Yamaha MY16-C El manual del propietario

Tipo
El manual del propietario

Este manual también es adecuado para

MY16-C
Owner’s Manual
INTERFACE CARD
1. IMPORTANT NOTICE: DO NOT MODIFY THIS
UNIT!
This product, when installed as indicated in the
instructions contained in this manual, meets FCC
requirements. Modifications not expressly
approved by Yamaha may void your authority,
granted by the FCC, to use the product.
2. IMPORTANT: When connecting this product to
accessories and/or another product use only high
quality shielded cables. Cable/s supplied with this
product MUST be used. Follow all installation
instructions. Failure to follow instructions could void
your FCC authorization to use this product in the
USA.
3. NOTE: This product has been tested and found to
comply with the requirements listed in FCC Regu-
lations, Part 15 for Class “B” digital devices. Com-
pliance with these requirements provides a
reasonable level of assurance that your use of this
product in a residential environment will not result
in harmful interference with other electronic
devices. This equipment generates/uses radio fre-
quencies and, if not installed and used according
to the instructions found in the users manual, may
cause interference harmful to the operation of
other electronic devices. Compliance with FCC
regulations does not guarantee that interference
will not occur in all installations. If this product is
found to be the source of interference, which can
be determined by turning the unit “OFF” and “ON”,
please try to eliminate the problem by using one of
the following measures:
Relocate either this product or the device that is
being affected by the interference.
Utilize power outlets that are on different branch
(circuit breaker or fuse) circuits or install AC line fil-
ter/s.
In the case of radio or TV interference, relocate/
reorient the antenna. If the antenna lead-in is 300
ohm ribbon lead, change the lead-in to co-axial
type cable.
If these corrective measures do not produce satis-
factory results, please contact the local retailer
authorized to distribute this type of product. If you
can not locate the appropriate retailer, please con-
tact Yamaha Corporation of America, Electronic
Service Division, 6600 Orangethorpe Ave, Buena
Park, CA90620
The above statements apply ONLY to those products distributed by Yamaha Corporation of America or its
subsidiaries.
* This applies only to products distributed by YAMAHA CORPORATION OF AMERICA. (class B)
FCC INFORMATION (U.S.A.)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
2
MY16-C
Owner’s Manual
ENGLISH
PRECAUTIONS
PLEASE READ CAREFULLY BEFORE PROCEEDING
* Please keep this manual in a safe place for future reference.
WARNING
Always follow the basic precautions listed below to avoid the possibility of serious injury or even death
from electrical shock, short-circuiting, damages, fire or other hazards. These precautions include, but are
not limited to, the following:
Before installing the MY16-C in an audio device please check to make sure that the device is compatible with the MY16-C, and
check possible restrictions regarding the maximum number of Yamaha and third-party expansion cards that can be
simultaneously installed. Refer to the operation manual supplied with the audio device, and/or the Yamaha Pro Audio web site
at: http://www.yamahaproaudio.com/
Do not install the MY16-C card in any Yamaha products not specified by Yamaha for use with the MY16-C to avoid possible
electrical shock, fire, or equipment damage.
Do not attempt to disassemble or modify the card. Do not apply excessive force to card connectors or other card components.
Mishandling of the card may lead to shock, fire hazard, or equipment failure.
Be sure to disconnect the power cable of the main unit before installing this card (in order to eliminate shock hazard).
Turn off all peripheral devices connected to the host device before installation, and unplug all related cables.
CAUTION
Always follow the basic precautions listed below to avoid the possibility of physical injury to you or others,
or damage to the device or other property. These precautions include, but are not limited to, the following:
Do not touch the metallic leads (pins) of the circuit board when handling the card. The pins are sharp and may cause hand cuts.
•Wear a pair of heavy gloves during installation to avoid scratching or cutting your hands on sharp edges.
Avoid touching exposed connectors and metal parts to minimize the possibility of bad connections.
Drain all static electricity from your clothing and body before handling the card. Static electricity can damage the card. Touch an
exposed metal part of the host device or other grounded object beforehand.
Do not drop the card or subject it to physical shock as this can result in breakage and/or malfunction.
Do not drop screws or other small parts inside the card. If power is applied while screws or similar metal objects are loose
inside the unit the card may malfunction or be damaged. If you cannot retrieve dropped objects yourself, refer the problem to
qualified Yamaha service personnel.
Yamaha cannot be held responsible for damage caused by improper use or modifications to the device, or data that is lost or destroyed.
C2
MY16-C_E.book Page 2 Tuesday, April 13, 2004 7:32 PM
3
MY16-C
Owner’s Manual
ENGLISH
About CobraNet™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
The MY16-C System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Controls & Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Clock Synchronization Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
MY16-C Card Installation Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Thank you for choosing the Yamaha MY16-C CobraNet™ INTERFACE CARD.
The MY16-C is a CobraNet™* expansion card for use with compatible Yamaha professional audio
equipment. Complying to CobraNet™ standards, the MY16-C allows transmission and reception of
up to 32 channels (16 in/16 out) of uncompressed digital audio data.
* CobraNet™: An audio networking system developed by Peak Audio (a division of Cirrus Logic,
Inc.) that allows real-time transmission and reception of multiple channels of uncompressed digital
audio signals via a Fast Ethernet (100 megabits/sec.) network. A single network cable can handle
a maximum of 64 channels (128 channels bidirectional) of audio data.
The Peak Audio home page can be viewed on the web at:
http://www.peakaudio.com/
In order to take full advantage of the advanced features and performance provided by the MY16-C
card we urge you to read this manual thoroughly, and keep it in a safe place for further reference.
Before installing the MY16-C in an audio device please check to make sure that the device is
compatible with the MY16-C, and check possible restrictions regarding the maximum number of
Yamaha and third-party expansion cards that can be simultaneously installed.
The Yamaha Pro Audio web site is at:
http://www.yamahaproaudio.com/
• MY16-C card
• This manual
The illustrations in this document are for instructional purposes, and may appear somewhat different from the actual equipment.
CobraNet and Peak Audio are trademarks of Cirrus Logic, Inc.
Ethernet is a trademark of Xerox Corporation.
All other trademarks are the property of their respective holders and are hereby acknowledged.
Table of contents
Greetings
Package Contents
1
table of contents.fm Page 3 Wednesday, April 14, 2004 5:39 PM
4
MY16-C
Owner’s Manual
ENGLISH
CobraNet is …
An audio networking system developed by Peak Audio (a division of Cirrus Logic, Inc.) that allows
real-time transmission and reception of uncompressed digital audio signals via a Fast Ethernet
network cable. The network can simultaneously handle up to 64 input and output channels, for a
total of 128 channels (64 channels if repeater hubs are used). The maximum number of channels
than can be handled in practical situations may be lower due to performance limitations imposed
by the equipment used and the condition of the audio signal.
Currently, the CobraNet network will handle 16, 20, or 24-bit audio at sampling rates of 48 or 96 kHz.
The CobraNet network is capable of transmitting control data at the same time as the audio
signals. The types of control data transmitted are determined by the equipment used.
The CobraNet network imposes a 5.33-millisecond (2.67 milliseconds or 1.33 milliseconds with
some settings) latency on transferred audio signals.
Refer to the Peak Audio home page for more details:
http://www.peakaudio.com/
Bundles
Audio is transmitted over the CobraNet network in units known as “bundles.” These bundles are
processed at the receiving end to reconstitute the original audio signals. In the case of the MY16-C
a bundle can contain from 3 to 8 channels. Each bundle is identified by a number from 0 to 65,279,
and audio transmission via the network becomes possible when the same bundle number is
specified at both the transmitting and receiving devices. Bundles can be transmitted and received
over the entire network as long as sufficient network resources are available. The system is
designed so that each device can transmit and receive up to 8 bundles simultaneously, but the
actual number of bundles that can be handled will depend on the capabilities of the equipment
used. The MY16-C can be set to handle 2 transmit bundle numbers and 2 receive bundle
numbers. The bundle numbers can be specified via the rotary switches on the MY16-C card itself,
or via the device or software used by the device in which the card is installed. The procedure for
setting the MY16-C bundle numbers is described in the "Controls & Functions" section on page 8.
About
2
MY16-C_E.book Page 4 Tuesday, April 13, 2004 7:32 PM
5
MY16-C
Owner’s Manual
ENGLISH
Multicast Bundles and Unicast Bundles
Two types of bundle can be used with CobraNet: “multicast” bundles and "unicast" bundles.
Multicast bundles can be transmitted from a single device to all devices on the network, while
unicast bundles are transferred from a single transmitting device to a single receiving device or a
limited number of receiving devices.
Unicast bundles are only sent to devices which have been set to the same bundle number as the
transmitting device. Multicast bundles are sent to all devices on the network regardless of their
settings, but only bundles with the specified bundle number(s) are processed. For this reason
multicast bundles make heavy use of network resources and it is recommended that the maximum
number of bundles be limited to 4 (32 channels). Unicast bundles should be employed when it is
necessary to handle 5 or more bundles at a time.
Different number ranges are used for multicast and unicast bundles: multicast bundles are
numbered 1 through 255, while unicast bundles are numbered 256 through 65,279.
Digital Audio Data
CobraNet Device
CobraNet Device
CobraNet Device CobraNet Device
C
B
A
D
Network
Multicast Bundles
Multicast bundles transmitted from device A are
sent to all devices on the network (B through D in
the example).
Digital Audio Data
CobraNet Device
CobraNet Device
CobraNet Device CobraNet Device
C
B
A
D
Network
Unicast Bundles
Unicast bundles are received only by devices set to
receive the same bundle numbers as the transmit
bundle number of the transmitting device A (device
D in this example).
3
MY16-C_E.book Page 5 Tuesday, April 13, 2004 7:32 PM
6
MY16-C
Owner’s Manual
ENGLISH
Conductor and Performers
On any CobraNet network one device generates a timing signal that all other devices receive and
are synchronized to. The device that generates the synchronization signal is known as the
“conductor,” while all other devices are “performers.”
The conductor for the network is automatically assigned and need not be specified by the operator.
When an MY16-C is assigned to be the conductor for the network, the LED indicator to the right of
the connector that is connected to the network will light orange. If the conductor fails for some
reason, conductor status is automatically switched to another device on the network.
Since the conductor transmits the synchronization signal to the performers via the network cable,
no separate word clock cables are required and the total number of cables used by the system is
kept to a minimum. Digital audio devices that are not connected to the network, however, will need
to receive a word clock signal from a device on the network in order to achieve synchronization.
n
Digital signals and control data are transmitted and received by all conductor and performer
devices on the CobraNet network.
CobraNet Cables and Hubs
Category-5 metal cables can be used for runs of up to 100 meters, while multimode optical fiber
cables can be used for runs of up to 2 kilometers.
“Cross” and “straight” Ethernet cables are available. “Cross” cables should be used for direct
connection between two devices. Hubs and "straight" cables are required to connect 3 or more
devices. Ethernet hubs are available in “repeater” and "switching" configurations. Switching hubs
are recommended for use on CobraNet networks. The use of repeater hubs can result in excessive
network traffic, thus reducing network efficiency.
It is best to use a repeater hub that has been tested and certified by Peak Audio.
A list is available at
http://www.peakaudio.com/cobranet/tested_ethernet.html.
E
Sync (Word Clock)
Performer (Receive)
Performer (Receive)
Performer
(Receive)
Conductor
(Transmit)
C
B
A
D
Network
External Digital Device
Conductors transmit the synchronization
signal that is received and used by
performers. Clock synchronization is
necessary to transfer digital audio data to
and from devices outside the CobraNet
network. In this example device B on the
CobraNet network sends the synchronization
signal to external device E.
4
MY16-C_E.book Page 6 Tuesday, April 13, 2004 7:32 PM
7
MY16-C
Owner’s Manual
ENGLISH
The internal signal flow of the MY16-C is shown in the illustration below.
16 audio inputs and 16 audio outputs are available, and for this example channels 1 ~ 8 are bundle
1, and channels 9 ~ 16 are bundle 2.
n
Depending on the setup, less than 8 channels may be handled by each bundle. The relationship between
the settings and the number of channels than can be handled by each bundle is shown below.
Settings vs. Number of Channels per Bundle
*1 Number of channels when 48-kHz channel pairs are combined to create single 96-kHz channels.
Channels per Bundle & Usable No. of Channels
The MY16-C System
Latency
Channels per Bundle
16 bit, 48kHz 20 bit, 48kHz 24 bit, 48kHz 16 bit, 96kHz 20 bit, 96kHz 24 bit, 96kHz
5.33 ms
8874
*1
4
*1
3
*1
2.66 ms
888 4
*1
4
*1
4
*1
1.33 ms
8884
*1
4
*1
4
*1
Channels per Bundle
Usable No. of Channels
Bundle1 Bundle2
8 1-8 9-16
7 1-7 9-15
4 1,3,5,7 9,11,13,15
3 1,3,5 9,11,13
MY16-C
CobraNet Connector1
CobraNet cable
CobraNet audio signal
Audio signal outside CobraNet network
CobraNet Device
DME64N/24N etc
Optional I/O Slot
CobraNet Audio Audio Convert
Control Data
Receive
Receive
Bundle1
Bundle1
Receive
Bundle1
Receive
Receive
Bundle2
Bundle2
Receive
Bundle2
Transmit
Transmit
Bundle2
Bundle2
Transmit
Bundle2
Transmit
Transmit
Bundle2
Bundle2
Transmit
Bundle2
5
MY16-C_E.book Page 7 Tuesday, April 13, 2004 7:32 PM
8
MY16-C
Owner’s Manual
ENGLISH
Panel Connectors and Switches
1
[PRIMARY] and 2
[SECONDARY] Connectors
These are 100Base-T Ethernet connectors. The MY16-C provides two Ethernet connectors to
allow construction of redundancy networks employing dual (primary and secondary) circuits. The
[PRIMARY] connector is for connection to the main circuit, while the [SECONDARY] connector is
for connection to the backup circuit.
If a failure occurs on the PRIMARY circuit (e.g. a cable failure, accidental disconnection, switching
hub failure, etc.) the SECONDARY circuit will automatically take over. Basic redundancy network
setup is described on page 17.
Use STP (Shielded Twisted Pair) cables to protect against electromagnetic interference.
3
[LINK/FAULT] Indicators
These are the LED indicators to the left of the [PRIMARY] and [SECONDARY] connectors.
These indicators will light when a network cable is connected to the corresponding connector. The
indicator for each connector will light green when a network cable is properly connected, and will
flash while data is being properly transferred via the corresponding connector. If an error occurs on
the connected network, the appropriate indicator will light or flash red.
If an indicator lights or flashes red, try disconnecting it from the corresponding Ethernet connector.
The indicator will go out if a cable, hub, or other device connected to the network has failed. If the
indicator remains lit or flashing even after the cable is disconnected, there may be a fault in the
MY16-C card itself. In this case please refer the problem to qualified Yamaha service personnel.
4
[IN USE/CONDUCT] Indicators
These are the indicators to the right of the [PRIMARY] and [SECONDARY] connectors. These
indicators will light when power has been properly applied to the MY16-C card. These indicators
normally light green, but will light orange when the MY16-C is operating as the
network conductor.
Controls & Functions
CobraNet INTERFACE CARD
MODEL MY16-C
MADE IN JAPAN
BUNDLE ASSIGNMENT
PRIMARY
SECONDARY
IN 1IN 2OUT 1OUT 2
Gr-LINK
Rd-FAULT
Gr-IN USE
Or-CONDUCT
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
12
6 5
34 34
6
MY16-C_E.book Page 8 Tuesday, April 13, 2004 7:32 PM
9
MY16-C
Owner’s Manual
ENGLISH
5
BUNDLE ASSIGNMENT [IN1] and [IN2] Rotary Switches
These switches set the receive bundle number for audio signals to be received over the CobraNet
network. The [IN1] switches specify the receive bundle 1 number, and the [IN2] switches specify
the receive bundle 2 number. Two rotary switches are used to specify each number. See "Bundle
Number Setting Procedure" on page 15 for details.
6
BUNDLE ASSIGNMENT [OUT1] and [OUT2] Rotary Switches
These switches set the transmit bundle number for audio signals to be transmitted over the CobraNet
network. The [OUT1] switches specify the transmit bundle 1 number, and the [OUT2] switches specify
the transmit bundle 2 number. Two rotary switches are used to specify each number. See "Bundle
Number Setting Procedure" on page 15 for details.
Circuit-board Switches
7
SERIAL ASSIGNMENT [RX] Rotary Switch
Sets the receive channel for the CobraNet serial control signal from channel 1 through channel 15.
The control signals are received from a device that has been set to the matching transmit-channel
number. No serial control reception occurs if this switch is set to “0”.
8
SERIAL ASSIGNMENT [TX] Rotary Switch
Sets the transmit channel for the CobraNet serial control signal from channel 1 through channel
15. The control signals are sent to devices that have been set to the matching receive-channel
number. No serial control transmission occurs if this switch is set to “0”.
When adjusting rotary switches please use a screwdriver with a blade that matches the switch
groove. Attempting to use a screwdriver that is too large or too small can damage the switch.
RX
TX
78
7
MY16-C_E.book Page 9 Tuesday, April 13, 2004 7:32 PM
10
MY16-C
Owner’s Manual
ENGLISH
DIP Switches
The DIP switches on the MY16-C circuit board can be used to set audio resolution, latency, the
clock synchronization mode, and clock frequency. All dip switches are OFF when the MY16-C is
initially shipped.
n
The RESERVED 1 and RESERVED 2 switches are reserved for functions to be
implemented in the future. Leave both of these switches OFF.
Audio Bits (BIT)
DIP switch 1 sets the audio bit depth.
Clock Frequency (Fs)
DIP switch 2 sets the audio clock frequency or sample rate.
n
Set all other MY16-C cards installed in the same device to the same clock frequency.
Set all CobraNet devices receiving and transmitting the same audio signals to the same
clock frequency.
BIT Audio Bit Depth
OFF 20 bit
ON 24 bit
Fs Clock Frequency
OFF 48 kHz
ON 96 kHz
1
2
3
4
5
6
7
8
O
N
No. Function
1 BIT
2Fs
3 LATENCY 1
4 LATENCY 2
5 CLOCK 1
6 CLOCK 2
7 RESERVED 1
8 RESERVED 2
8
MY16-C_E.book Page 10 Tuesday, April 13, 2004 7:32 PM
11
MY16-C
Owner’s Manual
ENGLISH
LATENCY 1/2
DIP switches 3 and 4 (LATENCY 1 and LATENCY 2) set the audio latency.
n
Set all CobraNet devices receiving and transmitting audio signals to the same latency.
Clock Synchronization Mode (CLOCK 1/2)
DIP switches 5 and 6 (CLOCK 1 and CLOCK 2) specify the clock synchronization mode to be
used. See "Clock Synchronization Modes" on page 12 for more information.
LATENCY 1 LATENCY 2 LATENCY
OFF OFF 5.33 ms
OFF ON 2.67 ms
ON OFF 1.33 ms
ON ON Reserved
CLOCK 1 CLOCK 2 Clock Synchronization Mode
OFF OFF Network synchronization
OFF ON Host synchronization 1
ON OFF Host synchronization 2
ON ON Reserved
9
MY16-C_E.book Page 11 Tuesday, April 13, 2004 7:32 PM
12
MY16-C
Owner’s Manual
ENGLISH
The MY16-C provides a selection of three clock synchronization modes: Network synchronization,
host synchronization 1, and host synchronization 2.
Network Synchronization
In this mode the MY16-C receives synchronization from the network. This is the normal
synchronization mode. When the MY16-C is set to network synchronization, make sure that the
audio device in which the MY16-C is installed is synchronized to the MY16-C clock.
Host Synchronization 1
Use this mode if the device in which the MY16-C is installed is synchronized to a clock signal other
than the CobraNet clock. When the Host Synchronization 1 mode is selected the MY16-C receives
synchronization from the device in which it is installed (the "host"), and that clock signal is then
supplied to the network. When the host Synchronization 1 mode is selected, make sure that the
host device is set to feed a clock signal to the MY16-C card.
n
When using the Host Synchronization 1 mode make sure that the frequency of the clock signal supplied to
the MY16-C is within ±50 ppm of 48 kHz or 96 kHz. Proper operation is not guaranteed with clock
frequencies outside this range, and problems with noise or instability may be encountered.
Clock Synchronization Modes
Network
N
N
N
Clock
DME64N/24N, PM5D etc
DME64N/24N
, PM5D etc DME64N/24N, PM5D etc
MY16-C
MY16-C
MY16-C
N :
Network Synchronization
Non-network Device
An example of network synchronization
H1
N
N
MY16-CMY16-C
MY16-C
N : Network Synchronization
H1 : Host Synchronization 1
Clock
Non-network Device
Network
DME64N/24N, PM5D etc
DME64N/24N
, PM5D etc DME64N/24N, PM5D etc
Examples of host synchronization 1
a.
10
MY16-C_E.book Page 12 Tuesday, April 13, 2004 7:32 PM
13
MY16-C
Owner’s Manual
ENGLISH
Host Synchronization 2
Use this mode if the MY16-C card is to be synchronized to the clock signal from another MY16-C
card installed in the same device. When more than one MY16-C cards are installed in the same
device and synchronization is to be received from the CobraNet network, set one of the installed
MY16-C cards to Network Synchronization, and the other card(s) in the same device to Host
Synchronization 2.
N
H1
H1
MY16-CMY16-C
MY16-C
H1
H1
N : Network Synchronization
H1 : Host Synchronization 1
Network
DME64N/24N,
PM5D etc
DME64N/24N
,
PM5D etc
DME64N/24N
,
PM5D etc
Clock
Non-network Device
b.
N
NH2
H2
MY16-C MY16-C
MY16-C
N : Network Synchronization
H2 : Host Synchronization 2
Network
PM5D etc
DME64N/24N
, PM5D etc DME64N/24N, PM5D etc
H2
H2
H2
H2
N
An example of host synchronization 2
11
MY16-C_E.book Page 13 Tuesday, April 13, 2004 7:32 PM
14
MY16-C
Owner’s Manual
ENGLISH
In some cases, all three synchronization modes are combined.
An example of all three synchronization modes used simultaneously.
H2
H2
N
N
H1
H1
MY16-C MY16-C
MY16-C
N : Network Synchronization
H1 : Host Synchronization 1
H2 : Host Synchronization 2
Network
DME64N/24N, PM5D etc
DME64N/24N
, PM5D etc DME64N/24N, PM5D etc
Clock
Non-network Device
a.
N : Network Synchronization
H1 : Host Synchronization 1
H2 : Host Synchronization 2
H1
H1
H1
H1
H1
H1
H1
H1
H2
H2
N
MY16-C MY16-C
MY16-C
Network
DME64N/24N,
PM5D etc
DME64N/24N
,
PM5D etc
DME64N/24N
,
PM5D etc
Clock
Non-network Device
b.
12
MY16-C_E.book Page 14 Tuesday, April 13, 2004 7:32 PM
15
MY16-C
Owner’s Manual
ENGLISH
Carefully read the precautions on page 2 before installing the MY16-C.
1 Set the MY16-C circuit-board DIP switches and rotary switches as required for your application.
Refer to "Circuit-board Switches" on page 9 for details about the switch settings. These
switches cannot be accessed while the MY16-C card is installed in its host device. If you need
to change the circuit board switch settings, turn power to the host device off, remove the MY16-
C card, change the settings as required, then re-install the MY16-C card in the device.
2 Install the MY16-C card in an appropriate card slot on the host device. Refer to the operation
manual of the host device for details. Make sure that the host device’s power is turned off before
installing the card.
Be sure to disconnect the power cable of the main unit before installing the MY16-C.
The screws function as part of the ground line, and should be tightened securely.
3 Connect the MY16-C card to another device on the CobraNet network using category-5 cable.
Refer to the "Connection Examples" on page 16.
4 Set the bundle numbers as required.
Bundle Number Setting Procedure
Using the hexadecimal system, the left rotary switch sets the most significant bits of the number while
the right switch sets the least significant bits. In short, the value of the left switch multiplied by 16 is
added to the value of the right switch to produce 256 different values.
The relationship between the switch settings and bundle numbers is shown in the chart below. For
example, if the left switch is set to "0" and the right switch is set to "A," the corresponding bundle
number would be "10" in decimal. If the left switch is set to "1" and the right switch to "5," the bundle
number would be 277 decimal.
When adjusting rotary switches please use a screwdriver with a blade that matches the switch
groove. Attempting to use a screwdriver that is too large or too small can damage the switch.
n
In some cases it is possible to set the bundle numbers from the device in which the MY16-
C card is installed, or via software running on the host device. In such cases the device’s
bundle settings take priority over the card’s rotary switches. It may also be possible to set
a wider range of bundle numbers than is available via the rotary switches.
MY16-C Card Installation Procedure
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
Example: Bundle No.10
Example: Bundle No.277
0A
15
Switch setting (Hexadecimal) Bundle number (Decimal)
00 No transfer
01 1
02 2
.
.
.
.
.
.
0F 15
10 272
11 273
.
.
.
.
.
.
FE 510
FF Ignored
13
MY16-C_E.book Page 15 Tuesday, April 13, 2004 7:32 PM
16
MY16-C
Owner’s Manual
ENGLISH
Connecting Two Devices
Connecting via a Hub
Connecting to a Mixer
Connection Examples
DME24N
DME64N
Audio signal and
control data
MY16-C
MY16-C
Cross Cable
96kHz
88.2kHz
48kHz
44.1kHz
EXT.
CLOCK
MID
MASTER
NETWORK
PEAK
SIGNAL
PEAK
SIGNAL
IN
OUT
SCENE NUMBER
123456 78
123456 78
Switching Hub
MY16-C MY16-C
MY16-C
MY16-C MY16-C MY16-C
96kHz
88.2kHz
48kHz
44.1kHz
EXT.
CLOCK
MID
MASTER
NETWORK
PEAK
SIGNAL
PEAK
SIGNAL
IN
OUT
SCENE NUMBER
12345678
12345678
96kHz
88.2kHz
48kHz
44.1kHz
EXT.
CLOCK
MID
MASTER
NETWORK
PEAK
SIGNAL
PEAK
SIGNAL
IN
OUT
SCENE NUMBER
12345678
12345678
DME24N DME64N DME64N
DME24N DME64N DME64N
Audio signal and
control data
Straight Cable
MY16-C MY16-C
MY16-C
MY16-C
96kHz
88.2kHz
48kHz
44.1kHz
EXT.
CLOCK
MID
MASTER
NETWORK
PEAK
SIGNAL
PEAK
SIGNAL
IN
OUT
SCENE NUMBER
12345678
12345678
Switching Hub
DME24N DME64N DME64N
Audio signal and
control data
Straight Cable
YAMAHA Digital Console
MY16-C
14
MY16-C_E.book Page 16 Tuesday, April 13, 2004 7:32 PM
17
MY16-C
Owner’s Manual
ENGLISH
Connecting to Other CobraNet Devices
n
Not compatible with ACU16-C or NHB32-C control signals.
CobraNet Redundancy Network
n
Redundancy Networks
Redundancy networks employ dual (primary and secondary) circuits. Communication usually
occurs over the primary circuit, but if a failure occurs on the primary circuit – cable failure,
accidental disconnection, switch failure, etc. – the secondary circuit will automatically take over.
Redundancy networks offer significantly higher reliability compared to single-circuit systems.
ACU16-C
NHB32-C
MY16-C
MY16-C
88
NETWORK HUB AND BRIDGE
LINK CONDUCT
LOCK
ERROR
96kHz
88.2kHz
48kHz
44.1kHz
EXT.
CLOCK
MID
MASTER
NETWORK
PEAK
SIGNAL
PEAK
SIGNAL
IN
OUT
SCENE NUMBER
12345678
12345678
Switching Hub
DME24N
Audio signal and
control data
Audio signal only
Audio signal and
control data
Audio signal only
Straight Cable
DME64N
MY16-C MY16-C
MY16-C MY16-C
Straight Cable
(Primary CobraNet)
Straight Cable
(Secondary CobraNet)
96kHz
88.2kHz
48kHz
44.1kHz
EXT.
CLOCK
MID
MASTER
NETWORK
PEAK
SIGNAL
PEAK
SIGNAL
IN
OUT
SCENE NUMBER
12345678
12345678
96kHz
88.2kHz
48kHz
44.1kHz
EXT.
CLOCK
MID
MASTER
NETWORK
PEAK
SIGNAL
PEAK
SIGNAL
IN
OUT
SCENE NUMBER
12345678
12345678
Switching Hub A Switching Hub B
DME24N
DME64N DME64N
DME24N
15
MY16-C_E.book Page 17 Tuesday, April 13, 2004 7:32 PM
18
MY16-C
Owner’s Manual
ENGLISH
DEUTSCH
FRANÇAIS
ESPAÑOL
Digital Input/Output Characteristics
<fs=48kHz>
<fs=96kHz>
General Specifications
CobraNet Ports (100Base-TX Ethernet, RJ-45)
Specifications
Terminal Format Latency Data Length Audio Connector
CobraNet
Primary/Secondary
CobraNet
5.33ms
20bit 16ch Input / 16ch Output
RJ45
24bit 14ch Input / 14ch Output
2.67ms
20bit 16ch Input / 16ch Output
24bit 16ch Input / 16ch Output
1.33ms
20bit 16ch Input / 16ch Output
24bit 16ch Input / 16ch Output
Min. Typ. Max.
Sampling Frequency Range 47.9976 48 48.0024
Terminal Format Latency Data Length Audio Connector
CobraNet
Primary/Secondary
CobraNet
5.33ms
20bit 8ch Input / 8ch Output
RJ45
24bit 6ch Input / 6ch Output
2.67ms
20bit 8ch Input / 8ch Output
24bit 8ch Input / 8ch Output
1.33ms
20bit 8ch Input / 8ch Output
24bit 8ch Input / 8ch Output
Min. Typ. Max.
Sampling Frequency Range 95.9952 96 96.0048
Dimensions (mm) 120 x 40 x 200 (W x H x D)
Net Weight (kg)
0.6
Temperature Range (°C)
10~35 (Operating Temperature Range)
-20~60 (Storage Temperature Range)
Accessories Owner’s Manual
Pin Connection
1
TxD+
2
TxD–
3
RxD+
4
Unused
5
Unused
6
RxD–
7
Unused
8
Unused
64
specifications.fm Page 18 Thursday, April 15, 2004 2:43 PM
19
MY16-C
Owner’s Manual
ENGLISH
DEUTSCH
FRANÇAIS
ESPAÑOL
Straight/Cross Cable Wiring Details
Dimensions
* Specifications and descriptions in this owner's manual are for information purposes only. Yamaha Corp. reserves the right to change or
modify products or specifications at any time without prior notice. Since specifications, equipment or options may not be the same in
every locale, please check with your Yamaha dealer.
* Die technischen Daten und Beschreibungen in dieser Bedienungsanleitung dienen nur der Information. Yamaha Corp. behält sich das
Recht vor, Produkte oder deren technische Daten jederzeit ohne vorherige Ankündigung zu verändern oder zu modifizieren. Da die
technischen Daten, das Gerät selbst oder Sonderzubehör nicht in jedem Land gleich sind, setzen Sie sich im Zweifel bitte mit Ihrem
Yamaha-Händler in Verbindung.
* Les caractéristiques techniques et les descriptions du mode d'emploi ne sont données que pour information. Yamaha Corp. se réserve
le droit de changer ou modifier les produits et leurs caractéristiques techniques à tout moment sans aucun avis. Du fait que les
caractéristiques techniques, les équipements et les options peuvent différer d’un pays à l'autre, adressez-vous au distributeur Yamaha
le plus proche.
* Las especificaciones y descripciones de este manual del propietario tienen sólo el propósito de servir como información. Yamaha Corp.
se reserva el derecho a efectuar cambios o modificaciones en los productos o especificaciones en cualquier momento sin previo aviso.
Puesto que las especificaciones, equipos u opciones pueden no ser las mismas en todos los mercados, solicite información a su
distribuidor Yamaha.
Straight Cables
Pins
1 —— 1
2 —— 2
3 —— 3
4 —— 4
5 —— 5
6 —— 6
7 —— 7
8 —— 8
Cross Cables
Pins
1 —— 3
2 —— 6
3 —— 1
4 —— 4
5 —— 5
6 —— 2
7 —— 7
8 —— 8
120
40
200
37
Unit: mm
65
specifications.fm Page 19 Monday, April 19, 2004 8:32 PM
U.R.G., Pro Audio & Digital Musical Instrument Division, Yamaha Corporation
© 2004 Yamaha Corporation
WC95460 404MWCP3.2-01A0
Printed in JAPAN
Yamaha Manual Library
http://www2.yamaha.co.jp/manual/english/
• This document is printed on chlorine free (ECF) paper with soy ink.
• Auf Umweltpapier mit Sojatinte gedruckt.
• Ce document a été imprimé sur du papier non blanchi au chlore avec de l'encre d'huile de soja.
• Este documento se ha impreso en papel sin cloro alguno, con tinta de soja.

Transcripción de documentos

INTERFACE CARD MY16-C Owner’s Manual FCC INFORMATION (U.S.A.) 1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product. 2. IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. Cable/s supplied with this product MUST be used. Follow all installation instructions. Failure to follow instructions could void your FCC authorization to use this product in the USA. 3. NOTE: This product has been tested and found to comply with the requirements listed in FCC Regulations, Part 15 for Class “B” digital devices. Compliance with these requirements provides a reasonable level of assurance that your use of this product in a residential environment will not result in harmful interference with other electronic devices. This equipment generates/uses radio frequencies and, if not installed and used according to the instructions found in the users manual, may cause interference harmful to the operation of other electronic devices. Compliance with FCC regulations does not guarantee that interference will not occur in all installations. If this product is found to be the source of interference, which can be determined by turning the unit “OFF” and “ON”, please try to eliminate the problem by using one of the following measures: Relocate either this product or the device that is being affected by the interference. Utilize power outlets that are on different branch (circuit breaker or fuse) circuits or install AC line filter/s. In the case of radio or TV interference, relocate/ reorient the antenna. If the antenna lead-in is 300 ohm ribbon lead, change the lead-in to co-axial type cable. If these corrective measures do not produce satisfactory results, please contact the local retailer authorized to distribute this type of product. If you can not locate the appropriate retailer, please contact Yamaha Corporation of America, Electronic Service Division, 6600 Orangethorpe Ave, Buena Park, CA90620 The above statements apply ONLY to those products distributed by Yamaha Corporation of America or its subsidiaries. * This applies only to products distributed by YAMAHA CORPORATION OF AMERICA. (class B) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. MY16-C_E.book Page 2 Tuesday, April 13, 2004 7:32 PM ENGLISH PRECAUTIONS PLEASE READ CAREFULLY BEFORE PROCEEDING * Please keep this manual in a safe place for future reference. WARNING Always follow the basic precautions listed below to avoid the possibility of serious injury or even death from electrical shock, short-circuiting, damages, fire or other hazards. These precautions include, but are not limited to, the following: • Before installing the MY16-C in an audio device please check to make sure that the device is compatible with the MY16-C, and check possible restrictions regarding the maximum number of Yamaha and third-party expansion cards that can be simultaneously installed. Refer to the operation manual supplied with the audio device, and/or the Yamaha Pro Audio web site at: http://www.yamahaproaudio.com/ • Do not install the MY16-C card in any Yamaha products not specified by Yamaha for use with the MY16-C to avoid possible electrical shock, fire, or equipment damage. • Do not attempt to disassemble or modify the card. Do not apply excessive force to card connectors or other card components. Mishandling of the card may lead to shock, fire hazard, or equipment failure. • Be sure to disconnect the power cable of the main unit before installing this card (in order to eliminate shock hazard). • Turn off all peripheral devices connected to the host device before installation, and unplug all related cables. CAUTION Always follow the basic precautions listed below to avoid the possibility of physical injury to you or others, or damage to the device or other property. These precautions include, but are not limited to, the following: • Do not touch the metallic leads (pins) of the circuit board when handling the card. The pins are sharp and may cause hand cuts. • Wear a pair of heavy gloves during installation to avoid scratching or cutting your hands on sharp edges. • Avoid touching exposed connectors and metal parts to minimize the possibility of bad connections. • Drain all static electricity from your clothing and body before handling the card. Static electricity can damage the card. Touch an exposed metal part of the host device or other grounded object beforehand. • Do not drop the card or subject it to physical shock as this can result in breakage and/or malfunction. • Do not drop screws or other small parts inside the card. If power is applied while screws or similar metal objects are loose inside the unit the card may malfunction or be damaged. If you cannot retrieve dropped objects yourself, refer the problem to qualified Yamaha service personnel. C2 Yamaha cannot be held responsible for damage caused by improper use or modifications to the device, or data that is lost or destroyed. 2 MY16-C Owner’s Manual ENGLISH table of contents.fm Page 3 Wednesday, April 14, 2004 5:39 PM Table of contents About CobraNet™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 The MY16-C System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Controls & Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Clock Synchronization Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 MY16-C Card Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Greetings Thank you for choosing the Yamaha MY16-C CobraNet™ INTERFACE CARD. The MY16-C is a CobraNet™* expansion card for use with compatible Yamaha professional audio equipment. Complying to CobraNet™ standards, the MY16-C allows transmission and reception of up to 32 channels (16 in/16 out) of uncompressed digital audio data. * CobraNet™: An audio networking system developed by Peak Audio (a division of Cirrus Logic, Inc.) that allows real-time transmission and reception of multiple channels of uncompressed digital audio signals via a Fast Ethernet (100 megabits/sec.) network. A single network cable can handle a maximum of 64 channels (128 channels bidirectional) of audio data. The Peak Audio home page can be viewed on the web at: http://www.peakaudio.com/ In order to take full advantage of the advanced features and performance provided by the MY16-C card we urge you to read this manual thoroughly, and keep it in a safe place for further reference. Before installing the MY16-C in an audio device please check to make sure that the device is compatible with the MY16-C, and check possible restrictions regarding the maximum number of Yamaha and third-party expansion cards that can be simultaneously installed. The Yamaha Pro Audio web site is at: http://www.yamahaproaudio.com/ Package Contents • MY16-C card • This manual The illustrations in this document are for instructional purposes, and may appear somewhat different from the actual equipment. CobraNet and Peak Audio are trademarks of Cirrus Logic, Inc. Ethernet is a trademark of Xerox Corporation. All other trademarks are the property of their respective holders and are hereby acknowledged. 1 MY16-C Owner’s Manual 3 MY16-C_E.book Page 4 Tuesday, April 13, 2004 7:32 PM ENGLISH About ■ CobraNet is … An audio networking system developed by Peak Audio (a division of Cirrus Logic, Inc.) that allows real-time transmission and reception of uncompressed digital audio signals via a Fast Ethernet network cable. The network can simultaneously handle up to 64 input and output channels, for a total of 128 channels (64 channels if repeater hubs are used). The maximum number of channels than can be handled in practical situations may be lower due to performance limitations imposed by the equipment used and the condition of the audio signal. Currently, the CobraNet network will handle 16, 20, or 24-bit audio at sampling rates of 48 or 96 kHz. The CobraNet network is capable of transmitting control data at the same time as the audio signals. The types of control data transmitted are determined by the equipment used. The CobraNet network imposes a 5.33-millisecond (2.67 milliseconds or 1.33 milliseconds with some settings) latency on transferred audio signals. Refer to the Peak Audio home page for more details: http://www.peakaudio.com/ ■ Bundles 2 Audio is transmitted over the CobraNet network in units known as “bundles.” These bundles are processed at the receiving end to reconstitute the original audio signals. In the case of the MY16-C a bundle can contain from 3 to 8 channels. Each bundle is identified by a number from 0 to 65,279, and audio transmission via the network becomes possible when the same bundle number is specified at both the transmitting and receiving devices. Bundles can be transmitted and received over the entire network as long as sufficient network resources are available. The system is designed so that each device can transmit and receive up to 8 bundles simultaneously, but the actual number of bundles that can be handled will depend on the capabilities of the equipment used. The MY16-C can be set to handle 2 transmit bundle numbers and 2 receive bundle numbers. The bundle numbers can be specified via the rotary switches on the MY16-C card itself, or via the device or software used by the device in which the card is installed. The procedure for setting the MY16-C bundle numbers is described in the "Controls & Functions" section on page 8. 4 MY16-C Owner’s Manual ■ Multicast Bundles and Unicast Bundles Two types of bundle can be used with CobraNet: “multicast” bundles and "unicast" bundles. Multicast bundles can be transmitted from a single device to all devices on the network, while unicast bundles are transferred from a single transmitting device to a single receiving device or a limited number of receiving devices. Unicast bundles are only sent to devices which have been set to the same bundle number as the transmitting device. Multicast bundles are sent to all devices on the network regardless of their settings, but only bundles with the specified bundle number(s) are processed. For this reason multicast bundles make heavy use of network resources and it is recommended that the maximum number of bundles be limited to 4 (32 channels). Unicast bundles should be employed when it is necessary to handle 5 or more bundles at a time. Different number ranges are used for multicast and unicast bundles: multicast bundles are numbered 1 through 255, while unicast bundles are numbered 256 through 65,279. Multicast Bundles Multicast bundles transmitted from device A are sent to all devices on the network (B through D in the example). CobraNet Device CobraNet Device Digital Audio Data D C Network B Unicast Bundles Unicast bundles are received only by devices set to receive the same bundle numbers as the transmit bundle number of the transmitting device A (device D in this example). A CobraNet Device CobraNet Device CobraNet Device CobraNet Device Digital Audio Data D C Network B CobraNet Device A CobraNet Device 3 MY16-C Owner’s Manual 5 ENGLISH MY16-C_E.book Page 5 Tuesday, April 13, 2004 7:32 PM MY16-C_E.book Page 6 Tuesday, April 13, 2004 7:32 PM n Digital signals and control data are transmitted and received by all conductor and performer devices on the CobraNet network. Performer (Receive) Performer (Receive) Sync (Word Clock) D C Network Conductors transmit the synchronization signal that is received and used by performers. Clock synchronization is necessary to transfer digital audio data to and from devices outside the CobraNet network. In this example device B on the CobraNet network sends the synchronization signal to external device E. B A Performer (Receive) Conductor (Transmit) E External Digital Device ■ CobraNet Cables and Hubs Category-5 metal cables can be used for runs of up to 100 meters, while multimode optical fiber cables can be used for runs of up to 2 kilometers. “Cross” and “straight” Ethernet cables are available. “Cross” cables should be used for direct connection between two devices. Hubs and "straight" cables are required to connect 3 or more devices. Ethernet hubs are available in “repeater” and "switching" configurations. Switching hubs are recommended for use on CobraNet networks. The use of repeater hubs can result in excessive network traffic, thus reducing network efficiency. It is best to use a repeater hub that has been tested and certified by Peak Audio. A list is available at http://www.peakaudio.com/cobranet/tested_ethernet.html. 4 ENGLISH ■ Conductor and Performers On any CobraNet network one device generates a timing signal that all other devices receive and are synchronized to. The device that generates the synchronization signal is known as the “conductor,” while all other devices are “performers.” The conductor for the network is automatically assigned and need not be specified by the operator. When an MY16-C is assigned to be the conductor for the network, the LED indicator to the right of the connector that is connected to the network will light orange. If the conductor fails for some reason, conductor status is automatically switched to another device on the network. Since the conductor transmits the synchronization signal to the performers via the network cable, no separate word clock cables are required and the total number of cables used by the system is kept to a minimum. Digital audio devices that are not connected to the network, however, will need to receive a word clock signal from a device on the network in order to achieve synchronization. 6 MY16-C Owner’s Manual ENGLISH MY16-C_E.book Page 7 Tuesday, April 13, 2004 7:32 PM The MY16-C System The internal signal flow of the MY16-C is shown in the illustration below. 16 audio inputs and 16 audio outputs are available, and for this example channels 1 ~ 8 are bundle 1, and channels 9 ~ 16 are bundle 2. CobraNet Device CobraNet Connector1 MY16-C Receive Bundle1 Transmit Bundle2 CobraNet Audio Receive Bundle2 Transmit Bundle2 Audio Convert Optional I/O Slot CobraNet cable CobraNet audio signal Audio signal outside CobraNet network Control Data DME64N/24N etc n Depending on the setup, less than 8 channels may be handled by each bundle. The relationship between the settings and the number of channels than can be handled by each bundle is shown below. Settings vs. Number of Channels per Bundle Channels per Bundle Latency 5.33 ms 16 bit, 48kHz 20 bit, 48kHz 24 bit, 48kHz 16 bit, 96kHz 20 bit, 96kHz 24 bit, 96kHz 8 8 7 4*1 4*1 3*1 4*1 4*1 4*1 4*1 2.66 ms 8 8 8 4*1 1.33 ms 8 8 8 4*1 *1 Number of channels when 48-kHz channel pairs are combined to create single 96-kHz channels. Channels per Bundle & Usable No. of Channels Channels per Bundle Usable No. of Channels 5 Bundle1 Bundle2 8 1-8 9-16 7 1-7 9-15 4 1,3,5,7 9,11,13,15 3 1,3,5 9,11,13 MY16-C Owner’s Manual 7 MY16-C_E.book Page 8 Tuesday, April 13, 2004 7:32 PM ■ Panel Connectors and Switches 3 Gr-LINK Rd-FAULT 4 3 1 PRIMARY 4 Gr-IN USE Or-CONDUCT 2 SECONDARY BUNDLE ASSIGNMENT 4 56 23 4 56 23 4 56 23 4 56 23 4 56 4 56 F0 1 F0 1 4 56 4 56 23 F0 1 23 F0 1 23 F0 1 23 F0 1 IN 1 F0 1 CobraNet INTERFACE CARD MODEL MY16-C 6 789 CD AB E IN 2 7 89 CD AB E 7 89 CD AB E OUT 1 7 89 CD AB E OUT 2 7 89 CD AB E 7 89 CD AB E 7 89 CD AB E CD AB E 7 89 F0 1 MADE IN JAPAN 5 1 [PRIMARY] and 2 [SECONDARY] Connectors These are 100Base-T Ethernet connectors. The MY16-C provides two Ethernet connectors to allow construction of redundancy networks employing dual (primary and secondary) circuits. The [PRIMARY] connector is for connection to the main circuit, while the [SECONDARY] connector is for connection to the backup circuit. If a failure occurs on the PRIMARY circuit (e.g. a cable failure, accidental disconnection, switching hub failure, etc.) the SECONDARY circuit will automatically take over. Basic redundancy network setup is described on page 17. Use STP (Shielded Twisted Pair) cables to protect against electromagnetic interference. 3 [LINK/FAULT] Indicators These are the LED indicators to the left of the [PRIMARY] and [SECONDARY] connectors. These indicators will light when a network cable is connected to the corresponding connector. The indicator for each connector will light green when a network cable is properly connected, and will flash while data is being properly transferred via the corresponding connector. If an error occurs on the connected network, the appropriate indicator will light or flash red. If an indicator lights or flashes red, try disconnecting it from the corresponding Ethernet connector. The indicator will go out if a cable, hub, or other device connected to the network has failed. If the indicator remains lit or flashing even after the cable is disconnected, there may be a fault in the MY16-C card itself. In this case please refer the problem to qualified Yamaha service personnel. 4 [IN USE/CONDUCT] Indicators These are the indicators to the right of the [PRIMARY] and [SECONDARY] connectors. These indicators will light when power has been properly applied to the MY16-C card. These indicators normally light green, but will light orange when the MY16-C is operating as the network conductor. 6 ENGLISH Controls & Functions 8 MY16-C Owner’s Manual 5 BUNDLE ASSIGNMENT [IN1] and [IN2] Rotary Switches These switches set the receive bundle number for audio signals to be received over the CobraNet network. The [IN1] switches specify the receive bundle 1 number, and the [IN2] switches specify the receive bundle 2 number. Two rotary switches are used to specify each number. See "Bundle Number Setting Procedure" on page 15 for details. 6 BUNDLE ASSIGNMENT [OUT1] and [OUT2] Rotary Switches These switches set the transmit bundle number for audio signals to be transmitted over the CobraNet network. The [OUT1] switches specify the transmit bundle 1 number, and the [OUT2] switches specify the transmit bundle 2 number. Two rotary switches are used to specify each number. See "Bundle Number Setting Procedure" on page 15 for details. ■ Circuit-board Switches RX 7 TX 8 7 SERIAL ASSIGNMENT [RX] Rotary Switch Sets the receive channel for the CobraNet serial control signal from channel 1 through channel 15. The control signals are received from a device that has been set to the matching transmit-channel number. No serial control reception occurs if this switch is set to “0”. 8 SERIAL ASSIGNMENT [TX] Rotary Switch Sets the transmit channel for the CobraNet serial control signal from channel 1 through channel 15. The control signals are sent to devices that have been set to the matching receive-channel number. No serial control transmission occurs if this switch is set to “0”. When adjusting rotary switches please use a screwdriver with a blade that matches the switch groove. Attempting to use a screwdriver that is too large or too small can damage the switch. 7 MY16-C Owner’s Manual 9 ENGLISH MY16-C_E.book Page 9 Tuesday, April 13, 2004 7:32 PM MY16-C_E.book Page 10 Tuesday, April 13, 2004 7:32 PM 1 2 3 4 5 6 7 8 O N No. Function 1 BIT 2 Fs 3 LATENCY 1 4 LATENCY 2 5 CLOCK 1 6 CLOCK 2 7 RESERVED 1 8 RESERVED 2 n The RESERVED 1 and RESERVED 2 switches are reserved for functions to be implemented in the future. Leave both of these switches OFF. ■ Audio Bits (BIT) DIP switch 1 sets the audio bit depth. BIT Audio Bit Depth OFF 20 bit ON 24 bit ■ Clock Frequency (Fs) DIP switch 2 sets the audio clock frequency or sample rate. Fs Clock Frequency OFF 48 kHz ON 96 kHz n Set all other MY16-C cards installed in the same device to the same clock frequency. Set all CobraNet devices receiving and transmitting the same audio signals to the same clock frequency. 8 ENGLISH ■ DIP Switches The DIP switches on the MY16-C circuit board can be used to set audio resolution, latency, the clock synchronization mode, and clock frequency. All dip switches are OFF when the MY16-C is initially shipped. 10 MY16-C Owner’s Manual MY16-C_E.book Page 11 Tuesday, April 13, 2004 7:32 PM LATENCY 1 LATENCY 2 OFF OFF 5.33 ms OFF ON 2.67 ms ON OFF 1.33 ms ON ON Reserved ENGLISH LATENCY 1/2 DIP switches 3 and 4 (LATENCY 1 and LATENCY 2) set the audio latency. LATENCY n Set all CobraNet devices receiving and transmitting audio signals to the same latency. Clock Synchronization Mode (CLOCK 1/2) DIP switches 5 and 6 (CLOCK 1 and CLOCK 2) specify the clock synchronization mode to be used. See "Clock Synchronization Modes" on page 12 for more information. CLOCK 1 CLOCK 2 Clock Synchronization Mode OFF OFF Network synchronization OFF ON Host synchronization 1 ON OFF Host synchronization 2 ON ON Reserved 9 MY16-C Owner’s Manual 11 MY16-C_E.book Page 12 Tuesday, April 13, 2004 7:32 PM ENGLISH Clock Synchronization Modes The MY16-C provides a selection of three clock synchronization modes: Network synchronization, host synchronization 1, and host synchronization 2. Network Synchronization In this mode the MY16-C receives synchronization from the network. This is the normal synchronization mode. When the MY16-C is set to network synchronization, make sure that the audio device in which the MY16-C is installed is synchronized to the MY16-C clock. An example of network synchronization N : Network Synchronization MY16-C N Clock Non-network Device DME64N/24N, PM5D etc Network MY16-C MY16-C N DME64N/24N, PM5D etc N DME64N/24N, PM5D etc Host Synchronization 1 Use this mode if the device in which the MY16-C is installed is synchronized to a clock signal other than the CobraNet clock. When the Host Synchronization 1 mode is selected the MY16-C receives synchronization from the device in which it is installed (the "host"), and that clock signal is then supplied to the network. When the host Synchronization 1 mode is selected, make sure that the host device is set to feed a clock signal to the MY16-C card. n When using the Host Synchronization 1 mode make sure that the frequency of the clock signal supplied to the MY16-C is within ±50 ppm of 48 kHz or 96 kHz. Proper operation is not guaranteed with clock frequencies outside this range, and problems with noise or instability may be encountered. Examples of host synchronization 1 N : Network Synchronization H1 : Host Synchronization 1 a. MY16-C Clock H1 Non-network Device DME64N/24N, PM5D etc Network MY16-C N N DME64N/24N, PM5D etc 10 DME64N/24N, PM5D etc MY16-C 12 MY16-C Owner’s Manual b. MY16-C ENGLISH MY16-C_E.book Page 13 Tuesday, April 13, 2004 7:32 PM N : Network Synchronization H1 : Host Synchronization 1 N DME64N/24N, PM5D etc Network MY16-C MY16-C H1 H1 DME64N/24N, PM5D etc DME64N/24N, PM5D etc Clock Non-network Device Host Synchronization 2 Use this mode if the MY16-C card is to be synchronized to the clock signal from another MY16-C card installed in the same device. When more than one MY16-C cards are installed in the same device and synchronization is to be received from the CobraNet network, set one of the installed MY16-C cards to Network Synchronization, and the other card(s) in the same device to Host Synchronization 2. An example of host synchronization 2 N : Network Synchronization H2 : Host Synchronization 2 MY16-C N H2 H2 PM5D etc Network MY16-C N DME64N/24N, PM5D etc MY16-C H2 N DME64N/24N, PM5D etc 11 MY16-C Owner’s Manual 13 MY16-C_E.book Page 14 Tuesday, April 13, 2004 7:32 PM An example of all three synchronization modes used simultaneously. a. MY16-C N N : Network Synchronization H1 : Host Synchronization 1 H2 : Host Synchronization 2 H2 DME64N/24N, PM5D etc Network MY16-C MY16-C N H1 Clock Non-network Device DME64N/24N, PM5D etc DME64N/24N, PM5D etc b. MY16-C N N : Network Synchronization H1 : Host Synchronization 1 H2 : Host Synchronization 2 H2 DME64N/24N, PM5D etc Network MY16-C H1 DME64N/24N, PM5D etc H1 MY16-C H1 H1 DME64N/24N, PM5D etc Clock Non-network Device 12 ENGLISH In some cases, all three synchronization modes are combined. 14 MY16-C Owner’s Manual ENGLISH MY16-C_E.book Page 15 Tuesday, April 13, 2004 7:32 PM MY16-C Card Installation Procedure Carefully read the precautions on page 2 before installing the MY16-C. 1 Set the MY16-C circuit-board DIP switches and rotary switches as required for your application. Refer to "Circuit-board Switches" on page 9 for details about the switch settings. These switches cannot be accessed while the MY16-C card is installed in its host device. If you need to change the circuit board switch settings, turn power to the host device off, remove the MY16C card, change the settings as required, then re-install the MY16-C card in the device. 2 Install the MY16-C card in an appropriate card slot on the host device. Refer to the operation manual of the host device for details. Make sure that the host device’s power is turned off before installing the card. Be sure to disconnect the power cable of the main unit before installing the MY16-C. The screws function as part of the ground line, and should be tightened securely. 3 Connect the MY16-C card to another device on the CobraNet network using category-5 cable. Refer to the "Connection Examples" on page 16. 4 Set the bundle numbers as required. Bundle Number Setting Procedure Using the hexadecimal system, the left rotary switch sets the most significant bits of the number while the right switch sets the least significant bits. In short, the value of the left switch multiplied by 16 is added to the value of the right switch to produce 256 different values. The relationship between the switch settings and bundle numbers is shown in the chart below. For example, if the left switch is set to "0" and the right switch is set to "A," the corresponding bundle number would be "10" in decimal. If the left switch is set to "1" and the right switch to "5," the bundle number would be 277 decimal. Example: Bundle No.10 4 56 4 56 23 F0 1 23 7 89 F0 1 0 CD AB E CD AB E 7 89 A Example: Bundle No.277 4 56 4 56 23 F0 1 23 7 89 5 CD AB E F0 1 1 CD AB E 7 89 Switch setting (Hexadecimal) Bundle number (Decimal) 00 No transfer 01 1 02 2 . . . . . . 0F 15 10 272 11 273 . . . . . . FE 510 FF Ignored When adjusting rotary switches please use a screwdriver with a blade that matches the switch groove. Attempting to use a screwdriver that is too large or too small can damage the switch. 13 n In some cases it is possible to set the bundle numbers from the device in which the MY16C card is installed, or via software running on the host device. In such cases the device’s bundle settings take priority over the card’s rotary switches. It may also be possible to set a wider range of bundle numbers than is available via the rotary switches. MY16-C Owner’s Manual 15 MY16-C_E.book Page 16 Tuesday, April 13, 2004 7:32 PM Connecting Two Devices Cross Cable Audio signal and control data MY16-C MY16-C 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 48kHz 2 3 4 2 3 4 5 6 7 8 5 6 7 8 PEAK IN SIGNAL 1 44.1kHz PEAK SCENE NUMBER SIGNAL OUT DME24N DME64N Connecting via a Hub Straight Cable 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 48kHz 2 3 4 2 3 4 5 6 7 8 5 6 7 8 PEAK IN SIGNAL 1 44.1kHz PEAK SCENE NUMBER OUT SIGNAL MY16-C DME24N DME64N MY16-C DME64N MY16-C Switching Hub Audio signal and control data MY16-C MY16-C MY16-C 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 48kHz 2 3 4 5 6 7 8 5 6 7 8 PEAK IN SIGNAL 1 2 3 4 44.1kHz PEAK SCENE NUMBER SIGNAL OUT DME24N DME64N DME64N Connecting to a Mixer Straight Cable YAMAHA Digital Console MY16-C Switching Hub MY16-C Audio signal and control data MY16-C MY16-C MY16-C 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 48kHz 2 3 4 2 3 4 5 6 7 8 5 6 7 8 PEAK IN SIGNAL 1 44.1kHz PEAK SCENE NUMBER SIGNAL OUT DME24N 16 MY16-C Owner’s Manual DME64N DME64N 14 ENGLISH Connection Examples Connecting to Other CobraNet Devices Straight Cable MY16-C DME64N ACU16-C Audio signal and control data Audio signal only Switching Hub Audio signal and control data Audio signal only NETWORK HUB AND BRIDGE LINK LOCK MY16-C 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 2 3 4 5 6 7 8 5 6 7 8 CONDUCT ERROR 88 NHB32-C PEAK 48kHz IN SIGNAL 1 2 3 4 44.1kHz PEAK SCENE NUMBER SIGNAL OUT DME24N n Not compatible with ACU16-C or NHB32-C control signals. CobraNet Redundancy Network n Redundancy Networks Redundancy networks employ dual (primary and secondary) circuits. Communication usually occurs over the primary circuit, but if a failure occurs on the primary circuit – cable failure, accidental disconnection, switch failure, etc. – the secondary circuit will automatically take over. Redundancy networks offer significantly higher reliability compared to single-circuit systems. 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 48kHz 2 3 4 2 3 4 5 6 7 8 5 6 7 8 1 PEAK IN SIGNAL 1 EXT. CLOCK NETWORK 96kHz MID 88.2kHz MASTER 48kHz 44.1kHz 2 3 4 2 3 4 5 6 7 8 5 6 7 8 Straight Cable (Primary CobraNet) PEAK IN SIGNAL 1 44.1kHz PEAK PEAK SCENE NUMBER SIGNAL DME24N SCENE NUMBER OUT SIGNAL MY16-C DME24N Switching Hub A MY16-C Straight Cable (Secondary CobraNet) Switching Hub B MY16-C DME64N OUT MY16-C DME64N 15 MY16-C Owner’s Manual 17 ENGLISH MY16-C_E.book Page 17 Tuesday, April 13, 2004 7:32 PM specifications.fm Page 18 Thursday, April 15, 2004 2:43 PM ENGLISH Specifications Digital Input/Output Characteristics <fs=48kHz> Terminal Format Latency DEUTSCH Data Length Audio 20bit 16ch Input / 16ch Output 24bit 14ch Input / 14ch Output 20bit 16ch Input / 16ch Output 24bit 16ch Input / 16ch Output 20bit 16ch Input / 16ch Output 24bit 16ch Input / 16ch Output Connector 5.33ms CobraNet Primary/Secondary CobraNet 2.67ms RJ45 1.33ms FRANÇAIS Min. 47.9976 Sampling Frequency Range Typ. 48 Max. 48.0024 <fs=96kHz> Terminal Format Latency Audio 20bit 8ch Input / 8ch Output 24bit 6ch Input / 6ch Output 20bit 8ch Input / 8ch Output 24bit 8ch Input / 8ch Output 20bit 8ch Input / 8ch Output 24bit 8ch Input / 8ch Output Connector 5.33ms CobraNet Primary/Secondary CobraNet 2.67ms RJ45 1.33ms Min. 95.9952 Sampling Frequency Range Typ. 96 Max. 96.0048 General Specifications Dimensions (mm) 120 x 40 x 200 (W x H x D) Net Weight (kg) 0.6 Temperature Range (°C) 10~35 (Operating Temperature Range) -20~60 (Storage Temperature Range) Accessories Owner’s Manual CobraNet Ports (100Base-TX Ethernet, RJ-45) Pin 1 2 3 4 5 6 7 8 Connection TxD+ TxD– RxD+ Unused Unused RxD– Unused Unused 64 ESPAÑOL Data Length 18 MY16-C Owner’s Manual ENGLISH specifications.fm Page 19 Monday, April 19, 2004 8:32 PM Straight/Cross Cable Wiring Details Cross Cables Straight Cables DEUTSCH Pins 1 —— 3 2 —— 6 3 —— 1 4 —— 4 5 —— 5 6 —— 2 7 —— 7 8 —— 8 Pins 1 —— 1 2 —— 2 3 —— 3 4 —— 4 5 —— 5 6 —— 6 7 —— 7 8 —— 8 ESPAÑOL 200 FRANÇAIS Dimensions 37 40 120 Unit: mm * Specifications and descriptions in this owner's manual are for information purposes only. Yamaha Corp. reserves the right to change or modify products or specifications at any time without prior notice. Since specifications, equipment or options may not be the same in every locale, please check with your Yamaha dealer. * Die technischen Daten und Beschreibungen in dieser Bedienungsanleitung dienen nur der Information. Yamaha Corp. behält sich das Recht vor, Produkte oder deren technische Daten jederzeit ohne vorherige Ankündigung zu verändern oder zu modifizieren. Da die technischen Daten, das Gerät selbst oder Sonderzubehör nicht in jedem Land gleich sind, setzen Sie sich im Zweifel bitte mit Ihrem Yamaha-Händler in Verbindung. * Les caractéristiques techniques et les descriptions du mode d'emploi ne sont données que pour information. Yamaha Corp. se réserve le droit de changer ou modifier les produits et leurs caractéristiques techniques à tout moment sans aucun avis. Du fait que les caractéristiques techniques, les équipements et les options peuvent différer d’un pays à l'autre, adressez-vous au distributeur Yamaha le plus proche. * Las especificaciones y descripciones de este manual del propietario tienen sólo el propósito de servir como información. Yamaha Corp. se reserva el derecho a efectuar cambios o modificaciones en los productos o especificaciones en cualquier momento sin previo aviso. Puesto que las especificaciones, equipos u opciones pueden no ser las mismas en todos los mercados, solicite información a su distribuidor Yamaha. 65 MY16-C Owner’s Manual 19 Yamaha Manual Library http://www2.yamaha.co.jp/manual/english/ • This document is printed on chlorine free (ECF) paper with soy ink. • Auf Umweltpapier mit Sojatinte gedruckt. • Ce document a été imprimé sur du papier non blanchi au chlore avec de l'encre d'huile de soja. • Este documento se ha impreso en papel sin cloro alguno, con tinta de soja. U.R.G., Pro Audio & Digital Musical Instrument Division, Yamaha Corporation © 2004 Yamaha Corporation WC95460 404MWCP3.2-01A0 Printed in JAPAN
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Yamaha MY16-C El manual del propietario

Tipo
El manual del propietario
Este manual también es adecuado para