DESCRIPTION
Series 314 are direct operated 3/2 solenoid valves. The solenoid
valves have normally closed operation, air only - with an exhaust
to atmosphere on top of the solenoid. The valve body is brass
construction.
INSTALLATION
ASCO Numatics components are intended to be used only
within the technical characteristics as specified on the nameplate.
Changes to the equipment are only allowed after consulting the
manufacturer or its representative. Before installation depressurise
the piping system and clean internally. The equipment may be
mounted in any position. Connect piping to valve according to
markings on valve body.
The pipe connections have to be in accordance with the size
indicated on the nameplate and fitted accordingly.
Caution:
Reducing the connections may cause improper operation or
malfunctioning.
For the protection of the equipment install a strainer or filter
suitable for the service involved in the inlet side as close to
the product as possible.
If tape, paste, spray or a similar lubricant is used when tight-
ening, avoid particles entering the system.
Use proper tools and locate wrenches as close as possible to
the connection point.
To avoid damage to the equipment, DO NOT OVERTIGHTEN
pipe connections.
Do not use valve or solenoid as a lever.
The pipe connections should not apply any force, torque or
strain to the product.
ELECTRICAL CONNECTION
In case of electrical connections, they are only to be made by
trained personnel and have to be in accordance with the local
regulations and standards.
Caution:
Turn off electrical power supply and de-energise the electrical
circuit and voltage carrying parts before starting work.
All electrical screw terminals must be properly tightened
according to the standards before putting into service.
Dependent upon the voltage electrical components must be
provided with an earth connection and satisfy local regulations
and standards.
The equipment can have one of the following electrical terminals:
Spade plug connections according to ISO 4400 (when correctly
installed this connection provides lP-65 protection).
Embedded screw terminals in metal enclosure with “Pg” cable
gland.
Flying leads or cables.
PUTTING INTO SERVICE
Before pressurising the system, first carry-out an electrical test.
In case of solenoid valves, energise the coil a few times and notice
a metal click signifying the solenoid operation.
SERVICE
Most of the solenoid valves are equipped with coils for continuous
duty service. To prevent the possibility of personal or property dam-
age do not touch the solenoid which can become hot under normal
operation conditions. If the solenoid valve is easily accessible,
the installer must provide protection preventing accidental contact.
SOUND EMISSION
The emission of sound depends on the application, medium and
nature of the equipment used. The exact determination of the
sound level can only be carried out by the user having the valve
installed in his system.
MAINTENANCE
Maintenance of ASCO Numatics products is dependent on service
conditions. Periodic cleaning is recommended, the timing of which
will depend on the media and service conditions. During servicing,
components should be examined for excessive wear. A complete
set of internal parts is available as a spare parts kit. If a problem
occurs during installation/maintenance or in case of doubt please
contact ASCO Numatics or authorised representatives.
VALVE DISASSEMBLY
Disassemble in an orderly fashion. Pay careful attention to exploded
views provided for identification of parts.
1. Remove retaining clip and coil. CAUTION: when metal retaining
clip disengages, it can spring upwards. Then remove the spring
washer.
2. Unscrew the solenoid base sub-assembly and remove its
O-ring.
3. Remove the core assembly, core guide and core spring.
4. All parts are now accessible for cleaning or replacement.
VALVE REASSEMBLY
Reassemble in reverse order of disassembly paying careful
attention to exploded views provided for identification and
placement of parts.
1. NOTE: Lubricate all gaskets/O-rings with high quality silicone
grease.
2. Replace core spring, core assembly, and core guide.
3. Replace solenoid base sub-assembly O-ring and torque
solenoid base sub-assembly according to torque chart.
4. Replace spring washer, coil and retaining clip.
5. After maintenance, operate the valve a few times to be sure
of proper operation.
For additional information visit our website: www.asco.com
DESCRIPTION
Les vannes de la série 314 font partie de la gamme des élec-
trovannes 3/2 à commande directe. Les électrovannes fonctionnent
normalement fermées, uniquement à air - elles sont équipées d’un
échappement dans l’atmosphère situé au-dessus de l’électrovanne.
Le corps est en laiton.
MONTAGE
Les composants ASCO Numatics sont conçus pour les do-
maines de fonctionnement indiqués sur la plaque signal-étique
ou la documentation. Aucune modification ne peut être réalisée
sur le matériel sans l’accord préalable du fabricant ou de son
représentant. Avant de procéder au montage, dépressuriser les
canalisations et effectuer un nettoyage interne. Les électrovannes
peuvent être monté dans n’importe quelle position. Connecter la
canalisation à l’électrovanne selon les indications indiquées sur le
corps de l’électrovanne.
La dimension des tuyauteries doit correspondre au raccordement
indiqué sur le corps, l’étiquette ou la notice.
Attention:
Une restriction des tuyauteries peut entraîner des dysfonc-tion-
nements.
Afin de protéger le matériel, installer une crépine ou un filtre
adéquat en amont, aussi près que possible du produit.
En cas d’utilisation de ruban, pâte, aérosol ou un lubrifiant lors
du serrage, veillez à ce qu’aucun corps étranger ne pénétre
dans le circuit.
Utiliser un outillage approprié et placer les clés aussi près que
possible du point de raccordement.
Afin d’éviter toute détérioration, NE PAS TROP SERRER les
raccords des tuyauteries.
Ne pas se servir de la vanne ou de la tête magnétique comme
d’un levier.
Les tubes de raccordement ne devront exercer aucun effort,
couple ou contrainte sur le produit.
RACCORDEMENT ÉLECTRIQUE
Le raccordement électrique doit être réalisé par un personnel
qualifié et selon les normes et règlements locaux.
Attention:
Avant toute intervention, couper l’alimentation électrique pour
mettre hors tension les composants.
Toutes les bornes à vis doivent être serrées correctement avant
la mise en service.
Selon la tension, les composants électriques doivent être mis
à la terre conformément aux normes et règlements locaux.
Selon les cas, le raccordement électrique s’effectue par:
Connecteur débrochable ISO 4400 avec degré de protection
IP-65 lorsque le raccordement est correctement effectué.
Bornes à vis solidaires du bobinage, sous boîtier métallique
avec presse-étoupe étanche “Pg”.
Fils ou câbles solidaires de la bobine.
MISE EN SERVICE
Avant de mettre le circuit sous pression, effectuer un essai
électrique. Dans le cas d’une électrovanne, mettre la bobine sous
tension plusieurs fois et écouter le “clic” métallique qui signale le
fonctionnement de la tête magnétique.
FONCTIONNEMENT
La plupart des électrovannes comportent des bobinages prévus
pour mise sous tension permanente. Pour éviter toute brûlure,
ne pas toucher la tête magnétique qui, en fonctionnement normal
et en permanence sous tension, peut atteindre une température
élevée. Si l’électrovanne est facilement accessible, l’installateur
doit prévoir une protection empêchant tout contact accidentel.
BRUIT DE FONCTIONNEMENT
Le bruit de fonctionnement varie selon l’utilisation, le fluide et
le type de matériel employé. L’utilisateur ne pourra déterminer
avec précision le niveau sonore émis qu’après avoir monté le
composant sur l’installation.
ENTRETIEN
L’entretien nécessaire aux produits ASCO Numatics varie avec
leurs conditions d’utilisation. Il est souhaitable de procéder à un
nettoyage périodique dont l’intervalle varie suivant la nature du
fluide, les conditions de fonctionnement et le milieu ambiant. Lors
de l’intervention, les composants doivent être examinés pour
détecter toute usure excessive. Un ensemble de pièces internes
est proposé en pièces de rechange pour procéder à la réfection.
En cas de problème lors du montage/entretien ou en cas de doute,
veuillez contacter ASCO Numatics ou ses représentants officiels.
DEMONTAGE DE LA VANNE
Démonter de façon méthodique. sur les vues en éclaté fournies
dans la pochette et destinées à l’identification des pièces.
1. Ôtez le clip de maintien et la bobine. ATTENTION: lorsque le
clip de maintien métallique est ôté, il peut bondir vers le haut.
Puis ôter la rondelle élastique.
2. visser le sous-ensemble de base de la tête magnétique et
ôter son joint torique.
3. Ôter le montage du noyau, le glissoir du noyau et le ressort
du noyau.
4. Vous pouvez dès à présent nettoyer ou remplacer toutes les
pièces.
REMONTAGE DE LA VANNE
Remonter en sens inverse.
1. NOTE: Lubrifier tous les joints d’étanchéité/joints toriques avec
de la graisse silicone de haute qualité.
2. Replacer le ressort du noyau, le montage du noyau et le glissoir
du noyau.
3. Replacer le joint torique du sous-ensemble de base de la tête
magnétique et raccorder le sous-ensemble de base de la tête
magnétique selon le schéma de couple.
4. Replacer la rondelle élastique du ressort, la bobine et le clip
de maintien.
5. Après l’entretien, faire fonctionner la vanne quelques fois afin
de s’assurer qu’elle s’ouvre et se ferme correctement.
Pour toute information complémentaire, veuillez consulter
notre site Web: www.asco.com
BESCHREIBUNG
Bei der Baureihe 314 handelt es sich um direkt betätigte 3/2-Ma-
gnetventile. Die Magnetventile sind für normal geschlossenen
Betrieb und ausschließlich für Luft geeignet und besitzen eine
Entlüftung zur Atmosphäre an der Oberseite des Magnetkopfs.
Das Ventilgehäuse besteht aus Messing.
EINBAU
Die ASCO Numatics-Komponenten dürfen nur innerhalb der auf
den Typenschildern angegebenen Daten eingesetzt werden.
Veränderungen an den Produkten sind nur nach Rücksprache
mit ASCO Numatics zulässig. Vor dem Einbau der Ventile muß
das Rohrleitungssystem drucklos geschaltet und innen gereinigt
werden. Die Einbaulage der Produkte ist generell beliebig. Lei-
tungen entsprechend den Markierungen am Ventilgehäuse mit
dem Ventil verbinden.
Die Rohrleitungsanschlüsse sollten entsprechend den Größen-
angaben auf den Typenschildern mit handelsüblichen Verschraub-
ungen durchgeführt werden.
Vorsicht:
Eine Reduzierung der Anschlüsse kann zu Leistungs- und
Funktionsminderungen führen.
Zum Schutz der Ventile sollten für die Betriebsbedingungen
geeignete Schmutzfänger oder Filter so dicht wie möglich in
den Ventileingang integriert werden.
Bei Abdichtung am Gewinde ist darauf zu achten, daß kein
Dichtungsmaterial in die Rohrleitung oder das Ventil gelangt.
Zum Einbau darf nur geeignetes Werkzeug verwendet werden,
das so nahe wie möglich am Anschlußpunkt anzusetzen ist.
Um eine Beschädigung der Produkte zu vermeiden, ist darauf
zu achten, daß die Rohranschlüsse NICHT ZU STARK ANGE-
ZOGEN werden.
Spule und Führungsrohr von Ventilen dürfen nicht als Gegen-
halter benutzt werden.
Die Rohrleitungsanschlüsse sollten fluchten und dürfen keine
Spannungen auf das Ventil übertragen.
ELEKTRISCHER ANSCHLUSS
Der elektrische Anschluß ist von Fachpersonal entsprechend den
geltenden VDE- und CEE-Bestimmungen auszuführen.
Vorsicht:
Vor Beginn der Arbeiten ist sicherzustellen, daß alle elek-
trischen Leitungen und Netzteile spannungslos geschaltet sind.
Alle Anschlußklemmen sind nach Beendigung der Arbeiten
vorschriftsmäßig entsprechend den geltenden Normen anzu-
ziehen.
Je nach Spannungsbereich muß das Ventil nach den geltenden
Bestimmungen und Normen einen Schutzleiter-anschluß
erhalten.
Der Magnetantrieb kann je nach Bauart folgende elektrische
Anschlüsse aufweisen
Flachsteckeranschlüsse gemäß ISO 4400 (bei ordnungs-
gemäßer Montage ist Schutzart IP-65 gewährleistet).
Anschlüsse innerhalb eines Metallgehäuses mittels Schraub-
klemmen. Kabeleinführung ins Gehäuse mit PG- Verschrau-
bung.
Eingegossene Kabelenden.
INBETRIEBNAHME
Vor Druckbeaufaufschlagung des Produktes sollte eine elektrische
Funktionsprüfung erfolgen: Bei Magnetventilen Spannung an
der Magnetspule mehrmals ein- und ausschalten. Es muß ein
metallisches Klicken zu hören sein.
BETRIEB
Die meisten Magnetventile sind mit Spulen für Dauerbetrieb
ausgerüstet. Zur Vermeidung von Personen- und Sachschäden
sollte jede Berührung der Magnetspule vermieden werden,
da diese unter normalen Betriebsbedingungen sehr heiß werden
kann. Bei leicht zugänglichem Magnetventil sollte vom Installateur
ein Schutz vorgesehen werden, um jegliches versehentliches
Berühren zu vermeiden.
GERÄUSCHEMISSION
Die Geräuschemission hängt sehr stark vom Anwendungsfall, dem
Medium, mit denen das Produkt beaufschlagt wird, und der Art des
verwendeten Produktes ab. Die exakte Bestimmung des Geräusch-
pegels kann aus diesem Grund nur durch die Person durchgeführt
werden, die das Ventil in das jeweilige System eingebaut hat.
WARTUNG
Die Wartung hängt von den Betriebsbedingungen ab. Es wird
empfohlen, das Produkt regelmäßig zu reinigen, wobei sich die
Zeitabstände nach dem Medium und den Betriebsbedingungen
richten. Während der Wartung sollten die Komponenten auf
übermäßigen Verschleiß überprüft werden. Für die Überholung
der ASCO Numatics-Produkte sind komplette Sätze mit internen
Teilen als Ersatzteilsätze erhältlich. Treten Schwierigkeiten bei
Einbau, Betrieb oder Wartung auf sowie bei Unklarheiten, ist mit
ASCO Numatics Rücksprache zu halten.
VENTILDEMONTAGE
Das Ventil muß in der angegebenen Reihenfolge zerlegt werden.
Dabei sind die Teile exakt anhand der mitgelieferten Explosions-
zeichnungen zu identifizieren.
1. Halteklammer und Spule entfernen. ACHTUNG: Die Klam-
merhalterung kann beim Lösen nach oben wegfedern. Dann
Federscheibe entfernen.
2. Haltemutter lösen und zugehörigen Dichtungsring ausbauen.
3. Magnetankerbaugruppe, Führungsrohr und Magnetankerfeder
entfernen.
4. Nun sind alle Teile, die gereinigt oder ausgetauscht werden
müssen, leicht zugänglich.
VENTILZUSAMMENBAU
Ventil in der umgekehrten Reihenfolge wie bei der Demontage
zusammenbauen. Dabei sind die Teile anhand der Explosions-
zeichnungen zu identifizieren und anzuordnen.
1. HINWEIS: Alle Dichtungen/Dichtungsringe sind mit hoch-
wertigem Silikonfett zu schmieren.
2. Magnetankerfeder, Magnetankerbaugruppe und Führungsrohr
wieder montieren.
3. Haltemutter-Dichtungsring wieder montieren und Haltemutter
entsprechend den Angaben im Drehmomentdiagramm anziehen.
4. Federscheibe, Spule und Halteklammer wieder anbringen.
5. Nach der Wartung Ventil mehrmals betätigen, um sicherzu-
stellen, daß es ordnungsgemäß funktioniert.
Weitere Informationen finden Sie auf unserer Website:
www.asco.com
DESCRIPCION
La Serie 314 está formada por válvulas de solenoide de 3/2
de accionamiento directo. Las válvulas de solenoide son de
funcionamiento normalmente cerrado, sólo de aire; con escape
a la atmósfera en la parte superior del solenoide. El cuerpo de la
válvula está construido de latón.
INSTALACION
Los componentes ASCO Numatics sólo deben utilizarse dentro de
las especificaciones técnicas que se especifican en su placa de
características. Los cambios en el equipo sólo estarán permitidos
después de consultar al fabricante o a su representante. Antes
de la instalación, despresurice el sistema de tuberías y limpie
internamente. El equipo puede utilizarse en cualquier posición.
Conecte la tubería a la válvula según las marcas que se encuentran
en el cuerpo de la válvula.
Las conexiones a la tubería deben corresponder al tamaño in-
di-cado en la placa de características y ajustarse adecuadamente.
Precaución:
La reducción de las conexiones puede causar operaciones
incorrectas o defectos de funcionamiento.
Para la protección del equipo se debe instalar en la parte de
la entrada y tan cerca como sea posible del producto un filtro
o tamizador adecuado para el servicio.
Si se utilizara cinta, pasta, spray u otros lubricantes en el ajuste,
se debe evitar que entren partículas en el producto.
Se debe utilizar las herramientas adecuadas y colocar llaves
lo más cerca posible del punto de conexión.
Para evitar daños al equipo, NO FORZAR las conexiones a la
tubería.
No utilizar la válvula o el solenoide como palanca.
Las conexiones a la tubería no producirán ninguna fuerza,
apriete o tensión sobre el producto.
CONEXION ELECTRICA
En caso de requerirse conexiones eléctricas, estas serán realiza-
das por personal cualificado y deberán adaptarse a las normas
y regulaciones locales.
Precaución:
Antes de comenzar el trabajo, desconecte el suministro de
energía eléctrica y desenergice el circuito electrónico y los
elementos portadores de tensión.
Todos los terminales eléctricos deben estar apretados ade-cua-
damente según normas antes de su puesta en servicio.
Según el voltaje, los componentes electrónicos deben disponer
de una conexión a tierra y satisfacer las normas y regulaciones
locales.
El equipo puede tener uno de los siguientes terminales eléctricos:
Conexiones desenchufables según ISO 4400 (cuando se instala
correctamente, esta conexión proporciona la protección IP-65).
Terminales de tornillo con carcasa metálica con entrada de
cable de conexión roscada «PG».
Salida de cables.
PUESTA EN MARCHA
Se debe efectuar una prueba eléctrica antes de someter a presión
el sistema. En el caso de las válvulas solenoides, se debe energizar
varias veces la bobina y comprobar que se produce un sonido
metálico que indica el funcionamiento del solenoide.
SERVICIO
La mayor parte de las válvulas solenoides se suministran con
bobinas para un servicio continuo. Con el fin de evitar la posibilidad
de daños personales o materiales no se debe tocar el solenoide,
ya que puede haberse calentado en condiciones normales de
trabajo. Si la electroválvula es de fácil acceso, el instalador debe
prever una protección que impida cualquier contacto accidental.
EMISION DE RUIDOS
La emisión de ruidos depende de la aplicación, medio y naturaleza
del equipo utilizado. Una determinación exacta del nivel de ruido
solamente se puede llevar a cabo por el usuario que disponga la
válvula instalada en su sistema.
MANTENIMIENTO
El mantenimiento de los productos ASCO Numatics depende de
las condiciones de servicio. Se recomienda una limpieza periódica,
dependiendo de las condiciones del medio y del servicio. Durante
el servicio, los componentes deben ser examinados por si hubiera
desgastes excesivos. Se dispone de un juego completo de partes
internas como recambio. Si ocurriera un problema durante la
instalación/mantenimiento o en caso de duda contactar con
ASCO Numatics o representantes autorizados.
DESMONTAJE DE LA VALVULA
Desmonte la válvula ordenadamente. Preste especial atención a
las vistas ampliadas que se suministran para identificar las partes.
1. Retire el clip de sujeción y la bobina. PRECAUCION: al des-
engancharse el clip de sujeción metálico, éste puede saltar
hacia arriba. A continuación retire la arandela resorte.
2. Desatornille el conjunto de la base auxiliar del solenoide y
retire su junta.
3. Retire el conjunto del núcleo, la guía del núcleo y el resorte
del núcleo.
4. Ahora tendrá acceso a todas las piezas para su limpieza o
sustitución.
REMONTAJE DE LA VALVULA
Vuelva a montar la válvula en el orden inverso de desmontaje
prestando especial atención a las vistas ampliadas suministradas
para identificar e instalar las partes.
1. NOTA: Lubrique todas las guarniciones/juntas con grasa de
silicona de buena calidad.
2. Vuelva a colocar el resorte del núcleo, el conjunto del núcleo
y la guía del núcleo.
3. Vuelva a colocar la arandela del conjunto de la base auxiliar
del solenoide y apriete el conjunto auxiliar de la base del
solenoide según el cuadro de apriete.
4. Vuelva a colocar la arandela resorte, la bobina y el clip de
sujeción.
5. Después de realizado el mantenimiento, opere la válvula unas
cuantas veces para asegurarse de su correcto funcionamiento.
Para obtener información adicional, visite nuestro sitio Web:
www.asco.com
INSTALLATION AND MAINTENANCE INSTRUCTIONS
direct operated
1/4
INSTRUCTIONS D’INSTALLATION ET D’ENTRETIEN
à commande directe
1/4
BETRIEBSANLEITUNG
Magnetventil direkt betätigt
1/4
INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO
accionada directamente
1/4
1
23
1
23
1
23
1
23
IT NL
DRAWING DESSIN ZEICHNUNG
DISEGNO DIBUJO TEKENING
DRAWING DESSIN ZEICHNUNG
DISEGNO DIBUJO TEKENING
GB
DESCRIPTION
FR
DESCRIPTION
DE
BESCHREIBUNG
ES
DESCRIPCION
IT
DESCRIZIONE
NL
BESCHRIJVING
www.asco.com
123620-658 (535-03)
Page 2 of 2 Modied on: 2017-10-03
SERIES
314
GB
¬ Supplied in spare part kit
FR
¬ Livrées en pochette de rechange
DE
¬ Enthalten im Ersatzteilsatz
ES
¬ Incluido en Kit de recambio
IT
¬ Disponibile nel Kit parti di ricambio
NL
¬ Geleverd in vervangingsset
A 0,6±0,2 5±2
B 20±3 175±25
ITEMS NEWTON.METRES INCH.POUNDS
TORQUE CHART
Ø
Catalogue number
Code électrovanne
Katalognummer
Código de la electrovalvula
Codice elettrovalvola
Katalogus nummer
Spare part kit
Code pochette de rechange
Ersatzteilsatz
Código del kit de recambio
Kit parti di ricambio
Vervangingsset
1/4
SCB 314C22
SCB 314C23
SCB 314C24
~ =
C302-869
C302-870
C302-871
-
-
-
DESCRIZIONE
La Serie 314 comprende elettrovalvole a comando diretto a 3 vie.
Le elettrovalvole sono in versione normalmente chiusa, solo aria - con
scarico in atmosfera sul solenoide. Il corpo è in ottone.
INSTALLAZIONE
Le elettrovalvole ASCO Numatics devono essere utilizzate
esclusivamente rispettando le caratteristiche tecniche specificate
sulla targhetta. Variazioni sulle elettrovalvole sono ammissibili solo
dopo avere consultato il costruttore o il suo rappresentante. Prima
dell’installazione, depressurizzare i tubi e pulire internamente. Le
elettrovalvole possono essere montate in tutte le posizioni. Collega-
re i tubi alla valvola seguendo le marcature sul corpo della valvola.
I raccordi devono essere conformi alla misura indicata sull’
apposita targhetta.
Attenzione:
Ridurre i raccordi può causare operazioni sbagliate o malfun-
zionamento.
Per proteggere il componente installare, il più vicino possibile
al lato ingresso, un filtro adatto al servizio.
Se si usano nastro, pasta spray o lubrificanti simili durante il
serraggio, evitare che delle particelle entrino nel corpo della
valvola.
Usare attrezzature appropriate e posizionare le chiavi il più
vicino possibile al punto di raccordo.
Per evitare danni al corpo della valvola, NON SERRARE
ECCESSIVAMENTE i raccordi.
Non usare la valvola o il solenoide come una leva.
I raccordi non devono esercitare pressione, torsione o solle-
citazione sull’ elettrovalvola.
ALLACCIAMENTO ELETTRICO
L’allacciamento elettrico deve essere effettuato esclusivamente da
personale specializzato e deve essere conforme alle norme locali.
Attenzione:
Prima di mettere in funzione, togliere l’alimentazione elettrica,
diseccitare il circuito elettrico e le parti sotto tensione.
I morsetti elettrici devono essere correttamente avvitati
secondo le norme prima della messa in servizio.
Le elettrovalvole devono essere provviste di morsetti di terra
a seconda della tensione e delle norme di sicurezza locali.
I piloti possono avere una delle seguenti caratteristiche elettriche:
Connettori a spada secondo ISO 4400 (se correttamente
installata, questa connessione fornisce protezione IP-65).
Morsettiera racchiusa in custodia metallica. Entrata cavi con
pressacavi tipo “Pg”.
Bobine con fili o cavo.
MESSA IN FUNZIONE
Prima di dare pressione alla valvola, eseguire un test elettrico.
Eccitare la bobina diverse volte fino a notare uno scatto metallico
che dimostra il funzionamento del solenoide.
SERVIZIO
Molte elettrovalvole sono provviste di bobine per il funzionamento
continuo. Per prevenire la possibilità di danneggiare cose o perso-
ne, non toccare il solenoide. Se di facile accesso, l’elettrovalvola
deve essere protetta per evitare qualsiasi contatto accidentale.
EMISSIONE SUONI
L’emissione di suoni dipende dall’applicazione e dal tipo di elettro-
valvola. L’utente può stabilire esattamente il livello del suono solo
dopo aver installato la valvola sul suo impianto.
MANUTENZIONE
Generalmente questi componenti non necessitano spesso di
manutenzione. Comunque in alcuni casi è necessario fare atten-
zione a depositi o ad eccessiva usura. Questi componenti devono
essere puliti periodicamente. Il tempo che intercorre tra una pulizia
e l’altra varia a seconda delle condizioni di funzionamento. Il ciclo di
durata dei componenti dipende dalle condizioni di funzionamento.
In caso di usura è disponibile un set completo di parti interne per
la revisione. Se si incontrano problemi durante l’installazione e la
manutenzione o se si hanno dei dubbi, consultare ASCO Numatics
o i suoi rappresentanti.
SMONTAGGIO VALVOLE
Smontare procedendo con ordine. Consultare attentamente gli
esplosi forniti per una corretta identificazione delle parti.
1. Smontare la clip di fissaggio e la bobina. ATTENZIONE:
Quando si sgancia la clip metallica di fissaggio, può scattare
verso l’alto. Poi smontare la ghiera.
2. Svitare il sottogruppo di base del solenoide e smontare l’anello
di ritenuta.
3. Smontare il gruppo del nucleo, il guida-nucleo e la molla del
nucleo.
4. Ora tutte le parti sono accessibili per la pulizia o la sostituzione.
RIMONTAGGIO VALVOLA
Rimontare procedendo nell’ordine inverso facendo riferimento
agli esplosi forniti per la corretta identificazione e collocazione
delle parti.
1. NOTA: Lubrificare tutte le guarnizioni/anelli di tenuta con grasso
al silicone d’alta qualità.
2. Rimontare la molla del nucleo, il gruppo del nucleo e il guida
nucleo.
3. Rimontare l’anello di ritenuta del sottogruppo di base del sole-
noide e serrare il sottogruppo di base del solenoide secondo
la tabella delle coppie.
4. Rimontare la ghiera, la bobina e la clip di fissaggio.
5. Dopo la manutenzione, azionare ripetutamente la valvola per
accertarne il corretto funzionamento.
Per informazioni aggiuntive, visitate il nostro sito web:
www.asco.com
BESCHRIJVING
Afsluiters uit de 314-serie zijn direct werkende 3/2-magneetafslui-
ters. De magneetafsluiters zijn geschikt voor normaal gesloten
gebruik, met uitsluitend lucht - en zijn voorzien van een afvoer
naar de atmosfeer bovenop de magneetkop. Het afsluiterhuis
is van messing.
INSTALLATIE
ASCO Numatics producten mogen uitsluitend toegepast worden
binnen de op de naamplaat aangegeven specificaties. Wijzigingen
zijn alleen toegestaan na overleg met de fabrikant of haar verte-
genwoordiger. Voor het inbouwen dient het leidingsysteem drukloos
gemaakt te worden en inwendig gereinigd. De positie van de afslui-
ter is naar keuze te bepalen. Kijk naar de markeringen op het huis
voor het aansluiten van de aan- en afvoerleidingen op de afsluiter.
De pijpaansluiting moet overeenkomstig de naamplaatgegevens
plaatsvinden.
Let op:
Een reductie van de aansluitingen kan tot prestatie en func-
tiestoornis leiden.
Ter bescherming van de interne delen wordt een filter in het
leidingnet aanbevolen.
Bij het gebruik van draadafdichtingspasta of tape mogen er
geen deeltjes in het leidingwerk geraken.
Men dient uitsluitend geschikt gereedschap voor de montage
te gebruiken.
Gebruik een zodanig koppel voor leidingverbindingen dat het
product NIET WORDT BESCHADIGD.
Het product, de behuizing of de spoel mag niet als hefboom
worden gebruikt.
De pijpaansluitingen mogen geen krachten of momenten op
het product overdragen.
ELEKTRISCHE AANSLUITING
In geval van elektrische aansluiting dient dit door vakkundig
personeel te worden uitgevoerd volgens de door de plaatselijke
overheid bepaalde richtlijnen.
Let op:
Voordat men aan het werk begint moeten alle spannings-voe-
rende delen spanningsloos worden gemaakt.
Alle aansluitklemmen moeten na het beëindigen van het werk
volgens de juiste normen worden aangedraaid.
Al naar gelang het spanningsbereik moet het product volgens
de geldende normen van een aarding worden voorzien.
Het product kan de volgende aansluitingen hebben:
Stekeraansluiting volgens ISO 4400 (bij juiste montage wordt
de dichtheidsklasse IP 65 verkregen).
Aansluiting in het metalen huis d.m.v. schroefaansluiting.
De kabeldoorvoer heeft een “PG” aansluiting.
Losse of aangegoten kabels.
IN GEBRUIK STELLEN
Voordat de druk aangesloten wordt dient een elektrische test
te worden uitgevoerd. lngeval van magneetafsluiters legt men
meerdere malen spanning op de spoel aan waarbij een duidelijk
“klikken” hoorbaar moet zijn bij juist functioneren.
GEBRUIK
De meeste magneetafsluiters zijn uitgevoerd met spoelen voor
continu gebruik. Om persoonlijk letsel en schade door aanraking
van het spoelhuis te voorkomen dient men het aanraken te vermij-
den, omdat bij langdurige inschakeling de spoel of het spoelhuis
heet kan worden. In voorkomende gevallen dient men de spoel af
te schermen voor aanraking.
GELUIDSEMISSIE
Dit hangt sterk af van de toepassing en het gebruikte medium.
De bepaling van het geluidsniveau kan pas uitgevoerd worden
nadat de afsluiter is ingebouwd.
ONDERHOUD
Het onderhoud aan de afsluiters is afhankelijk van de bedrijfs-om-
standigheden. We raden u aan om het product regelmatig te
reinigen, in intervallen die afhankelijk zijn van het medium en
de mate van onderhoud. Controleer tijdens het onderhoud of
onderdelen zijn versleten. In geval van slijtage zijn reserveonder-
delensets beschikbaar om een inwendige revisie uit te voeren.
lngeval problemen of onduidelijkheden tijdens montage, gebruik
of onderhoud optreden dan dient men zich tot ASCO Numatics of
haar vertegenwoordiger te wenden.
DEMONTAGE
Neem de afsluiter op een ordelijke wijze uit elkaar. Raadpleeg
daarbij de montagetekeningen die de afzonderlijke onderdelen
benoemen.
1. Verwijder de bevestigingsclip en de spoel. LET OP: bij het
verwijderen van de bevestigingsclip kan deze omhoog springen.
Verwijder daarna de veerring.
2. Schroef de kopstuk/deksel-combinatie los en verwijder diens
O-ring.
3. Verwijder de plunjer, de plunjergeleiding en de plunjerveer.
4. Alle delen zijn nu toegankelijk voor reiniging of vervanging.
MONTAGE
Monteer alle delen in omgekeerde volgorde als aangegeven is bij
demontage, let daarbij wel op de montagetekening voor de juiste
plaatsing van de onderdelen.
1. OPMERKING: Vet alle afdichtingen/O-ringen in met
hoog-waardig siliconenvet.
2. Monteer de plunjerveer, de plunjer en de plunjergeleiding.
3. Monteer de O-ring van de kopstuk/deksel-combinatie, en draai
de kopstuk/deksel-combinatie met het juiste aandraai-moment
vast.
4. Monteer nu de veerring, de spoel en de bevestigingsclip.
5. Na het onderhoud dient men de afsluiter een aantal malen te
bedienen om de werking ervan te controleren.
Ga voor meer informatie naar onze website: www.asco.com
1. Retaining clip
2. Coil & nameplate
3. Connector assembly
4. Spring washer
5. Solenoid base sub-as-
sembly
6. O-ring, solenoid base
sub-assembly
7. Core guide
8. Core assembly
9. Spring, core
10. Valve body
1. Clip de maintien
2. Bobine & fiche signalétique
3. Montage du connecteur
4. Rondelle élastique
5. Sous-ensemble de base
de la tête magnétique
6. Joint torique, sous-en-
semble de base de la tête
magnétique
7. Glissoir du noyau
8. Noyau
9. Ressort, noyau
10. Corps
1. Klammerhalterung
2. Spule & Typenschild
3. Gerätesteckdose
4. Federscheibe
5. Haltemutter
6. Dichtungsring,
7. Haltemutter
8. Ankerführung
9. Magnetankerbaugruppe
10. Feder, Magnetanker
11. Ventilgehäuse
1. Clip de sujeción
2. Bobina y placa de carac-
terísticas
3. Conjunto del conector
4. Arandela resorte
5. Base auxiliar del
solenoide
6. Junta, base auxiliar del
solenoide
7. Guía del núcleo
8. Conjunto del núcleo
9. Resorte, núcleo
10. Cuerpo de la válvula
1. Clip di fissaggio
2. Bobina e targhetta
3. Gruppo connettore
4. Rondella elastica
5. Sottogruppo di base del
solenoide
6. Anello di ritenuta, sotto-
gruppo di base del
solenoide
7. Cannotto
8. Gruppo del nucleo
9. Molla, nucleo
10. Corpo valvola
1. Clip
2. Spoel met typeplaatje
3. Steker
4. Veerring
5. Kopstuk/deksel-combinatie
6. O-ring, kopstuk/dek-
sel-combinatie
7. Plunjergeleiding
8. Plunjer
9. Plunjerveer
10. Afsluiterhuis
ISTRUZIONI DI INSTALLAZIONE E MANUTENZIONE
a comando diretto
1/4
ALGEMENE INSTALLATIE- EN ONDERHOUDSINSTRUCTIES
direct werkend
1/4
1*
2
3
4*
5
6*
7*
8*
9*
10
17
ø32
M4 x 8
B
A
1
1
23
1
23
2

Transcripción de documentos

1 INSTALLATION AND MAINTENANCE INSTRUCTIONS direct operated 1/4 DESCRIPTION Series 314 are direct operated 3/2 solenoid valves. The solenoid valves have normally closed operation, air only - with an exhaust to atmosphere on top of the solenoid. The valve body is brass construction. INSTALLATION ASCO Numatics components are intended to be used only within the technical characteristics as specified on the nameplate. Changes to the equipment are only allowed after consulting the manufacturer or its representative. Before installation depressurise the piping system and clean internally. The equipment may be mounted in any position. Connect piping to valve according to markings on valve body. The pipe connections have to be in accordance with the size indicated on the nameplate and fitted accordingly. Caution: • Reducing the connections may cause improper operation or malfunctioning. • For the protection of the equipment install a strainer or filter suitable for the service involved in the inlet side as close to the product as possible. • If tape, paste, spray or a similar lubricant is used when tightening, avoid particles entering the system. • Use proper tools and locate wrenches as close as possible to the connection point. • To avoid damage to the equipment, DO NOT OVERTIGHTEN pipe connections. • Do not use valve or solenoid as a lever. • The pipe connections should not apply any force, torque or strain to the product. ELECTRICAL CONNECTION In case of electrical connections, they are only to be made by trained personnel and have to be in accordance with the local regulations and standards. Caution: • Turn off electrical power supply and de-energise the electrical circuit and voltage carrying parts before starting work. • All electrical screw terminals must be properly tightened according to the standards before putting into service. • Dependent upon the voltage electrical components must be provided with an earth connection and satisfy local regulations and standards. VALVE DISASSEMBLY Disassemble in an orderly fashion. Pay careful attention to exploded views provided for identification of parts. 1. Remove retaining clip and coil. CAUTION: when metal retaining clip disengages, it can spring upwards. Then remove the spring washer. 2. Unscrew the solenoid base sub-assembly and remove its O-ring. 3. Remove the core assembly, core guide and core spring. 4. All parts are now accessible for cleaning or replacement. VALVE REASSEMBLY Reassemble in reverse order of disassembly paying careful attention to exploded views provided for identification and placement of parts. 1. NOTE: Lubricate all gaskets/O-rings with high quality silicone grease. 2. Replace core spring, core assembly, and core guide. 3. Replace solenoid base sub-assembly O-ring and torque solenoid base sub-assembly according to torque chart. 4. Replace spring washer, coil and retaining clip. 5. After maintenance, operate the valve a few times to be sure of proper operation. For additional information visit our website: www.asco.com BETRIEBSANLEITUNG Magnetventil direkt betätigt 1/4 ELEKTRISCHER ANSCHLUSS Der elektrische Anschluß ist von Fachpersonal entsprechend den geltenden VDE- und CEE-Bestimmungen auszuführen. Vorsicht: • Vor Beginn der Arbeiten ist sicherzustellen, daß alle elektrischen Leitungen und Netzteile spannungslos geschaltet sind. • Alle Anschlußklemmen sind nach Beendigung der Arbeiten vorschriftsmäßig entsprechend den geltenden Normen anzuziehen. • Je nach Spannungsbereich muß das Ventil nach den geltenden Bestimmungen und Normen einen Schutzleiter-anschluß erhalten. Der Magnetantrieb kann je nach Bauart folgende elektrische Anschlüsse aufweisen • Flachsteckeranschlüsse gemäß ISO 4400 (bei ordnungsgemäßer Montage ist Schutzart IP-65 gewährleistet). • Anschlüsse innerhalb eines Metallgehäuses mittels Schraubklemmen. Kabeleinführung ins Gehäuse mit PG- Verschraubung. • Eingegossene Kabelenden. INBETRIEBNAHME Vor Druckbeaufaufschlagung des Produktes sollte eine elektrische Funktionsprüfung erfolgen: Bei Magnetventilen Spannung an der Magnetspule mehrmals ein- und ausschalten. Es muß ein metallisches Klicken zu hören sein. 123620-658 (535-03) Page 1 of 2 DEMONTAGE DE LA VANNE Démonter de façon méthodique. sur les vues en éclaté fournies dans la pochette et destinées à l’identification des pièces. 1. Ôtez le clip de maintien et la bobine. ATTENTION: lorsque le clip de maintien métallique est ôté, il peut bondir vers le haut. Puis ôter la rondelle élastique. 2. Dévisser le sous-ensemble de base de la tête magnétique et ôter son joint torique. 3. Ôter le montage du noyau, le glissoir du noyau et le ressort du noyau. 4. Vous pouvez dès à présent nettoyer ou remplacer toutes les pièces. REMONTAGE DE LA VANNE Remonter en sens inverse. 1. NOTE: Lubrifier tous les joints d’étanchéité/joints toriques avec de la graisse silicone de haute qualité. 2. Replacer le ressort du noyau, le montage du noyau et le glissoir du noyau. 3. Replacer le joint torique du sous-ensemble de base de la tête magnétique et raccorder le sous-ensemble de base de la tête magnétique selon le schéma de couple. 4. Replacer la rondelle élastique du ressort, la bobine et le clip de maintien. 5. Après l’entretien, faire fonctionner la vanne quelques fois afin de s’assurer qu’elle s’ouvre et se ferme correctement. Pour toute information complémentaire, veuillez consulter notre site Web: www.asco.com FONCTIONNEMENT La plupart des électrovannes comportent des bobinages prévus pour mise sous tension permanente. Pour éviter toute brûlure, ne pas toucher la tête magnétique qui, en fonctionnement normal et en permanence sous tension, peut atteindre une température élevée. Si l’électrovanne est facilement accessible, l’installateur doit prévoir une protection empêchant tout contact accidentel. SOUND EMISSION The emission of sound depends on the application, medium and nature of the equipment used. The exact determination of the sound level can only be carried out by the user having the valve installed in his system. Die Rohrleitungsanschlüsse sollten entsprechend den Größenangaben auf den Typenschildern mit handelsüblichen Verschraubungen durchgeführt werden. Vorsicht: • Eine Reduzierung der Anschlüsse kann zu Leistungs- und Funktionsminderungen führen. • Zum Schutz der Ventile sollten für die Betriebsbedingungen geeignete Schmutzfänger oder Filter so dicht wie möglich in den Ventileingang integriert werden. • Bei Abdichtung am Gewinde ist darauf zu achten, daß kein Dichtungsmaterial in die Rohrleitung oder das Ventil gelangt. • Zum Einbau darf nur geeignetes Werkzeug verwendet werden, das so nahe wie möglich am Anschlußpunkt anzusetzen ist. • Um eine Beschädigung der Produkte zu vermeiden, ist darauf zu achten, daß die Rohranschlüsse NICHT ZU STARK ANGEZOGEN werden. • Spule und Führungsrohr von Ventilen dürfen nicht als Gegenhalter benutzt werden. • Die Rohrleitungsanschlüsse sollten fluchten und dürfen keine Spannungen auf das Ventil übertragen. La dimension des tuyauteries doit correspondre au raccordement indiqué sur le corps, l’étiquette ou la notice. Attention: • Une restriction des tuyauteries peut entraîner des dysfonc-tionnements. • Afin de protéger le matériel, installer une crépine ou un filtre adéquat en amont, aussi près que possible du produit. • En cas d’utilisation de ruban, pâte, aérosol ou un lubrifiant lors du serrage, veillez à ce qu’aucun corps étranger ne pénétre dans le circuit. • Utiliser un outillage approprié et placer les clés aussi près que possible du point de raccordement. • Afin d’éviter toute détérioration, NE PAS TROP SERRER les raccords des tuyauteries. • Ne pas se servir de la vanne ou de la tête magnétique comme d’un levier. • Les tubes de raccordement ne devront exercer aucun effort, couple ou contrainte sur le produit. ENTRETIEN L’entretien nécessaire aux produits ASCO Numatics varie avec leurs conditions d’utilisation. Il est souhaitable de procéder à un nettoyage périodique dont l’intervalle varie suivant la nature du fluide, les conditions de fonctionnement et le milieu ambiant. Lors de l’intervention, les composants doivent être examinés pour détecter toute usure excessive. Un ensemble de pièces internes est proposé en pièces de rechange pour procéder à la réfection. En cas de problème lors du montage/entretien ou en cas de doute, veuillez contacter ASCO Numatics ou ses représentants officiels. MISE EN SERVICE Avant de mettre le circuit sous pression, effectuer un essai électrique. Dans le cas d’une électrovanne, mettre la bobine sous tension plusieurs fois et écouter le “clic” métallique qui signale le fonctionnement de la tête magnétique. SERVICE Most of the solenoid valves are equipped with coils for continuous duty service. To prevent the possibility of personal or property damage do not touch the solenoid which can become hot under normal operation conditions. If the solenoid valve is easily accessible, the installer must provide protection preventing accidental contact. EINBAU Die ASCO Numatics-Komponenten dürfen nur innerhalb der auf den Typenschildern angegebenen Daten eingesetzt werden. Veränderungen an den Produkten sind nur nach Rücksprache mit ASCO Numatics zulässig. Vor dem Einbau der Ventile muß das Rohrleitungssystem drucklos geschaltet und innen gereinigt werden. Die Einbaulage der Produkte ist generell beliebig. Leitungen entsprechend den Markierungen am Ventilgehäuse mit dem Ventil verbinden. MONTAGE Les composants ASCO Numatics sont conçus pour les domaines de fonctionnement indiqués sur la plaque signal-étique ou la documentation. Aucune modification ne peut être réalisée sur le matériel sans l’accord préalable du fabricant ou de son représentant. Avant de procéder au montage, dépressuriser les canalisations et effectuer un nettoyage interne. Les électrovannes peuvent être monté dans n’importe quelle position. Connecter la canalisation à l’électrovanne selon les indications indiquées sur le corps de l’électrovanne. FR 3 2 BRUIT DE FONCTIONNEMENT Le bruit de fonctionnement varie selon l’utilisation, le fluide et le type de matériel employé. L’utilisateur ne pourra déterminer avec précision le niveau sonore émis qu’après avoir monté le composant sur l’installation. Selon les cas, le raccordement électrique s’effectue par: • Connecteur débrochable ISO 4400 avec degré de protection IP-65 lorsque le raccordement est correctement effectué. • Bornes à vis solidaires du bobinage, sous boîtier métallique avec presse-étoupe étanche “Pg”. • Fils ou câbles solidaires de la bobine. PUTTING INTO SERVICE Before pressurising the system, first carry-out an electrical test. In case of solenoid valves, energise the coil a few times and notice a metal click signifying the solenoid operation. BESCHREIBUNG Bei der Baureihe 314 handelt es sich um direkt betätigte 3/2-Magnetventile. Die Magnetventile sind für normal geschlossenen Betrieb und ausschließlich für Luft geeignet und besitzen eine Entlüftung zur Atmosphäre an der Oberseite des Magnetkopfs. Das Ventilgehäuse besteht aus Messing. DESCRIPTION Les vannes de la série 314 font partie de la gamme des électrovannes 3/2 à commande directe. Les électrovannes fonctionnent normalement fermées, uniquement à air - elles sont équipées d’un échappement dans l’atmosphère situé au-dessus de l’électrovanne. Le corps est en laiton. RACCORDEMENT ÉLECTRIQUE Le raccordement électrique doit être réalisé par un personnel qualifié et selon les normes et règlements locaux. Attention: • Avant toute intervention, couper l’alimentation électrique pour mettre hors tension les composants. • Toutes les bornes à vis doivent être serrées correctement avant la mise en service. • Selon la tension, les composants électriques doivent être mis à la terre conformément aux normes et règlements locaux. The equipment can have one of the following electrical terminals: • Spade plug connections according to ISO 4400 (when correctly installed this connection provides lP-65 protection). • Embedded screw terminals in metal enclosure with “Pg” cable gland. • Flying leads or cables. 1 INSTRUCTIONS D’INSTALLATION ET D’ENTRETIEN à commande directe 1/4 GB 3 2 MAINTENANCE Maintenance of ASCO Numatics products is dependent on service conditions. Periodic cleaning is recommended, the timing of which will depend on the media and service conditions. During servicing, components should be examined for excessive wear. A complete set of internal parts is available as a spare parts kit. If a problem occurs during installation/maintenance or in case of doubt please contact ASCO Numatics or authorised representatives. 1 3 2 INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO accionada directamente 1/4 DE BETRIEB Die meisten Magnetventile sind mit Spulen für Dauerbetrieb ausgerüstet. Zur Vermeidung von Personen- und Sachschäden sollte jede Berührung der Magnetspule vermieden werden, da diese unter normalen Betriebsbedingungen sehr heiß werden kann. Bei leicht zugänglichem Magnetventil sollte vom Installateur ein Schutz vorgesehen werden, um jegliches versehentliches Berühren zu vermeiden. GERÄUSCHEMISSION Die Geräuschemission hängt sehr stark vom Anwendungsfall, dem Medium, mit denen das Produkt beaufschlagt wird, und der Art des verwendeten Produktes ab. Die exakte Bestimmung des Geräuschpegels kann aus diesem Grund nur durch die Person durchgeführt werden, die das Ventil in das jeweilige System eingebaut hat. WARTUNG Die Wartung hängt von den Betriebsbedingungen ab. Es wird empfohlen, das Produkt regelmäßig zu reinigen, wobei sich die Zeitabstände nach dem Medium und den Betriebsbedingungen richten. Während der Wartung sollten die Komponenten auf übermäßigen Verschleiß überprüft werden. Für die Überholung der ASCO Numatics-Produkte sind komplette Sätze mit internen Teilen als Ersatzteilsätze erhältlich. Treten Schwierigkeiten bei Einbau, Betrieb oder Wartung auf sowie bei Unklarheiten, ist mit ASCO Numatics Rücksprache zu halten. VENTILDEMONTAGE Das Ventil muß in der angegebenen Reihenfolge zerlegt werden. Dabei sind die Teile exakt anhand der mitgelieferten Explosionszeichnungen zu identifizieren. 1. Halteklammer und Spule entfernen. ACHTUNG: Die Klammerhalterung kann beim Lösen nach oben wegfedern. Dann Federscheibe entfernen. 2. Haltemutter lösen und zugehörigen Dichtungsring ausbauen. 3. Magnetankerbaugruppe, Führungsrohr und Magnetankerfeder entfernen. 4. Nun sind alle Teile, die gereinigt oder ausgetauscht werden müssen, leicht zugänglich. VENTILZUSAMMENBAU Ventil in der umgekehrten Reihenfolge wie bei der Demontage zusammenbauen. Dabei sind die Teile anhand der Explosionszeichnungen zu identifizieren und anzuordnen. 1. HINWEIS: Alle Dichtungen/Dichtungsringe sind mit hochwertigem Silikonfett zu schmieren. 2. Magnetankerfeder, Magnetankerbaugruppe und Führungsrohr wieder montieren. 3. Haltemutter-Dichtungsring wieder montieren und Haltemutter entsprechend den Angaben im Drehmomentdiagramm anziehen. 4. Federscheibe, Spule und Halteklammer wieder anbringen. 5. Nach der Wartung Ventil mehrmals betätigen, um sicherzustellen, daß es ordnungsgemäß funktioniert. Weitere Informationen finden Sie auf unserer Website: www.asco.com DESCRIPCION La Serie 314 está formada por válvulas de solenoide de 3/2 de accionamiento directo. Las válvulas de solenoide son de funcionamiento normalmente cerrado, sólo de aire; con escape a la atmósfera en la parte superior del solenoide. El cuerpo de la válvula está construido de latón. INSTALACION Los componentes ASCO Numatics sólo deben utilizarse dentro de las especificaciones técnicas que se especifican en su placa de características. Los cambios en el equipo sólo estarán permitidos después de consultar al fabricante o a su representante. Antes de la instalación, despresurice el sistema de tuberías y limpie internamente. El equipo puede utilizarse en cualquier posición. Conecte la tubería a la válvula según las marcas que se encuentran en el cuerpo de la válvula. Las conexiones a la tubería deben corresponder al tamaño indi-cado en la placa de características y ajustarse adecuadamente. Precaución: • La reducción de las conexiones puede causar operaciones incorrectas o defectos de funcionamiento. • Para la protección del equipo se debe instalar en la parte de la entrada y tan cerca como sea posible del producto un filtro o tamizador adecuado para el servicio. • Si se utilizara cinta, pasta, spray u otros lubricantes en el ajuste, se debe evitar que entren partículas en el producto. • Se debe utilizar las herramientas adecuadas y colocar llaves lo más cerca posible del punto de conexión. • Para evitar daños al equipo, NO FORZAR las conexiones a la tubería. • No utilizar la válvula o el solenoide como palanca. • Las conexiones a la tubería no producirán ninguna fuerza, apriete o tensión sobre el producto. CONEXION ELECTRICA En caso de requerirse conexiones eléctricas, estas serán realizadas por personal cualificado y deberán adaptarse a las normas y regulaciones locales. Precaución: • Antes de comenzar el trabajo, desconecte el suministro de energía eléctrica y desenergice el circuito electrónico y los elementos portadores de tensión. • Todos los terminales eléctricos deben estar apretados ade-cuadamente según normas antes de su puesta en servicio. • Según el voltaje, los componentes electrónicos deben disponer de una conexión a tierra y satisfacer las normas y regulaciones locales. 1 3 2 ES EMISION DE RUIDOS La emisión de ruidos depende de la aplicación, medio y naturaleza del equipo utilizado. Una determinación exacta del nivel de ruido solamente se puede llevar a cabo por el usuario que disponga la válvula instalada en su sistema. MANTENIMIENTO El mantenimiento de los productos ASCO Numatics depende de las condiciones de servicio. Se recomienda una limpieza periódica, dependiendo de las condiciones del medio y del servicio. Durante el servicio, los componentes deben ser examinados por si hubiera desgastes excesivos. Se dispone de un juego completo de partes internas como recambio. Si ocurriera un problema durante la instalación/mantenimiento o en caso de duda contactar con ASCO Numatics o representantes autorizados. DESMONTAJE DE LA VALVULA Desmonte la válvula ordenadamente. Preste especial atención a las vistas ampliadas que se suministran para identificar las partes. 1. Retire el clip de sujeción y la bobina. PRECAUCION: al desengancharse el clip de sujeción metálico, éste puede saltar hacia arriba. A continuación retire la arandela resorte. 2. Desatornille el conjunto de la base auxiliar del solenoide y retire su junta. 3. Retire el conjunto del núcleo, la guía del núcleo y el resorte del núcleo. 4. Ahora tendrá acceso a todas las piezas para su limpieza o sustitución. REMONTAJE DE LA VALVULA Vuelva a montar la válvula en el orden inverso de desmontaje prestando especial atención a las vistas ampliadas suministradas para identificar e instalar las partes. 1. NOTA: Lubrique todas las guarniciones/juntas con grasa de silicona de buena calidad. 2. Vuelva a colocar el resorte del núcleo, el conjunto del núcleo y la guía del núcleo. 3. Vuelva a colocar la arandela del conjunto de la base auxiliar del solenoide y apriete el conjunto auxiliar de la base del solenoide según el cuadro de apriete. 4. Vuelva a colocar la arandela resorte, la bobina y el clip de sujeción. 5. Después de realizado el mantenimiento, opere la válvula unas cuantas veces para asegurarse de su correcto funcionamiento. Para obtener información adicional, visite nuestro sitio Web: www.asco.com El equipo puede tener uno de los siguientes terminales eléctricos: • Conexiones desenchufables según ISO 4400 (cuando se instala correctamente, esta conexión proporciona la protección IP-65). • Terminales de tornillo con carcasa metálica con entrada de cable de conexión roscada «PG». • Salida de cables. PUESTA EN MARCHA Se debe efectuar una prueba eléctrica antes de someter a presión el sistema. En el caso de las válvulas solenoides, se debe energizar varias veces la bobina y comprobar que se produce un sonido metálico que indica el funcionamiento del solenoide. SERVICIO La mayor parte de las válvulas solenoides se suministran con bobinas para un servicio continuo. Con el fin de evitar la posibilidad de daños personales o materiales no se debe tocar el solenoide, ya que puede haberse calentado en condiciones normales de trabajo. Si la electroválvula es de fácil acceso, el instalador debe prever una protección que impida cualquier contacto accidental. www.asco.com Modified on: 2017-10-03 1 ISTRUZIONI DI INSTALLAZIONE E MANUTENZIONE a comando diretto 1/4 DESCRIZIONE La Serie 314 comprende elettrovalvole a comando diretto a 3 vie. Le elettrovalvole sono in versione normalmente chiusa, solo aria - con scarico in atmosfera sul solenoide. Il corpo è in ottone. INSTALLAZIONE Le elettrovalvole ASCO Numatics devono essere utilizzate esclusivamente rispettando le caratteristiche tecniche specificate sulla targhetta. Variazioni sulle elettrovalvole sono ammissibili solo dopo avere consultato il costruttore o il suo rappresentante. Prima dell’installazione, depressurizzare i tubi e pulire internamente. Le elettrovalvole possono essere montate in tutte le posizioni. Collegare i tubi alla valvola seguendo le marcature sul corpo della valvola. I raccordi devono essere conformi alla misura indicata sull’ apposita targhetta. Attenzione: • Ridurre i raccordi può causare operazioni sbagliate o malfunzionamento. • Per proteggere il componente installare, il più vicino possibile al lato ingresso, un filtro adatto al servizio. • Se si usano nastro, pasta spray o lubrificanti simili durante il serraggio, evitare che delle particelle entrino nel corpo della valvola. • Usare attrezzature appropriate e posizionare le chiavi il più vicino possibile al punto di raccordo. • Per evitare danni al corpo della valvola, NON SERRARE ECCESSIVAMENTE i raccordi. • Non usare la valvola o il solenoide come una leva. • I raccordi non devono esercitare pressione, torsione o sollecitazione sull’ elettrovalvola. ALLACCIAMENTO ELETTRICO L’allacciamento elettrico deve essere effettuato esclusivamente da personale specializzato e deve essere conforme alle norme locali. Attenzione: • Prima di mettere in funzione, togliere l’alimentazione elettrica, diseccitare il circuito elettrico e le parti sotto tensione. • I morsetti elettrici devono essere correttamente avvitati secondo le norme prima della messa in servizio. • Le elettrovalvole devono essere provviste di morsetti di terra a seconda della tensione e delle norme di sicurezza locali. 3 MANUTENZIONE Generalmente questi componenti non necessitano spesso di manutenzione. Comunque in alcuni casi è necessario fare attenzione a depositi o ad eccessiva usura. Questi componenti devono essere puliti periodicamente. Il tempo che intercorre tra una pulizia e l’altra varia a seconda delle condizioni di funzionamento. Il ciclo di durata dei componenti dipende dalle condizioni di funzionamento. In caso di usura è disponibile un set completo di parti interne per la revisione. Se si incontrano problemi durante l’installazione e la manutenzione o se si hanno dei dubbi, consultare ASCO Numatics o i suoi rappresentanti. SMONTAGGIO VALVOLE Smontare procedendo con ordine. Consultare attentamente gli esplosi forniti per una corretta identificazione delle parti. 1. Smontare la clip di fissaggio e la bobina. ATTENZIONE: Quando si sgancia la clip metallica di fissaggio, può scattare verso l’alto. Poi smontare la ghiera. 2. Svitare il sottogruppo di base del solenoide e smontare l’anello di ritenuta. 3. Smontare il gruppo del nucleo, il guida-nucleo e la molla del nucleo. 4. Ora tutte le parti sono accessibili per la pulizia o la sostituzione. RIMONTAGGIO VALVOLA Rimontare procedendo nell’ordine inverso facendo riferimento agli esplosi forniti per la corretta identificazione e collocazione delle parti. 1. NOTA: Lubrificare tutte le guarnizioni/anelli di tenuta con grasso al silicone d’alta qualità. 2. Rimontare la molla del nucleo, il gruppo del nucleo e il guida nucleo. 3. Rimontare l’anello di ritenuta del sottogruppo di base del solenoide e serrare il sottogruppo di base del solenoide secondo la tabella delle coppie. 4. Rimontare la ghiera, la bobina e la clip di fissaggio. 5. Dopo la manutenzione, azionare ripetutamente la valvola per accertarne il corretto funzionamento. Per informazioni aggiuntive, visitate il nostro sito web: www.asco.com I piloti possono avere una delle seguenti caratteristiche elettriche: • Connettori a spada secondo ISO 4400 (se correttamente installata, questa connessione fornisce protezione IP-65). • Morsettiera racchiusa in custodia metallica. Entrata cavi con pressacavi tipo “Pg”. • Bobine con fili o cavo. NL GELUIDSEMISSIE Dit hangt sterk af van de toepassing en het gebruikte medium. De bepaling van het geluidsniveau kan pas uitgevoerd worden nadat de afsluiter is ingebouwd. BESCHRIJVING Afsluiters uit de 314-serie zijn direct werkende 3/2-magneetafsluiters. De magneetafsluiters zijn geschikt voor normaal gesloten gebruik, met uitsluitend lucht - en zijn voorzien van een afvoer naar de atmosfeer bovenop de magneetkop. Het afsluiterhuis is van messing. ONDERHOUD Het onderhoud aan de afsluiters is afhankelijk van de bedrijfs-omstandigheden. We raden u aan om het product regelmatig te reinigen, in intervallen die afhankelijk zijn van het medium en de mate van onderhoud. Controleer tijdens het onderhoud of onderdelen zijn versleten. In geval van slijtage zijn reserveonderdelensets beschikbaar om een inwendige revisie uit te voeren. lngeval problemen of onduidelijkheden tijdens montage, gebruik of onderhoud optreden dan dient men zich tot ASCO Numatics of haar vertegenwoordiger te wenden. INSTALLATIE ASCO Numatics producten mogen uitsluitend toegepast worden binnen de op de naamplaat aangegeven specificaties. Wijzigingen zijn alleen toegestaan na overleg met de fabrikant of haar vertegenwoordiger. Voor het inbouwen dient het leidingsysteem drukloos gemaakt te worden en inwendig gereinigd. De positie van de afsluiter is naar keuze te bepalen. Kijk naar de markeringen op het huis voor het aansluiten van de aan- en afvoerleidingen op de afsluiter. DEMONTAGE Neem de afsluiter op een ordelijke wijze uit elkaar. Raadpleeg daarbij de montagetekeningen die de afzonderlijke onderdelen benoemen. 1. Verwijder de bevestigingsclip en de spoel. LET OP: bij het verwijderen van de bevestigingsclip kan deze omhoog springen. Verwijder daarna de veerring. 2. Schroef de kopstuk/deksel-combinatie los en verwijder diens O-ring. 3. Verwijder de plunjer, de plunjergeleiding en de plunjerveer. 4. Alle delen zijn nu toegankelijk voor reiniging of vervanging. De pijpaansluiting moet overeenkomstig de naamplaatgegevens plaatsvinden. Let op: • Een reductie van de aansluitingen kan tot prestatie en functiestoornis leiden. • Ter bescherming van de interne delen wordt een filter in het leidingnet aanbevolen. • Bij het gebruik van draadafdichtingspasta of tape mogen er geen deeltjes in het leidingwerk geraken. • Men dient uitsluitend geschikt gereedschap voor de montage te gebruiken. • Gebruik een zodanig koppel voor leidingverbindingen dat het product NIET WORDT BESCHADIGD. • Het product, de behuizing of de spoel mag niet als hefboom worden gebruikt. • De pijpaansluitingen mogen geen krachten of momenten op het product overdragen. MONTAGE Monteer alle delen in omgekeerde volgorde als aangegeven is bij demontage, let daarbij wel op de montagetekening voor de juiste plaatsing van de onderdelen. 1. OPMERKING: Vet alle afdichtingen/O-ringen in met hoog-waardig siliconenvet. 2. Monteer de plunjerveer, de plunjer en de plunjergeleiding. 3. Monteer de O-ring van de kopstuk/deksel-combinatie, en draai de kopstuk/deksel-combinatie met het juiste aandraai-moment vast. 4. Monteer nu de veerring, de spoel en de bevestigingsclip. 5. Na het onderhoud dient men de afsluiter een aantal malen te bedienen om de werking ervan te controleren. ELEKTRISCHE AANSLUITING In geval van elektrische aansluiting dient dit door vakkundig personeel te worden uitgevoerd volgens de door de plaatselijke overheid bepaalde richtlijnen. Let op: • Voordat men aan het werk begint moeten alle spannings-voerende delen spanningsloos worden gemaakt. • Alle aansluitklemmen moeten na het beëindigen van het werk volgens de juiste normen worden aangedraaid. • Al naar gelang het spanningsbereik moet het product volgens de geldende normen van een aarding worden voorzien. Ga voor meer informatie naar onze website: www.asco.com GEBRUIK De meeste magneetafsluiters zijn uitgevoerd met spoelen voor continu gebruik. Om persoonlijk letsel en schade door aanraking van het spoelhuis te voorkomen dient men het aanraken te vermijden, omdat bij langdurige inschakeling de spoel of het spoelhuis heet kan worden. In voorkomende gevallen dient men de spoel af te schermen voor aanraking. EMISSIONE SUONI L’emissione di suoni dipende dall’applicazione e dal tipo di elettrovalvola. L’utente può stabilire esattamente il livello del suono solo dopo aver installato la valvola sul suo impianto. DESSIN DIBUJO ZEICHNUNG TEKENING DRAWING DISEGNO DESSIN DIBUJO ZEICHNUNG TEKENING GB SERIES 314 DESCRIPTION 2 Retaining clip Coil & nameplate Connector assembly Spring washer Solenoid base sub-assembly 6. O-ring, solenoid base sub-assembly 3 1. 2. 3. 4. 5. 1* 1. 2. 3. 4. 5. FR 2 1 DE 1. 2. 3. 4. 5. 6. 7. 8. 5 B 6* GB ¬ Supplied in spare part kit 7* DE ¬ Enthalten im Ersatzteilsatz FR ¬ Livrées en pochette de rechange ES ¬ Incluido en Kit de recambio IT 8* ¬ Disponibile nel Kit parti di ricambio NL ¬ Geleverd in vervangingsset 9* M4 x 8 A 0,6±0,2 5±2 B 20±3 175±25 ITEMS NEWTON.METRES INCH.POUNDS TORQUE CHART 17 ø32 Ø 1/4 Catalogue number Code électrovanne Katalognummer Código de la electrovalvula Codice elettrovalvola Katalogus nummer SCB 314C22 SCB 314C23 SCB 314C24 www.asco.com Spare part kit Code pochette de rechange Ersatzteilsatz Código del kit de recambio Kit parti di ricambio Vervangingsset ~ = C302-869 C302-870 C302-871 - 9. Magnetankerbaugruppe 10. Feder, Magnetanker 11. Ventilgehäuse DESCRIPCION 1. Clip de sujeción 2. Bobina y placa de características 3. Conjunto del conector 4. Arandela resorte 5. Base auxiliar del solenoide 6. Junta, base auxiliar del IT 1. 2. 3. 4. 5. solenoide 7. Guía del núcleo 8. Conjunto del núcleo 9. Resorte, núcleo 10. Cuerpo de la válvula DESCRIZIONE Clip di fissaggio Bobina e targhetta Gruppo connettore Rondella elastica Sottogruppo di base del solenoide 6. Anello di ritenuta, sottogruppo di base del NL magnétique 7. Glissoir du noyau 8. Noyau 9. Ressort, noyau 10. Corps BESCHREIBUNG Klammerhalterung Spule & Typenschild Gerätesteckdose Federscheibe Haltemutter Dichtungsring, Haltemutter Ankerführung ES 7. Core guide 8. Core assembly 9. Spring, core 10. Valve body DESCRIPTION Clip de maintien Bobine & fiche signalétique Montage du connecteur Rondelle élastique Sous-ensemble de base de la tête magnétique 6. Joint torique, sous-ensemble de base de la tête A 4* 123620-658 (535-03) Page 2 of 2 2 IN GEBRUIK STELLEN Voordat de druk aangesloten wordt dient een elektrische test te worden uitgevoerd. lngeval van magneetafsluiters legt men meerdere malen spanning op de spoel aan waarbij een duidelijk “klikken” hoorbaar moet zijn bij juist functioneren. SERVIZIO Molte elettrovalvole sono provviste di bobine per il funzionamento continuo. Per prevenire la possibilità di danneggiare cose o persone, non toccare il solenoide. Se di facile accesso, l’elettrovalvola deve essere protetta per evitare qualsiasi contatto accidentale. 10 1 3 Het product kan de volgende aansluitingen hebben: • Stekeraansluiting volgens ISO 4400 (bij juiste montage wordt de dichtheidsklasse IP 65 verkregen). • Aansluiting in het metalen huis d.m.v. schroefaansluiting. De kabeldoorvoer heeft een “PG” aansluiting. • Losse of aangegoten kabels. MESSA IN FUNZIONE Prima di dare pressione alla valvola, eseguire un test elettrico. Eccitare la bobina diverse volte fino a notare uno scatto metallico che dimostra il funzionamento del solenoide. DRAWING DISEGNO ALGEMENE INSTALLATIE- EN ONDERHOUDSINSTRUCTIES direct werkend 1/4 IT 2 solenoide 7. Cannotto 8. Gruppo del nucleo 9. Molla, nucleo 10. Corpo valvola BESCHRIJVING 1. 2. 3. 4. 5. 6. Clip 8. Plunjer Spoel met typeplaatje 9. Plunjerveer Steker 10. Afsluiterhuis Veerring Kopstuk/deksel-combinatie O-ring, kopstuk/deksel-combinatie 7. Plunjergeleiding Modified on: 2017-10-03
  • Page 1 1
  • Page 2 2

Asco Series 314 Solenoid Valve Exhaust to Atmosphere Manual de usuario

Tipo
Manual de usuario