Aethra D2000Pro Manual de usuario

Tipo
Manual de usuario

Este manual también es adecuado para

ENGLISH
GB
ITALIANO
I
FRANÇAIS
F
ESPAÑOL
E
DEUTSCH
D
Quick guide
Guida rapida
Guide rapide
Manual de istrucciones rapide
Handbuch
VX2000
Multiprotocol Interface Option
ENGLISH
GB
VX2000
MULTIPROTOCOL
INTERFACE
D2000PRO OPTION
USER’S MANUAL
The information contained in this document is the
property of Aethra
. It is subject to change without
notice and it shall in no way be blinding for
Aethra
2002 Copyright Aethra S.p.a. All right reserved.
Release 3/2.62 – December 2002
Code 074042002ML
This manual is composed of 18 pages
Quick Guide VX2000
5
GB
Index
1 INTRODUCTION.................................................................................... 7
1.1 OPENING THE MANUAL TEST SCREEN ....................................... 7
1.2 COMMON SETUP ............................................................................. 8
1.3 UNFRAMED BER TEST .................................................................... 10
1.3.1 RUNNING AN UNFRAMED BER TEST...................................... 11
2 SMART STATUS.................................................................................... 13
2.1 V/X INTERFACE STATUS................................................................. 13
3 TECHNICAL SPECIFICATIONS ............................................................ 13
4 FUNCTIONAL SPECIFICATIONS.......................................................... 16
4.1 PIN OUT ............................................................................................ 17
4.2 OPTIONAL CODES........................................................................... 20
Quick Guide VX2000
6
GB
SAFETY RULES
The change from cold to hot environments can cause the formation of
condense inside the device. To avoid malfunctioning, wait at least 2 hours
before connecting the device to the supply mains.
Do not access internal parts of the device (and/or of the power supply unit).
If objects or liquids penetrate inside the device, immediately disconnect the
power supply cable. Before using the device again, have it checked by
specialised staff.
Refer to qualified staff for service.
In case of intervention, always check that the power supply has been
completely and successfully disconnected.
In case of fire, absolutely avoid using water to extinguish it.
WARNINGS
ATTENTION:
Many of the components used in this device are sensitive to
electrostatic charge.
In case of manipulation of the connection cables, disconnect the
power supply and avoid direct contacts with the connector terminals.
When handling electronic components, to eliminate any static
electricity touch a grounded surface. If possible, wear a grounding
armband.
Failure to comply with these warnings could cause permanent
damage to device.
To guarantee continuous protection for operator safety, only use the
mains adapter supplied with the instrument.
Quick Guide VX2000
7
GB
1 INTRODUCTION
With the VX2000 option, the D2000Pro is able to perform tests over WAN/datacom
lines with a bit rate up to 2.048 Mbit/s.
Thanks to the possibility to emulate both DTE (Data Terminal Equipment) and DCE
(Data Communications Equipment), the D2000Pro allows to carry out quality tests,
bit error rate (BER), in end-to-end mode over datacom line, or checks toward the
User’s DTE (CSU, router, or other WAN equipment).
The criteria monitoring and the possibility to manage local loops (LL), allow to
extend controls over datacom line.
The interfaces supported are: V.35, V.36 and V.11 (X.21),
Fig. 1-1 (single end)
The following paragraphs refer to various tests available using the D2000Pro
interface, further information about the D2000Pro are available in the User’s Manual
of the device.
1.1 Opening the Manual Test Screen
To select the manual test:
1
Open the TEST MENU.
The last used setup appears on the screen.
2
Select the ACCESS field.
3
Select the type of access, V/X INTERFACE.
Quick Guide VX2000
8
GB
4
Select the ACT AS field.
5
Select the instrument mode, e.g. DTE.
The lower section of the screen shows the selected
network configuration. The yellow LED that corresponds to
the selected mode goes on.. It’s possible to choose
between DTE and DCE
6
Select MANUAL TESTS.
7
Select the test UNFRAMED BER.
In order to connect to the line, use the appropriate cable
according to the selected mode. In case of DCE mode, an
appropriate cable, to order separately, is needed.
1.2 Common Setup
This page is used to setup the common parameters for the various tests.
1
To select the COMMON SETUP page
Quick Guide VX2000
9
GB
1
The COMMON SETUP page can be selected from any
test
2
Choose the desired field
The following parameters can be defined for the V/X INTERFACE access:
Interface type: Choose the interface to use among:
V.35, V.36, V.11 (X.21)
Line rate: Select the line rate, in Kbit/s, used by the device to transmit the data.
Only if Clock TX = Inside and mode = DCE
Ignore criteria: Enable or disable the criteria control
Quick Guide VX2000
10
GB
NO, the device guarantees and controls the C108, C107, C105, C106 and C109i
criteria
YES, the management and the check of these criteria, between DTE and DCE, is
disabled
Clock RX: Define the type of clock used to receive data; with CLOCK RX:
LOOPED, the device samples data received with the clock coming from DTE
(C113). Only DCE.
In DCE mode, the clock TX is fixed at “INSIDE”, whereas in DTE
mode, the device uses the clock coming from the DCE over
C114 criterion.
Loop3 (C141): Set “YES” to ask the DCE to perform a local loop (LL) of the data.
Only DTE.
The LL (local loop) request is supported by V.35 and V.36
interfaces only.
1.3 UNFRAMED BER Test
In order to run a line quality test, select from the manual test menu, the
UNFRAMED BER and set the following parameters:
Duration: Choose the duration of the test. Select from the defined list or define your
own duration
Pass/Fail test: Choose the BER value. This value is used to determine the pass or
fail test condition. Selecting G.821, the result is compared with the quality
performance required by G.821. Only for line rate 64Kbit/s.
Error injection: Choose the BER value used for manual or automatic bit error
injection
Bit sequence: Set the pseudo-random pattern to be used. Select from the list
Quick Guide VX2000
11
GB
HRX(%): Enter the variation percentage for the DM and SES thresholds. Only for 1
channel bandwidth
DM Threshold: Choose the number of errors per minute to consider it as degraded.
Use the G.821 (4) default value when no other value is preferred. Only for line rate
64Kbit/s
SES Threshold: Choose the number of errors per second to be considered as
severely errored. Use the G.821 (64) default value when no other value is preferred.
Only for line rate 64Kbit/s
Auto print: Choose the autoprint condition for the test results between:
Time interval: every 15 or 30 minutes
DM: when the DM threshold value is exceeded
1.3.1 Running an Unframed BER Test
VX2000 adapter is fed directly by the D2000Pro, this cause a
decrease of the battery duration.
The test can be carried out both end-to-end and single end mode. In the first case is
necessary to put another D2000Pro/VX2000 at the remote end of the line (fig. 1-2).
In single-end mode, is necessary to carry out a loop over the line. The loop can be
request to DCE with C141 criterion, through a specific command given to the DCE
or carrying out a physical loop between TX side and RX side (see figure 1-1).
Fig. 1-2 (end-to-end)
When you have defined the setup for the Unframed BER test, continue as follows:
1
Select ‘Use this setup for testing’ in the first SETUP page.
2
Connect the instrument as displayed on the screen and
press the RIGHT CURSOR key.
Quick Guide VX2000
12
GB
3
Start the BER test.
The LED RUN goes on and the test results appear on the screen.
4
Scroll through the result pages.
The pages show the following results for each call:
The status line indicates the status of the test.
Bit Error Rate (BER)
Received bits
Errored bits transmitted
Errored bits received
Synchronization and time without synchronization expressed in h, m, s (S-loss).
Result of the PASS/FAIL test
Quick Guide VX2000
13
GB
G.821 data: SES (severely errored seconds), DM (degraded minutes), ES
(errored seconds), US (unavailable seconds) in absolute value and percentage,
result of the PASS/FAIL test according the G.821 quality targets.
2 SMART STATUS
To have a complete description of the Smart Status feature, see the specific
chapter in the D2000Pro User’s Manual.
2.1 V/X Interface status
The 2
nd
page, relative to V/X INTERFACE access, shows the activity of the used
interface.
1
Goes to page 2.
The Clock Rx value, is displayed on the Status pages only if the
clock value has been set as ‘Looped’, in the common setup.
Selecting the relative interface field and pushing ENTER, it is possible to insert a
loop on the data, the device will send, in transmission, the data received from the
remote. Perform the same operation to remove the loop.
The 3
rd
page shows the state of criteria toward DCE and DTE
2
Goes to page 3.
Quick Guide VX2000
14
GB
The criteria displayed are:
C103, C104, data transmitted respectively from DTE and from DCE
C113, C115, clock transmitted respectively from DTE and from DCE
C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD)
C141, loop request from DTE to DCE
3 TECHNICAL SPECIFICATIONS
INTERFACES
V.11
Conforms at
User’s connection
CCITT (ITU-T) Rec.V.11
15 poles male, ISO 4903
V.35
Conforms at
User’s connection
CCITT (ITU-T) Rec.V35
34 poles male, ISO 2593
V.36
Conforms at
User’s connection
CCITT (ITU-T) Rec.V.36
37 poles male, ISO 4902
Transmission Clock
Structure
N*64Kbps
Quick Guide VX2000
15
GB
Maximum rate 2.048Kbps
Reception Clock
Structure
Maximum rate
N*64Kbps
2.048Kbps
Criteria
Management and reading
C108, C107, C105, C106, C109, C141
ENVIRONMENTAL CHARACTERISTICS
Dimension
Weight, with battery
Dimensions (mm)
200 gr.
84 (w) x 150 (l) x 32 (d)
Power
Hint
Accessory is feed through D2000
PRO
power out port
Temperature
Storage/Transport
Operating, nominal
Operating, limits
-40
o
C to +70
o
C
-5
o
C to +45
o
C
-10
o
C to +55
o
C
Humidity, non-condensing
93% RH @ 40
o
C
70% RH @ 55
o
C
Altitude
Storage/transport
Operating
12,000 meters
4,500 meters
User's Safety Aspects
EN 61010-1, EN 60950, EN 41003
EMC Aspects
EN 55022, EN 55024, EN 61000-3-2 / -
3-3
CE Marking
Class B (residential devices)
Quick Guide VX2000
16
GB
4 FUNCTIONAL SPECIFICATIONS
OPERATING MODES AVAILABLE
Simulation
Ignore criteria
Mode selection
DTE, DCE
User defined
Runtime
USER’S BIT RATE
Transmission Clock
Structure
DTE
DCE
Internal clock rates
External maximum rate
Mode selection
N*64Kbps
External (C114 -> C113)
Internal (C115)
48, 64, 128, 192, 256, 320, 384, 512,
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
2.048Kbps
Runtime
Reception Clock
Structure
DTE
DCE
Internal clock rates
External maximum rate
Mode selection
N*64Kbps
External (C115)
Internal (C114), Looped (C113)
48, 64, 128, 192, 256, 320, 384, 512,
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
2.048Kbps
Runtime
Quick Guide VX2000
17
GB
4.1 Pin Out
DTE Mode
DCE Mode
1 - Nc
2 - C113A
3 - C115B
4 - C105
,
Control A
(
V.11
)
5 - C106
,
Indication A
(
V.11
)
6 - C103A
(
TxA
1
)
7 - Ground
8 - C114A
9 - C104A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C107
11 - C141
13 - Reserved
In
Out
-
C113B -14
Out
In
Out
Out
In
In
In
In
-
Out
C115A -15
Control B
(
V.11
)
-16
Indication B
V.11
-17
C103B
(
TxB
1
)
-18
C114B -19
C104B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C108 -24
Ground -25
Out
Out
Out
In
In
In
In
In
-
-
1 - Nc
2 - C114A
3 - C115B
4 - C106
,
Indication A
(
V.11
)
5 - C105
,
Control A
(
V.11
)
6 - C104A
(
TxA
1
)
7 - Ground
8 - C115A
9 - C103A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C108
11 - Reserved
13 - Reserved
Out
Out
-
C114B -14
Out
Out
Out
Out
In
Out
In
Out
-
Out
C115A -15
Indication B
V.11
-16
Control B
(
V.11
)
-17
C104B
(
TxB
1
)
-18
C115B -19
C103B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C107 -24
Ground -25
Out
Out
-
In
Out
In
Out
In
-
-
Quick Guide VX2000
18
GB
X.21bis/V.35 - 34 poles socket (ISO2593) – DTE mode
PIN CRITERION DIRECTION
AA C114B In
Y C114A In
S C103B (TxB1) Out
P C103A (TxA1) Out
X C115B In
V C115A In
T C104B (RxB1) In
R C104A (RxA1) In
W C113B Out
U C113A Out
F C109 (DCD) In
H C108 (DTR) Out
E C107 (DSR) In
D C106 (CTS) In
C C105 (RTS) Out
L C141 (LL) Out
B Ground -
X.21bis/V.36 - 37 poles socket (ISO4902) - DTE mode
PIN CRITERION DIRECTION
23 C114B In
5 C114A In
22 C103B (TxB1) Out
4 C103A (TxA1) Out
26 C115B In
Quick Guide VX2000
19
GB
8 C115A In
24 C104B (RxB1) In
6 C104A (RxA1) In
35 C113B Out
17 C113A Out
13 C109 (DCD) In
12 C108 (DTR) Out
11 C107 (DSR) In
9 C106 (CTS) In
7 C105 (RTS) Out
10 C141 (LL) Out
20, 25, 30,
37
Ground -
X.21/V.11 - 15 pole socket (ISO4903) - DTE mode
PIN CRITERION DIRECTION
9 C103B (TxB
1
) Out
2 C103A (TxA
1
) Out
13 C115B In
6 C115A In
11 C104B (RxB
1
) In
4 C104A (RxA
1
) In
14 Byte timing A (n.a.) In
7 Byte timing B (n.a.) In
3 Control A Out
10 Control B Out
5 Indication A In
12 Indication B In
Quick Guide VX2000
20
GB
8 Ground -
1
Signals referred to D2000Pro
4.2 Optional Codes
CODE DESCRIPTION
6100999171 Cable kit, DTE simulation
6100999172 Cable kit, DCE simulation
Quick Guide VX2000
21
I
VX2000
MULTIPROTOCOL
INTERFACE
OPZIONE D2000PRO
MANUALE D’USO
Le informazioni contenute in questo documento
sono di proprietà della Aethra
®
Telecomunicazioni
S.p.a., sono soggette a modifiche senza preavviso
e non rappresentano impegno da parte della
Aethra
®
Telecomunicazioni S.p.a.
© Copyright Aethra
®
Telecomunicazioni Spa 2002
Tutti i diritti riservati
Rev. 3/2.62 – Dicembre 2002 Code 074042002ML
Questo manuale è composto da 18 pagine
Quick Guide VX2000
22
I
Indice
1 INTRODUZIONE .................................................................................... 24
1.1 APERTURA SCHERMATA DELLE PROVE MANUALI .................... 24
1.2 SETUP GENERALE .......................................................................... 25
1.3 PROVA UNFRAMED BER................................................................. 27
1.3.1 ESECUZIONE DI UNA PROVA UNFRAMED BER..................... 28
2 SMART STATUS.................................................................................... 30
2.1 STATO INTERFACCIA V/X ............................................................... 30
3 SPECIFICHE TECNICHE....................................................................... 32
4 SPECIFICHE FUNZIONALI.................................................................... 33
4.1 PIN OUT ............................................................................................ 34
4.2 CODICI OPZIONALI .......................................................................... 37
Quick Guide VX2000
23
I
NORME DI SICUREZZA
Il passaggio da ambienti freddi ad ambienti caldi può determinare la
formazione di condensa all'interno dell'apparato. In questi casi, per evitare
malfunzionamenti, si consiglia di attendere almeno 2 ore prima di
connettere l'apparato alla rete di alimentazione.
Evitare di accedere alle parti interne dell'apparato (e/o dell'alimentatore).
In caso di penetrazione di oggetti o liquidi all'interno dell'apparato,
scollegare immediatamente il cavo di alimentazione. Prima di riutilizzare
l'apparato, farlo controllare da personale specializzato.
Per l'assistenza rivolgersi a personale qualificato.
In caso di intervento accertarsi sempre che l'apparato sia completamente ed
efficacemente isolato dalla alimentazione.
In caso di incendio, evitare in modo assoluto di usare acqua come mezzo
estinguente.
PRECAUZIONI
Molti dei componenti utilizzati in questo apparato sono sensibili alle scariche
elettrostatiche.
Nel caso di eventuale manipolazione dei cavi di collegamento, disinserire
l'alimentazione elettrica ed evitare contatti diretti con i terminali dei
connettori.
Nella necessità di dover maneggiare qualsiasi componente elettronico,
eliminare l'eventuale elettricità statica di cui si potrebbe essere portatori,
toccando un piano di massa per scaricarla a terra. Se possibile, indossare
un bracciale a massa.
L'inosservanza di queste precauzioni potrebbe causare danni permanenti
all'apparato.
Al fine di garantire una protezione continua per la sicurezza dell'operatore,
utilizzare esclusivamente l'adattatore di rete fornito in dotazione con
l'apparato.
Quick Guide VX2000
24
I
1 INTRODUZIONE
Tramite l'opzione VX2000, il D2000Pro è in grado di effettuare prove su linee
WAN/datacom con bit rate fino a 2.048 Mbit/s.
Grazie alla possibilità di emulare sia l'apparato DTE (Data Terminal Equipment) che
il DCE (Data Communications Equipment), il D2000Pro permette di effettuare prove
di qualità, bit error rate (BER), in modalità end-to-end sulla linea dati o verifiche
verso il DTE utente (CSU, router, o altro apparato WAN).
Il monitoraggio dei criteri e la possibilità di gestire i loop locali (LL) permettono di
estendere i controlli sulla linea dati.
Le interfacce supportate sono la V.35, V.36 e V.11 (X.21),
Figura 1-1 (single end)
I paragrafi che seguono fanno riferimento alle varie prove disponibili utilizzando
l'interfaccia del D2000Pro, ulteriori informazioni sul D2000Pro sono disponibili sul
manuale d'uso dello strumento.
1.1 Apertura schermata delle prove manuali
Per scegliere una prova manuale:
1
Per aprire il menu principale.
Il display visualizza l’ultima configurazione usata.
2
Per selezionare il campo ACCESSO.
3
Selezionare il tipo di accesso, INTERFACCIA V/X.
Quick Guide VX2000
25
I
4
Per selezionare il campo MODALITÀ.
5
Per selezionare il modo dello strumento, es. DTE.
La sezione inferiore del display visualizza la
configurazione di rete selezionata, il LED giallo
corrispondente al modo scelto si accende. E’ possibile
scegliere tra DTE e DCE.
6
Per selezionare il menu di scelta delle PROVE MANUALI.
7
Per selezionare la prova UNFRAMED BER.
Per la connessione alla linea, utilizzare il cavo opportuno alla
modalità selezionata. Nel caso di modalità DCE, occorre
utilizzare un apposito cavo ordinabile separatamente.
1.2 Setup Generale
Tramite questa pagina è possibile impostare i parametri dello strumento che sono in
comune tra le varie prove.
1
Per selezionare la pagina di SETUP GENERALE.
Quick Guide VX2000
26
I
1
È possibile selezionare la pagina di SETUP GENERALE
anche all’interno di una prova.
2
Per selezionare il campo di interesse.
Per l'accesso V/X, possono essere definiti i seguenti parametri:
Tipo interfaccia: Selezionare il tipo di interfaccia utilizzata tra:
V.35, V.36, V.11 (X.21)
Velocità di linea: Selezionare la velocità di linea, in Kbit/s, utilizzata dallo
strumento per trasmettere i dati. Solo se Clock TX = Interno e modo = DCE
Ignora criteri: Attivare o disattivare il controllo dei criteri
Quick Guide VX2000
27
I
NO, lo strumento gestisce e controlla i criteri C108, C107, C105, C106 e C109
SI, viene disabilitata la gestione e la verifica dei suddetti criteri tra DTE e DCE
Clock RX: Definire il tipo di clock utilizzato per ricevere i dati; con CLOCK RX:
RIGENERATO, lo strumento campiona i dati ricevuti con il clock proveniente dal
DTE (C113). Solo DCE.
In modalità DCE, la sorgente per il clock di trasmissione dei dati
è fisso a INTERNO, mentre in modalità DTE lo strumento utilizza
il clock proveniente dal DCE sul criterio C114.
Loop3 (C141): Impostare “SI” per richiedere al DCE di eseguire un loop locale (LL)
dei dati. Solo DTE.
La richiesta di loop LL è supportata solo dalle interfacce V.35 e
V.36.
1.3 Prova UNFRAMED BER
Per eseguire una prova di qualità della linea, selezionare dal menu delle prove
manuali la prova UNFRAMED BER e impostare i seguenti parametri:
Durata: Inserire il tempo di durata della prova dalla lista predefinita o definire la
propria durata.
Prova Pass/Fail: Selezionare il valore BER da utilizzare per determinare il
superamento o il fallimento della prova. Selezionando G.821, il risultato viene
confrontato con le performance di qualità richieste dalla G.821. Solo per velocità di
linea 64Kbit/s.
Iniezione errore: Selezionare il valore BER utilizzato per l’iniezione di errori, in
modo manuale o automatico.
Sequenza bit: Impostare la sequenza pseudocasuale di bit da utilizzare dalla lista,
o definire il proprio modello.
HRX(%):Inserisci la percentuale di variazione delle soglie DM e SES. Solo per
velocità di linea 64Kbit/s.
Quick Guide VX2000
28
I
Soglia DM: Selezionare il numero di errori al minuto per considerarlo degradato.
Usare il valore di default G.821 (4) quando non è richiesto un altro valore. Solo per
velocità di linea 64Kbit/s.
Soglia SES: Selezionare il numero di errori al secondo per considerarlo
severamente errato. Usare il valore di default G.821 (64) quando non è richiesto un
altro valore. Solo per velocità di linea 64Kbit/s.
Stampa automatica: Selezionare la condizione di stampa automatica per i risultati
della prova tra:
Intervallo di tempo: ogni 15 o 30 minuti
DM: quando viene superata la soglia DM
1.3.1 Esecuzione di una prova Unframed BER
L’adattatore VX2000 viene alimentato direttamente dal
D2000Pro, questo provoca una diminuzione della durata della
batteria.
La prova può essere effettuata sia in modo end-to-end che in modo single end. Nel
primo caso occorre posizionare un altro D2000Pro/VX2000 all'estremo remoto della
linea (figura 1-2). In modo single-end, è necessario effettuare un loop sulla linea. Il
loop può essere richiesto al DCE con il criterio C141, via specifico comando da
dare al DCE o eseguendo un loop fisico tra lato TX e lato RX (vedi figura 1-1).
Figura 1-2 (end-to-end)
Una volta impostata la configurazione della prova UNFRAMED BER, continuare
come indicato di seguito:
1
Per selezionare ‘Usa questo setup per la prova’ nella
prima pagina di CONFIGURAZIONE.
2
Collegare lo strumento come visualizzato sul display e
premere il tasto CURSORE DESTRO.
Quick Guide VX2000
29
I
3
Per iniziare la prova BER.
Il LED RUN si accende e i risultati della prova compaiono sul display.
4
Per muoversi tra le pagine dei risultati.
Le pagine mostrano i seguenti risultati per ciascuna chiamata:
La riga di stato indica lo stato della prova.
Bit Error Rate (BER)
Bit ricevuti
Bit errati inviati
Bit errati ricevuti
Sincronizzazione e tempo senza sincronizzazione espresso in h, m, s, (S-loss)
Risultato del test PASS/FAIL
premere il tasto CURSORE DESTRO.
Quick Guide VX2000
30
I
Dati G.821: SES (secondi gravemente errati), DM (minuti degradati), ES (secondi
errati), US (secondi non disponibili), in valore assoluto e percentuale, risultato del
test PASS/FAIL secondo gli obbiettivi di qualità G.821.
2 SMART STATUS
Per la descrizione completa della funzione di Smart Status, vedere lo specifico
capitolo sul manuale d'uso dello strumento.
2.1 Stato interfaccia V/X
La seconda pagina relativa all’accesso INTERFACCIA V/X, mostra il tipo di attività
dell’interfaccia utilizzata.
1
Per passare alla seconda pagina.
Il valore del Clock Rx, viene visualizzato nelle pagine di Status
solo se il valore di clock è stato impostato come ‘Rigenerato’,
nel setup generale.
Selezionando il campo relativo all'interfaccia e premendo il tasto ENTER, è
possibile inserire un loop sui dati, lo strumento invierà in trasmissione i dati ricevuti
dal remoto. Eseguire la stessa operazione per rimuovere il loop.
La terza pagina mostra lo stato degli criteri verso DCE e verso DTE
2
Per passare alla terza pagina.
Quick Guide VX2000
31
I
I criteri mostrati sono:
C103, C104,dati trasmessi rispettivamente dal DTE e dal DCE
C113, C115, clock trasmesso rispettivamente dal DTE e dal DCE
C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD)
C141, richiesta di loop dal DTE al DCE
Quick Guide VX2000
32
I
3 SPECIFICHE TECNICHE
INTERFACCE
V.11
Conforme a
Tipo di connettore
CCITT (ITU-T) Rec.V.11
15 poli maschio, ISO 4903
V.35
Conforme a
Tipo di connettore
CCITT (ITU-T) Rec.V35
34 poli maschio, ISO 2593
V.36
Conforme a
Tipo di connettore
CCITT (ITU-T) Rec.V.36
37 poli maschio, ISO 4902
Clock di trasmissione
Struttura
Velocità massima
N*64Kbps
2.048Kbps
Clock di ricezione
Struttura
Velocità massima
N*64Kbps
2.048Kbps
Criteri
Gestione e lettura
C108, C107, C105, C106, C109, C141
CARATTERISTICHE AMBIENTALI
Dimensioni
Peso con batteria
Dimensioni (mm)
200 gr.
84 (w) x 150 (l) x 32 (d)
Power
Hint
L’accessorio è alimentato dalla porta
t d l D2000 PRO
Quick Guide VX2000
33
I
power out del D2000 PRO
Temperatura
Immagazzinamento/Trasporto
Temperatura di funzionamento
Limiti di operabilità
-40
o
C a +70
o
C
-5
o
C a +45
o
C
-10
o
C a +55
o
C
Umidità relativa (senza
condensazione)
93% RH @ 40
o
C
70% RH @ 55
o
C
Altitudine
Immagazzinamento/Trasporto
Operabilità
12,000 metri
4,500 metri
Norme di sicurezza per l’utente
EN 61010-1, EN 60950, EN 41003
Norme EMC
EN 55022, EN 55024, EN 61000-3-2 / -
3-3
CE Marking
Classe B
4 SPECIFICHE FUNZIONALI
MODALITÀ OPERATIVE DISPONIBILI
Simulazione
Ignora criteri
Modalità di selezione
DTE, DCE
Definito da utente
Runtime
VELOCITÀ D’UTENTE
Clock di trasmissione
Struttura
DTE
DCE
Velocità interna del clock
N*64Kbps
Esterno (C114 -> C113)
Interno (C115)
48, 64, 128, 192, 256, 320, 384, 512,
640 768 960 1 024 1 280 1 536
Quick Guide VX2000
34
I
Massima velocità esterna
Modalità di selezione
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
2.048Kbps
Runtime
Clock di ricezione
Struttura
DTE
DCE
Velocità interna del clock
Massima velocità esterna
Modalità di selezione
N*64Kbps
Esterno (C115)
Interno (C114), Looped (C113)
48, 64, 128, 192, 256, 320, 384, 512,
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
2.048Kbps
Runtime
4.1 Pin Out
DTE Mode
1 - Nc
2 - C113A
3 - C115B
4 - C105
,
Control A
(
V.11
)
5 - C106
,
Indication A
(
V.11
)
6 - C103A
(
TxA
1
)
7 - Ground
8 - C114A
9 - C104A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C107
11 - C141
13 - Reserved
In
Out
-
C113B -14
Out
In
Out
Out
In
In
In
In
-
Out
C115A -15
Control B
(
V.11
)
-16
Indication B
V.11
-17
C103B
(
TxB
1
)
-18
C114B -19
C104B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C108 -24
Ground -25
Out
Out
Out
In
In
In
In
In
-
-
Quick Guide VX2000
35
I
DCE Mode
X.21bis/V.35 - connettore a 34 poli (ISO2593) - modo DTE
PIN CRITERIO DIREZIONE
AA C114B In
Y C114A In
S C103B (TxB1) Out
P C103A (TxA1) Out
X C115B In
V C115A In
T C104B (RxB1) In
R C104A (RxA1) In
W C113B Out
U C113A Out
F C109 (DCD) In
H C108 (DTR) Out
E C107 (DSR) In
D C106 (CTS) In
C C105 (RTS) Out
1 - Nc
2 - C114A
3 - C115B
4 - C106
,
Indication A
(
V.11
)
5 - C105
,
Control A
(
V.11
)
6 - C104A
(
TxA
1
)
7 - Ground
8 - C115A
9 - C103A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C108
11 - Reserved
13 - Reserved
Out
Out
-
C114B -14
Out
Out
Out
Out
In
Out
In
Out
-
Out
C115A -15
Indication B
V.11
-16
Control B
(
V.11
)
-17
C104B
(
TxB
1
)
-18
C115B -19
C103B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C107 -24
Ground -25
Out
Out
-
In
Out
In
Out
In
-
-
Quick Guide VX2000
36
I
L C141 (LL) Out
B Ground -
X.21bis/V.36 - connettore a 37 poli (ISO4902) - modo DTE
PIN CRITERIO DIREZIONE
23 C114B In
5 C114A In
22 C103B (TxB1) Out
4 C103A (TxA1) Out
26 C115B In
8 C115A In
24 C104B (RxB1) In
6 C104A (RxA1) In
35 C113B Out
17 C113A Out
13 C109 (DCD) In
12 C108 (DTR) Out
11 C107 (DSR) In
9 C106 (CTS) In
7 C105 (RTS) Out
10 C141 (LL) Out
20, 25, 30,
37
Ground -
X.21/V.11 - connettore a 15 poli (ISO4903) - modo DTE
PIN CRITERIO DIREZIONE
9 C103B (TxB
1
) Out
Quick Guide VX2000
37
I
2 C103A (TxA
1
) Out
13 C115B In
6 C115A In
11 C104B (RxB
1
) In
4 C104A (RxA
1
) In
14 Byte timing A (n.a.) In
7 Byte timing B (n.a.) In
3 Control A Out
10 Control B Out
5 Indication A In
12 Indication B In
8 Ground -
1
Segnali riferiti al D2000Pro.
4.2 Codici opzionali
CODICE DESCRIZIONE
6100999171 Kit cavi, simulazione DTE
6100999172 Kit cavi, simulazione DCE
Quick Guide VX2000
38
E
VX2000
MULTIPROTOCOL
INTERFACE
OPCIÓN D2000PRO
MANUAL DE USUARIO
Las informaciones contenidas en este documento
son propiedad de Aethra
®
Telecomunicazioni
S.p.a., están sujetas a modificaciones sin aviso
previo y no representan un compromiso por parte
de Aethra
®
Telecomunicazioni S.p.a.
© Copyright Aethra
®
Telecomunicazioni Spa 2002.
Todos los derechos reservados
Rev. 3/2.62 Diciembre 2002 Código 074042002ML
Este manual está compuesto por 18 páginas
Quick Guide VX2000
39
E
Índice
1 INTRODUCCIÓN.................................................................................... 41
1.1 CÓMO SELECCIONAR UNA PRUEBA MANUAL............................ 41
1.2 SETUP GENERAL............................................................................. 42
1.3 PRUEBA UNFRAMED BER............................................................... 44
1.3.1 REALIZACIÓN DE UNA PRUEBA UNFRAMED BER................. 45
2 SMART STATUS.................................................................................... 47
2.1 ESTADO INTERFAZ V/X................................................................... 47
3 ESPECIFICACIONES TÉCNICAS ......................................................... 49
4 ESPECIFICACIONES FUNCIONALES .................................................. 50
4.1 PIN OUT ............................................................................................ 51
4.2 CODIGOS OPCIÓNALES.................................................................. 54
Quick Guide VX2000
40
E
NORMAS DE SEGURIDAD
El pasaje de ambientes fríos a calientes puede determinar la formación de
condensación dentro del aparato. En estos casos, para evitar
funcionamientos inadecuados, se aconseja esperar por lo menos 2 horas
antes de conectar el aparato a la red de alimentación.
No acceda a las piezas internas del aparato (y/o del alimentador).
En caso de penetración de objetos o líquidos dentro del aparato,
desconecte inmediatamente el cable de alimentación. Antes de utilizar
nuevamente el aparato, hágalo controlar por personal especializado.
Para la asistencia utilice personal cualificado.
En caso de intervención, asegúrese siempre de que el aparato se
encuentre completa y eficazmente aislado de la alimentación.
En caso de incendio, evite absolutamente el uso de agua como medio de
extinción.
PRECAUCIONES
Muchos de los componentes utilizados en este aparato son sensibles a las
descargas electrostáticas.
En caso de manipulación de los cables de conexión, desconecte la
alimentación eléctrica y evite cualquier contacto directo con los terminales
de los conectores.
En caso de que se deba manipular cualquier componente electrónico,
elimine la eventual electricidad estática tocando una superficie de masa
para descargarla. Si es posible, póngase un brazal de masa.
El incumplimiento de estas precauciones podría causar daños permanentes
al aparato.
Para asegurar una protección continua para la seguridad del operador,
utilice exclusivamente el adaptador de red suministrado con el aparato.
Quick Guide VX2000
41
E
1 INTRODUCCIÓN
Mediante la opción VX2000 el D2000Pro puede realizar pruebas sobre líneas
WAN/datacom con velocidad de transmisión de hasta 2.048 Mbit/s.
Gracias a la posibilidad de emular tanto el aparato DTE (Data Terminal Equipment)
como el DCE (Data Communications Equipment), el D2000Pro permite realizar
pruebas de calidad, bit error rate (BER) de modo “end-to-end” sobre la línea de
datos o verificaciones hacia el DTE de usuario (CSU, enrutador u otro aparato
WAN).
El control de los criterios y la posibilidad de gestionar los bucles locales (LL)
permiten extender los controles sobre la línea de datos.
Las interfaces soportadas son V.35, V.36 y V.11 (X.21),
Figura 1-1 (single end)
Los capítulos que siguen se refieren a las varias pruebas disponibles utilizando la
interfaz del D2000Pro. Para informaciones sobre el D2000Pro véase el manual de
usuario del instrumento.
1.1 Cómo seleccionar una prueba manual
Para seleccionar una prueba manual:
1
Para abrir el menú principal.
La pantalla visualiza la última configuración utilizada.
2
Para seleccionar el campo ACCESO.
3
Seleccione el tipo de acceso, INTERFAZ V/X.
Quick Guide VX2000
42
E
4
Para seleccionar el campo ACTÚE COMO.
5
Para seleccionar el modo del instrumento, por ejemplo
DTE. La parte inferior de la pantalla visualiza la
configuración de red seleccionada. El LED de color
amarillo correspondiente al modo seleccionado se
enciende. Se puede elegir entre DTE y DCE.
6
Para seleccionar el menú de selección de las PRUEBAS
MANUALES.
7
Para seleccionar la prueba UNFRAMED BER.
Para la conexión a la línea utilice el cable adecuado para el
modo seleccionado. En modo DCE se necesita utilizar un cable
específico a pedir separadamente.
1.2 Setup General
En esta página se pueden definir los parámetros del instrumento comunes para las
varias pruebas.
1
Para seleccionar la página de SETUP GENERAL.
Quick Guide VX2000
43
E
1
La página de SETUP GENERAL puede seleccionarse
también dentro de cualquier prueba.
2
Para seleccionar el campo de interés.
Para el acceso V/X pueden definirse los parámetros siguientes:
Tipo interfaz: Seleccione el tipo de interfaz utilizado entre:
V.35, V.36, V.11 (X.21)
Velocidad de línea: Seleccione la velocidad de línea en Kbit/s utilizada por el
instrumento para transmitir los datos. Sólo si Clock TX = Interno y modo = DCE.
Ignora criterios: Activar o desactivar el control de los criterios
Quick Guide VX2000
44
E
NO, el instrumento gestiona y controla los criterios C108, C107, C105, C106 y
C109
SI, para desactivar la gestión y verificación de los criterios entre DTE y DCE
Reloj RX: Definir el tipo de reloj utilizado para recibir los datos. Con CLOCK RX:
REGENERADO el instrumento compara los datos recibidos con el reloj procedente
del DTE (C113). Sólo DCE.
En modo DCE la fuente para el reloj de transmisión de los datos
es fija a INTERNO. En modo DTE el instrumento utiliza el reloj
procedente del DCE en el criterio C114.
Bucle3 (C141): Seleccione “SI” para que el DCE realice un bucle local (LL) de los
datos. Sólo DTE.
La petición de bucle LL es soportada solamente por las
interfaces V.35 y V.36.
1.3 Prueba UNFRAMED BER
Para realizar una prueba de calidad de la línea seleccione la prueba UNFRAMED
BER en el menú de las pruebas manuales y defina los parámetros siguientes:
Duración: Seleccione la duración de la prueba en la lista predefinida o bien defina
la propia duración.
Prueba Pasa/Falla: Seleccione el valor BER utilizado para determinar la condición
de prueba pasada o fallada. Seleccionando G.821 el resultado se compara con las
prestaciones de calidad establecidas por G.821. Sólo para velocidad de línea
64Kbit/s.
Inyección error: Seleccione el valor BER utilizado para la inyección de errores
manual o automática.
Secuencia de bit: Seleccione la secuencia pseudoaleatoria de bitios utilizada de la
lista o bien defina el propio modelo.
Quick Guide VX2000
45
E
HRX(%): Ingrese el porcentaje de variación de los umbrales DM y SES. Sólo para
velocidades de línea 64Kbit/s.
Umbral DM: Seleccione el número de errores por minuto para considerarlo
degradado. Utilice el valor por defecto G.821 (4) cuando no se requiere otro valor.
Sólo para velocidad de línea 64Kbit/s.
Umbral SES: Seleccione el número de errores por segundo para considerarlo
severamente errado. Utilice el valor por defecto G.821 (64) cuando no se requiere
otro valor. Sólo para velocidad de línea 64Kbit/s.
Impresión automática: Seleccione la condición de impresión automática para
imprimir los resultados de la prueba entre:
Intervalo de tiempo: cada 15 o 30 minutos
DM: cuando se supera el valor del umbral DM
1.3.1 Realización de una prueba Unframed BER
El adaptador VX2000 recibe alimentación directamente del
D2000Pro. Esto reduce la duración de la batería.
La prueba puede realizarse tanto de modo “end-to-end” como “single end”. En el
primer caso se necesita colocar otro D2000Pro/VX2000 en la extremidad remota de
la línea (figura 1-2). De modo “single-end” se necesita realizar un bucle sobre la
línea. El bucle puede solicitarse al DCE con el criterio C141 mediante comando
específico al DCE o realizando un bucle físico entre el lado TX y el lado RX (véase
figura 1-1).
Figura 1-2 (end-to-end)
Una vez definida la configuración de la prueba UNFRAMED BER continúe como
indicado a continuación:
Quick Guide VX2000
46
E
1
Para seleccionar ‘Utilice este setup para el test’ en la
primera página de CONFIGURACIÓN.
2
Conecte el instrumento como visualizado en la pantalla y
pulse la tecla CURSOR DERECHA.
3
Para empezar la prueba BER.
El LED RUN se enciende y los resultados de la prueba aparecen en la pantalla.
4
Para moverse por las páginas de los resultados.
Las páginas muestran los resultados siguientes para cada llamada:
La línea de estado indica el estado de la prueba.
Bit Error Rate (BER)
Bit recibidos
Bit errados transmitidos
Bit errados recibidos
Pérdida de sincronismo en la secuencia recibida
Quick Guide VX2000
47
E
Resultado de la prueba PASA/FALLA
Datos G.821: SES (segundos gravemente errados), DM (minutos degradados),
ES (segundos errados), US (segundos no disponibles), en valor absoluto y
porcentaje. Sólo para velocidad de línea 64Kbit/s.
2 SMART STATUS
Para la descripción completa de la función SmartStatus véase el capítulo
correspondiente en el manual de usuario del instrumento.
2.1 Estado interfaz V/X
La segunda página relativa al acceso INTERFAZ V/X muestra el tipo de actividad
de la interfaz utilizada.
1
Para pasar a la segunda página.
Seleccionando el campo relativo a la interfaz y pulsando la tecla ENTER se puede
realizar un bucle sobre los datos. El instrumento envía en transmisión los datos
recibidos por el remoto. Realice la misma operación para remover el bucle.
La tercera página muestra el estado de los criterios hacia DCE y hacia DTE
2
Para pasar a la tercera página.
Quick Guide VX2000
48
E
Los criterios visualizados son:
C103, C104, datos transmitidos respectivamente por el DTE y DCE
C113, C115, reloj transmitido respectivamente por el DTE y DCE
C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD)
C141, solicitud de bucle del DTE al DCE
Quick Guide VX2000
49
E
3 ESPECIFICACIONES TÉCNICAS
INTERFACES
V.11
Conforme a
Tipo de conector
CCITT (ITU-T) Rec.V.11
15 polos macho, ISO 4903
V.35
Conforme a
Tipo de conector
CCITT (ITU-T) Rec.V35
34 polos macho, ISO 2593
V.36
Conforme a
Tipo de conector
CCITT (ITU-T) Rec.V.36
37 polos macho, ISO 4902
Reloj de transmisión
Estructura
Velocidad máxima
N*64Kbps
2.048Kbps
Reloj de recepción
Estructura
Velocidad máxima
N*64Kbps
2.048Kbps
Criterios
Gestión y lectura
C108, C107, C105, C106, C109, C141
CARACTERÍSTICAS AMBIENTALES
Dimensiones
Peso con batería
Dimensiones (mm)
200 gr.
84 (w) x 150 (l) x 32 (d)
Alimentación
Hint
La opción recibe alimentación del
puerto Power Out del D2000 PRO
Quick Guide VX2000
50
E
Temperatura
Almacenamiento/Transporte
Temperatura de funcionamiento
Límites operativos
-40
o
C a +70
o
C
-5
o
C a +45
o
C
-10
o
C a +55
o
C
Humedad relativa (sin
condensación)
93% RH @ 40
o
C
70% RH @ 55
o
C
Altitud
Almacenamiento/Transporte
Operación
12,000 metros
4,500 metros
Normas de seguridad para el
usuario
EN 61010-1, EN 60950, EN 41003
Normas EMC
EN 55022, EN 55024, EN 61000-3-2 / -
3-3
Marca CE
Clase B
4 ESPECIFICACIONES FUNCIONALES
MODOS OPERATIVOS DISPONIBLES
Simulación
Ignora criterios
Modo de selección
DTE, DCE
Definido por el usuario
Runtime
VELOCIDAD DE USUARIO
Reloj de transmisión
Estructura
DTE
DCE
Velocidad interna del reloj
N*64Kbps
Externo (C114 -> C113)
Interno (C115)
48, 64, 128, 192, 256, 320, 384, 512,
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
Quick Guide VX2000
51
E
Máxima velocidad externa
Modo de selección
1.920, 2.048 Kbps
2.048Kbps
Runtime
Reloj de recepción
Estructura
DTE
DCE
Velocidad interna del reloj
Máxima velocidad externa
Modo de selección
N*64Kbps
Externo (C115)
Interno (C114), Looped (C113)
48, 64, 128, 192, 256, 320, 384, 512,
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
2.048Kbps
Runtime
4.1 Pin Out
DTE Mode
1 - Nc
2 - C113A
3 - C115B
4 - C105
,
Control A
(
V.11
)
5 - C106
,
Indication A
(
V.11
)
6 - C103A
(
TxA
1
)
7 - Ground
8 - C114A
9 - C104A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C107
11 - C141
13 - Reserved
In
Out
-
C113B -14
Out
In
Out
Out
In
In
In
In
-
Out
C115A -15
Control B
(
V.11
)
-16
Indication B
V.11
-17
C103B
(
TxB
1
)
-18
C114B -19
C104B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C108 -24
Ground -25
Out
Out
Out
In
In
In
In
In
-
-
Quick Guide VX2000
52
E
DCE Mode
X.21bis/V.35 - conector de 34 polos (ISO2593) - modo DTE
PIN CRITERIO DIRECCIÓN
AA C114B In
Y C114A In
S C103B (TxB1) Out
P C103A (TxA1) Out
X C115B In
V C115A In
T C104B (RxB1) In
R C104A (RxA1) In
W C113B Out
U C113A Out
F C109 (DCD) In
H C108 (DTR) Out
E C107 (DSR) In
D C106 (CTS) In
C C105 (RTS) Out
1 - Nc
2 - C114A
3 - C115B
4 - C106
,
Indication A
(
V.11
)
5 - C105
,
Control A
(
V.11
)
6 - C104A
(
TxA
1
)
7 - Ground
8 - C115A
9 - C103A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C108
11 - Reserved
13 - Reserved
Out
Out
-
C114B -14
Out
Out
Out
Out
In
Out
In
Out
-
Out
C115A -15
Indication B
V.11
-16
Control B
(
V.11
)
-17
C104B
(
TxB
1
)
-18
C115B -19
C103B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C107 -24
Ground -25
Out
Out
-
In
Out
In
Out
In
-
-
Quick Guide VX2000
53
E
L C141 (LL) Out
B Masa -
X.21bis/V.36 - conector de 37 polos (ISO4902) - modo DTE
PIN CRITERIO DIRECCIÓN
23 C114B In
5 C114A In
22 C103B (TxB1) Out
4 C103A (TxA1) Out
26 C115B In
8 C115A In
24 C104B (RxB1) In
6 C104A (RxA1) In
35 C113B Out
17 C113A Out
13 C109 (DCD) In
12 C108 (DTR) Out
11 C107 (DSR) In
9 C106 (CTS) In
7 C105 (RTS) Out
10 C141 (LL) Out
20, 25, 30,
37
Masa -
X.21/V.11 - conector de 15 polos (ISO4903) - modo DTE
PIN CRITERIO DIRECCIÓN
9 C103B (TxB
1
) Out
2 C103A (TxA
1
) Out
Quick Guide VX2000
54
E
13 C115B In
6 C115A In
11 C104B (RxB
1
) In
4 C104A (RxA
1
) In
14 Byte timing A (n.a.) In
7 Byte timing B (n.a.) In
3 Control A Out
10 Control B Out
5 Indicación A In
12 Indicación B In
8 Masa -
1
Señales referidas al D2000Pro.
4.2 Codigos Opciónales
CODIGO DESCRIPCION
6100999171 Cable kit, simulación DTE
6100999172 Cable kit, simulación DCE
Quick Guide VX2000
55
D
VX2000
MULTIPROTOCOL
INTERFACE
OPTION FÜR
D2000PRO
HANDBUCH
Die in diesem Dokument enthaltenen
Informationen sind Eigentum von Aethra
®
Telecomunicazioni S.p.a., können jederzeit ohne
vorherige Mitteilung geändert werden und sind
unverbindlich für Aethra
®
Telecomunicazioni S.p.a.
© Copyright Aethra
®
Telecomunicazioni Spa 2002
Alle Rechte vorbehalten
Rev. 3/2.62 - Dezember 2002 Code 074042002ML
Dieses Handbuch besteht aus 18 Seiten
Quick Guide VX2000
56
D
INHALTSVERZEICHNIS
1 EINLEITUNG.......................................................................................... 58
1.1 PROGRAMMSEITE DER MANUELLEN TESTS ÖFFNEN .............. 58
1.2 ALLGEMEINER SETUP .................................................................... 59
1.3 UNFRAMED BER TEST .................................................................... 61
1.3.1 EINEN UNFRAMED BER TEST AUSFÜHREN .......................... 62
2 SMART STATUS.................................................................................... 64
2.1 ZUSTAND DER V/X - SCHNITTSTELLE........................................... 64
3 TECHNISCHE DATEN ........................................................................... 66
4 UNKTIONSDATEN................................................................................. 67
4.1 PIN OUT ............................................................................................ 68
4.2 OPTIONAL CODES........................................................................... 71
Quick Guide VX2000
57
D
SICHERHEITSVORSCHRIFTEN
Wird das Gerät aus kühlen Räumen in warme Räume gebracht, kann in
seinem Inneren Kondenswasser entstehen. Um Betriebsstörungen zu
vermeiden, sollten Sie in solchen Fällen mindestens 2 Stunden warten,
bevor Sie das Gerät an das Stromnetz anschlissen.
Nicht ins Innere des Geräts (bzw. des Netzgeräts) greifen.
Sollten Gegenstände oder Flüssigkeiten in das Innere des Geräts gelangen,
sofort das Netzkabel herausziehen. Bevor Sie das Gerät wieder benutzen,
lassen Sie es von einem Fachmann prüfen.
Für den Kundendienst wenden Sie sich bitte an qualifiziertes Fachpersonal.
Bevor mit Reparaturarbeiten begonnen wird, überzeugen Sie sich bitte
davon, dass die Spannungsversorgung zum Gerät tatsächlich komplett
unterbrochen worden ist.
Bei Feuer darf auf keinen Fall Wasser zum Löschen verwendet werden.
VORSICHTSMASSNAHMEN
ACHTUNG:
Viele der in diesem Gerät vorhandenen Bauteile sind empfindlich
gegenüber elektrostatischen Entladungen.
Sollten die Anschlusskabel umgesteckt werden, Vorher die
Spannungsversorgung unterbrechen und jeglichen Direktkontakt mit den
Endstücken der Steckverbindungen vermeiden.
Sollte sich die Notwendigkeit ergeben, eines der elektronischen Bauteile
anzufassen, so befreien Sie sich bitte vorher von der Ihnen eventuell
anhaftenden elektrostatischen Ladung durch Berühren einer geerdeten
Oberfläche. Falls möglich, sollten Sie ein geerdetes Armband tragen.
Eine mangelnde Berücksichtigung obiger Vorsichtsmassnahmen kann zur
permanenten Beschädigung des Geräts führen.
Um die kontinuierliche Sicherheit des Bedieners zu gewährleisten, ist
ausschließlich der zusammen mit dem Gerät gelieferte Netzadapter zu
verwenden.
Quick Guide VX2000
58
D
1 EINLEITUNG
Mit der Option VX2000 ist das D2000Pro dazu in der Lage, Tests auf
WAN/datacom Leitungen mit Bit Rates bis zu 2.048 Mbit/s durchzuführen.
Dank der Möglichkeit, sowohl das DTE (Data Terminal Equipment) als auch das
DCE (Data Communications Equipment) zu emulieren, ermöglicht es das
D2000Pro, Qualitätstests bzw. Bit Error Rate (BER) Tests im End-to-End Modus auf
Datenleitungen oder Tests mit dem Teilnehmer - DTE (CSU, Router oder ein
anderes WAN-Gerät) durchzuführen.
Die Überwachung der Kriterien und die Möglichkeit, lokale Loops (LL) zu verwalten,
machen es möglich, auch die Datenlinie zu testen.
Es werden folgende Schnittstellen unterstützt: V.35, V.36 und V.11 (X.21),
Abbildung 1-1 (single end)
In nachfolgenden Absätzen werden die verschiedenen Tests beschrieben, die unter
Verwendung der D2000Pro Schnittstelle durchgeführt werden können. Weitere
Infos über das D2000Pro sind im Anwenderhandbuch des Instruments enthalten.
1.1 Programmseite der manuellen Tests öffnen
So wird ein manueller Test gewählt:
1
Um die Ausgangsseite zu öffnen.
Auf dem Display erscheint die zuletzt verwendete
Konfiguration.
2
Um das ANSCHLUSS Feld zu wählen.
3
Anschlussart wählen, SCHNITTSTELLE V/X.
Quick Guide VX2000
59
D
4
Um das BETRIEBSWEISE (Modus) Feld zu wählen.
5
Um die Betriebsweise (Modus) des Instruments zu
wählen, z.B. DTE.
Im unteren Bereich des Displays erscheint die gewählte
Netzkonfiguration. Die dem gewählten Modus
entsprechende gelbe LED leuchtet auf. Es kann zwischen
DTE und DCE gewählt werden.
6
Um das Auswahlmenü der MANUELLEN TESTS zu
öffnen.
7
Um den UNFRAMED BER Test zu wählen.
Zum Anschluss an die Leitung verwenden Sie bitte ein Kabel,
das dem gewählten Modus entspricht. Für den DCE Modus ist
ein spezielles Kabel zu verwenden, das getrennt bestellt werden
kann.
1.2 Allgemeiner setup
Mit dieser Seite ist es möglich, diejenigen Parameter des Instruments einzugeben,
die für alle Tests gleich bleiben.
1
Zum Öffnen der Seite ALLGEMEINER SETUP.
Quick Guide VX2000
60
D
1
Die Seite ALLGEMEINER SETUP kann auch innerhalb
eines Tests geöffnet werden.
2
Zur Anwahl des gewünschten Feldes.
Für den V/X Anschluss können folgende Parameter festgelegt werden:
Schnittstellenart: Wählen Sie die verwendete Schnittstellenart unter folgenden
Möglichkeiten aus:
V.35, V.36, V.11 (X.21)
Leitungsgeschwindigkeit: Wählen Sie die Leitungsgeschwindigkeit in Kbit/s, die
vom Instrument dazu verwendet wird, die Daten zu übertragen. Nur bei Clock TX =
Intern und Modus = DCE.
Quick Guide VX2000
61
D
Kriterien ignorieren: Kriterienkontrolle aktivieren oder deaktivieren
NEIN, das Instrument verwaltet und prüft folgende Kriterien: C108, C107, C105,
C106 und C109
JA, die Verwaltung und Prüfung obiger Kriterien wird zwischen DTE und DCE
deaktiviert
Clock RX: Festlegung der Clockart, die für den Datenempfang verwendet wird; bei
CLOCK RX: REGENERIERT sampelt das Instrument die empfangenen Daten mit
der vom DTE kommenden Clock (C113). Lediglich DCE.
Im DCE Modus bleibt die Clock-Quelle für die Datenübertragung
fest auf INTERN, während im DTE Modus das Instrument die
auf Kriterium C114 vom DCE kommende Clock verwendet.
Loop3 (C141): Auf “JA” einstellen, um das DCE dazu aufzufordern, einen lokalen
Daten-Loop (LL) auszuführen. Nur für DTE.
Die Loop LL - Aufforderung wird nur von den Schnittstellen V.35
und V.36 unterstützt.
1.3 UNFRAMED BER test
Um die Leitungsqualität zu testen, wählen Sie aus dem Menü der manuellen Tests
den UNFRAMED BER Test aus und geben Sie folgende Parameter ein:
Dauer: Legen Sie die Testdauer auf einen der vordefinierten Listenwerte fest oder
legen Sie eine individuelle Dauer fest.
Test Pass/Fail: Wählen Sie den BER - Wert, anhand dessen entschieden werden
soll, ob ein Test bestanden wird oder nicht. Durch Anwahl von G.821 wird das
Ergebnis mit den Qualitätsleistungen verglichen, die von G.821 gefordert werden.
Nur für Leitungsgeschwindigkeit von 64Kbit/s.
Fehler einfügen: Wählen Sie den BER-Wert, mit dem Fehler manuell oder
automatisch eingefügt werden.
Quick Guide VX2000
62
D
Bit Sequenz: Wählen Sie das zu verwendende pseudozufällige Modell aus der
Liste aus oder definieren Sie ein eigenes Modell.
HRX(%): Geben Sie hier den Variationsprozentsatz der Fehlergrenzen DM und
SES ein. Nur für Leitungsgeschwindigkeit von 64Kbit/s.
Fehlergrenze DM: Wählen Sie die Anzahl der Fehler pro Minute, mit der die
Angabe "gestörte Minute" erzeugt wird. Falls kein anderer Wert erforderlich ist,
wählen Sie den Default-Wert von G.821 (4). Nur für Leitungsgeschwindigkeit von
64Kbit/s.
Fehlergrenze SES: Wählen Sie die Anzahl der Fehler pro Sekunde, ab der ein
schwerwiegender Fehler erzeugt wird. Falls kein anderer Wert erforderlich ist,
wählen Sie den Default-Wert von G.821 (64). Nur für Leitungsgeschwindigkeit von
64Kbit/s.
Automatisch Drucken: Geben Sie hier an, zu welchen Bedingungen die
Testergebnisse automatisch gedruckt werden sollen. Es stehen folgende
Alternativen zur Verfügung:
Zeitabschnitt: 15 oder 30 Minuten
DM: wenn der DM über der Fehlergrenze liegt
1.3.1 Einen Unframed BER Test ausführen
Der VX2000 Adapter wird direkt über das D2000Pro gespeist.
Hierdurch wird die Dauer der Batterie verkürzt.
Der Test kann sowohl im Modus End-to-End als auch im Modus Single End
ausgeführt werden. Im ersten Fall ist ein weiteres D2000Pro/VX2000 am anderen
Leitungsende anzuschließen (Abbildung 1-2). Im Single-End Modus hingegen ist
eine Loop auf der Leitung zu erstellen. Die Loop kann vom DCE über das Kriterium
C141 angefordert werden, und zwar mit einem spezifischen, an das DCE
abzusendenden Befehl, oder auch indem eine physikalische Schleife zwischen TX-
und RX-Seite gelegt wird (siehe Abbildung 1-1).
Quick Guide VX2000
63
D
Abbildung 1-2 (end-to-end)
Nachdem Sie die Konfiguration des Unframed BER-Tests festgelegt haben, gehen
Sie folgendermaßen vor:
1
Hiermit wählen Sie ‘Diesen Setup zum Test verwenden’
auf der ersten Seite von KONFIGURATION.
2
Schließen Sie das Instrument wie auf dem Display
angegeben an und betätigen Sie die Taste CURSOR
RECHTS.
3
Hiermit starten Sie den Unframed BER test.
Die RUN LED leuchtet auf, und auf dem Display erscheinen die Testergebnisse.
4
Hiermit wechseln Sie von einer Ergebnisseite zur anderen.
Die Seiten zeigen für jeden Anruf die folgenden Ergebnisse an:
Die Zustandszeile zeigt den Testzustand an.
Bit Error Rate (BER)
Bits erhalten
Quick Guide VX2000
64
D
Fehlerbits abgesandt
Fehlerbits erhalten
Synchronverlust in der erhaltenen Sequenz
Testergebnis Pass/Fail
G.821-Daten: SES (Sekunden mit schwerwiegenden Fehlern), DM (gestörte
Minuten), ES (Fehlersekunden), US (nicht verfügbare Sekunden), als absolute
Werte und als Prozentsatz. Nur für Leitungsgeschwindigkeit von 64Kbit/s.
2 SMART STATUS
Für eine eingehende Beschreibung der Smart Status-Funktion, siehe das
entsprechende Kapitel im Anwenderhandbuch des Instruments.
2.1 Zustand der V/X - Schnittstelle
Die zweite Seite des Programmteils V/X - SCHNITTSTELLE zeigt an, welche Art
der Schnittstellentätigkeit verwendet wird.
1
Um zur zweiten Seite weiter zu gehen.
Durch Auswahl des der Schnittstelle entsprechenden Feldes und durch Druck auf
die ENTER - Taste kann eine Datenschleife gelegt werden. Das Instrument sendet
die von der entfernt gelegenen Stelle empfangenen Daten wieder ab. Zum
Entfernen der Schleife wird erneut der gleiche Vorgang vorgenommen. Die dritte
Seite zeigt den Zustand der Kriterien in Richtung DCE und in Richtung DTE an.
2
Um zur dritten Seite weiter zu gehen.
Quick Guide VX2000
65
D
Es werden folgende Kriterien angezeigt:
C103, C104,die vom DTE bzw. vom DCE übertragenen Daten.
C113, C115, vom DTE bzw. vom DCE übertragene Clock
C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD)
C141, Loop - Anforderung vom DTE an das DCE
Quick Guide VX2000
66
D
3 TECHNISCHE DATEN
SCHNITTSTELLEN
V.11
Entspricht
Steckerart
CCITT (ITU-T) Rec.V.11
15- poliger Stecker, ISO 4903
V.35
Entspricht
Steckerart
CCITT (ITU-T) Rec.V35
34 - poliger Stecker, ISO 2593
V.36
Entspricht
Steckerart
CCITT (ITU-T) Rec.V.36
37 - poliger Stecker, ISO 4902
Übertragungsclock
Struktur
Höchstgeschwindigkeit
N*64Kbps
2.048Kbps
Empfangsclock
Struktur
Höchstgeschwindigkeit
N*64Kbps
2.048Kbps
Kriterien
Verwaltung und Lesen
C108, C107, C105, C106, C109, C141
UMGEBUNGSDATEN
Abmessungen
Gewicht mit Batterie
Abmessungen (mm)
200 gr.
84 (w) x 150 (l) x 32 (d)
Stromversorgung
Hint
Das Zubehör wird über den Port Power
O t d D2000 PRO it St t
Quick Guide VX2000
67
D
Out des D2000 PRO mit Strom versorgt
Temperatur
Lagerung/Transport
Betriebstemperatur
Betriebsgrenzen
-40
o
C a +70
o
C
-5
o
C a +45
o
C
-10
o
C a +55
o
C
Relative Luftfeuchtigkeit (ohne
Kondenswasser)
93% RH @ 40
o
C
70% RH @ 55
o
C
Höhe ü.d.M.
Lagerung/Transport
Betriebsfähigkeit
12,000 m
4,500 m
Normen für die
Anwendersicherheit
EN 61010-1, EN 60950, EN 41003
EMC Normen
EN 55022, EN 55024, EN 61000-3-2 / -
3-3
CE Zeichen
Klasse B
4 UNKTIONSDATEN
VERFÜGBARE BETRIEBSWEISEN
Simulation
Kriterien ignorieren
Auswahlmodus
DTE, DCE
Teilnehmerbestimmt
Runtime
TEILNEHMERGESCHWINDIGKEIT
Übertragungsclock
Struktur
DTE
DCE
N*64Kbps
Extern (C114 -> C113)
Intern (C115)
Quick Guide VX2000
68
D
Interne Clockgeschwindigkeit
Maximale externe
Geschwindigkeit
Auswahlmodus
48, 64, 128, 192, 256, 320, 384, 512,
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
2.048Kbps
Runtime
Empfangsclock
Struktur
DTE
DCE
Interne Clockgeschwindigkeit
Maximale externe
Geschwindigkeit
Auswahlmodus
N*64Kbps
Extern (C115)
Intern (C114), regeneriert (C113)
48, 64, 128, 192, 256, 320, 384, 512,
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
2.048Kbps
Runtime
4.1 Pin Out
DTE Mode
1 - Nc
2 - C113A
3 - C115B
4 - C105
,
Control A
(
V.11
)
5 - C106
,
Indication A
(
V.11
)
6 - C103A
(
TxA
1
)
7 - Ground
8 - C114A
9 - C104A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C107
11 - C141
13 - Reserved
In
Out
-
C113B -14
Out
In
Out
Out
In
In
In
In
-
Out
C115A -15
Control B
(
V.11
)
-16
Indication B
V.11
-17
C103B
(
TxB
1
)
-18
C114B -19
C104B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C108 -24
Ground -25
Out
Out
Out
In
In
In
In
In
-
-
Quick Guide VX2000
69
D
DCE Mode
X.21bis/V.35 – 34 poliger Stecker (ISO2593) - DTE Modus
PIN KRITERIUM RICHTUNG
AA C114B In
Y C114A In
S C103B (TxB1) Out
P C103A (TxA1) Out
X C115B In
V C115A In
T C104B (RxB1) In
R C104A (RxA1) In
W C113B Out
U C113A Out
F C109 (DCD) In
H C108 (DTR) Out
E C107 (DSR) In
D C106 (CTS) In
C C105 (RTS) Out
1 - Nc
2 - C114A
3 - C115B
4 - C106
,
Indication A
(
V.11
)
5 - C105
,
Control A
(
V.11
)
6 - C104A
(
TxA
1
)
7 - Ground
8 - C115A
9 - C103A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C108
11 - Reserved
13 - Reserved
Out
Out
-
C114B -14
Out
Out
Out
Out
In
Out
In
Out
-
Out
C115A -15
Indication B
V.11
-16
Control B
(
V.11
)
-17
C104B
(
TxB
1
)
-18
C115B -19
C103B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C107 -24
Ground -25
Out
Out
-
In
Out
In
Out
In
-
-
Quick Guide VX2000
70
D
L C141 (LL) Out
B Ground -
X.21bis/V.36 – 37 poliger Stecker (ISO4902) - DTE-Modus
PIN KRITERIUM RICHTUNG
23 C114B In
5 C114A In
22 C103B (TxB1) Out
4 C103A (TxA1) Out
26 C115B In
8 C115A In
24 C104B (RxB1) In
6 C104A (RxA1) In
35 C113B Out
17 C113A Out
13 C109 (DCD) In
12 C108 (DTR) Out
11 C107 (DSR) In
9 C106 (CTS) In
7 C105 (RTS) Out
10 C141 (LL) Out
20, 25, 30,
37
Ground -
X.21/V.11 – 15 poliger Stecker (ISO4903) - DTE-Modus
PIN KRITERIUM RICHTUNG
9 C103B (TxB
1
) Out
Quick Guide VX2000
71
D
2 C103A (TxA
1
) Out
13 C115B In
6 C115A In
11 C104B (RxB
1
) In
4 C104A (RxA
1
) In
14 Byte timing A (n.a.) In
7 Byte timing B (n.a.) In
3 Control A Out
10 Control B Out
5 Indication A In
12 Indication B In
8 Ground -
1
Auf das D2000Pro bezogene Signale.
4.2 Optional Codes
KODEX BESCHREIBUNG
6100999171 Cable kit, Vortäuschung DTE
6100999172 Cable kit, Vortäuschung DCE
Quick Guide VX2000
72
F
VX2000
INTERFACE
MULTIPROCOLE
OPTION D2000PRO
MANUEL
D’UTILISATION
Toutes les informations contenues dans ce
document appartiennent à Aethra
®
Telecomunicazioni S.p.a., elles sont par
conséquent susceptibles d’être modifiées sans
aucun préavis et ne constituent aucun engagement
de la part de Aethra
®
Telecomunicazioni S.p.a.
© Copyright Aethra
®
Telecomunicazioni Spa 2002.
Tous droits réservés
Rév. 3/2.62 - Décembre 2002 Code 074042002ML
Ce manuel est composé par 20 pages
Quick Guide VX2000
73
F
Table des matières
1 INTRODUCTION.................................................................................... 75
1.1 ACCES A LA PAGE-ECRAN DES TESTS MANUELS ..................... 75
1.2 SETUP GÉNÉRAL............................................................................. 76
1.3 TEST UNFRAMED BER .................................................................... 78
1.3.1 EXÉCUTION D’UN TEST UNFRAMED BER .............................. 79
2 SMART STATUS.................................................................................... 81
2.1 ETAT INTERFACE V/X...................................................................... 81
3 SPECIFICATIONS TECHNIQUES ......................................................... 83
4 SPECIFICATIONS FONCTIONNELLES ................................................ 84
4.1 PIN OUT ............................................................................................ 85
4.2 CODES OPTIONNEL ........................................................................ 88
Quick Guide VX2000
74
F
NORMES DE SECURITE
Le passage d’un lieu froid à un lieu chaud peut produire la formation de
buée à l’intérieur de l’appareil. Dans ce cas, pour éviter tout mauvais
fonctionnement, on conseille d’attendre au moins 2 heures avant
d’alimenter l’appareil.
Eviter d’accéder aux parties internes de l’équipement (et/ou de
l'alimentateur).
Si des objets ou des liquides pénètrent à l’intérieur de l’appareil, il faut
débrancher immédiatement le cordon d’alimentation. Avant d’utiliser de
nouveau l’appareil, faites-le contrôler par un technicien spécialisé.
Pour l’assistance, contacter un technicien spécialisé.
Avant toute intervention, vérifier toujours que l’appareil est bien isolé et que
l’alimentation a bien été coupée.
En cas d’incendie, il est interdit d’utiliser de l’eau comme moyen
d’extinction.
PRECAUTIONS
ATTENTION:
De nombreux composants utilisés dans cet équipement sont sensibles
aux charges électrostatiques.
En cas de manipulation des câbles de connexion, couper l’alimentation
électrique et éviter tout contact direct avec les terminaux des
connecteurs.
En cas de manipulation des câbles de connexion, couper l’alimentation
électrique et éviter tout contact direct avec les terminaux des
connecteurs.
Le non respect de ces précautions pourrait endommager l’appareil de
façon permanente.
Pour garantir une protection constante en vue de la sécurité de
l’opérateur, utiliser exclusivement l’adaptateur secteur fourni avec
l’appareil.
Quick Guide VX2000
75
F
1 INTRODUCTION
A l’aide de l’option VX2000, le D2000Pro est en mesure d’effectuer des tests sur
des lignes WAN/datacom (réseau étendu/communication de données) avec débit
binaire jusqu’à 2.048 Mbit/s.
Grâce à la possibilité d’émuler tant l’équipement DTE (Data Terminal Equipment :
Equipement Terminal de Traitement de Données) que l’équipement DCE (Data
Communications Equipment : matériel de transmission de données), le D2000Pro
permet d’effectuer des essais de qualité, des taux d’erreurs sur les bits (BER), en
mode de bout en bout sur la ligne de données ou des vérifications vers l’usager
DTE (CSU (unité de signalisation de contrôle),routeur, ou un autre équipement à
réseau étendu).
La surveillance des critères et la possibilité de gérer les boucles locales (LL)
permettent d’étendre les contrôles sur la ligne de données.
Les interfaces supportées sont la V.35, V.36 et V.11 (X.21),
Figure 1-1 (single end)
Les paragraphes suivants décrivent les différents tests disponibles en utilisant
l’interface du D2000Pro, des informations ultérieures sur le D2000Pro sont
disponibles dans le manuel d’utilisation de l’appareil.
1.1 Accès à la page-écran des tests manuels
Pour choisir un test manuel:
1
Pour ouvrir le menu principal.
L’écran affiche la dernière configuration utilisée.
2
Pour sélectionner le champ ACCES.
Quick Guide VX2000
76
F
3
Sélectionner le type d’accès, INTERFACE V/X.
4
Pour sélectionner le champ MODE.
5
Pour sélectionner le mode de l’appareil, par ex. DTE
(ETTD).
La section inférieure de l’écran affiche la configuration de
réseau sélectionnée, le voyant DEL jaune, correspondant
au mode choisi, s’allume. On peut choisir entre DTE et
DCE.
6
Pour sélectionner le menu de choix des TESTS
MANUELS.
7
Pour sélectionner le test UNFRAMED BER.
Pour la connexion à la ligne, utiliser le câble approprié pour le
mode sélectionné. Dans le cas du mode DCE, il faut utiliser un
câble approprié qu’il faut commander séparément.
1.2 Setup Général
A l’aide de cette page on peut régler les paramètres de l’appareil que les différents
tests ont en commun.
Quick Guide VX2000
77
F
1
Pour sélectionner la page de SETUP GENERAL.
1
On peut sélectionner la page de SETUP GENERAL
même dans un test.
2
Pour sélectionner le champ voulu.
Pour l’accès V/X, on peut définir les paramètres suivants:
Type interface: Sélectionner le type d’interface utiliséé entre:
V.35, V.36, V.11 (X.21)
Débit de ligne: Sélectionner le débit de ligne, en Kbit/s, utilisé par l’appareil pour
transmettre les données. Uniquement si Horloge TX = Interne et mode = DCE
Ignore critères: Activer ou désactiver le contrôle des critères
NON, l’appareil gère et contrôle les critères C108, C107, C105, C106 et C109
Quick Guide VX2000
78
F
OUI, on désactive la gestion et la vérification des critères susdits entre DTE et
DCE
Horloge RX: Définir le type d’horloge utilisé pour recevoir les données; avec
HORLOGE RX: REGENERE, l’appareil échantillonne les données reçues avec
l’horloge provenant du DTE (C113). Uniquement DCE.
En mode DCE, la source pour l’horloge de transmission des
données est fixe et INTERNE, tandis qu’en mode DTE l’appareil
utilise l’horloge provenant du DCE sur le critère C114.
Loop3 (C141): Régler “OUI” pour demander au DCE d’exécuter une boucle locale
(LL) des données. Uniquement DTE.
La demande de boucle LL est supportée uniquement par les
interfaces V.35 et V.36.
1.3 Test UNFRAMED BER
Pour exécuter un test de qualité de la ligne, sélectionner à partir du menu des tests
manuels le test UNFRAMED BER et régler les paramètres suivants:
Durée: Sélectionner la durée du test à partir de la liste prédéfinie ou définir votre
propre durée
Test Succès/Echec: Sélectionner la valeur BER à utiliser pour déterminer la
condition de succès ou d’échec du test. Si on sélectionne G.821, le résultat est
comparé aux performances de qualité demandées par G.821. Uniquement pour
débit de ligne 64Kbit/s.
Injection erreur: Sélectionner la valeur BER utilisée pour l’injection d’erreurs, en
mode Manuel ou automatique
Séquence bit: Régler la séquence pseudo-aléatoire de bit à utiliser en la
sélectionnant à partir de la liste, ou définir votre propre modèle
HRX(%): Entrer le pourcentage de variation des seuils DM et SES. Uniquement
pour débit de ligne 64Kbit/s.
Quick Guide VX2000
79
F
Seuil DM: Sélectionner le nombre d’erreurs par minute à considérer dégradé.
Utiliser la valeur par défaut G.821 (4) s’il n’est pas nécessaire d’entrer une valeur
spécifique. Uniquement pour débit de ligne 64Kbit/s.
Seuil SES: Sélectionner le nombre d’erreurs par seconde à considérer gravement
erroné. Utiliser la valeur par défaut G.821 (64) s’il n’est pas nécessaire d’entrer une
valeur spécifique. Uniquement pour débit de ligne 64Kbit/s.
Impression automatique: Sélectionner la condition d’impression automatique pour
imprimer les résultats du test entre:
Intervalle de temps: toutes les 15 ou 30 minutes
DM: lorsqu’on dépasse le seuil DM
1.3.1 Exécution d’un test Unframed BER
L’adaptateur VX2000 est alimenté directement à partir du
D2000Pro, cela provoque une diminution de la durée de la
batterie.
On peut effectuer le test tant en mode de bout en bout qu’en mode local. Dans le
premier cas il faut mettre un autre D2000Pro/VX2000 à l’extrémité à distance de la
ligne (figure 1-2). Dans le mode local, il faut effectuer une boucle sur la ligne. On
peut demander la boucle au DCE avec le critère C141, à l’aide de la commande
spécifique à donner au DCE ou en exécutant une boucle physique entre le côté TX
et le côté RX (voir figure 1-1).
Figure 1-2 (end-to-end)
Après avoir réglé la configuration du test UNFRAMED BER, continuer de la
manière suivante:
1
Pour sélectionner ‘Utiliser ce setup pour le test’ dans la
première page de CONFIGURATION.
2
Connecter l’appareil comme affiché à l’écran et appuyer
sur la touche CURSEUR VERS LA DROITE.
Quick Guide VX2000
80
F
3
Pour lancer le test BER.
Le voyant LED RUN s’allume et les résultats du test sont affichés à l’écran.
4
Pour aller d’une page à l’autre des résultats.
Les pages indiquent les résultats suivants pour chaque appel:
La ligne d’état indique l’état du test.
Bit Error Rate (BER)
Bits reçus
Bits erronés envoyés
Bits erronés reçus
Perte de synchronisation sur la séquence reçue
Résultat du test SUCCES/ECHEC
sur la touche CURSEUR VERS LA DROITE.
Quick Guide VX2000
81
F
Données G.821: SES (secondes gravement erronées), DM (minutes dégradées),
ES (secondes erronées), US (secondes non disponibles), en valeur absolue et
en pourcentage. Uniquement pour le débit de ligne 64Kbit/s.
2 SMART STATUS
Pour la description complète de la fonction de Smart Status, voir le chapitre
spécifique dans le Manuel d’utilisation de l’appareil.
2.1 Etat interface V/X
La deuxième page relative à l’accès INTERFACE V/X, montre le type d’activité de
l’interface utilisée.
1
Pour passer à la deuxième page.
Si on sélectionne le champ relatif à l’interface et on appuie sur la touche ENTER,
on peut introduire une boucle sur les données, l’appareil enverra en transmission
les données reçues à partir de la boucle à distance. Exécuter la même opération
pour enlever la boucle.
La troisième page montre l’état des critères vers DCE et vers DTE
2
Pour passer à la troisième page.
Quick Guide VX2000
82
F
Les critères montrés sont:
C103, C104,données transmises respectivement à partir de DTE et de DCE
C113, C115, horloge transmise respectivement à partir de DTE et de DCE
C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD)
C141, demande de boucle à partir de DTE vers DCE
Quick Guide VX2000
83
F
3 SPECIFICATIONS TECHNIQUES
INTERFACES
V.11
Conforme à
Type de connecteur
CCITT (ITU-T) Rec.V.11
15 pôles mâle, ISO 4903
V.35
Conforme à
Type de connecteur
CCITT (ITU-T) Rec.V35
34 pôles mâle, ISO 2593
V.36
Conforme à
Type de connecteur
CCITT (ITU-T) Rec.V.36
37 pôles mâle, ISO 4902
Horloge de transmission
Structure
Vitesse maximale
N*64Kbps
2.048Kbps
Horloge de réception
Structure
Vitesse maximale
N*64Kbps
2.048Kbps
Critères
Gestion et lecture
C108, C107, C105, C106, C109, C141
CARACTERISTIQUES DU MILIEU
Dimensions
Poids avec batterie
Dimensions (mm)
200 gr.
84 (w) x 150 (l) x 32 (d)
Alimentation
Conseillée
L’accessoire est alimenté par la porte
t d D2000 PRO
Quick Guide VX2000
84
F
power out du D2000 PRO
Température
Emmagasinage/Transport
Température de fonctionnement
Limites d’efficacité
opérationnelle
-40
o
C a +70
o
C
-5
o
C a +45
o
C
-10
o
C a +55
o
C
Humidité relative (sans condensât)
93% RH @ 40
o
C
70% RH @ 55
o
C
Altitudes
Emmagasinage/Transport
Efficacité opérationnelle
12,000 mètres
4,500 mètres
Normes de sécurité pour
l’utilisateur
EN 61010-1, EN 60950, EN 41003
Normes EMC
EN 55022, EN 55024, EN 61000-3-2 / -
3-3
Marquage CE
Classe B
4 SPECIFICATIONS FONCTIONNELLES
MODES DE FONCTIONNEMENT DISPONIBLES
Simulation
Ignore critères
Mode de sélection
DTE, DCE
Défini pas l’utilisateur
Runtime
DEBIT BINAIRE UTILISATEUR
Horloge de transmission
Structure
DTE
DCE
N*64Kbps
Externe (C114 -> C113)
Interne (C115)
Quick Guide VX2000
85
F
Vitesse interne de l’horloge
Vitesse externe maximale
Mode de sélection
48, 64, 128, 192, 256, 320, 384, 512,
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
2.048Kbps
Runtime
Horloge de réception
Structure
DTE
DCE
Vitesse interne de l’horloge
Vitesse externe maximale
Mode de sélection
N*64Kbps
Externe (C115)
Interne (C114), Looped (C113)
48, 64, 128, 192, 256, 320, 384, 512,
640, 768, 960, 1.024, 1.280, 1.536,
1.920, 2.048 Kbps
2.048Kbps
Runtime
4.1 Pin Out
DTE Mode
1 - Nc
2 - C113A
3 - C115B
4 - C105
,
Control A
(
V.11
)
5 - C106
,
Indication A
(
V.11
)
6 - C103A
(
TxA
1
)
7 - Ground
8 - C114A
9 - C104A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C107
11 - C141
13 - Reserved
In
Out
-
C113B -14
Out
In
Out
Out
In
In
In
In
-
Out
C115A -15
Control B
(
V.11
)
-16
Indication B
V.11
-17
C103B
(
TxB
1
)
-18
C114B -19
C104B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C108 -24
Ground -25
Out
Out
Out
In
In
In
In
In
-
-
Quick Guide VX2000
86
F
DCE Mode
X.21bis/V.35 - connecteur à 34 pôles (ISO2593) - mode DTE
PIN CRITERE DIRECTION
AA C114B In
Y C114A In
S C103B (TxB1) Out
P C103A (TxA1) Out
X C115B In
V C115A In
T C104B (RxB1) In
R C104A (RxA1) In
W C113B Out
U C113A Out
F C109 (DCD) In
H C108 (DTR) Out
E C107 (DSR) In
D C106 (CTS) In
C C105 (RTS) Out
1 - Nc
2 - C114A
3 - C115B
4 - C106
,
Indication A
(
V.11
)
5 - C105
,
Control A
(
V.11
)
6 - C104A
(
TxA
1
)
7 - Ground
8 - C115A
9 - C103A
(
RxA
1
)
10 - C109 Byte timing B (V.11)
12 - C108
11 - Reserved
13 - Reserved
Out
Out
-
C114B -14
Out
Out
Out
Out
In
Out
In
Out
-
Out
C115A -15
Indication B
V.11
-16
Control B
(
V.11
)
-17
C104B
(
TxB
1
)
-18
C115B -19
C103B
(
RxB
1
)
-20
Byte timinig A (V.11) -21
22
23
C107 -24
Ground -25
Out
Out
-
In
Out
In
Out
In
-
-
Quick Guide VX2000
87
F
L C141 (LL) Out
B Terre -
X.21bis/V.36 - connecteur à 37 pôles (ISO4902) - mode DTE
PIN CRITERE DIRECTION
23 C114B In
5 C114A In
22 C103B (TxB1) Out
4 C103A (TxA1) Out
26 C115B In
8 C115A In
24 C104B (RxB1) In
6 C104A (RxA1) In
35 C113B Out
17 C113A Out
13 C109 (DCD) In
12 C108 (DTR) Out
11 C107 (DSR) In
9 C106 (CTS) In
7 C105 (RTS) Out
10 C141 (LL) Out
20, 25, 30,
37
Terre -
Quick Guide VX2000
88
F
X.21/V.11 - connecteur à 15 pôles (ISO4903) - mode DTE
PIN CRITERE DIRECTION
9 C103B (TxB
1
) Out
2 C103A (TxA
1
) Out
13 C115B In
6 C115A In
11 C104B (RxB
1
) In
4 C104A (RxA
1
) In
14 Byte timing A (n.a.) In
7 Byte timing B (n.a.) In
3 Contrôle A Out
10 Contrôle B Out
5 Indication A In
12 Indication B In
8 Terre -
1
Signaux se référant au D2000Pro.
4.2 Codes Optionnel
CODE DESCRIPTION
6100999171 Cable kit, simulation DTE
6100999172 Cable kit, simulation DCE

Transcripción de documentos

ENGLISH GB Quick guide Guida rapida Guide rapide Manual de istrucciones rapide Handbuch ITALIANO I FRANÇAIS F ESPAÑOL E DEUTSCH D VX2000 Multiprotocol Interface Option ENGLISH GB VX2000 MULTIPROTOCOL INTERFACE D2000PRO OPTION USER’S MANUAL The information contained in this document is the property of Aethra. It is subject to change without notice and it shall in no way be blinding for Aethra 2002 Copyright Aethra S.p.a. All right reserved. Release 3/2.62 – December 2002 Code 074042002ML This manual is composed of 18 pages Quick Guide VX2000 Index GB 1 INTRODUCTION .................................................................................... 7 1.1 OPENING THE MANUAL TEST SCREEN ....................................... 7 1.2 COMMON SETUP ............................................................................. 8 1.3 UNFRAMED BER TEST .................................................................... 10 1.3.1 RUNNING AN UNFRAMED BER TEST...................................... 11 2 SMART STATUS.................................................................................... 13 2.1 V/X INTERFACE STATUS................................................................. 13 3 TECHNICAL SPECIFICATIONS ............................................................ 13 4 FUNCTIONAL SPECIFICATIONS.......................................................... 16 4.1 PIN OUT ............................................................................................ 17 4.2 OPTIONAL CODES ........................................................................... 20 5 Quick Guide VX2000 SAFETY RULES GB The change from cold to hot environments can cause the formation of condense inside the device. To avoid malfunctioning, wait at least 2 hours before connecting the device to the supply mains. Do not access internal parts of the device (and/or of the power supply unit). If objects or liquids penetrate inside the device, immediately disconnect the power supply cable. Before using the device again, have it checked by specialised staff. Refer to qualified staff for service. In case of intervention, always check that the power supply has been completely and successfully disconnected. In case of fire, absolutely avoid using water to extinguish it. WARNINGS ATTENTION: Many of the components used in this device are sensitive to electrostatic charge. In case of manipulation of the connection cables, disconnect the power supply and avoid direct contacts with the connector terminals. When handling electronic components, to eliminate any static electricity touch a grounded surface. If possible, wear a grounding armband. Failure to comply with these warnings could cause permanent damage to device. To guarantee continuous protection for operator safety, only use the mains adapter supplied with the instrument. 6 Quick Guide VX2000 1 INTRODUCTION With the VX2000 option, the D2000Pro is able to perform tests over WAN/datacom lines with a bit rate up to 2.048 Mbit/s. Thanks to the possibility to emulate both DTE (Data Terminal Equipment) and DCE (Data Communications Equipment), the D2000Pro allows to carry out quality tests, bit error rate (BER), in end-to-end mode over datacom line, or checks toward the User’s DTE (CSU, router, or other WAN equipment). The criteria monitoring and the possibility to manage local loops (LL), allow to extend controls over datacom line. The interfaces supported are: V.35, V.36 and V.11 (X.21), Fig. 1-1 (single end) The following paragraphs refer to various tests available using the D2000Pro interface, further information about the D2000Pro are available in the User’s Manual of the device. 1.1 Opening the Manual Test Screen To select the manual test: Open the TEST MENU. 1 The last used setup appears on the screen. 2 Select the ACCESS field. 3 Select the type of access, V/X INTERFACE. 7 GB Quick Guide VX2000 4 Select the ACT AS field. 5 Select the instrument mode, e.g. DTE. GB The lower section of the screen shows the selected network configuration. The yellow LED that corresponds to the selected mode goes on.. It’s possible to choose between DTE and DCE 6 Select MANUAL TESTS. 7 Select the test UNFRAMED BER. In order to connect to the line, use the appropriate cable according to the selected mode. In case of DCE mode, an appropriate cable, to order separately, is needed. 1.2 Common Setup This page is used to setup the common parameters for the various tests. 1 8 To select the COMMON SETUP page Quick Guide VX2000 GB 1 The COMMON SETUP page can be selected from any test 2 Choose the desired field The following parameters can be defined for the V/X INTERFACE access: Interface type: Choose the interface to use among: • V.35, V.36, V.11 (X.21) Line rate: Select the line rate, in Kbit/s, used by the device to transmit the data. Only if Clock TX = Inside and mode = DCE Ignore criteria: Enable or disable the criteria control 9 Quick Guide GB VX2000 • NO, the device guarantees and controls the C108, C107, C105, C106 and C109i criteria • YES, the management and the check of these criteria, between DTE and DCE, is disabled Clock RX: Define the type of clock used to receive data; with CLOCK RX: LOOPED, the device samples data received with the clock coming from DTE (C113). Only DCE. In DCE mode, the clock TX is fixed at “INSIDE”, whereas in DTE mode, the device uses the clock coming from the DCE over C114 criterion. Loop3 (C141): Set “YES” to ask the DCE to perform a local loop (LL) of the data. Only DTE. The LL (local loop) request is supported by V.35 and V.36 interfaces only. 1.3 UNFRAMED BER Test In order to run a line quality test, select from the manual test menu, the UNFRAMED BER and set the following parameters: Duration: Choose the duration of the test. Select from the defined list or define your own duration Pass/Fail test: Choose the BER value. This value is used to determine the pass or fail test condition. Selecting G.821, the result is compared with the quality performance required by G.821. Only for line rate 64Kbit/s. Error injection: Choose the BER value used for manual or automatic bit error injection Bit sequence: Set the pseudo-random pattern to be used. Select from the list 10 Quick Guide VX2000 HRX(%): Enter the variation percentage for the DM and SES thresholds. Only for 1 channel bandwidth DM Threshold: Choose the number of errors per minute to consider it as degraded. Use the G.821 (4) default value when no other value is preferred. Only for line rate 64Kbit/s SES Threshold: Choose the number of errors per second to be considered as severely errored. Use the G.821 (64) default value when no other value is preferred. Only for line rate 64Kbit/s Auto print: Choose the autoprint condition for the test results between: • Time interval: every 15 or 30 minutes • DM: when the DM threshold value is exceeded 1.3.1 Running an Unframed BER Test VX2000 adapter is fed directly by the D2000Pro, this cause a decrease of the battery duration. The test can be carried out both end-to-end and single end mode. In the first case is necessary to put another D2000Pro/VX2000 at the remote end of the line (fig. 1-2). In single-end mode, is necessary to carry out a loop over the line. The loop can be request to DCE with C141 criterion, through a specific command given to the DCE or carrying out a physical loop between TX side and RX side (see figure 1-1). Fig. 1-2 (end-to-end) When you have defined the setup for the Unframed BER test, continue as follows: Select ‘Use this setup for testing’ in the first SETUP page. 1 2 Connect the instrument as displayed on the screen and press the RIGHT CURSOR key. 11 GB Quick Guide VX2000 GB Start the BER test. 3 The LED RUN goes on and the test results appear on the screen. Scroll through the result pages. 4 The pages show the following results for each call: The status line indicates the status of the test. • Bit Error Rate (BER) • Received bits • Errored bits transmitted • Errored bits received • Synchronization and time without synchronization expressed in h, m, s (S-loss). • Result of the PASS/FAIL test 12 Quick Guide • VX2000 G.821 data: SES (severely errored seconds), DM (degraded minutes), ES (errored seconds), US (unavailable seconds) in absolute value and percentage, result of the PASS/FAIL test according the G.821 quality targets. 2 SMART STATUS To have a complete description of the Smart Status feature, see the specific chapter in the D2000Pro User’s Manual. 2.1 V/X Interface status nd The 2 page, relative to V/X INTERFACE access, shows the activity of the used interface. Goes to page 2. 1 The Clock Rx value, is displayed on the Status pages only if the clock value has been set as ‘Looped’, in the common setup. Selecting the relative interface field and pushing ENTER, it is possible to insert a loop on the data, the device will send, in transmission, the data received from the remote. Perform the same operation to remove the loop. rd The 3 page shows the state of criteria toward DCE and DTE Goes to page 3. 2 13 GB Quick Guide VX2000 GB The criteria displayed are: • C103, C104, data transmitted respectively from DTE and from DCE • C113, C115, clock transmitted respectively from DTE and from DCE • C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD) • C141, loop request from DTE to DCE 3 TECHNICAL SPECIFICATIONS INTERFACES V.11 Conforms at CCITT (ITU-T) Rec.V.11 User’s connection 15 poles male, ISO 4903 Conforms at CCITT (ITU-T) Rec.V35 User’s connection 34 poles male, ISO 2593 Conforms at CCITT (ITU-T) Rec.V.36 User’s connection 37 poles male, ISO 4902 V.35 V.36 Transmission Clock Structure 14 N*64Kbps Quick Guide Maximum rate VX2000 2.048Kbps Reception Clock Structure N*64Kbps Maximum rate 2.048Kbps GB Criteria Management and reading C108, C107, C105, C106, C109, C141 ENVIRONMENTAL CHARACTERISTICS Dimension Weight, with battery ≅ 200 gr. Dimensions (mm) 84 (w) x 150 (l) x 32 (d) Power Hint Accessory is feed through D2000 power out port PRO Temperature Storage/Transport -40oC to +70oC Operating, nominal -5oC to +45oC Operating, limits -10oC to +55oC Humidity, non-condensing o ≤ 93% RH @ 40 C ≤ 70% RH @ 55oC Altitude Storage/transport 12,000 meters Operating 4,500 meters User's Safety Aspects EN 61010-1, EN 60950, EN 41003 EMC Aspects EN 55022, EN 55024, EN 61000-3-2 / 3-3 CE Marking Class B (residential devices) 15 Quick Guide VX2000 4 FUNCTIONAL SPECIFICATIONS GB OPERATING MODES AVAILABLE Simulation DTE, DCE Ignore criteria User defined Mode selection Runtime USER’S BIT RATE Transmission Clock Structure N*64Kbps DTE External (C114 -> C113) DCE Internal (C115) Internal clock rates 48, 64, 128, 192, 256, 320, 384, 512, 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps External maximum rate 2.048Kbps Mode selection Runtime Reception Clock Structure N*64Kbps DTE External (C115) DCE Internal (C114), Looped (C113) Internal clock rates 48, 64, 128, 192, 256, 320, 384, 512, 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps 2.048Kbps External maximum rate Mode selection 16 Runtime Quick Guide VX2000 4.1 Pin Out GB DTE Mode Out In In In Out In Out In Out Ground -25 C108 -24 23 22 Byte timinig A (V.11) -21 1 C104B (RxB ) -20 C114B -19 1 C103B (TxB ) -18 Indication B (V.11) -17 Control B (V.11) -16 C115A -15 C113B -14 13 - Reserved 12 - C107 11 - C141 10 - C109 Byte timing B (V.11) 1 9 - C104A (RxA ) 8 - C114A 7 - Ground 1 6 - C103A (TxA ) 5 - C106, Indication A (V.11) 4 - C105, Control A (V.11) 3 - C115B 2 - C113A 1 - Nc In Out In In In Out In Out In Out - DCE Mode Out Out In Out Out In Out Out Out Ground -25 C107 -24 23 22 Byte timinig A (V.11) -21 1 C103B (RxB ) -20 C115B -19 1 C104B (TxB ) -18 Control B (V.11) -17 Indication B (V.11) -16 C115A -15 C114B -14 13 - Reserved 12 - C108 11 - Reserved 10 - C109 Byte timing B (V.11) 1 9 - C103A (RxA ) 8 - C115A 7 - Ground 1 6 - C104A (TxA ) 5 - C105, Control A (V.11) 4 - C106, Indication A (V.11) 3 - C115B 2 - C114A 1 - Nc In Out In Out Out In Out Out Out - 17 Quick Guide VX2000 X.21bis/V.35 - 34 poles socket (ISO2593) – DTE mode GB PIN CRITERION DIRECTION AA C114B In Y C114A In S C103B (TxB1) Out P C103A (TxA1) Out X C115B In V C115A In T C104B (RxB1) In R C104A (RxA1) In W C113B Out U C113A Out F C109 (DCD) In H C108 (DTR) Out E C107 (DSR) In D C106 (CTS) In C C105 (RTS) Out L C141 (LL) Out B Ground - X.21bis/V.36 - 37 poles socket (ISO4902) - DTE mode 18 PIN CRITERION DIRECTION 23 C114B In 5 C114A In 22 C103B (TxB1) Out 4 C103A (TxA1) Out 26 C115B In Quick Guide VX2000 8 C115A In 24 C104B (RxB1) In 6 C104A (RxA1) In 35 C113B Out 17 C113A Out 13 C109 (DCD) In 12 C108 (DTR) Out 11 C107 (DSR) In 9 C106 (CTS) In 7 C105 (RTS) Out 10 C141 (LL) Out Ground - 20, 25, 30, 37 GB X.21/V.11 - 15 pole socket (ISO4903) - DTE mode PIN 9 CRITERION DIRECTION 1 Out 1 C103B (TxB ) 2 C103A (TxA ) Out 13 C115B In 6 C115A 11 In 1 In 1 C104B (RxB ) 4 C104A (RxA ) In 14 Byte timing A (n.a.) In 7 Byte timing B (n.a.) In 3 Control A Out 10 Control B Out 5 Indication A In 12 Indication B In 19 Quick Guide 8 GB 1 VX2000 Ground Signals referred to D2000Pro 4.2 Optional Codes CODE DESCRIPTION 6100999171 Cable kit, DTE simulation 6100999172 Cable kit, DCE simulation 20 - Quick Guide VX2000 I VX2000 MULTIPROTOCOL INTERFACE OPZIONE D2000PRO MANUALE D’USO Le informazioni contenute in questo documento sono di proprietà della Aethra® Telecomunicazioni S.p.a., sono soggette a modifiche senza preavviso e non rappresentano impegno da parte della Aethra® Telecomunicazioni S.p.a. © Copyright Aethra® Telecomunicazioni Spa 2002 Tutti i diritti riservati Rev. 3/2.62 – Dicembre 2002 Code 074042002ML Questo manuale è composto da 18 pagine 21 Quick Guide VX2000 Indice I 1 INTRODUZIONE .................................................................................... 24 1.1 APERTURA SCHERMATA DELLE PROVE MANUALI .................... 24 1.2 SETUP GENERALE .......................................................................... 25 1.3 PROVA UNFRAMED BER................................................................. 27 1.3.1 ESECUZIONE DI UNA PROVA UNFRAMED BER..................... 28 2 SMART STATUS.................................................................................... 30 2.1 STATO INTERFACCIA V/X ............................................................... 30 3 SPECIFICHE TECNICHE....................................................................... 32 4 SPECIFICHE FUNZIONALI.................................................................... 33 4.1 PIN OUT ............................................................................................ 34 4.2 CODICI OPZIONALI .......................................................................... 37 22 Quick Guide VX2000 NORME DI SICUREZZA Il passaggio da ambienti freddi ad ambienti caldi può determinare la formazione di condensa all'interno dell'apparato. In questi casi, per evitare malfunzionamenti, si consiglia di attendere almeno 2 ore prima di connettere l'apparato alla rete di alimentazione. I Evitare di accedere alle parti interne dell'apparato (e/o dell'alimentatore). In caso di penetrazione di oggetti o liquidi all'interno dell'apparato, scollegare immediatamente il cavo di alimentazione. Prima di riutilizzare l'apparato, farlo controllare da personale specializzato. Per l'assistenza rivolgersi a personale qualificato. In caso di intervento accertarsi sempre che l'apparato sia completamente ed efficacemente isolato dalla alimentazione. In caso di incendio, evitare in modo assoluto di usare acqua come mezzo estinguente. PRECAUZIONI Molti dei componenti utilizzati in questo apparato sono sensibili alle scariche elettrostatiche. Nel caso di eventuale manipolazione dei cavi di collegamento, disinserire l'alimentazione elettrica ed evitare contatti diretti con i terminali dei connettori. Nella necessità di dover maneggiare qualsiasi componente elettronico, eliminare l'eventuale elettricità statica di cui si potrebbe essere portatori, toccando un piano di massa per scaricarla a terra. Se possibile, indossare un bracciale a massa. L'inosservanza di queste precauzioni potrebbe causare danni permanenti all'apparato. Al fine di garantire una protezione continua per la sicurezza dell'operatore, utilizzare esclusivamente l'adattatore di rete fornito in dotazione con l'apparato. 23 Quick Guide VX2000 1 INTRODUZIONE I Tramite l'opzione VX2000, il D2000Pro è in grado di effettuare prove su linee WAN/datacom con bit rate fino a 2.048 Mbit/s. Grazie alla possibilità di emulare sia l'apparato DTE (Data Terminal Equipment) che il DCE (Data Communications Equipment), il D2000Pro permette di effettuare prove di qualità, bit error rate (BER), in modalità end-to-end sulla linea dati o verifiche verso il DTE utente (CSU, router, o altro apparato WAN). Il monitoraggio dei criteri e la possibilità di gestire i loop locali (LL) permettono di estendere i controlli sulla linea dati. Le interfacce supportate sono la V.35, V.36 e V.11 (X.21), Figura 1-1 (single end) I paragrafi che seguono fanno riferimento alle varie prove disponibili utilizzando l'interfaccia del D2000Pro, ulteriori informazioni sul D2000Pro sono disponibili sul manuale d'uso dello strumento. 1.1 Apertura schermata delle prove manuali Per scegliere una prova manuale: Per aprire il menu principale. 1 Il display visualizza l’ultima configurazione usata. 2 Per selezionare il campo ACCESSO. 3 Selezionare il tipo di accesso, INTERFACCIA V/X. 24 Quick Guide VX2000 4 Per selezionare il campo MODALITÀ. 5 Per selezionare il modo dello strumento, es. DTE. La sezione inferiore del display visualizza la configurazione di rete selezionata, il LED giallo corrispondente al modo scelto si accende. E’ possibile scegliere tra DTE e DCE. 6 Per selezionare il menu di scelta delle PROVE MANUALI. 7 Per selezionare la prova UNFRAMED BER. I Per la connessione alla linea, utilizzare il cavo opportuno alla modalità selezionata. Nel caso di modalità DCE, occorre utilizzare un apposito cavo ordinabile separatamente. 1.2 Setup Generale Tramite questa pagina è possibile impostare i parametri dello strumento che sono in comune tra le varie prove. 1 Per selezionare la pagina di SETUP GENERALE. 25 Quick Guide VX2000 I 1 È possibile selezionare la pagina di SETUP GENERALE anche all’interno di una prova. 2 Per selezionare il campo di interesse. Per l'accesso V/X, possono essere definiti i seguenti parametri: Tipo interfaccia: Selezionare il tipo di interfaccia utilizzata tra: • V.35, V.36, V.11 (X.21) Velocità di linea: Selezionare la velocità di linea, in Kbit/s, utilizzata dallo strumento per trasmettere i dati. Solo se Clock TX = Interno e modo = DCE Ignora criteri: Attivare o disattivare il controllo dei criteri 26 Quick Guide VX2000 • NO, lo strumento gestisce e controlla i criteri C108, C107, C105, C106 e C109 • SI, viene disabilitata la gestione e la verifica dei suddetti criteri tra DTE e DCE Clock RX: Definire il tipo di clock utilizzato per ricevere i dati; con CLOCK RX: RIGENERATO, lo strumento campiona i dati ricevuti con il clock proveniente dal DTE (C113). Solo DCE. I In modalità DCE, la sorgente per il clock di trasmissione dei dati è fisso a INTERNO, mentre in modalità DTE lo strumento utilizza il clock proveniente dal DCE sul criterio C114. Loop3 (C141): Impostare “SI” per richiedere al DCE di eseguire un loop locale (LL) dei dati. Solo DTE. La richiesta di loop LL è supportata solo dalle interfacce V.35 e V.36. 1.3 Prova UNFRAMED BER Per eseguire una prova di qualità della linea, selezionare dal menu delle prove manuali la prova UNFRAMED BER e impostare i seguenti parametri: Durata: Inserire il tempo di durata della prova dalla lista predefinita o definire la propria durata. Prova Pass/Fail: Selezionare il valore BER da utilizzare per determinare il superamento o il fallimento della prova. Selezionando G.821, il risultato viene confrontato con le performance di qualità richieste dalla G.821. Solo per velocità di linea 64Kbit/s. Iniezione errore: Selezionare il valore BER utilizzato per l’iniezione di errori, in modo manuale o automatico. Sequenza bit: Impostare la sequenza pseudocasuale di bit da utilizzare dalla lista, o definire il proprio modello. HRX(%):Inserisci la percentuale di variazione delle soglie DM e SES. Solo per velocità di linea 64Kbit/s. 27 Quick Guide I VX2000 Soglia DM: Selezionare il numero di errori al minuto per considerarlo degradato. Usare il valore di default G.821 (4) quando non è richiesto un altro valore. Solo per velocità di linea 64Kbit/s. Soglia SES: Selezionare il numero di errori al secondo per considerarlo severamente errato. Usare il valore di default G.821 (64) quando non è richiesto un altro valore. Solo per velocità di linea 64Kbit/s. Stampa automatica: Selezionare la condizione di stampa automatica per i risultati della prova tra: • Intervallo di tempo: ogni 15 o 30 minuti • DM: quando viene superata la soglia DM 1.3.1 Esecuzione di una prova Unframed BER L’adattatore VX2000 viene alimentato direttamente dal D2000Pro, questo provoca una diminuzione della durata della batteria. La prova può essere effettuata sia in modo end-to-end che in modo single end. Nel primo caso occorre posizionare un altro D2000Pro/VX2000 all'estremo remoto della linea (figura 1-2). In modo single-end, è necessario effettuare un loop sulla linea. Il loop può essere richiesto al DCE con il criterio C141, via specifico comando da dare al DCE o eseguendo un loop fisico tra lato TX e lato RX (vedi figura 1-1). Figura 1-2 (end-to-end) Una volta impostata la configurazione della prova UNFRAMED BER, continuare come indicato di seguito: Per selezionare ‘Usa questo setup per la prova’ nella 1 prima pagina di CONFIGURAZIONE. 2 28 Collegare lo strumento come visualizzato sul display e premere il tasto CURSORE DESTRO. Quick Guide VX2000 premere il tasto CURSORE DESTRO. I Per iniziare la prova BER. 3 Il LED RUN si accende e i risultati della prova compaiono sul display. Per muoversi tra le pagine dei risultati. 4 Le pagine mostrano i seguenti risultati per ciascuna chiamata: La riga di stato indica lo stato della prova. • Bit Error Rate (BER) • Bit ricevuti • Bit errati inviati • Bit errati ricevuti • Sincronizzazione e tempo senza sincronizzazione espresso in h, m, s, (S-loss) • Risultato del test PASS/FAIL 29 Quick Guide • I VX2000 Dati G.821: SES (secondi gravemente errati), DM (minuti degradati), ES (secondi errati), US (secondi non disponibili), in valore assoluto e percentuale, risultato del test PASS/FAIL secondo gli obbiettivi di qualità G.821. 2 SMART STATUS Per la descrizione completa della funzione di Smart Status, vedere lo specifico capitolo sul manuale d'uso dello strumento. 2.1 Stato interfaccia V/X La seconda pagina relativa all’accesso INTERFACCIA V/X, mostra il tipo di attività dell’interfaccia utilizzata. Per passare alla seconda pagina. 1 Il valore del Clock Rx, viene visualizzato nelle pagine di Status solo se il valore di clock è stato impostato come ‘Rigenerato’, nel setup generale. Selezionando il campo relativo all'interfaccia e premendo il tasto ENTER, è possibile inserire un loop sui dati, lo strumento invierà in trasmissione i dati ricevuti dal remoto. Eseguire la stessa operazione per rimuovere il loop. La terza pagina mostra lo stato degli criteri verso DCE e verso DTE Per passare alla terza pagina. 2 30 Quick Guide VX2000 I I criteri mostrati sono: • C103, C104,dati trasmessi rispettivamente dal DTE e dal DCE • C113, C115, clock trasmesso rispettivamente dal DTE e dal DCE • C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD) • C141, richiesta di loop dal DTE al DCE 31 Quick Guide VX2000 3 SPECIFICHE TECNICHE INTERFACCE I V.11 Conforme a CCITT (ITU-T) Rec.V.11 Tipo di connettore 15 poli maschio, ISO 4903 Conforme a CCITT (ITU-T) Rec.V35 Tipo di connettore 34 poli maschio, ISO 2593 Conforme a CCITT (ITU-T) Rec.V.36 Tipo di connettore 37 poli maschio, ISO 4902 V.35 V.36 Clock di trasmissione Struttura N*64Kbps Velocità massima 2.048Kbps Clock di ricezione Struttura N*64Kbps Velocità massima 2.048Kbps Criteri Gestione e lettura C108, C107, C105, C106, C109, C141 CARATTERISTICHE AMBIENTALI Dimensioni Peso con batteria ≅ 200 gr. Dimensioni (mm) 84 (w) x 150 (l) x 32 (d) Power Hint 32 L’accessorio è alimentato dalla porta t d l D2000 PRO Quick Guide VX2000 power out del D2000 PRO Temperatura Immagazzinamento/Trasporto o o -40 C a +70 C Temperatura di funzionamento -5oC a +45oC Limiti di operabilità -10oC a +55oC Umidità relativa (senza condensazione) I o ≤ 93% RH @ 40 C ≤ 70% RH @ 55oC Altitudine Immagazzinamento/Trasporto 12,000 metri Operabilità 4,500 metri Norme di sicurezza per l’utente EN 61010-1, EN 60950, EN 41003 Norme EMC EN 55022, EN 55024, EN 61000-3-2 / 3-3 CE Marking Classe B 4 SPECIFICHE FUNZIONALI MODALITÀ OPERATIVE DISPONIBILI Simulazione DTE, DCE Ignora criteri Definito da utente Modalità di selezione Runtime VELOCITÀ D’UTENTE Clock di trasmissione Struttura N*64Kbps DTE Esterno (C114 -> C113) DCE Interno (C115) Velocità interna del clock 48, 64, 128, 192, 256, 320, 384, 512, 640 768 960 1 024 1 280 1 536 33 Quick Guide VX2000 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps Massima velocità esterna 2.048Kbps Modalità di selezione I Runtime Clock di ricezione Struttura N*64Kbps DTE Esterno (C115) DCE Interno (C114), Looped (C113) Velocità interna del clock 48, 64, 128, 192, 256, 320, 384, 512, 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps Massima velocità esterna 2.048Kbps Modalità di selezione Runtime 4.1 Pin Out DTE Mode Out In In In Out In Out In Out 34 Ground -25 C108 -24 23 22 Byte timinig A (V.11) -21 1 C104B (RxB ) -20 C114B -19 1 C103B (TxB ) -18 Indication B (V.11) -17 Control B (V.11) -16 C115A -15 C113B -14 13 - Reserved 12 - C107 11 - C141 10 - C109 Byte timing B (V.11) 1 9 - C104A (RxA ) 8 - C114A 7 - Ground 1 6 - C103A (TxA ) 5 - C106, Indication A (V.11) 4 - C105, Control A (V.11) 3 - C115B 2 - C113A 1 - Nc In Out In In In Out In Out In Out - Quick Guide VX2000 DCE Mode Out Ground -25 C107 -24 23 22 Byte timinig A (V.11) -21 1 C103B (RxB ) -20 C115B -19 1 C104B (TxB ) -18 Control B (V.11) -17 Indication B (V.11) -16 C115A -15 C114B -14 Out In Out Out In Out Out Out 13 - Reserved 12 - C108 11 - Reserved 10 - C109 Byte timing B (V.11) 1 9 - C103A (RxA ) 8 - C115A 7 - Ground 1 6 - C104A (TxA ) 5 - C105, Control A (V.11) 4 - C106, Indication A (V.11) 3 - C115B 2 - C114A 1 - Nc In Out In Out Out In Out Out Out - I X.21bis/V.35 - connettore a 34 poli (ISO2593) - modo DTE PIN CRITERIO DIREZIONE AA C114B In Y C114A In S C103B (TxB1) Out P C103A (TxA1) Out X C115B In V C115A In T C104B (RxB1) In R C104A (RxA1) In W C113B Out U C113A Out F C109 (DCD) In H C108 (DTR) Out E C107 (DSR) In D C106 (CTS) In C C105 (RTS) Out 35 Quick Guide VX2000 L C141 (LL) Out B Ground - X.21bis/V.36 - connettore a 37 poli (ISO4902) - modo DTE I PIN CRITERIO DIREZIONE 23 C114B In 5 C114A In 22 C103B (TxB1) Out 4 C103A (TxA1) Out 26 C115B In 8 C115A In 24 C104B (RxB1) In 6 C104A (RxA1) In 35 C113B Out 17 C113A Out 13 C109 (DCD) In 12 C108 (DTR) Out 11 C107 (DSR) In 9 C106 (CTS) In 7 C105 (RTS) Out 10 C141 (LL) Out Ground - 20, 25, 30, 37 X.21/V.11 - connettore a 15 poli (ISO4903) - modo DTE PIN 9 36 CRITERIO DIREZIONE 1 C103B (TxB ) Out Quick Guide 1 2 C103A (TxA ) Out 13 C115B In 6 C115A 11 1 VX2000 In 1 In 1 C104B (RxB ) 4 C104A (RxA ) In 14 Byte timing A (n.a.) In 7 Byte timing B (n.a.) In 3 Control A Out 10 Control B Out 5 Indication A In 12 Indication B In 8 Ground - I Segnali riferiti al D2000Pro. 4.2 Codici opzionali CODICE DESCRIZIONE 6100999171 Kit cavi, simulazione DTE 6100999172 Kit cavi, simulazione DCE 37 Quick Guide VX2000 E VX2000 MULTIPROTOCOL INTERFACE OPCIÓN D2000PRO MANUAL DE USUARIO Las informaciones contenidas en este documento son propiedad de Aethra® Telecomunicazioni S.p.a., están sujetas a modificaciones sin aviso previo y no representan un compromiso por parte de Aethra® Telecomunicazioni S.p.a. © Copyright Aethra® Telecomunicazioni Spa 2002. Todos los derechos reservados Rev. 3/2.62 Diciembre 2002 Código 074042002ML Este manual está compuesto por 18 páginas 38 Quick Guide VX2000 Índice 1 INTRODUCCIÓN.................................................................................... 41 1.1 CÓMO SELECCIONAR UNA PRUEBA MANUAL ............................ 41 1.2 SETUP GENERAL............................................................................. 42 1.3 PRUEBA UNFRAMED BER............................................................... 44 1.3.1 REALIZACIÓN DE UNA PRUEBA UNFRAMED BER................. 45 2 SMART STATUS.................................................................................... 47 2.1 ESTADO INTERFAZ V/X................................................................... 47 3 ESPECIFICACIONES TÉCNICAS ......................................................... 49 4 ESPECIFICACIONES FUNCIONALES .................................................. 50 4.1 PIN OUT ............................................................................................ 51 4.2 CODIGOS OPCIÓNALES.................................................................. 54 E 39 Quick Guide VX2000 NORMAS DE SEGURIDAD El pasaje de ambientes fríos a calientes puede determinar la formación de condensación dentro del aparato. En estos casos, para evitar funcionamientos inadecuados, se aconseja esperar por lo menos 2 horas antes de conectar el aparato a la red de alimentación. No acceda a las piezas internas del aparato (y/o del alimentador). En caso de penetración de objetos o líquidos dentro del aparato, desconecte inmediatamente el cable de alimentación. Antes de utilizar nuevamente el aparato, hágalo controlar por personal especializado. E Para la asistencia utilice personal cualificado. En caso de intervención, asegúrese siempre de que el aparato se encuentre completa y eficazmente aislado de la alimentación. En caso de incendio, evite absolutamente el uso de agua como medio de extinción. PRECAUCIONES Muchos de los componentes utilizados en este aparato son sensibles a las descargas electrostáticas. En caso de manipulación de los cables de conexión, desconecte la alimentación eléctrica y evite cualquier contacto directo con los terminales de los conectores. En caso de que se deba manipular cualquier componente electrónico, elimine la eventual electricidad estática tocando una superficie de masa para descargarla. Si es posible, póngase un brazal de masa. El incumplimiento de estas precauciones podría causar daños permanentes al aparato. Para asegurar una protección continua para la seguridad del operador, utilice exclusivamente el adaptador de red suministrado con el aparato. 40 Quick Guide VX2000 1 INTRODUCCIÓN Mediante la opción VX2000 el D2000Pro puede realizar pruebas sobre líneas WAN/datacom con velocidad de transmisión de hasta 2.048 Mbit/s. Gracias a la posibilidad de emular tanto el aparato DTE (Data Terminal Equipment) como el DCE (Data Communications Equipment), el D2000Pro permite realizar pruebas de calidad, bit error rate (BER) de modo “end-to-end” sobre la línea de datos o verificaciones hacia el DTE de usuario (CSU, enrutador u otro aparato WAN). El control de los criterios y la posibilidad de gestionar los bucles locales (LL) permiten extender los controles sobre la línea de datos. Las interfaces soportadas son V.35, V.36 y V.11 (X.21), Figura 1-1 (single end) Los capítulos que siguen se refieren a las varias pruebas disponibles utilizando la interfaz del D2000Pro. Para informaciones sobre el D2000Pro véase el manual de usuario del instrumento. 1.1 Cómo seleccionar una prueba manual Para seleccionar una prueba manual: Para abrir el menú principal. 1 La pantalla visualiza la última configuración utilizada. 2 Para seleccionar el campo ACCESO. 3 Seleccione el tipo de acceso, INTERFAZ V/X. 41 E Quick Guide VX2000 4 Para seleccionar el campo ACTÚE COMO. 5 Para seleccionar el modo del instrumento, por ejemplo DTE. La parte inferior de la pantalla visualiza la configuración de red seleccionada. El LED de color amarillo correspondiente al modo seleccionado se enciende. Se puede elegir entre DTE y DCE. 6 Para seleccionar el menú de selección de las PRUEBAS MANUALES. 7 Para seleccionar la prueba UNFRAMED BER. E Para la conexión a la línea utilice el cable adecuado para el modo seleccionado. En modo DCE se necesita utilizar un cable específico a pedir separadamente. 1.2 Setup General En esta página se pueden definir los parámetros del instrumento comunes para las varias pruebas. Para seleccionar la página de SETUP GENERAL. 1 42 Quick Guide VX2000 1 La página de SETUP GENERAL puede seleccionarse también dentro de cualquier prueba. 2 Para seleccionar el campo de interés. E Para el acceso V/X pueden definirse los parámetros siguientes: Tipo interfaz: Seleccione el tipo de interfaz utilizado entre: • V.35, V.36, V.11 (X.21) Velocidad de línea: Seleccione la velocidad de línea en Kbit/s utilizada por el instrumento para transmitir los datos. Sólo si Clock TX = Interno y modo = DCE. Ignora criterios: Activar o desactivar el control de los criterios 43 Quick Guide VX2000 • NO, el instrumento gestiona y controla los criterios C108, C107, C105, C106 y C109 • SI, para desactivar la gestión y verificación de los criterios entre DTE y DCE Reloj RX: Definir el tipo de reloj utilizado para recibir los datos. Con CLOCK RX: REGENERADO el instrumento compara los datos recibidos con el reloj procedente del DTE (C113). Sólo DCE. E En modo DCE la fuente para el reloj de transmisión de los datos es fija a INTERNO. En modo DTE el instrumento utiliza el reloj procedente del DCE en el criterio C114. Bucle3 (C141): Seleccione “SI” para que el DCE realice un bucle local (LL) de los datos. Sólo DTE. La petición de bucle LL es soportada solamente por las interfaces V.35 y V.36. 1.3 Prueba UNFRAMED BER Para realizar una prueba de calidad de la línea seleccione la prueba UNFRAMED BER en el menú de las pruebas manuales y defina los parámetros siguientes: Duración: Seleccione la duración de la prueba en la lista predefinida o bien defina la propia duración. Prueba Pasa/Falla: Seleccione el valor BER utilizado para determinar la condición de prueba pasada o fallada. Seleccionando G.821 el resultado se compara con las prestaciones de calidad establecidas por G.821. Sólo para velocidad de línea 64Kbit/s. Inyección error: Seleccione el valor BER utilizado para la inyección de errores manual o automática. Secuencia de bit: Seleccione la secuencia pseudoaleatoria de bitios utilizada de la lista o bien defina el propio modelo. 44 Quick Guide VX2000 HRX(%): Ingrese el porcentaje de variación de los umbrales DM y SES. Sólo para velocidades de línea 64Kbit/s. Umbral DM: Seleccione el número de errores por minuto para considerarlo degradado. Utilice el valor por defecto G.821 (4) cuando no se requiere otro valor. Sólo para velocidad de línea 64Kbit/s. Umbral SES: Seleccione el número de errores por segundo para considerarlo severamente errado. Utilice el valor por defecto G.821 (64) cuando no se requiere otro valor. Sólo para velocidad de línea 64Kbit/s. Impresión automática: Seleccione la condición de impresión automática para imprimir los resultados de la prueba entre: • Intervalo de tiempo: cada 15 o 30 minutos • DM: cuando se supera el valor del umbral DM E 1.3.1 Realización de una prueba Unframed BER El adaptador VX2000 recibe alimentación directamente del D2000Pro. Esto reduce la duración de la batería. La prueba puede realizarse tanto de modo “end-to-end” como “single end”. En el primer caso se necesita colocar otro D2000Pro/VX2000 en la extremidad remota de la línea (figura 1-2). De modo “single-end” se necesita realizar un bucle sobre la línea. El bucle puede solicitarse al DCE con el criterio C141 mediante comando específico al DCE o realizando un bucle físico entre el lado TX y el lado RX (véase figura 1-1). Figura 1-2 (end-to-end) Una vez definida la configuración de la prueba UNFRAMED BER continúe como indicado a continuación: 45 Quick Guide VX2000 1 Para seleccionar ‘Utilice este setup para el test’ en la primera página de CONFIGURACIÓN. 2 Conecte el instrumento como visualizado en la pantalla y pulse la tecla CURSOR DERECHA. 3 Para empezar la prueba BER. E El LED RUN se enciende y los resultados de la prueba aparecen en la pantalla. Para moverse por las páginas de los resultados. 4 Las páginas muestran los resultados siguientes para cada llamada: La línea de estado indica el estado de la prueba. • Bit Error Rate (BER) • Bit recibidos • Bit errados transmitidos • Bit errados recibidos • Pérdida de sincronismo en la secuencia recibida 46 Quick Guide VX2000 • Resultado de la prueba PASA/FALLA • Datos G.821: SES (segundos gravemente errados), DM (minutos degradados), ES (segundos errados), US (segundos no disponibles), en valor absoluto y porcentaje. Sólo para velocidad de línea 64Kbit/s. 2 SMART STATUS Para la descripción completa de la función SmartStatus véase el capítulo correspondiente en el manual de usuario del instrumento. E 2.1 Estado interfaz V/X La segunda página relativa al acceso INTERFAZ V/X muestra el tipo de actividad de la interfaz utilizada. Para pasar a la segunda página. 1 Seleccionando el campo relativo a la interfaz y pulsando la tecla ENTER se puede realizar un bucle sobre los datos. El instrumento envía en transmisión los datos recibidos por el remoto. Realice la misma operación para remover el bucle. La tercera página muestra el estado de los criterios hacia DCE y hacia DTE Para pasar a la tercera página. 2 47 Quick Guide Los criterios visualizados son: • C103, C104, datos transmitidos respectivamente por el DTE y DCE • C113, C115, reloj transmitido respectivamente por el DTE y DCE • C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD) • C141, solicitud de bucle del DTE al DCE E 48 VX2000 Quick Guide VX2000 3 ESPECIFICACIONES TÉCNICAS INTERFACES V.11 Conforme a CCITT (ITU-T) Rec.V.11 Tipo de conector 15 polos macho, ISO 4903 E V.35 Conforme a CCITT (ITU-T) Rec.V35 Tipo de conector 34 polos macho, ISO 2593 Conforme a CCITT (ITU-T) Rec.V.36 Tipo de conector 37 polos macho, ISO 4902 V.36 Reloj de transmisión Estructura N*64Kbps Velocidad máxima 2.048Kbps Reloj de recepción Estructura N*64Kbps Velocidad máxima 2.048Kbps Criterios Gestión y lectura C108, C107, C105, C106, C109, C141 CARACTERÍSTICAS AMBIENTALES Dimensiones Peso con batería ≅ 200 gr. Dimensiones (mm) 84 (w) x 150 (l) x 32 (d) Alimentación Hint La opción recibe alimentación del puerto Power Out del D2000 PRO 49 Quick Guide VX2000 Temperatura Almacenamiento/Transporte -40oC a +70oC Temperatura de funcionamiento -5oC a +45oC Límites operativos -10oC a +55oC Humedad relativa (sin condensación) E o ≤ 93% RH @ 40 C ≤ 70% RH @ 55oC Altitud Almacenamiento/Transporte 12,000 metros Operación 4,500 metros Normas de seguridad para el usuario EN 61010-1, EN 60950, EN 41003 Normas EMC EN 55022, EN 55024, EN 61000-3-2 / 3-3 Marca CE Clase B 4 ESPECIFICACIONES FUNCIONALES MODOS OPERATIVOS DISPONIBLES Simulación DTE, DCE Ignora criterios Definido por el usuario Modo de selección Runtime VELOCIDAD DE USUARIO Reloj de transmisión 50 Estructura N*64Kbps DTE Externo (C114 -> C113) DCE Interno (C115) Velocidad interna del reloj 48, 64, 128, 192, 256, 320, 384, 512, 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps Quick Guide VX2000 Máxima velocidad externa 1.920, 2.048 Kbps Modo de selección 2.048Kbps Runtime Reloj de recepción Estructura N*64Kbps DTE Externo (C115) DCE Interno (C114), Looped (C113) Velocidad interna del reloj 48, 64, 128, 192, 256, 320, 384, 512, 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps Máxima velocidad externa 2.048Kbps Modo de selección Runtime E 4.1 Pin Out DTE Mode Out In In In Out In Out In Out Ground -25 C108 -24 23 22 Byte timinig A (V.11) -21 1 C104B (RxB ) -20 C114B -19 1 C103B (TxB ) -18 Indication B (V.11) -17 Control B (V.11) -16 C115A -15 C113B -14 13 - Reserved 12 - C107 11 - C141 10 - C109 Byte timing B (V.11) 1 9 - C104A (RxA ) 8 - C114A 7 - Ground 1 6 - C103A (TxA ) 5 - C106, Indication A (V.11) 4 - C105, Control A (V.11) 3 - C115B 2 - C113A 1 - Nc In Out In In In Out In Out In Out - 51 Quick Guide VX2000 DCE Mode Out E Ground -25 C107 -24 23 22 Byte timinig A (V.11) -21 1 C103B (RxB ) -20 C115B -19 1 C104B (TxB ) -18 Control B (V.11) -17 Indication B (V.11) -16 C115A -15 C114B -14 Out In Out Out In Out Out Out 13 - Reserved 12 - C108 11 - Reserved 10 - C109 Byte timing B (V.11) 1 9 - C103A (RxA ) 8 - C115A 7 - Ground 1 6 - C104A (TxA ) 5 - C105, Control A (V.11) 4 - C106, Indication A (V.11) 3 - C115B 2 - C114A 1 - Nc X.21bis/V.35 - conector de 34 polos (ISO2593) - modo DTE 52 PIN CRITERIO DIRECCIÓN AA C114B In Y C114A In S C103B (TxB1) Out P C103A (TxA1) Out X C115B In V C115A In T C104B (RxB1) In R C104A (RxA1) In W C113B Out U C113A Out F C109 (DCD) In H C108 (DTR) Out E C107 (DSR) In D C106 (CTS) In C C105 (RTS) Out In Out In Out Out In Out Out Out - Quick Guide VX2000 L C141 (LL) Out B Masa - X.21bis/V.36 - conector de 37 polos (ISO4902) - modo DTE PIN CRITERIO DIRECCIÓN 23 C114B In 5 C114A In 22 C103B (TxB1) Out 4 C103A (TxA1) Out 26 C115B In 8 C115A In 24 C104B (RxB1) In 6 C104A (RxA1) In 35 C113B Out 17 C113A Out 13 C109 (DCD) In 12 C108 (DTR) Out 11 C107 (DSR) In 9 C106 (CTS) In 7 C105 (RTS) Out 10 C141 (LL) Out Masa - 20, 25, 30, 37 E X.21/V.11 - conector de 15 polos (ISO4903) - modo DTE PIN 9 2 CRITERIO DIRECCIÓN 1 Out 1 Out C103B (TxB ) C103A (TxA ) 53 Quick Guide 13 C115B 6 C115A 11 E 1 VX2000 In In 1 In 1 C104B (RxB ) 4 C104A (RxA ) In 14 Byte timing A (n.a.) In 7 Byte timing B (n.a.) In 3 Control A Out 10 Control B Out 5 Indicación A In 12 Indicación B In 8 Masa - Señales referidas al D2000Pro. 4.2 Codigos Opciónales CODIGO DESCRIPCION 6100999171 Cable kit, simulación DTE 6100999172 Cable kit, simulación DCE 54 Quick Guide VX2000 VX2000 MULTIPROTOCOL INTERFACE D OPTION FÜR D2000PRO HANDBUCH Die in diesem Dokument enthaltenen Informationen sind Eigentum von Aethra® Telecomunicazioni S.p.a., können jederzeit ohne vorherige Mitteilung geändert werden und sind unverbindlich für Aethra® Telecomunicazioni S.p.a. © Copyright Aethra® Telecomunicazioni Spa 2002 Alle Rechte vorbehalten Rev. 3/2.62 - Dezember 2002 Code 074042002ML Dieses Handbuch besteht aus 18 Seiten 55 Quick Guide VX2000 INHALTSVERZEICHNIS 1 D EINLEITUNG .......................................................................................... 58 1.1 PROGRAMMSEITE DER MANUELLEN TESTS ÖFFNEN .............. 58 1.2 ALLGEMEINER SETUP .................................................................... 59 1.3 UNFRAMED BER TEST .................................................................... 61 1.3.1 EINEN UNFRAMED BER TEST AUSFÜHREN .......................... 62 2 SMART STATUS.................................................................................... 64 2.1 ZUSTAND DER V/X - SCHNITTSTELLE........................................... 64 3 TECHNISCHE DATEN ........................................................................... 66 4 UNKTIONSDATEN................................................................................. 67 4.1 PIN OUT ............................................................................................ 68 4.2 OPTIONAL CODES ........................................................................... 71 56 Quick Guide VX2000 SICHERHEITSVORSCHRIFTEN Wird das Gerät aus kühlen Räumen in warme Räume gebracht, kann in seinem Inneren Kondenswasser entstehen. Um Betriebsstörungen zu vermeiden, sollten Sie in solchen Fällen mindestens 2 Stunden warten, bevor Sie das Gerät an das Stromnetz anschlissen. Nicht ins Innere des Geräts (bzw. des Netzgeräts) greifen. Sollten Gegenstände oder Flüssigkeiten in das Innere des Geräts gelangen, sofort das Netzkabel herausziehen. Bevor Sie das Gerät wieder benutzen, lassen Sie es von einem Fachmann prüfen. Für den Kundendienst wenden Sie sich bitte an qualifiziertes Fachpersonal. D Bevor mit Reparaturarbeiten begonnen wird, überzeugen Sie sich bitte davon, dass die Spannungsversorgung zum Gerät tatsächlich komplett unterbrochen worden ist. Bei Feuer darf auf keinen Fall Wasser zum Löschen verwendet werden. VORSICHTSMASSNAHMEN ACHTUNG: Viele der in diesem Gerät vorhandenen Bauteile sind empfindlich gegenüber elektrostatischen Entladungen. Sollten die Anschlusskabel umgesteckt werden, Vorher die Spannungsversorgung unterbrechen und jeglichen Direktkontakt mit den Endstücken der Steckverbindungen vermeiden. Sollte sich die Notwendigkeit ergeben, eines der elektronischen Bauteile anzufassen, so befreien Sie sich bitte vorher von der Ihnen eventuell anhaftenden elektrostatischen Ladung durch Berühren einer geerdeten Oberfläche. Falls möglich, sollten Sie ein geerdetes Armband tragen. Eine mangelnde Berücksichtigung obiger Vorsichtsmassnahmen kann zur permanenten Beschädigung des Geräts führen. Um die kontinuierliche Sicherheit des Bedieners zu gewährleisten, ist ausschließlich der zusammen mit dem Gerät gelieferte Netzadapter zu verwenden. 57 Quick Guide VX2000 1 EINLEITUNG Mit der Option VX2000 ist das D2000Pro dazu in der Lage, Tests auf WAN/datacom Leitungen mit Bit Rates bis zu 2.048 Mbit/s durchzuführen. Dank der Möglichkeit, sowohl das DTE (Data Terminal Equipment) als auch das DCE (Data Communications Equipment) zu emulieren, ermöglicht es das D2000Pro, Qualitätstests bzw. Bit Error Rate (BER) Tests im End-to-End Modus auf Datenleitungen oder Tests mit dem Teilnehmer - DTE (CSU, Router oder ein anderes WAN-Gerät) durchzuführen. Die Überwachung der Kriterien und die Möglichkeit, lokale Loops (LL) zu verwalten, machen es möglich, auch die Datenlinie zu testen. Es werden folgende Schnittstellen unterstützt: V.35, V.36 und V.11 (X.21), D Abbildung 1-1 (single end) In nachfolgenden Absätzen werden die verschiedenen Tests beschrieben, die unter Verwendung der D2000Pro Schnittstelle durchgeführt werden können. Weitere Infos über das D2000Pro sind im Anwenderhandbuch des Instruments enthalten. 1.1 Programmseite der manuellen Tests öffnen So wird ein manueller Test gewählt: Um die Ausgangsseite zu öffnen. 1 Auf dem Display erscheint die zuletzt verwendete Konfiguration. 2 Um das ANSCHLUSS Feld zu wählen. 3 Anschlussart wählen, SCHNITTSTELLE V/X. 58 Quick Guide VX2000 4 Um das BETRIEBSWEISE (Modus) Feld zu wählen. 5 Um die Betriebsweise (Modus) des Instruments zu wählen, z.B. DTE. Im unteren Bereich des Displays erscheint die gewählte Netzkonfiguration. Die dem gewählten Modus entsprechende gelbe LED leuchtet auf. Es kann zwischen DTE und DCE gewählt werden. D 6 Um das Auswahlmenü der MANUELLEN TESTS zu öffnen. 7 Um den UNFRAMED BER Test zu wählen. Zum Anschluss an die Leitung verwenden Sie bitte ein Kabel, das dem gewählten Modus entspricht. Für den DCE Modus ist ein spezielles Kabel zu verwenden, das getrennt bestellt werden kann. 1.2 Allgemeiner setup Mit dieser Seite ist es möglich, diejenigen Parameter des Instruments einzugeben, die für alle Tests gleich bleiben. 1 Zum Öffnen der Seite ALLGEMEINER SETUP. 59 Quick Guide VX2000 1 Die Seite ALLGEMEINER SETUP kann auch innerhalb eines Tests geöffnet werden. 2 Zur Anwahl des gewünschten Feldes. D Für den V/X Anschluss können folgende Parameter festgelegt werden: Schnittstellenart: Wählen Sie die verwendete Schnittstellenart unter folgenden Möglichkeiten aus: • V.35, V.36, V.11 (X.21) Leitungsgeschwindigkeit: Wählen Sie die Leitungsgeschwindigkeit in Kbit/s, die vom Instrument dazu verwendet wird, die Daten zu übertragen. Nur bei Clock TX = Intern und Modus = DCE. 60 Quick Guide VX2000 Kriterien ignorieren: Kriterienkontrolle aktivieren oder deaktivieren • NEIN, das Instrument verwaltet und prüft folgende Kriterien: C108, C107, C105, C106 und C109 • JA, die Verwaltung und Prüfung obiger Kriterien wird zwischen DTE und DCE deaktiviert Clock RX: Festlegung der Clockart, die für den Datenempfang verwendet wird; bei CLOCK RX: REGENERIERT sampelt das Instrument die empfangenen Daten mit der vom DTE kommenden Clock (C113). Lediglich DCE. Im DCE Modus bleibt die Clock-Quelle für die Datenübertragung fest auf INTERN, während im DTE Modus das Instrument die auf Kriterium C114 vom DCE kommende Clock verwendet. Loop3 (C141): Auf “JA” einstellen, um das DCE dazu aufzufordern, einen lokalen Daten-Loop (LL) auszuführen. Nur für DTE. Die Loop LL - Aufforderung wird nur von den Schnittstellen V.35 und V.36 unterstützt. 1.3 UNFRAMED BER test Um die Leitungsqualität zu testen, wählen Sie aus dem Menü der manuellen Tests den UNFRAMED BER Test aus und geben Sie folgende Parameter ein: Dauer: Legen Sie die Testdauer auf einen der vordefinierten Listenwerte fest oder legen Sie eine individuelle Dauer fest. Test Pass/Fail: Wählen Sie den BER - Wert, anhand dessen entschieden werden soll, ob ein Test bestanden wird oder nicht. Durch Anwahl von G.821 wird das Ergebnis mit den Qualitätsleistungen verglichen, die von G.821 gefordert werden. Nur für Leitungsgeschwindigkeit von 64Kbit/s. Fehler einfügen: Wählen Sie den BER-Wert, mit dem Fehler manuell oder automatisch eingefügt werden. 61 D Quick Guide D VX2000 Bit Sequenz: Wählen Sie das zu verwendende pseudozufällige Modell aus der Liste aus oder definieren Sie ein eigenes Modell. HRX(%): Geben Sie hier den Variationsprozentsatz der Fehlergrenzen DM und SES ein. Nur für Leitungsgeschwindigkeit von 64Kbit/s. Fehlergrenze DM: Wählen Sie die Anzahl der Fehler pro Minute, mit der die Angabe "gestörte Minute" erzeugt wird. Falls kein anderer Wert erforderlich ist, wählen Sie den Default-Wert von G.821 (4). Nur für Leitungsgeschwindigkeit von 64Kbit/s. Fehlergrenze SES: Wählen Sie die Anzahl der Fehler pro Sekunde, ab der ein schwerwiegender Fehler erzeugt wird. Falls kein anderer Wert erforderlich ist, wählen Sie den Default-Wert von G.821 (64). Nur für Leitungsgeschwindigkeit von 64Kbit/s. Automatisch Drucken: Geben Sie hier an, zu welchen Bedingungen die Testergebnisse automatisch gedruckt werden sollen. Es stehen folgende Alternativen zur Verfügung: • Zeitabschnitt: 15 oder 30 Minuten • DM: wenn der DM über der Fehlergrenze liegt 1.3.1 Einen Unframed BER Test ausführen Der VX2000 Adapter wird direkt über das D2000Pro gespeist. Hierdurch wird die Dauer der Batterie verkürzt. Der Test kann sowohl im Modus End-to-End als auch im Modus Single End ausgeführt werden. Im ersten Fall ist ein weiteres D2000Pro/VX2000 am anderen Leitungsende anzuschließen (Abbildung 1-2). Im Single-End Modus hingegen ist eine Loop auf der Leitung zu erstellen. Die Loop kann vom DCE über das Kriterium C141 angefordert werden, und zwar mit einem spezifischen, an das DCE abzusendenden Befehl, oder auch indem eine physikalische Schleife zwischen TXund RX-Seite gelegt wird (siehe Abbildung 1-1). 62 Quick Guide VX2000 Abbildung 1-2 (end-to-end) Nachdem Sie die Konfiguration des Unframed BER-Tests festgelegt haben, gehen Sie folgendermaßen vor: Hiermit wählen Sie ‘Diesen Setup zum Test verwenden’ 1 auf der ersten Seite von KONFIGURATION. Schließen Sie das Instrument wie auf dem Display angegeben an und betätigen Sie die Taste CURSOR RECHTS. 2 D Hiermit starten Sie den Unframed BER test. 3 Die RUN LED leuchtet auf, und auf dem Display erscheinen die Testergebnisse. Hiermit wechseln Sie von einer Ergebnisseite zur anderen. 4 Die Seiten zeigen für jeden Anruf die folgenden Ergebnisse an: Die Zustandszeile zeigt den Testzustand an. • Bit Error Rate (BER) • Bits erhalten 63 Quick Guide VX2000 • Fehlerbits abgesandt • Fehlerbits erhalten • Synchronverlust in der erhaltenen Sequenz • Testergebnis Pass/Fail • G.821-Daten: SES (Sekunden mit schwerwiegenden Fehlern), DM (gestörte Minuten), ES (Fehlersekunden), US (nicht verfügbare Sekunden), als absolute Werte und als Prozentsatz. Nur für Leitungsgeschwindigkeit von 64Kbit/s. 2 SMART STATUS Für eine eingehende Beschreibung der Smart Status-Funktion, siehe das entsprechende Kapitel im Anwenderhandbuch des Instruments. D 2.1 Zustand der V/X - Schnittstelle Die zweite Seite des Programmteils V/X - SCHNITTSTELLE zeigt an, welche Art der Schnittstellentätigkeit verwendet wird. Um zur zweiten Seite weiter zu gehen. 1 Durch Auswahl des der Schnittstelle entsprechenden Feldes und durch Druck auf die ENTER - Taste kann eine Datenschleife gelegt werden. Das Instrument sendet die von der entfernt gelegenen Stelle empfangenen Daten wieder ab. Zum Entfernen der Schleife wird erneut der gleiche Vorgang vorgenommen. Die dritte Seite zeigt den Zustand der Kriterien in Richtung DCE und in Richtung DTE an. Um zur dritten Seite weiter zu gehen. 2 64 Quick Guide VX2000 Es werden folgende Kriterien angezeigt: • C103, C104,die vom DTE bzw. vom DCE übertragenen Daten. • C113, C115, vom DTE bzw. vom DCE übertragene Clock • C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD) • C141, Loop - Anforderung vom DTE an das DCE D 65 Quick Guide VX2000 3 TECHNISCHE DATEN SCHNITTSTELLEN V.11 Entspricht CCITT (ITU-T) Rec.V.11 Steckerart 15- poliger Stecker, ISO 4903 Entspricht CCITT (ITU-T) Rec.V35 Steckerart 34 - poliger Stecker, ISO 2593 Entspricht CCITT (ITU-T) Rec.V.36 Steckerart 37 - poliger Stecker, ISO 4902 V.35 D V.36 Übertragungsclock Struktur N*64Kbps Höchstgeschwindigkeit 2.048Kbps Empfangsclock Struktur N*64Kbps Höchstgeschwindigkeit 2.048Kbps Kriterien Verwaltung und Lesen C108, C107, C105, C106, C109, C141 UMGEBUNGSDATEN Abmessungen Gewicht mit Batterie ≅ 200 gr. Abmessungen (mm) 84 (w) x 150 (l) x 32 (d) Stromversorgung Hint 66 Das Zubehör wird über den Port Power O t d D2000 PRO it St t Quick Guide VX2000 Out des D2000 PRO mit Strom versorgt Temperatur Lagerung/Transport o o -40 C a +70 C Betriebstemperatur -5oC a +45oC Betriebsgrenzen -10oC a +55oC Relative Luftfeuchtigkeit (ohne Kondenswasser) o ≤ 93% RH @ 40 C ≤ 70% RH @ 55oC Höhe ü.d.M. Lagerung/Transport 12,000 m Betriebsfähigkeit 4,500 m Normen für die Anwendersicherheit EN 61010-1, EN 60950, EN 41003 EMC Normen EN 55022, EN 55024, EN 61000-3-2 / 3-3 CE Zeichen Klasse B D 4 UNKTIONSDATEN VERFÜGBARE BETRIEBSWEISEN Simulation DTE, DCE Kriterien ignorieren Teilnehmerbestimmt Auswahlmodus Runtime TEILNEHMERGESCHWINDIGKEIT Übertragungsclock Struktur N*64Kbps DTE Extern (C114 -> C113) DCE Intern (C115) 67 Quick Guide VX2000 Interne Clockgeschwindigkeit 48, 64, 128, 192, 256, 320, 384, 512, 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps Maximale externe Geschwindigkeit 2.048Kbps Runtime Auswahlmodus Empfangsclock D Struktur N*64Kbps DTE Extern (C115) DCE Intern (C114), regeneriert (C113) Interne Clockgeschwindigkeit 48, 64, 128, 192, 256, 320, 384, 512, 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps Maximale externe Geschwindigkeit 2.048Kbps Runtime Auswahlmodus 4.1 Pin Out DTE Mode Out In In In Out In Out In Out 68 Ground -25 C108 -24 23 22 Byte timinig A (V.11) -21 1 C104B (RxB ) -20 C114B -19 1 C103B (TxB ) -18 Indication B (V.11) -17 Control B (V.11) -16 C115A -15 C113B -14 13 - Reserved 12 - C107 11 - C141 10 - C109 Byte timing B (V.11) 1 9 - C104A (RxA ) 8 - C114A 7 - Ground 1 6 - C103A (TxA ) 5 - C106, Indication A (V.11) 4 - C105, Control A (V.11) 3 - C115B 2 - C113A 1 - Nc In Out In In In Out In Out In Out - Quick Guide VX2000 DCE Mode Out Ground -25 C107 -24 23 22 Byte timinig A (V.11) -21 1 C103B (RxB ) -20 C115B -19 1 C104B (TxB ) -18 Control B (V.11) -17 Indication B (V.11) -16 C115A -15 C114B -14 Out In Out Out In Out Out Out 13 - Reserved 12 - C108 11 - Reserved 10 - C109 Byte timing B (V.11) 1 9 - C103A (RxA ) 8 - C115A 7 - Ground 1 6 - C104A (TxA ) 5 - C105, Control A (V.11) 4 - C106, Indication A (V.11) 3 - C115B 2 - C114A 1 - Nc In Out In Out Out In Out Out Out - D X.21bis/V.35 – 34 poliger Stecker (ISO2593) - DTE Modus PIN KRITERIUM RICHTUNG AA C114B In Y C114A In S C103B (TxB1) Out P C103A (TxA1) Out X C115B In V C115A In T C104B (RxB1) In R C104A (RxA1) In W C113B Out U C113A Out F C109 (DCD) In H C108 (DTR) Out E C107 (DSR) In D C106 (CTS) In C C105 (RTS) Out 69 Quick Guide VX2000 L C141 (LL) Out B Ground - X.21bis/V.36 – 37 poliger Stecker (ISO4902) - DTE-Modus D PIN KRITERIUM RICHTUNG 23 C114B In 5 C114A In 22 C103B (TxB1) Out 4 C103A (TxA1) Out 26 C115B In 8 C115A In 24 C104B (RxB1) In 6 C104A (RxA1) In 35 C113B Out 17 C113A Out 13 C109 (DCD) In 12 C108 (DTR) Out 11 C107 (DSR) In 9 C106 (CTS) In 7 C105 (RTS) Out 10 C141 (LL) Out Ground - 20, 25, 30, 37 X.21/V.11 – 15 poliger Stecker (ISO4903) - DTE-Modus PIN 9 70 KRITERIUM 1 C103B (TxB ) RICHTUNG Out Quick Guide 1 2 C103A (TxA ) Out 13 C115B In 6 C115A 11 1 VX2000 In 1 In 1 C104B (RxB ) 4 C104A (RxA ) In 14 Byte timing A (n.a.) In 7 Byte timing B (n.a.) In 3 Control A Out 10 Control B Out 5 Indication A In 12 Indication B In 8 Ground - D Auf das D2000Pro bezogene Signale. 4.2 Optional Codes KODEX BESCHREIBUNG 6100999171 Cable kit, Vortäuschung DTE 6100999172 Cable kit, Vortäuschung DCE 71 Quick Guide VX2000 VX2000 INTERFACE MULTIPROCOLE F OPTION D2000PRO MANUEL D’UTILISATION Toutes les informations contenues dans ce document appartiennent à Aethra® Telecomunicazioni S.p.a., elles sont par conséquent susceptibles d’être modifiées sans aucun préavis et ne constituent aucun engagement de la part de Aethra® Telecomunicazioni S.p.a. © Copyright Aethra® Telecomunicazioni Spa 2002. Tous droits réservés Rév. 3/2.62 - Décembre 2002 Code 074042002ML Ce manuel est composé par 20 pages 72 Quick Guide VX2000 Table des matières 1 INTRODUCTION .................................................................................... 75 1.1 ACCES A LA PAGE-ECRAN DES TESTS MANUELS ..................... 75 1.2 SETUP GÉNÉRAL............................................................................. 76 1.3 TEST UNFRAMED BER .................................................................... 78 1.3.1 EXÉCUTION D’UN TEST UNFRAMED BER .............................. 79 2 SMART STATUS.................................................................................... 81 2.1 ETAT INTERFACE V/X...................................................................... 81 3 SPECIFICATIONS TECHNIQUES ......................................................... 83 4 SPECIFICATIONS FONCTIONNELLES ................................................ 84 4.1 PIN OUT ............................................................................................ 85 4.2 CODES OPTIONNEL ........................................................................ 88 F 73 Quick Guide VX2000 NORMES DE SECURITE Le passage d’un lieu froid à un lieu chaud peut produire la formation de buée à l’intérieur de l’appareil. Dans ce cas, pour éviter tout mauvais fonctionnement, on conseille d’attendre au moins 2 heures avant d’alimenter l’appareil. Eviter d’accéder aux parties internes de l’équipement (et/ou de l'alimentateur). Si des objets ou des liquides pénètrent à l’intérieur de l’appareil, il faut débrancher immédiatement le cordon d’alimentation. Avant d’utiliser de nouveau l’appareil, faites-le contrôler par un technicien spécialisé. Pour l’assistance, contacter un technicien spécialisé. Avant toute intervention, vérifier toujours que l’appareil est bien isolé et que l’alimentation a bien été coupée. En cas d’incendie, il est interdit d’utiliser de l’eau comme moyen d’extinction. F PRECAUTIONS ATTENTION: De nombreux composants utilisés dans cet équipement sont sensibles aux charges électrostatiques. En cas de manipulation des câbles de connexion, couper l’alimentation électrique et éviter tout contact direct avec les terminaux des connecteurs. En cas de manipulation des câbles de connexion, couper l’alimentation électrique et éviter tout contact direct avec les terminaux des connecteurs. Le non respect de ces précautions pourrait endommager l’appareil de façon permanente. Pour garantir une protection constante en vue de la sécurité de l’opérateur, utiliser exclusivement l’adaptateur secteur fourni avec l’appareil. 74 Quick Guide VX2000 1 INTRODUCTION A l’aide de l’option VX2000, le D2000Pro est en mesure d’effectuer des tests sur des lignes WAN/datacom (réseau étendu/communication de données) avec débit binaire jusqu’à 2.048 Mbit/s. Grâce à la possibilité d’émuler tant l’équipement DTE (Data Terminal Equipment : Equipement Terminal de Traitement de Données) que l’équipement DCE (Data Communications Equipment : matériel de transmission de données), le D2000Pro permet d’effectuer des essais de qualité, des taux d’erreurs sur les bits (BER), en mode de bout en bout sur la ligne de données ou des vérifications vers l’usager DTE (CSU (unité de signalisation de contrôle),routeur, ou un autre équipement à réseau étendu). La surveillance des critères et la possibilité de gérer les boucles locales (LL) permettent d’étendre les contrôles sur la ligne de données. Les interfaces supportées sont la V.35, V.36 et V.11 (X.21), F Figure 1-1 (single end) Les paragraphes suivants décrivent les différents tests disponibles en utilisant l’interface du D2000Pro, des informations ultérieures sur le D2000Pro sont disponibles dans le manuel d’utilisation de l’appareil. 1.1 Accès à la page-écran des tests manuels Pour choisir un test manuel: Pour ouvrir le menu principal. 1 L’écran affiche la dernière configuration utilisée. 2 Pour sélectionner le champ ACCES. 75 Quick Guide VX2000 3 Sélectionner le type d’accès, INTERFACE V/X. 4 Pour sélectionner le champ MODE. 5 Pour sélectionner le mode de l’appareil, par ex. DTE (ETTD). La section inférieure de l’écran affiche la configuration de réseau sélectionnée, le voyant DEL jaune, correspondant au mode choisi, s’allume. On peut choisir entre DTE et DCE. F 6 Pour sélectionner le menu de choix des TESTS MANUELS. 7 Pour sélectionner le test UNFRAMED BER. Pour la connexion à la ligne, utiliser le câble approprié pour le mode sélectionné. Dans le cas du mode DCE, il faut utiliser un câble approprié qu’il faut commander séparément. 1.2 Setup Général A l’aide de cette page on peut régler les paramètres de l’appareil que les différents tests ont en commun. 76 Quick Guide VX2000 1 Pour sélectionner la page de SETUP GENERAL. 1 On peut sélectionner la page de SETUP GENERAL même dans un test. F 2 Pour sélectionner le champ voulu. Pour l’accès V/X, on peut définir les paramètres suivants: Type interface: Sélectionner le type d’interface utiliséé entre: • V.35, V.36, V.11 (X.21) Débit de ligne: Sélectionner le débit de ligne, en Kbit/s, utilisé par l’appareil pour transmettre les données. Uniquement si Horloge TX = Interne et mode = DCE Ignore critères: Activer ou désactiver le contrôle des critères • NON, l’appareil gère et contrôle les critères C108, C107, C105, C106 et C109 77 Quick Guide • VX2000 OUI, on désactive la gestion et la vérification des critères susdits entre DTE et DCE Horloge RX: Définir le type d’horloge utilisé pour recevoir les données; avec HORLOGE RX: REGENERE, l’appareil échantillonne les données reçues avec l’horloge provenant du DTE (C113). Uniquement DCE. En mode DCE, la source pour l’horloge de transmission des données est fixe et INTERNE, tandis qu’en mode DTE l’appareil utilise l’horloge provenant du DCE sur le critère C114. Loop3 (C141): Régler “OUI” pour demander au DCE d’exécuter une boucle locale (LL) des données. Uniquement DTE. La demande de boucle LL est supportée uniquement par les interfaces V.35 et V.36. 1.3 Test UNFRAMED BER F Pour exécuter un test de qualité de la ligne, sélectionner à partir du menu des tests manuels le test UNFRAMED BER et régler les paramètres suivants: Durée: Sélectionner la durée du test à partir de la liste prédéfinie ou définir votre propre durée Test Succès/Echec: Sélectionner la valeur BER à utiliser pour déterminer la condition de succès ou d’échec du test. Si on sélectionne G.821, le résultat est comparé aux performances de qualité demandées par G.821. Uniquement pour débit de ligne 64Kbit/s. Injection erreur: Sélectionner la valeur BER utilisée pour l’injection d’erreurs, en mode Manuel ou automatique Séquence bit: Régler la séquence pseudo-aléatoire de bit à utiliser en la sélectionnant à partir de la liste, ou définir votre propre modèle HRX(%): Entrer le pourcentage de variation des seuils DM et SES. Uniquement pour débit de ligne 64Kbit/s. 78 Quick Guide VX2000 Seuil DM: Sélectionner le nombre d’erreurs par minute à considérer dégradé. Utiliser la valeur par défaut G.821 (4) s’il n’est pas nécessaire d’entrer une valeur spécifique. Uniquement pour débit de ligne 64Kbit/s. Seuil SES: Sélectionner le nombre d’erreurs par seconde à considérer gravement erroné. Utiliser la valeur par défaut G.821 (64) s’il n’est pas nécessaire d’entrer une valeur spécifique. Uniquement pour débit de ligne 64Kbit/s. Impression automatique: Sélectionner la condition d’impression automatique pour imprimer les résultats du test entre: • Intervalle de temps: toutes les 15 ou 30 minutes • DM: lorsqu’on dépasse le seuil DM 1.3.1 Exécution d’un test Unframed BER L’adaptateur VX2000 est alimenté directement à partir du D2000Pro, cela provoque une diminution de la durée de la batterie. On peut effectuer le test tant en mode de bout en bout qu’en mode local. Dans le premier cas il faut mettre un autre D2000Pro/VX2000 à l’extrémité à distance de la ligne (figure 1-2). Dans le mode local, il faut effectuer une boucle sur la ligne. On peut demander la boucle au DCE avec le critère C141, à l’aide de la commande spécifique à donner au DCE ou en exécutant une boucle physique entre le côté TX et le côté RX (voir figure 1-1). Figure 1-2 (end-to-end) Après avoir réglé la configuration du test UNFRAMED BER, continuer de la manière suivante: Pour sélectionner ‘Utiliser ce setup pour le test’ dans la 1 première page de CONFIGURATION. 2 Connecter l’appareil comme affiché à l’écran et appuyer sur la touche CURSEUR VERS LA DROITE. 79 F Quick Guide VX2000 sur la touche CURSEUR VERS LA DROITE. Pour lancer le test BER. 3 Le voyant LED RUN s’allume et les résultats du test sont affichés à l’écran. F Pour aller d’une page à l’autre des résultats. 4 Les pages indiquent les résultats suivants pour chaque appel: La ligne d’état indique l’état du test. • Bit Error Rate (BER) • Bits reçus • Bits erronés envoyés • Bits erronés reçus • Perte de synchronisation sur la séquence reçue • Résultat du test SUCCES/ECHEC 80 Quick Guide • VX2000 Données G.821: SES (secondes gravement erronées), DM (minutes dégradées), ES (secondes erronées), US (secondes non disponibles), en valeur absolue et en pourcentage. Uniquement pour le débit de ligne 64Kbit/s. 2 SMART STATUS Pour la description complète de la fonction de Smart Status, voir le chapitre spécifique dans le Manuel d’utilisation de l’appareil. 2.1 Etat interface V/X La deuxième page relative à l’accès INTERFACE V/X, montre le type d’activité de l’interface utilisée. Pour passer à la deuxième page. 1 F Si on sélectionne le champ relatif à l’interface et on appuie sur la touche ENTER, on peut introduire une boucle sur les données, l’appareil enverra en transmission les données reçues à partir de la boucle à distance. Exécuter la même opération pour enlever la boucle. La troisième page montre l’état des critères vers DCE et vers DTE Pour passer à la troisième page. 2 81 Quick Guide VX2000 Les critères montrés sont: • C103, C104,données transmises respectivement à partir de DTE et de DCE • C113, C115, horloge transmise respectivement à partir de DTE et de DCE • C105 (RTS), C106 (CTS), C107 (DSR), C108 (DTR), C109 (DCD) • C141, demande de boucle à partir de DTE vers DCE F 82 Quick Guide VX2000 3 SPECIFICATIONS TECHNIQUES INTERFACES V.11 Conforme à CCITT (ITU-T) Rec.V.11 Type de connecteur 15 pôles mâle, ISO 4903 Conforme à CCITT (ITU-T) Rec.V35 Type de connecteur 34 pôles mâle, ISO 2593 Conforme à CCITT (ITU-T) Rec.V.36 Type de connecteur 37 pôles mâle, ISO 4902 V.35 V.36 Horloge de transmission Structure N*64Kbps Vitesse maximale 2.048Kbps F Horloge de réception Structure N*64Kbps Vitesse maximale 2.048Kbps Critères Gestion et lecture C108, C107, C105, C106, C109, C141 CARACTERISTIQUES DU MILIEU Dimensions Poids avec batterie ≅ 200 gr. Dimensions (mm) 84 (w) x 150 (l) x 32 (d) Alimentation Conseillée L’accessoire est alimenté par la porte t d D2000 PRO 83 Quick Guide VX2000 power out du D2000 PRO Température Emmagasinage/Transport o o -40 C a +70 C Température de fonctionnement -5oC a +45oC Limites d’efficacité opérationnelle -10 C a +55 C Humidité relative (sans condensât) o o o ≤ 93% RH @ 40 C o ≤ 70% RH @ 55 C Altitudes F Emmagasinage/Transport 12,000 mètres Efficacité opérationnelle 4,500 mètres Normes de sécurité pour l’utilisateur EN 61010-1, EN 60950, EN 41003 Normes EMC EN 55022, EN 55024, EN 61000-3-2 / 3-3 Marquage CE Classe B 4 SPECIFICATIONS FONCTIONNELLES MODES DE FONCTIONNEMENT DISPONIBLES Simulation DTE, DCE Ignore critères Défini pas l’utilisateur Mode de sélection Runtime DEBIT BINAIRE UTILISATEUR Horloge de transmission 84 Structure N*64Kbps DTE Externe (C114 -> C113) DCE Interne (C115) Quick Guide VX2000 Vitesse interne de l’horloge 48, 64, 128, 192, 256, 320, 384, 512, 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps Vitesse externe maximale 2.048Kbps Mode de sélection Runtime Horloge de réception Structure N*64Kbps DTE Externe (C115) DCE Interne (C114), Looped (C113) Vitesse interne de l’horloge 48, 64, 128, 192, 256, 320, 384, 512, 640, 768, 960, 1.024, 1.280, 1.536, 1.920, 2.048 Kbps Vitesse externe maximale 2.048Kbps Mode de sélection Runtime 4.1 Pin Out F DTE Mode Out In In In Out In Out In Out Ground -25 C108 -24 23 22 Byte timinig A (V.11) -21 1 C104B (RxB ) -20 C114B -19 1 C103B (TxB ) -18 Indication B (V.11) -17 Control B (V.11) -16 C115A -15 C113B -14 13 - Reserved 12 - C107 11 - C141 10 - C109 Byte timing B (V.11) 1 9 - C104A (RxA ) 8 - C114A 7 - Ground 1 6 - C103A (TxA ) 5 - C106, Indication A (V.11) 4 - C105, Control A (V.11) 3 - C115B 2 - C113A 1 - Nc In Out In In In Out In Out In Out - 85 Quick Guide VX2000 DCE Mode Out Ground -25 C107 -24 23 22 Byte timinig A (V.11) -21 1 C103B (RxB ) -20 C115B -19 1 C104B (TxB ) -18 Control B (V.11) -17 Indication B (V.11) -16 C115A -15 C114B -14 Out In Out Out In Out Out Out 13 - Reserved 12 - C108 11 - Reserved 10 - C109 Byte timing B (V.11) 1 9 - C103A (RxA ) 8 - C115A 7 - Ground 1 6 - C104A (TxA ) 5 - C105, Control A (V.11) 4 - C106, Indication A (V.11) 3 - C115B 2 - C114A 1 - Nc X.21bis/V.35 - connecteur à 34 pôles (ISO2593) - mode DTE F 86 PIN CRITERE DIRECTION AA C114B In Y C114A In S C103B (TxB1) Out P C103A (TxA1) Out X C115B In V C115A In T C104B (RxB1) In R C104A (RxA1) In W C113B Out U C113A Out F C109 (DCD) In H C108 (DTR) Out E C107 (DSR) In D C106 (CTS) In C C105 (RTS) Out In Out In Out Out In Out Out Out - Quick Guide VX2000 L C141 (LL) Out B Terre - X.21bis/V.36 - connecteur à 37 pôles (ISO4902) - mode DTE PIN CRITERE DIRECTION 23 C114B In 5 C114A In 22 C103B (TxB1) Out 4 C103A (TxA1) Out 26 C115B In 8 C115A In 24 C104B (RxB1) In 6 C104A (RxA1) In 35 C113B Out 17 C113A Out 13 C109 (DCD) In 12 C108 (DTR) Out 11 C107 (DSR) In 9 C106 (CTS) In 7 C105 (RTS) Out 10 C141 (LL) Out Terre - 20, 25, 30, 37 F 87 Quick Guide VX2000 X.21/V.11 - connecteur à 15 pôles (ISO4903) - mode DTE PIN 9 1 DIRECTION 1 Out 1 C103B (TxB ) 2 C103A (TxA ) Out 13 C115B In 6 C115A 11 F CRITERE In 1 In 1 C104B (RxB ) 4 C104A (RxA ) In 14 Byte timing A (n.a.) In 7 Byte timing B (n.a.) In 3 Contrôle A Out 10 Contrôle B Out 5 Indication A In 12 Indication B In 8 Terre - Signaux se référant au D2000Pro. 4.2 Codes Optionnel CODE DESCRIPTION 6100999171 Cable kit, simulation DTE 6100999172 Cable kit, simulation DCE 88
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Aethra D2000Pro Manual de usuario

Tipo
Manual de usuario
Este manual también es adecuado para