Danby DAS180DBAHWDB El manual del propietario

Categoría
Acondicionadores de aire de sistema dividido
Tipo
El manual del propietario
DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9
DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840
OWNER’S MANUAL
MANUEL DU PROPRIÉTAIRE
MANUAL DEL PROPIETARIO
www.Danby.com
2019.12.17
DAS180DBAHWDB
FOR ANY QUESTIONS OR CONCERNS REGARDING INSTALLATION OR SERVICING OF THIS UNIT,
PLEASE CONTACT THE DEALER OR BUILDER WHO SOLD THE UNIT.
_____________________________________________________________________
POUR TOUTE QUESTION OU PRÉOCCUPATION CONCERNANT L’INSTALLATION OU L’ENTRETIEN
DE CET APPAREIL, VEUILLEZ CONTACTER LE REVENDEUR OU LE CONSTRUCTEUR QUI A VENDU
L’APPAREIL.
__________________________________________________________________
PARA CUALQUIER PREGUNTA O INQUIETUD RELACIONADA CON LA INSTALACIÓN O SERVICIO DE
ESTA UNIDAD, PÓNGASE EN CONTACTO CON EL DISTRIBUIDOR O CONSTRUCTOR QUE VENDIÓ LA
UNIDAD.
SPLIT AIR CONDITIONER
Installation Guide ............................................... 1 - 30
CLIMATISEUR DIVISÉ
Guide d’installation........................................... 31 - 60
AIRE ACONDICIONADO DIVIDIDO
Guía de instalación............................................ 61 - 90
1
SAVE THESE INSTRUCTIONS!
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAFETY PRECAUTIONS
Incorrect installation due to ignoring instructions
can cause serious damage or injury.
When connecting refrigerant piping, do not let
substances or gases other than the specifi ed
refrigerant enter the lines as this will lower the
unit’s capacity and can cause abnormally high
pressure in the refrigeration system, which can
lead to explosion or injury.
Installation must be performed by a certifi ed
HVAC technician. Defective installation can
cause water leakage, electrical shock or fi re.
In North America, installation must be performed
in accordance with the requirement of NEC and
CEC by authorized personnel only.
Contact an HVAC technician or the sales agent
for information on repair or maintenance of this
appliance.
Only use the included accessories, parts and
specifi ed parts for installation. Using non-
standard parts can cause water leakage,
electrical shock, fi re and can cause the unit to
fail.
Install the appliance in a fi rm location that can
support the unit’s weight. If the chosen location
cannot support the appliance’s weight, or if
the installation is not completed properly, the
appliance may fall and cause serious injury or
damage.
For all electrical work, follow all local and
national wiring standards and regulations and
this manual. You must use an independent circuit
and single outlet to supply power. Do not connect
other appliances to the same outlet. Insuffi cient
electrical capacity or defects in electrical work
can cause electrical shock or fi re.
For all electrical work, use all specifi ed cables.
Connect cables tightly and clamp them securely
to prevent external forces from damaging the
terminal. Improper electrical connections can
overheat and cause electrical shock or fi re.
All wiring must be correctly arranged to ensure
that the control board can close properly. If the
control board cover is not closed properly, it
can lead to corrosion and cause the connection
points on the terminal to overheat, catch fi re or
cause electrical shock.
In certain functional environments, such as
kitchens, server rooms, etc., the use of specially
designed air conditioning units is highly
recommended.
This appliance is not intended for use by persons
(including children) whose physical, sensory or
metal capabilities may be different or reduced, or
who lack experience or knowledge, unless such
persons receive supervision or training to operate
the appliance by a person responsible for their
safety.
Do not install the appliance in a location that
may be exposed to combustible gas leaks.
If combustible gas accumulates around the
appliance, it may cause fi re.
Do not operate this appliance in a wet room
such as a bathroom or laundry room. Too
much exposure to water can cause electrical
components to short circuit.
The appliance must be properly grounded or
electric shock can occur.
Install drainage piping according to the
instructions in this manual. Improper drainage
may cause water damage.
NOTE ABOUT FLUORINATED GASES
This appliance contains fl uorinated gasses. For
specifi c information on the type and amount of
gas, refer to the relevant label on the appliance
itself.
Installation, service, maintenance and repair of
this appliance must be performed by a certifi ed
HVAC technician.
Uninstallation and recycling must be performed
by a certifi ed HVAC technician.
If the appliance has a leak detection system
installed, it must be checked for leaks at least
every 12 months. When the appliance is
checked for leaks, proper record keeping of all
checks is strongly recommended.
2
ACCESSORIES
The air conditioning system comes with the following accessories. Use all of the installation parts and
accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock,
re or may cause the equipment to fail.
Part Image Quantity
Mounting plate 2
Mounting plate fi xing screw ST3.9 x 25
10
Clip anchor 10
Remote control 2
Dry battery AAA.LR03 4
Seal 2
Drain joint
2
INSTALLATION INSTRUCTIONS
3
INSTALLATION SUMMARY
Note: Illustrations in this manual are for explanatory purposes only. The actual shape of the appliance may
be slightly different. The actual shape shall prevail.
Wall Mounting Plate
Front Panel
Louver
Power Cable
Drainage Pipe
Signal Cable
Refrigerant Pipe
Remote Control
Outdoor Unit
Power Cable
Functional Filter
On Front of Main Filter
INSTALLATION INSTRUCTIONS
Note: The model DAS180DBAHWDB can be attached to multiple indoor units. See the next page for
details.
4
INSTALLATION SUMMARY
When installing multiple indoor units to a single outdoor unit, ensure that the length of the refrigerant pipe
and the drop height between the indoor and outdoor units meet the following requirements:
INSTALLATION INSTRUCTIONS
49ft (15m)
49ft (15m)
32.8ft (10m)
Outdoor Unit
Outdoor Unit
Outdoor Unit
Indoor Unit
Indoor units that can be used in combination Number of connected units 1 - 5 units
Compressor stop/start frequency Stop time 3 minutes or more
Power source voltage
Voltage fl uctuation within ± 10% of rated voltage
Voltage drop during start within ± 15% of rated voltage
Interval unbalance within ± 3% of rated voltage
Units are in meters/feet 1 drive 2 1 drive 3 1 drive 4 1 drive 5
Max. length for all rooms 40/131 60/197 80/262 80/262
Max. length for one indoor unit 25/82 30/98 35/115 35/115
Max. height difference between indoor and outdoor 15/49 15/49 15/49 15/49
Max. height difference between indoor units 10/33 10/33 10/33 10/33
5
INSTALLATION SUMMARY - INDOOR UNIT
INSTALLATION INSTRUCTIONS
6
INSTALLATION SUMMARY - INDOOR UNIT
INSTALLATION INSTRUCTIONS
7
INDOOR UNIT INSTALLATION
Before installing the indoor unit, refer to the label on the product box to ensure that the model number on the
indoor unit matches the model number on the outdoor unit. The indoor unit model number will end with a “-I”
and the outdoor unit model number will end with a “-O”, otherwise they should be identical.
Step 1: Select Installation Location
Proper installation locations meet the following standards:
Good air circulation.
• Convenient drainage.
Noise from the unit will not be disturbing.
Firm and solid location that will not vibrate.
Strong enough to support the weight of the unit.
At least 1 m (3 feet) away from all other electrical devices, such as televisions, radios and computers,
which could impact the infrared remote signal.
Do not install the indoor unit in locations that have the following:
Near any source of heat, steam or combustible gas.
Near fl ammable items such as curtains or clothing.
Near any obstacle that might block air circulation.
Near any doorway.
In direct sunlight.
Refer to the below illustration to ensure proper distance from surrounding walls and ceiling:
INSTALLATION INSTRUCTIONS
8
Step 2: Attach Mounting Plate To Wall
The mounting plate is the device that attaches the indoor unit on the wall.
1. Remove the screw that attaches the mounting plate to the back of the indoor unit.
2. Place the mounting plate against the wall in the location where the indoor unit will be installed.
3. Drill holes for the mounting screws, ensuring that the screws enter wall studs that can support the weight
of the unit.
4. Secure the mounting plate to the wall with the provided screws. Ensure that the mounting plate is fl at
against the wall.
Note: If the wall is made of brick, concrete or similar material, drill 5 mm (0.2 in) diameter holes in the wall
and insert the provided sleeve anchors. Secure the mounting plate to the wall by tightening the screws into
the clip anchors.
Mounting Plate Dimensions
Different models have different mounting plates. To ensure
that there is ample room to mount the indoor unit, check
the diagrams below which show the two different types of
mounting plates along with the following dimensions:
Width of mounting plate.
Height of mounting plate.
Width of indoor unit relative to mounting plate.
Height of indoor unit relative to mounting plate.
Recommended position of wall hole, both to the left and
right of the indoor unit.
Relative distance between screw holes.
INSTALLATION INSTRUCTIONS
10.1 cm (4”)
17.9 cm (7.05”)
13.6 cm (5.35”)
3.7 cm (1.45”)
29 cm (11.4”)
4.9 cm (1.95”)
Right rear wall
hole 6.5 cm (2.5”)
Indoor unit outline
72.2 cm (28.45”)
4.9 cm (1.95”)
22.8 cm (8.98”)
22.9 cm (9.01”)
40.1 cm (15.78”)
12.6 cm (4.96”)
4.2 cm (1.65”)
29.7 cm (11.7”)
Left rear wall
hole 6.5 cm (2.5”)
Left rear wall
hole 6.5 cm (2.5in)
Right rear wall
hole 6.5 cm (2.5”)
Indoor unit outline
80.2 cm (31.6”)
5.8 cm (2.28”)
4.7 cm (1.85”)
Model B
Model A
34.8 cm (13.7”)
9
Step 3: Drill Wall Hole For Connective Piping
A hole must be drilled through the wall to the outside to accommodate the refrigerant piping, the drainage
pipe and the signal cable that will connect the indoor and outdoor units.
1. Determine the location of the wall hole based on the position of the mounting plate. See Step 2 for
mounting plate dimensions.
2. The wall hole should have a 65 mm (2.5 in) diameter and it should be drilled on a downward angle to
facilitate drainage. The outdoor end of the hole should be lower than the indoor end of the hole by 5 - 7
mm (0.2 - 0.275 in).
3. Place the protective wall cuff in the hole. This will protect the edges of the hole and will help seal the
hole once the installation is complete.
Note: When drilling the wall hole, make sure to avoid wires, plumbing and other sensitive components that
could be within the wall.
INSTALLATION INSTRUCTIONS
10
Step 4: Prepare Refrigerant Piping
The refrigerant piping is inside an insulating sleeve attached to the back of the
unit. The piping must be prepared before passing it through the hole in the wall.
Refer to the Refrigerant Piping Connection section for detailed instructions on
pipe fl aring and fl are torque requirements, etc.
1. Based on the position of the wall hole relative to the mounting plate, choose
the side from which the piping will exit the unit.
2. If the wall hole is behind the unit, leave the knock out panel in place. If the
wall hole is to the side of the indoor unit, remove the plastic knock out panel
from the side of the unit. This will create a slot through which the piping can
exit the unit. Use needle nose pliers if the plastic panel is diffi cult to remove.
3. Use scissors to cut down the length of the insulating sleeve to reveal
approximately 15 cm (6 in) of the refrigerant piping. This serves two
Knock out panel
purposes:
To facilitate the Refrigerant Piping Connection process
To facilitate gas leaks checks and allow a check for dents in the pipe
4. If existing connective piping is already embedded in the wall, proceed directly to Step 5: Connect The
Drain Hose. If there is no embedded piping, connect the indoor unit’s refrigerant piping to the connective
piping that will join the indoor and outdoor units.
5. Based on the position of the wall hole relative to the mounting plate, determine the necessary angle of
the piping. Grip the refrigerant piping at the base of the bend.
6. Slowly, with even pressure, bend the piping toward the wall hole. Do not dent or damage the pipe
during the process.
Note on Piping Angle
Refrigerant piping can exit the indoor unit from four different angles:
• Left-hand side
• Left rear
• Right-hand side
• Left rear
CAUTION
Be extremely careful not to dent or damage the piping
while bending them away from the unit. Any dents in
the piping will affect the unit’s performance.
INSTALLATION INSTRUCTIONS
11
Step 5: Connect the Drain Hose
By default, the drain hose is attached to the left-hand side of the unit, when facing the back of the unit. It can
also be attached to the right-hand side.
1. To ensure proper drainage, attach the drain hose on the same side of the unit as the refrigerant piping.
2. Attach the drain hose extension (purchased separately) to the end of the drain hose.
3. Wrap the connection point fi rmly with Tefl on tape to ensure a good seal and prevent leaks.
4. For the portion of the drain hose that will remain indoors, wrap it with foam pipe insulation to prevent
condensation.
5. Remove the air fi lter and pour a small amount of water into the drain pan to make sure that water fl ows
from the unit smoothly.
Note on Drain Hose Placement
Do not kink the drain hose.
Do not create a water trap.
Do not put the end of the drain hose in water or a container that will collect water.
Note: To prevent unwanted leaks, plug the unused drain hole with the provided rubber plug.
See below for examples of correct drain hose installation:
INSTALLATION INSTRUCTIONS
12
BEFORE PERFORMING ELECTRICAL WORK, READ THESE REGULATIONS
1. All wiring must comply with local and national electrical codes and must be installed by a licensed
electrician.
2. All electrical connections must be made according to the Electrical Connection Diagram located on the
panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power supply, stop work immediately. Explain your reasoning to
the client and refuse to install the unit until the safety issue is resolved.
4. Power voltage should be within 90 - 100% of rated voltage. Insuffi cient power supply can cause
malfunction, electrical shock or fi re.
5. If connecting power to fi xed wiring, install a surge protector and main power switch with a capacity of
1.5 times the maximum current of the unit.
6. If connecting power to fi xed wiring, a switch or circuit breaker that disconnects all poles and has a
contact separation of at least 3 mm (1.8 in) must be incorporated in the fi xed wiring. The qualifi ed
technician must use an approved circuit breaker or switch.
7. Only connect the unit to an individual branch circuit outlet. Do not connect another appliance to that
outlet.
8. Make sure to properly ground the appliance.
9. Every wire must be fi rmly connected. Loose wiring can cause the terminal to overheat, resulting in product
malfunction and possible fi re.
10. Do not let wires touch or rest against the refrigerant tubing, the compressor or any moving parts within
the unit.
WARNING
BEFORE PERFORMING ANY ELECTRICAL WIRING WORK,
TURN OFF THE MAIN POWER TO THE SYSTEM.
WARNING
All wiring must be performed in accordance with the wiring
diagram located on the inside of the indoor unit’s wire cover.
Do not mix up live and null wires. This is dangerous and can
cause the appliance to malfunction.
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Connect the wiring to the terminals as identifi ed with their respective matched numbers on the terminal block
of the indoor and outdoor units. For example, see the following US models: Terminal L1(A) on the outdoor
unit must connect with terminal L1 on the indoor unit.
Run the main power cord through the lower line outlet of the cord clamp.
One-two mo
d
e
l
s:
Model A
Model E Model F Model G
Model B Model C Model D
13
14
Step 6: Connect the Signal Cable
The signal cable enables communication between the indoor and outdoor units. You must fi rst choose the
right cable size before preparing it for connection.
Cable types:
Indoor Power Cable (if applicable): H05W-F or H05V2V2-F
Outdoor Power Cable: H07RN-F
Signal Cable: H07RN-F
Minimum Cross Sectional Area of
Power and Signal Cables
Appliance Amps (A) AWG
10 18
13 16
18 14
25 12
30 10
CHOOSE THE RIGHT SIZE CABLE
The size of the power supply cable, signal cable, fuse and
switch needed is determined by the maximum current in the unit.
The maximum current is indicated on the rating plate located on
the side panel of the unit. Refer to this rating plate to choose the
right cable, fuse and switch.
Take Note of Fuse Specifi cations
The air conditioner circuit board (PCB) is designed with a fuse to provide over current protection. The
specifi cations of the fuse are printed on the circuit board, such as: T3.15A/250VAC, T5A/250VAC, etc.
1. Prepare the cable for connection:
a. Using wire strippers, strip the rubber jacket from both ends of the signal cable to reveal
about 40 mm (1.57 in) of the wires inside.
b. Strip the insulation from the ends of the wires.
c. Using wire crimper, crimp u-type lugs on the ends of the wires.
2. Open the front panel of the indoor unit.
3. Using a screwdriver, open the wire box cover on the right side of the unit. This will reveal the terminal
block.
4. Unscrew the cable clamp below the terminal block and place it to the side.
5. Facing the back of the unit, remove the plastic panel on the bottom left-hand side.
6. Feed the signal wire through this slot, from the back of the unit to the front.
7. Facing the front of the unit, match the wire colours with the labels on the terminal block, connect the u-lug
and fi rmly screw each wire to its corresponding terminal.
8. After checking to make sure every connection is secure, use the cable clamp to fasten the signal cable to
the unit. Screw the cable clamp down tightly.
9. Replace the wire cover on the front of the unit and the plastic panel on the back.
The wiring diagram is
located on the inside of
the wire cover on the
indoor unit.
Note: Pay attention to the live
wire. While crimping wires,
make sure to distinguish the Live
(“L”) Wire and other wires.
INSTALLATION INSTRUCTIONS
15
Step 7: Wrap piping and cables
Before passing the piping, drain hose and the signal cable through the wall hole, bundle them together to
save space, protect them and insulate them.
1. Bundle the drain hose, refrigerant pipes and signal cable.
Note: Ensure that the drain hose is at the bottom of the bundle. Putting the drain hose at the top of the bundle
can cause the drain pan to overfl ow, which can lead to fi re or water damage.
2. Using adhesive vinyl tape, attach the drain hose to the underside of the refrigerant pipes.
3. Using insulation tape, wrap the signal wire, refrigerant pipes and drain hose tightly together.
Note: While bundling these items together, do not intertwine or cross the signal cable with any other wiring.
Note: When wrapping the bundle, keep the ends of piping unwrapped. Access is required to test for leaks
at the end of the installation process.
INSTALLATION INSTRUCTIONS
16
Step 8: Mount the Indoor Unit
If new connective piping was installed to the outdoor unit, complete the following:
1. If the refrigerant piping has already been passed through the wall, proceed to step 4.
2. Otherwise, double check that the ends of the refrigerant pipes are sealed to prevent dirt or foreign
materials from entering the pipes.
3. Slowly pass the wrapped bundle of refrigerant pipes, drain hose and signal wire through the hole in the
wall.
4. Hook the top of the indoor unit on the upper hook of the mounting plate.
5. Check that the unit is hooked fi rmly on mounting by applying slight pressure to the left and right-hand
sides of the unit. The unit should not jiggle or shift.
6. Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps
onto the hooks along the bottom of the mounting plate.
7. Check that the unit is fi rmly mounted by applying slight pressure to the left and right-hand sides of the
unit.
If refrigerant piping is already embedded in the wall, complete the following:
1. Hook the top of the indoor unit on the upper hook of the mounting plate.
2. Use a bracket or wedge to prop up the unit, allowing enough room to connect the refrigerant piping,
signal cable and drain hose.
3. Connect the drain hose and refrigerant piping. Refer to the Refrigerant Piping Connection section for
more information.
4. Keep the pipe connection point exposed to perform the leak test. Refer to the Electrical Checks and Leak
Checks section for more information.
5. After the leak test, wrap the connection point with insulation tape.
6. Remove the bracket or wedge that is propping up the unit.
7. Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps
onto the hooks along the bottom of the mounting plate.
Unit is Adjustable
The hooks on the mounting plate are smaller than the holes on the back of the unit. The unit can be adjusted
left or right by approximately 30 - 50 mm (1.25 - 1.95 in) depending on the model.
INSTALLATION INSTRUCTIONS
17
OUTDOOR UNIT INSTALLATION
Step 1: Select installation location
Before installing the outdoor unit, choose an appropriate location for the unit. Proper installation locations
meet the following requirements:
Good air circulation and ventilation.
Firm and solid; the location can support the unit and will not vibrate.
Noise from the unit will not be disturbing.
The unit will be protected from prolonged periods of direct sunlight, rain or snow.
The location must meet the special requirements outlined below:
Do not install the unit in the following locations:
Near obstacles that will block air inlets or outlets.
Near a public street, crowded areas or where noise from the unit will disturb others.
Near animals or plants that could be harmed by hot air discharge.
Near any source of combustible gas.
In a location that is exposed to large amounts of dust.
In a location that is exposed to large amounts of salty air.
Special Considerations For Extreme Weather
If the unit is exposed to heavy wind, install the unit so that the air outlet fan is at a 90° angle to the direction
of the wind. If needed, build a barrier in front of the unit to protect it from the wind.
If the unit is exposed to heavy rain or snow, build a shelter above the unit to protect it. Be careful not to
obstruct air fl ow around the unit.
If the unit is exposed to salty air, use an outdoor unit that is specially designed to resist corrosion.
INSTALLATION INSTRUCTIONS
18
Step 2: Install the drain joint
Before bolting the outdoor unit in place, install the drain joint at the bottom of the unit. There are two types of
drain joint depending on the type of unit.
1. Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit.
2. Insert the drain joint into the hole in the base pan of the unit.
3. Rotate the drain joint 90° until it clicks in place facing the front of the unit.
4. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during
heating mode.
The base hole for the drain joint can be found on the bottom of the unit.
Note For Cold Climates
In cold climates, ensure that the drain hose is positioned as close to vertical as possible to encourage swift
water drainage. If water drains too slowly it can freeze inside the drain hose and fl ood the unit.
INSTALLATION INSTRUCTIONS
19
Step 3: Anchor the outdoor unit
The outdoor unit can be anchored to the ground or to a wall-mounted bracket.
The following is a list of outdoor unit sizes and the distance between their mounting feet. Prepare the
installation base of the unit according to the dimensions and images below.
If the unit will be ground mounted, follow the below instructions:
1. Mark the positions for four expansion bolts based on dimensions in the unit mounting dimensions chart.
2. Pre-drill holes for expansion bolts.
3. Clean concrete dust away from holes.
4. Place a nut on the end of each expansion bolt.
5. Hammer expansion bolts into the pre-drilled holes.
6. Remove the nuts from the expansion bolts and place outdoor unit on the bolts.
7. Put washer on each expansion bolt and then replace the nuts.
8. Using a wrench, tighten each nut until snug.
WARNING
When drilling into concrete,
eye protection should be
worn at all times.
If the unit will be wall mounted, follow the below instructions:
1. Mark the positions of the bracket holes based on dimensions in the unit mounting dimensions chart.
2. Pre-drill holes for expansion bolts.
3. Clean concrete dust away from holes.
4. Place a washer and a nut on the end of each expansion bolt.
5. Thread the expansion bolts through the holes on the mounting brackets, put mounting brackets in position
and hammer the expansion bolts into the wall.
6. Check that the mounting brackets are level.
7. Carefully lift the unit and place its mounting feet on the brackets.
8. Bolt the unit fi rmly to the brackets.
Note: To reduce vibrations and noise of a wall-mounted unit, install the unit with rubber gaskets.
Unit Mounting Dimensions Chart
Model Number Unit Dimensions (W x H x D)
Distance A
(mm / in)
Distance B
(mm / in)
DAS180DBAHWDB 922x715x379 (36.3”x28.2”x14.9”) 540 (21.26”) 350 (13.8”)
INSTALLATION INSTRUCTIONS
20
Step 4: Connect the signal and power cables
The outdoor unit’s terminal block is protected by an electrical wiring cover on the side of the unit. A
comprehensive wiring diagram is printed on the inside of the wiring cover.
Cable Types:
Indoor Power Cable (if applicable): H05V-F or H05V2-F
Outdoor Power Cable: H07RN-F
Signal Cable: H07RN-F
1. Prepare the cable for connection:
a. Using wire strippers, strip the rubber jacket from both ends of the signal cable to reveal
about 40 mm (1.57 in) of the wires inside.
b. Strip the insulation from the ends of the wires.
c. Using wire crimper, crimp u-type lugs on the ends of the wires.
2. Unscrew the electrical wiring cover and remove it.
3. Unscrew the cable clamp below the terminal block and place it to the side.
4. Match the wire colours and labels with the labels on the terminal block and fi rmly screw the u-lug of each
wire to its corresponding terminal.
5. After checking to make sure every connection is secure, loop the wires around to prevent rain water from
owing into the terminal.
6. Using the cable clamp, fasten the cable to the unit. Screw the cable clamp down tightly.
7. Insulate unused wires with PVC electrical tape. Arrange them so that they do not touch any electrical or
metal parts.
8. Replace the wire cover on the side of the unit and screw it into place.
Minimum Cross Sectional Area of
Power and Signal Cables
Appliance Amps (A) AWG
10 18
13 16
18 14
25 12
30 10
WARNING
All wiring must be performed in accordance with the
wiring diagram located on the inside of the outdoor unit’s
wire cover. Do not mix up live and null wires. This is
dangerous and can cause the appliance to malfunction.
The wiring diagram is
located on the inside of
the wire cover on the
outdoor unit.
Note: Pay attention to the
live wire. While crimping
wires, make sure to
distinguish the Live (“L”)
Wire and other wires.
INSTALLATION INSTRUCTIONS
21
REFRIGERANT PIPING CONNECTION
The length of the refrigerant piping will affect the performance and energy ef ciency of the unit. Nominal
effi ciency is tested on units with a pipe length of 5 m (16.5 ft).
CONNECTION INSTRUCTIONS - REFRIGERANT PIPING
Step 1: Cut pipes
When preparing refrigerant pipes, take extra care to cut and fl are them properly. This will ensure ef cient
operation and minimize the need for future maintenance.
1. Measure the distance between the indoor and outdoor units.
2. Using a pipe cutter, cut the pipe a little longer than the measured distance.
3. Make sure that the pipe is cut at a perfect 90°.
Note: Do not damage, dent or
deform the pipe while cutting.
This will drastically reduce the
heating effi ciency of the unit.
Step 2: Remove burrs
Burrs can affect the air-tight seal of the
refrigerant piping connection. Burrs must be
completely removed.
1. Hold the pipe at a downward angle to
prevent burrs from falling into the pipe.
2. Using a reamer or de-burring tool,
remove all burrs from the cut section of
the pipe.
INSTALLATION INSTRUCTIONS
22
Step 3: Flare pipe ends
Proper fl aring is essential to achieve an airtight seal.
1. After removing burrs from the cut pipe, seal the ends with PVC tape to prevent foreign materials from
entering the pipe.
2. Sheath the pipe with insulating material.
3. Place fl are nuts on both ends of the pipe. Make sure they are facing in the right direction as they cannot
be removed or adjusted after fl aring.
4. Remove the PVC tape from the ends of the pipe when ready to perform fl aring work.
5. Clamp fl are form on the end of the pipe. The end of the pipe must extend beyond the edge of the fl are
form in accordance with the dimensions shown in the table and image below.
6. Place fl aring tool onto the form.
7. Turn the handle of the fl aring tool clockwise until the pipe is fully fl ared.
8. Remove the fl aring tool and fl are form and then inspect the end of the pipe for cracks and even fl aring.
PIPING EXTENSION BEYOND FLARE FORM
Outer Pipe Diameter (mm) Dimension A Minimum (mm) Dimension A Maximum (mm)
Ø 6.35 (Ø 0.25 in) 0.7 (0.0275 in) 1.3 (0.05 in)
Ø 9.52 (Ø 0.375 in) 1.0 (0.04 in) 1.6 (0.063 in)
Ø 12.7 (Ø 0.5 in) 1.0 (0.04 in) 1.8 (0.07 in)
Ø 16 (Ø 0.63 in) 2.0 (0.078 in) 2.2 (0.086 in)
INSTALLATION INSTRUCTIONS
23
Step 4: Connect pipes
When connecting refrigerant pipes, be careful not to use excessive torque or
to deform the piping in any way. Connect the low pressure pipe fi rst and then
connect the high pressure pipe.
Note: When bending connective refrigerant piping, the minimum bending radius
is 10 cm (3.9 in).
CONNECTING PIPING TO INDOOR UNIT
1. Align the center of the two pipes that will be connected.
2. Tighten the fl are nut as tightly as possible by hand.
3. Using a spanner, grip the nut on the unit tubing.
4. While fi rmly gripping the nut on the unit tubing, use a torque wrench to tighten the fl are nut according
to the torque values in the torque requirements table below. Loosen the fl aring nut slightly, then tighten
again.
TORQUE REQUIREMENTS
Outer Diameter of Pipe (mm) Tightening Torque (N•cm) Add. Tightening Torque (N•m)
Ø 6.35 (Ø 0.25 in) 1,500 (11 lb•ft) 1,600 (11.8 lb•ft)
Ø 9.52 (Ø 0.375 in) 2,500 (18.4 lb•ft) 2,600 (19.18 lb•ft)
Ø 12.7 (Ø 0.5 in) 3,500 (25.8 lb•ft) 3,600 (26.55 lb•ft)
Ø 16 (Ø 0.63 in) 4,500 (19 lb•ft) 4,700 (34.67 lb•ft)
Excessive force can break the nut or
damage the refrigerant piping. Do not
exceed the torque requirements shown
in the table below.
INSTALLATION INSTRUCTIONS
24
CONNECTING PIPING TO OUTDOOR UNIT
1. Unscrew the cover from the packed valve on the side of the outdoor unit.
2. Remove protective caps from ends of valves.
3. Align fl ared pipe end with each valve and tighten the fl are nut as tightly as possible by hand.
4. Using a spanner, grip the body of the valve. Do not grip the nut that seals the service valve.
5. While fi rmly gripping the body of the valve, use a torque wrench to tighten the fl are nut according to the
correct torque values.
6. Loosen the fl aring nut slightly, then retighten again.
7. Repeat steps 3 to 6 for the remaining pipe.
INSTALLATION INSTRUCTIONS
25
AIR EVACUATION
Preparations and Precautions
Air and foreign matter in the refrigerant circuit can cause abnormal rises in pressure, which can damage the
air conditioner, reduce its ef ciency and cause injury. Use a vacuum pump and manifold gauge to evacuate
the refrigerant circuit, removing any non-condensible gas and moisture from the system.
Evacuation should be performed upon initial installation and when the unit is relocated.
Before performing the evacuation:
Check to make sure that both the high pressure and low pressure pipes between the indoor and outdoor
units are installed correctly.
Check to make sure all wiring is connected properly.
Evacuation Instructions
Before using the manifold gauge and vacuum pump, read their operation manuals to ensure they are used
correctly.
INSTALLATION INSTRUCTIONS
26
Evacuation Instructions
1. Connect the charge hose of the manifold gauge to the service port on the outdoor unit’s low pressure
valve.
2. Connect another charge hose from the manifold gauge to the vacuum pump.
3. Open the low pressure side of the manifold gauge. Keep the high pressure side closed.
4. Turn on the vacuum pump to evacuate the system.
5. Run the vacuum for at least 15 minutes or until the compound meter reads -76cmHG (-10
5
Pa).
6. Close the low pressure side of the manifold gauge and turn off the vacuum pump.
7. Wait for 5 minutes then check that there has been no change in the system pressure.
8. If there is a change in the system pressure, refer to the Gas Leak Check section for information on how
to check the system for leaks. If there is no change in the system pressure, unscrew the cap from the
packaged high pressure valve.
9. Insert hexagonal wrench into the packed high pressure valve and open the valve by turning the wrench
in a 1/4 clockwise turn. Listen for gas to exit the system, then close the valve after 5 seconds.
10. Watch the pressure gauge for 1 minute to ensure there is no change in the pressure. The pressure
gauge should read slightly higher than atmospheric pressure.
11. Remove the charge hose from the service port.
12. Using a hexagonal wrench, fully open both the high pressure and low pressure valves.
13. Tighten valve caps on all three valves, (service port, high pressure and low pressure) by hand.
Tighten further with a torque wrench if necessary.
WARNING
DO NOT MIX
REFRIGERANT TYPES
INSTALLATION INSTRUCTIONS
Additional Refrigerant Per Pipe Length
Connective Pipe
Length (m)
Air Purging
Method
Additional Refrigerant
< Standard Pipe
Length
Vacuum Pump N/A
> Standard Pipe
Length
Vacuum Pump
Liquid Side: Ø 6.35 (ø 0.25 in)
Inverter R410a:
(Pipe Length - SPL) x 15g/m
(Pipe Length - SPL) x 0.16oZ/ft
Liquid Side: Ø 9.52 (ø 0.375 in)
Inverter R410a:
(Pipe Length - SPL) x 30g/m
(Pipe Length - SPL) x 0.32oZ/ft
27
Note: Open valve stems gently. When opening valve stems, turn the hexagonal wrench until it hits against
the stopper. Do not try to force the valve to open further.
Note: Some systems require additional charging depending on pipe lengths. The standard pipe length varies
according to local regulations. For example, in North America, the standard pipe length is 7.5 m (25 feet).
In other areas, the standard pipe length is 5 m (16 feet). The additional refrigerant to be charged can be
calculated using the formula in the below chart.
SPL = Standard Pipe Length
INSTALLATION INSTRUCTIONS
28
ELECTRICAL AND GAS LEAK CHECKS
Electrical Safety Checks
After installation, confi rm that all electrical wiring is installed in accordance with local and national
regulations and according to the installation manual.
Check Grounding Work
Before completing a test run, measure grounding resistance by visual detection and with grounding
resistance tester. Grounding resistance must be less than 4.
Check for Electrical Leakage
During the test run, use an electroprobe and multimeter to perform a comprehensive electrical leakage test.
If electrical leakage is detected, turn off the unit immediately and call a licensed electrician to fi nd and
resolve the cause of the leakage.
Gas Leak Checks
There are two acceptable methods of checking for gas leaks.
Soap and Water Method
Using a soft brush, apply soapy water or liquid detergent to all pipe connection points on the indoor and
outdoor units. The presence of bubbles indicates a leak.
Leak Detector Method
If using a leak detector, refer to the device’s operation manual for proper usage instructions.
Note: After completing gas leak checks, confi rm that all piping connection points do not leak and make sure
to replace the valve cover on the outdoor unit.
WARNING
ALL WIRING MUST COMPLY WITH LOCAL
AND NATIONAL ELECTRICAL CODES
AND MUST BE INSTALLED BY A LICENSED
ELECTRICIAN.
INSTALLATION INSTRUCTIONS
TEST RUN
Before completing a test run, make sure to complete all electrical safety checks and gas leak checks.
Confi rm that the unit’s electrical system is safe and operating properly. Check all fl are nut connections and
confi rm that the system is not leaking.
Test Run Instructions
1. Connect power to the unit.
2. Press the ON/OFF button on the remote to turn the unit on.
3. Press the MODE button to scroll through the following functions:
COOL - select lowest possible temperature
HEAT - select highest possible temperature
4. Allow each function to run for 5 minutes and perform the following checks:
No electrical leakage
Unit is properly grounded
All electrical terminals are properly covered
Indoor and outdoor units are solidly installed
All pipe connection points do not leak
Water drains properly from the drain hose
All piping is properly insulated
Unit performs COOL function properly
Unit performs HEAT function properly
Indoor unit louvers rotate properly
Indoor unit responds to the remote control
IMPORTANT: During operation, the pressure of the refrigerant circuit will increase. This may reveal leaks that
were not present during the initial leak check. Take time during the test run to double check that all refrigerant
pipe connection points do not have leaks.
5. After the test run is successfully complete, use the remote control to return the unit to normal operating
temperature. Using insulation tape, wrap the indoor refrigerant pipe connections that were left uncovered
during the indoor unit installation process.
Test Run in Low Temperature
If the ambient temperature is below 17
o
C (62.6 F), the COOL function will not run when using the remote
control. In this instance, use the manual control button to test the COOL function.
1. Lift the front panel of the indoor unit and raise it until it clicks into place.
2. The manual control button is located on the right-hand side of the unit. Press it two times to select the
COOL function.
3. Perform test run as normal.
Disposal Guidelines
This appliance contains refrigerant and other potentially hazardous materials. When disposing of this ap-
pliance, the law requires special collection and treatment. Do not dispose of this appliance as household
waste or unsorted municipal waste.
29
INSTALLATION INSTRUCTIONS
LIMITED IN-HOME APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating
conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter
“Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
First Year
During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the ORIGINAL purchaser.
To obtain
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance
Service
requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at
their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below.
Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service
must be performed by a qualied service technician.
If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all
obligations of Danby under this warranty shall be void.
Boundaries of
If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be
In Home Service
delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for
warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he
responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due
to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its
authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees
under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages
to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of
the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions
(extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application).
Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our
AUTHORIZED SERVICE DEPOT.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
04/09
1-800-263-2629
Warranty Service
In-home
During the first twenty-four (24) months, any functional parts of this product found to be defective,
will be replaced, at warrantor’s option, at no charge to the ORIGINAL purchaser.
First 24 months
LIMITED APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the
unit is used under the normal operating conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada)
or Danby Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or
other contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, by Danby, there are no other warranties, conditions, representations or guarantees, express
or implied, made or intended by Danby or its authorized distributors and all other warranties, conditions, representa-
tions or guarantees, including any warranties, conditions, representations or guarantees under any Sale of Goods Act
or like legislation or statute is hereby expressly excluded. Save as herein provided, Danby shall not be responsible for
any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising
from the malfunction of the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and
hold harmless Danby from any claim for damages to persons or property caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the
following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal
operating conditions (extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not
approved for outdoor application).
Proof of purchase date will be required for warranty claims; please retain bills of sale.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
1-800-263-2629
12/19
31
PRÉCAUTIONS DE SÉCURITÉ
Une mauvaise installation liée à l’omission
d’instructions peut entraîner de graves
dommages ou blessures.
Lorsque vous raccordez la tuyauterie de
réfrigérant, ne laissez pas de substances ou de
gaz autres que le réfrigérant spécifi é pénétrer
l’unité. La présence d’autres gaz ou substances
réduira la capacité de l’unité et pourra entraîner
une pression anormalement élevée au cours du
cycle de réfrigération. Cela peut provoquer une
explosion et vous blesser.
L’installation doit être effectuée par un distributeur
ou spécialiste agréé. Une installation défectueuse
peut entraîner des fuites d’eau, des décharges
électriques ou un incendie.
En Amérique du Nord, l’installation doit être
effectuée conformément aux exigences de la
NEC et de la CEC uniquement par le personnel
autorisé.
Contactez un technicien d’entretien agréé
pour réparer ou effectuer des opérations de
maintenance sur cette appareil.
N’utilisez que les pièces, pièces spécifi ées et
accessoires inclus pour l’installation. L’utilisation
de pièces non standard peut entraîner des fuites
d’eau, des décharges électriques, un incendie et
une défaillance de l’unité.
Installez l’unité à un emplacement stable et
solide, capable de supporter son poids. Si
l’endroit choisi ne peut pas supporter le poids de
l’unité, ou si l’installation n’est pas correctement
effectuée, il est possible que l’unité tombe, ce
qui pourrait entraîner de graves blessures et
dommages.
Pour tous les travaux électriques, respectez
toutes les normes et réglementations locales et
nationales concernant le câblage, ainsi que le
manuel d’installation. Pour l’alimentation, vous
devez utiliser un circuit indépendant et une seule
prise. Ne branchez pas d’autres appareils sur
cette prise. Les capacités électriques insuffi santes
ou les défauts des travaux électriques peuvent
entraîner des décharges électriques ou incendies.
Utilisez les câbles spécifi és pour tous les travaux
électriques. Raccordez et serrez fermement les
câbles pour éviter que des forces extérieures
n’endommagent la borne. Les mauvais
raccordements électriques peuvent entraîner
une surchauffe et un incendie, mais aussi des
décharges électriques.
Tout le câblage doit être organisé de manière
appropriée pour garantir que le couvercle
du tableau de contrôle puisse se refermer
correctement. Si le couvercle du tableau de
contrôle n’est pas correctement refermé, cela
peut favoriser la corrosion, qui à son tour pourrait
chauffer les points de raccordement de la
borne, déclencher un incendie ou entraîner des
décharges électriques.
In certain functional environments, such as
kitchens, server rooms, etc., the use of specially
designed air conditioning units is highly
recommended.
Cet appareil n’est pas destiné à être utilisé par
des personnes (y compris des enfants) dont les
capacités physiques, sensorielles ou métalliques
peuvent être différentes ou réduites, ou qui ont de
l’expérience ou des connaissances, à moins que
ces personnes ne reçoivent de supervision ou de
formation pour faire fonctionner l’appareil par
une personne responsable de leur sécurité.
N’installez pas l’unité dans un lieu susceptible
d’être exposé à des fuites de gaz combustible. Si
du gaz combustible s’accumule autour de l’unité,
cela peut déclencher un incendie.
N’utilisez pas cet appareil dans une pièce
humide, comme une salle de bain ou une
buanderie. Une trop grande exposition à l’eau
peut provoquer un court-circuit des composants
électriques.
L’appareil doit être correctement mis à la terre ou
des chocs électriques peuvent survenir.
Installez la tuyauterie de drainage conformément
aux instructions de ce manuel. Un mauvais
drainage peut causer des dégâts d’eau.
REMARQUE CONCERNANT LES GAZ
FLUORÉS
Ce climatiseur est un appareil hermétiquement
scellé et contient des gaz fl uorés. Pour obtenir
des informations spécifi ques sur le type et
la quantité de gaz, veuillez vous reporter à
l’étiquette concernée apposée sur l’appareil en
elle-même.
L’installation, le service, l’entretien et la réparation
de cet appareil doivent être effectués par un
technicien qualifi é.
La désinstallation et le recyclage de l’appareil
doivent être effectués par un technicien qualifi é.
Si l’appareil dispose d’un système de détection
des fuites, l’absence de fuites doit être vérifi ée au
moins tous les 12 mois. Lors de la vérifi cation des
fuites, un relevé approprié de tous les contrôles
est fortement recommandé.
Consignes de sécurité importantes
LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ
GARDER CES INSTRUCTIONS!
32
ACCESSOIRES
Le système de climatisation comprend les accessoires suivants. Utilisez toutes les pièces d’installation et les
accessoires pour installer le climatiseur. Une mauvaise installation peut provoquer des fuites d’eau, des chocs
électriques, des incendies ou provoquer l’échec de l’équipement.
Dénomination Description Quantité
Plaque de montage 2
Vis de fi xation de la plaque
de montage ST3.9 X 25
10
Agrafe d’ancrage 10
Télécommande 2
Batterie sèche AAA.LR03 4
Joint d’étanchéité 2
Raccord d’évacuation
2
INSTRUCTIONS D’INSTALLATION
33
RÉSUMÉ DE L’INSTALLATION
Remarque: Les illustrations de ce manuel ne sont fournies qu’à des fi ns explicatives. Il est possible que la
forme de votre unité intérieure soit légèrement différente. La véritable forme de l’unité doit prévaloir.
Plaque de montage mural
Panneau avant
Aérateur
Câble d’alimentation
Conduite de drainage
Câble de signal
Conduite de réfrigérant
Télécommande
Câble d’alimentation de
l’appareil extérieure
Filtre fonctionnel
à l’avant du fi ltre principal
INSTRUCTIONS D’INSTALLATION
Remarque: Le modèle DAS180DBAHWDB peut être connecté à plusieurs unités intérieures. Voir la page
suivante pour plus de détails.
34
RÉSUMÉ DE L’INSTALLATION
Lors de l’installation de plusieurs unités intérieures sur une seule unité extérieure, assurez-vous que la longueur
du tuyau de réfrigérant et la hauteur de chute entre les unités intérieure et extérieure répondent aux exigences
suivantes:
49ft (15m)
49ft (15m)
32.8ft (10m)
Unité extérieure
Unité extérieure
Unité extérieure
Unité intérieure
Unités intérieures pouvant être utilisées
en combinaison
Nombre d'unités connectées 1 à 5 unités
Fréquence d'arrêt / de démarrage du
compresseur
Temps d'arrêt 3 minutes ou plus
Tension de la source d'alimentation
Fluctuation de tension à ± 10% de la tension nominale
Chute de tension au
démarrage
à ± 15% de la tension nominale
Déséquilibre d'intervalle à ± 3% de la tension nominale
Les unités sont en mètres / pieds 1 unité 2 1 unité 3 1 unité 4 1 unité 5
Max. longueur pour toutes les pièces 40/131 60/197 80/262 80/262
Max. longueur pour une unité intérieure 25/82 30/98 35/115 35/115
Max. différence de hauteur entre intérieur et extérieur 15/49 15/49 15/49 15/49
Max. différence de hauteur entre les unités intérieures 10/33 10/33 10/33 10/33
INSTRUCTIONS D’INSTALLATION
35
RÉSUMÉ DE L’INSTALLATION - UNITÉ INTÉRIEURE
INSTRUCTIONS D’INSTALLATION
36
RÉSUMÉ DE L’INSTALLATION - UNITÉ INTÉRIEURE
INSTRUCTIONS D’INSTALLATION
37
INSTALLATION DE L’APPREIL INTÉRIEURE
Avant d’installer l’appareil intérieure, reportez-vous à l’étiquette fi gurant sur la boîte du produit pour vous
assurer que le numéro de modèle de l’appareil intérieure correspond à celui de l’appareil extérieure. Le
numéro de modèle de l’appareil intérieur se terminera par un “-I” et le numéro de modèle de l’appareil
extérieur se terminera par un “-O”, sinon ils devraient être identiques.
Étape 1 : choix du lieu d’installation
Voici les normes qui vous aideront à choisir le lieu approprié à l’appareil.
Bonne circulation d’air.
• Évacuation pratique.
Le bruit de l’unité ne dérangera pas d’autres personnes.
Stable et solide; l’emplacement d’installation ne vibrera pas.
Solidité suffi sante pour supporter le poids de l’appareil.
À au moins 1 m (3 pieds) de tous les autres appareils électriques, comme les téléviseurs, les radios et les
ordinateurs, qui pourraient avoir un impact sur le signal à distance infrarouge.
N’installez PAS l’appareil dans les lieux suivants:
À proximité d’une source de chaleur, de vapeur ou de gaz combustible.
À proximité d’éléments infl ammables, par exemple, des rideaux ou du linge.
À proximité d’un obstacle susceptible de bloquer la circulation d’air.
À proximité d’une porte d’entrée.
Dans un lieu directement exposé à la lumière du soleil.
Reportez-vous au schéma suivant pour vous assurer que la distance séparant l’appareil des murs et du
plafond est appropriée:
INSTRUCTIONS D’INSTALLATION
38
Étape 2 : installation de la plaque de fi xation sur le mur
La plaque de fi xation est la pièce sur laquelle vous installerez l’appareil intérieure.
1. Retirez la vis fi xant la plaque de fi xation à l’arrière de l’appareil intérieure.
2. Placez la plaque de montage contre le mur dans l’endroit où l’appareil intérieur sera installé.
3. Percez les trous pour les vis de montage, en veillant à ce que les vis pénètrent dans les goujons de mur
qui peuvent supporter le poids de l’appareil.
4. Vissez la plaque de fi xation au mur avec les vis fournies. Assurez-vous que la plaque de fi xation est bien
à plat contre le mur.
Remarque: Si le mur est en brique, en béton ou autre matériau similaire, percez des trous de 5 mm de
diamètre (0,2 pouce) dans le mur et insérez-y les douilles d’ancrage fournies. Fixez ensuite la plaque au
mur en serrant les vis directement sur les douilles.
Dimensions de la plaque de fi xation
Différentes plaques de fi xation correspondent aux différents
modèles. Pour vous assurer que vous disposez de
suffi samment d’espace pour installer l’unité intérieure, vérifi ez
les diagrammes ci-dessous qui montrent les deux types de
plaques de montage ainsi que les dimensions suivantes:
Largeur de plaque de fi xation.
Hauteur de plaque de fi xation.
Largeur de l’appareil intérieure par rapport à la plaque.
Hauteur de l’appareil intérieure par rapport à la plaque.
Emplacement recommandé pour le trou dans le mur, que
ce soit du côté gauche ou droit de la plaque de fi xation.
Distances relatives entre les trous de vis.
INSTRUCTIONS D’INSTALLATION
10.1 cm (4”)
17.9 cm (7.05”)
13.6 cm (5.35”)
3.7 cm (1.45”)
29 cm (11.4”)
4.9 cm (1.95”)
Trou de paroi
arrière droite
6.5 cm (2.5”)
Contour de l'unité
intérieure
72.2 cm (28.45”)
4.9 cm (1.95”)
22.8 cm (8.98”)
22.9 cm (9.01”)
40.1 cm (15.78”)
12.6 cm (4.96”)
4.2 cm (1.65”)
29.7 cm (11.7”)
80.2 cm (31.6”)
5.8 cm (2.28”)
4.7 cm (1.85”)
Modèle B
Modèle A
34.8 cm (13.7”)
Trou de paroi
arrière gauche
6.5 cm (2.5”)
Trou de paroi
arrière gauche
6.5 cm (2.5”)
Trou de paroi
arrière droite
6.5 cm (2.5”)
Contour de l'unité
intérieure
39
Étape 3 : perçage d’un trou dans le mur pour la tuyauterie de raccordement
Vous devez percer un trou dans le mur pour la tuyauterie de réfrigérant, la conduite d’évacuation, et le câble
de signal qui raccorderont l’appareil intérieure et l’appareil extérieure.
1. Déterminez l’emplacement du trou dans le mur en fonction de l’emplacement de la plaque de fi xation.
Voir l’étape 2 pour le montage des dimensions de la plaque.
2. À l’aide d’un foret aléseur de 65 mm (2,5 pouces), percez un trou dans le mur. Assurez-vous de percer
le trou en respectant un angle légèrement descendant, de manière à ce que l’extrémité extérieure du
tuyau se.
3. Placez le manchon de protection dans le trou. Ce dernier protège les bords du trou et contribuera à
l’étanchéité une fois que vous aurez terminé le processus d’installation.
Remarque: Pendant le perçage du trou dans le mur, veillez à éviter les fi ls, la plomberie et tout autre élément
sensible.
INSTRUCTIONS D’INSTALLATION
40
Étape 4 : préparation de la tuyauterie de réfrigérant
La tuyauterie se situe dans une gaine isolante fi xée à l’arrière de l’unité. Vous
devez préparer la tuyauterie avant de la faire passer par le trou du mur. Reportez-
vous à la section Raccordement de la tuyauterie de réfrigérant de ce manuel
pour obtenir des instructions détaillées sur les exigences d’évasement de conduite
et de couple de serrage pour l’évasement, sur la technique à employer, etc.
1. En vous basant sur la position du trou du mur par rapport à la plaque de
xation, choisissez le côté par lequel la tuyauterie sortira de l’unité.
2. Si le trou du mur se trouve derrière l’appareil, laissez le panneau amovible en
place. Si le trou se trouve au niveau de l’un des côtés de l’appareil intérieure,
retirez le panneau amovible de plastique de ce côté de l’appareil. De
cette manière, une fente par laquelle votre tuyauterie pourra sortir de l’unité
apparaîtra. Utilisez une pince à bec effi lé si le panneau de plastique est trop
diffi cile à retirer à la main.
Panneau de montage
3. Utilisez des ciseaux pour découper la longueur de gaine isolante pour faire apparaître environ 15 cm (6
pouces) de tuyauterie de réfrigérant. Cette opération a deux objectifs:
faciliter le processus de raccordement de la tuyauterie de réfrigérant
Faciliter les vérifi cations à la recherche de fuite de gaz et vous permettre de rechercher les bosses
4. Si la tuyauterie de connexion existante est déjà intégrée dans le mur, passez directement à l’étape
5: Connectez le tuyau de vidange. S’il n’y a pas de tuyauterie intégrée, connectez la tuyauterie de
réfrigérant de l’appareil intérieure à la tuyauterie de connexion qui rejoindra les appareils intérieures et
extérieures.
5. En vous basant sur la position du trou du mur par rapport à la plaque de fi xation, déterminez l’angle
nécessaire à votre tuyauterie. Emparez-vous de la tuyauterie de réfrigérant par la base du coude.
6. Coudez la tuyauterie vers le trou en appliquant lentement une pression régulière. Ne bosselez pas et
n’endommagez pas la tuyauterie au cours de ce processus.
Remarque concernent l’angle de la tuyaterie
La tuyauterie de réfrigérant peut sortir de l’appareil intérieure sous quatre angles différents:
• partie gauche
• arrière gauche
• partie droite
• arrière droite
PRÉCAUTION
Soyez extrêmement prudent : ne bosselez pas et n’endommagez
pas la conduite en la coudant vers l’extérieur de l’unité. Toutes les
bosses de la conduite affecteront le fonctionnement de l’appareil.
INSTRUCTIONS D’INSTALLATION
41
Étape 5 : raccordement du tuyau d’évacuation
Par défaut, le tuyau d’évacuation se raccorde au côté gauche de l’appareil, lorsque vous faites faces à
l’arrière de l’appareil). Il peut cependant être raccordé au côté droit.
1. Pour garantir une bonne évacuation, raccordez le tuyau d’évacuation au côté par lequel votre conduite
de réfrigérant sort de l’appareil.
2. Fixez le raccord de tuyau d’évacuation (acheté séparément) à l’extrémité du tuyau d’évacuation.
3. Enroulez fermement un ruban de téfl on autour du point de raccordement pour garantir une bonne
étanchéité et empêcher les fuites.
4. Pour ce qui est de la portion de tuyau d’évacuation qui restera à l’intérieur du bâtiment, enveloppez-la
d’une pousse isolante pour conduites afi n d’empêcher la condensation.
5. Retirez le fi ltre à air et versez une petite quantité d’eau dans l’entonnoir d’évacuation pour vous assurer
que l’eau s’écoule régulièrement hors de l’unité.
Remarque concernent le tuyau d’évacuation
N’entortillez PAS le tuyau d’évacuation.
Ne créez pas de piège à eau.
Ne placez pas l’extrémité du tuyau d’évacuation dans de l’eau ou dans un récipient qui recueillerait
l’eau.
Remarque: Pour éviter les fuites indésirables, vous devez reboucher le trou d’évacuation inutilisé avec le
bouchon de caoutchouc fourni.
Voir ci-dessous des exemples d’installation correcte du tuyau de vidange:
INSTRUCTIONS D’INSTALLATION
42
LISEZ CES RÉGLEMENTATIONS AVANT D’EFFECTUER TOUT TRAVAIL ÉLECTRIQUE
1. Tout le câblage doit être conforme aux codes électriques locaux et nationaux ; il doit en outre être installé
par un électricien habilité.
2. Tous les raccordements électriques doivent être effectués conformément au Schéma de raccordement
électrique fi gurant sur les panneaux de l’unité intérieure et de l’unité extérieure.
3. Si vous rencontrez un grave problème de sécurité avec l’alimentation, arrêtez immédiatement de
travailler. Expliquez votre raisonnement au client, et refusez d’installer l’unité tant que le problème de
sécurité n’est pas correctement résolu.
4. La tension d’alimentation devrait représenter 90 à 100 % de la tension nominale. Une alimentation
insuffi sante peut entraîner des dysfonctionnements, des décharges électriques ou un incendie.
5. Si vous raccordez l’alimentation à un câblage fi xe, installez une protection contre les surtensions et un
interrupteur d’alimentation principal d’une capacité 1,5 fois supérieure à l’intensité maximale de l’unité.
6. Si vous raccordez l’alimentation à un câblage fi xe, un interrupteur ou un disjoncteur déconnectant tous
les pôles doit être intégré au câblage fi xe. Ce dispositif doit être séparé des contacts d’au moins 3 mm
(1/8 pouce). Le technicien qualifi é doit utiliser un interrupteur ou disjoncteur approuvé.
7. Ne raccordez l’unité qu’à une prise du circuit de dérivation individuel. Ne branchez pas d’autres
appareils sur cette prise.
8. Assurez-vous d’avoir correctement relié le climatiseur à la terre.
9. Tous les câbles doivent être fermement raccordés. Les câbles lâches peuvent entraîner une surchauffe de
la borne, ce qui peut à son tour entraîner dysfonctionnement du produit et un éventuel incendie.
10. Ne laissez pas les câbles toucher ou reposer sur la tubulure de réfrigérant, le compresseur ou toute
autre pièce mobile de l’unité.
AVERTISSEMENT
AVANT D’EFFECTUER TOUTE INTERVENTION ÉLECTRIQUE OU DE
CÂBLAGE, COUPEZ L’ALIMENTATION PRINCIPALE DU SYSTÈME.
AVERTISSEMENT
Tout le câblage doit être effectué conformément au schéma de
câblage situé à l’intérieur du couvercle du fi l de l’appareil intérieur.
Ne mélangez pas les fi ls en direct et nuls. Ceci est dangereux et peut
provoquer un dysfonctionnement de l’appareil.
INSTRUCTIONS D’INSTALLATION
Connectez le câblage aux bornes comme indiqué avec leurs numéros correspondants respectifs sur le
bornier des unités intérieure et extérieure. Par exemple, consultez les modèles Américains suivants: La borne
L1 (A) de l’unité extérieure doit être connectée à la borne L1 de l’unité intérieure.
Faites passer le cordon d’alimentation principal dans la prise de ligne inférieure du serre-câble.
Un-
d
eux mo
d
è
l
es:
Modèle A
Modèle E Modèle F Modèle G
Modèle B Modèle C Modèle D
INSTRUCTIONS D’INSTALLATION
43
44
Étape 6 : connexion du câble de signal
Le câble de signal permet la communication entre l’appareil intérieure et l’unité extérieure. Vous devez
d’abord choisir la taille de câble appropriée avant de le préparer pour le raccordement.
Types de câble:
Câble d’alimentation intérieur (le cas échéant) : H05VV-F or H05V2V2-F
Câble d’alimentation extérieur : H07RN-F
Câble de signal : H07RN-F
Superfi cie minimale de section entre le
câble d’alimentation et le câble de signal
Intensité nominale de l’appareil (A) AWG
10 18
13 16
18 14
25 12
30 10
CHOIX DE LA BONNE TAILLE DE CÂBLE
La taille nécessaire pour le câble d’alimentation, le câble
de signal, le fusible et l’interrupteur se détermine en fonction
de l’intensité maximale de l’unité. L’intensité maximale est
indiquée sur la plaque d’identifi cation située sur le panneau
latéral de l’unité. Reportez-vous à cette plaque pour choisir
le bon câble, le bon fusible ou le bon interrupteur.
Noter les caractéristiques du fusible
Le circuit imprimé du climatiseur (PCB) est muni d’un fusible offrant une protection contre les surintensités. Les
caractéristiques de ce fusible sont imprimées sur le circuit, par exemple: T3.15A/250VAC, T5A/250VAC, etc.
1. Préparation du câble pour le raccordement:
a. À l’aide d’un outil à dénuder, retirez la garniture de caoutchouc des deux extrémités du câble de
signal pour faire apparaître environ 15 cm (6 pouces) des fi ls qu’elle renferme.
b. Dénudez l’isolation des extrémités des fi ls.
c. À l’aide d’une pince à sertir, sertissez des cosses en U aux extrémités des fi ls.
2. Ouvrez le panneau avant de l’unité intérieure.
3. À l’aide d’un tournevis, ouvrez le couvercle du boîtier de câblage situé du côté droit de l’unité. Vous ferez
ainsi apparaître le bornier.
4. Dévissez le serre-câble qui se trouve sous le bornier et placez-le sur le côté.
5. En faisant face à l’arrière de l’unité, retirez le panneau de plastique qui se situe en bas à gauche.
6. Faites passer le câble de signal par cette fente, de l’arrière de l’unité jusqu’à l’avant.
7. En faisant face à l’avant de l’unité, associez les fi ls en vous fi ant aux étiquettes du bornier, connectez la
cosse en U, puis vissez chacun des fi ls sur la borne qui lui correspond.
8. Après avoir vérifi é que tous les raccordements sont bien en place, utilisez le serre-câble pour fi xer le câble
de signal à l’unité. Vissez fermement le serre-câble.
9. Remettez le cache-fi ls en place à l’avant de l’unité et le panneau de plastique à l’arrière.
Schéma de câblage qui
se trouve dans le boîtier
de câblage de l’appareil
intérieure.
Remarque: Lorsque vous
sertissez les fi ls, assurez-
vous de bien distinguer le
l sous tension (« L ») des
autres fi ls.
INSTRUCTIONS D’INSTALLATION
45
Étape 7: enveloppement de la tuyauterie et du câble
Avant de faire passer la tuyauterie de réfrigérant, le tuyau d’évacuation et le câble de signal par le trou du
mur, vous devez les réunir pour gagner de la place, les protéger et les isoler.
1. Réunissez le tuyau d’évacuation, les conduites de réfrigérant et le câble de signal.
Remarque: Assurez-vous que le tuyau d’évacuation se trouve tout en dessous du lot constitué. Placer le tuyau
d’évacuation sur le dessus de ce lot pourrait entraîner un débordement de l’entonnoir d’évacuation, qui à
son tour entraînerait un incendie ou des dégâts des eaux.
2. À l’aide d’un ruban de vinyle adhésif, fi xez le tuyau au dessous des conduites de réfrigérant.
3. À l’aide d’un ruban isolant, enveloppez fermement ensemble le câble de signal, les conduites de
réfrigérant et le tuyau d’évacuation.
Remarque: Lorsque vous réunissez ces éléments ensemble, ne les entremêlez pas et n’entrecroisez pas le
câble de signal avec d’autres câbles.
Remarque: Lorsque vous enveloppez le lot constitué, n’enveloppez pas les extrémités de la tuyauterie. Vous
devez pouvez y accéder pour vérifi er qu’il n’y a pas de fuites à la fi n du processus d’installation.
INSTRUCTIONS D’INSTALLATION
46
Étape 8 : mise en place de l’unité intérieure
Si vous avez installé une nouvelle tuyauterie de raccordement à l’unité extérieure, procédez comme suit:
1. Si vous aviez déjà fait passer une conduite de réfrigérant par le trou du mur, passez à l’étape 4.
2. Sinon, revérifi ez que les extrémités des conduites de réfrigérant sont scellées pour éviter que de la saleté
ou des matériaux étrangers ne pénètrent les conduites.
3. Faites doucement passer le lot enveloppé constitué des conduites de réfrigérant, du tuyau d’évacuation et
du câble de signal par le trou du mur.
4. Accrochez le haut de l’appareil intérieure au crochet supérieur de la plaque de fi xation.
5. Vérifi ez que l’appareil est fermement accrochée à la plaque de fi xation en appliquant une légère
pression sur les côtés gauche et droit de l’appareil. L’appareil ne devrait pas remuer ou se déplacer.
6. En appliquant une pression régulière vers le bas, appuyez sur la moitié inférieure de l’appareil.
Continuez à appuyer jusqu’à ce que l’appareil s’insère sur les crochets qui se situent le long du bas de
la plaque de fi xation.
7. Vérifi ez à nouveau que l’appareil est fermement fi xée en appliquant une légère pression sur les côtés
gauche et droit de l’appareil.
Si la tuyauterie de réfrigérant est déjà intégrée au mur, procédez comme suit:
1. Accrochez le haut de l’appareil intérieure au crochet supérieur de la plaque de fi xation.
2. Utilisez un support ou une cale pour caler l’appareil, en vous conservant suf samment d’espace pour
raccorder la tuyauterie de réfrigérant, le câble de signal et le tuyau d’évacuation.
3. Raccordez le tuyau d’évacuation et la tuyauterie de réfrigérant. Reportez-vous à la section Raccordement
de la tuyauterie de réfrigérant de ce manuel pour obtenir des instructions.
4. Laissez le point de raccordement de la tuyauterie exposer pour pouvoir procéder au test anti-fuites.
Reportez-vous à la section Vérifi cations électriques et recherches de fuites de ce manuel.
5. Une fois le test anti-fuites effectué, enveloppez le point de raccordement d’un ruban isolant.
6. Retirez le support ou la cale qui calait l’appareil.
7. En appliquant une pression régulière vers le bas, appuyez sur la moitié inférieure de l’unité. Continuez
à appuyer jusqu’à ce que l’unité s’insère sur les crochets qui se situent le long du bas de la plaque de
xation.
L’emplacement de l’appareil est ajustable
Les crochets de la plaque de montage sont plus petits que les trous situés à l’arrière de l’appareil. L’appareil
peut être réglé à gauche ou à droite d’environ 30 à 50 mm (1,25 - 1,95 po) selon le modèle.
INSTRUCTIONS D’INSTALLATION
47
INSTALLATION DE L’APPAREIL EXTÉRIEURE
Étape 1 : choix du lieu d’installation
Avant d’installer l’unité extérieure, vous devez choisir un lieu approprié. Les lieux d’installation appropriés
respectent les normes suivantes:
Ils offrent une circulation d’air adéquate et une bonne ventilation.
Ils sont stables et solides : le lieu d’installation peut supporter le poids de l’unité et ne vibrera pa.
Le bruit de l’appareil ne dérangera pas.
Ces lieux sont protégés contre les longues périodes d’exposition directe au soleil ou aux précipitations.
L’emplacement doit répondre aux exigences spatiales décrites ci-dessous:
N’installez pas l’appareil aux endroits suivants:
à proximité d’un obstacle qui obstruera les entrées et sorties d’air.
à proximité d’une rue publique, de zones bondées ou de zones où le bruit de l’appareil dérangera
d’autres personnes.
à proximité d’animaux ou de végétaux pour lesquels l’évacuation d’air chaud serait néfaste.
à proximité d’une source de gaz combustible.
dans un lieu exposé à une grande quantité de poussière.
dans un lieu exposé à une quantité excessive d’air salin.
Considérations particulières concernant les conditions climatiques extrêmes
Si l’appareil est exposé à un vent fort, installez l’appareil afi n que le ventilateur de sortie d’air soit à un
angle de 90 ° par rapport à la direction du vent. Si nécessaire, construisez une barrière devant l’appareil
pour la protéger contre le vent.
Si l’appareil est exposé à de fortes pluies ou à de la neige, construisez un abri au-dessus de l’appareil pour
le protéger. Veillez à ne pas obstruer le fl ux d’air autour de l’appareil.
Si l’appareil est exposé à de l’air salé, utilisez un appareil extérieur spécialement conçu pour résister à la
corosion.
INSTRUCTIONS D’INSTALLATION
48
Étape 2 : installation du raccord d’évacuation
Avant de boulonner l’appareil extérieure en place, vous devez installer le raccord d’évacuation en dessous
de l’appareil.
1. Installez le joint d’étanchéité en caoutchouc sur l’extrémité de raccord d’évacuation qui sera reliée à
l’appareil extérieure.
2. Insérez le raccord d’évacuation dans le trou de l’entonnoir de la base de l’appareil.
3. Faites pivoter le raccord d’évacuation à 90° jusqu’à ce qu’il s’encliquette en place, face à l’avant de
l’appareil.
4. Installez un raccord de tuyau d’évacuation (non fourni) sur le raccord d’évacuation que vous venez
d’encliqueter sur l’unité pour rediriger l’eau provenant de l’unité en mode chauffage.
Le trou de base pour le joint de drain se trouve au bas de l’appareil.
En cas de climats froids
En cas de climats froids, assurez-vous que le raccord d’évacuation est aussi vertical que possible, ce qui
garantira la rapidité d’évacuation de l’eau. Si l’eau est évacuée trop lentement, elle peut geler dans le tuyau
et submerger l’appareil.
INSTRUCTIONS D’INSTALLATION
49
Étape 3 : ancrage de l’appareil extérieure
L’appareil extérieure peut être ancrée au sol ou installée sur un support fi xé au mur.
Voici une liste des tailles d’appareils extérieurs et la distance entre leurs pieds de montage. Préparez la base
d’installation de l’appareil en fonction des dimensions et des images ci-dessous.
Si vous prévoyez d’installer l’unité au sol ou sur une plateforme d’installation en béton, procédez
comme suit:
1. Marquez les positions des quatre boulons expanseurs selon les dimensions du tableau dimensions
d’installation d’appareil.
2. Prépercez des trous pour les boulons expanseurs.
3. Éliminez la poussière de béton des trous.
4. Placez un écrou à l’extrémité de chaque boulon expanseur.
5. Martelez les boulons expanseurs sur les trous prépercés.
6. Retirez les écrous des boulons expanseurs, puis placez l’unité extérieure sur les boulons.
7. Placez une rondelle sur chaque boulon expanseur, puis remettez les écrous en place.
8. À l’aide d’une clé, serrez chaque écrou jusqu’à ce qu’il le soit suffi samment.
AVERTISSEMENT
Lors du forage dans le béton,
la protection des yeux doit
être portée en tout temps.
Si vous prévoyez d’installer l’unité sur un support fi xé au mur, procédez comme suit:
1. Marquez les positions des trous du support en vous basant sur les dimensions du tableau dimensions
d’installation d’appareil.
2. Prépercez des trous pour les boulons expanseurs.
3. Éliminez la poussière et les débris des trous.
4. Placez une rondelle et un écrou à l’extrémité de chaque boulon expanseur.
5. Faites passer les boulons expanseurs par les trous des supports de fi xation, mettez les supports de fi xation
en place puis martelez les boulons expanseurs sur le mur.
6. Vérifi ez que les supports de fi xation sont à niveau.
7. Soulevez délicatement l’appareil et placez ses pieds de fi xation sur les supports.
8. Boulonnez fermement l’appareil sur les supports.
Remarque: Pour réduire les vibrations et le bruit d’un appareil monté sur un mur, installez l’appareil avec des
joints en caoutchouc.
Tableau des dimensions de montage de l’appareil
Numéro de modèle Dimensions d’appareil (L x H x P)
Distance A
(mm / po)
Distance B
(mm / po)
DAS180DBAHWDB 922x715x379 (36.3”x28.2”x14.9”) 540 (21.26”) 350 (13.8”)
INSTRUCTIONS D’INSTALLATION
50
Étape 4 : Connexion du câble de signal et du câble d’alimentation
Le bornier de l’appareil extérieure est protégé par un cache-fi ls électriques. qui se trouve sur le côté de
l’appareil. Un schéma de câblage complet est imprimé à l’intérieur du cache-fi ls.
Types de câble:
Câble d’alimentation intérieur (le cas échéant) : H05VV-F ou H05V2V2-F
Câble d’alimentation extérieur : H07RN-F
Câble de signal : H07RN-F
1. Préparez le câble pour le raccordement:
a. À l’aide d’un outil à dénuder, retirez la garniture de caoutchouc des deux extrémités du câble de
signal pour faire apparaître environ 40 mm (1.57 pouces) des fi ls qu’elle renferme.
b. Dénudez l’isolation des extrémités des fi ls.
c. À l’aide d’une pince à sertir, sertissez des cosses en U aux extrémités des fi ls.
2. Dévissez le cache-fi ls électriques et retirez-le.
3. Dévissez le serre-câble qui se trouve sous le bornier et placez-le sur le côté.
4. Associez les couleurs/étiquettes des fi ls en vous basant sur les étiquettes du bornier, puis vissez
fermement la cosse en U de chaque fi l sur la borne qui lui correspond.
5. Après avoir vérifi é que tous les raccordements sont bien en place, formez une boucle avec les fi ls pour
éviter que l’eau de pluie ne submerge les bornes.
6. À l’aide du serre-câble, fi xez le câble sur l’unité. Vissez fermement le serre-câble.
7. Isolez les fi ls inutilisés avec du ruban électrique PVC. Organisez ces fi ls de manière à ce qu’ils ne
touchent pas les pièces électriques ou métalliques
8. Remettez le cache-fi ls en place sur le côté de l’unité, puis vissez-le.
Superfi cie minimale de section
entre le câble d’alimentation
et le câble de signal
Intensité nominale de
l’appareil (A)
AWG
10 18
13 16
18 14
25 12
30 10
Schéma de câblage
d’appareil extérieure qui
se situe dans le cache-fi ls
de cette appareil.
AVERTISSEMENT
Tout le câblage doit être effectué conformément au schéma de
câblage situé à l’intérieur du couvercle du fi l de l’appareil intérieur.
Ne mélangez pas les fi ls en direct et nuls. Ceci est dangereux et peut
provoquer un dysfonctionnement de l’appareil.
Cache
Remarque: Lorsque vous
sertissez les fi ls, assurez-
vous de bien distinguer le
l sous tension (« L ») des
autres fi ls.
INSTRUCTIONS D’INSTALLATION
51
RACCORDEMENT DE LA TUYAUTERIE DE RÉFRIGÉRANT
La longueur de la tuyauterie de réfrigérant affectera les performances et l’ef cacité énergétique de l’appareil.
L’effi cacité nominale est testée sur des unités dont la longueur de conduite est de 5 mètres (16,5 pieds).
INSTRUCTIONS DE RACCORDEMENT – TUYAUTERIE DE RÉFRIGÉRANT
Étape 1 : découpe des conduites
Lorsque vous préparez les conduites de réfrigérant, redoublez de prudence pour les découper et les
évaser correctement. Cela garantira l’effi cacité du fonctionnement et minimisera le besoin de maintenance
ultérieure.
1. Mesurez la distance séparant l’unité intérieure de l’unité extérieure.
2. À l’aide d’un coupe-tube, découpez une longueur de conduite légèrement plus importante que la
distance mesurée.
3. Veillez à découper la conduite en respectant un angle parfait de 90°.
Remarque: Ne pas endommager,
bosse ou déformer le tuyau
pendant la coupe. Cela réduira
considérablement l’effi cacité de
chauffage de l’unité.
Étape 2 : élimination des ébarbures
Les ébarbures peuvent affecter l’étanchéité
du joint de raccordement de la tuyauterie
de réfrigérant. Elles doivent être totalement
éliminées.
1. Maintenez le tuyau incliné vers le bas
pour éviter que les bavures ne pénètrent
à l’intérieur du tube.
2. À l’aide d’un alésoir ou d’un ébavureur,
retirez les bavures de la section du tuyau
coupé.
INSTRUCTIONS D’INSTALLATION
52
Étape 3 : évasement des extrémités de conduite
Il est essentiel d’évaser correctement la conduite pour obtenir une étanchéité hermétique.
1. Après avoir ébarbé les rebords du tuyau coupé, scellez ces extrémités avec du ruban PVC pour
empêcher tout corps étranger de pénétrer à l’intérieur du tube.
2. Gainez le tube avec un matériau isolant.
3. Placez des écrous évasés aux deux extrémités de la conduite. Assurez-vous qu’ils sont orientés dans la
bonne direction. Vous ne pourrez plus en remettre ou changer leur direction après l’évasement.
4. Retirez le ruban PVC des deux extrémités de la conduite une fois que vous êtes prêt à procéder à
l’évasement.
5. Fixez le gabarit d’évasement à l’extrémité du tuyau. L’extrémité de la conduite doit s’étendre au-delà du
bord de la forme d’évasement, en respectant les dimensions indiquées dans le tableau ci-dessous.
6. Placez l’outil à évaser dans la forme.
7. Tournez le manche de l’outil à évaser dans le sens horaire jusqu’à ce que la conduite soit entièrement
évasée.
8. Retirez l’outil à évaser et la forme d’évasement, puis inspectez l’extrémité de la conduite à la recherche
de fi ssures et pour vérifi er si l’évasement est régulier.
EXTENSION DE LA TUYAUTERIE AU-DELÀ DE LA FORME D’ÉVASEMENT
Diamètre externe de la conduite (mm) Dimension A Minimum (mm) Dimension A Maximum (mm)
Ø 6.35 (Ø 0.25 po) 0.7 (0.0275 po) 1.3 (0.05 po)
Ø 9.52 (Ø 0.375 po) 1.0 (0.04 po) 1.6 (0.063 po)
Ø 12.7 (Ø 0.5 po) 1.0 (0.04 po) 1.8 (0.07 po)
Ø 16 (Ø 0.63 po) 2.0 (0.078 po) 2.2 (0.086 po)
INSTRUCTIONS D’INSTALLATION
53
Étape 4 : raccordement des conduites
Lorsque vous raccordez les conduites de réfrigérant, veillez à ne pas employer
un couple excessif et à ne pas déformer la tuyauterie de quelque manière que
ce soit. Vous devez d’abord raccorder la conduite basse pression, puis la
conduite haute pression.
Remarque: Lorsque vous coudez la tuyauterie de raccordement pour réfrigérant,
le rayon minimal du coude est de 10 cm.
INSTRUCTIONS DE RACCORDEMENT DE LA TUYAUTERIE À L’APPAREIL INTÉRIEURE
1. Alignez le centre des deux conduites que vous allez raccorder.
2. Serrez l’écrou évasé aussi fermement que possible à la main.
3. À l’aide d’une tricoise, serrez l’écrou sur la tubulure de l’unité.
4. Tout en serrant fermement l’écrou et la tubulure de l’unité, utilisez une clé dynamométrique pour serrer
l’écrou évasé en respectant les valeurs de couple du tableau Exigences de couple qui fi gure ci-dessous.
Desserrez légèrement l’écrou évasé, puis resserrez-le.
EXIGENCES DE COUPLE
Diamètre externe de la
conduite (mm)
Couple de serrage (N•cm) Couple de serrage
supplémentaire (N•m)
Ø 6.35 (Ø 0.25 po) 1,500 (11 livres•pied) 1,600 (11.8 livres•pied)
Ø 9.52 (Ø 0.375 po) 2,500 (18.4 livres•pied) 2,600 (19.18 livres•pied)
Ø 12.7 (Ø 0.5 po) 3,500 (25.8 livres•pied) 3,600 (26.55 livres•pied)
Ø 16 (Ø 0.63 po) 4,500 (19 livres•pied) 4,700 (34.67 livres•pied)
Une force excessive pourrait briser
l’écrou ou endommager la tuyauterie
de réfrigérant. Vous ne devez pas
dépasser les exigences de couple
indiquées dans le tableau ci-dessus.
INSTRUCTIONS D’INSTALLATION
54
INSTRUCTIONS DE RACCORDEMENT DE LA TUYAUTERIE À L’APPAREIL EXTÉRIEURE
1. Dévissez le couvercle de la vanne à presse-étoupe qui se trouve sur le côté de l’appareil extérieure.
2. Retirez les capuchons de protection des extrémités des vannes.
3. Alignez l’extrémité évasée de chacune des conduites avec chacune des vannes, puis serrez l’écrou
évasé aussi fermement que possible à la main.
4. À l’aide d’une tricoise, serrez le corps de la vanne. Ne serrez pas l’écrou étanchéifi ant la vanne de
service.
5. Tout en serrant fermement le corps de la vanne, utilisez une clé dynamométrique pour serrer l’écrou évasé
en respectant les valeurs de couple appropriées.
6. Desserrez légèrement l’écrou évasé, puis resserrez-le.
7. Répétez les étapes 3 à 6 pour la conduite restante.
INSTRUCTIONS D’INSTALLATION
55
PURGE DE L’AIR
Préparations et précautions
Si de l’air ou un matériau étranger est présent dans le circuit de réfrigérant, cela peut entraîner une pression
anormale dans les conduites, qui à son tour peut endommager le climatiseur, réduire son effi cacité et
occasionner des blessures. Utilisez une pompe à vide et un manomètre pour purger le circuit de réfrigérant.
Vous éliminerez ainsi les gaz non condensables et l’humidité du système.
La purge doit être effectuée dès la première installation et lorsque l’unité est déplacée.
Avant de procéder à la purge:
Effectuez une vérifi cation pour vous assurer que la conduite basse pression et que la conduite haute
pression qui relient l’unité intérieure et l’unité extérieure sont toutes deux correctement.
Effectuez une vérifi cation pour vous assurer que tout le câblage est correctement connecté.
Instructions pour la purge
Avant d’utiliser une pompe à vide et un manomètre, lisez leurs modes d’emploi pour vous familiariser avec la
méthode d’utilisation appropriée.
INSTRUCTIONS D’INSTALLATION
56
Instructions pour la purge
1. Raccordez le tuyau de chargement du manomètre à l’orifi ce de service de la vanne basse pression de
l’unité extérieure.
2. Raccordez un autre tuyau de chargement du manomètre à la pompe à vide.
3. Ouvrez le côté basse pression du manomètre. Laissez le côté haute pression fermé.
4. Allumez la pompe à vide pour purger le système.
5. Faites-la fonctionner pendant au moins 15 minutes, ou jusqu’à ce que le compteur combiné affi che -76
cmHG (-105 kPa).
6. Fermez le côté Basse pression du manomètre, puis éteignez la pompe à vide.
7. Patientez 5 minutes, puis vérifi ez que la pression du système est bien restée inchangée.
8. Si la pression du système a changé, reportezvous à la section Recherche de fuites de gaz pour obtenir
des informations sur la méthode de recherche des fuites. Si la pression du système n’a pas changé,
dévissez le capuchon de la vanne à presse-étoupe (vanne haute pression).
9. Insérez une clé hexagonale dans la vanne à presse-étoupe (vanne haute pression) et ouvrez la vanne en
tournant la clé d’un quart de tour dans le sens antihoraire. Écoutez pour entendre si des gaz sortent du
système, puis refermez la vanne après 5 secondes.
10. Observez le manomètre pendant une minute pour vous assurer que la pression du système n’a
pas changé. Le manomètre devrait affi cher une pression légèrement plus élevée que la pression
atmosphérique.
11. Retirez le tuyau de chargement de l’orifi ce de service.
12. À l’aide d’une clé hexagonale, ouvrez complètement les deux vannes : la vanne basse pression et la
vanne haute pression..
13. Serrez à la main les capuchons de la totalité des trois vannes (la vanne de service, la vanne basse
pression et la vanne haute pression). Si nécessaire, vous pouvez les serrer davantage à l’aide d’une clé
dynamométrique.
AVERTISSEMENT
NE MÉLANGEZ PAS
PLUSIEURS TYPES DE
RÉFRIGÉRANT
INSTRUCTIONS D’INSTALLATION
Réfrigérant supplémentairepar longueur de conduite
Longueur de la
tuyauterie de
raccordement (m)
Méthode
de purge
de l’air
Réfrigérant supplémentaire
< Longueur de
tuyau standard
Pompe à
vide
N/A
> Longueur de
tuyau standard
Pompe à
vide
Côté liquide: Ø 6,35 (ø 0,25 po)
R410a:
(Longueur de tuyau - LS) x 15g/m
(Longueur de tuyau - LS) x 0.16oZ/ft
Côté liquide: Ø 9,52 (ø 0,375 po)
R410a:
(Longueur de tuyau - LS) x 30g/m
(Longueur de tuyau - LS) x 0.32oZ/ft
57
Remarque: La vanne ouverte se dégage doucement. Lorsque vous ouvrez les tiges de la soupape, tournez la
clé hexagonale jusqu’à ce qu’elle frappe le bouchon. N’essayez pas de forcer la vanne à ouvrir davantage.
Remarque: Certains systèmes nécessitent une charge supplémentaire en fonction des longueurs de tuyau. La
longueur standard du tuyau varie selon les réglementations locales. Par exemple, en Amérique du Nord, la
longueur standard de la conduite est de 7,5 m (25 pieds). Dans d’autres domaines, la longueur standard du
tube est de 5 m (16 pieds). Le réfrigérant supplémentaire à charger peut être calculé en utilisant la formule
ci-dessous.
LS = Longueur Standard
INSTRUCTIONS D’INSTALLATION
58
RECHERCHES DE FUITES ÉLECTRIQUES ET DE FUITES DE GAZ
Vérifi cations de sécurité électrique
Après l’installation, vérifi ez que tout le câblage est installé conformément aux réglementations locales et
nationales, ainsi qu’au manuel d’installation.
Vérifi ez la mise à la terre
Évaluez visuellement la résistance de la mise à la terre et mesurez-la avec un testeur de résistance de la mise
à la terre. La résistance de mise à la terre doit être inférieure à 4.
Recherche de fuite électrique
During the test run, use an electroprobe and multimeter to perform a comprehensive electrical leakage test.
Si vous détectez une fuite électrique, éteignez immédiatement l’unité et contactez un électricien habilité
à la détection et à la résolution des fuites électriques.
Recherche des fuites de gaz
Deux méthodes différentes permettent de rechercher les fuites de gaz.
Méthode à l’eau savonneuse
À l’aide d’une brosse douce, appliquez de l’eau savonneuse ou du détergent liquide sur tous les points de
raccordement de l’unité intérieure et de l’unité extérieure. La présence de bulles indique qu’il y a une fuite.
Méthode avec détecteur de fuite
Si vous utilisez un détecteur de fuite, à son mode d’emploi pour obtenir les instructions d’utilisation
appropriées.
Remarque: Après avoir vérifi é qu’il n’y aucune fuite au niveau d’aucun des points de raccordement des
conduites, remettez le couvercle de la vanne de l’unité extérieure en place.
AVERTISSEMENT
TOUT LE CÂBLAGE DOIT ÊTRE CONFORME
AUX CODES ÉLECTRIQUES LOCAUX ET
NATIONAUX ; IL DOIT EN OUTRE ÊTRE
INSTALLÉ PAR UN ÉLECTRICIEN HABILITÉ.
INSTRUCTIONS D’INSTALLATION
EXÉCUTER LE TEST
Avant la série de tests, vérifi ez que le système électrique de l’unité est sécurisé et qu’il fonctionne
correctement. Vérifi ez tous les raccordements à écrou évasé et assurez-vous que le système ne présente
aucune fuite. Vérifi ez que les vannes de gaz et de liquide (haute pression et basse pression) sont
entièrement ouvertes.
Instructions pour la série de tests
1. Branchez l’unité pour qu’elle soit alimentée.
2. Appuyez sur le bouton ON/OFF (Marche/arrêt) de la télécommande pour l’allumer.
3. Appuyez sur le bouton MODE (Mode) pour faire défi ler les fonctions suivantes, une à une:
COOL (REFROIDISSEMENT) : choisissez la température la plus faible possible
HEAT (CHAUFFAGE) : sélectionnez la température la plus élevée possible
4. Laissez chacune des fonctions s’exécuter pendant 5 minutes, puis effectuez les vérifi cations suivantes:
Aucune fuite électrique
L’unité est correctement reliée à la terre
Toutes les bornes électriques sont correctement recouvertes
L’unité intérieure et l’unité extérieure sont solidement installées
Aucun des points de raccordement des conduites ne fuit
L’eau s’écoule correctement du tuyau d’évacuation
Toute la tuyauterie est correctement isolée
La fonction REFROIDISSEMENT de l’unité s’exécute correctement
La fonction CHAUFFAGE de l’unité s’exécute correctement
Les aérateurs à lames de l’unité intérieure tournent correctement
L’unité intérieure réagit à la télécommande
IMPORTANT: La pression du circuit de réfrigération augmentera lors de cette opération. Cette opération peut
permettre de découvrir des fuites qui n’avaient pas été détectées lors de votre recherche initiale de fuite. Au
cours de la série de tests, prenez le temps de revérifi er tous les points de raccordement des conduites de
réfrigérant pour vous assurer qu’ils ne fuient pas.
5. Une fois que vous aurez terminé la série de tests avec succès, utiliser la télécommande, rétablissez
la température de fonctionnement normale de l’appareil. À l’aide d’un ruban isolant, enveloppez les
raccordements de conduites de réfrigérant que vous avez laissés à nu lors du processus d’installation de
l’appareil.
Test exécuté en basse température
Si la température ambiante est inférieure à 17°C (63°F), vous ne pouvez pas utiliser la télécommande pour
activer la fonction REFROIDISSEMENT. Dans un tel cas, vous pouvez utiliser le bouton MANUAL CONTROL
(CONTRÔLE MANUEL) pour tester la fonction REFROIDISSEMENT.
1. Soulevez le panneau avant de l’unité intérieure, puis levez-le jusqu’à ce qu’il s’encliquette en place.
2. Le bouton MANUAL CONTROL (CONTRÔLE MANUEL) se situe du côté droit de l’unité. Appuyez deux
fois dessus pour sélectionner la fonction COOL (REFROIDISSEMENT).
3. Effectuez la série de tests comme habituellement.
Lignes directrices pour l’élimination
Cet appareil contient du réfrigérant et d’autres matériaux potentiellement dangereux. Lorsque vous
mettez cet appareil au rebut, la loi exige que vous preniez des mesures particulières pour la collecte
et le traitement des déchets. Ne mettez pas ce produit au rebut comme s’il s’agissait de déchets
ménagers ou de déchets municipaux non triés.
59
INSTRUCTIONS D’INSTALLATION
LIMITED IN-HOME APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating
conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter
“Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
First Year
During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the ORIGINAL purchaser.
To obtain
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance
Service
requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at
their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below.
Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service
must be performed by a qualied service technician.
If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all
obligations of Danby under this warranty shall be void.
Boundaries of
If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be
In Home Service
delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for
warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he
responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due
to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its
authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees
under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages
to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of
the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions
(extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application).
Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our
AUTHORIZED SERVICE DEPOT.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
04/09
1-800-263-2629
Warranty Service
In-home
Pendant les premiers vingt quatre (24) mois, toutes les pièces fonctionnelles de ce produit qui
s’avèrent défectueuses seront réparées ou remplacées, selon le choix du garant, sans frais à
l’acheteur INITIAL.
Premiers 24 mois
GARANTIE LIMITÉE DE L'APPAREIL
Cet appareil de qualité est garanti exempt de tout vice de matière première et de fabrication, s’il est utilisé dans les
conditions normales recommandées par le fabricant.
Cette garantie n’est offerte qu’à l’acheteur initial de l’appareil vendu par Danby Products Limited (Canada) ou Danby
Products Inc. (E.- U.A.) (ci-après « Danby ») ou par l’un des ses distributeurs agréés et elle ne peut être transférée.
CONDITIONS
Les pièces en plastique sont garanties pendant trente (30) jours seulement à partir de la date de l’achat, sans aucune
prolongation prévue.
Aucune partie de la garantie ne prévoit implicitement que le fabricant sera tenu responsable des dommages subis par
les aliments ou d’autres types de contenu, qu’ils soient causés par la défectuosité de l’appareil ou par son usage
adéquat ou inadéquat.
EXCLUSIONS
En vertu de la présente, il n’existe aucune autre garantie, condition ou représentation, qu’elle soit exprimée ou tacite,
de façon manifeste ou intentionnelle, par Danby ou ses distributeurs agréés. De même, sont exclues toutes les autres
garanties, conditions ou représentations, y compris les garanties, conditions ou représentations en vertu de toute loi
régissant la vente de produits ou de toute autre législation ou règlement semblables. En vertu de la présente, Danby ne
peut être tenue responsable en cas de blessures corporelles ou des dégâts matériels, y compris à l’appareil, quelle
qu’en soit les causes. Danby ne peut pas être tenue responsable des dommages indirects dus au fonctionnement
défectueux de l’appareil. En achetant l’appareil, l’acheteur accepte de mettre à couvert et de dégager Danby de toute
responsabilité en cas de réclamation pour toute blessure corporelle ou tout dégât matériel causé par cet appareil.
CONDITIONS GÉNÉRALES
La garantie ou assurance ci-dessus ne s’applique pas si les dégâts ou réparations sont dus aux cas suivants:
1) Panne de courant.
2) Dommage subis pendant le transport ou le déplacement de l’appareil.
3) Alimentation électrique incorrecte (tension faible, câblage défectueux, fusibles incorrects).
4) Accident, modification, emploi abusif ou incorrect de l’appareil tel qu'une circulation d'air inadéquate dans la pièce
ou des conditions de fonctionnement anormales (température extrêmement élevée ou basse).
5) Utilisation dans un but commercial ou industriel (à savoir, si l'appareil n'est pas installé dans un domicile résidentiel).
6) Incendie, dommages causés par l’eau, vol, guerre, émeute, hostilités, cas de force majeure (ouragan, inondation,
etc.).
7) Visites d’un technicien pour expliquer le fonctionnement de l’appareil au propriétaire.
8) Installation inappropriée (par exemple, encastrement d'un appareil autoportant, ou utilisation extérieure d'un
appareil non conçu à cet effet).
Une preuve d’achat doit être présentée pour toute demande de réparation sous garantie. Prière de garder le reçu.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Téléphone : (519) 837-0920 Télécopieur: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Téléphone: (419) 425-8627 Télécopieur: (419) 425-8629
1-800-263-2629
12/19
61
PRECAUCIONES DE SEGURIDAD
La instalación incorrecta debido a ignorar o hacer
caso omiso a las instrucciones puede causar serios
daños o lesiones.
Al conectar tuberías/líneas del refrigerante, no
deje que sustancias o gases que no sean del
tipo de refrigerante especifi cado entren en las
líneas, ya que esto reducirá la capacidad de la
unidad y puede causar una presión alta anormal
en el sistema de refrigeración, lo que puede
provocar una explosión o lesiones.
La instalación debe ser realizada por un
técnico certifi cado en Aire Acondicionado. La
instalación incorrecta puede causar fugas de
agua, descargas eléctricas o incendio.
En Norte América (EE.UU), la instalación debe
realizarse de acuerdo con los estándares y
normas de NEC y CEC, sólo por personal
autorizado.
Favor de ponerse en contacto con un técnico
especializado en Aire Acondicionado o con
el agente de ventas para obtener información
sobre la reparación o el mantenimiento de este
producto/unidad.
Utilice únicamente los accesorios, piezas y
partes especifi cadas para la instalación. El uso
de partes - no estándar - pudieran ocasionar
fugas de agua, descargas eléctricas, incendios y
puede causar fallos de esta unidad.
Instale este producto/unidad en una ubicación
rme que pueda soportar el peso de la unidad.
Si el lugar elegido no puede soportar el peso
de la unidad , o si la instalación no se ha hecho
correctamente, la unidad puede caerse y causar
graves lesiones o daños.
Para todos los trabajos eléctricos, siga todas las
normas y reglamentos locales /nacionales de
cableado, así como las indicadas en este y este
manual. Debe utilizar un circuito independiente y
un solo enchufe/ toma corriente para suministrar
energía. No conecte otros aparatos en el mismo
toma de corriente. La insufi ciencia de capacidad
eléctrica o los defectos en el trabajo eléctrico
pueden causar descargas eléctricas o incendios.
Para todos los trabajos eléctricos, utilice todos
los cables especifi cados. Conecte los cables
rmemente y sujételos en forma segura para
evitar que las fuerzas externas dañen el terminal.
Las conexiones eléctricas inadecuadas pueden
recalentarse y provocar descargas eléctricas o
incendios.
Todos los cables deben estar correctamente
colocados para asegurar que la tarjeta de
control pueda cerrarse correctamente. Si la
cubierta de la tarjeta de control no está cerrada
correctamente, puede provocar corrosión y
causar que los puntos de conexión del terminal
se sobrecalienten, se incendien o provoquen una
descarga eléctrica.
En algunos ambientes o áreas, como cocinas,
salas de computo etc., se recomienda el uso
de unidades de aire acondicionado diseñadas
especialmente para ese propósit.
Esta unidad no está diseñado para ser usado por
personas (incluyendo niños) cuyas capacidades
físicas, sensoriales o mentales puedieran ser
diferentes o reducidas, o que carezcan de
experiencia o conocimiento, a menos que dichas
personas reciban supervisión o entrenamiento
para operar la unidad por una persona
responsable de su cuidado y seguridad.
No instale la unidad en un lugar que pueda
estar expuesto a fugas de gas combustible. Si
se acumula gas combustible alrededor de la
unidad, podría provocar un incendio.
No utilice esta unidad en un cuarto húmedo,
como un cuarto de baño o cerca de un
lavadero. Demasiada exposición al agua
puede causar cortocircuitos en los componentes
eléctricos.
Esta unidad deberá de estar debidamente
conectado a tierra o puede producirse una
descarga eléctrica.
Instale la tubería de drenaje de acuerdo con
las instrucciones de este manual. Un drenaje
inadecuado puede causar daños por agua.
NOTA SOBRE LOS GASES FLUORADOS
Esta unidad contiene gases fl uorados. Para
obtener mas información específi ca sobre el
tipo y la cantidad de gas, consulte la etiqueta
correspondiente en el propio equipo.
La instalación, servicio, mantenimiento y
reparación de este electrodoméstico deben ser
realizados por un técnico certifi cado en Aire
Acondicionado.
La desinstalación y el reciclaje deben ser
realizados por un técnico certifi cado en Aire
Acondicionado.
Si la unidad esta equipada con un sistema de
detección de fugas, deberá de verifi car que no
haya fugas al menos cada 12 meses. Cuando
se comprueba si hay fugas en la unidad, es
altamente recomendable que se mantengan
registros de todas las verifi caciones.
GARDER CES INSTRUCTIONS!
Informacion de Seguridad Importante
LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD
62
ACCESORIOS
El sistema de aire acondicionado viene con los siguientes accesorios. Utilice todas las piezas de instalación
y accesorios para instalar el acondicionador de aire. Una instalación incorrecta puede ocasionar fugas de
agua, descargas eléctricas, incendio o puede causar que el equipo falle.
Parte Imagen Cantidad
Placa de montaje 2
Tornillo de fi jación de la placa de
montaje ST3.9 x 25
10
Anclajes tipo clip
10
Control remoto 2
Pilas secas AAA.LR03 4
Sello 2
Articulación de drenar
2
INSTRUCCIONES DE INSTALACIÓN
63
RESUMEN DE LA INSTALACIÓN
Nota: Las ilustraciones de este manual son sólo para propósitos explicativos. La forma real del aparato
puede ser ligeramente diferente. La forma real prevalecerá.
Placa de montaje mural
Panel frontal
Persiana
Cable de energía
Tubo de drenaje
Cable de señal
Tubería de refrigerante
Control remoto
Unidad exterior
Cable de energía
Filtro Funcional
En el frente del fi ltro principal
INSTRUCCIONES DE INSTALACIÓN
Nota: El modelo DAS180DBAHWDB se puede conectar a múltiples unidades interiores. Vea la página
siguiente para más detalles.
64
RESUMEN DE LA INSTALACIÓN
Al instalar varias unidades interiores en una sola unidad exterior, asegúrese de que la longitud del tubo de
refrigerante y la altura de caída entre las unidades interior y exterior cumplan los siguientes requisitos:
49ft (15m)
49ft (15m)
32.8ft (10m)
Unidad exterior
Unidad exterior
Unidad exterior
Unidad interior
Unidades interiores que se pueden
usar en combinación
Cantidad de unidades
conectadas
1 - 5 unidades
Frecuencia de parada / arranque del
compresor
Para el tiempo 3 minutos o más
Voltaje de la fuente de alimentación
Fluctuación de voltaje dentro de ±10% del voltaje nominal
Caída de voltaje durante
el inicio
dentro de ±15% del voltaje nominal
Desbalance de intervalo dentro de ±3% del voltaje nominal
Las unidades están en metros / pies 1 unidad 2 1 unidad 3 1 unidad 4 1 unidad 5
Max. longitud para todas las habitaciones 40/131 60/197 80/262 80/262
Max. longitud para una unidad interior 25/82 30/98 35/115 35/115
Max. diferencia de altura entre interior y exterior 15/49 15/49 15/49 15/49
Max. diferencia de altura entre unidades interiores 10/33 10/33 10/33 10/33
INSTRUCCIONES DE INSTALACIÓN
65
RESUMEN DE LA INSTALACIÓN - UNIDAD INTERIOR
INSTRUCCIONES DE INSTALACIÓN
66
RESUMEN DE LA INSTALACIÓN - UNIDAD INTERIOR
INSTRUCCIONES DE INSTALACIÓN
67
INSTALACIÓN DE UNIDAD INTERIOR
Antes de instalar la unidad interior, consulte la etiqueta de la caja del producto para asegurarse de que el
número de modelo de la unidad interior coincida con el número de modelo de la unidad exterior. El número
de modelo de la unidad interior terminará con un “-I” y el número de modelo de la unidad exterior fi nalizará
con un “-O”, de lo contrario deberán ser idénticos.
Paso 1: Seleccione el lugar adecuado para la instalación
Los lugares adecuados de instalación cumplen con los siguientes estándares:
Buena circulación de aire.
• Drenaje adecuado.
El ruido producido por operación de la unidad no molesta a las personas o animales.
Ubicación fi rme y sólida para evitar la vibración
Sufi cientemente fuerte para soportar el peso de la unidad.
Al menos 1 m (3 pies) de distancia de todos los demás dispositivos eléctricos, como televisores, radios y
computadoras, lo que podría afectar a la señal remota de infrarrojos.
No instale la unidad interior en lugares que tengan lo siguientes condiciones:
Cerca de cualquier fuente de calor, vapor o gas combustible.
Cerca de artículos infl amables como cortinas o ropa.
Cerca de cualquier obstáculo que pueda bloquear la circulación del aire.
Cerca de cualquier puerta.
Donde la exposición a luz solar sea directa
Refi érase a la siguiente ilustración para asegurar la distancia apropiada de las paredes circundantes y del
techo:
INSTRUCCIONES DE INSTALACIÓN
68
Paso 2: Fije la placa para montaje a la pared
La placa de montaje es el dispositivo que sujeta la unidad interior a la pared.
1. Quite el tornillo que une la placa de montaje a la parte posterior de la unidad interior.
2. Coloque la placa de montaje contra la pared en el lugar donde se instalará la unidad interior.
3. Perfore agujeros para los tornillos de montaje, asegurándose de que los tornillos entren en los montantes
de pared que pueden soportar el peso de la unidad.
4. Fije la placa de montaje a la pared con los tornillos suministrados. Asegúrese de que la placa de
montaje esté plana contra la pared.
Nota: Si la pared está hecha de ladrillo, concreto o material similar, taladre orifi cios de 5 mm (0,2
pulgadas) De diámetro en la pared e inserte los anclajes de manguito suministrados. Asegure la placa de
montaje a la pared apretando los tornillos en los anclajes tipo clip.
Dimensiones de la placa de montaje
Los diferentes modelos tienen diferentes placas de montaje.
Para asegurarse de que haya espacio sufi ciente para montar
la unidad interior, verifi que los diagramas que se muestran a
continuación, los cuales muestran los dos tipos diferentes de
placas de montaje con las siguientes dimensiones:
Ancho de la placa de montaje.
Alto de la placa de montaje.
Ancho de la unidad interior respecto a la placa de montaje.
Alto de la unidad interior respecto a la placa de montaje.
Posición recomendada del orifi cio de la pared, tanto a la
izquierda como a la derecha de la unidad interior.
Distancia relativa entre los orifi cios de los tornillos.
INSTRUCCIONES DE INSTALACIÓN
10.1 cm (4”)
17.9 cm (7.05”)
13.6 cm (5.35”)
3.7 cm (1.45”)
29 cm (11.4”)
4.9 cm (1.95”)
Orificio de la
pared trasera
derecha
6.5 cm (2.5”)
Esquema de la
unidad interior
72.2 cm (28.45”)
4.9 cm (1.95”)
22.8 cm (8.98”)
22.9 cm (9.01”)
40.1 cm (15.78”)
12.6 cm (4.96”)
4.2 cm (1.65”)
29.7 cm (11.7”)
Orificio de la
pared trasera
izquierda
6.5 cm (2.5in)
80.2 cm (31.6”)
5.8 cm (2.28”)
4.7 cm (1.85”)
Modelo B
Modelo A
34.8 cm (13.7”)
Esquema de la
unidad interior
Orificio de la
pared trasera
izquierda
6.5 cm (2.5in)
Orificio de la
pared trasera
derecha
6.5 cm (2.5”)
69
Paso 3: Perforar en pared un orifi cio para la conexión de la tubería
Se debe perforar un orifi cio a través de la pared hacia el exterior para acomodar la tubería del
refrigerante, la tubería del drenaje y el cable de señalización/control que conectará las unidad interior y la
unidad exterior.
1. Determine la ubicación del orifi cio de la pared en base a la posición de la placa de montaje. Consulte
el Paso 2 para ver las dimensiones de la placa de montaje.
2. El orifi cio en la pared debe tener un diámetro de 65 mm (2,5 pulgadas) Y debe perforarse en ángulo
hacia abajo para facilitar el drenaje. El extremo exterior del orifi cio debe ser inferior al extremo interior
del orifi cio de 5 a 7 mm (0,2 - 0,275 pulgadas).
3. Coloque una banda de protección en el orifi cio. Esto protegerá los bordes del orifi cio y ayudará a
sellar el orifi cio una vez que se complete la instalación.
Nota: Al perforar el orifi cio en la pared, asegúrese de evitar hacer contacto con cables, plomería u otros
componentes sensibles que podrían estar instalados dentro de la pared.
INSTRUCCIONES DE INSTALACIÓN
70
Paso 4: Prepare tuberías del refrigerante
La tubería del refrigerante está dentro de un paquete aislante unido a la parte
posterior de la unidad. La tubería debe estar preparada antes de pasarla a
través del orifi cio en la pared. Consulte la sección Conexión de la tubería
del Refrigerante para obtener instrucciones detalladas sobre los requisitos de
ensanchamiento de la tubería y requerimientos de torsión, etc.
1. Basándose en la posición del orifi cio en la pared con respecto a la placa de
montaje, elija el lado desde el cual la tubería saldrá de la unidad.
2. Si el orifi cio de la pared está detrás de la unidad, deje el panel de
desmontaje en su lugar. Si el orifi cio en la pared está al lado de la unidad
interior, retire el panel de desmontaje de plástico del lado de la unidad. Esto
creará una ranura a través de la cual la tubería puede salir de la unidad.
Utilice pinzas de punta si el panel de plástico es difícil de quitar.
Panel de expulsión
3. Use tijeras para cortar la longitud del paquete aislante para revelar aproximadamente 15 cm (6
pulgadas) de la tubería del refrigerante. Esto tiene dos propósitos:
Para facilitar el proceso de conexión de tuberías del refrigerante
Para facilitar la detección de fugas de gas y permitir una detección de posibles abolladuras en el tubo
4. Si ya existe una tubería de conexión incrustada en la pared, proceda directamente al Paso 5: Conecte
la manguera de desagüe. Si no hay tubería incrustada, conecte la tubería del refrigerante de la unidad
interior a la tubería de conexión que unirá las unidades interiores y exteriores.
5. De acuerdo en la posición en el orifi cio de la pared respecto a la placa de montaje, determine el
ángulo necesario de la tubería. Agarre las tuberías del refrigerante en la base de la curva.
6. Lentamente, aplicando una presión uniforme, doble la tubería hacia el orifi cio en la pared. No doblar o
dañar la tubería durante el proceso.
Nota sobre el ángulo de tubería
La tubería de refrigerante puede salir de la unidad interior desde cuatro ángulos diferentes:
• Lado izquierdo
• Izquierda trasera
• Lado derecho
• Izquierda trasera
PRECAUCIÓN
Tenga mucho cuidado de no abollar o dañar la tubería
mientras la dobla lejos de la unidad. Cualquier abolladura en
la tubería afectará el rendimiento de la unidad.
INSTRUCCIONES DE INSTALACIÓN
71
Paso 5: Conecte la manguera de desagüe (drenaje)
Por defecto, la manguera de desagüe está conectada al lado izquierdo de la unidad, cuando se mira
hacia la parte posterior de la unidad. También se puede fi jar a la derecha.
1. Para asegurar un drenaje adecuado, coloque la manguera de desagüe en el mismo lado de la unidad
que la tubería del refrigerante.
2. Conecte la extensión de la manguera de desagüe (se vende por separado) al extremo de la manguera
de desagüe.
3. Use cinta de tefl ón y envuelva el punto de conexión fi rmemente para asegurar un buen sellado y evitar
fugas.
4. Para la parte de la manguera de desagüe que permanecerá en el interior, envuélvala con aislamiento
de tuberías (espuma de polietileno) para evitar la condensación.
5. Retire el fi ltro de aire y vierta una pequeña cantidad de agua en la bandeja de drenaje para asegurarse
de que el agua fl uye al exterior de la unidad con facilidad.
Nota sobre la colocación de la manguera de desagüe
Do not kink the drain hose.
No doble la manguera de desagüe.
No cree una trampa de agua.
No coloque el extremo de la manguera de desagüe en agua o en un recipiente que recoja agua.
Nota: Para prevenir fugas no deseadas, enchufe el tapón de goma suministrado en el orifi cio de drenaje
sin usar.
Vea a continuación ejemplos para instalación correcta de la manguera de desagüe:
INSTRUCCIONES DE INSTALACIÓN
72
ANTES DE REALIZAR EL TRABAJO ELECTRICO, LEA ESTAS NORMAS Y REGLAMENTOS
1. Todo el cableado debe cumplir con los códigos eléctricos locales/nacionales y debe ser instalado por
un electricista califi cado.
2. Todas las conexiones eléctricas deben realizarse de acuerdo al Diagrama de Conexión Eléctrica
ubicado en los paneles de las unidades interior y exterior.
3. Si encuentra algún problema de seguridad grave con la fuente de alimentación, pare el trabajo
inmediatamente. Explique su razonamiento al cliente y no instale la unidad hasta que se resuelva el
problema de seguridad.
4. El voltaje de alimentación eléctrica debe estar en el 90 - 100% del voltaje especifi cada. Una fuente de
alimentación insufi ciente puede causar un mal funcionamiento, una descarga eléctrica o un incendio.
5. Si conecta la energía al cableado fi jo, instale un protector contra sobretensión y un interruptor de
alimentación principal con una capacidad de 1.5 veces la corriente máxima de la unidad.
6. Si se conecta energía a un cableado fi jo, se debe incorporar un interruptor o disyuntor que
desconecte todos los polos y que tenga una separación de contacto de al menos 3 cm (1,8 pulgadas.)
En el cableado fi jo. El técnico cualifi cado debe utilizar un apagador o interruptor de circuito aprobado.
7. Conecte la unidad únicamente a un circuito ramal independiente. No conecte otro aparato o equipo
a ese toma corriente.
8. Asegúrese de poner a tierra correctamente la unidad.
9. Todos los cables deben estar fi rmemente conectados. Un cable fl ojo puede causar que el terminal se
sobrecaliente, lo que provoca un mal funcionamiento del producto y un posible incendio.
10. No permita que los cables se toquen o se apoyen contra la tubería del refrigerante, el compresor o
cualquier parte móvil dentro de la unidad.
ADVERTENCIA
ANTES DE REALIZAR CUALQUIER TRABAJO DE CABLEADO
ELÉCTRICO, DESCONECTE LA ENERGIA PRINCIPAL DEL SISTEMA.
ADVERTENCIA
TODO EL CABLEADO DEBE REALIZARSE DE ACUERDO AL
DIAGRAMA DE CABLEADO QUE SE ENCUENTRA EN EL INTERIOR
DE LA CUBIERTA DE CABLE DE LA UNIDAD INTERIOR. NO MEZCLE
CABLES VIVOS Y NULOS. ESTO ES PELIGROSO Y PUEDE CAUSAR
UN MAL FUNCIONAMIENTO DE LA UNIDAD.
INSTRUCCIONES DE INSTALACIÓN
INSTRUCCIONES DE INSTALACIÓN
73
Conecte el cableado a los terminales como se identifi ca con sus respectivos números coincidentes en el
bloque de terminales de las unidades interior y exterior. Por ejemplo, consulte los siguientes modelos de US:
El terminal L1 (A) en la unidad exterior debe conectarse con el terminal L1 en la unidad interior.
Pase el cable de alimentación principal por la salida de la línea inferior de la abrazadera del cable.
Uno-
d
os mo
d
e
l
os:
Modelo A
Modelo E Modelo F Modelo G
Modelo B Modelo C Modelo D
74
Paso 6: Conecte el cable de señalización/control
El cable de señalización y control permite la comunicación entre las unidades interior y exterior. Primero
debe elegir el tamaño correcto del cable antes de prepararlo para la conexión.
Tipos de cables:
Cable de alimentación interior (según corresponda): H05W-F o H05V2V2-F
Cable de alimentación exterior: H07RN-F
Cable de señalización: H07RN-F
Área mínima transversal de los
cables de alimentación y de señal
Amperios (A) AWG
10 18
13 16
18 14
25 12
30 10
ELIJA EL TAMANO/CALIBRE DEL CABLE CORRECTO
El tamaño del cable de alimentación, el cable de señalización/
control, el fusible y el interruptor necesarios está determinado por
la corriente máxima en la unidad. La corriente máxima se indica
en la placa de características situada en el panel lateral de la
unidad. Consulte esta placa de características para elegir el
cable, el fusible y el interruptor adecuados.
Tenga en cuenta las especifi caciones de los fusibles
La tarjeta de circuitos del aire acondicionado (PCB) está diseñada con un fusible para proporcionar
protección de sobre corriente. Las especifi caciones del fusible están impresas en la tarjeta de circuitos, tales
como: T3.15A / 250VAC, T5A / 250VAC, etc.
1. Prepare el cable para la conexión:
a. Usando la herramienta para pelar cables (wire stripper),
desmonte la cubierta de plástico de ambos extremos del cable
de señalización hasta pelar unos 40 mm (1,57 in) del interior del cable.
b. Tire el aislamiento de los extremos de los cables.
c. Usando una herramienta para prensar terminales de cable
(Wire crimper Tool) , prense las terminales tipo “u “en los
extremos de los cables.
2. Abra el panel frontal de la unidad interior.
3. Con un destornillador, abra la tapa de la caja del cableado
en el lado derecho de la unidad. Esto revelará el bloque de
terminales.
4. Desenrosque la abrazadera de cable debajo del bloque de terminales y colóquela a un lado.
5. Mirando la parte posterior de la unidad, retire el panel de plástico localizado en la parte inferior
izquierda.
6. Pase el cable de señalización y control a través de esta ranura, desde la parte posterior de la unidad
hacia el frente.
7. Mirando la parte frontal de la unidad, combine los colores de los hilos con las etiquetas en el bloque de
terminales, conecte la u-lug y atornille fi rmemente cada cable a la terminal correspondiente.
8. Después de comprobar que todas las conexiones estén bien aseguradas, utilice la abrazadera para
sujetar el cable de señalización a la unidad. Atornille fi rmemente la abrazadera del cable.
9. Vuelva a colocar la cubierta de cables en la parte frontal de la unidad y el panel de plástico en la parte
posterior.
El diagrama de cableado se encuentra
en el interior de la cubierta de cables
de la unidad interior.
Nota: Preste atención
al cable con corriente
“vivo”. Mientras prense los
alambres, asegúrese de
distinguir el alambre con
corriente –vivo- (“L”) y los
otros cables
INSTRUCCIONES DE INSTALACIÓN
75
Paso 7: Envuelva la tubería y los cables
Antes de pasar la tubería, la manguera de drenaje y el cable de señalización a través del orifi cio de la
pared, es necesario, atarlos/agruparlos, protegerlos y aislarlos de manera adecuada con la fi nalidad de
ahorrar espacio.
1. Agrupe la manguera de desagüe, las tuberías de refrigerante y el cable de señalización.
Nota: Asegúrese de que la manguera de desagüe esté en la parte inferior del paquete. La colocación de
la manguera de desagüe en la parte superior del paquete puede hacer que la bandeja de desagüe se
desborde, lo que pudiera provocar incendios o daños por agua.
2. Usando cinta adhesiva de vinilo, asegure la manguera de desagüe a la parte inferior de las tuberías de
refrigerante.
3. Usando una cinta aislante, envuelva en conjunto el cable de señalización/control, las tubería del
refrigerante y la manguera de desagüe, atándoles fi rmemente.
Nota: Mientras se agrupa estos artículos juntos, no entrelaza ni cruza el cable de la señalización/control
con cualquier otro cableado.
Nota: Al agrupar mantenga los extremos de la tubería sin envolver. Ya que se requiere de su acceso para
verifi car si hay fugas al fi nal del proceso de instalación.
INSTRUCCIONES DE INSTALACIÓN
76
Paso 8: Montaje de la unidad interior
Si se instaló una nueva tubería de conexión en la unidad exterior, complete lo siguiente:
1. Si la tubería del refrigerante ya ha pasado a través de la pared, continúe con el paso 4.
2. De lo contrario, verifi que que los extremos de los tubos de refrigerante estén sellados para evitar que
polvo o materiales extraños entren en las tuberías.
3. Pase lentamente el paquete envuelto de tuberías del refrigerante, la manguera de desagüe y el cable de
señalización/control a través del orifi cio de la pared.
4. Enganche la parte superior de la unidad interior en el gancho superior de la placa de montaje.
5. Compruebe que la unidad esté enganchada fi rmemente en el montaje aplicando una ligera presión en
ambos lados izquierdo y derecho de la unidad. La unidad no debería de moverse o voltearse.
6. Utilizando una presión uniforme, empuje hacia abajo la mitad inferior de la unidad. Mantenga
presionando hacia abajo hasta que la unidad encaje en los ganchos a lo largo de la parte inferior de
la placa de montaje.
7. Compruebe que la unidad esté fi rmemente montada aplicando una ligera presión a los lados izquierdo
y derecho de la unidad.
Si la tubería del refrigerante ya está incrustada en la pared, complete lo siguiente:
1. Enganche la parte superior de la unidad interior en el gancho superior de la placa
de montaje.
2. Utilice un soporte o una cuña para apoyar la unidad, dejando sufi ciente espacio
para conectar la tubería del refrigerante, el cable de señalización/control y la
manguera de desagüe
3. Conecte la manguera de desagüe y la tubería del refrigerante. Consulte la
sección Conexión de la tubería del refrigerante para obtener más información.
4. Mantenga el punto de conexión/unión de la tubería expuesto; a modo de poder
realizar la prueba de fugas. Consulte la sección Comprobaciones eléctricas y
Verifi cación de fugas para obtener más información.
5. Después de realizar la verifi cación de fugas, envuelva el punto de conexión/
uniones con cinta aislante.
6. Retire el soporte o la cuña que esta sosteniendo la unidad.
7. Utilizando una presión uniforme, empuje hacia abajo la mitad de la parte inferior
de la unidad. Mantenga presionando hacia abajo hasta que la unidad encaje en
los ganchos a lo largo de la parte inferior de la placa de montaje.
La unidad es Ajustable
Los ganchos de la placa de montaje son más pequeños que los agujeros en la parte posterior de la unidad.
La unidad tiene una holgura de ajuste a la izquierda o a la derecha en aproximadamente 30 - 50 mm
(1,25 - 1,95 in) dependiendo del modelo.
Cuña
INSTRUCCIONES DE INSTALACIÓN
77
INSTALACION DE LA UNIDAD EXTERIOR
Paso 1: Seleccione la ubicación de instalación
Antes de instalar la unidad exterior, elija una ubicación apropiada para la unidad. Los lugares de
instalación adecuados cumplen con los siguientes requisitos:
Buena ventilación y circulación de aire
Firme y sólido; La ubicación debe poder soportar el peso de la unidad y prevenir vibración
El ruido producido por la operación de la unidad no será molesto.
La unidad deberá estar protegida de períodos prolongados a la exposición directa de luz solar, lluvia o
nieve.
La ubicación debe cumplir con los requisitos especiales que se describen a continuación:
No instale la unidad en los siguientes lugares:
Cerca de obstáculos bloqueando las entradas o salidas de aire.
Cerca de una calle pública, en áreas con mucha gente o donde el ruido de la unidad pudiera molestar
a otros.
Cerca de animales o plantas que pudieran resultar dañados por la descarga de aire caliente.
Cerca de cualquier fuente de gas combustible.
En lugares expuesto a grandes cantidades de polvo.
En lugares expuesto a grandes cantidades de aire o ambiente con sal.
Consideraciones especiales para instalación en climas extremos
En caso de que la unidad está expuesto a fuertes vientos, instale la unidad de modo que el ventilador de
salida de aire esté en un ángulo de 90 ° con la dirección del viento. Si es necesario, construya una barrera
delante de la unidad para protegerla del viento.
En caso de que la unidad está expuesta a fuertes lluvias o nieve, construya un refugio sobre la unidad para
protegerla de la lluvia o la nieve. Tenga cuidado de no obstruir el fl ujo de aire alrededor de la unidad.
En caso de que la unidad está expuesta al aire o ambiente salado, utilice una unidad exterior
especialmente diseñada para resistir la corrosión.
INSTRUCCIONES DE INSTALACIÓN
78
Paso 2: Instale la junta/unión de drenaje
Antes de atornillar la unidad exterior en su lugar, instale la junta/unión de drenaje en la parte inferior de la
unidad. Hay dos tipos de juntas de drenaje dependiendo del tipo de unidad.
1. Coloque la sello/tapón de goma en el extremo de la junta/unión del drenaje que se conectará a la
unidad exterior.
2. Inserte la junta/unión de drenaje en el orifi cio de la base de la unidad.
3. Gire la junta de drenaje 90 ° hasta que encaje en su sitio mirando la parte frontal de la unidad.
4. Conecte una extensión de manguera de desagüe (no incluida) a la junta de drenaje para redirigir el
agua de la unidad durante su operación en modo de calefacción.
El orifi cio de la base de la junta/unión de drenaje se encuentra en la parte inferior de la unidad.
Nota para Climas Fríos
En climas fríos, asegúrese de que la manguera de desagüe esté lo más cerca posible a la posición vertical
para favorecer el drenaje rápido del agua. Si el agua se drena muy lentamente puede congelarse dentro
de la manguera de desagüe e inundar la unidad.
INSTRUCCIONES DE INSTALACIÓN
79
Paso 3: Anclaje de la unidad exterior
La unidad exterior se puede anclar al suelo o algún soporte montado en la pared.
La siguiente es una lista de tamaños de unidad exterior y la distancia en pies para su montaje. Prepare la
base de instalación de la unidad de acuerdo con las dimensiones e imágenes a continuación.
Si la unidad va a ser montada a nivel de piso, siga las siguientes instrucciones:
1. Marque las posiciones para cuatro pernos de expansión basándose en las dimensiones en el cuadro de
medidas de montaje de la unidad.
2. Pre-perforar los orifi cios para los pernos de expansión.
3. Despeje el polvo de concreto de los orifi cios.
4. Coloque una tuerca en el extremo de cada perno de expansión.
5. Usando un martillo, golpee los pernos de expansión en los orifi cios previamente perforados.
6. Retire las tuercas de los pernos de expansión y coloque la unidad exterior sobre los pernos.
7. Coloque la arandela en cada perno de expansión y luego cambie las tuercas.
8. Utilizando una llave, apriete cada tuerca hasta que quede ajustada.
ADVERTENCIA
Al perforar el concreto, se
debe usar protección ocular
en todo momento.
Si la unidad va a montarse en la pared, siga las siguientes instrucciones:
1. Marque las posiciones de los orifi cios de los soportes según las dimensiones en el cuadro de dimen-
siones de montaje de la unidad.
2. Pre-perforar los orifi cios para los pernos de expansión.
3. Limpie el polvo de concreto de los orifi cios.
4. Coloque una arandela y una tuerca en el extremo de cada perno de expansión.
5. Usando un martillo, golpee los pernos de expansión a través de los orifi cios de los soportes de montaje,
coloque los soportes de montaje en posición y golpee los pernos de expansión en la pared.
6. Compruebe que los soportes de montaje están nivelados.
7. Levante con cuidado la unidad y coloque las bases de montaje en los soportes.
8. Atornille fi rmemente la unidad a los soportes.
Nota: Para reducir las vibraciones y el ruido de una unidad montada en la pared, instale la unidad con
juntas/empaques de goma.
Diagrama de dimensiones de montaje de unidad
Número de modelo
Dimensiones de la unidad
(Anchura x Altura x Profundidad)
Distancia A
(mm / pulg)
Distancia B
(mm / pulg)
DAS180DBAHWDB 922x715x379 (36.3”x28.2”x14.9”) 540 (21.26”) 350 (13.8”)
INSTRUCCIONES DE INSTALACIÓN
80
Paso 4: Conecte los cables de señalización/control y de alimentación
El bloque de conexiones terminales de las unidades exteriores está protegido por una cubierta para el
cableado eléctrico en la parte lateral de la unidad. Un diagrama completo del cableado está impreso en el
interior de la cubierta del cableado.
Tipos de cables:
Cable de alimentación interior (según corresponda): H05V-F o H05V2-F
Cable de alimentación exterior: H07RN-F
Cable de señal: H07RN-F
1. Prepare el cable para la conexión:
a. Usando la herramienta para pelar cables (wire stripper), desmonte la cubierta de plástico de
ambos extremos del cable de señalización hasta pelar unos 40 mm (1,57 in) del interior del cable.
b. Tire el aislamiento de los extremos de los cables.
c. Usando una herramienta para prensar terminales cable (Wire crimper Tool) , prense las terminales
tipo “u “en los extremos de los cables.
Nota: Preste atención al cable con corriente “vivo”. Mientras prense los alambres, asegúrese de distinguir el
alambre con corriente –vivo- (“L”) y los otros cables.
2. Desatornille la cubierta del cableado eléctrico y retírela.
3. Desatornille la abrazadera de cable debajo del bloque de terminales y colóquela a un lado.
4. Haga coincidir los colores y las etiquetas de los cables con las etiquetas en el bloque de terminales y
atornille fi rmemente la u-lug de cada cable a su terminal correspondiente.
5. Después de verifi car para asegurarse de que cada conexión es segura, haga un lazo alrededor de los
cables para evitar que el agua de lluvia fl uya hacia el terminal.
6. Con la abrazadera del cable, sujete el cable a la unidad. Atornille fi rmemente la abrazadera del cable.
7. Aísle los cables no utilizados con cinta aislante de PVC. Organizarlos para que no toquen ninguna
parte eléctrica o de metal.
8. Vuelva a colocar la cubierta del cable en el lado lateral de la unidad y atorníllela en su lugar.
Área mínima transversal
de los cables de
alimentación y de señal
Amperios (A) AWG
10 18
13 16
18 14
25 12
30 10
ADVERTENCIA
Todo el cableado debe realizarse de acuerdo con el diagrama de
cableado que se encuentra en el interior de la cubierta de cableado
de la unidad exterior. No mezcle cables con corriente “vivos” y nulos.
Esto es peligroso y puede causar un mal funcionamiento del aparato.
El diagrama de cableado se
encuentra en el interior de la cubierta
del cableado de la unidad exterior
INSTRUCCIONES DE INSTALACIÓN
81
CONEXIÓN DE TUBERÍA DEL REFRIGERANTE
La longitud de la tubería del refrigerante afectará el rendimiento y la efi ciencia energética de la unidad. La
efi ciencia nominal es probada en unidades con una longitud de tubería de 5 m (16,5 pies).
INSTRUCCIONES DE CONEXIÓN - TUBERÍA DEL REFRIGERANTE
Paso 1: Corte las tuberías
Cuando prepare tuberías del refrigerante, tenga mucho cuidado en cortarlas y ensancharlas
adecuadamente (mediante herramienta para ensanchar tubería – Tube Flaring Tool de su nombre en Ingles) .
Esto garantizará un funcionamiento efi ciente y minimizará la necesidad de mantenimiento futuro.
1. Mida la distancia entre las unidades interior y exterior.
2. Utilizando una herramienta para cortar de tubería, corte el tubo un poco más largo que la distancia
medida.
3. Asegurarse de que la tubería se corte a 90 °.
Nota: No dañar, doblar o deformar el tubo mientras se corta. Esto reducirá drásticamente la efi ciencia de
calentamiento de la unidad.
Paso 2: Retirar las rebabas (residuos de metal)
Las rebabas pueden afectar el sellado hermético
de la conexión de la tubería del refrigerante. Las
rebabas deben ser eliminadas por completo.
1. Sujete el tubo en un ángulo hacia abajo para
evitar que las rebabas caigan en el tubo.
2. Utilizando un escariador o herramienta para
eliminar rebaba, quite todas las rebabas de
la sección cortada del tubo.
INSTRUCCIONES DE INSTALACIÓN
82
Paso 3: Ensanche los extremos de la tubería (puntas de la tubería)
El ensanchamiento adecuado es esencial para lograr un sello hermético.
1. Después de eliminar las rebabas de la tubería que se corto, sellar los extremos con cinta de PVC para
evitar que los materiales extraños entren en la tubería.
2. Envuelva el tubo con material aislante.
3. Coloque las tuercas cónicas en ambos extremos del tubo. Asegúrese de que están mirando en la
dirección correcta, ya que no se pueden quitar o ajustar después de la tubería se ha ensanchado.
4. Retire la cinta de PVC de los extremos de la tubería cuando esté lista para realizar trabajos de
ensanchado.
5. Abra la abrazadera en el extremo de la tubería. El extremo del tubo debe extenderse más allá del
borde de la forma ensanchada de acuerdo con las dimensiones mostradas en la tabla y la imagen de
abajo.
6. Coloque en el lugar la herramienta de ensanchamiento de tubería.
7. Gire el asa de la herramienta de ensanchamiento en el sentido de las agujas del reloj hasta que el tubo
esté completamente ensanchado
8. Retire la herramienta de ensanchamiento de tubería, a continuación, inspeccione el extremo de la
tubería para comprobar si hay grietas e incluso si se realizo un ensanchamiento uniforme.
EXTENSIÓN DE TUBERÍA MÁS ALLÁ DEL FORMULARIO FLARE
Diámetro exterior del tubo (mm) Dimensión A Mínima (mm) Dimensión A Máximo (mm)
Ø 6.35 (Ø 0.25 pulgada) 0.7 (0.0275 pulgada) 1.3 (0.05 pulgada)
Ø 9.52 (Ø 0.375 pulgada) 1.0 (0.04 pulgada) 1.6 (0.063 pulgada)
Ø 12.7 (Ø 0.5 pulgada) 1.0 (0.04 pulgada) 1.8 (0.07 pulgada)
Ø 16 (Ø 0.63 pulgada) 2.0 (0.078 pulgada) 2.2 (0.086 pulgada)
INSTRUCCIONES DE INSTALACIÓN
83
Paso 4: Conecte las tuberías
Al conectar tuberías de refrigerante, tenga cuidado de no utilizar un fuerza o
torsión en exceso, ni deformar la tubería de ninguna manera. Conecte primero
el tubo de baja presión y después conecte el tubo de alta presión.
Nota: Cuando dobla la conexión de tubería del refrigerante, el radio de
curvatura mínimo es de 10 cm (3.9 in).
CONEXIÓN DE LA TUBERÍA A LA UNIDAD INTERIOR
1. Alinee el centro de los dos tubos que se conectarán.
2. Apriete la tuerca cónica tan fi rmemente como sea posible con la mano.
3. Con una llave, sujete la tuerca en el tubo de la unidad.
4. Mientras sujeta fi rmemente la tuerca en el tubo de la unidad, utilice una llave de torsión para apretar la
tuerca cónica de acuerdo con los valores de torsión en la tabla de requerimientos de torsión que se dan
a continuación. Afl oje ligeramente la tuerca cónica y luego apriete de nuevo.
REQUISITOS DE TORQUE
Diámetro exterior del tubo (mm) Pares de apriete (N•cm) Pares de apriete adicionales (N•m)
Ø 6.35 (Ø 0.25 in) 1,500 (11 lb•ft) 1,600 (11.8 lb•ft)
Ø 9.52 (Ø 0.375 in) 2,500 (18.4 lb•ft) 2,600 (19.18 lb•ft)
Ø 12.7 (Ø 0.5 in) 3,500 (25.8 lb•ft) 3,600 (26.55 lb•ft)
Ø 16 (Ø 0.63 in) 4,500 (19 lb•ft) 4,700 (34.67 lb•ft)
Una fuerza excesiva puede romper
la tuerca o dañar la tubería del
refrigerante. No exceder los
requerimientos de torsión que se
muestran en la siguiente tabla.
INSTRUCCIONES DE INSTALACIÓN
84
CONEXIÓN DE LA TUBERÍA A LA UNIDAD EXTERIOR
1. Desatornille la tapa de la válvula empaquetada en un lado de la unidad exterior.
2. Retire las tapas protectoras de los extremos de las válvulas.
3. Alinee el extremo del tubo ensanchado con cada válvula y apriete la tuerca cónica tan fi rmemente como
sea posible con la mano.
4. Con una llave, sujete el cuerpo de la válvula. No agarre la tuerca que sella la válvula de servicio.
5. Mientras sujeta fi rmemente el cuerpo de la válvula, utilice una llave de torsión para apretar la tuerca
cónica de acuerdo con los valores de tosían correctos.
6. Afl oje ligeramente la tuerca cónica y vuelva a apretarla de nuevo.
7. Repita los pasos 3 a 6 para el tubo restante.
INSTRUCCIONES DE INSTALACIÓN
85
EXTRACCION/PURGA DEL AIRE
Preparaciones y Precauciones
El aire, humedad y materias extrañas en el sistema de refrigeración pueden causar aumentos anormales en
la presión, lo que puede dañar el aire acondicionado, reducir su efi ciencia y causar lesiones. Utilice una
bomba de vacío y un manómetro de colector para purgar el sistema de refrigeración, eliminando cualquier
gas no condensable (Aire) y la humedad del sistema.
La extracción/purga debe realizarse durante la instalación inicial y cuando la unidad sea transportada o
trasladada.
Antes de realizar la extracción/purga:
Compruebe que tanto la tubería de alta presión como la de baja presión entre las unidades interior y
exterior estén correctamente instaladas.
Compruebe que todos los cables estén conectados correctamente.
Instrucciones de evacuación
Antes de utilizar el juego de manómetros y la bomba de vacío, lea sus manuales de operación para
asegurarse de que se están usando correctamente.
INSTRUCCIONES DE INSTALACIÓN
86
Instrucciones de extracción/purga
1. Conecte la manguera de carga del manómetro al puerto de servicio de la válvula de baja presión
localizado en la unidad exterior.
2. Conecte otra manguera de carga del manómetro a la bomba de vacío.
3. Abra el lado de baja presión del manómetro múltiple. Mantenga el lado de alta presión cerrado.
4. Encienda la bomba de vacío para purgar el sistema.
5. Deje en operación la bomba de vacío durante al menos 15 minutos o hasta que el medidor compuesto
lea -76cmHG (-105 Pa).
6. Cierre el lado de baja presión del manómetro múltiple y apague la bomba de vacío.
7. Espere 5 minutos y verifi que que no ha habido cambios en la presión del sistema.
8. Si hay un cambio en la presión del sistema, consulte la sección Comprobación de fugas de gas para
obtener información sobre cómo verifi car si el sistema tiene fugas. Si no hay ningún cambio en la
presión del sistema, desenrosque la tapa de la válvula de alta presión empaquetada.
9. Inserte la llave hexagonal en la válvula de alta presión empacada y abra la válvula girando la llave
en un giro de 1/4 en el sentido de las agujas del reloj. Escuche cuando el gas sale del sistema, luego
cierre la válvula después de 5 segundos.
10. Observe el indicador de presión durante 1 minuto para asegurarse de que no hay cambio en la
presión. La lectura en el manómetro debería ser un poco más alto que la presión atmosférica.
11. Retire la manguera de carga del puerto de servicio.
12. Con una llave hexagonal, abra completamente ambas válvulas de alta presión y baja presión.
13. Apriete manualmente las tapas de las válvulas en las tres válvulas (puerto de servicio, alta presión y
baja presión). Apriete con una llave de torsión en caso de ser necesario.
ADVERTENCIA
CUIDADO DE
NO MEZCLAR
DIFERENTES TIPOS DE
REFRIGERANTES
INSTRUCCIONES DE INSTALACIÓN
Refrigerante adicional por longitud de tubo
Longitud de tubo
conectivo (m)
Método de
purga de aire
Refrigerante adicional
< Longitud de
tubería estándar
Bomba
aspiradora
N/A
> Longitud de
tubería estándar
Bomba
aspiradora
Lado líquido: Ø 6.35 (ø 0.25 in)
Inversor R410a:
(Longitud del tubo - LTE) x 15g/m
(Longitud del tubo - LTE) x 0.16oZ/ft
Lado líquido: Ø 9.52 (ø 0.375 in)
Inversor R410a:
(Longitud del tubo - LTE) x 30g/m
(Longitud del tubo - LTE) x 0.32oZ/ft
87
Nota: Abra despacio el vástago de la válvula. Para abrir los vástagos de la válvula, gire la llave hexagonal
hasta que golpee contra el tope. No intente forzar la válvula a abrirse mas de lo debido.
Nota: Algunos sistemas requieren una carga adicional dependiendo de las longitudes de tubería. La
longitud estándar de la tubería varía según las regulaciones locales. Por ejemplo, en Norteamérica, la
longitud estándar del tubo es de 7,5 m (25 pies). En otras áreas, la longitud estándar del tubo es de 5 m
(16 pies). El refrigerante adicional que debe cargarse se puede calcular utilizando la fórmula del siguiente
gráfi co.
LTE = Longitud de tubería estándar
INSTRUCCIONES DE INSTALACIÓN
88
COMPROBACION ELÉCTRICA Y VERIFICACION DE FUGAS DE GAS
Comprobaciones de seguridad eléctrica
Después de la instalación, confi rme que todos los cables eléctricos están instalados de acuerdo con las
regulaciones locales / nacionales y de acuerdo con el manual de instalación.
Verifi cación del trabajo de puesta a tierra
Antes de completar una prueba, mida la resistencia a tierra mediante detección visual y con un
comprobador de resistencia a tierra. La resistencia de puesta a tierra debe ser inferior a 4.
Verifi cación de fugas eléctricas
Durante la prueba, utilice un probador eléctrico y un multímetro para realizar una prueba exhaustiva de fuga
eléctrica.
Si se detecta una fuga eléctrica, apague la unidad inmediatamente y llame a un electricista certifi cado para
encontrar y resolver la causa de la fuga.
Verifi cación de Fugas de Gas
Existen dos métodos aceptables para verifi car fugas de gas.
Método de jabón y agua
Con un cepillo suave o esponja, aplique agua jabonosa o detergente líquido a todos los puntos de
conexión de tubería, tanto en las unidad interior y exterior. La presencia de burbujas será una indicación
una fuga.
Método del detector de fugas
Si utiliza un detector de fugas, consulte el manual de operación del dispositivo para obtener las
instrucciones de uso adecuadas.
Nota: Después de completar las verifi caciones de fugas de gas, confi rme que no hay fugas en todos
los puntos de conexión de la tubería y asegúrese de reemplazar la cubierta de las válvulas en la unidad
exterior.
ADVERTENCIA
All wiring must comply with local and
national electrical codes and must be
installed by a licensed electrician.
INSTRUCCIONES DE INSTALACIÓN
PRUEBA DE FUNCIONAMIENTO
Antes de completar una prueba funcionamiento, asegúrese de completar todas las comprobaciones de
seguridad eléctrica y verifi cación de fugas de gas. Confi rme que el sistema eléctrico de la unidad es seguro
y funciona correctamente. Compruebe todas las conexiones en tubería con tuerca cónica y confi rme que el
sistema no tiene fugas.
Instrucciones para la prueba de funcionamiento
1. Conecte la alimentación eléctrica a la unidad.
2. Presione el botón ON / OFF del mando a distancia (Control Remoto) para encender la unidad.
3. Pulse el botón MODE para desplazarse por las siguientes funciones:
COOL - seleccione la temperatura más baja posible
HEAT - seleccione la temperatura más alta posible
4. Permita que cada función funcione durante 5 minutos y realice las siguientes comprobaciones:
No hay fugas eléctricas
La unidad está debidamente conectada a tierra
Todos los terminales eléctricos están debidamente cubiertos
La unidad interior y exterior están bien instaladas y aseguradas.
Todos los puntos de conexión de la tubería no presentan fugas,
El agua drena correctamente por la manguera de desagüe
Toda la tubería está correctamente aislada (uso de aislante)
La unidad realiza correctamente la función COOL (FRIO)
La unidad realiza correctamente la función HEAT (CALOR)
Las rejillas de la unidad interior giran correctamente
La unidad interior responde al mando a distancia (Control Remoto)
IMPORTANTE: Durante el funcionamiento, la presión del sistema refrigerante aumentará. Esto puede revelar
fugas que no estuvieron presentes durante la verifi cación inicial de fugas. Tome tiempo durante la prueba
de funcionamiento, para verifi car que todos los puntos de conexión de la tubería del refrigerante no tengan
fugas.
5. Una vez terminada la prueba de funcionamiento, utilice el mando a distancia (Control Remoto) para
volver a la temperatura normal de funcionamiento. Usando cinta aislante, envuelva las conexiones de
la tubería del refrigerante en la unidad que quedaron sin cubrir durante el proceso de instalación de la
unidad interior.
Prueba de funcionamiento a baja temperatura
Si la temperatura ambiente es inferior a 17 °C (62.6 °F), la función COOL no funcionará cuando se utili-
za el mando a distancia (Control Remoto). En este caso, utilice el botón de control manual para probar la
función COOL.
1. 1. Levante el panel frontal de la unidad interior y levántelo hasta que encaje en su lugar.
2. 2. El botón de control manual se encuentra en el lado derecho de la unidad. Pulse dos veces para
seleccionar la función COOL.
3. 3. Lleve a cabo la prueba de funcionamiento de manera normal.
Directrices para la eliminación
Este aparato contiene refrigerante y otros materiales potencialmente peligrosos. Al deshacerse de este
aparato, la ley requiere una recogida y tratamiento especiales. No deseche este electrodoméstico como
basura doméstica o residuos municipales no clasifi cados.
89
INSTRUCCIONES DE INSTALACIÓN
LIMITED IN-HOME APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating
conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter
“Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
First Year
During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the ORIGINAL purchaser.
To obtain
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance
Service
requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at
their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below.
Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service
must be performed by a qualied service technician.
If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all
obligations of Danby under this warranty shall be void.
Boundaries of
If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be
In Home Service
delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for
warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he
responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due
to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its
authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees
under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages
to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of
the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions
(extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application).
Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our
AUTHORIZED SERVICE DEPOT.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
04/09
1-800-263-2629
Warranty Service
In-home
Durante los primeros veinticuatro (24) meses, cualquier parte en buen estado de este producto que
resulte defectuosa, incluyendo cualquier sistema sellado, será reparado o reemplazado, a opción
del fabricante, sin cargo para el comprador ORIGINAL.
Primeros 24 meses
GARANTÍA LIMITADA DEL APARATO
Este producto de calidad está garantizado contra defectos de fabricación, incluyendo partes y mano de obra, siempre y
cuando la unidad se utilice bajo las condiciones normales de funcionamiento para las que fue diseñado.
Esta garantía está solamente disponible para la persona que haya comprado originalmente esta unidad directamente
de Danby Products Limited (Canada) o Danby Products Inc. (U.S.A.) (en adelante “Danby”) o uno de sus distribuidores
autorizados, y no es transferible.
CONDICIONES DE LA GARANTÍA
Las piezas plásticas, se autorizan por treinta (30) días solamente a partir de la fecha de la compra, sin las extensiones
proporcionadas.
Nada dentro de esta garantía implica que Danby será responsable por cualquier daño que hayan sufrido los alimentos
u otros contenidos de este aparato, ya sea debido a un defecto del aparato, o su uso, adecuado o inadecuado.
EXCLUSIONES
Salvo lo aquí indicado por Danby, no existen otras garantías, condiciones o representaciones, explícitas o implícitas,
concretas o intencionales por parte de Danby o sus distribuidores autorizados y todas las demás garantías, condi-
ciones o representaciones, incluyendo cualquier garantía, condiciones o representaciones bajo cualquier Acta de Venta
de Productos o legislación o estatuto similar, quedan de esta forma expresamente excluidas. Salvo lo aquí indicado,
Danby no serán responsables por ningún daño a personas o bienes, incluyendo la propia unidad, sin importar su
causa, o de ningún daño indirecto
causado por el desperfecto de la unidad, y al comprar esta unidad, el comprador acepta por la presente, indemnizar y
proteger a Danby contra cualquier reclamo por daños a personas o bienes causados por la unidad.
CONDICIONES GENERALES
No se considerará ninguna de estas garantías o seguros cuando el daño o la necesidad de reparación sea el producto
de los siguientes casos:
1) Falla del suministro eléctrico.
2) Daños en tránsito o durante el transporte de la unidad.
3) Alimentación incorrecta, como bajo voltaje, instalación eléctrica defectuosa o fusibles inadecuados.
4) Accidente, modificación, abuso o uso incorrecto del artefacto, tal como insuficiente ventilación del ambiente o
condiciones de operación anormales (temperatura ambiente extremadamente alta o baja).
5) Utilización comercial o industrial (v.g., si el electrodoméstico no está instalado en una vivienda particular).
6) Incendio, daños por agua, robo, guerra, disturbios, hostilidades, actos de fuerza mayor como huracanes, inunda-
ciones, etc.
7) Pedidos de servicio debido a desinformación del usuario.
8) Instalación inadecuada (v.g., instalación empotrada de un electrodoméstico diseñado como unidad independiente o
uso de un electrodoméstico al aire libre que no esté aprobado para dicho fin).
Para acceder a la garantía se solicitará un comprobante de compra; por lo tanto, guarde su recibo.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
1-800-263-2629
12/19
MODEL • MODÈLE • MODELO
Printed in China
Imprimé en Chine
Impreso en China
Danby Products Limited, Guelph, ON, Canada N1H 6Z9
Danby Products Inc., Findlay, Ohio, USA 45840
DAS090BAHWDB
DAS120BAHWDB
DAS180BAHWDB
DAS240BAHWDB

Transcripción de documentos

OWNER’S MANUAL MANUEL DU PROPRIÉTAIRE MANUAL DEL PROPIETARIO DAS180DBAHWDB SPLIT AIR CONDITIONER Installation Guide ............................................... 1 - 30 CLIMATISEUR DIVISÉ Guide d’installation........................................... 31 - 60 AIRE ACONDICIONADO DIVIDIDO Guía de instalación............................................ 61 - 90 FOR ANY QUESTIONS OR CONCERNS REGARDING INSTALLATION OR SERVICING OF THIS UNIT, PLEASE CONTACT THE DEALER OR BUILDER WHO SOLD THE UNIT. _____________________________________________________________________ POUR TOUTE QUESTION OU PRÉOCCUPATION CONCERNANT L’INSTALLATION OU L’ENTRETIEN DE CET APPAREIL, VEUILLEZ CONTACTER LE REVENDEUR OU LE CONSTRUCTEUR QUI A VENDU L’APPAREIL. __________________________________________________________________ PARA CUALQUIER PREGUNTA O INQUIETUD RELACIONADA CON LA INSTALACIÓN O SERVICIO DE ESTA UNIDAD, PÓNGASE EN CONTACTO CON EL DISTRIBUIDOR O CONSTRUCTOR QUE VENDIÓ LA UNIDAD. www.Danby.com DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9 DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840 2019.12.17 Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAFETY PRECAUTIONS • This appliance is not intended for use by persons (including children) whose physical, sensory or metal capabilities may be different or reduced, or who lack experience or knowledge, unless such persons receive supervision or training to operate the appliance by a person responsible for their safety. • Do not install the appliance in a location that may be exposed to combustible gas leaks. If combustible gas accumulates around the appliance, it may cause fire. • Do not operate this appliance in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit. • The appliance must be properly grounded or electric shock can occur. • Install drainage piping according to the instructions in this manual. Improper drainage may cause water damage. Incorrect installation due to ignoring instructions can cause serious damage or injury. • When connecting refrigerant piping, do not let substances or gases other than the specified refrigerant enter the lines as this will lower the unit’s capacity and can cause abnormally high pressure in the refrigeration system, which can lead to explosion or injury. • Installation must be performed by a certified HVAC technician. Defective installation can cause water leakage, electrical shock or fire. • In North America, installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only. • Contact an HVAC technician or the sales agent for information on repair or maintenance of this appliance. • Only use the included accessories, parts and specified parts for installation. Using nonstandard parts can cause water leakage, electrical shock, fire and can cause the unit to fail. • Install the appliance in a firm location that can support the unit’s weight. If the chosen location cannot support the appliance’s weight, or if the installation is not completed properly, the appliance may fall and cause serious injury or damage. • For all electrical work, follow all local and national wiring standards and regulations and this manual. You must use an independent circuit and single outlet to supply power. Do not connect other appliances to the same outlet. Insufficient electrical capacity or defects in electrical work can cause electrical shock or fire. • For all electrical work, use all specified cables. Connect cables tightly and clamp them securely to prevent external forces from damaging the terminal. Improper electrical connections can overheat and cause electrical shock or fire. • All wiring must be correctly arranged to ensure that the control board can close properly. If the control board cover is not closed properly, it can lead to corrosion and cause the connection points on the terminal to overheat, catch fire or cause electrical shock. • In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed air conditioning units is highly recommended. NOTE ABOUT FLUORINATED GASES • This appliance contains fluorinated gasses. For specific information on the type and amount of gas, refer to the relevant label on the appliance itself. • Installation, service, maintenance and repair of this appliance must be performed by a certified HVAC technician. • Uninstallation and recycling must be performed by a certified HVAC technician. • If the appliance has a leak detection system installed, it must be checked for leaks at least every 12 months. When the appliance is checked for leaks, proper record keeping of all checks is strongly recommended. SAVE THESE INSTRUCTIONS! 1 INSTALLATION INSTRUCTIONS ACCESSORIES The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock, fire or may cause the equipment to fail. Part Image Quantity Mounting plate 2 Mounting plate fixing screw ST3.9 x 25 10 Clip anchor 10 Remote control 2 Dry battery AAA.LR03 4 Seal 2 Drain joint 2 2 INSTALLATION INSTRUCTIONS INSTALLATION SUMMARY Wall Mounting Plate Front Panel Power Cable Louver Drainage Pipe Functional Filter On Front of Main Filter Signal Cable Refrigerant Pipe Remote Control Outdoor Unit Power Cable Note: Illustrations in this manual are for explanatory purposes only. The actual shape of the appliance may be slightly different. The actual shape shall prevail. Note: The model DAS180DBAHWDB can be attached to multiple indoor units. See the next page for details. 3 INSTALLATION INSTRUCTIONS INSTALLATION SUMMARY When installing multiple indoor units to a single outdoor unit, ensure that the length of the refrigerant pipe and the drop height between the indoor and outdoor units meet the following requirements: Outdoor Unit Indoor Unit Outdoor Unit 49ft (15m) 32.8ft (10m) 49ft (15m) Outdoor Unit Indoor units that can be used in combination Number of connected units 1 - 5 units Compressor stop/start frequency Power source voltage Stop time Voltage fluctuation Voltage drop during start Interval unbalance Units are in meters/feet Max. length for all rooms Max. length for one indoor unit Max. height difference between indoor and outdoor Max. height difference between indoor units 4 1 drive 2 40/131 25/82 15/49 10/33 3 minutes or more within ± 10% of rated voltage within ± 15% of rated voltage within ± 3% of rated voltage 1 drive 3 60/197 30/98 15/49 10/33 1 drive 4 80/262 35/115 15/49 10/33 1 drive 5 80/262 35/115 15/49 10/33 INSTALLATION INSTRUCTIONS INSTALLATION SUMMARY - INDOOR UNIT 5 INSTALLATION INSTRUCTIONS INSTALLATION SUMMARY - INDOOR UNIT 6 INSTALLATION INSTRUCTIONS INDOOR UNIT INSTALLATION Before installing the indoor unit, refer to the label on the product box to ensure that the model number on the indoor unit matches the model number on the outdoor unit. The indoor unit model number will end with a “-I” and the outdoor unit model number will end with a “-O”, otherwise they should be identical. Step 1: Select Installation Location Proper installation locations meet the following standards: • • • • • • Good air circulation. Convenient drainage. Noise from the unit will not be disturbing. Firm and solid location that will not vibrate. Strong enough to support the weight of the unit. At least 1 m (3 feet) away from all other electrical devices, such as televisions, radios and computers, which could impact the infrared remote signal. Do not install the indoor unit in locations that have the following: • • • • • Near any source of heat, steam or combustible gas. Near flammable items such as curtains or clothing. Near any obstacle that might block air circulation. Near any doorway. In direct sunlight. Refer to the below illustration to ensure proper distance from surrounding walls and ceiling: 7 INSTALLATION INSTRUCTIONS Step 2: Attach Mounting Plate To Wall The mounting plate is the device that attaches the indoor unit on the wall. 1. Remove the screw that attaches the mounting plate to the back of the indoor unit. 2. Place the mounting plate against the wall in the location where the indoor unit will be installed. 3. Drill holes for the mounting screws, ensuring that the screws enter wall studs that can support the weight of the unit. 4. Secure the mounting plate to the wall with the provided screws. Ensure that the mounting plate is flat against the wall. Note: If the wall is made of brick, concrete or similar material, drill 5 mm (0.2 in) diameter holes in the wall and insert the provided sleeve anchors. Secure the mounting plate to the wall by tightening the screws into the clip anchors. Mounting Plate Dimensions Different models have different mounting plates. To ensure that there is ample room to mount the indoor unit, check the diagrams below which show the two different types of mounting plates along with the following dimensions: • • • • • Width of mounting plate. Height of mounting plate. Width of indoor unit relative to mounting plate. Height of indoor unit relative to mounting plate. Recommended position of wall hole, both to the left and right of the indoor unit. • Relative distance between screw holes. Model B 72.2 cm (28.45”) Right rear wall hole 6.5 cm (2.5”) Left rear wall hole 6.5 cm (2.5”) 8 Indoor unit outline 80.2 cm (31.6”) 5.8 cm (2.28”) Indoor unit outline 12.6 cm (4.96”) 4.2 cm (1.65”) 22.9 cm (9.01”) 22.8 cm (8.98”) 4.9 cm (1.95”) Left rear wall hole 6.5 cm (2.5in) 13.6 cm (5.35”) 4.9 cm (1.95”) 29 cm (11.4”) 10.1 cm (4”) 40.1 cm (15.78”) 29.7 cm (11.7”) 17.9 cm (7.05”) 3.7 cm (1.45”) 34.8 cm (13.7”) 4.7 cm (1.85”) Model A Right rear wall hole 6.5 cm (2.5”) INSTALLATION INSTRUCTIONS Step 3: Drill Wall Hole For Connective Piping A hole must be drilled through the wall to the outside to accommodate the refrigerant piping, the drainage pipe and the signal cable that will connect the indoor and outdoor units. 1. Determine the location of the wall hole based on the position of the mounting plate. See Step 2 for mounting plate dimensions. 2. The wall hole should have a 65 mm (2.5 in) diameter and it should be drilled on a downward angle to facilitate drainage. The outdoor end of the hole should be lower than the indoor end of the hole by 5 - 7 mm (0.2 - 0.275 in). 3. Place the protective wall cuff in the hole. This will protect the edges of the hole and will help seal the hole once the installation is complete. Note: When drilling the wall hole, make sure to avoid wires, plumbing and other sensitive components that could be within the wall. 9 INSTALLATION INSTRUCTIONS Step 4: Prepare Refrigerant Piping The refrigerant piping is inside an insulating sleeve attached to the back of the unit. The piping must be prepared before passing it through the hole in the wall. Refer to the Refrigerant Piping Connection section for detailed instructions on pipe flaring and flare torque requirements, etc. 1. Based on the position of the wall hole relative to the mounting plate, choose the side from which the piping will exit the unit. Knock out panel 2. If the wall hole is behind the unit, leave the knock out panel in place. If the wall hole is to the side of the indoor unit, remove the plastic knock out panel from the side of the unit. This will create a slot through which the piping can exit the unit. Use needle nose pliers if the plastic panel is difficult to remove. 3. Use scissors to cut down the length of the insulating sleeve to reveal approximately 15 cm (6 in) of the refrigerant piping. This serves two purposes: • To facilitate the Refrigerant Piping Connection process • To facilitate gas leaks checks and allow a check for dents in the pipe 4. If existing connective piping is already embedded in the wall, proceed directly to Step 5: Connect The Drain Hose. If there is no embedded piping, connect the indoor unit’s refrigerant piping to the connective piping that will join the indoor and outdoor units. 5. Based on the position of the wall hole relative to the mounting plate, determine the necessary angle of the piping. Grip the refrigerant piping at the base of the bend. 6. Slowly, with even pressure, bend the piping toward the wall hole. Do not dent or damage the pipe during the process. Note on Piping Angle Refrigerant piping can exit the indoor unit from four different angles: • • • • Left-hand side Left rear Right-hand side Left rear CAUTION Be extremely careful not to dent or damage the piping while bending them away from the unit. Any dents in the piping will affect the unit’s performance. 10 INSTALLATION INSTRUCTIONS Step 5: Connect the Drain Hose By default, the drain hose is attached to the left-hand side of the unit, when facing the back of the unit. It can also be attached to the right-hand side. 1. 2. 3. 4. To ensure proper drainage, attach the drain hose on the same side of the unit as the refrigerant piping. Attach the drain hose extension (purchased separately) to the end of the drain hose. Wrap the connection point firmly with Teflon tape to ensure a good seal and prevent leaks. For the portion of the drain hose that will remain indoors, wrap it with foam pipe insulation to prevent condensation. 5. Remove the air filter and pour a small amount of water into the drain pan to make sure that water flows from the unit smoothly. Note on Drain Hose Placement • Do not kink the drain hose. • Do not create a water trap. • Do not put the end of the drain hose in water or a container that will collect water. Note: To prevent unwanted leaks, plug the unused drain hole with the provided rubber plug. See below for examples of correct drain hose installation: 11 INSTALLATION INSTRUCTIONS BEFORE PERFORMING ELECTRICAL WORK, READ THESE REGULATIONS 1. All wiring must comply with local and national electrical codes and must be installed by a licensed electrician. 2. All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units. 3. If there is a serious safety issue with the power supply, stop work immediately. Explain your reasoning to the client and refuse to install the unit until the safety issue is resolved. 4. Power voltage should be within 90 - 100% of rated voltage. Insufficient power supply can cause malfunction, electrical shock or fire. 5. If connecting power to fixed wiring, install a surge protector and main power switch with a capacity of 1.5 times the maximum current of the unit. 6. If connecting power to fixed wiring, a switch or circuit breaker that disconnects all poles and has a contact separation of at least 3 mm (1.8 in) must be incorporated in the fixed wiring. The qualified technician must use an approved circuit breaker or switch. 7. Only connect the unit to an individual branch circuit outlet. Do not connect another appliance to that outlet. 8. Make sure to properly ground the appliance. 9. Every wire must be firmly connected. Loose wiring can cause the terminal to overheat, resulting in product malfunction and possible fire. 10. Do not let wires touch or rest against the refrigerant tubing, the compressor or any moving parts within the unit. WARNING BEFORE PERFORMING ANY ELECTRICAL WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM. WARNING All wiring must be performed in accordance with the wiring diagram located on the inside of the indoor unit’s wire cover. Do not mix up live and null wires. This is dangerous and can cause the appliance to malfunction. 12 INSTALLATION INSTRUCTIONS Connect the wiring to the terminals as identified with their respective matched numbers on the terminal block of the indoor and outdoor units. For example, see the following US models: Terminal L1(A) on the outdoor unit must connect with terminal L1 on the indoor unit. Run the main power cord through the lower line outlet of the cord clamp. One-two models: Model A Model E Model B Model C Model F Model G 13 Model D INSTALLATION INSTRUCTIONS Step 6: Connect the Signal Cable The signal cable enables communication between the indoor and outdoor units. You must first choose the right cable size before preparing it for connection. Cable types: • Indoor Power Cable (if applicable): H05W-F or H05V2V2-F • Outdoor Power Cable: H07RN-F • Signal Cable: H07RN-F CHOOSE THE RIGHT SIZE CABLE The size of the power supply cable, signal cable, fuse and switch needed is determined by the maximum current in the unit. The maximum current is indicated on the rating plate located on the side panel of the unit. Refer to this rating plate to choose the right cable, fuse and switch. Minimum Cross Sectional Area of Power and Signal Cables Appliance Amps (A) AWG 10 18 13 16 18 14 25 12 30 10 Take Note of Fuse Specifications The air conditioner circuit board (PCB) is designed with a fuse to provide over current protection. The specifications of the fuse are printed on the circuit board, such as: T3.15A/250VAC, T5A/250VAC, etc. 1. Prepare the cable for connection: a. Using wire strippers, strip the rubber jacket from both ends of the signal cable to reveal about 40 mm (1.57 in) of the wires inside. b. Strip the insulation from the ends of the wires. c. Using wire crimper, crimp u-type lugs on the ends of the wires. 2. Open the front panel of the indoor unit. 3. Using a screwdriver, open the wire box cover on the right side of the unit. This will reveal the terminal block. Note: Pay attention to the live wire. While crimping wires, make sure to distinguish the Live (“L”) Wire and other wires. The wiring diagram is located on the inside of the wire cover on the indoor unit. 4. Unscrew the cable clamp below the terminal block and place it to the side. 5. Facing the back of the unit, remove the plastic panel on the bottom left-hand side. 6. Feed the signal wire through this slot, from the back of the unit to the front. 7. Facing the front of the unit, match the wire colours with the labels on the terminal block, connect the u-lug and firmly screw each wire to its corresponding terminal. 8. After checking to make sure every connection is secure, use the cable clamp to fasten the signal cable to the unit. Screw the cable clamp down tightly. 9. Replace the wire cover on the front of the unit and the plastic panel on the back. 14 INSTALLATION INSTRUCTIONS Step 7: Wrap piping and cables Before passing the piping, drain hose and the signal cable through the wall hole, bundle them together to save space, protect them and insulate them. 1. Bundle the drain hose, refrigerant pipes and signal cable. Note: Ensure that the drain hose is at the bottom of the bundle. Putting the drain hose at the top of the bundle can cause the drain pan to overflow, which can lead to fire or water damage. 2. Using adhesive vinyl tape, attach the drain hose to the underside of the refrigerant pipes. 3. Using insulation tape, wrap the signal wire, refrigerant pipes and drain hose tightly together. Note: While bundling these items together, do not intertwine or cross the signal cable with any other wiring. Note: When wrapping the bundle, keep the ends of piping unwrapped. Access is required to test for leaks at the end of the installation process. 15 INSTALLATION INSTRUCTIONS Step 8: Mount the Indoor Unit If new connective piping was installed to the outdoor unit, complete the following: 1. If the refrigerant piping has already been passed through the wall, proceed to step 4. 2. Otherwise, double check that the ends of the refrigerant pipes are sealed to prevent dirt or foreign materials from entering the pipes. 3. Slowly pass the wrapped bundle of refrigerant pipes, drain hose and signal wire through the hole in the wall. 4. Hook the top of the indoor unit on the upper hook of the mounting plate. 5. Check that the unit is hooked firmly on mounting by applying slight pressure to the left and right-hand sides of the unit. The unit should not jiggle or shift. 6. Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps onto the hooks along the bottom of the mounting plate. 7. Check that the unit is firmly mounted by applying slight pressure to the left and right-hand sides of the unit. If refrigerant piping is already embedded in the wall, complete the following: 1. Hook the top of the indoor unit on the upper hook of the mounting plate. 2. Use a bracket or wedge to prop up the unit, allowing enough room to connect the refrigerant piping, signal cable and drain hose. 3. Connect the drain hose and refrigerant piping. Refer to the Refrigerant Piping Connection section for more information. 4. Keep the pipe connection point exposed to perform the leak test. Refer to the Electrical Checks and Leak Checks section for more information. 5. After the leak test, wrap the connection point with insulation tape. 6. Remove the bracket or wedge that is propping up the unit. 7. Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps onto the hooks along the bottom of the mounting plate. Unit is Adjustable The hooks on the mounting plate are smaller than the holes on the back of the unit. The unit can be adjusted left or right by approximately 30 - 50 mm (1.25 - 1.95 in) depending on the model. 16 INSTALLATION INSTRUCTIONS OUTDOOR UNIT INSTALLATION Step 1: Select installation location Before installing the outdoor unit, choose an appropriate location for the unit. Proper installation locations meet the following requirements: • • • • • Good air circulation and ventilation. Firm and solid; the location can support the unit and will not vibrate. Noise from the unit will not be disturbing. The unit will be protected from prolonged periods of direct sunlight, rain or snow. The location must meet the special requirements outlined below: Do not install the unit in the following locations: • • • • • • Near obstacles that will block air inlets or outlets. Near a public street, crowded areas or where noise from the unit will disturb others. Near animals or plants that could be harmed by hot air discharge. Near any source of combustible gas. In a location that is exposed to large amounts of dust. In a location that is exposed to large amounts of salty air. Special Considerations For Extreme Weather If the unit is exposed to heavy wind, install the unit so that the air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier in front of the unit to protect it from the wind. If the unit is exposed to heavy rain or snow, build a shelter above the unit to protect it. Be careful not to obstruct air flow around the unit. If the unit is exposed to salty air, use an outdoor unit that is specially designed to resist corrosion. 17 INSTALLATION INSTRUCTIONS Step 2: Install the drain joint Before bolting the outdoor unit in place, install the drain joint at the bottom of the unit. There are two types of drain joint depending on the type of unit. 1. 2. 3. 4. Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit. Insert the drain joint into the hole in the base pan of the unit. Rotate the drain joint 90° until it clicks in place facing the front of the unit. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during heating mode. The base hole for the drain joint can be found on the bottom of the unit. Note For Cold Climates In cold climates, ensure that the drain hose is positioned as close to vertical as possible to encourage swift water drainage. If water drains too slowly it can freeze inside the drain hose and flood the unit. 18 INSTALLATION INSTRUCTIONS Step 3: Anchor the outdoor unit The outdoor unit can be anchored to the ground or to a wall-mounted bracket. The following is a list of outdoor unit sizes and the distance between their mounting feet. Prepare the installation base of the unit according to the dimensions and images below. Unit Mounting Dimensions Chart Model Number DAS180DBAHWDB Unit Dimensions (W x H x D) 922x715x379 (36.3”x28.2”x14.9”) Distance A (mm / in) 540 (21.26”) Distance B (mm / in) 350 (13.8”) WARNING When drilling into concrete, eye protection should be worn at all times. If the unit will be ground mounted, follow the below instructions: 1. 2. 3. 4. 5. 6. 7. 8. Mark the positions for four expansion bolts based on dimensions in the unit mounting dimensions chart. Pre-drill holes for expansion bolts. Clean concrete dust away from holes. Place a nut on the end of each expansion bolt. Hammer expansion bolts into the pre-drilled holes. Remove the nuts from the expansion bolts and place outdoor unit on the bolts. Put washer on each expansion bolt and then replace the nuts. Using a wrench, tighten each nut until snug. If the unit will be wall mounted, follow the below instructions: 1. 2. 3. 4. 5. Mark the positions of the bracket holes based on dimensions in the unit mounting dimensions chart. Pre-drill holes for expansion bolts. Clean concrete dust away from holes. Place a washer and a nut on the end of each expansion bolt. Thread the expansion bolts through the holes on the mounting brackets, put mounting brackets in position and hammer the expansion bolts into the wall. 6. Check that the mounting brackets are level. 7. Carefully lift the unit and place its mounting feet on the brackets. 8. Bolt the unit firmly to the brackets. Note: To reduce vibrations and noise of a wall-mounted unit, install the unit with rubber gaskets. 19 INSTALLATION INSTRUCTIONS Step 4: Connect the signal and power cables The outdoor unit’s terminal block is protected by an electrical wiring cover on the side of the unit. A comprehensive wiring diagram is printed on the inside of the wiring cover. Cable Types: • Indoor Power Cable (if applicable): H05V-F or H05V2-F • Outdoor Power Cable: H07RN-F • Signal Cable: H07RN-F WARNING All wiring must be performed in accordance with the wiring diagram located on the inside of the outdoor unit’s wire cover. Do not mix up live and null wires. This is dangerous and can cause the appliance to malfunction. Minimum Cross Sectional Area of Power and Signal Cables Appliance Amps (A) AWG 10 18 13 16 18 14 25 12 30 10 1. Prepare the cable for connection: a. Using wire strippers, strip the rubber jacket from both ends of the signal cable to reveal about 40 mm (1.57 in) of the wires inside. b. Strip the insulation from the ends of the wires. Note: Pay attention to the c. Using wire crimper, crimp u-type lugs on the ends of the wires. live wire. While crimping wires, make sure to 2. Unscrew the electrical wiring cover and remove it. distinguish the Live (“L”) Wire and other wires. 3. Unscrew the cable clamp below the terminal block and place it to the side. 4. Match the wire colours and labels with the labels on the terminal block and firmly screw the u-lug of each wire to its corresponding terminal. 5. After checking to make sure every connection is secure, loop the wires around to prevent rain water from flowing into the terminal. 6. Using the cable clamp, fasten the cable to the unit. Screw the cable clamp down tightly. 7. Insulate unused wires with PVC electrical tape. Arrange them so that they do not touch any electrical or metal parts. 8. Replace the wire cover on the side of the unit and screw it into place. The wiring diagram is located on the inside of the wire cover on the outdoor unit. 20 INSTALLATION INSTRUCTIONS REFRIGERANT PIPING CONNECTION The length of the refrigerant piping will affect the performance and energy efficiency of the unit. Nominal efficiency is tested on units with a pipe length of 5 m (16.5 ft). CONNECTION INSTRUCTIONS - REFRIGERANT PIPING Step 1: Cut pipes When preparing refrigerant pipes, take extra care to cut and flare them properly. This will ensure efficient operation and minimize the need for future maintenance. 1. Measure the distance between the indoor and outdoor units. 2. Using a pipe cutter, cut the pipe a little longer than the measured distance. 3. Make sure that the pipe is cut at a perfect 90°. Note: Do not damage, dent or deform the pipe while cutting. This will drastically reduce the heating efficiency of the unit. Step 2: Remove burrs Burrs can affect the air-tight seal of the refrigerant piping connection. Burrs must be completely removed. 1. Hold the pipe at a downward angle to prevent burrs from falling into the pipe. 2. Using a reamer or de-burring tool, remove all burrs from the cut section of the pipe. 21 INSTALLATION INSTRUCTIONS Step 3: Flare pipe ends Proper flaring is essential to achieve an airtight seal. 1. After removing burrs from the cut pipe, seal the ends with PVC tape to prevent foreign materials from entering the pipe. 2. Sheath the pipe with insulating material. 3. Place flare nuts on both ends of the pipe. Make sure they are facing in the right direction as they cannot be removed or adjusted after flaring. 4. Remove the PVC tape from the ends of the pipe when ready to perform flaring work. 5. Clamp flare form on the end of the pipe. The end of the pipe must extend beyond the edge of the flare form in accordance with the dimensions shown in the table and image below. PIPING EXTENSION BEYOND FLARE FORM Outer Pipe Diameter (mm) Dimension A Minimum (mm) Dimension A Maximum (mm) Ø 6.35 (Ø 0.25 in) 0.7 (0.0275 in) 1.3 (0.05 in) Ø 9.52 (Ø 0.375 in) 1.0 (0.04 in) 1.6 (0.063 in) Ø 12.7 (Ø 0.5 in) 1.0 (0.04 in) 1.8 (0.07 in) Ø 16 (Ø 0.63 in) 2.0 (0.078 in) 2.2 (0.086 in) 6. Place flaring tool onto the form. 7. Turn the handle of the flaring tool clockwise until the pipe is fully flared. 8. Remove the flaring tool and flare form and then inspect the end of the pipe for cracks and even flaring. 22 INSTALLATION INSTRUCTIONS Step 4: Connect pipes When connecting refrigerant pipes, be careful not to use excessive torque or to deform the piping in any way. Connect the low pressure pipe first and then connect the high pressure pipe. Note: When bending connective refrigerant piping, the minimum bending radius is 10 cm (3.9 in). CONNECTING PIPING TO INDOOR UNIT 1. Align the center of the two pipes that will be connected. 2. Tighten the flare nut as tightly as possible by hand. 3. Using a spanner, grip the nut on the unit tubing. 4. While firmly gripping the nut on the unit tubing, use a torque wrench to tighten the flare nut according to the torque values in the torque requirements table below. Loosen the flaring nut slightly, then tighten again. Excessive force can break the nut or damage the refrigerant piping. Do not exceed the torque requirements shown in the table below. Outer Diameter of Pipe (mm) Ø 6.35 (Ø 0.25 in) Ø 9.52 (Ø 0.375 in) Ø 12.7 (Ø 0.5 in) Ø 16 (Ø 0.63 in) TORQUE REQUIREMENTS Tightening Torque (N•cm) 1,500 (11 lb•ft) 2,500 (18.4 lb•ft) 3,500 (25.8 lb•ft) 4,500 (19 lb•ft) 23 Add. Tightening Torque (N•m) 1,600 (11.8 lb•ft) 2,600 (19.18 lb•ft) 3,600 (26.55 lb•ft) 4,700 (34.67 lb•ft) INSTALLATION INSTRUCTIONS CONNECTING PIPING TO OUTDOOR UNIT 1. Unscrew the cover from the packed valve on the side of the outdoor unit. 2. Remove protective caps from ends of valves. 3. Align flared pipe end with each valve and tighten the flare nut as tightly as possible by hand. 4. Using a spanner, grip the body of the valve. Do not grip the nut that seals the service valve. 5. While firmly gripping the body of the valve, use a torque wrench to tighten the flare nut according to the correct torque values. 6. Loosen the flaring nut slightly, then retighten again. 7. Repeat steps 3 to 6 for the remaining pipe. 24 INSTALLATION INSTRUCTIONS AIR EVACUATION Preparations and Precautions Air and foreign matter in the refrigerant circuit can cause abnormal rises in pressure, which can damage the air conditioner, reduce its efficiency and cause injury. Use a vacuum pump and manifold gauge to evacuate the refrigerant circuit, removing any non-condensible gas and moisture from the system. Evacuation should be performed upon initial installation and when the unit is relocated. Before performing the evacuation: • Check to make sure that both the high pressure and low pressure pipes between the indoor and outdoor units are installed correctly. • Check to make sure all wiring is connected properly. Evacuation Instructions Before using the manifold gauge and vacuum pump, read their operation manuals to ensure they are used correctly. 25 INSTALLATION INSTRUCTIONS Evacuation Instructions 1. Connect the charge hose of the manifold gauge to the service port on the outdoor unit’s low pressure valve. 2. Connect another charge hose from the manifold gauge to the vacuum pump. 3. Open the low pressure side of the manifold gauge. Keep the high pressure side closed. 4. Turn on the vacuum pump to evacuate the system. 5. Run the vacuum for at least 15 minutes or until the compound meter reads -76cmHG (-105 Pa). 6. Close the low pressure side of the manifold gauge and turn off the vacuum pump. 7. Wait for 5 minutes then check that there has been no change in the system pressure. 8. If there is a change in the system pressure, refer to the Gas Leak Check section for information on how to check the system for leaks. If there is no change in the system pressure, unscrew the cap from the packaged high pressure valve. 9. Insert hexagonal wrench into the packed high pressure valve and open the valve by turning the wrench in a 1/4 clockwise turn. Listen for gas to exit the system, then close the valve after 5 seconds. 10. Watch the pressure gauge for 1 minute to ensure there is no change in the pressure. The pressure gauge should read slightly higher than atmospheric pressure. 11. Remove the charge hose from the service port. 12. Using a hexagonal wrench, fully open both the high pressure and low pressure valves. 13. Tighten valve caps on all three valves, (service port, high pressure and low pressure) by hand. Tighten further with a torque wrench if necessary. WARNING DO NOT MIX REFRIGERANT TYPES 26 INSTALLATION INSTRUCTIONS Note: Open valve stems gently. When opening valve stems, turn the hexagonal wrench until it hits against the stopper. Do not try to force the valve to open further. Note: Some systems require additional charging depending on pipe lengths. The standard pipe length varies according to local regulations. For example, in North America, the standard pipe length is 7.5 m (25 feet). In other areas, the standard pipe length is 5 m (16 feet). The additional refrigerant to be charged can be calculated using the formula in the below chart. Additional Refrigerant Per Pipe Length Connective Pipe Length (m) < Standard Pipe Length > Standard Pipe Length Air Purging Method Additional Refrigerant Vacuum Pump N/A Vacuum Pump Liquid Side: Ø 6.35 (ø 0.25 in) Liquid Side: Ø 9.52 (ø 0.375 in) Inverter R410a: (Pipe Length - SPL) x 15g/m (Pipe Length - SPL) x 0.16oZ/ft Inverter R410a: (Pipe Length - SPL) x 30g/m (Pipe Length - SPL) x 0.32oZ/ft SPL = Standard Pipe Length 27 INSTALLATION INSTRUCTIONS ELECTRICAL AND GAS LEAK CHECKS Electrical Safety Checks After installation, confirm that all electrical wiring is installed in accordance with local and national regulations and according to the installation manual. Check Grounding Work Before completing a test run, measure grounding resistance by visual detection and with grounding resistance tester. Grounding resistance must be less than 4. Check for Electrical Leakage During the test run, use an electroprobe and multimeter to perform a comprehensive electrical leakage test. If electrical leakage is detected, turn off the unit immediately and call a licensed electrician to find and resolve the cause of the leakage. WARNING ALL WIRING MUST COMPLY WITH LOCAL AND NATIONAL ELECTRICAL CODES AND MUST BE INSTALLED BY A LICENSED ELECTRICIAN. Gas Leak Checks There are two acceptable methods of checking for gas leaks. Soap and Water Method Using a soft brush, apply soapy water or liquid detergent to all pipe connection points on the indoor and outdoor units. The presence of bubbles indicates a leak. Leak Detector Method If using a leak detector, refer to the device’s operation manual for proper usage instructions. Note: After completing gas leak checks, confirm that all piping connection points do not leak and make sure to replace the valve cover on the outdoor unit. 28 INSTALLATION INSTRUCTIONS TEST RUN Before completing a test run, make sure to complete all electrical safety checks and gas leak checks. Confirm that the unit’s electrical system is safe and operating properly. Check all flare nut connections and confirm that the system is not leaking. Test Run Instructions 1. Connect power to the unit. 2. Press the ON/OFF button on the remote to turn the unit on. 3. Press the MODE button to scroll through the following functions: • COOL - select lowest possible temperature • HEAT - select highest possible temperature 4. Allow each function to run for 5 minutes and perform the following checks: • • • • • • • • • • • No electrical leakage Unit is properly grounded All electrical terminals are properly covered Indoor and outdoor units are solidly installed All pipe connection points do not leak Water drains properly from the drain hose All piping is properly insulated Unit performs COOL function properly Unit performs HEAT function properly Indoor unit louvers rotate properly Indoor unit responds to the remote control IMPORTANT: During operation, the pressure of the refrigerant circuit will increase. This may reveal leaks that were not present during the initial leak check. Take time during the test run to double check that all refrigerant pipe connection points do not have leaks. 5. After the test run is successfully complete, use the remote control to return the unit to normal operating temperature. Using insulation tape, wrap the indoor refrigerant pipe connections that were left uncovered during the indoor unit installation process. Test Run in Low Temperature If the ambient temperature is below 17oC (62.6 F), the COOL function will not run when using the remote control. In this instance, use the manual control button to test the COOL function. 1. Lift the front panel of the indoor unit and raise it until it clicks into place. 2. The manual control button is located on the right-hand side of the unit. Press it two times to select the COOL function. 3. Perform test run as normal. Disposal Guidelines This appliance contains refrigerant and other potentially hazardous materials. When disposing of this appliance, the law requires special collection and treatment. Do not dispose of this appliance as household waste or unsorted municipal waste. 29 LIMITED IN-HOME APPLIANCE WARRANTY This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating LIMITED APPLIANCE WARRANTY conditions intended by the manufacturer. Thisquality warranty isproduct available only to the person toto whom unitfrom was originally sold by Danby Products (Canada) orand Danbyworkmanship, Products Inc.provided (U.S.A.) (hereafter This is warranted be the free manufacturer’s defectsLimited in material that the “Danby”) or by an authorized distributor of Danby, and is non-transferable. unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter “Danby”)TERMS or by authorized distributor of Danby, and is non-transferable. OF an WARRANTY Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided. TERMS OF WARRANTY Plastic parts, are warranted for thirty (30) days only from no extensions provided. First Year During the first twelve (12) months, any functional partspurchase of this productdate, found towith be defective, will be repaired or replaced, at warrantor’s option, at no charge to the ORIGINAL purchaser. First 24 months During the first twenty-four (24) months, any functional parts of this product found to be defective, willreserves be replaced, at warrantor’s no charge to the purchaser. To obtain Danby the right to limit the boundaries ofoption, “In Home at Service” to the proximity of anORIGINAL Authorized Service Depot. Any app liance Service requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at their own expense) the original retailer (point will of purchase) or a service depot repair.for See “Boundaries of In Home ice”food below. or Nothing within this warranty shalltoimply that Danby be responsible or for liable any spoilage or Serv damage to Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service other contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper. must be performed by a qualified service technician. If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all EXCLUSIONS obligations of Danby under this warranty shall be void. Save as herein provided, by Danby, there are no other warranties, conditions, representations or guarantees, express or implied, made or intended by Danby or its authorized distributors and all other warranties, conditions, representaBoundaries of If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be tions or Service guarantees,delivered including conditions, guarantees underqualified any Sale of Goods Act In Home to theany nearestwarranties, authorized Danby Service Depot,representations as service must only beorperformed by a technician and certif ied for or like legislation orwarranty statuteservice is hereby excluded. Save as service herein provided, Danby not be by Danby.expressly Transportation charges to and from the location are not protected by shall this warranty and responsible are t he for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising responsibility of the purchaser. from the malfunction of the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless from any forbedamages persons or property Nothing within thisDanby warranty shall imply thatclaim Danby will responsible ortoliable for any spoilage or damagecaused to food orby otherthe c unit. ontents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper. GENERAL PROVISIONS No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the EXCLUSIONS following: Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages 1)under Power failure. to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of 2) Damage in transit or when moving the appliance. the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit. 3) Improper power supply such as low voltage, defective house wiring or inadequate fuses. 4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal GENERAL PROVISIONS operating conditions (extremely high or low room temperature). No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following: 5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence). 1) Power failure. 6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc. 7) Service callsinresulting in moving customer education. 2) Damage transit or when the appliance. 8) Improper Installation a free standing appliance 3) Improper power supply(ie. suchBuilding-in as low voltage, of defective house wiring or inadequate fuses.or using an appliance outdoors that is not approved for outdoor 4) Accident, alteration,application). abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions (extremely high or low room temperature). Proof 5)of purchase dateorwill be required claims; retain bills of sale. Use for commercial industrial purposes (ie. for If thewarranty appliance is not installedplease in a domestic residence). 6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc. 7) Service calls resulting in customer education. 8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application). Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our AUTHORIZED SERVICE DEPOT. Warranty Service In-home Danby Products Limited Danby Products Limited PO 1778, Guelph, N1H 6Z9 POBox Box 1778, Guelph, Ontario, Ontario, Canada N1HCanada 6Z9 Telephone: (519) 837-0920 Telephone: (519) 837-0920 FAX: (519) FAX: 837-0449(519) 837-0449 1-800-263-2629 1-800-263-2629 12/19 04/09 Danby Products Danby Products Inc. Inc. PO BoxPO669, Findlay, Ohio, U.S.A. Box 669, Findlay, Ohio, U.S.A. 45840 45840 Telephone:Telephone: (419) 425-8627 (419) 425-8629 (419) 425-8627 FAX: FAX: (419) 425-8629 Consignes de sécurité importantes LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ • Tout le câblage doit être organisé de manière PRÉCAUTIONS DE SÉCURITÉ Une mauvaise installation liée à l’omission d’instructions peut entraîner de graves dommages ou blessures. • Lorsque vous raccordez la tuyauterie de réfrigérant, ne laissez pas de substances ou de gaz autres que le réfrigérant spécifié pénétrer l’unité. La présence d’autres gaz ou substances réduira la capacité de l’unité et pourra entraîner une pression anormalement élevée au cours du cycle de réfrigération. Cela peut provoquer une explosion et vous blesser. • L’installation doit être effectuée par un distributeur ou spécialiste agréé. Une installation défectueuse peut entraîner des fuites d’eau, des décharges électriques ou un incendie. • En Amérique du Nord, l’installation doit être effectuée conformément aux exigences de la NEC et de la CEC uniquement par le personnel autorisé. • Contactez un technicien d’entretien agréé pour réparer ou effectuer des opérations de maintenance sur cette appareil. • N’utilisez que les pièces, pièces spécifiées et accessoires inclus pour l’installation. L’utilisation de pièces non standard peut entraîner des fuites d’eau, des décharges électriques, un incendie et une défaillance de l’unité. • Installez l’unité à un emplacement stable et solide, capable de supporter son poids. Si l’endroit choisi ne peut pas supporter le poids de l’unité, ou si l’installation n’est pas correctement effectuée, il est possible que l’unité tombe, ce qui pourrait entraîner de graves blessures et dommages. • Pour tous les travaux électriques, respectez toutes les normes et réglementations locales et nationales concernant le câblage, ainsi que le manuel d’installation. Pour l’alimentation, vous devez utiliser un circuit indépendant et une seule prise. Ne branchez pas d’autres appareils sur cette prise. Les capacités électriques insuffisantes ou les défauts des travaux électriques peuvent entraîner des décharges électriques ou incendies. • Utilisez les câbles spécifiés pour tous les travaux électriques. Raccordez et serrez fermement les câbles pour éviter que des forces extérieures n’endommagent la borne. Les mauvais raccordements électriques peuvent entraîner une surchauffe et un incendie, mais aussi des décharges électriques. • • • • • • appropriée pour garantir que le couvercle du tableau de contrôle puisse se refermer correctement. Si le couvercle du tableau de contrôle n’est pas correctement refermé, cela peut favoriser la corrosion, qui à son tour pourrait chauffer les points de raccordement de la borne, déclencher un incendie ou entraîner des décharges électriques. In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed air conditioning units is highly recommended. Cet appareil n’est pas destiné à être utilisé par des personnes (y compris des enfants) dont les capacités physiques, sensorielles ou métalliques peuvent être différentes ou réduites, ou qui ont de l’expérience ou des connaissances, à moins que ces personnes ne reçoivent de supervision ou de formation pour faire fonctionner l’appareil par une personne responsable de leur sécurité. N’installez pas l’unité dans un lieu susceptible d’être exposé à des fuites de gaz combustible. Si du gaz combustible s’accumule autour de l’unité, cela peut déclencher un incendie. N’utilisez pas cet appareil dans une pièce humide, comme une salle de bain ou une buanderie. Une trop grande exposition à l’eau peut provoquer un court-circuit des composants électriques. L’appareil doit être correctement mis à la terre ou des chocs électriques peuvent survenir. Installez la tuyauterie de drainage conformément aux instructions de ce manuel. Un mauvais drainage peut causer des dégâts d’eau. REMARQUE CONCERNANT LES GAZ FLUORÉS • Ce climatiseur est un appareil hermétiquement scellé et contient des gaz fluorés. Pour obtenir des informations spécifiques sur le type et la quantité de gaz, veuillez vous reporter à l’étiquette concernée apposée sur l’appareil en elle-même. • L’installation, le service, l’entretien et la réparation de cet appareil doivent être effectués par un technicien qualifié. • La désinstallation et le recyclage de l’appareil doivent être effectués par un technicien qualifié. • Si l’appareil dispose d’un système de détection des fuites, l’absence de fuites doit être vérifiée au moins tous les 12 mois. Lors de la vérification des fuites, un relevé approprié de tous les contrôles est fortement recommandé. GARDER CES INSTRUCTIONS! 31 INSTRUCTIONS D’INSTALLATION ACCESSOIRES Le système de climatisation comprend les accessoires suivants. Utilisez toutes les pièces d’installation et les accessoires pour installer le climatiseur. Une mauvaise installation peut provoquer des fuites d’eau, des chocs électriques, des incendies ou provoquer l’échec de l’équipement. Dénomination Description Quantité Plaque de montage 2 Vis de fixation de la plaque de montage ST3.9 X 25 10 Agrafe d’ancrage 10 Télécommande 2 Batterie sèche AAA.LR03 4 Joint d’étanchéité 2 Raccord d’évacuation 2 32 INSTRUCTIONS D’INSTALLATION RÉSUMÉ DE L’INSTALLATION Plaque de montage mural Panneau avant Câble d’alimentation Aérateur Conduite de drainage Filtre fonctionnel à l’avant du filtre principal Câble de signal Conduite de réfrigérant Télécommande Câble d’alimentation de l’appareil extérieure Remarque: Les illustrations de ce manuel ne sont fournies qu’à des fins explicatives. Il est possible que la forme de votre unité intérieure soit légèrement différente. La véritable forme de l’unité doit prévaloir. Remarque: Le modèle DAS180DBAHWDB peut être connecté à plusieurs unités intérieures. Voir la page suivante pour plus de détails. 33 INSTRUCTIONS D’INSTALLATION RÉSUMÉ DE L’INSTALLATION Lors de l’installation de plusieurs unités intérieures sur une seule unité extérieure, assurez-vous que la longueur du tuyau de réfrigérant et la hauteur de chute entre les unités intérieure et extérieure répondent aux exigences suivantes: Unité extérieure Unité intérieure Unité extérieure 49ft (15m) 32.8ft (10m) 49ft (15m) Unité extérieure Unités intérieures pouvant être utilisées en combinaison Fréquence d'arrêt / de démarrage du compresseur Tension de la source d'alimentation Nombre d'unités connectées 1 à 5 unités Temps d'arrêt 3 minutes ou plus Fluctuation de tension Chute de tension au démarrage Déséquilibre d'intervalle à ± 10% de la tension nominale à ± 15% de la tension nominale Les unités sont en mètres / pieds Max. longueur pour toutes les pièces Max. longueur pour une unité intérieure Max. différence de hauteur entre intérieur et extérieur Max. différence de hauteur entre les unités intérieures 34 1 unité 2 40/131 25/82 15/49 10/33 à ± 3% de la tension nominale 1 unité 3 60/197 30/98 15/49 10/33 1 unité 4 80/262 35/115 15/49 10/33 1 unité 5 80/262 35/115 15/49 10/33 INSTRUCTIONS D’INSTALLATION RÉSUMÉ DE L’INSTALLATION - UNITÉ INTÉRIEURE 35 INSTRUCTIONS D’INSTALLATION RÉSUMÉ DE L’INSTALLATION - UNITÉ INTÉRIEURE 36 INSTRUCTIONS D’INSTALLATION INSTALLATION DE L’APPREIL INTÉRIEURE Avant d’installer l’appareil intérieure, reportez-vous à l’étiquette figurant sur la boîte du produit pour vous assurer que le numéro de modèle de l’appareil intérieure correspond à celui de l’appareil extérieure. Le numéro de modèle de l’appareil intérieur se terminera par un “-I” et le numéro de modèle de l’appareil extérieur se terminera par un “-O”, sinon ils devraient être identiques. Étape 1 : choix du lieu d’installation Voici les normes qui vous aideront à choisir le lieu approprié à l’appareil. • • • • • • Bonne circulation d’air. Évacuation pratique. Le bruit de l’unité ne dérangera pas d’autres personnes. Stable et solide; l’emplacement d’installation ne vibrera pas. Solidité suffisante pour supporter le poids de l’appareil. À au moins 1 m (3 pieds) de tous les autres appareils électriques, comme les téléviseurs, les radios et les ordinateurs, qui pourraient avoir un impact sur le signal à distance infrarouge. N’installez PAS l’appareil dans les lieux suivants: • • • • • À proximité d’une source de chaleur, de vapeur ou de gaz combustible. À proximité d’éléments inflammables, par exemple, des rideaux ou du linge. À proximité d’un obstacle susceptible de bloquer la circulation d’air. À proximité d’une porte d’entrée. Dans un lieu directement exposé à la lumière du soleil. Reportez-vous au schéma suivant pour vous assurer que la distance séparant l’appareil des murs et du plafond est appropriée: 37 INSTRUCTIONS D’INSTALLATION Étape 2 : installation de la plaque de fixation sur le mur La plaque de fixation est la pièce sur laquelle vous installerez l’appareil intérieure. 1. Retirez la vis fixant la plaque de fixation à l’arrière de l’appareil intérieure. 2. Placez la plaque de montage contre le mur dans l’endroit où l’appareil intérieur sera installé. 3. Percez les trous pour les vis de montage, en veillant à ce que les vis pénètrent dans les goujons de mur qui peuvent supporter le poids de l’appareil. 4. Vissez la plaque de fixation au mur avec les vis fournies. Assurez-vous que la plaque de fixation est bien à plat contre le mur. Remarque: Si le mur est en brique, en béton ou autre matériau similaire, percez des trous de 5 mm de diamètre (0,2 pouce) dans le mur et insérez-y les douilles d’ancrage fournies. Fixez ensuite la plaque au mur en serrant les vis directement sur les douilles. Dimensions de la plaque de fixation Différentes plaques de fixation correspondent aux différents modèles. Pour vous assurer que vous disposez de suffisamment d’espace pour installer l’unité intérieure, vérifiez les diagrammes ci-dessous qui montrent les deux types de plaques de montage ainsi que les dimensions suivantes: • • • • • Largeur de plaque de fixation. Hauteur de plaque de fixation. Largeur de l’appareil intérieure par rapport à la plaque. Hauteur de l’appareil intérieure par rapport à la plaque. Emplacement recommandé pour le trou dans le mur, que ce soit du côté gauche ou droit de la plaque de fixation. • Distances relatives entre les trous de vis. 3.7 cm (1.45”) Contour de l'unité intérieure Trou de paroi arrière gauche 6.5 cm (2.5”) Trou de paroi arrière droite 6.5 cm (2.5”) 38 12.6 cm (4.96”) 80.2 cm (31.6”) 4.2 cm (1.65”) 22.9 cm (9.01”) 22.8 cm (8.98”) 5.8 cm (2.28”) 72.2 cm (28.45”) 40.1 cm (15.78”) 4.7 cm (1.85”) 29 cm (11.4”) 4.9 cm (1.95”) 13.6 cm (5.35”) 4.9 cm (1.95”) 17.9 cm (7.05”) 10.1 cm (4”) Trou de paroi arrière gauche 6.5 cm (2.5”) Modèle B 34.8 cm (13.7”) 29.7 cm (11.7”) Modèle A Contour de l'unité intérieure Trou de paroi arrière droite 6.5 cm (2.5”) INSTRUCTIONS D’INSTALLATION Étape 3 : perçage d’un trou dans le mur pour la tuyauterie de raccordement Vous devez percer un trou dans le mur pour la tuyauterie de réfrigérant, la conduite d’évacuation, et le câble de signal qui raccorderont l’appareil intérieure et l’appareil extérieure. 1. Déterminez l’emplacement du trou dans le mur en fonction de l’emplacement de la plaque de fixation. Voir l’étape 2 pour le montage des dimensions de la plaque. 2. À l’aide d’un foret aléseur de 65 mm (2,5 pouces), percez un trou dans le mur. Assurez-vous de percer le trou en respectant un angle légèrement descendant, de manière à ce que l’extrémité extérieure du tuyau se. 3. Placez le manchon de protection dans le trou. Ce dernier protège les bords du trou et contribuera à l’étanchéité une fois que vous aurez terminé le processus d’installation. Remarque: Pendant le perçage du trou dans le mur, veillez à éviter les fils, la plomberie et tout autre élément sensible. 39 INSTRUCTIONS D’INSTALLATION Étape 4 : préparation de la tuyauterie de réfrigérant La tuyauterie se situe dans une gaine isolante fixée à l’arrière de l’unité. Vous devez préparer la tuyauterie avant de la faire passer par le trou du mur. Reportezvous à la section Raccordement de la tuyauterie de réfrigérant de ce manuel pour obtenir des instructions détaillées sur les exigences d’évasement de conduite et de couple de serrage pour l’évasement, sur la technique à employer, etc. 1. En vous basant sur la position du trou du mur par rapport à la plaque de fixation, choisissez le côté par lequel la tuyauterie sortira de l’unité. Panneau de montage 2. Si le trou du mur se trouve derrière l’appareil, laissez le panneau amovible en place. Si le trou se trouve au niveau de l’un des côtés de l’appareil intérieure, retirez le panneau amovible de plastique de ce côté de l’appareil. De cette manière, une fente par laquelle votre tuyauterie pourra sortir de l’unité apparaîtra. Utilisez une pince à bec effilé si le panneau de plastique est trop difficile à retirer à la main. 3. Utilisez des ciseaux pour découper la longueur de gaine isolante pour faire apparaître environ 15 cm (6 pouces) de tuyauterie de réfrigérant. Cette opération a deux objectifs: • faciliter le processus de raccordement de la tuyauterie de réfrigérant • Faciliter les vérifications à la recherche de fuite de gaz et vous permettre de rechercher les bosses 4. Si la tuyauterie de connexion existante est déjà intégrée dans le mur, passez directement à l’étape 5: Connectez le tuyau de vidange. S’il n’y a pas de tuyauterie intégrée, connectez la tuyauterie de réfrigérant de l’appareil intérieure à la tuyauterie de connexion qui rejoindra les appareils intérieures et extérieures. 5. En vous basant sur la position du trou du mur par rapport à la plaque de fixation, déterminez l’angle nécessaire à votre tuyauterie. Emparez-vous de la tuyauterie de réfrigérant par la base du coude. 6. Coudez la tuyauterie vers le trou en appliquant lentement une pression régulière. Ne bosselez pas et n’endommagez pas la tuyauterie au cours de ce processus. Remarque concernent l’angle de la tuyaterie La tuyauterie de réfrigérant peut sortir de l’appareil intérieure sous quatre angles différents: • • • • partie gauche arrière gauche partie droite arrière droite PRÉCAUTION Soyez extrêmement prudent : ne bosselez pas et n’endommagez pas la conduite en la coudant vers l’extérieur de l’unité. Toutes les bosses de la conduite affecteront le fonctionnement de l’appareil. 40 INSTRUCTIONS D’INSTALLATION Étape 5 : raccordement du tuyau d’évacuation Par défaut, le tuyau d’évacuation se raccorde au côté gauche de l’appareil, lorsque vous faites faces à l’arrière de l’appareil). Il peut cependant être raccordé au côté droit. 1. Pour garantir une bonne évacuation, raccordez le tuyau d’évacuation au côté par lequel votre conduite de réfrigérant sort de l’appareil. 2. Fixez le raccord de tuyau d’évacuation (acheté séparément) à l’extrémité du tuyau d’évacuation. 3. Enroulez fermement un ruban de téflon autour du point de raccordement pour garantir une bonne étanchéité et empêcher les fuites. 4. Pour ce qui est de la portion de tuyau d’évacuation qui restera à l’intérieur du bâtiment, enveloppez-la d’une pousse isolante pour conduites afin d’empêcher la condensation. 5. Retirez le filtre à air et versez une petite quantité d’eau dans l’entonnoir d’évacuation pour vous assurer que l’eau s’écoule régulièrement hors de l’unité. Remarque concernent le tuyau d’évacuation • N’entortillez PAS le tuyau d’évacuation. • Ne créez pas de piège à eau. • Ne placez pas l’extrémité du tuyau d’évacuation dans de l’eau ou dans un récipient qui recueillerait l’eau. Remarque: Pour éviter les fuites indésirables, vous devez reboucher le trou d’évacuation inutilisé avec le bouchon de caoutchouc fourni. Voir ci-dessous des exemples d’installation correcte du tuyau de vidange: 41 INSTRUCTIONS D’INSTALLATION LISEZ CES RÉGLEMENTATIONS AVANT D’EFFECTUER TOUT TRAVAIL ÉLECTRIQUE 1. Tout le câblage doit être conforme aux codes électriques locaux et nationaux ; il doit en outre être installé par un électricien habilité. 2. Tous les raccordements électriques doivent être effectués conformément au Schéma de raccordement électrique figurant sur les panneaux de l’unité intérieure et de l’unité extérieure. 3. Si vous rencontrez un grave problème de sécurité avec l’alimentation, arrêtez immédiatement de travailler. Expliquez votre raisonnement au client, et refusez d’installer l’unité tant que le problème de sécurité n’est pas correctement résolu. 4. La tension d’alimentation devrait représenter 90 à 100 % de la tension nominale. Une alimentation insuffisante peut entraîner des dysfonctionnements, des décharges électriques ou un incendie. 5. Si vous raccordez l’alimentation à un câblage fixe, installez une protection contre les surtensions et un interrupteur d’alimentation principal d’une capacité 1,5 fois supérieure à l’intensité maximale de l’unité. 6. Si vous raccordez l’alimentation à un câblage fixe, un interrupteur ou un disjoncteur déconnectant tous les pôles doit être intégré au câblage fixe. Ce dispositif doit être séparé des contacts d’au moins 3 mm (1/8 pouce). Le technicien qualifié doit utiliser un interrupteur ou disjoncteur approuvé. 7. Ne raccordez l’unité qu’à une prise du circuit de dérivation individuel. Ne branchez pas d’autres appareils sur cette prise. 8. Assurez-vous d’avoir correctement relié le climatiseur à la terre. 9. Tous les câbles doivent être fermement raccordés. Les câbles lâches peuvent entraîner une surchauffe de la borne, ce qui peut à son tour entraîner dysfonctionnement du produit et un éventuel incendie. 10. Ne laissez pas les câbles toucher ou reposer sur la tubulure de réfrigérant, le compresseur ou toute autre pièce mobile de l’unité. AVERTISSEMENT AVANT D’EFFECTUER TOUTE INTERVENTION ÉLECTRIQUE OU DE CÂBLAGE, COUPEZ L’ALIMENTATION PRINCIPALE DU SYSTÈME. AVERTISSEMENT Tout le câblage doit être effectué conformément au schéma de câblage situé à l’intérieur du couvercle du fil de l’appareil intérieur. Ne mélangez pas les fils en direct et nuls. Ceci est dangereux et peut provoquer un dysfonctionnement de l’appareil. 42 INSTRUCTIONS D’INSTALLATION Connectez le câblage aux bornes comme indiqué avec leurs numéros correspondants respectifs sur le bornier des unités intérieure et extérieure. Par exemple, consultez les modèles Américains suivants: La borne L1 (A) de l’unité extérieure doit être connectée à la borne L1 de l’unité intérieure. Faites passer le cordon d’alimentation principal dans la prise de ligne inférieure du serre-câble. Un-deux modèles: Modèle A Modèle E Modèle B Modèle C Modèle F 43 Modèle G Modèle D INSTRUCTIONS D’INSTALLATION Étape 6 : connexion du câble de signal Le câble de signal permet la communication entre l’appareil intérieure et l’unité extérieure. Vous devez d’abord choisir la taille de câble appropriée avant de le préparer pour le raccordement. Types de câble: • Câble d’alimentation intérieur (le cas échéant) : H05VV-F or H05V2V2-F • Câble d’alimentation extérieur : H07RN-F • Câble de signal : H07RN-F Superficie minimale de section entre le câble d’alimentation et le câble de signal CHOIX DE LA BONNE TAILLE DE CÂBLE Intensité nominale de l’appareil (A) AWG La taille nécessaire pour le câble d’alimentation, le câble 10 18 de signal, le fusible et l’interrupteur se détermine en fonction de l’intensité maximale de l’unité. L’intensité maximale est 13 16 indiquée sur la plaque d’identification située sur le panneau 18 14 latéral de l’unité. Reportez-vous à cette plaque pour choisir le bon câble, le bon fusible ou le bon interrupteur. 25 12 30 10 Noter les caractéristiques du fusible Le circuit imprimé du climatiseur (PCB) est muni d’un fusible offrant une protection contre les surintensités. Les caractéristiques de ce fusible sont imprimées sur le circuit, par exemple: T3.15A/250VAC, T5A/250VAC, etc. 1. Préparation du câble pour le raccordement: a. À l’aide d’un outil à dénuder, retirez la garniture de caoutchouc des deux extrémités du câble de signal pour faire apparaître environ 15 cm (6 pouces) des fils qu’elle renferme. b. Dénudez l’isolation des extrémités des fils. c. À l’aide d’une pince à sertir, sertissez des cosses en U aux extrémités des fils. 2. Ouvrez le panneau avant de l’unité intérieure. 3. À l’aide d’un tournevis, ouvrez le couvercle du boîtier de câblage situé du côté droit de l’unité. Vous ferez ainsi apparaître le bornier. Remarque: Lorsque vous sertissez les fils, assurezvous de bien distinguer le fil sous tension (« L ») des autres fils. Schéma de câblage qui se trouve dans le boîtier de câblage de l’appareil intérieure. 4. Dévissez le serre-câble qui se trouve sous le bornier et placez-le sur le côté. 5. En faisant face à l’arrière de l’unité, retirez le panneau de plastique qui se situe en bas à gauche. 6. Faites passer le câble de signal par cette fente, de l’arrière de l’unité jusqu’à l’avant. 7. En faisant face à l’avant de l’unité, associez les fils en vous fiant aux étiquettes du bornier, connectez la cosse en U, puis vissez chacun des fils sur la borne qui lui correspond. 8. Après avoir vérifié que tous les raccordements sont bien en place, utilisez le serre-câble pour fixer le câble de signal à l’unité. Vissez fermement le serre-câble. 9. Remettez le cache-fils en place à l’avant de l’unité et le panneau de plastique à l’arrière. 44 INSTRUCTIONS D’INSTALLATION Étape 7: enveloppement de la tuyauterie et du câble Avant de faire passer la tuyauterie de réfrigérant, le tuyau d’évacuation et le câble de signal par le trou du mur, vous devez les réunir pour gagner de la place, les protéger et les isoler. 1. Réunissez le tuyau d’évacuation, les conduites de réfrigérant et le câble de signal. Remarque: Assurez-vous que le tuyau d’évacuation se trouve tout en dessous du lot constitué. Placer le tuyau d’évacuation sur le dessus de ce lot pourrait entraîner un débordement de l’entonnoir d’évacuation, qui à son tour entraînerait un incendie ou des dégâts des eaux. 2. À l’aide d’un ruban de vinyle adhésif, fixez le tuyau au dessous des conduites de réfrigérant. 3. À l’aide d’un ruban isolant, enveloppez fermement ensemble le câble de signal, les conduites de réfrigérant et le tuyau d’évacuation. Remarque: Lorsque vous réunissez ces éléments ensemble, ne les entremêlez pas et n’entrecroisez pas le câble de signal avec d’autres câbles. Remarque: Lorsque vous enveloppez le lot constitué, n’enveloppez pas les extrémités de la tuyauterie. Vous devez pouvez y accéder pour vérifier qu’il n’y a pas de fuites à la fin du processus d’installation. 45 INSTRUCTIONS D’INSTALLATION Étape 8 : mise en place de l’unité intérieure Si vous avez installé une nouvelle tuyauterie de raccordement à l’unité extérieure, procédez comme suit: 1. Si vous aviez déjà fait passer une conduite de réfrigérant par le trou du mur, passez à l’étape 4. 2. Sinon, revérifiez que les extrémités des conduites de réfrigérant sont scellées pour éviter que de la saleté ou des matériaux étrangers ne pénètrent les conduites. 3. Faites doucement passer le lot enveloppé constitué des conduites de réfrigérant, du tuyau d’évacuation et du câble de signal par le trou du mur. 4. Accrochez le haut de l’appareil intérieure au crochet supérieur de la plaque de fixation. 5. Vérifiez que l’appareil est fermement accrochée à la plaque de fixation en appliquant une légère pression sur les côtés gauche et droit de l’appareil. L’appareil ne devrait pas remuer ou se déplacer. 6. En appliquant une pression régulière vers le bas, appuyez sur la moitié inférieure de l’appareil. Continuez à appuyer jusqu’à ce que l’appareil s’insère sur les crochets qui se situent le long du bas de la plaque de fixation. 7. Vérifiez à nouveau que l’appareil est fermement fixée en appliquant une légère pression sur les côtés gauche et droit de l’appareil. Si la tuyauterie de réfrigérant est déjà intégrée au mur, procédez comme suit: 1. Accrochez le haut de l’appareil intérieure au crochet supérieur de la plaque de fixation. 2. Utilisez un support ou une cale pour caler l’appareil, en vous conservant suffisamment d’espace pour raccorder la tuyauterie de réfrigérant, le câble de signal et le tuyau d’évacuation. 3. Raccordez le tuyau d’évacuation et la tuyauterie de réfrigérant. Reportez-vous à la section Raccordement de la tuyauterie de réfrigérant de ce manuel pour obtenir des instructions. 4. Laissez le point de raccordement de la tuyauterie exposer pour pouvoir procéder au test anti-fuites. Reportez-vous à la section Vérifications électriques et recherches de fuites de ce manuel. 5. Une fois le test anti-fuites effectué, enveloppez le point de raccordement d’un ruban isolant. 6. Retirez le support ou la cale qui calait l’appareil. 7. En appliquant une pression régulière vers le bas, appuyez sur la moitié inférieure de l’unité. Continuez à appuyer jusqu’à ce que l’unité s’insère sur les crochets qui se situent le long du bas de la plaque de fixation. L’emplacement de l’appareil est ajustable Les crochets de la plaque de montage sont plus petits que les trous situés à l’arrière de l’appareil. L’appareil peut être réglé à gauche ou à droite d’environ 30 à 50 mm (1,25 - 1,95 po) selon le modèle. 46 INSTRUCTIONS D’INSTALLATION INSTALLATION DE L’APPAREIL EXTÉRIEURE Étape 1 : choix du lieu d’installation Avant d’installer l’unité extérieure, vous devez choisir un lieu approprié. Les lieux d’installation appropriés respectent les normes suivantes: • • • • • Ils offrent une circulation d’air adéquate et une bonne ventilation. Ils sont stables et solides : le lieu d’installation peut supporter le poids de l’unité et ne vibrera pa. Le bruit de l’appareil ne dérangera pas. Ces lieux sont protégés contre les longues périodes d’exposition directe au soleil ou aux précipitations. L’emplacement doit répondre aux exigences spatiales décrites ci-dessous: N’installez pas l’appareil aux endroits suivants: • à proximité d’un obstacle qui obstruera les entrées et sorties d’air. • à proximité d’une rue publique, de zones bondées ou de zones où le bruit de l’appareil dérangera d’autres personnes. • à proximité d’animaux ou de végétaux pour lesquels l’évacuation d’air chaud serait néfaste. • à proximité d’une source de gaz combustible. • dans un lieu exposé à une grande quantité de poussière. • dans un lieu exposé à une quantité excessive d’air salin. Considérations particulières concernant les conditions climatiques extrêmes Si l’appareil est exposé à un vent fort, installez l’appareil afin que le ventilateur de sortie d’air soit à un angle de 90 ° par rapport à la direction du vent. Si nécessaire, construisez une barrière devant l’appareil pour la protéger contre le vent. Si l’appareil est exposé à de fortes pluies ou à de la neige, construisez un abri au-dessus de l’appareil pour le protéger. Veillez à ne pas obstruer le flux d’air autour de l’appareil. Si l’appareil est exposé à de l’air salé, utilisez un appareil extérieur spécialement conçu pour résister à la corosion. 47 INSTRUCTIONS D’INSTALLATION Étape 2 : installation du raccord d’évacuation Avant de boulonner l’appareil extérieure en place, vous devez installer le raccord d’évacuation en dessous de l’appareil. 1. Installez le joint d’étanchéité en caoutchouc sur l’extrémité de raccord d’évacuation qui sera reliée à l’appareil extérieure. 2. Insérez le raccord d’évacuation dans le trou de l’entonnoir de la base de l’appareil. 3. Faites pivoter le raccord d’évacuation à 90° jusqu’à ce qu’il s’encliquette en place, face à l’avant de l’appareil. 4. Installez un raccord de tuyau d’évacuation (non fourni) sur le raccord d’évacuation que vous venez d’encliqueter sur l’unité pour rediriger l’eau provenant de l’unité en mode chauffage. Le trou de base pour le joint de drain se trouve au bas de l’appareil. En cas de climats froids En cas de climats froids, assurez-vous que le raccord d’évacuation est aussi vertical que possible, ce qui garantira la rapidité d’évacuation de l’eau. Si l’eau est évacuée trop lentement, elle peut geler dans le tuyau et submerger l’appareil. 48 INSTRUCTIONS D’INSTALLATION Étape 3 : ancrage de l’appareil extérieure L’appareil extérieure peut être ancrée au sol ou installée sur un support fixé au mur. Voici une liste des tailles d’appareils extérieurs et la distance entre leurs pieds de montage. Préparez la base d’installation de l’appareil en fonction des dimensions et des images ci-dessous. Numéro de modèle DAS180DBAHWDB Tableau des dimensions de montage de l’appareil Distance A Dimensions d’appareil (L x H x P) (mm / po) 922x715x379 (36.3”x28.2”x14.9”) 540 (21.26”) Distance B (mm / po) 350 (13.8”) AVERTISSEMENT Lors du forage dans le béton, la protection des yeux doit être portée en tout temps. Si vous prévoyez d’installer l’unité au sol ou sur une plateforme d’installation en béton, procédez comme suit: 1. Marquez les positions des quatre boulons expanseurs selon les dimensions du tableau dimensions d’installation d’appareil. 2. Prépercez des trous pour les boulons expanseurs. 3. Éliminez la poussière de béton des trous. 4. Placez un écrou à l’extrémité de chaque boulon expanseur. 5. Martelez les boulons expanseurs sur les trous prépercés. 6. Retirez les écrous des boulons expanseurs, puis placez l’unité extérieure sur les boulons. 7. Placez une rondelle sur chaque boulon expanseur, puis remettez les écrous en place. 8. À l’aide d’une clé, serrez chaque écrou jusqu’à ce qu’il le soit suffisamment. Si vous prévoyez d’installer l’unité sur un support fixé au mur, procédez comme suit: 1. Marquez les positions des trous du support en vous basant sur les dimensions du tableau dimensions d’installation d’appareil. 2. Prépercez des trous pour les boulons expanseurs. 3. Éliminez la poussière et les débris des trous. 4. Placez une rondelle et un écrou à l’extrémité de chaque boulon expanseur. 5. Faites passer les boulons expanseurs par les trous des supports de fixation, mettez les supports de fixation en place puis martelez les boulons expanseurs sur le mur. 6. Vérifiez que les supports de fixation sont à niveau. 7. Soulevez délicatement l’appareil et placez ses pieds de fixation sur les supports. 8. Boulonnez fermement l’appareil sur les supports. Remarque: Pour réduire les vibrations et le bruit d’un appareil monté sur un mur, installez l’appareil avec des joints en caoutchouc. 49 INSTRUCTIONS D’INSTALLATION Étape 4 : Connexion du câble de signal et du câble d’alimentation Le bornier de l’appareil extérieure est protégé par un cache-fils électriques. qui se trouve sur le côté de l’appareil. Un schéma de câblage complet est imprimé à l’intérieur du cache-fils. Superficie minimale de section Types de câble: • Câble d’alimentation intérieur (le cas échéant) : H05VV-F ou H05V2V2-F entre le câble d’alimentation et le câble de signal • Câble d’alimentation extérieur : H07RN-F • Câble de signal : H07RN-F Intensité nominale de AWG l’appareil (A) AVERTISSEMENT 10 18 Tout le câblage doit être effectué conformément au schéma de 13 16 câblage situé à l’intérieur du couvercle du fil de l’appareil intérieur. 18 14 Ne mélangez pas les fils en direct et nuls. Ceci est dangereux et peut provoquer un dysfonctionnement de l’appareil. 25 12 30 10 1. Préparez le câble pour le raccordement: a. À l’aide d’un outil à dénuder, retirez la garniture de caoutchouc des deux extrémités du câble de signal pour faire apparaître environ 40 mm (1.57 pouces) des fils qu’elle renferme. b. Dénudez l’isolation des extrémités des fils. c. À l’aide d’une pince à sertir, sertissez des cosses en U aux extrémités des fils. 2. Dévissez le cache-fils électriques et retirez-le. 3. Dévissez le serre-câble qui se trouve sous le bornier et placez-le sur le côté. 4. Associez les couleurs/étiquettes des fils en vous basant sur les étiquettes du bornier, puis vissez fermement la cosse en U de chaque fil sur la borne qui lui correspond. 5. Après avoir vérifié que tous les raccordements sont bien en place, formez une boucle avec les fils pour éviter que l’eau de pluie ne submerge les bornes. 6. À l’aide du serre-câble, fixez le câble sur l’unité. Vissez fermement le serre-câble. 7. Isolez les fils inutilisés avec du ruban électrique PVC. Organisez ces fils de manière à ce qu’ils ne touchent pas les pièces électriques ou métalliques 8. Remettez le cache-fils en place sur le côté de l’unité, puis vissez-le. Cache Remarque: Lorsque vous sertissez les fils, assurezvous de bien distinguer le fil sous tension (« L ») des autres fils. Schéma de câblage d’appareil extérieure qui se situe dans le cache-fils de cette appareil. 50 INSTRUCTIONS D’INSTALLATION RACCORDEMENT DE LA TUYAUTERIE DE RÉFRIGÉRANT La longueur de la tuyauterie de réfrigérant affectera les performances et l’efficacité énergétique de l’appareil. L’efficacité nominale est testée sur des unités dont la longueur de conduite est de 5 mètres (16,5 pieds). INSTRUCTIONS DE RACCORDEMENT – TUYAUTERIE DE RÉFRIGÉRANT Étape 1 : découpe des conduites Lorsque vous préparez les conduites de réfrigérant, redoublez de prudence pour les découper et les évaser correctement. Cela garantira l’efficacité du fonctionnement et minimisera le besoin de maintenance ultérieure. 1. Mesurez la distance séparant l’unité intérieure de l’unité extérieure. 2. À l’aide d’un coupe-tube, découpez une longueur de conduite légèrement plus importante que la distance mesurée. 3. Veillez à découper la conduite en respectant un angle parfait de 90°. Remarque: Ne pas endommager, bosse ou déformer le tuyau pendant la coupe. Cela réduira considérablement l’efficacité de chauffage de l’unité. Étape 2 : élimination des ébarbures Les ébarbures peuvent affecter l’étanchéité du joint de raccordement de la tuyauterie de réfrigérant. Elles doivent être totalement éliminées. 1. Maintenez le tuyau incliné vers le bas pour éviter que les bavures ne pénètrent à l’intérieur du tube. 2. À l’aide d’un alésoir ou d’un ébavureur, retirez les bavures de la section du tuyau coupé. 51 INSTRUCTIONS D’INSTALLATION Étape 3 : évasement des extrémités de conduite Il est essentiel d’évaser correctement la conduite pour obtenir une étanchéité hermétique. 1. Après avoir ébarbé les rebords du tuyau coupé, scellez ces extrémités avec du ruban PVC pour empêcher tout corps étranger de pénétrer à l’intérieur du tube. 2. Gainez le tube avec un matériau isolant. 3. Placez des écrous évasés aux deux extrémités de la conduite. Assurez-vous qu’ils sont orientés dans la bonne direction. Vous ne pourrez plus en remettre ou changer leur direction après l’évasement. 4. Retirez le ruban PVC des deux extrémités de la conduite une fois que vous êtes prêt à procéder à l’évasement. 5. Fixez le gabarit d’évasement à l’extrémité du tuyau. L’extrémité de la conduite doit s’étendre au-delà du bord de la forme d’évasement, en respectant les dimensions indiquées dans le tableau ci-dessous. EXTENSION DE LA TUYAUTERIE AU-DELÀ DE LA FORME D’ÉVASEMENT Diamètre externe de la conduite (mm) Dimension A Minimum (mm) Dimension A Maximum (mm) Ø 6.35 (Ø 0.25 po) 0.7 (0.0275 po) 1.3 (0.05 po) Ø 9.52 (Ø 0.375 po) 1.0 (0.04 po) 1.6 (0.063 po) Ø 12.7 (Ø 0.5 po) 1.0 (0.04 po) 1.8 (0.07 po) Ø 16 (Ø 0.63 po) 2.0 (0.078 po) 2.2 (0.086 po) 6. Placez l’outil à évaser dans la forme. 7. Tournez le manche de l’outil à évaser dans le sens horaire jusqu’à ce que la conduite soit entièrement évasée. 8. Retirez l’outil à évaser et la forme d’évasement, puis inspectez l’extrémité de la conduite à la recherche de fissures et pour vérifier si l’évasement est régulier. 52 INSTRUCTIONS D’INSTALLATION Étape 4 : raccordement des conduites Lorsque vous raccordez les conduites de réfrigérant, veillez à ne pas employer un couple excessif et à ne pas déformer la tuyauterie de quelque manière que ce soit. Vous devez d’abord raccorder la conduite basse pression, puis la conduite haute pression. Remarque: Lorsque vous coudez la tuyauterie de raccordement pour réfrigérant, le rayon minimal du coude est de 10 cm. INSTRUCTIONS DE RACCORDEMENT DE LA TUYAUTERIE À L’APPAREIL INTÉRIEURE 1. Alignez le centre des deux conduites que vous allez raccorder. 2. Serrez l’écrou évasé aussi fermement que possible à la main. 3. À l’aide d’une tricoise, serrez l’écrou sur la tubulure de l’unité. 4. Tout en serrant fermement l’écrou et la tubulure de l’unité, utilisez une clé dynamométrique pour serrer l’écrou évasé en respectant les valeurs de couple du tableau Exigences de couple qui figure ci-dessous. Desserrez légèrement l’écrou évasé, puis resserrez-le. Une force excessive pourrait briser l’écrou ou endommager la tuyauterie de réfrigérant. Vous ne devez pas dépasser les exigences de couple indiquées dans le tableau ci-dessus. Diamètre externe de la conduite (mm) Ø 6.35 (Ø 0.25 po) Ø 9.52 (Ø 0.375 po) Ø 12.7 (Ø 0.5 po) Ø 16 (Ø 0.63 po) EXIGENCES DE COUPLE Couple de serrage (N•cm) 1,500 (11 livres•pied) 2,500 (18.4 livres•pied) 3,500 (25.8 livres•pied) 4,500 (19 livres•pied) 53 Couple de serrage supplémentaire (N•m) 1,600 (11.8 livres•pied) 2,600 (19.18 livres•pied) 3,600 (26.55 livres•pied) 4,700 (34.67 livres•pied) INSTRUCTIONS D’INSTALLATION INSTRUCTIONS DE RACCORDEMENT DE LA TUYAUTERIE À L’APPAREIL EXTÉRIEURE 1. Dévissez le couvercle de la vanne à presse-étoupe qui se trouve sur le côté de l’appareil extérieure. 2. Retirez les capuchons de protection des extrémités des vannes. 3. Alignez l’extrémité évasée de chacune des conduites avec chacune des vannes, puis serrez l’écrou évasé aussi fermement que possible à la main. 4. À l’aide d’une tricoise, serrez le corps de la vanne. Ne serrez pas l’écrou étanchéifiant la vanne de service. 5. Tout en serrant fermement le corps de la vanne, utilisez une clé dynamométrique pour serrer l’écrou évasé en respectant les valeurs de couple appropriées. 6. Desserrez légèrement l’écrou évasé, puis resserrez-le. 7. Répétez les étapes 3 à 6 pour la conduite restante. 54 INSTRUCTIONS D’INSTALLATION PURGE DE L’AIR Préparations et précautions Si de l’air ou un matériau étranger est présent dans le circuit de réfrigérant, cela peut entraîner une pression anormale dans les conduites, qui à son tour peut endommager le climatiseur, réduire son efficacité et occasionner des blessures. Utilisez une pompe à vide et un manomètre pour purger le circuit de réfrigérant. Vous éliminerez ainsi les gaz non condensables et l’humidité du système. La purge doit être effectuée dès la première installation et lorsque l’unité est déplacée. Avant de procéder à la purge: • Effectuez une vérification pour vous assurer que la conduite basse pression et que la conduite haute pression qui relient l’unité intérieure et l’unité extérieure sont toutes deux correctement. • Effectuez une vérification pour vous assurer que tout le câblage est correctement connecté. Instructions pour la purge Avant d’utiliser une pompe à vide et un manomètre, lisez leurs modes d’emploi pour vous familiariser avec la méthode d’utilisation appropriée. 55 INSTRUCTIONS D’INSTALLATION Instructions pour la purge 1. Raccordez le tuyau de chargement du manomètre à l’orifice de service de la vanne basse pression de l’unité extérieure. 2. Raccordez un autre tuyau de chargement du manomètre à la pompe à vide. 3. Ouvrez le côté basse pression du manomètre. Laissez le côté haute pression fermé. 4. Allumez la pompe à vide pour purger le système. 5. Faites-la fonctionner pendant au moins 15 minutes, ou jusqu’à ce que le compteur combiné affiche -76 cmHG (-105 kPa). 6. Fermez le côté Basse pression du manomètre, puis éteignez la pompe à vide. 7. Patientez 5 minutes, puis vérifiez que la pression du système est bien restée inchangée. 8. Si la pression du système a changé, reportezvous à la section Recherche de fuites de gaz pour obtenir des informations sur la méthode de recherche des fuites. Si la pression du système n’a pas changé, dévissez le capuchon de la vanne à presse-étoupe (vanne haute pression). 9. Insérez une clé hexagonale dans la vanne à presse-étoupe (vanne haute pression) et ouvrez la vanne en tournant la clé d’un quart de tour dans le sens antihoraire. Écoutez pour entendre si des gaz sortent du système, puis refermez la vanne après 5 secondes. 10. Observez le manomètre pendant une minute pour vous assurer que la pression du système n’a pas changé. Le manomètre devrait afficher une pression légèrement plus élevée que la pression atmosphérique. 11. Retirez le tuyau de chargement de l’orifice de service. 12. À l’aide d’une clé hexagonale, ouvrez complètement les deux vannes : la vanne basse pression et la vanne haute pression.. 13. Serrez à la main les capuchons de la totalité des trois vannes (la vanne de service, la vanne basse pression et la vanne haute pression). Si nécessaire, vous pouvez les serrer davantage à l’aide d’une clé dynamométrique. AVERTISSEMENT NE MÉLANGEZ PAS PLUSIEURS TYPES DE RÉFRIGÉRANT 56 INSTRUCTIONS D’INSTALLATION Remarque: La vanne ouverte se dégage doucement. Lorsque vous ouvrez les tiges de la soupape, tournez la clé hexagonale jusqu’à ce qu’elle frappe le bouchon. N’essayez pas de forcer la vanne à ouvrir davantage. Remarque: Certains systèmes nécessitent une charge supplémentaire en fonction des longueurs de tuyau. La longueur standard du tuyau varie selon les réglementations locales. Par exemple, en Amérique du Nord, la longueur standard de la conduite est de 7,5 m (25 pieds). Dans d’autres domaines, la longueur standard du tube est de 5 m (16 pieds). Le réfrigérant supplémentaire à charger peut être calculé en utilisant la formule ci-dessous. Réfrigérant supplémentairepar longueur de conduite Longueur de la tuyauterie de raccordement (m) < Longueur de tuyau standard Méthode de purge de l’air Pompe à vide Réfrigérant supplémentaire N/A Côté liquide: Ø 6,35 (ø 0,25 po) > Longueur de tuyau standard Pompe à vide Côté liquide: Ø 9,52 (ø 0,375 po) R410a: R410a: (Longueur de tuyau - LS) x 15g/m (Longueur de tuyau - LS) x 30g/m (Longueur de tuyau - LS) x 0.16oZ/ft (Longueur de tuyau - LS) x 0.32oZ/ft LS = Longueur Standard 57 INSTRUCTIONS D’INSTALLATION RECHERCHES DE FUITES ÉLECTRIQUES ET DE FUITES DE GAZ Vérifications de sécurité électrique Après l’installation, vérifiez que tout le câblage est installé conformément aux réglementations locales et nationales, ainsi qu’au manuel d’installation. Vérifiez la mise à la terre Évaluez visuellement la résistance de la mise à la terre et mesurez-la avec un testeur de résistance de la mise à la terre. La résistance de mise à la terre doit être inférieure à 4. Recherche de fuite électrique During the test run, use an electroprobe and multimeter to perform a comprehensive electrical leakage test. Si vous détectez une fuite électrique, éteignez immédiatement l’unité et contactez un électricien habilité à la détection et à la résolution des fuites électriques. AVERTISSEMENT TOUT LE CÂBLAGE DOIT ÊTRE CONFORME AUX CODES ÉLECTRIQUES LOCAUX ET NATIONAUX ; IL DOIT EN OUTRE ÊTRE INSTALLÉ PAR UN ÉLECTRICIEN HABILITÉ. Recherche des fuites de gaz Deux méthodes différentes permettent de rechercher les fuites de gaz. Méthode à l’eau savonneuse À l’aide d’une brosse douce, appliquez de l’eau savonneuse ou du détergent liquide sur tous les points de raccordement de l’unité intérieure et de l’unité extérieure. La présence de bulles indique qu’il y a une fuite. Méthode avec détecteur de fuite Si vous utilisez un détecteur de fuite, à son mode d’emploi pour obtenir les instructions d’utilisation appropriées. Remarque: Après avoir vérifié qu’il n’y aucune fuite au niveau d’aucun des points de raccordement des conduites, remettez le couvercle de la vanne de l’unité extérieure en place. 58 INSTRUCTIONS D’INSTALLATION EXÉCUTER LE TEST Avant la série de tests, vérifiez que le système électrique de l’unité est sécurisé et qu’il fonctionne correctement. Vérifiez tous les raccordements à écrou évasé et assurez-vous que le système ne présente aucune fuite. Vérifiez que les vannes de gaz et de liquide (haute pression et basse pression) sont entièrement ouvertes. Instructions pour la série de tests 1. Branchez l’unité pour qu’elle soit alimentée. 2. Appuyez sur le bouton ON/OFF (Marche/arrêt) de la télécommande pour l’allumer. 3. Appuyez sur le bouton MODE (Mode) pour faire défiler les fonctions suivantes, une à une: • COOL (REFROIDISSEMENT) : choisissez la température la plus faible possible • HEAT (CHAUFFAGE) : sélectionnez la température la plus élevée possible 4. Laissez chacune des fonctions s’exécuter pendant 5 minutes, puis effectuez les vérifications suivantes: • • • • • • • • • • • Aucune fuite électrique L’unité est correctement reliée à la terre Toutes les bornes électriques sont correctement recouvertes L’unité intérieure et l’unité extérieure sont solidement installées Aucun des points de raccordement des conduites ne fuit L’eau s’écoule correctement du tuyau d’évacuation Toute la tuyauterie est correctement isolée La fonction REFROIDISSEMENT de l’unité s’exécute correctement La fonction CHAUFFAGE de l’unité s’exécute correctement Les aérateurs à lames de l’unité intérieure tournent correctement L’unité intérieure réagit à la télécommande IMPORTANT: La pression du circuit de réfrigération augmentera lors de cette opération. Cette opération peut permettre de découvrir des fuites qui n’avaient pas été détectées lors de votre recherche initiale de fuite. Au cours de la série de tests, prenez le temps de revérifier tous les points de raccordement des conduites de réfrigérant pour vous assurer qu’ils ne fuient pas. 5. Une fois que vous aurez terminé la série de tests avec succès, utiliser la télécommande, rétablissez la température de fonctionnement normale de l’appareil. À l’aide d’un ruban isolant, enveloppez les raccordements de conduites de réfrigérant que vous avez laissés à nu lors du processus d’installation de l’appareil. Test exécuté en basse température Si la température ambiante est inférieure à 17°C (63°F), vous ne pouvez pas utiliser la télécommande pour activer la fonction REFROIDISSEMENT. Dans un tel cas, vous pouvez utiliser le bouton MANUAL CONTROL (CONTRÔLE MANUEL) pour tester la fonction REFROIDISSEMENT. 1. Soulevez le panneau avant de l’unité intérieure, puis levez-le jusqu’à ce qu’il s’encliquette en place. 2. Le bouton MANUAL CONTROL (CONTRÔLE MANUEL) se situe du côté droit de l’unité. Appuyez deux fois dessus pour sélectionner la fonction COOL (REFROIDISSEMENT). 3. Effectuez la série de tests comme habituellement. Lignes directrices pour l’élimination Cet appareil contient du réfrigérant et d’autres matériaux potentiellement dangereux. Lorsque vous mettez cet appareil au rebut, la loi exige que vous preniez des mesures particulières pour la collecte et le traitement des déchets. Ne mettez pas ce produit au rebut comme s’il s’agissait de déchets ménagers ou de déchets municipaux non triés. 59 LIMITED IN-HOME APPLIANCE WARRANTY GARANTIE LIMITÉE DE L'APPAREIL This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. Cet de qualité garanti exempt vicesold debymatière première et de fabrication, s’il est utilisé dans les Thisappareil warranty is available only to est the person to whom the unitde wastout originally Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter conditions normales recommandées par le fabricant. “Danby”) or by an authorized distributor of Danby, and is non-transferable. Cette garantie n’est offerte qu’à l’acheteur initial de l’appareil vendu par Danby Products Limited (Canada) ou Danby Products Inc. (E.- U.A.) (ci-après « Danby ») ou par l’un des ses distributeurs agréés et elle ne peut être transférée. TERMS OF WARRANTY Plastic parts, are warranted for thirty (30) days only from purchase date, with CONDITIONS no extensions provided. Les pièces en plastique sont garanties pendant trente (30) jours seulement à partir de la date de l’achat, sans aucune First Year During the first twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s prolongation prévue. option, at no charge to the ORIGINAL purchaser. Premiers 24 mois Pendant les premiers vingt quatre (24) mois, toutes les pièces fonctionnelles de ce produit qui s’avèrent défectueuses seront réparées ou remplacées, selon le choix du garant, sans frais à To obtain Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance l’acheteur INITIAL. Service requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at own expense) to the original retailer (point of que purchase) or a service depot repair.responsable See “Boundaries ofdes In Home Serv ice” below. Aucune partie de latheir garantie ne prévoit implicitement le fabricant serafortenu dommages subis par Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service les aliments ou d’autres types de contenu, qu’ils soient causés par la défectuosité de l’appareil ou par son usage must be performed by a qualified service technician. adéquat ou inadéquat. If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all obligations of Danby under this warranty shall be void. EXCLUSIONS EnBoundaries vertu de la présente, il n’existe aucune autre garantie, condition représentation, qu’elle soit ou tacite, of If the appliance is installed in a location that is 100 kilometers (62 miles)ou or more from the nearest service center yourexprimée unit must be deIn Home façonService manifeste delivered ou intentionnelle, par Danby ou ses distributeurs agréés. De même, sont exclues toutes les autres to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualified and certif ied for garanties, conditions ou représentations, y compris lestogaranties, conditions ounot représentations en vertu warranty service by Danby. Transportation charges and from the service location are protected by this warranty and arede t touteheloi the de purchaser. régissant la vente deresponsibility produitsofou toute autre législation ou règlement semblables. En vertu de la présente, Danby ne peut être tenue responsable en cas de blessures corporelles ou des dégâts matériels, y compris à l’appareil, quelle qu’en lesthiscauses. Danby neDanby peutwill pas être tenue responsable des dommages auoffonctionnement Nothingsoit within warranty shall imply that be responsible or liable for any spoilage or damage to food orindirects other c dus ontents this appliance, whether due to any defect ofde thel’appareil. appliance, or its use, proper or improper. l’acheteur accepte de mettre à couvert et de dégager Danby de toute défectueux En whether achetant l’appareil, responsabilité en cas de réclamation pour toute blessure corporelle ou tout dégât matériel causé par cet appareil. EXCLUSIONS Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its CONDITIONS GÉNÉRALES distributors and all otherci-dessus warranties, conditions, representations including any warranties, conditio ns, representations or guarantees Laauthorized garantie ou assurance ne s’applique pasorsiguarantees, les dégâts ou réparations sont dus aux cas suivants: under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of 1) Panne de courant. the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit. 2) Dommage subis pendant le transport ou le déplacement de l’appareil. 3) Alimentation électrique incorrecte (tension faible, câblage défectueux, fusibles incorrects). GENERAL PROVISIONS tel qu'une circulation d'air inadéquate dans la pièce 4) Accident, modification, emploi abusif ou incorrect de l’appareil No warranty or insurance herein contained or set out shall apply when damage or repair caused by any of the following: ou des conditions de fonctionnement anormales (température isextrêmement élevée ou basse). 1) Power failure. 5) Utilisation dans un but commercial ou industriel (à savoir, si l'appareil n'est pas installé dans un domicile résidentiel). 2) Damage in transit or when movingpar the appliance. 6) Incendie, dommages causés l’eau, vol, guerre, émeute, hostilités, cas de force majeure (ouragan, inondation, etc.). 3) Improper power supply such as low voltage, defective house wiring or inadequate fuses. 4) Accident, alteration, abuse or misuse of the appliance such as inadequate air in the au roompropriétaire. or abnormal operating con ditions 7) Visites d’un technicien pour expliquer le fonctionnement decirculation l’appareil (extremely high or low room(par temperature). 8) Installation inappropriée exemple, encastrement d'un appareil autoportant, ou utilisation extérieure d'un 5) Use forconçu commercial or industrial appareil non à cet effet).purposes (ie. If the appliance is not installed in a domestic residence). 6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc. Une preuve d’achat doitinêtre présentée 7) Service calls resulting customer education. pour toute demande de réparation sous garantie. Prière de garder le reçu. 8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application). Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our AUTHORIZED SERVICE DEPOT. Warranty Service In-home Danby Products Limited Danby Products Limited PO 1778, Guelph, N1H 6Z9 POBox Box 1778, Guelph, Ontario, Ontario, Canada N1HCanada 6Z9 Téléphone : (519) 837-0920 Télécopieur: (519) 837-0449 Telephone: (519) 837-0920 FAX: (519) 837-0449 1-800-263-2629 1-800-263-2629 12/19 04/09 Danby Products Danby Products Inc. Inc. PO BoxPO669, Findlay, Ohio, U.S.A. Box 669, Findlay, Ohio, U.S.A. 45840 45840 Téléphone: (419)Telephone: 425-8627 (419) 425-8629 (419) Télécopieur: 425-8627 FAX: (419) 425-8629 Informacion de Seguridad Importante LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD PRECAUCIONES DE SEGURIDAD La instalación incorrecta debido a ignorar o hacer caso omiso a las instrucciones puede causar serios daños o lesiones. • Al conectar tuberías/líneas del refrigerante, no deje que sustancias o gases que no sean del tipo de refrigerante especificado entren en las líneas, ya que esto reducirá la capacidad de la unidad y puede causar una presión alta anormal en el sistema de refrigeración, lo que puede provocar una explosión o lesiones. • La instalación debe ser realizada por un técnico certificado en Aire Acondicionado. La instalación incorrecta puede causar fugas de agua, descargas eléctricas o incendio. • En Norte América (EE.UU), la instalación debe realizarse de acuerdo con los estándares y normas de NEC y CEC, sólo por personal autorizado. • Favor de ponerse en contacto con un técnico especializado en Aire Acondicionado o con el agente de ventas para obtener información sobre la reparación o el mantenimiento de este producto/unidad. • Utilice únicamente los accesorios, piezas y partes especificadas para la instalación. El uso de partes - no estándar - pudieran ocasionar fugas de agua, descargas eléctricas, incendios y puede causar fallos de esta unidad. • Instale este producto/unidad en una ubicación firme que pueda soportar el peso de la unidad. Si el lugar elegido no puede soportar el peso de la unidad , o si la instalación no se ha hecho correctamente, la unidad puede caerse y causar graves lesiones o daños. • Para todos los trabajos eléctricos, siga todas las normas y reglamentos locales /nacionales de cableado, así como las indicadas en este y este manual. Debe utilizar un circuito independiente y un solo enchufe/ toma corriente para suministrar energía. No conecte otros aparatos en el mismo toma de corriente. La insuficiencia de capacidad eléctrica o los defectos en el trabajo eléctrico pueden causar descargas eléctricas o incendios. • Para todos los trabajos eléctricos, utilice todos los cables especificados. Conecte los cables firmemente y sujételos en forma segura para evitar que las fuerzas externas dañen el terminal. Las conexiones eléctricas inadecuadas pueden recalentarse y provocar descargas eléctricas o incendios. • Todos los cables deben estar correctamente colocados para asegurar que la tarjeta de control pueda cerrarse correctamente. Si la cubierta de la tarjeta de control no está cerrada correctamente, puede provocar corrosión y causar que los puntos de conexión del terminal se sobrecalienten, se incendien o provoquen una descarga eléctrica. • En algunos ambientes o áreas, como cocinas, salas de computo etc., se recomienda el uso de unidades de aire acondicionado diseñadas especialmente para ese propósit. • Esta unidad no está diseñado para ser usado por personas (incluyendo niños) cuyas capacidades físicas, sensoriales o mentales puedieran ser diferentes o reducidas, o que carezcan de experiencia o conocimiento, a menos que dichas personas reciban supervisión o entrenamiento para operar la unidad por una persona responsable de su cuidado y seguridad. • No instale la unidad en un lugar que pueda estar expuesto a fugas de gas combustible. Si se acumula gas combustible alrededor de la unidad, podría provocar un incendio. • No utilice esta unidad en un cuarto húmedo, como un cuarto de baño o cerca de un lavadero. Demasiada exposición al agua puede causar cortocircuitos en los componentes eléctricos. • Esta unidad deberá de estar debidamente conectado a tierra o puede producirse una descarga eléctrica. • Instale la tubería de drenaje de acuerdo con las instrucciones de este manual. Un drenaje inadecuado puede causar daños por agua. NOTA SOBRE LOS GASES FLUORADOS • Esta unidad contiene gases fluorados. Para obtener mas información específica sobre el tipo y la cantidad de gas, consulte la etiqueta correspondiente en el propio equipo. • La instalación, servicio, mantenimiento y reparación de este electrodoméstico deben ser realizados por un técnico certificado en Aire Acondicionado. • La desinstalación y el reciclaje deben ser realizados por un técnico certificado en Aire Acondicionado. • Si la unidad esta equipada con un sistema de detección de fugas, deberá de verificar que no haya fugas al menos cada 12 meses. Cuando se comprueba si hay fugas en la unidad, es altamente recomendable que se mantengan registros de todas las verificaciones. GARDER CES INSTRUCTIONS! 61 INSTRUCCIONES DE INSTALACIÓN ACCESORIOS El sistema de aire acondicionado viene con los siguientes accesorios. Utilice todas las piezas de instalación y accesorios para instalar el acondicionador de aire. Una instalación incorrecta puede ocasionar fugas de agua, descargas eléctricas, incendio o puede causar que el equipo falle. Parte Imagen Cantidad Placa de montaje 2 Tornillo de fijación de la placa de montaje ST3.9 x 25 10 Anclajes tipo clip 10 Control remoto 2 Pilas secas AAA.LR03 4 Sello 2 Articulación de drenar 2 62 INSTRUCCIONES DE INSTALACIÓN RESUMEN DE LA INSTALACIÓN Placa de montaje mural Panel frontal Cable de energía Persiana Tubo de drenaje Filtro Funcional En el frente del filtro principal Cable de señal Tubería de refrigerante Control remoto Unidad exterior Cable de energía Nota: Las ilustraciones de este manual son sólo para propósitos explicativos. La forma real del aparato puede ser ligeramente diferente. La forma real prevalecerá. Nota: El modelo DAS180DBAHWDB se puede conectar a múltiples unidades interiores. Vea la página siguiente para más detalles. 63 INSTRUCCIONES DE INSTALACIÓN RESUMEN DE LA INSTALACIÓN Al instalar varias unidades interiores en una sola unidad exterior, asegúrese de que la longitud del tubo de refrigerante y la altura de caída entre las unidades interior y exterior cumplan los siguientes requisitos: Unidad exterior Unidad interior Unidad exterior 49ft (15m) 32.8ft (10m) 49ft (15m) Unidad exterior Unidades interiores que se pueden Cantidad de unidades usar en combinación conectadas Frecuencia de parada / arranque del Para el tiempo compresor Fluctuación de voltaje Caída de voltaje durante Voltaje de la fuente de alimentación el inicio Desbalance de intervalo Las unidades están en metros / pies Max. longitud para todas las habitaciones Max. longitud para una unidad interior Max. diferencia de altura entre interior y exterior Max. diferencia de altura entre unidades interiores 1 unidad 2 40/131 25/82 15/49 10/33 64 1 - 5 unidades 3 minutos o más dentro de ±10% del voltaje nominal dentro de ±15% del voltaje nominal dentro de ±3% del voltaje nominal 1 unidad 3 60/197 30/98 15/49 10/33 1 unidad 4 80/262 35/115 15/49 10/33 1 unidad 5 80/262 35/115 15/49 10/33 INSTRUCCIONES DE INSTALACIÓN RESUMEN DE LA INSTALACIÓN - UNIDAD INTERIOR 65 INSTRUCCIONES DE INSTALACIÓN RESUMEN DE LA INSTALACIÓN - UNIDAD INTERIOR 66 INSTRUCCIONES DE INSTALACIÓN INSTALACIÓN DE UNIDAD INTERIOR Antes de instalar la unidad interior, consulte la etiqueta de la caja del producto para asegurarse de que el número de modelo de la unidad interior coincida con el número de modelo de la unidad exterior. El número de modelo de la unidad interior terminará con un “-I” y el número de modelo de la unidad exterior finalizará con un “-O”, de lo contrario deberán ser idénticos. Paso 1: Seleccione el lugar adecuado para la instalación Los lugares adecuados de instalación cumplen con los siguientes estándares: • • • • • • Buena circulación de aire. Drenaje adecuado. El ruido producido por operación de la unidad no molesta a las personas o animales. Ubicación firme y sólida para evitar la vibración Suficientemente fuerte para soportar el peso de la unidad. Al menos 1 m (3 pies) de distancia de todos los demás dispositivos eléctricos, como televisores, radios y computadoras, lo que podría afectar a la señal remota de infrarrojos. No instale la unidad interior en lugares que tengan lo siguientes condiciones: • • • • • Cerca de cualquier fuente de calor, vapor o gas combustible. Cerca de artículos inflamables como cortinas o ropa. Cerca de cualquier obstáculo que pueda bloquear la circulación del aire. Cerca de cualquier puerta. Donde la exposición a luz solar sea directa Refiérase a la siguiente ilustración para asegurar la distancia apropiada de las paredes circundantes y del techo: 67 INSTRUCCIONES DE INSTALACIÓN Paso 2: Fije la placa para montaje a la pared La placa de montaje es el dispositivo que sujeta la unidad interior a la pared. 1. Quite el tornillo que une la placa de montaje a la parte posterior de la unidad interior. 2. Coloque la placa de montaje contra la pared en el lugar donde se instalará la unidad interior. 3. Perfore agujeros para los tornillos de montaje, asegurándose de que los tornillos entren en los montantes de pared que pueden soportar el peso de la unidad. 4. Fije la placa de montaje a la pared con los tornillos suministrados. Asegúrese de que la placa de montaje esté plana contra la pared. Nota: Si la pared está hecha de ladrillo, concreto o material similar, taladre orificios de 5 mm (0,2 pulgadas) De diámetro en la pared e inserte los anclajes de manguito suministrados. Asegure la placa de montaje a la pared apretando los tornillos en los anclajes tipo clip. Dimensiones de la placa de montaje Los diferentes modelos tienen diferentes placas de montaje. Para asegurarse de que haya espacio suficiente para montar la unidad interior, verifique los diagramas que se muestran a continuación, los cuales muestran los dos tipos diferentes de placas de montaje con las siguientes dimensiones: • • • • • Ancho de la placa de montaje. Alto de la placa de montaje. Ancho de la unidad interior respecto a la placa de montaje. Alto de la unidad interior respecto a la placa de montaje. Posición recomendada del orificio de la pared, tanto a la izquierda como a la derecha de la unidad interior. • Distancia relativa entre los orificios de los tornillos. 3.7 cm (1.45”) Esquema de la unidad interior Orificio de la pared trasera izquierda 6.5 cm (2.5in) Orificio de la pared trasera derecha 6.5 cm (2.5”) 68 12.6 cm (4.96”) 80.2 cm (31.6”) 4.2 cm (1.65”) 22.9 cm (9.01”) 22.8 cm (8.98”) 5.8 cm (2.28”) 72.2 cm (28.45”) 40.1 cm (15.78”) 4.7 cm (1.85”) 29 cm (11.4”) 4.9 cm (1.95”) 13.6 cm (5.35”) 4.9 cm (1.95”) 17.9 cm (7.05”) 10.1 cm (4”) Orificio de la pared trasera izquierda 6.5 cm (2.5in) Modelo B 34.8 cm (13.7”) 29.7 cm (11.7”) Modelo A Esquema de la unidad interior Orificio de la pared trasera derecha 6.5 cm (2.5”) INSTRUCCIONES DE INSTALACIÓN Paso 3: Perforar en pared un orificio para la conexión de la tubería Se debe perforar un orificio a través de la pared hacia el exterior para acomodar la tubería del refrigerante, la tubería del drenaje y el cable de señalización/control que conectará las unidad interior y la unidad exterior. 1. Determine la ubicación del orificio de la pared en base a la posición de la placa de montaje. Consulte el Paso 2 para ver las dimensiones de la placa de montaje. 2. El orificio en la pared debe tener un diámetro de 65 mm (2,5 pulgadas) Y debe perforarse en ángulo hacia abajo para facilitar el drenaje. El extremo exterior del orificio debe ser inferior al extremo interior del orificio de 5 a 7 mm (0,2 - 0,275 pulgadas). 3. Coloque una banda de protección en el orificio. Esto protegerá los bordes del orificio y ayudará a sellar el orificio una vez que se complete la instalación. Nota: Al perforar el orificio en la pared, asegúrese de evitar hacer contacto con cables, plomería u otros componentes sensibles que podrían estar instalados dentro de la pared. 69 INSTRUCCIONES DE INSTALACIÓN Paso 4: Prepare tuberías del refrigerante La tubería del refrigerante está dentro de un paquete aislante unido a la parte posterior de la unidad. La tubería debe estar preparada antes de pasarla a través del orificio en la pared. Consulte la sección Conexión de la tubería del Refrigerante para obtener instrucciones detalladas sobre los requisitos de ensanchamiento de la tubería y requerimientos de torsión, etc. 1. Basándose en la posición del orificio en la pared con respecto a la placa de montaje, elija el lado desde el cual la tubería saldrá de la unidad. Panel de expulsión 2. Si el orificio de la pared está detrás de la unidad, deje el panel de desmontaje en su lugar. Si el orificio en la pared está al lado de la unidad interior, retire el panel de desmontaje de plástico del lado de la unidad. Esto creará una ranura a través de la cual la tubería puede salir de la unidad. Utilice pinzas de punta si el panel de plástico es difícil de quitar. 3. Use tijeras para cortar la longitud del paquete aislante para revelar aproximadamente 15 cm (6 pulgadas) de la tubería del refrigerante. Esto tiene dos propósitos: • Para facilitar el proceso de conexión de tuberías del refrigerante • Para facilitar la detección de fugas de gas y permitir una detección de posibles abolladuras en el tubo 4. Si ya existe una tubería de conexión incrustada en la pared, proceda directamente al Paso 5: Conecte la manguera de desagüe. Si no hay tubería incrustada, conecte la tubería del refrigerante de la unidad interior a la tubería de conexión que unirá las unidades interiores y exteriores. 5. De acuerdo en la posición en el orificio de la pared respecto a la placa de montaje, determine el ángulo necesario de la tubería. Agarre las tuberías del refrigerante en la base de la curva. 6. Lentamente, aplicando una presión uniforme, doble la tubería hacia el orificio en la pared. No doblar o dañar la tubería durante el proceso. Nota sobre el ángulo de tubería La tubería de refrigerante puede salir de la unidad interior desde cuatro ángulos diferentes: • • • • Lado izquierdo Izquierda trasera Lado derecho Izquierda trasera PRECAUCIÓN Tenga mucho cuidado de no abollar o dañar la tubería mientras la dobla lejos de la unidad. Cualquier abolladura en la tubería afectará el rendimiento de la unidad. 70 INSTRUCCIONES DE INSTALACIÓN Paso 5: Conecte la manguera de desagüe (drenaje) Por defecto, la manguera de desagüe está conectada al lado izquierdo de la unidad, cuando se mira hacia la parte posterior de la unidad. También se puede fijar a la derecha. 1. Para asegurar un drenaje adecuado, coloque la manguera de desagüe en el mismo lado de la unidad que la tubería del refrigerante. 2. Conecte la extensión de la manguera de desagüe (se vende por separado) al extremo de la manguera de desagüe. 3. Use cinta de teflón y envuelva el punto de conexión firmemente para asegurar un buen sellado y evitar fugas. 4. Para la parte de la manguera de desagüe que permanecerá en el interior, envuélvala con aislamiento de tuberías (espuma de polietileno) para evitar la condensación. 5. Retire el filtro de aire y vierta una pequeña cantidad de agua en la bandeja de drenaje para asegurarse de que el agua fluye al exterior de la unidad con facilidad. Nota sobre la colocación de la manguera de desagüe • Do not kink the drain hose. • No doble la manguera de desagüe. • No cree una trampa de agua. • No coloque el extremo de la manguera de desagüe en agua o en un recipiente que recoja agua. Nota: Para prevenir fugas no deseadas, enchufe el tapón de goma suministrado en el orificio de drenaje sin usar. Vea a continuación ejemplos para instalación correcta de la manguera de desagüe: 71 INSTRUCCIONES DE INSTALACIÓN ANTES DE REALIZAR EL TRABAJO ELECTRICO, LEA ESTAS NORMAS Y REGLAMENTOS 1. Todo el cableado debe cumplir con los códigos eléctricos locales/nacionales y debe ser instalado por un electricista calificado. 2. Todas las conexiones eléctricas deben realizarse de acuerdo al Diagrama de Conexión Eléctrica ubicado en los paneles de las unidades interior y exterior. 3. Si encuentra algún problema de seguridad grave con la fuente de alimentación, pare el trabajo inmediatamente. Explique su razonamiento al cliente y no instale la unidad hasta que se resuelva el problema de seguridad. 4. El voltaje de alimentación eléctrica debe estar en el 90 - 100% del voltaje especificada. Una fuente de alimentación insuficiente puede causar un mal funcionamiento, una descarga eléctrica o un incendio. 5. Si conecta la energía al cableado fijo, instale un protector contra sobretensión y un interruptor de alimentación principal con una capacidad de 1.5 veces la corriente máxima de la unidad. 6. Si se conecta energía a un cableado fijo, se debe incorporar un interruptor o disyuntor que desconecte todos los polos y que tenga una separación de contacto de al menos 3 cm (1,8 pulgadas.) En el cableado fijo. El técnico cualificado debe utilizar un apagador o interruptor de circuito aprobado. 7. Conecte la unidad únicamente a un circuito ramal independiente. No conecte otro aparato o equipo a ese toma corriente. 8. Asegúrese de poner a tierra correctamente la unidad. 9. Todos los cables deben estar firmemente conectados. Un cable flojo puede causar que el terminal se sobrecaliente, lo que provoca un mal funcionamiento del producto y un posible incendio. 10. No permita que los cables se toquen o se apoyen contra la tubería del refrigerante, el compresor o cualquier parte móvil dentro de la unidad. ADVERTENCIA ANTES DE REALIZAR CUALQUIER TRABAJO DE CABLEADO ELÉCTRICO, DESCONECTE LA ENERGIA PRINCIPAL DEL SISTEMA. ADVERTENCIA TODO EL CABLEADO DEBE REALIZARSE DE ACUERDO AL DIAGRAMA DE CABLEADO QUE SE ENCUENTRA EN EL INTERIOR DE LA CUBIERTA DE CABLE DE LA UNIDAD INTERIOR. NO MEZCLE CABLES VIVOS Y NULOS. ESTO ES PELIGROSO Y PUEDE CAUSAR UN MAL FUNCIONAMIENTO DE LA UNIDAD. 72 INSTRUCCIONES DE INSTALACIÓN Conecte el cableado a los terminales como se identifica con sus respectivos números coincidentes en el bloque de terminales de las unidades interior y exterior. Por ejemplo, consulte los siguientes modelos de US: El terminal L1 (A) en la unidad exterior debe conectarse con el terminal L1 en la unidad interior. Pase el cable de alimentación principal por la salida de la línea inferior de la abrazadera del cable. Uno-dos modelos: Modelo A Modelo E Modelo B Modelo C Modelo F 73 Modelo G Modelo D INSTRUCCIONES DE INSTALACIÓN Paso 6: Conecte el cable de señalización/control El cable de señalización y control permite la comunicación entre las unidades interior y exterior. Primero debe elegir el tamaño correcto del cable antes de prepararlo para la conexión. Tipos de cables: • Cable de alimentación interior (según corresponda): H05W-F o H05V2V2-F • Cable de alimentación exterior: H07RN-F • Cable de señalización: H07RN-F Área mínima transversal de los cables de alimentación y de señal ELIJA EL TAMANO/CALIBRE DEL CABLE CORRECTO Amperios (A) AWG El tamaño del cable de alimentación, el cable de señalización/ control, el fusible y el interruptor necesarios está determinado por 10 18 la corriente máxima en la unidad. La corriente máxima se indica 13 16 en la placa de características situada en el panel lateral de la unidad. Consulte esta placa de características para elegir el 18 14 cable, el fusible y el interruptor adecuados. 25 12 Tenga en cuenta las especificaciones de los fusibles 30 10 La tarjeta de circuitos del aire acondicionado (PCB) está diseñada con un fusible para proporcionar protección de sobre corriente. Las especificaciones del fusible están impresas en la tarjeta de circuitos, tales como: T3.15A / 250VAC, T5A / 250VAC, etc. Nota: Preste atención 1. Prepare el cable para la conexión: al cable con corriente a. Usando la herramienta para pelar cables (wire stripper), “vivo”. Mientras prense los desmonte la cubierta de plástico de ambos extremos del cable alambres, asegúrese de de señalización hasta pelar unos 40 mm (1,57 in) del interior del cable. distinguir el alambre con b. Tire el aislamiento de los extremos de los cables. corriente –vivo(“L”) y los c. Usando una herramienta para prensar terminales de cable otros cables (Wire crimper Tool) , prense las terminales tipo “u “en los extremos de los cables. 2. Abra el panel frontal de la unidad interior. 3. Con un destornillador, abra la tapa de la caja del cableado en el lado derecho de la unidad. Esto revelará el bloque de terminales. El diagrama de cableado se encuentra en el interior de la cubierta de cables de la unidad interior. 4. Desenrosque la abrazadera de cable debajo del bloque de terminales y colóquela a un lado. 5. Mirando la parte posterior de la unidad, retire el panel de plástico localizado en la parte inferior izquierda. 6. Pase el cable de señalización y control a través de esta ranura, desde la parte posterior de la unidad hacia el frente. 7. Mirando la parte frontal de la unidad, combine los colores de los hilos con las etiquetas en el bloque de terminales, conecte la u-lug y atornille firmemente cada cable a la terminal correspondiente. 8. Después de comprobar que todas las conexiones estén bien aseguradas, utilice la abrazadera para sujetar el cable de señalización a la unidad. Atornille firmemente la abrazadera del cable. 9. Vuelva a colocar la cubierta de cables en la parte frontal de la unidad y el panel de plástico en la parte posterior. 74 INSTRUCCIONES DE INSTALACIÓN Paso 7: Envuelva la tubería y los cables Antes de pasar la tubería, la manguera de drenaje y el cable de señalización a través del orificio de la pared, es necesario, atarlos/agruparlos, protegerlos y aislarlos de manera adecuada con la finalidad de ahorrar espacio. 1. Agrupe la manguera de desagüe, las tuberías de refrigerante y el cable de señalización. Nota: Asegúrese de que la manguera de desagüe esté en la parte inferior del paquete. La colocación de la manguera de desagüe en la parte superior del paquete puede hacer que la bandeja de desagüe se desborde, lo que pudiera provocar incendios o daños por agua. 2. Usando cinta adhesiva de vinilo, asegure la manguera de desagüe a la parte inferior de las tuberías de refrigerante. 3. Usando una cinta aislante, envuelva en conjunto el cable de señalización/control, las tubería del refrigerante y la manguera de desagüe, atándoles firmemente. Nota: Mientras se agrupa estos artículos juntos, no entrelaza ni cruza el cable de la señalización/control con cualquier otro cableado. Nota: Al agrupar mantenga los extremos de la tubería sin envolver. Ya que se requiere de su acceso para verificar si hay fugas al final del proceso de instalación. 75 INSTRUCCIONES DE INSTALACIÓN Paso 8: Montaje de la unidad interior Si se instaló una nueva tubería de conexión en la unidad exterior, complete lo siguiente: 1. Si la tubería del refrigerante ya ha pasado a través de la pared, continúe con el paso 4. 2. De lo contrario, verifique que los extremos de los tubos de refrigerante estén sellados para evitar que polvo o materiales extraños entren en las tuberías. 3. Pase lentamente el paquete envuelto de tuberías del refrigerante, la manguera de desagüe y el cable de señalización/control a través del orificio de la pared. 4. Enganche la parte superior de la unidad interior en el gancho superior de la placa de montaje. 5. Compruebe que la unidad esté enganchada firmemente en el montaje aplicando una ligera presión en ambos lados izquierdo y derecho de la unidad. La unidad no debería de moverse o voltearse. 6. Utilizando una presión uniforme, empuje hacia abajo la mitad inferior de la unidad. Mantenga presionando hacia abajo hasta que la unidad encaje en los ganchos a lo largo de la parte inferior de la placa de montaje. 7. Compruebe que la unidad esté firmemente montada aplicando una ligera presión a los lados izquierdo y derecho de la unidad. Si la tubería del refrigerante ya está incrustada en la pared, complete lo siguiente: 1. Enganche la parte superior de la unidad interior en el gancho superior de la placa de montaje. 2. Utilice un soporte o una cuña para apoyar la unidad, dejando suficiente espacio para conectar la tubería del refrigerante, el cable de señalización/control y la manguera de desagüe 3. Conecte la manguera de desagüe y la tubería del refrigerante. Consulte la sección Conexión de la tubería del refrigerante para obtener más información. 4. Mantenga el punto de conexión/unión de la tubería expuesto; a modo de poder realizar la prueba de fugas. Consulte la sección Comprobaciones eléctricas y Verificación de fugas para obtener más información. 5. Después de realizar la verificación de fugas, envuelva el punto de conexión/ uniones con cinta aislante. 6. Retire el soporte o la cuña que esta sosteniendo la unidad. 7. Utilizando una presión uniforme, empuje hacia abajo la mitad de la parte inferior de la unidad. Mantenga presionando hacia abajo hasta que la unidad encaje en los ganchos a lo largo de la parte inferior de la placa de montaje. Cuña La unidad es Ajustable Los ganchos de la placa de montaje son más pequeños que los agujeros en la parte posterior de la unidad. La unidad tiene una holgura de ajuste a la izquierda o a la derecha en aproximadamente 30 - 50 mm (1,25 - 1,95 in) dependiendo del modelo. 76 INSTRUCCIONES DE INSTALACIÓN INSTALACION DE LA UNIDAD EXTERIOR Paso 1: Seleccione la ubicación de instalación Antes de instalar la unidad exterior, elija una ubicación apropiada para la unidad. Los lugares de instalación adecuados cumplen con los siguientes requisitos: • • • • Buena ventilación y circulación de aire Firme y sólido; La ubicación debe poder soportar el peso de la unidad y prevenir vibración El ruido producido por la operación de la unidad no será molesto. La unidad deberá estar protegida de períodos prolongados a la exposición directa de luz solar, lluvia o nieve. • La ubicación debe cumplir con los requisitos especiales que se describen a continuación: No instale la unidad en los siguientes lugares: • Cerca de obstáculos bloqueando las entradas o salidas de aire. • Cerca de una calle pública, en áreas con mucha gente o donde el ruido de la unidad pudiera molestar a otros. • Cerca de animales o plantas que pudieran resultar dañados por la descarga de aire caliente. • Cerca de cualquier fuente de gas combustible. • En lugares expuesto a grandes cantidades de polvo. • En lugares expuesto a grandes cantidades de aire o ambiente con sal. Consideraciones especiales para instalación en climas extremos En caso de que la unidad está expuesto a fuertes vientos, instale la unidad de modo que el ventilador de salida de aire esté en un ángulo de 90 ° con la dirección del viento. Si es necesario, construya una barrera delante de la unidad para protegerla del viento. En caso de que la unidad está expuesta a fuertes lluvias o nieve, construya un refugio sobre la unidad para protegerla de la lluvia o la nieve. Tenga cuidado de no obstruir el flujo de aire alrededor de la unidad. En caso de que la unidad está expuesta al aire o ambiente salado, utilice una unidad exterior especialmente diseñada para resistir la corrosión. 77 INSTRUCCIONES DE INSTALACIÓN Paso 2: Instale la junta/unión de drenaje Antes de atornillar la unidad exterior en su lugar, instale la junta/unión de drenaje en la parte inferior de la unidad. Hay dos tipos de juntas de drenaje dependiendo del tipo de unidad. 1. Coloque la sello/tapón de goma en el extremo de la junta/unión del drenaje que se conectará a la unidad exterior. 2. Inserte la junta/unión de drenaje en el orificio de la base de la unidad. 3. Gire la junta de drenaje 90 ° hasta que encaje en su sitio mirando la parte frontal de la unidad. 4. Conecte una extensión de manguera de desagüe (no incluida) a la junta de drenaje para redirigir el agua de la unidad durante su operación en modo de calefacción. El orificio de la base de la junta/unión de drenaje se encuentra en la parte inferior de la unidad. Nota para Climas Fríos En climas fríos, asegúrese de que la manguera de desagüe esté lo más cerca posible a la posición vertical para favorecer el drenaje rápido del agua. Si el agua se drena muy lentamente puede congelarse dentro de la manguera de desagüe e inundar la unidad. 78 INSTRUCCIONES DE INSTALACIÓN Paso 3: Anclaje de la unidad exterior La unidad exterior se puede anclar al suelo o algún soporte montado en la pared. La siguiente es una lista de tamaños de unidad exterior y la distancia en pies para su montaje. Prepare la base de instalación de la unidad de acuerdo con las dimensiones e imágenes a continuación. Número de modelo DAS180DBAHWDB Diagrama de dimensiones de montaje de unidad Dimensiones de la unidad Distancia A (Anchura x Altura x Profundidad) (mm / pulg) 922x715x379 (36.3”x28.2”x14.9”) 540 (21.26”) Distancia B (mm / pulg) 350 (13.8”) ADVERTENCIA Al perforar el concreto, se debe usar protección ocular en todo momento. Si la unidad va a ser montada a nivel de piso, siga las siguientes instrucciones: 1. Marque las posiciones para cuatro pernos de expansión basándose en las dimensiones en el cuadro de medidas de montaje de la unidad. 2. Pre-perforar los orificios para los pernos de expansión. 3. Despeje el polvo de concreto de los orificios. 4. Coloque una tuerca en el extremo de cada perno de expansión. 5. Usando un martillo, golpee los pernos de expansión en los orificios previamente perforados. 6. Retire las tuercas de los pernos de expansión y coloque la unidad exterior sobre los pernos. 7. Coloque la arandela en cada perno de expansión y luego cambie las tuercas. 8. Utilizando una llave, apriete cada tuerca hasta que quede ajustada. Si la unidad va a montarse en la pared, siga las siguientes instrucciones: 1. Marque las posiciones de los orificios de los soportes según las dimensiones en el cuadro de dimensiones de montaje de la unidad. 2. Pre-perforar los orificios para los pernos de expansión. 3. Limpie el polvo de concreto de los orificios. 4. Coloque una arandela y una tuerca en el extremo de cada perno de expansión. 5. Usando un martillo, golpee los pernos de expansión a través de los orificios de los soportes de montaje, coloque los soportes de montaje en posición y golpee los pernos de expansión en la pared. 6. Compruebe que los soportes de montaje están nivelados. 7. Levante con cuidado la unidad y coloque las bases de montaje en los soportes. 8. Atornille firmemente la unidad a los soportes. Nota: Para reducir las vibraciones y el ruido de una unidad montada en la pared, instale la unidad con juntas/empaques de goma. 79 INSTRUCCIONES DE INSTALACIÓN Paso 4: Conecte los cables de señalización/control y de alimentación El bloque de conexiones terminales de las unidades exteriores está protegido por una cubierta para el cableado eléctrico en la parte lateral de la unidad. Un diagrama completo del cableado está impreso en el interior de la cubierta del cableado. Área mínima transversal Tipos de cables: de los cables de • Cable de alimentación interior (según corresponda): H05V-F o H05V2-F alimentación y de señal • Cable de alimentación exterior: H07RN-F Amperios (A) AWG • Cable de señal: H07RN-F 10 18 ADVERTENCIA 13 16 Todo el cableado debe realizarse de acuerdo con el diagrama de 18 14 cableado que se encuentra en el interior de la cubierta de cableado de la unidad exterior. No mezcle cables con corriente “vivos” y nulos. 25 12 Esto es peligroso y puede causar un mal funcionamiento del aparato. 30 10 1. Prepare el cable para la conexión: a. Usando la herramienta para pelar cables (wire stripper), desmonte la cubierta de plástico de ambos extremos del cable de señalización hasta pelar unos 40 mm (1,57 in) del interior del cable. b. Tire el aislamiento de los extremos de los cables. c. Usando una herramienta para prensar terminales cable (Wire crimper Tool) , prense las terminales tipo “u “en los extremos de los cables. Nota: Preste atención al cable con corriente “vivo”. Mientras prense los alambres, asegúrese de distinguir el alambre con corriente –vivo- (“L”) y los otros cables. 2. Desatornille la cubierta del cableado eléctrico y retírela. 3. Desatornille la abrazadera de cable debajo del bloque de terminales y colóquela a un lado. 4. Haga coincidir los colores y las etiquetas de los cables con las etiquetas en el bloque de terminales y atornille firmemente la u-lug de cada cable a su terminal correspondiente. 5. Después de verificar para asegurarse de que cada conexión es segura, haga un lazo alrededor de los cables para evitar que el agua de lluvia fluya hacia el terminal. 6. Con la abrazadera del cable, sujete el cable a la unidad. Atornille firmemente la abrazadera del cable. 7. Aísle los cables no utilizados con cinta aislante de PVC. Organizarlos para que no toquen ninguna parte eléctrica o de metal. 8. Vuelva a colocar la cubierta del cable en el lado lateral de la unidad y atorníllela en su lugar. El diagrama de cableado se encuentra en el interior de la cubierta del cableado de la unidad exterior 80 INSTRUCCIONES DE INSTALACIÓN CONEXIÓN DE TUBERÍA DEL REFRIGERANTE La longitud de la tubería del refrigerante afectará el rendimiento y la eficiencia energética de la unidad. La eficiencia nominal es probada en unidades con una longitud de tubería de 5 m (16,5 pies). INSTRUCCIONES DE CONEXIÓN - TUBERÍA DEL REFRIGERANTE Paso 1: Corte las tuberías Cuando prepare tuberías del refrigerante, tenga mucho cuidado en cortarlas y ensancharlas adecuadamente (mediante herramienta para ensanchar tubería – Tube Flaring Tool de su nombre en Ingles) . Esto garantizará un funcionamiento eficiente y minimizará la necesidad de mantenimiento futuro. 1. Mida la distancia entre las unidades interior y exterior. 2. Utilizando una herramienta para cortar de tubería, corte el tubo un poco más largo que la distancia medida. 3. Asegurarse de que la tubería se corte a 90 °. Nota: No dañar, doblar o deformar el tubo mientras se corta. Esto reducirá drásticamente la eficiencia de calentamiento de la unidad. Paso 2: Retirar las rebabas (residuos de metal) Las rebabas pueden afectar el sellado hermético de la conexión de la tubería del refrigerante. Las rebabas deben ser eliminadas por completo. 1. Sujete el tubo en un ángulo hacia abajo para evitar que las rebabas caigan en el tubo. 2. Utilizando un escariador o herramienta para eliminar rebaba, quite todas las rebabas de la sección cortada del tubo. 81 INSTRUCCIONES DE INSTALACIÓN Paso 3: Ensanche los extremos de la tubería (puntas de la tubería) El ensanchamiento adecuado es esencial para lograr un sello hermético. 1. Después de eliminar las rebabas de la tubería que se corto, sellar los extremos con cinta de PVC para evitar que los materiales extraños entren en la tubería. 2. Envuelva el tubo con material aislante. 3. Coloque las tuercas cónicas en ambos extremos del tubo. Asegúrese de que están mirando en la dirección correcta, ya que no se pueden quitar o ajustar después de la tubería se ha ensanchado. 4. Retire la cinta de PVC de los extremos de la tubería cuando esté lista para realizar trabajos de ensanchado. 5. Abra la abrazadera en el extremo de la tubería. El extremo del tubo debe extenderse más allá del borde de la forma ensanchada de acuerdo con las dimensiones mostradas en la tabla y la imagen de abajo. EXTENSIÓN DE TUBERÍA MÁS ALLÁ DEL FORMULARIO FLARE Diámetro exterior del tubo (mm) Dimensión A Mínima (mm) Dimensión A Máximo (mm) Ø 6.35 (Ø 0.25 pulgada) 0.7 (0.0275 pulgada) 1.3 (0.05 pulgada) Ø 9.52 (Ø 0.375 pulgada) 1.0 (0.04 pulgada) 1.6 (0.063 pulgada) Ø 12.7 (Ø 0.5 pulgada) 1.0 (0.04 pulgada) 1.8 (0.07 pulgada) Ø 16 (Ø 0.63 pulgada) 2.0 (0.078 pulgada) 2.2 (0.086 pulgada) 6. Coloque en el lugar la herramienta de ensanchamiento de tubería. 7. Gire el asa de la herramienta de ensanchamiento en el sentido de las agujas del reloj hasta que el tubo esté completamente ensanchado 8. Retire la herramienta de ensanchamiento de tubería, a continuación, inspeccione el extremo de la tubería para comprobar si hay grietas e incluso si se realizo un ensanchamiento uniforme. 82 INSTRUCCIONES DE INSTALACIÓN Paso 4: Conecte las tuberías Al conectar tuberías de refrigerante, tenga cuidado de no utilizar un fuerza o torsión en exceso, ni deformar la tubería de ninguna manera. Conecte primero el tubo de baja presión y después conecte el tubo de alta presión. Nota: Cuando dobla la conexión de tubería del refrigerante, el radio de curvatura mínimo es de 10 cm (3.9 in). CONEXIÓN DE LA TUBERÍA A LA UNIDAD INTERIOR 1. Alinee el centro de los dos tubos que se conectarán. 2. Apriete la tuerca cónica tan firmemente como sea posible con la mano. 3. Con una llave, sujete la tuerca en el tubo de la unidad. 4. Mientras sujeta firmemente la tuerca en el tubo de la unidad, utilice una llave de torsión para apretar la tuerca cónica de acuerdo con los valores de torsión en la tabla de requerimientos de torsión que se dan a continuación. Afloje ligeramente la tuerca cónica y luego apriete de nuevo. Una fuerza excesiva puede romper la tuerca o dañar la tubería del refrigerante. No exceder los requerimientos de torsión que se muestran en la siguiente tabla. Diámetro exterior del tubo (mm) Ø 6.35 (Ø 0.25 in) Ø 9.52 (Ø 0.375 in) Ø 12.7 (Ø 0.5 in) Ø 16 (Ø 0.63 in) REQUISITOS DE TORQUE Pares de apriete (N•cm) 1,500 (11 lb•ft) 2,500 (18.4 lb•ft) 3,500 (25.8 lb•ft) 4,500 (19 lb•ft) 83 Pares de apriete adicionales (N•m) 1,600 (11.8 lb•ft) 2,600 (19.18 lb•ft) 3,600 (26.55 lb•ft) 4,700 (34.67 lb•ft) INSTRUCCIONES DE INSTALACIÓN CONEXIÓN DE LA TUBERÍA A LA UNIDAD EXTERIOR 1. Desatornille la tapa de la válvula empaquetada en un lado de la unidad exterior. 2. Retire las tapas protectoras de los extremos de las válvulas. 3. Alinee el extremo del tubo ensanchado con cada válvula y apriete la tuerca cónica tan firmemente como sea posible con la mano. 4. Con una llave, sujete el cuerpo de la válvula. No agarre la tuerca que sella la válvula de servicio. 5. Mientras sujeta firmemente el cuerpo de la válvula, utilice una llave de torsión para apretar la tuerca cónica de acuerdo con los valores de tosían correctos. 6. Afloje ligeramente la tuerca cónica y vuelva a apretarla de nuevo. 7. Repita los pasos 3 a 6 para el tubo restante. 84 INSTRUCCIONES DE INSTALACIÓN EXTRACCION/PURGA DEL AIRE Preparaciones y Precauciones El aire, humedad y materias extrañas en el sistema de refrigeración pueden causar aumentos anormales en la presión, lo que puede dañar el aire acondicionado, reducir su eficiencia y causar lesiones. Utilice una bomba de vacío y un manómetro de colector para purgar el sistema de refrigeración, eliminando cualquier gas no condensable (Aire) y la humedad del sistema. La extracción/purga debe realizarse durante la instalación inicial y cuando la unidad sea transportada o trasladada. Antes de realizar la extracción/purga: • Compruebe que tanto la tubería de alta presión como la de baja presión entre las unidades interior y exterior estén correctamente instaladas. • Compruebe que todos los cables estén conectados correctamente. Instrucciones de evacuación Antes de utilizar el juego de manómetros y la bomba de vacío, lea sus manuales de operación para asegurarse de que se están usando correctamente. 85 INSTRUCCIONES DE INSTALACIÓN Instrucciones de extracción/purga 1. Conecte la manguera de carga del manómetro al puerto de servicio de la válvula de baja presión localizado en la unidad exterior. 2. Conecte otra manguera de carga del manómetro a la bomba de vacío. 3. Abra el lado de baja presión del manómetro múltiple. Mantenga el lado de alta presión cerrado. 4. Encienda la bomba de vacío para purgar el sistema. 5. Deje en operación la bomba de vacío durante al menos 15 minutos o hasta que el medidor compuesto lea -76cmHG (-105 Pa). 6. Cierre el lado de baja presión del manómetro múltiple y apague la bomba de vacío. 7. Espere 5 minutos y verifique que no ha habido cambios en la presión del sistema. 8. Si hay un cambio en la presión del sistema, consulte la sección Comprobación de fugas de gas para obtener información sobre cómo verificar si el sistema tiene fugas. Si no hay ningún cambio en la presión del sistema, desenrosque la tapa de la válvula de alta presión empaquetada. 9. Inserte la llave hexagonal en la válvula de alta presión empacada y abra la válvula girando la llave en un giro de 1/4 en el sentido de las agujas del reloj. Escuche cuando el gas sale del sistema, luego cierre la válvula después de 5 segundos. 10. Observe el indicador de presión durante 1 minuto para asegurarse de que no hay cambio en la presión. La lectura en el manómetro debería ser un poco más alto que la presión atmosférica. 11. Retire la manguera de carga del puerto de servicio. 12. Con una llave hexagonal, abra completamente ambas válvulas de alta presión y baja presión. 13. Apriete manualmente las tapas de las válvulas en las tres válvulas (puerto de servicio, alta presión y baja presión). Apriete con una llave de torsión en caso de ser necesario. ADVERTENCIA CUIDADO DE NO MEZCLAR DIFERENTES TIPOS DE REFRIGERANTES 86 INSTRUCCIONES DE INSTALACIÓN Nota: Abra despacio el vástago de la válvula. Para abrir los vástagos de la válvula, gire la llave hexagonal hasta que golpee contra el tope. No intente forzar la válvula a abrirse mas de lo debido. Nota: Algunos sistemas requieren una carga adicional dependiendo de las longitudes de tubería. La longitud estándar de la tubería varía según las regulaciones locales. Por ejemplo, en Norteamérica, la longitud estándar del tubo es de 7,5 m (25 pies). En otras áreas, la longitud estándar del tubo es de 5 m (16 pies). El refrigerante adicional que debe cargarse se puede calcular utilizando la fórmula del siguiente gráfico. Refrigerante adicional por longitud de tubo Longitud de tubo Método de conectivo (m) purga de aire < Longitud de Bomba tubería estándar aspiradora Refrigerante adicional N/A Lado líquido: Ø 6.35 (ø 0.25 in) > Longitud de tubería estándar Bomba aspiradora Lado líquido: Ø 9.52 (ø 0.375 in) Inversor R410a: Inversor R410a: (Longitud del tubo - LTE) x 15g/m (Longitud del tubo - LTE) x 30g/m (Longitud del tubo - LTE) x 0.16oZ/ft (Longitud del tubo - LTE) x 0.32oZ/ft LTE = Longitud de tubería estándar 87 INSTRUCCIONES DE INSTALACIÓN COMPROBACION ELÉCTRICA Y VERIFICACION DE FUGAS DE GAS Comprobaciones de seguridad eléctrica Después de la instalación, confirme que todos los cables eléctricos están instalados de acuerdo con las regulaciones locales / nacionales y de acuerdo con el manual de instalación. Verificación del trabajo de puesta a tierra Antes de completar una prueba, mida la resistencia a tierra mediante detección visual y con un comprobador de resistencia a tierra. La resistencia de puesta a tierra debe ser inferior a 4. Verificación de fugas eléctricas Durante la prueba, utilice un probador eléctrico y un multímetro para realizar una prueba exhaustiva de fuga eléctrica. Si se detecta una fuga eléctrica, apague la unidad inmediatamente y llame a un electricista certificado para encontrar y resolver la causa de la fuga. ADVERTENCIA All wiring must comply with local and national electrical codes and must be installed by a licensed electrician. Verificación de Fugas de Gas Existen dos métodos aceptables para verificar fugas de gas. Método de jabón y agua Con un cepillo suave o esponja, aplique agua jabonosa o detergente líquido a todos los puntos de conexión de tubería, tanto en las unidad interior y exterior. La presencia de burbujas será una indicación una fuga. Método del detector de fugas Si utiliza un detector de fugas, consulte el manual de operación del dispositivo para obtener las instrucciones de uso adecuadas. Nota: Después de completar las verificaciones de fugas de gas, confirme que no hay fugas en todos los puntos de conexión de la tubería y asegúrese de reemplazar la cubierta de las válvulas en la unidad exterior. 88 INSTRUCCIONES DE INSTALACIÓN PRUEBA DE FUNCIONAMIENTO Antes de completar una prueba funcionamiento, asegúrese de completar todas las comprobaciones de seguridad eléctrica y verificación de fugas de gas. Confirme que el sistema eléctrico de la unidad es seguro y funciona correctamente. Compruebe todas las conexiones en tubería con tuerca cónica y confirme que el sistema no tiene fugas. Instrucciones para la prueba de funcionamiento 1. Conecte la alimentación eléctrica a la unidad. 2. Presione el botón ON / OFF del mando a distancia (Control Remoto) para encender la unidad. 3. Pulse el botón MODE para desplazarse por las siguientes funciones: • COOL - seleccione la temperatura más baja posible • HEAT - seleccione la temperatura más alta posible 4. Permita que cada función funcione durante 5 minutos y realice las siguientes comprobaciones: • • • • • • • • • • • No hay fugas eléctricas La unidad está debidamente conectada a tierra Todos los terminales eléctricos están debidamente cubiertos La unidad interior y exterior están bien instaladas y aseguradas. Todos los puntos de conexión de la tubería no presentan fugas, El agua drena correctamente por la manguera de desagüe Toda la tubería está correctamente aislada (uso de aislante) La unidad realiza correctamente la función COOL (FRIO) La unidad realiza correctamente la función HEAT (CALOR) Las rejillas de la unidad interior giran correctamente La unidad interior responde al mando a distancia (Control Remoto) IMPORTANTE: Durante el funcionamiento, la presión del sistema refrigerante aumentará. Esto puede revelar fugas que no estuvieron presentes durante la verificación inicial de fugas. Tome tiempo durante la prueba de funcionamiento, para verificar que todos los puntos de conexión de la tubería del refrigerante no tengan fugas. 5. Una vez terminada la prueba de funcionamiento, utilice el mando a distancia (Control Remoto) para volver a la temperatura normal de funcionamiento. Usando cinta aislante, envuelva las conexiones de la tubería del refrigerante en la unidad que quedaron sin cubrir durante el proceso de instalación de la unidad interior. Prueba de funcionamiento a baja temperatura Si la temperatura ambiente es inferior a 17 °C (62.6 °F), la función COOL no funcionará cuando se utiliza el mando a distancia (Control Remoto). En este caso, utilice el botón de control manual para probar la función COOL. 1. 1. Levante el panel frontal de la unidad interior y levántelo hasta que encaje en su lugar. 2. 2. El botón de control manual se encuentra en el lado derecho de la unidad. Pulse dos veces para seleccionar la función COOL. 3. 3. Lleve a cabo la prueba de funcionamiento de manera normal. Directrices para la eliminación Este aparato contiene refrigerante y otros materiales potencialmente peligrosos. Al deshacerse de este aparato, la ley requiere una recogida y tratamiento especiales. No deseche este electrodoméstico como basura doméstica o residuos municipales no clasificados. 89 LIMITED IN-HOME APPLIANCE WARRANTY GARANTÍA LIMITADA DEL APARATO This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. Este producto de calidad está garantizado contra defectos de fabricación, incluyendo partes y mano de obra, siempre y This warranty is availablese onlyutilice to the person whom the unit was originally sold by de Danby Products Limited (Canada) Danby Inc. (U.S.A.) (hereafter cuando la unidad bajotolas condiciones normales funcionamiento paraorlas que fue Products diseñado. “Danby”) or by an authorized distributor of Danby, and is non-transferable. Esta garantía está solamente disponible para la persona que haya comprado originalmente esta unidad directamente de Danby Products Limited (Canada) o Danby Products Inc. (U.S.A.) (en adelante “Danby”) o uno de sus distribuidores autorizados, y no es transferible. TERMS OF WARRANTY Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided. CONDICIONES DE LA GARANTÍA Las piezas plásticas, se autorizan por treinta (30) días solamente a partir de la fecha de la compra, sin las extensiones First Year During the first twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s proporcionadas. option, at no charge to the ORIGINAL purchaser. Primeros 24 meses Durante los primeros veinticuatro (24) meses, cualquier parte en buen estado de este producto que To obtain Danby reserves the right to limitincluyendo the boundaries cualquier of “In Home Service” to thesellado, proximity ofserá an Authorized ServiceoDepot. Any app resulte defectuosa, sistema reparado reemplazado, aliance opción Service requiring service outside the limited boundaries of “In Home Service” , i t will be the consumer’s responsibility to transport the appliance (at del fabricante, sin cargo para el comprador ORIGINAL. their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below. Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service mustgarantía be performed by a qualified technician. Nada dentro de esta implica queservice Danby será responsable por cualquier daño que hayan sufrido los alimentos If service performed onya the sea units by anyone other an authorized service depot,oorsu the uso, unit is used for commercial appli cation, all u otros contenidos de esteis aparato, debido a unthan defecto del aparato, adecuado o inadecuado. obligations of Danby under this warranty shall be void. EXCLUSIONES Boundaries of If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be Salvo lo aquí indicado por Danby, no existen otras garantías, condiciones o representaciones, explícitas o implícitas, In Home Service delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualified and certif ied for concretas o intencionales por parte deTransportation Danby o charges sus distribuidores autorizados todas las demás condiwarranty service by Danby. to and from the service location are noty protected by this warrantygarantías, and are t he ciones o representaciones, cualquier garantía, condiciones o representaciones bajo cualquier Acta de Venta responsibilityincluyendo of the purchaser. de Productos o legislación o estatuto similar, quedan de esta forma expresamente excluidas. Salvo lo aquí indicado, Danby no serán responsables ningún daño a orpersonas bienes, incluyendo propia unidad, importar sudue Nothing within this warranty shall imply thatpor Danby will be responsible liable for anyospoilage or damage to food orla other c ontents of thissin appliance, whether causa, o de ningún daño indirecto to any defect of the appliance, or its use, whether proper or improper. causado por el desperfecto de la unidad, y al comprar esta unidad, el comprador acepta por la presente, indemnizar y proteger a Danby contra cualquier reclamo por daños EXCLUSIONS a personas o bienes causados por la unidad. Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its CONDICIONES authorized distributors and all other warranties, conditions, representations or guarantees,GENERALES including any warranties, conditio ns, representations or guarantees No seany considerará de estas garantías o seguros cuando el daño o la necesidad producto under Sale of Goods Actninguna or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no de reparación t be responsiblesea for anyeldamages de los siguientes to persons or property, casos: including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit. 1) Falla del suministro eléctrico. 2) Daños en tránsito o durante el transporte de la unidad. GENERAL PROVISIONS 3) Alimentación incorrecta, como bajo voltaje, instalación eléctrica defectuosa o fusibles inadecuados. 4)NoAccidente, modificación, abuso o uso incorrecto del orartefacto, talbycomo insuficiente warranty or insurance herein contained or set out shall apply when damage repair is caused any of the following: ventilación del ambiente o condiciones operación anormales (temperatura ambiente extremadamente alta o baja). 1) Powerde failure. 5) Utilización comercial o industrial (v.g., si el electrodoméstico no está instalado en una vivienda particular). 2) Damage in transitpor or when moving the appliance. 6) Incendio, daños agua, robo, guerra, disturbios, hostilidades, actos de fuerza mayor como huracanes, inundaciones, 3) etc. Improper power supply such as low voltage, defective house wiring or inadequate fuses. 7) Pedidos de servicio debido a desinformación usuario. 4) Accident, alteration, abuse or misuse of the appliance such del as inadequate air circulation in the room or abnormal operating con ditions 8) Instalación inadecuada (v.g., instalación empotrada de un electrodoméstico diseñado como unidad independiente o (extremely high or low room temperature). uso de un electrodoméstico al aire libre que no esté aprobado para dicho fin). 5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence). Fire, water theft, war, hostility, actsunof God such as hurricanes, etc. por lo tanto, guarde su recibo. Para 6) acceder a damage, la garantía seriot, solicitará comprobante defloods compra; 7) Service calls resulting in customer education. 8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application). Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our AUTHORIZED SERVICE DEPOT. Warranty Service In-home Danby Products Limited Danby Products PO Box 1778, Guelph,Limited Ontario, Canada N1H 6Z9 PO Box 1778, Guelph,FAX: Ontario, Canada N1H 6Z9 Telephone: (519) 837-0920 (519) 837-0449 Telephone: (519) 837-0920 FAX: (519) 837-0449 1-800-263-2629 1-800-263-2629 12/19 04/09 Danby Products Inc. Danby Inc. PO Box 669, Findlay, Ohio, U.S.A. Products 45840 PO Box 669, Ohio, Telephone: (419) Findlay, 425-8627 FAX: (419)U.S.A. 425-8629 45840 Telephone: (419) 425-8627 FAX: (419) 425-8629 MODEL • MODÈLE • MODELO DAS090BAHWDB DAS120BAHWDB DAS180BAHWDB DAS240BAHWDB Printed in China Imprimé en Chine Impreso en China Danby Products Limited, Guelph, ON, Canada N1H 6Z9 Danby Products Inc., Findlay, Ohio, USA 45840
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Danby DAS180DBAHWDB El manual del propietario

Categoría
Acondicionadores de aire de sistema dividido
Tipo
El manual del propietario