAN-NUTONE LLC GARANTÍA LIMITADA POR UN AÑO
Broan-NuTone LLC garantiza al consumidor comprador original de sus productos que dichos productos carecerán
de defectos en materiales o en mano de obra por un período de un año a partir de la fecha original de compra.
NO EXISTEN OTRAS GARANTÍAS, EXPRESAS O IMPLÍCITAS, INCLUYENDO, PERO NO LIMITADAS A,
GARANTÍAS IMPLÍCITAS DE COMERCIALIZACIÓN O ACTITUD PARA UN PROPOSITO PARTICULAR.
Durante el período de un año, y a su propio criterio, Broan-NuTone LLC reparará o reemplazará, sin costo todo
producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso.
Esta garantía no cubre (a) mantenimiento y servicios normales o (b) cualquier productos o piezas que hayan sido
mantenidas o reparadas en inapropiadamente (por otras compañías que sea Broan-NuTone LLC), instalación
defectuosa, o instalación no conforme a las instrucciones de instalación recomendadas.
La duración de cualquier garantía implícita se limita a un periodo de un año como se especifica en la garantía
expresa. Algunos estados o provincias no permiten limitaciones en cuanto al tiempo de expiración de una garantía
implícita, por lo que la limitación antes mencionada puede no aplicarse a usted.
LA OBLIGACIÓN DE BROAN-NUTONE LLC DE REPARAR O REEMPLAZAR, SIGUIENDO EL CRITERIO DE
BROAN-NUTONE LLC DEBERÁ SER EL UNICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO
ESTA GARANTÍA. BROAN-NUTONE LLC NO SERÁ RESPONSABLE POR DAÑOS ACCIDENTALES,
CONSIGUIENTES, O POR DAÑOS ESPÉCIALES SURGIDOS O EN CONEXIÓN CON EL USO O EL
RENDIMIENTO DEL PRODUCTO. Algunos estados o provincias no permiten la exclusión o limitación de daños
accidentales o consiguientes, por lo que la limitación antes mencionada puede no aplicarse a usted. Esta garantía
le proporciona derechos legales específicos, y usted puede también tener otros derechos, los cuales varían de
estado a estado o de provincia a provincia. Esta garantía reemplaza todas las garantías anteriores. Para calificar en
el servicio de garantía, usted debe (a) notificar a Broan-NuTone LLC al uno domicilio o telephono que menciona
abajo, (b) dar el número del modelo y la identificación de la pieza y (c) describir la naturaleza de cualquier defecto
en el producto o pieza. En el momento de solicitar servicio cubierto por la garantía, usted debe presentar
evidencia de la fecha original de la compra.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)
- 46 -
28 910112
8
17
17
17
5
6
14
12
13
7
15
16
4
3
20
19
17
2
2
17
18
1
HL0002
REPUESTOS
Serie 64000
REF. N.° CTD (largo de la campana)
N.° PIEZA
DESCRIPCIÓN
30” 36” 42” 48”
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
V06750
V02264
V02773
V02772
V03435
V03436
V03501
V03507
V03502
V03503
V03504
V03505
V03517
V03518
V03519
V03520
V00673
V02512
V01869
V01582
V00606
V03509
V03510
V13216
V13217
V13218
V13219
V03686
V02544
V03598
V03515
V13278
LOGOTIPO BROAN ELITE
CASQUETE
CONNECTADOR MACHO
CONNECTADOR HEMBRA
TERMOSTATO
SOPORTE POR TERMOSTATO
CONTROL DE VELOCIDAD
INTERRUPTOR SIMPLE SPST PARA LAMPARA TERMÓGENA
INTERRUPTOR DOBLE SPST PARA LAMPARA HALÓGENA
INTERRUPTOR SIMPLE ILLUMINADO SPST POR VENTILADOR
BOTÓN CONTROL DE VELOCIDAD
TERMINAL DE CONEXIÓN
CABLE DE ALIMENTACIÓN 10"
CABLE LÁMPÁRA TERMOGÉNA 10"
CABLE CONTROL 10"
CABLE INTERRUPTOR ILUMINADO 10"
TUERCA DENTELLADA N.° 8-32
TORNILLO N.° 8-32 x 1/2"
TORNILLO MECÁNICO N.° 6-32 x 1/4"
TUERCA DENTELLADA N.° 6-32
TORNILLO N.° 8-3/8" T/B CABEZA N.° 8
FILTRO RANGEMASTER 8,930
x 9,800
FILTRO RANGEMASTER 11,930
x 9,800
CANAL 30"
CANAL 36"
CANAL 42"
CANAL 48"
GRAPA FILTROS
BOMBILLA HALOGENA PAR 20 50 W
LAMPARA TERMOGÉNA
MANUAL DE INSTALACIÓN
BOLSA DE INSTALACIÓN ((4) tuercas a brida N.° 10-32, (1) alambre eléctrico LP16-AP,
(2) conectador de cable N.° 74B, (8) tornillo doble hillilo 6-12 x 0.5, (6) tornillo N.° 8 x 3/8”,
(2) tornillo N.° 6 x 1/2")
1
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
2
1
1
-
-
-
3
2
2
1
1
1
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
-
3
-
1
-
-
3
2
2
1
1
1
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
2
2
-
-
1
-
4
3
2
1
1
1
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
-
4
-
-
-
1
4
3
2
1
1
- 47 -
REPUESTOS
REF. N.°
N.° PIEZA
DESCRIPCIÓN CTD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
V13296
V03500
V12997
V03577
V02160
V01869
V01857
V01582
V14973
V01810
V03400
V01766
V00871
V02001
V01831
V11705
V11614
V01927
V03495
V03494
V13230
V03496
V00660
V05520
V00613
1
1
1
1
1
4
1
1
1
2
1
1
3
3
2
1
1
4
1
1
1
1
1
2
2
ADAPTADOR & COMPUERTA 3
1
/4 x 10’
DEFLECTOR DE AIRE
MONTAJE DE PLACA DE VENTILADOR SIMPLE
ESPUMA 1/2” x 1/2” x 12”
CONDENSADOR 15MFD
TORNILLO MECÁNICO N.° 6-32 x 1/4”
CUBRE-CABLE
TUERCA DENTELLADA N.°6-32
MONTAJE DE VENTILADOR SIMPLE
ANILLO RUEDA
RUEDA CAMPANA 7,094” x 3,375” CW
MOTOR 165W CW
ARANDELA 3/16” DI x 3/4’ DE
OJETE MOTOR G-431-1
ABRAZADERA 8”
SOPORTE MOTOR
CABLE N.°18 TEW MARRÓN x 10”
TORNILLO METRICO M4 x 6
MM (TIPO PAN) QDRX
APAGO DE TRACCIÓN CABLE VENTILADOR
CABLE ALIMENTACIÓN VENTILADOR 36”
PUERTA CONEXIÓN ELÉCTRICA
CABLE ALIMENTACIÓN 120 VOLTIOS
APAGO DE TRACCIÓN CABLE ALIMENTACIÓN
TORNILLO N.°8 x 3/8”, T/B, CABEZA N.° 8
TORNILLO N.° 10-32 x 3/8”, TF, VERDE
PLACA Y VENTILADOR SIMPLE
(Modelo P5)
HL0021
19
21
18
17
20
22
2
3
23
4
1
9
6
8
5
15
14
13
6
16
12
7
11
10
REPUESTOS
REF. N.°
N.° PIEZA
DESCRIPCIÓN CTD.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
V14971
V13296
V03500
V14975
V03577
V01582
V02160
V01857
V01766
V03400
V14974
V01810
V03399
V03457
V00871
V01831
V11705
V11614
V02001
V01927
V03495
V03494
V14960
V00660
V03496
V00606
V00613
1
1
1
1
1
1
2
2
1
1
1
2
1
1
6
4
2
2
6
8
1
1
1
1
1
4
2
ADAPTADOR & COMPUERTA 3
1
/4 x 14’
ADAPTADOR & COMPUERTA 3
1
/4 x 10’
DEFLECTOR DE AIRE
MONTAJE DE PLACA DE VENTILADOR DOBLE
ESPUMA 1/2” x 1/2” x 12”
TUERCA DENTELLADA N.
O
6-32
CONDENSADOR 15MFD
CUBRE-CABLE
MOTOR 165W CW
RUEDA CAMPANA 7,094” x 3,375” CW
MONTAJE DE VENTILADOR DOBLE
ANILLO RUEDA
RUEDA CAMPANA 7,094” x 3,375” CCW
MOTOR 165W CCW
ARANDELA 3/16” DI x 3/4” DE
ABRAZADERA 8”
SOPORTE MOTOR
CABLE N.°18 TEW MARRÓN x 10”
OJETE MOTOR G-431-1
TORNILLO MÉTRICO M4 X 6
MM (TIPO PAN) QDRX
APAGO DE TRACCIÓN CABLE VENTILADOR
CABLE ALIMENTACIÓN VENTILADOR 36”
PUERTA CONEXIÓN ELÉCTRICA
APAGO DE TRACCIÓN CABLE ALIMENTACIÓN
CABLE ALIMENTACIÓN 120 VOLTIOS
TORNILLO N.°8 x 3/8”, T/B, CABEZA N.°8
TORNILLO N.° 10-32 x 3/8”, TF, VERDE
21
22
23
2
3
20
24
25
1
19
18
17
16
15
13
6
9
10
11
12
14
4
5
7
8
PLACA Y VENTILADOR DOBLE
(Modelo P8)

Transcripción de documentos

INSTALLATION INSTRUCTIONS HB0056 64000 SERIES ! INTENDED FOR DOMESTIC COOKING ONLY ! READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 11 TO 13 Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626) REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register V03515 rev. J ! WARNING ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 1. 2. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Do not use this unit with any additional solid-state speed control device. 8. To reduce the risk of fire, use only steel ductwork. 9. This unit must be grounded. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN – You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels – This could cause a violent steam explosion. 4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and you know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA. CAUTION 1. 2. 3. 4. TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 5. a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. 6. b) Always turn hood ON when cooking at high heat or when cooking flaming foods. c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. d) Use proper pan size. Always use cookware appropriate for the size of the surface element. 7. 8. 9. 10. 11. -2- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it will be cooled down. If the motor continues to shut off and restart, have the hood serviced. For best capture of cooking impurities, the bottom of the hood should be at a minimum of 20’’ (24” over a gas range) and at a maximum of 30” above the cooking surface. Two installers are recommended because of the large size and weight of this hood. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside – Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel. Because of the high exhausting capacity of this hood, you should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen. To reduce the risk of fire and electric shock, the Broan Elite 64000 Series hood must be installed with Broan interior blower models P5 or P8; Broan exterior blower models 331H, 332H, 335 or 336; Broan in-line blowers models HLB3, HLB6, HLB9, HLB11. Other blowers cannot be substituted. (Blowers sold separately.) Use with approved cord-connection kit only. Please read specification label on product for further information and requirements. - 64000 SERIES RANGE HOOD SYSTEM INTERIOR BLOWERS Model 634 or 644 (roof cap) Model 647 (7” Rd wall cap) Model 643 (8” Rd wall cap) Model 418 10” round adjustable elbow (optional) Model 415 7” round adjustable elbow (optional) 8” round standard duct Model 407 (7” round 2 ft. sections) Model 412 transition (31/4” x 10” to 7”) Standard duct (31/4” x 10”) Model 413 transition (31/4” x 10” to 8”) Model 459 transition (31/4” x 14” to 8”) Duct (31/4” x 14”) Adapter and damper 31/4” x 10” (supplied with P5 and P8 blowers) Adapter and damper 31/4’’ x 14’’ (supplied with P8 blower) Flow deviator (vertical exhaust only) (supplied with P5 and P8 blowers) 64000 SERIES HOOD Model P8 dual-blower (900 cfm) for use with 36’’ hoods or wider Rough-in kit (supplied with P5 and P8 blowers) Model P5 single-blower (500 cfm) NOTE: The dual blower P8 can be installed either with 31/4’’ x 14’’ or 31/4’’ x 10’’ ducts. For optimal air and quiet sound performance, use 31/4’’ x 14’’ ducts. RMP Series Backsplash (Stainless Steel wall covering with warming shelves. Optional) HL0070 -3- - 64000 SERIES RANGE HOOD SYSTEM IN-LINE AND EXTERIOR BLOWERS Model 437 (High capacity roof cap) Model 441 Model HLB9 (800 cfm) (10” Rd wall cap) Model 335 (1200 cfm) or HLB11 (1100 cfm) or 336 (1500 cfm) in-line blower Model 331H (600 cfm) exterior blower (includes two 8” x 12” to or 332H (900 cfm) 10’’ round transitions) exterior blower Model 441 (10” Rd wall cap) Model HLB6 (600 cfm) in-line blower (includes two 4½” x 18½” to 10’’ round transitions) Model HLB3 (280 cfm) in-line blower (includes one 8” to 10” round transition) Model 421 (10” Rd. vert. in-line damper) Recommended for use with exterior blowers Model 418 10” Rd adjustable elbow (optional) Model 410 (10” Rd duct 2ft. sections) 64000 SERIES HOOD 332KR in-line and exterior blower rough-in kit - Purchase separately. RMP Series Backsplash (Stainless Steel wall covering with warming shelves. Optional) HL0071 -4- 1. SELECT BLOWER OPTION AND INSTALL DUCTWORK Either an interior or exterior blower or in-line blower may be used with this hood. The Broan Elite 64000 Series must be installed with blower models P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers cannot be substituted. (Blowers sold separately). Plan where and how the ductwork will be installed. If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 3, 6, 9, 10, 12 and up of this manual. Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7” or 8” round ducts, or 31/4’’ x 14’’ duct, use a transition. Use 2” duct tape to seal duct joints. The minimum hood distance above cooktop must not be less than 20’’ for an electric range and 24’’ for a gas range. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities. Distances over 30” are at the installer and users discretion. Roof cap Roof cap 3¼” x 14” to 8” transition if 3¼” x 14” duct Wall cap Wall cap 3¼” x 10” or 3¼” x 14” duct 7” or 8” round duct 3¼” x 10” to 7” or 8” transition Hood with interior blower Hood 20” minimum above cooking surface (24” for gas) HH0029A HH0015A MODEL P5 (SINGLE) OR P8 (DOUBLE) INTERIOR BLOWER TYPICAL RECTANGULAR DUCTWORK 20” minimum above cooking surface (24” for gas) MODEL P5 (SINGLE) OR P8 (DOUBLE) INTERIOR BLOWER 7’’ OR 8’’ ROUND DUCTWORK Exterior blower Roof cap 10” round duct In-line blower Exterior blower 10” round duct Wall cap Hood HH0016A 20” minimum above cooking surface (24” for gas) HH0060A MODEL 331H, 332H, 335 OR 336 EXTERIOR BLOWER TYPICAL DUCTWORK Hood 20” minimum above cooking surface (24” for gas) MODEL HLB3, HLB6, HLB9 OR HLB11 IN-LINE BLOWER TYPICAL DUCTWORK -5- 2. PREPARE THE INSTALLATION Make sure that the following items are included: - Range hood - Accessories: • Filters • Bag of parts including: (4) lock nuts, (1) wire clamp, (8) 1/2” double thread screws, (2) wire connectors, (2) 1/2” standard screws, (6) 3/8” screws. Parts sold separately: - Interior blower Model P5 includes blower, rough-in kit, flow deviator and 31/4” x 10” adapter Interior blower Model P8 includes blower, rough-in kit, flow deviator and 31/4” x 10” adapter and 31/4” x 14” adapter In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition) In-line and exterior blower rough-in plate model 332KR, required for all In-line or Exterior Blowers Exterior blower assembly 331H, 332H, 335 or 336 Halogen lights (120V, 50W, PAR 20) Heat lamps (120V, IR 175W, PAR 38) RMP Series Backsplash (optional) Baffle filters (optional) Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model numbers. NOTE: For cabinets with recessed bottom, attach wood filler strips (not included) on each sides, as shown below. Use two (2) 2-inch wide strips for 30’’ wide hoods, and four (4) 2-inch wide strips for wider hoods, cut to length. See below for wood filler strip locations. HOOD WIDTHS 30’’ 36’’ 42’’ 48’’ A 2’’ 2’’ 2’’ 4’’ LOCATIONS B C N/A N/A 41/2’’ 41/2’’ 1 7 /4’’ 81/4’’ 1 111/4’’ 10 /4’’ A HD0079 A B C 3. INSTALL BACKSPLASH (OPTIONAL) Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel or cooktop. (See instructions packed with backsplash.) 4. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR) INTERIOR BLOWER: Follow all subsequent steps of this manual. EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 6, 10, 12 and up of the present manual. -6- 5. CHOOSE THE OPENING (INTERIOR BLOWER) Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate). See pictures below. CAUTION When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the knockout corresponding to the ducting installed (10’’ or 14’’). UT CKO NO 14’’ K 14’’ KNOCKOUT 10’’ KNOCKOUT OUT OCK KN 10’’ HD0076 HD0077 Removing horizontal knockout opening on back of hood Removing vertical knockout opening on rough-in plate 6. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS) INTERIOR BLOWER: Secure the rough-in plate (provided with the P5 and P8 blower) inside the hood with four (4) lock nuts. See picture below. HD0042 EXTERIOR OR IN-LINE BLOWER: Purchase Model 332KR separately. Refer to instructions included with the rough-in kit. Secure the rough-in plate inside the hood with (4) lock nuts. 7. INSTALL THE DEVIATOR (INTERIOR BLOWER) YOU MUST install the deviator if you choose to vent the hood vertically. Install the deviator as shown. NOTE: If installed correctly, the deviator will protrude about 1/8” above the rough-in plate. HD0003 -7- Inserting deviator into hood vertical opening 8. INSTALL THE ADAPTER (INTERIOR BLOWER) Using two (2) standard 1/2’’ screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood using duct tape. HD0005 HD0006 9. INSTALL THE HOOD (ALL BLOWERS) INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover, place the wire clamp, insert the cable in the hood and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the adapter/damper assembly enters the ducting. Secure the hood by tightening the screws completely. HD0043 EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover on top of the hood and connect wiring (see instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure the hood by tightening the screws completely. -8- 10. CONNECT WIRING (ALL BLOWERS) ! WARNING Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally. INTERIOR BLOWER: Connect cable into wiring box using wire connectors. Connect wires as follow: BLACK to BLACK, WHITE to WHITE and GREEN or BARE wire under ground screw. Reinstall wiring cover. DO NOT FORGET TO CONNECT THE GROUND. HD0007 1 1) Ground screw IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included witn in-line or exterior blower). 11. INSTALL THE BLOWER (INTERIOR BLOWER) The blower must be installed to the rough-in plate using (4) 3/8” screws for the single blower unit and (6) 3/8” screws for the dual blower unit. Remove the cover from the blower assembly. Remove the impeller(s) by pulling them out gently (see pictures below). HD0022 HD0021 -9- 11. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D) Install screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten screws down fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower to its position (screws in the small part of the keyhole). Tighten the screws. HD0044 HD0044 Dual blower (P8) Single blower (P5) Secure the blower by installing 2 more screws into the locations shown in the pictures below (single blower or dual blower). Reinstall impeller(s) and cover. HD0080 HD0081 Single blower (P5) Dual blower (P8) FRONT HD0023 2 FOR DUAL BLOWER UNIT, MAKE SURE THE IMPELLERS ARE CORRECTLY INSTALLED, THE HOOD WILL NOT WORK PROPERLY IF REVERSED. Both impellers are different in the dual blower, one rotates clockwise and the other counterclockwise. Each wheel and motor have an arrow and a number on them, you have to match them correctly (see drawing beside). 1 1 2 HD0023 ! WARNING Never plug the 2-prong blower cord to the 3-prong power supply cord. Plug the power supply to the 3-prong male connector (A) and the blower unit into the 2-prong female receptacle (B) inside the hood. A HE0003 - 10 - B 12. LIGHT BULBS This range hood uses 50W halogen lamps. (120V, 50W, PAR 20) Install the lamps by rotating them clockwise into their socket holder. 13. HEAT LAMPS The heat lamps required are 120V, 175W max, infrared bulbs. (120V, IR 175W, PAR 38) White halogen lights can be used if warming shelves are not used. (120V, 90W, PAR 38) Install the lamps by rotating them clockwise into their socket holder. 14. INSTALL FILTERS It is recommended to install side filters first and finish with center one(s). 1. 2. 3. 4. Insert upper end of filter into the hood (tab end). Raise lower end toward the inside of hood. Position lower end of filter into channel and pull on filter tab. While pulling the filter tab, slide the filter top under the inner retaining piece. Baffle filters are available as an option (see instruction sheet included with baffle filters). HD0009 HD0010 1 1) Tabs 15. USE AND CARE Grease filters and impeller(s). The grease filters, impeller(s) and grease rail should be cleaned frequently. Use a warm detergent solution. Grease filters and impeller are dishwasher safe. Remove filters by pushing filters towards the back of hood and rotating filters downward. - 11 - 15. USE AND CARE (CONT’D) Hood cleaning Stainless steel cleaning: How to maintain its « BRIGHT LOOK » Do: - Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent. - Always clean in the direction of original polish lines. - Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely. - You may also use a specialized household stainless steel cleaner. Don’t: - Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt. - Do not use any harsh or abrasive cleansers. - Do not allow dirt to accumulate. - Do not let plaster dust or any other construction residues reach the hood. During construction or renovation, cover the hood to make sure no dust sticks to stainless steel surface. Avoid: when choosing a detergent - Any cleaners that contain bleach will attack stainless steel. - Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly. - Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be used close to a range. Enamel finish: Clean with warm water and mild detergent only. When discoloration occurs, use a good enamel polish such as automotive polish. (DO NOT use rough abrasive cleaner or porcelain cleaner.) 16. OPERATION Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter. 1 1 HC0028 2 3 4 1) Warming lamp switches 2) Halogen light switches 3) ON/OFF blower switch 4) Blower speed control BLOWER The blower is operated using two (2) controls. Use the red, lighted on/off switch to start and stop the blower. When turned on, the blower will operate at the previous setting of the speed control. Turn the speed control knob clockwise to decrease blower speed – counterclockwise to increase speed. COOKTOP LIGHTING (HALOGEN) A double set of ON/OFF switches controls the halogen lights. The front rocker controls the center light (for 42” and 48” hoods). The rear rocker controls both side lights (each switch controls one light for 30” and 36” hood). Select one, two or three lights for best cooking lighting. Use PAR 20, 50W halogen bulbs. - 12 - 16. OPERATION (CONT’D) ! WARNING Never place highly flammable material under warming lamps. WARMING LAMPS (INFRARED) Each warming lamp is controlled with its own ON/OFF switch. Use infrared light bulbs (120V, IR175W, PAR38) or white halogen bulbs (120V, 90W, PAR38) if food warming shelves are not used. HEAT SENTRY This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface. 1) If blower is OFF - it turns blower ON to HIGH speed. 2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed. ! WARNING The HEAT SENTRY can start the blower even if the hood is turned OFF. In this case, it is impossible to turn the blower OFF with blower switch. If you must stop the blower, do it from the main electrical panel. When the temperature level drops to normal, the blower will return to its original setting. WARRANTY BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone LLC), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to another. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone LLC at one of the addresses or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626) - 13 - SERVICE PARTS 64000 Series 1 2 18 2 20 17 17 19 3 7 12 6 5 13 4 15 16 14 17 17 17 8 2 9 10 11 2 8 HL0002 KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 PART NUMBER V06750 V02264 V02773 V02772 V03435 V03436 V03501 V03507 V03502 V03503 V03504 V03505 V03517 V03518 V03519 V03520 V00673 V02512 V01869 V01582 V00606 V03509 V03510 V13216 V13217 V13218 V13219 V03686 V02544 V03598 V03515 V13278 DESCRIPTION BROAN ELITE LOGO SOCKET LAMP MALE CONNECTOR FEMALE CONNECTOR THERMOSTAT THERMOSTAT BRACKET SPEED CONTROLLER SPST SINGLE SWITCH FOR WARMING LAMP SPST DOUBLE SWITCH FOR HALOGEN LIGHT SPST LIGHTED SINGLE SWITCH FOR BLOWER SPEED CONTROL BUTTON TERMINAL STRIP 10" POWER CORDS 10" CORDS FOR HEAT LAMP 10" CONTROL WIRE 10" LIGHTED SWITCH WIRE LOCK NUT NO. 8-32 SCREW NO. 8-32 x 1/2" QUADREX MACHINE SCREW NO. 6-32 x 1/4" LOCK NUT NO. 6-32 SCREW NO. 8-3/8"T/B NO. 8 HEAD RANGEMASTER FILTER 8.930” x 9.800” RANGEMASTER FILTER 11.930” x 9.800” GREASE RAIL 30" GREASE RAIL 36" GREASE RAIL 42" GREASE RAIL 48" FILTER CLIP HALOGEN LAMP PAR 20 50 W HEAT LAMP INSTALLATION GUIDE PARTS BAG ((4) lock nut no.10-32, (1) wire clamp LP16-AP, (2) wire connectors no.74B, (8) double thread screw 6-12 x 0.5, (6) no. 8 x 3/8” screws, (2) no. 6 x 1/2" screws) - 14 - QTY (hood width) 30” 36” 42” 48” 1 1 1 1 4 4 5 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 7 7 8 8 2 2 1 3 2 4 1 1 1 1 3 3 4 4 2 2 3 3 2 2 2 2 1 1 1 1 1 1 1 1 SERVICE PARTS SINGLE BLOWER/ROUGH-IN (Model P5) 1 20 21 2 23 22 19 3 4 17 5 6 8 7 18 16 15 14 13 6 12 9 11 10 HL0021 KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NUMBER V13296 V03500 V12997 V03577 V02160 V01869 V01857 V01582 V14973 V01810 V03400 V01766 V00871 V02001 V01831 V11705 V11614 V01927 V03495 V03494 V13230 V03496 V00660 V05520 V00613 DESCRIPTION ADAPTER AND DAMPER 31/4’’ x 10’’ AIR DEFLECTOR SINGLE BLOWER ROUGH-IN PLATE ASSEMBLY FOAM 1/2” x 1/2” x 12” CAPACITOR 15MFD MACHINE SCREW NO. 6-32 x 1/4” WIRE COVER LOCK NUT NO. 6-32 SINGLE BLOWER ASSEMBLY IMPELLER RING BLOWER IMPELLER 7.094” x 3.375” CW MOTOR 165W CW WASHER 3/16” ID x 3/4’’ OD MOTOR GROMMET G-431-1 8” TIE WRAP MOTOR MOUNT WIRE NO. 18 TEW BROWN x 10” METRIC SCREW M4 x 6MM PAN QDRX STRAIN RELIEF FOR BLOWER POWER CORD 36” BLOWER POWER CORD OUTLET BOX COVER POWER CORD, 120 VOLTS STRAIN RELIEF FOR POWER CORD SCREW NO. 8 x 3/8”, T/B, NO. 8 HEAD SCREW NO. 10-32 x 3/8, TF, GREEN - 15 - QTY 1 1 1 1 1 4 1 1 1 1 1 1 3 3 2 1 1 4 1 1 1 1 1 2 2 SERVICE PARTS DUAL BLOWER/ROUGH-IN (Model P8) 2 1 25 3 4 24 23 22 21 5 19 18 17 16 15 14 6 7 8 11 20 9 13 10 12 KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PART NUMBER V14971 V13296 V03500 V14975 V03577 V01582 V02160 V01857 V01766 V03400 V14974 V01810 V03399 V03457 V00871 V01831 V11705 V11614 V02001 V01927 V03495 V03494 V14960 V00660 V03496 V05520 V00613 DESCRIPTION ADAPTER AND DAMPER 3 /4” x 14’’ ADAPTER AND DAMPER 31/4” x 10’’ AIR DEFLECTOR DUAL BLOWER ROUGH-IN PLATE ASSEMBLY FOAM 1/2” x 1/2” x 12” LOCK NUT NO. 6-32 CAPACITOR 15MFD WIRE COVER MOTOR 165W CW BLOWER IMPELLER, HOOD 7.094” x 3.375” CW DUAL BLOWER ASSEMBLY IMPELLER RING BLOWER IMPELLER, HOOD 7.094” x 3.375” CCW MOTOR 165W CCW WASHER 3/16” ID x 3/4 OD 8” TIE WRAP MOTOR MOUNT WIRE NO.18 TEW BROWN x 10” MOTOR GROMMET G-431-1 METRIC SCREW M4 x 6MM PAN QDRX STRAIN RELIEF FOR BLOWER POWER CORD 36” BLOWER POWER CORD OUTLET BOX COVER STRAIN RELIEF FOR POWER CORD POWER CORD, 120 VOLTS SCREW NO. 8 x 3/8”, T/B, NO. 8 HEAD SCREW NO. 10-32 x 3/8”, TF, GREEN 1 - 16 - QTY 1 1 1 1 1 1 2 2 1 1 1 2 1 1 6 4 2 2 6 8 1 1 1 1 1 4 2 GUIDE D’INSTALLATION HB0056 SÉRIE 64000 ! CONÇUE UNIQUEMENT POUR LA CUISSON DOMESTIQUE ! LIRE ET CONSERVER CES INSTRUCTIONS INSTALLATEUR : LAISSER CE MANUEL AU PROPRIÉTAIRE PROPRIÉTAIRE : INSTRUCTIONS D’UTILISATION ET D’ENTRETIEN EN PAGES 27 À 29 Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626) ENREGISTREZ VOTRE PRODUIT EN LIGNE À : www.broan.com/register V03515 rév.J ! AVERTISSEMENT ! AVERTISSEMENT AFIN DE RÉDUIRE LES RISQUES D’INCENDIE, D’ÉLECTROCUTION OU DE BLESSURES CORPORELLES, SUIVEZ LES INSTRUCTIONS SUIVANTES : AFIN D’ÉVITER TOUT RISQUE DE BLESSURES DANS LE CAS D’UN FEU DE CUISINIÈRE, SUIVEZ CES DIRECTIVES* : 1. N’utilisez cet appareil que de la façon prévue par le manufacturier. Si vous avez des questions, contactez le manufacturier à l’adresse et au numéro de téléphone indiqués sur la garantie. 1. 2. Avant de réparer ou de nettoyer l’appareil, coupez l’alimentation électrique en verrouillant le panneau de service afin d’éviter sa remise en marche accidentelle. Si le panneau de service ne peut être verrouillé, y fixer un avertissement en évidence. 3. Les travaux d’installation et de raccordement électrique doivent être effectués par une personne qualifiée, conformément aux codes et standards de construction, incluant ceux concernant le feu. 4. Une quantité d’air adéquate est requise afin d’assurer une bonne combustion et l’évacuation des gaz par la cheminée dans le cas des équipements alimentés au gaz, afin de prévenir les retours de cheminée. Conformez-vous aux instructions et aux standards de sécurité des manufacturiers d’équipement de chauffage, tel que publiés par la National Fire Protection Association (NFPA), et l’American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), ainsi que les responsables des codes locaux. 5. Lorsque vous coupez ou perforez un mur ou un plafond, prenez garde de ne pas endommager les fils électriques ou tout appareil cachés. 6. Les ventilateurs avec conduits doivent toujours évacuer l’air à l’extérieur. 7. Ne pas utiliser cet appareil avec une commande de vitesse à semiconducteur additionnelle. 8. Afin de réduire les risques d’incendie, n’utilisez que des conduits de métal. 9. Cet appareil doit être mis à la terre. AFIN DE RÉDUIRE DE CUISINIÈRE : LES RISQUES Étouffez les flammes avec un couvercle hermétique, une tôle à biscuits ou un plateau métallique et ensuite, éteindre le brûleur. PRENEZ SOIN D’ÉVITER LES BRÛLURES. SI LES FLAMMES NE S’ÉTEIGNENT PAS IMMÉDIATEMENT, ÉVACUEZ LES LIEUX ET APPELEZ LES POMPIERS. 2. NE PRENEZ JAMAIS UNE CASSEROLE EN FLAMMES DANS VOS MAINS – Vous pourriez subir des brûlures. 3. N’UTILISEZ PAS D’EAU, incluant linge à vaisselle ou serviette mouillés – ceci pourrait occasionner une violente explosion. 4. N’utilisez un extincteur QUE DANS LE CAS OÙ: A. Vous savez qu’il s’agit d’un extincteur de classe ABC et que vous en connaissez le fonctionnement. B. L’incendie est petit et limité à l’endroit où il a débuté. C. Les pompiers ont été avisés. D. Vous pouvez combattre l’incendie en ayant accès à une sortie de secours. *Tirées du Kitchen Fire Safety Tips publié par la NFPA. ATTENTION 1. 2. 3. 4. DE FEU 5. a) Ne jamais laisser les appareils de cuisson sans surveillance lorsqu’ils sont réglés à feu vif. Les débordements engendrent de la fumée et des déversements graisseux pouvant s’enflammer. Chauffez l’huile lentement, à feu doux ou moyen. b) Toujours mettre la hotte en marche lorsque vous cuisinez à feu vif ou que vous cuisinez des mets flambés. c) Nettoyez régulièrement la (les) roue(s) du ventilateur. Ne laissez pas la graisse s’accumuler sur le ventilateur ou les filtres. 8. Utilisez le bon format de casserole. Servez-vous toujours de casseroles et d’ustensiles appropriés à la dimension de la surface chauffante. 9. d) 6. 7. 10. 11. - 18 - Pour usage domestique seulement. Ne pas utiliser pour évacuer des vapeurs ou des produits dangereux ou explosifs. Afin d’éviter tout dommage au moteur et de débalancer ou de rendre bruyante la roue du moteur, garder votre appareil à l’abri des poussières de placoplâtre et de construction/rénovation, etc. Le moteur de votre hotte possède une protection thermique qui éteindra automatiquement le moteur s’il devient surchauffé. Le moteur repartira automatiquement une fois refroidi. Si le moteur continue à arrêter et à repartir, faites-le vérifier. Pour une meilleure évacuation des odeurs de cuisine,le bas de votre hotte devrait être situé à un minimum de 20 po (24 po d’une cuisinière à gaz) et un maximum de 30 po au-dessus de la table de cuisson. Deux installateurs sont recommandés lors de l’installation vu la grande dimension et le poids de cette hotte. Afin de réduire les risques d’incendie, assurez-vous d’évacuer l’air à l’extérieur – Ne pas évacuer l’air dans des espaces restreints comme l’intérieur des murs ou plafond ou dans le grenier, faux plafond ou garage. Cet appareil est équipé d’un thermostat pouvant faire démarrer le ventilateur automatiquement. Afin de réduire le risque de blessure, couper le courant à partir du panneau électrique et verrouiller ou apposer un avertissement sur le panneau afin de prévenir que la hotte soit mise en marche automatiquement. À cause de la grande capacité d’évacuation de cette hotte, il est recommandé d’ouvrir une fenêtre dans ou près de la cuisine afin de remplacer l’air évacué. Afin de réduire les risques d’incendie et d’électrocution, la hotte Broan Elite série 64000 doit être installée uniquement avec un des ventilateurs intérieurs Broan suivants : P5 ou P8; un des ventilateurs extérieurs Broan suivants : 331H, 332H, 335 ou 336 ou un des ventilateurs en ligne Broan suivants : HLB3, HLB6, HLB9 ou HLB11 (vendus séparément). Aucun autre ventilateur ne doit être utilisé. Cette hotte ne doit être utilisée qu’avec un ensemble de cordon d’alimentation approuvé. Veuillez consulter l’autocollant apposé à l’intérieur de la hotte pour plus d’information ou autres exigences. - SYSTÈME DE HOTTE DE CUISINIÈRE SÉRIE 64000 VENTILATEURS INTÉRIEURS Modèle 643 Modèle 647 Modèle 634 ou 644 (Capuchon de toit) (Capuchon de mur 7 po rond) (Capuchon de mur 8 po rond) Coude ajustable 8 po rond (optionel) Modèle 415 coude ajustable 7 po rond (optionel) Modèle 407 (Conduit de 7 po rond section de 2 pi) Conduit standard de 8 po rond Modèle 413 transition (31/4 po x 10 po à 8 po) Modèle 412 transition (31/4 po x 10 po à 7 po) Modèle 459 transition 31/4 po x 14 po à 8 po) Conduit standard 31/4 po x 10 po Conduit 31/4 po x 14 po Adaptateur et volet 31/4 po x 10 po (fourni avec ventilateurs P5 et P8) Adaptateur et volet 31/4 po x 14 po (fourni avec ventilateur P8) Déviateur d’air (sortie verticale seulement) (fourni avec les ventilateurs P5 et P8) HOTTE SÉRIE 64000 Plaque ventilateur fournie avec ventilateurs P5 et P8 Modèle P8 ventilateur double (900 pcm) pour hottes de 36 po ou plus Modèle P5 ventilateur simple (500 pcm) NOTE : Le ventilateur double P8 peut être installé autant avec des conduits de 31/4 po x 14 po que des conduits de 31/4 po x 10 po. Pour une performance optimale au niveau sonore et de la ventilation, utiliser des conduits de 31/4 po x 14 po. Dosseret Série RMP (Recouvrement de mur en acier inoxydable avec support assiettes) HL0070 - 19 - - SYSTÈME DE HOTTE DE CUISINIÈRE SÉRIE 64000 VENTILATEURS EN LIGNE ET EXTÉRIEURS Modèle 437 (Capuchon de toit haut rendement) Ventilateur en ligne modèle HLB9 (800 pcm) ou HLB11 (1100 pcm) (incluant deux transitions rondes de 8 po x 12 po à 10 po) Modèle 441 (Capuchon de mur 10 po rond) Ventilateur extérieur modèle 335 (1200 pcm) ou 336 (1500 pcm) Ventilateur extérieur modèle 331H (600 pcm) ou 332H (900 pcm) Modèle 441 (Capuchon de mur 10 po rond) Ventilateur en ligne modèle HLB6 (600 pcm) (incluant deux transitions rondes de 4½ po x 18½ po à 10 po) Modèle 418 Coude ajustable de 10 po (optionnel) Ventilateur en ligne modèle HLB3 (280 pcm) (incluant une transition ronde 8 po à 10 po) Modèle 421 (Volet intérieur 10 po rond vert.) Recommandé pour utilisation avec ventilateurs extérieurs Modèle 410 (Conduit de 10 po rond standard section de 2 pi) HOTTE SÉRIE 64000 Plaque ventilateur 332KR pour ventilateurs extérieurs ou en ligne. Vendue séparément. Dosseret Série RMP (Recouvrement de mur en acier inoxydable avec support assiettes) HL0071 - 20 - 1. SÉLECTIONNER L’OPTION VENTILATEUR ET NSTALLER LES CONDUITS Cette hotte fonctionne autant avec un ventilateur intérieur, en ligne ou extérieur. La hotte de modèle Broan Elite série 64000 doit être installée uniquement avec l’un des ventilateurs suivants : P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 ou 336 (vendus séparément). Aucun autre ventilateur ne peut être utilisé. Déterminer à quel endroit et de quelle façon les conduits seront installés. Si un ventilateur en ligne est installé, se reporter aux directives incluses avec celui-ci et suivre les étapes 1 à 3, 6, 9, 10, 12 et suivantes de ce guide. Installer des conduits de bonnes dimensions, coude(s) et capuchon de mur ou de toit selon le type de ventilateur. Si des conduits circulaires de 7 po ou 8 po sont utilisés, utiliser une transition. Se servir de ruban adhésif en toile de 2 po pour assurer l’étanchéité des joints. La distance minimale entre le bas de votre hotte et la surface de cuisson ne doit pas être plus petite que 20 po (24 po d’une cuisinière à gaz). Un maximum de 30 po au-dessus de la surface de cuisson est fortement recommandé pour une meilleure évacuation des odeurs de cuisine. Une distance de plus de 30 po demeure à la discrétion de l’installateur et de l’utilisateur. Capuchon de toit Capuchon de mur Capuchon de toit Transition de 3¼ po x 14 po à 8 po si conduits de 3¼ po x 14 po Conduits de 3¼ po x 10 po ou de 3¼ po x 14 po Hotte avec ventilateur intérieur Transition de 3¼ po x 10 po à 7 po ou 8 po Hotte Minimum de 20 po au-dessus de la table de cuisson (24 po cuisinière à gaz) HH0029F Conduits ronds de 7 po ou 8 po Capuchon de mur HH0015F INSTALLATION DE CONDUITS RECTANGULAIRES AVEC VENTILATEUR INTÉRIEUR MODÈLE P5 (SIMPLE) OU P8 (DOUBLE) Minimum de 20 po au-dessus de la table de cuisson (24 po cuisinière à gaz) INSTALLATION DE CONDUITS CIRCULAIRES DE 7 PO OU 8 PO AVEC VENTILATEUR INTÉRIEUR MODÈLE P5 (SIMPLE) OU P8 (DOUBLE) Capuchon de toit Ventilateur extérieur Ventilateur extérieur Conduits ronds de 10 po Ventilateur en ligne Conduits ronds de 10 po Capuchon de mur Hotte HH0016F Minimum de 20 po au-dessus de la table de cuisson (24 po cuisinière à gaz) HH0060F INSTALLATION TYPIQUE AVEC VENTILATEUR EXTÉRIEUR MODÈLE 331H, 332H, 335 OU 336 Hotte Minimum de 20 po au-dessus de la table de cuisson (24 po, cuisinière à gaz) INSTALLATION TYPIQUE AVEC VENTILATEUR EN LIGNE MODÈLE HLB3, HLB6, HLB9 OU HLB11 - 21 - 2. PRÉPARER L’INSTALLATION S’assurer que les items suivants sont inclus : - Hotte - Accessoires : • Filtres • Sac de pièces incluant: (4) écrous dentelés, (1) serre-fils, (8) vis 1/2 po à double filets, (2) connecteurs (genre «marette»), (2) vis 1/2 po standard, (6) vis 3/8 po standard Pièces vendues séparément : - Ventilateur interne modèle P5 incluant ventilateur, plaque ventilateur, déviateur et adaptateur 31/4 po x 10 po - Ventilateur interne modèle P8 incluant ventilateur, plaque ventilateur, déviateur et adaptateur 31/4 po x 10 po et adaptateur 31/4 po x 14 po - Ensemble de ventilateur el ligne modèle HLB3, HLB6, HLB9 ou HLB11 (tous incluant la transition) - Ensemble ventilateur extérieur modèles 331H, 332H, 335 ou 336 - Plaque ventilateur en ligne ou extérieur modèle 332KR (requise pour tous les modèles de ventilateurs en ligne ou extérieurs) - Ampoules halogènes (120V, 50W, PAR 20) - Lampes chauffantes (120V, IR 175W, PAR 38) - Dosseret (optionnel) - Filtres à chicanes (optionnels) - Transitions, conduits, coudes, volets, capuchons de mur ou de toit. Consuler les pages 19 et 20 pour la liste complète des accessoires de ventilation et les numéros de modèle. NOTE: Si le fond de l’armoire est en retrait, y fixer des baguettes de bois (non incluses) de chaque côté. Pour une hotte de 30 po de largeur, se servir de deux (2) baguettes de 2 po de largeur, et pour une hotte plus large, se servir de 4 baguettes, de longueur appropriée. Voir ci-dessous pour la localisation des baguettes. LARGEURS 30 36 42 48 PO PO PO PO LOCALISATIONS B C PO S/O S/O PO 41/2 PO 41/2 PO PO 71/4 PO 81/4 PO PO 101/4 PO 111/4 PO A DE HOTTES 2 2 2 4 A HD0079 A B C 3. INSTALLER LE DOSSERET (OPTIONNEL) Le dosseret doit être installé avant la hotte puisque celle-ci couvre les vis d’installation du dosseret. Afin de pouvoir installer le dosseret, s’assurer d’avoir 18 po entre le dessous de la hotte et le panneau de contrôle de la cuisinière ou de la surface de cuisson. (Voir instructions fournies avec le dosseret.) 4. SÉLECTIONNEZ L’OPTION VENTILATEUR (EXTÉRIEUR OU INTÉRIEUR) VENTILATEUR INTÉRIEUR : Suivre toutes les étapes subséquentes de ce guide. VENTILATEUR EXTÉRIEUR : Voir les instructions fournies avec le ventilateur extérieur et suivre les étapes 6, 10, 12 et suivantes du présent guide. - 22 - 5. CHOISIR L’OUVERTURE (VENTILATEUR INTÉRIEUR) Enlever l’ouverture préamorcée choisie pour la sortie d’air de la hotte (horizontale à l’arrière de la hotte ou verticale sur la plaque du ventilateur). Voir les photos ci-dessous. ATTENTION Si un ventilateur P5 est installé, enlever l’ouverture préamorcée de 10 po de largeur (la plus petite). Si un ventilateur P8 est installé, retirer l’ouverture préamorcée de largeur correspondante aux conduits (10 po ou 14 po). rture Ouve po de 14 Ouverture de 14 po Ouverture de 10 po re ertu Ouv 0 po de 1 HD0076 HD0077 Retrait de l’ouverture préamorcée à l’arrière de la hotte Retrait de l’ouverture préamorcée sur la plaque du ventilateur 6. INSTALLER LA PLAQUE VENTILATEUR (TOUS LES VENTILATEURS) VENTILATEUR INTÉRIEUR : Installer la plaque (incluse avec les ventilateurs P5 et P8) à l’intérieur de la hotte en utilisant 4 écrous dentelés. Voir la photo ci-dessous. HD0042 VENTILATEUR EXTÉRIEUR OU EN LIGNE : Voir les instructions incluses avec l’ensemble de plaque ventilateur de modèle 332KR (vendu séparément). Installer la plaque à l’intérieur de la hotte en utilisant 4 écrous dentelés. 7. INSTALLER LE DÉVIATEUR (VENTILATEUR INTÉRIEUR) Si la hotte est installée de façon à évacuer l’air verticalement, le déviateur doit être installé. Installer le déviateur tel qu’illustré. NOTE : Il est normal que le déviateur n’entre pas entièrement dans la hotte, il dépasse d’environ 1/8”. HD0003 Insertion du déviateur dans l’ouverture verticale - 23 - 8. INSTALLER L’ ADAPTATEUR (VENTILATEUR INTÉRIEUR) En utilisant les 2 vis standard 1/2 po, installer l’adaptateur sur le dessus (ou à l’arrière) de la hotte. Sceller ensuite l’adaptateur à l’aide de ruban adhésif en toile. HD0005 HD0006 9. INSTALLER LA HOTTE (TOUS LES VENTILATEURS) VENTILATEUR INTÉRIEUR : Passer l’alimentation électrique jusqu’à l’endroit de l’installation de la hotte. Placer la hotte à son emplacement. Marquer la position des vis (petite partie du trou en forme de poire) à l’aide d’un crayon. Retirer la hotte et installer les 8 vis 1/2 po double filets en laissant un espace de 1/8 po (4 vis pour la hotte de 30 po). Enlever le couvercle de la boîte électrique et y insérer le serre-fils. Passer le câble électrique dans la hotte et serrer la vis du serre-fils à l’entrée de la hotte pour maintenir les fils en place. Placer la hotte sous l’armoire (les vis passent à travers la grosse partie des trous) et glisser la hotte en position. S’assurer que l’adaptateur entre dans le conduit. Visser complètement les vis pour maintenir la hotte en position. HD0043 VENTILATEUR EN LIGNE OU EXTÉRIEUR : Passer l’alimentation électrique jusqu’à l’endroit de l’installation de la hotte. Placer la hotte à son emplacement. Marquer la position des vis (petite partie du trou en forme de poire) à l’aide d’un crayon. Retirer la hotte et installer les 8 vis 1/2 po double filet en laissant un espace de 1/8 po (4 vis pour la hotte de 30 po). Enlever le couvercle de la boîte électrique située sur le dessus de la hotte et effectuer le branchement électrique (voir les instructions incluses avec le ventilateur en ligne ou extérieur). Placer la hotte sous l’armoire (les vis passent à travers la grosse partie des trous) et glisser la hotte en position. Visser complètement les vis pour maintenir la hotte en position. - 24 - 10. BRANCHEMENTS ÉLECTRIQUES (TOUS LES VENTILATEURS) ! AVERTISSEMENT Risque d’électrocution. Le raccordement électrique doit être effectué par du personnel qualifié conformément aux codes et standards. Avant d’effectuer le branchement, coupez l’alimentation électrique au panneau de service et verrouillez-le pour éviter une mise en marche accidentelle. VENTILATEUR INTÉRIEUR : Connecter les fils à la boîte électrique en utilisant les connecteurs. Connecter le fil NOIR au NOIR, le BLANC au BLANC et le VERT ou DÉNUDÉ à la vis de mise à la terre. Refermer le couvercle. NE PAS OUBLIER DE CONNECTER LA MISE À LA TERRE. HD0007 1 1) Vis de mise à la terre VENTILATEUR EN LIGNE OU EXTÉRIEUR : Enlever le couvercle de la boîte électrique de la plaque ventilateur et effectuer le branchement électrique (voir les directives incluses avec le ventilateur en ligne ou extérieur). 11. INSTALLER LE VENTILATEUR (VENTILATEUR INTERNE) Le ventilateur doit être installé à la plaque ventilateur en utilisant 4 vis 3/8 po pour le ventilateur simple et 6 vis 3/8 po pour le ventilateur double. Enlever le couvercle du ventilateur. Enlever ensuite la ou les roue(s) du ventilateur en tirant délicatement (voir photos ci-dessous). HD0022 HD0021 - 25 - 11. INSTALLER LE VENTILATEUR (VENTILATEUR INTERNE) (SUITE) Installer les vis aux endroits indiqués sur les photos ci-dessous (ventilateur simple ou double) en laissant un espace d’environ 1/8 po. Accrocher ensuite le ventilateur à la plaque ventilateur (passer les têtes de vis à travers la grande partie des trous). Glisser ensuite le ventilateur en position (les têtes de vis dans la petite partie des trous). Serrer complètement les vis. HD0044 HD0044 Ventilateur double (P8) Ventilateur simple (P5) Terminer la fixation du ventilateur à l’aide de 2 autres vis aux endroits indiqués sur les photos ci-dessous (ventilateur simple ou double). Remettre en place la ou les roue(s) de ventilateur et le couvercle. HD0080 HD0081 Ventilateur simple (P5) Ventilateur double (P8) DEVANT HD0023 2 1 POUR LE VENTILATEUR DOUBLE, S’ASSURER QUE LES ROUES SONT CORRECTEMENT REPLACÉES; LA HOTTE NE FONCTIONNERA PAS NORMALEMENT SI INVERSÉES. Les ventilateurs doubles possèdent deux roues différentes; une doit tourner dans le sens des aiguilles d’une montre et l’autre dans le sens contraire des aiguilles d’une montre. Chaque roue et moteur portent une flèche et un numéro, vous devez les assortir correctement. (Voir dessin ci-contre.) 1 2 HD0023 ! AVERTISSEMENT Ne jamais brancher le fil élecrique du ventilateur à la prise femelle du cordon d’alimentation. A Brancher le cordon de la boîte électrique (A) et le ventilateur (B) aux prises derrière le panneau de contrôle à l’intérieur de la hotte. HE0003 - 26 - B 12. AMPOULES HALOGÈNES Cette hotte de cuisinière utilise des ampoules halogènes de 50W (120V, 50W, PAR 20). Installer les ampoules en les tournant dans le sens des aiguilles d’une montre. 13. LAMPES CHAUFFANTES Les lampes chauffantes requises sont des ampoules infrarouges de 175W max. (120V, IR175W, PAR 38). Vous pouvez utiliser des ampoules halogènes blanches si les tablettes réchauds ne sont pas utilisées (120V, 90W, PAR 38). Installer les ampoules en les tournant dans le sens horaire. 14. INSTALLER LES FILTRES Il est recommandé d’installer d’abord les filtres situés aux extrémités et de terminer par le(s) filtre(s) du centre. INSTALLATION DES FILTRES 1. 2. 3. 4. Des Insérer la partie supérieure du filtre dans la hotte. (côté de la languette) Faire pivoter la partie inférieure vers l’intérieur de la hotte. Placer le filtre sous l’attache située au fond de la hotte. En tirant sur sa languette, glisser le dessus du filtre sous la pièce de retenue intérieure. filtres à chicanes sont disponibles en option. (Voir la feuille d’installation incluse avec les filtres à chicane.) HD0009 HD0010 1 1) Languettes 15. ENTRETIEN Filtres et roue de ventilateur. Les filtres, la gouttière et la ou les roue(s) de ventilateur doivent être fréquemment nettoyés. Utiliser de l’eau chaude additionnée de détergent. Les filtres et les roues peuvent être nettoyés au lave-vaisselle. Pousser les filtres vers l’intérieur de la hotte et les désengager de la gouttière pour ensuite les retirer de la hotte. - 27 - 15. ENTRETIEN (SUITE) Nettoyage de la hotte Acier inoxydable : Comment maintenir son apparence étincelante À faire : - Laver régulièrement les surfaces à l’aide d’un chiffon ou linge propre imbibé d’eau tiède et de savon doux ou détergent à vaisselle. - Toujours nettoyer dans la direction des lignes de grains (direction du polissage). - Toujours bien rincer avec de l’eau propre (2 ou 3 fois) après le nettoyage et essuyer complètement. - Un nettoyant domestique conçu spécialement pour l'acier inoxydable peut aussi être utilisé. À ne pas faire : - N’utiliser aucune laine d’acier ou d’acier inoxydable ou tout autre grattoir pour enlever la saleté tenace. - N’utiliser aucune poudre nettoyante abrasive ou rugueuse. - Ne pas laisser la saleté s’accumuler. - Ne pas laisser la poussière de plâtre ou tout autre résidu de construction/rénovation atteindre la hotte. Couvrir la hotte pour la durée des travaux pour s’assurer qu’aucune poussière ne colle à la surface de l’acier. À éviter lors du choix d’un détergent : - Tous produits nettoyants qui contiennent des agents de blanchiment; ils attaqueront l’acier inoxydable. - Tous produits contenant du chlorure, fluorure, iode ou bromure; ils détérioreront rapidement les surfaces. - Tous produits combustibles utilisés pour le nettoyage : acétone, alcool, éther, benzol, etc.; ils sont hautement explosifs et ne devraient jamais être utilisés près d’une cuisinière. Surfaces peintes : Nettoyer avec de l’eau chaude additionnée seulement d’un détergent doux. S’il y a décoloration, utiliser une bonne cire à peinture telle qu’une cire d’automobile. (NE PAS UTILISER de nettoyant abrasif rugueux ou de nettoyant à porcelaine.) 16. FONCTIONNEMENT Toujours mettre en marche la hotte avant de commencer la cuisson afin d’établir une circulation d’air dans la cuisine. Laisser également la hotte fonctionner quelques minutes après l’arrêt de la cuisinière afin de nettoyer l’air. Ceci aidera à garder la cuisine plus propre et plus claire. 1 1 HC0028 2 3 4 1) Interrupteurs des lampes chauffantes 2) Interrupteurs des ampoules halogènes 3) MARCHE/ARRÊT du ventilateur 4) Contrôle de la vitesse du ventilateur VENTILATEUR Le ventilateur fonctionne à l’aide de deux contrôles. Utiliser l’interrupteur marche/arrêt muni d’une lumière rouge pour mettre en marche et arrêter le ventilateur. Lorsque mis sous tension, le ventilateur fonctionnera à la vitesse utilisée la dernière fois. Utiliser le contrôle de vitesse du ventilateur en tournant dans le sens des aiguilles d’une montre pour diminuer la vitesse et dans le sens contraire des aiguilles d’une montre pour augmenter la vitesse. AMPOULES HALOGÈNES Deux interrupteurs marche/arrêt contrôlent les lampes halogènes. L’interrupteur à bascule avant contrôle la lampe du centre (pour les hottes de 42 po et 48 po). L’interrupteur arrière contrôle les ampoules de chaque côté (chaque interrupteur contrôle une ampoule pour les hottes de 30 po et 36 po). Allumer une, deux ou trois ampoules selon vos besoins. Utiliser des ampoules halogènes PAR 20, 50W. - 28 - 16. FONCTIONNEMENT (SUITE) ! AVERTISSEMENT Ne jamais placer de matière inflammable sous les lampes chauffantes. LAMPES CHAUFFANTES (INFRAROUGES) Chaque lampe est contrôlée indépendamment par son propre interrupteur. Utiliser des ampoules infrarouges (120V, IR175W, PAR38) ou des ampoules halogènes (120V, 90W, PAR38) si les tablettes servant au réchaud d’aliments ne sont pas utilisées. HEAT SENTRY Votre hotte est équipée d’un capteur de température appelé Heat Sentry. Ce capteur actionnera automatiquement le ventilateur de la hotte ou augmentera sa vitesse s’il détecte de la chaleur excessive au-dessus de la surface de cuisson. 1) Si le ventilateur n’est pas en marche – il met le ventilateur en marche à haute vitesse. 2) Si le ventilateur est en marche à une vitesse inférieure – il met le ventilateur à vitesse maximum. ! AVERTISSEMENT Le HEAT SENTRY peut entrer en fonction même si la hotte est arrêtée. Dans ce cas, il est impossible d’arrêter le ventilateur avec son interrupteur. Si vous devez arrêter la hotte, faites-le à partir du panneau électrique principal. Lorsque la température revient à la normale, la vitesse du ventilateur retourne à sa position originale. GARANTIE GARANTIE LIMITÉE D’UN AN DE BROAN-NUTONE LLC Broan-NuTone LLC garantit à l’acheteur consommateur initial de ses produits qu’ils sont exempts de tout défaut dans les matières premières ou la main-d’œuvre, pour une période d’un an à compter de la date d’achat par le consommateur initial. IL N’Y A PAS D’AUTRES GARANTIES, EXPRIMÉES OU IMPLICITES, INCLUANT, MAIS NON LIMITÉES AUX GARANTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE DANS UN BUT PARTICULIER. Durant cette période d’un an, Broan-NuTone LLC, à sa discrétion, réparera ou remplacera gratuitement, tout produit ou pièce qui s’avère défectueux et ayant été utilisé nomalement et d'une manière non abusive. Cette garantie ne couvre pas (a) l’entretien et le service normal ou (b) tout produit ou pièce endommagé par suite de mauvais usage, négligence, accident, entretien inapproprié ou réparation (autre que par Broan-NuTone LLC), mauvaise installation ou installation non conforme au mode d’installation recommandé. La durée de toute garantie implicite est limitée à une période d’un an tel que spécifiée pour la garantie exprimée. Certains états ou provinces ne permettent pas de limite de temps sur les garanties implicites. Si tel est le cas, veuillez ne pas tenir compte de la dernière limite décrite ci-dessus. L’ENGAGEMENT DE BROAN-NUTONE LLC DE RÉPARER OU DE REMPLACER, AU CHOIX DE BROANNUTONE LLC, SERA LA SEULE OBLIGATION EXCLUSIVE SOUS CETTE GARANTIE. BROAN-NUTONE LLC NE SE TIENDRA PAS RESPONSABLE DES DOMMAGES DIRECTS, INDIRECTS OU SPÉCIAUX SURVENANT À CAUSE DE OU EN RAPPORT À L’UTILISATION OU LA PERFORMANCE DE SES PRODUITS. Certains états ou provinces ne permettent pas l’exclusion ou la limite relative aux dommages directs, indirects ou spéciaux. Si tel est le cas, veuillez ne pas tenir compte de l’exclusion ou de la limite ci-dessus. Cette garantie vous donne des droits légaux spécifiques et il se peut que vous ayez d’autres droits qui varient d’un état ou d’une province à l’autre. Cette garantie annule toutes les autres garanties précédentes. Pour le service sous garantie, vous devez (a) aviser Broan-NuTone LLC à l’une des adresses ou numéros de téléphone mentionnés plus bas, (b) donner le numéro du modèle et l’identification de la pièce et (c) décrire la nature de tout défaut dans le produit ou la pièce. Au moment de la demande de service sous garantie, vous devez présenter une preuve de la date d’achat initial du dit produit. Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626) - 29 - PIÈCES DE REMPLACEMENT Série 64000 1 2 18 2 20 17 17 19 3 7 12 6 5 13 4 15 16 14 17 17 17 8 2 9 10 11 2 8 HL0002 N° REF. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 N° DE LA PIÈCE V06750 V02264 V02773 V02772 V03435 V03436 V03501 V03507 V03502 V03503 V03504 V03505 V03517 V03518 V03519 V03520 V00673 V02512 V01869 V01582 V00606 V03509 V03510 V13216 V13217 V13218 V13219 V03686 V02544 V03598 V03515 V13278 DESCRIPTION LOGO BROAN ELITE DOUILLE CONNECTEUR MÂLE CONNECTEUR FEMELLE THERMOSTAT SUPPORT POUR THERMOSTAT CONTRÔLE DE VITESSE INTERRUPTEUR SIMPLE UPST POUR LAMPE CHAUFFANTE INTERRUPTEUR DOUBLE UPST POUR LAMPES HALOGÈNES INTERRUPTEUR SIMPLE ILLUMINÉ UPST POUR VENTILATEUR BOUTON DE CONTRÔLE DE VITESSE PLAQUE À BORNES FILS D’ALIMENTATION 10 po FILS LAMPES RÉCHAUD 10 po FIL DE CONTRÔLE 10 po FIL INTERRUPTEUR ILLUMINÉ 10 po ÉCROU DENTELÉ N° 8-32 VIS N° 8-32 x 1/2 po QUADREX VIS MÉCANIQUE N° 6-32 x 1/4 po ÉCROU DENTELÉ N° 6-32 VIS N° 8- 3/8 poT/B TÊTE N° 8 FILTRE RANGEMASTER 8,930 po x 9,800 po FILTRE RANGEMASTER 11,930 po x 9,800 po GOUTTIÈRE 30 po GOUTTIÈRE 36 po GOUTTIÈRE 42 po GOUTTIÈRE 48 po ATTACHE FILTRE AMPOULE HALOGÈNE PAR 20 50 W LAMPE CHAUFFANTE GUIDE D’INSTALLATION SAC D’INSTALLATION ((4) écrous à bride n° 10-32, (1) serre-fil LP16-AP, (2) connecteurs n° 74B, (8) vis double filets 6-12 x 0,5 po, (6) vis n° 8 x 3/8 po, (2) vis n° 6 x 1/2 po) - 30 - QTÉ (largeur de hotte) 30 po 36 po 42 po 48po 1 1 1 1 4 4 5 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 7 7 8 8 2 2 1 3 2 4 1 1 1 1 3 3 4 4 2 2 3 3 2 2 2 2 1 1 1 1 1 1 1 1 PIÈCES DE REMPLACEMENT PLAQUE ET VENTILATEUR SIMPLE (Modèle P5) 1 20 21 2 23 22 19 3 4 17 5 6 18 16 15 14 13 6 7 8 12 9 11 10 HL0021 N° RÉF. N° DE LA PIÈCE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 V13296 V03500 V12997 V03577 V02160 V01869 V01857 V01582 V14973 V01810 V03400 V01766 V00871 V02001 V01831 V11705 V11614 V01927 V03495 V03494 V13230 V03496 V00660 V05520 V00613 15 16 17 18 19 20 21 22 23 DESCRIPTION ADAPTATEUR ET VOLET 3 /4 po x 10 po DÉFLECTEUR D’AIR PLAQUE VENTILATEUR SIMPLE ASSEMBLÉE MOUSSE 1/2 po x 1/2 po x 12 po CONDENSATEUR 15MFD VIS MÉCANIQUE N° 6-32 x 1/4 po CACHE-FILS ÉCROU DENTELÉ N° 6-32 VENTILATEUR SIMPLE ASSEMBLÉ ANNEAU ROUE ROUE HOTTE 7,09 po x 3,37 po CW MOTEUR 165W CW RONDELLE 3/16 po DI x 3/4 po DE OEILLET MOTEUR G-431-1 COLLIER DE SERRAGE 8 po SUPPORT DE MOTEUR FIL N° 18 TEW BRUN x 10 po VIS MÉTRIQUE M4 x 6mm PAN QDRX ARRÊT DE TRACTION CORDON VENTILATEUR CORDON D’ALIMENTATION VENTILATEUR 36 po PORTE CONNEXION ÉLECTRIQUE CORDON D’ALIMENTATION 120 VOLTS ARRÊT DE TRACTION CORDON D’ALIMENTATION VIS N° 8 x 3/8 po, T/B, TÊTE N° 8 VIS N°10-32 x 3/8 po, TF, VERTE 1 - 31 - QTÉ 1 1 1 1 1 4 1 1 1 3 1 1 3 3 2 1 1 4 1 1 1 1 1 2 2 PIÈCES DE REMPLACEMENT PLAQUE ET VENTILATEUR DOUBLE (Modèle P8) 2 1 25 3 4 24 23 22 21 5 19 18 17 16 15 14 6 7 8 11 20 9 13 10 12 N° RÉF. N° DE LA PIÈCE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 V14971 V13296 V03500 V14975 V03577 V01582 V02160 V01857 V01766 V03400 V14974 V01810 V03399 V03457 V00871 V01831 V11705 V11614 V02001 V01927 V03495 V03494 V14960 V00660 V03496 V0520 V00613 16 17 18 19 20 21 22 23 24 25 DESCRIPTION ADAPTATEUR ET VOLET 31/4 po x 14 po ADAPTATEUR ET VOLET 31/4 po x 10 po DÉFLECTEUR D’AIR PLAQUE VENTILATEUR DOUBLE ASSEMBLÉE MOUSSE 1/2 po x 1/2 po x 12 po ÉCROU DENTELÉ NO 6-32 CONDENSATEUR 15MFD CACHE-FILS MOTEUR 165W CW ROUE HOTTE 7,094 po x 3,375 po CW VENTILATEUR DOUBLE ASSEMBLÉ ANNEAU ROUE ROUE HOTTE 7,094 po x 3,375 po CCW MOTEUR 165W CCW RONDELLE 3/16 po DI x 3/4 po DE COLLIER DE SERRAGE 8 po SUPPORT DE MOTEUR FIL N° 18 TEW BRUN X 10 po OEILLET MOTEUR G-431-1 VIS MÉTRIQUE M4 x 6mm PAN QDRX ARRÊT DE TRACTION CORDON DE VENTILATEUR CORDON D’ALIMENTATION VENTILATEUR 36 po PORTE CONNEXION ÉLECTRIQUE ARRÊT DE TRACTION CORDON D’ALIMENTATION CORDON D’ALIMENTATION 120 VOLTS VIS N° 8 X 3/8”, T/B, TÊTE N° 8 VIS N° 10-32 X 3/8, TF, VERTE - 32 - QT 1 1 1 1 1 1 2 2 1 1 1 2 1 1 6 2 2 2 6 8 1 1 1 1 1 4 2 MANUAL DE INSTALACIÓN HB0056 SERIE 64000 ! CONCEBIDO SÓLO PARA USO DOMÉSTICO ! LEER Y CONSERVAR ESTAS INSTRUCCIONES INSTALADOR: DEJAR ESTE MANUAL AL PROPRIETARIO. PROPIETARIO: INSTRUCCIONES DE UTILIZACIÓN Y MANTENIMIENTO EN LAS PÁGINAS 43 A 45 Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626) REGISTRE SU PRODUCTO EN LÍNEA EN: www.broan.com/register V03515 rev. J ! ADVERTENCIA ! ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA, O LESIONES A PERSONAS, CUMPLA LOS SIGUIENTES PUNTOS: PARA EVITAR RIESGO DE LESIONES PERSONALES EN CASO DE INCENDIO DE GRASA EN LA SUPERFICIE DE LA ESTUFA, OBSERVE LO SIGUIENTE*: 1. Solamente use esta unidad de la manera propuesta por el fabricante. Si tiene alguna pregunta, comuniquese con el fabricante en la dirección o teléfono anotados en la garantía. 1. 2. Antes de limpiar o poner en servicio la unidad, apague el interruptor en el panel de servicio, y asegure el panel de servicio para evitar que se encienda accidentalmente. Cuando el dispositivo para desconectar el servicio eléctrico no puede ser cerrado con algún tipo de traba, sujete fuertemente al panel de servicio, una etiqueta de advertencia prominente. 3. El trabajo de instalación y el alambrado eléctrico deben llevarse a cabo por personal calificado de acuerdo con todos los códigos y las normas aplicables, incluyendo los códigos y normas de construcción contra incendios. 4. Se requiere una cantidad de aire suficiente para la combustión y escape de gases por la chimenea del equipo de quemado de combustible para evitar salirse de las especificaciones y estándares de seguridad del fabricante, tales como los publicados por la Asociación nacional de protección contra incendios (NFPA por sus siglas en Inglés), y la Sociedad americana de ingenieros de calefacción, refrigeración y aire acondicionado (ASHRAE por sus siglas en Inglés), y los códigos de las autoridades locales. Cubra y sofoque las llamas con una tapa ajustada, azafate de hornear galletas, o azafate de metal, y luego apague el calentador. TENGA CUIDADO PARA EVITAR QUEMADURAS. Si la llamas no se apagan inmediatamente, HAY QUE EVACUAR Y LLAMAR LOS BOMBEROS. 2. NUNCA ALCE UNA SARTÉN QUE TENGA LLAMAS – Usted se puede quemarse. 3. NO USE AGUA, incluyendo trapos, lavaplatos mojados o toallas - puede que ocurran explosiones de vapor violentas. 4. Use un extintor SOLAMENTE si : A. Usted sabe que tiene un extintor ABC y sabe usarlo. B. El incendio es pequeño y está restringido al área donde empezó. C. Se está llamando los bomberos. D. Usted puede tratar de apagar el fuego teniendo una salida detrás suyo. * Basado en “Kitchen Fire Safety Tips” publicado por la Asociación National de protección contra Incendios (NFPA). PRECAUCIÓN 1. 2. 5. Cuando corte o taladre en una pared o techo, no dañe los cables eléctricos ni otras instalaciones ocultas. 6. Los ventiladores con conductos deben siempre ventilar hacia el exterior. 7. No use esta unidad con ningún otro control de velocidad de estado sólido. 8. Para reducir todo riesgo de incendio, use solamente conductos en metal. 5. 9. Esta unidad se debe conectar a tierra. 6. 3. 4. PARA REDUCIR EL RIESGO DE INCENDIO DE GRASA EN LA SUPERFICIE DE LA ESTUFA: a) No deje nunca los aparatos de cocer sin vigilancia a fuego vivo. Los desbordamientos producen humo y derrames grasiendos que pueden inflamarse. Caliente el aceite despacio, a fuego lento o mediano. b) Ponga en marcha siempre la campana al cocinar a temperaturas elevadas o al cocinar alimentos flameados. c) Limpie los ventiladores con frecuencia. No deje que la grasa se acumule en el ventilador ni en el filtro. d) Utilice cacerolas de tamaño apropiado. Emplee siempre un recipiente adecuado para el tamaño de la placa. 7. 8. 9. 10. 11. - 34 - Sólo para uso de ventilación general. No se use para extraer materiales o vapores peligrosos o explosivos. Para evitar daños al cojinete del motor y/o impulsores ruidosos o desequilibrados, mantenga la fuente de potencia lejos de rocíos de pared seca, de polvo de construcción, etc. El motor de la campana tiene un dispositivo contra sobrecargas térmicas que apaga el motor en forma automática si éste se sobrecalienta. El motor volverá arrancar cuando se enfríe. Si el motor sigue apagándose, haga verificar campana reciba servicio. Para lograr una mejor captura de las impurezas producidas al cocinar, la parte inferior de la campana deberá estar a un mínimo de 20” (24” de una cocina a gas) y un máximo de 30” sobre el nivel la superficie para cocina. Se recomienda que la instalación la realicen dos personas, debido al tamaño y peso de esta campana. A fin de reducir los riesgos de incendio y para bien evacuar el aire de salida, asegúrese de evacuar el aire al exterior – No evacue el aire en espacios limitados como el interior de las paredes o del techo o en el desván, falso techo o garaje. Este producto está equipado de un termostato que puede hacer partir el ventilador automáticamente. Para evitar los riesgos de daño, apague la corriente del panel eléctrico y cierre con candado o afiche una advertancia en el panel para prevenir que la campana funcione automáticamente. A causa de la gran capacidad de evacuación de esta campana, usted debe asegurarse que suficiente aire entre en la casa para remplazar el aire evacuado abriendo una ventana a el interior o cerca de la cocina por ejemplo. Para reducir el riesgo de incendio y descarga eléctrica, este campana Broan Elite serie 64000 debe ser instalada con ventilador interior modelo P5 o P8, ventilador exterior modelo 331H, 332H, 335 o 336 o ventilador en línea HLB3, HLB6, HLB9 o HLB11 (vendidos separadamente) solamente. Otros ventiladores no pueden reemplazar a este ventiladores. Utilíce sólo con un conjunto autorizado de conexión con cordón. Lea la etiqueta de especificaciones en el producto para mayor información y requisitos. - SERIE 64000 SISTEMA DE LA CAMPANA DE COCINA VENTILADORES INTERIORES Modelo 643 Modelo 647 7” redondo (remate de pared) Modelo 634 ó 644 (remate de techo) (remate de pared 8” redondo) Codo ajustado de 8” (opcional) Modelo 415 Codo ajustado de 7” (opcional) Conducto estándar de 8” redondo Modelo 407 conducto redondo de 7” (Sectiones de 24’’) Modelo 413 transicíon (31/4” x 10” a 8”) Modelo 412 transicíon 31/4” x 10” a 7” Conducto estándar 31/4” x 10” Modelo 459 transicíon (31/4” x 14” a 8”) Conducto 31/4” x 14” Adaptador & compuerta 31/4” x 10” (incluye con ventiladores P5 y P8) Adaptador & compuerta 31/4” x 14” (incluye con ventilador P8) Deflertor de aire (incluye con ventiladores P5 y P8) CAMPANA SERIE 64000 Bandeja de conexión (incluye el ventiladores interiores P5 y P8) Modelo P5 ventilador simple (500 pcm) Modelo P8 ventilador doble (900 pcm) para campanas de 36’’ o más anchas NOTA: El ventilador doble P8 puede ser instalado con conductos de 31/4” x 14’’ o 31/4” x 10”. Para prestaciones óptima a nivel de sonido y del aire, utilizar los conductos 31/4” x 14”. Placa antisalpicaduras Serie RMP (Cubierta para pared de acero inoxidable con estantes para calentamiento. Opcional.) HL0070 - 35 - - SERIE 64000 SISTEMA DE LA CAMPANA DE COCINA VENTILADORES EN LÍNEA Y EXTERIORES Modelo 437 (Remate de techo alta capacidad) Ventilador en línea modelo HLB9 (800 pcm) ó HLB11 (1100 pcm) (incluye dos transiciones redondas de 8” x 12” a 10”) Modelo 441 (Remate de pared Ventilador exterior 10” redondo) modelo 335 (1200 pcm) Ventilador exterior ó 336 (1500 pcm) modelo 331H (600 pcm) ó 332H (900 pcm) Modelo 441 (Remate de pared 10” redondo) Ventilador en línea modelo HLB6 (600 pcm) (incluye dos transiciones redondas de 4½” x 18½” a 10”) Modelo 418 Codo ajustado de 10” (opcional) Ventilador en línea modelo HLB3 (280 pcm) (incluye una transición redonda de 8” a 10”) Modelo 421 (10” Redondo. vertical, en línea interior) Recomandado para utilización con ventiladores exteriores Modelo 410 conducto de 10” redondo (Sectiones de 2’) CAMPANA SERIE 64000 Bandeja de conexión 332KR para ventiladores exteriores ó en línea. Vendida separadamente. Placa antisalpicaduras Serie RMP (Cubierta para pared de acero inoxidable con estantes para calentamiento. Opcional.) HL0071 - 36 - 1. SELECCIONE LA OPCIÓN VENTILADOR Y INSTALE LOS CONDUCTOS Esta campana funciona tanto con un ventilador exterior, con un ventilador en línea y como interior. La campana de modelo Broan Elite serie 64000 debe ser instalado unicamente con ventilador modelo P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 o 336 (vendidos separadamentes). Otros ventiladores no pueden reemplazar a este ventiladores. Planifique dónde y como se van a colocar los conductos. Si un ventilador en línea est instalado, se refiere a las instrucciones incluidas con ésté y siga las etapas 1 a 3, 6, 9, 12 y siguiente de este manual. Instale los conductos de dimensión adecuada, codo(s) y remate la pared o el techo adecuado para el tipo de ventilador que esté usando. Si usted elige conductos circulares de 7” ó 8”, utilice una transición. Utilice cinta adhesiva a conducto para asegurarse estanquidad de las coyunturas. La distancia mínima entre la campana y la encimera debe ser de 20” (24’’ para una cocina a gas). Asimismo, se recomienda que dicha distancia so supere las 30’’ para obtener la máxima capacidad de absorción de las impurezas creadas al cocinar. Si se utilizan distancias superiores a 30”, el instalador y el usuario son responsables de los posibles problemas. Tapa del techo Tapa del techo Tapa del muro Transición de 3¼” x 14” a 8” si conducto de 3¼” x 14” Conducto estándar de 3¼” x 10” o de 3¼” x 14” Conducto redondo 7” o 8” Tapa del muro Campana con ventilador interior HH0029E Distancia mínima de 20” sobre el nivel de la superficie para cocinar (24’’ para cocina a gaz) HH0015E INSTALACIÓN CON CONDUCTO RECTANGULAR CON VENTILADOR INTERIOR MODELO P5 (SIMPLE) Ó P8 (DOBLE) Transición 3¼” x 10” a 7” o 8” Campana Distancia mínima de 20” sobre el nivel de la superficie para cocinar (24’’ para cocina a gaz) INSTALACIÓN CON CONDUCTO REDONDO DE 7’’ Ó 8’’ CON VENTILADOR INTERIOR MODELO P5 (SIMPLE) Ó P8 (DOBLE) Tapa del techo Ventilador exterior Ventilador exterior Conducto redondo de 10” Ventilador en línea Conducto redondo 10” Tapa del muro Campana Campana HH0016E Distancia mínima de 20” sobre el nivel de la superficie para cocinar (24’’ para cocina a gaz) Distancia mínima de 20” sobre el nivel de la superficie para cocinar (24’’ para cocina a gaz) HH0060E INSTALACIÓN ESTÁNDAR CON VENTILADOR EXTERIOR MODELO 331H, 332H, 335 Ó 336 INSTALACIÓN ESTÁNDAR CON VENTILADOR EN LÍNEA MODELO HLB3, HLB6, HLB9 Ó HLB11 - 37 - 2. PREPARE LA INSTALACIÓN Asegúrese que los artículos siguientes están incluidos: - Campana - Accesorios: • Filtros • Bolsa de piezas incluye: (4) tuercas dentellado, (1) alambre eléctrico, (8) 1/2” tornillos a doble hilillo (2) conectador de cable, (2) 1/2” tornillos estàndar, (6) 3/8” tornillos Piezas separadas: - Ventilador interno modelo P5 incluye ventilador interno, placa del ventilador, desviador y adaptador 31/4” x 10” - Ventilador interno modelo P8 incluye ventilador interno, placa del ventilador, desviador y adaptador 31/4” x 10” y adaptador 31/4” x 14” - Ventilador exterior 331H, 332H, 335 o 336 - Ventilador en línea modelo HLB3, HLB6, HLB9 o HLB11 (todos con la transición) - Placa del ventilador modelo 332KR (requerida para todo los ventiladores en línea y exteriores) - Bombillas halógenas (120V, 50W, PAR 20) - Lámpara termogéna (120V, IR 175W, PAR 38) - Placa para salpicadura (opcional) - Transiciónes, conductos, codos, compuertas de tiro, remates de pared o de techo. Consultar las páginas 35 y 36 para la lista completa de los accessorios de ventilation y los números de modelo. NOTA: Si el fondo del armario está empotrado, fije los listones de madera (no incluidos) en cada lados tal como ilustrado abajo. Servirse de dos (2) listones de 2’’ de anchura para campana de 30’’ de anchura, y de cuatro (4) listones de 2’’ de anchura para campana más ancha, de largo apropiado. Vea abajo por el lugar de los listones. ANCHURA DE CAMPANA 30’’ 36’’ 42’’ 48’’ A 2’’ 2’’ 2’’ 4’’ LUGAR B N/A 41/2’’ 71/4’’ 101/4’’ C N/A 41/2’’ 81/4’’ 111/4’’ A HD0079 A B C 3. INSTALE LA PLACA PARA SALPICADURAS (OPCIONAL) La placa para salpicaduras se debe instalar antes que la campana debido a que éste cubre los tornillos de montaje de la placa para salpicaduras. Para instalar la placa de salpicadura, asegúrese de tener 18’’ entre debajo de la campana y el panel de control de la cocina o encima de la cocina. (Vea las instrucciones incluidas con la placa salpicaduras.) 4. SELECCIONE LA OPCIÓN VENTILADOR (EXTERIOR O INTERIOR) VENTILADOR INTERIOR: Siga todas las etapas subsecuentes de este manual. VENTILADOR EXTERIOR: Se refiere a las instrucciones inclidas con el ventilador exterior. Siga las etapas 6, 10, 12 y siguiente del presente manual. - 38 - 5. ELIJA LA ABERTURA (VENTILADOR INTERIOR) Rompa la abertura elegida (horizontal detrás de la campana o vertical en la placa del ventilador) de salida de aire. Ver las fotos de abajo. PRECAUCIÓN Si un ventilador P5 es instalado, quite la abertura de 10’’ de anchura (la mas pequeña). Si un ventilador P8 es instalado, quite la abertura de dimensión correspondiente a los conductos (10’’ o 14’’). tura Aber ’’ de 14 Abertura de 14’’ Abertura de 10’’ a rtur Abe 0’’ de 1 HD0076 HD0077 Rompación de la abertura horizontal detrás de la campana Rompación de la abertura vertical en la placa del ventilador 6. INSTALE LA PLACA DEL VENTILADOR (TODOS LOS VENTILADORES) VENTILADOR INTERIOR: Instalar la placa (incluye con el ventilador interior P5 y P8) al interior de la campana utilizando 4 tuercas dentelladas. Vea photo abajo. HD0042 VENTILADOR EN LÍNEA O EXTERIOR: Comprar el Modelo 332KR separadamente. Referirse a los instrucciónes incluye con el conjunto de la placa del ventilador. Instalar la placa al interior de la campana utilizando 4 tuercas dentelladas. 7. INSTALE EL DEFLECTOR DE AIRE (VENTILADOR INTERIOR) USTED DEBE también instalar el deflector de aire si usted elige la abertura vertical. Instale el desviador tal como ilustrado. NOTA: El deflector no entra completamente en la campana, fíjese que sobre sale de 1/8”. HD0003 - 39 - Inserción del desviador en la campana 8. INSTALE EL ADAPTADOR (VENTILADOR INTERIOR Utilizando los dos (2) tornillos estandar 1/2’’, instale el adaptador encima o detrás de la campana. Luego selle el adaptador con la ayuda de una cinta adhesiva a conducto. HD0005 HD0006 9. INSTALE LA CAMPANA (TODOS LOS VENTILADORES) VENTILADOR INTERIOR: Pase la alimentación eléctrica hasta el lugar de la instalación de la campana. Coloque la campana en su posición. Con la ayuda de un lápiz marque la posición de los tornillos (pequeña parte del hoyo en forma de pera) retire la campana e instale los 8 tornillos de 1/2’’ doble hilillo dejando un espacio de 1/8’’ (4 tornillos para la campana de 30’’). Saque la tapa de la caja eléctrica, inserte el alambre eléctrico. Pase el cable eléctrico en la campana y apriete el tornillo del alambre eléctrico en la entrada de la campana para mantener los cables en su posición. Coloque la campana debajo del armario (los tornillos pasan a través de la parte grande de los hoyos) y deslice la campana en su posición. Asegúrese que adaptador entre en el conducto. Atornille completamente los tornillos para que la campana se mantenga en su posición. HD0043 VENTILADOR EN LÍNEA O EXTERIOR: Pase la alimentación eléctrica hasta el lugar de la instalación de la campana. Coloque la campana en su posición. Con la ayuda de un lápiz marque la posición de los tornillos (pequeña parte del hoyo en forma de pera) retire la campana e instale los 8 tornillos de 1/2’’ doble hilillo dejando un espacio de 1/8’’ (4 tornillos para la campana de 30’’). Saque la tapa de la caja eléctrica en encima de la campana y conecte los cables (vea instruciones incluye con el ventilador exterior). Coloque la campana debajo del armario (los tornillos pasan a través de la parte grande de los hoyos) y deslice la campana en su posición. Atornille completamente los tornillos para que la campana se mantenga en su posición. - 40 - 10. CONEXIÓN ELÉCTRICA (TODOS LOS VENTILADORES) ! ADVERTENCIA Peligro de choque eléctrico. La instalación eléctrica debe ser hecha por personal calificado de acuerdo con todos los códigos aplicables y normas. Antes de efectuar el empalme, cortar la alimentación eléctrica del interruptor y cerrar con securidad para prevenir una alimentación accidental. VENTILADOR INTERIOR: Conecte los cables a la caja eléctrica utilizando los conectadores de cables. Conecte el cable NEGRO al NEGRO, el BLANCO al BLANCO y el VERDE o desnudo al el tornillo que toma de tierra. Reemplace la tapa. JAMÁS DEBE OLVIDARSE DE CONECTAR LA TOMA DE TIERRA. HD0007 1 1) Tornillo que toma de tierra VENTILADOR EN LÍNEA O EXTERIOR: Saque la tapa de la caja eléctrica de la bandeja de conexión y conecte los cables (vea instrucciones incluye con el ventilador en línea o exterior). 11. INSTALACIÓN DEL VENTILADOR (INTERIOR) El ventilador debe ser instalado a la placa del ventilador utilizando 4 tornillos de 3/8’’ para el ventilador simple y 6 tornillos de 3/8’’ para el ventilador doble. Saque la tapa del ventilador. Saque la o las rueda(s) del ventilador tirándola delicadamente (ver fotos de abajo). HD0022 HD0021 - 41 - 11. INSTALACIÓN DEL VENTILADOR (INTERIOR) (CONTINUACIÓN) Instale los tornillos en el lugar que indica la foto de abajo (ventilador simple o doble) dejando un espacio de mas o menos 1/8”. Enganche en seguida el ventilador a la placa del ventilador (pase las cabezas de los tornillos a través de la parte grandedel hoyo). En seguida resbale el ventilador en su posición (las cabezas de los tornillos a través de la parte pequeña del hoyo). Atornillar los tornillos completamente. HD0044 HD0044 Ventilador doble (P8) Ventilador simple (P5) Terminar la fijación del ventilador con 2 otros tornillos que indica las fotos de abajo (ventilador simple o doble). Reinstale la o las rueda(s) del ventilador en su posición y la tapa. HD0080 HD0081 Ventilador simple (P5) Ventilador doble (P8) DELANTE HD0023 2 1 PARA EL VENTILADOR DOBLE, ASEGURÉSE QUE LAS RUEDAS SEAN BIEN REEMPLAZADAS, LA CAMPANA NO FUNCIONARÁ NORMALMENTE SI ESTÁ AL RÉVES. Las dos ruedas del ventilador son diferentes en el caso de un ventilador doble, una debe girar en el sentido de las agujas del reloj y la otra en el sentido contrario de las agujas del reloj. Cada rueda y motor tiene una flecha y un número, usted debe juntarlos correctamente. (Ver dibujo al lado.) 1 2 HD0023 ! ADVERTENCIA Jamás conecte el cable eléctrico del ventilador con el enchufe del cable de alimentación. A Conecte el cable de la caja eléctrica (A) y el cable del ventilador (B) a los enchufes detrás del panel de control al interior de la campana. HE0003 - 42 - B 12. LUCES HALÓGENAS Esta campana utiliza bombillas halógenas de 50W (120V, 50W, PAR 20). Instale la bombilla girando en el sentido de las agujas del reloj. 13. LAMPÁRA TERMÓGENA Las bombillas termógenas necesarias son bombillas infrarrojas de 175W max. (120V, IR175W, PAR 38). Usted puede utilizar las bombillas halógenas blancas, si las tablas termogénas no son utilizadas (120V, IR175W, PAR 38). Instale la bombilla girando en el sentido de las agujas del reloj. 14. INSTALE LOS FILTROS Es recomendable de instalar los filtros de lado en primer lugar y de terminar con el o los filtro del centro. INSTALACIÓN DE LOS FILTROS 1. Deslice la parte superior de los filtros en la campana. 2. Giro la parte inferior hacia el interior de la campana. 3. Instale los filtros debajo del atadero y tire. 4. Cuando este tirando sobre los filtros, deslice debajo de la pieza del retenido interior. Los filtros de zig zag son disponibles en opción (ver la hoja de instalación que se encuerta incluida con los filtros a zig zag). HD0009 HD0010 1 1) Atadero 15. MANTENIMIENTO Filtros y la(s) rueda(s) del ventilador. Los filtros, canal y la(s) rueda(s) del ventilador deben ser frecuentemente limpiadas. Use agua tibia y una solución de detergente. Los filtros y la(s) rueda(s) del ventilador se pueden lavar en el lavaplatos. - 43 - 15. MANTENIMIENTO (CONTINUACIÓN) Limpieza de la campana Acero inoxidable: como mantener una apariencia brillante. Lo que debe hacer: - Lavar regularmente la superficie con un trapo o un paño empapado de agua tibia y de jabón suave o detergente a vajilla. - Siempre limpie en el sentido de las líneas originales de pulimento. - Siempre enjuague bien con agua limpia (2 a 3 veces) después de haber limpiado seque completamente la superficie. - Usted puede utilizar un limpiador doméstico hecho especialmente para el acero inoxidable. Lo que no debe hacer: - No utilice ninguna lana de acero o de acero inoxidable o todo otro raspador para quitar la suciedad tenaz. - No utilice ningún limpiador en polvo abrasivo o riguroso. - No deje la suciedad acumularse. - No deje el polvo de yeso o todo otro residuo de construcción que caiga en la campana, cúbrala durante el trabajo para asegurarse que en ningún caso el polvo se pegue a la superficie del acero. A evitar cuando elige un detergente: - Todos los productos de limpieza que contienen agentes de blanqueo; van a deteriorar el acero inoxidable. - Todos los productos que contienen cloruro, fluoruro, yoduro o bromuro; estos deterioran rápidamente las superficies. - Todos los productos combustible utilizados para la limpieza: acetona, alcohol, éter, benzol, etc...; son extremamente explosivos y no deben ser utilizados cerca de una cocina. Superficies pintadas: Limpie con agua caliente agregue solamente un detergente suave. Si hay decoloración, utilice una buena cera a pintura como una cera para auto. (NO UTILICE un limpiador casero rugoroso o un limpiador a porcelana.) 16. FUNCIONAMIENTO Siempre hacer funcionar la campana antes de comenzar a cocinar a fin de establecer una circulación de aire en la cocina. Deje igualmente funcionar la campana algunos minutos después de que pare de cocinar a fin de limpiar el aire. Esto ayuda a concervar la cocina mas limpia y un aire puro. 1 1 HD0013 2 3 4 1) Lámparas termogénas 2) Luces halógenas 3) Encender/apagar ventilador 4) Control de velocidad del ventilador VENTILADOR El ventilador funciona con la ayuda de dos controles. Utilice el interruptor encender/apagar tiene una luz roja para encender y apagar el ventilador. Cuando está en tensión, el ventilador funciona a la velocidad utilizada la última vez. Utilice el control de velocidad del ventilador girando en el sentido de las agujas del reloj para disminuir la velocidad y en el sentido contrario de las agujas del reloj para aumentar la velocidad. LÁMPARAS HALÓGENAS Los dos interruptores de encender/apagar controlan las luces halógenas. El interruptor a báscula antes, controla la luz del centro (para las campanas 42’’ y 48’’). El interruptor detrás controla las luces de cada lado. (Cada interruptor controla la luz para las campanas de 30’’ y 36’’.) Encienda una o dos luces según su necesidad. Utilice las bombillas de halógenas PAR 20, 50W. - 44 - 16. FUNCIONAMIENTO (CONTINUACIÓN) ! ADVERTENCIA Jamás dejar materias inflamables debajo de las lámparas termogéna. LÁMPARAS TERMOGÉNA (INFRARROJAS) Cada lámpara es controlada independientemente con su propio interruptor. Utilice las bombillas infrarrojas (120V, IR175W, PAR38) o las bombillas halógenas (120V, 90W, PAR38) si las tablas sirven para recalentar los alimentos no son utilizadas. HEAT SENTRY Su campana esta equipada con Heat Sentry. Este termostato tiene un mecanismo que se encenderá o acelerará el ventilador si se detecta un calor excesivo encima de la cocina. 1.-Si el ventilador esta apagado - el se prenderá a una velocidad máxima. 2.-Si el ventilador esta encendido a una velocidad mínima - el se prenderá a una velocidad máxima. ! ADVERTENCIA HEAT SENTRY puede comenzar a funcionar al igual si la campana esta parada. En este caso, es imposible parar el ventilador con los interruptores. Si usted para la campana, halago a partir del panel eléctrico principal. Cuando la temperatura disminuye a un nivel normal, el ventilador vuelve a la función de origen. GARANTÍA BROAN-NUTONE LLC GARANTÍA LIMITADA POR UN AÑO Broan-NuTone LLC garantiza al consumidor comprador original de sus productos que dichos productos carecerán de defectos en materiales o en mano de obra por un período de un año a partir de la fecha original de compra. NO EXISTEN OTRAS GARANTÍAS, EXPRESAS O IMPLÍCITAS, INCLUYENDO, PERO NO LIMITADAS A, GARANTÍAS IMPLÍCITAS DE COMERCIALIZACIÓN O ACTITUD PARA UN PROPOSITO PARTICULAR. Durante el período de un año, y a su propio criterio, Broan-NuTone LLC reparará o reemplazará, sin costo todo producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso. Esta garantía no cubre (a) mantenimiento y servicios normales o (b) cualquier productos o piezas que hayan sido mantenidas o reparadas en inapropiadamente (por otras compañías que sea Broan-NuTone LLC), instalación defectuosa, o instalación no conforme a las instrucciones de instalación recomendadas. La duración de cualquier garantía implícita se limita a un periodo de un año como se especifica en la garantía expresa. Algunos estados o provincias no permiten limitaciones en cuanto al tiempo de expiración de una garantía implícita, por lo que la limitación antes mencionada puede no aplicarse a usted. LA OBLIGACIÓN DE BROAN-NUTONE LLC DE REPARAR O REEMPLAZAR, SIGUIENDO EL CRITERIO DE BROAN-NUTONE LLC DEBERÁ SER EL UNICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANTÍA. BROAN-NUTONE LLC NO SERÁ RESPONSABLE POR DAÑOS ACCIDENTALES, CONSIGUIENTES, O POR DAÑOS ESPÉCIALES SURGIDOS O EN CONEXIÓN CON EL USO O EL RENDIMIENTO DEL PRODUCTO. Algunos estados o provincias no permiten la exclusión o limitación de daños accidentales o consiguientes, por lo que la limitación antes mencionada puede no aplicarse a usted. Esta garantía le proporciona derechos legales específicos, y usted puede también tener otros derechos, los cuales varían de estado a estado o de provincia a provincia. Esta garantía reemplaza todas las garantías anteriores. Para calificar en el servicio de garantía, usted debe (a) notificar a Broan-NuTone LLC al uno domicilio o telephono que menciona abajo, (b) dar el número del modelo y la identificación de la pieza y (c) describir la naturaleza de cualquier defecto en el producto o pieza. En el momento de solicitar servicio cubierto por la garantía, usted debe presentar evidencia de la fecha original de la compra. Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626) - 45 - REPUESTOS Serie 64000 1 2 18 2 20 17 17 19 3 7 12 6 5 13 4 15 16 14 17 17 17 8 2 9 10 11 2 8 HL0002 REF. N.° 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 N.° PIEZA V06750 V02264 V02773 V02772 V03435 V03436 V03501 V03507 V03502 V03503 V03504 V03505 V03517 V03518 V03519 V03520 V00673 V02512 V01869 V01582 V00606 V03509 V03510 V13216 V13217 V13218 V13219 V03686 V02544 V03598 V03515 V13278 DESCRIPCIÓN LOGOTIPO BROAN ELITE CASQUETE CONNECTADOR MACHO CONNECTADOR HEMBRA TERMOSTATO SOPORTE POR TERMOSTATO CONTROL DE VELOCIDAD INTERRUPTOR SIMPLE SPST PARA LAMPARA TERMÓGENA INTERRUPTOR DOBLE SPST PARA LAMPARA HALÓGENA INTERRUPTOR SIMPLE ILLUMINADO SPST POR VENTILADOR BOTÓN CONTROL DE VELOCIDAD TERMINAL DE CONEXIÓN CABLE DE ALIMENTACIÓN 10" CABLE LÁMPÁRA TERMOGÉNA 10" CABLE CONTROL 10" CABLE INTERRUPTOR ILUMINADO 10" TUERCA DENTELLADA N.° 8-32 TORNILLO N.° 8-32 x 1/2" TORNILLO MECÁNICO N.° 6-32 x 1/4" TUERCA DENTELLADA N.° 6-32 TORNILLO N.° 8-3/8" T/B CABEZA N.° 8 FILTRO RANGEMASTER 8,930” x 9,800” FILTRO RANGEMASTER 11,930” x 9,800” CANAL 30" CANAL 36" CANAL 42" CANAL 48" GRAPA FILTROS BOMBILLA HALOGENA PAR 20 50 W LAMPARA TERMOGÉNA MANUAL DE INSTALACIÓN BOLSA DE INSTALACIÓN ((4) tuercas a brida N.° 10-32, (1) alambre eléctrico LP16-AP, (2) conectador de cable N.° 74B, (8) tornillo doble hillilo 6-12 x 0.5, (6) tornillo N.° 8 x 3/8”, (2) tornillo N.° 6 x 1/2") - 46 - CTD (largo de la campana) 30” 36” 42” 48” 1 1 1 1 4 4 5 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 7 7 8 8 2 2 1 3 2 4 1 1 1 1 3 3 4 4 2 2 3 3 2 2 2 2 1 1 1 1 1 1 1 1 REPUESTOS PLACA Y VENTILADOR SIMPLE (Modelo P5) 1 20 21 2 23 22 19 3 4 17 5 6 18 16 15 14 13 6 7 8 12 9 11 10 HL0021 REF. N.° 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 N.° PIEZA V13296 V03500 V12997 V03577 V02160 V01869 V01857 V01582 V14973 V01810 V03400 V01766 V00871 V02001 V01831 V11705 V11614 V01927 V03495 V03494 V13230 V03496 V00660 V05520 V00613 DESCRIPCIÓN ADAPTADOR & COMPUERTA 3 /4’’ x 10’’ DEFLECTOR DE AIRE MONTAJE DE PLACA DE VENTILADOR SIMPLE ESPUMA 1/2” x 1/2” x 12” CONDENSADOR 15MFD TORNILLO MECÁNICO N.° 6-32 x 1/4” CUBRE-CABLE TUERCA DENTELLADA N.° 6-32 MONTAJE DE VENTILADOR SIMPLE ANILLO RUEDA RUEDA CAMPANA 7,094” x 3,375” CW MOTOR 165W CW ARANDELA 3/16” DI x 3/4’’ DE OJETE MOTOR G-431-1 ABRAZADERA 8” SOPORTE MOTOR CABLE N.° 18 TEW MARRÓN x 10” TORNILLO METRICO M4 x 6MM (TIPO PAN) QDRX APAGO DE TRACCIÓN CABLE VENTILADOR CABLE ALIMENTACIÓN VENTILADOR 36” PUERTA CONEXIÓN ELÉCTRICA CABLE ALIMENTACIÓN 120 VOLTIOS APAGO DE TRACCIÓN CABLE ALIMENTACIÓN TORNILLO N.° 8 x 3/8”, T/B, CABEZA N.° 8 TORNILLO N.° 10-32 x 3/8” , TF, VERDE 1 - 47 - CTD 1 1 1 1 1 4 1 1 1 2 1 1 3 3 2 1 1 4 1 1 1 1 1 2 2 REPUESTOS 2 PLACA Y VENTILADOR DOBLE (Modelo P8) 1 25 3 4 24 23 22 21 5 19 18 17 16 15 14 6 7 8 11 20 9 13 10 12 REF. N.° 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 N.° PIEZA V14971 V13296 V03500 V14975 V03577 V01582 V02160 V01857 V01766 V03400 V14974 V01810 V03399 V03457 V00871 V01831 V11705 V11614 V02001 V01927 V03495 V03494 V14960 V00660 V03496 V00606 V00613 DESCRIPCIÓN ADAPTADOR & COMPUERTA 3 /4’’ x 14’’ ADAPTADOR & COMPUERTA 31/4’’ x 10’’ DEFLECTOR DE AIRE MONTAJE DE PLACA DE VENTILADOR DOBLE ESPUMA 1/2” x 1/2” x 12” TUERCA DENTELLADA N.O 6-32 CONDENSADOR 15MFD CUBRE-CABLE MOTOR 165W CW RUEDA CAMPANA 7,094” x 3,375” CW MONTAJE DE VENTILADOR DOBLE ANILLO RUEDA RUEDA CAMPANA 7,094” x 3,375” CCW MOTOR 165W CCW ARANDELA 3/16” DI x 3/4” DE ABRAZADERA 8” SOPORTE MOTOR CABLE N.° 18 TEW MARRÓN x 10” OJETE MOTOR G-431-1 TORNILLO MÉTRICO M4 X 6MM (TIPO PAN) QDRX APAGO DE TRACCIÓN CABLE VENTILADOR CABLE ALIMENTACIÓN VENTILADOR 36” PUERTA CONEXIÓN ELÉCTRICA APAGO DE TRACCIÓN CABLE ALIMENTACIÓN CABLE ALIMENTACIÓN 120 VOLTIOS TORNILLO N.° 8 x 3/8”, T/B, CABEZA N.° 8 TORNILLO N.° 10-32 x 3/8”, TF, VERDE 1 CTD. 1 1 1 1 1 1 2 2 1 1 1 2 1 1 6 4 2 2 6 8 1 1 1 1 1 4 2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

NuTone 644201 Installation Instructions Manual

Categoría
Campanas de cocina
Tipo
Installation Instructions Manual
Este manual también es adecuado para

en otros idiomas