Hubbell Premise Wiring PD2620 Guía de instalación

Tipo
Guía de instalación
Wiring Device - Kellems
Hubbell Incorporated (Delaware)
Shelton, CT 06484
1-800-288-6000
www.hubbell-wiring.com
NEMA INTERMEDIARY PLATES FOR 4/5 AND 10 GANG FLOOR
BOXES Installation Instructions ENGLISH
PD-2620 11/22
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing or servicing.
NOTICE: For installation by a qualified electrician in accordance with all national and local electrical codes, communications standards, the following
instructions and any instructions included with individual devices.
NOTICE: Ensure data/communications circuits are separated from lighting/power circuits in accordance with the NEC and CE Code requirements.
Use with AFB10G55, AFB10G55CHI, CFB10G55, CFB10G55CR, CFB10G55R, CFB10G55RCR, CFB10G55E, CFB10G55CRE, CFB10G55RE, CFB10G55RCRE,
CFB45G55E, CFB45G55CRE, CFB45G55RE, OR CFB45G55RCRE floor boxes.
1. For 10 GANG boxes, remove and discard wireway spacer [5] from side of box where intermediary plate is to be used, see FIGURE C.
2. For 4/5 GANG boxes, break off and discard the extension from the rectangular filler plate [8], see FIGURE D
3. Remove and discard existing partitions [6] by bending or breaking them out, see FIGURE C and FIGURE D.
4. For 10 GANG boxes, remove filler plate [1] from mounting plate [2], attach the filler plate [1] to the floor box using one #6-32 pan head screws [7],
see FIGURE E. Tighten screw to 9 - 12 lbs-in torque [1.0 - 1.3 N-m].
5. For 4/5 GANG boxes, remove and discard filler plate [1] from mounting plate [2] see FIGURE A.
6. For single service applications, skip to step 9.
7. Mount the low voltage partition [3] to the mounting plate [2] using two #6-32 flat head screws [4], see FIGURE B. Tighten screws to 9 - 12 lbs-in
torque [1.0 - 1.3 N-m].
8. For Catalogs CFB10G55E, CFB10G55CRE, CFB10G55RE, CFB10G55RCRE, CFB45G55E, CFB45G55CRE, CFB45G55RE, OR CFB45G55RCRE, use low
voltage partition [3] as provided, for Catalogs AFB10G55, AFB10G55CHI, CFB10G55, CFB10G55CR, CFB10G55R, CFB10G55RCR, break off and discard
the extension of the low voltage partition [3], see FIGURE B.
9. Attach the mounting plate [2] to the floor box using two #6-32 pan head screws [7], see FIGURE E. Tighten screws to 9 - 12 lbs-in torque [1.0 - 1.3
N-m].
10. Install wiring devices, supplied by others, in accordance with national and local electrical codes, and instructions included with the individual device.
11. Install NEMA style cover plate(s), supplied by others, to complete the installation.
12
4
2
5
7
7
1
AFIGURE B
FIGURE
CFIGURE
EFIGURE
FB10MPNEMA2XG SHOWN
FB10MPNEMA2XG SHOWN
6
3
8
DFIGURE
10 GANG BOX SHOWN 4/5 GANG BOX SHOWN
6
PLAQUES INTERMDIAIRE NEMA POUR BOTES DE PLANCHER 10
COMPARTIMENTS Directives de montage
HUBBELL MXICO garantiza este producto, de estar libre de defectos en materiales y mano de obra por un ao a partir de su compra. Hubbell reparar o reemplazar el artculo
a su juicio en un plazo de 60 das. Esta garanta no cubre desgastes por uso normal o daos ocasionados por accidente, mal uso, abuso o negligencia. El vendedor no otorga otras
garantas y excluye expresamente daos incidentales o consecuenciales inherentes a su uso.
Calle 5 sur No. 104, Parque Industrial Toluca 2000,
Toluca, Edo de Mxico C.P.
50200
HUBBELL PRODUCTS MXlCO S. DE R.L. DE C.V.
Tel.:(722) 980-0600
FRANAIS
PLACAS INTERMEDIARIA NEMA PARA CAJAS DE PISO DE 10
COMPARTIMENTOS - Instrucciones de instalacinESPAOL
ATTENTION - RISQUE DE CHOC LECTRIQUE. Dbrancher le circuit avant de procder au montage ou la maintenance.
AVIS - Doit tre install par un lectricien qualifi conformment aux codes de l'lectricit nationaux et locaux et selon les normes de
communication, les directives suivantes et les directives accompagnant les dispositifs individuels.
AVIS - S'assurer que les circuits de communication/des donnes sont spars des circuits d'alimentation/d'clairage conformment aux
exigences du NECMD et du Code canadien de l'lectricit.
UTILISER AVEC LES BOTES DE PLANCHER AFB10G55, AFB10G55CHI, CFB10G55, CFB10G55CR, CFB10G55R, CFB10G55RCR, CFB10G55E,
CFB10G55CRE, CFB10G55RE, CFB10G55RCRE, CFB45G55E, CFB45G55CRE, CFB45G55RE OU CFB45G55RCRE.
1. Pour les botes 10 compartiments, retirer et jeter la cale du caniveau [5] du ct de la bote o la plaque intermdiaire doit tre
utilise, consulter la FIGURE C.
2. Pour les botes 4/5 compartiments, casser et jeter la rallonge de la plaque de remplissage rectangulaire [8], consulter la FIGURE D.
3. Retirer et jeter les cloisons existantes [6] en les pliant ou en les cassant, consulter la FIGURE C et la FIGURE D.
4. Pour les botes 10 compartiments, retirer la plaque de remplissage [1] de la plaque de montage [2], fixer la plaque de remplissage
[1] la bote de plancher l'aide d'une vis tte cylindrique n 6-32 [7], consulter la FIGURE E. Serrer la vis un couple de 1,0 - 1,3
Nm [9 - 12 lbpo].
5. Pour les botes 4/5 compartiments, retirer et jeter la plaque de remplissage [1] de la plaque de montage [2], consulter la FIGURE
A.
6. Pour les applications un seul service, passer l'tape 9.
7. Fixer la cloison basse tension [3] sur la plaque de montage [2] l'aide de deux vis tte plate n 6-32 [4], consulter la FIGURE B.
Serrer les vis un couple de 1,0 1,3 Nm [9 12 lbpo].
8. Pour les numros de catalogue CFB10G55E, CFB10G55CRE, CFB10G55RE, CFB10G55RCRE, CFB45G55E, CFB45G55CRE, CFB45G55RE
OU CFB45G55RCRE, utiliser la cloison basse tension [3] fournie; pour les numros de catalogue AFB10G55, AFB10G55CHI,
CFB10G55, CFB10G55CR, CFB10G55R, CFB10G55RCR, briser et jeter la rallonge de la cloison basse tension [3], consulter la FIGURE
B.
9. Fixer la plaque de montage [2] la bote de plancher l'aide de deux vis tte cylindrique n 6-32 [7], consulter la FIGURE E. Serrer
les vis un couple de 1,0 1,3 Nm [9 12 lbpo].
10. Installer les dispositifs de cblage, fournis par des tiers, conformment aux codes lectriques nationaux et locaux, et aux directives
fournies avec les dispositifs individuels.
11. Installer le ou les couvercles de type NEMAMD, fournis par des tiers, pour terminer l'installation.
PRECAUCION: RIESGO DE CHOQUE ELECTRICO. Desconecte la fuente de poder antes de instalacin o servicio.
NOTA: Instalacin por personal calificado de acuerdo con las normas nacionales y locales, los estndares de comunicacin, las siguientes
instrucciones y cualquier instruccin es incluida con los dispositivos individuales.
NOTA: Asegrese de que los circuitos de datos/comunicaciones estn separados de los circuitos de iluminacin/alimentacin de
acuerdo con los requisitos NEC y CE.
Usar con AFB10G55, AFB10G55CHI, CFB10G55, CFB10G55CR, CFB10G55R, CFB10G55RCR, CFB10G55E, CFB10G55CRE, CFB10G55RE,
CFB10G55RCRE, CFB45G55E, CFB45G55CRE, CFB45G55RE, o cajas de piso CFB45G55RCRE.
1. Para cajas de 10 MODULOS, retire y deseche el espaciador de la canaleta de cables [5] del lado de la caja donde se usar la placa
intermedia, consulte la FIGURA C.
2. Para cajas de 4/5 MODULOS, rompa y deseche la extensin de la placa de relleno rectangular [8], consulte la FIGURA D
3. Quite y deseche las particiones existentes [6] doblndolas o rompindolas, consulte la FIGURA C y la FIGURA D.
4. Para cajas de 10 MODULOS, retire la placa de relleno [1] de la placa de montaje [2], fije la placa de relleno [1] a la caja de piso usando
un tornillo de cabeza troncocnica #6-32 [7], consulte la FIGURA E. Apriete el tornillo a 9 - 12 lbs-in de torsin [1.0 - 1.3 N-m].
5. Para cajas de 4/5 MODULOS, retire y deseche la placa de relleno [1] de la placa de montaje [2] consulte la FIGURA A.
6. Para aplicaciones de un solo servicio, salte al paso 9.
7. Monte la particin de bajo voltaje [3] en la placa de montaje [2] usando dos tornillos de cabeza plana #6-32 [4], consulte la FIGURA B.
Apriete los tornillos a 9 - 12 lbs-in de torsin [1.0 - 1.3 N-m].
8. Para catlogos CFB10G55E, CFB10G55CRE, CFB10G55RE, CFB10G55RCRE, CFB45G55E, CFB45G55CRE, CFB45G55RE, o
CFB45G55RCRE, use la particin de bajo voltaje [3] como se proporciona, para catlogos AFB10G55, AFB10G55CHI, CFB10G55,
CFB10G55CR, CFB10G55R, CFB10G55RCR, rompa y deseche la extensin de la particin de bajo voltaje [3], consulte la FIGURA B.
9. Fije la placa de montaje [2] a la caja de piso usando dos tornillos de cabeza troncocnica #6-32 [7], consulte la FIGURA E. Apriete los
tornillos a 9 - 12 lbs-in de torsin [1.0 - 1.3 N-m].
10. Instale dispositivos de cableado, suministrados por otros, de acuerdo con los cdigos elctricos nacionales y locales, y las
instrucciones incluidas con el dispositivo individual.
11. Instale la(s) placa(s) de cubierta estilo NEMA, suministradas por otros, para completar la instalacin.
  • Page 1 1