SCAN 1010 Series Assembly And Instruction Manual

Categoría
Estufas
Tipo
Assembly And Instruction Manual
SCAN A/S - DK-5492 VISSENBJERG
Scan 1010 Series
Congratulations on your new Scan wood-burning stove
You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of pleasure
with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Please read this Assembly- and instructions manual before you start to assemble your stove.
Product registration number
Please indicate the product registration number at any enquiry
ASSEMBLY- AND INSTRUCTIONS MANUAL
UK
2
Table of contents
Technical data ........................................................................................................ 3
Installation
Safety
Technical data and dimensions
Dimension sketch
Type plate
Product registration number
Additional accessories
Loose parts
Assembly .................................................................................................................. 8
Remove packaging
Positioning your wood-burning stove
Load bearing foundation
Distances to combustible floor.
Distance to furniture
Radiance distance to combustible objects
Distances to combustible floor.
Storage of flammable material
Carrying capacity
Distance to flammable materials, shown with insulated flue pipe
Distance to flammable materials, shown with un-insulated flue pipe
Distance to firewall
Mounting with plinth
Mounting of the wall bracket
Burn chamber
Existing chimney and pre-fabricated element chimney
Connection between stove and steel chimney
Requirements for chimney
Connection with 90° elbow pipe
Fresh air intake
Closed combustion system
Instruction for use ............................................................................................. 20
CB technique
Primary air
Secondary air
Baffle plates
Indicator for control of air supply
Instructions for heating ................................................................................... 21
Lighting
Handling fuel
Maintenance ........................................................................................................ 23
Troubleshooting .................................................................................................. 24
Defra ....................................................................................................................... 25
CONTENTS
3
Installation
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Our Scan Dealer will be able to
recommend a qualified fitter in your area. For information on Scan Dealers, please go to http://scan.dk.
When you install any kind of fireplace or stove, you must inform the local authorities. You are also responsible for calling in a chimney sweep to
inspect and authorize the installation.
The house owner is responsible for ensuring that all necessary national, European and local safety measures are observed during installation and
fitting and also responsible for observing the fitting and operating instructions detailed in this manual.
Safety
Any changes made to the product by the dealer, installer or user could result in the product and safety functions not functioning as intended. The
same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary
for the operation and safety of the stove are dismantled or removed.
WARNING
This product contains very strong magnets.
When separating and putting together the magnets, we recommend that you let them glide on (or from) one another. In this way you avoid
squeezing your fingers and damaging the coating of the magnets.
Electronic components should be kept at a safe distance from the magnets to avoid them being influenced or damaged by the magnetic field
(pacemakers, hearing aids, computers, watches, measuring instruments, floppy discs, credit cards, mobile phones etc.).
TECHNICAL DATA
4
Test in compliance with EN 13229
Scan 1010 Technical data Unit
CO Emission at 13% O
2
0,1 %
CO Emission at 13% O
2
1246 mg/Nm
3
Dust @ 13% O
2
12 mg/Nm
3
No
x
@ 13% O
2
41 mg/Nm
3
Efficiency 82 %
Energy efficiency index
109,9
Energy efficiency class
A+
Nominel output 7 kW
Chimney temperature EN 13229 220 °C
Temperature in connecting piece 264 °C
Amount of smoke 7,4 g/sek
Sub-pressure EN 13229 12 Pa
Recommended sub-pressure in connecting piece 16 - 18 Pa
Required combustion air supply 19,8 Nm
3
/h
Fuel Wood
Fuel consumption 2,2 kg/h
Amount of fuel 1,7 kg
Technical data and dimensions
Materials: ................................ Steel plate, galvanised sheet,
Vermicolite, Chamotte, Robax glass
Surface treatment: .......................................................................... Senotherm
Max. wood length: ..................................................................................... 50 cm
Weight Scan 1010: .....................................................................approx 135 kg
Weight big box:...............................................................................approx 32 kg
Weight little box:............................................................................approx 20 kg
Connecting piece internal diameter: .............................................. 144 mm
Connecting piece external diameter: .............................................. 148
mm
Approval type: ................................................................ Intermittent fuelling
Intermittent fuelling means normal use of a woodstove. In other
words, you should let the fire die down until only the embers are left,
before refuelling.
The Scan 1010 was build in compliance with the homologized product
type specified in the Assembly- and Instructions Manual provided
with the product.
The DoP declaration of performance is available from scan.dk
Please note:
You get the best use of the stove by using a
”top-down lighting”, see page 21.
TECHNICAL DATA
5
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010005.idw
91010005
målskitse Scan 1010
13-04-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
479
649
324,5 D
5
7
2
143 D
9
3
F
9
9
,
5
A
5
6
4
,
5
C
799
399 B
5
7
2
5
6
5
C
399 D
1
8
8
B
2
9
1
B
324,5 B
5
TECHNICAL DATA
Dimension sketch Scan 1010
A Centre rear outlet
B Top outlet
C Height to the beginning of the
connecting piece at top outlet
D Centre of fresh air intake bottom
F Fresh air intake at the back of the stove
6
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010008.idw
91010008
Mål ovn, base, sokkel
20-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
1
0
5
7
2
2
8
1
1
0
9
9
7
2
649
324,5 B
1
8
8
B
2
9
1
B
2
5
0
F
4
9
3
F
8
7
3
A
479
9
6
5
C
324,5 D
143 D
TECHNICAL DATA
Dimension sketch Scan 1010
A Centre rear outlet
B Top outlet
C Height to the beginning of the
connecting piece at top outlet
D Centre of fresh air intake bottom
F Fresh air intake at the back of the stove
4
7
9
6
4
9
2
8
1
4
1
1
3
1
9
109
6
4
9
4
1
1
109
4
7
9
6
4
9
2
8
1
4
7
9
2
8
1
3
1
9
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010034.idw
91010034
vægbeslag løse
12-08-2016
mbp
Scan 1010
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010033.idw
91010033
Friskluft skjuler
12-08-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
7
TECHNINIAI DUOMENYS
TECHNICAL DATA
Large wall bracket
Small wall bracket
Large module
- is not to be
used under the
stove!
Small module
Cover for
fresh air inlet
Large module
with fresh air
inlet and heat
shield.
Large plinth
Small plinth
Additional accessories
8
XX00000
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010003.idw
91010003
Ovn bag
23-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010010.idw
91010010
indpakning
24-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
Scan 1010
Freestanding room heater fired by solid fuel
Standard:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 91010600
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
15a B-VG
Certificate/Standard
EN 13240
300-ELAB-1588-NS
300-ELAB-1588-AUS
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³
Flue gas temperature: 220°C
Nominal heat output: 7 kW
Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials:
Side: 500 mm - Back: 150 mm - Front: 1400 mm
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 08-2017
0,10% 1246 mg/Nm³
Schweiz
Germany
LRV 11
Stufe 2
VKF
1. BlmSchV
Teknologisk Institut
Teknologisk Institut
TECHNICAL DATA/ASSEMBLY
Type plates
All Scan wood-burning stoves are fitted with a type plate, that speci-
fies the approval standards and the distance to flammable materials.
The type plate is located at the back of the stove.
Product registration number
All wood-burning stoves are provided with a product registration
number.
The product registration number is located at the back of the stove.
Please make a note of this number on the front page as you will
always have to state it when contacting your dealer or Scan A/S.
Type plate
Product
registration
number
Loose parts
Glove
Connecting piece
Gasket for connecting piece
Screws for connecting piece 5 x 12 mm
Connecting piece for fresh air inlet
Screws for connecting piece/fresh air 4 x 10 mm
Decor ring for top outlet
• Screw M5x6 (UK)
Additional accessories
Large/small module
Large/small plinth
Large/small wall bracket
Protection glass for large/small module
Magnets
Cover for fresh air inlet
Small floor plate (glass or steel)
Large floor plate (glass or steel)
Disposal of packaging
Your Scan stove may come supplied with the following packaging:
Wood packaging:
The wood packaging can be reused and after final use can be incine-
rated as a CO2 neutral product or sent for recycling.
Flamingotop:
Send for recycling or waste disposal.
Foam:
Send for recycling or waste disposal.
Plastic bags:
Send for recycling or waste disposal.
Stretch film/plastic film:
Send for recycling or waste disposal.
9
Scan 1010
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064049.idw
90064049
Brændbar + uisoleret røgrør - Scan 64 uden sideglas
23-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
150
350
340
595
100
363
628
100
3
2
4
Min. 400 mm
Min. 1400 mm
Min.
140 mm
Min.
140 mm
Positioning your wood-burning stove
The wood-burning stove must be set up so that the stove itself, the
flue pipe, and the chimney can all be cleaned.
Load bearing underlay
All of the products in our portfolio are classified as light-duty firepla-
ces; in most cases, there is no need to reinforce the floor, so that you
can typically use the normal floor.
However, you should make sure that the load bearing underlay can
bear the weight of the wood-burning stove and that of the chimney.
Distance to furniture: 1400 mm
But please check to avoid furniture or other furnishings being dried
out due to being too close to the stove.
All national and local requirements concerning safety distances for
wood burning stoves must be respected.
If you connect the stove to a steel chimney, the safety distances of
the steel chimney must also be respected.
Radiance distance to combustible objects out-
side the modules.
Distances to combustible floor.
Remember to place a floor plate.
ASSEMBLY
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010013.idw
91010013
opbevaring af brænde
30-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
10
Max
MAX
* * *
*
*
* *
*
*
*
*
* *
** *
*
*
= 10 mm
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010043.idw
91010043
moduler
16-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
Max
MAX
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010043.idw
91010043
moduler
16-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
285 285
KGKG
Storage of flammable material
You can store wood under
the stove in the module
with heat shield and fresh
air inlet.
ASSEMBLY
Carrying capacity
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064049.idw
90064049
Brændbar + uisoleret røgrør - Scan 64 uden sideglas
23-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
150
350
340
595
100
363
628
100
3
2
4
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064049.idw
90064049
Brændbar + uisoleret røgrør - Scan 64 uden sideglas
23-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
150
350
340
595
100
363
628
100
3
2
4
50
50
50
50
500
400
150
50
11
Distance to flammable materials, shown with insulated flue pipe*
Distance to flammable materials, shown with un-insulated flue pipe*
The distances presuppose the use of an insulated flue pipe with min. 30 insulation all the way to the stove.
Parallel rear wall installation
Parallel rear wall installation
45° Corner installation
45° Corner installation
ASSEMBLY
Scan 1010
Scan 1010
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010051.idw
91010051
Scan 1010 - Montage røgstuds i topafgang
12-02-2018
ken
Scan 1010
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064047.iam
90064047
Brandmur og isoleret røgrør - Scan 64 uden sideglas
29-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
50
50
100
50
50
700
700
960
700
700
2
53
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064047.iam
90064047
Brandmur og isoleret røgrør - Scan 64 uden sideglas
29-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
50
50
100
50
50
700
700
960
700
700
2
53
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064047.iam
90064047
Brandmur og isoleret røgrør - Scan 64 uden sideglas
29-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
50
50
100
50
50
700
700
960
700
700
2
53
1000
1000
1000
0
0
0
12
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 64\90064047.iam
90064047
Brandmur og isoleret røgrør - Scan 64 uden sideglas
29-08-12
BC
Scan 64
VÆGT:
AREAL:
N/A
N/A
50
50
100
50
50
700
700
960
700
700
2
53
350
1000
0
1000
300
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010051.idw
91010051
Scan 1010 - Montage røgstuds i topafgang
12-02-2018
ken
Scan 1010
VÆGT:
AREAL:
N/A
N/A
A
C
D
B
Distance to firewall*
110 mm brick or other material with a corresponding insulation ability.
The indicated distances are valid for insulated as well as un-insulated smoke pipes.
Flammable material
Firewall
ASSEMBLY
* All national and local requirements concerning safety distances for wood burning stoves must be respected.
Scan 1010
Connecting piece
The insert is prepared for a top flue outlet from the factory.
The flue connection piece (A), gasket for the flue connection piece (B), screws (C) and cover ring (D)
can be found in the stove’s combustion chamber.
13
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010018.idw
91010018
expl. tegning
08-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010019.idw
91010019
Emb afbræk
10-06-2016
hms
Scan 1010
VÆGT:
AREAL:
0,04 kg
20656 mm^2
DIM.:
Scan A/S
A
A
A
B
C
D
D
E
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010014.idw
91010014
sokkel magnet
31-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010015.idw
91010015
justering af sokkel
08-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
A ( 0,40 : 1 )
A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010039.idw
91010039
indstil ben
23-08-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
1.
3.
2.
First mount the module with fresh air inlet on the plinth and then the stove. Place the magnets on the
next modules before mounting them.
Please follow the order below A, B, C, D, and E.
It is important to adjust the plinths before mounting the modules.
Press the two distance triangles out of the packing. These are used for the proper
mounting of the magnets. The magnets are to be found inside the plinth at the delivery.
Mounting with plinth
ASSEMBLY
ccc
14
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010020.idw
91010020
vægbeslag
13-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010029.idw
91010029
afmont. af dæksler
21-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010027.idw
91010027
Varmeskjold afmont.
20-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
Scan 1010 Wall
Wall mounted room heater fired by solid fuel
Standard:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 91010601
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
15a B-VG
Certificate/Standard
EN 13240
300-ELAB-1588-NS
300-ELAB-1588-AUS
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³
Flue gas temperature: 220°C
Nominal heat output: 7 kW
Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials:
Side: 500 mm - Front: 1400 mm - Bottom: 400 mm
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 08-2017
0,10% 1246 mg/Nm³
Schweiz
Germany
LRV 11
Stufe 2
VKF
1. BlmSchV
Teknologisk Institut
Teknologisk Institut
Scan 1010 Wall
Wall mounted room heater fired by solid fuel
Standard:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 91010601
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
15a B-VG
Certificate/Standard
EN 13240
300-ELAB-1588-NS
300-ELAB-1588-AUS
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³
Flue gas temperature: 220°C
Nominal heat output: 7 kW
Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials:
Side: 500 mm - Front: 1400 mm - Bottom: 400 mm
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 08-2017
0,10% 1246 mg/Nm³
Schweiz
Germany
LRV 11
Stufe 2
VKF
1. BlmSchV
Teknologisk Institut
Teknologisk Institut
A
C
E
D
B
F
B
1.
2.
Scan 1010 Wall
Wall mounted room heater fired by solid fuel
Standard:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 91010601
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
15a B-VG
Certificate/Standard
EN 13240
300-ELAB-1588-NS
300-ELAB-1588-AUS
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³
Flue gas temperature: 220°C
Nominal heat output: 7 kW
Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials:
Side: 500 mm - Front: 1400 mm - Bottom: 400 mm
CO emission at 13% O2:
See assembly- and instructions manual
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000 08-2017
0,10% 1246 mg/Nm³
Schweiz
Germany
LRV 11
Stufe 2
VKF
1. BlmSchV
Teknologisk Institut
Teknologisk Institut
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010048.idw
91010048
røgstuds
06-10-2016
hms
Scan 1010
VÆGT:
AREAL:
0,61 kg
69343 mm^2
DIM.:
Scan A/S
Mounting of the wall bracket
First dismount the heat shield at the rear. The heat shield is not used on the wall model.
Pull the stove out of the module. Mount the fittings (A) at the top and the two adjustment fittings (B) at the bottom. If you want a rear outlet,
the cover plate (C) on the back of the stove must be removed and placed in the top outlet. Fit the connecting piece with the supplied gasket and
screws (D). The cover plate (E) at the rear of the module must also be removed. Place the type plate (F).
Mount the fittings in the same way on the other modules.
Is not to be
used on the wall
model.
Please note
that the delivered type plate must
be placed on the stove after dis-
mounting the heat shield.
ASSEMBLY
Content:
Small wall bracket + number plate
Content:
Large wall bracket + number plate
Place the delivered
type plate.
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010032.idw
91010032
Ophængs mål
08-08-16
jm
Scan 1010
VÆGT:
AREAL:
N/A
N/A
118,6
109
99,3
291
291
835
98,1
270
gulv
15
Min. 400 mm
Min. 874 mm
91± 2 mm
Wall-hung model
Installation must be planned and executed in accordance with natio-
nal and local building regulations.
The stove must only be fitted to a non-flammable wall. There must be
no form of flammable component in the wall. In the case of thin walls,
nor must there be any behind the wall. The load-bearing capacity of
the wall must be checked under all circumstances.
To ensure correct installation we recommend that a building expert
be commissioned to plan and outline the installation with a view to
subsequent approval.
For wall installation we recommend using the wall brackets supplied.
If a chimney is installed on top of a wall-hung model, the chimney
must be fully self-supporting. It must not rest on the wood-burning
stove. There must be a distance of at least 6 mm between the first
section and the flange on the flue collar. Please consult a specialist.
Scan A/S disclaims all liability for the installation of wall-hung
wood-burning stoves.
Dimensional drawings of the wall brackets
Combustible floor
ASSEMBLY
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010022.idw
91010022
opboring af beslag
14-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010031.idw
91010031
væg step by step
28-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
91±2
mm
1
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010030.idw
91010030
vægbeslag justering
28-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
3
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010023.idw
91010023
justerskive
14-06-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
2
4
A
B
C
16
A ( 1 : 2 )
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010045.idw
91010045
indikatorplade
19-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
A ( 1 : 2 )
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010045.idw
91010045
indikatorplade
19-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
The smoke pipe should be lead 9 1±2
mm out of the wall in order for it to
fit on the stove’s connecting piece.
See dimensional drawing.
1) Drill the holes with the drilling template (a)
2) Replace the drilling template (a) with the
adjustment template (b)
3) Can be adjusted up and down. Use a spirit level.
4) Mount the module (A) on the wall fitting.
Place the stove (B). Put on the indicator plate (C).
Mounting of the wall bracket
ASSEMBLY
17
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010042.idw
91010042
opstilling med knærør
25-08-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010046.idw
91010046
ovn med 90 gr røgrør
21-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1001\91001011.idw
91001011
Brændkammerforing, eksploderet
18-04-2012
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
Existing chimney and pre-fabricated element
chimney
If you intend to connect your stove to an existing chimney, it makes
sense to contact an authorised Scan dealer, or a local chimney sweep
for advice. These experts will also let you know if your flue needs
renovating.
When connecting a pre-fabricated element chimney, follow the
manufacturer’s connection instructions for the relevant chimney
type.
Connection between stove and steel chimney
Your Scan dealer, or local chimney sweep, can advise you on choosing
a make and type of steel chimney. This ensures that the chimney
will match your wood-burning stove. As a general rule, the length of
the flue should not be less than 3,5 m measured from the top of the
wood-burning stove.
Some weather or installation conditions might require another
length.
Choosing the wrong length or diameter of steel chimney could impair
functionality.
Always observe the chimney vendor‘s instructions precisely.
Requirements for chimney
The chimney must be labelled T400 and G for soot testing.
Connection with 90° elbow pipe
If you intend to use an elbow pipe with the Scan 1010 we recommend
the use of a curved elbow pipe to improve the draft.
If you are connecting your stove using a sharp elbow bend, the clea-
nout door should be in the vertical section, such that the horizontal
part can be cleaned through it.
Curved elbow pipe
Sharp elbow pipe
Baffle plate
in steel
Baffle plate
in vermicu-
lite
Combustion chamber lining
ASSEMBLY
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1001\91001041.idw
91001041
Nederste røgvenderplade
15-05-2012
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
B
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1001\91001041.idw
91001041
Nederste røgvenderplade
15-05-2012
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
18
1.
2.
3.
5.
6.
7.
8.4.
Place the bottom stones with the inclined edge
turning to the rear and downwards.
Place the log guard against the front of the
insert.
The rear burn chamber plates must be mounted
so that the holes of the plates are placed preci-
sely over the tertiary holes of the insert.
Mount the lower baffle plate. The baffle plate
must be supported by the rear plates.
Mount the pins and put
the plate in place.
Burn chamber
Note that the baffle plates are made of porous, ceramic material, and can break. Exercise care when working.
Mount the rear plates. The side plates keep the
rear plates in place, so that these do not fall over.
Mount the left burn chamber plate.
Mount the right burn chamber plate.
ASSEMBLY
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010038.idw
91010038
friskstuds bag
18-08-16
jm
Scan 1010
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010036.idw
91010036
Frisklfuft bund
18-08-16
jm
Scan 1010
VÆGT:
AREAL:
N/A
N/A
19
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010003.idw
91010003
Ovn bag
23-05-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010037.idw
91010037
dækplade friskluft
18-08-16
jm
Scan 1010
VÆGT:
AREAL:
N/A
N/A
Fresh air intake
In a well-insulated house, the air used up by the burning process has to
be replaced. This particularly applies to houses with mechanical ven-
tilation. There are different ways of making sure that an air exchange
takes place. The most important thing is to ensure that there is a sup-
ply of air to the room where the wood stove is located. The external
wall vent must be located as close to the wood stove as possible, and
you must be able to close it when you are not using the wood stove.
Beware that the valve in the outer wall cannot be covered by accident!
National and local building regulations must be followed with regard
to the connection of fresh-air intake.
Closed combustion system
You should use the closed combustion system for the wood-burning
stove if you live in a newly-built, airtight home. Outside air for com-
bustion is connected through a ventilation pipe via the wall or floor.
It must be possible to shut off the ventilation pipe with a valve, when
the stove is not in use.
Minimum Ø100 mm ventilation pipe, maximum length: 6 m with
a maximum of one bend
The connecting piece for external combustion air is to be found in the
packaging.
If the external combustion air is connected at the rear, the dis-
mounted plate must be mounted on the hole for external air in the
bottom of the stove.
NOTE: if the stove has a fresh air connexion or closed combustion,
the ventilation pipe must be open, when the stove is in use!
Mounting of external air supply
Dismount the cover plate behind or below the casette
Mount the Ø100 sleeve.
Mounting of external air supply
on the rear of the cassette.
Dismount the cover plate at the rear and mount it in the bottom.
Mounting of external air supply
on the bottom of the cassette.
Mount the Ø100 sleeve.
Ø100 sleeve
Ø100 sleeve
External combustion
air on the bottom of
the cassette
External air
supply on the
rear of the cas-
sette
ASSEMBLY
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010004.idw
91010004
CB teknik
18-03-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
20
0% - 100%
A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1010\91010047.idw
91010047
indikator luft
21-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
0% - 100%
Baffle plate
CB-technique
Primary air
Secondary air
Primary air
Log guard
Secondary air
Adjustment of air supply
CB-technique (Clean Burning)
The wood-burning stove is equipped with CB technology. In order
to ensure an optimal combustion of released gases under the inci-
neration process, air will pass through a specially developed canal
system. The heated air is led into the combustion chamber through
the small holes at the rear of the burn chamber. This airflow is driven
by the combustion rate and thus cannot be regulated.
Primary air
The primary air regulation mechanism is used for lighting the fire, or
to boost the burning process when you put wood on. The primary air
vent can be 0 - 30% open if you use hard wood fuel such as oak and
beech. You can close the primary air vent if you use soft wood such
as birch or pine for fuel.
Settings for normal load: 0 - 30%
Secondary air
Secondary air is pre-heated and fed indirectly to the fire. At the
same time, the secondary airflow cleans the glass pane to avoid soot
build-up. If you over-restrict the secondary airflow, soot can build up
on the glass pane. The secondary airflow determines the heat output
from your wood stove.
Settings for normal load: 50 - 70%
Baffle plates
The baffle plates are located in the upper part of the combustion
chamber. The plates hold back smoke, making sure it stays inside
the combustion chamber for a longer time before escaping through
the chimney. This reduces the smoke gas temperature as the gases
have more time to dissipate heat to the wood-burning stove. The
baffle plates must be removed for sweeping; see „Maintaining your
wood-burning stove“. Note that the baffle plates are made of porous,
ceramic material, and can break. Exercise care when working. The
baffle plates are subject to wear and tear, and are not covered by
the warranty.
INSTRUCTIONS FOR HEATING
ASSEMBLY
1.
2.
3.
4.
5.
21
Continuous firing
It is important to reach as high a temperature as possible in the
combustion chamber. This makes the most efficient use of the wood
stove and fuel, and ensures a clean burning process. At the same
time, this avoids soot build-up on the combustion chamber walls and
glass. While the stove is lit, you should not see any smoke, but just air
movement that indicates the burning process.
After completing the lighting phase, you should have a good layer of
embers in the wood stove; you can then start stoking up the stove.
Lay 1-3 pieces of wood, of about max 1,7 kg weight with max 10 cm
diameter and a length of about 25 cm onto the fire.
Note! The wood must catch fire quickly; this is why we recommend
setting the primary airflow to full power. Running the stove at too low
a temperature and with too little primary air can lead to deflagration
of the gases, and thus cause damage to the stove.
When stoking up with wood, always open the glass door carefully to
avoid smoke escaping. Never stoke up with wood while the fire is still
burning nicely.
Environmentally-Friendly Heating
Avoid restricting your wood-burning stove to an extent where no
flames are visible during the degasifying period, as this leads to
particularly inefficient heating. The gases released by the wood do
not burn due to the low temperature in the combustion chamber. Part
of the gas condenses in the wood-burning stove and flue system as
soot, and this could lead to your chimney catching fire. The smoke
that exits the chimney is bad for the environment and has an unple-
asant smell.
Lighting
We recommend the use of fire starters, or similar products, which are
available from your Scan dealer. Using fire starters helps to light the
wood quicker, and keeps the burning process clean.
Never use liquid lighting fuels!
"Top down" lighting
Important! Always use a top-down lighting. The stove is constructed
for this in order to give the best exploitation.
4 pieces of wood approx. 25 cm long with a weight of approx. 0.6 –
0.8 kg per piece (image 1)
The wood must not cover the bottom entirely and must never be pla-
ced higher than the Clean-Burn rail at the rear of the stove.
12 - 20 thin sticks of about 20 cm with a total weight of approx. 1,0-
1,2 kg (image 3 - 4). 4 fire starters (image 5).
Place logs, sticks and fire starters in the combustion chamber as
shown on images 1 - 5.
Set the primary and secondary airflow controls to maximum for
about 20 - 30 minutes. When the larger pieces of wood have caught
fire properly, you can set the primary and secondary airflow to the
desired level.
"Top down" lighting gives a more environmentally friendly start to
your fire and helps to keep the glass area as clean as possible.
INSTRUCTIONS FOR HEATING
22
INSTRUCTIONS FOR HEATING
Using your stove in the spring or autumn
In the transition period (spring/autumn), where there is less need for
heating, we recommend to make a single „top down“ lighting, perhaps
with one stoke up to ensure that the combustion chamber lining burns
clean again.
Why you need a chimney
The chimney is the wood-burning stove‘s motor; it‘s performance
decides how well your stove will work. The draft in the chimney crea-
tes a vacuum in the wood-burning stove. The vacuum draws the smoke
out of the stove, and takes in air through the combustion air baffle to
fuel the burning process. Combustion air is also used for the airwash
system that keeps the window clear of soot.
The draft in the chimney is caused by the difference in temperatures
inside and outside the chimney. The higher the temperature differen-
ce is, the better the draft in the chimney will be. It is thus important
for the chimney to reach operating temperature before you adjust
the damper to restrict combustion in the stove (a brickwork chimney
will take longer to reach operating temperature than a steel chim-
ney). It is very important to reach operating temperature as quickly
as possible on days on which the draft in the chimney is poor due to
unfavorable wind and weather conditions. Make sure the fuel ignites
as quickly as possible (with visible flames). Chop the wood into parti-
cularly small pieces; use an extra fire lighter etc.
After longer periods of disuse, check the chimney flue for blockage.
You can connect several units to the same chimney. But make sure
check with your chimney sweep to observe local regulations.
No matter how good your chimney is, it will not perform well if you do
not use it correctly. On the other hand a poor chimney, may give you
acceptable results if you use it correctly.
Using your stove in various weather conditions
Wind blowing on the chimney can have a great effect on how your
stove reacts in various wind conditions; you may need to adjust
the airflow to achieve good burning results. Fitting a damper in the
flue pipe may also help as it will give you the ability to regulate the
draught in changing wind conditions.
Fog can also have a great influence on how well a chimney draws; you
may again need to adjust the airflow settings to achieve good burning
results.
General Notes
Please note! Parts of the wood-burning stove, especially the outer
surfaces, become hot during use. Please exercise due care.
Never empty ashes into a flammable container. Ashes can contain
glowing embers long after you finish using your wood stove.
While the stove is not in use you can close the valves to avoid draught
through the stove.
After longer breaks you should check the smoke outlet paths for
blockages before lighting.
Chimney fires
In case of a chimney fire, keep the stove door and the valves on the
stove closed. In case of emergency, call the fire service.
It is recommended that you get a chimney sweep to check the chim-
ney before using the stove again.
Handling fuels
Selecting Wood/Fuel
You can use any type of wood as firewood, however, harder types,
such as beech, ash, are generally better for heating as they burn more
evenly and create less ash. Other wood types like maple, birch and
spruce are excellent alternatives.
Handling
Firewood is best if you fell the tree, and saw and split the wood,
before May 1st. Remember to cut the logs to match the size of your
wood-burning stove‘s combustion chamber. We recommend a dia-
meter of 6-10 cm. The length should be about 6 cm shorter than that
of the combustion chamber to leave enough space for air to circulate.
Firewood with a greater diameter needs splitting. Split wood dries
faster.
Storing
You need to store the sawn and split firewood in a dry place for 1-2
years before burning. Wood dries faster if you stack it in an airy place.
Before use, store the firewood for a few days at room temperature.
Note that wood absorbs moisture during the autumn and winter
seasons.
Moisture
To avoid environmental issues, and for optimum burning, wood has to
be perfectly dry to be suitable for use as firewood. The max. residual
moisture in the wood should not exceed 20%. A moisture content of
15-18% yields best results. As an easy way of checking if wood is
dry, just knock two pieces of wood together. If the wood is moist, the
sound will be dull.
If you use damp wood, most of the heat it produces will be used to
evaporate the water. The temperature in the wood stove does not
rise, and the room is not sufficiently heated. Of course, this is not
economical, and it will cause soot build up on the glass pane, in the
stove, and in the chimney. Burning moist wood also causes pollution.
Understanding units for measuring wood
Various units of measurement are used for wood. Before you buy wood,
it makes sense to familiarise yourself with the terms. There are various
brochures, in public libraries for example, that cover this topic.
Use of the following as fuel is illegal
Painted, pressure impregnated, or glued wood, driftwood from the
sea. Never burn chipboard, plastics, or chemically treated paper.
These materials are dangerous to humans, to the environment, your
wood stove, and your chimney. To keep a long story short – make sure
you burn only quality firewood.
Firewood fuel value
The fuel value is different for different types of wood. In other words,
you need to use more wood of certain types to achieve the same hea-
ting performance. This Instruction Manual assumes that you will be
using beech, which has a very high fuel value, and is also a wood that
is easy to procure. If you use oak or beech wood fuel, note that these
wood types have a greater fuel value than, say, birch. Make sure you
use less fuel to avoid damage to the wood-burning stove.
Wood types Kg Dry wood/m
3
Compared to
beech
Hornbeam 640 110%
Beech/Oak 580 100%
Ash 570 98%
Maple 540 93%
Birch 510 88%
Pine 480 83%
Fir 390 67%
Poplar 380 65%
23
MAINTENANCE
Servicing
We recommend that the stove should have a comprehensive servicing
at least once every two years. Servicing should include the following:
Lubricate hinges using copper grease
Check gaskets. Replace any that are broken or weak.
Check combustion chamber door and riddling grate
Check combustion chamber lining and baffle plates.
The stove must be serviced by a qualified fitter. Use only orignal
spare parts.
Maintaining your wood-burning stove
Apart from regular chimney sweeping, your wood-burning stove does
not require any regular maintenance. However, we recommend servi-
cing at least once every two years
Use only original replacement parts for maintenance and repairs of
your stove.
Note! Make sure the wood-burning stove is cold before starting
maintenance or repair work.
Coated surfaces
Clean your wood-burning stove by dusting with a dry, lint-free cloth.
If the topcoat is damaged, you can purchase a repair spray from your
authorised Scan dealer. As slight differences in colour are possible,
spray a larger area to achieve a natural transition for best results.
For best results, apply repair spray when the wood-burning stove is
hand-hot.
Cleaning the glass
Our wood-burning stoves are designed to prevent serious soot build
up on the glass. The best way to achieve this is to make sure you have
a sufficient combustion air supply. It is also important to use dry
wood, and have a correctly dimensioned chimney.
Even if you follow all of our instructions, a slight film of soot can build
up on the glass. You can easily remove this build up by cleaning with a
dry cloth and glass cleaner. Please note that the glass cleaner is not
to get into contact with the gaskets, as this can discolour the glass
permanently.
Combustion chamber lining
Slight cracks can appear in the combustion chamber lining due to
moisture, or to the heating/cooling process. These cracks have no
influence on the heating performance or lifetime of your stove.
However, if the lining starts to crumble, you must replace it. The com-
bustion chamber lining is not covered by the warranty.
Gaskets
All wood-burning stoves have gaskets made of ceramic material fitted
to the stove, the doors, and/or the glass. These gaskets are subject to
wear and tear, and must be replaced when necessary.
Chimney sweeping and cleaning your
wood-burning stove
Follow national and local chimney sweeping regulations. We
recommend having the wood-burning stove cleaned regularly by the
chimney sweep.
Before starting to clean your wood-burning stove, and sweep the flue
pipe, we recommend first removing the baffle plates.
Checking the stove
Scan A/S recommends that you check your stove thoroughly after
sweeping/cleaning. Check all visible surfaces for cracks. Check that
all joints are tight and that the seals sit correctly. Worn or deformed
seals should be replaced.
Service
Baffle plates and combustion chamber liningg
Be very careful when removing the baffle plates from the stove.
Lift the burn chamber side plates free from the bottom stones and
take them out. Please note that the sides support the rear plates and
that these may fall over, when the sides are taken out.
Take out the rear plates.
TROUBLESHOOTING
24
Smoke escaping
Damp wood
Chimney not drawing properly
Chimney is not properly dimensioned for the stove
Check if the smoke gas pipe/chimney are blocked
Is the chimney the right height for its surroundings?
At rear outlet, check that the flue pipe does not obstruct the
chimney draught
Vacuum in room
The door is opened before the embers have burned down
sufficiently
Wood burning too quickly
Incorrect secondary/primary airflow setting
The baffle plates is incorrectly mounted or missing
Inferior firewood (waste wood, pallets etc.)
Chimney too large
Soot build-up on glass
Incorrect secondary/primary airflow setting
Damp wood
Wood pieces too large on lighting
Inferior firewood (waste wood, pallets etc.)
Chimney not drawing sufficiently
Vacuum in room
Excessive soot build-up in chimney
Poor burning (more air required)
Damp wood
The surface of the stove is turning grey
Overheating (see instructions for heating)
Poor heating performance of stove
Damp wood
Not enough wood
Inferior wood quality with low fuel value
Baffle plates are not fitted correctly
Odour coming from stove
The lacquer on the stove hardens when you use the stove for the
first time; this can cause an odour. Open a window or a door for
ventilation, and make sure the stove is heated up sufficiently to
avoid odours later.
When heating up and cooling down, the stove may make some
clicking noises. These are due to the huge temperature diffe-
rences to which the material is exposed and do not indicate any
product defects.
Warranty
All wood-fired Scan products are made of high-quality materials and
subject to strict quality controls before leaving the factory. We give a
warranty of 5 years on manufacturing errors or defects.
You must quote your stove‘s product registration number when you
contact us or your authorised Scan dealer with a warranty claim.
The warranty covers all parts which in the opinion of Scan A/S require
repair or replacement due to manufacturing or construction error
The warranty applies to the original purchaser of the product only,
and is not transferable (except on prior sale).
The warranty covers only damage caused by manufacturing or con-
struction errors.
The following parts are not covered by the war-
ranty
Wear and tear parts, such as the combustion chamber liners,
baffle plates, riddling grate, glass, tiles, and seals (except for
defects which were present on delivery).
Defects caused by external chemical and physical influences
during transportation, storage and assembly, or at a later time.
Soot build-up caused by poor chimney draught, damp wood, or
improper use.
Costs of additional heating in connection with a repair.
Transport costs.
Costs for setting up, removing the wood stove.
This warranty is void
In case of incorrect installation (the installer is responsible
for observing and complying with legal requirements and local
bylaws, along with this Assembly- and Instructionsmanual for
the wood-burning stove and accessories).
In case of improper use, and/or use of prohibited fuels, non-
original spares (see this Assembly- and instructions manual).
If the product registration number of the stove has been remo-
ved or damaged.
In case of repairs that do not comply with our instructions or
instructions by an authorised Scan dealer.
In case of any manipulation of the original state of this Scan
product or its accessories.
This warranty is only valid in the country to which this Scan pro-
duct was originally supplied.
Always use original replacement parts, or parts recommended by the
manufacturer.
TROUBLESHOOTING
25
DEFRA
Smoke Control Area air supply requirements
The M5x6 screw is fitted to ensure that the stove
receives sufficient air to meet Defra's requirements.
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1001\91001048.idw
91001048
Engelsk krav til luftspjæld
09-11-12
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1001\91001048.idw
91001048
Engelsk krav til luftspjæld
09-11-12
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
Screw M5x6
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new
fuel charge, excessive smoke emission can occur. Refuelling must
be carried out onto a sufficient quantity of glowing embers and ash
that the new fuel charge will ignite in a reasonable period. If there
are too few embers in the fire bed, add suitable kindling to prevent
excessive smoke
Fuel overloading
The maximum amount of fuel specified in this manual should not be
exceeded, overloading can cause excess smoke.
Operation with door left open
Operation with the door open can cause excess smoke. The appli-
ance must not be operated with the appliance door left open except
as directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can
cause excess smoke. The appliance must not be operated with air
controls, appliance dampers or door left open except as directed in
the instructions.
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or
part of the district of the authority to be a smoke control area. It
is an offence to emit smoke from a chimney of a building, from a
furnace or from any fixed boiler if located in a designated smoke
control area. It is also an offence to acquire an "unauthorised fuel"
for use within a smoke control area unless it is used in an "exempt"
appliance ("exempted" from the controls which generally apply in the
smoke control area).
In England appliances are exempted by publication on a list by the
Secretary of State in accordance with changes made to sections 20
and 21 of the Clean Air Act 1993 by section 15 of the Deregulation
Act 2015. Similarly in Scotland appliances are exempted by pub-
lication on a list by Scottish Ministers under section 50 of the
Regulatory Reform (Scotland) Act 2014.
In Wales and Northern Ireland these are authorised by regulations
made by Welsh Ministers and by the Department of the Environment
respectively.
Further information on the requirements of the Clean Air Act can be
found here: https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air
Act 1993 including designation and supervision of smoke control
areas and you can contact them for details of Clean Air Act require-
ments”
The Scan 1010 has been recommended as suitable for use in smoke
control areas when burning wood logs with a modification to thery
air valve so that it will not close beyond the 40% open position.
Important!
Please see installing the screw for secondary air
control with open position.
26
27
MAINTENANCE
28
14.02.2018
Version:
GB 91010 500
Scan A/S - DK-5492 Vissenbjerg
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

SCAN 1010 Series Assembly And Instruction Manual

Categoría
Estufas
Tipo
Assembly And Instruction Manual

en otros idiomas