Goldstar WG6007R El manual del propietario

Categoría
Acondicionadores de aire de sistema dividido
Tipo
El manual del propietario
2 Room Air Conditioner
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find the numbers on a label on the side of the
product.
Dealer's Name
Date Purchased
Staple your receipt to this page in the event you need it
to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and
maintain your air conditioner properly.Just a little preventive
care on your part can save you a great deal of time and
money over the life of your air conditioner.
You'll find many answers to common problems in the chart
of troubleshooting tips.If you review our chart of
Troubleshooting Tips first, you may not need to call for
service at all.
PRECAUTION
Contact an Authorized Service Center for repair or
maintenance of this unit. Call 1-800-243-0000 to
locate the nearest ASC.
This air conditioner is not intended for use by young
children or invalids without supervision.
Young children should be supervised to ensure that
they do not play with the air conditioner.
If the power cord requires replacement, have an
Authorized Servicer install an exact replacement part.
Installation work must be performed in accordance
with the National Electric Code by qualified and
authorized personnel only.
Safety Precautions..........................3
Before Operation.............................7
Introduction ....................................8
Symbols Used in this Manual ........8
Features ........................................8
Electrical Safety ..............................9
Temporary Use of an
Adapter ........................................10
Temporary Use of an
Extension Cord ............................10
Installation ....................................11
Window Requirements ................11
Size ...........................................11
Clearance .................................12
Preparation of Chassis ...............13
Unit Installation ............................14
Operating Instructions .................16
Location and Function
of Controls....................................16
Remote Control Operations ........17
Remote Controller .......................18
Additional Features.......................19
Air Direction ..............................19
Drain Pipe..................................19
Removal from Window...............19
Maintenance and Service ............20
Air Filter ....................................20
Cleaning the Air Conditioner .....20
How to Remove the
Front Grille ................................21
Common Problems and
Solutions.......................................22
Troubleshooting............................23
Window-Type Air Conditioner Owner’s Manual
TABLE OF CONTENTS
Owner’s Manual 3
H
S
I
L
G
NE
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness
is classified by the following indications.
Because of the weight of the product, it is recommended that you have a helper to assist in
the
installation.
Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property only.
WARNING
Installation
ni
l
os
aG
Always install the expansion panel(s).
Improper assembly or installation may cause
incorrect
operation, including injury, fire, and
poor performance elect
ric shock hazards.
Do not place the power cord near a heater.
It may cause fire and electric shock.
Do not use the power cord near flammable
gas
or combustibles such as gasoline,
ben
zene, thinner, etc.
It may cause explosion or fire.
Do not disassemble or modify products.
It may cause failure and electric shock.
Be sure not to do.
Be
sure to follow the instruction.
Safety Precautions
4 Room Air Conditioner
Safety Precautions
Operation
Plug in the power plug
properly.
Otherwise, it will cause
electric shock or fire due to
heat generation or electric
shock.
Do not operate or stop the
unit by inserting or pulling
out the power plug.
It will cause electric shock or
fire due to heat generation.
Do not damage or use an
unspecified power cord.
It will cause electric shock or
fire.
Do not modify power cord
length.
It will cause electric shock or
fire due to heat generation.
Use the air conditioner on a
single outlet circuit. (See page 7.)
Do not share the outlet with
other appliances.
It will cause electric shock or
fire due to heat generation.
Always plug into a
grounded outlet.
No grounding may cause
electric shock (See Installation
Manual).
ON
Unplug the unit if strange
sounds, odors, or smoke
come from it.
Otherwise it may cause fire
and electric shock accident.
Do not use the socket if it is
loose or damaged.
It may cause fire and electric
shock.
Do not operate with wet
hands or in damp
environment.
It will cause electric shock.
Owners Manual 5
H
S
I
L
G
NE
CAUTION
Installation
Safety Precautions
Do not allow water to run
into
electric parts.
It will cause failure of machine
or elect
ric shock.
Leave the door closed while
the
air conditioner is
running.
It is not designed to cool the
entire
house.
Do not operate the
air
conditioner if you
smell gas.
It may cause explosion, fire,
and
burn.
Never touch the metal parts
of
the unit when removing
the
filter.
They are sharp and may
cause
injury.
Do not block the inlet or
outlet.
It may cause failure of
appliance
or accident.
Ensure that the outer case
is
not damaged by age or
wea
r.
If the outer case is damaged,
it
must be repaired or
replaced
immediately.
Le
aving it damaged could
result
in the air conditioner
falling out of the window,
creating
a safety hazard.
Be cautious not to touch the
sharp
edges when
installing.
It may cause injury.
Hold the plug by the head
when
taking it out.
It may cause electric shock
and
damage.
Unplug the air conditioner if
it
will not be used for a long
period.
Prevent accidental startup and
the
possibility of injury.
Sharp
edges
Operation
6 Room Air Conditioner
Safety Precautions
Do not place heavy object
on
the power cord and take
care
so that the cord should
not
be pressed.
There is danger of fire or
elect
ric shock.
If water enters the product,
turn
off the the power switch
of
the main body of appliance.
Contact
service center after
taking
the power-plug out from
the
socket.
Do not clean the air
conditioner
with water.
Water may enter the unit and
degrade
the insulation. It may
cause
an electric shock.
Unplug the air conditioner
be
fore cleaning it.
Since the fan rotates at high
speed
during operation, it may
cause
injury.
Do not put a pet or house
plant
where it will be
exposed to direct air flow.
(Don't
sit in the draft.)
This could injure the pet or
plant.
Do not use this appliance
for special purposes such
as cooling pets
, foods,
precision, machinery, or
objects of art.
It is an air conditioner, not a
precision
refrigeration system.
Always insert the filter
secure
ly.
Clean
it every two weeks.
Operation without filters will
cause failure.
Use a soft cloth to clean. Do
not
use wax, thinner, or a
st
rong detergent.
The appearance of the air
conditioner
may deteriorate,
change
color, or develop
sur
face flaws.
Do not drink water drained
from air conditioner. Do not
direct
airflow at room
occupants
only.
It contains containments and
will
make you sick. This could
damage
your health.
Owners Manual 7
ENGLISH
Before to Operation
1. Plug in the power cord properly.
2. Use a dedicated circuit. Overloading the line could create a fire hazard.
3. Do not use an extension cord. See page 10 for more details.
4. Do not start/stop operation by plugging/unplugging the power cord.
5. If the power cord is damaged and requires replacement, have an Authorized
Servicer install an exact replacement part.
1. Being exposed to direct airflow for an extended period of time could be
hazardous to your health. Do not expose occupants, pets, or plants to direct
airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used
together with stoves or other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g.
preserving precision devices, food, pets, plants, and art objects). Such usage
could damage the items.
4.The air conditioner is a consumer comfort appliance, not a precision climate
control system.
1. Do not touch the metal parts of the unit when removing the filter. Injuries can
occur when handling sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can
destroy the insulation, leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned
off.The fan rotates at a very high speed during operation.There is a
possibility of injury if the units power is accidentally triggered on while
cleaning inner parts of the unit.
For repair and maintenance, contact an Authorized Service Center. See the
warranty page for details or call (800) 243-0000. Have your model number and
serial number available.They should be written on page 2 of this manual.
Before Operation
Preparing for Operation
Usage
Cleaning and Maintenance
Service
Owners Manual 11
ENGLISH
Size
This room air conditioner is
designed for installation in standard
double-hung windows with actual
opening widths from 22" to 36".
The upper and lower window sash
must open sufficiently to allow a
clear vertical opening of 13" from the
bottom of the upper sash to the
window stool.
WARNING:This product is a WINDOW AIR CONDITIONER.
As such, a standard single-hung or double-hung window is required
for proper installation. Non-window installations, including using
sleeves, holes in walls, and other installations are not recommended.
Have the following tools available for installation:
* Screwdriver (Slotted and Phillips) * Ruler
* Knife * Hammer
* Pencil * Level
Installation
Type B: 5 EA
(Wood Screw)
Type A: 11 EA
(Short Screw)
Type C: 3 EA
(
L
Bracket)
Type E: 1 EA
(Sash Seal)
(Not adhesive backed)
Type D: 1 EA
(Seal Strip)
(Adhesive backed)
Type F: 2 EA
(Guide Panel)
Type G: 1 EA
(Support Bracket)
10mm
16mm
13" min
22" to 36"
Installation
Window Requirements
12 Room Air Conditioner
Installation
Clearance
Proper clearance enhances the cooling efficiency of the unit and prevents heat
radiation of the condenser.
1. If a storm window presents interference, fasten a 2" wide wood strip to the inner
window sill across the full width of the sill.The wood strip should be thick
enough to raise the height of the window sill so that the unit can be installed
without interference by the storm window frame.
2. See Figure. B.The top of the wood strip should be approximately
3
/4" higher
than the storm window frame (Storm Window Frame) or wood strip (Outdoors)
to help condensation to drain properly to the outside.
3. Install a second wood strip (approximately 6" long by 1
1
/2" wide and same
thickness as first strip) in the center of the sill flush against the back off the
inner sill.This will raise the L bracket as shown Figure. B.
4. If the distance between Storm Window Frame and Wood Strip Mounted on Top
of Inner Sill is more than 1", two of wood strips are not necessary.
OutdoorsIndoors
Inner Sill
Outer Sill
Inner Sill
Wood Strip Mounted
on Top of Inner Sill
Wood Strip for
L Bracket
3
/4"
Clearance
1" Max.
Storm
Window
Frame
Outdoors
Indoors
Outer Sill
Figure. A Figure. B
Owners Manual 13
ENGLISH
Installation
Preparation of Chassis
1. Insert the guide panels into the guides
of the air conditioner. Fasten the
curtains to the unit with screws
(Type A).
: Use a long screwdriver and
installing the screws will be easier.
2. Cut the adhesive-backed seal strip
(Type D) to the window width.
Remove the backing from the seal
strip and attach the seal strip to the
underside of the bottom window.
3. Locating unit in window
Open the window and mark center line
on the center of the inner sill.
4. Attach L bracket
4-1. Install the L brackets behind the
inner window sill, with short side of
bracket as shown. Use the 2 screws
(Type A) provided.
4-2.The bracket helps to hold unit
securely in place. Be sure to place
bracket edge flush against back of
inner sill.
Tip!
Type A
Type A
Seal Strip
(Type D)
Room Side
Center Line
Inner Sill
Outside
Inside
L
Bracket
Outer Sill
Inner Sill
Type A
8"
8"
Center Line
14 Room Air Conditioner
Installation
Unit Installation
Caution: During the following step, hold unit firmly until window sash
is lowered to top channel behind side panel frames. Personal injury or
property damage may result if unit falls from window.
1. Install the air conditioner in the window
1-1. Carefully lift the air conditioner and
slide it into the open window. Make
sure the bottom guide of the air
conditioner drops into the notches of
the L bracket.
: When the air conditioner drops
into the L bracket, the air conditioner
will be centered in window opening.
1-2.While steadying the air conditioner,
carefully bring the window sash
down behind the upper guide of the
air conditioner.
When the air conditioner is properly
installed, it should tilt slightly down at
the back. If it is set correctly in the
window, it will hang lower in the back
automatically. If it does not, there is a
problem with the installation.
2. Secure the guide panels
Extend the guide panels (Type F) to
fill the window opening using 4
screws (Type B) to secure them.
3.
Install the sash seal and sash lock
3-1. Cut the sash seal (Type E) to the
window width. Stuff the sash seal
between the glass and the window
to prevent air and insects from
getting into the room.
3-2. Fasten the
L bracket using a screw
(Type A).
3-3. Remove the screws that secure the
cabinet and base pan in the right
side.
Tip!
Center Line
Seal
Window Frame
Bottom
Guide
About
1
/
4
"
L
Bracket
Upper Guide
Type B
Sash Seal
(Type E)
L Bracket
Type A
Owners Manual 15
ENGLISH
Installation
3-4. Fasten the support bracket (Type G)
using a screw removed from the air
conditioner cabinet. Attach the
support bracket (Type G) to the inner
window sill with a screw (Type B).
4.
Window installation of room air conditioner is now completed.
See ELECTRICAL DATA for attaching power cord to electrical outlet.
Type B
Support Bracket (Type G)
16 Room Air Conditioner
CAUTION: If you turn off the air conditioner or switch from cooling to
the fan, wait at least 3 minutes before setting to cooling again.
FOR NORMAL COOLING
1.Turn the operation switch to the High Cool or the Low Cool setting.
2. Set the thermostat control to the desired temperature mark (the mid-point is a
good starting position). If the room temperature is not satisfactory after a
reasonable time, adjust the control to a cooler or warmer setting, as
appropriate.
FOR MAXIMUM COOLING
1.Turn the operation switch to the High Cool setting.
2. Set the thermostat control to the largest temperature mark.
FOR QUIETER OPERATION
1.Turn the operation switch to the Low Cool setting.
2. Set the thermostat control as needed.
Operating Instructions
Operation
High
Fan
Low
Fan
High
Cool
Off
Low
Cool
Thermostat
1
2
3
4
5
6
7
8
9
Operating Instructions
Location and Function of Controls
Off - Turns air conditioner off.
High Fan - High speed fan operation without cooling.
Low Fan - Low speed fan operation without cooling.
High Cool - Cooling with high speed fan operation.
Low Cool - Cooling with low speed fan operation.
This automatically controls the temperature of the indoor air.
Turn the knob so that arrow points to the larger marks for greater
cooling. Point the arrow to the smaller marks for more moderate
cooling.
(i.e. the higher the number, the greater the cooling)
18 Room Air Conditioner
Operating Instructions
CAUTION:The Remote Controller will not function properly if strong
light strikes the sensor window of the air conditioner or if there are
obstacles between the Remote Controller and the air conditioner.
How to Insert Batteries
Auto
Swing
Power
Temp
Fan Speed
Timer Mode
Energy
Saver
Temperature Setting
Energy Saver
The fan stops when the compressor stops cooling.
Approximately every 3 minutes the fan will turn on and
check the room air to determine if cooling is needed.
Fan Speed
Power
To turn the Set ON, push the button. To turn the Set OFF, push the button again.
This button takes priority over any other buttons.
When you first turn it on, the Set is on the High cool mode and the temp. at 72°F
Cool/Fan/Dry
Everytime you push this button, it will toggle between COOL, FAN, and DRY.
On/Off Timer
- Stopping Operation
- Starting Operation
This button controls the room temperature setting in a range between
60°F and 86°F in 1° increments.
Each press of the button cycles through the options in this order:
1 Hour 2 Hours 3 Hours 4 Hours 5 Hours 6 Hours 7 Hours
8 Hours 9 Hours 10 Hours 11 Hours 12 Hours CANCLE.
The set temperature will be raised by 2°F after 30 minutes and
again after another 30 minutes.
Each press of the button cycles through the options in this order:
1 Hour 2 Hours 3 Hours 4 Hours 5 Hours 6 Hours
7 Hours 8 Hours 9 Hours 10 Hours 11 Hours 12 Hours
CANCLE.
Pressing the Fan Speed button toggles between Low and
High speeds.
1. Remove the cover from the back of the remote
controller
2. Insert two batteries.
Be sure of the polarity when installing the
batteries.
Be sure that both batteries are new.
3. Re-attach the cover.
Do not use rechargeable
batteries. Such batteries
differ from standard dry cells
in shape, dimensions, and
performance.
Remove the batteries from
the remote controller if the air
conditioner is not going to be
used for an extended length
of time.
Remote Controller
Owners Manual 19
ENGLISH
Air Direction
Adjusting the air direction using the
horizontal air deflector control.
Using the control tabs, the air flow can
be directed to the left, right, straight
ahead, or any combination of these
directions.
Drain Pipe
In humid weather, excess water may
cause the Base Pan to overflow.To
drain the water, remove the Drain Cap
and secure the Drain Pipe to the rear
hole of the Base Pan.
Press the drain pipe into the hole by
pushing down and away from the fins
to avoid injury.
This air conditioner is equipped with a
slinger fan. (See drawing, below.)
The fan has an outer ring that runs in
the water that collects in the base pan
if it gets deep.That condensate is then
picked up by the fan and expelled
through the condenser, making the air
conditioner more efficient.
CAUTION: Be careful when inserting the drain pipe. Push away from
the sharp fin area to avoid slipping injuring yourself.
Removal From Window
Turn the air conditioner off, disconnect the power cord, remove the L bracket, the
screws and Support Bracket installed through the top and bottom of the guide
panels, and save for reinstallation later. Close the guide panels. Keeping a firm grip
on the air conditioner, raise the sash, and carefully tilt the air conditioner backward,
draining any condensate. Lift the air conditioner from the window and remove the
sash seal from between the windows.
Be sure to drain ALL condensate from the air conditioner. If you don't, it could run
out while you carry the unit, making a mess and creating a slipping hazard. This
simple step will save you much cleaning and make a safer work environment.
Operating Instructions
Drain Pipe
Drain Cap
Ring
Additional Features
20 Room Air Conditioner
Air Filter
Check the air filter at least twice a month to see if cleaning is necessary. Trapped
particles in the filter can build up and block the airflow, reducing cooling capacity
and causing an accumulation of frost on the evaporator.To clean the air filter:
1. Lift the inlet grille.
2. Remove the air filter from the front grille by pulling the air filter up slightly.
3. Wash the filter using lukewarm water below 40 °C (104 °F).
4. Gently shake the excess water from the filter and replace.
Cleaning The Air Conditioner
The front grille and Inlet grille may be
wiped with a cloth dampened in a mild
detergent solution.
The cabinet may be washed with mild
soap or detergent and lukewarm
water, then polished with Liquid Wax
for Appliances.
To ensure continued peak efficiency,
the condenser coils (outside of unit)
should be checked periodically and
cleaned if clogged with soot or dirt
from the atmosphere.
Maintenance and Service
Do not force
open or open to far.
Maintenance and Service
Owners Manual 21
ENGLISH
Maintenance and Service
3. Push the grille up from the bottom and
pull the top of the grille away from the
case as the top tabs lift out of their
slots.
1. Remove the thermostat knob and
the operation knob by pulling.
2. Remove the screw securing the
Front Grille.
1. Pull the inlet grille forward
2. Remove the screw securing the
Front Grille.
How to Remove the Front Grille
22 Room Air Conditioner
Maintenance and Service
Before calling for service, please review the following list of common
problems and solutions.
The air conditioner is operating normally when:
You hear a pinging noise.This is caused by water being picked up by the fan on
rainy days or in highly humid conditions.This feature is designed to help remove
moisture in the air and improve cooling efficiency.
See the section on Slinger Fan, page 19.
You hear the thermostat click.This is caused by the compressor cycle starting
and stopping.
You see water dripping from the rear of the unit. Water may be collected in the
base pan in highly humid conditions or on rainy days.This water overflows and
drips from the rear of the unit.
You hear the fan running while the compressor is silent.This is a normal
operational feature.
Common Problems and Solutions
Before Calling for Service
If you have problems with your air conditioner, read the following information and
try to solve the problem. If you cannot find a solution, turn off the air conditioner
and contact your dealer.
Air conditioner does not operate
1. Ensure that the air conditioner is plugged into a proper outlet.
2. Check the fuse or circuit breaker.
3. Check whether the voltage is unusually high or low.
Air does not feel cold enough on the cooling setting
1. Ensure that the temperature settings are correct.
2. Check to see if the air filter is clogged with dust. If so, clean the filter.
3. Ensure that the air flow from the outside is not obstructed and that there is a
clearance of over 20" between the back of the air conditioner and the wall or
fence behind it.
4. Close all doors and windows and check for any source of heat in the room.
24 Room Air Conditioner
Manual del Propietario 25
ESPAÑOL
PARA SUS ARCHIVOS
Escriba aquí el modelo y número de serie:
Modelo n°:
Serie n°:
Puede encontrar los números en la etiqueta de la parte
lateral del producto.
Nombre del distribuidor:
Fecha de compra:
Adjunte su recibo a esta página con la grapadora para
el momento que lo necesite para probar la fecha de su
adquisición o para la validación de la garantía.
LEA ESTE MANUAL
En su interior encontrará muchos consejos útiles sobre la
utilización y mantenimiento de su acondicionador de aire.
Unos pocos cuidados por su parte le pueden ahorrar
mucho tiempo y dinero durante la vida de su
acondicionador de aire.
En la tabla de consejos para la solución rápida de
problemas encontrará muchas respuestas a los problemas
más habituales. Si revisa primero nuestra
Tabla de
Consejos
para la solución rápida de problemas, tal vez no
necesite llamar nunca al servicio técnico.
PRECAUCIÓN
Contacte a un Centro de Servicio Autorizado para reparar o
realizar el mantenimiento de esta unidad. Llame a 1-800-243-0000
para ubicar el CSA más cercano.
El aire acondicionado no es apto para ser usado por niños
pequeños o discapacitados sin la supervision adecuada.
Los niños pequeños deben ser supervisados para asegurar que
no jueguen con el aire acondicionado.
Si hay que cambiar el cable de alimentación, solicite a un técnico
de servicio que instale un recambio exacto.
El trabajo de la instalación debe ser realizado de acuerdo al
Código Eléctrico Nacional, únicamente por el personal calificado y
autorizado.
Precauciones de Seguridad.........26
Antes da poner en marcha...........30
Introducción ..................................31
Símbolos Utilizados en
Este Manual. ................................31
Características ............................31
Seguridad Eléctrica ......................32
Uso Transitorio de un
Adaptador.....................................33
Uso Temporal de un
Cable Alargador ..........................33
Instalación ....................................34
Requerimientos de Ventana ........34
Tamaño .....................................34
Espacio Libre ............................35
Preparación de la Carcasa ..........36
Instalación de la Unidad ..............37
Instrucciones de
Funcionamiento.............................39
Localización y Función de los
Controles .....................................39
Instruccions de Control
Remoto ........................................40
Control Remoto ...........................41
Adicionales e Características.......42
La Dirección del Aire ................42
Tubo de Desagüe .....................42
Removerlo de la Ventana .........42
Mantenimiento y Servicio.............43
Filtro de Aire .............................43
Limpieza del Aire
Acondicionado ..........................43
Como Remover la Parilla
Frontal .......................................44
Problemas y Soluciones
Habituales.....................................45
Resolución de problemas.............46
Manual del usuario del acondicionador de aire tipo Ventana
TABLA DE CONTENIDOS
26 Aire Acondicionador
Precauciones de Seguridad
ADVERTENCIA
Para prevenir tanto lesiones al usuario u otras personas como daños materiales, es preciso
seguir estas instrucciones.
La incorrecta operación del aparato como consecuencia de ignorar las instrucciones
provocará daños o lesiones.
A cause del peso pesado del producto, se recomienda que usted tenga a un ayudante a
participa en la instalación.
El significado de los símbolos utilizados en este manual se indica a continuación.
ADVERTENCIA
PRECAUCION
Este símbolo indica la posibilidad de lesiones mortales o graves.
Este símbolo indica la posibilidad de lesiones o daños materi-ales.
Asegúrese de no hacerlo.
Asegúrese de seguir las instrucciones.
Instalación
Gasolin
Instale siempre el (los) panel(es) de
expansion.
Un montaje o instalación defectuoso puede
provocar un funcionamiento incorrecto,
incluyendo riesgos de lesiones, incendios o
descargas eléctricas.
No coloque el cable eléctrico cerca de un
calefactor.
Puede causar incendio y descarga eléctrica.
No use el cable de corriente cerca de gas
inflamable o combustibles tales como gasolina,
benzina, solvente, etc.
Puede causar explosión o incendio.
No desarme o modifique los productos.
Puede causar fallos y descarga eléctrica.
Precauciones de Seguridad
Manual del Propietario 27
ESPAÑOL
Precauciones de Seguridad
Funcionamiento
Enchufe la corriente
adecuadamente.
De otro modo, causará
descarga eléctrica o incendio
debido a la generación de
calor.
No haga funcionar o detenga
la unidad insertando o
tirando del enchufe.
Causará descarga eléctrica o
incendio debido a la
generación de calor.
No dañe ni use un cable no
especificado.
Causará descarga eléctrica o
incendio.
No modifique la longitud del
cable de corriente eléctrica.
Causará descarga eléctrica o
incendio debido a la
generación de calor.
Use el aparato de aire acondicionado en
un solo circuito. (Consulte la página 7).
No comparta el circuito con otros
electrodomésticos.
Causará descarga eléctrica o
incendio debido a la
generación de calor.
Siempre enchufe las piezas
eléctricas en una salida
conectada a masa.
Si no hay conexión a masa,
se puede producir una
descarga eléctrica. (Vea el
Manual de instalación.)
ON
Desenchufe la unidad si se
producen sonidos u olores
extraños en la unidad.
En caso que no, puede
causar incendio y accidente
de corto circuito.
No use el tomacorriente si
está suelto
o dañado.
Puede causar incendio y
accidente eléctrico.
No haga funcionar la unidad
con las manos húmedas o
en un ambiente húmedo.
Puede causar descarga
eléctrica.
28 Aire Acondicionador
PRECAUCION
Precauciones de Seguridad
Instalación
No permita la entrada de
agua.
Puede causar una falla del
motor o una descarga
eléctrica.
Deje la puerta cerrada
mientras está operando el
aire acondicionado.
Ésta no está diseñado para
enfriar la casa entera.
Ventile antes de hacer
funcionar el acondicionador
de aire cuando sale el gas.
Puede causar explosión,
incendio, quemaduras.
Nunca toque las piezas de
metal de la unidad cuando
quite el filtro.
Son filosas y pueden causar
lesiones.
No bloquee la entrada o la
salida de aire.
Puede causar fallos en la
unidad o accidentes.
Asegúrese de que la caja
externa no está dañada por
los anõs o desgaste.
Si la carcasa exterior está dañada, debe
repararse o recambiarse
inmediatamente. Dejarla podría provocar
que el aparato de acondicionado se
caiga de la ventana, con el consiguiente
peligro de lesiones.
Al momento de su instalación,
evite que se contacte con los
bordes afilados.
Hay riesgo de lesiones
personales.
Sostenga el enchufe por el
cuerpo (no del cable)
cuando lo saque.
Puede causar descarga
eléctrica y daño.
Desenchufe el aparato de aire
acondicionado si no va a utilizarlo
durante un largo período de tiempo.
Prevenga un arranque
accidental y la posibilidad de
lesiones.
Bordes
afilados
Funcionamiento
Manual del Propietario 29
ESPAÑOL
Precauciones de Seguridad
No coloque objetos sobre el
cable de corriente y cuide
que el cable no quede
presionado.
Hay peligro de incendio o de
descarga eléctrica.
Si entra agua a la unidad, gire el
interruptor principal del artefacto.
Tome contacto con el centro de
servicio después de desconectar el
enchufe del tomacorriente.
No limpie la unidad de aire
acondicionado con agua.
Puede entrar agua en la
unidad y disminuir la
aislación. Puede causar una
descarga eléctrica.
Desenchufe el aparato de
aire acondicionado antes de
limpiarlo.
Como el ventilador gira a alta
velocidad cuando está funcionando,
puede causar lesiones.
No coloque una mascota o una
planta donde quede expuesto al
flujo directo de aire.
No se siente donde haya
corrientes de aire.
Este puede causar lesiones o
daños en la mascota o la
planta.
No use la unidad para propósitos
especiales tales como animals o
vegetales, máquinas de
precision u objetos de arte.
Puede causar daño a los
animales o vegetales y
pérdida de objetos.
Siempre asegure los filtros
al insertarlos. Límpielos
cada dos semanas.
El funcionamiento sin filtros
puede dañar la unidad.
Use una paño suave para
limpiar. No use ceras,
solventes o un detergente
fuerte
La unidad del aire acondicionado
puede deteriorarse, cambiar de
color, o desarrollar manchas en
la superficie.
No beba el agua drenada del
acondicionador de aire. / No
dirija el flujo de aire sólo a los
ocupantes de la habitación.
Contiene elementos que
pueden ser nocivos para su
salud. / Esto puede dañar su
salud.
Wax
Thinner
30 Aire Acondicionador
Previo al Funcionamiento
1. Coloque el enchufe correctamente.
2. Use un único circuito para este aparato. Recargar el circuito podría provocar
un riesgo de incendios.
3. No utilice un alargador. Consulte la página 10 para más detalles.
4. No arranque/detenga el funcionamiento enchufando/desenchufando el cable
de corriente eléctrica.
5. Si el alargador está dañado y ha de ser recambiado, solicite a un técnico
autorizado que instale un recambio exacto.
1. Estar expuesto al flujo directo de aire por un período largo de tiempo puede
constituir un riesgo para su salud. No exponga a las personas, mascotas o
plantas al flujo directo por períodos largos de tiempo.
2. Debido a la posibilidad de falta de oxígeno, ventile la habitación cuando se
use al mismo tiempo que estufas u otros dispositivos de calefacción.
3. No use este acondicionador de aire para propósitos determinados no
especificados (por ej.: preservar dispositivos de precisión, alimentos,
cachorros, plantas y objetos de arte).Tales usos puede dañar los elementos.
4. El aparato de aire acondicionado es un aparato diseñado para el confort del
consumidor. No es un sistema aclimatizador.
1. No toque las partes de metal de la unidad cuando quite el filtro. Puede
lastimarse cuando manipule bordes filosos de metal.
2. No use agua para limpiar adentro del acondicionador. La exposición al agua
puede destruir la aislación y esto a su vez provocar una descarga eléctrica.
3. Cuando limpie la unidad, asegúrese que la corriente y el interruptor estén
desconectados. El ventilador gira a muy alta velocidad cuando está
funcionando. Existe la posibilidad de lesionarse si la energía se conecta
accidentalmente cuando esté limpiando las piezas internas de la unidad.
Para reparaciones y mantenimiento, póngase en contacto con un centro de
servicio autorizado. Consulte la página de garantía o llame al número (800) 243-
0000.Tenga su númeor d emodelo y número de serie a mano. Los encontrará
en la página 2 de este manual.
Antes de poner en marcha
Preparar para el funcionamiento
Uso
Limpieza y mantenimiento
Servicio
34 Aire Acondicionador
Instalación
10mm
16mm
Tipo B: 5
(Tornillo Mediano)
Tipo A: 11
(Tornillo corto)
Tipo C: 3
(El Paréntesis L)
Tipo E: 1
(Banda del Marco)
(No adhesivo
posterior
)
Tipo D: 1
(Banda Adhesiva)
(Adhesivo posterior)
Tipo F: 2
(Panel Guía)
Tipo G: 1
(Sostenga Paréntesis)
Instalación
Requerimientos de Ventana
Para la instalación debería tener a disposición los instrumentos siguientes:
* Destornillador (Estrella y Phillips) * Regla
* Cucjillo * Martillo
* Lápiz Nivel
Tamaño
Este ventilador de casa está
construido para ventanas estándar de
dos alas con la extensión real de
apertura de 22" a 36". El ala superior
y el inferior de la ventana deben
abrirse lo suficiente para producir un
orificio vertical de 13" desde el ala
superior hasta el antepecho.
Min. 13"
22" a 36"
ADVERTENCIA :
Este producto es un aparato de AIRE ACONDICIONADO
PARA INSTALACIÓN EN VENTANAS. Como tal, se necesita una ventana de
un cuelgue o de doble cuelgue para una instalación adecuada. No se
recomiendan instalaciones en lugares que no sean ventanas, utilizando
casquillos, orificios en las paredes ni cualquier otro tipo.
Manual del Propietario 35
ESPAÑOL
Instalación
Espacio libre
El suficiente espacio libre aumenta la eficiencia de refrigeración de la unidad e
impide la irradiación del calor del condensador.
1. Si la sobre-ventana estorba colóquese una tira de madera de 2 pulg de ancho
a lo largo del descanso de la ventana por la parte que de internamente al
cuarto, y en toda su extensión. La tira de madera debe ser lo suficientemente
gruesa para elevar el descanso de la ventana, de tal manera que la unidad de
aire acondicionado pueda ser intalada sin interferencia del marco de la sobre-
ventana (storm window).
2.Ver Figura. B. La parte superior de la tira de madera debe estar
aproximadamente a
3
/4 de pulg más alta que el marco de la sobre ventana,
(storm window) para ayudar a que el agua de condensación de la unidad fluya
hacia afuera.
3. Instale una segunda tira de madera (aproximadamente 6 pulg. de largo, 1
1
/2
pulg de ancho y mismo espesor que la primeratira de madera) en el centro del
descanso exterior, póngala contra la parte posterior del descanso interior. Esto
elevará la ménsula L como en la Figura. B.
4. Si la distancia entre "Franja de Madera Montada Sobre la Parte superior del
Descanso Interior" y "Tira de Madera Para la Mensula L y Mensula de
Antepecho
Interior
ExteriorInterior
Antepecho
Antepecho
Interior
3/4-Pulg
de Separacion
1" Max.
Ventana de
Hoja Double
Antepecho
ExteriorInterior
Franja de Madera Montada
Sobre la Parte superior del
Descanso Interior
Tira de Madera para la
Mensula L y Mensula
de Antepecho
Figura. A Figura. B
36 Aire Acondicionador
Instalación
Preparación de la Carcasa
1.
Introduzca los paneles en los guías del
aire acondicionado. Las cortinas
atorníllelas con los tornillos (Tipo A).
Use un atornillador largo. Así le
será más fácil instalar los tornillos.
2.
Corte la banda adhesiva (
Tipo
D) y
colóquela del ancho de la ventana.
Remueva el plástico de la banda adhesiva
y colóquela en la parte superior de el
marco inferior de la ventana.
3. Colocando la unidad en la ventana
Abra la ventana y marque LINEA en el
centro esta.
4. Coloque el Ménsula en L
4-1. Instale los soportes L detrás de
alféizar interno de la ventana, con el
lado corto del soporte como está
ilustrado. Utilice 2 tornillos (
Tipo
A)
proveidos.
4-2. La ménsula ayuda a que la unidad
se encuentre firme. Asegúrese de
poner la ménsula en L contra la
parte posterior del descanso interior.
CONSEJO
Tipo A
Tipo A
Banda
Adhesiva
(Tipo D)
Linea del Centro
Taburete
Antepecho
Interior
Exterior
Interior
Ménsula en
L
Descanso
Exterior
Descanso
Interior
Tipo A
8"
8"
Linea del Centro
Manual del Propietario 37
ESPAÑOL
Instalación
Instalación de la Unidad
Precautión: En las siguientes instrucciones, sostenga la unidad firmemente
hasta que la parte corrediza de la ventana descanse sobre la parte superior
del canal y por detrás del marco de los paneles corredizos. Puede haber
lesiones o daños si la unidad se cae de la ventana.
1. Instale el Aire Acondicionado a la
Ventana
1-1.
Cuidadosamente levante el aire
acondicionado y colóquelo en el hoyo
de la ventana. Asegúrese de que la guía
inferior del aire acondicionado caiga en
lugar correcto del ménsula en L.
Cuando el aire acondicionado sea
fijado en el support en L, el aire acondicionado
será centrado como pueden observar.
1-2. Mientras mantiene el aire acondicionado en
posición, cuidadosamente baje el borde de la
ventana superior hasta la guía superior del
aire acondicionado.
Una vez instalado debidamente el aparato de
aire acondicionado, debería inclinarse
ligeramente hacia abajo en su parte posterior.
Si está mal puesto en la ventana, colgará más
abajo por la parte posterior automáticamente.
Si no lo hace, hay una problema con la
instalación.
2. Asegure los Paneles
Extienda los paneles para rellenar los orificios
de la ventana usando los 4 tornillos (Tipo B).
3. Instale la Banda del Marco
3-1. Corte la banda del marco del mismo ancho de
la ventana. Coloque la banda del marco entre
el vidrio y la ventana para prevenir la
penetración al cuarto de insectos y aire.
3-2. Atornille la cerradura del marco usando un
tornillo Tipo A.
3-3. Quite los tornillos que aseguran el gabinete y
cacerola despreciable en el lado correcto.
CONSEJO
Linea del Centro
Banda
Borde de la Ventana Superior
Guía Inferior
Aproxi-
madament 1/4"
Support en L
Guía Superior
Cerradura del Marco
Tipo B
Tipo A
38 Aire Acondicionador
Instalación
3-4. Amarre la escuadra de soporte (Tipo
G) usando un tornillo que puede sacar
del cabinete del aparato de aire
acondicionado. Acople la escuadra
(Tipo G) a la parte interior de la repisa
de la ventana con un tornillo (Tipo B).
4. La instalación del aire acondicionado de ventana no estará completa.Vea
SEGURIDAD ELECTRICA para conectar la extensión eléctrica al toma corriente.
Tipo
B
Sostenga Paréntesis
(
Tipo
G)
Manual del Propietario 39
ESPAÑOL
Si Vd. desconecta el ventilador o lo conmuta del enfriamiento a la
ventilación, antes del nuevo ajuste del enfriamiento espere por lo
menos 3 minutos.
PARA UN ENFRIAMIENTO NORMAL
1. Ponga el botón de operation en High Cool o Low Cool.
2. Ajuste el control del Termostat en la marca deseada(usualmente el punto medio
es un buen punto para comenzar). Si la temperatura del cuarto no es
satifactoria después de un período de tiempo razonable, ajuste el control de
temperatura a una marca más grande (para una temperatura interna más fría)
o a una marca más pequeña (para que la temperatura interna sea menos fría).
PARA UN ENFRIAMIENTO MAXIMO
1. Ponga el botón de operation en la marca más grande.
2. Ponga el control del Termostat en la marcamás grande.
PARA UNA OPERACIÓN SILENCIOSA
1. Ponga el botón de operation en la marca más pequeña.
2. Ponga el termostat en la temperatura interior deseada.
Instrucciones de funcionamiento
Operation
High
Fan
Low
Fan
High
Cool
Off
Low
Cool
Thermostat
1
2
3
4
5
6
7
8
9
Instrucciones de Funcionamiento
Localización y Función de los Controles
Off - Apaga el acondicionador.
High Fan - Permite la velocidad rápida del ventilador.
Low Fan - Permite la velocidad lenta del ventilador.
High Cool - Permite el enfriamiento con el ventilador
en alta velocidad.
Low Cool - Permite el enfriamiento con el ventilador
en baja velocidad.
La temperatura del aire interno será controlada automáticamente.
Mientras más alta sea la marca más frío estará el aire internio.
La temperatura se selecciona posicionando el control en la marca
deseada.
(es decir, a mayor sea el número, mayor será el enfriamiento)
Manual del Propietario 41
ESPAÑOL
Instrucciones de funcionamiento
PRECAUTIÓN: El mando a distancia no funcionará correctamente si
una luz fuerte hace contacto con el sensor del aire acondicionado o si
hay obsáculos entre el mando a distancia y el aire acondicionado.
Auto
Swing
Power
Temp
Fan Speed
Timer Mode
Energy
Saver
Frío/Ventilador/Seco
Cada vez que presione este botón, las palabras COOL, FAN y DRY aparecerán alternadamente.
Enecndido/Apagado
Para ENCENDER el sistema presione el botón, y para APAGARLO presione el botón otra vez.
Este botón tiene prioridad sobre todos los otros botones.
Cuando Ud. Io enciende por primera vez, el sistema está en el y la temperatura es de 72˚F.
Ajuste de la Temperatura
Este botón controla la temperatura de la sala entre los 60°F y los
86°F en incrementos de 1°.
Ahorrador de Energía
El ventilador se detiene cuando el compressor no sigue enfriando.
Aproximadamente cada 3 minutos el ventilador se encenderá,
y necesitará verificar la temperatura del cuarto para saber si
es necesario más enfriamiento.
Marcador de Encendido/Apagado
- Operación de Parada:
- Operación de Iniciación:
Velocidad del Ventilador
Pulsar el botón de velocidad del ventilador hace cambiar las
velocidades entre Low y High.
Con cada pulsación del botón se realiza un ciclo por las opciones
en este orden: 1 hora 2 horas 3 horas 4 horas 5 horas
6 horas 7 horas 8 horas 9 horas 10 horas 11 horas
12 horas CANCEL.
La temperatura fija se elevará 2°F transcurridos 30 minutos y de
nuevo transcurridos otros 30 minutos.
Con cada pulsación del botón se realiza un ciclo por las opciones
en este orden: 1 hora 2 horas 3 horas 4 horas 5 horas
6 horas 7 horas 8 horas 9 horas 10 horas 11 horas
12 horas CANCEL.
1. Quite la tapa de la parte posterior del telemando.
Para ello haga deslizar la tapa según la dirección
del la flecha.
2. Introduzca las dos baterías, Respete siempre la
polaridad al instalar las pilas. Use baterías nuevas.
3.Volver a cerrar, resbalando la tapa hasta la
posición inicial.
No utilice baterís recargables,
éstas son diferentes de forma,
de dimensión y uso respecto a
las baterías secas usuales.
Seque las baterías del
telemando cuando el
acondicionador no vaya a ser
usado durante un largo período.
Cómo Poner las Baterías
Control Remoto
42 Aire Acondicionador
Instrucciones de funcionamiento
La dirección del aire
Para ajustar la direccion del aire usando
control de la direccion del aire.
Las dos lengüetas horizontales para el
control de las rejillas le permiten descargar el
aire hacia la izquierda, o algo de aire a la
izquierda y otro a la derecha, o todo el aire
hacia el frente, o cualquier combinación de
las posiciones mencionadas.
Tubo de Desagüe
En climas húmedos, es posible que la
Bandeja Evaporadora se llenne de agua.
Para quitar el agua acumulado, es
preciso conectar el tubo de desagüe.
Quite la Tapa del Desagüe y conecte el
Tubo a la Bandeja Evaporadora.
Este aparato de aire acondicionado va
equipado con un ventilador de
extracción. (Véase la ilustración de
abajo). El ventilador tiene un anillo
externo que gira en el agua que recoge
en la plancha base al entrar en
profundidad. La condensación la recoge
el ventilador y la expulsa a través del
condensador, haciendo más eficiente al
aparato de aire acondicionado.
PRECAUTIÓN:Tenga cuidado al insertar el tubo de drenaje. Aléjalo de
la area aguda para evitar el deslice y lesiones por usted mismo.
Removerlo de la Ventana
Apague el aire acondicionado, desconecte el cordón eléctrico del toma corriente,
remueva la cerradura del marco y los tornillos instalados en la parte superior e
inferior de los paneles, y guárdelos para reinstalación. Cierre los paneles.
Manteniendo el aire acondicionado fuertemente, levante el marco de la ventana, y
cuidadosamente, incline el aire acondicionado hacia atrás, botando cualquier
agua condensada. Deslice el aire acondicionado 1" a la derecha, luego levántelo
de la ventana y remuévale la banda del marco de la ventana.
Asegúrese de drenar TODO el condensado del aparato de aire acondicionado. Si
no lo hace, podría salirse mientras transporta el aparato, ensuciando, con el
consiguiente peligro de resbalones. Este simple paso le ahorrará tiempo de
Tapa del Desagüe
Tubo
Cuelgue Empujon
Adicionales e Características
Anillo
Manual del Propietario 43
ESPAÑOL
Filtro de Aire
Revise por lo menos dos veces al mes si no es necesario limpiar el filtro de aire.
Las partículas detenidad se pueden acumular en el filtro impidiendo el flujo del
aire, limitando el rendimiento de enfriamiento y causando la acumulación de hielo
en el evaporador. Proceder de la limpieza del filtro de aire:
1. Levante la rejilla de entrada
2. Saque el filtro de aire de la rejilla delantera sacándolo ligeramente hacia arriba.
3. Lave el filtro con agua tibia de temperatura menor de 40°C (104°F).
4. Escurra ligeramente el agua sobrante del filtro y vuelva a instalarlo.
Limpieza del Aire Acondicionado
La parrilla frontal puede ser limpiada con
un trapo húmedo mojado en un
detergente suave.
El gabinete puede ser lavado con jabón
suave o detergente y agua tibia, entonces
pulido Cera Liquida para aparatos.
Para asegurarse una eficiencia continua,
las bobinas del condensador (del lado
expuesto al exterior) debe ser revisado y
lavado periódicamente sea por que se
tranque con basura o polvo de la
atmosférico.
Mantenimiento y servicio
No debe forzar
a abrir o abrir a
lo lejos.
Mantenimiento y servicio
44 Aire Acondicionador
Mantenimiento y servicio
3. Suelte el lado izquierdo primero.
Después cuidadosamente hale
desde la parte de arriba y empuje
hacia la derecha. Las lengüetas
están aseguradas.
1. Saque el Filtro de Aire halando
hacia la izquierda.
2. Saque el tornillo que asegura la
Parrilla Frontal.
1.Tire de la rejilla de entrada hacia
delante agarrando ambas lengüetas
y tire del filtro del aire hasta sacarlo.
2. Saque el tornillo que asegura la
Parrilla Frontal.
Como Remover la Parilla Frontal
Manual del Propietario 45
ESPAÑOL
Mantenimiento y servicio
Antes de llamar al servicio, tenga a bien revisar la siguiente lista de
problemas y sus soluciones.
El acondicionador de aire está funcionando normalmente cuando:
Escucha un sonido metálico. Lo causa el agua que recoge el condensador en
días lluviosos o en condiciones de mucha humedad. Esta característica está
diseñada para ayudar a quitar la humedad en el aire y mejorar la capacidad de
enfriamiento.
Consulte la sección del Ventilador de extracción en la página 19.
Oye un clic en el termostato. Lo causa el ciclo del compresor que comienza y se
detiene.
Ve gotear agua de la parte posterior de la unidad. El agua puede ser recogida
en la bandeja de base en condiciones de mucha humedad o días de lluvia. Esta
agua desborda y gotea desde la parte posterior de la unidad.
Oye funcionar el ventilador mientras el compresor está silencioso. Esto es una
característica operativa normal.
Antes de Llamar el Servicio de Asistencia Técnica
Si tiene problemas con su ventilador, lea las informaciones siguientes y trate de
resolver el problema. Si no puede encontrar la solución, desconecte el ventilador
y diríjase a su suministrador.
El ventilador no funciona
1. Compruebe que el ventilador esté conectado en un enchufe correcto.
2. Revise el fusible.
3. Compruebe que la tensión no sea demasiado alta o baja.
Al ajustarse el enfriamiento, el aire no parece frío lo suficiente
1. Revise si los ajustes de la temperatura son correctos
2. Revise si el filtro de aire no está atascado de polvo. En el caso de que sí,
cambie el filtro.
3. Compruebe que afuera no haya un obstáculo del flujo de aire y si entre la
parte trasera del ventilador y la pared o la barrera haya espacio libre de por lo
menos 1 metro (20").
4. Cierre todas las puertas y ventanas y compruebe que no haya una fuente de
calor en la habitación.
Problemas y Soluciones habituales
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47

Goldstar WG6007R El manual del propietario

Categoría
Acondicionadores de aire de sistema dividido
Tipo
El manual del propietario

en otros idiomas