Real Flame CT0003LP-GLS El manual del propietario

Tipo
El manual del propietario
If the information in this manual
is not followed exactly, a fi re or
explosion may result causing
property damage personal injury
or loss of life.
Improper Installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage.
Read the installation, operation
and maintenance instructions
thoroughly before installing or
servicing this equipment.
!
!
IMPORTANT
WARNING
SAVE THESE INSTRUCTIONS
!
DANGER
If you smell gas:
C SU
For Technical Support Please Contact Real Flame® At: 1-800-654-1704
CT0003LP Ledgestone Fire Table NG Conversion Kit
1. Shut o gas to the appliance
2. Extinguish any open flame
3. If odor continues, keep away from the appliance and
immediately call your gas supplier or fire department.
PARTS LIST 00023109S
1
2
3
NA
TURAL GA
S C
ONVERSION KIT
NOTE
This conversion kit is for changing a Liquefied Petroleum (LP) fire table into a Natural Gas
fire table.
!
This conversion kit shall be installed by a qualified service agency in accordance with
Real Flame’s instructions and all applicable codes and requirements of the Authority
Having Jurisdiction. If the information in these instructions is not followed exactly, a fire,
explosion or production of carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the operation of
the converted appliance is checked as specified in the manufacturer’s instructions
supplied with this kit.
WARNING
!
Natural Gas Hose and Quick Disconnect
NG Orifice Spud 4.05mm
Primary Air Mixer Sleeve
4
4
5
Conversion Plaque
Cable Kit
3
1
2
5
1
CT0003 Ledgestone
Conversion
65,000 BTU/Hr. (19.05 kW)
NATURAL GAS CONVERSION
2
3.) Disconnect LP hose from valve.
4.) Disconnect bellows (CSST) from burner base.
Bellows
(CSST)
3
NATURAL GAS CONVERSION
5.) Remove the existing LP orifice spud.
LP Orifice Spud
4
NATURAL GAS CONVERSION
6.) Locate the new NG orifice spud, verify it is the correct number.
The number 4.05mm should be on the end of the orifice spud.
7.) Slip sleeve over primary air opening. See fig. 1
Next, screw the new NG orifice spud into the burner base. See fig. 2
Sleeve
Primary Air
Opening
NG Orifice
Spud
1
2
4.05mm
5
NATURAL GAS CONVERSION
9.) Attach NG hose to the input side of the valve.
Bellows
(CSST)
8.) Re-attach bellows (CSST) to new spud.
6
10.) Attach quick disconnect to gas supply.
NATURAL GAS CONVERSION
House Natural Gas Piping
Quick Disconnect Socket
NG Gas Hose
To Fire Table
Shut-o Valve
11.) After installing the conversion kit, verify the location of the
Thermocouple and Igniter Pin using the illustration below.
Installing at Altitude
For installations at elevations above 2000 ft. contact your local dealer or gas
supplier before installing as input rating should be reduced approximately 4%
for each 1000 ft. above sea level. Refer to the National Fuel Gas Code.
Contact the Real Flame for more information at 1-800-654-1704
12.) Note to installation technicians. Verify the manifold pressure by using a
3/8” flared T-junction at the location marked by the arrow below. Then using
a digital manometer verify that the pressure before the orifice is 7” W.C. Also
verify that the orifice spud has the 4.05mm marked. This will allow you to verify
that the input rating of the appliance is correct.
NATURAL GAS CONVERSION
7
To Manometer
5mm
Thermocouple
Igniter Pin
Cut Cable
Re-attach both plaques
NOTE: The proper manifold pressure for this converted appliance is 7” water column.
NOTE: The maximum inlet gas pressure for this unit is 10.5 in wc (2.61 kPa)
The minimum inlet gas pressure for this unit is 3.5 in wc (0.87 kPa)
NATURAL GAS CONVERSION
WARNING Before using this outdoor fire table, make sure you have read, understand and
are following all information provided in the important Safety Information section of this
manual. Failure to follow those instructions can cause death, serious injury or property damage.
!
Check for leaks at these locations
13. CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dishwashing soap
with 3 parts water in a spray bottle.
Make sure the control knob is “OFF. Then, turn the Natural Gas on
at its source.
Spray leak solution on the valve connections, paying particular
attention to the areas indicated by the arrows.
If any bubbles appear turn the Natural Gas o˜ a t its source, recon-
nect and re-test. If you continue to see bubbles after several
attempts, disconnect the Natural Gas Source and Contact Real
Flame
® at 1-800-654-1704 for assistance.
If no bubbles appear after one minute turn the gas
source “OFF”, wipe away solution and proceed.
8
14.) Cut the existing French Plaque o of the control panel using wire cutters. Re-attach the
French plaque and NG conversion plaque included with this kit to the fire table using
the included cable kit.
15.) Lighting
Lighting Instructions
LIGHT
LOW
Control Knob
PUSH
IN
9
1. Read and understand all operating instructions before lighting.
2. Burner control knob must be in the OFF position.
3. Ensure that gas supply is connected and open
4. Push and hold igniter button to create sparks.
5. While holding the igniter button with one hand, use your other
hand to push and turn the control knob to the LIGHT position
to light the burner.
6. Keep Burner Control Knob pressed in for 15-30 seconds
after ignition.
7. If ignition does not occur in 30 seconds, turn control knob to
minutes until gas has cleared and repeat lighting procedure.
8. After lighting, rotate the Burner Control Knob counter
clockwise to LOW setting. Observe flame, make sure all
burner ports are lit.
9. Adjust the flame to the desired height with the
control knob.
1. Wearing heat resistant gloves, position the burning
long match or burning butane lighter near the side of
the burner. DO NOT lean over the fire table while
lighting.
2. Turn control knob counterclockwise to LIGHT.
3. Remove long match/long butane lighter.
4. After lighting, rotate the Burner Control Knob counter
clockwise to LOW setting. Observe flame, make sure
all burner ports are lit.
5. Adjust the flame to the desired height with the
control knob.
by step instructions. Failure to do so could result in severe injury.
If burner flame goes out during operation, immediately turn the control knob OFF and let the
gas clear a minimum of 5 minutes before attempting to re-light the fire table.
Using the Igniter
!
!
WARNING
WARNING
Using a Long Match or Lighter
8-13”
20.3 - 30.5 cm
When using this method to light your fire table, use heat resistant gloves and follow the step
NOTES AND TECHNICAL SUPPORT
Type of Gas / Type de gaz: NG/Natural Gas
Normal Hourly Input/Entrée horaire normal:
65,000 BTU/Hr. (19.05 kW)
Manifold Pressure/Pression d'admission:
7.0” water column (1.74 kPa)
The minimum inlet pressure for this fire table is:
3.5” water column (0.87 kPa)
The maximum inlet pressure for this fire table is:
10.5” water column (2.61 kPa)
®
C SU
This appliance was converted on _________________
(DD/MM/YY)
to Natural Gas with Kit No._______________________
(Found on Box)
by___________________________________________,
(Name and address of organization making this conversion)
which accepts the responsibility that this conversion has
been properly made.
For additional technical support call: 1-800-654-1704
Cet appareil a été converti le
en gaz naturel avec le kit no.
par
NOTES: ______________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
10
l’information fournie dans ce
manuel n’est pas suivi à la lettre,
un incendie ou une explosion
entr nant des dommages
corporels ou la perte de vie.
Une mauvaise installation,
d’ajustement, modification,
service ou d’entretien peut
causer des blessures ou des
dommages matériels.
Lisez l’installation, l’opération et
des instructions de maintien à
fond avant stallation ou
entretien de cet équipement.
!
!
IMPORTANT
!
DANGER
immédiatement votre fournisseur de gaz ou le service des incendies.
USC
our le support technique veuillez contacter ame à
AVERTISSEMENT
CONSERVEZ CES INSTRUCTIONS
Kit de conversion NG de CT0003LP Ledgestone
de la table-foyer rectangular
LISTE DES PIECES
00023109S
1
2
3
KIT DE CONVERSION DU GAZ NATUREL
NOTE
Ce kit de conversion est pour changer un table de feu de Pétrole Liquéfié (LP) dans une
table de feu de Gaz naturel.
!
Ce kit de conversion doit être installé par un service d’entretien qualifié conformément
aux instructions du Real Flame et tous les codes applicables et les exigences de
l’autorité ayant la Juridiction. Si l’information dans ces instructions n’est pas suivi
exactement, un incendie, une explosion ou la production de monoxyde de carbone peut
causer des dommages matériels, des blessures corporelles ou la pertes de vie. Le
service d’entretien qualifié est responsable de l’installation appropriée de ce kit.
L’installation n’est pas bon et complet jusqu’à la fonctionnement de l’appareil converti
est contrôlé comme spécifié dans les instructions du fabricant fournies avec ce kit.
Tuyau de gaz naturel et déconnexion rapide
Patate d’orifice NG 4.05mm
Gaine de mixage d’air principal
4
4
5
Plaque de Conversion
Kit de câble
3
1
2
5
!
AVERTISSEMENT
che miné e
For technical support call: 1-800-654-1704
Pour d'assistance technique appelez : 1-800-654-1704
Type of Gas / Type de gaz: NG/Natural Gas
Normal Hourly Input/Ente horaire normal:
Manifold Pressure/Pression dadmission:
7.0" water column (1.74 kPa) / 7.0'' Colonne d'eau (1.74 kPa)
The minimum inlet pressure for thisre table is: /
La pression d'admission minimale pour cette table de feu est :
3.5" water column (0.87 kPa) / 3.5'' Colonne d'eau (0.87 kPa)
The maximum inlet pressure for thisre table is:
10.5" water column (2.61 kPa) / 10.5'' Colonne d'eau (2.61 kPa)
(Found on Box / Trouvé sur la Boîte)
(Name and address of organization making this conversion /
Nom et adresse d'organisation qui fait cette conversion)
1
CT000LP Ledgestone
Conversion
65,000 BTU/Hr. (19.05kW)
CONVERSION DU GAZ NATUREL
2
4.)Débrancher le souet (CSST) de la base du brûleur.
Souet
3.) Débrancher le souet (CSST) de la base de brûleur.
3
CONVERSION DU GAZ NATUREL
le patate d’orifice LP
5.) Retirez le patate d’orifice LP.
4
CONVERSION DU GAZ NATUREL
4.05mm
Gaine
L’ouverture
d’air principal
Patate
d’orifice NG
6.) Trouvez le nouveau patate d’orifice NG, vérifier qu’il n’est le bon
numéro. Le numéro 4.05mm devrait être sur l’extrémité d’orifice de patate.
7.) Glissez le gaine sur l’ouverture aérienne principale voir fig. 1
Ensuite, vissez la nouvelle patate d’orifice NG dans la base de brûleur.
Voir fig. 2
1
2
5
CONVERSION DU GAZ NATUREL
8.) Rattachez les souets (CSST) à la nouvelle patate.
Souets
(CSST)
9.) Attachez le tuyau NG au côté d’entrée de la soupape.
6
CONVERSION DU GAZ NATUREL
Tuyauterie de Gaz naturel de Maison
Soupape d'arrêt
Prise de déconnexion rapide
Tuyau de Gaz NG
Au Table de Feu
10.) Attachez le déconnexion rapide à l’approvisionnement en gaz.
Installation à Altitude
CONVERSION DU GAZ NATUREL
7
5mm
Thermocouple
Igniter
Au manomètre
Pour les installations à une altitude supérieure à 2000 pieds contactez votre
revendeur local ou fournisseur de gaz avant l’installation comme l’évaluation
d’entrée devrait être réduite d’environ 4% pour chaque 1000 pieds au-dessus
du niveau de la mer. Référez-vous au Code de Gaz combustible national.
Contactez Real Flame® pour plus d’information au 1-800-654-1704.
12.) Avis aux techniciens d’installation. Vérifiez que la pression d’admission
en utilisant un 3/8” raccord en tévasée à l’emplacement marqué par la
flèche ci-dessous. Puis en utilisant un manomètre numérique vérifie que la
pression avant l’orifice est 7” W.C. Vérifiez aussi que la patate d’orifice a la
4.05mm marqué. Ceci vous permettra de vérifier que l’évaluation d’entrée
de l’appareil est correcte.
11.) Après l’installation du kit de conversion, vérifiez l’emplacement du
pilote, le thermocouple et l’épingle d’allumeur utilisant l’illustration
ci-dessous.
Coupez le câble
Rattachez les deux plaques
NOTE : La pression d’admission appropriée pour cet appareil conv
CONVERSION DU GAZ NATUREL
Vériÿez pour des fuites à ces emplacements
13.) VÉRIFICATION POUR LES FUITES
Faire une solution de contrôle d’étanchéité en mélangeant 1 partie
de savon à vaisselle avec 3 parties d'eau dans un vaporisateur.
Assurez-vous que le bouton de commande est « OFF ».
Puis, tournez le sur le gaz naturel à sa source.
!
AVERTISSEMENT
Avant d’utiliser cette table de feu extérieure, assurez-vous que vous avez lu,
comprenez et suivez toutes les informations fournies dans la section importante de l’information de Sécurité de
ce manuel. L’échec de suivre ces instructions peut causer la mort, la blessure grave ou des dommages mariels.
Mur
8
14.) Coupez l’existante plaque française du panneau de contrôle utilisant un coup-fil. Rattachez
la plaque française et la plaque de conversion NG incluse avec ce kit à la table.
Pulvériser la solution de fuite sur les connexions de valve,
en accordant une attention particulière aux endroits
indiqués par les èches.
Si des bulles apparaissent, tourner le gaz naturel à sa
source, rebrancher et tester à nouveau. Si vous continuez à
voir des bulles après plusieurs tentatives, débrancher la
source de gas naturel et contacter Real Flame® à
1-800-654-1704 pour l’aide.
Si aucune bulle n’apparaît après un minute, éteint
la source de gaz, essuyer la solution et continuez.
15.) Éclairage
Instructions d'allumage
Bouton de commande
POUSSEE
DANS
9
1.
Lisez et comprenez tout le mode d’emploi avant d’allumer.
2.
Le bouton de commande de brûleur doit être dans la pos
3.
Assurez que
provisionnement en gaz est connec et ouvert
4.
ser et maintenir le bouton mage pour créer des étincelles.
5.
En tenant le bouton d’allumeur d’une main, utilisez votre autre
main pour pousser et tourner le bouton de commande vers la
6.
7.
8.
assurez-vous que tous les ports de brûleur sont allumés.
9.
Ajustez la flamme à la hauteur désirée avec le bouton de
commande.
1.
En portant des gants résistant à la chaleur, placez la longue
allumette brûlant ou briquet au
du
brûleur. Ne penchez pas la table de feu en allumant.
2.
Tournez le bouton de commande de tour en sens
3.
4.
Observez la flamme, assurez-vous que tous les ports
de brûleur sont allumés.
5.
Ajustez la flamme à la hauteur désirée avec le bouton
de commande.
Utilisation d’allumeur
Utilisation d’une longue Allumette ou briquet
!
AVERTISSEMENT
laamme de bleur s’éteint pendant lopération, tournez imdiatement le bouton de commande sur
O
et laisser le gaz dégage avec un minimu minutes avant d’essa er de rallumer la table de feu.
!
AVERTISSEMENT
En utilisant cette méthode pour allumer votre table de feu, utiliser des gants résistants à la chaleur
8-13”
20.3 - 30.5 cm
Type de gaz: GN/Gaz naturel
Entrée horaire normal:
65,000 BTU/Hr. (19.05 kW)
Pression d'admission:
7.0’’ Colonne d’au (1.74 kPa)
La pression d'admission minimale pour cette
table de feu est : 3.5’’ Colonne d’au (0.87 kPa)
La pression dadmission maximum pour cette
table de feu est : 10.5’’ Colonne d’au (2.61 kPa)
®
USC
Cet appareil a été converti _________________________
(DD/MM/YY)
en Gaz naturel avec No. de Kit ______________________
(Trouvé sur la Boîte)
par ____________________________________________,
(Nom et adresse d’organisation qui fait cette conversion)
qui accepte la responsabilité que cette conversion a été
.
NOTES: ______________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
Pour d’assistance technique supplémentaire appelez:
1-800-654-1704
10
Si la información contenida en este
manual no se observa estrictamente,
puede producirse un incendio o una
explosión, causando daños materiales,
lesiones personales o pérdida de vidas.
La instalación, ajuste, alteración,
servicio o mantenimiento en forma
incorrecta pueden causar lesiones o
daños a la propiedad.
Lea atentamente las instrucciones
de instalación, operación y
mantenimiento antes de instalar o
reparar este equipo.
!
!
IMPORTANTE
ADVERTENCIA
GUARDE ESTAS INSTRUCCIONES
!
PELIGRO
Si siente olor a gas
USC
Para obtener asistencia técnica, póngase en contacto
con Real Flame
®
llamando al: 1-800-654-1704
Kit de conversión a gas natural
de la tabla de fuego CT0003LP Ledgestone
1. Apague el artefacto
2. Extinguir cualquier llama abierta.
3. Si el olor continúa, manténgase alejado del artefacto y llame
inmediatamente a su proveedor de gas o al departamento de
bomberos.
LISTA DE PIEZAS
00023109S
1
2
3
KIT DE CONVERSIÓN DE GAS NATURAL
AVISO
Este kit de conversión es para convertir una tabla de fuego alimentada a petróleo licuado
(LP) en una tabla de fuego alimentada a gas natural.
!
Este kit de conversión debe ser instalado por una agencia de servicios calificada de acuerdo
con las instrucciones de Real Flame y todos los códigos y requisitos aplicables de la
Autoridad de Jurisdicción. Si la información contenida en estas instrucciones no se observa
estrictamente, puede producirse monóxido de carbono, incendio o explosión, causando
daños materiales, lesiones personales o pérdida de vidas. La agencia de servicio calificada
es responsable de la correcta instalación de este kit. La instalación no es considerada
correcta y completa hasta que el funcionamiento del artefacto convertido se compruebe
como se especifica en las instrucciones del fabricante suministradas con este kit.
!
ADVERTENCIA
Manguera de gas natural y desconexión rápida
4
4
5
Placa de conversión
Juego de cables
3
1
2
5
Intermediario de orificio de GN 4.05mm
Mezclador de aire primario
!
1
CT0003LP Ledgestone
Conversion
40,000 BTU/Hr. (11.72kW)
CONVERSIÓN DE GAS NATURAL
2
3.) Desconecte el fuelle (CSST) de la base del quemador.
4.) Desconecte el fuelle (CSST) de la base del quemador.
Fuelle
3
CONVERSIÓN DE GAS NATURAL
5.) Retire el intermediario de LP existente.
Intermediario de LP
CONVERSIÓN DE GAS NATURAL
7.) Deslice la manga sobre la abertura de aire primario. Ver fig 1.
Luego, atornille el nuevo intermediario de GN en la base del
quemador. Ver fig 2.
4
4.05mm
Manga
Apertura de
aire primario
Intermediario
de GN
6.) Localice el nuevo intermediario de GN, compruebe que sea el número
correcto. El número 4.05mm de be estar en el extremo del intermediario.
1
2
CONVERSIÓN DE GAS NATURAL
8.) Vuelva a conectar el fuelle (CSST) al nuevo intermediario.
Conecte la manguera de GN a la entrada de la válvula.
9.)
Fuelle
5
6
10.) Conecte la desconexión rápida al suministro de gas.
CONVERSN DE GAS NATURAL
Tubo de gas natural
Válvula de cierre
Conexión de la desconexión rápida
Manguera de gas GN
A la tabla
de fuego
11.) Después de instalar el kit de conversión, verifique la ubicación del
piloto, el termo acople y el pin encendedor utilizando la ilustración
a continuación.
Instalación en altitudes
CONVERSIÓN DE GAS NATURAL
7
5mm
Thermocouple
Igniter
Al manómetro
12.) Nota para técnicos de instalación. Verifique la presión del colector usando un
empalme en T de 3/8” en el lugar marcado por la flecha abajo. Luego, usando un
manómetro digital, verifique que la presión antes del orificio sea de 7” W.C. también
verifique que el intermediario tenga la marca 4.05mm esto le permitirá verificar que la
capacidad de entrada del artefacto es correcta.
Para instalaciones en altitudes superiores a 2000 pies, póngase en contacto con su
distribuidor local o proveedor de gas antes de la instalación, ya que la capacidad de
entrada debe reducirse aproximadamente un 4% por cada 1000 pies de altura sobre
el nivel del mar. Consulte el Código Nacional de Gas Combustible. Contacte a
Real Flame® para obtener más información al 1-800-654-1704
Cortar el cable
Colocar nuevamente las placas
AVISO: La presión de gas de entrada máxima para esta unidad es de 10.5 en wc (2.61 kPa)
La presión de gas de entrada mínima para esta unidad es de 3.5 en wc (0.87 kPa)
CONVERSIÓN DE GAS NATURAL
Compruebe si hay fugas en estas ubicaciones
13.) VERIFICAR FUGAS
Haga una solución de control de fugas mezclando 1 parte de detergente/
jabón lavavajillas con 3 partes de agua en una envase pulverizador.
Asegúrese de que la perilla de control esté en la posición "OFF".
A continuación, abra el suministro de gas natural.
Rocíe la solución de fugas en las conexiones de la válvula,
prestando especial atención a las áreas indicadas por las ˝echas.
Si no aparecen burbujas después de un minuto, cierre el
suministro de gas ("OFF"), limpie la solución y proceda.
ADVERTENCIA Antes de usar esta tabla de fuego de exteriores, asegúrese de haber leído,
comprendido y seguido toda la información proporcionada en la sección 'Información de
seguridad importante' de este manual. El incumplimiento de dichas instrucciones puede
ocasionar lesiones graves, daños a la propiedad o la muerte.
!
Pared
AVISO: La presión adecuada del colector para este artefacto convertido es de 7" de
columna de agua.
8
14.) Cortar la placa existente en francés del panel de control usando cortadores de
alambre. Vuelva a colocar la placa en francés y la placa de conversión a GN
incluidas con este kit en la tabla de fuego usando el juego de cables incluido.
Si aparecen burbujas, cierre el suministro de gas, vualva a
conectar y vuelva a probar. Si continúa viendo burbujas después
de varios intentos, cierre el suministro de gas natural y llame a
Real Flame® al 1-800-654-1704 para obtener ayuda.
15.) Encendido
Instrucciones de encendido
LIGHT
(ENCENDIDO)
LOW
Perilla de control
PUSH
IN
9
1.
Lea y comprenda todas las instrucciones de funcionamiento
antes de encender.
2.
La perilla de control del quemador debe estar en la posición OFF.
3.
Asegúrese de que el suministro de gas esté conectado y abierto
4.
Presione y mantenga presionado el botón del encendedor para
generar chispas.
5.
Mientras sostiene el botón del encendedor con una mano, use la
otra mano para empujar y girar la perilla de control a la posición
LIGHT (ENCENDIDO) para encender el quemador.
6.
Mantenga presionada la perilla de control del quemador durante
15-30 segundos después de encender.
7.
Si la ignición no ocurre en 30 segundos, gire la perilla de control a la
posicn OFF y cierre el suministro de gas, espere 5 minutos hasta que
se haya despejado el gas y repita el procedimiento de encendido.
8.
Después de encender, gire la perilla de control del quemador en
sentido anti horario hasta el ajuste LOW (BAJO). Observe la llama,
asegúrese de que todos los puertos del quemador estén encendidos.
9.
Ajuste la llama a la intensidad deseada mediante la perilla de control.
1.
Usando guantes resistentes al calor, coloque el
fósforo largo encendido o encendedor de gas butano
encendido próximo al lateral del quemador. NO SE
INCLINE sobre tabla de fuego mientras la enciende.
2.
Gire la perilla de control en sentido antihorario a
LIGHT (ENCENDIDO).
3.
Retire el fósforo largo / encendedor de gas butano.
4.
Después de encender, gire la perilla de control del
quemador en sentido anti horario hasta el ajuste LOW
(BAJO). Observe la llama, asegúrese de que todos los
puertos del quemador estén encendidos.
5.
Ajuste la llama a la intensidad deseada mediante la
perilla de control.
Uso del encendedor
Usando un fósforo largo o encendedor
(PRESIONAR)
(BAJO)
!
ADVERTENCIA
Si la llama del quemador se apaga durante el funcionamiento, gire inmediatamente la perilla de
control a la posición OFF deje que el gas desaparezca por lo menos durante 5 minutos antes de
intentar volver a encender la mesa de fuego.
!
ADVERTENCIA
Cuando use este método para encender su mesa de fuego, utilice guantes resistentes al
calor y siga las instrucciones paso a paso. No hacerlo, podría ser la causa de lesiones graves.
8-13”
20.3 - 30.5 cm
NOTAS Y SOPORTE CNICO
Tipo de gas: Gas natural / GN
Entrada normal por hora:
65,000 BTU/Hr. (19.05 kW)
Presión de admisión:
7.0” columna de agua (1.74 kPa)
La presión de entrada mínima para esta tabla de fuego es:
3.5” columna de agua (0.87 kPa)
La presión de entrada xima para esta tabla de fuego es:
10.5” columna de agua (2.61 kPa)
®
USC
Este artefacto fue convertido el: _________________
(DD/MM/AA)
A gas natural con el kit Nro._____________________
(Encontrado en la caja)
por__________________________________________,
(Nombre y dirección de la organización que realiza esta conversn)
Que acepta la responsabilidad de que esta conversn
fue hecha correctamente.
Para obtener soporte técnico adicional, llame a: 1-800-654-1704
NOTAS: ______________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
10

Transcripción de documentos

CT0003LP Ledgestone Fire Table NG Conversion Kit C ! WARNING US ! IMPORTANT SAVE THESE INSTRUCTIONS If you smell gas: ! DANGER 1. Shut off gas to the appliance 2. Extinguish any open flame 3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department. If the information in this manual is not followed exactly, a fire or explosion may result causing property damage personal injury or loss of life. Improper Installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment. For Technical Support Please Contact Real Flame® At: 1-800-654-1704 NATURAL GAS CONVERSION KIT ! WARNING ! NOTE This conversion kit shall be installed by a qualified service agency in accordance with Real Flame’s instructions and all applicable codes and requirements of the Authority Having Jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with this kit. This conversion kit is for changing a Liquefied Petroleum (LP) fire table into a Natural Gas fire table. PARTS LIST 00023109S 1 Natural Gas Hose and Quick Disconnect 4 Conversion Plaque 2 NG Orifice Spud 4.05mm 5 Cable Kit 3 Primary Air Mixer Sleeve 5 1 4 CT0003 Ledgestone Conversion 2 65,000 BTU/Hr. (19.05 kW) 3 1 NATURAL GAS CONVERSION 3.) Disconnect LP hose from valve. 4.) Disconnect bellows (CSST) from burner base. Bellows (CSST) 2 NATURAL GAS CONVERSION 5.) Remove the existing LP orifice spud. LP Orifice Spud 3 NATURAL GAS CONVERSION 6.) Locate the new NG orifice spud, verify it is the correct number. The number 4.05mm should be on the end of the orifice spud. 4.05mm 7.) Slip sleeve over primary air opening. See fig. 1 Next, screw the new NG orifice spud into the burner base. See fig. 2 1 Primary Air Opening 2 Sleeve 4 NG Orifice Spud NATURAL GAS CONVERSION 8.) Re-attach bellows (CSST) to new spud. Bellows (CSST) 9.) Attach NG hose to the input side of the valve. 5 NATURAL GAS CONVERSION 10.) Attach quick disconnect to gas supply. House Natural Gas Piping Shut-off Valve Quick Disconnect Socket NG Gas Hose To Fire Table 6 NATURAL GAS CONVERSION 11.) After installing the conversion kit, verify the location of the Thermocouple and Igniter Pin using the illustration below. Thermocouple 5mm Igniter Pin 12.) Note to installation technicians. Verify the manifold pressure by using a 3/8” flared T-junction at the location marked by the arrow below. Then using a digital manometer verify that the pressure before the orifice is 7” W.C. Also verify that the orifice spud has the 4.05mm marked. This will allow you to verify that the input rating of the appliance is correct. To Manometer Installing at Altitude For installations at elevations above 2000 ft. contact your local dealer or gas supplier before installing as input rating should be reduced approximately 4% for each 1000 ft. above sea level. Refer to the National Fuel Gas Code. Contact the Real Flame for more information at 1-800-654-1704 7 NATURAL GAS CONVERSION ! WARNING Before using this outdoor fire table, make sure you have read, understand and are following all information provided in the important Safety Information section of this manual. Failure to follow those instructions can cause death, serious injury or property damage. 13. CHECKING FOR LEAKS Make a leak check solution by mixing 1 part dishwashing soap with 3 parts water in a spray bottle. Make sure the control knob is “OFF.” Then, turn the Natural Gas on at its source. Spray leak solution on the valve connections, paying particular attention to the areas indicated by the arrows. If any bubbles appear turn the Natural Gas o˜ a t its source, reconnect and re-test. If you continue to see bubbles after several attempts, disconnect the Natural Gas Source and Contact Real Flame® at 1-800-654-1704 for assistance. If no bubbles appear after one minute turn the gas source “OFF”, wipe away solution and proceed. Check for leaks at these locations NOTE: The proper manifold pressure for this converted appliance is 7” water column. NOTE: The maximum inlet gas pressure for this unit is 10.5 in wc (2.61 kPa) The minimum inlet gas pressure for this unit is 3.5 in wc (0.87 kPa) 14.) Cut the existing French Plaque off of the control panel using wire cutters. Re-attach the French plaque and NG conversion plaque included with this kit to the fire table using the included cable kit. Re-attach both plaques Cut Cable 8 Lighting Instructions 15.) Lighting 1. 2. 3. 4. 5. 6. 7. Using the Igniter Read and understand all operating instructions before lighting. Burner control knob must be in the OFF position. Ensure that gas supply is connected and open Push and hold igniter button to create sparks. While holding the igniter button with one hand, use your other hand to push and turn the control knob to the LIGHT position to light the burner. Keep Burner Control Knob pressed in for 15-30 seconds after ignition. If ignition does not occur in 30 seconds, turn control knob to minutes until gas has cleared and repeat lighting procedure. 8. After lighting, rotate the Burner Control Knob counter clockwise to LOW setting. Observe flame, make sure all burner ports are lit. 9. Adjust the flame to the desired height with the control knob. Using a Long Match or Lighter 1. Wearing heat resistant gloves, position the burning long match or burning butane lighter near the side of the burner. DO NOT lean over the fire table while lighting. 2. Turn control knob counterclockwise to LIGHT. 3. Remove long match/long butane lighter. 4. After lighting, rotate the Burner Control Knob counter clockwise to LOW setting. Observe flame, make sure all burner ports are lit. 5. Adjust the flame to the desired height with the control knob. ! WARNING ! WARNING Control Knob LIGHT PUSH IN LOW 8-13” 20.3 - 30.5 cm If burner flame goes out during operation, immediately turn the control knob OFF and let the gas clear a minimum of 5 minutes before attempting to re-light the fire table. When using this method to light your fire table, use heat resistant gloves and follow the step by step instructions. Failure to do so could result in severe injury. 9 NOTES AND TECHNICAL SUPPORT For additional technical support call: 1-800-654-1704 Type of Gas / Type de gaz: NG/Natural Gas Normal Hourly Input/Entrée horaire normal: 65,000 BTU/Hr. (19.05 kW) Manifold Pressure/Pression d'admission: 7.0” water column (1.74 kPa) The minimum inlet pressure for this fire table is: C 3.5” water column (0.87 kPa) The maximum inlet pressure for this fire table is: 10.5” water column (2.61 kPa) ® US This appliance was converted on _________________ Cet appareil a été converti le (DD/MM/YY) to Natural Gas with Kit No._______________________ en gaz naturel avec le kit no. (Found on Box) by___________________________________________, par (Name and address of organization making this conversion) which accepts the responsibility that this conversion has been properly made. NOTES: ______________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ 10 Kit de conversion NG de CT0003LP Ledgestone de la table-foyer rectangular C ! US ! IMPORTANT CONSERVEZ CES INSTRUCTIONS ! DANGER immédiatement votre fournisseur de gaz ou le service des incendies. our le support technique veuillez contacter AVERTISSEMENT l’information fournie dans ce manuel n’est pas suivi à la lettre, un incendie ou une explosion entr nant des dommages corporels ou la perte de vie. Une mauvaise installation, d’ajustement, modification, service ou d’entretien peut causer des blessures ou des dommages matériels. Lisez l’installation, l’opération et des instructions de maintien à fond avant stallation ou entretien de cet équipement. ame à KIT DE CONVERSION DU GAZ NATUREL ! AVERTISSEMENT ! NOTE Ce kit de conversion doit être installé par un service d’entretien qualifié conformément aux instructions du Real Flame et tous les codes applicables et les exigences de l’autorité ayant la Juridiction. Si l’information dans ces instructions n’est pas suivi exactement, un incendie, une explosion ou la production de monoxyde de carbone peut causer des dommages matériels, des blessures corporelles ou la pertes de vie. Le service d’entretien qualifié est responsable de l’installation appropriée de ce kit. L’installation n’est pas bon et complet jusqu’à la fonctionnement de l’appareil converti est contrôlé comme spécifié dans les instructions du fabricant fournies avec ce kit. Ce kit de conversion est pour changer un table de feu de Pétrole Liquéfié (LP) dans une table de feu de Gaz naturel. LISTE DES PIECES 00023109S 1 Tuyau de gaz naturel et déconnexion rapide 4 Plaque de Conversion 2 Patate d’orifice NG 4.05mm 5 Kit de câble 3 Gaine de mixage d’air principal 5 1 4 CT000LP Ledgestone Conversion c h e m i n é e For technical support call: 1-800-654-1704 Pour d'assistance technique appelez : 1-800-654-1704 Type of Gas / Type de gaz: NG/Natural Gas Normal Hourly Input/Entrée horaire normal: 65,000 BTU/Hr. (19.05kW) 2 Manifold Pressure/Pression d’admission: 7.0" water column (1.74 kPa) / 7.0'' Colonne d'eau (1.74 kPa) The minimum inlet pressure for this fire table is: / La pression d'admission minimale pour cette table de feu est : 3.5" water column (0.87 kPa) / 3.5'' Colonne d'eau (0.87 kPa) The maximum inlet pressure for this fire table is: 10.5" water column (2.61 kPa) / 10.5'' Colonne d'eau (2.61 kPa) (Found on Box / Trouvé sur la Boîte) 3 (Name and address of organization making this conversion / Nom et adresse d'organisation qui fait cette conversion) 1 CONVERSION DU GAZ NATUREL 3.) Débrancher le soufflet (CSST) de la base de brûleur. 4.)Débrancher le soufflet (CSST) de la base du brûleur. Soufflet 2 CONVERSION DU GAZ NATUREL 5.) Retirez le patate d’orifice LP. le patate d’orifice LP 3 CONVERSION DU GAZ NATUREL 6.) Trouvez le nouveau patate d’orifice NG, vérifier qu’il n’est le bon numéro. Le numéro 4.05mm devrait être sur l’extrémité d’orifice de patate. 4.05mm 7.) Glissez le gaine sur l’ouverture aérienne principale voir fig. 1 Ensuite, vissez la nouvelle patate d’orifice NG dans la base de brûleur. Voir fig. 2 1 L’ouverture d’air principal 2 Gaine 4 Patate d’orifice NG CONVERSION DU GAZ NATUREL 8.) Rattachez les soufflets (CSST) à la nouvelle patate. Soufflets (CSST) 9.) Attachez le tuyau NG au côté d’entrée de la soupape. 5 CONVERSION DU GAZ NATUREL 10.) Attachez le déconnexion rapide à l’approvisionnement en gaz. Tuyauterie de Gaz naturel de Maison Soupape d'arrêt Prise de déconnexion rapide Tuyau de Gaz NG Au Table de Feu 6 CONVERSION DU GAZ NATUREL 11.) Après l’installation du kit de conversion, vérifiez l’emplacement du pilote, le thermocouple et l’épingle d’allumeur utilisant l’illustration ci-dessous. Thermocouple 5mm Igniter 12.) Avis aux techniciens d’installation. Vérifiez que la pression d’admission en utilisant un 3/8” raccord en tévasée à l’emplacement marqué par la flèche ci-dessous. Puis en utilisant un manomètre numérique vérifie que la pression avant l’orifice est 7” W.C. Vérifiez aussi que la patate d’orifice a la 4.05mm marqué. Ceci vous permettra de vérifier que l’évaluation d’entrée de l’appareil est correcte. Au manomètre Installation à Altitude Pour les installations à une altitude supérieure à 2000 pieds contactez votre revendeur local ou fournisseur de gaz avant l’installation comme l’évaluation d’entrée devrait être réduite d’environ 4% pour chaque 1000 pieds au-dessus du niveau de la mer. Référez-vous au Code de Gaz combustible national. Contactez Real Flame® pour plus d’information au 1-800-654-1704. 7 CONVERSION DU GAZ NATUREL ! AVERTISSEMENT Avant d’utiliser cette table de feu extérieure, assurez-vous que vous avez lu, comprenez et suivez toutes les informations fournies dans la section importante de l’information de Sécurité de ce manuel. L’échec de suivre ces instructions peut causer la mort, la blessure grave ou des dommages matériels. 13.) VÉRIFICATION POUR LES FUITES Faire une solution de contrôle d’étanchéité en mélangeant 1 partie de savon à vaisselle avec 3 parties d'eau dans un vaporisateur. Assurez-vous que le bouton de commande est « OFF ». Puis, tournez le sur le gaz naturel à sa source. Pulvériser la solution de fuite sur les connexions de valve, en accordant une attention particulière aux endroits indiqués par les èches. Mur Si des bulles apparaissent, tourner le gaz naturel à sa source, rebrancher et tester à nouveau. Si vous continuez à voir des bulles après plusieurs tentatives, débrancher la source de gas naturel et contacter Real Flame® à 1-800-654-1704 pour l’aide. Si aucune bulle n’apparaît après un minute, éteint la source de gaz, essuyer la solution et continuez. Vériÿez pour des fuites à ces emplacements NOTE : La pression d’admission appropriée pour cet appareil conv 14.) Coupez l’existante plaque française du panneau de contrôle utilisant un coup-fil. Rattachez la plaque française et la plaque de conversion NG incluse avec ce kit à la table. Rattachez les deux plaques Coupez le câble 8 Instructions d'allumage 15.) Éclairage Utilisation d’allumeur 1. 2. 3. 4. 5. Lisez et comprenez tout le mode d’emploi avant d’allumer. Le bouton de commande de brûleur doit être dans la pos Assurez que provisionnement en gaz est connecté et ouvert ser et maintenir le bouton mage pour créer des étincelles. En tenant le bouton d’allumeur d’une main, utilisez votre autre main pour pousser et tourner le bouton de commande vers la 6. 7. Bouton de commande 8. assurez-vous que tous les ports de brûleur sont allumés. 9. Ajustez la flamme à la hauteur désirée avec le bouton de commande. Utilisation d’une longue Allumette ou briquet 1. En portant des gants résistant à la chaleur, placez la longue allumette brûlant ou briquet au du brûleur. Ne penchez pas la table de feu en allumant. 2. Tournez le bouton de commande de tour en sens POUSSEE DANS 8-13” 20.3 - 30.5 cm 3. 4. Observez la flamme, assurez-vous que tous les ports de brûleur sont allumés. 5. Ajustez la flamme à la hauteur désirée avec le bouton de commande. ! O AVERTISSEMENT la flamme de brûleur s’éteint pendant l’opération, tournez immédiatement le bouton de commande sur et laisser le gaz dégage avec un minimu minutes avant d’essa er de rallumer la table de feu. ! AVERTISSEMENT En utilisant cette méthode pour allumer votre table de feu, utiliser des gants résistants à la chaleur 9 Pour d’assistance technique supplémentaire appelez: 1-800-654-1704 Type de gaz: GN/Gaz naturel Entrée horaire normal: 65,000 BTU/Hr. (19.05 kW) Pression d'admission: 7.0’’ Colonne d’au (1.74 kPa) La pression d'admission minimale pour cette table de feu est : 3.5’’ Colonne d’au (0.87 kPa) La pression d’admission maximum pour cette table de feu est : 10.5’’ Colonne d’au (2.61 kPa) ® C US Cet appareil a été converti _________________________ (DD/MM/YY) en Gaz naturel avec No. de Kit ______________________ (Trouvé sur la Boîte) par ____________________________________________, (Nom et adresse d’organisation qui fait cette conversion) qui accepte la responsabilité que cette conversion a été . NOTES: ______________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ 10 Kit de conversión a gas natural de la tabla de fuego CT0003LP Ledgestone C ! US ! IMPORTANTE GUARDE ESTAS INSTRUCCIONES ! PELIGRO Si siente olor a gas 1. Apague el artefacto 2. Extinguir cualquier llama abierta. 3. Si el olor continúa, manténgase alejado del artefacto y llame inmediatamente a su proveedor de gas o al departamento de bomberos. ADVERTENCIA Si la información contenida en este manual no se observa estrictamente, puede producirse un incendio o una explosión, causando daños materiales, lesiones personales o pérdida de vidas. La instalación, ajuste, alteración, servicio o mantenimiento en forma incorrecta pueden causar lesiones o daños a la propiedad. Lea atentamente las instrucciones de instalación, operación y mantenimiento antes de instalar o reparar este equipo. Para obtener asistencia técnica, póngase en contacto con Real Flame® llamando al: 1-800-654-1704 KIT DE CONVERSIÓN DE GAS NATURAL ! ADVERTENCIA ! AVISO Este kit de conversión debe ser instalado por una agencia de servicios calificada de acuerdo con las instrucciones de Real Flame y todos los códigos y requisitos aplicables de la Autoridad de Jurisdicción. Si la información contenida en estas instrucciones no se observa estrictamente, puede producirse monóxido de carbono, incendio o explosión, causando daños materiales, lesiones personales o pérdida de vidas. La agencia de servicio calificada es responsable de la correcta instalación de este kit. La instalación no es considerada correcta y completa hasta que el funcionamiento del artefacto convertido se compruebe como se especifica en las instrucciones del fabricante suministradas con este kit. Este kit de conversión es para convertir una tabla de fuego alimentada a petróleo licuado (LP) en una tabla de fuego alimentada a gas natural. LISTA DE PIEZAS 00023109S 1 Manguera de gas natural y desconexión rápida 4 Placa de conversión 2 Intermediario de orificio de GN 4.05mm 5 Juego de cables 3 Mezclador de aire primario 5 1 4 CT0003LP Ledgestone Conversion 2 40,000 BTU/Hr. (11.72kW) 3 1 CONVERSIÓN DE GAS NATURAL 3.) Desconecte el fuelle (CSST) de la base del quemador. 4.) Desconecte el fuelle (CSST) de la base del quemador. Fuelle 2 CONVERSIÓN DE GAS NATURAL 5.) Retire el intermediario de LP existente. Intermediario de LP 3 CONVERSIÓN DE GAS NATURAL 6.) Localice el nuevo intermediario de GN, compruebe que sea el número correcto. El número 4.05mm de be estar en el extremo del intermediario. 4.05mm 7.) Deslice la manga sobre la abertura de aire primario. Ver fig 1. Luego, atornille el nuevo intermediario de GN en la base del quemador. Ver fig 2. 1 Apertura de aire primario 2 Manga 4 Intermediario de GN CONVERSIÓN DE GAS NATURAL 8.) Vuelva a conectar el fuelle (CSST) al nuevo intermediario. Fuelle 9.) Conecte la manguera de GN a la entrada de la válvula. 5 CONVERSIÓN DE GAS NATURAL 10.) Conecte la desconexión rápida al suministro de gas. Tubo de gas natural Válvula de cierre Conexión de la desconexión rápida Manguera de gas GN A la tabla de fuego 6 CONVERSIÓN DE GAS NATURAL 11.) Después de instalar el kit de conversión, verifique la ubicación del piloto, el termo acople y el pin encendedor utilizando la ilustración a continuación. 5mm Thermocouple Igniter 12.) Nota para técnicos de instalación. Verifique la presión del colector usando un empalme en T de 3/8” en el lugar marcado por la flecha abajo. Luego, usando un manómetro digital, verifique que la presión antes del orificio sea de 7” W.C. también verifique que el intermediario tenga la marca 4.05mm esto le permitirá verificar que la capacidad de entrada del artefacto es correcta. Al manómetro Instalación en altitudes Para instalaciones en altitudes superiores a 2000 pies, póngase en contacto con su distribuidor local o proveedor de gas antes de la instalación, ya que la capacidad de entrada debe reducirse aproximadamente un 4% por cada 1000 pies de altura sobre el nivel del mar. Consulte el Código Nacional de Gas Combustible. Contacte a Real Flame® para obtener más información al 1-800-654-1704 7 CONVERSIÓN DE GAS NATURAL ! ADVERTENCIA Antes de usar esta tabla de fuego de exteriores, asegúrese de haber leído, comprendido y seguido toda la información proporcionada en la sección 'Información de seguridad importante' de este manual. El incumplimiento de dichas instrucciones puede ocasionar lesiones graves, daños a la propiedad o la muerte. 13.) VERIFICAR FUGAS Haga una solución de control de fugas mezclando 1 parte de detergente/ jabón lavavajillas con 3 partes de agua en una envase pulverizador. Asegúrese de que la perilla de control esté en la posición "OFF". A continuación, abra el suministro de gas natural. Rocíe la solución de fugas en las conexiones de la válvula, prestando especial atención a las áreas indicadas por las ˝echas. Si aparecen burbujas, cierre el suministro de gas, vualva a conectar y vuelva a probar. Si continúa viendo burbujas después de varios intentos, cierre el suministro de gas natural y llame a Real Flame® al 1-800-654-1704 para obtener ayuda. Pared Si no aparecen burbujas después de un minuto, cierre el suministro de gas ("OFF"), limpie la solución y proceda. Compruebe si hay fugas en estas ubicaciones AVISO: La presión adecuada del colector para este artefacto convertido es de 7" de columna de agua. AVISO: La presión de gas de entrada máxima para esta unidad es de 10.5 en wc (2.61 kPa) La presión de gas de entrada mínima para esta unidad es de 3.5 en wc (0.87 kPa) 14.) Cortar la placa existente en francés del panel de control usando cortadores de alambre. Vuelva a colocar la placa en francés y la placa de conversión a GN incluidas con este kit en la tabla de fuego usando el juego de cables incluido. Colocar nuevamente las placas Cortar el cable 8 Instrucciones de encendido 15.) Encendido Uso del encendedor 1. Lea y comprenda todas las instrucciones de funcionamiento antes de encender. 2. La perilla de control del quemador debe estar en la posición OFF. 3. Asegúrese de que el suministro de gas esté conectado y abierto 4. Presione y mantenga presionado el botón del encendedor para generar chispas. 5. Mientras sostiene el botón del encendedor con una mano, use la otra mano para empujar y girar la perilla de control a la posición LIGHT (ENCENDIDO) para encender el quemador. 6. Mantenga presionada la perilla de control del quemador durante 15-30 segundos después de encender. 7. Si la ignición no ocurre en 30 segundos, gire la perilla de control a la posición OFF y cierre el suministro de gas, espere 5 minutos hasta que se haya despejado el gas y repita el procedimiento de encendido. 8. Después de encender, gire la perilla de control del quemador en sentido anti horario hasta el ajuste LOW (BAJO). Observe la llama, asegúrese de que todos los puertos del quemador estén encendidos. 9. Ajuste la llama a la intensidad deseada mediante la perilla de control. Usando un fósforo largo o encendedor 1. Usando guantes resistentes al calor, coloque el fósforo largo encendido o encendedor de gas butano encendido próximo al lateral del quemador. NO SE INCLINE sobre tabla de fuego mientras la enciende. 2. Gire la perilla de control en sentido antihorario a LIGHT (ENCENDIDO). 3. Retire el fósforo largo / encendedor de gas butano. 4. Después de encender, gire la perilla de control del quemador en sentido anti horario hasta el ajuste LOW (BAJO). Observe la llama, asegúrese de que todos los puertos del quemador estén encendidos. 5. Ajuste la llama a la intensidad deseada mediante la perilla de control. ! ADVERTENCIA ! ADVERTENCIA Perilla de control LIGHT (ENCENDIDO) PUSH IN (PRESIONAR) LOW (BAJO) 8-13” 20.3 - 30.5 cm Si la llama del quemador se apaga durante el funcionamiento, gire inmediatamente la perilla de control a la posición OFF deje que el gas desaparezca por lo menos durante 5 minutos antes de intentar volver a encender la mesa de fuego. Cuando use este método para encender su mesa de fuego, utilice guantes resistentes al calor y siga las instrucciones paso a paso. No hacerlo, podría ser la causa de lesiones graves. 9 NOTAS Y SOPORTE TÉCNICO Para obtener soporte técnico adicional, llame a: 1-800-654-1704 Tipo de gas: Gas natural / GN Entrada normal por hora: 65,000 BTU/Hr. (19.05 kW) Presión de admisión: 7.0” columna de agua (1.74 kPa) La presión de entrada mínima para esta tabla de fuego es: C 3.5” columna de agua (0.87 kPa) La presión de entrada máxima para esta tabla de fuego es: 10.5” columna de agua (2.61 kPa) ® US Este artefacto fue convertido el: _________________ (DD/MM/AA) A gas natural con el kit Nro._____________________ (Encontrado en la caja) por__________________________________________, (Nombre y dirección de la organización que realiza esta conversión) Que acepta la responsabilidad de que esta conversión fue hecha correctamente. NOTAS: ______________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ 10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33

Real Flame CT0003LP-GLS El manual del propietario

Tipo
El manual del propietario