Black Box LMC213A-SMST-R2 Manual de usuario

Categoría
Convertidores de medios de red
Tipo
Manual de usuario
LMC213A-MMSC-R2
LMC213AE-MMSC-R2
LMC213A-MMST-R2
LMC213AE-MMST-R2
LMC213A-SMSC-R2
LMC213AE-SMSC-R2
LMC213A-SMST-R2
LMC213AE-SMST-R2
FlexPoint
100Fx/Tx
©Copyright 1999-2003. Black Box Corporation. All rights reserved.
1000 Park Drive z Lawrence, PA 15055-1018
724-746-5500 z Fax 724-746-0746
Overview and Description:
The FlexPoint 100Fx/Tx converts between Fast Ethernet
100Base-Fx fiber and 100Base-Tx twisted pair (RJ45 UTP)
cabling. It operates in half-duplex (HD) or full-duplex (FD).
The following multimode (MM) and single-mode (SM)
models are described here:
Model Fiber Type Distance
LMC213A-MMSC-R2 1310nm,MM,SC 2km / 1.2 mi.
LMC213AE-MMSC-R2 1310nm,MM,SC 2km / 1.2 mi.
LMC213A-SMSC-R2 1310nm,SM,SC 28km / 17.4 mi.
LMC213AE-SMSC-R2 1310nm,SM,SC 28km / 17.4 mi.
LMC213A-MMST-R2 1310nm,MM,ST 2km / 1.2 mi.
LMC213AE-MMST-R2 1310nm,MM,ST 2km / 1.2 mi.
LMC213A-SMST-R2 1310nm,SM,ST 25km / 15 mi.
LMC213AE-SMST-R2 1310nm,SM,ST 25km / 15 mi.
LMC213A-SM-XLH-R2 1550nm, SM,SC 85km / 52.8 mi.
LMC213AE-SM-XLH-R2 1550nm, SM,SC 85km / 52.8 mi.
LMC213A-SM-SLH-R2 1550nm, SM,SC 110km / 68 mi.
LMC213AE-SM-SLH-R2 1550nm, SM,SC 110km / 68 mi.
LMC214A-SCP-R2 1310nm,SM,SC 58km / 35 mi.
LMC214AE-SCP-R2 1310nm,SM,SC 58km / 35 mi.
LMC214A-STP-R2 1310nm,SM,ST 58km / 35 mi.
LMC214AE-STP-R2 1310nm,SM,ST 58km / 35 mi.
Installation and Configuration
Power Adapter Notice:
1. When used in a stand-alone configuration, this
product is intended to be used only with a Listed
Direct Plug-In Power Unit marked “Class 2” and
rated at 9Vdc, 1 Amp.
2. This product should always be used only with its
enclosed Power Unit.
WARNING!
Before plugging the Power Adapter to any
wall outlet or AC power source, verify that
the power on the unit is appropriate for
your AC line voltage source.
Mounting and Cable Attachment:
The FlexPoint 100Fx/Tx can be individually wall-
mounted using a wall-mounting kit, rack-mounted using
a 5-position space-saver shelf, or inserted in a
14-position power-redundant FlexPoint Powered
Chassis. When wall-mounting or shelf-mounting, attach
the power adapter unit.
Attach the unit’s RJ45 UTP via a category 5 cable to
a 100Base-Tx Fast Ethernet device.
Attach the units’s fiber via cable to a 100Base-Fx
Fast Ethernet device. The FlexPoint transmit (Tx)
must attach to the receive side on the other device;
the receive (Rx) must attach to the transmit.
Switch Settings:
“RJ45 Cross-Over” Switch: When connecting the UTP
to a hub or switch, set to “Straight-Through” (factory setting).
When connecting to a workstation, set it to “Cross-Over.”
“Auto-Negotiation/Manual” Switch: When in
“Manual” (factory setting), the FlexPoint operation is
selected by the “Full-Duplex/Half-Duplex” switch.
When in “Auto-Negotiation”, the FlexPoint automatically
selects full or half duplex operation depending on the
“Full-Duplex/Half-Duplex” switch position and the
features of the device connected to its UTP cable.
“Full-Duplex/Half-Duplex” Switch: When the “Auto-
Negotiation/Manual” switch is in “Manual” position,
the “Full-Duplex/Half-Duplex” switch determines the
type of duplex operation mode. When the “Auto-
Negotiation/Manual” switch is in “Auto-Negotiation”
position, the “Full-Duplex/Half-Duplex” switch
advertises its setting to the device connected to the
UTP port. When set to “Half-Duplex” (factory setting),
the FlexPoint will operate in half duplex. When set to
“Full-Duplex” the FlexPoint will operate in full-duplex
or half-duplex depending on the features supported
by the other device.
Half-duplex must be used when connecting to a hub.
Full-duplex can be used when connecting switches or
between a switch and a full-duplex workstation.
LED Indicators:
LED Color Description
Power On Yellow Power applied
Auto-Neg Green UTP switch is set to “Auto-Negotiation”
position.
Full-Duplex Green Full-Duplex selected.
Half-Duplex Green Half-Duplex selected.
Fiber Lk/Rx Green Solid: Link
Flashing: Data received.
Fiber Error Red Data errors detected on fiber.
UTP Lk/Rx Green Solid: Link,Flashing: Data received.
UTP Error Red Data errors detected on UTP.
LMC214A-SCP-R2
LMC214AE-SCP-R2
LMC214A-STP-R2
LMC214AE-STP-R2
LMC213A-SM-XLH-R2
LMC213AE-SM-XLH-R2
LMC213A-SM-SLH-R2
LMC213AE-SM-SLH-R2
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX
(outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a
week; Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation,
1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com
SPECIFICATIONS:
Protocol: IEEE 802.3, 100Base-Fx,
100Base-Tx
Connectors and Cables:
Twisted Pair UTP: RJ45, Category 5 or higher
Fiber: SC or ST
Multimode: 50/125, 62.5/125, 100/140µm
Single-mode: 9/125µm
Supported Distances: Half-Duplex Full-Duplex
Twisted Pair UTP: 100m / 328ft. 100m/328 ft.
MM 1310nm fiber: 412m/1,350ft. 2 km/1.2 mi.
SM 1310nm fiber,STD: 412m/1,350ft. 28km/17.4 mi.
SM 1310nm fiber,EXT: 412m/1,350ft. 58km/35 mi.
SM 1550nm XLH fiber: 412m/1,350ft. 85km/52.8 mi.
SM 1550nm SLH fiber: 412m/1,350ft. 110km/68 mi.
Power: 9VDC / 500 mA
Temperature: 0 to 40 degrees C
Humidity: 0-90% (non-condensing)
TRADEMARKS
All applied-for and registered trademarks are the property
of their respective owners.
FEDERAL COMMUNICATIONS COMMISSION AND
CANADIAN DEPARTMENT OF COMMUNICATIONS
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio
frequency energy and if not installed and used properly, that is, in
strict accordance with the manufacturer’s instructions, may cause
interference to radio communication. It has been tested and found
to comply with the limits for a Class A computing device in
accordance with the specifications in subpart J of Part 15 of FCC
rules, which are designed to provide reasonable protection against
such interference when the equipment is operated in a commercial
environment. Operation of this equipment in a residential area is
likely to be cause interference, in which case the user at his own
expense will be required to take whatever measures may be neces-
sary to correct the interference. Changes or modifications not ex-
pressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio
noise emission from digital apparatus set out in the Radio
Interference Regulation of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits
radioélectriques dépassant les limites applicables aux appareils
numéirques de las classe A prescrites dans le Règlement sur
le brouillage radioélectrique publié par le ministère des
Communications du Canada.
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
1. Todas las instrucciones de seguridad y operación deberán ser
leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas
para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones
de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por
ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca
de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o
pedelstales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo
como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo
eléctrico más allá a lo descrito en las instrucciones de operación.
Todo otro servicio deberá ser referido a personal de servicio
calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición
no interfiera su uso. La colocación del aparato eléctrico sobre una
cama, sofá, alfombra or superficie similar puede bloquea la
ventilación, no se debe colocar en libreros o gabinetes que impidan
el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes
de calor como radiadores, registros de calor, estufas u ostros
aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder
sólo del tipo descrito en el instructivo de operación, o como se
indique en el aparato.
12. Precación debe ser tomada de tal manera que la tierra fisica y la
polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera
que no sean pisados ni pellizcados por objetos colocados sobre o
contra ellos, poniendo particular atención a los contactos y
receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a
las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos
de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo
no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no
sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del
aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio
en su desempeño; o
E: El aparto ha sido tirado o su cubierta ha sido dañada.
040-01005-R21 08/03
SPECIFICATIONS:
Protocol: IEEE 802.3, 100Base-Fx,
100Base-Tx
Connectors and Cables:
Twisted Pair UTP: RJ45, Category 5 or higher
Fiber: SC or ST
Multimode: 50/125, 62.5/125, 100/140µm
Single-mode: 9/125µm
Supported Distances: Half-Duplex Full-Duplex
Twisted Pair UTP: 100m / 328ft. 100m/328 ft.
MM 1310nm fiber: 412m/1,350ft. 2 km/1.2 mi.
SM 1310nm fiber,STD: 412m/1,350ft. 28km/17.4 mi.
SM 1310nm fiber,EXT: 412m/1,350ft. 58km/35 mi.
SM 1550nm XLH fiber: 412m/1,350ft. 85km/52.8 mi.
SM 1550nm SLH fiber: 412m/1,350ft. 110km/68 mi.
Power: 9VDC / 500 mA
Temperature: 0 to 40 degrees C
Humidity: 0-90% (non-condensing)
TRADEMARKS
All applied-for and registered trademarks are the property
of their respective owners.
FEDERAL COMMUNICATIONS COMMISSION AND
CANADIAN DEPARTMENT OF COMMUNICATIONS
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio
frequency energy and if not installed and used properly, that is, in
strict accordance with the manufacturer’s instructions, may cause
interference to radio communication. It has been tested and found
to comply with the limits for a Class A computing device in
accordance with the specifications in subpart J of Part 15 of FCC
rules, which are designed to provide reasonable protection against
such interference when the equipment is operated in a commercial
environment. Operation of this equipment in a residential area is
likely to be cause interference, in which case the user at his own
expense will be required to take whatever measures may be neces-
sary to correct the interference. Changes or modifications not ex-
pressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio
noise emission from digital apparatus set out in the Radio
Interference Regulation of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits
radioélectriques dépassant les limites applicables aux appareils
numéirques de las classe A prescrites dans le Règlement sur
le brouillage radioélectrique publié par le ministère des
Communications du Canada.
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
1. Todas las instrucciones de seguridad y operación deberán ser
leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas
para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones
de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por
ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca
de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o
pedelstales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo
como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo
eléctrico más allá a lo descrito en las instrucciones de operación.
Todo otro servicio deberá ser referido a personal de servicio
calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición
no interfiera su uso. La colocación del aparato eléctrico sobre una
cama, sofá, alfombra or superficie similar puede bloquea la
ventilación, no se debe colocar en libreros o gabinetes que impidan
el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes
de calor como radiadores, registros de calor, estufas u ostros
aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder
sólo del tipo descrito en el instructivo de operación, o como se
indique en el aparato.
12. Precación debe ser tomada de tal manera que la tierra fisica y la
polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera
que no sean pisados ni pellizcados por objetos colocados sobre o
contra ellos, poniendo particular atención a los contactos y
receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a
las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos
de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo
no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no
sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del
aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio
en su desempeño; o
E: El aparto ha sido tirado o su cubierta ha sido dañada.
040-01005-R21 08/03
LMC213A-MMSC-R2
LMC213AE-MMSC-R2
LMC213A-MMST-R2
LMC213AE-MMST-R2
LMC213A-SMSC-R2
LMC213AE-SMSC-R2
LMC213A-SMST-R2
LMC213AE-SMST-R2
FlexPoint
100Fx/Tx
©Copyright 1999-2003. Black Box Corporation. All rights reserved.
1000 Park Drive z Lawrence, PA 15055-1018
724-746-5500 z Fax 724-746-0746
Overview and Description:
The FlexPoint 100Fx/Tx converts between Fast Ethernet
100Base-Fx fiber and 100Base-Tx twisted pair (RJ45 UTP)
cabling. It operates in half-duplex (HD) or full-duplex (FD).
The following multimode (MM) and single-mode (SM)
models are described here:
Model Fiber Type Distance
LMC213A-MMSC-R2 1310nm,MM,SC 2km / 1.2 mi.
LMC213AE-MMSC-R2 1310nm,MM,SC 2km / 1.2 mi.
LMC213A-SMSC-R2 1310nm,SM,SC 28km / 17.4 mi.
LMC213AE-SMSC-R2 1310nm,SM,SC 28km / 17.4 mi.
LMC213A-MMST-R2 1310nm,MM,ST 2km / 1.2 mi.
LMC213AE-MMST-R2 1310nm,MM,ST 2km / 1.2 mi.
LMC213A-SMST-R2 1310nm,SM,ST 25km / 15 mi.
LMC213AE-SMST-R2 1310nm,SM,ST 25km / 15 mi.
LMC213A-SM-XLH-R2 1550nm, SM,SC 85km / 52.8 mi.
LMC213AE-SM-XLH-R2 1550nm, SM,SC 85km / 52.8 mi.
LMC213A-SM-SLH-R2 1550nm, SM,SC 110km / 68 mi.
LMC213AE-SM-SLH-R2 1550nm, SM,SC 110km / 68 mi.
LMC214A-SCP-R2 1310nm,SM,SC 58km / 35 mi.
LMC214AE-SCP-R2 1310nm,SM,SC 58km / 35 mi.
LMC214A-STP-R2 1310nm,SM,ST 58km / 35 mi.
LMC214AE-STP-R2 1310nm,SM,ST 58km / 35 mi.
Installation and Configuration
Power Adapter Notice:
1. When used in a stand-alone configuration, this
product is intended to be used only with a Listed
Direct Plug-In Power Unit marked “Class 2” and
rated at 9Vdc, 1 Amp.
2. This product should always be used only with its
enclosed Power Unit.
WARNING!
Before plugging the Power Adapter to any
wall outlet or AC power source, verify that
the power on the unit is appropriate for
your AC line voltage source.
Mounting and Cable Attachment:
The FlexPoint 100Fx/Tx can be individually wall-
mounted using a wall-mounting kit, rack-mounted using
a 5-position space-saver shelf, or inserted in a
14-position power-redundant FlexPoint Powered
Chassis. When wall-mounting or shelf-mounting, attach
the power adapter unit.
Attach the unit’s RJ45 UTP via a category 5 cable to
a 100Base-Tx Fast Ethernet device.
Attach the units’s fiber via cable to a 100Base-Fx
Fast Ethernet device. The FlexPoint transmit (Tx)
must attach to the receive side on the other device;
the receive (Rx) must attach to the transmit.
Switch Settings:
“RJ45 Cross-Over” Switch: When connecting the UTP
to a hub or switch, set to “Straight-Through” (factory setting).
When connecting to a workstation, set it to “Cross-Over.”
“Auto-Negotiation/Manual” Switch: When in
“Manual” (factory setting), the FlexPoint operation is
selected by the “Full-Duplex/Half-Duplex” switch.
When in “Auto-Negotiation”, the FlexPoint automatically
selects full or half duplex operation depending on the
“Full-Duplex/Half-Duplex” switch position and the
features of the device connected to its UTP cable.
“Full-Duplex/Half-Duplex” Switch: When the “Auto-
Negotiation/Manual” switch is in “Manual” position,
the “Full-Duplex/Half-Duplex” switch determines the
type of duplex operation mode. When the “Auto-
Negotiation/Manual” switch is in “Auto-Negotiation”
position, the “Full-Duplex/Half-Duplex” switch
advertises its setting to the device connected to the
UTP port. When set to “Half-Duplex” (factory setting),
the FlexPoint will operate in half duplex. When set to
“Full-Duplex” the FlexPoint will operate in full-duplex
or half-duplex depending on the features supported
by the other device.
Half-duplex must be used when connecting to a hub.
Full-duplex can be used when connecting switches or
between a switch and a full-duplex workstation.
LED Indicators:
LED Color Description
Power On Yellow Power applied
Auto-Neg Green UTP switch is set to “Auto-Negotiation”
position.
Full-Duplex Green Full-Duplex selected.
Half-Duplex Green Half-Duplex selected.
Fiber Lk/Rx Green Solid: Link
Flashing: Data received.
Fiber Error Red Data errors detected on fiber.
UTP Lk/Rx Green Solid: Link,Flashing: Data received.
UTP Error Red Data errors detected on UTP.
LMC214A-SCP-R2
LMC214AE-SCP-R2
LMC214A-STP-R2
LMC214AE-STP-R2
LMC213A-SM-XLH-R2
LMC213AE-SM-XLH-R2
LMC213A-SM-SLH-R2
LMC213AE-SM-SLH-R2
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX
(outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a
week; Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation,
1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com

Transcripción de documentos

WARNING! Before plugging the Power Adapter to any wall outlet or AC power source, verify that the power on the unit is appropriate for your AC line voltage source. Overview and Description: LMC214A-SCP-R2 LMC214AE-SCP-R2 LMC214A-STP-R2 LMC214AE-STP-R2 LMC213A-SM-XLH-R2 LMC213AE-SM-XLH-R2 LMC213A-SM-SLH-R2 LMC213AE-SM-SLH-R2 LMC213A-MMSC-R2 LMC213AE-MMSC-R2 LMC213A-MMST-R2 LMC213AE-MMST-R2 LMC213A-SMSC-R2 LMC213AE-SMSC-R2 LMC213A-SMST-R2 LMC213AE-SMST-R2 FlexPoint™ 100Fx/Tx The FlexPoint 100Fx/Tx converts between Fast Ethernet 100Base-Fx fiber and 100Base-Tx twisted pair (RJ45 UTP) cabling. It operates in half-duplex (HD) or full-duplex (FD). The following multimode (MM) and single-mode (SM) models are described here: Model Fiber Type Distance LMC213A-MMSC-R2 LMC213AE-MMSC-R2 LMC213A-SMSC-R2 LMC213AE-SMSC-R2 LMC213A-MMST-R2 LMC213AE-MMST-R2 LMC213A-SMST-R2 LMC213AE-SMST-R2 LMC213A-SM-XLH-R2 LMC213AE-SM-XLH-R2 LMC213A-SM-SLH-R2 LMC213AE-SM-SLH-R2 LMC214A-SCP-R2 LMC214AE-SCP-R2 LMC214A-STP-R2 LMC214AE-STP-R2 1310nm,MM,SC 1310nm,MM,SC 1310nm,SM,SC 1310nm,SM,SC 1310nm,MM,ST 1310nm,MM,ST 1310nm,SM,ST 1310nm,SM,ST 1550nm, SM,SC 1550nm, SM,SC 1550nm, SM,SC 1550nm, SM,SC 1310nm,SM,SC 1310nm,SM,SC 1310nm,SM,ST 1310nm,SM,ST 2km / 1.2 mi. 2km / 1.2 mi. 28km / 17.4 mi. 28km / 17.4 mi. 2km / 1.2 mi. 2km / 1.2 mi. 25km / 15 mi. 25km / 15 mi. 85km / 52.8 mi. 85km / 52.8 mi. 110km / 68 mi. 110km / 68 mi. 58km / 35 mi. 58km / 35 mi. 58km / 35 mi. 58km / 35 mi. Installation and Configuration CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX SUPPORT (outside U.S. call 724-746-5500) INFORMATION FREE technical support 24 hours a day, 7 days a week; Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: [email protected] SPECIFICATIONS: „ Protocol: IEEE 802.3, 100Base-Fx, 100Base-Tx „ Connectors and Cables: „ „ „ „ Twisted Pair UTP: Fiber: Multimode: Single-mode: Supported Distances: Twisted Pair UTP: MM 1310nm fiber: SM 1310nm fiber,STD: SM 1310nm fiber,EXT: SM 1550nm XLH fiber: SM 1550nm SLH fiber: Power: Temperature: Humidity: RJ45, Category 5 or higher SC or ST 50/125, 62.5/125, 100/140µm 9/125µm Half-Duplex Full-Duplex 100m / 328ft. 100m/328 ft. 412m/1,350ft. 2 km/1.2 mi. 412m/1,350ft. 28km/17.4 mi. 412m/1,350ft. 58km/35 mi. 412m/1,350ft. 85km/52.8 mi. 412m/1,350ft. 110km/68 mi. 9VDC / 500 mA 0 to 40 degrees C 0-90% (non-condensing) Power Adapter Notice: 1. When used in a stand-alone configuration, this product is intended to be used only with a Listed Direct Plug-In Power Unit marked “Class 2” and rated at 9Vdc, 1 Amp. 2. This product should always be used only with its enclosed Power Unit. TRADEMARKS All applied-for and registered trademarks are the property of their respective owners. FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to be cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numéirques de las classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada. Mounting and Cable Attachment: The FlexPoint 100Fx/Tx can be individually wallmounted using a wall-mounting kit, rack-mounted using a 5-position space-saver shelf, or inserted in a 14-position power-redundant FlexPoint Powered Chassis. When wall-mounting or shelf-mounting, attach the power adapter unit. Attach the unit’s RJ45 UTP via a category 5 cable to a 100Base-Tx Fast Ethernet device. Attach the units’s fiber via cable to a 100Base-Fx Fast Ethernet device. The FlexPoint transmit (Tx) must attach to the receive side on the other device; the receive (Rx) must attach to the transmit. Switch Settings: “RJ45 Cross-Over” Switch: When connecting the UTP to a hub or switch, set to “Straight-Through” (factory setting). When connecting to a workstation, set it to “Cross-Over.” “Auto-Negotiation/Manual” Switch: When in “Manual” (factory setting), the FlexPoint operation is selected by the “Full-Duplex/Half-Duplex” switch. When in “Auto-Negotiation”, the FlexPoint automatically selects full or half duplex operation depending on the “Full-Duplex/Half-Duplex” switch position and the features of the device connected to its UTP cable. NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedelstales que sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante. 8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra or superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación. 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u ostros aparatos (incluyendo amplificadores) que producen calor. 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precación debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 1. “Full-Duplex/Half-Duplex” Switch: When the “AutoNegotiation/Manual” switch is in “Manual” position, the “Full-Duplex/Half-Duplex” switch determines the type of duplex operation mode. When the “AutoNegotiation/Manual” switch is in “Auto-Negotiation” position, the “Full-Duplex/Half-Duplex” switch advertises its setting to the device connected to the UTP port. When set to “Half-Duplex” (factory setting), the FlexPoint will operate in half duplex. When set to “Full-Duplex” the FlexPoint will operate in full-duplex or half-duplex depending on the features supported by the other device. Half-duplex must be used when connecting to a hub. Full-duplex can be used when connecting switches or between a switch and a full-duplex workstation. LED Indicators: LED Power On Auto-Neg Color Description Yellow Power applied Green UTP switch is set to “Auto-Negotiation” position. Full-Duplex Green Full-Duplex selected. Half-Duplex Green Half-Duplex selected. Fiber Lk/Rx Green Solid: Link Flashing: Data received. Fiber Error Red Data errors detected on fiber. UTP Lk/Rx Green Solid: Link,Flashing: Data received. UTP Error Red Data errors detected on UTP. ©Copyright 1999-2003. Black Box Corporation. All rights reserved. 1000 Park Drive z Lawrence, PA 15055-1018 724-746-5500 z Fax 724-746-0746 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia. 16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo. 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o E: El aparto ha sido tirado o su cubierta ha sido dañada. 040-01005-R21 08/03 SPECIFICATIONS: „ Protocol: IEEE 802.3, 100Base-Fx, 100Base-Tx „ Connectors and Cables: „ „ „ „ Twisted Pair UTP: Fiber: Multimode: Single-mode: Supported Distances: Twisted Pair UTP: MM 1310nm fiber: SM 1310nm fiber,STD: SM 1310nm fiber,EXT: SM 1550nm XLH fiber: SM 1550nm SLH fiber: Power: Temperature: Humidity: RJ45, Category 5 or higher SC or ST 50/125, 62.5/125, 100/140µm 9/125µm Half-Duplex Full-Duplex 100m / 328ft. 100m/328 ft. 412m/1,350ft. 2 km/1.2 mi. 412m/1,350ft. 28km/17.4 mi. 412m/1,350ft. 58km/35 mi. 412m/1,350ft. 85km/52.8 mi. 412m/1,350ft. 110km/68 mi. 9VDC / 500 mA 0 to 40 degrees C 0-90% (non-condensing) TRADEMARKS All applied-for and registered trademarks are the property of their respective owners. FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to be cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numéirques de las classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada. Overview and Description: LMC214A-SCP-R2 LMC214AE-SCP-R2 LMC214A-STP-R2 LMC214AE-STP-R2 LMC213A-SM-XLH-R2 LMC213AE-SM-XLH-R2 LMC213A-SM-SLH-R2 LMC213AE-SM-SLH-R2 LMC213A-MMSC-R2 LMC213AE-MMSC-R2 LMC213A-MMST-R2 LMC213AE-MMST-R2 LMC213A-SMSC-R2 LMC213AE-SMSC-R2 LMC213A-SMST-R2 LMC213AE-SMST-R2 FlexPoint™ 100Fx/Tx The FlexPoint 100Fx/Tx converts between Fast Ethernet 100Base-Fx fiber and 100Base-Tx twisted pair (RJ45 UTP) cabling. It operates in half-duplex (HD) or full-duplex (FD). The following multimode (MM) and single-mode (SM) models are described here: Model Fiber Type Distance LMC213A-MMSC-R2 LMC213AE-MMSC-R2 LMC213A-SMSC-R2 LMC213AE-SMSC-R2 LMC213A-MMST-R2 LMC213AE-MMST-R2 LMC213A-SMST-R2 LMC213AE-SMST-R2 LMC213A-SM-XLH-R2 LMC213AE-SM-XLH-R2 LMC213A-SM-SLH-R2 LMC213AE-SM-SLH-R2 LMC214A-SCP-R2 LMC214AE-SCP-R2 LMC214A-STP-R2 LMC214AE-STP-R2 1310nm,MM,SC 1310nm,MM,SC 1310nm,SM,SC 1310nm,SM,SC 1310nm,MM,ST 1310nm,MM,ST 1310nm,SM,ST 1310nm,SM,ST 1550nm, SM,SC 1550nm, SM,SC 1550nm, SM,SC 1550nm, SM,SC 1310nm,SM,SC 1310nm,SM,SC 1310nm,SM,ST 1310nm,SM,ST 2km / 1.2 mi. 2km / 1.2 mi. 28km / 17.4 mi. 28km / 17.4 mi. 2km / 1.2 mi. 2km / 1.2 mi. 25km / 15 mi. 25km / 15 mi. 85km / 52.8 mi. 85km / 52.8 mi. 110km / 68 mi. 110km / 68 mi. 58km / 35 mi. 58km / 35 mi. 58km / 35 mi. 58km / 35 mi. Installation and Configuration CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX SUPPORT (outside U.S. call 724-746-5500) INFORMATION FREE technical support 24 hours a day, 7 days a week; Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: [email protected] Power Adapter Notice: 1. When used in a stand-alone configuration, this product is intended to be used only with a Listed Direct Plug-In Power Unit marked “Class 2” and rated at 9Vdc, 1 Amp. 2. This product should always be used only with its enclosed Power Unit. NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedelstales que sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante. 8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra or superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación. 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u ostros aparatos (incluyendo amplificadores) que producen calor. 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precación debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia. 16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo. 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o E: El aparto ha sido tirado o su cubierta ha sido dañada. WARNING! Before plugging the Power Adapter to any wall outlet or AC power source, verify that the power on the unit is appropriate for your AC line voltage source. “Full-Duplex/Half-Duplex” Switch: When the “AutoNegotiation/Manual” switch is in “Manual” position, the “Full-Duplex/Half-Duplex” switch determines the type of duplex operation mode. When the “AutoNegotiation/Manual” switch is in “Auto-Negotiation” position, the “Full-Duplex/Half-Duplex” switch advertises its setting to the device connected to the UTP port. When set to “Half-Duplex” (factory setting), the FlexPoint will operate in half duplex. When set to “Full-Duplex” the FlexPoint will operate in full-duplex or half-duplex depending on the features supported by the other device. Mounting and Cable Attachment: The FlexPoint 100Fx/Tx can be individually wallmounted using a wall-mounting kit, rack-mounted using a 5-position space-saver shelf, or inserted in a 14-position power-redundant FlexPoint Powered Chassis. When wall-mounting or shelf-mounting, attach the power adapter unit. Attach the unit’s RJ45 UTP via a category 5 cable to a 100Base-Tx Fast Ethernet device. Attach the units’s fiber via cable to a 100Base-Fx Fast Ethernet device. The FlexPoint transmit (Tx) must attach to the receive side on the other device; the receive (Rx) must attach to the transmit. Switch Settings: “RJ45 Cross-Over” Switch: When connecting the UTP to a hub or switch, set to “Straight-Through” (factory setting). When connecting to a workstation, set it to “Cross-Over.” “Auto-Negotiation/Manual” Switch: When in “Manual” (factory setting), the FlexPoint operation is selected by the “Full-Duplex/Half-Duplex” switch. When in “Auto-Negotiation”, the FlexPoint automatically selects full or half duplex operation depending on the “Full-Duplex/Half-Duplex” switch position and the features of the device connected to its UTP cable. 040-01005-R21 08/03 Half-duplex must be used when connecting to a hub. Full-duplex can be used when connecting switches or between a switch and a full-duplex workstation. LED Indicators: LED Power On Auto-Neg Color Description Yellow Power applied Green UTP switch is set to “Auto-Negotiation” position. Full-Duplex Green Full-Duplex selected. Half-Duplex Green Half-Duplex selected. Fiber Lk/Rx Green Solid: Link Flashing: Data received. Fiber Error Red Data errors detected on fiber. UTP Lk/Rx Green Solid: Link,Flashing: Data received. UTP Error Red Data errors detected on UTP. ©Copyright 1999-2003. Black Box Corporation. All rights reserved. 1000 Park Drive z Lawrence, PA 15055-1018 724-746-5500 z Fax 724-746-0746
  • Page 1 1
  • Page 2 2

Black Box LMC213A-SMST-R2 Manual de usuario

Categoría
Convertidores de medios de red
Tipo
Manual de usuario

en otros idiomas