Essick Air Products 5000 SD Manual de usuario

Tipo
Manual de usuario
Models
3000 DD N31D
3000 SD N30S
4001 DD N43/48D
4001 SD N40/45S
5000 DD N56/66D
5000 SD N55/65S
Circle the model of your cooler and
record the serial number below.
Read carefully all of this manual before
installing the unit.
Encierre con un circulo el modelo de su
enfriador y escribe el número de serie abajo.
Lea con cuidad todo este manual antes de
instalar la unidad.
Número De Serie
Safety Rules
1. Read instructions carefully.
2. Electrical hook up should be done by a quali ed electrician, so
that all electrical wiring will conform to your local standards.
3. Always turn OFF POWER and UNPLUG motor and pump inside
the cooler before installing or performing any maintenance.
4. Your cooler will run on either 120V or 240V A.C., single phase,
60 Hz (cycle) current.
5. Motor and pump have a grounded, molded plug and an automatic
thermal overload switch which will shut motor off when it over-
heats. The motor will restart automatically when it cools down.
6. Pump receptacle is for grounded evaporative cooler pump only.
Do not plug anything else into receptacle.
WARNING: To reduce the risk of re or electric shock, do not
use this fan with any “solid-state fan speed control device.”
Read And Save These Instructions
Vea el Español en el interior
110503-1 2-14
Evaporative Cooling
Evaporative cooling is nature’s way of cooling. When air is moved
over a wet surface, water is evaporated and heat is absorbed. When
stepping out of a swimming pool with the wind blowing, evaporative
cooling makes you feel cool, even though the air may be warm.
The human body itself is cooled primarily by the evaporation of
perspiration.
This unit works on the same principle. Air is drawn across wet
lter pads where the air is cooled by evaporation and then circulated
throughout the building. It is this combination of cooled air and the
movement of air over the skin which makes it feel cool.
www.championcooler.com
CHAMPION•ESSICK
Evaporative Cooler Manual
Unlike refrigeration systems which recirculate the air, an evaporative
cooler continually brings in fresh air while exhausting old air. You
are completely replacing the air every 2 to 4 minutes by opening
windows or doors or a combination of both. The air is always fresh,
not stale, laden with smoke and odors as happens with refrigerated
air conditioning.
Operation
For the best cooling performance, if the pads are dry, pre-wet the pads
by running the pump for a few minutes before starting the blower.
These coolers may be used without water for ventilation purposes.
When outside air is cool (for example, at night) or when humidity is
high, the water pump can be turned off.
A cooler can also be installed with a thermostat and attic exhaust
dampers to provide completely automatic operation.
Open Windows To Exhaust Air
An often misunderstood concept of evaporative cooling is the amount
of air that should be exhausted. How much should you open your
windows? The fact is that most people do not open their windows
enough. The following two methods will help you determine the
amount to open your windows.
CFM Method
You should allow an opening of at least 2 square feet (288 square
inches) for each 1000 CFM rating of your unit. Example: At 3654
CFM, model 4001 DD with a 1/2 hp motor requires 7.3 square feet
(1052 square inches) of opening (3654/1000 * 2 = 7.3). Multiply
the number of windows by window width in inches and divide this
into the number of square inches required for your size unit. This
will give you the height to open windows. In this example, four 36
inch wide windows should be opened 7.3 inches each.
Serial #
2
110503-1
Installation
NOTE: The pump comes installed. The belt, motor pulley, and motor cord
and oat are included in the cabinet, the motor is sold/shipped separately.
CAUTION: Make sure that the mounting surface is strong
enough to support the operating weight of the cooler when in use.
(For operating weight, see Speci cation Table.)
CAUTION: Never plug in cooler until installation is complete
and unit has been tested for rigidity.
• Install Duct Adapters. If desired, a 4 piece duct
adapter is available as an optional accessory.
Call 1-800-643-8341 to obtain these from the
factory. Align the holes in the duct adapter to the
holes in the blower opening and attach using the
provided screws (see Fig. 1). Repeat for all four
sides. Note: All 4 pieces are identical except for
models 5000SD & N55/65S which have an offset
piece which attaches to the bottom of the outlet.
To install this offset piece, remove the screws
holding the cut-off plate and slide the offset duct
adapter between the blower opening and the cut-
off plate. You may need to loosen other screws
to do this. Line up the holes and secure with the
screws previously removed.
Motor Installation
Install motor cord. For typical 120V op-
eration, connect motor cord to motor using
the following color code: Black - Hi, Red
- Low, White - Com., Green - Ground. (See
Wiring Diagrams)
Mount motor. Install blower motor in the
motor mount yokes, adjusting the yoke
if necessary. Fasten with the provided
mounting clips (see Fig. 2).
Install pulley. Install the adjustable mo-
tor pulley so that it aligns with the blower
drive pulley (see Fig. 3) and tighten set
screw.
Electrical Installation
WARNING: Disconnect all electrical service that will be used
for this unit before you begin the installation.
Com.
To Switch
Pump
Motor
Blower Motor
Red
Orange
Green
Black
Ground
Com.
Lo
Hi
= Wire Nut
Ground
Lo
Hi
Pump
Black
Red
White
Orange
Green
Green
Orange
Brown
White
Blue/Black
Motor
Clips
Adjustable
Yoke
Fig. 2
Remove junction box. The elec-
trical junction box is located in the
upper inside corner of the cooler
cabinet. Remove the two screws
and remove the junction box (Fig.
4). Slide receptacles into slots in
junction box.
Hook up electrical. Electrical hook up should be done by a quali ed
electrician, so that all electrical wiring will conform to your local standards.
This unit is suppled with a 120V pump. For 240V pump operation, a 240V
pump must be purchased. The fan and pump receptacles will support both
120V and 240V installations. See the wiring diagrams for 120V and 240V
installations. Note: Clip pump cord onto cord clip located on the bottom
of the junction box to keep cord our of the water.
IMPORTANT: When a single speed motor is used, do not use the red
lead on the receptacle and motor plug wiring. Tape off end of both of the
red leads.
CAUTION: Pump receptacle is for grounded evaporative
cooler pump only. Do not plug anything else into receptacle.
WARNING: Make sure the cooler cabinet is properly ground-
ed to a suitable ground connection for maximum safety.
Water Connection
Install over ow assembly. Place drain nipple
through the hole in the pan, with the rubber
washer between the pan and the head of the
drain nipple (Fig. 6). Screw on nut and draw
up tight against bottom of pan. Insert the
over ow pipe in the nipple to retain water.
The over ow pipe may be removed to drain
the pan when necessary. A garden hose may
be screwed on the drain nipple to drain water
away from your unit.
Connect water supply line. Find the
closest supply of water. Use a saddle
valve (Fig. 7) to connect 1/4” tubing to
the cold water supply or use a Sillcock
and water valve connected to an out-
side faucet (Fig. 8). Place the nut and
ferrule on the tubing and tighten the
nut until water tight. IMPORTANT:
Do not connect the water supply to any
soft water applications. Soft water
will cause corrosion and decrease the
life of the cooler.
Wiring Diagrams
240 Volts
Fig. 5
120 Volts
Champion Air Balancing Method
1. Take a piece of tissue paper and cut it lengthwise into 3 equal strips.
2. Turn your cooler on high cool.
3. Open one window at least six inches wide in each room that you want
to cool.
4. Take the piece of tissue paper and put it up against the screen of the open
window furthest from the cooler discharge opening. Let go of it. It will
do one of three things.
IF It falls down.
THEN CLOSE all of the windows one inch and try step 4 again.
IF It plasters itself to the screen.
THEN OPEN all of the windows one inch and try step 4 again.
IF It stays on the screen lightly.
THEN PERFECT. You are done. Enjoy your cooler.
NOTES:
When switching to low cool, you must rebalance your home. Repeat step
4.
Once you balance your home you can cool some areas more than others by
opening those windows more and closing the others by the same amount.
Repeat step 4 to make sure your home is still air balanced.
Blue/Black
White
Brown
Orange
Green
Green
Orange
White
Red
Black
Pump
Hi
Lo
Com.
Ground
= Wire Nut
Hi
Lo
Com.
Ground
Black
Green
White
Red
Blower Motor
Pump
Motor
To Switch
Blower
Housing
Motor
Pulley
Blower
Pulley
Fig. 3
Rubber Washer
Over ow Pipe
Nipple
Bottom Pan
Nut
Fig. 6
Cold
Water
Pipe
Saddle
Valve
1/4” Tubing
Fig. 7
Fig. 1
Duct Adapter
Cut-Off Plate
Screws
Fig. 4
Junction Box
Clip
3
110503-1
Install oat and attach water line to
oat. The oat may be installed in either
the corner post or bracket (see Fig. 9). If
you have model 3000DD/N31D then the
oat should be mounted to the bracket.
Refer to gure 10 for installation instruc-
tions. Insert the oat (1) thru the hole
in the corner post or bracket. Install the
washer (2) and nut (3). Tighten to keep
the oat from turning. Place the nut (5)
and ferrule (4) on the water supply line.
Connect to oat tting and tighten until
water tight.
Fill pan. Allow water to ll to
within 1” of top of pan and adjust
oat to maintain this water level.
This can be accomplished by bend-
ing the oat rod.
Level water troughs. Operate
pump until pads are saturated.
Check each trough to see if water
is evenly dispersed in the trough.
If they are not, loosen adjustment
bolts and level trough. Retighten
bolts. Check to see that all pads
are saturated with water and that
there are no dry spots or openings
in the pads.
Maintenance
WARNING: Before doing any maintenance be sure power is
off. At the time you remove a pad frame be sure to unplug motor
and pump. This is for your safety.
Spring Start-Up
Clean pump. Cleaning the pump is necessary once a year at start-up. For
your safety, turn unit off and unplug motor and pump. Remove the pump
from the mount slot. Remove the base of the pump (Fig. 13). Clean the
pump and turn the impeller to ensure free operation. Remove the pump
spout and check for any blockage.
After cleaning, reinstall the base
onto the pump. Press firmly to
make sure it is secure. Reattach
the pump to the mount in the cooler
using the plastic retainer to ensure
that the pump will not overturn. Do
not forget to replace the spout and
water delivery tube onto the pump
outlet.
Oil bearings. The blower bearings and cooler motor in this unit should be
oiled with a few drops of non-detergent 20/30 weight oil once each year.
The motor does not need oil if it has no oil lines for oiling. Motors that
have no lines are lifetime oiled at the factory and require no further oiling
for the life of the unit.
CAUTION: Do not over oil. Over oiling can cause motor burn
out, due to excessive oil getting into motor winding.
Change Pads. The pads should be replaced once or twice a season, de-
pending upon the length of the season. At the beginning and at mid season
a clean pad is more absorbent and ef cient and will deliver substantially
more cool air.
Check belt tension. A 3 lb. force should
de ect the belt 3/4 inches (see Fig. 14).
Readjust belt if needed.
Check bleed-off valve to be sure it is
not clogged.
WINTER SHUT DOWN
Drain water. Always drain all of the water out of the cooler and water
supply line when not in use for prolonged periods, and particularly at the
end of the season. Keep the water line disconnected from both the unit
and water supply so that it does not freeze.
Unplug motor and pump. When cooler is not used for extended periods,
unplug the motor and pump from inside cooler.
Cover unit. To protect the life of the nish, a cover for the unit is suggested
in extended periods of non use.
By following the operating, installation, and maintenance suggestions as
outlined, you can get many years of efficient and satisfactory service from
your cooler. In the event additional information is desired, your dealer will
be more than glad to assist you in every possible way.
Float
Corner
Post
Bracket
Fig. 9
Amperage Draw And Belt Tension
This unit is equipped with an adjustable motor drive pulley for adjusting
the blower wheel speed to the proper loading on different duct systems. It
is important that the motor drive pulley is adjusted to correct size to assure
maximum air delivery without damage to the motor. Be sure to follow these
instructions carefully.
Adjust drive pulley. After the unit is completely installed, adjust the drive
pulley to the least diameter and adjust belt tension. See the maintenance
section for adjusting belt tension.
Start cooler. Install all pad frames, start pump, and allow to operate until
pads are wet.
Check amperage. With pads wet and unit started, check amperage draw
with an amperage meter.
Adjust pulley if necessary. If amperage
draw is less than motor rating, turn off elec-
trical power and remove pad frame. Unplug
motor inside cooler, this will protect you
from someone turning on unit while you are
working inside. This should be done for your
safety. Adjust pulley to a larger diameter and readjust belt tension, plug
motor in, install pad frame, and retest amperage draw. Repeat this process
until correct amperage draw is attained. Increasing motor pulley diameter
increases amperage draw. Decreasing motor pulley diameter decreases
amperage draw (see Fig. 12).
CAUTION: Do not operate cooler with larger amperage draw
than speci ed on motor plate.
NOTE: No attempt should be made to completely install this unit without
the aid of an electrician or someone familiar with testing amperage draw.
Failure to comply with these instructions may void your warranty.
Decrease
Amperage
Fig. 12
Fig. 10
1
2
3
5
6
4
Faucet
Water Supply
Valve
Sillcock
Ferrule
Nut
Fig. 8
Fig. 14
3 Lb.
3/4 Inches
Bleed-Off
Installation of the bleed-off kit is recommended to increase the life of the
cooler. A bleed-off system is designed to prevent scale build up by continu-
ally removing a small percent of the water in the pan.
Install Bleeder Tee and Tubing.
Refer to gure 11. Cut the pump
hose and insert the barbed ends
of the bleeder tee into each cut
end. Insert one end of the bleeder
tubing onto the bleeder tee and
run the other end out of the cooler
through the over ow pipe. Note: A
restrictor clamp is provided which,
if desired, may be installed onto the
bleeder tubing to restrict the amount of water being bleed off. The amount
of water to bleed off depends on the quality of the water in your area. Start
with 1-2 gal/hr and increase if needed.
Restrictor
Over ow
Bleeder Tubing
Bleeder Tee
Pump Hose
Fig. 11
Impeller
Remove
Base
Fig. 13
4
110503-1
Limited Warranty
This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover dam-
ages incurred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us any other or
different liability in connection with this product.
Terms And Conditions Of The Warranty
For Eight Years from date of Purchase, we will replace the original base assembly if water leakage should occur due to rust out.
For One Year from date of Purchase, we will replace any original component provided by Champion Cooler which fails due to any defect in mate-
rial or factory workmanship only.
Exclusions From The Warranty
We are not responsible for replacement of cooler pads. These are disposable components and should be replaced periodically. We are not respon-
sible for any incidental or consequential damage resulting from any malfunction.
We are not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic wrap, or if a motor of a higher
horsepower than what is shown on the serial plate is used in the unit.
We are not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.
How To Obtain Service Under This Warranty
Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satis ed with the response from the dealer, contact
the Customer Service Department: 5800 Murray Street, Little Rock, Arkansas 72209. 1-800-643-8341. E-mail: info@championcooler.com.
This limited warranty applies to original purchaser only.
Problem Possible Cause Remedy
Failure to
start or no air
delivery
Inadequate
air delivery
with cooler
running
Inadequate
cooling
1. No electrical power to
unit
Fuse blown
Circuit breaker tripped
Electric cord unplugged
or damaged
2. Belt too loose or tight
3. Motor overheated
Belt too tight
Blower bearings dry
Motor pulley diameter
too large
4. Motor locked
1. Insuf cient air exhaust
2. Belt too loose
3. Pads plugged
4. Motor underloaded
1. Inadequate exhaust in
house
2. Pads not wet
Pads plugged
Open spots in pads
Trough holes clogged
Pump not working prop-
erly
1. Check power
Replace fuse
Reset breaker
Plug in cords or
replace if damaged
2. Adjust belt tension
3. Determine cause of
overheating
Adjust belt tension
Oil blower bearings
Adjust pulley to cor-
rect diameter
4. Replace motor
1. Open windows or
doors to increase air
ow
2. Adjust belt tension or
replace if needed
3. Replace pads
4. Adjust pulley to full
load ampere rating of
motor
1. Open windows or
doors to increase air
ow
2. Check water distribu-
tion system
Replace pads
Repack pads
Clean trough and
unplug holes
Replace or clean pump
(Unplug unit)
Troubleshooting
Problem Possible Cause Remedy
Motor cycles
on and off
Noisy
Musty or
unpleasant
odor
Water drain-
ing onto roof
Excessive
humidity in
house
1. Low voltage
2. Excessive belt tension
3. Blower shaft tight or
locked
4. Bearings dry
5. Motor pulley diameter
too large causing motor
overload
1. Bearings dry
2. Wheel rubbing blower
housing
3. Loose parts
1. Stale or stagnate water
in cooler
2. Pads mildewed or
clogged
3. Pads not wetting prop-
erly
Trough holes clogged
Pump not working
properly
1. Float arm not adjusted
properly
2. Over ow assembly
leaking
1. Inadequate exhaust
1. Check voltage
2. Adjust belt tension
3. Oil or replace bearings
(Unplug unit)
4. Oil bearings
5. Adjust pulley so full
load ampere rating of
motor is not exceeded
1. Oil bearings
2. Inspect and realign
(Unplug unit)
3. Tighten loose parts
1. Drain pan and clean
pads
2. Replace pads
3. Check water distribu-
tion system
Clean
Replace or clean pump
(Unplug unit)
1. Adjust oat
2. Tighten nut and over-
ow pipe.
1. Open doors or win-
dows
Register your product online at www.championcooler.com/index.php/cooler-warranty-registration
5
110503-1
No. 3000 DD 4001 DD 5000 DD
Description / Descripción N31D N43/48D N56/66D
1. Top Pan / Tapa ----------------------------------------------------------------------------------------222903-003 220901-002 220903-002
2. Bottom Pan / Base De La Caja ---------------------------------------------------------------------322907-002 320905-007 320906-005
3. Louvered Side Assembly / Montaje De Reja Lateral -------------------------------------------324006-303 (4) 324007-105 (4) 324008-303 (4)
4. Water Trough / Canal De Agua ---------------------------------------------------------------------226003-001 (4) 226003-002 (4) 226003-003 (4)
5. Aspen Pads / Filtros De Paja -----------------------------------------------------------------------110091 (4) 110098 (4) 110092 (4)
6. Pad Retainers / Soporte Para El Filtro ------------------------------------------------------------3PW-3 (12) 3PW-5 (12) 3PW-6 (16)
7. Corner Post / Poste De Esquina --------------------------------------------------------------------324003-052 324003-054 324003-055
10. Cut-Off Plate / Placa Limitadora ------------------------------------------------------------------224002-001 224004-002 224004-003
11. Blower Housing / Caja De La Rueda --------------------------------------------------------------324106-202 324107-007 324111-001
12. Blower Wheel / Rueda -------------------------------------------------------------------------------12BW 16BW 20BW
13. Shaft, Blower Wheel / Eje De La Rueda ----------------------------------------------------------110182 110183 110183
14. Bearings, Blower Wheel Shaft / Cojinetes Del Eje De La Rueda -----------------------------110351 (2) 110351 (2) 110351 (2)
15. Pulley, Blower Wheel / Polea De La Rueda ------------------------------------------------------110274 110275 110276
16. Drive Belt / Correa -----------------------------------------------------------------------------------110211 110215 110214
17. Motor / Motor -----------------------------------------------------------------------------------------* * *
18. Pulley, Motor / Polea Del Motor -------------------------------------------------------------------110277 110278 110278
19. Motor Mount / Montura Del Motor ----------------------------------------------------------------314003-002 314003-004 314003-008
20. Motor Mount Clip Set / Conjunto De Seguros Para Montar Motor --------------------------314005-001 314005-001 314005-001
21. Electrical Cord, Motor (115V) / Cable Eléctrico Del Motor (115V) --------------------------110372 110372 110372
21. †Electrical Cord, Motor (230V) / Cable Eléctrico Del Motor (230V) ------------------------ †110372-2 †110372-2 †110372-2
22. Float Valve / Flotador -------------------------------------------------------------------------------FL-C FL-C FL-C
23. Pump Mount / Montura De La Bomba ------------------------------------------------------------218001-030 218001-031 218001-031
25. Pump / Bomba ----------------------------------------------------------------------------------------110428 110429 110429
26. Pump Retainer / Sujetador De La Bomba ---------------------------------------------------------
110714 110714 110714
27. Air Baf e / Ba e De Aire ---------------------------------------------------------------------------224112-001 - 224108-003
28. Float Bracket / Soporte Del Flotador --------------------------------------------------------------216001-003 216001-003 216001-003
29. Tube, Water Delivery / Tubo De Agua -------------------------------------------------------------310716 310716 310716
30. Over Flow Assembly / Montaje De Desagüe -----------------------------------------------------3OA-1 3OA-1 3OA-1
31. Water Distributor Assembly / Sistema Del Distribuidor De Agua -----------------------------3D-4 3D-5 3D-6
32. Holder, Water Distributor / Soporte Para El Distribuidor De Agua --------------------------110574 (4) 110574 (8) 110574 (8)
33. Electrical Junction Box / Caja De Empalme -----------------------------------------------------320106-002 320106-002 320106-002
34. Receptacle, Motor / Tomacorriente Del Motor ---------------------------------------------------110393 110393 110393
35. Receptacle, Pump / Tomacorriente De La Bomba -----------------------------------------------110361 110361 110361
36. Bearing Mount, Right / Montura Del Cojinete, Derecha ---------------------------------------- - 214114-003
37. Bearing Mount, Left / Montura Del Cojinete, Izquierda ----------------------------------------- - 214114-001
38. Motor Mount Support, Right / Soporte Para El Montura Del Motor, Derecho--------------- - 214114-004
39. Motor Mount Support, Left / Soporte Para El Montura Del Motor, Izquierdo --------------- - 214114-002
40. Channel Retainer Support / Soporte Para El Retendedor De Canal -------------------------- - 218114-001 (2)
41. Bleed-Off Kit / Equipo De Purga -----------------------------------------------------------------310586 310586 310586
* See motor speci cation table. Motors sold separately / Vea la tabla de especi caciones del motor. Motores se vende por separado.
† 230V motor cord is optional and not supplied with cooler. / Cable eléctrico del motor de 230V es opcional y no se envía con el enfriador.
NOTE: Standard hardware items may be purchased from your local hardware store.
NOTA: Artículos de uso corriente pueden comprarse en la ferretería de su localidad.
Replacement Parts List / Lista De Piezas De Recambio
When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. /
Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora.
1. Cooler model number / El modelo de su enfriador
2. Cooler serial number / Número de serie de la unidad
3. Motor HP / C.V. del motor
4. Description and part number / Descripción y número de pieza
5. Date of purchase / Fecha de compra
6
110503-1
General Speci cations / Especi caciones Generales
Model No.
Modelo
HP
C.V.
Weight (lbs.)
Peso (libras)
Cabinet Dimensions (in.)
Dimensiones De La Caja (pulgadas)
Duct Opening (in.)
Abertura De Ducto (pulgadas)
*Dry
Seco
*Operating
Lleno
Height
Altura
Width
Anchura
Depth
Profundidad
Width
Anchura
Height
Altura
3000DD &
N31D
1/3 125 175 33 7/16 28 1/8 28 1/8 13 5/8 13 5/8
4001DD &
N43/48D
1/3
1/2
165
166
232
233
34 1/2 34 1/8 34 1/8 17 3/4 17 3/4
5000DD &
N56/66D
1/2
3/4
222
226
305
309
42 7/16 39 39 19 3/4 19 3/4
3000SD &
N30S
1/3 116 193 33 7/16 28 1/8 28 1/8 13 5/8 13 5/8
4001SD &
N40/45S
1/3
1/2
154
155
268
269
34 1/2 34 1/8 34 1/8 17 3/4 17 3/4
5000SD &
N55/65S
1/2
3/4
204
208
353
357
42 7/16 39 39 19 3/4
20 9/16
(19 3/4 with
adapter)
*I ld t iht/Il l dl
Parts Drawing / Dibujo De Piezas
3000DD, 4001DD, 5000DD
N31D, 43/48D, 56/66D
7
110503-1
Motor Speci cations / Especi caciones Del Motor
Model No.
Modelo
HP
C.V.
Motor Part #
Motor - N°
Speed
Velocidad
Volts
Voltios
**Amperage
Amperaje
*Motor Pulley Part #
Polea Del Motor -
Drive Belt Part #
Correa - N°
3000DD, N31D,
3000SD & N30S
1/3
110444
110445
1
2
115 7.2 110277 110211 (4L-450)
4001DD, N43/48D,
4001SD & N40/45S
1/3
110444
110445
1
2
115 7.2
110278 110215 (4L-560)
1/2
110446
110447
1
2
115 9.8
5000DD, N56/66D,
5000SD & N55/65S
1/2
110446
110447
1
2
115 9.8
110278
(DD, D) 110214 (4L-690)
(SD, S) 110213 (4L-670)
3/4
110448
110449
1
2
115 13.8
Parts Drawing / Dibujo De Piezas
3000SD, 4001SD, 5000SD
N30S, N40/45S, N55/65S
* 1/2” Bore x Adjustable O.D. / Taladro de 1/2 pulgadas x Diámetro Externo Ajustable.
** Amperage shown is from National Electric Code. Use motor nameplate for more accurate amp reading. / El amperaje listado es del código
eléctrico nacional. Utilice el amperaje indicado en la place del motor para un amperaje más exacto.
8
110503-1
No. 3000 SD 4001 SD 5000 SD
Description / Descripción N30S N40/45S N55/65S
1. Top Pan / Tapa ..................................................................................................................222903-002 220901-001 220903-001
2. Bottom Pan / Base De La Caja .........................................................................................222904-003 220902-002 220905-006
3. Louvered Side Assembly / Montaje De Reja Lateral .......................................................324006-303 (3) 324007-205 (3) 324008-303 (3)
4. Water Trough / Canal De Agua ........................................................................................226003-001 (3) 226003-002 (3) 226003-003 (3)
5. Aspen Pads / Filtros De Paja ...........................................................................................110091 (3) 110098 (3) 110092 (3)
6. Glass Fiber Pads / Filtros De Vidrio .................................................................................- 110129-003 (3) -
7. Pad Retainers / Soporte Para La Esponja ........................................................................3PW-3 (9) 3PW-5 (9) 3PW-6 (12)
8. Corner Post / Poste De Esquina .......................................................................................324003-053 324003-054 324003-056
10. Front Panel / Panel De Frente ..........................................................................................224106-001 224105-005 222108-004
11. Cut-Off Plate / Placa Limitadora .....................................................................................224002-001 224004-001 224004-001
12. Blower Housing / Caja De La Rueda ...............................................................................324106-102 324107-206 324108-004
13. Blower Wheel / Rueda ......................................................................................................12BW 16BW 20BW
14. Shaft, Blower Wheel / Eje De La Rueda ..........................................................................110182 110183 110183
15. Bearings, Blower Wheel Shaft / Cojinetes Del Eje De La Rueda ....................................110351 (2) 110351 (2) 110351 (2)
16. Pulley, Blower Wheel / Polea De La Rueda .....................................................................110274 110275 110276
17. Drive Belt / Correa ...........................................................................................................110211 110215 110213
18. Motor / Motor ...................................................................................................................* * *
19. Pulley, Motor / Polea Del Motor ......................................................................................110277 110278 110278
20. Motor Mount / Montura Del Motor ..................................................................................314003-006 314003-004 314003-004
21. Motor Mount Clip Set / Conjunto De Seguros Para Montar Motor ................................314005-001 314005-001 314005-001
22. Electrical Cord, Motor (115V) / Cable Eléctrico Del Motor (115V) ................................110372 110372 110372
22. §Electrical Cord, Motor (230V / Cable Eléctrico Del Motor (230V) ..............................§110372-2 §110372-2 §110372-2
23. Float Valve / Flotador .......................................................................................................FL-C FL-C FL-C
24. Pump Mount / Montura De La Bomba .............................................................................218001-031 218001-031 218001-031
26. Pump / Bomba ..................................................................................................................110428 110429 110429
27. Pump Retainer / Sujetador De La Bomba ........................................................................110714 110714 110714
28. Tube, Water Delivery / Tubo De Agua ..............................................................................310716 310716 310716
29. †Duct Adapters / Adaptores Del Conducto.......................................................................†324016-001 †324016-002 †324016-003
30. Over Flow Assembly / Montaje De Desagüe ...................................................................3OA-1 3OA-1 3OA-1
31. Water Distributor Assembly / Sistema Del Distribuidor De Agua ...................................3D-2 3D-10 3D-9
32. Holder, Water Distributor / Soporte Para El Distribuidor De Agua ................................110574 (3) 110574 (6) 110574 (6)
33. Electrical Junction Box / Caja De Empalme ....................................................................320106-002 320106-002 320106-002
34. Receptacle, Motor / Tomacorriente Del Motor ................................................................110393 110393 110393
35. Receptacle, Pump / Tomacorriente De La Bomba ............................................................110361 110361 110361
36. Float Bracket / Soporte Del Flotador ...............................................................................216001-003 216001-003 216001-003
37. Bleed-Off Kit / Equipo De Purga .....................................................................................310586 310586 310586
38. Air Baf e / Ba e De Aire .................................................................................................- 222119-002 224108-003
* See motor speci cation table. Motors sold separately. / Vea la tabla de especi caciones del motor. Motores se vende por separado.
† Optional Accessory. Not included with unit. / Accesorio opcional. No incluido con la unidad.
§ 230V motor cord is optional and not supplied with cooler. / Cable eléctrico del motor de 230V es opcional y no se envía con el enfridor.
NOTE: Standard hardware items may be purchased from your local hardware store.
NOTA: Artículos de uso corriente pueden comprarse en la ferretería de su localidad.
Replacement Parts List / Lista De Piezas De Recambio
When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. /
Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora.
1. Cooler model number / El modelo de su enfriador
2. Cooler serial number / Número de serie de la unidad
3. Motor HP / C.V. del motor
4. Description and part number / Descripción y número de pieza
5. Date of purchase / Fecha de compra
9
110503-1
Funcionamiento
Para que no salga aire caliente al principio, prenda sólo la bomba durante
unos cuantos minutos; luego prenda también el motor del ventilador.
Su unidad puede ser utilizada sin agua para proporcionar ventilación
solamente. Cuando hace fresco (por ejemplo, de noche) o cuando la
humedad es alta, la bomba de agua puede ser apagada.
La unidad puede ser instalada también con termostato y reguladores
de escape en el ático para obtener un funcionamiento totalmente
automático.
¿Cuánto Debe Abrir Las Ventanas?
Un concepto a menudo entendido mal de enfriamiento por evaporación
es la cantidad de aire que debe ser agotada. Cuánto debe usted abrir sus
ventanas? El hecho es que la mayoría de la gente no abre sus ventanas
bastante. Los dos métodos siguientes le ayudarán.
El Método De PCM
Usted debe dejar una abertura de dos pies cuadrados por cada 1000
P.C.M. (pies cúbicos por minuto), según la capacidad de su modelo.
Ejemplo: El Modelo 4001 DD con un motor de 1/2 C.V. y con un
rendimiento de 3654 P.C.M. requiere 7,3 pies cuadrados (1051 pulgadas
cuadradas) de abertura (3654/1000 * 2 = 7,3). Ahora, multiplique el
número de las ventanas por el ancho de las mismas; luego divida esta
cantidad entre el número de pulgadas cuadradas requeridas para su
unidad. El resultado le dice hasta qué altura hay que abrir las ventanas.
En este ejemplo, cuatro ventanas que miden 36 pulgadas (0,9 m.) de
ancha se deben abrir 7,3 pulgadas por cada una.
El Método De Equilibrar El Aire
1. Tome un pedazo de papel de seda y córtelo a lo largo en 3 tiras
iguales.
2. Ponga en marcha a su enfriador a “High-Cool”.
3. Abra una ventana por lo menos seis pulgadas de ancho en cada sitio
que usted desee refrescar.
4. Tome un pedazo de papel de seda y póngalo contra la pantalla de la
ventana abierta más lejos de la apertura del enfriador. Suéltalo al
papel de seda. Hará una de tres cosas:
SI: Se caiga.
ENTONCES: CIERRE todas las ventanas una pulgada e intente el
paso 4 otra vez.
SI: Se queda contra la pantalla con fuerza.
ENTONCES: ABRA todas las ventanas una pulgada e intente el
paso 4 otra vez.
SI: Se queda ligeramente contra la pantalla.
ENTONCES: PERFECTO. Se ha acabado. Goce del aire refrescan-
te.
NOTAS:
Al poner el enfriador a “low-cool”, usted debe reequilibrar el aire de
su hogar. Repita el paso 4.
Al equilibrar el aire de su hogar usted puede refrescar algunas áreas
más que otras abriendo esas ventanas más y cerrando las otras por
la misma cantidad. Repita el paso 4. Asegurarse de que el aire de su
hogar sea equilibrado.
Reglas De Seguridad
1. Lea las instrucciones con cuidado.
2. Las conexiones eléctricas deben ser hechas por un electricista com-
petente, para que todo el cableado eléctrico cumpla con los requisitos
establecidos en su localidad.
3. Siempre CORTE LA CORRIENTE y DESCONECTE el motor y la
bomba en el interior del aparato antes de instalar o realizar cualquier
labor de mantenimiento.
4. Su enfriador funciona con corriente alterna de 120V o 240V, de una
fase y 60 Hz. (ciclos).
5. El motor y la bomba están provistos de clavijas moldeadas, con toma
de tierra, y se apagarán automáticamente en caso de sobrecalenta-
miento. Los motores volverán a funcionar cuando se enfrían.
ADVERTENCIA: Para reducir el riesgo de incendio o toques
eléctricos, no use este ventilador con ningún “dispositivo de estado
sólido para controlar la velocidad del ventilador.”
Enfriamiento Por Evaporación
El enfriamiento por medio de evaporación es la manera de la naturaleza
de refrescarse. Cuando el aire se mueve sobre una super cie mojada,
se evapora el agua y se absorbe el calor. Al salir de una piscina con
el viento que sopla usted se siente fresco, aunque el aire puede ser ca-
liente. El cuerpo humano sí mismo es refrescado principalmente por
la evaporación del sudor.
Este enfriador funciona usando el mismo principio. El aire se traza
a través de los ltros mojados donde el aire se enfría por medio de
evaporación y después circula a través del edi cio. Se hace frío de la
sensación cuando tiene esta combinación del aire enfriado y del movi-
miento del aire sobre la piel.
A diferencia de los acondicionadores de aire que recirculan el aire,
un enfriador evaporativo trae continuamente por dentro el aire fresco
mientras agota el aire viejo. Se reemplaza completamente el aire cada
2 a 4 minutos, abriendo las ventanas o las puertas o una combinación
de ambas. El aire es siempre fresco, no es viciado, cargado de humo
y olores como ocurre con los sistemas de aire acondicionado a base de
refrigeración.
Instalación
NOTA: Los enfriadores vienen con la bomba instalada. La banda, la
polea del motor, y el cable del motor y el otador están incluidos en la
unidad. El motor se vende y se envía por separado.
PRECAUCIÓN: La super cie en que ha de colocarse el
enfriador deberá aguantar el peso completo de la unidad cuando
ésta está en funcionamiento. (Para saber este peso, vea la tabla
de especi caciones.)
PRECAUCIÓN: No conecte el enfriador hasta que la ins-
talación esté completa y se haya comprobado la estabilidad del
mismo.
Instale los adaptadores del conducto. Un adaptador del conducto
de 4 pedazos es disponible como un accesorio opcional. Llame 1-
800-643-8341 para obtener éstos de la fábrica.
Alinee los agujeros en los adaptadores con los
agujeros en los lados del salida y sujételos
con los tornillos proporcionados (véase g.
1). Nota: Los 4 pedazos son idénticos a ex-
cepción del modelos 5000SD y N55/65S, lo
cuales tienen un pedazo formado que sujeta
al fondo del salida. Para instalar este pedazo
formado, quite los tornillos de la placa limita-
dora y deslice el pedazo formado entre la placa
limitadora y la salida. Puede necesitar a ojar
otros tornillos para realizar esto. Alinee los
agujeros y sujete el adaptador con los tornillos
quitados previamente.
Lea y Conserve Estas Instrucciones
Fig. 1
Adaptor De
Conducto
Placa Limitadora
10
110503-1
Conectar El Agua
Instale el montaje de desagüe. Pase la boquilla por el agujero de la
bandeja, colocando la arandela de goma entre la bandeja y la cabeza de
la boquilla (véase g. 5). Coloque la tuerca en la boquilla y atorníllela
hasta que quede apretada contra la parte
inferior de la bandeja. Inserte el tubo
de desagüe en la boquilla para retener
el agua. El tubo de desagüe se puede
quitar para desaguar el agua de la bandeja
cuando sea necesario. Se puede conectar
una manguera de jardín a la boquilla para
desaguar el agua hacia otra parte.
Conecte el tubo de abastecimiento de agua. Encuentre el abasteci-
miento de agua más cercano. Utilice la válvula de la montura ( g. 6)
para conectar la tubería del cobre de 1/4 pulgada con el abastecimiento
de agua fría de la casa, o utilice una llave de paso y la válvula de agua
conectada con un grifo exterior
( g. 7). Coloque la tuerca y la
férula en el tubo y apriete bien
la tuerca para impedir que gotee
el agua. IMPORTANTE: No
conecte el abastecimiento de agua
con ninguna aplicación de agua
blanda. El agua blanda disminuirá
la vida del enfriador.
Instale el flotador y conecte el
tubo de agua al otador. Instale
el otador en el poste de esquina o
el soporte según indica la gura 8.
Si tiene el modelo 3000DD/N31D,
instale el otador en el soporte so-
lamente. Véase la gura 9 para las
instrucciones de instalar el otador.
Inserte el otador (1) por el agujero
en el poste o el soporte. Instale
la arandela de hule (2) y la tuerca
(3). Apriete la tuerca para que
el otador no de vuelta. Ponga
la tuerca (5) y la férula (4) en le
línea de abastecimiento de agua
(6). Conecte la línea al otador y
apriete la tuerca hasta que no salga
agua.
Llene la bandeja con agua.
Permita que se llene la bandeja
con agua hasta una altura de una
pulgada por debajo del borde
superior de la bandeja y ajuste
el flotador para que mantenga
este nivel. Esto se puede lograr
torciendo la varilla del otador
para arriba o para abajo.
• Nivele los canales de agua. Ponga a funcionar la bomba hasta saturar
de agua los ltros. Luego revise cada canal para ver si la distribución
del agua es pareja. Si no es así, a oje los tornillos de ajuste y nivele
cada canal. Vuelva a apretar los tornillos. Compruebe que todos los
ltros hayan quedado saturados de agua y que no contengan áreas secas
o roturas.
Instalación Del Motor
Instale el cable del motor. Para la instalación típica de 120V, conecte
el cable al motor usando las claves de colores siguientes: Negro - Alto,
Rojo - Bajo, Blanco - Común, Verde - Tierra. (Vea la esquema del
cableado).
Monte el motor. Instale el motor del ventilador en las horquillas de la
montura. Ajuste la horquilla ajustable si es necesario y sujete el motor
con los seguros (véase g. 2).
Instale la polea del motor. Instale la polea ajustable del motor para
que queda alineada con la polea del ventilador (véase g. 3) y apriete
el tornillo.
Instalación Eléctrica
ADVERTENCIA: Desconecte todos los servicios eléctricos
que serán usados en esta unidad antes de instalar el enfriador.
Quite la caja de empalme. La
caja de empalme se encuentra
en el rincón superior del inte-
rior del enfriador. Quite los
dos tornillos de la caja y quite
la caja de empalme (fig. 4).
Deslice las tomacorrientes a la
ranura de la caja de empalme.
Conecte el cableado eléctrico. Las conexiones eléctricas deben
ser hechas por un electricista competente, para que todo el cableado
eléctrico cumpla con los requisitos establecidos por su localidad. Esta
unidad viene equipado con una bomba de 120V. Para la alimentación
de 240V, necesita comprar una bomba de 240V. Las tomas de corriente
del ventilador y bomba soportan ambas instalaciones de 120V y 240V.
Vea las esquemas del cableado para las instalaciones de 120V y 240V
en la página 11. Nota: Sujete el cable de la bomba en el clip situado
en el fondo de la caja de empalme para no tocar el agua.
IMPORTANTE: Con un motor de una sola velocidad, no use la línea
roja en el cableado del enchufe y la clavija del motor. Envuelva el
extremo de ambas líneas rojas con cinta eléctrica.
PRECAUCIÓN: Enchufe una bomba del enfriador evapora-
tivo solamente y nada más al receptáculo de la bomba.
ADVERTENCIA: Asegúrese de que el enfriador tiene una
conexión apropiada a toma de tierra.
Amperio Y Tensión De La Correa
Esta unidad viene equipada de una polea ajustable que permite ajustar la
velocidad del ventilador segun la capacidad del motor en diferentes sistemas
Seguros
Horquilla
Ajustable
Fig. 2
Caja De
La Rueda
Polea Del
Motor
Polea Del
Ventilador
Fig. 3
Tornillos
Fig. 4
Caja De
Empalme
Arandela De Goma
Tubo De Desagüe
Boquilla Roscada
Bandeja
Tuerca
Fig. 5
Abastecimiento
De Agua Fría
Válvula De
La Montura
Tubería Del
Cobre
Fig. 6
Flotador
Poste De
Esquina
Soporte
Fig. 8
Fig. 9
1
2
3
5
6
4
Grifo
Válvula
De Agua
Llave De
Paso
Ferula
Tuerca
Fig. 7
Sistema de Purga
Recomendamos instalar la sistema de purga para aumentar la vida del enfriador.
La sistema de purga es diseñada prevenir la acumulación de escama en el agua
quitando continuamente una cantidad pequeña del agua en la bandeja.
Instale la te y tubo de pur-
ga. Véase la gura 10. Corte
el tubo del bomba e inserte
los extremos estriados de
la te a cada uno extremo
cortado del tubo. Instale el
tubo de purga insertando un
extremo sobre la te y el otro
extremo pasando hacía afue-
ra del enfriador por medio
del tubo de desagüe.
Nota: Está provisto con un reductor de ujo de agua lo cual, si desea,
se puede instalar en el tubo de purga para restringir la cantidad del agua
purgado. La cantidad de agua purgado depende de la calidad de agua
en su área. Comience con 1 a 2 galones por hora y aumente si está
necesitado.
Reductor
Tubo De Desagüe
Tubo De Purga
Te De Purga
Tubo De Bomba
Fig. 10
11
110503-1
motor y la bomba. Quite el suje-
tador de plástico de la montura y
jale la bomba, deslizándola hacia
usted. Quite la base de la bomba
(véase g 12). Limpie la bomba.
Dé le vuelta a la hélice para ve-
ri car que se mueve libremente.
Quite el pico de la bomba y vea
si está obstruido. Después de lim-
piar, reinstale la base en la bomba.
Presione rmemente para asegurarse de que es segura. Vuelva a colocar
la bomba en la unidad y fíjela en su montura con el sujetador de plástico.
Esto impedirá que se caiga la bomba al agua, lo que dañaría el motor.
No se olvide de volver a conectar el tubo de agua a la bomba.
Lubrique los cojinetes. Los cojinetes de la rueda y el motor del venti-
lador deben ser lubricados usando unas gotas de un aceite no detergente
de densidad 20/30 una vez al año. No obstante, los motores sin tuberías
para aceite no necesitan ser lubricados. Estos motores son lubricados
en la fábrica de por vida y no requieren nunca ninguna lubricación.
PRECAUCIÓN: No lubrique demás. El agregar demasiado aceite
puede ocasionar que se queme el motor, a causa del aceite entrando al
interior del motor.
Compruebe la tensión de la
banda. Una fuerza de 3 libras
debe desviar la banda 3/4 pulgadas
(véase g. 13). Ajuste la banda si
es necesario.
Compruebe la válvula de desahogo para veri car que no está
obstruida.
Preparar La Unidad Para El Invierno
Drene el agua. Drene siempre toda el agua de la unidad y del tubo de
abastecimiento de agua cuando no use el enfriador durante períodos
prolongados, especialmente al n de la temporada. El tubo debe que-
darse desconectado del enfriador y del abastecimiento de agua para que
no lo congele.
Desconecte el motor y la bomba. Cuando no se utiliza el enfriador
por períodos extendidos, desconecte el motor y la bomba dentro del
enfriador.
Cubra la unidad. Para proteger y alargar la vida útil del acabado,
se sugiere cubrir el enfriador durante períodos largos cuando no sea
utilizado.
Si usted sigue estas sugerencias en cuanto a instalación, operación y mante-
nimiento, podrá disfrutar de muchos años de servicio e ciente y satisfactorio
de este enfriador. Si desea más información, su concesionario tendrá mucho
gusto en ayudarle con respecto a cualquier duda o pregunta.
de conductos. Es importante que la polea del motor sea ajustada al tamaño
correcto para asegurar el máximo rendimiento sin dañar el motor. Siga
cuidadosamente estas instrucciones.
Ajuste la polea del motor. Después de instalar el enfriador completo,
ajuste la polea al diámetro mínimo y ajuste la tensión de la correa. Vea
la sección de mantenimiento para ajustar la tensión de la correa.
Poner en marcha la unidad. Instale todas las rejas con los ltros,
prenda la bomba y permita que siga funcionando hasta que todos los
ltros estén mojados.
Revise el amperio. Con los ltros mojados y la unidad en funciona-
miento, revise el amperio del motor con un medidor de amperio.
Ajuste la polea si es necessario. Si la lectura de amperio es menos
del valor especi cado del motor, apague la unidad y quite la reja con
el ltro. Desconecte el motor dentro de la caja para protegerse en caso
de que alguien intente poner en marcha el enfriador mientras usted está
trabajando. Esto hay que hacerlo por su propia seguridad. Ajuste la
polea a un diámetro mas grande y vuelva
a ajustar la tensión de la banda. Conecte
el motor, coloque la reja y compruebe de
nuevo el amperio. Repita estos pasos hasta
obtener la lectura de amperio correcta. El
incrementar el diámetro de la polea, incre-
menta también el amperio; el disminuir el
diámetro de la polea, disminuye también el
amperio (véase g. 11).
PRECAUCIÓN: No permita que funcione esta unidad si toma
mas amperio del que se indica la placa del motor.
NOTA: No se debe intentar la instalación completa de esta unidad sin la
ayuda de un electricista o alguien que sepa medir el amperio. Si usted no
sigue esta instrucción, podrá ser anulada su garantía.
Mantenimiento
ADVERTENCIA: Antes de hacer cualquier mantenimiento,
compruebe que la corriente esté apagada. Al quitar una reja,
desconecte el motor y la bomba dentro de la caja. Esto es por
su seguridad.
Puesta En Marcha En La Primavera
Cambie los ltros. Debe cambiar los ltros de paja una o dos veces
durante cada temporada, según la duración de ésta. Al principio y a
mediados de la temporada, un ltro limpio es más absorbente y e ciente
y producirá un mayor volumen de aire frío.
Limpie la bomba. Es necesario limpiar la bomba una vez al principio
de cada año. Por su propia seguridad, apague la unidad y desconecte el
Esquemas Del Cableado
240 Voltios120 Voltios
Común
A
Interruptor
Bomba
Motor Del
Ventilador
Rojo
Naranja
Verde
Negro
Tierra
Común
Bajo
Alto
= Empalme De Plástico
Tierra
Bajo
Alto
Bomba
Negro
Rojo
Blanco
Naranja
Verde
Verde
Naranja
Marrón
Blanco
Azul/Negro
Disminuir
Amperio
Fig. 11
Fig. 13
3 Libras
3/4 Pulgadas
Azul/Negro
Blanco
Marrón
Naranja
Verde
Verde
Naranja
Blanco
Rojo
Negro
Bomba
Alto
Bajo
Común
Tierra
= Empalme De Plástico
Alto
Bajo
Común
Tierra
Negro
Verde
Blanco
Rojo
Motor Del
Ventilador
Bomba
A
Interruptor
hélice
Quite
La Base
Fig. 12
12
110503-1
No arranca o
no sale aire
Sale poco
aire cuando
la unidad
está funcio-
nando
Enfriamiento
inadecuado
Garantía Limitada
La presente garantía se extiende al comprador original de un enfriador evaporativo instalado y utilizado bajo condiciones normales. No cubre daños ocurridos
por accidente, descuido o abuso por parte del propietario. No autorizamos que ninguna otra persona o representante asuma por nosotros cualquier otra o
diferente responsabilidad en relación con este producto.
Términos y Condiciones De La Garantía
Durante Ocho Años a partir de la fecha de compra, nosotros reemplazaremos la base original del enfriador en caso de que goteara agua debido a oxidación.
Durante Un Año a partir de la fecha de compra, reemplazaremos cualquier componente original proporcionado por Champion Cooler que falle debido a
cualquier defecto de material o mano de obra en la fábrica solamente.
Exclusiones De La Garantía
No somos responsables por reemplazar los ltros del enfriador. Estos son componentes desechables y deben cambiarse periódicamente. No somos respon-
sables por daños que resulten a consecuencia de alguna falla de funcionamiento.
No somos responsables por cualquier daño producido por el uso de suavizadores de agua, productos químicos, materiales desincrustantes, envolturas de
plástico, o si se usa en esta unidad un motor de mayor potencia de la que se indica en la placa de número de serie.
No somos responsables por el costo del servicio para diagnosticar la causa del problema ni por la mano de obra necesaria para reparar y/o reemplazar pie-
zas.
Como Obtener Servicio Bajo Esta Garantía
Póngase en contacto con el concesionario que le vendió el enfriador. Si por alguna razón usted no queda satisfecho con la respuesta por parte del Concesio-
nario, comuníquese con el departamento de servicio al cliente: 5800 Murray Street, Little Rock, Arkansas 72209.
1-800-643-8341. Correo electrónico: info@championcooler.com.
Esta garantía limitada se aplica al comprador original solamente.
1. No llega corriente
• Fusible fundido
• Cortacircuito desactivado
• Cable eléctrico dañado
2. Banda muy oja o
apretada
3. Motor recalentado
• Banda muy apretada
• Cojinetes de la rueda
están secos
• Diámetro de la polea del
motor demasiado grande
4. Motor parado
1. Insu ciente abertura para
que salga el aire
2. Poca tensión en la banda
3. Filtros obstruidos
4. Agua insu ciente en los
ltros
1. El agotamiento del aire es
inadecuado
2. Los ltros no están
mojados
• Filtros obstruidos
• Filtros agujereados
• Agujeros de los canales
obstruidos
• Bomba no funciona
1. Revise la corriente
• Cambie el fusible
• Restablecer el cortacir-
cuito
• Reemplace el cable
2. Ajuste la tensión de la
banda
3. Determine la causa
• Ajuste la tensión de la
banda
• Lubrique los cojinetes
• Ajústela al diámetro
correcto
4. Cambie el motor
1. Abra las ventanas o las
puertas para aumentar el
ujo de aire
2. Ajuste la tensión o cam-
bie la banda
3. Cambie los ltros
4. Limpie el sistema de dis-
tribución y los agujeros
del canal
1. Abra más las ventanas o
puertas
2. Revise la distribución
de agua
• Cambie los ltros
• Acomode la paja en el
ltro
• Límpielos
• Cámbiela o límpiela
(Desconecte la unidad)
Problema Causa Posible Remedio
La Localización De Averías
Problema Causa Posible Remedio
Motor se apaga
y se enciende
Hace Ruido
Demasiada
humedad en la
casa
Olor a ence-
rrado, olor
desagradable
El agua está
drenando sobre
el tejado.
1. Voltaje de ciente
2. Demasiada tensión en la
banda
3. Eje del ventilador
atorado
4. Cojinetes secos
5. Diámetro de la polea del
motor demasiado grande
dando por resultado
sobrecarga del motor
1. Cojinetes secos
2. Rueda roza contra caja
de la rueda
3. Partes sueltas
1. Insu ciente salida de aire
1. Agua estancado en la
unidad
2. Los ltros tienen moho o
son obstruidos.
3. Los ltros son secos
• Agujeros del canal
tapados
• Bomba no trabaja ade-
cuada
1. El otador no se ajusta
correctamente
2. El montaje de desagüe se
está escapando
1. Compruebe el voltaje
2. Ajuste la tensión de la
banda
3. Lubrique o cambie los
cojinetes (Desconecte la
unidad)
4. Lubrique los cojinetes
5. Ajuste la polea para no
exceder el grado a carga
plena del amperio del
motor
1. Lubrique los cojinetes
2. Inspeccione y alinee
(Desconecte la unidad)
3. Apriételas
1. Abra las puertas o las
ventanas
1. Desagüe y limpie los
ltros
2. Cambie los ltros
3. Revise la distribución
de agua
• Límpielos
• Reemplace o limpie la
bomba (Desconecte la
unidad)
1. Ajuste el otador
2. Apriete la tuerca y el
tubo de desagüe
Registre su producto en línea a: www.championcooler.com/index.php/cooler-warranty-registration
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Essick Air Products 5000 SD Manual de usuario

Tipo
Manual de usuario

En otros idiomas