Transcripción de documentos
DIGITAL MIXING ENGINE
Owner’s Manual
EN
Explanation of Graphical Symbols
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE
COVER (OR BACK). NO USER-SERVICEABLE
PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol
within an equilateral triangle is intended to
alert the user to the presence of uninsulated
“dangerous voltage” within the product’s
enclosure that may be of sufficient
magnitude to constitute a risk of electric
shock to persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the product.
The above warning is located on the top of the unit.
IMPORTANT SAFETY INSTRUCTIONS
1
Read these instructions.
2
Keep these instructions.
3
Heed all warnings.
4
Follow all instructions.
5
Do not use this apparatus near water.
6
Clean only with dry cloth.
7
Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions.
8
Do not install near any heat sources such as
radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9
Do not defeat the safety purpose of the polarized
or grounding-type plug. A polarized plug has two
blades with one wider than the other. A grounding
type plug has two blades and a third grounding
prong. The wide blade or the third prong are
provided for your safety. If the provided plug does
not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10 Protect the power cord from being walked on or
pinched particularly at plugs, convenience
receptacles, and the point where they exit from the
apparatus.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
11 Only use attachments/accessories specified by
the manufacturer.
12 Use only with the cart, stand,
tripod, bracket, or table
specified by the manufacturer,
or sold with the apparatus.
When a cart is used, use
caution when moving the cart/
apparatus combination to avoid
injury from tip-over.
13 Unplug this apparatus during lightning storms or
when unused for long periods of time.
14 Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord
or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.
FCC INFORMATION (U.S.A.)
1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!
This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not
expressly approved by Yamaha may void your authority, granted
by the FCC, to use the product.
2. IMPORTANT: When connecting this product to accessories and/
or another product use only high quality shielded cables. Cable/s
supplied with this product MUST be used. Follow all installation
instructions. Failure to follow instructions could void your FCC
authorization to use this product in the USA.
3. NOTE: This product has been tested and found to comply with the
requirements listed in FCC Regulations, Part 15 for Class “B” digital devices. Compliance with these requirements provides a reasonable level of assurance that your use of this product in a
residential environment will not result in harmful interference with
other electronic devices. This equipment generates/uses radio frequencies and, if not installed and used according to the instructions found in the users manual, may cause interference harmful to
the operation of other electronic devices. Compliance with FCC
regulations does not guarantee that interference will not occur in all
installations. If this product is found to be the source of interference, which can be determined by turning the unit “OFF” and
“ON”, please try to eliminate the problem by using one of the following measures:
Relocate either this product or the device that is being affected by
the interference.
Utilize power outlets that are on different branch (circuit breaker or
fuse) circuits or install AC line filter/s.
In the case of radio or TV interference, relocate/reorient the
antenna. If the antenna lead-in is 300 ohm ribbon lead, change the
lead-in to co-axial type cable.
If these corrective measures do not produce satisfactory results,
please contact the local retailer authorized to distribute this type of
product. If you can not locate the appropriate retailer, please contact Yamaha Corporation of America, Electronic Service Division,
6600 Orangethorpe Ave, Buena Park, CA90620
The above statements apply ONLY to those products distributed
by Yamaha Corporation of America or its subsidiaries.
* This applies only to products distributed by YAMAHA CORPORATION OF AMERICA.
ADVARSEL!
IMPORTANT NOTICE FOR THE UNITED KINGDOM
Connecting the Plug and Cord
WARNING: THIS APPARATUS MUST BE EARTHED
IMPORTANT. The wires in this mains lead are coloured in accordance with the following code:
GREEN-AND-YELLOW : EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
As the colours of the wires in the mains lead of this apparatus may
not correspond with the coloured markings identifying the terminals
in your plug proceed as follows:
The wire which is coloured GREEN-and-YELLOW must be connected
to the terminal in the plug which is marked by the letter E or by the
safety earth symbol
or colored GREEN or GREEN-and-YELLOW.
The wire which is coloured BLUE must be connected to the terminal
which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED.
• This applies only to products distributed by Yamaha-Kemble Music (U.K.) Ltd.
(class B)
(3 wires)
Lithiumbatteri—Eksplosionsfare ved fejlagtig håndtering. Udskiftning
må kun ske med batteri af samme fabrikat og type. Levér det brugte
batteri tilbage til leverandoren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp
eller en ekvivalent typ som rekommenderas av apparattillverkaren.
Kassera använt batteri enligt fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo
ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty
paristo valmistajan ohjeiden mukaisesti.
(lithium caution)
This product contains a battery that contains perchlorate material.
Perchlorate Material—special handling may apply,
See www.dtsc.ca.gov/hazardouswaste/perchlorate.
• This applies only to products distributed by YAMAHA CORPORATION OF AMERICA.
(Perchlorate)
COMPLIANCE INFORMATION STATEMENT
(DECLARATION OF CONFORMITY PROCEDURE)
NEDERLAND / THE NETHERLANDS
• Dit apparaat bevat een lithium batterij voor geheugen back-up.
• This apparatus contains a lithium battery for memory back-up.
• Raadpleeg uw leverancier over de verwijdering van de batterij op
het moment dat u het apparaat ann het einde van de levensduur of
gelieve dan contact op te nemen met de vertegenwoordiging van
Yamaha in uw land.
• For the removal of the battery at the moment of the disposal at the
end of life please consult your retailer or Yamaha representative
office in your country.
• Gooi de batterij niet weg, maar lever hem in als KCA.
• Do not throw away the battery. Instead, hand it in as small chemical
waste.
(lithium disposal)
In Finland: Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.
In Norway: Apparatet må tilkoples jordet stikkontakt.
In Sweden: Apparaten skall anslutas till jordat uttag.
(class I hokuo)
Responsible Party : Yamaha Corporation of America
Address : 6600 Orangethorpe Ave., Buena Park,
Calif. 90620
Telephone : 714-522-9011
Type of Equipment : Digital Mixing Engine
Model Name : DME64N / DME24N
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received including interference that may cause undesired operation.
See user manual instructions if interference to radio reception is suspected.
* This applies only to products distributed by
YAMAHA CORPORATION OF AMERICA.
(FCC DoC)
PRECAUTIONS
PLEASE READ CAREFULLY BEFORE PROCEEDING
* Please keep this manual in a safe place for future reference.
WARNING
Always follow the basic precautions listed below to avoid the possibility of serious injury or even death from
electrical shock, short-circuiting, damages, fire or other hazards. These precautions include, but are not limited
to, the following:
Power supply/Power cord
Water warning
• Only use the voltage specified as correct for the device. The required
voltage is printed on the name plate of the device.
• Use only the supplied power cord/plug.
• Do not place the power cord near heat sources such as heaters or
radiators, and do not excessively bend or otherwise damage the cord,
place heavy objects on it, or place it in a position where anyone could walk
on, trip over, or roll anything over it.
• Do not expose the device to rain, use it near water or in damp or wet
conditions, or place on it any containers (such as vases, bottles or
glasses) containing liquids which might spill into any openings.
If any liquid such as water seeps into the device, turn off the power
immediately and unplug the power cord from the AC outlet. Then have the
device inspected by qualified Yamaha service personnel.
• Never insert or remove an electric plug with wet hands.
• Be sure to connect to an appropriate outlet with a protective grounding
connection. Improper grounding can result in electrical shock.
Fire warning
• Check the electric plug periodically and remove any dirt or dust which may
have accumulated on it.
• Do not put burning items, such as candles, on the unit. A burning item
may fall over and cause a fire.
Do not open
If you notice any abnormality
• The device contains no user-serviceable parts. Do not open the device or
attempt to disassemble the internal parts or modify them in any way. If it
should appear to be malfunctioning, discontinue use immediately and
have it inspected by qualified Yamaha service personnel.
• When one of the following problems occur, immediately turn off the power
switch and disconnect the electric plug from the outlet. Then have the
device inspected by Yamaha service personnel.
• The power cord or plug becomes frayed or damaged.
• It emits unusual smells or smoke.
• Some object has been dropped into the instrument.
• There is a sudden loss of sound during use of the device.
• If this device should be dropped or damaged, immediately turn off the
power switch, disconnect the electric plug from the outlet, and have the
device inspected by qualified Yamaha service personnel.
CAUTION
Always follow the basic precautions listed below to avoid the possibility of physical injury to you or others, or
damage to the device or other property. These precautions include, but are not limited to, the following:
Power supply/Power cord
• Remove the electric plug from the outlet when the device is not to be used
for extended periods of time, or during electrical storms.
• Do not place the device in an unstable position where it might accidentally
fall over.
• When removing the electric plug from the device or an outlet, always hold
the plug itself and not the cord. Pulling by the cord can damage it.
• Do not block the vents. This device has ventilation holes at the front and
rear to prevent the internal temperature from rising too high. In particular,
do not place the device on its side or upside down, or place it in any
poorly-ventilated location, such as a bookcase or closet.
Location
• Do not place the device in a location where it may come into contact with
corrosive gases or salt air. Doing so may result in malfunction.
• Before moving the device, remove all connected cables.
• When setting up the device, make sure that the AC outlet you are using is
easily accessible. If some trouble or malfunction occurs, immediately turn
off the power switch and disconnect the plug from the outlet. Even when
the power switch is turned off, electricity is still flowing to the product at
the minimum level. When you are not using the product for a long time,
make sure to unplug the power cord from the wall AC outlet.
4
DME64N/DME24N Owner’s Manual
(5)-1
Connections
• Before connecting the device to other devices, turn off the power for all
devices. Before turning the power on or off for all devices, set all volume
levels to minimum.
1/2
Maintenance
Backup battery
• Remove the power plug from the AC outlet when cleaning the device.
Handling caution
• Do not insert your fingers or hand in any gaps or openings on the device
(vents, ports, etc.).
• Avoid inserting or dropping foreign objects (paper, plastic, metal, etc.) into
any gaps or openings on the device (vents, ports, etc.) If this happens,
turn off the power immediately and unplug the power cord from the AC
outlet. Then have the device inspected by qualified Yamaha service
personnel.
• Do not use the device or headphones for a long period of time at a high or
uncomfortable volume level, since this can cause permanent hearing loss.
If you experience any hearing loss or ringing in the ears, consult a
physician.
• Do not rest your weight on the device or place heavy objects on it, and
avoid use excessive force on the buttons, switches or connectors.
This device has a built-in backup battery that maintains data in
internal memory even when the device’s power is switched off. The
backup battery will eventually become depleted, however, and when
that happens the contents of the internal memory will be lost.* To
prevent loss of data be sure to replace the backup battery before it
becomes fully depleted. When the remaining capacity of the backup
battery becomes so low that it needs to be replaced a “Low Battery”
or “No Battery” message will appear on the display during operation
or when the device is powered on. If either of these messages
appears do not turn off the power and immediately transfer any data
you want to save to a computer or other external storage device,
then have qualified Yamaha service personnel replace the backup
battery. The average life of the internal backup battery is
approximately 5 years, depending on operating conditions.
* Data items maintained in the internal memory by the backup
battery are as follows:
• Current scene parameters and number.
• Device parameters (SLOT, HA, UTILITY, Master Mute/Level, etc.).
• Event log.
Data items other than those described above are stored in memory
that does not require backup power, and will be retained even if the
backup battery fails.
Yamaha cannot be held responsible for damage caused by improper use or modifications to the device, or data that is lost or destroyed.
Do not turn the [POWER] switch on and off repeatedly and rapidly. Be sure to wait six seconds or more between turning the
power to the unit off and then on.
Always turn the power off when the device is not in use.
The performance of components with moving contacts, such as switches, volume controls, and connectors, deteriorates over
time. Consult qualified Yamaha service personnel about replacing defective components.
NOTICE
To avoid the possibility of damage to the product, data or other property, follow the notices below.
Handling and Maintenance
• Do not use the device in the vicinity of a TV, radio, stereo equipment,
mobile phone, or other electric devices. Otherwise, the device, TV, or radio
may generate noise.
• Condensation can occur in the device due to rapid, drastic changes in
ambient temperature-when the device is moved from one location to
another, or air conditioning is turned on or off, for example. Using the
device while condensation is present can cause damage. If there is reason
to believe that condensation might have occurred, leave the device for
several hours without turning on the power until the condensation has
completely dried out.
• Do not expose the device to excessive dust or vibrations, or extreme cold
or heat (such as in direct sunlight, near a heater, or in a car during the day)
to prevent the possibility of panel disfiguration or damage to the internal
components.
• Avoid setting all equalizer controls and faders to their maximum.
Depending on the condition of the connected devices, doing so may cause
feedback and may damage the speakers.
Information
About this manual
• The illustrations in this document are for instructional purposes, and may
appear somewhat different from the actual equipment.
• The bitmap fonts used in this device have been provided by and are the
property of Ricoh Co., Ltd.
• Ethernet is a trademark of Xerox Corporation.
• All other trademarks are the property of their respective holders and are
hereby acknowledged.
• CobraNet and Peak Audio are trademarks of Cirrus Logic, Inc.
(5)-1
2/2
DME64N/DME24N Owner’s Manual
5
Foreword
Foreword
Thank you for choosing a Yamaha DME64N/24N Digital Mixing Engine.
Using the supplied DME Designer software, the DME64N and DME24N can be easily
configured to handle a wide range of audio processing applications – institutional audio
installations, sub-mixing, speaker system control, matrix and routing, multi-effect processing,
and much more.
In order to take full advantage of the features and performance provided by the DME64N/24N,
we urge you to read this owner’s manual thoroughly before use, and keep it in a safe place for
future reference.
The Yamaha Pro Audio web site is at: http://www.yamahaproaudio.com/
6
DME64N/DME24N Owner’s Manual
Contents
Foreword
8
Accessories (Please make sure the following
items are included in the package.). . . . . . . . . . . 8
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
About the Product Names . . . . . . . . . . . . . . . . . . 8
About the Firmware Version. . . . . . . . . . . . . . . . . 8
Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Connecting the AC power cord . . . . . . . . . . . . . . . . . . . . . .8
Turning the power on and off . . . . . . . . . . . . . . . . . . . . . . .8
Introduction to the DME64N/24N
9
Differences between DME64N/24N . . . . . . . . . . . 9
DME64N/24N Features . . . . . . . . . . . . . . . . . . . . . 9
Audio System Network . . . . . . . . . . . . . . . . . . . . . 9
Glossary for the DME64N/24N . . . . . . . . . . . . . . . 9
Signal Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
System Examples . . . . . . . . . . . . . . . . . . . . . . . . 12
About DME Designer. . . . . . . . . . . . . . . . . . . . . . 13
The Controls and Connectors
14
Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Setup
18
Setup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . 18
I/O Card Installation. . . . . . . . . . . . . . . . . . . . . . . 20
Compatible I/O Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
I/O Card Installation Procedure. . . . . . . . . . . . . . . . . . . . .21
Connecting to a Computer
22
USB Connection . . . . . . . . . . . . . . . . . . . . . . . . . 22
Ethernet Connection ([NETWORK] Connector) 23
Audio I/O Connection
26
Analog Audio Connection ([IN] and [OUT] Connectors)
(DME24N only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
I/O Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Connecting to an External Device
Panel Operation and Displays
34
Basic Operation . . . . . . . . . . . . . . . . . . . . . . . . . 34
Main Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Parameter Edit Displays. . . . . . . . . . . . . . . . . . . 36
Editing User Defined Button . . . . . . . . . . . . . . . . . . . . . .
Mute Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scene Recall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scene Store . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spectrum Display . . . . . . . . . . . . . . . . . . . . . . . .
Level Meter Display . . . . . . . . . . . . . . . . . . . . . .
Initializing the DME64N/DME24N. . . . . . . . . . . .
Utility Displays . . . . . . . . . . . . . . . . . . . . . . . . . .
41
42
42
43
Items accessible via the Utility display. . . . . . . . . . . . . . .
Utility Display Operation . . . . . . . . . . . . . . . . . . . . . . . . .
Info Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Network Settings (Net) Page . . . . . . . . . . . . . . . . . . . . . .
Display Setup (Disp) Page. . . . . . . . . . . . . . . . . . . . . . . .
Security Setup (Lock) Page . . . . . . . . . . . . . . . . . . . . . . .
Miscellaneous Setup (Misc) Page . . . . . . . . . . . . . . . . . .
Remote Control Setup (Remote) Page . . . . . . . . . . . . . .
MIDI Setup (MIDI) Page . . . . . . . . . . . . . . . . . . . . . . . . .
Word Clock Setup (WCLK) Page. . . . . . . . . . . . . . . . . . .
Slot Information (Slot) Page. . . . . . . . . . . . . . . . . . . . . . .
GPI Setup (GPI) Page . . . . . . . . . . . . . . . . . . . . . . . . . . .
Head Amplifier Setup (HA) Page . . . . . . . . . . . . . . . . . . .
Cascade Setup (CASCAD) Page . . . . . . . . . . . . . . . . . .
Check Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
References
38
39
39
39
40
40
43
45
45
46
46
47
48
48
49
50
51
51
52
53
54
55
Introduction to
the DME64N/24N
The Controls
and Connectors
Setup
Connecting to
a Computer
Audio I/O
Connection
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
ICP1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
CP4SW, CP4SF, and CP1SF . . . . . . . . . . . . . . . . . . . . . 55
Error Messages. . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input/Output Characteristics . . . . . . . . . . . . . . .
Control I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connector Pin Assign . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MIDI Data Format . . . . . . . . . . . . . . . . . . . . . . . .
MIDI Implementation Chart . . . . . . . . . . . . . . . .
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
56
59
60
61
62
63
65
66
70
71
28
Remote Connection ([REMOTE] Connector) . . 28
Foreword
Connecting to an
External Device
Panel Operation
and Displays
References
Index
73
Controlling external head amplifiers from the DME64N/24N 28
Controlling a DME24N’s internal head amps from a digital
mixer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Controlling the DME64N/24N from an external device . . .29
Network Connection ([NETWORK] Connectors) 30
MIDI Connection ([MIDI] Connectors) . . . . . . . . 30
Cascade Connection ([Cascade] Connectors)
(DME64N only) . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
WORD CLOCK Connection ([WORD CLOCK]
Connectors) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
GPI Connection ([GPI] Connectors). . . . . . . . . . 33
DME64N/DME24N Owner’s Manual
7
Accessories (Please make sure the following items are included in the package.)
Foreword
Thank you for choosing a Yamaha DME64N/24N Digital Mixing Engine.
In order to take full advantage of the features and performance provided by the DME64N/24N, we urge you to read this
owner’s manual thoroughly before connecting or using the unit. Keep this manual in a safe place for future reference.
Foreword
Accessories (Please make
sure the following items are
included in the package.)
•
•
•
•
•
•
DME64N/DM24N Owner’s Manual
(This document)
AC power cord
AC plug clamp
Euroblock plug (16P) x 2
Euroblock plug (8P) x 4 (DME64N only)
Euroblock plug (3P) x 16 (DME24N only)
Options
Preparation
Connecting the AC power cord
CAUTION
First plug the female-connector end of the AC cord into
the [AC IN] socket on the rear panel of the DME64N/
24N, then plug the male plug into an appropriate AC
mains outlet.
Be sure to use the voltage specified for the device.
Turning the power on and off
Control Panels
•
•
•
•
ICP1 Intelligent Control Panel
CP4SW Control Panel
CP4SF Control Panel
CP1SF Control Panel
CAUTION
NOTE
For more information on your Control Panel, refer to the
owner’s manual that came with the Control Panel, as
well as the DME Designer Owner’s Manual.
About the Product Names
Be sure to turn all devices OFF before
connecting AC mains power.
To prevent the initial power-on surge from
generating a large noise spike or damaging
your speaker system, turn the devices on in
the following order: audio sources, mixer
(such as M7CL or PM5D), DME64N/24N, and
finally power amplifiers.
Reverse this order when turning power off.
1. Press the [POWER] switch to turn on the
power to the DME64N/24N.
2. Press the [POWER] switch again to turn off
the power.
NOTE
In this manual, models DME64N, DME24N, DME8i-C,
DME8o-C, DME4io-C, DME8i-ES, DME8o-ES and
DME4io-ES are categorized as DME series, and models
DME8i-C, DME8o-C, DME4io-C, DME8i-ES, DME8o-ES
and DME4io-ES are all called the “DME Satellite”.
About the Firmware Version
The DME64N/24N remembers scene settings when you
turn off the power.
When you turn on the power to the DME64N/24N, it will
start up with the same scene settings.
You can set up the DME64N/24N so that at the startup it
will recall the scene selected before you turned off the
power to the device. (page 48)
You can download the latest firmware from the following
Yamaha website.
http://www.yamahaproaudio.com/downloads/
CAUTION
CAUTION
8
DME64N/DME24N Owner’s Manual
Do NOT turn off the power to the DME64N/24N
while it is receiving data from DME Designer
or while it is being manipulated from an
external device. Otherwise, a malfunction may
occur.
Even when the power switch is turned off,
electricity is still flowing to the product all the
minimum level. When you are not using the
product for a long time, make sure to unplug
the power cord from the wall AC outlet.
Differences between DME64N/24N
Introduction to the DME64N/24N
Differences between DME64N/24N
The DME64N has four I/O card slots, while the DME24N has one I/O card slot and eight channels of builtin analog audio I/O.
A single I/O card can handle up to 16 channels of audio I/O, so the DME64N can handle a maximum of 64
audio I/O channels. The DME24N can handle up to 24 audio I/O channels.
The DME64N has approximately double the DSP processing power of the DME24N.
DME64N/24N Features
Introduction to the DME64N/24N
In addition to basic mixing and matrix output functions, the DME64N/24N includes a equalizers, compressors, delay, etc. – that can be patched together via DME Designer to configure just about any audio system
you need.
Audio System Network
Multiple DME series units that are interconnected in a network via Ethernet function as a single audio system.
In a DME audio system, a group of the same models that can be operated in sync is called a “device group;”
audio processing divisions that accommodate multiple device groups are called “zones;” and the entire
area serviced by the acoustic system is called an “area.”
Each device group always includes one DME series unit that functions as the “group master” and controls
all other DME series units in the same device group.
If a computer is connected to the network, you can use the computer to control an entire device group via
the group master.
Glossary for the DME64N/24N
This section explains terminology specific to the DME64N/24N.
Components and parameters
The individual audio processing modules (equalizers, compressors, etc.) are called “components.”
External head amplifier control modules are also available as components.
Changing the parameters of components enables control over the operation of the components.
Configuration
A “configuration” is a complete set of components for constructing an audio system.
Each configuration determines the audio function(s) of the corresponding DME64N/24N unit.
All parameter sets included with each component in a configuration are called “preset parameters.”
One DME64N/24N unit has a number of configurations, and a configuration has a number of preset parameters.
User Defined buttons
Assigning parameters to be User Defined Buttons enables you to control the device from the ICP1 and the
DME64N/DME24N.
Refer to the DME Designer Owner’s Manual for details.
DME64N/DME24N Owner’s Manual
9
Glossary for the DME64N/24N
Scene
A combination of all configuration and preset parameters is called a “scene.”
Scenes can be recalled from an ICP1, GPI device, other external controllers, DME64N/DME24N, or computer.
Up to 999 scenes can be stored for each device group.
Scene structure
Scene
Preset
Parameter
Configuration
Matrix Mixer
Scene 1
Ex.: Gate
• Attack
• Decay
• Range
• Threshold
• Key in
• Hold
Scene 2
16 x 8
Scene 999
Component
Introduction to the DME64N/24N
Scene change
First Act
Band Set
Play Set
Stage
1
EXT.
CLOCK
NETWORK
96kHz
MID
88.2kHz
MASTER
48kHz
2
3
4
2
3
4
5
6
7
8
5
6
7
8
Dark Change
Band
Set
Play Set
Play
Set
1
Band Set
Stage
Stage
1
PEAK
IN
SIGNAL
Second Act
EXT.
CLOCK
NETWORK
96kHz
MID
88.2kHz
MASTER
48kHz
44.1kHz
2
3
4
2
3
4
5
6
7
8
5
6
7
8
PEAK
IN
SIGNAL
1
44.1kHz
PEAK
PEAK
SCENE NUMBER
SIGNAL
SCENE NUMBER
OUT
SIGNAL
Scene 1
10
DME64N/DME24N Owner’s Manual
Scene Recall
OUT
Scene 2
Signal Types
Signal Types
DME64N/24N audio system signals can be broadly categorized as follows.
1 Audio
The DME64N/24N will be required to send and receive audio signals to and from other DME series units as
well as other audio equipment.
Audio signal transmission and reception will occur primarily via the [INPUT] and [OUTPUT] connectors on
the DME24N.
2 Control signals within a device group
Introduction to the DME64N/24N
Device group control signals control all DME series devices in the group.
There are two types of device group control signals, as follows:
• Control signals between the computer and the group master DME series unit
• Control signals between the group master DME series unit and the other DME series units
You can use the DME Designer application to control the entire device group, such as sending components
to the devices and setting the parameters as required.
3 Control signals between devices outside the device group
These signals provide communication and control between individual devices.
Included in this category are MIDI messages transferred between [USB] connectors, GPI signals transferred between [GPI] connectors, and remote head amp control signals handled via the [REMOTE] connector.
Type of signals handled by the DME64N/24N
Connector
[USB]
Connector
Audio Signal
Device Control
Word Clock
Reference
Page
–
• Control signals between computer and
DNE64N/24N
• MIDI messages
–
22
–
• Control signals between computer and
DNE64N/24N
• Control signals between DME series
unit.
• Control signals with a controller such as
an AMX or Crestron
–
23
–
Control signals (MIDI commands)
between MIDI controller and DME64N/
24N.
–
30
–
Control signals between GPI device (GPI
controller, etc.) and DME series unit
–
33
[NETWORK]
Connector
[MIDI]
Connector
[GPI]
Connector
[CASCADE]
Connector
(DME64N
only)
[WORD
CLOCK]
Connector
32 channels of
input/output.
Control signals from the digital mixer to
the DME64N
Word clock transmission and
reception to and from other
devices.
Word clock transmission and
reception to and from other
devices.
31
–
–
–
• Control signals to/from an external
device (such as AD8HR head amplifier)
• Control signals for a digital mixer and
internal head amp
• Control signals with a controller such as
an AMX or Crestron
• MIDI messages
–
28
–
–
26
Word clock transmission and
reception to and from other
devices (depending on function
of card).
27
[REMOTE]
Connector
(Audio I/O
Connectors)
(DME24N
only)
8 channels of
input and output.
(I/O Slot)
Number of I/O
Serial signal transmission/reception
channels depends (depending on function of card).
on card.
32
DME64N/DME24N Owner’s Manual
11
System Examples
System Examples
Large systems using CobraNet
Space A
Space B
Computer
ICP1
DME24N
1
Network
Switch
EXT.
CLOCK
NETWORK
96kHz
MID
88.2kHz
MASTER
48kHz
2
3
4
2
3
4
5
6
7
8
5
6
7
8
Analog Out
Analog In
PEAK
IN
SIGNAL
1
44.1kHz
PEAK
SCENE NUMBER
OUT
SIGNAL
MY16-CII
Network
Switch
DME24N
1
EXT.
CLOCK
NETWORK
96kHz
MID
88.2kHz
MASTER
48kHz
2
3
4
2
3
4
5
6
7
8
5
6
7
8
PEAK
1
Analog Out
Analog In
IN
SIGNAL
44.1kHz
PEAK
SCENE NUMBER
SIGNAL
OUT
Introduction to the DME64N/24N
Network
Switch
DME64N
MY16-CII
SCENE
HOME
UTILITY
LEVEL
MUTE
CANCEL
ENTER
MY16-CII x 4
Space C
DME8i-C
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
Analog In
Network
Switch
DME8i-C
Network
Switch
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
Analog In
DME8i-C
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
Network
Switch
Analog In
DME8i-C
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
Analog In
Ethernet
CobraNet
Ethernet Network Switch
Space D
DME8o-C
Analog Out
DME8o-C
Analog Out
DME8o-C
Analog Out
DME8o-C
Analog Out
CobraNet Network Switch
Network
Switch
Network
Switch
12
DME64N/DME24N Owner’s Manual
About DME Designer
About DME Designer
DME64N/DME24N Owner’s Manual
Introduction to the DME64N/24N
DME Designer software enables you to integrate, configure, and control the DME series system from a connected computer.
You can build the DME series audio system using graphic blocks in DME Designer that are displayed on
the computer monitor.
The DME series settings, configuration, and parameter data are transferred from the computer to the DME
series unit via the USB or Ethernet connection.
DME series settings, configuration, and parameter data is sent via USB or Ethernet to the connected DME
series unit. After the data is transmitted, you can disconnect the DME series unit from the computer and use
it as an independent processor.
You can also connect it to a computer and control it in realtime from DME Designer.
If multiple DME series units are connected in the network, DME Designer enables you to build a configuration that includes those units.
Please download the DME Designer application, driver, DME setup manual, and DME Designer Owner’s
Manual at the following URL: http://www.yamahaproaudio.com/
Refer to the “Connecting to a Computer” (page 22) for more information on connecting a computer to the
DME64N/24N. For details on how to install DME Designer and the drivers that are required for connection,
refer to the “DME Setup Manual.”
Refer to the DME Designer Owner’s Manual for setup and operation instructions.
13
Front Panel
The Controls and Connectors
Front Panel
DME64N
!
@
SCENE
1
#
HOME
2
^
)
9
$
UTILITY
*
%
LEVEL
A
B
C
(
CANCEL
MUTE
&
D
ENTER
4
5
6
3
The Controls and Connectors
DME24N
^
)
9
&
A
1
!
@
SCENE
2
3
4
5
6
#
HOME
$
UTILITY
%
LEVEL
*
MUTE
C
(
CANCEL
B
D
ENTER
7
8
7
8
1 [USB] Connector
A computer can be connected here when it is necessary
to program or control the device. When a USB
connection is to be used, the USB-MIDI driver must be
installed on the computer. Refer to the DME Designer
Installation Guide for installation instructions.
2 [EXT. CLOCK] Indicator
When a clock signal from an external device is selected,
the indicator will light green. If the clock signal is not
appropriate the indicator will flash red. The indicator will
go out when the internal word clock is selected.
3 [96kHz] [88.2kHz] [48kHz] [44.1kHz]
Indicator
Normally, the indicator corresponding to the current
word clock frequency will light green. If a problem with
the master clock is detected all of these indicators will
flash red. 2 seconds after a problem is detected with an
external master clock the internal clock will temporarily
be selected. When this happens the indicator
corresponding to the frequency of the internal clock will
light green, and all other indicators will continue to flash
red.
4 [NETWORK] Indicator
Lights while data communication is occurring via the
[USB], [NETWORK], or [CASCADE] connector. Received
data causes the indicator to light in green, while
transmitted data causes the indicator to light in orange.
If a problem occurs the indicator will light in red.
14
DME64N/DME24N Owner’s Manual
Front Panel
5 [MIDI] Indicator
% [MUTE] Button
Lights while data communication is occurring via the
[MIDI] connector. Received data causes the indicator to
light green, while transmitted data causes the indicator
to light orange. The indicator will light green when
reception and transmission occur simultaneously. If a
problem occurs the indicator will light red.
Calls the mute display (page 39). The indicator will light
orange when mute is on. The indicator will light green
when mute is off and the mute display is showing, and
will be off if the mute display is not showing.
^ Dial
Adjusts the value of selected parameters.
6 [MASTER] Indicator
7 [PEAK] Indicator (DME24N only)
Light red when a signal on the corresponding built-in
analog audio input or output ([IN] and [OUT]
connectors) reaches or exceeds -3 dB.
8 [SIGNAL] Indicator (DME24N only)
Light green when a signal with a level greater than -40
dB is present at the built-in analog audio inputs and
outputs ([IN] and [OUT] connectors).
NOTE
The DME64N has no built-in analog audio inputs or
outputs ([IN] and [OUT] connectors).
& [E ] [] [] [ F] Buttons
Move the display cursor in the corresponding directions.
* [CANCEL] Button
Closes the window on the display.
( [ENTER] Button
Confirms and enters a value or setting.
A [PHONES] Jack
A pair of headphones can be plugged in here.
The Controls and Connectors
Lights green when the device is operating as the device
group master (page 9). The indicator will not light if the
device is operating as a device group slave. Refer to
page 45 for device group master setup instructions.
B [PHONES LEVEL] Control
Adjusts the headphone volume. Even when the control is
set to the minimum level, the sound at the headphones is
not completely muted.
C [MONITOR] Button
9 [SCENE NUMBER] Indicator
Shows the current scene number.
) Display
Displays scene information and device parameters.
! [SCENE] Button
Calls the scene recall/store display (page 39). The
scene store display will appear if the button is held for
longer than 2 seconds (page 40). The indicator will light
green while the scene recall or store display is showing.
Calls the monitoring point slot selection display (page
40). When the [ENTER] button is pressed to select a slot,
the monitoring point selection display will appear.
The spectrum analyzer display will then appear when the
[ENTER] button is pressed to select a monitoring point.
The indicator will light green while the monitoring slot/
point or spectrum analyzer display is showing.
D [POWER] Switch
Turns mains power to the device on and off.
CAUTION
@ [HOME] Button
Directly recalls the home (main) display. If pressed while
the main display is showing the [HOME] button steps
through the user-defined parameter display pages (refer
to page 38 in this manual).
Even when the power switch is turned off,
electricity is still flowing to the product all the
minimum level. When you are not using the
product for a long time, make sure to unplug
the power cord from the wall AC outlet.
# [UTILITY] Button
Calls the output level display. If this button is held for
longer than 2 seconds while the main display is showing
the utility display will appear. Switches between the
Utility display pages if pressed while the Utility display is
showing.
$ [LEVEL] Button
Calls the output level setup display (page 39).
The indicator will light green.
DME64N/DME24N Owner’s Manual
15
Rear Panel
Rear Panel
4
DME64N
1 2
6
7
3
DME24N
The Controls and Connectors
1 2
5
)
9
3
4
9
6
7
5
8
1 [AC IN] Connector
3 [GPI] Connector
This is the device’s three-pronged AC power connector.
Connect to the AC mains using the supplied AC power
cord. See “Setup” on page 18 for details.
This Euroblock connector provides access to the unit’s
GPI (General Purpose Interface) interface for transfer of
control signals to and from external equipment. The
DME64N provides 16 channels of GPI input and output,
while the DME24N provides 8 channels. Each input
channel has an IN terminal and a +V terminal. Output
channels each have an OUT terminal and a GND
terminal. The open voltage at the +V terminal is 5V, while
the IN terminal detects voltage changes from 0V ~ 5V.
The OUT terminals output either signal “L” or “H” at a
TTL level.
See “GPI Connection ([GPI] Connectors)” on page 33 for
connection details.
NOTE
Use the supplied AC cord clamp to prevent accidental
disconnection of the AC power.
CAUTION
Even when the power switch is turned off,
electricity is still flowing to the product all the
minimum level. When you are not using the
product for a long time, make sure to unplug the
power cord from the wall AC outlet.
2 Ground Screw
The supplied AC power cable is a 3-wire type, so if the
AC outlet used is properly earthed the DME64N/24N will
be earthed as well. Hum and interference may by further
reduced in some cases by also connecting the earth
screw to an earth point.
NOTE
Connect the device to only one ground point.
Connecting the device to more than ground point can
result in ground loops that can cause increased hum and
noise.
4 [MIDI IN] [MIDI OUT] [MIDI THRU]
Connectors
These are standard MIDI connectors that handle
reception and transmission of MIDI data: [MIDI IN]
receives MIDI data, [MIDI OUT] transmits MIDI data, and
[MIDI THRU] re-transmits MIDI data received at the
[MIDI IN] connector. See “MIDI Connection ([MIDI]
Connectors)” on page 30 for connection details.
5 [WORD CLOCK IN] [WORD CLOCK OUT]
Connectors
These BNC connector receive and transmit word clock
from and to external equipment. See “WORD CLOCK
Connection ([WORD CLOCK] Connectors)” on page 32
for connection details. Word clock settings are available
via the device’s Utility display WCLK page (see page 50
of this document).
16
DME64N/DME24N Owner’s Manual
Rear Panel
6 [NETWORK] Connector
This is a 100Base-TX/10Base-T Ethernet connector for
connection to a computer or other DME series units.
Normally this connector will be connected to a network
switch via an Ethernet cable. When two DME64N/24N
units are to be directly connected a “cross” cable should
be used. See “Ethernet Connection ([NETWORK]
Connector)” on page 23 for connection details.
NOTE
Use a STP (Shielded Twisted Pair) cable for this
connection to prevent electromagnetic interference.
7 [REMOTE] Connector
This 9-pin D-SUB connector allows connection to
Yamaha AD824 or AD8HR remote head amplifier or an
RS-232C/RS-422 compatible controller such as those
from AMX or Crestron. You can also connect a Yamaha
PM5D or DM2000 and control the internal head amps of
DME24N. Refer to page 28 for connection details.
The Controls and Connectors
8 [IN] [OUT] Connectors (DME24N only)
These are balanced Euroblock connectors for analog
audio input and output. The analog signal from
microphones or line sources such as CD players can be
input via the IN connectors, while the OUT connectors
can deliver analog output to powered speakers or
recording equipment. 48V phantom power can be
supplied to the IN connectors (page 51). Refer to page
26 for [IN] and [OUT] connection details.
NOTE
The [IN] and [OUT] connectors each have 24 terminal
pins. Each of the eight inputs and outputs uses three
pins – hot, cold, and ground. Use the supplied 3-pin
Euroblock plugs to connect to the appropriate inputs
and outputs.
9 I/O Slots
Optional Yamaha or third-party Mini-YGDAI cards can be
plugged in here for system expansion. The DME64N has
four I/O slots, while the DME24N has one.
One expansion card can be plugged into each slot.
Refer to “I/O Card Installation” on page 20 for installation
details.
) [CASCADE IN] [CASCADE OUT]
Connectors (DME64N only)
This 68-pin D-SUB connector can be connected to the
CASCADE connector of other devices via a dedicated
cascade cable. The CASCADE connector transmits and
receives control, audio, and word clock signals. Refer to
“Cascade Connection ([Cascade] Connectors” on page
31 for connection details.
DME64N/DME24N Owner’s Manual
17
Setup Procedure
Setup
Setup Procedure
Follow the steps outlined below to prepare the DME64N/24N for operation.
1.
Install any required I/O cards.
Refer to “I/O Card Installation” on page 20 for details.
2.
Connect the AC power cord.
CAUTION
Be sure to turn all devices OFF before connecting AC mains power.
Attach the cable clamp to prevent accidental disconnection.
Attaching the cable clamp.
Setup
Be sure to properly ground the device to prevent possible electrical shock.
First plug the female-connector end of the AC cord into the [AC IN] socket on the rear panel of the
DME64N/24N, then plug the male plug into an appropriate AC mains outlet. Make sure the AC power to be
used complies with the conditions marked on the top cover of the device.
CAUTION
Use only the AC power cord supplied with the DME64N/24N. If the supplied cord is lost or damaged
and needs to be replaced, contact your Yamaha dealer. The use of an inappropriate replacement
can pose a fire and shock hazard!
The type of AC power cord provided with the DME64N/24N may be different depending on the
country in which it is purchased (a third prong may be provided for grounding purposes). Improper
connection of the grounding conductor can create the risk of electrical shock. Do NOT modify the
plug provided with the DME64N/24N. If the plug will not fit the outlet, have a proper outlet installed
by a qualified electrician. Do not use a plug adapter which defeats the grounding conductor.
Security Cover Mounting
Security cover mounting screw holes (M3 size) are provided on the front panel of the unit. The spacings are 423mm
width and 96mm (DME64N) / 52mm (DME24N) height. See “Dimensions” on page 65 for details. A security cover
made by the customer or contractor can be attached to the front panel via these mounting holes to prevent
accidental operation. Yamaha cannot supply a security cover.
When mounting a cover make sure that the screws used do not go deeper than 15 millimeters into the front panel.
Also, to ensure that the cover does not come in contact with the panel controls, leave a space of about 20 millimeters
between the front panel and the cover.
3.
Install the DME Designer software and necessary drivers on the computer to be used for
device group control.
See the “DME Setup Manual” (PDF file) for details.
18
DME64N/DME24N Owner’s Manual
Setup Procedure
4.
Connect devices.
• Network connection
Ethernet connection (page 23)
USB connection (page 22)
• Analog connection (page 26)
• External device connection
Remote connection (page 28)
MIDI connection(page 30)
CASCADE connection(page 31)
WORD CLOCK connection(page 32)
GPI connection (page 33)
5.
Turn power to the computer, DME64N/24N, and related devices on. Press the DME64N/24N
[POWER] switch to turn it on.
CAUTION
To prevent the initial power-on surge from generating a large noise spike or damaging your speaker
system, turn devices on in the following order: audio sources, mixer and/or recorders, and finally
power amplifiers. Reverse this order when turning power off.
Setup
No information will appear on the display the first time the device is turned on. The appropriate scene and
other data must first be transferred to the device from the DME Designer.
Refer to the “DME Setup Manual” (PDF file) for details.
Once the appropriate data has been transferred to the device, the current number and name will appear
on the display:
If any scene data has been stored in the DME64N/24N, the current scene and its name will be displayed.
6.
Set up the DME64N/24N operation parameters.
See the “Utility Display” section on page 43 for details.
NOTE
The “NET” page settings must be set up as required before using the unit for the first time.
7.
Launch the DME Designer application, create configuration and transfer.
DME Designer setup, operation, and data transfer instructions can be found in the DME Designer Manual.
This completes preparation of the DME64N/24N system.
DME64N/DME24N Owner’s Manual
19
I/O Card Installation
I/O Card Installation
The DME64N has four I/O card slots, and the DME24N has one I/O card slot. The number of audio input channels
available on the DME64N/24N can be increased by plugging the appropriate Mini-YGDAI I/O card(s) into the available
card slot(s).
Compatible I/O Cards
For the latest information on what cards can be used with the DME64N/24N, visit the Yamaha Pro Audio
website at: http://www.yamahaproaudio.com/
Setup
20
DME64N/DME24N Owner’s Manual
I/O Card Installation
I/O Card Installation Procedure
1.
Make sure that the DME64N/24N power is OFF.
If the power is on, turn it off.
2.
Loosen the two card slot screws and remove the slot cover, as shown in the diagram.
NOTE
3.
Setup
The slot cover and screws will need to be re-attached if the I/O card is later removed from the slot, so keep
them in a safe place.
Slide the I/O card into the slots in the guide rails, as shown in the diagram, and push the
card into the slot.
Be sure to push the card all the way back into the slot so that the card contacts make proper contact with
the slot connector.
Guide Rail
CAUTION
4.
When inserting the card, align both sides of the card with the guide rails in the slot of the host
device.
Secure the card with the attached screws.
CAUTION
Be sure to tighten the screws securely. If the screws are left loose proper contact may be lost and
malfunction of damage may result.
DME64N/DME24N Owner’s Manual
21
USB Connection
Connecting to a Computer
USB Connection
NOTE
• Refer to the “DME Setup Manual” (PDF file) for details on installing USB-MIDI Driver and DME Designer.
• Make sure that the USB-MIDI Driver’s THRU setting is “OFF.”
USB connections can be used in the following two ways:
(1) Control the DME64N/24N from DME Designer.
(2) Connect to any individual DME64N/24N and control that DME64N/24N unit by transmitting MIDI commands from a MIDI sequencer or similar software.
NOTE
• The computer on which DME Designer is running can be connected to either the group master or a slave DME series
unit.
• The correspondence between the MIDI commands to be received/transmitted and the scene parameters can be set up
using DME Designer.
• The USB port being used by DME Designer is not available for use by a MIDI sequencer or other application.
USB Cable
Device Group
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
DME Satellite
Connecting to a Computer
Ethernet Cable
Computer
(Running DME Designer.)
Network Switch
Ethernet Cable
Ethernet Cable
DME64N/24N
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
DME Satellite
SCENE
HOME
UTILITY
LEVEL
MUTE
CANCEL
ENTER
USB Cable
Computer
(Running MIDI
Sequencer or
similar application.)
Be sure to follow the procedure below when you make a USB connection with a computer. Otherwise, the
computer and/or DME64N/24N may freeze, resulting in damages or loss of data. If the computer or
DME64N/24N freezes, turn the power to the DME64N/24N off and then on, then restart the computer.
CAUTION
22
• Before you connect the DME64N/24N to the computer via USB, cancel the computer’s energy saving
mode (such as Suspend, Sleep, or Stand-by mode).
• Before turning on the power to the DME64N/24N, first connect its [USB] connector to the computer’s
USB port.
• Before turning the power to the unit on or off, and before connecting or disconnecting the USB
cable, take the following actions:
- Quit all open applications.
- Make sure that the DME64N/24N is NOT transferring any data.
• Be sure to wait six seconds or more between turning the power to the unit on and then off (or off and
then on), or between connecting and disconnecting (or vice versa) the USB cable.
DME64N/DME24N Owner’s Manual
Ethernet Connection ([NETWORK] Connector)
Ethernet Connection ([NETWORK] Connector)
To control the DME64N/24N from the computer via Ethernet, use an Ethernet cable to connect the [NETWORK] connector on the rear panel of the DME64N/24N to the computer, then install DME-N Network Driver.
NOTE
• Refer to the “DME Setup Manual” (PDF file) for details on installing DME-N Network Driver.
• Appropriate IP addresses must first be assigned to all devices connected to an Ethernet network.
Two DME series units directly connected via Ethernet
SCENE
HOME
UTILITY
LEVEL
MUTE
CANCEL
ENTER
DME64N/24N
Ethernet Cable
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
DME Satellite
USB Cable
DME64N/DME24N Owner’s Manual
Connecting to a Computer
You can connect devices in the same device group directly to each other using Ethernet cables, without
connecting them to a network switch.
A cross cable or straight cable can be used since the DME series supports Auto MDI/MDI-X. In this case,
set Link Mode on both units to the same setting. Devices in different subnet (different network address)
groups can be connected via a router or layer-3 compliant network switch.
23
Ethernet Connection ([NETWORK] Connector)
Control from a computer in the same subnet group
Device Group
Group Master
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
DME Satellite (IP address: 192.168.0.7)
Ethernet Cable
Ethernet Cable
Network Switch
Ethernet Cable
Computer
(IP address:
192.168.0.100)
Ethernet Cable
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
DME Satellite
(IP address: 192.168.0.3)
(Master ID: 7)
SCENE
HOME
UTILITY
LEVEL
MUTE
CANCEL
ENTER
DME64N/24N
(IP address: 192.168.0.250)
(Master ID: 7)
NOTE
Connecting to a Computer
• The IP addresses in the diagram are examples.
• Use a network switch that is compatible with 100Base-TX/10Base-T network speeds.
The maximum length of a cable between a network switch and the DME series is 100 meters. Due to the quality of cables
and network switch performance, however, proper operation at the maximum length cannot be guaranteed in some
cases.
Use a STP (Shielded Twisted Pair) cable to prevent electromagnetic interference.
• If you are using multiple DME series units, set Link Mode on each unit to the same setting. Yamaha recommends that you
select 100Base-TX for the Link Mode setting.
Control from a computer with a different subnet
Device Group
Port settings
Destination network address: 192.168.0.0
Subnet mask: 255.255.255.0
Gateway: 192.168.0.254
Group Master
INPUT
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
DME Satellite (IP address: 192.168.0.5)
Ethernet Cable
Network Switch
Ethernet
Cable
Ethernet Cable
Ethernet Cable
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
INPUT
DME Satellite
(IP address: 192.168.0.3)
(Master ID: 5)
SCENE
HOME
UTILITY
LEVEL
MUTE
CANCEL
ENTER
DME64N/24N
(IP address: 192.168.0.12)
(Master ID: 5)
24
DME64N/DME24N Owner’s Manual
Ethernet Cable
Computer
INPUT
USB
Router or
Layer-3
Compliant
Network
Switch
Ethernet Connection ([NETWORK] Connector)
Connecting multiple device groups
Device Group 1
Device Group 2
Group Master
Group Master
INPUT
USB
INPUT
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
INPUT
DIGITAL MIXING ENGINE SATELLITE
INPUT
DME Satellite
(IP address: 192.168.0.2)
Ethernet Cable
DME Satellite
(IP address: 192.168.0.3)
Ethernet Cable
Network Switch
Network Switch
Ethernet Cable
Ethernet Cable
Ethernet Cable
Ethernet Cable
SCENE
HOME
UTILITY
LEVEL
MUTE
CANCEL
ENTER
SCENE
DME64N/24N
(IP address: 192.168.0.100)
(Master ID: 2)
Ethernet Cable
HOME
LEVEL
MUTE
CANCEL
ENTER
DME64N/24N
(IP address: 192.168.0.200)
(Master ID: 3)
INPUT
INPUT
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
DIGITAL MIXING ENGINE SATELLITE
USB
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
INPUT
DIGITAL MIXING ENGINE SATELLITE
INPUT
DME Satellite
(IP address: 192.168.0.40)
(Master ID: 2)
DME Satellite
(IP address: 192.168.0.10)
(Master ID: 3)
Connecting to a Computer
USB
UTILITY
Computer
(IP address: 192.168.0.1)
DME64N/DME24N Owner’s Manual
25
Analog Audio Connection ([IN] and [OUT] Connectors)
Audio I/O Connection
Analog Audio Connection ([IN] and [OUT] Connectors) (DME24N only)
The DME24N includes [IN] and [OUT] connectors for 8 channels of analog audio input and output. Wire
the supplied Euroblock plugs as shown below. Head amplifier gain and phantom power settings can be
made via the Utility display HA page described on page 52 of this manual, or via the DME Designer
application.
Euroblock Connection
Please be sure to use the supplied Euroblock plugs. If you lose them, contact your nearest Yamaha dealer.
Cable preparation
approx.
7 mm
• To prepare the cable for attachment to a Euroblock connector, strip the wire as
shown in the illustration using stranded wire to make connections. With a
Euroblock connection, the stranded wire may be prone to breakage because of
metal fatigue due to the weight of the cable or due to vibration. When rackmounting your equipment, use a lacing bar when possible to bundle and fasten
the cables.
NOTE
1.6 mm
or less
Do not tin (plate with solder) the stranded wire.
• If cables will be frequently connected and disconnected, as in the case of a
portable installation, we recommend that you use ferrules with insulation sleeves.
Use a ferrule whose conductor portion has an external diameter of 1.6 mm or
less, and a length of approximately 7 mm (such as the AI0,5-6WH made by the
Phoenix Contact corporation).
1.
Loosen terminal screws.
Audio I/O Connection
Loosen.
Slotted Screwdriver
Terminal Screw
Euroblock Plug
NOTE
A slotted screwdriver with a blade width of about 3 millimeters and under is
recommended.
2.
Insert cables.
+
26
DME64N/DME24N Owner’s Manual
–
G
3 mm and under
approx.
7 mm
I/O Slots
3.
Securely tighten terminal screws.
Pull the cables (not too strongly) to confirm that they are securely connected.
4.
Plug the Euroblock plug into the panel connector.
I/O Slots
Audio I/O Connection
The DME64N has four I/O card slots, and the DME24N has one I/O card slot. The number of audio input
channels available on the DME64N/24N can be increased by plugging the appropriate Mini-YGDAI I/O
card(s) into the available card slot(s). Some types of cards also provide control and/or word clock
transmission and reception functionality.
Refer to “Compatible I/O cards” (page 20) for details on the cards that can be used.
For details on how to install cards, refer to “I/O card Installation Procedure” (page 21).
DME64N/DME24N Owner’s Manual
27
Remote Connection ([REMOTE] Connector)
Connecting to an External Device
Remote Connection ([REMOTE] Connector)
The [REMOTE] connector of the DME64N/24N can be connected to remotely-controllable Yamaha AD8HR
or AD824 head amplifiers (pre-amps), digital mixers, or RS-232C compatible controllers (such as those from
AMX or Crestron). The [REMOTE] connector also transmits and receives MIDI messages.
Controlling external head amplifiers from the DME64N/24N
You can remotely control the AD8HR or AD824 head amplifier settings from DME Designer. Up to eight
AD8HR/AD824 head amplifiers can be connected.
When connecting to a combination of AD8HR and AD824 head amplifiers, be sure to place the AD8HR units
closest to the DME64N/24N in the chain, otherwise the AD8HR or AD824 unit(s) may not be properly recognized by the DME64N/24N. For details about the settings, refer to the “Ext HA Ctrl” in “Remote page” on
page 49.
D-SUB 9-pin Cable (Interlink Crossover)
Set to Remote
(422)
REMOTE
HA REMOTE 1
HA REMOTE 2
HA REMOTE 1
HA REMOTE 2
DME64N/24N
AD8HR
COM PC/RS-422
AD824
AD8HR
COM RS-422
COM PC/RS-422
AD824
COM RS-422
COM PC/RS-422
AD824
NOTE
Connecting to an External Device
Only control signals are transmitted and received via the REMOTE connection. Audio connections must be
made separately.
28
DME64N/DME24N Owner’s Manual
Remote Connection ([REMOTE] Connector)
Controlling a DME24N’s internal head amps from a digital mixer
The internal head amp settings of a DME24N can be remotely controlled from a digital mixer such as the
Yamaha PM5D or DM2000.
Connect the digital mixer to the DME series’ [REMOTE] connector, and use an Ethernet cable to make connections between the [NETWORK] connectors of the DME series. From the digital mixer, DME series units
can be controlled as an AD8HR.
The gain and the phantom power (+48V) can be controlled. For details about the settings, refer to the “Int
HA Ctrl” in “Remote page” on page 49.
D-SUB 9-pin Cable
REMOTE
REMOTE
Ethernet Cable
1
EXT.
CLOCK
NETWORK
96kHz
MID
88.2kHz
MASTER
48kHz
2
3
4
2
3
4
5
6
7
8
5
6
7
8
PEAK
IN
SIGNAL
1
44.1kHz
PEAK
SCENE NUMBER
OUT
SIGNAL
DME64N/24N
1
EXT.
CLOCK
NETWORK
96kHz
MID
88.2kHz
MASTER
48kHz
2
3
4
2
3
4
5
6
7
8
5
6
7
8
Network
Switch
PEAK
IN
SIGNAL
1
44.1kHz
PEAK
SCENE NUMBER
SIGNAL
OUT
DME64N/24N
Digital Mixer
NOTE
Only one mixer can be connected within each device group.
The digital mixer can be connected to any DME series unit, whether it is the group master or a slave unit.
The ID number of the DME series unit being remotely controlled is specified from DME Designer.
For details on making this setting, refer to the “DME Designer Owner’s Manual.”
If the connection between DME series units is broken, it will no longer be possible to communicate with DME
units of an ID number that follows the disconnected DME.
The variable range of GAIN differs between the AD8HR and the DME24N. You cannot use the mixer to
specify a value that exceeds the variable range of the DME24N.
Connecting to an External Device
Controlling the DME64N/24N from an external device
You can remotely control the DME64N/24N from a connected RS-232C or RS-422 compatible controller,
such as those from AMX or Crestron.
When connecting a remote controller via RS-232C or RS-422, be sure to set the “Utility” display “Remote
page” (see manual page 45) “Rmt Ctrl” parameter to match the controller being connected. Also, do
change this setting while the unit is connected. Doing so can damage the unit.
NOTE
Refer to “DME Remote Control Protocol Specifications” on the Yamaha web site for more information on
communication protocols used to control the DME64N/24N from an external device (such as those from
AMX or Crestron).
http://www.yamahaproaudio.com/
DME64N/DME24N Owner’s Manual
29
Network Connection ([NETWORK] Connectors)
Network Connection ([NETWORK] Connectors)
You can connect a controller such as the AMX or Crestron to DME64N/24N via Ethernet, and remotely
control multiple DME64N/24N units. For details about the settings, refer to the “Rmt Ctrl” in “Remote page”
on page 48.
• The port used for remote control is specified from DME Designer. For details on making this setting, refer
to the “DME Designer Owner’s Manual.”
• Refer to “DME Remote Control Protocol Specifications” on the Yamaha web site for more information on
communication protocols used to control the DME64N/24N from an external device (such as those from
AMX or Crestron).
http://www.yamahaproaudio.com/
MIDI Connection ([MIDI] Connectors)
In this case connection is made to the rear-panel [MIDI] connectors. MIDI commands are sent to the
DME64N/24N from a MIDI device. Refer to “MIDI Page” on page 49 for MIDI setup details.
NOTE
The DME Designer can be used to set up the system so that scene recall operations and user parameter
control can be carried out from connected MIDI devices. Refer to the DME Designer manual for details.
By connecting the [MIDI OUT] terminal of a digital mixer (such as the DM2000) to the [MIDI OUT] of the
DME64N/24N and making the proper settings on the mixer and the DME64N/24N, you can change scenes
by sending program change messages from the mixer.
MIDI Cable
MIDI OUT
MIDI IN
DME64N/24N
DM2000 Digital Mixer or Other Controller
Connecting to an External Device
If the [MIDI OUT] connector of the DME64N/24N is connected to the [MIDI IN] connector of an SPX2000 or
similar digital effect unit, and if the DME64N/24N and SPX2000 are set up appropriately, DME64N/24N
program change operations will case the corresponding effect to be recalled on the effect unit.
MIDI Cable
MIDI OUT
MIDI IN
SPX2000 or Other Digital Effect Unit
DME64N/24N
30
DME64N/DME24N Owner’s Manual
Cascade Connection ([Cascade] Connectors) (DME64N only)
Cascade Connection ([Cascade] Connectors) (DME64N only)
The rear-panel [CASCADE] connector can be connected to the [CASCADE] connector on another
DME64N/24N or other compatible device via a dedicated cascade cable for bidirectional transfer of
control, audio, and word clock signals. The communication direction automatically switches to
unidirectional when connecting to a mixer such as the PM5D, or bidirectional when connecting to another
DME64N/24N unit.
Up to eight DME64N units can be cascade connected.
In the unidirectional mode the audio signal flow is from the [CASCADE OUT] connector to the [CASCADE
IN] connector. For bidirectional communication the data flows in both directions within a single cable, and
input on the same channel from other DME64N units is summed (bus sharing). The total number of audio
channels that can be connected to a mixer or DME64N/24N unit is 32.
Word clock is continuously output from both the [CASCADE IN] and [CASCADE OUT] connectors, and is
received by the corresponding [CASCADE IN] or [CASCADE OUT] connector on the connected device.
In all cases the [CASCADE OUT] of one device must be connected to the [CASCADE IN] connector of the
other. Do not connect [CASCADE IN] to [CASCADE IN], or [CASCADE OUT] to [CASCADE OUT].
NOTE
Maximum length by the optional dedicated Cascade cables
Unidirectional Cascade connection: 200m (44.1/48kHz), 100m (88.2/96kHz)
Bidirectional Cascade connection: 100m (44.1/48kHz), 30m (88.2/96kHz)
Cascade Connection Example
Unidirectional Cascade Connection
68-pin Half-pitch D-SUB Cable
IN
OUT
DME64N
Bidirectional Cascade Connection
DME64N
68-pin Half-pitch D-SUB Cable
OUT
68-pin Half-pitch
D-SUB Cable
IN
PM5D
DME64N
68-pin Half-pitch
D-SUB Cable
IN
OUT
OUT
Connecting to an External Device
IN
DME64N
NOTE
Never create a full cascade loop using only DME64N units!
NOTE
It is also possible to remotely control DME series units from the PM5D via a CASCADE connection. In such
cases assign the nearest DME64N unit to the PM5D as the device group master. When using a DME64N/24N
together with the DME Satellite, you must assign the DME Satellite as the master.
Another method of remotely controlling a DME series from a PM5D is via CobraNet connections to MY16-C or
MY16-CII cards.
All DME series units to be controlled from the PM5D must be in the same device group, and the host address
of the device group master must be set to “2.” However, if the PM5D is version 2.20 or higher and the DME
Satellite is version 3.07 or higher, you can set the parameter to any number.
For information on the PM5D DME CONTROL function refer to the PM5D/PM5D-RH Owner’s Manual or to the
“Cascade Setup Guide” available at the Yamaha website.
http://www.yamahaproaudio.com/
DME64N/DME24N Owner’s Manual
31
WORD CLOCK Connection ([WORD CLOCK] Connectors)
WORD CLOCK Connection ([WORD CLOCK] Connectors)
Word clock signals are transferred to and from external devices via the [WORD CLOCK IN] and [WORD
CLOCK OUT] connectors. The [WORD CLOCK OUT] connector can be used to supply the DME64N/24N
word clock to external equipment. Word clock is continuously output by the DME64N/24N during normal
operation. The word clock signal from an external device can be received via the [WORD CLOCK IN]
connector. Refer to the Utility display WCLK page described on page 50 of this manual for details.
NOTE
Word clock can also be received and transmitted via a Mini-YGDAI card installed in an I/O slot, or the
[CASCADE IN] and [CASCADE OUT] connectors. It is necessary to specify whether the DME64N/24N will use
the internal word clock or an external word clock for synchronization.
NOTE
A device transmitting the word clock signal that will be used by other devices for synchronization is the “word
clock master,” while devices received the word clock are “word clock slaves.”
WC OUT
(BNC)
WC IN
(BNC)
Word Clock
Master
DME64N/24N
Word Clock Slave
To distribute the word clock signal from one device to multiple slave devices, either a word clock
distribution box or daisy-chained connection can be used.
Distribution Box Connection
Word Clock
Master
Word Clock
Distribution Box
WC OUT (BNC)
WC IN (BNC)
DME64N/24N
WC IN (BNC)
DME64N/24N
Word Clock Slave
WC IN (BNC)
WC IN (BNC)
DME64N/24N
Word Clock Slave
DME64N/24N
Word Clock Slave
Word Clock Slave
Connecting to an External Device
Daisy Chain Connection
NOTE
This method is not recommended for large systems.
Word Clock
Master
WC OUT (BNC)
WC IN
(BNC)
WC OUT
(BNC)
DME64N/24N
Word Clock Slave
32
DME64N/DME24N Owner’s Manual
WC IN
(BNC)
WC OUT
(BNC)
DME64N/24N
Word Clock Slave
WC IN
(BNC)
DME64N/24N
Word Clock Slave
GPI Connection ([GPI] Connectors)
GPI Connection ([GPI] Connectors)
GPI (General Purpose Interface) device (GPI controller, etc.) can be connected to the rear-panel [GPI]
connectors. Using GPI a variety of control signals can be transferred between the DME64N/24N and
external controllers or other devices. The optional CP4SW, CP4SF, and CP1SF control panels are also
connected via GPI.
NOTE
For more information on the CP4SW, CP4SF, and CP1SF control panels refer to “CP4SW, CP4SF, and CP1SF”
in the Appendix of this manual (page 51).
The DME64N provides 16 channels of GPI input and output, and the DME24N provides 8 channels. Each
channel has an IN terminal, a +V terminal, an OUT terminal and a GND terminal. The +V terminals have an
open-terminal voltage of 5 volts. The IN terminals can detect a full range of input voltages from 0V through
5V, while the OUT terminals output either signal “L” or “H” at a TTL level.
The parameters for each GPI input and output are assigned via the DME Designer application.
NOTE
The DME Designer can be used to set up the system so that scene recall operations and user parameter
control can be carried out from connected GPI control devices. Refer to the DME Designer manual for details.
Euroblock connectors are used for all GPI input and output connections. Euroblock connection methods
are described in “Euroblock Connection” on page 26 in this manual.
Example: Controlling the
DME64N/24N from a switch.
GPI Connection
IN
+V
Example: Controlling the
DME64N/24N via a 10k ohm
linear taper potentiometer.
GPI Connection
IN
+V
Example: Lighting external
LED indicators from the
DME64N/24N.
GPI Connection
OUT
GND
GND
Max. 16mA
CAUTION
Make sure that the current
between the OUT and GND [GPI]
connectors is less than 16mA.
Connecting to an External Device
Continuous
potentiometer
NOTE
GPI connector calibration procedure is described on page 51 of this manual, in the Utility display GPI page.
DME64N/DME24N Owner’s Manual
33
Basic Operation
Panel Operation and Displays
Basic Operation
By pressing the panel buttons it is possible to select the DME64N/24N Main display, Utility display, and Parameter Edit
displays that allow individual settings to be edited and changed. refer to the pages listed below for more detailed
information about each display.
[HOME] button Main Display (page 35)
The Main display can be directly recalled from any display other than the Main display by pressing the
[HOME] button. The Main display shows the current scene information.
HOME
[HOME] button User Defined Button Page Selection (page 38)
Pressing the [HOME] button while the Main display is shown sequentially selects the four User Defined
Button pages.
HOME
Main display
Switches the pages of the User Defined Button
[MUTE] button Mute Display (page 39)
[LEVEL] button Output Level Display (page 39)
[SCENE] button Scene Recall Display (page 39)/Scene Store Display (page 40)
These buttons can be pressed from the Main or Utility displays to directly call the related parameter edit
displays.
[MONITOR] button Monitor Point Selection Display (page 40)
This function is useful for level monitoring. When the button is pressed the monitor point selection display
will appear, and the spectrum analyzer display will appear when a selection has been made.
Panel Operation and Displays
[UTILITY] button Utility Display (page 43)
The Utility display appears when the [UTILITY] button is pressed for longer than two seconds while the
Main display is showing.
The Utility display includes a number of pages that can be selected in sequence by repeatedly pressing
the [UTILITY] button.
34
DME64N/DME24N Owner’s Manual
Main Display
Main Display
The Main display will appear in a few seconds after the
power is turned on. The Main display shows information
about the current scene.
Buttons are selected for editing by using the cursor
buttons – [ E ] [ ] [ ] [ F ] – to select the button,
and then pressing [ENTER].
NOTE
User Defined Button settings are common to the device
group.
NOTE
Nothing will appear on the display if no scene data is
stored in the DME64N/24N scene memory (this is the
case when the unit is initially shipped, for example).
Up to 24 parameters can be accessed from the
DME64N/24N or ICP1 control panel for each scene. Six
parameters are shown on the Main display at a time.
3
5
6
7
2
1
4
4 Page Scroll Bar
The scroll bar provides an indication of which parameter
page is currently being displayed. 4 pages are
available, and the scroll bar moves one position to the
right each time the [HOME] button is pressed and a new
page of parameters is selected, and then back to the
leftmost position after the rightmost position has been
reached.
NOTE
Scroll bar operation is independent for each DME64N/
DME24N unit, and is not linked within a device group.
3
1 Scene Information
5 Mute Indicator
The current scene number and name. Scene names can
be entered by using the DME Designer application.
A maximum of 12 one-byte (Roman) characters can be
displayed in a scene name. When “two-byte” characters
are to be used for languages such as Japanese, the total
number of displayable characters is reduced
accordingly.
When the power is turned on the last scene selected
before the power was turned off is automatically
recalled.
Shows the current mute ON/OFF status.
2 Edit Indicator
If a parameter is changed after recalling a scene, a dot
will appear in the scene number indicator, and “EDIT”
will appear in the display.
: Mute ON
: Mute OFF
6 Output Level Indicator
Displays the current output level in 10 increments.
The longer the “bar,” the higher the output level.
7 Panel Lock Icon
This icon appears when the panel lock function is turned
ON.
: Panel Lock ON (Panel controls locked)
Panel Operation and Displays
3 User Defined Button Names
Displays the User Defined Button. The buttons are
specified by using the DME Designer application.
“No Assign” settings in DME Designer are displayed as
dotted lines. When [Parameter Value Edit] is selected the
display will be a solid line. When [Direct Parameter
Value], [Scene Change], [GPI Out], or [Play Wav File] are
selected, the display will be inverted.
A maximum of 24 buttons can be made available for
user control, but only six buttons can be shown in any
one display page. Press the [HOME] button to switch to
other available button pages. A maximum of 8 one-byte
(Roman) characters can be displayed in a button name.
When “two-byte” characters are to be used for
languages such as Japanese, the total number of
displayable characters is reduced accordingly.
DME64N/DME24N Owner’s Manual
35
Parameter Edit Displays
Parameter Edit Displays
Panel Lock
The panel controls can be “locked” to prevent
accidental mis-operation.
To activate the panel lock function simultaneously
press and hold the [HOME] and [ENTER] buttons for
longer than 2 seconds.
The panel lock icon will appear on the Main display
when the panel is locked.
Panel lock icon
Panel Lock can be disengaged by pressing the
[CANCEL] button for longer than 2 seconds.
Parameter Edit displays will appear when the [SCENE],
[MUTE], [MONITOR] or other button is pressed to allow
scene changes, level adjustment, and other settings to
be edited as required. Parameter Edit displays are also
used to edit utility parameters.
In most cases the desired parameter edit page can be
accessed by selecting the item you want to edit in the
appropriate display by using the cursor [ E ], [ ],
[ ], and [ F ] buttons, and then pressing the [ENTER]
button.
There are basically three types of parameters that can
be accessed via a Parameter Edit display:
• Numeric values
• Lists
• ON/OFF switches
NOTE
Numeric Parameters
The panel lock function can be set up to lock just the
panel buttons (“Key Only”), or the panel buttons and GPI
control (“Key+GPI”). You can also select whether or not
the panel lock function is automatically engaged when
the unit is initially turned on. This selection can be made
via the Utility display “Lock” page (refer to the page 47).
Numeric parameters can be edited in a number of ways,
and depending on the parameter a fader, knob, or
minimum and maximum values may appear to the left of
the numeric value.
A Numeric Value with a fader
1
5
2
4
A Numeric Value with a Knob
1
5
3
Panel Operation and Displays
4
1 Name of parameter selected for editing
2 Fader
3 Knob
4 Minimum and maximum values
5 Current value
36
DME64N/DME24N Owner’s Manual
Parameter Edit Displays
Some Parameter Edit displays have just one numeric
parameter, while other may have two or more.
2.
Rotate the dial to edit the value as required.
3.
Repeat step 1 to select the next value to be
edited, use the dial to edit as required, and
repeat until all values have been edited as
required.
4.
When all values have been edited, press the
[ENTER] button. A confirmation window will
appear: press [ENTER] one more time to
confirm the edits and close the window.
Parameter Edit Display with One Numeric Parameter
1.
Numeric values can be changed by rotating
the dial. Dial rotation produces an
immediate, corresponding change in the
selected value.
ENTER
2.
Press the [ENTER] button to close the
Parameter Edit display after the value(s)
have been edited as required.
Parameter Edit Display with Multiple Numeric
Parameters
ENTER
Use the cursor buttons – [ E ] [ ] [ ] [ F ]
– to select the value to be edited.
Panel Operation and Displays
NOTE
1.
You can close the window without changing any values
by pressing the [CANCEL] button rather than the
[ENTER] button.
DME64N/DME24N Owner’s Manual
37
Parameter Edit Displays
List Parameters
ON/OFF Parameters
List parameters allow you to make one selection from a
list of possibilities.
Parameters that are either ON or OFF are edited via this
type of display (e.g., Mute Parameter Edit display in
“Mute Switching” on page 39).
Rotate the dial to scroll up or down the list. In some
cases the centermost item on the display will be always
highlighted as the list is scrolled, and in others the same
item will remain highlight as the list is scrolled up or
down.
1.
Rotate the dial clockwise to select ON, or
counterclockwise to select OFF.
2.
Press enter to confirm the selection and
close the window.
List Parameter with Center Item Always Highlighted
Parameter Edit displays will also appear when the
[SCENE], [MUTE], [MONITOR] or other button is
pressed.
These allow scene changes, level adjustment, and other
settings to be edited as required.
1.
Use the dial to scroll up or down the list.
As you scroll the centermost item on the display will
be highlighted.
2.
Press the [ENTER] button to select the
highlighted item and close the window.
List Parameter with Scrolling Highlight
1.
Press the [ENTER] button to highlight the
centermost item on the display.
NOTE
Panel Operation and Displays
In some cases a confirmation dialog will appear when
the [ENTER] button is pressed. If this occurs press the
[ENTER] button a second time to continue.
3.
1.
If the Main display is not showing, press the
[HOME] button to recall it.
2.
Press the [HOME] button until the page
containing the parameter to be edited
appears.
3.
Use the [ E ] [ ] [ ] [ F ] buttons select
the parameter to be edited.
4.
Press the [ENTER] button.
The Parameter Edit display for the selected User
Defined Button will appear.
Use the dial to scroll up or down the list.
As you scroll the highlighted selection will remain
highlighted, and will scroll up or down with the list.
2.
Editing User Defined Button
Press the [ENTER] button to select the
highlighted item and close the window.
NOTE
User Defined Button can be of all three types: numeric,
list, and ON/OFF.
NOTE
When editing from an ICP1 control panel, the [F1] ~ [F6]
buttons are used for button selection.
5.
Edit the User Defined Button as required.
Refer to “Parameter Edit Displays” on page 36 for
editing procedures.
NOTE
Any changed User Defined Button values will be lost if
the power is turned off or if scenes are changed.
However, if the Last.Mem.Resume setting is ON, the
setting will be preserved even when the power is turned
off. To preserve the changed values, store the scene
data.
38
DME64N/DME24N Owner’s Manual
Parameter Edit Displays
Mute Switching
Turns the DME64N/24N output mute function ON or OFF.
1.
Scene Recall
This procedure recalls a new scene (refer to page 10).
Press the [MUTE] button.
NOTE
The Mute Parameter Edit display will appear.
The same procedure is used for scene recall from an ICP1
control panel.
1.
Press the [SCENE] button.
The Scene Recall display will appear.
2.
Select Mute ON or OFF.
The mute function is turned on or off as described
in “ON/OFF Parameters” on page 38.
NOTE
To access this function from the ICP1 control panel, hold
the [F6] button for longer than 2 seconds.
2.
Select a new scene.
Scenes are selected as described in the “List
Parameters” section on page 38.
NOTE
All outputs in the device group, including the [PHONES]
jack, are muted.
Output Level Control
Adjust the output level of the DME64N/24N.
3.
Press the [ENTER] button.
A confirmation window will appear.
NOTE
Output level settings apply individually to each DME64N/
24N unit. There is no overall device group setting.
This function cannot be accessed from the ICP1 control
panel.
Press the [LEVEL] button.
The “Output Level” Parameter Edit display will
appear.
2.
Adjust the numeric output level parameter
as required.
4.
Press the [ENTER] button again.
The new scene will be selected.
CAUTION
Panel Operation and Displays
1.
Don’t turn the power off during a scene recall
operation. Doing so can cause corruption of
the current scene data.
The Output Level parameter is adjusted as
described in “Numeric Parameters” on page 36.
The graphic fader provides a visual indication of the
current output level setting.
DME64N/DME24N Owner’s Manual
39
Parameter Edit Displays
NOTE
Scenes can also be changed from a computer or GPI/
MIDI controller connected to the device.
The DME Designer application is used to make scene
changes from a computer. If a GPI/MIDI controller is to
be used for changes it must be initially set up for scene
change control by using the DME Designer.
Monitoring
The monitor functions allow you to monitor the audio
signal at the inputs or outputs of I/O slots, points
between components, and other critical monitoring
points.
NOTE
NOTE
If head amplifier parameters are included in the recalled
scene data, the head amplifier settings will be changed
accordingly.
User-defined monitoring functions, such as monitoring at
points between components, must specified via the DME
Designer application.
NOTE
These functions cannot be accessed from the ICP1.
Scene Store
Stores the current scene data for later recall.
1.
Press the [MONITOR] button.
The slots available for monitoring will be shown in
the parameter list.
NOTE
This function can be accessed in the same way from the
ICP1.
1.
Press the [SCENE] button for longer than 2
seconds.
A confirmation window will appear on the display.
2.
2.
Press the [ENTER] button.
This stores the scene data in the current scene
memory.
NOTE
Press the [CANCEL] button if you want to abort the
scene store operation.
NOTE
Panel Operation and Displays
If head amplifier settings are included in the scene the
Utility display HA page settings are also stored. If head
amplifier settings are not included in the scene, the HA
page settings are stored as head amplifier startup
settings.
NOTE
Any parameter values changed by GPI/MIDI controllers
will be lost if the power is turned off or if scenes are
changed. To preserve the changed values, store the
scene data.
40
DME64N/DME24N Owner’s Manual
Select the desired monitor source from the
list.
List selections are made as described in the “List
Parameters” section on page 38.
The following five position types can be selected:
1 Slot input/output terminal
2 CASCADE input/output terminal (DME64N only)
3 IN terminal (DME24N only)
4 OUT terminal (DME24N only)
5 User Defined
By connecting 1 through 4 in DME Designer, you
will be able to select the input/output terminal.
You will be able to select 5 by editing the Monitoring
Point List in DME Designer.
Spectrum Display
3.
Select the desired monitor point from the
list.
Spectrum Display
The audio signal from the selected monitoring point
will be output via the PHONES jack and the
[MONITOR] indicator lights up.
The monitor functions also provide spectrum analyzer
type level display of the signal at the selected monitor
point.
NOTE
NOTE
Press the [CANCEL] button to move back to the previous
edit display.
Spectrum display is not available on the ICP1 control
panel.
NOTE
When the monitoring function is set to ON
([MONITOR] indicator lit steadily), you can turn it
OFF by pressing the [MONITOR] button.
Probe Monitor Functions
The Probe Monitor function allows monitoring points to
be selected from the DME Designer application. For
details, see the “DME Designer Owner’s Manual.”
When the Probe Monitor function is used the monitoring
point will change and the [MONITOR] indicator will flash.
Procedure
1.
Select the monitor point for which you want
to see a spectrum display from the list.
2.
Press the [ENTER] button.
A spectrum display of the audio signal at the
selected monitor point will appear.
1
4
3
NOTE
The monitoring point selected in the DME64N/24N is
disabled.
2
1 Frequency
These are the separate frequency bands displayed.
2 Band Output Level
Signal level is displayed independently in 31 separate
frequency bands. Output level is displayed in 12 steps.
3 Peak Hold
Panel Operation and Displays
When the peak hold function is ON, peak levels since
the current monitor point was selected are held
indefinitely. Peak levels are cleared after one second
when peak hold is OFF.
To turn the peak hold function ON or OFF, move the
cursor to the PEAK HOLD ON/OFF setting and press the
[ENTER] button to alternately turn it ON or OFF.
4 L/R Select
Indicates when the spectrum display is for the left or
right channel. The same spectrum display will be shown
for the L and R channels of all monitor points other than
user-defined points specified via the DME Designer
application.
To switch between the L and R displays move the cursor
to the CHANNEL L/R setting and press the [ENTER]
button to alternately select L or R.
NOTE
The fall rate of the meters can be set up via the Utility
display “Disp” page.
DME64N/DME24N Owner’s Manual
41
Level Meter Display
Level Meter Display
Individually displays the input/output level for each
channel.
NOTE
Level display is not available on the ICP1 control panel.
1.
Make sure that the Main display is showing.
If the Main display is not showing, press the
[CANCEL] to return.
2.
Initializing the DME64N/
DME24N
The DME64N/DME24N and ICP1 internal memories can
be initialized as follows.
Begin with the power turned off. Turn the power on while
holding the [SCENE] and [ENTER] buttons, and continue
to hold those buttons until the Yamaha logo appears.
The initialization screen will appear, allowing you to
choose one of the following three options.
Press the [UTILITY] button.
The level meter display will appear.
1
SCENE
4
HOME
UTILITY
LEVEL
MUTE
CANCEL
ENTER
1.Holding down the [SCENE] and [ENTER] buttons
3
2.Press the
[POWER]
button
Plug the PA-300 AC adaptor while
holding down the [SCENE] and
[ENTER] buttons
2
1 Level Display Slot
Select from [SLOT1] ~ [SLOT4], [AD/DA],
[CASCADE IN] or [CASCADE OUT].
NOTE
[SLOT2] ~ [SLOT4] and [CASCADE IN], [CASCADE
OUT] are only available on the DME64N, while [AD/DA]
is only available on the DME24N.
2 Channel Number
A maximum of 32 [CASCADE IN]/[CASCADE OUT]
channels can be displayed, while for other channels a
maximum of 16 can be displayed.
3 Input/Output Level Display
Shows the levels at the individual inputs and outputs.
4 Peak Hold
Panel Operation and Displays
When the peak hold function is set to ON, peak levels
are held indefinitely.
Peak levels are cleared after one second when peak
hold is set to OFF.
To turn the peak hold function ON or OFF, move the
cursor to the PEAK HOLD ON/OFF setting and press the
[ENTER] button to alternately turn it ON or OFF.
42
DME64N/DME24N Owner’s Manual
01.Initialize DME:
All scenes, preset parameter settings and WAVE files
except components and files saved via the File Storage
function will be deleted. All UTILITY settings are reset to
their default values.
02.Delete All Data:
All internally-stored components, scenes, preset
parameters, wave files, and files stored using the File
Storage function are erased. All UTILITY settings are
reset to their default values. Use this problem when a
problem occurs with the data stored in the device. After
initialization, make sure to update the firmware and the
components from the DME Designer application.
Refer to the DME Designer Owner’s Manual for details.
03. ==> Exit Diag Mode:
Exits from the initialization screen and restarts the unit.
Do not turn off the power during initialization. Doing so
can damage the device.
Utility Displays
Utility Displays
Most basic DME64N/24N functions can be accessed via the Utility Display.
Items accessible via the Utility display
Page
Item
Info
Description
Manual Page
Current status and settings for the devices basic parameters.
Label
Page 45
Name display.
Version
The device’s current version number.
Date
Current status and setup for the internal calendar/clock.
Battery
Shows the status of the internal battery.
MASTER/SLAVE
Displays current status and determines whether the device is device group master or not.
IP Adr.
Current status and setup for the device’s IP address.
Master ID
Displays and sets the device group master host address.
Net
Current status and settings for the Ethernet network.
Link Mode
Current status and setup for the [NETWORK] connector.
MAC Adr.
Displays the device’s MAC address.
Disp
Page 46
Current status and setup for the display mode, etc.
Page 46
LCD Contrast
Current status and setup for display panel contrast.
LCD Backlight
Current status and setup for the display panel backlight.
Meter Fall Time
Current status and setup for meter fall time.
Utility
Current status and setup for the Utility display settings.
Panel Lock Boot
Current status and setup for the DME64N/24N’s power-on panel lock status.
Lock
Current status and setup for panel lock and related functions.
Panel Lock Target
Current status and setup for the panel lock target.
User Defined Lock
Panel lock and setup for each page of User Defined Button.
Scene Store
Current status and setup for scene store accessibility.
Misc
Page 47
Current status and setup for settings not included in other pages.
Page 48
Last Mem. Resume Indicates and determines whether the previous memory contents will be retained when the
unit is restarted.
Current status and setup whether an event schedule setup in the DME Designer will be
executed or not.
Rmt Ctrl
Displays/sets the connector and connection type to be used for DME remote control
protocol communication.
Int HA Ctrl
Displays/sets the connector to be used for internal head amp control.
Ext HA Ctrl
Displays/sets the type of connection to be used for external head amp control.
COM
Displays/sets the type of connection to be used for DME protocol communication.
MIDI
Current status and setup for MIDI functions.
Page 49
Port
Current status and setup of the MIDI port.
Protocol
Displays/sets the protocol to be used for communication with devices connected via MIDI.
CH
Current status and setup for the MIDI transmit and receive channels.
Program Change
Current status and setup for program change transmission/reception, omni on, and echo
on/off.
Control Change
Current status and setup for control change transmission/reception, omni on, and echo
on/off.
Param Change
Current status and setup for parameter change transmission/reception, omni on, and echo
on/off.
Fs
Displays the word clock frequency.
Int
Current status of the internal word clock.
Current status and selection of the DME64N/24N word clock.
WCLK
Page 48
Panel Operation and Displays
Remote
Event Scheduler
Page 50
WCIN
Current status of the word clock received at the [WORD CLOCK IN] connector.
Cascade
Current status of the word clock received via the [CASCADE IN] and [CASCADE OUT]
connectors.
SLOT1-4
Current status of the word clock received via cards plugged in to the I/O card slots.
DME64N/DME24N Owner’s Manual
43
Utility Displays
Page
Item
Displays info about an I/O card installed in a DME64N/24N I/O slot.
Slot
Card name
Displays the name of the installed card.
(no title)
Resets the installed card.
Format
Reset
Resets the GPI calibration.
Max
Sets the maximum calibration value.
Min
Sets the minimum calibration value.
(no title)
HA
Current status and setup for head amplifier type.
WCLK
Current status and setup for the word clock used by the head amplifier(s).
(no title)
Displays the audio format 88.2/96 kHz.
Gain
Current status and setup for individual head amplifier channel gain.
+48V
Current status and setup for individual head amplifier channel phantom power supply (+48V
ON/OFF).
(no title)
Displays current status of the master phantom power switch.
HPF
Current status and setup for individual head amplifier channel high-pass filter on/off.
Frq
Current status and setup for individual head amplifier channel high-pass filter frequency.
CASCAD
(DME64N Head Margin
only)
Displays current status for the [CASCADE] connectors.
Page 51
Page 52
Page 53
Displays current status for the head margin of the audio signal handled via the [CASCADE]
connectors.
Unit No.
Displays how many devices the unit is from the beginning of the cascade chain.
Mixer I/O
Displays current status for the channels to be used for audio signals cascaded to a mixer.
Mode
Current status and setup for the thru connection.
Panel Operation and Displays
44
Page 51
Current calibration status.
Current status and setup for the internal and connected external head amplifiers.
HA
Manual Page
Displays the audio format – 88.2 or 96 kHz.
GPI connector calibration and status display.
GPI
Check
Description
DME64N/DME24N Owner’s Manual
Page 54
Utility Displays
2 Program Version
Utility Display Operation
This is the current firmware version number.
The general procedure for operating the Utility displays
is outlined below.
1.
Press the [UTILITY] button for longer than
2 seconds from the Main display to go to
the Utility display.
2.
Press the [UTILITY] button as many times
as necessary until the desired parameter
page appears.
3 Date
Shows the currently set date and time. The internal clock
and calendar can be set here.
Edit using the “Numeric Parameters” editing procedure
described on page 36.
NOTE
“Device group slave” cannot be used to set this
parameter.
Date/Time Parameter Edit Dialog
NOTE
Press the [CANCEL] button to display the pages in
reverse order.
3.
Use the cursor buttons – [ E ] [ ] [ ] [ F ]
– to select the parameter you want to edit.
NOTE
On the ICP1 the function buttons are used in place of the
cursor buttons as follows:
[F1] button: Left
[F2] button: Up
[F3] button: Right
[F5] button: Down
4.
Press the [ENTER] button.
This either confirms a selection or edit, or calls the
appropriate parameter edit page.
Info Page
Day - Month - Year
Hour : Minute : Second
4 Battery
Shows the status of the internal battery. “Low Battery”
will appear when the battery needs to be replaced, and
“No Battery” will appear when no battery is present in
the device.
5 Daylight Saving Time
If you enable daylight saving time, the display will
indicate “DST.”
You can enable daylight saving time using DME
Designer from a connected computer.
NOTE
Daylight saving time cannot be set on the DME64N/24N
itself.
1
2
5
Panel Operation and Displays
3
4
NOTE
The date and time (3) and the internal battery status
(4) are not shown on the ICP1 control panel display.
1 Label
Shows the name. The name can be changed via the
DME Designer application running on a computer
connected to the unit.
NOTE
The name can not be changed from the DME64N/24N
controls.
DME64N/DME24N Owner’s Manual
45
Utility Displays
Network Settings (Net) Page
Shows the Ethernet network address and other
parameters.
1
2
3
4
5
NOTE
If the IP address of the DME device is changed after the
device has been synchronized with DME Designer, it will
be necessary to re-transfer the configuration data by
performing a “Full Resync” operation.
Refer to the “Online” section in Chapter 2 of the DME
Designer Owner’s Manual for details about the “Full
Resync” operation.
3 Master ID
Displays and sets the device group master host
address.
1 Master/Slave
Indicates whether or not the device is functioning as the
device group master: “Master” or “Slave.”
Master: the device is the device group master.
Slave: the device is a device group slave.
Edit using the “List Parameters” editing procedure
described on page 38.
NOTE
Device group status of ICP1 is fixed to “Slave.” This
cannot be changed.
NOTE
Make sure that one device group master is assigned for
each device group.
If no device group master is assigned, no scene
information will appear on the display and scene-related
control will not be possible. Mute operations will also not
be possible.
NOTE
This is not displayed on the device group master device.
4 Link Mode
Shows the status of the [NETWORK] connector. The
[NETWORK] connector can be set to operate in
“10Base-T” or “100Base-TX” mode.
10Base-T: The [NETWORK] connector is
compatible with 10Base-T operation.
100Base-TX: The 100Base-Tx: [NETWORK]
terminal operates as 100Base-TX if possible. If the
network environment does not support 100BaseTX, it operates as 10Base-T.
Edit using the “List Parameters” editing procedure
described on page 38.
5 MAC Adr.
This is the device’s MAC (Media Access Control)
address.
2 IP Adr.
This is the device’s IP address.
Edit using the “Numeric Parameters” editing procedure
described on page 36.
NOTE
The MAC address is also known as the Ethernet
address, and is an independent address assigned to all
Ethernet devices. No two devices anywhere in the world
can have the same address.
Panel Operation and Displays
Display Setup (Disp) Page
Network Address
Host Address
NOTE
The network addresses of devices in the same device
group must be the same.
Provides access to a number of display parameters.
NOTE
The meter fall time (3) is not shown on the ICP1 control
panel display.
NOTE
Device group master's IP address can be changed via
the DME Designer application running on a computer
connected to the unit.
1
2
3
46
DME64N/DME24N Owner’s Manual
Utility Displays
1 LCD Contrast
The current LCD contrast setting. This parameter can be
adjusted from 0% through 100%.
Edit using the “Numeric Parameters” editing procedure
described on page 36.
2 LCD Backlight
Specifies LCD backlight operation. Two settings are
available: “ON,” and “OFF.”
ON: The display is continuously lit.
OFF: The display lights when a control is operated,
and will go out 10 seconds after panel operation
ceases.
Pressing the [ENTER] button alternately selects “ON”
and “OFF”.
Use the [ E ] and [ F ] buttons to position the cursor,
and the dial to enter the desired character at the cursor
location. When all of the password’s characters have
been entered as required press the [ENTER] button.
The password will also be required when switching from
the “Unlock” mode to the “Lock” mode.
NOTE
Password security and management is very important!
If you forget your password the unit cannot be operated!
If you forget your password contact the system
administrator.
If the password become unrecoverable for some reason
and you need to unlock the system, please contact your
Yamaha representative.
2 Panel Lock Boot
3 Meter Fall Time
Determines the fall time of the level meters – “Fast” or
“Slow.”
Fast: The meters rapidly follow changes in the
signal level.
Slow: The meters fall slower than the actual
changes in the signal level, allowing easier reading
in some cases.
Edit using the “List Parameters” editing procedure
described on page 38.
Security Setup (Lock) Page
Panel lock and related settings.
Determines whether or not panel lock will be on when
power to the device is turned on. This parameter can be
set to “Unlock” or “Lock.”
Unlock: Panel lock is OFF when power to the
device is turned on.
Lock: Panel lock is ON when power to the device is
turned on.
3 Panel Lock Target
Determines the controls (control functions) to be affected
by panel lock. The available settings are “Key Only” and
“Key+GPI.”
Key Only: Panel lock only affects the panel
buttons.
Key+GPI: Panel lock applies to the panel buttons
as well as GPI control input.
NOTE
1
2
3
4
See page 36 for details on how to use the Panel lock
feature.
NOTE
This parameter is displayed, but cannot be changed on
the ICP1 display.
1 Utility
When “Lock” is selected a password entry window will
appear when the [UTILITY] button is pressed to access
the utility pages.
4 User Defined Lock
Sets the lock status individually for each of the four User
Defined Button pages.
ON: The corresponding User Defined Button will
not appear on the display.
OFF: The corresponding User Defined Button will
appear on the display.
Panel Operation and Displays
The lock status for the Utility display settings. This
parameter can be set to “Unlock” or “Lock.”
Unlock: The Utility display can be accessed
without a password.
Lock: A password must be entered to access the
Utility display.
To change the settings use the [ E ] and [ F ] buttons to
move the cursor to the setting for the desired page, the
press the [ENTER] button to alternately turn the setting
“ON” and “OFF.”
NOTE
The User Defined Button are accessed as described in
the “Parameter Edit Display” section on page 36.
DME64N/DME24N Owner’s Manual
47
Utility Displays
Miscellaneous Setup (Misc) Page
This page includes parameters not available in any other
page.
1
2
3
3 Event Scheduler
Determines whether an event schedule setup in the DME
Designer will be executed or not, and displays the
current status. This parameter can be set to “ON” or
“OFF.”
ON: The event will be executed.
OFF: The event schedule will not be executed.
Edit using the “List Parameters” editing procedure
described on page 38.
NOTE
This parameter can be changed from the device group
master only.
1 Scene Store
Determines whether or not scene store operations are
allowed. This parameter can be set to “Enable” or
“Disable.”
Enable: Scene store operations are allowed.
Disable: Scene store operations are prohibited.
Edit using the “List Parameters” editing procedure
described on page 38.
NOTE
1
2
3
4
This item cannot be set if Internal HA Ctrl is set to
Remote.
NOTE
NOTE
This page will not appear on the ICP1 display.
This setting applies to individual devices only. Even if
one DME64N/24N unit is set to “Disable,” scene store
operations will be possible via another DME64N/24N in
the same device group that is set to “Enable.”
2 Last Mem. Resume
This parameter displays and determines whether the
DME64N/DME24N will recall the current scene when
started up, or whether the memory contents at the time
the unit was turned off will be recalled. The possible
settings are “ON” or “OFF”.
ON: The memory contents at the time the unit
was turned off will be recalled at startup.
OFF: The current scene will be recalled at
startup.
Panel Operation and Displays
NOTE
This parameter can be changed from the device group
master only.
CAUTION
48
Remote Control Setup (Remote) Page
If “Last Mem. Resume” is set to ON, the unit will
back up data to the internal memory periodically.
In this case, do not turn off the power to the unit
within five (5) seconds after you operate any
parameters.
DME64N/DME24N Owner’s Manual
1 Rmt Ctrl (Remote Control)
Displays/sets the connector and connection type to be
used for DME remote control protocol* communication. If
the selected terminal was previously assigned to a
different function, a confirmation dialog will appear. Edit
using the “List Parameters” editing procedure described
on page 38.
OFF: Select “OFF” when this function is not to be
used.
Remote (232C): External controllers (AMX,
Crestron, etc.) control the DME64N/24N via the
[REMOTE] connector using an RS-232C
connection.
Remote (422): External controllers (AMX, Crestron,
etc.) control the DME64N/24N via the [REMOTE]
connector using an RS-422 connection.
Network: This setting allows the DME64N/24N to
be controlled via the [NETWORK] terminal. When
“Network” is selected it is also possible to select the
port number to be used.
Utility Displays
Displays/sets the connector to be used for internal head
amp control. From a single digital mixer, you can control
the internal head amps of multiple DME series units
within the device group. Set this parameter only on the
DME series units that is connected directly to the digital
mixer, and turn in “OFF” for other units. Edit using the
“List Parameters” editing procedure described on page
38.
OFF: Select “OFF” when this function is not to be
used.
Remote (422): Allows a digital mixer to control the
internal head amps via RS-422 protocol.
Slot1 [Slot1 ~ Slot4 (DME64N)]: Allows a digital
mixer to control the internal head amps via the
specified expansion slot.
3 Ext HA Ctrl (External head amp control)
Displays/sets the type of connection to be used for
external head amp control.
OFF: Select “OFF” when this function is not to be
used.
Remote (422): Allows remote head amp control.
Always use this setting when a remote head amp
unit (AD8HR, AD824) is connected. Also, don’t
change the setting while a remote head amp is
connected. Doing so can damage the unit.
4 COM
Displays/sets the type of connection to be used for DME
communication Protocol. This is a Yamaha maintenance
function. Normally, set this to “OFF”.
MIDI Setup (MIDI) Page
3
1
2
4
5
6
NOTE
This page will not appear on the ICP1 display.
1 Port (MIDI port)
Sets/displays the port to be used for MIDI
communication. The available settings are: OFF,
Remote(232C), Remote(422), MIDI, USB-1, USB-2,
SLOT-1, SLOT-2, SLOT-3, and SLOT-4.
OFF: Select “OFF” when this function is not to be
used.
Remote (232C): MIDI data will be received via the
[REMOTE] connector using an RS-232C
connection.
Remote (422): MIDI data will be received via the
[REMOTE] connector using an RS-422 connection.
MIDI: The MIDI connector is the currently active
MIDI port.
USB-1, USB-2: The corresponding USB port is
selected for MIDI input.
Slot1 [Slot1 ~ Slot4 (DME64N)]: A card installed
in the corresponding I/O slot is currently selected
for MIDI input.
Edit using the “List Parameters” editing procedure
described on page 38.
NOTE
When the DME64N/24N is functioning as the device
group master and is connected to a computer running
the DME Designer application via USB, the MIDI port
being used by the DME Designer will not be available.
Panel Operation and Displays
2 Int HA Ctrl (Internal head amp control)
DME64N/DME24N Owner’s Manual
49
Utility Displays
2 Protocol (MIDI Protocol Setup)
Displays/sets the protocol to be used for communication
with devices connected via MIDI. The available settings
are: MIDI, DAW(Type1), and DAW(Type2).
MIDI: Use this setting when any MIDI device other
than a general-purpose ProTools controller (HUI
protocol) or general-purpose Logic or Cubase
controller (Mackie control protocol) is to be
connected.
DAW (Type1): Use this setting when a generalpurpose ProTools controller (HUI protocol) is to be
connected.
DAW (Type2): Use this setting when a generalpurpose Logic or Cubase controller (Mackie control
protocol) is to be connected.
Edit using the “List Parameters” editing procedure
described on page 38.
Refer to the DAW controller owner’s manual as well as
the DME Designer manual for setup details.
Word Clock Setup (WCLK) Page
Shows the status of incoming word clock signals, and
allows setup of the DME64N/24N master word clock.
NOTE
This page will not be displayed on the ICP1.
1
2
3
4
Master Clock Selection Procedure
1.
Use the cursor [ E ], [ ], [ ], [ F ], buttons
to select one of the square blocks
representing the available master clock
sources.
2.
Press the [ENTER] button to select the
master clock.
NOTE
“DAW” stands for “Digital Audio Workstation.” ProTools,
Logic, and Cubase are DAW applications, and this
parameter provides direct compatibility with a number of
physical controls surfaces that are available for use with
these DAW software packages.
The following parameters are available when the
Protocol parameter is set to MIDI.
3 CH
Specifies the device’s MIDI transmit and receive channel:
1 ~ 16.
Edit using the “List Parameters” editing procedure
described on page 38.
1 Fs
The current sampling frequency of the master word
clock. The value shown here is determined by the
system’s master word clock signal. To select the word
clock to be used as the master, move the cursor to the
appropriate word clock indication in this display – the
[WORD CLOCK IN] clock, the cascade clock, or a slot
clock, for example – and press the [ENTER] button.
2 Int
Panel Operation and Displays
4 Program Change
Sets the frequency of the internal word clock – 44.1 kHz,
48 kHz, 88.2 kHz, or 96 kHz.
Turns transmission and reception, the omni mode, and
echo ON or OFF for MIDI program change messages.
Move the cursor to the required parameter, then press
the [ENTER] button to alternately turn ON and OFF.
3 WCIN
5 Control Change
4 Cascade
Turns transmission and reception, the omni mode, and
echo ON or OFF for MIDI control change messages.
Move the cursor to the required parameter, then press
the [ENTER] button to alternately turn ON and OFF.
6 Parameter Change
Turns transmission and reception, and echo ON or OFF
for MIDI parameter change messages.
Move the cursor to the required parameter, then press
the [ENTER] button to alternately turn ON and OFF.
50
5
DME64N/DME24N Owner’s Manual
Shows the status of the word clock signal at the [WORD
CLOCK IN] connector.
Shows the status of the word clock signal at the
[CASCADE IN] and [CASCADE OUT] connectors.
Utility Displays
5 SLOT1~4
Shows the status of the word clock signal input via I/O
cards installed in the I/O slots.
GPI Setup (GPI) Page
Input calibration parameters for the [GPI] connector.
The Status Icons
A word clock signal is present, and this signal can be
selected as the DME64N/24N word clock.
NOTE
This page will not appear on the ICP1 display.
No word clock signal (cannot be selected as the master
clock).
A word clock signal is present, but is not in sync with
the master word clock.
Currently selected as the DME64N/24N word clock.
Currently selected as the DME64N/24N word clock, but
the clock signal is not useable.
Inactive slot channel, or no I/O card is present in the
slot.
1
2
4
3
1 Reset
Slot Information (Slot) Page
Displays the name of the card installed in an I/O card
slot. Some cards can also be reset via this page.
Resets GPI calibration.
To reset the calibration, use the [ E ] [ ] [ ] [ F ]
buttons to select ALL to reset all inputs, or select an
individual input from 1 to 16 to be reset, then press the
[ENTER] button.
2 MAX
Sets the maximum calibration value.
To set the MAX value, use the [ E ] [ ] [ ] [ F ]
buttons to select ALL to set all inputs, or select an
individual input from 1 to 16 to be set, then press the
[ENTER] button to set the MAX value to the current input
voltage.
2
1
3
NOTE
3 MIN
The name of the installed card appears here.
Sets the minimum calibration value.
To set the MIN value, use the [ E ] [ ] [ ] [ F ]
buttons to select ALL to set all inputs, or select an
individual input from 1 to 16 to be set, then press the
[ENTER] button to set the MIN value to the current input
voltage.
2 Reset
4 Calibration Info
Resets the installed card.
Shows the calibration settings as well as the current
input voltage.
This page will not appear on the ICP1 display.
1 Card Name
3 Format
Panel Operation and Displays
Displays the 88.2/96 kHz audio signal transfer mode.
The input setting is on the left and the output setting is
on the right.
No Display (Default): 44.1/48 kHz audio signal
transfer.
SP (Double Speed): An 88.2/96 kHz capable card
is installed, allowing direct transfer at 88.2 or 96
kHz.
CH (Double Channel): A 44.1/48 kHz card is
installed, and 88.2 or 96 kHz audio is transferred by
using two 44.1/48 kHz channels to transfer each
channel of 88.2/96 kHz audio. The number of audio
channels that can be handled in this mode is half
the number of channels normally handled by the
card.
DME64N/DME24N Owner’s Manual
51
Utility Displays
2 WCLK (AD8HR/AD824 only)
Head Amplifier Setup (HA) Page
Provides access to the head amplifier settings. Refer to
“REMOTE Connection” on page 28 for head amplifier
control signal connection.
NOTE
This page will not appear on the ICP1 display.
NOTE
Some scenes include head amplifier settings. In such
cases, the HA page settings will be saved along with the
scene when it is stored.
Internal Head Amplifier (DME24N only)
1
4
5
AD8HR
2
1
6
8
4
7
3
2
1 HA
Panel Operation and Displays
Specifies the type of head amplifier to be set up. The
available options are AD8HR, AD824, and Built-in HA
(DME24N only). When the AD8HR and AD824 are
selected, a number indicating the connection order will
also appear.
Edit using the “List Parameters” editing procedure
described on page 38.
DME64N/DME24N Owner’s Manual
Available settings of the AD824 are “SLOT,” “BNC,”
“INT44.1K,” and “INT48K.”
SLOT A: Sets the word clock signal input via I/O
cards installed in the I/O slots as the master clock
of the AD824.
BNC: Sets the word clock signal at the BNC
connector as the master clock of the AD824.
INT44.1K: Sets the 44.1 kHz internal word clock as
the master clock of the AD824.
INT48K: Sets the 48 kHz internal word clock as the
master clock of the AD824.
3 Format (AD8HR only)
4
5
52
Available settings of the AD8HR are “D OUT A,” “WCLK
IN,” “INT44.1K,” “INT48K,” “INT88.2K,” and “INT96K.”
D OUT A: Sets the word clock signal at the digital
input as the master clock of the AD8HR.
WCLK IN: Sets the word clock signal at BNC
connector as the master clock of the AD8HR.
INT44.1K: Sets the 44.1 kHz internal word clock as
the master clock of the AD8HR.
INT48K: Sets the 48 kHz internal word clock as the
master clock of the AD8HR.
INT88.2K: Sets the 88.2 kHz internal word clock as
the master clock of the AD8HR.
INT96K: Sets the 96 kHz internal word clock as the
master clock of the AD8HR.
5
AD824
1
Specifies the word clock signal to be used by the head
amplifier(s).
Displays the 88.2/96 kHz audio signal transfer mode.
The input setting is on the left and the output setting is
on the right.
No Display (default): 44.1/48 kHz audio signal
transfer.
SP (Double Speed): Allows direct transfer at 88.2
or 96 kHz.
CH (Double Channel): 88.2 or 96 kHz audio is
transferred by using two 44.1/48 kHz channels to
transfer each audio channel of 88.2 and 96 kHz
respectively. The number of audio channels that
can be handled in this mode is half the number of
channels normally handled by the AD8HR.
4 Gain
Individually sets the gain of each head amplifier channel.
Edit using the “Numeric Parameters” editing procedure
described on page 36.
Utility Displays
NOTE
The gain of the DME24N internal head amplifiers can be
adjusted from +10 dB to –60 dB in 1-dB increments. The
internal circuitry switches at about the –45-dB point, and
the signal is automatically muted at that point to prevent
noise.
The AD8HR gain can be adjusted from +10 dB to –62 dB
in 1-dB steps, and the AD824 gain can be adjusted from
+10 dB to –62 dB in 6-dB steps.
The PAD will be internally switched on or off when the
gain of the DME24N built-in head amplifier is adjusted
between -8 dB and -7 dB. Keep in mind that noise may
be generated if there is a difference between the Hot
and Cold output impedance of the external device
connected to the IN connector when using phantom
power.
Cascade Setup (CASCAD) Page
Shows the status of the [CASCADE] connectors. Refer to
“CASCADE Connection” on page 31 for connection
details.
Settings are made from the DME Designer application
running on the connected computer.
NOTE
This page only appears on the DME64N.
1
2
3
5 +48V
Individually turns phantom power ON or OFF for each
head amplifier channel.
Use the [ E ] and [ F ] buttons to position the cursor at
the desired channel, then press the [ENTER] button to
alternately turn phantom power for that channel ON and
OFF.
CAUTION
• Always turn the phantom power off when it is not
needed.
• When turning phantom power ON, make sure
that no equipment other than phantom-powered
devices such condenser microphones are
connected to the [IN] connectors (DME24N only).
Applying phantom power to a device that does
not require phantom power can damage the
device.
• Do not connect or disconnect a device to a [IN]
connector (DME24N only) while phantom power
is applied. Doing so can damage the connected
device and/or the unit itself.
• To prevent speaker and possible hearing
damage, be sure to turn power amplifiers OFF
when turning phantom power ON or OFF. It is
also a good idea to turn the output level all the
way down (page 39).
1 Head Margin
Displays the head margin for cascade connection.
18dB: Use this setting when cascading DME64N
units or when connecting to a mixer’s normal
cascade bus.
0dB: Use this setting when connecting to a PM5D
in situations in which the PM5D SLOT OUT port
signal is being output via the CASCADE OUT
terminal.
NOTE
The Head Margin setting only applies when connected
to a mixer. When the DME64N is connected to another
DME64N unit, head margin is fixed at 18 dB.
2 Unit No
Shows how many devices the unit is from the beginning
of the cascade chain.
OUT
6 Phantom Master Switch (AD8HR only)
IN
OUT
IN
OUT
IN
Displays overall phantom power ON or OFF.
Individually turns the high-pass filter for each AD8HR
head amplifier channel ON or OFF. This parameter is
only available for the AD8HR head amplifier. Use the [ E
] and [ F ] buttons to select a channel, then press the
[ENTER] button to turn the HPF for that channel ON or
OFF.
8 High-pass Filter Frequency (Frq)
(AD8HR only)
Individually sets the high-pass filter frequency for each
AD8HR head amplifier channel. This parameter is only
available for the AD8HR head amplifier.
Edit using the “Numeric Parameters” editing procedure
described on page 36.
DME64N
Unit No = 01
DME64N
Unit No = 02
DME64N
Unit No = 03
Panel Operation and Displays
PM5D
7 High-pass Filter (HPF) (AD8HR only)
3 Mixer I/O
Displays whether the cascade signal is bus shared or
not.
: A DME64N connected directly to the mixer is
connected to a second DME64N on this
unidirectional channel.
Input on the same channel from other DME64N
units will be independent.
: This channel is being used for bidirectional bus
shared connection between DME64N units. Input
on the same channel from other DME64N units will
be summed.
DME64N/DME24N Owner’s Manual
53
Utility Displays
NOTE
Make sure that the Mixer I/O setting is the same for all
cascaded DME64N/24N units.
Check Page
Even in an environment with no computer, you can check
the connections without using DME Designer by directly
connecting the DME64N/24N input/output.
The meter does not operate during a connection check.
MODE: OFF
Makes connections in the configuration used in the
current scene.
This is set to OFF when the unit is started.
MODE: Thru
Directly connects the Input and Output of each slot oneto-one for each channel.
When input-only or output-only cards like AD or DA
cards are inserted in the slots, you cannot perform
checks in this mode.
In the DME24N, the internal AD and internal DA are
directly connected on each channel.
Panel Operation and Displays
MODE: Summing
Sums all input signals coming from Inputs (-12dB),
without regard to device or card type, and outputs it
through all Outputs.
NOTE
This page will not appear on the ICP1 display.
54
DME64N/DME24N Owner’s Manual
Options
References
Options
The ICP1, CP4SW, CP1SF, and CP4SF controllers are available as options for remote external control of the DME series.
The ICP1 connects via Ethernet, while the CP4SW, CP1SF, and CP4SF connect via the GPI interface. For more
information on installing your Control Panel and connecting it to a DME series unit, refer to the owner’s manual that came
with the Control Panel. For more information on settings, refer to the DME Designer Owner’s Manual.
ICP1
This controller connects to a DME series unit via Ethernet. Like the DME series units, a unique IP address
must be assigned to each controller unit. Data is transmitted and received via Ethernet cables.
You can assign and control any function of all DME series units in the same device group via the controller.
Up to four parameter sets can be assigned to six function buttons (F1 – F6) located above and under the
LCD. You can control up to 24 parameters by selecting a display page using the [HOME] button.
CP4SW, CP4SF, and CP1SF
CONTROL PANEL
CP4SW
10
10
10
10
10
0
0
0
0
0
CONTROL PANEL
CONTROL PANEL
CP4SF
CP1SF
DME64N/DME24N Owner’s Manual
References
These controllers connect to DME series units via the [GPI] connectors. These controllers control only the
DME series units to which they are directly connected. The controller switches enable you to turn the parameter settings On and Off. The switch LEDs enable you to check the parameter status. The faders enable
you to control the parameter values.
55
Error Messages
Error Messages
Message
Meaning
Action
Error messages
References
Cannot Select
No selectable items are available in the scene or
monitoring point list display.
Make the appropriate settings via the DME Designer
application.
Component Corrupt
Update Firmware!
The component data is corrupt or can’t be found.
Restart after updating the component using DME
Designer. If the error indicators are still indicating the
error, execute the “Delete All Data” initialization. If the
problem persists, contact a Yamaha dealer.
Critical Battery
The internal battery is almost discharged. Your data may
be lost.
If you turn off power to the unit, the current settings may
be lost and reset to the default values. Stop operating the
unit, and contact a Yamaha dealer for battery
replacement.
Int.Data Corrupt
Data inside the internal flash memory has been erased.
Execute the “Delete All Data” initialization. If the problem
persists, contact a Yamaha dealer.
Invalid Password
An invalid password has been entered.
Enter the correct password. If you have lost or forgotten
your password, contact a Yamaha dealer.
Log Buffer Full
Saving is not possible, since the Event Log saving area is
full.
Use DME Designer to delete the log.
Low Battery
The backup battery voltage is low.
This does not affect the operation of the unit. However, if
you continue using the unit, the settings may be lost and
reset to the default values. Contact a Yamaha dealer for
battery replacement at your earliest convenience.
No Battery
The internal battery is completely discharged or not
installed.
If you turn off the power to the unit, the current settings
will be lost and reset to the default values. Stop operating
the unit, and contact a Yamaha dealer for battery
replacement.
Param Access Err
The current setting cannot be displayed because the
parameter you attempted to operate does not exist. It is
possible that the component is not operating normally.
Save the current settings using DME Designer, execute
the initialization (Delete All Data). If the problem persists,
contact a Yamaha dealer.
Param Set Err
The current setting cannot be changed because the
parameter you attempted to operate does not exist. It is
possible that the component is not operating normally.
Save the current settings using DME Designer, execute
the initialization (Delete All Data). If the problem persists,
contact a Yamaha dealer.
ResumeData Corrupt
Recall a Scene!
The data has been partially corrupted due to power
shutdown while writing to the internal memory. The
current settings have been lost.
Recall the scene again. If the problem persists, contact a
Yamaha dealer.
Resume Data Lost!
Recall a Scene!
Current setting has been lost.
Recall the scene again.
If the problem persists, contact a Yamaha dealer.
Saving Failed
A save operation has failed.
Stop using the device immediately and contact a
Yamaha dealer.
SDRAM Err
This could be due to a hardware malfunction.
Refer this problem to a Yamaha dealer.
Slots Overloaded
The current being used by all cards installed in I/O slots
exceeds the rated limit.
Make sure that the total current consumption of the cards
used does not exceed the limit.
Store Disable
The scene store parameter is set to “Disable.”
Set the scene store parameter to “Enable” via the Utility
display “Lock” page.
Storing Failed
Either the flash memory for storing data is full, or the file
system has been damaged.
Reduce the number of unused scenes. Alternatively,
delete the files saved via the File Storage function. If
deleting these items does not solve the problem, execute
the Delete All Data initialization. If the problem persists,
contact a Yamaha dealer.
Cable Disconnect
No network cable connected.
Make sure that a network cable is properly connected,
and that all network devices are functioning normally.
Cannot be assigned
No parameter assigned.
Cannot Store
The scene data is protected.
Status messages
56
DME64N/DME24N Owner’s Manual
—
Set the protect parameter to “OFF” via the DME Designer
application.
Error Messages
Meaning
Action
CAS. In Sync Err
The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE IN] connector.
Make sure that the DME64N/24N and the card or external
source supplying the word clock are set to use the same
word clock.
CAS. Out Sync Err
The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE OUT] connector.
Make sure that the DME64N/24N and the card or external
source supplying the word clock are set to use the same
word clock.
Connection to Master
DME is Lost
Communication with the master DME device has been
interrupted.
Check that all cables are properly connected, and than
network switches, routers, and related devices are
functioning properly.
Connection to Slave
SME is Lost
Communication with the slave DME device has been
interrupted.
Check that all cables are properly connected, and than
network switches, routers, and related devices are
functioning properly.
Download Success
The program has been successfully updated.
—
Downloading
Do not turn off
Program update in progress. Do NOT turn power off
while the unit displays this message.
—
DSP Power Shortage
Audio is not input or output and is muted due to
insufficient DSP resources.
This error sometimes occurs if you try to operate a
configuration at 96 kHz that has been created with a
word clock of 48 kHz. To operate a configuration at any
word clock setting, use DME Designer to create a
configuration with the word clock set to 96 kHz.
Duplicate IP Adr.
Duplicate IP addresses.
Change the IP addresses so that there are no duplicates.
Err: Wrong Device
Group Settings
The device group configuration set via DME Designer
does not match the actual configuration.
Use DME Designer to go off-line, create a configuration
that correctly matches the actual configuration, and then
go back on-line to synchronize the configuration.
Executing
A User Defined Button operation is in progress.
—
File Opening
Do not turn off
A file operation is in progress during which the computer
manipulates scene data. Do NOT turn power off while the
unit displays this message.
—
Illegal MAC Adr.
An illegal MAC address has been encountered.
This could be due to a hardware malfunction. Refer this
problem to a contact a Yamaha dealer.
Invalid IP Adr.
The network IP address is not appropriate.
Set an appropriate network IP address.
Network Busy
There is too much network traffic. Communication is not
possible.
Check the devices connected to the network. If there are
too many devices connected, reduce the number of
devices.
Network Error
One of the following errors has occurred on the network:
• A cable has been unplugged.
• The power to a network switch or router has been shut off.
• A cable is in an inappropriate state (e.g. a heavy object
has been placed on the cable, etc.). Static electricity
can also cause errors.
Locate and eliminate the cause of the error.
Network Setup
Preparing network connection.
No Current Scene
There is no data in the current scene.
Send appropriate scene data from a computer running
the DME Designer application.
No MAC Adr.
MAC address not specified.
This could be due to a hardware malfunction. Refer this
problem to a Yamaha dealer.
Panel Locked
Panel operation not allowed.
Press the [CANCEL] button for longer than 2 seconds to
disengage panel lock and allow panel operation.
Panel Unlocked
Panel lock has been disengaged. Panel operation is now
possible.
Recovering
Do not turn off
A program update attempt has failed, and the previous
program is currently being restored.
Saving HA Info
Do not turn off
Head amplifier info save in progress.
(Do not turn power off.)
—
Saving Setup Info
Do not turn off
Info set up via the Utility display (other than head
amplifier info) is being saved.
(Do not turn power off.)
—
—
—
References
Message
Do NOT turn power off while the unit is displaying this
message. If the update attempt repeatedly fails, there
may be a hardware malfunction. Refer this problem to a
Yamaha dealer.
DME64N/DME24N Owner’s Manual
57
Error Messages
Message
Meaning
Action
Scene Recalling
Do not turn off
Scene recall in progress. Do NOT turn power off while the
unit displays this message.
—
Scene Storing
Do not turn off
Scene store in progress. Do NOT turn power off while the
unit displays this message.
—
Searching for Master
DME Unit...
Currently searching for the master DME unit.
—
Searching for Slave
DME Unit...
Currently searching for the slave DME unit.
—
SLOT1 Sync Err
The DME64N/24N clock is not synchronized with the
clock of the card installed in I/O slot 1.
Make sure that the DME64N/24N and the card or external
source supplying the word clock are set to use the same
word clock.
SLOT2 Sync Err
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 2.
Make sure that the DME64N and the card or external
source supplying the word clock are set to use the same
word clock.
SLOT3 Sync Err
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 3.
Make sure that the DME64N and the card or external
source supplying the word clock are set to use the same
word clock.
SLOT4 Sync Err
The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 4.
Make sure that the DME64N and the card or external
source supplying the word clock are set to use the same
word clock.
Synchronizing
Do not turn off
Data is being received from the computer. Do NOT turn
power off while the unit displays this message.
—
Updating
Do not turn off
Data is being received from the computer. Do NOT turn
power off while the unit displays this message.
—
WCLK Unlocked
A usable word clock signal is not being received or
cannot be detected.
Recheck all word clock connections and internal
parameters.
WCLK In Sync Err
The DME64N/24N clock is not in sync with the clock
signal being received at the WORD CLOCK IN]
connector.
Make sure that the DME64N/24N and the card or external
source supplying the word clock are set to use the same
word clock.
References
58
DME64N/DME24N Owner’s Manual
Troubleshooting
The power won’t turn on, and the panel
indicators and LCD won’t light.
• Is the power cable properly connected?
• Is the POWER switch turned on?
• If neither of the above is the problem, contact your Yamaha service center or representative.
Cannot exchange data between the
DME64N/24N and the DME Designer.
• Are the network cables connected correctly?
• Has the USB-MIDI driver been properly installed?
• If you are using the [NETWORK] connector, has the DME-N Network Driver been properly set up?
• Has a MIDI port been properly assigned (page 49)?
• Are you using a version of DME Designer later than 3.8?
No sound input.
• Are the cables connected properly?
• Is an appropriate signal being received from the external device?
• Is the GAIN of the internal (DME24N) or external head amp set to an appropriate level?
No sound output.
• Are the cables connected properly?
• Make sure that the output level isn’t turned down (page 39).
• Is MUTE ON (page 39)?
• Have you used DME Designer to select a scene that does not output audio?
• Are you attempting to run a configuration that is not compatible with 96 kHz operation at 96 kHz?
MIDI messages aren’t transmitted or
received.
• Is power to the MIDI device(s) turned on?
• Are the MIDI ports properly set up (page 49)?
• Are the receive and transmit device channels set appropriately?
Scenes are not recalled when MIDI
program change messages are
received.
• Have the settings required to receive program change messages been properly made (page 49)?
• Use the DME Designer to set up the MIDI Program Change table as required.
Parameter control does not function
even when MIDI control change
messages are received.
• Make the settings required to allow control change reception.
• Use the DME Designer to set up the MIDI Control Change table as required.
Parameter control does not function
even when MIDI parameter change
messages are received.
• Have the settings required to receive parameter change messages been properly made (page
49)?
• Use the DME Designer to set up the MIDI Parameter Change table as required.
Slow data transfer.
• Set the LINK MODE to 100Base-TX (page 46).
The desired scene can’t be recalled.
• Write the require scene data from the DME Designer to the DME64N/24N.
Scenes are recalled unexpectedly.
• Is input being received from an external device or the DME Designer?
• Use the DME Designer to check the MIDI Program Change Table settings.
• Use the DME Designer to check the GPI input assignments.
• Use the DME Designer to check the Remote Control Setup List assignments.
Scenes can be recalled but not stored.
• Set scene store to “Enable” (page 48).
The 96kHz/88.2kHz/48kHz/44.1kHz
indicator flashes red.
• Select a different word clock source (page 50).
• If an external device is functioning as the word clock master, check that the cables are connected
properly.
Noise appears on the analog outputs
when an external device is the word
clock master and the word clock source
is switched.
• Reduce the power amp level to prevent speaker damage, or turn the DME64N/24N off before
switching clock sources.
Use Defined Button settings change
unexpectedly.
• Use the panel lock function (page 38) to prevent unwanted operation of the panel controls on
specific DME64N/24N or ICP1 units.
User Defined Button settings cannot be
changed.
• Use the DME Designer to make sure that multiple User Defined Buttons are not assigned to the
same parameter.
• Turn the User Defined Lock function off (page 38).
The panel controls cannot be operated.
• Is the panel lock function on (page 36)?
The Utility screen cannot be opened.
• Is the Utility screen lock function on (page 47)? If you have forgotten your password contact your
Yamaha service center or representative.
DME64N/DME24N Owner’s Manual
References
Troubleshooting
59
Specifications
Specifications
Specifications and descriptions in this owner’s manual are for information purposes only. Yamaha Corp. reserves the right to
change or modify products or specifications at any time without prior notice. Since specifications, equipment or options may not
be the same in every locale, please check with your Yamaha dealer.
Sampling Frequency
Internal
44.1kHz, 48kHz, 88.2kHz, 96kHz
External
Normal Rate: 39.69 – 50.88kHz
Double Rate: 79.39 – 101.76kHz
DME64N: 0.85 msec (Input of MY8-AD96 to Output of MY8-DA96)
DME24N: 0.5 msec ([IN] port to [OUT] port)
Signal Delay (Fs = 96kHz)
Memory
Configuration
16 (depends on size of data)
Scene
999 (depends on size of data)
Display
160 x 64 dot matrix LCD with backlight
Scene No.
7-segment LED x 3
Indicators
Wordclock
EXT.CLOCK, 96kHz, 88.2kHz, 48kHz, 44.1kHz
External Control
NETWORK, MIDI
Zone Configuration
MASTER
Analog
Input*1
Analog Output*1
SIGNAL x 8, PEAK x 8
SIGNAL x 8, PEAK x 8
Power Requirements
120V AC, 60Hz (USA, Canada)
230V AC, 50Hz (Europe)
100V AC, 50/60Hz (Japan)
Power Consumption
DME64N: 80W
DME24N: 75W
Dimensions (W x H x D)
DME64N: 480 x 145 x 411.5mm, 3U
DME24N: 480 x 101 x 411.5mm, 2U
Weight
DME64N: 9.5kg
DME24N: 8kg
Temperature Range
Free-Air operating
10 – 35 °C
Storage
-20 – 60 °C
AC Power Cord Length
2.5m
Supplied Accessories
AC power cord, Owner’s Manual, AC plug clamp, 16-pin Euroblock
plug x 2, 8-pin Euroblock plug x 4 (DME64N), 3-pin Euroblock plug x
16 (DME24N)
*1. Available on DME24N only
European models
Purchaser/User Information specified in EN55103-1 and EN55103-2.
Inrush Current: 39A
Conforms to Environments: E1, E2, E3 and E4
References
60
DME64N/DME24N Owner’s Manual
Input/Output Characteristics
Input/Output Characteristics
Gain
CH INPUT -60dB
1–8
+10dB
Actual
Load
Impedance
3kΩ
Input Level
Connector
Max.
before clip
For Use
With
Nominal
Nominal
50 – 600Ω
Mics &
600Ω
Lines
-60dBu
(0.775mV)
+10dBu
(2.451V)
Input
CH INPUT
1–8
DME24N ANALOG INPUT CHARACTERISTICS
Terminals
Gain Error @1kHz
-40dBu
(7.75mV)
+30dBu
(24.511V)
Internal
OSC
Input
CH INPUT
1–8
DME64N ANALOG OUTPUT CHARACTERISTICS
PHONES
15Ω
For Use
With
Nominal
8Ω
40Ω
Output Level
Max. before
clip
Nominal
75mW
65mW
150mW
150mW
Connector
DME24N ANALOG OUTPUT CHARACTERISTICS
Actual
Source
Impedance
CH OUTPUT 75Ω
1–8
PHONES
15Ω
For Use
With
Nominal
600Ω Lines
8Ω
40Ω
Output Level
Max. before
Nominal
clip
+4dBu
(1.23V)
75mW
65mW
+24dBu
(12.28)
150mW
150mW
CASCADE IN
–
24-bit
Level
RS422
Max. Units
6.0
6.0
2.0
dBu
dBu
dBu
Output
RL
Conditions
Min.
Typ.
Max. Units
0.1
%
0.05
%
0.1
%
Total Harmonic Distortion fs=96kHz
CH INPUT
1–8
Internal
OSC
Output
RL
Conditions
Min.
Typ.
CH OUTPUT 600Ω GAIN = -60dB
1–8
@20Hz – 20kHz
@+14dBu
GAIN = +10dB
@20Hz – 20kHz
@+14dBu
PHONES
8Ω
-30dBFS @1kHz,
phones level control:
max.
Input
Connector
Euroblock
CH INPUT
1–8
Stereo
Phone Jack
Max. Units
0.1
%
0.05
%
0.1
%
–
Output
RL
Conditions
Min.
CH OUTPUT 600Ω GAIN = -60dB
1–8
Master fader at
nominal level and
one Ch fader at
nominal level.
(Mixer mode)
600Ω GAIN = +10dB
Master fader at
nominal level and
one Ch fader at
nominal level.
(Mixer mode)
PHONES
8Ω
Residual output
noise, phones level
control: min.
Typ.
Max. Units
-128
EIN
-64
dBu
dBu
-82
dBu
-86
dBu
• Hum & Noise are measured with a 6dB/octave filter @12.7kHz;
equivalent to a 20kHz filter with infinite dB/octave attenuation.
DME64N DIGITAL INPUT CHARACTERISTICS
Format Data Length
Typ.
4.0
4.0
0.0
Hum & Noise EIN = Equivalent Input Noise
• 0dBu = 0.775 Vrms
• All AD converters (CH1-8) are 24-bit linear, 128 times oversampling.
• Stereo Phone Jack = unbalanced (Tip = LEFT, Ring = RIGHT, Sleeve =
GND)
Terminal
Min.
CH OUTPUT 600Ω GAIN = -60dB
1–8
@20Hz – 20kHz
@+14dBu
GAIN = +10dB
@20Hz – 20kHz
@+14dBu
PHONES
8Ω
-30dBFS @1kHz,
phones level control:
max.
Input
Stereo
Phone Jack
• 0dBu = 0.775 Vrms
• Stereo Phone Jack = unbalanced (Tip = LEFT, Ring = RIGHT, Sleeve =
GND)
Output
Terminals
Conditions
Total Harmonic Distortion fs = 48kHz
Internal
OSC
Actual
Source
Impedance
RL
Euroblock
• 0dBu = 0.775 Vrms
• All AD converters (CH1-8) are 24-bit linear, 128 times oversampling.
• +48V DC (phantom power) is supplied to CH INPUT (1-8) connectors via
each individual controlled switch.
Output
Terminals
Output
CH OUTPUT 600Ω GAIN = -60dB
2.0
1–8
GAIN = +10dB
2.0
PHONES
8Ω
-30dBFS @1kHz,
-2.0
phones level control:
max.
Connector
D-SUB Half Pitch connector 68P
(Female)
DME24N ELECTRICAL CHARACTERISTICS
Dynamic Range
Input
DME64N DIGITAL OUTPUT CHARACTERISTICS
Terminal
Format Data Length
CASCADE OUT –
24-bit
Level
RS422
CH INPUT
1–8
Connector
D-SUB Half Pitch connector 68P
(Female)
Output
RL
Conditions
Min.
CH OUTPUT 600Ω GAIN = +10dB
1–8
Typ.
Max. Units
106
dB
• Dynamic range are measured with a 6dB/octave filter @12.7kHz;
equivalent to a 20kHz filter with infinite dB/octave attenuation.
Crosstalk@1kHz
From/To
* CH INPUT 1-8 and CH OUTPUT 1-8 are provided on the DME24 only.
Frequency Response 20Hz – 20kHz, reference to the nominal output level
@1kHz
Input
CH INPUT
1–8
Internal
OSC
Output
RL
Conditions
CH OUTPUT 600Ω GAIN = -60dB
1–8
PHONES
8Ω
Min.
Typ.
Max. Units
-1.5
0.0
0.5
dB
-3.0
0.0
0.5
dB
CH N
To/From
CH (N-1) or
(N+1)
Conditions
Input
CH INPUT
1–8
Internal
OSC
Output
RL
Conditions
CH OUTPUT 600Ω GAIN = -60dB
1–8
PHONES
8Ω
Min.
Typ.
Typ.
Max. Units
-80
dB
Maximum Voltage Gain@1kHz
Input
CH INPUT
1–8
Output
RL
Conditions
Min.
CH OUTPUT 600Ω GAIN = -60dB
1–8
Typ.
Max. Units
64
dB
Phantom Voltage
Output
Frequency Response fs = 96kHz@20Hz – 40kHz, reference to the nominal
output level @1kHz
Min.
CH1 – 8, adjacent inputs
Conditions
CH INPUT
1–8
hot, cold: No load
Min.
46
Typ.
48
References
DME64N/24N ELECTRICAL CHARACTERISTICS
(Output impedance of signal generator: 150Ω)
Max. Units
50
V
Max. Units
-1.5
0.0
0.5
dB
-3.0
0.0
0.5
dB
PEAK/SIGNAL Indicator Level
Input
Output
Conditions
GAIN +10dB PEAK
red LED: ON
Min.
CH INPUT
1–8
–
25
–
GAIN +10dB SIGNAL green -12
LED: ON
CH OUTPUT PEAK red LED: ON
19
1–8
SIGNAL green LED: ON
-18
Typ.
Max. Units
27
29
dBu
-10
-8
dBu
21
-16
23
-14
dBu
dBu
DME64N/DME24N Owner’s Manual
61
Control I/O
Control I/O
Terminals
REMOTE
Format
Connector
-
RS232C
-
RS422
D-SUB Connector 9-pin (Male)
Baud Rate = 38,400 bps
Data = 8bit
Stop bit = 1bit
PARITY = NON
MIDI
IN/OUT/THRU
-
DIN Connector 5P
WORDCLOCK
IN/OUT
TTL/75Ω
BNC Connector
Ethernet
Ethernet
-
RJ-45
USB
USB
0 – 3.3V
USB Type B (Female)
GPI
IN
0 – 5V
Euroblock Connector
OUT
TTL
+V
5V
DME64N: 16-GPI inputs and 16-GPI outputs
DME24N: 8-GPI inputs and 8-GPI outputs
Outputs: Imax/pin = 16mA
Outputs: VH = 2.5V(min.), VL = 0.6V(max.)
References
62
Level
DME64N/DME24N Owner’s Manual
Connector Pin Assign
Connector Pin Assign
[CASCADE IN/OUT] Connectors (DME64N only)
CASCADE IN
Pin
No.
Signal
CASCADE OUT
Pin
No.
Signal
Pin
No.
Signal
Pin
No.
Signal
1
GND
35
GND
1
GND
35
GND
2
INPUT 1-2 (+)
36
INPUT 1-2 (-)
2
OUTPUT 1-2 (+)
36
OUTPUT 1-2 (-)
3
INPUT 3-4 (+)
37
INPUT 3-4 (-)
3
OUTPUT 3-4 (+)
37
OUTPUT 3-4 (-)
4
INPUT 5-6 (+)
38
INPUT 5-6 (-)
4
OUTPUT 5-6 (+)
38
OUTPUT 5-6 (-)
5
INPUT 7-8 (+)
39
INPUT 7-8 (-)
5
OUTPUT 7-8 (+)
39
OUTPUT 7-8 (-)
6
INPUT 9-10 (+)
40
INPUT 9-10 (-)
6
OUTPUT 9-10 (+)
40
OUTPUT 9-10 (-)
7
INPUT 11-12 (+)
41
INPUT 11-12 (-)
7
OUTPUT 11-12 (+)
41
OUTPUT 11-12 (-)
8
INPUT 13-14 (+)
42
INPUT 13-14 (-)
8
OUTPUT 13-14 (+)
42
OUTPUT 13-14 (-)
9
INPUT 15-16 (+)
43
INPUT 15-16 (-)
9
OUTPUT 15-16 (+)
43
OUTPUT 15-16 (-)
10
DTR IN (+)
44
DTR IN (-)
10
DTR OUT (+)
44
DTR OUT (-)
11
RTS OUT (+)
45
RTS OUT (-)
11
RTS IN (+)
45
RTS IN (-)
12
GND
46
GND
12
GND
46
GND
13
WORD CLOCK IN
(+)
47
WORD CLOCK IN (-)
13
WORD CLOCK OUT 47
(+)
WORD CLOCK OUT
(-)
14
WORD CLOCK OUT 48
(+)
WORD CLOCK OUT
(-)
14
WORD CLOCK IN
(+)
WORD CLOCK IN (-)
48
15
CONTROL IN (+)
49
CONTROL IN (-)
15
CONTROL OUT (+)
49
CONTROL OUT (-)
16
CONTROL OUT (+)
50
CONTROL OUT (-)
16
CONTROL IN (+)
50
CONTROL IN (-)
17
GND
51
ID6 IN
17
GND
51
ID6 OUT
18
GND
52
ID6 OUT
18
GND
52
ID6 IN
19
INPUT 17-18 (+)
53
INPUT 17-18 (-)
19
OUTPUT 17-18 (+)
53
OUTPUT 17-18 (-)
20
INPUT 19-20 (+)
54
INPUT 19-20 (-)
20
OUTPUT 19-20 (+)
54
OUTPUT 19-20 (-)
21
INPUT 21-22 (+)
55
INPUT 21-22 (-)
21
OUTPUT 21-22 (+)
55
OUTPUT 21-22 (-)
22
INPUT 23-24 (+)
56
INPUT 23-24 (-)
22
OUTPUT 23-24 (+)
56
OUTPUT 23-24 (-)
23
INPUT 25-26 (+)
57
INPUT 25-26 (-)
23
OUTPUT 25-26 (+)
57
OUTPUT 25-26 (-)
24
INPUT 27-28 (+)
58
INPUT 27-28 (-)
24
OUTPUT 27-28 (+)
58
OUTPUT 27-28 (-)
25
INPUT 29-30 (+)
59
INPUT 29-30 (-)
25
OUTPUT 29-30 (+)
59
OUTPUT 29-30 (-)
INPUT 31-32 (+)
60
INPUT 31-32 (-)
26
OUTPUT 31-32 (+)
60
OUTPUT 31-32 (-)
27
ID0 IN
61
ID1 IN
27
ID0 OUT
61
ID1 OUT
28
ID2 IN
62
ID3 IN
28
ID2 OUT
62
ID3 OUT
29
ID4 IN
63
ID5 IN
29
ID4 OUT
63
ID5 OUT
30
ID0 OUT
64
ID1 OUT
30
ID0 IN
64
ID1 IN
31
ID2 OUT
65
ID3 OUT
31
ID2 IN
65
ID3 IN
32
ID4 OUT
66
ID5 OUT
32
ID4 IN
66
ID5 IN
33
MSB //LSB IN
67
2CH//4CH IN
33
MSB //LSB OUT
67
2CH//4CH OUT
34
FG
68
FG
34
FG
68
FG
References
26
DME64N/DME24N Owner’s Manual
63
Connector Pin Assign
[NETWORK] Connector (100Base-TX Ethernet, RJ-45)
Pin
Connection
1
TxD+
2
TxD–
3
RxD+
4
Unused
5
Unused
6
RxD–
7
Unused
8
Unused
Straight/Cross Cable Wiring Details
Straight Cables
Pins
Pins
1 —— 1
1 —— 3
2 —— 2
2 —— 6
3 —— 3
3 —— 1
4 —— 4
4 —— 4
5 —— 5
5 —— 5
6 —— 6
6 —— 2
7 —— 7
7 —— 7
8 —— 8
8 —— 8
References
64
Cross Cables
DME64N/DME24N Owner’s Manual
Dimensions
Dimensions
Unit: mm
12.5
53.5
278
388
411.5
394
405
11
DME64N
423
145
17.5
96
132
18.5
4-M3
90
30
300
90
480
12.5
References
53.5
278
388
411.5
394
423
90
300
480
30
101
88
18
4-M3
18 52
405
11
DME24N
90
DME64N/DME24N Owner’s Manual
65
MIDI Data Format
MIDI Data Format
1. DME64N/24N MIDI Functions
1.1 Scene Change
Scene recall occurs according to the “MIDI Program Change Table” assignments when appropriate MIDI
Bank Select MSB/LSB and Program Change messages are received by the DME64N/24N.
Corresponding MIDI Bank Select MSB/LSB and Program Change messages are also transmitted by the
DME64N/24N when a scene recall operation is carried out via the panel controls, as specified by the “MIDI
Program Change Table” assignments.
Transmission does not occur when switching Configurations.
1.2 Parameter Control
MIDI Control Change and Parameter Change messages transmitted to the DME64N/24N can be used to
control parameters according to the “MIDI Control Change table” and “MIDI Parameter Change Table”
assignments.
Corresponding MIDI Control Change and Parameter Change messages are also transmitted by the
DME64N/24N when a parameter is edited out via the panel controls, as specified by the “MIDI Control
Change table” and “MIDI Parameter Change Table” assignments.
2. MIDI Data Flow
MIDI IN
MIDI Rx CH
SW1
Bank Select MSB/LSB
Program Change
(Scene Recall)
SW2
Control Change
(Parameter Edit)
SW3
Parameter Change
(Parameter Edit)
Bank Select MSB/LSB
Program Change
(Echo Back)
SW4
Control Change
(Echo Back)
SW5
Parameter Change
(Echo Back)
SW6
Bank Select MSB/LSB
Program Change
Control Change
Parameter Change
SW7
MIDI Tx CH
MIDI OUT
SW8
SW9
MIDI THRU
References
SW1: Program Change Rx Switch [On/Off]
SW2: Control Change Rx Switch [On/Off]
SW3: Parameter Change Rx Switch [On/Off]
SW4: Program Change Echo Back Switch [On/Off]
SW5: Control Change Echo Back Switch [On/Off]
SW6: Parameter Change Echo Back Switch [On/Off]
SW7: Program Change Tx Switch [On/Off]
SW8: Control Change Tx Switch [On/Off]
SW9: Parameter Change
MIDI Rx CH: MIDI Rx Channel (1-16)
MIDI Tx CH: MIDI Tx Channel (1-16)
66
DME64N/DME24N Owner’s Manual
MIDI Data Format
3. MIDI Setup
Specifies basic MIDI operation.
3.1 Host Select
Selects the input/output port to be used for MIDI communication.
3.2 DAW Controller
Specifies the DAW controller type when a DAW control surface is to be used to control the DME64N/24N.
When Type 1/2 is selected, Host Select is automatically set to MIDI.
3.3 MIDI Tx Channel
Specifies the MIDI transmit channel (1 ~ 16).
3.4 MIDI Rx Channel
Specified the MIDI receive channel (1 ~ 16).
3.5 MIDI Tx Switch
Program Change Tx Switch: turns Bank Select MSB, LSB, and Program Change transmission on or off.
Control Change Tx Switch: turns Control Change transmission on or off.
Parameter Change Tx Switch: turns Parameter Change transmission on or off.
3.6 MIDI Rx Switch
Program Change Rx Switch: turns Bank Select MSB, LSB, and Program Change reception on or off.
Control Change Rx Switch: turns Control Change reception on or off.
Parameter Change Rx Switch: turns Parameter Change reception on or off.
3.7 MIDI Omni Switch
Program Change Omni Switch: turns the Bank Select MSB, LSB, and Program Change omni mode on or
off.
Control Change Omni Switch: turns the Control Change omni mode on or off.
3.8 MIDI Echo Back Switch
Program Change Echo Back Switch: turns Bank Select MSB, LSB, and Program Change echo back on or
off.
Control Change Echo Back Switch: turns Control Change echo back on or off.
Parameter Change Echo Back Switch: turns Parameter Change echo back on or off.
4. MIDI Format
Number Format Notation
Numbers ending with “h” are in hexadecimal format, while numbers ending with “b” are binary format.
Characters “A” through “F” in hexadecimal numbers represent decimal values 10 through 15. Other
lowercase characters (usually “n” or “x”) represent any number.
MIDI Format Chart (Rx: receive, Tx: transmit)
Channel Message
Rx/Tx
Function
Control Change (Bnh)
Rx/Tx
Parameter Change
Program Change (Cnn)
Rx/Tx
Scene Recall
System Real-time Message
ACTIVE SENSING (FEH)
Rx
MIDI Cable Check
System Exclusive Message
Parameter Change
Rx/Tx
Parameter Change
DME64N/DME24N Owner’s Manual
References
Command
67
MIDI Data Format
4.1 Program Change (Cnh)
Receive
When the “Program Change Rx Switch” is on, Program Change messages are received on the MIDI
channel specified by the “MIDI Rx Channel” parameter.
If the “Program Change Omni Switch” is also on, however, Program Change messages will be received on
all MIDI channels regardless of the “MIDI Rx Channel” setting.
When a Program Change message is received, the scene assigned to the received program number in the
“MIDI Program Change table” is recalled.
The accepted Bank Select, Program Change range is as follows:
Bank Select MSB: 0
Bank Select LSB: 0 ~ 7
Program Change No.: 0 ~ 127
Transmit
When the “Program Change Tx Switch” is on, the corresponding Program Change number will be
transmitted as specified by the “MIDI Program Change table” and “MIDI Tx Channel” settings.
If multiple Program Change numbers are assigned to a single scene, the Bank Select MSB/LSB and
Program Change number corresponding to the lowest number will be transmitted.
Bank Select MSB
Status
Bnh (1101nnnnb)
Control Change
Data
00h (00000000b)
Control Change No. 0 (Bank Select MSB)
Data
nnh (0nnnnnnnb)
Control Value (Bank Select MSB No.)
Status
Bnh (1101nnnnb)
Control Change
Data
20h (00100000b)
Control Change No. 32 (Bank Select LSB)
nnh (0nnnnnnnb)
Control Value (Bank Select LSB No.)
Bank Select LSB
Program Change No.
Status
Cnh (1100nnnnb)
Program Change
Data
nnh (0nnnnnnnb)
Program Change No. (0-127)
4.2 Active Sensing (FEh)
Receive
MIDI communication will be initialized if no data is received within 300 ms after reception (Running Status,
etc., will be cleared).
Active Sensing
Status
FEh (11111110b)
Active Sensing
4.3 Control Change (Bnh)
Receive
When the “Control Change Rx Switch” is on, Control Change messages are received on the MIDI channel
specified by the “MIDI Rx Channel” parameter.
If the “Control Change Omni Switch” is also on, however, Control Change messages will be received on all
MIDI channels regardless of the “MIDI Rx Channel” setting.
Control Change parameter resolution is 128 regardless of the parameters effective range. For finer settings
use Parameter Change.
Transmit
References
When the “Control Change Tx Switch” is on, appropriate Control Change data will be transmitted when a
parameter is edited via the panel controls, as specified by the “MIDI Control Change table” and “MIDI Tx
Channel” settings.
Transmission does not occur when switching Configurations.
Refer to “Supplementary Information 1” for cases in which multiple messages are assigned to single
parameter.
Status
Bnh (1011nnnnb)
Control Change
Data
cch (0cccccccb)
Control Change No. (1-31,33-95,102-119)
vvh (0vvvvvvvb)
Control Value (0-127)
4.4 Parameter Change (F0h ~ F7h)
Receive
When the “Parameter Change Rx Switch” is On, Parameter Change messages are received on the MIDI
channel specified by the “Device ID (Rx Ch)” parameter.
68
DME64N/DME24N Owner’s Manual
MIDI Data Format
Transmit
When the “Parameter Change Tx Switch” is On, appropriate Parameter Change data will be transmitted
when a parameter is edited via the panel controls, as specified by the “MIDI Parameter Change table” and
“MIDI Tx Channel” settings.
Refer to “Supplementary Information 1” for cases in which multiple messages are assigned to single
parameter.
Refer to “Supplemental Information 2” for information on setting Parameter Data values.
Status
ID No.
DEVICE ID.
GROUP ID.
MODEL ID.
Parameter
Change No.
F0h
43h
10h
3Eh
10h
aah
aah
ddh
ddh
ddh
ddh
ddh
F7h
Parameter
Data Value
EOX
(11110000b)
(01000011b)
(0001xxxxb)
(00111110b)
(00010000b)
(0aaaaaaab)
(0aaaaaaab)
(0dddddddb)
(0dddddddb)
(0dddddddb)
(0dddddddb)
(0dddddddb)
(11110111b)
System Exclusive Message
Manufacturer's ID No.(YAMAHA)
Rx/Tx Channel (0-15)
Digital Mixer
Device Code (DME)
Parameter Change No. High
Parameter Change No. Low
data 0
data 1
data 2
data 3
data 4
End of Exclusive
Supplemental Information 1
Messages Transmitted When Multiple Messages are Assigned to the Same Parameter
The DME64N/24N MIDI transmit messages are specified via the “MIDI Control Change Table” and “MIDI
Parameter Change Table.” The “MIDI Control Change Table” and “MIDI Parameter Change Table” can be
set up via the DME Designer application.
Multiple messages can be assigned to a single parameter, but the DME64N/24N will only transmit one of
the assigned messages.
The transmitted messages are as follows:
• If a Control Change message and a Parameter Change message are assigned to the same parameter
the Control Change message will be transmitted.
• If multiple Control Change numbers are assigned to the same parameter the smallest Control Change
number message will be transmitted.
• If multiple Parameter Change numbers are assigned to the same parameter the smallest Parameter
Change number message will be transmitted.
Supplemental Information 2
Setting the Parameter Change Message Parameter Data Values
The Parameter change parameter values are expressed as 32-bit integers with or without parity.
• A parity bit (positive: 0, negative: 1) is added above the most significant value bit (bit 31).
• Fractional parameters will be converted according to the integer table.
• For integers with parity, negative numbers are expressed as the 2’s complement.
bit0
bit1
bit2
bit3
bit4
bit5
bit6
bit7
bit8
bit9
bit10
bit11
bit12
bit13
bit14
bit15
bit16
bit17
bit18
bit19
bit20
bit21
bit22
bit23
bit24
bit25
bit26
bit27
bit28
bit29
bit30
bit31
s i gn
0 0
data 0
data 1
data 2
data 3
data 4
Example
• When value is 1000 (decimal) / 3E8h (hexadecimal):
0
0
0
0
0
3
E
8
References
+
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 1 0 0 0
data 0 = 00h
data 1 = 00h
data 2 = 00h
data 3 = 07h
data 4 = 68h
• When value is 1000 (decimal) / FFFFFC18h (hexadecimal; 2’s complement of 3E8h):
-
F
F
F
F
F
C
1
8
0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 1 1 0 0 0
data 0 = 1Fh
data 1 = 7Fh
data 2 = 7Fh
data 3 = 78h
data 4 = 18h
DME64N/DME24N Owner’s Manual
69
MIDI Implementation Chart
YAMAHA
[Digital Mixing Engine]
Model DME64N/24N MIDI Implementation Chart
MIDI Implementation Chart
Function...
Transmitted
Recognized
Basic
Channel
Default
Changed
1
1
Mode
Default
Messages
Altered
×
×
**************
×
×
×
×
**************
×
×
Note
Number
: True voice
-
16
16
1
1
Velocity
Note ON
Note OFF
×
×
×
×
After
Touch
Key’s
Ch’s
×
×
×
×
×
×
Pitch Bend
0,32
1-31,33-95,102-119
O
O
Date :31-MAR-2004
Version : 1.0
*1
*2
-
Remarks
16
16
O
O
Memorized
*1
*2
Bank Select
Assignable
Control
Change
Prog
Change
: True #
System Exclusive
O 0
127
**************
O
*1
*3
O
: Song Pos. ×
: Song Sel. ×
×
: Tune
×
×
×
System
Real Time
: Clock
: Commands
×
×
×
×
All Sound Off
Reset All Cntrls
Local ON/OFF
All Notes OFF
Active Sense
Reset
×
×
×
×
×
×
×
×
×
×
O
×
:
:
:
Mes- :
sages :
:
References
Notes:
-
O
Common
Aux
0
0
127 *1
127
*3
Assignable
not include “DAW controller” command
*1 transmit/receive if program change switch is on.
*2 transmit/receive if control change switch is on.
*3 transmit/receive if parameter change switch is on.
Mode 1 : OMNI ON , POLY
Mode 3 : OMNI OFF, POLY
70
DME64N/DME24N Owner’s Manual
Mode 2 : OMNI ON , MONO
Mode 4 : OMNI OFF, MONO
O : Yes
× : No
Glossary
Glossary
Explanations
100Base-TX
A physical specification for a 100 Mbps Ethernet network connection using 2-conductor
Category 5 UTP cable included in the IEEE 802.3u standard. Maximum data transfer
distance is 100 meters.
10Base-T
A physical specification for a 10 Mbps Ethernet network connection using 2-conductor
Category 3 UTP cable included in the IEEE 802.3i standard. Maximum data transfer
distance is 100 meters.
BNC (Bayonet Nut Connector,
or Bayonet Neill Concelman)
A type of connector used for high-frequency connections using thin-core coaxial cable.
An internal spring ensures a solid connection.
Cascade
A means of connecting Yamaha digital audio equipment to allow transfer of audio, control,
and word clock signals. Yamaha cascade connections employ half-pitch 68-pin D-Sub
connectors.
Category 3
Electrical specifications for one type of UTP cable jointly developed by the TIA
(Telecommunications Industry Association) and EIA (Electronic Industry Alliance). Several
categories are specified according to electrical characteristics, with higher category
numbers denoting higher quality cable. Category 3 cable can be used for transmission
speeds up to 10 MHz.
Category 5
Electrical specifications for one type of UTP cable jointly developed by the TIA
(Telecommunications Industry Association) and EIA (Electronic Industry Alliance). Several
categories are specified according to electrical characteristics, with higher category
numbers denoting higher quality cable. Category 5 cable can be used for transmission
speeds up to 100 MHz.
Component
The basic modules that are combined to create DME64N/24N audio systems. In addition to
complete audio processors such as mixers, compressors, effects, crossovers, etc., a range
of smaller functions such as faders, switches, pan controls, and meters are also available.
Components can also be customized.
Configuration
A set of components and connections that make up an audio system in the DME64N/24N.
D-Sub
Another common form of connector that gets its name from the “D” shape of the connector.
This type of connector can be securely attached using screws. Individual “pins” are used to
connect each of the cable’s conductors. D-Sub connectors come in 9-pin, 15-pin, 25-pin,
37-pin, and other sizes.
DSP (Digital Signal processor)
A semiconductor chip (LSI), or device containing one or more such chips, developed
specifically to process large volumes of data in real time. Ideal for processing digital audio.
Ethernet
A network protocol jointly developed by the Xerox, DEC, and Intel corporations, and
codified in the IEEE 802.3 industry standard. Transfer speeds have increased to 100 Mbps,
1000 Mbps, and 10 Gbps from the initial 10 Mbps, while maintaining network compatibility.
Euroblock
A connector system consisting of plug and socket components that allows easy, solder-less
wiring for a range of installations and devices. Simply insert the wire into the plug slot,
tighten the screw, and plug into the socket to complete the connection.
GPI (General Purpose Interface)
A general-purpose control interface that can be used to allow control of the DME64N/24N
via external devices and custom-made controllers. Connections are made via a Euroblock
connector. The optional CP4SW, CP1SF, and CP4SF control panels also connect via GPI.
Initial Settings
The initial values and settings of all editable parameters that will be in effect when a device
is powered on for the first time after it is shipped from the factory. Also known as “default
settings” or “initial factory settings.”
MAC (Media Access Control) Address
The MAC address is also known as the Ethernet address, and is an independent address
assigned to all Ethernet devices worldwide. No two devices can have the same address.
MIDI (Musical Instrument Digital Interface)
An international standard for data communication between electronic musical instruments
and audio devices.
Mini-YGDAI (Yamaha General Digital Audio
Interface) card
A standard for I/O cards that can be installed to Yamaha audio products.
Phantom Power
A power delivery system that allows power to be delivered to devices along with audio
signals via standard balanced audio cables. The term “phantom” is applied because the
system uses the audio conductors for power delivery without disrupting the audio signal
– the power is not “seen” by the audio signal.
Preset Parameter
The parameter set of all components included in a configuration.
RJ-45
An 8-conductor modular connector used for Ethernet cable and ISDN telephone
connections. The appearance is similar to the RJ-11 connectors used for telephone lines,
but the connector is actually somewhat larger. “RJ” stands for “Registered Jack,” and is a
connector type included in the Bell System USOC (Universal Service Ordering Codes)
standards.
Router
An equipment that relays data in network by selecting the most effective route.
DME64N/DME24N Owner’s Manual
References
Terms
71
Glossary
Terms
RS-232C
A serial communication protocol that allows data transfer over distances of up to 15 meters.
RS232C interfaces usually employ 9-pin D-sub connectors. “RS” stands for
“Recommended Standard,” and one of the standards developed by the EIA (Electronic
Industry Alliance).
RS-422
A balanced serial communication protocol that allows data transfer over distances of up to
1 kilometer. RS-422 offers higher data rates and greater reliability than the RS-232C
protocol.
Sampling Frequency
The number of times per second an analog audio signal is “sampled” when it is being
converted to digital audio.
Scene
A complete audio setup including configuration data and the related component preset
parameters. Up to 999 scenes can be stored for each device group in a DME64N/24N
audio system.
STP (Shielded Twisted Pair) Cable
A data transmission cable consisting of a shielded twisted pair. This type of cable is more
resistant to noise and interference than UTP (Unshielded Twisted Pair) cable.
Network Switch
A network switch which automatically connects only ports through which communication is
currently taking place. This reduces network load while maximizing security. This type of
switch can often mediate between devices having different transmission speeds and
standards.
USB (Universal Serial Bus)
A serial bus primarily used for connecting peripheral devices to computer equipment.
The USB 1.1 standard allows data transfer rates of up to 12 Mbps.
UTP (Unshielded Twisted pair) Cable
A data transmission cable consisting of an unshielded twisted pair. This type of cable is less
expensive and more commonly available than STP (Shielded Twisted Pair) cable, and is
widely used in 10Base-T and 100Base-TX network connections.
Word Clock
A signal used to synchronize multiple interconnected digital audio devices. The word clock
frequency will be the same as the sampling frequency of the audio signal being processed.
References
72
Explanations
DME64N/DME24N Owner’s Manual
Index
+48V ............................................................................ 53
[E] [] [] [F] Buttons ............................................... 15
100Base-TX (Glossary) ............................................... 71
10Base-T (Glossary) .................................................... 71
[96kHz] [88.2kHz] [48kHz] [44.1kHz] Indicator ............ 14
Display ......................................................................... 15
Display Setup (Disp) Page ........................................... 46
DME Designer ............................................................. 13
DME-N Network Driver ................................................ 23
DSP (Digital Signal processor) (Glossary) ................... 71
D-Sub (Glossary) ......................................................... 71
A
[AC IN] Connector ........................................................ 16
area ................................................................................ 9
audio ............................................................................ 11
B
Band Output Level ....................................................... 41
Battery ......................................................................... 45
BNC (Bayonet Nut Connector, or Bayonet Neill
Concelman) (Glossary) ................................................ 71
E
[ENTER] Button ........................................................... 15
Error Messages ........................................................... 56
Ethernet (Glossary) ...................................................... 71
Ethernet Connection .................................................... 23
Euroblock ..................................................................... 26
Euroblock (Glossary) ................................................... 71
[EXT. CLOCK] Indicator ............................................... 14
F
C
cable clamp .................................................................. 18
Calibration Info ............................................................. 51
[CANCEL] Button ......................................................... 15
Card Name .................................................................. 51
CASCAD Page ............................................................ 53
Cascade (Glossary) ..................................................... 71
Cascade (WCLK Page) ............................................... 50
CASCADE connection ................................................. 31
[CASCADE IN] [CASCADE OUT] Connectors ...... 17, 31
cascade loop ................................................................ 31
Cascade Setup (CASCAD) Page ................................ 53
Category 3 (Glossary) .................................................. 71
Category 5 (Glossary) .................................................. 71
CH (Double Channel) (Slot Page) ............................... 51
CH (MIDI Page) ........................................................... 50
component (Glossary) ................................................. 71
Components .................................................................. 9
Configuration ................................................................. 9
configuration (Glossary) ............................................... 71
connector pin assign .................................................... 63
Control Change ............................................................ 50
control I/O .................................................................... 62
CP4SW, CP4SF, and CP1SF ...................................... 55
D
Date ............................................................................. 45
Device control .............................................................. 11
device group .................................................................. 9
Device Group (Net Page) ............................................ 46
Device group control .................................................... 11
Dial ............................................................................... 15
dimensions ................................................................... 65
Disp Page .................................................................... 46
Format (HA Page) ........................................................ 52
Format (Slot Page) ...................................................... 51
Frequency .................................................................... 41
front panel .................................................................... 14
Frq ............................................................................... 53
Fs ................................................................................. 50
G
Gain ............................................................................. 52
GPI (General Purpose Interface) ................................. 33
GPI (General Purpose Interface) (Glossary) ............... 71
GPI connection ............................................................ 33
[GPI] Connector ..................................................... 16, 33
Ground Screw .............................................................. 16
H
HA ................................................................................ 52
HA Page ...................................................................... 52
Head Amplifier Setup (HA) Page ........................... 52, 54
Head Margin ................................................................ 53
High-pass Filter ............................................................ 53
High-pass Filter Frequency .......................................... 53
[HOME] Button ............................................................. 15
HPF .............................................................................. 53
I
I/O card ........................................................................ 20
I/O card (installation procedure) .................................. 21
I/O Slots ....................................................................... 17
ICP1 ............................................................................. 55
[IN] [OUT] Connectors ........................................... 17, 26
Info Page ..................................................................... 45
initial settings (Glossary) .............................................. 71
Input/Output Level Display ........................................... 42
DME64N/DME24N Owner’s Manual
73
Int ................................................................................. 50
IP Adr. .......................................................................... 46
L
L/R Select .................................................................... 41
Label ............................................................................ 45
LCD Backlight .............................................................. 47
LCD Contrast ............................................................... 47
[LEVEL] Button ............................................................ 15
Level Meter display ...................................................... 42
Link Mode .................................................................... 46
List Parameter ............................................................. 38
Lock Page .................................................................... 47
M
MAC (Media Access Control) Address (Glossary) ....... 71
MAC Adr. ..................................................................... 46
Main display ................................................................. 35
[MASTER] Indicator ..................................................... 15
MAX ............................................................................. 51
Meter Fall Time ............................................................ 47
MIDI (Musical Instrument Digital Interface) (Glossary) 71
MIDI connection ........................................................... 30
MIDI Data Format ........................................................ 66
MIDI Implementation Chart .......................................... 70
[MIDI IN] [MIDI OUT] [MIDI THRU] Connectors .......... 16
[MIDI] Indicator ............................................................ 15
MIDI Page .................................................................... 49
MIDI Setup (MIDI) Page .............................................. 49
MIN .............................................................................. 51
Mini-YGDAI (Yamaha General Digital Audio Interface)
card (Glossary) ............................................................ 71
Misc Page .................................................................... 48
Miscellaneous Setup (Misc) Page ............................... 48
Mixer I/O ...................................................................... 53
[MONITOR] Button ...................................................... 15
Monitoring .................................................................... 40
[MUTE] Button ............................................................. 15
Mute Indicator .............................................................. 35
Mute Switching ............................................................ 39
N
Net Page ...................................................................... 46
[NETWORK] Connector ......................................... 17, 23
[NETWORK] Indicator .................................................. 14
Network Settings .......................................................... 22
Network Settings (Net) Page ....................................... 46
Network Switch (Glossary) .......................................... 72
Numeric Parameter ...................................................... 36
O
ON/OFF Parameter ..................................................... 38
Options ........................................................................ 55
Output Level Control .................................................... 39
Output Level Indicator .................................................. 35
74
DME64N/DME24N Owner’s Manual
P
Page Scroll Bar ............................................................ 35
Panel Lock ................................................................... 36
Panel Lock Boot ........................................................... 47
Panel Lock Icon ........................................................... 35
Panel Lock Target ........................................................ 47
Parameter Change ...................................................... 50
Parameter Edit display ................................................. 36
Peak Hold (Level Meter display) .................................. 42
Peak Hold (Spectrum display) ..................................... 41
[PEAK] Indicator .......................................................... 15
Phantom Master Switch ............................................... 53
Phantom Power (Glossary) .......................................... 71
[PHONES] Jack ........................................................... 15
[PHONES LEVEL] Control ........................................... 15
Port (MIDI Page) .......................................................... 49
[POWER] Switch .......................................................... 15
preparation ............................................................. 18, 26
preset parameter (Glossary) ........................................ 71
Probe Monitor Function ............................................... 41
Program Change ......................................................... 50
Protocol (MIDI Page) ................................................... 50
R
rear panel ..................................................................... 16
Remote Connection ..................................................... 28
[REMOTE] Connector ............................................ 17, 28
Remote Page ............................................................... 48
Reset (GPI Page) ........................................................ 51
Reset (Slot Page) ........................................................ 51
RJ-45 (Glossary) .......................................................... 71
router (Glossary) .......................................................... 71
RS-232C (Glossary) .................................................... 72
RS-422 (Glossary) ....................................................... 72
S
sampling frequency (Glossary) .................................... 72
Scene ........................................................................... 10
scene (Glossary) .......................................................... 72
Scene Information ........................................................ 35
[SCENE NUMBER] Indicator ....................................... 15
Scene Recall ................................................................ 39
Scene Store (Misc Page) ............................................. 48
Scene Store (Operation) .............................................. 40
security cover mounting ............................................... 18
Security Setup (Lock) Page ......................................... 47
[SIGNAL] Indicator ....................................................... 15
Slot Information (Slot) Page ......................................... 51
Slot Page ..................................................................... 51
SLOT1~4 ..................................................................... 51
SP (Double Speed) ...................................................... 51
specifications ............................................................... 60
Spectrum display ......................................................... 41
status message ............................................................ 56
STP (Shielded Twisted Pair) Cable (Glossary) ............ 72
T
troubleshooting ............................................................ 59
U
Unit No ......................................................................... 53
USB (Universal Serial Bus) (Glossary) ........................ 72
USB Connection .......................................................... 22
[USB] Connector .......................................................... 14
USB-MIDI Driver .......................................................... 22
User Defined button ....................................................... 9
User Defined Button (Edit) ........................................... 38
User Defined Button Names ........................................ 35
User Defined buttons (User Defined parameters) ......... 9
User Defined Lock ....................................................... 47
Utility (Lock Page) ........................................................ 47
[UTILITY] Button .......................................................... 15
Utility display ................................................................ 43
Utility display (Operation) ............................................. 45
UTP (Unshielded Twisted pair) Cable (Glossary) ........ 72
V
Version ......................................................................... 45
W
WCIN ........................................................................... 50
WCLK (HA Page) ......................................................... 52
WCLK Page ................................................................. 50
Word Clock (Glossary) ................................................. 72
WORD CLOCK connection .......................................... 32
[WORD CLOCK IN] [WORD CLOCK OUT] Connectors
............................................................................... 16, 32
word clock master ........................................................ 32
Word Clock Setup (WCLK) Page ................................. 50
word clock slave .......................................................... 32
Z
zones ............................................................................. 9
DME64N/DME24N Owner’s Manual
75
MEMO
76
DME64N/DME24N Owner’s Manual
MEMO
DME64N/DME24N Owner’s Manual
77
MEMO
78
DME64N/DME24N Owner’s Manual
For details of products, please contact your nearest Yamaha
representative or the authorized distributor listed below.
Pour plus de détails sur les produits, veuillez-vous adresser à Yamaha ou
au distributeur le plus proche de vous figurant dans la liste suivante.
NORTH AMERICA
CANADA
Yamaha Canada Music Ltd.
135 Milner Avenue, Toronto, Ontario,
M1S 3R1, Canada
Tel: 416-298-1311
U.S.A.
Yamaha Corporation of America
6600 Orangethorpe Avenue, Buena Park, CA 90620,
U.S.A.
Tel: 714-522-9011
CENTRAL & SOUTH AMERICA
MEXICO
Yamaha de México, S.A. de C.V.
Av. Insurgentes Sur 1647 Piso 9, Col. San José
Insurgentes, Delegación Benito Juárez, México,
D.F., C.P. 03900
Tel: 55-5804-0600
BRAZIL
Yamaha Musical do Brasil Ltda.
Rua Joaquim Floriano, 913 - 4º andar, Itaim Bibi,
CEP 04534-013 São Paulo, SP. BRAZIL
Tel: 011-3704-1377
ARGENTINA
Yamaha Music Latin America, S.A.,
Sucursal Argentina
Olga Cossettini 1553, Piso 4 Norte,
Madero Este-C1107CEK
Buenos Aires, Argentina
Tel: 011-4119-7000
VENEZUELA
Yamaha Music Latin America, S.A.,
Sucursal Venezuela
C.C. Manzanares Plaza P4
Ofic. 0401- Manzanares-Baruta
Caracas Venezuela
Tel: 58-212-943-1877
PANAMA AND OTHER LATIN
AMERICAN COUNTRIES/
CARIBBEAN COUNTRIES
Yamaha Music Latin America, S.A.
Torre Banco General, Piso No.7, Marbella,
Calle 47 y Aquilino de la Guardia,
Ciudad de Panamá, República de Panamá
Tel: +507-269-5311
EUROPE
THE UNITED KINGDOM/IRELAND
Yamaha Music Europe GmbH (UK)
Sherbourne Drive, Tilbrook, Milton Keynes,
MK7 8BL, U.K.
Tel: 01908-366700
GERMANY
Yamaha Music Europe GmbH
Siemensstraße 22-34, 25462 Rellingen, Germany
Tel: 04101-3030
SWITZERLAND/LIECHTENSTEIN
Yamaha Music Europe GmbH
Branch Switzerland in Zürich
Seefeldstrasse 94, 8008 Zürich, Switzerland
Tel: 044-387-8080
AUSTRIA/BULGARIA
Yamaha Music Europe GmbH Branch Austria
Schleiergasse 20, A-1100 Wien, Austria
Tel: 01-60203900
CZECH REPUBLIC/HUNGARY/
ROMANIA/SLOVAKIA/SLOVENIA
Yamaha Music Europe GmbH
Branch Austria (Central Eastern Europe Office)
Schleiergasse 20, A-1100 Wien, Austria
Tel: 01-60203900
POLAND/LITHUANIA/LATVIA/ESTONIA
Yamaha Music Europe GmbH
Branch Poland Office
ul. Wrotkowa 14 02-553 Warsaw, Poland
Tel: 022-500-2925
PA35
Die Einzelheiten zu Produkten sind bei Ihrer unten aufgeführten
Niederlassung und bei Yamaha Vertragshändlern in den jeweiligen
Bestimmungsländern erhältlich.
Para detalles sobre productos, contacte su tienda Yamaha más
cercana o el distribuidor autorizado que se lista debajo.
MALTA
ASIA
Olimpus Music Ltd.
The Emporium, Level 3, St. Louis Street Msida
MSD06
Tel: 02133-2144
THE PEOPLE’S REPUBLIC OF CHINA
Yamaha Music & Electronics (China) Co.,Ltd.
2F, Yunhedasha, 1818 Xinzha-lu, Jingan-qu,
Shanghai, China
Tel: 021-6247-2211
NETHERLANDS/BELGIUM/
LUXEMBOURG
INDIA
Yamaha Music Europe Branch Benelux
Clarissenhof 5-b, 4133 AB Vianen, Netherlands
Tel: 0347-358 040
Yamaha Music India Pvt. Ltd.
Spazedge building, Ground Floor, Tower A, Sector
47, Gurgaon- Sohna Road, Gurgaon, Haryana, India
Tel: 0124-485-3300
FRANCE
Yamaha Music Europe
7 rue Ambroise Croizat, Zone d'activites Pariest,
77183 Croissy-Beaubourg, France
Tel: 01-64-61-4000
INDONESIA
PT. Yamaha Musik Indonesia (Distributor)
Yamaha Music Center Bldg. Jalan Jend. Gatot
Subroto Kav. 4, Jakarta 12930, Indonesia
Tel: 021-520-2577
ITALY
Yamaha Music Europe GmbH, Branch Italy
Viale Italia 88, 20020 Lainate (Milano), Italy
Tel: 02-935-771
KOREA
SPAIN/PORTUGAL
Yamaha Music Europe GmbH Ibérica, Sucursal
en España
Ctra. de la Coruna km. 17,200, 28231
Las Rozas (Madrid), Spain
Tel: +34-91-639-88-88
GREECE
Philippos Nakas S.A. The Music House
147 Skiathou Street, 112-55 Athens, Greece
Tel: 01-228 2160
TAIWAN
Yamaha Music Europe GmbH, Tyskland – filial
Denmark
Generatorvej 6A, DK-2730 Herlev, Denmark
Tel: 44 92 49 00
Yamaha Music Europe GmbH Germany Norwegian Branch
Grini Næringspark 1, N-1361 Østerås, Norway
Tel: 67 16 78 00
RUSSIA
Yamaha Music (Russia) LLC.
Room 37, bld. 7, Kievskaya street, Moscow,
121059, Russia
Tel: 495 626 5005
OTHER EUROPEAN COUNTRIES
Yamaha Music Europe GmbH
Siemensstraße 22-34, 25462 Rellingen, Germany
Tel: +49-4101-3030
Yamaha Music (Malaysia) Sdn., Bhd.
No.8, Jalan Perbandaran, Kelana Jaya, 47301
Petaling Jaya, Selangor, Malaysia
Tel: 03-78030900
Yamaha Music (Asia) Private Limited
Block 202 Hougang Street 21, #02-00,
Singapore 530202, Singapore
Tel: 65-6747-4374
Yamaha Music Europe GmbH Germany filial
Scandinavia
J. A. Wettergrensgata 1, Box 30053
S-400 43 Göteborg, Sweden
Tel: +46 31 89 34 00
NORWAY
MALAYSIA
SINGAPORE
SWEDEN/FINLAND/ICELAND
DENMARK
Yamaha Music Korea Ltd.
8F, 9F, Dongsung Bldg. 158-9 Samsung-Dong,
Kangnam-Gu, Seoul, Korea
Tel: 02-3467-3300
Yamaha Music & Electronics Taiwan Co.,Ltd.
3F, No.6, Section 2 Nan-Jing East Road, Taipei,
Taiwan R.O.C.
Tel: 02-2511-8688
THAILAND
Siam Music Yamaha Co., Ltd.
3, 4, 15 and 16th floor, Siam Motors Building,
891/1 Rama 1 Road, Wangmai,
Pathumwan, Bangkok 10330, Thailand
Tel: 02-215-2622
VIETNAM
Yamaha Music Vietnam Company Limited
15th Floor, Nam A Bank Tower, 201-203 Cach
Mang Thang Tam St., Ward 4, Dist.3,
Ho Chi Minh City, Vietnam
Tel: +84-8-3818-1122
OTHER ASIAN COUNTRIES
Yamaha Corporation
Sales & Marketing Division
Nakazawa-cho 10-1, Naka-ku, Hamamatsu,
Japan 430-8650
Tel: +81-53-460-2312
AFRICA
Yamaha Music Gulf FZE
Office JAFZA 16-512, P.O.Box 17328,
Jebel Ali - Dubai, UAE
Tel: +971-4-881-5868
MIDDLE EAST
TURKEY
Yamaha Music Europe GmbH
Merkezi Almanya Türkiye İstanbul Şubesi
Maslak Meydan Sokak No:5 Spring Giz Plaza
Bağımsız Böl. No:3, 34398 Şişli İstanbul
Tel: +90-212-999-8010
OCEANIA
AUSTRALIA
Yamaha Music Australia Pty. Ltd.
Level 1, 99 Queensbridge Street, Southbank,
Victoria 3006, Australia
Tel: 3-9693-5111
COUNTRIES AND TRUST
TERRITORIES IN PACIFIC OCEAN
Yamaha Corporation
Sales & Marketing Division
Nakazawa-cho 10-1, Naka-ku, Hamamatsu,
Japan 430-8650
Tel: +81-53-460-2312
CYPRUS
Yamaha Music Europe GmbH
Siemensstraße 22-34, 25462 Rellingen, Germany
Tel: 04101-3030
OTHER COUNTRIES
Yamaha Music Gulf FZE
Office JAFZA 16-512, P.O.Box 17328,
Jebel Ali - Dubai, U.A.E
Tel: +971-4-881-5868
HEAD OFFICE Yamaha Corporation, PA Development Division
Nakazawa-cho 10-1, Naka-ku, Hamamatsu, Japan 430-8650
Yamaha Pro Audio global web site:
http://www.yamahaproaudio.com/
Yamaha Manual Library
http://www.yamaha.co.jp/manual/
C.S.G., PA Development Division
© 2004-2013 Yamaha Corporation
308MWTO-H0
Printed in Japan
WW20480