Haier 3U19FS1ERA Guía de instalación

Categoría
Acondicionadores de aire de sistema dividido
Tipo
Guía de instalación

Este manual también es adecuado para

INSTALLATION MANUAL
MULTI-SPLIT AIR CONDITIONER
Please read this manual carefully before installation.
Keep this operation manual for future reference.
No. 0150508607 D
INSTALLATION MANUAL
MULTI-SPLIT AIR CONDITIONER
Please read this manual carefully before installation.
Keep this operation manual for future reference.
3
4
4
5
7
7
7
7
12
12
14
15
Contents
English
Safety Precautions
Accessories
Precautions for Selecting the
Location
Installation drawings of indoor and
outdoor units
Precautions on Installation
Outdoor Unit Installation Guideline
Limitations on the installation
Refrigerant piping work
Pump Down Operation
Wiring work
Test running
Trouble shooting
3
Safety Precautions
WARNING
CAUTION
WARNING
CAUTION
Read these Safety Precautions carefully to ensure correct installation.
This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions bellow: they are all important for ensuring safety.
Failure to follow any of WARING is likely to result in such grave consequences as death or serious injury.
Failure to follow any of CAUTION may in some cases result in grave consequences.
The following safety symbols are used throughout this manual:
Be sure to observe this instruction Be sure to establish an earth connection Never attempt
After completing installation, test the unit to check for installation errors. Give the user adequate instructions conceming the use and cleaning
of the unit according to the Operation Manual.
Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
Be sure to use the suplied or specified installation parts.
Use of other parts may cause the unit to cometo lose, water leakage, electrical shock, or fire.
Install the air conditioner on a solid base that can support the unit's weight.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
Electrical work should be carried out in accordance with the installation manual and the national electrical wiring rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
For wiring, use a cable long enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnectiong wires so their terminals terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.
After connectiong interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical
covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
When installing or relocating the system, be sure to keep the refrigerant circuit free from substancs other than the specified
refrigerant(R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the rcompressor is run, causing abnormal pressure in the freezer
cycle which will lead to breakage and even injury.
Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
In complete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks, or fire.
Do not install the aire conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the falre nut may crack after a long time and cause refrigerant leakage.
Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.
4
Accessories
Precautions for Selecting the Location
NOTE:
CAUTION
Construct a large canopy.
Construct a pedestal.
Install the unit high enough off the
ground to prevent burying in snow.
Accessories supplied with the outdoor unit:
1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot aire discharged from the unit or the operation noise, will not cause a nuisance to the neighbors of the
user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient space for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
Locate the unit so that the noise and the discharged hot air will not annoy the neighbors.
7) Install units, power cords and inter-unit cables at least 3 meter away from television and radio sets. This is to prevent interference to
images and sounds. (Noises may be heard even if they are more than 3 meter away depending on radio wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner.
9)Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.
Cannot be installed hanging from ceiling or stacked.
When operationg the air conditioner in a low outdoor ambient
temperature, be sure to follow the instructions described below.
1) To prevent exposure to wind, install the outdoor unit with its suction
side facing the wall.
2) Never install the outdoor unit at a site where the suction side may be
exposed directly to wind.
3)To prevent exposure to wind, it is recommended to install a baffle plate
on the air discharge side of the outdoor unit.
4) In heavy snowfall areas, select an installation site where the snow
will not affect the unit.
5
Installation figure please refers to
1. Do not connected the embedded branch piping and the outdoor unit when only carrying out piping work without connecting the indoor
unit in ordor to add another indoor unit later. Make sure no dirt or mositure gets into eigher side of the embedded branch piping.
2.It is impossible to connect the indoor unit for one room only.
Installation drawings of indoor and outdoor units
If there is the danger of the unit falling or overturning, fix the unit with foundation bolts, or with wire or other means.
If the location does not have good drainage, place the unit on a level mounting base(or a plastic pedestal).
Install the outdoor unit in a level position. Failure to do so may result in water leakage or accumulation.
Arrangement of piping directions
Rear left
Rear right
Right
Below
Left
Wrap the insulation pipe with the finishing tape
from bottom to top.
Cut thermal insulation pipe to an appropriate
length and wrap it with tape, making sure that no
gap is left in the insulation pipe's cut line.
more than 10cm
more than 10cm
more than 60cm
more than 25cm
More than 5cm
More than 10cm
Attention must be
paid to the rising
up of drain hose
6
Installation drawings of indoor and outdoor units
Connection cautions
model
connection priority between indoor and
stop valve higher from down to up
when there is 1 indoor,the prior stop
valve is
when there are 2 indoors,the prior
stop valves are
when there are 3 indoors,the prior
stop valves are
when there are 4 indoors,the prior
stop valves are
when there are 5 indoors,the prior
stop valves are
Note: For better oil return and more reliable system, please execute as the above when connecting indoor unit.
C
C B
C B A
D
D C
D C B
D C B A
E
E D
E D C
E D C B
E D C B A
7
20
Precautions on Installation
Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installed.
In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts.(Prepare four sets of M8 or M10
foundation bolts, nuts and washers each which are available on the market.)
It is best to screw in the foundation bolts until their length are 20mm from the foundation surface.
Outdoor Unit Installation Guideline
Where a wall or other obstacle is in the path of outdoor unit's intake or exhaust airflow, follow the installation guidelines below.
For any of the below installation pattems, the wall height on the exhaust side should be 1200mm or less.
Limitations on the installation
2.Selecting a location for installation of the indoor units
The maxinum allowable length of refrigerant piping, and the maxmum allowable height difference between the outdoor and indoor units,
are listed below. (The shorter the refrigerant piping, the better the performance. Connect so that the piping is as short as possible. Shortest
allowable length per room is 3m)
1.Precautions on installation
Check the strength and level of the installation ground so that unit will not cause any operating vibration or noise after installation.
In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts.
It is best to screw in the foundation bolts unit their length are 20 mm from the foundation surface.
More than 50 More than 300
1200 or
less
Side view
Wall facing one side
More
than 100
More
than 100
More
than 50
More
than 300
Side view
Wall facing two sides
More than 150
More
than 50
More than 300
Side view
Wall facing three sides
8
Refrigerant piping work
1. Installing outdoor unit
1) When installing the outdoor unit, refer to "Precautions for Selecting the Location" and the "Indoor/Outdoor Unit Installation Drawings".
2)If drain work is necessary, follow the procedures below.
2. Drain work
1) Use drain plug for drainage.
2) If the drain port is covered by a mounting base or floor surface, place additional foot bases of at least 30mm in height under the
outdoor unit's feet.
3) In cold areas, do not use a drain hose with the outdoor unit.(Otherwise, drain water may freeze, impairing heating performance.)
Drain elbow
Hose
Drain elbow
Hose
Indoor Unit
Outdoor Unit
Level
difference:
15m max.
Level
difference:
7.5m max.
If the outdoor unit is positioned higher than the indoor units.
Outdoor Unit
Indoor Unit
Level
difference:
15m max.
Level
difference:
7.5m max.
If the outdoor unit is positioned higher than the indoor units.
(If lower than one or more indoor units.)
Limitations on the installation
9
4. Purging air and checking gas leakage
WARNING
3. Refrigerant piping work
When piping work is completed, it is necessary to purge the air and check for gas leakage.
1) Do not mix any substance other than the specified refrigerant (R410A) into the refrigeration cycle.
2) When refrigerant gas leaks occur, ventilate the room as soon and as much as possible.
3) R410A, as well as other refrigerants, should always be recovered and never be released directly into the environment.
4) Use a vacuum pump for R410A exclusively. Using the same vacuum pump for different refrigerents may damage the vacuun pump
or the unit.
If using additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then charge additional
refrigerant.
Use a hexagonal wrench (4mm) to operate the stop valve rod.
All refrigerant pipe joints should be tightened with a torque wrench at the specified tightening torque.
Connect projection side of charging hose(Which comes from gauge manifold) to gas stop valve's service port.
Fully open gauge manifold's low-pressure valve(Lo) and completely close its high-pressure valve(Hi).
(High-pressure valve subsequently requires no operation.)
Apply vacuum pumping. Check that the compound pressure gauge reads-0.1MPa(-76cmHg).
Evacuation for at lease 1 hour is recommended.
Close gauge manifold's low-pressure valve(Lo) and stop vacuum pump.
(Leave as is for 4-5 minutes and make sure the coupling meter needie does not go back.
If it does go back, this may indicate the presence of moisture or leaking from connecting parts. After inspecting all the connection and
loosening then retightening thenuts, reqeat steps 2-4. )
Remove covers from liquid stop valve and gas stop valve.
Turn the liquid stop valve's rod 90 degrees counterclockwise with a hexagonal wrench to open valve.
Close it after 5 seconds, and check for gas leakage.
Using soapy water, check for gas leakage from indoor unit's flare and outdoor unit's flare and valve rods.
After the check is complete, wipe all soapy water off.
Disconnect charging hose from gas stop valve's service port, then fully open liquid and gas stop valves.
(Do not attempt to turn valve rodj beyond its stop.)
Tighten valve caps and service port caps for the liquid and gas stop valves with a torque wrench at the specified torques. See "3
Refrigerant piping " on page 6 for details.
Refrigerant piping work
2)To prevent gas leakage, apply refrigeration oil on both inner and outer surfaces of the flare. (Use refrigeration oil for R410A)
Torque spanner
Spanner
Pipe joint
Cone nut
10.8-14.7N.m(110-150kgf.cm)
Valve cap tightening torque
Liquid pipe 26.5-32.3N.m(270-330kgf.cm)
Gas pipe 48.1-59.7N.m(490-610kgf.cm)
Service port cap tightening torque
Coat here with refrigeration oil
1). Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the tor wrenches.
Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and escaping gas.
Flare nut fightening torque
14.2-17.2N.m(144-175kgf.cm)
32.7-39.9N.m(333-407kgf.cm)
49.5-60.3N.m(505-615kgf.cm)
61.8-75.4N.m(630-769kgf.cm)
Flare nut for 6.35
Flare nut for 9.52
Flare nut for 12.7
Flare nut for 15.88
10
5. Refilling the refrigerant
6. Charging with refrigerant
Notes:
Gas pipe
Gas pipe insulation
O.D.:9.52mm,12.7mm
Thickness:0.8mm
I.D.:12-15mm,12.7mm
Thickness:13mm min.
Liquid pipe
Liquid pipe insulation
O.D.:6.35mm
Thickness:0.8mm
I.D.:18-10mm
Thickness:10mm min.
7.Precautions for Laying Refrigerant Piping
Cautions on pipe handling
1) Protect the open end of the pipe against dust and moisture.
2) All pipe bends should be as gentle as possible. Use a pipe bender for bending.(Bending radius should be 30 to 40mm or larger.)
Selection of copper and heat insulation materials
When using commercial copper pipes and fittings, observe the following :
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK(0.035to 0.045kcal/mh
o
C)
Refrigerant gas pipe's surface temperature reaches 110
o
C max.
Choose heat insulation materials that will withstand this temperature.
2) Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below.
Check the type of refrigerant to be used on the machine namiplate.
Precautions when adding R410A
Fill from the liquid pipe in liquid form.
It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, preventing normal operation.
1) Before filling, check whether the cylinder has a siphon attached or not.(It should have something like "liquid filling siphon attached"
displayed on it.)
2) Be sure to use the R410A tools to ensure pressure and to prevent foreign objects entering.
1) This system must use refrigersant R410A.
2) Add refrigerant 20g per meter when the total piping length
exceeds the standard value, but make sure that the total liquid
piping length should be less than the max. value.
1) When using this product, you need not to set the address. But the L/N wires between indoor & outdoor units must be corresponded,
or there will be communication failure.
2) Quiet Operation Setting. Set the DIP "8" to ON position of SW5, the system will run with lower noise, but the max. capacity will also
reduce slightly.
3) Do not change the settings of other switchs, wrong settings can make the system damage or other malfunctions.
Refrigerant piping work
Filling a cylinder with an attached siphon
Stand the cylinder upright when filling.
There is a siphon pipe inside, so the
cylinder need not be upside-down
to fill with liquid.
Filling other cylinders
Turn the cylinder upside-down
when filing.
11
8.Cutting and Flaring work of piping
Pipe cutting is carried out with a pipe cutter and burs must be
removed.
After inserting the flare nut, flaring work is carried out.
Refrigerant Piping Work
WARNING
3) Use separate thermal insulation pipes for gas and liquid refrigerant
pipe.
It becomes high
midway.
The end is immersed
in water It waves.
Less than
5cm
It gap with the ground its
too small.
There is the bad
smell from a ditch.
Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out serely to outdoor.
In case that the attached drain hose is in a room, please apply heat insulation to it without fail.
9. On drainage
Please install the drain hose so as to be downward slope without fail. Please don't do the drainage as shown below.
Correct Incorrect
Lean Damage of flare Crack Partial Too outside
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would educe the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incom;ete flaring may cause refrigerant gas leakage.
Cut exactly at right
angles.
Remove burrs
Flare's inner
surface must be
flaw-free.
The pipe end
must be evenly
flared in a perfect
circle.
Make sure that the
flare nut is fitted.
Check
A
Flare tooling die
Pipe diameter Size A (mm)
Liquid side
Gas side
6.35mm(1/4")
9.52mm(3/8")
0.8~1.5
1.0~1.5
12.7mm(1/2") 1.0~1.5
Pipe
Be sure to
place a cap.
If no flare cap is
available, cover the
flare mouth with tape
to keep dirt or water
out.
Rain
Wall
Inter unit wiring
Gas pipe
Gas pipe
insulation
Finishing tape
Drain hose
Liquid pipe
insulation
Liquid pipe
A
Flare tooling die
Set exactly at the position shown below.
Flare tool for R410A
Clutch-type
0-0.5mm
Conventional flare tool
Clutch-type(Rigid-type)
1.0-1.5mm
Wing-nuttype(Imperial-type)
1.5-2.0mm
12
1. Electric wiring
The air conditioner must use special circuit , and wiring by the qualified electrician according to the wiring rules specified in national
standard.
The grounding wire and the neutral wire shall be strictly separated. Connect the neutral wire with grounding wire is incorrect.
The electric leakage breaker must be installed.
All the electric wire must be copper wire.Power supply:
The wiring method of power line is Y connection. If the power line is damaged, in order to avoid risk of electric shock, it must be replaced
by the manufacturer or its repair center or other similar qualified person.The connecting cable must be shielded.
Fuse: T3.15A 250VAC T16A 250VAC (Please check with the outdoor unit wiring diagram.)
Please check the circuit diagram about the fuse replaced.
Wiring method of orbicular terminals
For the connection wire with orbicular terminals, its wiring method is as shown in
the right figure: remove the connecting screw, put the screw through the ring on
the end of the wire, then connect to the terminal block and fasten screw.
Wiring method of straight terminals.
Crimp connection method for wires without terminals
For the connection wire without orbicular terminals, its wiring method is: loosen
the connection screw, and insert the end of the connection wire completely into
the Terminal block, then fasten the screw.
Slightly pull the wire outwards to confirm it is firmly held.
Note: Power line and communication wire are provided by consumers themselves.
Pump Down Operation
liquid
stop valve
Gas
stop valve
Valve cap
Hexagonal
wernch
Close
In order to protect the environment, be sure to pump down when relocating or disposing of the unit.
1) Remove the valve caps from liquid stop valve and gas stop valve.
2) Carry out forced cooling operation.
3) After five to ten minutes, close the liquid stop valve with a hexagonal wrench.
4) After two to three minutes, close the gas stop vaile and stop forced cooling
operation.
Crimp connection method for connection wire
After connection,the wire must be fastened by wire cover. The wire cover shall press on the protection
coat of the connection wire,as shown in right top figure.
Note:When connecting the wiring,confirm the terminal number of indoor and outdoor units carefully.
Incorrect wiring will damage the controller of air conditioner or the unit can not operate.
3. Wiring method of outdoor unit:
Power line
Remove the repair board of the outdoor unit and loosen the wire cover A,then put the live wire, neutral wire and grounding wire through
the wire cover ,and connect them to terminal block correspon dingly. After connection, fasten wire cover to its previous state.
Communication wire of indoor unit.
Loosen wire cover , put the communication wire through the wire cover B, and connect them to terminal block correspondingly. After
connection, fasten wire cover B to its previous state.
2. Wiring method
Wiring Method for
Ring Terminal Block
Connect the wire with
same diameter to the
two sides of the terminal
Do not connect the
wire with same diameter
to the same side
Do not connect the
wire with different
diameters
Wiring work
Correct Pressing
Wrong Pressing
Terminal
block
Pressing
Clamps
13
Wiring diagram please refers to
Loosen wire cover and connect the power line and communication wire of indoor unit to the terminal correspondingly.
Note:
When connecting power line to power supply terminal, please pay attention to the following items:
Do not connect the power line with different dimensions to the same connection wire end.
Improper contact will cause heat generation.
Do not connect the power line with different dimensions to the same grounding wire end.
Improper contact will affect protection.
Do not connect the power line to the connecting end of communication wire.
Incorrect connection will cause damage to the connected unit.
4. Wiring method of indoor unit
Wiring work
Valve cover
–¨ 25.400
Terminal block
Wire cover A
Wire cover B
Wire cover C
Wire cover A
Wire cover B
Wire cover C
Wire cover D
Wire cover E
Terminal block
Valve cover
5. Example wiring diagram.
14
Switch on all the 4 dip-switches on the outdoor unit small service PC-board as shown on the right. Then power
off the unit and power on again, the system will enter the operation of "Wiring Error Check". After 3 minutes
stand-by, the unit starts for automatic wiring checking.
Approximately 30 ~ 50minutes (depends on how many units installed in the system) after the unit starts, the
Errors of the wiring will be shown by the LEDs (1 to 5).
Before starting the test running, please confirm the following works have been done successfully.
1) Correct piping work;
2) Correct wiring work;
3) Correct match of indoor and outdoor unit;
4) Proper recharge of refrigerant if needed.
Make sure that all the stop valves are fully open.
Check the voltage supplied to the outdoor and indoor units, please cinfirm that is 230V.
Test running
Test running.
1) If the temperature is lower than 16
O
C, it is impossible to test cooling with remote controller, and also when the temperature is higher than
30
O
C, it is impossible to test heating.
2) To test cooling, set the lowest temperature at 16
O
C. To test heating,set the highest temperature, at 30
O
C.
3) Please check both cooling and heating operation of each unit individually and then also check the simultaneous operation of all indoor
units.
4) After ruuning the unit for about 20 minutes, check the indoor unit outlet temperature.
5) After the unit is stopped, or working mode changed, the system will not start again for about 3 minutes.
6) During cooling operation, frost may ocur on the indoor unit or pipes, this is normal.
7) Operate the unit according to the operation manual. Please kindly explain to our customers how to operate through the instruction manual.
ON
4321
CN2 CN3
CN1
CN4
SW1
4321
5
Seven-segment numeric display
1) When unit is runing, this seven-segment numeric will display the frequency of compressor. For
example," " means compressor running frequency is 40 Hz, " " means compressor running
frequency is 108Hz.
2) When faulty happens, seven-segment numeric will flash and display some numbers, this number is
failure code. For example, a flashing " " means No.32 failure, that is indoor and outdoor communication
error.
Communication LED
5 green LED means 5 indoor units. If one LED keep lighting that means the corresponding indoor unit has good communication with outdoor
unit. If one LED is not lighting, that means there is no communication between indoor and outdoor.
Wiring Error Check
This product is capable of automatic checking of wiring error.
ON
4321
CN2 CN3
CN1
CN4
SW1
4321
5
During this operation, the digital-number will alternately show the compressor working frequency (e.g. 50 stands for the current running
frequency) and letter "CH"(means checking).
After this operation, if all the wiring is correct, the digital-number will show "0", if there has wrong wiring, the digital-number will show "EC"(error
connection) and also it will flashing.
The service monitor LEDs indicate the error of wiring, as shown in the table below. For details about how to read the LED display, refer to
the service manual.
If self-checking is not possible, check the indoor unit wiring and piping in the usual manner.
Status
Only one LED flashing
15
Trouble shooting
Timer lamp
flash time
Running lamp
flash time
Faulty of outdoor unit EEPROM 1 15 2 1
IPM overcurrent or short circuit 2 16 2 2
Communication failure between Module and ECU
Communication cables broken or not well connected.
41824
Module operated overload 5 19 2 5
Module low or high DC voltage(under 192V or above
375V)
6 1A 2 6
Discharging temperature overheating.Lack of refrigerant,
ambient temperature too high or PMVs blocked.
81C28
Malfunction of the DC fan motor 9 1D 2 9
Malfunction of defrosting temp. sensor 10 1E 3 0
Malfunction of compressor suction temp. sensor 11 1F 3 1
Malfunction of ambient temp. sensor 12 20 3 2
Malfunction of compressor discharge temp. sensor 13 21 3 3
Communication failure between indoor&outdoor unit 15 23 3 5
Lack of refrigerant or discharging pipe blocked 16 36 3 6
4-way valve switching failure 17 25 3 7
Module overcurrent /Module switch failure 18 26 3 8
Indoor overload 20 28 4 0
Indoor frosted 21 29 4 1
Module temperature too high (Overload Protecter) 23 2B 4 3
Compressor overcurrent 24 2C 4 4
Input overcurrent 25 2D 4 5
MCU reset 26 2E 4 6
Module current detect circuit malfunction 27 2F 4 7
Malfunction of liquid pipe temp. sensor for indoor unit A 28 30 4 8
Malfunction of liquid pipe temp. sensor for indoor unit B 29 31 4 9
Malfunction of liquid pipe temp. sensor for indoor unit C 30 32 5 0
Malfunction of liquid pipe temp. sensor for indoor unit D 31 33 5 1
Malfunction of gas pipe temp. sensor for indoor unit A 32 34 5 2
Malfunction of gas pipe temp. sensor for indoor unit B 33 35 5 3
Malfunction of gas pipe temp. sensor for indoor unit C 34 36 5 4
Malfunction of gas pipe temp. sensor for indoor unit D 35 37 5 5
Malfunction of gas pipe temp. sensor for indoor unit E 36 38 5 6
Malfunction of module temp.sensor 38 3A 5 8
Malfunction of condensing temp. sensor 39 3B 5 9
Malfunction of liquid pipe temp. sensor for indoor unit E 40 3C 6 0
Malfunction of piping temp. sensor 41 3D 6 1
System high pressure switch off 42 3E 6 2
System low pressure switch off 43 3F 6 3
System high pressure protection.Refrigerant
overabundance,High condensing temp. or
malfunction of fan motor.
44 40 6 4
System low pressure protection.Refrigerant shortage,
Low defrosting temp., or malfunction of fan motor.
45 41 6 5
Malfunction of module temp.sensor 46 42 6 6
Cassette and convertible
indoor display outdoor error
code use the timer and runing
lamp
Wired
controller
display
Outdoor LED
display
Possible reasons
MANUAL DE INSTALACIÓN DEL APARATO DE AIRE
ACONDICIONADO DE TIPO MULTISPLIT
Contenido
Precauciones de seguridad
---------------- 3
Accesorios
------------------------------------ 4
Precauciones para seleccionar la
ubicación
---------------------------------------- 4
Esquemas de instalación de las
unidades
interior y exterior
------------------------------ 5
Precauciones a la hora de realizar
instalación
-------------------------------------- 7
Guía de instalación de la unidad
exterior
------------------------------------------ 7
Limitaciones en la instalación
------------- 7
Acometida de los tubos de
refrigerante
------------------------------------- 7
Funcionamiento de la bomba de
vacío
-------------------------------------------12
Cableado
--------------------------------------12
Prueba del aparato
--------------------------14
Resolución de problemas
-----------------15

Lea detenidamente este manual antes de instalar el aparato.
Guarde este manual de uso para futuras consultas.
Español
CONFORMIDAD DE LOS MODELOS
SEGÚN LAS NORMATIVAS EUROPEAS
CE
Todos los productos cumplen los requisitos de las siguientes
normas europeas:
- Directiva de baja tensión 73/23/CEE
- Directiva de baja tensión 2006/95/CE
- Compatibilidad electromagnética 89/336/CEE
- Compatibilidad electromagnética 2004/108/CE
ROHS
Los productos cumplen los requisitos de la directiva 2002/95/
CEE establecida por el Parlamento Europeo y el Consejo sobre
la Restricción del uso de determinadas sustancias peligrosas en
aparatos eléctricos y electrónicos (Directiva RoHS de la Unión
Europea).
WEEE
De acuerdo con la directiva 2002/96/CE del Parlamento Europeo,
se informa al consumidor acerca de los requisitos que han de
cumplirse para deshacerse de productos eléctricos y electrónicos.
REQUISITOS DE DESECHO:
Su aparato de aire acondicionado ha sido
marcado con este símbolo que significa que
los productos de tipo eléctrico y electrónico
no deben mezclarse con la basura doméstica
sin clasificar. No intente desmontar el sistema
por sí mismo: tanto el desmontaje del sistema de aire
acondicionado como la manipulación del refrigerante, el
aceite y cualquier otro componente deben ser llevados
a cabo por un instalador cualificado, de acuerdo con la
legislación local y nacional aplicable. Los aparatos de aire
acondicionado deben ser tratados en instalaciones de
manipulación especializadas para su reutilización, reciclado
y recuperación. Al garantizar la correcta eliminación de
este producto, estará contribuyendo a evitar las posibles
consecuencias negativas que podría provocar sobre el
medioambiente y la salud humana. Póngase en contacto
con el instalador o la autoridad local pertinente si desea
obtener más información. Las pilas deben ser extraídas del
mando a distancia y eliminadas de forma independiente, de
acuerdo con la legislación local y nacional aplicable.
INFORMACIÓN IMPORTANTE ACER-
CA DEL REFRIGERANTE UTILIZADO
Este producto contiene gases fluorados de efecto invernadero
regulados por el Protocolo de Kioto. No los libere a la atmósfera.
Tipo de refrigerante: R410A
Valor GWP*: 1975 1975
GWP = Potencial de contribución al calentamiento global
Escriba con tinta indeleble:
• 1 La carga de refrigerante que contiene el producto de fábrica
• 2 La cantidad de refrigerante adicional cargada in situ y
• 1+2 La carga total de refrigerante en la etiqueta de refrigerante
suministrada con el producto. Una vez escritos los datos
correspondientes, la etiqueta deberá adherirse cerca de la
conexión de carga del producto (por ejemplo, sobre la parte interna
de la cubierta de la válvula de retención).
A Contiene gases fluorados de efecto invernadero regulados por
el Protocolo de Kioto.
B Carga de refrigerante que contiene el producto de fábrica:
consulte la placa de características de la unidad.
C Cantidad de refrigerante adicional cargada in situ.
D Carga total de refrigerante.
E Unidad exterior.
F Botella de refrigerante y analizador para carga.
Haier Industrial Park, No.1 Haier Road, Qingdao, República Popular China
Contiene gases uorados de efecto invernadero
regulados por el Protocolo de Kioto.
Kg
Kg
Kg
Precauciones de seguridad
Lea estas precauciones de seguridad atentamente para garantizar la correcta instalación del aparato.
Este manual clasica las precauciones en los tipos
ADVERTENCIA y PRECAUCIÓN.
Asegúrese de tener en cuenta estas instrucciones. ya que son importantes para garantizar la seguridad.
ADVERTENCIA Si no se sigue alguna de las ADVERTENCIAS es probable que se produzcan consecuencias graves, como
lesiones personales o, incluso, la muerte.
PRECAUCIÓN El hecho de no seguir alguna de las PRECAUCIONES puede dar lugar a consecuencias graves.
En este manual se utilizan los siguientes símbolos de seguridad:
Asegúrese de tener en cuenta
estas instrucciones
.
Asegúrese de establecer una
conexión de toma de tierra.
No intentar nunca.
PRECAUCIÓN
No instale el aparato de aire acondicionado en un lugar en el que haya peligro de exposición a fugas de gas inamable.
Si el gas se fuga y se acumula alrededor de la unidad, se puede producir un incendio.
Establezca los tubos de desagüe conforme a las instrucciones este manual.
Una canalización inadecuada puede provocar inundaciones.
Apriete la tuerca abocardada conforme al método especicado utilizando una llave dinamométrica.
Si la tuerca abocardada se aprieta demasiado, podría agrietarse lo que daría lugar a fugas de refrigerante después de un largo período de uso.
Asegúrese de proporcionar las medidas adecuadas para evitar que la unidad exterior se utilice como refugio para animales pequeños.
Los animales pequeños pueden entrar en contacto con componentes eléctricos y causar averías, humo o un incendio. Indique al cliente que mantenga limpia el área
alrededor de la unidad.
3
Después de completar la instalación, pruebe la unidad para comprobar si hay errores en dicha instalación. Proporcione al usuario las
instrucciones adecuadas relativas al uso y la limpieza de la unidad conforme al manual de funcionamiento.
ADVERTENCIA
La instalación debe ser realizada por el distribuidor u otro profesional.
Una instalación incorrecta podría provocar fugas de agua, descargas eléctricas o un incendio.
Instale el aparato de aire acondicionado conforme a las instrucciones proporcionadas en este manual.
Una instalación incompleta podría provocar fugas de agua, descargas eléctricas o un incendio.
Asegúrese de utilizar los componentes de instalación suministrados o especicados.
El uso de otros componentes puede hacer que la unidad quede suelta, que haya fugas de agua, descargas eléctricas o que se produzca un incendio.
Instale el aparato de aire condicionado en una base sólida que soporte el peso de la unidad.
Una base inadecuada o una instalación incompleta puede provocar lesiones si la unidad se desprende de la base.
Las conexiones eléctricas deben ser llevadas a cabo conforme al manual de instalación y cumpliendo las normas de cableado eléctrico
nacionales y el código de práctica.
Una capacidad insuciente o unas conexiones eléctricas incompletas pueden provocar descargas eléctricas o un incendio.
Asegúrese de utilizar un circuito de alimentación dedicado. No utilice nunca una fuente de alimentación compartida por otro aparato.
Para el cableado, utilice un cable lo sucientemente largo como para cubrir toda la distancia sin empalmes.
No utilice un alargador. No coloque otras cargas en la fuente de alimentación y utilice un circuito de alimentación dedicado.
(Si no sigue estas indicaciones, el funcionamiento en modo de calefacción puede ser anómalo o se pueden producir descargas eléctricas o un incendio.)
Utilice los tipos especicados de cables para las conexiones eléctricas entre las unidades interior y exterior.
Sujete rmemente con abrazaderas los cables de interconexión de forma que sus terminales no sufran tirones producidos por fuerzas externas. Las conexiones o sujeción
con abrazaderas incompletas pueden provocar sobrecalentamiento en los terminales o un incendio.
Después de conectar todos los cables asegúrese de darles la forma adecuada para que no estén sometidos a una fuerza excesiva en
las tapas o paneles eléctricos.
Instale las tapas sobre los cables. Una instalación incompleta podría provocar sobrecalentamiento en los terminales, descargas eléctricas o un incendio.
Si ha habido fugas de refrigerante durante la instalación, ventile la habitación.
(El refrigerante produce un gas tóxico si se expone a las llamas.)
Una vez realizada la instalación, asegúrese de que no hay fugas de refrigerante.
(El refrigerante produce un gas tóxico si se expone a las llamas.)
Cuando se instale o cambie de ubicación el sistema, asegúrese de que no hay sustancias distintas al refrigerante especicado (R410A)
en el circuito refrigerante, como por ejemplo aire.
(Cualquier presencia de aire u otra sustancia extraña en el circuito refrigerante, provocará una elevación de la presión anormal o rupturas, lo que provocará lesiones personales.)
Durante el vaciado, detenga el compresor antes de quitar los tubos de refrigerante.
Si el compresor sigue en funcionamiento y la válvula de retención se abre durante el vaciado, el aire se succionará cuando el compresor esté en funcionamiento, lo que
provocará una presión anormal en el circuito refrigerador que dará lugar a fugas e, incluso, a lesiones personales.
Asegúrese de establecer una conexión de toma de tierra. No utilice tubos, cables, ni la toma de tierra del teléfono para conectar a tierra
la unidad.
Una conexión a tierra incompleta puede provocar descargas eléctricas o un incendio. Una fuerte subida de corriente causada por rayos u otras fuentes, puede
provocar daños en el aparato de aire acondicionado.
Asegúrese de instalar un interruptor de fugas a tierra.
Si no instala un interruptor de fugas a tierra se pueden producir descargas eléctricas o un incendio.
4
Accesorios
Accesorios suministrados con la unidad exterior:
Dibujo
Nombre de los
componentes
Cantidad Nota
1
Codo de desagüe
1
3
2
Protección de goma 4
3
Abrazadera
1
3
4
Adaptador (3/8
1/2) 1
5
Adaptador (1/2
3/8) 1
Precauciones para seleccionar la ubicación
1) Elija un lugar lo sucientemente resistente como para soportar el peso y las vibraciones de la unidad y donde el ruido de
funcionamiento no se amplique.
2) Elija una ubicación en la que el aire caliente emitido por la unidad o el ruido de funcionamiento no causen molestias a los
vecinos del usuario.
3) Evite los lugares cercanos a dormitorios y dependencias similares para que el ruido de funcionamiento no ocasione
problemas.
4) Debe haber un espacio suciente en el lugar de la instalación para meter y sacar la unidad.
5) Debe haber un espacio suciente en el lugar de la instalación para que uya el aire y no debe haber obstáculos
alrededor de la entrada y salida de aire.
6) En las proximidades del lugar de la instalación no debe existir la posibilidad de fugas de gas inamable.
Coloque la unidad de forma que el ruido y el aire caliente emitido no molesten a los vecinos.
7) Instale las unidades, los cables de alimentación y los cables que conectan las unidades a una distancia de al menos 3
metros de equipos de televisión y radio. De esta forma se evitarán interferencias en la imagen y el sonido. (En función de
las condiciones de las ondas de radio, los ruidos pueden oírse incluso si hay más de tres metros de distancia.)
8) En áreas costeras u otros lugares con atmósfera salada o gas sulfato, la corrosión puede acortar el período de vida útil
del aparato de aire acondicionado.
9) Dado que el sistema de desagüe sale de la unidad exterior, no coloque nada que no resista la humedad debajo de dicha
unidad.
NOTA:
No se puede instalar colgándose del techo ni apilándolo.
Cuando utilice el aparato de aire acondicionado a una
temperatura ambiente exterior baja, asegúrese de seguir las
instrucciones descritas a continuación.
1) Para evitar la exposición al viento, instale la unidad
exterior con su lado de succión orientado hacia la pared.
2) Nunca instale la unidad exterior en una ubicación en la
que el lado de succión pueda estar expuesto directamente al
viento.
3) Para evitar la exposición al viento, es recomendable
instalar un deector en el lado de descarga del aire de la
unidad exterior.
4) En áreas donde nieve mucho, seleccione un lugar de
instalación en el que la nieve no afecte a la unidad.
PRECAUCIÓN
Construya una cubierta grande.
Construya un pedestal.
Instale la unidad a una altura
suciente del suelo como para evitar
que quede cubierta por la nieve.
5
Esquemas de instalación de las unidades interior y exterior
1. Cuando realice trabajos de conexión de tubos no conecte la derivación de tubo integrada ni la unidad exterior sin conectar antes la
unidad interior para poder añadir más tarde otra unidad interior. Asegúrese de que no entra suciedad o humedad por ambos lados de la
derivación integrada del tubo.
2. Es imposible conectar la unidad interior solamente para una habitación.
Si hay peligro de que la unidad se caiga, fíjela con pernos para suelo, con un cable o con otros medios.
Si la ubicación no dispone de un buen sistema de drenaje, coloque la unidad en una base de montaje nivelada (o en un pedestal de
plástico).
Instale la unidad exterior en una posición nivelada. Si no sigue estas indicaciones, se pueden producir fugas o acumulación de agua.
Izquierda
Más de 5 cm
Organización de la dirección de los
tubos
Izquierda trasera
Derecha trasera
Derecha
Debajo
Más de 10 cm
s de 10 cm
Corte el tubo de aislamiento térmico por la
longitud adecuada y envuélvalo con cinta
asegurándose de que no quedan huecos en la
línea de corte del tubo de aislamiento.
Más de 60 cm
Debe prestarse
atención a la
pendiente del
manguito de
desagüe
Más de 10 cm
Más de 25 cm
Envuelva el tubo el aislamiento con la cinta de
Consulte para ver la gura de instalaciónConsulte para ver la gura de instalación
6
Esquemas de instalación de las unidades interior y exterior
Precauciones para la conexión
modelo
prioridad de conexión
entre la unidad interior y
la válvula de retención
más alta de abajo a
arriba
cuando hay una unidad
interior, la válvula de
retención previa es
C D E
cuando hay 2 unidades
interiores, las válvulas de
retención previas son
C B D C E D
cuando hay 3 unidades
interiores, las válvulas de
retención previas son
C B A D C B E D C
cuando hay 5 unidades
interiores, las válvulas de
retención previas son
E D C B A
Nota: para mejorar el retorno del aceite y la fiabilidad del sistema, siga las indicaciones anteriores
cuando conecte la unidad interior.
cuando hay 4 unidades
interiores, las válvulas de
retención previas son
D C B A E D C B
7
Precauciones a la hora de realizar instalación
Compruebe la resistencia y el nivel de la supercie de la instalación para que la unidad no cause vibraciones o ruido durante su
funcionamiento después de instalada.
En función de los planos de los cimientos, je la unidad de forma segura mediante los pernos para suelo. (Prepare cuatro juegos de
pernos para suelo M8 o M10, tuercas y arandelas. Todos estos componentes están disponibles en el mercado.)
Atornille los pernos para suelo hasta que se hayan introducido 20 mm.
Guía de instalación de la unidad exterior
Siga las instrucciones de instalación que se indican a continuación cuando haya una pared u otros obstáculos en la trayectoria del ujo
de aire de entrada o salida de la unidad exterior.
Para cualquiera de los modelos de instalación siguientes, la altura de la pared del lado de la salida de aire debe ser de 1200 mm como
máximo.
Limitaciones en la instalación
1.Precauciones a la hora de realizar la instalación
Compruebe la resistencia y el nivel de la supercie de la instalación para que la unidad no cause vibraciones o ruido durante su
funcionamiento después de instalada.
En función de los planos de los cimientos, je la unidad de forma segura mediante los pernos para suelo.
Atornille los pernos para suelo hasta que se hayan introducido 20 mm.
2.Seleccionar una ubicación para la instalación de las unidades interiores
A continuación se muestran la longitud máxima permitida de los tubos de refrigerante y la diferencia de altura máxima permitida entre la
unidad exterior y las unidades interiores. Cuanto más cortos sean los tubos de refrigerante, mayor será el rendimiento. Por tanto, realice
las conexiones de forma que los tubos sean tan cortos como sea posible. La longitud más corta permitida por habitación es de 3 m.
Clase de capacidad de la unidad exterior
Tubos a cada unidad interior
Longitud total de los tubos entre todas las unidades
Más de 50 mm
Pared en un lado
Más de 300 mm
1200 mm
como
máximo
Vista lateral
Pared en dos lados
Más de
100 mm
Más de
300 mm
Más de
100 mm
Vista lateral
Más de
50 mm
Pared en dos lados
Más de
50 mm
Más de 150 mm
Más de 300 mm
Vista lateral
máximo.
máximo.
máximo.
máximo.
máximo.
máximo.
máximo.
máximo.
8
Limitaciones en la instalación
Codo de desagüe
Acometida de los tubos de refrigerante
1.Instalar la unidad exterior
1) Cuando instale la unidad exterior, consulte las secciones "Precauciones para seleccionar la ubicación" y "Esquemas de
instalación de las unidades interior y exterior".
2) Si es necesario realizar un desagüe, siga los procedimientos que se indican a continuación.
2.Desagüe
1) Utilice un tapón de desagüe para el drenaje.
2) Si el puerto de desagüe está tapado por la base de montaje o por la supercie del suelo, coloque unos pies adicionales
que tengan una altura de al menos 30 mm debajo de los pies de la unidad exterior.
3) En zonas frías, no utilice una manguera de desagüe con la unidad exterior ya que, de lo contrario, el agua del desagüe
se puede congelar, lo que afectará negativamente al rendimiento en el modo de calefacción.
Manguera
Codo de desagüe
Manguera
Unidad interior
Diferencia
de nivel:
15m
máximo.
Unidad exterior
Diferencia
de nivel:
7,5 m
máximo.
Si la unidad exterior no se coloca en una posición más elevada
que las unidades interiores.
Diferencia
de nivel:
15m
máximo.
Diferencia
de nivel: 7,5
m máximo.
Unidad interior
Unidad exterior
Si la unidad exterior no se coloca en una posición más elevada
que las unidades interiores. (Si se ubica en una posición más baja
que una o varias unidades interiores.)
Unidad interior
Unidad exterior
Si la unidad interior se coloca en una posición más elevada que las
unidades exteriores.
Diferencia
de nivel:
15m
máximo.
Diferencia
de nivel: 7,5
m máximo.
9
Acometida de los tubos de refrigerante
3. Acometida de los tubos de refrigerante
1) Alinee los centros de ambas tuercas abocardadas y apriételas girándolas tres o cuatro vueltas con la mano. A continuación, apriételas
completamente con las llaves dinamométricas. Utilice llaves dinamométricas cuando apriete las tuercas abocardadas para evitar daños
en las mismas y fugas de gas.
Par de apriete de las tuercas abocardadas
Tuerca abocardada para
6,35
14,2-17,2 N.m (144-175 kgf.cm)
Tuerca abocardada para
9,52
32,7-39,9 N.m (333^07 kgf.cm)
Tuerca abocardada para
12,7
49,5-60,3 N.m (505-615 kgf.cm)
Tuerca abocardada para
15,88
61,8-75,4 N.m (630-769 kgf.cm)
Par de apriete de la tapa de la válvula
Par de apriete de la tapa del puerto de
servicio
Tubo de líquido 26,5-32,3 N.m (270-330 kgf.cm)
10,8-14,7 N.m (110-150 kgf.cm)
Tubo de líquido 48,1-59,7N.m (490-610 kgf.cm)
2) Para evitar fugas de gas, aplique aceite refrigerante tanto a la supercie interior como exterior de la tuerca abocardada. Utilice aceite
refrigerante para R410A.
4. Purgar el aire y comprobar si hay fugas de gas
Cuando haya nalizado de realizar la acometida de los tubos es necesario purgar el aire y comprobar si hay fugas de gas.
1) No mezcle ninguna sustancia que no sea el refrigerante especicado (R41 OA) en el circuito de refrigeración.
2) Si hay fugas de gas refrigerante, ventile la habitación tan pronto y tanto como sea posible.
3) El refrigerante R410A, así como otros refrigerantes, siempre se deben recuperar y nunca se deben liberar directamente al medio
ambiente.
4) Utilice una bomba de vao exclusivamente para el refrigerante R410A. El uso de la misma bomba de vao para diferentes
refrigerantes puede dañar dicha bomba o la unidad.
Si añade más refrigerante, realice una purga de aire en los tubos de refrigerante y la unidad interior utilizando una bomba de vacío y
cargue después el refrigerante adicional.
Utilice una llave Allen (4 mm) para manipular la varilla de la válvula de retención.
Todas las uniones del tubo refrigerante se deben apretar con una llave dinamométrica con el par de torsión especicado.
Conecte el lado de proyección de la manguera de carga (procedente del analizador) al puerto de servicio de la válvula de retención.
Abra completamente la válvula de baja presión (Baja) del analizador y cierre totalmente su válvula de alta presión (Alta). Ya no tendrá
que manipular la válvula de alta presión.
Aplique la bomba de vacío. Compruebe que en el analizador de presión compuesto pone 0,1 MPa (-76 cmHg). Es recomendable que
la bomba de vacío esté funcionando durante al menos una hora.
Cierre la válvula de baja presión (Baja) del analizador y pare la bomba de vacío.
Deje que transcurran entre 4 y 5 minutos y asegúrese de que la aguja del analizador no retrocede.
Si retrocede, signica que hay humedad o fugas en los componentes unidos. Después de inspeccionar todas las conexiones y si hay
alguna pieza suelta vuelva a apretar todas las tuercas y repita los pasos 2 a 4.
Quite las tapas de la válvula de retención de líquido y de la válvula de retención de gas.
Gire la varilla de la válvula de retención de líquido 90 grados en sentido contrario a las agujas del reloj con una llave Allen para abrirla.
Ciérrela después de 5 segundos y compruebe si hay fugas de gas.
Mediante agua jabonosa, compruebe si hay fugas de gas en los abocardados de las unidades interior y exterior y en las varillas de la
válvula. Una vez realizadas todas las comprobaciones, quite el agua jabonosa.
Desconecte la manguera de carga del puerto de servicio de la válvula de retención de gas y, a continuación, abra completamente las
válvulas de retención de líquido y gas. (No intente girar más la varilla de la válvula una vez se haya detenido.)
Apriete las tapas de las válvulas y las tapas del puerto de servicio correspondientes a dichas válvulas con una llave dinamométrica
con el par de apriete especicado. Consulte la sección "3 Acometida de los tubos de refrigerante" en la página 6 para obtener más
detalles.
Recubrir esta zona con aceite
refrigerante
Llave de par torsiométrica
Llave ja
Unión del tubo
Tuerca abocardada
ADVERTENCIA
10
Acometida de los tubos de refrigerante
5. Rellenar el refrigerante
Compruebe el tipo de refrigerante que se debe utilizar en la placa de características de la máquina.
Precauciones al añadir refrigerante R410A
Rellene desde el tubo de líquido en forma de líquido.
Se trata de un refrigerante mixto, por lo que si se añade en forma de gas, la composición de dicho refrigerante puede
cambiar, lo que impedirá el funcionamiento normal del aparato.
1) Antes de rellenar el refrigerante, compruebe si la botella tiene acoplado un sifón (debe mostrar algo así como "sifón de
relleno de líquido acoplado").
2) Asegúrese de utilizar las herramientas R410A para garantizar la presión y evitar que entren objetos extraños.
6. Cargar con refrigerante
1) El sistema debe utilizar refrigerante R410A.
2) Añada 20 g de refrigerante por metro cuando la longitud
total de los tubos de líquido supere el valor estándar,
pero asegúrese de que dicha longitud es inferior al valor
máximo.
Notas:
1) Cuando utilice este producto, no es necesario establecer la dirección. Sin embargo, los cables UN entre las unidades
interior y exterior se deben conectar correctamente o, de lo contrario, habrá un error de comunicación.
2) Establecimiento del funcionamiento en modo de silencio. Establezca el interruptor DIP "8" en la posición de encendido
(ON) de SW5. El sistema funcionará con menor ruido pero la capacidad máxima también se reducirá ligeramente.
3) No cambie la conguración de los otros conmutadores ya que una mala conguración puede dañar el sistema o causar
otras averías.
7. Precauciones para colocar los tubos de refrigerante
Precauciones a la hora de manipular los tubos
1) Proteja al extremo abierto del tubo del polvo y la humedad.
2) Todas las curvaturas de los tubos deben ser tan suaves como sea posible. Utilice una curvadora de tubos para curvar
los tubos. El radio de curvatura debe ser de al menos 30 mm.
Selección del cobre y de los materiales aislantes del calor
Cuando utilice tubos y accesorios de cobre comerciales tenga en cuenta lo siguiente:
1) Material aislante: espuma de polietileno.
Tasa de transferencia de calor: 0,041 a 0,052 W/mK (0,035 a 0,045 kcal/mh °C)
La temperatura de la supercie del tubo de gas refrigerante alcanza los 110 °C como máximo.
Elija materiales aislantes de calor que soporten esta temperatura.
2) Asegúrese de aislar los tubos de gas y de líquido, y de proporcionar las dimensiones de aislante que se indican a
continuación.
Unidad exterior
Longitud estándar
total de los tubos de
líquido
Longitud total máxima
de los tubos de líquido
Tubo de gas Aislante del tubo de gas
D.E: 9,52 mm,12, 7 mm
Grosor: 0,8 mm
D.I.: 12-15 mm, 12,7 mm
Grosor: 13mm mínimo
Tubo de líquido Aislante del tubo de líquido
D.E.: 6,35 mm
Grosor: 0,8 mm
D.I.:18-10 mm
Grosor: 10 mm mínimo
Rellenar una botella con un sifón acoplado
Coloque la botella en posición vertical
cuando la rellene.
Hay un tubo con sifón el interior, por
lo que no es necesario poner la botella
boca abajo para rellenarla con líquido.
Rellenar otras botellas
Ponga la botella bocabajo cuando la
rellene.
11
Acometida de los tubos de refrigerante
3) Utilice tubos con aislante térmico independientes para los tubos de gas y de líquido refrigerante.
8. Corte y abocardado de los tubos
El corte de los tubos se realiza con un cortatubos e incluye la eliminación de las rebabas.
El abocardado se realiza después de introducir la tuerca abocardada.
Tubo Diámetro del tubo Tamaño A (mm)
Lado de
líquido
6,35mm (1/4") 0.8-1.5
Lado de
gas
9,52mm (3/8") 1.0-1.5
12,7 mm (1/2") 1.0-1.5
9. Desagüe
Instale la manguera de desagüe formando una pendiente descendiente de forma homogénea. A continuación se muestran
ejemplos de malas prácticas de desagüe.
Deposite agua en la bandeja de desagüe de la unidad interior y conrme que el drenaje se realiza correctamente hacia
fuera.
En caso de que la manguera de desagüe se encuentre en una habitación, asegúrese de aplicar aislante de calor
uniformemente.
1) No utilice aceite mineral en la pieza abocardada.
2) Evite que el aceite mineral entre en el sistema porque reducirá el período de vida útil de las unidades.
3) Nunca utilice tubos que ya se hayan utilizado para instalaciones anteriores. Utilice solamente componentes
proporcionados con la unidad.
4) Para garantizar el período de vida útil de esta unidad R410A nunca instale un secador en ella.
5) El material de secado puede disolver y dañar el sistema.
6) Un abocardado incompleto puede provocar fugas de gas refrigerante.
Cableado de la
unidad interior
Tubo de gas
Tubo de líquido
Aislante del
tubo de gas
Aislante del
tubo de líquido
Embellecedor
Manguera de desagüe
Comprobar
La supercie
interior del
abocardado
no debe tener
imperfecciones.
El extremo del tubo
debe estar abocardado
uniformemente y formar
un círculo perfecto.
Asegúrese de que la
tuerca abocardada está
ajustada
Lluvia
Asegúrese de
colocar una
tapa.
Si no hay una tapa
para abocardado
disponible, cubra la
boca del abocardado
con cinta para que
no entre sociedad ni
agua.
Pared
Corte exactamente en
ángulos rectos.
Eliminar las rebabas
Colocar exactamente en la posición que se muestra a continuación.
Molde del abocardador
Abocardador para R410A Abocardador convencional
De tipo acoplamiento
De tipo acoplamiento
(tipo rígido)
De tipo palometa
(tipo imperial)
0-0,5mm 1,0-1,5mm 1,5-2,0 mm
Correcto Incorrecto
Inclinado Abocardado dañado Grieta Parcial
Demasiado
fuera
ADVERTENCIA
Molde del abocardador
Se alza a medio
camino.
El extremo está
sumergido en agua.
La separación respecto
al suelo es demasiado
pequeña.
Hay mal olor de una
zanja
Está
ondulado.
Menos de
5 cm
12
Funcionamiento de la bomba de vacío
Para proteger el medio ambiente, asegúrese de realizar el vacío cuando cambie de emplazamiento la unidad o se deshaga de
ella
1) Quite las tapas de la válvula de retención de líquido y de la válvula de
retención de gas.
2) Ponga en marcha el aparato en el modo de funcionamiento de refrigeración.
3) Después de diez minutos, cierre la válvula de retención de líquido con una
llave Allen.
4) Después de dos o tres minutos, cierre la válvula de retención de gas y
detenga el funcionamiento del modo de refrigeración.
Cableado
1. Cableado eléctrico
El aparato de aire acondicionado dede utilizar un circuito especial y el cableado debe ser realizado por un electricista profesional
conforme a las normas estándar nacionales de cableado.
Es obligatorio separar el cable de tierra y el cable neutro. No se puede conectar el cable neutro con el cable de tierra.
Se debe instalar un interruptor de fugas eléctrico.
Todos los cables eléctricos deben ser de cobre. Fuente de alimentación: 1 PH, 220-230 V- y 50 Hz.
El método de cableado de la línea de alimentación debe ser una conexión en Y. Si la línea de alimentación está dañada, para evitar
descargas eléctricas, debe ser reemplazada por el fabricante, por su centro de reparaciones o por otra persona similar capacitada.
Fusible: T 3,15 A/250 VAC T 16 A/250 VCA (Compruebe el esquema de cableado de la unidad exterior).
Compruebe el esquema del circuito cuando vaya a cambiar el fusible.
2. Métodos de cableado
Método de cableado de terminales circulares. En el caso de cables de conexión
con terminales circulares, el método de conexión debe ser el que se muestra en
la gura de la derecha: quite el tonillo de conexión, páselo por la arandela situada
en el extremo del cable y, a continuación, realice la conexión con el bloque de
terminales y apriete el tornillo. Método de conexión de terminales cuadrados.
Para cables de conexión sin terminales circulares, el método de cableado es el
siguiente: aoje el tornillo de conexión, inserte el extremo del cable de conexión
completamente en el bloque de terminales y, a continuación, apriete el tornillo.
Tire ligeramente del cable hacia afuera para conrmar que está rmemente
sujeto.
Método de conexión de engarce para cables sin terminales
Método de conexión de engarce para el cable de conexión. Después de la conexión, el cable debe quedar sujeto por su cubierta. La
cubierta del cable presionará el recubrimiento de protección del cable de conexión tal y como se muestra en la gura superior derecha.
Nota: al conectar el cable, conrme el número de terminales de las unidades interior y exterior detenidamente. Si el cableado se realiza
incorrectamente, el controlador del aire acondicionado resultará dañado o la unidad puede dejar de funcionar.
3. Método de cableado de la unidad exterior:
Línea de alimentación
Retire la tarjeta de reparación de la unidad externa y aoje la cubierta del cable A. A continuación, coloque la fase, el neutro y la tierra a
través de la cubierta del cable y conéctelos al bloque de terminales según corresponda. Después de la conexión, apriete la cubierta del
cable para devolverla a su estado anterior. Cable de comunicación de la unidad interior.
Aoje la tapa del cable, coloque el cable de comunicación a través de la tapa de cable B y conéctelos al bloque de terminales según
corresponda. Después de la conexión, apriete la cubierta del cable B para devolverla a su estado anterior.
Nota: la línea de alimentación y el cable de comunicación no se incluyen.
Sujeción correcta Sujeción incorrecta
Bloque de
terminales
Abrazaderas
de sujeción
Método de cableado del
bloque de terminales con
arandela
Conecte cables con el
mismo diámetro a ambos
lados del terminal.
No conecte cables con
el mismo diámetro al
mismo lado.
No conecte cables
con diferentes
diámetros.
Válvula de retención de líquido
Llave Allen
Cerrar
Válvula de
retención
de gas
Tapa de
válvula
13
–¨ 25.400
Cableado
Tapa de cable A Tapa de cable C
Tapa de cable B Bloque de terminales
Tapa de válvula
Tapa de cable A Tapa de cable C
Tapa de cable B
Tapa de cable D
Tapa de válvula
Bloque de terminales
Tapa de cable E
4. Método de cableado de la unidad interior
Aoje la tapa del cable y conecte la línea de alimentación y el cable de comunicación de la unidad interior al terminal que corresponda.
Nota:
Cuando conecte la línea de alimentación al terminal de la fuente de alimentación preste especial atención a lo siguiente:
No conecte la línea de alimentación de diferentes tamaños al mismo terminal del cable de conexión. Un contacto inadecuado provocará
sobrecalentamiento.
No conecte la línea de alimentación de diferentes tamaños al mismo terminal del cable de tierra. Un contacto inadecuado afectará a la
protección.
No conecte la línea de alimentación al extremo de conexión del cable de comunicación. Una conexión incorrecta provocará daños en la
unidad conectada.
5. Ejemplo del sistema de cableado.
Para ver un esquema de cableado consulte 5U34HS1ERA
Dé a los cables la forma
debida para que no se
levante la tapa del servicio ni
otras piezas de la estructura.
Fije el cableado de derivación rmemente
mediante los 4 tornillos incluidos, tal y como
se muestra en la gura. Fije las conexiones
rmemente asegurándose de que no ejerce
demasiada presión sobre los terminales.
Utilice los cables
especicados y
conéctelos de forma
segura.
14
Prueba del aparato
Antes de iniciar el funcionamiento de prueba asegúrese de que las siguientes tareas se han realizado correctamente.
1) Conexión correcta de todos los tubos;
2) Conexión correcta del cableado;
3) Correspondencia correcta de las unidades interior y exterior;
4) Recarga adecuada del refrigerante en caso de que sea necesario.
Asegúrese de que todas las válvulas de retención están completamente abiertas.
Compruebe el voltaje suministrado a las unidades exterior e interior y asegúrese de que su valor es de 230 V.
Compruebe los errores del cableado.
Este producto es capaz de comprobar automáticamente los errores de cableado.
Coloque en la posición de encendido los 4 conmutadores DIP de la pequeña tarjeta de circuito impreso de servicio de la unidad exterior
tal y como se muestra a la derecha. A continuación, apague la unidad y vuelva a encenderla. El sistema entrará
en el modo de funcionamiento "Comprobación de errores de cableado". Después de 3 minutos en el modo de
espera, la unidad iniciará la comprobación automática del cableado.
Aproximadamente 30 ~ 50 minutos después (en función del número de unidades instaladas en el sistema) la
unidad arrancará y los errores de cableado se mostrarán en los LED (1 a 5).
Durante esta operación, el número digital mostrará alternativamente la frecuencia de trabajo del compresor (por
ejemplo, 50 signica la frecuencia de funcionamiento actual y las letras CH signican comprobación).
Después de esta operación, si todo el cableado es correcto, el número digital mostrará "0". Si hay algún error de
cableado, el número digital mostrará "EC" (error de conexión) y, al mismo tiempo, parpadeará.
Los LED de supervisión de servicio indican el error del cableado tal y como se muestra en la tabla siguiente. Para obtener detalles sobre
cómo leer los LED, consulte el manual de servicio.
Si no es posible realizar la comprobación automática, compruebe el cableado y la conexión de los tubos de la unidad interior
manualmente.
LED 1 2 3 4 5 Mensaje
Estado
APAGADO Unidad no conectada
TODOS intermitentes
No es posible realizar la
comprobación automática; error de
conexión en todas las unidades.
TODOS ENCENDIDOS
Todas las unidades están
correctamente conectadas
ENCENDIDO INTERMITENTE INTERMITENTE ENCENDIDO INTERMITENTE
ENCENDIDO: unidad correctamente
conectada
INTERMITENTE: unidad
incorrectamente conectada. Es
necesario cambiar el cableado
manualmente entre 2, 3 y 5.
ENCENDIDO INTERMITENTE INTERMITENTE ENCENDIDO ENCENDIDO
ENCENDIDO: unidad correctamente
conectada
INTERMITENTE: unidad
incorrectamente conectada. Es
necesario cambiar el cableado
manualmente entre 2 y 3.
Solamente un LED intermitente Anomalía.
Prueba del aparato.
1) Si la temperatura es inferior a 16 ºC, es posible comprobar la refrigeración con el mando a distancia. Asimismo, cuando la temperatura
es superior a 30 ºC, es posible comprobar el modo de funcionamiento de calefacción.
2) Para comprobar el modo de refrigeración, establezca la temperatura más baja en 16 °C.Para comprobar el modo de calefacción,
establezca la temperatura más alta en 30 .
3) Compruebe tanto el modo de funcionamiento de refrigeración como el modo de funcionamiento de calefacción de cada unidad
individualmente y, a continuación, compruebe también el funcionamiento simultáneo de todas las unidades interiores.
4) Después de que la unidad haya estado funcionando durante 20 minutos compruebe la temperatura de salida de la unidad interior.
5) Cuando la unidad se detenga o el modo de trabajo cambie, el sistema no se volverá a iniciar hasta que transcurran aproximadamente
3 minutos.
6) En el modo de funcionamiento de refrigeración, se puede producir escarcha en la unidad interior o en los tubos, lo cual es normal.
7) Utilice la unidad conforme al manual de funcionamiento. Explique al cliente cómo utilizar el aparato utilizando el manual de
instrucciones.
Pantalla numérica de siete segmentos
1) Cuando la unidad está funcionando, esta pantalla numérica de siete segmentos muestra la frecuencia del
compresor. Por ejemplo,
"
" signica que la frecuencia de funcionamiento del compresor es 40 Hz. " " signica que la frecuencia de
funcionamiento del compresor es 108 Hz.
2) Si se produce un error, la pantalla numérica de siete segmentos parpadeará y mostrará números; estos
números corresponden a códigos de error. Por ejemplo, si aparece " " parpadeando, signica el error nº 32, que
es un error de comunicación entre las unidades interior y exterior.
LED de comunicación
5 LED de color verde signican 5 unidades interiores. Si un LED se mantiene iluminado signica que la unidad interior correspondiente
tiene buena comunicación con la unidad exterior. Si un LED no se ilumina, signica que no hay comunicación entre las unidades interior y
exterior.
15
Resolución de problemas
Lámpara de temporizador
Veces de destello
Lámpara de funcionamiento
Veces de destello
Falla de la unidad exterior EEPROM 1 15 2 1
Sobrecorriente o cortocircuito de IPM 2 16 2 2
Falla de comunicación entre módulo y ECU.
Cables de comunicación están rotos o no están bien conectados.
418 2 4
Sobrecarga de módulo operado 5 19 2 5
Módulo de voltaje DC bajo o alto (bajo 192V o superior a
375V)
61A 2 6
Sobrecalentamiento de la temperatura de descarga. Falta de refrigerante, la
temperatura del ambiente es demasiada alta o PMVs está bloqueado.
81C 2 8
Mal funcionamiento del motor DC del ventilador . 9 1D 2 9
Mal funcionamiento del sensor de la temperatura de descongelación. 10 1E 3 0
Mal funcionamiento del sensor de la temperatura de succión del compresor. 11 1F 3 1
Mal funcionamiento del sensor de la temperatura del ambiente. 12 20 3 2
Mal funcionamiento del sensor de la temperatura de descarga del compresor. 13 21 3 3
Falla de comunicación entre la unidad interior y exterior. 15 23 3 5
Falta de freón 16 36 3 6
Falla de conmutación de la válvula de 4 vías. 17 25 3 7
Sobrecorriente de módulo /Falla de conmutación de módulo 18 26 3 8
Sobrecarga interior 20 28 4 0
Helado de interior 21 29 4 1
Temperatura demasiada alta del módulo (Protector de sobrecarga) 23 2B 4 3
Sobrecarga del compresor 24 2C 4 4
Sobrecorriente de entrada 25 2D 4 5
Reestablecimiento de MCU 26 2E 4 6
Corriente de módulo detecta el mal funcionamiento del circuito 27 2F 4 7
Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad
interior A
28 30 4 8
Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad
interior B
29 31 4 9
Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad
interior C
30 32 5 0
Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad
interior D
31 33 5 1
Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad
interior A
32 34 5 2
Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad
interior B
33 35 5 3
Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad
interior C
34 36 5 4
Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad
interior D
35 37 5 5
Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad
interior E
36 38 5 6
Mal funcionamiento del sensor de la temperatura de módulo 38 3A 5 8
Mal funcionamiento del sensor de la temperatura de condensación 39 3B 5 9
Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad
interior E
40 3C 6 0
Mal funcionamiento del sensor de la temperatura del tubo 41 3D 6 1
Apagado el interruptor del sistema de presión alta 42 3E 6 2
Apagado el interruptor del sistema de presión baja 43 3F 6 3
Protección del sistema de presión alta. Exceso de refrigerante, temperatura alta de
condensación o mal funcionamiento del motor de ventilador.
44 40 6 4
Protección del sistema de presión baja. Escasez de refrigerante, temperatura baja
de descongelación o mal funcionamiento del motor de ventilador.
45 41 6 5
Mal funcionamiento del sensor de la temperatura del módulo 46 42 6 6
casete y visualización convertible interior y exterior cóVisualización de
controlador con
cable
Visualización
de LED
exterior
Razones posibles
Dirección: No.1 Haier Road, Hi-tech Zone.Qingdao 266101 República Popular China
Contactos: TEL: +86-532-8893-6943; FAX: +86-532-8893-6999
Sitio web: www.haier.com
MANUALE D’INSTALLAZIONE DEL
CONDIZIONATORE DI TIPO MULTI-SPLIT
Indice
Precauzioni di sicurezza -------------------- 3
Accessori -------------------------------------- 4
Precauzioni per la selezione del luogo
d’installazione --------------------------------- 4
Schema per l’installazione dell’unità
interna ed esterna ---------------------------- 5
Precauzioni per l’installazione ------------- 7
Linee guida per l’installazione
dell’unità esterna ------------------------------ 7
Limitazioni per l’installazione -------------- 7
Tubature del refrigerante ------------------- 7
Operazioni di scarico ----------------------12
Collegamento dei cavi elettrici -----------12
Test ----------------------------------------------14
Risoluzione dei problemi ------------------15

Leggere con attenzione questo manuale prima dell'installazione.
Conservare questo manuale per riferimenti futuri.
Italiano
CONFORMITÀ AI REGOLAMENTI
EUROPEI PER I MODELLI
CE
Tutti i prodotti sono conformi alle seguenti disposizioni europee:
- Direttiva bassa tensione 73/23/CEE
- Direttiva bassa tensione 2006/95/CEE
- Compatibilità elettromagnetica 89/336/CEE
- Compatibilità elettromagnetica 2004/108/CE
ROHS
I prodotti sono conformi ai requisiti della direttiva 2002/95/CEE
del Parlamento e del Consiglio Europeo sulla limitazione dell'uso
di alcune sostanze pericolose nei dispositivi elettrici ed elettronici
(Direttiva RoHS UE).
WEEE
In conformità alla direttiva 2002/96/CE del Parlamento Europeo,
informiamo il consumatore relativamente ai requisiti per lo smalti-
mento dei prodotti elettrici ed elettronici.
REQUISITI PER LO SMALTIMENTO:
Il condizionatore è marchiato con questo simbo-
lo. Ciò significa che i prodotti elettrici ed elettro-
nici non devono essere smaltiti insieme ai rifiuti
urbani indifferenziati. Non tentare di aprire il
sistema da soli: Lo smantellamento del sistema
di condizionamento, il trattamento del refrigerante, dell’olio e
di altre parti, deve essere eseguito da un tecnico qualificato
in conformità alle norme locali e nazionali. I condizionatori
devono essere trattati presso strutture di trattamento spe-
cializzate per il riutilizzo, il riciclaggio e recupero. Assicuran-
dosi che questo prodotto sia smaltito in mood appropriato
si aiuterà nella prevenzione di potenziali effetti negativi sull’
ambiente e sulla salute umana. Contattare l'installatore o
l'autorità locale per ulteriori informazioni. Le batterie usate
del telecomando devono essere smaltite separatamente in
conformità alle norme locali e nazionali.
IMPORTANTI INFORMAZIONI RELATI-
VE AL REFRIGERANTE UTILIZZATO
Questo prodotto contiene gas serra fluorinato, oggetto del Proto-
collo di Kyoto. Non lasciar sfogare nell'atmosfera.
Tipo di refrigerante: R410A
Valore GWP*: 1975
GWP=global warming potential
Inserire, con inchiostro indelebile,
• 1 il carico di refrigerante del prodotto inserito in fabbrica
• 2 il quantitativo aggiuntivo di refrigerante caricato sul campo e
• 1+2 Il totale di refrigerante caricato sull'etichetta di caricamen-
to del refrigerante fornita col prodotto. L'etichetta compilata deve
essere attaccata accanto alla porta di caricamento del prodotto (es.
all'interno del coperchio con il valore di arresto).
A questo prodotto contiene gas serra fluorinato, trattato nel Proto-
collo di Kyoto
B carico di refrigerante del prodotto inserito in fabbrica: vedere la
piastra con il nome dell'unità
C Il refrigerante aggiuntivo caricato durante l'installazione
D Il totale di refrigerante caricato
E Unità esterna
F F cilindro di refrigerante e collettore per la carica
Haier Industrial Park, N.1 Haier Road, Qingdao, Repubblica Popolare Cinese

trattato nel Protocollo di Kyoto
Kg
Kg
Kg
Precauzioni di sicurezza
Leggere accuratamente queste Precauzioni per la sicurezza per garantire la corretta installazione.

Accertarsi di osservare tutte le precauzioni che seguono: sono tutte importanti per garantire la sicurezza.
AVVISO La mancata osservanza di qualsiasi AVVISO può provocare gravi conseguenze come lezioni o morte.
ATTENZIONE La mancata osservanza di qualsiasi richiamo all’ATTENZIONE in alcuni casi può provocare gravi conseguenze.
In questo manuale sono usati i simboli che seguono:
Assicurarsi di osservare queste istruzioni
.
Assicurarsi si eseguire la messa a terra. Non tentare mai.
ATTENZIONE

Se il gas si accumula attorno all’unità c’è il pericolo di incendi.
Posare il tubo di scarico come da istruzioni di questo Manuale.
La posa inadeguata dei tubi può provocare allagamenti.

Se il dado svasato è stretto troppo, col tempo può spaccarsi e provocare la perdita di refrigerante.
Assicurarsi di prendere le misure adeguate per impedire che l’unità esterna diventi un rifugio per gli animali.
Piccoli animali possono entrare nell’unità ed entrare in contato con le parti elettriche provocando guasti, fumo o incendi. Istruire il cliente di tenere pulita e sgombra l’area
attorno all’unità.
3
                       -
guate riguardo all’uso ed alla pulizia dell’unità come indicato nel Manuale d’uso.
AVVISO
L’installazione deve essere eseguita dal rivenditore o da altro professionista.
L’installazione inappropriata può provocare perdite d’acqua, scariche elettriche o incendi.
Installare il condizionatore osservando le istruzioni date in questo Manuale.
L’installazione incompleta può provocare perdite d’acqua, scariche elettriche o incendi.

L’uso di altri pezzi può provocare l'allentamento dell’unità, perdite d’acqua, scariche elettriche o incendi.
Installare il condizionatore su una base solida che possa supportare il peso dell’unità.
Una base inadeguata o un’installazione incompleta può provocare lesioni in seguito alla caduta dell’unità dalla base.
I lavori elettrici devono essere eseguiti osservando il Manuale d’installazione e le norme nazionali o codice che regolano i lavori elettrici.

Accertarsi di usare un circuito elettrico dedicato. Non usare mai sorgenti d’alimentazione condivise con altre attrezzature.

Non usare prolunghe. Non caricare la sorgente d’alimentazione con altri carichi ed usare un circuito dedicato.
(Diversamente si può provocare surriscaldamento animalo, scariche elettriche e incendi.)


terminali o incendi.
Dopo avere collegato i cavi di collegamento e d’alimentazione, assicurarsi di disporre i cavi in modo che non esercitino pressioni sui
coperchi o pannelli delle scatole.
Installare i coperchi sopra i cavi. L’installazione incompleta dei coperchi può provocare il surriscaldamento dei terminali, scariche elettriche e incendi.
Se il gas refrigerante è fuoriuscito durante le operazioni di installazione, aerare il locale.

Al termine dell’installazione assicurarsi che non ci siano perdite di refrigerante.

Quando si installa o si spostare il sistema, assicurarsi di tenere libero il circuito del refrigerante da sostanze diverse dal refrigerante

(La presenza di aria o di altre sostanze estranee nel circuito del refrigerante provoca un anomalo aumento della pressione o rotture, causando lesioni.)
Per le operazioni di scarico, arrestare il compressore prima di rimuovere il refrigerante.
Se il compressore è ancora in funzione e la valvola d’arresto è aperta durante lo scarico, l’aria sarà aspirata provocando una pressione anomala nel ciclo di raffreddamento
che porterà a rotture e lesioni.
Assicurarsi di eseguire la messa a terra. Non collegare il cavo di messa a terra a tubature delle utenze, parafulmini o linee
telefoniche.
Una messa a terra inappropriata può provocare scariche elettriche o incendi. L’alta tensione dei fulmini o di altre origini può provocare danni al condizionatore.
Assicurarsi di installare un salvavita.
La mancata installazione del salvavita può provocare scariche elettriche o incendi.
4
Accessori
Accessori forniti in dotazione all’unità interna:
N. Diagramma Nomi delle parti Quantità Nota
1 Curvetta di scarico
1
3
2
Gommino 4
3
Bullone
1
3
4
Ancora (3/8
1/2) 1
5
Ancora (1/2
3/8) 1
Precauzioni per la selezione del luogo d’installazione
 -

2) Scegliere un luogo dove l’aria calda scaricata dall’unità ed il rumore di funzionamento non siano di disturbo ai vicini.
3) Evitare loghi vicini a stanze da letto e simili, così che il rumore di funzionamento non causi disagi.
 
 -
co dell’aria.
 
Installare l’unità in modo che il rumore e l’aria scaricata non disturbino i vicini.
7) Installare le unità, i cavi d’alimentazione ed i cavi di collegamento ad una distanza di almeno 3 metri da televisori e radio.
Questo per prevenire interferenze audio e video. (I disturbi possono essere notati anche a più di 3 metri di distanza, in base
alle condizioni delle onde radio.)
8) Nelle zone costiere ed altre aree con concentrazioni saline o di solfati nell’aria, la corrosione può accorciare la durata del
condizionatore.
9) Poiché lo scarico esce dall’unità esterna, non collocare sotto l’unità qualsiasi cosa che deve stare lontana dall’umidità.
NOTA:

Quando si usa il condizionatore e la temperature esterna è
bassa, assicurarsi si osservare le istruzioni che seguono.
1) Per impedire l’esposizione ai venti, installare l’unità ester-
na con la sua presa d’aria rivolta verso la parete.
2) Non installare mai l’unità esterna in luoghi dove la presa d’
aria può essere esposta ai venti.
3) Per prevenire l’esposizione ai venti, si raccomanda di

esterna.
4) Nelle aree soggette a forti nevicate, selezionare un luogo
dove la neve non interessa l’unità.
ATTENZIONE
Costruire un ampio riparo.
Costruire un piedistallo.

sollevata dal terreno per impedire
che sia sepolta dalla neve.
5
Schema per l’installazione dell’unità interna ed esterna
1. Assicurarsi che nel tubo di diramazione non penetrino sporcizia né umidità.
2. Al sistema devono essere collegate almeno due unità.

Se il luogo d’installazione non permette un buon scarico dell’acqua, collocare l’unità su una base piatta (o un piedistallo di plastica).
Installare l’unità esterna in posizione piatta. Diversamente si possono provocare perdite o accumulo dell’acqua.
Sinistra
p di 5 cm
Disposizione della direzione delle
tubature
Posteriore sinistra
Posteriore destra
Destra
Inferiore
p di 10 cm
più di 10 cm
Tagliare il tubo d’isolamento termico ad una
lunghezza appropriata ed avvolgerlo col nastro,
assicurandosi di non lasciare spazi sulla linea ti
taglio.
più di 60 cm
Deve essere pre-
stata attenzione al
sollevamento del

scarico
più di 10 cm
più di 25 cm
Avvolgere il tubo isolante col nastro partendo dal
basso e procedendo verso l’alto.
L’illustrazione fa riferimento al modello 4U30HS1ERA
6
Schema per l’installazione dell’unità interna ed esterna
Avvisi per il collegamento dei cavi
Modello
3U19FS1ERA
4U26HS1ERA
4U30HS1ERA
5U34HS1ERA
Priorità di collegamento
tra unità interna e valvola
d’arresto * più in alto
Quando c’è 1 unità
interna, la priorità di
valvola
C D E
Quando ci sono 2 unità
interne, la priorità di
valvola
C B D C E D
Quando ci sono 3 unità
interne, la priorità di
valvola
C B A D C B E D C
Quando ci sono 5 unità
interne, la priorità di
valvola
E D C B A

precedenza quando si collega l’unità interna.
Quando ci sono 4 unità
interne, la priorità di
valvola
D C B A E D C B
3U24GS1ERA
7
Precauzioni per l’installazione
• Controllare la forza ed il livello del luogo d’installazione in modo che l’unità non provochi vibrazioni o rumori dopo l’istallazione.
                 
M10, dadi e rondelle che sono disponibili sul mercato.)
                  
Linee guida per l’installazione dell’unità esterna
• Attenersi alle istruzioni che seguono quando una parete o altro ostacolo è di fronte alla resa o allo scarico dell’aria dell’unità.
• Per tutti i modelli d’installazione che seguono, l’altezza della parete sul lato dello scarico dell’aria deve essere di 1.200 mm o
meno.
Limitazioni per l’installazione
1. Precauzioni per l’installazione
• Controllare la forza ed il livello del luogo d’installazione in modo che l’unità non provochi vibrazioni o rumori dopo l’istallazione.


2. Selezione del luogo d’installazione per le unità interne
• Di seguito sono indicate la lunghezza massima consentita del tubo del refrigerante e l’altezza massima consentita tra l’unità
esterna e le unità interne. (Più corto è il tubo del refrigerante, migliori sono le prestazioni. Collegare in modo che il tubo sia il più
corto possibile. La lunghezza minima consentita per stanza è di 3 m)
Classe di capacità dell’unità esterna
Tubi a ciascuna unità interna
al massimo
Lunghezza totale dei tubi tra tutte le unità
Più di 50
Muro rivolto su un lato
Più di 300
1200 o
inferiore
Veduta laterale
Muro rivolto su due lati
Più di
100
Più di
300
Più di
100
Veduta laterale
Più di
50
Muro su tre lati
Più di 50
Più di 150
Più di 300
Veduta laterale
al massimo
al massimo
al massimo
al massimo
al massimo
al massimo
al massimo
8
Limitazioni per l’installazione
Curvetta di scarico
Tubature del refrigerante
1. Installazione dell’unità esterna
1) Quando si installa l’unità esterna, fare riferimento alle sezioni "Precauzioni per la selezione del luogo d’installazione" e
"Disegni per l’installazione dell’unità interna/esterna".
2) Attenersi alla procedura che segue se è necessario eseguire lo scarico dell’acqua.
2. Scarico dell’acqua
1) Usare l’attacco dello scarico per lo scarico.

almeno 30 mm l’unità esterna.
3) Nelle arre particolarmente fredde, non usare tubi di scarico con l’unità esterna. (Diversamente l’acqua può ghiacciare nel
tubo, compromettendo le prestazioni di riscaldamento.)
Tubo
Curvetta di scarico
Tubo
Unità interna
Dislivello:
15m al
massimo
Unità da esterno
Dislivello:
7.5m al
massimo
Se l’unità esterna è più alta delle unità interne.
Dislivello:
15m al
massimo
Dislivello:
7.5m al
massimo
Unità interna
Unità da esterno
Se l’unità esterna è più alta delle unità interne. (Se più bas-
sa di una o più unità.)
Unità interna
Unità da esterno
Se l’unità interna è più alta delle unità esterne.
Dislivello:
15m al
massimo
Dislivello:
7.5m al
massimo
9
Tubature del refrigerante
3. Tubature del refrigerante
1) Allineare il centro di entrambe le svasature e stringere a mano di 3 o 4 giri i dadi svasati. Poi stringerli completamente usando
una chiave dinamometrica. Usare la chiave dinamometrica quando si stringono i dadi svasati per prevenire danni ai dadi e per-
dite di gas.
Coppia di serraggio dei dadi svasati
Dado svasato per
6.35 14.2-17.2N.m (144-175kgf.cm)
Dado svasato per
9,52
32.7-39.9N.m (333^07kgf.cm)
Dado svasato per
12,7
49.5-60.3N.m (505-615kgf.cm)
Dado svasato per
15.88
61.8-75.4N.m (630-769kgf.cm)
Coppia di serraggio tappo valvola
Coppia di serraggio tappo porta di
servizio
Tubo del liquido 26.5-32.3N.m (270-330kgf.cm)
10.8-14.7N.m (110-150 kgf.cm)
Tubo del gas 48.1-59.7N.m (490-610kgf.cm)
                  
refrigerante R410A)
4. Sato dell’aria e controllo delle perdite di gas



3) Il refrigerante R410A, come anche antri refrigeranti, devono essere sempre recuperati e non devono mai essere smaltiti diretta-
mente nell’ambiente.
4) Usare una pompa per il vuoto apposita per R41 OA. L’uso della stessa pompa per il vuoto per vari tipi di refrigeranti può dan-
neggiare la pompa o l’unità.
                 
pompa a vuoto, poi caricare il refrigerante.
Usare una chiave esagonale (4 mm) per lavorare sulla valvola d’arresto.
                 
Collegare il tubo di caricamento (che esche dal manometro) alla porta di servizio della valvola d’arresto.
Aprire completamente la valvola di bassa pressione (Lo) del manometro e chiudere completamente la sua valvola dell’alta pres-
sione (Hi). (In seguito la valvola dell’alta pressione non richiede altre operazioni.)
Avviare la pompa per il vuoto. Controllare che il manometro indichi 0.1 MPa (-76cmHg). Si raccomanda l’evacuazione per alme-
no 1 ora.
Chiudere la valvola di bassa pressione (Lo) del manometro ed arrestare la pompa per il vuoto.
(Lasciare com’è per 4-5 minuti ed accertarsi che l’indicatore del manometro non torni indietro.

avere allentato e stretto di nuovo i dadi, ripetere le istruzioni di cui ai punti 2-4.)
Rimuovere il tappo dalla valvola d’arresto del liquido e del gas.
Girare di 90 gradi la leva della valvola d’arresto del liquido usando una chiave esagonale per aprire la valvola. Chiuderla dopo 5
secondi e controllare se ci sono perdite di gas.
Usando dell’acqua saponata, controllare se ci sono perdite di gas sulle svasature dell’unità interna, esterna e delle valvole. Al
termine del controllo, pulire tutta l’acqua saponata.
Scollegare il tubo di caricamento del gas dalla porta di servizio della valvola d’arresto, poi aprire completamente le valvole d’

Stringere i tappi delle valvole ed il tappo della porta di servizio delle valvole d’arresto del liquido e del gas usando una chiave


refrigerante
Chiave dinamometrica
Chiave per
bulloni
Raccordo
Dado conico
AVVISO
10
Tubature del refrigerante
5. Rabboccare il refrigerante

Precauzioni per quando si aggiunge il refrigerante R410A
Riempire dal tubo del liquido in forma liquida.
È un refrigerante miscelato, quindi aggiungerlo in forma gassosa può provocare il cambiamento della composizione del refri-
gerante, impedendo il normale funzionamento.
-
bocco in dotazione".)
2) Assicurarsi di usare attrezzi R41 OA per garantire la pressione ed impedire l’accesso di oggetti o sostanze estranee.
6. Caricamento del refrigerante
1) Questo sistema deve usare refrigerante R410A.
2) Aggiungere 20g di refrigerante per metro quando la
lunghezza totale dei tubi eccede il valore standard, però
accertarsi che la lunghezza totale dei tubi per liquidi non
ecceda il valore massimo.
Nota:
1) Non è necessario ipostare l’indirizzo quando si usa questo prodotto. Tuttavia i cavi UN che collegano le unità interne ed
esterna devono corrispondere, diversamente ci sarà un errore di comunicazione.
2) Impostazione modalità silenziosa. Impostare DIP "8" di SW5 sulla posizione ON, il sistema funzionerà in modalità silen-
ziosa, tuttavia la capacità massima sarà leggermente ridotta.

7. Precauzioni per la posa dei tubi del refrigerante
Precauzioni sulla manipolazione dei tubi
1) Proteggere l’estremità aperta del tubo da polvere e umidità.
2) Tutte le curve del tubo devono essere il più dolce possibile. Usare un piegatubi per piegare i tubi. (Il raggio della curva
deve essere di 30 - 40 mm o maggiore.)
Selezione del rame e dei materiali isolanti
Osservare quanto segue quando si usando tubi e raccordi di rame commerciali:
1) Materiali d’isolamento: Schiuma di polietilene
Velocità di trasferimento del calore: da 0.041 a 0.052W/mK (da 0.035 a 0.045kcal/mh°C)°C)°C)

Scegliere materiali isolanti che possono sopportare questa temperatura.
2) Assicurarsi di isolare i tubi del gas ed i tubi del liquido e di fornire l’isolamento come segue.
Unità da esterno
Lunghezza standard
tubi del liquido
Lunghezza massima
tubi del liquido
Tubo per gas Isolamento tubi del gas
Diametro esterno: 9,52 mm,
12,7 mm
Spessore: 0,8 mm
Diametro interno: 12-15 mm,
12,7 mm
Spessore: 13 mm minimo
Tubo per liquidi Isolamento tubi del liquido
Diametro esterno: 6,35 mm
Spessore: 0,8 mm
Diametro interno: 18-10 mm
Spessore: 10mm minimo
Riempimento di una bombola dotata di sifone
La bombola deve stare dritta durante il
riempimento.
All’interno c’è un sifone, quindi la
bombola non deve essere capovolta
per essere riempita.
Riempimento di altre bombole
Capovolgere a bombola durante il
riempimento.
11
Tubature del refrigerante
3) Usare tubature isolate termicamente separati per i tubi del gas e del refrigerante liquido.
8. Taglio e svasatura dei tubi
Il taglio dei tubi si esegue con un tagliatubi e le fresature devono essere rimosse.
Dopo avere inserito il dado svasato, si esegue il lavoro di svasatura.
Tubo Diametro del tubo
Dimensione A
(mm)
Lato del liqui-
do
6,35mm (1/4") 0.8-1.5
Lato del gas
9,52mm (3/8") 1.0-1.5
12.7mm (1/2") 1.0-1.5
9. Sullo scarico

mostrato di seguito.
Versare dell'acqua nel raccoglitore dell'unità interna ed accertarsi che sia scaricata in sicurezza all'esterno.
Se il tubo di scarico collegato si trova in una stanza, isolarlo in modo appropriato.
1) Non usare oli minerali sulle svasature.
2) Impedire all’olio minerale di penetrare nel sistema perché ridurrebbe la durata delle unità.
3) Non usare mai tubature che sono state usate in precedenti installazioni. Usare solo le parti fornite in dotazione all’unità.
4) Non installare mai materiali asciuganti su questa unità R41 OA per garantire a sua durata.
5) I materiali asciuganti possono dissolvere e danneggiare il sistema.
6) La svasatura incompleta può provocare perdite di gas refrigerante.
Collegamento dei cavi elettrici
dell’unità interna
Tubo per
gas
Tubo per
liquidi
Isolamento
tubi del gas
Isolamento tubi
del liquido


Controllo
-
terna della svasa-
tura deve essere
impeccabile.
L’estremità del tubo
deve essere svasata
uniformemente in un
cerchio perfetto.
Assicurarsi di installare i
dadi svasati
Pioggia
Assicurarsi
di mettere un
tappo.
Se non è disponibile
un tappo svasato,
coprire la svasatu-
ra con del nastro
per impedire che la
sporcizia o la pioggia
penetrino all’interno.
Parete
Tagliare esattamente
ad angolo retto.
Rimuovere le
sbavature
Posare esattamente nella posizione indicata di seguito.

Attrezzo per sva-
satura per R410A
Attrezzo convenzionale per svasatura
Tipo a frizione Tipo a frizione (tipo rigido) Tipo ad alette (tipo imperiale)
0 - 0,5 mm 1.0 - 1,5 mm 1,5 - 2,0 mm
AVVISO

A mezza via si
solleva.
L'estremità è immersa
nell'acqua
Lo spazio tra l'estremità ed il
terreno è troppo piccolo.
Ci sono cattivi odori che pro-
vengono da uno scolo.
È ondulato.
Inferiore a
5cm
Corretto Scorretto
Inclinato Danno della svasatura Rottura Parziale Troppo esterno
12
Operazioni di scarico
Per proteggere l’ambiente, assicurarsi di scaricare il refrigerante quando si trasloca o si smaltisce l’unità.
1) Rimuovere il tappo dalla valvola d’arresto del liquido e del gas.
2) Eseguire la procedura di raffreddamento forzato.
3) Dopo circa cinque, dieci minuti, chiudere la valvola d’arresto del liquido
usando una chiave esagonale.
4) Dopo circa due, tre minuti, chiudere la valvola d’arresto del gas ed arre-
stare la procedura di raffreddamento forzato.
Collegamento dei cavi elettrici
1. Collegamento dei cavi elettrici
Il condizionatore deve usare un circuito speciale, ed il collegamento dei cavi elettrici deve essere eseguito da un elettricista quali--

Il cavo di messa a terra e neutro devono essere separati distintamente. Il collegamento de cavo neutro insieme col cavo di mes--
sa a terra non è corretto.
Tutti i cavi devono essere di rame. Alimentazione: 1PH, 220-230V-, 50Hz.
Il metodo di collegamento della linea elettrica è di tipo Y. Se il cavo elettrico è danneggiato, per evitare il rischio di scosse elettri-YY -
-
mento devono essere schermati.

Fare riferimento al diagramma di collegamento dei cavi elettrici per la sostituzione del fusibile.
2. Metodo di collegamento
Metodo di collegamento dei terminali circolari Il metodo di collegamento dei


terminali e poi stringere la vite. Metodo di collegamento dei terminali dritti.
Il metodo di collegamento dei cavi ai terminali dritti è: Allentare la vite, inserire
completamente l’estremità del cavo di collegamento nel blocco terminali e poi
stringere la vite. Tirare delicatamente il cavo verso l’esterno per accertarsi che

Metodo di collegamento a crimpaggio per i cavi senza terminali
                    
copricavo. Il copricavo deve premere sulla guaina protettiva del cavo di collegamento, come mostrato nell’immagine di cui sopra.
Nota: Quando si collegano i cavi, controllare con attenzione i numeri di terminale dell’unità interna ed esterna. Il collegamento
scorretto dei cavi provocherà danni al telecomando del condizionatore e l’unità non funzionerà.
3. Il metodo di collegamento dei cavi dell’unità interna:
Linea elettrica
                   
di massa, neutro e di messa a terra, e poi collegare appropriatamente i cavi al blocco terminali. Dopo il collegamento, rimettere e

                     -

Nota: Il cavo elettrico ed il cavo di comunicazione sono forniti dall’utente stesso.
Collegare il cavo dello
stesso diametro ai due lati
del terminale
Non collegare il cavo
dello stesso diametro
sullo stesso lato
Non collegare cavi di
diametro diverso
Metodo di collegamento per
blocco terminali circolari
Pressione corretta
Pressione non corretta
Blocco
terminali
Pressione
dei morsetti
Valvola di interruzione
del liquido
Chiave
esagonale
Chiuso
Valvola di
interruzione
del gas
Tappo della
valvola
13
–¨ 25.400
Collegamento dei cavi elettrici
Coperchio scatola
dei cavi A
Coperchio scatola
dei cavi C
Coperchio scatola
dei cavi B
Blocco terminali
Coperchio valvola
Coperchio scatola
dei cavi A
Coperchio scato-
la dei cavi C
Coperchio scato-
la dei cavi B
Coperchio scatola
dei cavi D
Coperchio valvola
Blocco
terminali
Coperchio scato-
la dei cavi E
4. Metodo di collegamento dei cavi elettrici dell’unità interna
Allentare il coperchio della scatola dei cavi e collegare appropriatamente il cavo elettrico ed il cavo di comunicazione al blocco
terminali.
Nota:
Quando si collega il terminale d’alimentazione al terminale d’alimentazione, prestare attenzione a quanto segue:
Non collegare cavi d’alimentazione di dimensioni diverse alla stessa estremità di collegamento. Il contratto inappropriato provo--
cherà la generazione di calore.
Non collegare cavi d’alimentazione di dimensioni diverse alla stessa estremità di messa a terra. Il contratto inappropriato compro--
metterà la protezione.
Non collegare il cavo elettrico all’estremità di collegamento del cavo di comunicazione. Il collegamento scorretto provocherà dan--
ni all’unità collegata.
5. Esempio di diagramma di collegamento dei cavi
Per il diagramma di collegamento dei cavi fare riferimento a 5U34HS1 ERA
Collocare i cavi in modo
che non ci siano pressio-
ni sul coperchio o altre
parti della struttura.
Fissare i cavi in sicurezza usando le 4
viti incluse
Fissare in sicurezza, assicurandosi che
sui terminali non sia esercitata pressione
esterna.
-
cati e collegarlisicu-
rezza.
14
Test
Prima di avviare il test, accertarsi di avere portato a termine correttamente i seguenti lavori.
1) Tubature;
2) Collegamento dei cavi elettrici;
3) Corrispondenza corretta dell’unità interna ed esterna;
4) Rabbocco appropriato del refrigerante, se necessario.
Assicurarsi che tutte le valvole d’arresto siano completamente aperte.
 
Controllo errori di collegamento dei cavi
Questo prodotto è capace di controllare automaticamente se ci sono errori nei collegamenti dei cavi.
Accendere tutti i 4 interruttori DIP della PCB dell’unità esterna come mostrato sulla destra. Poi spegnere l’
unità e riaccenderla; il sistema accederà alla modalità di "Controllo errori di collegamento". Dopo 3 minuti di
standby, l’unità avvia il controllo automatico degli errori di collegamento dei cavi.
Circa 30 – 50 minuti dopo l’avvio dell’unità (il tempo dipende da quante unità sono installate sul sistema), i
LED (da 1 a 5) indicheranno gli errori di collegamento dei cavi.
Durante questa procedura, il display mostrerà alternatamene con numeri la frequenza operativa del com-
pressore (e.g. 50 sta per la freuenza operativa corrente) e la dicitura "CH" (che sta per “checking”, controllo).
Al termine di questa procedura, se il collegamento dei cavi è corretto, il display mostrerà "0", se invece ci sono errori, il display
mostrerà la dicitura "EC" (Errore Collegamento) che lampeggerà.
I LED del display indicano gli errori di collegamento, come mostrato nella tabella che segue. Fare riferimento al Manuale di servizio
per i dettagli su come leggere i LED.

LED 1 2 3 4 5 Messaggio
Stato
OFF (Spegnimento) Unità non collegata
Tutti lampeggianti
Controllo automatico impossibile, tutte le uni-
tà cono collegate in modo scorretto
Tutti accesi Tutte le unità sono collegate in modo corretto
ON Lampeggiante Lampeggiante ON Lampeggiante
Acceso: unità collegata correttamente Lam-
peggiante: Unità non collegata correttamen-

collegamento dei cavi tra 2, 3, e 5
ON Lampeggiante Lampeggiante ON ON
Acceso: unità collegata correttamente Lam-
peggiante: Unità non collegata correttamen-

collegamento dei cavi tra 2 e 3
Solo un LED lampeggiante Anomalia
Test in corso.
1) Quando la temperatura è inferiore ai 16° C, è impossibile eseguire il test di raffreddamento; quando la temperatura è superiore
ai 30° C, è impossibile eseguire il test di riscaldamento.
2) Per controllare il raffreddamento, impostare la temperatura minima a 16° C. Per controllare il riscaldamento, impostare la tempe-
ratura massima a 30° C.
3) Controllare individualmente la funzione sia di raffreddamento, sia di riscaldamento di ciascuna unità e controllare anche il fun-
zionamento simultaneo di tutte le unità interne.
4) Dopo che l’unità è in funzione da circa 20 minuti, controllare la temperatura emessa dall’unità interna.
5) Dopo avere arrestato l’unità, o dopo avere cambiato la modalità, l’unità non si riavvia per circa 3 minuti.
6) Durante il raffreddamento si può formare della brina sull’unità interna o sui tubi, questo è un fenomeno normale.
7) Usare l’unità osservando le istruzioni del Manuale d’uso. Spiegare accuratamente al cliente come funziona e come si usa il con-
dizionatore in base alle istruzioni del manuale d'uso.
Display numerico a sette cifre
1) Quando l’unità è in funzione, questo display numerico a sette cifre mostrerà la frequenza del compresso-
re. Ad esempio:
"
 
108Hz.
2) Quando c’è un guasto, il display numerico a sette cifre lampeggerà e visualizzerà dei numeri; questi
numeri sono il codice di errore. Ad esempio: "

comunicazione tra unità interna ed esterna.
LED comunicazione
-

15
Risoluzione dei problemi
Cronometro
lampada tempo
di flash
Lampada
all'esecuzione
tempo di flash
Guasto dell'unità esterna EEPROM 1 15 2 1
IPM sovracorrente o cortocircuito 2 16 2 2
Errore di comunicazione tra Modulo e ECU
I cavi di comunicazione rotto o non ben collegato.
4 18 2 4
Modulo operato sovraccarico 5 19 2 5
Modulo di tensione continua a bassa o alta (sotto 192V o superiore 375V) 6 1A 2 6
Scarico surriscaldamento temperatura. Mancanza di refrigerante, temperatura
ambiente troppo alta o PMV bloccato.
8 1C 2 8
Malfunzionamento del ventilatore motore a DC 9 1D 2 9
Malfunzionamento del sensore di temperatura di sbrinamento. 10 1E 3 0
Malfunzionamento del sensore di temperatura di aspirazione del compressore 11 1F 3 1
Malfunzionamento del sensore di temperatura ambiente 12 20 3 2
Malfunzionamento del sensore di temperatura di scarico del compressore 13 21 3 3
Errore di comunicazione tra unità interna ed esterna 15 23 3 5
Mancanza di freon 16 36 3 6
Valvola a 4 vie fallimento di commutazione 17 25 3 7
Modulo di sovracorrente / Modulo interruttore guasto 18 26 3 8
sovraccarico interno 20 28 4 0
Smerigliato interno 21 29 4 1
Modulo di temperatura troppo elevata (Protettore a sovraccarico) 23 2B 4 3
Compressore sovracorrente 24 2C 4 4
Ingresso sovracorrente 25 2D 4 5
MCU ripristino 26 2E 4 6
Modulo circuito di corrente rilevamento malfunzionamento 27 2F 4 7
Malfunzionamento del sensore di temperatura del liquido del tubo per l'unità A
interna
28 30 4 8
Malfunzionamento del sensore di temperatura del liquido del tubo per l'unità B
interna
29 31 4 9
Malfunzionamento del sensore di temperatura del liquido del tubo per l'unità C
interna
30 32 5 0
Malfunzionamento del sensore di temperatura del liquido del tubo per l'unità D
interna
31 33 5 1
Malfunzionamento del sensore di temperatura del gas del tubo per l'unità A
interna
32 34 5 2
Malfunzionamento del sensore di temperatura del gas del tubo per l'unità B
interna
33 35 5 3
Malfunzionamento del sensore di temperatura del gas del tubo per l'unità C
interna
34 36 5 4
Malfunzionamento del sensore di temperatura del gas del tubo per l'unità D
interna
35 37 5 5
Malfunzionamento del sensore di temperatura del gas del tubo per l'unità E
interna
36 38 5 6
Malfunzionamento del sensore di temperatura modulo 38 3A 5 8
Malfunzionamento del sensore di temperatura di condensazione 39 3B 5 9
Malfunzionamento del sensore di temperatura del liquido tubo per unità E
interna
40 3C 6 0
Malfunzionamento del sensore di temperatura tubazione 41 3D 6 1
Il sistema di pressione alta spento 42 3E 6 2
Il sistema di pressione bassa spento 43 3F 6 3
Protezione del sistema alla pressione alta.
Sovrabbondanza refrigerante, temperatura di condensazione elevata. O
malfunzionamento del motore del ventilatore.
44 40 6 4
Protezione del sistema alla pressione bassa.
Carenza di refrigerante, temperatura sbrinamento basso, O malfunzionamento
del motore del ventilatore.
45 41 6 5
Malfunzionamento del sensore di temperatura modulo 46 42 6 6
Cassette e convertibile interno
mostra il codice di errore esterno
utilizza il cronometro e lampada
all'esecuzione
Controllore
a cavo
mostra
LED esterno
mostra
Motivi possibili
Indirizzo: No. 1 Haier Road, Hi-tech Zone. Qingdao 266101 Repubblica Popolare Cinese
Contatti: TEL +86-532-8893-6943; FAX +86-532-8893-6999
Sito Internet: www.haier.com
MANUEL D'UTILISATION DU CLIMATI-
SEUR À PLUSIEURS BLOCS

Veuillez lire ce manuel attentivement avant d'installer l'appareil.
Conservez ce manuel d’utilisation pour toute référence ultérieure.
Table des matières
Consignes de sécurité ----------------------- 3
Accessoires ------------------------------------ 4
Précautions pour le choix de l'
Emplacement- --------------------------------- 4
Plans d’installation pour les unités
intérieures et extérieures ------------------- 5
Précautions relatives à l'installation ------ 7
Guide d'installation de l'unité extérieure 7
Limites relatives à l'installation ------------ 7
Travaux liés au tuyau du réfrigérant ----- 7
Fonctionnement de l'aspiration -----------12
Câblage ----------------------------------------12
Essai de fonctionnement ------------------14
Dépannage ------------------------------------15
Français
CONFORMITÉ DES MODÈLES
À LA LÉGISLATION EUROPÉENNE
CE
Tous les appareils sont conformes aux directives Européennes
suivantes :
- Directive basse tension 73/23/CEE
- Directive basse tension 2006/95/CE
- Compatibilité électro-magnétique 89/336/CEE
- Compatibilité électro-magnétique 2004/108/CE
ROHS
Les appareils répondent aux exigences de la directive 2002/95/
CEE du parlement européen et du conseil sur la limitation des
substances dangereuses dans les Équipements Électriques et
Électroniques (Directive UE RoHS).
DEEE
Conformément à la Directive 2002/96/CE du Parlement Européen,
nous informons ici-même le consommateur des conditions d'élimi-
nation des appareils électriques et électroniques.
CONDITIONS D'ÉLIMINATION
Votre climatiseur porte ce symbole. Ceci signifie
que les produits électriques et électroniques ne
doivent pas être mis au rebut avec les déchets
domestiques non triés. Ne pas tenter de démonter le sys-
tème par soi-même : le démontage du système de climatisa-
tion, le traitement du liquide réfrigérant, de l'huile et d'autres
pièces doivent être effectués par un installateur qualifié
conformément à la législation locale et nationale. Les clima-
tiseurs doivent être traités dans des installations spéciali-
sées pour réutilisation, recyclage et récupération. S'assurer
que le produit est éliminé de façon correcte permet d'aider
à éviter des conséquences potentielles négatives sur l'envi-
ronnement et la santé humaine. Merci de contacter l'instal-
lateur ou les autorités locales pour plus d'information. Les
piles doivent être enlevées de la télécommande et faire l'objet
d'une élimination séparée conformément à la législation
locale et nationale.
INFORMATIONS IMPORTANTES
CONCERNANT LE LIQUIDE RÉFRI-
GÉRANT UTILISÉ
Cet appareil contient des gaz à effet de serre fluorés couverts par
le protocole de Kyoto. Ne pas ventiler à l'air.
Type de réfrigérant : R410A
Valeur de GWP*: 1975
GWP = global warming potential - potentiel de réchauffement de la
planète.
Merci de remplir à l'encre indélébile;
• 1 La charge de réfrigérant usine de l'appareil
• 2 la quantité supplémentaire de réfrigérant chargée sur place
et
• 1+2 charge totale de réfrigérant sur l’étiquette de charge de
réfrigérant fournie avec le produit. L'étiquette renseignée doit être
collée à proximité du port de chargement de l'appareil (par ex.sur
l'intérieur du couvercle de valeur d'arrêt).
A contient des gaz à effet de serre fluorés couverts par le proto
-
cole de Kyoto.
B charge de réfrigérant usine de l'appareil : voir sur la plaque
signalétique de l'unité
C quantité supplémentaire de liquide réfrigérant chargée sur place
D Charge totale de réfrigérant
E Unité extérieure
F cylindre réfrigérant et orifice d'admission de chargement
Haier Industrial Park, No.1 Haier Road, Qingdao, RR. Chine
Contient des gaz à effet de serre uorés
couverts par le protocole de Kyoto.
Kg
Kg
Kg
Consignes de sécurité
Veuillez lire attentivement ces consignes de sécurité pour garantir la bonne installation de l'appareil.
Ce manuel classe les consignes sous AVERTISSEMENT et MISE EN GARDE.
Assurez-vous de suivre toutes les précautions ci-dessous : elles sont toutes importante pour garantir la sécurité.
AVERTISSEMENT Ne pas suivre l'un des AVERTISSEMENTS peut entraîner de graves conséquences, comme la mort ou une blessure grave.
MISE EN GARDE Ne pas suivre une des MISES EN GARDE peut entraîner dans certain cas de graves conséquences.
Les symboles de sécurité suivants, sont utilisés dans ce manuel :
Assurez-vous de vous conformer à cette instruction
.
Assurez-vous d'avoir établi une connexion à la terre. Ne jamais.
MISE EN GARDE
N'installez pas le climatiseur dans un endroit où il peut être exposé à une fuite de gaz inammable.
En cas de fuite de gaz et d'accumulation autour de l'unité, risque d'incendie.
Procédez à l'installation des tubulures de vidange conformément aux instructions de ce manuel.
Une mise en place inadéquate des tubulures peut entraîner une inondation.
Serrez l'écrou d'évasement selon la méthode spéciée, avec entre autre une clé dynamométrique.
Si l'écrou d'évasement est trop serré, il est susceptible de se ssurer après un certain temps et entraîner la fuite du liquide réfrigérant.
Assurez-vous de prendre les mesures adéquate pour éviter que l'unité extérieur ne puisse être utilisée comme abris pour les petits animaux.
Les petits animaux peuvent entrer en contact avec les pièces électriques entraînant des dysfonctionnements de l'appareil, une émission de fumée ou un
incendie. La zone autour de l'unité doit rester propre ; veuillez en informer le client.
3
Une fois l'installation effectuée, testez l'unité pour éliminer toute erreur liée à l'installation. Transmettez à l'utilisateur toutes les instructions adéquates,
concernant l'utilisation et le nettoyage de l'unité conformément au manuel d'utilisation.
AVERTISSEMENT
L'installation doit être effectuée par le fournisseur ou tout autre professionnel.
Une mauvaise installation peut entraîner des fuites d'eau, une électrocution, ou un incendie.
Installez le climatiseur conformément aux instructions indiquées dans ce manuel.
Une installation incomplète peut entraîner des fuites d'eau, une électrocution, ou un incendie.
Assurez-vous d'utiliser les pièces d'installation fournies ou spéciées.
L'utilisation d'autres pièces peut entraîner l'instabilité de l'appareil, des fuites d'eau, une électrocution, ou un incendie.
Installez le climatiseur sur une base solide capable de supporter le poids de l'unité.
Une base inadéquate ou une installation incomplète peut entraîner des blessures en cas de chute de l'unité de sa base.
Les travaux électriques doivent être effectués conformément au manuel d'installation et aux réglementations nationales relatives aux câblages, ou au
code de déontologie.
Une capacité insufsante ou des travaux électriques incomplets peuvent entraîner une électrocution ou un incendie.
Assurez-vous d'utiliser un circuit d'alimentation dédié. N'utilisez jamais une source d'alimentation partagée avec un autre appareil.
Pour le câblage, utilisez un câble sufsamment long pour parcourir la distance totale sans connexion intermédiaire.
N'utilisez pas de rallonge. Ne placez pas d'autres charges sur l'alimentation électrique. Utilisez un circuit d'alimentation dédié.
(Ne pas respecter cette consigne peut entraîner une chaleur anormale, une électrocution ou un incendie.)
Utilisez les types de câbles spéciés pour les connexions électriques entre les unités intérieure et extérieure.
Protégez les ls d'interconnexion avec des manchons pour que leurs borniers ne subissent aucune contrainte externe. Des connexions ou des mises
sous manchon incomplètes peuvent entraîner la surchauffe des borniers ou un incendie.
Après avoir effectué la connexion, les interconnexions et le câblage d'alimentation, assurez-vous de placer les câbles de façon à ce qu'ils ne reposent
pas en force sur les couvercles ou les panneaux électriques.
Installez les couvercles sur les câbles. Une installation incomplète des couvercles peut entraîner une surchauffe des borniers, une électrocution, ou un
incendie.
En cas de fuite du liquide réfrigérant pendant l'installation, ventilez la pièce.
(Le liquide réfrigérant produit un gaz toxique s'il est exposé à des ammes.)
Une fois l'installation effectuée, contrôlez l'absence de fuite de liquide réfrigérant.
(Le liquide réfrigérant produit un gaz toxique s'il est exposé à des ammes.)
Lorsque vous installez ou déplacez le système, assurez-vous de garder le circuit réfrigérant exempt de toute autre substance que le réfrigérant spécié
(R410A), comme de l'air.
(Toute présence d'air ou d'autre substance étrangère dans le circuit réfrigérant peut provoquer une augmentation anormale de la pression ou une rup-
ture, entraînant des blessures.)
Pendant l'aspiration, stoppez le compresseur avant de déposer le tuyau du réfrigérant.
Si le compresseur fonctionne encore et que la soupape d'arrêt est ouverte pendant l'aspiration, l'air sera aspiré dans l'appareil provoquant une pression
anormale dans le cycle du congélateur et entraînant sa rupture et même des blessures.
Assurez-vous d'avoir établi une connexion à la terre. Ne branchez pas l'appareil à la terre en utilisant une canalisation, un l de mise à la terre de para
-
foudre, ou la terre d'une ligne téléphonique.
Une mise à la terre incomplète peut entraîner une électrocution ou un incendie. Une surtension importante provoquée par la foudre ou une
autre source, peut entraîner des dommages au climatiseur.
Assurez-vous d'installer un disjoncteur de fuite à la masse.
Ne pas installer de disjoncteur de fuite à la masse peut entraîner une électrocution ou un incendie.
4
Accessoires
Accessoires fournis avec l'unité extérieure :
Plan Nom des pièces Quantité Remarque
1 Coude de vidange
1
3
2
Caoutchouc amortisseur 4
3
Coiffe
1
3
4
Adaptateur(3/8
1/2) 1
5
Adaptateur(1/2
3/8) 1
Précautions pour le choix de l'Emplacement
1) Choisissez un emplacement sufsamment solide pour supporter le poids et les vibrations de l'unité, un endroit où le bruit de fonction-
nement de l'unité ne sera pas amplié.
2) Choisissez un endroit où l'air chaud libéré par l'unité ni le bruit de fonctionnement ne causeront de nuisance à l'entourage de l'utilisateur.
3) Évitez les endroits à proximité d'une chambre à coucher par exemple. Le bruit de fonctionnement ne doit gêner personne.
4) L'espace doit être sufsant pour porter l'unité à l'intérieur du site et pouvoir la ressortir.
5) L'espace doit être sufsant pour le passage de l'air. Aucune obstruction ne doit se trouver autour de l'entrée et de la sortie d'air.
6) Le site et ses alentours doivent être exempts de tout risque de fuite de gaz inammable.
Placez l'unité de façon à ce que le bruit et l'air chaud libéré ne dérangent aucun voisin.
7) Installez les unités, les cordons d'alimentation et les câbles entre les unités à au moins 3 mètres de distance d'un poste de télévision
ou de radio. Ceci évitera toute interférence au niveau des images et du son. (Les bruits peuvent s'entendre même si l'unité est distante de
plus de 3 mètres, selon les conditions des ondes radio.)
8) Près des côtes et dans d'autres endroits présentant une atmosphère salée de gaz sulfaté, la corrosion peut réduire la durée de vie du
climatiseur.
9) L'eau de vidange coule hors de l'unité extérieure. Ne placez rien de sensible à l'humidité sous l'unité.
REMARQUE :
Ne pas suspendre au plafond, ne pas empiler les appareils.
Lorsque le climatiseur fonctionne alors que la température
ambiante extérieure est basse, assurez-vous de suivre les
instructions ci-dessous.
1) Pour éviter de l'exposer au vent, installez le côté aspira-
tion de l'unité extérieure vers le mur.
2) N'installez jamais l'unité extérieure avec son côté aspira-
tion exposé directement au vent.
3) Pour éviter tout exposition au vent, il est recommandé
d'installer une chicane du côté rejet d'air de l'unité extérieure.
4) En cas d'installation dans une région à fortes chutes de
neige, choisissez un endroit où la neige n'affecte pas l'unité.
MISE EN GARDE
Construction d'un grand écran
de protection.
Construction d'un support.
Installez l'unité à une hauteur sufsante
par rapport au sol, pour éviter que l'ap-
pareil ne soit recouvert de neige.
5
Plans d'installations pour les unités intérieures et extérieu-
res
1. Ne connectez pas le conduit de jonction intégré et l'unité extérieure au moment d'effectuer les travaux liés aux tuyaux, avant de connecter l'unité inté-
rieure, s'il s'agit d'ajouter ultérieurement une autre unité intérieure. Assurez-vous qu'aucune saleté ni humidité ne pénètre par l'une des deux extrémités du
conduit de jonction intégré.
2. Il est impossible de connecter l'unité intérieur pour une seule pièce.
En cas de risque de chute ou de basculement de l'unité, xez l'unité avec des boulons de fondation, un câble ou par tout autre moyen.
Si l'emplacement ne dispose pas de système de drainage adéquat, placez l'unité sur un socle de montage horizontal (ou un pied en plastique).
Installez l'unité extérieure à l'horizontale. Ne pas respecter l'installation horizontale peut entraîner des fuites d'eau ou une accumulation.
Gauche
plus de 5 cm
Disposition des directions de la tuyauterie
Arrière gauche
Arrière droite
Droite
En bas
plus de 10 cm
plus de 10 cm
Coupez le tuyau d'isolation thermique à la longueur
appropriée et enveloppez-le de ruban adhésif. As-
surez-vous qu'aucun espace n'est laissé au niveau
de la ligne de coupe du tuyau d'isolation.
plus de 60 cm
Il faut faire particu-
lièrement attention
au soulèvement du
tuyau de vidange.
plus de 10 cm
plus de 25 cm
Enveloppez le tuyau d'isolation de bas en
haut avec le ruban de nition.
Figure d'installation veuillez vous référer au 4U30HS1ERA
6
Plans d’installation pour les unités intérieures et extérieures
Avertissements relatives aux connexions
modèle
priorité au niveau de
la connexion de l’
unité intérieure et des
soupapes d’arrêt les plus
hautes, du bas vers le
haut
Lorsqu’il y a 1 unité
intérieure, la soupape d’
arrêt prioritaire est
C D E
Lorsqu’il y 2 unités
intérieures, les soupapes
d’arrêt prioritaires sont
C B D C E D
Lorsqu’il y 3 unités
intérieures, les soupapes
d’arrêt prioritaires sont
C B A D C B E D C
Lorsqu’il y a 5 unités
intérieures, les soupapes
d’arrêt prioritaires sont
E D C B A
Remarque : pour un meilleur retour d’huile et un système plus able, suivez les consignes ci-dessus
pour connecter l’unité intérieure.
Lorsqu’il y a 4 unités
intérieures, les soupapes
d’arrêt prioritaires sont
D C B A E D C B
7
Précautions relatives à l'installation
Vériez la résistance et l'horizontalité du lieu d'installation, de façon à ce que le fonctionnement de l'unité ne génère pas de vibration ou
de bruit une fois l'unité installée.
Fixez l'unité de façon sûre avec les boulons de fondation, conformément au plan des fondations. (Préparez quatre jeux de boulons de
fondation M8 ou M10, des écrous et des rondelles, le tout disponibles en magasin.)
Il est conseillé de visser les boulons de fondation en les enfonçant de 20 mm par rapport à la surface de la fondation.
Guide d'installation de l'unité extérieure
Si un mur ou tout autre obstacle se trouve sur le chemin du ux d'air d'entrée ou de sortie de l'unité extérieure, suivez les directives
d'installation ci-dessous.
Si vous utilisez l'un des plans d'installation suivant, la hauteur du mur côté sortie, doit être inférieure à 1 200 mm.
Limites relatives à l'installation
1. Précautions relatives à l'installation
Vériez la résistance et l'horizontalité du lieu d'installation, de façon à ce que le fonctionnement de l'unité ne génère pas de vibration ou
de bruit une fois l'unité installée.
Fixez l'unité de façon sûre avec les boulons de fondation, conformément au plan des fondations.
Il est conseillé de visser les boulons de fondation en les enfonçant de 20 mm par rapport à la surface de la fondation.
2. Choix d'un emplacement d'installation pour les unités extérieures
La longueur maximale autorisée du tuyau réfrigérant et la différence de hauteur maximale autorisée entre les unités extérieure et in
-
térieure, sont indiquées ci-dessous. (Plus le tuyau réfrigérant est court, meilleures sont les performances. Effectuez les connexion de
façon à ce que le tuyau soit le plus court possible. La longueur la plus courte autorisée par pièce est de 3 m.)
Classe de capacité de l'unité extérieure
Longueur des tuyaux vers chaque unité inté-
rieure
Longueur totale du tuyau entre toutes les
unités
Plus de 50
Mur d'un côté
Plus de 300
1200 ou
moins
Vue latérale
Mur des deux côtés
Plus de
100
Plus de
300
Plus de 100
Vue latérale
Plus de
50
Mur des trois côtés
Plus de
50
Plus de 150
Plus de 300
Vue latérale
8
Limites relatives à l'installation
Coude de vidange
Travaux liés au tuyau du réfrigérant
1. Installation de l'unité extérieure
1) Pour installer l'unité extérieure, veuillez vous référer aux sections "Précautions pour le choix de l'emplacement" et "Sché
-
mas d'installation des unités intérieures et extérieures".
2) Si des travaux de drainage sont nécessaires, suivez la procédure ci-dessous.
2. Travaux de drainage
1) Utilisez le bouchon de vidange.
2) Si l'orice de vidange est recouvert par un socle de montage ou par la surface du sol, placez des pieds supplémentaires
d'une hauteur minimale de 30 mm sous les pieds de l'unité extérieure.
3) Dans les régions froides, n'utilisez pas de tuyau de vidange pour l'unité extérieure. (L'eau de vidange risque en effet de
geler et de gêner les performances de chauffage.)
Tuyau
Coude de vidange
Tuyau
Unité intérieure
Différence
de niveau :
15m max.
Unité exté-
rieure
Différence
de niveau :
7,5m max.
Si l'unité extérieure est positionnée à un niveau plus élevé
que les unités intérieures.
Différence
de niveau :
15m max.
Différence
de niveau :
7,5m max.
Unité intérieure
Unité extérieure
Si l'unité extérieure est positionnée à un niveau plus élevé
que les unités intérieures. (Si elle est positionnée à un ni-
veau plus bas qu'une ou plusieurs unités intérieures.)
Unité intérieure
Unité extérieure
Si l'unité intérieure est positionnée à un niveau plus élevé
que les unités extérieures.
Différence
de niveau :
15m max.
Différence
de niveau :
7,5m max.
9
Travaux liés au tuyau du réfrigérant
3. Travaux liés au tuyau du réfrigérant
1) Alignez les centres des deux évasements et serrez à la mains les écrous d'évasement de 3 ou 4 tours. Puis serrez-les complètement avec une clé
dynamométrique. Utilisez les clés dynamométriques pour serrer les écrous d'évasement et éviter ainsi tout dommage au niveau des écrous ainsi que les
fuites de gaz.
Couple de serrage des écrous d'évasement
Écrou d'évasement pour
6,35
14,2-17,2 N.m (144-175 kgf.cm)
Écrou d'évasement pour
9,52
32,7-39,9 N.m (333^07kgf.cm)
Écrou d'évasement pour
12,7
49,5-60,3N.m (505-615 kgf.cm)
Écrou d'évasement pour
15,88
61,8-75,4N.m (630-769 kgf.cm)
Couple de serrage du capuchon de valve
Couple de serrage du capuchon de l'orice
d'entretien
Tuyau de liquide 26,5-32,3 N.m (270-330 kgf.cm)
10,8-14,7N.m (110-150 kgf.cm)
Tuyau de gaz 48,1-59,7N.m (490-610 kgf.cm)
2) Pour éviter toute fuite de gaz, appliquez de l'huile incongelable sur les surfaces intérieure et extérieure de l'évasement. (Utilisez l'huile incongelable pour
R410A)
4. Purger l'air et contrôler l'absence de fuite de gaz
Lorsque les travaux de tuyauterie sont terminés, il est indispensable de purger l'air et de contrôler l'absence de fuite de gaz.
1) Ne mélangez aucune autre substance que le réfrigérant spécié (R41 OA) dans le cycle de réfrigération.
2) En cas de fuite de gaz réfrigérant, ventilez la pièce aussi rapidement et autant que possible.
3) Le R410A, tout comme d'autres réfrigérants, doit toujours être récupéré. Il ne doit pas être jeté directement dans la nature.
4) Utilisez la pompe à vide destinée exclusivement pour le R41 OA. L'utilisation de la même pompe à vide pour différents réfrigérants peut endommager
la pompe ou l'unité.
Avant d'ajouter du réfrigérant, purgez l'air des tuyaux de réfrigération et de l'unité intérieure avec une pompe à vide, puis chargez le réfrigérant supplé
-
mentaire.
Utilisez une clé hexagonale (4mm) pour manipuler la tige de manoeuvre de la soupape d'arrêt.
Tous les joints des tuyaux de réfrigérant doivent être serrés en utilisant une clé dynamométrique et en appliquant le couple de serrage spécié.
Branchez le côté projection du tuyau de charge (qui vient du collecteur de jauge) à l'orice d'entretien de la soupape d'arrêt du gaz.
Ouvrez complètement la valve basse pression du collecteur de jauge (Lo) et fermez complètement sa valve haute pression (Hi). (La valve haute pres-
sion n'a habituellement pas besoin d'être manipulée.)
Procédez au pompage à vide. Contrôlez le manomètre du composé, il doit indiquer -0,1 MPa (-76 cmHg). Une évacuation d'au moins 1 heure est re-
commandée.
Fermez la valve basse pression du collecteur de jauge (Lo) et stoppez la pompe à vide.
(Patientez 4 à 5 minutes et assurez-vous que le l'aiguille du dispositif de mesure de couplage ne retourne pas en arrière.
Si elle retourne en arrière, cela indique la présence d'humidité ou une fuite au niveau des pièces de jonction. Après avoir inspecté toutes les connexions,
avoir desserré puis resserré les écrous, reprenez les étapes 2 à 4.)
Retirez les couvercles de la soupape d'arrêt liquide et de la soupape d'arrêt gaz.
Ouvrez la soupape en tournant la tige de manoeuvre de la soupape d'arrêt liquide de 90 degrés vers la gauche avec une clé hexagonale. Refermez la
soupape après 5 secondes, et contrôlez l'absence de fuites de gaz.
Utilisez de l'eau savonneuse et contrôlez l'absence de fuite de gaz au niveau de l'évasement de l'unité intérieure, de l'évasement de l'unité extérieure,
et des tiges de manoeuvre des soupapes. Une fois les vérications terminées, essuyez l'eau savonneuse.
Déconnectez le tuyau de charge de l'orice d'entretien de la soupape d'arrêt gaz, puis ouvrez complètement les soupapes d'arrêt gaz et liquide. (N'es-
sayez pas de tournez les tiges de manoeuvre des soupapes au-delà de leurs butées d'arrêt).
Serrez les capuchons des soupapes et de l'orice d'entretien des soupapes d'arrêt liquide et gaz avec une clé dynamométrique, en appliquant les cou-
ples spéciés. Voir la section "3 Tuyau du réfrigérant" à la page 6 pour plus de détails.
Appliquez ici de l'huile incon-
gelable
Clé dynamométrique
Clé
Joint de tuyau
Écrou en cône
AVERTISSEMENT
10
Travaux liés au tuyau du réfrigérant
5. Remplissage de liquide réfrigérant
Vériez le type de réfrigérant à utiliser sur la plaque signalétique du climatiseur.
Précautions lors de l'ajout du R410A
Effectuez le remplissage par du réfrigérant liquide depuis le tuyau de liquide.
S'il s'agit d'un réfrigérant mixte, l'ajout sous forme de gaz peut entraîner la modication de la composition du réfrigérant, gênant ainsi le
fonctionnement normal de l'appareil.
1) Avant le remplissage, vériez si le cylindre dispose d'un siphon relié ou non. (Le climatiseur doit alors porter une mention "siphon de
remplissage liquide relié").
2) Assurez-vous d'utiliser les outils R41 OA de façon à garantir la pression et d'éviter l'introduction d'objets étrangers.
6. Chargement du réfrigérant
1) Ce système doit utiliser le réfrigérant R410A.
2) Ajoutez 20g de réfrigérant par mètre lorsque la longueur totale
du tuyau dépasse la valeur standard. Assurez-vous cependant
que la longueur totale du tuyau de liquide est inférieure à la valeur
maximale.
Remarques :
1) Lorsque vous utilisez ce produit, il est inutile de dénir l'adresse. Les ls UN entre les unités intérieure et extérieure doivent correspon
-
dre. Si ce n'est pas le cas, la communication va échouer.
2) Paramétrage du fonctionnement silencieux. Réglez le DIP "8" sur la position ON du SW5. Le système va fonctionner en émettant
moins de bruit, mais la capacité maximale va également être légèrement réduite.
Ne modiez pas les paramétrage des autres interrupteurs. Un mauvais réglage peut endommager le système ou entraîner d'autres dys-
fonctionnements.
7. Précautions relatives à la mise en place du tuyau réfrigérant
Mise en garde relative à la manipulation du tuyau
1) Protégez l'extrémité ouverte du tuyau contre la poussière et l'humidité.
2) Tous les cintrages de tuyaux doivent être effectués avec précaution. Utilisez une cintreuse pour cintrer les tuyaux. (Le rayon de cin
-
trage doit être compris entre 30 et 40 mm, ou supérieur.)
Choix du cuivre et matériaux d'isolation thermique
Lorsque vous utilisez des tuyaux et des raccords en cuivre du commerce, respectez les consignes suivantes :
1) Matériau d'isolation : Mousse en polyéthylène
Coefcient de conductibilité calorique : de 0,041 à 0,052 W/mK (de 0,035 à 0,045 kcal/mh°C)
La température maximale de la surface du tuyau de gaz réfrigérant est de 110°C.
Choisissez des matériaux d'isolation thermique capables de supporter cette température.
2) Assurez-vous d'isoler le tuyau de liquide et le tuyau de gaz. Choisissez des dimensions d'isolation selon les indications suivantes.
Unité extérieure
Longueur standard to-
tale du tuyau de liquide
Longueur maximale to
tale du tuyau de liquide
Tuyau de gaz Isolation du tuyau de gaz
Diamètre extérieur : 9,52
mm,12,7 mm
Épaisseur : 0,8 mm
Diamètre intérieur : 12-15 mm,
12,7 mm
Épaisseur : 13mm min.
Tuyau de liquide Isolation du tuyau de liquide
Diamètre extérieur : 6,35 mm
Épaisseur : 0,8 mm
Diamètre intérieur : 18-10 mm
Épaisseur : 10 mm min.
Remplissage d'un cylindre avec le siphon relié
Maintenez le cylindre à la verticale pendant le
remplissage.
Le siphon contient un tuyau. Il ne faut
donc pas le mettre à l'envers pour le rem-
plir de liquide.
Remplissage des autres cylindres
Tournez le cylindre à l'envers pour le rem-
plir.
11
Travaux liés au tuyau du réfrigérant
3) Utilisez des tuyaux d'isolation thermique distincts pour le tuyau de réfrigérant liquide et le tuyau de réfrigérant gaz.
8. Travail de coupe et d'évasement de la tuyauterie
La coupe du tuyau doit être effectuée avec un coupe-tuyau. Vous devez nettoyer les bavures.
Après avoir inséré l'écrou évasé, vous pouvez procéder au travail d'évase
-
ment.
Tuyau
Diamètre du
tuyau
Taille A (mm)
Côté liquide 6,35mm (1/4”) 0.8-1.5
Côté gaz
9,52mm (3/8”) 1.0-1.5
12,7mm (1/2”) 1.0-1.5
9. Vidange
Installez le tuyau de vidange de manière à ce que la pente soit descendante. Ne pas effectuer la vidange comme illustré ci-dessous.
Versez de l'eau dans le bac de vidange de l'unité intérieure et vériez qu'il soit dirigé vers l'extérieur.
Si le tuyau de vidange est dans une pièce, utilisez une isolation thermique.
1) N'utilisez pas d'huile minérale sur les pièces évasées.
2) Empêchez que l'huile minérale ne pénètre dans le système, cela réduirait la durée de vie des unités.
3) N'utilisez pas de tuyaux ayant déjà été utilisés dans d'autres installation. N'utilisez que les pièces fournies avec l'unité.
4) Pour garantir sa durée de vie, n'installez jamais de déshydrateur sur cette unité R41 OA
5) Le matériau déshydrateur peut se dissoudre et endommager le système.
6) Un évasement insufsant peut entraîner la fuite du gaz réfrigérant.
Câblage dans l'unité
Tuyau de gaz
Tuyau de liquide
Isolation du
tuyau de gaz
Isolation du
tuyau de
liquide
Ruban de nition
Tuyau de vidange
Contrôle
La surface inté-
rieure de l'éva-
sement ne doit
présenter aucun
défaut.
L'extrémité du tuyau
doit être évasé de fa-
çon régulière et dessi-
ner un cercle parfait.
Assurez-vous que l'écrou
d'évasement est bien ins-
tallé.
Pluie
Assurez-vous
de placer un
capuchon.
Si aucun capuchon
n'est disponible,
couvrez l'ouverture de
l'évasement avec un
ruban pour empêcher
la saleté ou l'eau d'y
pénétrer.
Mur
Coupez exacte-
ment à angle droit.
Nettoyez les bavures
Positionnez exactement comme indiqué ci-dessous.
Matrice de l'outilla-
ge d'évasement
Outil d'évasement pour
R410A
Outil d'évasement classique
Type à embrayage
Type à embrayage
(rigide)
Type à écrou à oreilles
(Imperial)
0-0,5mm 1,0-1,5mm 1,5-2,0mm
Correct Incorrect
Insuf-
sant
Evasement endom-
magé
Fissure Partiel
Vers extérieur
AVERTISSEMENT
Matrice de l'outillage
d'évasement
Il est surélevé à
mi-chemin.
L'extrémité est immer-
gée dans l'eau
L'intervalle avec le sol est
trop petit.
Il y a une odeur nau-
séabonde de la fosse.
Il ondule.
Moins de
5 cm
12
Fonctionnement de l'aspiration
Pour protéger l'environnement, assurez-vous d'effectuer un pompage en cas de déplacement de l'unité ou lorsque vous
la mettez au rebut.
1) Retirez les couvercles de la soupape d'arrêt liquide et de la soupape
d'arrêt gaz.
2) Procédez à un refroidissement forcé.
3) Après cinq à dix minutes, fermez la soupape d'arrêt liquide avec une clé
dynamométrique.
4) Après deux à trois minutes, fermes la soupape d'arrêt gaz et stoppez le
refroidissement forcé.
Câblage
1. Câblage électrique
Le climatiseur doit utiliser un circuit spécial. Son câblage est à effectuer par un électricien qualié conformément aux réglementa
-
tions nationales en la matière.
Le câble de mise à la terre et le câble neutre doivent être strictement distincts. Brancher le câble neutre avec le câble de mise à
la terre est incorrect.
Installez un disjoncteur de fuite.
Tous les câbles électriques doivent être en cuivre. Alimentation : 1PH, 220-230V-, 50Hz.
La méthode de câblage de la ligne d'alimentation est une connexion en Y. Si la ligne d'alimentation est endommagée, et pour évi
-
ter tout risque d'électrocution, il faut la remplacer par le fabricant ou son centre de réparation ou toute autre personne qualiée.
Le câble de branchement doit être blindé.
Fusible : T3.15A250VAC T16A250VAC (veuillez consulter le schéma de câblage de l'unité extérieure.)
Veuillez consulter le schéma de circuit pour le remplacement du fusible.
2. Méthode de câblage
Méthode de câblage pour les bornes orbiculaires Pour la connexion des câ
-
bles avec des bornes orbiculaires, utilisez la méthode de câblage de la gure
de droite : retirez la vis de connexion, placez la vis dans la bague à l'extrémité
du câble, puis branchez le câble au bornier. Serrez la vis. Méthode de câble
pour les bornes droites.
Pour la connexion des câbles sans bornier orbiculaires, la méthode de câ
-
blage est la suivante : desserrez la vis de connexion et insérez l'extrémité du
câble de connexion complètement dans le bornier. Serrez ensuite la vis. Tirez
légèrement le l vers l'extérieur pour vérier s'il est bien maintenu.
Méthode de connexion sertie pour les câbles sans borne
Méthode de connexion sertie pour câble de connexion Après le branchement. le l doit être maintenu par un recouvrement. Le
recouvrement doit appuyer sur la gaîne de protection du câble de connexion, comme le montre la gure en haut à droite.
Remarque : Lors de la connexion du câble, conrmez le numéro de la borne des unités intérieures et extérieures. Un mauvais
branchement va endommager la commande du climatiseur, ou empêcher son fonctionnement.
3. Méthode de câblage de l'unité extérieure :
Ligne d'alimentation
Retirez le tableau de réparation de l'unité extérieure et desserrez le recouvrement de ls A. Passez ensuite le l sous tension, le
l neutre et le l de mise à la terre dans le recouvrement. Branchez-les dans le bornier correspondant. Après la connexion, serrez
le recouvrement de ls pour qu'il retrouve sa forme précédente. Câble de communication de l'unité intérieure.
Desserrez le recouvrement de ls. Passez le câble de communication dans le recouvrement de ls B puis branchez-le au bornier
correspondant. Après la connexion, serrez le recouvrement de ls B pour qu'il retrouve sa forme précédente.
Remarque : le câble de la ligne d'alimentation et le câble de communication sont à fournir par le client.
Branchez le l dont le dia-
mètre est identique, des
deux côtés de la borne
Ne branchez pas le l
dont le diamètre est
identique, du même
côté.
Ne branchez pas le
l dont les diamètres
sont différents
Méthode de câblage pour le
bornier à anneau
Bon pressage
Mauvais pressage
Bornier
Pinces de
pressage
Soupape d'arrêt liquide
Clé hexago-
nale
Fermer
Soupape
d'arrêt gaz
Capuchon de
soupape
13
–¨ 25.400
Câblage
Recouvrement de ls A
Recouvrement de
ls C
Recouvrement de ls B Bornier
Couvercle de soupape
Recouvrement
de ls A
Recouvrement
de ls C
Recouvrement de ls B
Recouvrement de ls D
Couvercle de soupape
Bornier
Recouvrement dels E
4. Méthode de câblage de l'unité extérieure
Desserrez le recouvrement de ls puis branchez la ligne d'alimentation et le câble de communication de l'unité intérieure au bor
-
nier correspondant.
Remarque :
Lorsque vous brancher la ligne d'alimentation à la borne d'alimentation, prenez garde aux points suivants :
Ne branchez pas une ligne d'alimentation dont les dimensions ne correspondent pas à l'extrémité du câble de connexion. Un
mauvais contact entraîne une production de chaleur.
Ne branchez pas une ligne d'alimentation dont les dimensions ne correspondent pas à l'extrémité du câble de mise à la terre. Un
mauvais contact affecte la protection.
Ne branchez pas la ligne d'alimentation à l'extrémité de connexion du câble de communication. Une mauvaise connexion va
endommager l'unité connectée.
5. Exemple de schéma de câblage.
Pour le schéma de câblage, veuillez vous référer au 5U34HS1 ERA
Placez les câbles de façon
à ce qu'aucune tension ne
soit appliquée sur l'orice
d'entretien ou sur d'autres
pièces structurelles.
Fixez fermement le câblage de la branche
en utilisant les 4 vis fournies, comme
le montre la gure. En le xant, assurez-
vous qu'aucune pression extérieure n'est
appliquée sur les bornes.
Utilisez les ls spéci-
és et branchez-les
de façon sûre.
14
Essai de fonctionnement
Avant de commencer l'essai, vériez que les travaux suivants ont bien été effectués.
1) Travaux de tuyauterie correctement effectués ;
2) Travaux de câblage correctement effectués ;
3) Bonne correspondance des unités intérieure et extérieure ;
4) Recharge de réfrigérant effectuée, si nécessaire.
Assurez-vous que toutes les soupapes d'arrêt sont bien ouvertes.
Contrôlez la tension fournie aux unités intérieure et extérieure. La tension doit être de 230V.
Contrôle des erreurs de câblage
Ce produit est capable de contrôler automatiquement les erreurs de câblage.
Allumez les 4 commutateurs DIP du petit tableau PC d'entretien de l'unité extérieure, comme indiqué sur la droite.
Puis mettez l'unité sous tension et remettez-la sous tension. Le système exécute le "Contrôle des erreurs de câ-
blage". Après 3 minutes de veille, l'unité lance automatiquement le contrôle du câblage.
30 à 50 minutes (selon le nombre d'unités installé dans le système) après le démarrage de l'unité, les Erreurs de
câblage s'afchent en voyants DEL (1 à 5).
Pendant cette exécution, le nombre numérique va afcher la fréquence de fonctionnement du compresseur (par
exemple 50 indique la fréquence actuelle de fonctionnement) puis les lettres "CH" (pour 'checking' ou contrôle).
Une fois le contrôle effectué, si le câblage est correct, le nombre numérique afche "0". Le nombre numérique afche "EC" (pour 'error
connection' ou erreur de connexion) et clignote en cas d'erreur dans le câblage.
Les voyants DEL de l'écran d'entretien indique le type d'erreur de câblage, comme le montre le tableau ci-dessous. Pour plus de détails
sur la lecture de l'écran DEL, veuillez vous référer au manuel d'entretien.
Si un contrôle automatique n'est pas possible, contrôlez le câblage et la tuyauterie de l'unité intérieure en consultant le manuel d'utilisation.
DEL 1 2 3 4 5 Message
Statut
ARRÊT Unité non connectée
TOUS clignotent
Contrôle automatique impossible, toutes
les connexions sont incorrectes
TOUS ALLUMÉS Toutes les unités sont bien branchées.
ALLUMÉ CLIGNOTE CLIGNOTE ALLUMÉ CLIGNOTE
ALLUMÉ : unité bien connectée CLI-
GNOTE : unité mal connectée, modica-
tion manuelle du câblage entre 2, 3 et 5
requise
ALLUMÉ CLIGNOTE CLIGNOTE ALLUMÉ ALLUMÉ
ALLUMÉ : unité bien connectée CLI-
GNOTE : unité mal connectée, modi-
cation manuelle du câblage entre 2, 3
requise
Un seul voyant DEL clignote Anormal
Essai de fonctionnement.
1) Si la température est inférieure à 16°C, il est impossible de tester le refroidissement avec la télécommande. De même, si la tempéra
-
ture est supérieure à 30°C, il est impossible de tester le chauffage.
2) Pour tester le refroidissement, réglez la température la plus basse sur 16°C. Pour tester le chauffage, réglez la température la plus
élevée sur 30°C.
3) Veuillez contrôler le fonctionnement du refroidissement et du chauffage de chaque unité, individuellement. Contrôlez également le fonc
-
tionnement simultané de toutes les unités intérieures.
4) Après avoir fait fonctionner l'unité pendant environ 20 minutes, vériez la température de sortie de l'unité intérieure.
5) Après avoir mis l'unité en arrêt, ou après la modication de son mode de fonctionnement, le système mettra environ 3 minutes avant de
redémarrer.
6) Pendant le fonctionnement en refroidissement, il est possible d'observer du gel sur l'unité intérieure ou ses conduits. Ceci est normal.
7) Faites fonctionner l'unité conformément au manuel d'utilisation. Expliquez le fonctionnement à vos clients en vous servant du manuel.
Écran numérique en sept parties
1) Lorsque l'unité est en marche, cet écran numérique afche la fréquence du compresseur. Par exemple,
"
" signie que la fréquence de fonctionnement du compresseur est 40 Hz, " " signie que la fréquence de
fonctionnement du compresseur est 108 Hz.
2) En cas de défaillance, l'écran numérique en sept partie clignote et afche certains nombres. Ce nombre cor-
respond à un code de défaillance. Par exemple, "
" qui clignote, correspond à la défaillance n° 32 c'est-à-dire à
une erreur de communication intérieure/extérieure.
Voyant DEL de communication
Le voyant DEL 5 vert signie qu'il y a 5 unités intérieure. Si un seul voyant DEL reste allumé, cela signie que l'unité
intérieure correspondante communique correctement avec l'unité extérieure. Si l'un des voyant DEL ne s'allume pas, cela signie qu'il n'y
a pas de communication intérieure/extérieure.
15
Dépannage
Temps à éclats
de lampe de
chronomètre
Temps à éclats de
lampe de course
Unité extérieure EEPROM défectueuse 1 15 2 1
IPM surintensité ou court circuit 2 16 2 2
Panne de communication entre Module et ECU
Câbles de communication brisés ou mal connectés."
418 2 4
Surcharge de module exploité 5 19 2 5
Module haute ou basse tension en courant continue (inférieur à 192V ou supérieur à 375V)" 6 1A 2 6
Surchauffe de température de décharge.Manque de réfrigérant, température ambiante trop élevée
ou PMVs bloqués. »
81C 2 8
Mauvais fonctionnement du moteur de ventilateur CC 9 1D 2 9
Dysfonctionnement du capteur de température de dégivrage 10 1E 3 0
Dysfonctionnement du capteur de la température d'aspiration de compresseur 11 1F 3 1
Dysfonctionnement du capteur de température ambiante 12 20 3 2
Dysfonctionnement du capteur de température de décharge de compresseur 13 21 3 3
Panne de communication entre l'unité intérieure & extérieure 15 23 3 5
Manque de fréon 16 36 3 6
Échec de commutation de valve à quatre voies 17 25 3 7
Surintensité de module/Échec de commutateur de module 18 26 3 8
Surcharge intérieure 20 28 4 0
Gel intérieur 21 29 4 1
Température de module trop élevé (protecteur contre surcharge) 23 2B 4 3
Surintensité de compresseur 24 2C 4 4
Surintensité d'entrée 25 2D 4 5
Réinitialisation MCU 26 2E 4 6
Module de courant pour détecter un mauvais fonctionnement du circuit 27 2F 4 7
Dysfonctionnement du capteur de température du liquide de tuyau pour unité intérieure A 28 30 4 8
Dysfonctionnement du capteur de température du liquide de tuyau pour unité intérieure B 29 31 4 9
Dysfonctionnement du capteur de température du liquide de tuyau pour unité intérieure C 30 32 5 0
Dysfonctionnement du capteur de température du liquide de tuyau pour unité intérieure D 31 33 5 1
Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure A 32 34 5 2
Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure B 33 35 5 3
Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure C 34 36 5 4
Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure D 35 37 5 5
Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure E 36 38 5 6
Dysfonctionnement du module de capteur de température 38 3A 5 8
Dysfonctionnement du capteur de température de condensation 39 3B 5 9
Dysfonctionnement du capteur de température du liquide pour unité intérieure E 40 3C 6 0
Dysfonctionnement du capteur de température de tuyauterie 41 3D 6 1
Déconnexion de système haute pression 42 3E 6 2
Déconnexion de système basse pression 43 3F 6 3
"Protection contre haute pression du système.Surabondance du réfrigérant, haute température de
condensation ou dysfonctionnement du moteur du ventilateur
44 40 6 4
"Protection contre la basse pression du système. Pénurie de réfrigérant, basse température de dé
givrage ou dysfonctionnement du moteur du ventilateur.
45 41 6 5
Dysfonctionnement du capteur de température de module 46 42 6 6
Cassette et code d'erreur extérieur
pour affichage intérieure convertible
utilisent le chronomètre et la lampe
de course
Affichage de
commande câ
blée
Affichage
LED exté
rieur
Raisons possibles
Adresse : No.1 Haier Road, Hi-tech Zone.Qingdao 266101 P.R.Chine
Contacts : Tél. : +86-532-8893-6943 ; Télécopie +86-532-8893-6999
Site Internet : www.haier.com
INSTALLATIONSANLEITUNG FÜR
MULTI-SPLIT-KLIMAANLAGE
Inhalt
Sicherheitsvorkehrungen ------------------- 3
Zubehör
--------------------------------------- 4
Vorsichtsmaßnahmen bei der Wahl
des Standortes -------------------------------- 4
Installationsabbildungen der Innen-
und Außengeräte
----------------------------- 5
Vorsichtsmaßnahmen bei der
Installation -------------------------------------- 7
Installationsanleitung für Außengerät
---- 7
Beschränkungen bei der Installation
----- 7
Verrohrung des Kältemittels
--------------- 7
Abpumpbetrieb
------------------------------12
Verdrahtung -----------------------------------12
Testlauf -----------------------------------------14
Fehlerbehebung
-----------------------------15

Lesen Sie dieses Handbuch vor der Inbetriebnahme bitte sorgfältig durch.
Bewahren Sie diese Anleitung für eine spätere Bezugnahme gut auf.
Deutsch
ÜBEREINSTIMMUNG MIT EUROPÄ-
ISCHEN VORSCHRIFTEN FÜR DIE
MODELLE
CE
Alle Produkte stimmen mit folgenden europäischen Bestimmungen
überein:
- Niederspannungsrichtlinie 73/23/EWG
- Niederspannungsrichtlinie 2006/95/EWG
- Elektomagnetische Verträglichkeit 89/336/EWG
- Elektomagnetische Verträglichkeit 2004/108/EWG
ROHS
Die Produkte stimmen mit den Anforderungen der Richtlinie
2002/95/EWG des Europäischen Parlaments und des Rates zur
Beschränkung der Verwendung bestimmter gefährlicher Stoffe in
Elektro- und Elektronikgeräten (EG-RoHS-Richtlinie) überein.
WEEE
Gemäß Richtlinie 2002/96/EG des Europäischen Parlaments infor-
mieren wir den Kunden hiermit über die Entsorgungsvorschriften
für Elektro- und Elektronikgeräte.
ENTSORGUNGSVORSCHRIFTEN:
Ihr Klimaanlageprodukt ist mit diesem Symbol
gekennzeichnet. Dies bedeutet, dass Elektro-
und Elektronikprodukte nicht zusammen mit
dem unsortierten Hausmüll entsorgt werden
dürfen. Versuchen Sie nicht, das System zu
demontieren: Die Demontage des Klimaanlagesystems, die
Handhabung von Kältemittel, Öl und anderer Teile muss von
einem qualifizierten Installateur gemäß einschlägiger lokaler
und nationaler Vorschriften vorgenommen werden. Klima
-
anlagen müssen in einer speziellen Aufbereitungsanlage für
Wiederverwendung, Recycling und Rückgewinnung auf-
bereitet werden. Durch Sicherstellung einer sachgemäßen
Entsorgung dieses Produkts tragen Sie dazu bei, potentiell
negative Auswirkungen auf die Umwelt und die menschliche
Gesundheit zu verhindern. Weitere Auskunft erteilt Ihnen
gerne der Installateur oder Ihre Behörde vor Ort. Die Batte-
rie muss aus der Fernbedienung hergenommen und gemäß
einschlägiger lokaler und nationaler Vorschriften getrennt
entsorgt werden.
WICHTIGE INFORMATIONEN ZUM
VERWENDETEN KÄLTEMITTEL
Dieses Produkt enthält fluorierte Treibhausgase, die unter das
Kyoto-Protokoll fallen. Nicht in die Atmosphäre ablassen.
Kältemitteltyp: R410A
GWP*-Wert: 1975
GWP=Treibhauspotenzial
Bitte mit dokumentenechter Tinte ausfüllen:
• 1 Die werkseitige Kältemittelladung des Produkts
• 2 Die zusätzliche Menge an Kältemittel, die im Installationsbe
-
reich nachgefüllt wurde, und
• 1+2 Die gesamte Kältemittelladung auf dem mit dem Produkt
versehenen Kältemittelladungsetikett. Das ausgefüllte Etikett muss
neben dem Ladeport des Produkts aufgeklebt werden (z. B. auf der
Innenseite des Sperrventildeckels).
A Enthält fluorierte Treibhausgase, die unter das Kyoto-Protokoll
fallen
B Werkseitige Kältemittelladung des Produkts: Siehe Typenschild
des Geräts
C Zusätzliche Menge an Kältemittel, die im Installationsbereich
nachgefüllt wurde
D gesamte Kältemittelladung
E Außengerät
F Kältemittelzylinder und Anschlussstück zum Nachfüllen
Haier Industrial Park, No.1 Haier Road, Qingdao, VR-China
Enthält uorierte Treibhausgase, die unter
das Kyoto-Protokoll fallen
Kg
Kg
Kg
Sicherheitsvorkehrungen
Lesen Sie diese Sicherheitsvorkehrungen sorgfältig durch, um eine sachgemäße Installation zu gewährleisten.
In diesem Handbuch sind Sicherheitsvorkehrungen in die Abschnitte WARNUNG und VORSICHT unterteilt.
Achten Sie darauf, alle folgenden Sicherheitsvorkehrungen zu beachten: Sie sind alle wichtig zur Gewährleistung der Sicherheit.
WARNUNG Nichtbefolgung einer WARNUNG hat höchstwahrscheinlich schwerwiegende Folgen wie Tod oder schwere Verletzung.
VORSICHT Nichtbefolgung einer VORSICHTSMASSNAHME kann in einigen Fällen schwerwiegende Folgen haben.
Folgende Sicherheitssymbole werden insgesamt in diesem Handbuch verwendet:
Sie müssen diese Anweisungen
unbedingt befolgen
.
Sie müssen das Gerät auf jeden
Fall erden.
Nie versuchen.
VORSICHT
Installieren Sie die Klimaanlage nicht an einem Ort, an dem die Gefahr des Kontakts mit brennbaren Gasen bestehen könnte.
Wenn Gas ausströmt und sich um das Gerät ansammelt, könnte es einen Brand entfachen.
Verlegen Sie das Abussrohr gemäß den Anweisungen in diesem Handbuch.
Eine unsachgemäße Rohrverlegung kann zu einer Überschwemmung führen.
Ziehen Sie die Ringmutter gemäß der angegebenen Methode an, z. B. mit einem Drehmomentschlüssel.
Wird die Ringmutter zu fest angezogen, könnte sie nach längerem Einsatz einreissen, was dazu führt, das Kältemittel ausläuft.
Sorgen Sie unbedingt für geeignete Maßnahmen, die verhindern, dass das Außengerät als Unterschlupf für kleine Tiere verwendet wird.
Kleine Tiere, die mit elektrischen Teilen in Kontakt kommen, können Betriebsstörungen, Rauch oder Brand verursachen. Belehren Sie bitte den Kunden, den Bereich um das
Gerät sauber zu halten.
3
Überprüfen Sie das Gerät nach vollständiger Installation auf Installationsfehler. Geben Sie dem Benutzer geeignete Anweisungen zur
Verwendung und Reinigung des Geräts gemäß der Bedienungsanleitung.
WARNUNG
Die Installation sollte vom Händler oder einem Fachmann vorgenommen werden.
Bei falscher Installation kann Wasser auslaufen, Stromschlag oder Brand die Folge sein.
Installieren Sie die Klimaanlage gemäß den Anweisungen in diesem Handbuch.
Bei unvollständiger Installation kann Wasser auslaufen, Stromschlag oder Brand die Folge sein.
Achten Sie darauf, die mitgelieferten oder vorgegebenen Installationsteile zu verwenden.
Bei Verwendung anderer Teile könnte sich das Gerät lösen, ein Wasserleck, ein Stromschlag oder ein Brand entstehen.
Installieren Sie die Klimaanlage auf einer soliden Unterlage, die das Gewicht des Geräts tragen kann.
Bei unzureichender Unterlage oder unvollständiger Installation könnten Verletzungen entstehen, wenn das Gerät von der Unterlage herunterfällt.
Elektrische Arbeiten sollten gemäß der Installationsanleitung und den nationalen Vorschriften für elektrische Verdrahtungen oder den
Praxisleitfäden vorgenommen werden.
Eine unzureichende Kapazität oder eine unvollständige elektrische Verdrahtung kann zu Stromschlag oder Brand führen.
Verwenden Sie auf jeden Fall eine festgeschaltete Stromversorgung. Verwenden Sie nie eine Stromversorgung, mit der auch andere
Geräte versorgt werden.
Verwenden Sie für die Verdrahtung ein Kabel, das lang genug ist, die gesamte Distanz ohne Zwischenanschlüsse zu überbrücken.
Verwenden Sie keine Verlängerungsschnur. Legen Sie keine anderen Lasten an die Stromversorgung, verwenden Sie eine festge
-
schaltete Stromversorgung.
(Andernfalls kann es zu unnormaler Hitze, Stromschlag oder Brand kommen.)
Verwenden Sie vorgegebene Drahttypen für die elektrischen Verbindungen zwischen den Innen- und Außengeräten.
Klemmen Sie die Verbindungsdrähte fest, so dass die Anschlussleisten keiner äußeren Zugkraft ausgesetzt sind. Bei unvollständigen Anschlüssen oder Klemmvorrichtungen
kann sich die Anschlussleiste überhitzen oder in Brand geraten.
Achten Sie nach Verbindung der Anschluss- und Versorgungsleitungen darauf, dass sie so verlegt werden, dass sie keine übermäßige
Kraft auf elektrische Abdeckungen oder Blenden ausüben.
Installieren Sie die Abdeckungen über die Drähte. Bei unvollständiger Installation der Abdeckung kann sich die Anschlussleiste überhitzen, Stromschlag oder Brand die Folge sein.
Ist während der Installation Kältemittel ausgetreten, müssen Sie das Zimmer lüften.
(Das Kältemittel erzeugt ein giftiges Gas, wenn es Feuer ausgesetzt wird.)
Prüfen Sie nach vollständiger Installation, dass das Kältemittel nicht ausläuft.
(Das Kältemittel erzeugt ein giftiges Gas, wenn es Feuer ausgesetzt wird.)
Bei Installation oder Verlegung des Systems dürfen Sie keine anderen Stoffe, z. B. Luft, in den Kältemittelkreis einführen als das vorge-
gebene Kältemittel (R410A).
(Das Vorhandensein von Luft oder anderer Fremdstoffe im Kältemittelkreis kann zu einem unnormalen Druckanstieg oder zum Aufplatzen und damit zu Verletzungen führen.)
Stoppen Sie während des Abpumpens den Kompressor, bevor Sie die Rohrleitung für das Kältemittel abnehmen.
Ist der Kompressor während des Abpumpens weiterhin in Betrieb und das Absperrventil geöffnet, wird Luft eingesaugt, was zu einem unnormalen Druck im Gefrierzyklus führt
und ein Aufplatzen des Rohres und sogar Verletzungen verursacht.
Sie müssen das Gerät auf jeden Fall erden. Erden Sie das Gerät nicht über eine Energieversorgungsleitung, den Blitzableiter
oder den Schutzleiter eines Telefons.
Ist die Erdung unzureichend, kann ein Stromschlag oder ein Brand die Folge sein. Ein Starkstromstoß von einem Blitz oder anderen Quellen kann die Klimaanlage beschädigen.
Sie müssen auf jeden Fall einen Fehlerstromschutzschalter installieren.
Wird kein Fehlerstromschutzschalter installiert, besteht die Gefahr eines Stromschlags oder eines Brandes.
4
Zubehör
Beigefügtes Zubehör für Außengerät:
Nr. Zeichnung Name des Teils Anzahl Hinweis
1 Abussknie
1
3
2
Gummipolster 4
3
Klammer
1
3
4
Adapter (3/8
1/2) 1
5
Adapter(1/2
3/8) 1
Vorsichtsmaßnahmen bei der Wahl des Standortes
1) Wählen Sie eine Stelle, die stark genug ist, das Gewicht und die Vibrationen des Geräts zu tragen, und wo das Betriebs-
geräusch nicht verstärkt wird.
2) Wählen Sie eine Stelle, wo abgegebene Heißluft oder das Betriebsgeräusch weder die Nachbarn noch den Benutzer
stört.
3) Vermeiden Sie Orte wie Schlafzimmer und ähnliche Zimmer, wo das Betriebsgeräusch sich nicht störend auswirkt.
4) Es muss genügend Platz vorhanden sein, das Gerät zum Aufstellungsort zu tragen und von ihm wegzutragen.
5) Es muss ausreichend Platz für einen Luftdurchlass vorhanden und der Luftein- und -auslass darf nicht blockiert sein.
6) Es dürfen sich keine entzündbaren Gase in der Nähe des Aufstellungsortes benden.
Stellen Sie das Gerät so auf, dass weder Betriebslärm noch Heißluft die Nachbarn stört.
7) Installieren Sie Geräte, Stromleitungen und Leitungen zwischen den Geräten in einem Abstand von mindestens 3 Metern
von Fernseh- und Radiogeräten. Auf diese Weise werden Bild- und Tonstörungen vermieden. (Je nach Radiowellen könnten
Störungen auch bei einem Abstand über 3 Meter möglich sein.)
8) In Küstengebieten oder anderen Orten mit salzhaltiger Luft oder schwefelhaltigen Gasen kann sich die Lebenszeit der
Klimaanlage aufgrund von Korrosion verkürzen.
9) Da Abwasser aus dem Außengerät läuft, stellen Sie keine Gegenstände unter das Gerät, die nicht der Feuchtigkeit aus-
gesetzt werden dürfen.
HINWEIS:
Darf nicht hängend von der Decke oder gestapelt installiert werden.
Setzen Sie die Klimaanlage bei niedriger Außentemperatur
in Betrieb, beachten Sie bitte die folgenden Anweisungen.
1) Um Windeinwirkung zu vermeiden, installieren Sie das
Außengerät so, dass seine Ansaugseite zur Wand weist.
2) Installieren Sie das Außengerät nie an einer Stelle, wo
seine Ansaugseite direkt dem Wind ausgesetzt ist.
3) Um Windeinwirkung zu vermeiden, wird die Anbringung
einer Ablenkplatte auf der Luftauslassseite des Außengeräts
empfohlen.
4) In Regionen mit starkem Schneefall wählen Sie bitte eine
Installationsstelle, wo der Schnee nicht das Gerät beein-
trächtigt.
VORSICHT
Errichten Sie eine große
Abdeckhaube.
Errichten Sie einen Sockel.
Installieren Sie das Gerät so hoch
über den Boden, dass es nicht vom
Schnee begraben werden kann.
5
Installationsabbildungen der Innen- und Außengeräte
1. Verbinden Sie nicht das eingebettete Abzweigrohr und das Außengerät, wenn Sie nur Rohrarbeiten ohne angeschlossenes
Innengerät ausführen, um später ein weiteres Innengerät hinzuzufügen. Achten Sie darauf, dass weder Schmutz noch Feuchtigkeit
in eine der beiden Seiten des eingebetteten Abzweigrohrs gelangt.
2. Es ist nicht möglich, das Innengerät nur für ein Zimmer anzuschließen.
Besteht die Gefahr, dass das Gerät umkippen oder herunterfallen könnte, befestigen Sie es mit Fundamentschrauben, Drähten oder anderen Mitteln.
Ist am Aufstellungsort kein guter Abuss vorhanden, stellen Sie das Gerät auf einen ebenen Montagesockel (oder einen Kunststoffsockel).
Installieren Sie das Außengerät auf einer waagerechten Ebene. Andernfalls könnte Wasser auslaufen oder sich ansammeln.
Links
Mehr als 5 cm
Anordnung der Rohrrichtungen
Hinten links
Hinten rechts
Rechts
Unterhalb
Mehr als 10
cm
Mehr
als
10 cm
Schneiden Sie das Wärmeisolierrohr auf eine pas-
sende Länge zu und umwickeln Sie es mit Isolier-
band, um zu sicherzustellen, dass die Schnittlinie
des Isolierrohrs komplett isoliert ist.
Mehr als
60
cm
Beachtung muss
dem aufsteigenden
Abussschlauch
geschenkt werden
Mehr als 10
cm
Mehr
als
25
cm
Umwickeln Sie das Isolierrohr von unten bis
oben mit dem Abdeckband.
Siehe bitte 4U30HS1ERA für Installationsabbildung
6
Installationsabbildungen der Innen- und Außengeräte
Vorsichtshinweise für den Anschluss
Modell
Anschlusspriorität
zwischen Innengerät und
höherem Absperrventil
von unten nach oben
Bei 1 Innengerät ist das
prioritäre Absperrventil
C D E
Bei 2 Innengeräten
sind die prioritären
Absperrventile
C B D C E D
Bei 3 Innengeräten
sind die prioritären
Absperrventile
C B A D C B E D C
Bei
5
Innengeräten
sind
die
prioritären
Absperrventile
E
D
C
B A
Hinweis:
Für
eine
bessere
Ölrückkehr
und
ein
zuverlässigeres
System
gehen
Sie
beim
Anschluss
des
Innengeräts
bitte
gemäß
obiger
Beschreibung
vor.
Bei 4 Innengeräten
sind die prioritären
Absperrventile
D C B A E D C B
7
Vorsichtsmaßnahmen bei der Installation
Prüfen Sie die Stärke und Ebenmäßigkeit des Installationsbodens, so dass das Gerät nach der Installation weder Vibrationen
noch Lärm während des Betriebs erzeugt.
Befestigen Sie das Gerät gemäß der Fundamentzeichnung mit Fundamentschrauben. (Dazu benötigen Sie vier Sets von M8
oder M10 Fundamentschrauben, Muttern und Unterlegscheiben, die alle im Handel erhältlich sind.)
Am besten drehen Sie die Fundamentschrauben so weit ein, bis sie 20 mm vom Fundament abstehen.
Beschränkungen bei der Installation
1. Vorsichtsmaßnahmen bei der Installation
Prüfen Sie die Stärke und Ebenmäßigkeit des Installationsbodens, so dass das Gerät nach der Installation weder Vibrationen
noch Lärm während des Betriebs erzeugt.
• Befestigen Sie das Gerät gemäß der Fundamentzeichnung mit Fundamentschrauben.
• Am besten drehen Sie die Fundamentschrauben so weit ein, bis sie 20 mm vom Fundament abstehen.
2. Wahl eines Standortes für die Installation der Innengeräte
In der folgenden Liste ist die maximal zulässige Länge des Kältemittelrohrs und der maximal zulässige Höhenunterschied zwi
-
schen den Außen- und Innengeräten angegeben. (Je kürzer das Kältemittelrohr ist, desto besser ist die Leistung. Machen Sie
den Rohranschluss so kurz wie möglich. Die kürzeste zulässige Länge pro Zimmer beträgt 3 m.)
Außengerätkapazitätsklasse
Rohrleitung
zu
jedem
Innengerät
max.
Rohrgesamtlänge
zwischen
allen
Geräten
max.
Installationsanleitung für Außengerät
An Stellen, an denen eine Wand oder eine andere Behinderung den Pfad des Luftein- oder -auslasses des Geräts behindert,
halten Sie sich bitte an die folgenden Hinweise zur Installation.
Für jede der nachstehenden Installationsmethoden sollte die Wandhöhe auf der Abluftseite maximal 1200 mm betragen.
Seitenansicht
Mehr als 50
Wand auf einer Seite
Mehr als 300
1200
oder
darunter
Seitenansicht
Wand auf beiden Seiten
Mehr
als 100
Mehr
als 300
Mehr
als 100
Mehr
als 50
Wand auf drei Seiten
Mehr
als 50
Mehr als 150
Mehr als 300
Seitenansicht
max.
max.
max.
max.
max.
max.
8
Beschränkungen bei der Installation
Abussknie
Verrohrung des Kältemittels
1. Installation des Außengeräts
1) Beziehen Sie sich für die Installation des Außengeräts auf die Abschnitte "Vorsichtsmaßnahmen bei der Wahl des Stand
-
ortes" und "Installationsabbildungen der Innen- und Außengeräte".
2) Sind Arbeiten am Abuss erforderlich, beachten Sie die folgenden Schritte.
2. Arbeiten am Abuss
1) Verwenden Sie einen Ablasshahn für den Abuss.
2) Wird der Abussanschluss vom Montagesockel oder der Bodenäche verdeckt, bringen Sie zusätzlich Fußsockel in einer
Höhe von mindestens 30 mm unter den Füßen des Außengeräts an.
3) Bringen Sie in kalten Regionen keinen Abussschlauch an das Außengerät an. (Andernfalls könnte das Abusswasser
gefrieren und die Heizleistung beeinträchtigen.)
Schlauch
Abussknie
Schlauch
Innengerät
Niveauun-
terschied:
max. 15m
Außengerät
Niveauun-
terschied:
max. 7,5 m
Wenn das Außengerät höher steht als die Innengeräte.
Niveauun-
terschied:
max. 15m
Niveauun-
terschied:
max. 7,5 m
Innengerät
Außengerät
Wenn das Außengerät höher steht als die Innengeräte.
(Niedriger als ein oder mehrere Innengeräte.)
Innengerät
Außengerät
Wenn das Innengerät höher steht als die Außengeräte.
Niveauun-
terschied:
max. 15m
Niveauun-
terschied:
max. 7,5 m
9
Verrohrung des Kältemittels
3. Verrohrung des Kältemittels
1) Richten Sie die Mitten beider Bördeln miteinander aus und ziehen Sie die Ringmuttern 3 oder 4 Umdrehungen mit der Hand an. Ziehen
Sie sie dann mit einem Drehmomentschlüssel fest an. Ziehen Sie die Ringmuttern mithilfe von Drehmomentschlüsseln an, um die Ring
-
muttern nicht zu beschädigen, wodurch Gas entweichen könnte.
Anziehdrehmoment für Ringmutter
Ringmutter für
6,35 14,2-17,2 Nm (144-175 kgf.cm)
Ringmutter für 9,52 32,7-39,9 Nm (333-07 kgf.cm)
Ringmutter für
12,7 49,5-60,3 Nm (505-615 kgf.cm)
Ringmutter für 15,88 61,8-75,4 Nm (630-769 kgf.cm)
Anziehdrehmoment für Ventilkappe
Anziehdrehmoment für Abdeckung
der Wartungsöffnung
Flüssigkeitsrohr 26,5-32,3 Nm (270-330 kgf.cm)
10,8-14,7 Nm (110-150 kgf.cm)
Gasleitung 48,1-59,7 Nm (490-610 kgf.cm)
2) Um ein Gasleck zu vermeiden, tragen Sie Kühlmittelöl innen und außen auf der Bördelung auf. (Verwenden Sie Kühlmittelöl für R410A.)
4. Beseitigung von Luft und Überprüfung auf Gasleck
Nach den Rohrarbeiten muss die Luft beseitigt und nach ausströmendem Gas gesucht werden.
1) Geben Sie keine anderen Stoffe als das vorgegebene Kältemittel (R41OA) in den Kühlzyklus.
2) Wenn Kältemittelgas ausströmt, lüften Sie das Zimmer möglichst früh und möglichst lange.
3) R410A und auch andere Kältemittel müssen immer aufgefangen und dürfen nie in die Umgebung abgelassen werden.
4) Verwenden Sie eine Vakuumpumpe ausschließlich für R41OA. Wenn Sie dieselbe Vakuumpumpe für andere Kältemittel verwenden,
kann die Vakuumpumpe oder das Gerät beschädigt werden.
Wenn Sie Kältemittel bemischen möchten, beseitigen Sie die Luft aus den ltemittelrohren und dem Innengerät mit einer Vakuum-
pumpe und füllen Sie dann zusätzliches Kältemittel nach.
Betätigen Sie die Absperrventilspindel mit einem Sechskantschlüssel (4 mm).
Alle Kältemittelrohrverbindungen müssen mit einem Drehmomentschlüssel mit dem vorgegebenen Anziehdrehmoment fest angezogen
werden.
Verbinden Sie die Überhangseite des Befüllungsschlauchs (der vom Anschlussstück der Messgeräts kommt) mit der Wartungsöffnung
des Gasabsperrventils.
Öffnen Sie ganz das Unterdruckventil des Anschlussstücks vom Messgerät (Lo) und schließen Sie ganz sein Überdruckventil (Hi).
(Hiernach braucht das Überdruckventil nicht betätigt zu werden.)
Setzen Sie die Vakuumpumpe an. Achten Sie darauf, dass der Verbunddruckmesser auf -0,1 MPa (-76 cmHg) steht. Es wird ein Ab-
pumpen von mindestens 1 Stunde empfohlen.
Schließen Sie das Unterdruckventil des Anschlussstücks vom Messgerät (Lo) und stoppen Sie die Vakuumpumpe.
(Warten Sie 4-5 Minuten und vergewissern Sie sich, dass sich die Messnadel des Anschlussstücks nicht zurücksetzt.
Setzt sie sich dennoch zurück, könnte Feuchtigkeit oder ein Leck bei den Verbindungsteilen vorhanden sein. Überprüfen Sie alle Ver
-
bindungen, ziehen Sie die Muttern neu fest an und wiederholen Sie die Schritte 2-4.)
Entfernen Sie die Kappen vom Flüssigkeitsabsperrventil und vom Gasabsperrventil.
Drehen Sie die Spindel des Flüssigkeitsabsperrventils mit einem Sechskantschlüssel 90 Grad gegen den Uhrzeigersinn, um das Ventil
zu öffnen. Schließen Sie es nach 5 Sekunden und suchen Sie nach Gaslecks.
Suchen Sie mittels Seifenlauge nach Gaslecks an den Bördelungen des Innen- und des Außengeräts und den Ventilspindeln. Wischen
Sie nach Prüfung die gesamte Seifenlauge weg.
Trennen Sie den Befüllungsschlauchs von der Wartungsöffnung des Gasabsperrventils und öffnen Sie dann ganz die Flüssigkeits- und
Gasabsperrventile. (Drehen Sie die Ventilspindel nur bis zu ihrem Anschlag und nicht darüber hinaus.)
Ziehen Sie die Ventilkappen und die Wartungsöffnungkappen der Flüssigkeits- und Gasabsperrventile mit einem Drehmomentschlüs-
sel mit den vorgegebenen Anziehdrehmomenten fest an. Details hierzu siehe "3 Verrohrung des Kältemittels" auf Seite 6.
Tragen Sie hier Kühlmittelöl auf
Drehmomentschlüssel
Schlüssel
Rohrverbindung
Konusmutter
WARNUNG
10
Verrohrung des Kältemittels
5. Nachfüllen von Kältemittel
Verwenden Sie das Kältemittel, das auf dem Typenschild des Geräts angegeben ist.
Vorsichtsmaßnahmen beim Nachfüllen von R410A
Füllen Sie über das Flüssigkeitsrohr in üssiger Form nach.
Handelt es um ein Kältemittelgemisch und füllen Sie es in Gasform nach, kann sich die Zusammensetzung des Kältemittels
ändern und den Normalbetrieb verhindern.
1) Prüfen Sie vor dem Nachfüllen, ob ein Siphon an dem Zylinder angebracht ist. (Er sollte mit "Siphon zum Nachfüllen von
Flüssigkeit angebracht" oder Ähnlichem beschriftet sein.)
2) Achten Sie auf Verwendung der R41OA-Werkzeuge, um den richtigen Druck zu erhalten, und verhindern Sie, das Fremd
-
objekte eindringen.
6. Nachfüllen von Kältemittel
1) Dieses System verwendet das Kältemittel R410A.
2) Füllen Sie das Kältemittel in einer Menge von 20 g pro
Meter nach, wenn die Gesamtrohrlänge den Standardwert
überschreitet, aber achten Sie darauf, dass die Gesamt
-
rohrlänge für die Flüssigkeit nicht den Maximalwert über-
schreitet.
Hinweise:
1) Für den Betrieb dieses Produkts brauchen Sie keine Adresse einzustellen. Doch müssen die UN-Drähte der Innen- und
Außengeräte zueinander passen, denn sonst kommt es zu Kommunikationsfehlern.
2) Einstellung des ruhigen Betriebsverlaufs. Setzen Sie den DIP-Schalter "8" von SW5 auf ON (Ein), reduziert sich das Be
-
triebsgeräusch des Systems; allerdings verringert sich dann auch leicht die maximale Betriebsleistung.
3) Ändern Sie nicht die Einstellungen der anderen Switche, denn falsche Einstellungen können das System beschädigen
oder andere Betriebsstörungen verursachen.
7. Vorsichtsmaßnahmen beim Verlegen des Kältemittelrohrs
Sicherheitshinweise für die Rohrhandhabung
1) Schützen Sie das offene Ende des Rohrs vor Schmutz und Feuchtigkeit.
2) Alle Rohrverbiegungen müssen so vorsichtig wie möglich ausgeführt werden. Verwenden Sie zum Verbiegen ein Rohr
-
biegewerkzeug. (Der Biegeradius sollte 30 bis 40 mm oder mehr betragen.)
Wahl von Kupfer- und Wärmeisoliermaterialien
Beachten Sie Folgendes bei der Verwendung von handelsüblichen Kupferrohren und dem Zubehör:
1) Isoliermaterial: Polyäthylen-Schaumstoff (PE)
Wärmeübergangszahl: 0,041 bis 0,052 W/mK (0,035 bis 0,045 kcal/mh°C)
Die Außentemperatur der Gasrohrleitung des Kältemittels erreicht maximal 110°C.
Wählen Sie Wärmeisoliermaterialien, die dieser Temperatur standhalten.
2) Gas- und Flüssigkeitsleitung müssen auf jeden Fall isoliert werden, wobei die folgenden Isoliermaße beachtet werden
müssen.
Außengerät
Standardlgesamtän-
ge der Flüssigkeits-
leitung
Max. Gesamtänge der
Flüssigkeitsleitung
Gasleitung Isolierung der Gasleitung
Außendurchm.: 9,52 mm,
12,7 mm
Dicke: 0,8 mm
Innendurchm.:12-15 mm, 12,7
mm
Dicke: Min. 13mm
Flüssigkeitsrohr Isolierung des Flüssigkeitsrohrs
Außendurchm.: 6,35 mm
Dicke: 0,8 mm
Innendurchm.: 18-10 mm
Dicke: Min. 10 mm
Befüllen Sie einen Zylinder mit angebrachtem Siphon
Stellen Sie den Zylinder zum Befüllen
aufrecht hin.
Da sich im Innern ein Ansaugrohr bendet,
braucht der Zylinder zum Befüllen mit Flüs
-
sigkeit nicht auf den Kopf gedreht werden.
Befüllen anderer Zylinder
Drehen Sie den Zylinder zum Befüllen
auf den Kopf.
11
Rohrarbeiten für Kältemittel
3) Verwenden Sie getrennte Wärmeisolierrohre für das Gas- und das Flüssigkeitskältemittelrohr.
8. Zuschneiden und Bördeln der Rohre
Rohre werden mit einem Rohrschneider zugeschnitten und Grate müssen entfernt werden.
Nach dem Einfügen der Ringmutter wird gebördelt.
Rohr
Rohrdurchmes-
ser
Größe A
(mm)
Flüssig-
keitsseite
6,35mm (1/4") 0.8-1.5
Gasseite
9,52mm (3/8")
1.0-1.5
12,7 mm (1/2")
1.0-1.5
9. Abuss
Installieren Sie den Abussschlauch bitte so, dass er auf jeden Fall abwärts geneigt ist. Installieren Sie den Abuss bitte
nicht so, wie nachstehend abgebildet ist.
Gießen Sie Wasser in die Ablaufwanne des Innengeräts und überzeugen Sie sich davon, dass der Abuss sachgemäß
nach außen führt.
Sollte sich der angebrachte Abussschlauch in einem Zimmer benden, müssen Sie ihn wärmeisolieren.
1) Tragen Sie kein Mineralöl auf die Bördelung auf.
2) Achten Sie darauf, dass das Mineralöl nicht in das System eindringt, denn dadurch verkürzt sich die Lebenszeit der Geräte.
3) Verwenden Sie keine Rohrleitungen, die bereits für frühere Installationen verwendet wurden. Verwenden Sie nur die Tei-
le, die Sie zusammen mit dem Gerät erhalten haben.
4) Installieren Sie nie einem Entfeuchter an diesem R41OA-Gerät, um nicht seine Lebenszeit zu verkürzen.
5) Das Trockengut könnte sich auösen und das System beschädigen.
6) Unvollständige Bördelung kann zu ausströmendem Kältemittelgas führen.
Verdrahtung zwischen den Geräten
Gasleitung
Flüssigkeitsrohr
Isolierung der
Gasleitung
Isolierung des
Flüssigkeitsrohrs
Abdeckband
Abussschlauch
Prüfen Sie
Innenäche der
Bördelung muss
fehlerfrei sein.
Das Rohrende muss in
einem perfekten Kreis
gleichmäßig gebördelt
sein.
Die Ringmutter muss
angebracht sein.
Regen
Setzen Sie
unbedingt
eine Kappe
auf.
Ist keine Bördel
-
kappe verfügbar,
verschließen Sie die
Bördelöffnung mit
einem Band, damit
kein Schmutz oder
Wasser eindringen
kann.
Wand
Schneiden Sie genau
rechtwinklig zu.
Grate entfernen
Genau in nachstehender Position einsetzen.
Bördelwerkzeugform
Bördelwerkzeug für R410A Herkömmliches Bördelwerkzeug
Mit Greifer Mit Greifer (starrr)
Mit Flügelmutter
(traditionell)
0-0,5mm 1,0-1,5mm 1,5-2,0 mm
Richtig Falsch
Schief Bördel beschädigt
Angeris-
sen
Unvoll-
ständig
Zu weit nach
außen
WARNUNG
Bördelwerkzeugform
Wird in der Mitte
zu hoch.
Das Ende ist in Wasser
eingetaucht
Abstand zum Boden ist
zu gering.
Schlechter Geruch steigt aus
einem Abwassergraben auf.
Ist wellig.
Unter 5
cm
12
Abpumpbetrieb
Zum Schutz der Umwelt müssen Sie abpumpen, wenn Sie das Gerät umstellen oder entsorgen.
1) Entfernen Sie die Ventilkappen vom Flüssigkeitsabsperrventil und vom
Gasabsperrventil.
2) Nehmen Sie eine Zwangskühlung vor.
3) Schließen Sie das Flüssigkeitsabsperrventil nach fünf bis zehn Minuten
mit einem Sechskantschlüssel.
4) Schließen Sie das Gasabsperrventil nach zwei bis drei Minuten und
stoppen Sie die Zwangskühlung.
Verdrahtung
1. Elektrische Verdrahtung
Die Klimaanlage muss an einen Sonderstromkreis angeschlossen werden, wobei die Verdrahtung von einem qualizierten Elek
-
triker gemäß den im nationalen Standard vorgegebenen Verdrahtungsvorschriften ausgeführt werden muss.
Schutzleiter und Nullleiter müssen strikt voneinander getrennt werden. Der Anschluss des Nullleiters an den Schutzleiter ist
falsch.
Es muss ein Fehlerstromschutzschalter installiert werden.
Bei allen elektrischen Drähten muss es sich um Kupferdrähte handeln. Stromversorgung: 1PH, 220-230V-, 50Hz.
Die Netzleitung wird als Y-Anschluss verdrahtet. Ist die Netzleitung beschädigt, muss sie vom Hersteller, seinem Reparaturdienst
oder einer ähnlich qualizierten Person ersetzt werden, um keinen Stromschlag zu verursachen. Die Anschlussleitung muss ab-
geschirmt sein.
Sicherung: T3.15A250VAC T16A250VAC (beziehen Sie sich bitte auf den Schaltplan des Außengeräts)
Beziehen Sie sich bitte auf den Schaltplan hinsichtlich der zu ersetzenden Sicherung.
2. Verdrahtungsmethode
Verdrahtungsmethode bei kugelförmigen Anschlussleisten: Anschlussdrähte werden anhand der
rechts abgebildeten Methode mit kugelförmigen Anschlussleisten verbunden: Entfernen Sie die An
-
schlussschraube, stecken Sie die Schraube durch den Ring am Drahtende, schließen Sie dann die An
-
schlussleiste und ziehen Sie die Schraube fest an. Verdrahtungsmethode bei geraden Anschlussleisten:
Verdrahtungsmethode für Anschlussdraht ohne kugelförmige Anschlussleisten: Lösen Sie die Verbin
-
dungsschraube, stecken Sie ein Ende des Anschlussdrahts ganz in die Anschlussleiste und ziehen
Sie dann die Schraube an. Ziehen Sie den Draht ein wenig heraus, um sicherzustellen, dass er befe
-
stigt ist.
Crimpverbindungsmethode für Drähte ohne Anschlussleisten
Crimpverbindungsmethode für Anschlussdraht: Nach dem Anschluss muss der Draht mit der Kabelabdeckung befestigt werden.
Die Kabelabdeckung sollte auf die Schutzbeschichtung des Anschlussdrahts drücken, wie oben rechts abgebildet ist.
Hinweis: Achten Sie beim Anschluss der Drähte genau auf die Anschlussnummer der Innen- und Außengeräte. Bei unsachgemä
-
ßer Verdrahtung wird die Steuereinheit der Klimaanlage beschädigt oder das Gerät lässt sich nicht bedienen.
3. Verdrahtungsmethode beim Außengerät:
Netzleitung
Entfernen Sie die Reparaturplatine des Außengeräts und lösen die Kabelabdeckung A. Ziehen Sie dann den Nullleiter und den
Schutzleiter durch die Kabelabdeckung und schließen Sie diese auf entsprechende Weise an die Anschlussleiste an. Bringen Sie
die Kabelabdeckung nach dem Anschluss wieder so an, wie sie zuvor befestigt war. Kommunikationsdraht des Innengeräts.
Lösen Sie die Kabelabdeckung, stecken Sie den Kommunikationsdraht durch die Kabelabdeckung B und verbinden Sie ihn auf
entsprechende Weise mit der Anschlussleiste. Bringen Sie die Kabelabdeckung B nach dem Anschluss wieder so an, wie sie
zuvor befestigt war.
Hinweis: Netzleitung und Kommunikationsdraht müssen vom Kunden bereitgestellt werden.
Verbinden Sie den Draht
mit demselben Durchmes
-
ser mit den beiden Seiten
der Anschlussleiste
Verbinden Sie nicht
den Draht mit demsel
-
ben Durchmesser mit
derselben Seite
Verbinden Sie keine
Drähte mit unter
-
schiedlichen Durch
-
messern
Verdrahtungsmethod für
Ring-Anschlussleiste
Richtiger Druck
Falscher Druck
An-
schlusslei-
ste
Druckklam-
mern
Flüssigkeitsabsperrventil
Sechskant-
schlüssel
Schließen
Gasabsperrventil
Ventilkappe
13
–¨ 25.400
Verdrahtung
Kabelabdek-
kung A
Kabelabdek
-
kung C
Kabelabdek
-
kung B
Anschlussleiste
Ventilabdeckung
Kabelabdek
-
kung A
Kabelab-
deckung C
Kabelabdek
-
kung B
Kabelabdek
-
kung D
Ventilabdeckung
Anschlussleiste
Kabelab-
deckung E
4. Verdrahtungsmethode beim Innengerät
Lösen Sie die Kabelabdeckung und verbinden Sie die Netzleitung und den Kommunikationsdraht des Innengeräts auf entspre
-
chende Weise mit der Anschlussleiste.
Hinweis:
Beachten Sie bei der Verbindung der Netzleitung an die Stromversorgung die folgenden Punkte:
Verbinden Sie keine Netzleitung mit abweichenden Maßen an dasselbe Ende des Anschlussdrahts. Ein unsachgemäßer Kontakt
erzeugt Hitze.
Verbinden Sie keine Netzleitung mit abweichenden Maßen an dasselbe Ende des Schutzleiters. Ein unsachgemäßer Kontakt
beeinträchtigt die Schutzwirkung.
Verbinden Sie die Netzleitung nicht mit dem Anschlussende des Kommunikationsdrahts. Bei unsachgemäßem Anschluss wird
das angeschlossene Gerät beschädigt.
5. Beispiel eines Schaltplans.
Beziehen Sie sich für den Schaltplan bitte auf 5U34HS1 ERA
Verlegen Sie die Drähte so,
dass die Serviceklappe oder
andere strukturelle Teile
nicht angehoben werden.
Befestigen Sie die Abzweigverdrahtung fest mit
den
4 beigefügten Schrauben, wie abgebildet
ist. Achten Sie auf eine gute Befestigung, wobei
kein Druck von außen auf die Anschlussleisten
ausgeübt werden darf.
Verwenden Sie die
vorgegebenen Drähte
und schließen Sie sie
sachgemäß an.
14
Testlauf
Überzeugen Sie sich bitte vor dem Teststart, dass folgende Arbeiten erfolgreich ausgeführt wurden.
1) Richtige Rohrverlegung;
2) Richtige Verdrahtung;
3) Richtige Anpassung beim Innen- und Außengerät;
4) Sachgemäßes Nachfüllen des Kältemittels, sofern erforderlich.
Vergewissern Sie sich, dass alle Absperrventile ganz geöffnet sind.
Überzeugen Sie sich anhand einer Prüfung davon, dass die Innen- und Außengeräte mit einer Spannung von 230 Volt versorgt
werden.
Prüfung auf Verdrahtungsfehler
Dieses Produkt ist in der Lage, eine automatische Prüfung auf Verdrahtungsfehler vorzunehmen.
Schalten Sie alle 4 Dip-Switche auf der kleinen Service-Leiterplatte im Außengerät ein (ON), wie rechts
abgebildet ist. Schalten Sie das Gerät dann aus und wieder ein, woraufhin das System mit der "Prüfung auf
Verdrahtungsfehler" beginnt. Nach 3 Minuten im Standby-Betrieb beginnt das Gerät automatisch mit der
Verdrahtungsprüfung.
Etwa 30-50 Minuten (je nachdem, wieviele Geräte im System installiert sind) nach dem Gerätestart werden
die Verdrahtungsfehler anhand von LEDs (1 bis 5) aufgezeigt.
Während dieses Vorgangs werden abwechselnd die Betriebsfrequenz des Kompressors mittels Digitalziffer
(z. B. 50 steht für die aktuelle Betriebsfrequenz) und die Buchstaben "CH" (stehen für "Check" (Prüfung)) angezeigt.
Ist die gesamte Verdrahtung fehlerfrei wird nach diesem Vorgang die Digitalziffer "0" angezeigt; und ist etwas in der Verdrahtung
falsch, werden die Buchstaben "EC" ("Error connection" (Fehlerverbindung)) blinkend angezeigt.
Die Serviceüberwachungs-LEDs zeigen den Verdrahtungsfehler an, wie in folgender Tabelle dargestellt ist. Details zum Lesen der
LED-Anzeige sind im Servicehandbuch angegeben.
Ist eine Selbstprüfung des Geräts nicht möglich, prüfen Sie ganz normal die Verdrahtung und die Rohre des Innengeräts.
LED 1 2 3 4 5 Meldung
Status
AUS Gerät nicht angeschlossen
ALLE blinken
Automatische Prüfung nicht möglich,
alle Geräte falsch angeschlossen
ALLE EIN Alle Geräte sind richtig angeschlossen
EIN BLINKT BLINKT EIN BLINKT
EIN:Gerät richtig angeschlossen
BLINKT: Gerät falsch angeschlossen,
Verdrahtung muss zwischen 2, 3 und 5
manuell geändert werden
EIN BLINKT BLINKT EIN EIN
EIN: Gerät richtig angeschlossen
BLINKT: Gerät falsch angeschlossen,
Verdrahtung muss zwischen 2 und 3
manuell geändert werden
Nur eine LED blinkt
Unnormal
Testlauf.
1) Ist die Temperatur niedriger als 16°C, ist es nicht möglich den Kühlvorgang mit der Fernbedienung zu testen; auch wenn die
Temperatur höher ist als 30°C, kann der Heizvorgang nicht getestet werden.
2) Zum Testen des Kühlvorgangs setzen Sie die niedrigste Temperatur auf 16°C. Zum Testen des Heizvorgangs setzen Sie die
höchste Temperatur auf 30°C.
3) Prüfen Sie jeweils den Kühlvorgang und den Heizvorgang jedes einzelnen Geräts und prüfen Sie auch den Simultanbetrieb aller
Innengeräte.
4) Prüfen Sie nach einem Gerätebetrieb von etwa 20 Minuten die Auslasstemperatur des Innengeräts.
5) Wurde das Gerät angehalten oder die Betriebsart geändert, lässt sich das System ca. 3 Minuten lang nicht neu starten.
6) Während der Betriebsart Kühlen kann sich Frost auf dem Innengerät oder den Rohrleitungen bilden, was ganz normal ist.
7) Bedienen Sie das Gerät gemäß der Bedienungsanleitung. Erklären Sie unseren Kunden bitte die Bedienung mithilfe der Bedie
-
nungsanleitung.
Siebenstellige numerische Anzeige
1) Ist das Gerät in Betrieb, zeigt die siebenstellige numerische Anzeige die Frequenz des Kompressors an.
Zum Beispiel steht
"
" für eine Betriebsfrequenz des Kompressors von 40 Hz, " " steht für eine Betriebsfrequenz des Kom-
pressors von 108 Hz.
2) Wenn ein Betriebsfehler auftritt, blinkt die siebenstellige numerische Anzeige und zeigt einige Zahlen an,
die den Fehlercode darstellen. Wenn zum Beispiel "
" blinkt, liegt ein Fehler Nr. 32 vor, ein Kommunikati-
onsfehler beim Innen- und Außengerät.
Kommunikations-LED
5 grüne LEDs stehen für 5 Innengeräte. Leuchtet eine LED, steht das entsprechende Innengerät in guter Kommunikation mit dem
Außengerät. Leuchte eine LED nicht, gibt es keine Kommunikation zwischen dem Innen- und dem Außengerät.
15
Fehlerbehebung
Blinkszeit von
Zeitnahmeslampe
Blinkszeit von
Betriebslampe
Fehler der Außeneinheit EEPROM 1 15 2 1
IPM Überstrom oder Kurzschluss 2 16 2 2
Ausfall der Kommunikation zwischen Modul und ECU
Kommunikations-Kabel defekt oder nicht richtig angeschlossen
4 18 2 4
Überlastung der betriebenen Module 5 19 2 5
Modul mit niedrigen oder hohen Gleichspannung (unterhalb 192V oder
oberhalb 375V)
6 1A 2 6
Überhitzungsauslaßtemperatur. Zu wenig Kältemittel, zu hoch
Umgebungstemperatur oder PMVs blockiert
8 1C 2 8
Fehlfunktion des DC Lüftermotor 9 1D 2 9
Fehlfunktion vom entfrostenden Temparatursensor 10 1E 3 0
Fehlfunktion vom Temparatursensor an der Verdichtersaugseite 11 1F 3 1
Störung des Umgebungs-Temparatursensors 12 20 3 2
Störung des Verdichters-Temparatursensors 13 21 3 3
Kommunikationsfehler zwischen Innen- und Außengerät 15 23 3 5
Mangelnde Freon 16 36 3 6
Einschaltungsfehler vom 4- Wege-Ventil 17 25 3 7
Module-Überstrom / Module-Umschaltungsausfall 18 26 3 8
Innen Überlastung 20 28 4 0
Innen bereift 21 29 4 1
Module-Temperatur zu hoch ( überlastende Schutzeinrichtung) 23 2B 4 3
Überstrom vom Kompressor 24 2C 4 4
Eingangs-Überstrom 25 2D 4 5
MCU auf Null stellen 26 2E 4 6
Fehlfunktionen der Erkennungsschaltung fuer Modulestrom 27 2F 4 7
Störung des Temparatursensors der Flüssigkeitsleitung für Inneneinheit A 28 30 4 8
Störung des Temparatursensors der Flüssigkeitsleitung für Inneneinheit B 29 31 4 9
Störung des Temparatursensors der Flüssigkeitsleitung für Inneneinheit C 30 32 5 0
Störung des Temparatursensors der Flüssigkeitsleitung für Inneneinheit D 31 33 5 1
Störung des Temparatursensors der Gasleitung für Inneneinheit A 32 34 5 2
Störung des Temparatursensors der Gasleitung für Inneneinheit B 33 35 5 3
Störung des Temparatursensors der Gasleitung für Inneneinheit C 34 36 5 4
Störung des Temparatursensors der Gasleitung für Inneneinheit D 35 37 5 5
Störung des Temparatursensors der Gasleitung für Inneneinheit E 36 38 5 6
Störung des Moduls-Temparatursensors 38 3A 5 8
Störung vom kondensierenden Temparatursensor 39 3B 5 9
Fehlfunktion des flüssigen Leitungstemparatursensors für Inneneinheit E 40 3C 6 0
Fehlfunktionen von Rohrleitungs-Temparatursensor 41 3D 6 1
Systemsausschaltung bei hohem Druck 42 3E 6 2
Systemsausschaltung bei niedrigem Druck 43 3F 6 3
Systems- Hochdruck-Schutz. Kältemittels-Überfluss, hohe kondensierende
Temparatur oder Fehlfunktion des Lüftermotors
44 40 6 4
Systems-Niederdruck-Schutz. Kältemittelmangel, niedrige
Abtautemperatur, Oder eine Fehlfunktion des Lüftermotors
45 41 6 5
Störung des Moduls-Temparatursensors 46 42 6 6
Die fuer Fehlercode vom Kassette
und umsetzbar Innenbildschirm im
Freien verwendete Zeitnahme- und
Betriebslampe
kabelgebun
denen
Controller-
Bildschirm
Aussen
LED
Bildschirm
Mögliche Gründe
Adresse: No.1 Haier Road, Hi-tech Zone, Qingdao 266101, VR-China
Kontakt: TEL +86-532-8893-6943; FAX +86-532-8893-6999
Website: www.haier.com

Transcripción de documentos

MULTI-SPLIT AIR CONDITIONER INSTALLATION MANUAL Please read this manual carefully before installation. Keep this operation manual for future reference. No. 0150508607 D MULTI-SPLIT AIR CONDITIONER INSTALLATION MANUAL Contents Please read this manual carefully before installation. Keep this operation manual for future reference. 3 4 4 5 7 7 7 7 12 12 14 15 English Safety Precautions Accessories Precautions for Selecting the Location Installation drawings of indoor and outdoor units Precautions on Installation Outdoor Unit Installation Guideline Limitations on the installation Refrigerant piping work Pump Down Operation Wiring work Test running Trouble shooting Safety Precautions Read these Safety Precautions carefully to ensure correct installation. This manual classifies the precautions into WARNING and CAUTION. Be sure to follow all the precautions bellow: they are all important for ensuring safety. WARNING CAUTION Failure to follow any of WARING is likely to result in such grave consequences as death or serious injury. Failure to follow any of CAUTION may in some cases result in grave consequences. The following safety symbols are used throughout this manual: Be sure to observe this instruction Be sure to establish an earth connection Never attempt After completing installation, test the unit to check for installation errors. Give the user adequate instructions conceming the use and cleaning of the unit according to the Operation Manual. WARNING Installation should be left to the dealer or another professional. Improper installation may cause water leakage, electrical shock, or fire. Install the air conditioner according to the instructions given in this manual. Incomplete installation may cause water leakage, electrical shock, or fire. Be sure to use the suplied or specified installation parts. Use of other parts may cause the unit to cometo lose, water leakage, electrical shock, or fire. Install the air conditioner on a solid base that can support the unit's weight. An inadequate base or incomplete installation may cause injury in the event the unit falls off the base. Electrical work should be carried out in accordance with the installation manual and the national electrical wiring rules or code of practice. Insufficient capacity or incomplete electrical work may cause electrical shock or fire. Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance. For wiring, use a cable long enough to cover the entire distance with no connection. Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit. (Failure to do so may cause abnormal heat, electric shock or fire.) Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the interconnectiong wires so their terminals terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire. After connectiong interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels. Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire. If any refrigerant has leaked out during the installation work, ventilate the room. (The refrigerant produces a toxic gas if exposed to flames.) After all installation is complete, check to make sure that no refrigerant is leaking out. (The refrigerant produces a toxic gas if exposed to flames.) When installing or relocating the system, be sure to keep the refrigerant circuit free from substancs other than the specified refrigerant(R410A), such as air. (Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.) During pump-down, stop the compressor before removing the refrigerant piping. If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the rcompressor is run, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury. Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth. In complete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner. Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in electric shocks, or fire. CAUTION Do not install the aire conditioner in a place where there is danger of exposure to inflammable gas leakage. If the gas leaks and builds up around the unit, it may catch fire. Establish drain piping according to the instructions of this manual. Inadequate piping may cause flooding. Tighten the flare nut according to the specified method such as with a torque wrench. If the flare nut is tightened too hard, the falre nut may crack after a long time and cause refrigerant leakage. Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals. Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean. 3 Accessories Accessories supplied with the outdoor unit: Precautions for Selecting the Location 1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified. 2) Choose a location where the hot aire discharged from the unit or the operation noise, will not cause a nuisance to the neighbors of the user. 3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble. 4) There must be sufficient space for carrying the unit into and out of the site. 5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet. 6) The site must be free from the possibility of flammable gas leakage in a nearby place. Locate the unit so that the noise and the discharged hot air will not annoy the neighbors. 7) Install units, power cords and inter-unit cables at least 3 meter away from television and radio sets. This is to prevent interference to images and sounds. (Noises may be heard even if they are more than 3 meter away depending on radio wave conditions.) 8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner. 9)Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture. NOTE: Cannot be installed hanging from ceiling or stacked. CAUTION When operationg the air conditioner in a low outdoor ambient temperature, be sure to follow the instructions described below. 1) To prevent exposure to wind, install the outdoor unit with its suction side facing the wall. 2) Never install the outdoor unit at a site where the suction side may be exposed directly to wind. 3)To prevent exposure to wind, it is recommended to install a baffle plate on the air discharge side of the outdoor unit. 4) In heavy snowfall areas, select an installation site where the snow will not affect the unit. 4 Construct a large canopy. Construct a pedestal. Install the unit high enough off the ground to prevent burying in snow. Installation drawings of indoor and outdoor units Installation figure please refers to e or M an th More than 5cm 1. Do not connected the embedded branch piping and the outdoor unit when only carrying out piping work without connecting the indoor unit in ordor to add another indoor unit later. Make sure no dirt or mositure gets into eigher side of the embedded branch piping. 2.It is impossible to connect the indoor unit for one room only. cm 10 Arrangement of piping directions Rear left Rear right Left Right Below Attention must be paid to the rising up of drain hose Wrap the insulation pipe with the finishing tape from bottom to top. Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe's cut line. cm n 10 e tha mor mo re t han 10c m m 0c n6 a h t re mo mo re tha n2 5c m If there is the danger of the unit falling or overturning, fix the unit with foundation bolts, or with wire or other means. If the location does not have good drainage, place the unit on a level mounting base(or a plastic pedestal). Install the outdoor unit in a level position. Failure to do so may result in water leakage or accumulation. 5 Installation drawings of indoor and outdoor units Connection cautions model connection priority between indoor and stop valve higher from down to up when there is 1 indoor,the prior stop valve is C D E when there are 2 indoors,the prior stop valves are C B D C E D D C B E D C D C B A E D C B when there are 3 indoors,the prior stop valves are C B A when there are 4 indoors,the prior stop valves are when there are 5 indoors,the prior stop valves are E D C B A Note: For better oil return and more reliable system, please execute as the above when connecting indoor unit. 6 Precautions on Installation 20 Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installed. In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts.(Prepare four sets of M8 or M10 foundation bolts, nuts and washers each which are available on the market.) It is best to screw in the foundation bolts until their length are 20mm from the foundation surface. Outdoor Unit Installation Guideline Where a wall or other obstacle is in the path of outdoor unit's intake or exhaust airflow, follow the installation guidelines below. For any of the below installation pattems, the wall height on the exhaust side should be 1200mm or less. Wall facing one side More than 50 More than 300 1200 or less Side view Wall facing three sides Wall facing two sides More than 150 More More than 100 than 300 More than 50 More than 100 Side view More than 50 More than 300 Side view Limitations on the installation 1.Precautions on installation Check the strength and level of the installation ground so that unit will not cause any operating vibration or noise after installation. In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts. It is best to screw in the foundation bolts unit their length are 20 mm from the foundation surface. 2.Selecting a location for installation of the indoor units The maxinum allowable length of refrigerant piping, and the maxmum allowable height difference between the outdoor and indoor units, are listed below. (The shorter the refrigerant piping, the better the performance. Connect so that the piping is as short as possible. Shortest allowable length per room is 3m) 7 Limitations on the installation Indoor Unit Level difference: 15m max. Outdoor Unit Level difference: 15m max. Outdoor Unit Level difference: 7.5m max. Level difference: 7.5m max. Indoor Unit If the outdoor unit is positioned higher than the indoor units. (If lower than one or more indoor units.) If the outdoor unit is positioned higher than the indoor units. Refrigerant piping work 1. Installing outdoor unit 1) When installing the outdoor unit, refer to "Precautions for Selecting the Location" and the "Indoor/Outdoor Unit Installation Drawings". 2)If drain work is necessary, follow the procedures below. 2. Drain work 1) Use drain plug for drainage. 2) If the drain port is covered by a mounting base or floor surface, place additional foot bases of at least 30mm in height under the outdoor unit's feet. 3) In cold areas, do not use a drain hose with the outdoor unit.(Otherwise, drain water may freeze, impairing heating performance.) Hose Hose Drain elbow 8 Drain elbow Refrigerant piping work 3. Refrigerant piping work 1). Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the tor wrenches. Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and escaping gas. Flare nut fightening torque Flare nut for 6.35 14.2-17.2N.m(144-175kgf.cm) Flare nut for 9.52 32.7-39.9N.m(333-407kgf.cm) Flare nut for 12.7 49.5-60.3N.m(505-615kgf.cm) Flare nut for 15.88 61.8-75.4N.m(630-769kgf.cm) Valve cap tightening torque Liquid pipe 26.5-32.3N.m(270-330kgf.cm) Coat here with refrigeration oil Torque spanner Spanner Service port cap tightening torque Pipe joint 10.8-14.7N.m(110-150kgf.cm) Gas pipe 48.1-59.7N.m(490-610kgf.cm) Cone nut 2)To prevent gas leakage, apply refrigeration oil on both inner and outer surfaces of the flare. (Use refrigeration oil for R410A) 4. Purging air and checking gas leakage When piping work is completed, it is necessary to purge the air and check for gas leakage. WARNING 1) Do not mix any substance other than the specified refrigerant (R410A) into the refrigeration cycle. 2) When refrigerant gas leaks occur, ventilate the room as soon and as much as possible. 3) R410A, as well as other refrigerants, should always be recovered and never be released directly into the environment. 4) Use a vacuum pump for R410A exclusively. Using the same vacuum pump for different refrigerents may damage the vacuun pump or the unit. If using additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then charge additional refrigerant. Use a hexagonal wrench (4mm) to operate the stop valve rod. All refrigerant pipe joints should be tightened with a torque wrench at the specified tightening torque. Connect projection side of charging hose(Which comes from gauge manifold) to gas stop valve's service port. Fully open gauge manifold's low-pressure valve(Lo) and completely close its high-pressure valve(Hi). (High-pressure valve subsequently requires no operation.) Apply vacuum pumping. Check that the compound pressure gauge reads-0.1MPa(-76cmHg). Evacuation for at lease 1 hour is recommended. Close gauge manifold's low-pressure valve(Lo) and stop vacuum pump. (Leave as is for 4-5 minutes and make sure the coupling meter needie does not go back. If it does go back, this may indicate the presence of moisture or leaking from connecting parts. After inspecting all the connection and loosening then retightening thenuts, reqeat steps 2-4. ) Remove covers from liquid stop valve and gas stop valve. Turn the liquid stop valve's rod 90 degrees counterclockwise with a hexagonal wrench to open valve. Close it after 5 seconds, and check for gas leakage. Using soapy water, check for gas leakage from indoor unit's flare and outdoor unit's flare and valve rods. After the check is complete, wipe all soapy water off. Disconnect charging hose from gas stop valve's service port, then fully open liquid and gas stop valves. (Do not attempt to turn valve rodj beyond its stop.) Tighten valve caps and service port caps for the liquid and gas stop valves with a torque wrench at the specified torques. See "3 Refrigerant piping " on page 6 for details. 9 Refrigerant piping work 5. Refilling the refrigerant Check the type of refrigerant to be used on the machine namiplate. Precautions when adding R410A Fill from the liquid pipe in liquid form. It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, preventing normal operation. 1) Before filling, check whether the cylinder has a siphon attached or not.(It should have something like "liquid filling siphon attached" displayed on it.) Filling a cylinder with an attached siphon Filling other cylinders Stand the cylinder upright when filling. Turn the cylinder upside-down when filing. There is a siphon pipe inside, so the cylinder need not be upside-down to fill with liquid. 2) Be sure to use the R410A tools to ensure pressure and to prevent foreign objects entering. 6. Charging with refrigerant 1) This system must use refrigersant R410A. 2) Add refrigerant 20g per meter when the total piping length exceeds the standard value, but make sure that the total liquid piping length should be less than the max. value. Notes: 1) When using this product, you need not to set the address. But the L/N wires between indoor & outdoor units must be corresponded, or there will be communication failure. 2) Quiet Operation Setting. Set the DIP "8" to ON position of SW5, the system will run with lower noise, but the max. capacity will also reduce slightly. 3) Do not change the settings of other switchs, wrong settings can make the system damage or other malfunctions. 7.Precautions for Laying Refrigerant Piping Cautions on pipe handling 1) Protect the open end of the pipe against dust and moisture. 2) All pipe bends should be as gentle as possible. Use a pipe bender for bending.(Bending radius should be 30 to 40mm or larger.) Selection of copper and heat insulation materials When using commercial copper pipes and fittings, observe the following : 1) Insulation material: Polyethylene foam o Heat transfer rate: 0.041 to 0.052W/mK(0.035to 0.045kcal/mh C) o Refrigerant gas pipe's surface temperature reaches 110 C max. Choose heat insulation materials that will withstand this temperature. 2) Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below. 10 Gas pipe Gas pipe insulation O.D.:9.52mm,12.7mm Thickness:0.8mm I.D.:12-15mm,12.7mm Thickness:13mm min. Liquid pipe Liquid pipe insulation O.D.:6.35mm Thickness:0.8mm I.D.:18-10mm Thickness:10mm min. Refrigerant Piping Work 3) Use separate thermal insulation pipes for gas and liquid refrigerant pipe. Inter unit wiring Gas pipe Wall Be sure to place a cap. Liquid pipe Rain If no flare cap is available, cover the flare mouth with tape to keep dirt or water out. Liquid pipe insulation Gas pipe insulation Finishing tape Drain hose Check Flare's inner surface must be flaw-free. The pipe end must be evenly flared in a perfect circle. Cut exactly at right angles. Remove burrs Make sure that the flare nut is fitted. Set exactly at the position shown below. A Flare tool for R410A Flare tooling die Conventional flare tool Clutch-type Clutch-type(Rigid-type) Wing-nuttype(Imperial-type) 0-0.5mm 1.0-1.5mm 1.5-2.0mm 8.Cutting and Flaring work of piping Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out. A Flare tooling die Pipe Pipe diameter Liquid side Gas side Size A (mm) 6.35mm(1/4") 0.8~1.5 9.52mm(3/8") 1.0~1.5 12.7mm(1/2") 1.0~1.5 Correct Incorrect Lean Damage of flare Crack Partial 9. On drainage Please install the drain hose so as to be downward slope without fail. Please don't do the drainage as shown below. Less than 5cm It becomes high midway. The end is immersed in water It gap with the ground its too small. It waves. There is the bad smell from a ditch. Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out serely to outdoor. In case that the attached drain hose is in a room, please apply heat insulation to it without fail. WARNING 1) Do not use mineral oil on flared part. 2) Prevent mineral oil from getting into the system as this would educe the lifetime of the units. 3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit. 4) Do never install a drier to this R410A unit in order to guarantee its lifetime. 5) The drying material may dissolve and damage the system. 6) Incom;ete flaring may cause refrigerant gas leakage. 11 Too outside Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve caps from liquid stop valve and gas stop valve. 2) Carry out forced cooling operation. 3) After five to ten minutes, close the liquid stop valve with a hexagonal wrench. 4) After two to three minutes, close the gas stop vaile and stop forced cooling operation. liquid stop valve Hexagonal wernch Close Gas stop valve Valve cap Wiring work 1. Electric wiring The air conditioner must use special circuit , and wiring by the qualified electrician according to the wiring rules specified in national standard. The grounding wire and the neutral wire shall be strictly separated. Connect the neutral wire with grounding wire is incorrect. The electric leakage breaker must be installed. All the electric wire must be copper wire.Power supply: The wiring method of power line is Y connection. If the power line is damaged, in order to avoid risk of electric shock, it must be replaced by the manufacturer or its repair center or other similar qualified person.The connecting cable must be shielded. Fuse: T3.15A 250VAC T16A 250VAC (Please check with the outdoor unit wiring diagram.) Please check the circuit diagram about the fuse replaced. 2. Wiring method Wiring method of orbicular terminals For the connection wire with orbicular terminals, its wiring method is as shown in the right figure: remove the connecting screw, put the screw through the ring on the end of the wire, then connect to the terminal block and fasten screw. Wiring method of straight terminals. For the connection wire without orbicular terminals, its wiring method is: loosen the connection screw, and insert the end of the connection wire completely into the Terminal block, then fasten the screw. Slightly pull the wire outwards to confirm it is firmly held. Wiring Method for Ring Terminal Block Crimp connection method for wires without terminals Connect the wire with same diameter to the two sides of the terminal Do not connect the wire with same diameter to the same side Wrong Pressing Correct Pressing Do not connect the wire with different diameters Terminal block Pressing Clamps Crimp connection method for connection wire After connection,the wire must be fastened by wire cover. The wire cover shall press on the protection coat of the connection wire,as shown in right top figure. Note:When connecting the wiring,confirm the terminal number of indoor and outdoor units carefully. Incorrect wiring will damage the controller of air conditioner or the unit can not operate. 3. Wiring method of outdoor unit: Power line Remove the repair board of the outdoor unit and loosen the wire cover A,then put the live wire, neutral wire and grounding wire through the wire cover ,and connect them to terminal block correspon dingly. After connection, fasten wire cover to its previous state. Communication wire of indoor unit. Loosen wire cover , put the communication wire through the wire cover B, and connect them to terminal block correspondingly. After connection, fasten wire cover B to its previous state. Note: Power line and communication wire are provided by consumers themselves. 12 Wiring work Wire cover A Wire cover A Wire cover C Terminal block Wire cover C Wire cover B Wire cover B Terminal block Valve cover –¨ 25.40 Wire cover D Wire cover E Valve cover 0 4. Wiring method of indoor unit Loosen wire cover and connect the power line and communication wire of indoor unit to the terminal correspondingly. Note: When connecting power line to power supply terminal, please pay attention to the following items: Do not connect the power line with different dimensions to the same connection wire end. Improper contact will cause heat generation. Do not connect the power line with different dimensions to the same grounding wire end. Improper contact will affect protection. Do not connect the power line to the connecting end of communication wire. Incorrect connection will cause damage to the connected unit. 5. Example wiring diagram. Wiring diagram please refers to 13 Test running Before starting the test running, please confirm the following works have been done successfully. 1) Correct piping work; 2) Correct wiring work; 3) Correct match of indoor and outdoor unit; 4) Proper recharge of refrigerant if needed. Make sure that all the stop valves are fully open. Check the voltage supplied to the outdoor and indoor units, please cinfirm that is 230V. Wiring Error Check This product is capable of automatic checking of wiring error. CN2 Switch on all the 4 dip-switches on the outdoor unit small service PC-board as shown on the right. Then power off the unit and power on again, the system will enter the operation of "Wiring Error Check". After 3 minutes stand-by, the unit starts for automatic wiring checking. Approximately 30 ~ 50minutes (depends on how many units installed in the system) after the unit starts, the Errors of the wiring will be shown by the LEDs (1 to 5). CN3 SW1 ON CN4 1234 CN1 1 2 3 4 5 During this operation, the digital-number will alternately show the compressor working frequency (e.g. 50 stands for the current running frequency) and letter "CH"(means checking). After this operation, if all the wiring is correct, the digital-number will show "0", if there has wrong wiring, the digital-number will show "EC"(error connection) and also it will flashing. The service monitor LEDs indicate the error of wiring, as shown in the table below. For details about how to read the LED display, refer to the service manual. If self-checking is not possible, check the indoor unit wiring and piping in the usual manner. Status Only one LED flashing Test running. 1) If the temperature is lower than 16 OC, it is impossible to test cooling with remote controller, and also when the temperature is higher than 30 OC, it is impossible to test heating. 2) To test cooling, set the lowest temperature at 16 OC. To test heating,set the highest temperature, at 30 OC. 3) Please check both cooling and heating operation of each unit individually and then also check the simultaneous operation of all indoor units. 4) After ruuning the unit for about 20 minutes, check the indoor unit outlet temperature. 5) After the unit is stopped, or working mode changed, the system will not start again for about 3 minutes. 6) During cooling operation, frost may ocur on the indoor unit or pipes, this is normal. 7) Operate the unit according to the operation manual. Please kindly explain to our customers how to operate through the instruction manual. Seven-segment numeric display 1) When unit is runing, this seven-segment numeric will display the frequency of compressor. For example," " means compressor running frequency is 40 Hz, " " means compressor running frequency is 108Hz. 2) When faulty happens, seven-segment numeric will flash and display some numbers, this number is failure code. For example, a flashing " " means No.32 failure, that is indoor and outdoor communication error. CN2 CN3 SW1 ON CN4 1234 CN1 1 2 3 4 5 Communication LED 5 green LED means 5 indoor units. If one LED keep lighting that means the corresponding indoor unit has good communication with outdoor unit. If one LED is not lighting, that means there is no communication between indoor and outdoor. 14 Trouble shooting Cassette and convertible Outdoor LED Wired display controller indoor display outdoor error display code use the timer and runing lamp Possible reasons Faulty of outdoor unit EEPROM IPM overcurrent or short circuit Communication failure between Module and ECU Communication cables broken or not well connected. Module operated overload Module low or high DC voltage(under 192V or above 375V) Discharging temperature overheating.Lack of refrigerant, ambient temperature too high or PMVs blocked. Malfunction of the DC fan motor Malfunction of defrosting temp. sensor Malfunction of compressor suction temp. sensor Malfunction of ambient temp. sensor Malfunction of compressor discharge temp. sensor Communication failure between indoor&outdoor unit Lack of refrigerant or discharging pipe blocked 4-way valve switching failure Module overcurrent /Module switch failure Indoor overload Indoor frosted Module temperature too high (Overload Protecter) Compressor overcurrent Input overcurrent MCU reset Module current detect circuit malfunction Malfunction of liquid pipe temp. sensor for indoor unit A Malfunction of liquid pipe temp. sensor for indoor unit B Malfunction of liquid pipe temp. sensor for indoor unit C Malfunction of liquid pipe temp. sensor for indoor unit D Malfunction of gas pipe temp. sensor for indoor unit A Malfunction of gas pipe temp. sensor for indoor unit B Malfunction of gas pipe temp. sensor for indoor unit C Malfunction of gas pipe temp. sensor for indoor unit D Malfunction of gas pipe temp. sensor for indoor unit E Malfunction of module temp.sensor Malfunction of condensing temp. sensor Malfunction of liquid pipe temp. sensor for indoor unit E Malfunction of piping temp. sensor System high pressure switch off System low pressure switch off System high pressure protection.Refrigerant overabundance,High condensing temp. or malfunction of fan motor. System low pressure protection.Refrigerant shortage, Low defrosting temp., or malfunction of fan motor. Malfunction of module temp.sensor 1 2 4 15 16 18 Timer lamp flash time 2 2 2 5 6 19 1A 2 2 5 6 8 1C 2 8 9 10 11 12 13 15 16 17 18 20 21 23 24 25 26 27 28 29 30 31 32 33 34 35 36 38 39 40 41 42 43 44 1D 1E 1F 20 21 23 36 25 26 28 29 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 3A 3B 3C 3D 3E 3F 40 2 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 6 6 6 6 6 9 0 1 2 3 5 6 7 8 0 1 3 4 5 6 7 8 9 0 1 2 3 4 5 6 8 9 0 1 2 3 4 45 41 6 5 46 42 6 6 15 Running lamp flash time 1 2 4 MANUAL DE INSTALACIÓN DEL APARATO DE AIRE ACONDICIONADO DE TIPO MULTISPLIT Precauciones de seguridad ---------------- 3 Accesorios ------------------------------------ 4 Precauciones para seleccionar la ubicación ---------------------------------------4 Esquemas de instalación de las unidades interior y exterior ------------------------------ 5 Precauciones a la hora de realizar instalación -------------------------------------7 Guía de instalación de la unidad exterior -----------------------------------------7 Limitaciones en la instalación ------------- 7 - de los tubos de Acometida refrigerante ------------------------------------7 Funcionamiento de la bomba de vacío -------------------------------------------12 Cableado --------------------------------------12 - del aparato --------------------------14 Prueba - de problemas -----------------15 Resolución -  Lea detenidamente este manual antes de instalar el aparato. Guarde este manual de uso para futuras consultas. Español Contenido Haier Industrial Park, No.1 Haier Road, Qingdao, República Popular China CONFORMIDAD DE LOS MODELOS SEGÚN LAS NORMATIVAS EUROPEAS INFORMACIÓN IMPORTANTE ACERCA DEL REFRIGERANTE UTILIZADO CE Todos los productos cumplen los requisitos de las siguientes normas europeas: - Directiva de baja tensión 73/23/CEE - Directiva de baja tensión 2006/95/CE - Compatibilidad electromagnética 89/336/CEE - Compatibilidad electromagnética 2004/108/CE ROHS Los productos cumplen los requisitos de la directiva 2002/95/ CEE establecida por el Parlamento Europeo y el Consejo sobre la Restricción del uso de determinadas sustancias peligrosas en aparatos eléctricos y electrónicos (Directiva RoHS de la Unión Europea). WEEE De acuerdo con la directiva 2002/96/CE del Parlamento Europeo, se informa al consumidor acerca de los requisitos que han de cumplirse para deshacerse de productos eléctricos y electrónicos. REQUISITOS DE DESECHO: Su aparato de aire acondicionado ha sido marcado con este símbolo que significa que los productos de tipo eléctrico y electrónico no deben mezclarse con la basura doméstica sin clasificar. No intente desmontar el sistema por sí mismo: tanto el desmontaje del sistema de aire acondicionado como la manipulación del refrigerante, el aceite y cualquier otro componente deben ser llevados a cabo por un instalador cualificado, de acuerdo con la legislación local y nacional aplicable. Los aparatos de aire acondicionado deben ser tratados en instalaciones de manipulación especializadas para su reutilización, reciclado y recuperación. Al garantizar la correcta eliminación de este producto, estará contribuyendo a evitar las posibles consecuencias negativas que podría provocar sobre el medioambiente y la salud humana. Póngase en contacto con el instalador o la autoridad local pertinente si desea obtener más información. Las pilas deben ser extraídas del mando a distancia y eliminadas de forma independiente, de acuerdo con la legislación local y nacional aplicable. Contiene gases fluorados de efecto invernadero regulados por el Protocolo de Kioto. Kg Kg Kg Este producto contiene gases fluorados de efecto invernadero regulados por el Protocolo de Kioto. No los libere a la atmósfera. Tipo de refrigerante: R410A Valor GWP*: 1975 1975 GWP = Potencial de contribución al calentamiento global Escriba con tinta indeleble: •1 La carga de refrigerante que contiene el producto de fábrica •2 La cantidad de refrigerante adicional cargada in situ y • 1+2 La carga total de refrigerante en la etiqueta de refrigerante suministrada con el producto. Una vez escritos los datos correspondientes, la etiqueta deberá adherirse cerca de la conexión de carga del producto (por ejemplo, sobre la parte interna de la cubierta de la válvula de retención). A Contiene gases fluorados de efecto invernadero regulados por el Protocolo de Kioto. B Carga de refrigerante que contiene el producto de fábrica: consulte la placa de características de la unidad. C Cantidad de refrigerante adicional cargada in situ. D Carga total de refrigerante. E Unidad exterior. F Botella de refrigerante y analizador para carga. Precauciones de seguridad • Lea estas precauciones de seguridad atentamente para garantizar la correcta instalación del aparato. • Este manual clasifica las precauciones en los tipos ADVERTENCIA y PRECAUCIÓN. • Asegúrese de tener en cuenta estas instrucciones. ya que son importantes para garantizar la seguridad. ADVERTENCIA Si no se sigue alguna de las ADVERTENCIAS es probable que se produzcan consecuencias graves, como lesiones personales o, incluso, la muerte. PRECAUCIÓN El hecho de no seguir alguna de las PRECAUCIONES puede dar lugar a consecuencias graves. • En este manual se utilizan los siguientes símbolos de seguridad: Asegúrese de tener en cuenta estas instrucciones. Asegúrese de establecer una conexión de toma de tierra. No intentar nunca. • Después de completar la instalación, pruebe la unidad para comprobar si hay errores en dicha instalación. Proporcione al usuario las instrucciones adecuadas relativas al uso y la limpieza de la unidad conforme al manual de funcionamiento. ADVERTENCIA • La instalación debe ser realizada por el distribuidor u otro profesional. Una instalación incorrecta podría provocar fugas de agua, descargas eléctricas o un incendio. • Instale el aparato de aire acondicionado conforme a las instrucciones proporcionadas en este manual. Una instalación incompleta podría provocar fugas de agua, descargas eléctricas o un incendio. • Asegúrese de utilizar los componentes de instalación suministrados o especificados. El uso de otros componentes puede hacer que la unidad quede suelta, que haya fugas de agua, descargas eléctricas o que se produzca un incendio. • Instale el aparato de aire condicionado en una base sólida que soporte el peso de la unidad. Una base inadecuada o una instalación incompleta puede provocar lesiones si la unidad se desprende de la base. • Las conexiones eléctricas deben ser llevadas a cabo conforme al manual de instalación y cumpliendo las normas de cableado eléctrico nacionales y el código de práctica. Una capacidad insuficiente o unas conexiones eléctricas incompletas pueden provocar descargas eléctricas o un incendio. • Asegúrese de utilizar un circuito de alimentación dedicado. No utilice nunca una fuente de alimentación compartida por otro aparato. • Para el cableado, utilice un cable lo suficientemente largo como para cubrir toda la distancia sin empalmes. No utilice un alargador. No coloque otras cargas en la fuente de alimentación y utilice un circuito de alimentación dedicado. (Si no sigue estas indicaciones, el funcionamiento en modo de calefacción puede ser anómalo o se pueden producir descargas eléctricas o un incendio.) • Utilice los tipos especificados de cables para las conexiones eléctricas entre las unidades interior y exterior. Sujete firmemente con abrazaderas los cables de interconexión de forma que sus terminales no sufran tirones producidos por fuerzas externas. Las conexiones o sujeción con abrazaderas incompletas pueden provocar sobrecalentamiento en los terminales o un incendio. • Después de conectar todos los cables asegúrese de darles la forma adecuada para que no estén sometidos a una fuerza excesiva en las tapas o paneles eléctricos. Instale las tapas sobre los cables. Una instalación incompleta podría provocar sobrecalentamiento en los terminales, descargas eléctricas o un incendio. • Si ha habido fugas de refrigerante durante la instalación, ventile la habitación. (El refrigerante produce un gas tóxico si se expone a las llamas.) • Una vez realizada la instalación, asegúrese de que no hay fugas de refrigerante. (El refrigerante produce un gas tóxico si se expone a las llamas.) • Cuando se instale o cambie de ubicación el sistema, asegúrese de que no hay sustancias distintas al refrigerante especificado (R410A) en el circuito refrigerante, como por ejemplo aire. (Cualquier presencia de aire u otra sustancia extraña en el circuito refrigerante, provocará una elevación de la presión anormal o rupturas, lo que provocará lesiones personales.) • Durante el vaciado, detenga el compresor antes de quitar los tubos de refrigerante. Si el compresor sigue en funcionamiento y la válvula de retención se abre durante el vaciado, el aire se succionará cuando el compresor esté en funcionamiento, lo que provocará una presión anormal en el circuito refrigerador que dará lugar a fugas e, incluso, a lesiones personales. • Asegúrese de establecer una conexión de toma de tierra. No utilice tubos, cables, ni la toma de tierra del teléfono para conectar a tierra la unidad. Una conexión a tierra incompleta puede provocar descargas eléctricas o un incendio. Una fuerte subida de corriente causada por rayos u otras fuentes, puede provocar daños en el aparato de aire acondicionado. • Asegúrese de instalar un interruptor de fugas a tierra. Si no instala un interruptor de fugas a tierra se pueden producir descargas eléctricas o un incendio. PRECAUCIÓN • No instale el aparato de aire acondicionado en un lugar en el que haya peligro de exposición a fugas de gas inflamable. Si el gas se fuga y se acumula alrededor de la unidad, se puede producir un incendio. • Establezca los tubos de desagüe conforme a las instrucciones este manual. Una canalización inadecuada puede provocar inundaciones. • Apriete la tuerca abocardada conforme al método especificado utilizando una llave dinamométrica. Si la tuerca abocardada se aprieta demasiado, podría agrietarse lo que daría lugar a fugas de refrigerante después de un largo período de uso. • Asegúrese de proporcionar las medidas adecuadas para evitar que la unidad exterior se utilice como refugio para animales pequeños. Los animales pequeños pueden entrar en contacto con componentes eléctricos y causar averías, humo o un incendio. Indique al cliente que mantenga limpia el área alrededor de la unidad.  Accesorios Accesorios suministrados con la unidad exterior: Nº Dibujo Nombre de los componentes Cantidad Nota 1 1 Codo de desagüe 2 Protección de goma 3 Abrazadera 3 4 1 3 4 Adaptador (3/8 1/2) 1 5 Adaptador (1/2 3/8) 1 Precauciones para seleccionar la ubicación 1) Elija un lugar lo suficientemente resistente como para soportar el peso y las vibraciones de la unidad y donde el ruido de funcionamiento no se amplifique. 2) Elija una ubicación en la que el aire caliente emitido por la unidad o el ruido de funcionamiento no causen molestias a los vecinos del usuario. 3) Evite los lugares cercanos a dormitorios y dependencias similares para que el ruido de funcionamiento no ocasione problemas. 4) Debe haber un espacio suficiente en el lugar de la instalación para meter y sacar la unidad. 5) Debe haber un espacio suficiente en el lugar de la instalación para que fluya el aire y no debe haber obstáculos alrededor de la entrada y salida de aire. 6) En las proximidades del lugar de la instalación no debe existir la posibilidad de fugas de gas inflamable. Coloque la unidad de forma que el ruido y el aire caliente emitido no molesten a los vecinos. 7) Instale las unidades, los cables de alimentación y los cables que conectan las unidades a una distancia de al menos 3 metros de equipos de televisión y radio. De esta forma se evitarán interferencias en la imagen y el sonido. (En función de las condiciones de las ondas de radio, los ruidos pueden oírse incluso si hay más de tres metros de distancia.) 8) En áreas costeras u otros lugares con atmósfera salada o gas sulfato, la corrosión puede acortar el período de vida útil del aparato de aire acondicionado. 9) Dado que el sistema de desagüe sale de la unidad exterior, no coloque nada que no resista la humedad debajo de dicha unidad. NOTA: No se puede instalar colgándose del techo ni apilándolo. PRECAUCIÓN  Cuando utilice el aparato de aire acondicionado a una temperatura ambiente exterior baja, asegúrese de seguir las instrucciones descritas a continuación. 1) Para evitar la exposición al viento, instale la unidad exterior con su lado de succión orientado hacia la pared. 2) Nunca instale la unidad exterior en una ubicación en la que el lado de succión pueda estar expuesto directamente al viento. 3) Para evitar la exposición al viento, es recomendable instalar un deflector en el lado de descarga del aire de la unidad exterior. 4) En áreas donde nieve mucho, seleccione un lugar de instalación en el que la nieve no afecte a la unidad. • • Construya una cubierta grande. Construya un pedestal. Instale la unidad a una altura suficiente del suelo como para evitar que quede cubierta por la nieve. Esquemas de instalación de las unidades interior y exterior Consulte para ver la figura de instalación M ás de 10 Más de 5 cm 1. Cuando realice trabajos de conexión de tubos no conecte la derivación de tubo integrada ni la unidad exterior sin conectar antes la unidad interior para poder añadir más tarde otra unidad interior. Asegúrese de que no entra suciedad o humedad por ambos lados de la derivación integrada del tubo. 2. Es imposible conectar la unidad interior solamente para una habitación. cm Organización de la dirección de los tubos Izquierda trasera Izquierda Derecha trasera Derecha Debajo Debe prestarse atención a la pendiente del manguito de desagüe Envuelva el tubo el aislamiento con la cinta de Corte el tubo de aislamiento térmico por la longitud adecuada y envuélvalo con cinta asegurándose de que no quedan huecos en la línea de corte del tubo de aislamiento. m e 10 c Más d Má s de 10 c m m 5c e2 sd Má m 0c e6 d s Má  Si hay peligro de que la unidad se caiga, fíjela con pernos para suelo, con un cable o con otros medios. Si la ubicación no dispone de un buen sistema de drenaje, coloque la unidad en una base de montaje nivelada (o en un pedestal de plástico). Instale la unidad exterior en una posición nivelada. Si no sigue estas indicaciones, se pueden producir fugas o acumulación de agua. Esquemas de instalación de las unidades interior y exterior Precauciones para la conexión modelo prioridad de conexión entre la unidad interior y la válvula de retención más alta de abajo a arriba C D E cuando hay una unidad interior, la válvula de retención previa es cuando hay 2 unidades CB DC ED interiores, las válvulas de retención previas son cuando hay 3 unidades CBA DCB EDC interiores, las válvulas de retención previas son cuando hay 4 unidades DCBA EDCB interiores, las válvulas de retención previas son cuando hay 5 unidades EDCBA interiores, las válvulas de retención previas son Nota: para mejorar el retorno del aceite y la fiabilidad del sistema, siga las indicaciones anteriores cuando conecte la unidad interior.  Precauciones a la hora de realizar instalación • Compruebe la resistencia y el nivel de la superficie de la instalación para que la unidad no cause vibraciones o ruido durante su funcionamiento después de instalada. • En función de los planos de los cimientos, fije la unidad de forma segura mediante los pernos para suelo. (Prepare cuatro juegos de pernos para suelo M8 o M10, tuercas y arandelas. Todos estos componentes están disponibles en el mercado.) • Atornille los pernos para suelo hasta que se hayan introducido 20 mm. Guía de instalación de la unidad exterior • Siga las instrucciones de instalación que se indican a continuación cuando haya una pared u otros obstáculos en la trayectoria del flujo de aire de entrada o salida de la unidad exterior. • Para cualquiera de los modelos de instalación siguientes, la altura de la pared del lado de la salida de aire debe ser de 1200 mm como máximo. Pared en un lado Más de 300 mm Más de 50 mm 1200 mm como máximo Vista lateral Pared en dos lados Pared en dos lados Más de 100 mm Más de 150 mm Más de 300 mm Más de 50 mm Más de 100 mm Vista lateral Más de 50 mm Más de 300 mm Vista lateral Limitaciones en la instalación 1.Precauciones a la hora de realizar la instalación • Compruebe la resistencia y el nivel de la superficie de la instalación para que la unidad no cause vibraciones o ruido durante su funcionamiento después de instalada. • En función de los planos de los cimientos, fije la unidad de forma segura mediante los pernos para suelo. • Atornille los pernos para suelo hasta que se hayan introducido 20 mm. 2.Seleccionar una ubicación para la instalación de las unidades interiores • A continuación se muestran la longitud máxima permitida de los tubos de refrigerante y la diferencia de altura máxima permitida entre la unidad exterior y las unidades interiores. Cuanto más cortos sean los tubos de refrigerante, mayor será el rendimiento. Por tanto, realice las conexiones de forma que los tubos sean tan cortos como sea posible. La longitud más corta permitida por habitación es de 3 m. Clase de capacidad de la unidad exterior máximo. máximo. máximo. máximo. máximo. máximo. máximo. máximo.  Tubos a cada unidad interior Longitud total de los tubos entre todas las unidades Limitaciones en la instalación Unidad interior Unidad exterior Diferencia de nivel: 15m máximo. Diferencia de nivel: 15m máximo. Diferencia de nivel: 7,5 m máximo. Diferencia de nivel: 7,5 m máximo. Unidad exterior Unidad interior Si la unidad exterior no se coloca en una posición más elevada que las unidades interiores. (Si se ubica en una posición más baja que una o varias unidades interiores.) Si la unidad exterior no se coloca en una posición más elevada que las unidades interiores. Unidad interior Diferencia de nivel: 15m máximo. Diferencia de nivel: 7,5 m máximo. Unidad exterior Si la unidad interior se coloca en una posición más elevada que las unidades exteriores. Acometida de los tubos de refrigerante 1.Instalar la unidad exterior 1) Cuando instale la unidad exterior, consulte las secciones "Precauciones para seleccionar la ubicación" y "Esquemas de instalación de las unidades interior y exterior". 2) Si es necesario realizar un desagüe, siga los procedimientos que se indican a continuación. 2.Desagüe 1) Utilice un tapón de desagüe para el drenaje. 2) Si el puerto de desagüe está tapado por la base de montaje o por la superficie del suelo, coloque unos pies adicionales que tengan una altura de al menos 30 mm debajo de los pies de la unidad exterior. 3) En zonas frías, no utilice una manguera de desagüe con la unidad exterior ya que, de lo contrario, el agua del desagüe se puede congelar, lo que afectará negativamente al rendimiento en el modo de calefacción. Manguera Manguera Codo de desagüe  Codo de desagüe Acometida de los tubos de refrigerante 3. Acometida de los tubos de refrigerante 1) Alinee los centros de ambas tuercas abocardadas y apriételas girándolas tres o cuatro vueltas con la mano. A continuación, apriételas completamente con las llaves dinamométricas. Utilice llaves dinamométricas cuando apriete las tuercas abocardadas para evitar daños en las mismas y fugas de gas. Par de apriete de las tuercas abocardadas Tuerca abocardada para 6,35 14,2-17,2 N.m (144-175 kgf.cm) Tuerca abocardada para 9,52 32,7-39,9 N.m (333^07 kgf.cm) Tuerca abocardada para 12,7 49,5-60,3 N.m (505-615 kgf.cm) Tuerca abocardada para 15,88 61,8-75,4 N.m (630-769 kgf.cm) Par de apriete de la tapa de la válvula Tubo de líquido 26,5-32,3 N.m (270-330 kgf.cm) Tubo de líquido 48,1-59,7N.m (490-610 kgf.cm) Recubrir esta zona con aceite refrigerante Llave de par torsiométrica Llave fija Unión del tubo Par de apriete de la tapa del puerto de servicio Tuerca abocardada 10,8-14,7 N.m (110-150 kgf.cm) 2) Para evitar fugas de gas, aplique aceite refrigerante tanto a la superficie interior como exterior de la tuerca abocardada. Utilice aceite refrigerante para R410A. 4. Purgar el aire y comprobar si hay fugas de gas Cuando haya finalizado de realizar la acometida de los tubos es necesario purgar el aire y comprobar si hay fugas de gas. ADVERTENCIA 1) No mezcle ninguna sustancia que no sea el refrigerante especificado (R41 OA) en el circuito de refrigeración. 2) Si hay fugas de gas refrigerante, ventile la habitación tan pronto y tanto como sea posible. 3) El refrigerante R410A, así como otros refrigerantes, siempre se deben recuperar y nunca se deben liberar directamente al medio ambiente. 4) Utilice una bomba de vacío exclusivamente para el refrigerante R410A. El uso de la misma bomba de vacío para diferentes refrigerantes puede dañar dicha bomba o la unidad. • Si añade más refrigerante, realice una purga de aire en los tubos de refrigerante y la unidad interior utilizando una bomba de vacío y cargue después el refrigerante adicional. • Utilice una llave Allen (4 mm) para manipular la varilla de la válvula de retención. • Todas las uniones del tubo refrigerante se deben apretar con una llave dinamométrica con el par de torsión especificado. Conecte el lado de proyección de la manguera de carga (procedente del analizador) al puerto de servicio de la válvula de retención. Abra completamente la válvula de baja presión (Baja) del analizador y cierre totalmente su válvula de alta presión (Alta). Ya no tendrá que manipular la válvula de alta presión. Aplique la bomba de vacío. Compruebe que en el analizador de presión compuesto pone 0,1 MPa (-76 cmHg). Es recomendable que la bomba de vacío esté funcionando durante al menos una hora. Cierre la válvula de baja presión (Baja) del analizador y pare la bomba de vacío. Deje que transcurran entre 4 y 5 minutos y asegúrese de que la aguja del analizador no retrocede. Si retrocede, significa que hay humedad o fugas en los componentes unidos. Después de inspeccionar todas las conexiones y si hay alguna pieza suelta vuelva a apretar todas las tuercas y repita los pasos 2 a 4. Quite las tapas de la válvula de retención de líquido y de la válvula de retención de gas. Gire la varilla de la válvula de retención de líquido 90 grados en sentido contrario a las agujas del reloj con una llave Allen para abrirla. Ciérrela después de 5 segundos y compruebe si hay fugas de gas. Mediante agua jabonosa, compruebe si hay fugas de gas en los abocardados de las unidades interior y exterior y en las varillas de la válvula. Una vez realizadas todas las comprobaciones, quite el agua jabonosa. Desconecte la manguera de carga del puerto de servicio de la válvula de retención de gas y, a continuación, abra completamente las válvulas de retención de líquido y gas. (No intente girar más la varilla de la válvula una vez se haya detenido.)  Apriete las tapas de las válvulas y las tapas del puerto de servicio correspondientes a dichas válvulas con una llave dinamométrica con el par de apriete especificado. Consulte la sección "3 Acometida de los tubos de refrigerante" en la página 6 para obtener más detalles. Acometida de los tubos de refrigerante 5. Rellenar el refrigerante Compruebe el tipo de refrigerante que se debe utilizar en la placa de características de la máquina. Precauciones al añadir refrigerante R410A Rellene desde el tubo de líquido en forma de líquido. Se trata de un refrigerante mixto, por lo que si se añade en forma de gas, la composición de dicho refrigerante puede cambiar, lo que impedirá el funcionamiento normal del aparato. 1) Antes de rellenar el refrigerante, compruebe si la botella tiene acoplado un sifón (debe mostrar algo así como "sifón de relleno de líquido acoplado"). Rellenar otras botellas Rellenar una botella con un sifón acoplado Coloque la botella en posición vertical cuando la rellene. Hay un tubo con sifón el interior, por lo que no es necesario poner la botella boca abajo para rellenarla con líquido. Ponga la botella bocabajo cuando la rellene. 2) Asegúrese de utilizar las herramientas R410A para garantizar la presión y evitar que entren objetos extraños. 6. Cargar con refrigerante 1) El sistema debe utilizar refrigerante R410A. Unidad exterior 2) Añada 20 g de refrigerante por metro cuando la longitud total de los tubos de líquido supere el valor estándar, pero asegúrese de que dicha longitud es inferior al valor máximo. Longitud estándar Longitud total máxima total de los tubos de de los tubos de líquido líquido Notas: 1) Cuando utilice este producto, no es necesario establecer la dirección. Sin embargo, los cables UN entre las unidades interior y exterior se deben conectar correctamente o, de lo contrario, habrá un error de comunicación. 2) Establecimiento del funcionamiento en modo de silencio. Establezca el interruptor DIP "8" en la posición de encendido (ON) de SW5. El sistema funcionará con menor ruido pero la capacidad máxima también se reducirá ligeramente. 3) No cambie la configuración de los otros conmutadores ya que una mala configuración puede dañar el sistema o causar otras averías. 7. Precauciones para colocar los tubos de refrigerante • Precauciones a la hora de manipular los tubos 1) Proteja al extremo abierto del tubo del polvo y la humedad. 2) Todas las curvaturas de los tubos deben ser tan suaves como sea posible. Utilice una curvadora de tubos para curvar los tubos. El radio de curvatura debe ser de al menos 30 mm. • Selección del cobre y de los materiales aislantes del calor Cuando utilice tubos y accesorios de cobre comerciales tenga en cuenta lo siguiente: 1) Material aislante: espuma de polietileno. Tasa de transferencia de calor: 0,041 a 0,052 W/mK (0,035 a 0,045 kcal/mh °C) La temperatura de la superficie del tubo de gas refrigerante alcanza los 110 °C como máximo. Elija materiales aislantes de calor que soporten esta temperatura. 2) Asegúrese de aislar los tubos de gas y de líquido, y de proporcionar las dimensiones de aislante que se indican a continuación. Tubo de gas D.E: 9,52 mm,12, 7 mm Grosor: 0,8 mm Tubo de líquido D.E.: 6,35 mm Grosor: 0,8 mm 10 Aislante del tubo de gas D.I.: 12-15 mm, 12,7 mm Grosor: 13mm mínimo Aislante del tubo de líquido D.I.:18-10 mm Grosor: 10 mm mínimo Acometida de los tubos de refrigerante 3) Utilice tubos con aislante térmico independientes para los tubos de gas y de líquido refrigerante. Tubo de gas Cableado de la unidad interior Pared Asegúrese de colocar una tapa. Tubo de líquido Lluvia Si no hay una tapa para abocardado disponible, cubra la boca del abocardado con cinta para que no entre sociedad ni agua. Aislante del tubo de líquido Aislante del tubo de gas Embellecedor Manguera de desagüe Comprobar La superficie interior del abocardado no debe tener imperfecciones. El extremo del tubo debe estar abocardado uniformemente y formar un círculo perfecto. Corte exactamente en ángulos rectos. Eliminar las rebabas Asegúrese de que la tuerca abocardada está ajustada Colocar exactamente en la posición que se muestra a continuación. Abocardador para R410A De tipo acoplamiento Molde del abocardador 0-0,5mm Abocardador convencional De tipo acoplamiento De tipo palometa (tipo rígido) (tipo imperial) 1,0-1,5mm 1,5-2,0 mm 8. Corte y abocardado de los tubos • El corte de los tubos se realiza con un cortatubos e incluye la eliminación de las rebabas. • El abocardado se realiza después de introducir la tuerca abocardada. Tubo Lado de líquido Lado de Molde del abocardador gas Diámetro del tubo Tamaño A (mm) 6,35mm (1/4") 0.8-1.5 9,52mm (3/8") 1.0-1.5 12,7 mm (1/2") 1.0-1.5 Correcto Incorrecto Inclinado Abocardado dañado Grieta Parcial Demasiado fuera 9. Desagüe • Instale la manguera de desagüe formando una pendiente descendiente de forma homogénea. A continuación se muestran ejemplos de malas prácticas de desagüe. Menos de 5 cm Se alza a medio camino. El extremo está sumergido en agua. La separación respecto al suelo es demasiado pequeña. Está ondulado. Hay mal olor de una zanja • Deposite agua en la bandeja de desagüe de la unidad interior y confirme que el drenaje se realiza correctamente hacia fuera. • En caso de que la manguera de desagüe se encuentre en una habitación, asegúrese de aplicar aislante de calor uniformemente. ADVERTENCIA 1) No utilice aceite mineral en la pieza abocardada. 2) Evite que el aceite mineral entre en el sistema porque reducirá el período de vida útil de las unidades. 3) N unca utilice tubos que ya se hayan utilizado para instalaciones anteriores. Utilice solamente componentes proporcionados con la unidad. 4) Para garantizar el período de vida útil de esta unidad R410A nunca instale un secador en ella. 5) El material de secado puede disolver y dañar el sistema. 6) Un abocardado incompleto puede provocar fugas de gas refrigerante. 11 Funcionamiento de la bomba de vacío Para proteger el medio ambiente, asegúrese de realizar el vacío cuando cambie de emplazamiento la unidad o se deshaga de ella 1) Quite las tapas de la válvula de retención de líquido y de la válvula de Válvula de retención de líquido retención de gas. Llave Allen 2) Ponga en marcha el aparato en el modo de funcionamiento de refrigeración. 3) Después de diez minutos, cierre la válvula de retención de líquido con una llave Allen. Cerrar 4) Después de dos o tres minutos, cierre la válvula de retención de gas y detenga el funcionamiento del modo de refrigeración. Válvula de retención de gas Tapa de válvula Cableado 1. Cableado eléctrico • El aparato de aire acondicionado dede utilizar un circuito especial y el cableado debe ser realizado por un electricista profesional conforme a las normas estándar nacionales de cableado. • Es obligatorio separar el cable de tierra y el cable neutro. No se puede conectar el cable neutro con el cable de tierra. • Se debe instalar un interruptor de fugas eléctrico. • Todos los cables eléctricos deben ser de cobre. Fuente de alimentación: 1 PH, 220-230 V- y 50 Hz. • El método de cableado de la línea de alimentación debe ser una conexión en Y. Si la línea de alimentación está dañada, para evitar descargas eléctricas, debe ser reemplazada por el fabricante, por su centro de reparaciones o por otra persona similar capacitada. Fusible: T 3,15 A/250 VAC T 16 A/250 VCA (Compruebe el esquema de cableado de la unidad exterior). • Compruebe el esquema del circuito cuando vaya a cambiar el fusible. 2. Métodos de cableado • Método de cableado de terminales circulares. En el caso de cables de conexión con terminales circulares, el método de conexión debe ser el que se muestra en la figura de la derecha: quite el tonillo de conexión, páselo por la arandela situada en el extremo del cable y, a continuación, realice la conexión con el bloque de terminales y apriete el tornillo. Método de conexión de terminales cuadrados. • Para cables de conexión sin terminales circulares, el método de cableado es el siguiente: afloje el tornillo de conexión, inserte el extremo del cable de conexión completamente en el bloque de terminales y, a continuación, apriete el tornillo. Tire ligeramente del cable hacia afuera para confirmar que está firmemente sujeto. Método de cableado del bloque de terminales con arandela • Método de conexión de engarce para cables sin terminales Sujeción correcta Conecte cables con el mismo diámetro a ambos lados del terminal. No conecte cables con el mismo diámetro al mismo lado. No conecte cables con diferentes diámetros. Sujeción incorrecta Bloque de terminales Abrazaderas de sujeción • Método de conexión de engarce para el cable de conexión. Después de la conexión, el cable debe quedar sujeto por su cubierta. La cubierta del cable presionará el recubrimiento de protección del cable de conexión tal y como se muestra en la figura superior derecha. Nota: al conectar el cable, confirme el número de terminales de las unidades interior y exterior detenidamente. Si el cableado se realiza incorrectamente, el controlador del aire acondicionado resultará dañado o la unidad puede dejar de funcionar. 3. Método de cableado de la unidad exterior: • Línea de alimentación Retire la tarjeta de reparación de la unidad externa y afloje la cubierta del cable A. A continuación, coloque la fase, el neutro y la tierra a través de la cubierta del cable y conéctelos al bloque de terminales según corresponda. Después de la conexión, apriete la cubierta del cable para devolverla a su estado anterior. Cable de comunicación de la unidad interior. • Afloje la tapa del cable, coloque el cable de comunicación a través de la tapa de cable B y conéctelos al bloque de terminales según corresponda. Después de la conexión, apriete la cubierta del cable B para devolverla a su estado anterior. Nota: la línea de alimentación y el cable de comunicación no se incluyen. 12 Cableado Tapa de cable A Tapa de cable A Tapa de cable C Bloque de terminales Tapa de cable C Tapa de cable B Tapa de cable B Bloque de terminales Tapa de válvula –¨ Tapa de cable D Tapa de cable E Tapa de válvula 25.40 0 4. Método de cableado de la unidad interior Afloje la tapa del cable y conecte la línea de alimentación y el cable de comunicación de la unidad interior al terminal que corresponda. Nota: Cuando conecte la línea de alimentación al terminal de la fuente de alimentación preste especial atención a lo siguiente: • No conecte la línea de alimentación de diferentes tamaños al mismo terminal del cable de conexión. Un contacto inadecuado provocará sobrecalentamiento. • No conecte la línea de alimentación de diferentes tamaños al mismo terminal del cable de tierra. Un contacto inadecuado afectará a la protección. • No conecte la línea de alimentación al extremo de conexión del cable de comunicación. Una conexión incorrecta provocará daños en la unidad conectada. 5. Ejemplo del sistema de cableado. Para ver un esquema de cableado consulte 5U34HS1ERA Dé a los cables la forma debida para que no se levante la tapa del servicio ni otras piezas de la estructura. Fije el cableado de derivación firmemente mediante los 4 tornillos incluidos, tal y como se muestra en la figura. Fije las conexiones firmemente asegurándose de que no ejerce demasiada presión sobre los terminales. 13 Utilice los cables especificados y conéctelos de forma segura. Prueba del aparato • Antes de iniciar el funcionamiento de prueba asegúrese de que las siguientes tareas se han realizado correctamente. 1) Conexión correcta de todos los tubos; 2) Conexión correcta del cableado; 3) Correspondencia correcta de las unidades interior y exterior; 4) Recarga adecuada del refrigerante en caso de que sea necesario. • Asegúrese de que todas las válvulas de retención están completamente abiertas. • Compruebe el voltaje suministrado a las unidades exterior e interior y asegúrese de que su valor es de 230 V. • Compruebe los errores del cableado. Este producto es capaz de comprobar automáticamente los errores de cableado. Coloque en la posición de encendido los 4 conmutadores DIP de la pequeña tarjeta de circuito impreso de servicio de la unidad exterior tal y como se muestra a la derecha. A continuación, apague la unidad y vuelva a encenderla. El sistema entrará en el modo de funcionamiento "Comprobación de errores de cableado". Después de 3 minutos en el modo de espera, la unidad iniciará la comprobación automática del cableado. Aproximadamente 30 ~ 50 minutos después (en función del número de unidades instaladas en el sistema) la unidad arrancará y los errores de cableado se mostrarán en los LED (1 a 5). Durante esta operación, el número digital mostrará alternativamente la frecuencia de trabajo del compresor (por ejemplo, 50 significa la frecuencia de funcionamiento actual y las letras CH significan comprobación). Después de esta operación, si todo el cableado es correcto, el número digital mostrará "0". Si hay algún error de cableado, el número digital mostrará "EC" (error de conexión) y, al mismo tiempo, parpadeará. Los LED de supervisión de servicio indican el error del cableado tal y como se muestra en la tabla siguiente. Para obtener detalles sobre cómo leer los LED, consulte el manual de servicio. Si no es posible realizar la comprobación automática, compruebe el cableado y la conexión de los tubos de la unidad interior manualmente. LED 1 Estado ENCENDIDO ENCENDIDO 2 3 APAGADO 4 5 Mensaje Unidad no conectada No es posible realizar la comprobación automática; error de TODOS intermitentes conexión en todas las unidades. Todas las unidades están TODOS ENCENDIDOS correctamente conectadas ENCENDIDO: unidad correctamente conectada INTERMITENTE: unidad INTERMITENTE INTERMITENTE ENCENDIDO INTERMITENTE incorrectamente conectada. Es necesario cambiar el cableado manualmente entre 2, 3 y 5. ENCENDIDO: unidad correctamente conectada INTERMITENTE: unidad INTERMITENTE INTERMITENTE ENCENDIDO ENCENDIDO incorrectamente conectada. Es necesario cambiar el cableado manualmente entre 2 y 3. Solamente un LED intermitente Anomalía. • Prueba del aparato. 1) Si la temperatura es inferior a 16 ºC, es posible comprobar la refrigeración con el mando a distancia. Asimismo, cuando la temperatura es superior a 30 ºC, es posible comprobar el modo de funcionamiento de calefacción. 2) Para comprobar el modo de refrigeración, establezca la temperatura más baja en 16 °C.Para comprobar el modo de calefacción, establezca la temperatura más alta en 30 . 3) Compruebe tanto el modo de funcionamiento de refrigeración como el modo de funcionamiento de calefacción de cada unidad individualmente y, a continuación, compruebe también el funcionamiento simultáneo de todas las unidades interiores. 4) Después de que la unidad haya estado funcionando durante 20 minutos compruebe la temperatura de salida de la unidad interior. 5) Cuando la unidad se detenga o el modo de trabajo cambie, el sistema no se volverá a iniciar hasta que transcurran aproximadamente 3 minutos. 6) En el modo de funcionamiento de refrigeración, se puede producir escarcha en la unidad interior o en los tubos, lo cual es normal. 7) Utilice la unidad conforme al manual de funcionamiento. Explique al cliente cómo utilizar el aparato utilizando el manual de instrucciones. • Pantalla numérica de siete segmentos 1) Cuando la unidad está funcionando, esta pantalla numérica de siete segmentos muestra la frecuencia del compresor. Por ejemplo, " significa que la frecuencia de " " significa que la frecuencia de funcionamiento del compresor es 40 Hz. " funcionamiento del compresor es 108 Hz. 2) Si se produce un error, la pantalla numérica de siete segmentos parpadeará y mostrará números; estos números corresponden a códigos de error. Por ejemplo, si aparece " " parpadeando, significa el error nº 32, que es un error de comunicación entre las unidades interior y exterior. • LED de comunicación 5 LED de color verde significan 5 unidades interiores. Si un LED se mantiene iluminado significa que la unidad interior correspondiente tiene buena comunicación con la unidad exterior. Si un LED no se ilumina, significa que no hay comunicación entre las unidades interior y exterior. 14 Resolución de problemas Razones posibles Visualización de LED exterior Visualización de casete y visualización convertible interior y exterior có controlador con Lámpara de temporizador Lámpara de funcionamiento cable Veces de destello Veces de destello Falla de la unidad exterior EEPROM 1 15 2 1 Sobrecorriente o cortocircuito de IPM 2 16 2 2 Falla de comunicación entre módulo y ECU. Cables de comunicación están rotos o no están bien conectados. Sobrecarga de módulo operado 4 18 2 4 5 19 2 5 6 1A 2 6 8 1C 2 8 Módulo de voltaje DC bajo o alto (bajo 192V o superior a 375V) Sobrecalentamiento de la temperatura de descarga. Falta de refrigerante, la temperatura del ambiente es demasiada alta o PMVs está bloqueado. Mal funcionamiento del motor DC del ventilador . 9 1D 2 9 Mal funcionamiento del sensor de la temperatura de descongelación. 10 1E 3 0 Mal funcionamiento del sensor de la temperatura de succión del compresor. 11 1F 3 1 Mal funcionamiento del sensor de la temperatura del ambiente. 12 20 3 2 Mal funcionamiento del sensor de la temperatura de descarga del compresor. 13 21 3 3 Falla de comunicación entre la unidad interior y exterior. 15 23 3 5 Falta de freón 16 36 3 6 Falla de conmutación de la válvula de 4 vías. 17 25 3 7 Sobrecorriente de módulo /Falla de conmutación de módulo 18 26 3 8 Sobrecarga interior 20 28 4 0 Helado de interior 21 29 4 1 Temperatura demasiada alta del módulo (Protector de sobrecarga) 23 2B 4 3 Sobrecarga del compresor 24 2C 4 4 Sobrecorriente de entrada 25 2D 4 5 Reestablecimiento de MCU 26 2E 4 6 Corriente de módulo detecta el mal funcionamiento del circuito 27 2F 4 7 Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad interior A Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad interior B Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad interior C Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad interior D Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad interior A Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad interior B Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad interior C Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad interior D Mal funcionamiento del sensor de la temperatura del tubo de gas para la unidad interior E Mal funcionamiento del sensor de la temperatura de módulo 28 30 4 8 29 31 4 9 30 32 5 0 31 33 5 1 32 34 5 2 33 35 5 3 34 36 5 4 35 37 5 5 36 38 5 6 38 3A 5 8 Mal funcionamiento del sensor de la temperatura de condensación 39 3B 5 9 Mal funcionamiento del sensor de la temperatura del tubo de líquido para la unidad 40 interior E Mal funcionamiento del sensor de la temperatura del tubo 41 3C 6 0 3D 6 1 Apagado el interruptor del sistema de presión alta 42 3E 6 2 Apagado el interruptor del sistema de presión baja 43 3F 6 3 Protección del sistema de presión alta. Exceso de refrigerante, temperatura alta de 44 condensación o mal funcionamiento del motor de ventilador. Protección del sistema de presión baja. Escasez de refrigerante, temperatura baja 45 de descongelación o mal funcionamiento del motor de ventilador. Mal funcionamiento del sensor de la temperatura del módulo 46 40 6 4 41 6 5 42 6 6 15 Dirección: No.1 Haier Road, Hi-tech Zone.Qingdao 266101 República Popular China Contactos: TEL: +86-532-8893-6943; FAX: +86-532-8893-6999 Sitio web: www.haier.com MANUALE D’INSTALLAZIONE DEL CONDIZIONATORE DI TIPO MULTI-SPLIT Precauzioni di sicurezza--------------------- 3 Accessori - ------------------------------------- 4 Precauzioni per la selezione del luogo d’installazione---------------------------------- 4 Schema per l’installazione dell’unità interna ed esterna----------------------------- 5 Precauzioni per l’installazione-------------- 7 Linee guida per l’installazione dell’unità esterna------------------------------- 7 Limitazioni per l’installazione--------------- 7 Tubature del refrigerante-------------------- 7 Operazioni di scarico -----------------------12 Collegamento dei cavi elettrici------------12 Test-----------------------------------------------14 Risoluzione dei problemi -------------------15  Leggere con attenzione questo manuale prima dell'installazione. Conservare questo manuale per riferimenti futuri. Italiano Indice Haier Industrial Park, N.1 Haier Road, Qingdao, Repubblica Popolare Cinese CONFORMITÀ AI REGOLAMENTI EUROPEI PER I MODELLI IMPORTANTI INFORMAZIONI RELATIVE AL REFRIGERANTE UTILIZZATO CE Tutti i prodotti sono conformi alle seguenti disposizioni europee: - Direttiva bassa tensione 73/23/CEE - Direttiva bassa tensione 2006/95/CEE - Compatibilità elettromagnetica 89/336/CEE - Compatibilità elettromagnetica 2004/108/CE ROHS I prodotti sono conformi ai requisiti della direttiva 2002/95/CEE del Parlamento e del Consiglio Europeo sulla limitazione dell'uso di alcune sostanze pericolose nei dispositivi elettrici ed elettronici (Direttiva RoHS UE). WEEE In conformità alla direttiva 2002/96/CE del Parlamento Europeo, informiamo il consumatore relativamente ai requisiti per lo smaltimento dei prodotti elettrici ed elettronici. REQUISITI PER LO SMALTIMENTO: Il condizionatore è marchiato con questo simbolo. Ciò significa che i prodotti elettrici ed elettronici non devono essere smaltiti insieme ai rifiuti urbani indifferenziati. Non tentare di aprire il sistema da soli: Lo smantellamento del sistema di condizionamento, il trattamento del refrigerante, dell’olio e di altre parti, deve essere eseguito da un tecnico qualificato in conformità alle norme locali e nazionali. I condizionatori devono essere trattati presso strutture di trattamento specializzate per il riutilizzo, il riciclaggio e recupero. Assicurandosi che questo prodotto sia smaltito in mood appropriato si aiuterà nella prevenzione di potenziali effetti negativi sull’ ambiente e sulla salute umana. Contattare l'installatore o l'autorità locale per ulteriori informazioni. Le batterie usate del telecomando devono essere smaltite separatamente in conformità alle norme locali e nazionali. Questo prodotto contiene gas serra fluorinato, trattato nel Protocollo di Kyoto Kg Kg Kg Questo prodotto contiene gas serra fluorinato, oggetto del Protocollo di Kyoto. Non lasciar sfogare nell'atmosfera. Tipo di refrigerante: R410A Valore GWP*: 1975 GWP=global warming potential Inserire, con inchiostro indelebile, •1 il carico di refrigerante del prodotto inserito in fabbrica •2 il quantitativo aggiuntivo di refrigerante caricato sul campo e • 1+2 Il totale di refrigerante caricato sull'etichetta di caricamento del refrigerante fornita col prodotto. L'etichetta compilata deve essere attaccata accanto alla porta di caricamento del prodotto (es. all'interno del coperchio con il valore di arresto). A questo prodotto contiene gas serra fluorinato, trattato nel Protocollo di Kyoto B carico di refrigerante del prodotto inserito in fabbrica: vedere la piastra con il nome dell'unità C Il refrigerante aggiuntivo caricato durante l'installazione D Il totale di refrigerante caricato E Unità esterna F F cilindro di refrigerante e collettore per la carica Precauzioni di sicurezza • Leggere accuratamente queste Precauzioni per la sicurezza per garantire la corretta installazione. • Questo Manuale classifica le precauzioni in AVVISO E ATTENZIONE. • Accertarsi di osservare tutte le precauzioni che seguono: sono tutte importanti per garantire la sicurezza. AVVISO La mancata osservanza di qualsiasi AVVISO può provocare gravi conseguenze come lezioni o morte. ATTENZIONE La mancata osservanza di qualsiasi richiamo all’ATTENZIONE in alcuni casi può provocare gravi conseguenze. • In questo manuale sono usati i simboli che seguono: Assicurarsi di osservare queste istruzioni. Assicurarsi si eseguire la messa a terra. Non tentare mai. • ����������������������������������������������������������������������������������������������������������������� � D �������������������������������D guate riguardo all’uso ed alla pulizia dell’unità come indicato nel Manuale d’uso. AVVISO • L’installazione deve essere eseguita dal rivenditore o da altro professionista. L’installazione inappropriata può provocare perdite d’acqua, scariche elettriche o incendi. • Installare il condizionatore osservando le istruzioni date in questo Manuale. L’installazione incompleta può provocare perdite d’acqua, scariche elettriche o incendi. • Assicurarsi di usare i pezzi forniti in dotazione o specificati. L’uso di altri pezzi può provocare l'allentamento dell’unità, perdite d’acqua, scariche elettriche o incendi. • Installare il condizionatore su una base solida che possa supportare il peso dell’unità. Una base inadeguata o un’installazione incompleta può provocare lesioni in seguito alla caduta dell’unità dalla base. • ������������������������������������������������������������������������������������������������������������������������������������������������ Una conoscenza insufficiente della materia o un lavoro elettrico incompleto può provocare scariche elettriche o incendi. • Accertarsi di usare un circuito elettrico dedicato. Non usare mai sorgenti d’alimentazione condivise con altre attrezzature. • Per i collegamenti elettrici, usare cavi sufficientemente lungi da coprire l’intera distanza senza eseguire collegamenti. Non usare prolunghe. Non caricare la sorgente d’alimentazione con altri carichi ed usare un circuito dedicato. (Diversamente si può provocare surriscaldamento animalo, scariche elettriche e incendi.) • Usare i tipi di cavo specificati per i collegamenti elettrici tra l’unità interna ed esterna. Fissare in sicurezza i cavi di collegamento così che i terminali non subiscano stress esterni. Il collegamento o fissaggio incompleto può provocare il surriscaldamento dei terminali o incendi. • ���������������������������������������������������������������������������������������������������������������������������������������� coperchi o pannelli delle scatole. Installare i coperchi sopra i cavi. L’installazione incompleta dei coperchi può provocare il surriscaldamento dei terminali, scariche elettriche e incendi. • Se il gas refrigerante è fuoriuscito durante le operazioni di installazione, aerare il locale. (Il refrigerante produce gas tossici se esposto alle fiamme.) • Al termine dell’installazione assicurarsi che non ci siano perdite di refrigerante. (Il refrigerante produce gas tossici se esposto alle fiamme.) • ��������������������������������������������������������������������������������������������������������������������������������������������� specificato (R410A), come l’aria. (La presenza di aria o di altre sostanze estranee nel circuito del refrigerante provoca un anomalo aumento della pressione o rotture, causando lesioni.) • Per le operazioni di scarico, arrestare il compressore prima di rimuovere il refrigerante. Se il compressore è ancora in funzione e la valvola d’arresto è aperta durante lo scarico, l’aria sarà aspirata provocando una pressione anomala nel ciclo di raffreddamento che porterà a rotture e lesioni. • Assicurarsi di eseguire la messa a terra. Non collegare il cavo di messa a terra a tubature delle utenze, parafulmini o linee telefoniche. Una messa a terra inappropriata può provocare scariche elettriche o incendi. L’alta tensione dei fulmini o di altre origini può provocare danni al condizionatore. • Assicurarsi di installare un salvavita. La mancata installazione del salvavita può provocare scariche elettriche o incendi. ATTENZIONE • Non installare il condizionatore in luoghi dove c’è il pericolo di esposizione a pericolose perdite di gas infiammabili. Se il gas si accumula attorno all’unità c’è il pericolo di incendi. • Posare il tubo di scarico come da istruzioni di questo Manuale. La posa inadeguata dei tubi può provocare allagamenti. • Stringere il dado svasato usando il metodo specificato come una chiave dinamometrica. Se il dado svasato è stretto troppo, col tempo può spaccarsi e provocare la perdita di refrigerante. • ���������������������������������������������������������������������������������������������������������������� Piccoli animali possono entrare nell’unità ed entrare in contato con le parti elettriche provocando guasti, fumo o incendi. Istruire il cliente di tenere pulita e sgombra l’area attorno all’unità.  Accessori Accessori forniti in dotazione all’unità interna: N. Diagramma Nomi delle parti Quantità Nota 1 1 Curvetta di scarico 2 Gommino 3 4 1 3 Bullone 3 4 Ancora (3/8 1/2) 1 5 Ancora (1/2 3/8) 1 Precauzioni per la selezione del luogo d’installazione 1) Scegliere un luogo sufficientemente forte per supportare il peso e le vibrazioni dell’unità e dove il rumore di funzionamento non sia amplificato. 2) Scegliere un luogo dove l’aria calda scaricata dall’unità ed il rumore di funzionamento non siano di disturbo ai vicini. 3) Evitare loghi vicini a stanze da letto e simili, così che il rumore di funzionamento non causi disagi. 4) Ci deve essere spazio sufficiente per installare e rimuovere l’unità. 5) Ci deve essere spazio sufficiente per il ricircolo dell’aria e non ci devono essere ostruzioni attorno alla presa ed allo scarico dell’aria. 6) Nelle vicinanze non ci devono essere evenienze di perdite di gas infiammabili. Installare l’unità in modo che il rumore e l’aria scaricata non disturbino i vicini. 7) Installare le unità, i cavi d’alimentazione ed i cavi di collegamento ad una distanza di almeno 3 metri da televisori e radio. Questo per prevenire interferenze audio e video. (I disturbi possono essere notati anche a più di 3 metri di distanza, in base alle condizioni delle onde radio.) 8) Nelle zone costiere ed altre aree con concentrazioni saline o di solfati nell’aria, la corrosione può accorciare la durata del condizionatore. 9) Poiché lo scarico esce dall’unità esterna, non collocare sotto l’unità qualsiasi cosa che deve stare lontana dall’umidità. NOTA: Non deve essere istallato al soffitto o impilato. ATTENZIONE  Quando si usa il condizionatore e la temperature esterna è bassa, assicurarsi si osservare le istruzioni che seguono. 1) Per impedire l’esposizione ai venti, installare l’unità esterna con la sua presa d’aria rivolta verso la parete. 2) Non installare mai l’unità esterna in luoghi dove la presa d’ aria può essere esposta ai venti. 3) Per prevenire l’esposizione ai venti, si raccomanda di installare un deflettore sul alto di scarico dell’aria dell’unità esterna. 4) Nelle aree soggette a forti nevicate, selezionare un luogo dove la neve non interessa l’unità. • • Costruire un ampio riparo. Costruire un piedistallo. Installare l’unità sufficientemente sollevata dal terreno per impedire che sia sepolta dalla neve. Schema per l’installazione dell’unità interna ed esterna L’illustrazione fa riferimento al modello 4U30HS1ERA più di 10 cm più di 5 cm 1. Assicurarsi che nel tubo di diramazione non penetrino sporcizia né umidità. 2. Al sistema devono essere collegate almeno due unità. Disposizione della direzione delle tubature Posteriore sinistra Sinistra Posteriore destra Destra Inferiore Deve essere prestata attenzione al sollevamento del tubo flessibile di scarico Avvolgere il tubo isolante col nastro partendo dal basso e procedendo verso l’alto. Tagliare il tubo d’isolamento termico ad una lunghezza appropriata ed avvolgerlo col nastro, assicurandosi di non lasciare spazi sulla linea ti taglio. 10 cm più di più di 10 c m più m 5c 2 di cm i 60 d ù pi  Se c’è il pericolo che l’unità cada o si capovolga, fissarla con bulloni alla base, oppure con dei cavi o altri mezzi appropriati. Se il luogo d’installazione non permette un buon scarico dell’acqua, collocare l’unità su una base piatta (o un piedistallo di plastica). Installare l’unità esterna in posizione piatta. Diversamente si possono provocare perdite o accumulo dell’acqua. Schema per l’installazione dell’unità interna ed esterna Avvisi per il collegamento dei cavi Modello 4U26HS1ERA 4U30HS1ERA 3U19FS1ERA 3U24GS1ERA 5U34HS1ERA Priorità di collegamento tra unità interna e valvola d’arresto * più in alto C D E Quando c’è 1 unità interna, la priorità di valvola Quando ci sono 2 unità CB DC ED interne, la priorità di valvola Quando ci sono 3 unità CBA DCB EDC interne, la priorità di valvola Quando ci sono 4 unità DCBA EDCB interne, la priorità di valvola Quando ci sono 5 unità EDCBA interne, la priorità di valvola Nota: Per una migliore circolazione dell’olio e per sistema più affidabile, attenersi a quanto esposto in precedenza quando si collega l’unità interna.  Precauzioni per l’installazione • ��������������������������������������������������������������������������������������������������������������������������������������� • ���������������������������������������������������������������������������������������������������������������������������������� 8 �� o �� M10, dadi e rondelle che sono disponibili sul mercato.) • �������������������������������������������� ������������������������������ �0 � mm dalla superficie della base. Linee guida per l’installazione dell’unità esterna • ������������������������������������������������������������������������������������������������������������������������������������ • ������������������������������������������������������������������������������������������������������������������������������������ meno. Muro rivolto su un lato Più di 300 Più di 50 1200 o inferiore Veduta laterale Muro su tre lati Muro rivolto su due lati Più di 100 Più di 150 Più di 300 Più di 300 Più di 50 Più di 100 Veduta laterale Più di 50 Veduta laterale Limitazioni per l’installazione 1. Precauzioni per l’installazione • ��������������������������������������������������������������������������������������������������������������������������������������� • Facendo riferimento al diagramma d’installazione, fissare in sicurezza l’unità usando dei bulloni. • Si consiglia di stringere i bulloni finché la loro lunghezza si riduce a 20 mm dalla superficie della base. 2. Selezione del luogo d’installazione per le unità interne • ������������������������������������������������������������������������������������������������������������������������������� esterna e le unità interne. (Più corto è il tubo del refrigerante, migliori sono le prestazioni. Collegare in modo che il tubo sia il più corto possibile. La lunghezza minima consentita per stanza è di 3 m) Classe di capacità dell’unità esterna al massimo al massimo al massimo al massimo Lunghezza totale dei tubi tra tutte le unità al massimo al massimo al massimo al massimo  Tubi a ciascuna unità interna Limitazioni per l’installazione Unità interna Unità da esterno Dislivello: 15m al massimo Dislivello: 15m al massimo Dislivello: 7.5m al massimo Dislivello: 7.5m al massimo Unità da esterno Unità interna Se l’unità esterna è più alta delle unità interne. (Se più bassa di una o più unità.) Se l’unità esterna è più alta delle unità interne. Unità interna Dislivello: 15m al massimo Dislivello: 7.5m al massimo Unità da esterno Se l’unità interna è più alta delle unità esterne. Tubature del refrigerante 1. Installazione dell’unità esterna 1) Quando si installa l’unità esterna, fare riferimento alle sezioni "Precauzioni per la selezione del luogo d’installazione" e "Disegni per l’installazione dell’unità interna/esterna". 2) Attenersi alla procedura che segue se è necessario eseguire lo scarico dell’acqua. 2. Scarico dell’acqua 1) Usare l’attacco dello scarico per lo scarico. 2) Se l’attacco dello scarico è coperto dalla base o dalla superficie del pavimento, aggiungere uno spessore per sollevare di almeno 30 mm l’unità esterna. 3) Nelle arre particolarmente fredde, non usare tubi di scarico con l’unità esterna. (Diversamente l’acqua può ghiacciare nel tubo, compromettendo le prestazioni di riscaldamento.) Tubo Tubo Curvetta di scarico  Curvetta di scarico Tubature del refrigerante 3. Tubature del refrigerante 1) ����������������������������������������������������������������������������������������������������������������������������������� una chiave dinamometrica. Usare la chiave dinamometrica quando si stringono i dadi svasati per prevenire danni ai dadi e perdite di gas. Coppia di serraggio dei dadi svasati Dado svasato per 6.35 14.2-17.2N.m (144-175kgf.cm) Dado svasato per 9,52 32.7-39.9N.m (333^07kgf.cm) Dado svasato per 12,7 49.5-60.3N.m (505-615kgf.cm) Dado svasato per 15.88 61.8-75.4N.m (630-769kgf.cm) Coppia di serraggio tappo valvola Tubo del liquido 26.5-32.3N.m (270-330kgf.cm) Tubo del gas 48.1-59.7N.m (490-610kgf.cm) Lubrificare qui con olio per refrigerante Chiave dinamometrica Chiave per bulloni Coppia di serraggio tappo porta di servizio Raccordo Dado conico 10.8-14.7N.m (110-150 kgf.cm) 2) ������������������������������������������������������������������������������������������������������������������������������������ refrigerante R410A) 4. Sfiato dell’aria e controllo delle perdite di gas Al termine della posa dei tubi, è necessario sfiatare l’aria e controllare che non ci siano perdite di gas. AVVISO 1) Non miscelare sostante diverse dal refrigerante specificato (R41 OA) nel ciclo di refrigerazione. 2) Nel caso si verifichi una perdita di refrigerante, ventilare il più possibile la stanza. 3) Il refrigerante R410A, come anche antri refrigeranti, devono essere sempre recuperati e non devono mai essere smaltiti direttamente nell’ambiente. 4) Usare una pompa per il vuoto apposita per R41 OA. L’uso della stessa pompa per il vuoto per vari tipi di refrigeranti può danneggiare la pompa o l’unità. • �������������������������������������������������������������������������������������������������������������������������������������� pompa a vuoto, poi caricare il refrigerante. • ������������������������������������������������������������������������ • ����������������������������������������������������������������������������������������������������������������������� Collegare il tubo di caricamento (che esche dal manometro) alla porta di servizio della valvola d’arresto. Aprire completamente la valvola di bassa pressione (Lo) del manometro e chiudere completamente la sua valvola dell’alta pressione (Hi). (In seguito la valvola dell’alta pressione non richiede altre operazioni.) Avviare la pompa per il vuoto. Controllare che il manometro indichi 0.1 MPa (-76cmHg). Si raccomanda l’evacuazione per almeno 1 ora. Chiudere la valvola di bassa pressione (Lo) del manometro ed arrestare la pompa per il vuoto. (Lasciare com’è per 4-5 minuti ed accertarsi che l’indicatore del manometro non torni indietro. Se torna indietro significa che c’è della condensa oppure delle perdite sui raccordi. Dopo avere ispezionato tutti i raccordi ed avere allentato e stretto di nuovo i dadi, ripetere le istruzioni di cui ai punti 2-4.) Rimuovere il tappo dalla valvola d’arresto del liquido e del gas. Girare di 90 gradi la leva della valvola d’arresto del liquido usando una chiave esagonale per aprire la valvola. Chiuderla dopo 5 secondi e controllare se ci sono perdite di gas. Usando dell’acqua saponata, controllare se ci sono perdite di gas sulle svasature dell’unità interna, esterna e delle valvole. Al termine del controllo, pulire tutta l’acqua saponata. Scollegare il tubo di caricamento del gas dalla porta di servizio della valvola d’arresto, poi aprire completamente le valvole d’ arresto del liquido e de gas. (Non tentare di girare la leva della valvola d’arresto oltre il suo fine corsa.)  Stringere i tappi delle valvole ed il tappo della porta di servizio delle valvole d’arresto del liquido e del gas usando una chiave dinamometrica alla coppia specificata. Fare riferimento alla sezione "3 Tubature del refrigerante", a pagina 6, per i dettagli. Tubature del refrigerante 5. Rabboccare il refrigerante Verificare il tipo di refrigerante da usare sull’etichetta apposta sulla macchina. Precauzioni per quando si aggiunge il refrigerante R410A Riempire dal tubo del liquido in forma liquida. È un refrigerante miscelato, quindi aggiungerlo in forma gassosa può provocare il cambiamento della composizione del refrigerante, impedendo il normale funzionamento. 1) Prima di rabboccare, verificare se la bombola è dotata di sifone. (Ci deve essere una dicitura del tipo "Sifone per il rabbocco in dotazione".) Riempimento di altre bombole Riempimento di una bombola dotata di sifone La bombola deve stare dritta durante il riempimento. Capovolgere a bombola durante il riempimento. All’interno c’è un sifone, quindi la bombola non deve essere capovolta per essere riempita. 2) Assicurarsi di usare attrezzi R41 OA per garantire la pressione ed impedire l’accesso di oggetti o sostanze estranee. 6. Caricamento del refrigerante Lunghezza standard Unità da esterno 1) Questo sistema deve usare refrigerante R410A. tubi del liquido 2) Aggiungere 20g di refrigerante per metro quando la lunghezza totale dei tubi eccede il valore standard, però accertarsi che la lunghezza totale dei tubi per liquidi non ecceda il valore massimo. Lunghezza massima tubi del liquido Nota: 1) Non è necessario ipostare l’indirizzo quando si usa questo prodotto. Tuttavia i cavi UN che collegano le unità interne ed esterna devono corrispondere, diversamente ci sarà un errore di comunicazione. 2) Impostazione modalità silenziosa. Impostare DIP "8" di SW5 sulla posizione ON, il sistema funzionerà in modalità silenziosa, tuttavia la capacità massima sarà leggermente ridotta. Non modificare l’impostazione degli altri interruttori, l’impostazione scorretta può provocare danni al sistema o altri guasti. 7. Precauzioni per la posa dei tubi del refrigerante • Precauzioni sulla manipolazione dei tubi 1) Proteggere l’estremità aperta del tubo da polvere e umidità. 2) ����������������������������������������������������������������������������������������������������������������������������� deve essere di 30 - 40 mm o maggiore.) • Selezione del rame e dei materiali isolanti Osservare quanto segue quando si usando tubi e raccordi di rame commerciali: 1) Materiali d’isolamento: Schiuma di polietilene ���������������������������������������������������������������������������������������� °C) ���� La superficie del tubo del refrigerante raggiunge una temperatura massima di 110° C. Scegliere materiali isolanti che possono sopportare questa temperatura. 2) Assicurarsi di isolare i tubi del gas ed i tubi del liquido e di fornire l’isolamento come segue. Tubo per gas Diametro esterno: 9,52 mm, 12,7 mm Spessore: 0,8 mm Tubo per liquidi Diametro esterno: 6,35 mm Spessore: 0,8 mm 10 Isolamento tubi del gas Diametro interno: 12-15 mm, 12,7 mm Spessore: 13 mm minimo Isolamento tubi del liquido Diametro interno: 18-10 mm Spessore: 10mm minimo Tubature del refrigerante 3) Usare tubature isolate termicamente separati per i tubi del gas e del refrigerante liquido. Collegamento dei cavi elettrici dell’unità interna Tubo per gas Tubo per liquidi Pioggia Se non è disponibile un tappo svasato, coprire la svasatura con del nastro per impedire che la sporcizia o la pioggia penetrino all’interno. Isolamento tubi del liquido Isolamento tubi del gas Nastro di finitura Parete Assicurarsi di mettere un tappo. Tubo flessibile di scarico Controllo La superficie interna della svasatura deve essere impeccabile. L’estremità del tubo deve essere svasata uniformemente in un cerchio perfetto. Tagliare esattamente ad angolo retto. Rimuovere le sbavature Assicurarsi di installare i dadi svasati Posare esattamente nella posizione indicata di seguito. Profilo attrezzo per svasatura Attrezzo per sva- Attrezzo convenzionale per svasatura satura per R410A Tipo a frizione Tipo a frizione�������������� Tipo ad alette����������������� 0 - 0,5 mm 1.0 - 1,5 mm 1,5 - 2,0 mm 8. Taglio e svasatura dei tubi • Il taglio dei tubi si esegue con un tagliatubi e le fresature devono essere rimosse. • Dopo avere inserito il dado svasato, si esegue il lavoro di svasatura. Tubo Lato del liquido Lato del gas Profilo attrezzo per svasatura Diametro del tubo Dimensione A (mm) 6,35mm (1/4") 0.8-1.5 9,52mm (3/8") 1.0-1.5 12.7mm (1/2") 1.0-1.5 Corretto Scorretto Inclinato Danno della svasatura Rottura Parziale Troppo esterno 9. Sullo scarico • Installare il tubo flessibile di scarico in modo che sia inclinato correttamente verso il basso. Non installare lo scarico come mostrato di seguito. Inferiore a 5cm A mezza via si solleva. L'estremità è immersa nell'acqua Lo spazio tra l'estremità ed il terreno è troppo piccolo. È ondulato. Ci sono cattivi odori che provengono da uno scolo. • Versare dell'acqua nel raccoglitore dell'unità interna ed accertarsi che sia scaricata in sicurezza all'esterno. • Se il tubo di scarico collegato si trova in una stanza, isolarlo in modo appropriato. AVVISO 1) 2) 3) 4) 5) 6) Non usare oli minerali sulle svasature. Impedire all’olio minerale di penetrare nel sistema perché ridurrebbe la durata delle unità. Non usare mai tubature che sono state usate in precedenti installazioni. Usare solo le parti fornite in dotazione all’unità. Non installare mai materiali asciuganti su questa unità R41 OA per garantire a sua durata. I materiali asciuganti possono dissolvere e danneggiare il sistema. La svasatura incompleta può provocare perdite di gas refrigerante. 11 Operazioni di scarico Per proteggere l’ambiente, assicurarsi di scaricare il refrigerante quando si trasloca o si smaltisce l’unità. 1) Rimuovere il tappo dalla valvola d’arresto del liquido e del gas. 2) Eseguire la procedura di raffreddamento forzato. Valvola di interruzione 3) Dopo circa cinque, dieci minuti, chiudere la valvola d’arresto del liquido del liquido usando una chiave esagonale. 4) Dopo circa due, tre minuti, chiudere la valvola d’arresto del gas ed arrestare la procedura di raffreddamento forzato. Valvola di interruzione del gas Chiave esagonale Chiuso Tappo della valvola Collegamento dei cavi elettrici 1. Collegamento dei cavi elettrici • ����������������������������������������������������������������������������������������������������������������������������������������ficato in osservanza delle norme nazionali specifiche. • ��������������������������������������������������������������������������������������������������������������������������������sa a terra non è corretto. • ���������������������������������������������������������������������������� • ����������������������������������������������������������� �������������������������������������������������������������������������������� Y � che, deve essere sostituito dal produttore o dal suo Centro assistenza o altra personal similarmente qualificata. I cavi di collegamento devono essere schermati. Fusibile: T3.15A250VAC T16A250VAC (verificare usando il diagramma di collegamento dell’unità esterna.) • ��������������������������������������������������������������������������������������������������� 2. Metodo di collegamento • ������������������������������������������������������������������������������ cavi ai terminali circolari è mostrato nella figura sulla destra: Rimuovere la vite, infilare la vite attraverso l’anello al termine del cavo, collegare la blocco terminali e poi stringere la vite. Metodo di collegamento dei terminali dritti. • ��������������������������������������������������������������������������������������� completamente l’estremità del cavo di collegamento nel blocco terminali e poi stringere la vite. Tirare delicatamente il cavo verso l’esterno per accertarsi che sia fissato in sicurezza. • Metodo di collegamento a crimpaggio per i cavi senza terminali Collegare il cavo dello stesso diametro ai due lati del terminale Non collegare il cavo dello stesso diametro sullo stesso lato Non collegare cavi di diametro diverso Metodo di collegamento per blocco terminali circolari Pressione corretta Pressione non corretta Blocco terminali Pressione dei morsetti • ���������������������������������������������������������������� ������������������������������������������������������������ � copricavo. Il copricavo deve premere sulla guaina protettiva del cavo di collegamento, come mostrato nell’immagine di cui sopra. ����������������������������������������������������������������������������������������������������������������������������������� scorretto dei cavi provocherà danni al telecomando del condizionatore e l’unità non funzionerà. 3. Il metodo di collegamento dei cavi dell’unità interna: • Linea elettrica ���������������������������������������������������������������������������������������������������������������������������������������� '� di massa, neutro e di messa a terra, e poi collegare appropriatamente i cavi al blocco terminali. Dopo il collegamento, rimettere e fissare il coperchio della scatola dei cavi. Cavo di comunicazione dell’unità interna. • ���������������������������������������������������������������������������������������������������������� B � �������������������������������tamente al blocco terminali. Dopo il collegamento, rimettere e fissare il coperchio B della scatola dei cavi. Nota: Il cavo elettrico ed il cavo di comunicazione sono forniti dall’utente stesso. 12 Collegamento dei cavi elettrici Coperchio scatola dei cavi A Coperchio scatola Coperchio scatola dei cavi C dei cavi A Coperchio scatola Blocco terminali dei cavi B Blocco terminali Coperchio scato- Coperchio scatola Coperchio scatola dei cavi E la dei cavi B dei cavi D Coperchio valvola –¨ Coperchio scatola dei cavi C Coperchio valvola 25.40 0 4. Metodo di collegamento dei cavi elettrici dell’unità interna Allentare il coperchio della scatola dei cavi e collegare appropriatamente il cavo elettrico ed il cavo di comunicazione al blocco terminali. Nota: Quando si collega il terminale d’alimentazione al terminale d’alimentazione, prestare attenzione a quanto segue: • ����������������������������������������������������������������������������������������������������������������������������������cherà la generazione di calore. • ������������������������������������������������������������������������������������������������������������������������������������metterà la protezione. • �����������������������������������������������������������������������������������������������������������������������������������ni all’unità collegata. 5. Esempio di diagramma di collegamento dei cavi Per il diagramma di collegamento dei cavi fare riferimento a 5U34HS1 ERA Collocare i cavi in modo che non ci siano pressioni sul coperchio o altre parti della struttura. Fissare i cavi in sicurezza usando le 4 viti incluse, come mostrato nella figura. Fissare in sicurezza, assicurandosi che sui terminali non sia esercitata pressione esterna. 13 Usare i cavi specificati e collegarlisicurezza. Test • Prima di avviare il test, accertarsi di avere portato a termine correttamente i seguenti lavori. 1) Tubature; 2) Collegamento dei cavi elettrici; 3) Corrispondenza corretta dell’unità interna ed esterna; 4) Rabbocco appropriato del refrigerante, se necessario. • Assicurarsi che tutte le valvole d’arresto siano completamente aperte. • Verificare che la tensione fornita all’unità esterna ed alle unità interne sia di 230V. • Controllo errori di collegamento dei cavi Questo prodotto è capace di controllare automaticamente se ci sono errori nei collegamenti dei cavi. Accendere tutti i 4 interruttori DIP della PCB dell’unità esterna come mostrato sulla destra. Poi spegnere l’ unità e riaccenderla; il sistema accederà alla modalità di "Controllo errori di collegamento". Dopo 3 minuti di standby, l’unità avvia il controllo automatico degli errori di collegamento dei cavi. Circa 30 – 50 minuti dopo l’avvio dell’unità (il tempo dipende da quante unità sono installate sul sistema), i LED (da 1 a 5) indicheranno gli errori di collegamento dei cavi. Durante questa procedura, il display mostrerà alternatamene con numeri la frequenza operativa del compressore (e.g. 50 sta per la freuenza operativa corrente) e la dicitura "CH" (che sta per “checking”, controllo). Al termine di questa procedura, se il collegamento dei cavi è corretto, il display mostrerà "0", se invece ci sono errori, il display mostrerà la dicitura "EC" (Errore Collegamento) che lampeggerà. I LED del display indicano gli errori di collegamento, come mostrato nella tabella che segue. Fare riferimento al Manuale di servizio per i dettagli su come leggere i LED. Se non è possibile eseguire il controllo automatico, verificare come di consueto il collegamento dei cavi dell’unità interna ed esterna. LED 1 2 3 4 OFF (Spegnimento) Tutti lampeggianti Tutti accesi Stato ON Lampeggiante Lampeggiante ON ON Lampeggiante Lampeggiante ON Solo un LED lampeggiante 5 Messaggio Unità non collegata Controllo automatico impossibile, tutte le unità cono collegate in modo scorretto Tutte le unità sono collegate in modo corretto Acceso: unità collegata correttamente Lampeggiante: Unità non collegata correttamenLampeggiante te, è necessario modificare manualmente il collegamento dei cavi tra 2, 3, e 5 Acceso: unità collegata correttamente Lampeggiante: Unità non collegata correttamenON te, è necessario modificare manualmente il collegamento dei cavi tra 2 e 3 Anomalia • Test in corso. 1) Quando la temperatura è inferiore ai 16° C, è impossibile eseguire il test di raffreddamento; quando la temperatura è superiore ai 30° C, è impossibile eseguire il test di riscaldamento. 2) Per controllare il raffreddamento, impostare la temperatura minima a 16° C. Per controllare il riscaldamento, impostare la temperatura massima a 30° C. 3) Controllare individualmente la funzione sia di raffreddamento, sia di riscaldamento di ciascuna unità e controllare anche il funzionamento simultaneo di tutte le unità interne. 4) Dopo che l’unità è in funzione da circa 20 minuti, controllare la temperatura emessa dall’unità interna. 5) Dopo avere arrestato l’unità, o dopo avere cambiato la modalità, l’unità non si riavvia per circa 3 minuti. 6) Durante il raffreddamento si può formare della brina sull’unità interna o sui tubi, questo è un fenomeno normale. 7) Usare l’unità osservando le istruzioni del Manuale d’uso. Spiegare accuratamente al cliente come funziona e come si usa il condizionatore in base alle istruzioni del manuale d'uso. • Display numerico a sette cifre 1) Quando l’unità è in funzione, questo display numerico a sette cifre mostrerà la frequenza del compressore. Ad esempio: " " significa che la frequenza del compressore è 40 Hz, " " significa che la frequenza del compressore è 108Hz. 2) Quando c’è un guasto, il display numerico a sette cifre lampeggerà e visualizzerà dei numeri; questi numeri sono il codice di errore. Ad esempio: " " lampeggiante significa errore numero 32, cioè errore di comunicazione tra unità interna ed esterna. • LED comunicazione 5 LED verdi indicano 5 unità interne. Se un LED si accende, significa che la corrispondente unità interna ha una buona comunicazione con l’unità esterna. Se un LED non si accende, significa che non c’è comunicazione tra unità interna ed esterna. 14 Risoluzione dei problemi Motivi possibili LED esterno mostra Controllore Cassette e convertibile interno a cavo mostra il codice di errore esterno mostra utilizza il cronometro e lampada all'esecuzione Lampada Cronometro lampada tempo all'esecuzione di flash tempo di flash Guasto dell'unità esterna EEPROM 1 15 2 IPM sovracorrente o cortocircuito 2 16 2 1 2 Errore di comunicazione tra Modulo e ECU I cavi di comunicazione rotto o non ben collegato. Modulo operato sovraccarico 4 18 2 4 5 19 2 5 Modulo di tensione continua a bassa o alta (sotto 192V o superiore 375V) 6 1A 2 6 Scarico surriscaldamento temperatura. Mancanza di refrigerante, temperatura ambiente troppo alta o PMV bloccato. Malfunzionamento del ventilatore motore a DC 8 1C 2 8 9 1D 2 9 Malfunzionamento del sensore di temperatura di sbrinamento. 10 1E 3 0 Malfunzionamento del sensore di temperatura di aspirazione del compressore 11 1F 3 1 Malfunzionamento del sensore di temperatura ambiente 12 20 3 2 Malfunzionamento del sensore di temperatura di scarico del compressore 13 21 3 3 Errore di comunicazione tra unità interna ed esterna 15 23 3 5 Mancanza di freon 16 36 3 6 Valvola a 4 vie fallimento di commutazione 17 25 3 7 Modulo di sovracorrente / Modulo interruttore guasto 18 26 3 8 sovraccarico interno 20 28 4 0 Smerigliato interno 21 29 4 1 Modulo di temperatura troppo elevata (Protettore a sovraccarico) 23 2B 4 3 Compressore sovracorrente 24 2C 4 4 Ingresso sovracorrente 25 2D 4 5 MCU ripristino 26 2E 4 6 Modulo circuito di corrente rilevamento malfunzionamento 27 2F 4 7 Malfunzionamento del sensore di temperatura del liquido del tubo per l'unità A interna Malfunzionamento del sensore di temperatura del liquido del tubo per l'unità B interna Malfunzionamento del sensore di temperatura del liquido del tubo per l'unità C interna Malfunzionamento del sensore di temperatura del liquido del tubo per l'unità D interna Malfunzionamento del sensore di temperatura del gas del tubo per l'unità A interna Malfunzionamento del sensore di temperatura del gas del tubo per l'unità B interna Malfunzionamento del sensore di temperatura del gas del tubo per l'unità C interna Malfunzionamento del sensore di temperatura del gas del tubo per l'unità D interna Malfunzionamento del sensore di temperatura del gas del tubo per l'unità E interna Malfunzionamento del sensore di temperatura modulo 28 30 4 8 29 31 4 9 30 32 5 0 31 33 5 1 32 34 5 2 33 35 5 3 34 36 5 4 35 37 5 5 36 38 5 6 38 3A 5 8 Malfunzionamento del sensore di temperatura di condensazione 39 3B 5 9 Malfunzionamento del sensore di temperatura del liquido tubo per unità E interna Malfunzionamento del sensore di temperatura tubazione 40 3C 6 0 41 3D 6 1 Il sistema di pressione alta spento 42 3E 6 2 Il sistema di pressione bassa spento 43 3F 6 3 Protezione del sistema alla pressione alta. Sovrabbondanza refrigerante, temperatura di condensazione elevata. O malfunzionamento del motore del ventilatore. 44 40 6 4 Protezione del sistema alla pressione bassa. 45 Carenza di refrigerante, temperatura sbrinamento basso, O malfunzionamento del motore del ventilatore. 41 6 5 Malfunzionamento del sensore di temperatura modulo 42 6 6 46 15 Indirizzo: No. 1 Haier Road, Hi-tech Zone. Qingdao 266101 Repubblica Popolare Cinese Contatti: TEL +86-532-8893-6943; FAX +86-532-8893-6999 Sito Internet: www.haier.com MANUEL D'UTILISATION DU CLIMATISEUR À PLUSIEURS BLOCS Consignes de sécurité------------------------ 3 Accessoires------------------------------------- 4 Précautions pour le choix de l' Emplacement----------------------------------- 4 Plans d’installation pour les unités intérieures et extérieures-------------------- 5 Précautions relatives à l'installation------- 7 Guide d'installation de l'unité extérieure 7 Limites relatives à l'installation------------- 7 Travaux liés au tuyau du réfrigérant------ 7 Fonctionnement de l'aspiration------------12 Câblage-----------------------------------------12 Essai de fonctionnement-------------------14 Dépannage-------------------------------------15  Veuillez lire ce manuel attentivement avant d'installer l'appareil. Conservez ce manuel d’utilisation pour toute référence ultérieure. Français Table des matières Haier Industrial Park, No.1 Haier Road, Qingdao, RR. Chine CONFORMITÉ DES MODÈLES À LA LÉGISLATION EUROPÉENNE CE Tous les appareils sont conformes aux directives Européennes suivantes : - Directive basse tension 73/23/CEE - Directive basse tension 2006/95/CE - Compatibilité électro-magnétique 89/336/CEE - Compatibilité électro-magnétique 2004/108/CE ROHS Les appareils répondent aux exigences de la directive 2002/95/ CEE du parlement européen et du conseil sur la limitation des substances dangereuses dans les Équipements Électriques et Électroniques (Directive UE RoHS). DEEE Conformément à la Directive 2002/96/CE du Parlement Européen, nous informons ici-même le consommateur des conditions d'élimination des appareils électriques et électroniques. CONDITIONS D'ÉLIMINATION Votre climatiseur porte ce symbole. Ceci signifie que les produits électriques et électroniques ne doivent pas être mis au rebut avec les déchets domestiques non triés. Ne pas tenter de démonter le système par soi-même : le démontage du système de climatisation, le traitement du liquide réfrigérant, de l'huile et d'autres pièces doivent être effectués par un installateur qualifié conformément à la législation locale et nationale. Les climatiseurs doivent être traités dans des installations spécialisées pour réutilisation, recyclage et récupération. S'assurer que le produit est éliminé de façon correcte permet d'aider à éviter des conséquences potentielles négatives sur l'environnement et la santé humaine. Merci de contacter l'installateur ou les autorités locales pour plus d'information. Les piles doivent être enlevées de la télécommande et faire l'objet d'une élimination séparée conformément à la législation locale et nationale. INFORMATIONS IMPORTANTES CONCERNANT LE LIQUIDE RÉFRIGÉRANT UTILISÉ Contient des gaz à effet de serre fluorés couverts par le protocole de Kyoto. Kg Kg Kg Cet appareil contient des gaz à effet de serre fluorés couverts par le protocole de Kyoto. Ne pas ventiler à l'air. Type de réfrigérant : R410A Valeur de GWP*: 1975 GWP = global warming potential - potentiel de réchauffement de la planète. Merci de remplir à l'encre indélébile; •1 La charge de réfrigérant usine de l'appareil •2 la quantité supplémentaire de réfrigérant chargée sur place et • 1+2 charge totale de réfrigérant sur l’étiquette de charge de réfrigérant fournie avec le produit. L'étiquette renseignée doit être collée à proximité du port de chargement de l'appareil (par ex.sur l'intérieur du couvercle de valeur d'arrêt). A contient des gaz à effet de serre fluorés couverts par le protocole de Kyoto. B charge de réfrigérant usine de l'appareil : voir sur la plaque signalétique de l'unité C quantité supplémentaire de liquide réfrigérant chargée sur place D Charge totale de réfrigérant E Unité extérieure F cylindre réfrigérant et orifice d'admission de chargement Consignes de sécurité • Veuillez lire attentivement ces consignes de sécurité pour garantir la bonne installation de l'appareil. • Ce manuel classe les consignes sous AVERTISSEMENT et MISE EN GARDE. • Assurez-vous de suivre toutes les précautions ci-dessous : elles sont toutes importante pour garantir la sécurité. AVERTISSEMENT Ne pas suivre l'un des AVERTISSEMENTS peut entraîner de graves conséquences, comme la mort ou une blessure grave. MISE EN GARDE Ne pas suivre une des MISES EN GARDE peut entraîner dans certain cas de graves conséquences. • Les symboles de sécurité suivants, sont utilisés dans ce manuel : Assurez-vous de vous conformer à cette instruction. Assurez-vous d'avoir établi une connexion à la terre. Ne jamais. • Une fois l'installation effectuée, testez l'unité pour éliminer toute erreur liée à l'installation. Transmettez à l'utilisateur toutes les instructions adéquates, concernant l'utilisation et le nettoyage de l'unité conformément au manuel d'utilisation. AVERTISSEMENT • L'installation doit être effectuée par le fournisseur ou tout autre professionnel. Une mauvaise installation peut entraîner des fuites d'eau, une électrocution, ou un incendie. • Installez le climatiseur conformément aux instructions indiquées dans ce manuel. Une installation incomplète peut entraîner des fuites d'eau, une électrocution, ou un incendie. • Assurez-vous d'utiliser les pièces d'installation fournies ou spécifiées. L'utilisation d'autres pièces peut entraîner l'instabilité de l'appareil, des fuites d'eau, une électrocution, ou un incendie. • Installez le climatiseur sur une base solide capable de supporter le poids de l'unité. Une base inadéquate ou une installation incomplète peut entraîner des blessures en cas de chute de l'unité de sa base. • Les travaux électriques doivent être effectués conformément au manuel d'installation et aux réglementations nationales relatives aux câblages, ou au code de déontologie. Une capacité insuffisante ou des travaux électriques incomplets peuvent entraîner une électrocution ou un incendie. • Assurez-vous d'utiliser un circuit d'alimentation dédié. N'utilisez jamais une source d'alimentation partagée avec un autre appareil. • Pour le câblage, utilisez un câble suffisamment long pour parcourir la distance totale sans connexion intermédiaire. N'utilisez pas de rallonge. Ne placez pas d'autres charges sur l'alimentation électrique. Utilisez un circuit d'alimentation dédié. (Ne pas respecter cette consigne peut entraîner une chaleur anormale, une électrocution ou un incendie.) • Utilisez les types de câbles spécifiés pour les connexions électriques entre les unités intérieure et extérieure. Protégez les fils d'interconnexion avec des manchons pour que leurs borniers ne subissent aucune contrainte externe. Des connexions ou des mises sous manchon incomplètes peuvent entraîner la surchauffe des borniers ou un incendie. • Après avoir effectué la connexion, les interconnexions et le câblage d'alimentation, assurez-vous de placer les câbles de façon à ce qu'ils ne reposent pas en force sur les couvercles ou les panneaux électriques. Installez les couvercles sur les câbles. Une installation incomplète des couvercles peut entraîner une surchauffe des borniers, une électrocution, ou un incendie. • En cas de fuite du liquide réfrigérant pendant l'installation, ventilez la pièce. (Le liquide réfrigérant produit un gaz toxique s'il est exposé à des flammes.) • Une fois l'installation effectuée, contrôlez l'absence de fuite de liquide réfrigérant. (Le liquide réfrigérant produit un gaz toxique s'il est exposé à des flammes.) • Lorsque vous installez ou déplacez le système, assurez-vous de garder le circuit réfrigérant exempt de toute autre substance que le réfrigérant spécifié (R410A), comme de l'air. (Toute présence d'air ou d'autre substance étrangère dans le circuit réfrigérant peut provoquer une augmentation anormale de la pression ou une rupture, entraînant des blessures.) • Pendant l'aspiration, stoppez le compresseur avant de déposer le tuyau du réfrigérant. Si le compresseur fonctionne encore et que la soupape d'arrêt est ouverte pendant l'aspiration, l'air sera aspiré dans l'appareil provoquant une pression anormale dans le cycle du congélateur et entraînant sa rupture et même des blessures. • Assurez-vous d'avoir établi une connexion à la terre. Ne branchez pas l'appareil à la terre en utilisant une canalisation, un fil de mise à la terre de parafoudre, ou la terre d'une ligne téléphonique. Une mise à la terre incomplète peut entraîner une électrocution ou un incendie. Une surtension importante provoquée par la foudre ou une autre source, peut entraîner des dommages au climatiseur. • Assurez-vous d'installer un disjoncteur de fuite à la masse. Ne pas installer de disjoncteur de fuite à la masse peut entraîner une électrocution ou un incendie. MISE EN GARDE • N'installez pas le climatiseur dans un endroit où il peut être exposé à une fuite de gaz inflammable. En cas de fuite de gaz et d'accumulation autour de l'unité, risque d'incendie. • Procédez à l'installation des tubulures de vidange conformément aux instructions de ce manuel. Une mise en place inadéquate des tubulures peut entraîner une inondation. • Serrez l'écrou d'évasement selon la méthode spécifiée, avec entre autre une clé dynamométrique. Si l'écrou d'évasement est trop serré, il est susceptible de se fissurer après un certain temps et entraîner la fuite du liquide réfrigérant. • Assurez-vous de prendre les mesures adéquate pour éviter que l'unité extérieur ne puisse être utilisée comme abris pour les petits animaux. Les petits animaux peuvent entrer en contact avec les pièces électriques entraînant des dysfonctionnements de l'appareil, une émission de fumée ou un incendie. La zone autour de l'unité doit rester propre ; veuillez en informer le client.  Accessoires Accessoires fournis avec l'unité extérieure : N° Plan Nom des pièces Quantité Remarque 1 1 Coude de vidange 2 Caoutchouc amortisseur 3 4 1 3 Coiffe 3 4 Adaptateur(3/8 1/2) 1 5 Adaptateur(1/2 3/8) 1 Précautions pour le choix de l'Emplacement 1) Choisissez un emplacement suffisamment solide pour supporter le poids et les vibrations de l'unité, un endroit où le bruit de fonctionnement de l'unité ne sera pas amplifié. 2) Choisissez un endroit où l'air chaud libéré par l'unité ni le bruit de fonctionnement ne causeront de nuisance à l'entourage de l'utilisateur. 3) Évitez les endroits à proximité d'une chambre à coucher par exemple. Le bruit de fonctionnement ne doit gêner personne. 4) L'espace doit être suffisant pour porter l'unité à l'intérieur du site et pouvoir la ressortir. 5) L'espace doit être suffisant pour le passage de l'air. Aucune obstruction ne doit se trouver autour de l'entrée et de la sortie d'air. 6) Le site et ses alentours doivent être exempts de tout risque de fuite de gaz inflammable. Placez l'unité de façon à ce que le bruit et l'air chaud libéré ne dérangent aucun voisin. 7) Installez les unités, les cordons d'alimentation et les câbles entre les unités à au moins 3 mètres de distance d'un poste de télévision ou de radio. Ceci évitera toute interférence au niveau des images et du son. (Les bruits peuvent s'entendre même si l'unité est distante de plus de 3 mètres, selon les conditions des ondes radio.) 8) Près des côtes et dans d'autres endroits présentant une atmosphère salée de gaz sulfaté, la corrosion peut réduire la durée de vie du climatiseur. 9) L'eau de vidange coule hors de l'unité extérieure. Ne placez rien de sensible à l'humidité sous l'unité. REMARQUE : Ne pas suspendre au plafond, ne pas empiler les appareils. MISE EN GARDE  Lorsque le climatiseur fonctionne alors que la température ambiante extérieure est basse, assurez-vous de suivre les instructions ci-dessous. 1) Pour éviter de l'exposer au vent, installez le côté aspiration de l'unité extérieure vers le mur. 2) N'installez jamais l'unité extérieure avec son côté aspiration exposé directement au vent. 3) Pour éviter tout exposition au vent, il est recommandé d'installer une chicane du côté rejet d'air de l'unité extérieure. 4) En cas d'installation dans une région à fortes chutes de neige, choisissez un endroit où la neige n'affecte pas l'unité. • Construction d'un grand écran de protection. • Construction d'un support. Installez l'unité à une hauteur suffisante par rapport au sol, pour éviter que l'appareil ne soit recouvert de neige. Plans d'installations pour les unités intérieures et extérieures 1. Ne connectez pas le conduit de jonction intégré et l'unité extérieure au moment d'effectuer les travaux liés aux tuyaux, avant de connecter l'unité intérieure, s'il s'agit d'ajouter ultérieurement une autre unité intérieure. Assurez-vous qu'aucune saleté ni humidité ne pénètre par l'une des deux extrémités du conduit de jonction intégré. 2. Il est impossible de connecter l'unité intérieur pour une seule pièce. plu sd e 10 plus de 5 cm Figure d'installation veuillez vous référer au 4U30HS1ERA cm Disposition des directions de la tuyauterie Arrière gauche Gauche Arrière droite Droite En bas Il faut faire particulièrement attention au soulèvement du tuyau de vidange. Enveloppez le tuyau d'isolation de bas en haut avec le ruban de finition. Coupez le tuyau d'isolation thermique à la longueur appropriée et enveloppez-le de ruban adhésif. Assurez-vous qu'aucun espace n'est laissé au niveau de la ligne de coupe du tuyau d'isolation. m e 10 c plus d plus de 10 c m s plu m 0c e6 d s plu 5c 2 de m  En cas de risque de chute ou de basculement de l'unité, fixez l'unité avec des boulons de fondation, un câble ou par tout autre moyen. Si l'emplacement ne dispose pas de système de drainage adéquat, placez l'unité sur un socle de montage horizontal (ou un pied en plastique). Installez l'unité extérieure à l'horizontale. Ne pas respecter l'installation horizontale peut entraîner des fuites d'eau ou une accumulation. Plans d’installation pour les unités intérieures et extérieures Avertissements relatives aux connexions modèle priorité au niveau de la connexion de l’ unité intérieure et des soupapes d’arrêt les plus hautes, du bas vers le haut  Lorsqu’il y a 1 unité C D E intérieure, la soupape d’ arrêt prioritaire est Lorsqu’il y 2 unités CB DC ED intérieures, les soupapes d’arrêt prioritaires sont Lorsqu’il y 3 unités CBA DCB EDC intérieures, les soupapes d’arrêt prioritaires sont Lorsqu’il y a 4 unités DCBA EDCB intérieures, les soupapes d’arrêt prioritaires sont Lorsqu’il y a 5 unités EDCBA intérieures, les soupapes d’arrêt prioritaires sont Remarque : pour un meilleur retour d’huile et un système plus fiable, suivez les consignes ci-dessus pour connecter l’unité intérieure. Précautions relatives à l'installation • Vérifiez la résistance et l'horizontalité du lieu d'installation, de façon à ce que le fonctionnement de l'unité ne génère pas de vibration ou de bruit une fois l'unité installée. • Fixez l'unité de façon sûre avec les boulons de fondation, conformément au plan des fondations. (Préparez quatre jeux de boulons de fondation M8 ou M10, des écrous et des rondelles, le tout disponibles en magasin.) • Il est conseillé de visser les boulons de fondation en les enfonçant de 20 mm par rapport à la surface de la fondation. Guide d'installation de l'unité extérieure • Si un mur ou tout autre obstacle se trouve sur le chemin du flux d'air d'entrée ou de sortie de l'unité extérieure, suivez les directives d'installation ci-dessous. • Si vous utilisez l'un des plans d'installation suivant, la hauteur du mur côté sortie, doit être inférieure à 1 200 mm. Mur d'un côté Plus de 300 Plus de 50 1200 ou moins Vue latérale Mur des trois côtés Mur des deux côtés Plus de 150 Plus de Plus de 300 100 Plus de 100 Vue latérale Plus de 300 Plus de 50 Plus de 50 Vue latérale Limites relatives à l'installation 1. Précautions relatives à l'installation • Vérifiez la résistance et l'horizontalité du lieu d'installation, de façon à ce que le fonctionnement de l'unité ne génère pas de vibration ou de bruit une fois l'unité installée. • Fixez l'unité de façon sûre avec les boulons de fondation, conformément au plan des fondations. • Il est conseillé de visser les boulons de fondation en les enfonçant de 20 mm par rapport à la surface de la fondation. 2. Choix d'un emplacement d'installation pour les unités extérieures • La longueur maximale autorisée du tuyau réfrigérant et la différence de hauteur maximale autorisée entre les unités extérieure et intérieure, sont indiquées ci-dessous. (Plus le tuyau réfrigérant est court, meilleures sont les performances. Effectuez les connexion de façon à ce que le tuyau soit le plus court possible. La longueur la plus courte autorisée par pièce est de 3 m.) Classe de capacité de l'unité extérieure Longueur des tuyaux vers chaque unité intérieure  Longueur totale du tuyau entre toutes les unités Limites relatives à l'installation Unité intérieure Différence de niveau : 15m max. Différence de niveau : 7,5m max. Unité extérieure Différence de niveau : 15m max. Différence de niveau : 7,5m max. Unité extérieure Unité intérieure Si l'unité extérieure est positionnée à un niveau plus élevé que les unités intérieures. (Si elle est positionnée à un niveau plus bas qu'une ou plusieurs unités intérieures.) Si l'unité extérieure est positionnée à un niveau plus élevé que les unités intérieures. Unité intérieure Différence Différence de niveau : de niveau : 15m max. 7,5m max. Unité extérieure Si l'unité intérieure est positionnée à un niveau plus élevé que les unités extérieures. Travaux liés au tuyau du réfrigérant 1. Installation de l'unité extérieure 1) Pour installer l'unité extérieure, veuillez vous référer aux sections "Précautions pour le choix de l'emplacement" et "Schémas d'installation des unités intérieures et extérieures". 2) Si des travaux de drainage sont nécessaires, suivez la procédure ci-dessous. 2. Travaux de drainage 1) Utilisez le bouchon de vidange. 2) Si l'orifice de vidange est recouvert par un socle de montage ou par la surface du sol, placez des pieds supplémentaires d'une hauteur minimale de 30 mm sous les pieds de l'unité extérieure. 3) Dans les régions froides, n'utilisez pas de tuyau de vidange pour l'unité extérieure. (L'eau de vidange risque en effet de geler et de gêner les performances de chauffage.) Tuyau Tuyau Coude de vidange  Coude de vidange Travaux liés au tuyau du réfrigérant 3. Travaux liés au tuyau du réfrigérant 1) Alignez les centres des deux évasements et serrez à la mains les écrous d'évasement de 3 ou 4 tours. Puis serrez-les complètement avec une clé dynamométrique. Utilisez les clés dynamométriques pour serrer les écrous d'évasement et éviter ainsi tout dommage au niveau des écrous ainsi que les fuites de gaz. Couple de serrage des écrous d'évasement Écrou d'évasement pour 6,35 14,2-17,2 N.m (144-175 kgf.cm) Écrou d'évasement pour 9,52 32,7-39,9 N.m (333^07kgf.cm) Écrou d'évasement pour 12,7 49,5-60,3N.m (505-615 kgf.cm) Écrou d'évasement pour 15,88 61,8-75,4N.m (630-769 kgf.cm) Couple de serrage du capuchon de valve Tuyau de liquide 26,5-32,3 N.m (270-330 kgf.cm) Tuyau de gaz 48,1-59,7N.m (490-610 kgf.cm) Appliquez ici de l'huile incongelable Clé dynamométrique Clé Joint de tuyau Écrou en cône Couple de serrage du capuchon de l'orifice d'entretien 10,8-14,7N.m (110-150 kgf.cm) 2) Pour éviter toute fuite de gaz, appliquez de l'huile incongelable sur les surfaces intérieure et extérieure de l'évasement. (Utilisez l'huile incongelable pour R410A) 4. Purger l'air et contrôler l'absence de fuite de gaz Lorsque les travaux de tuyauterie sont terminés, il est indispensable de purger l'air et de contrôler l'absence de fuite de gaz. AVERTISSEMENT 1) Ne mélangez aucune autre substance que le réfrigérant spécifié (R41 OA) dans le cycle de réfrigération. 2) En cas de fuite de gaz réfrigérant, ventilez la pièce aussi rapidement et autant que possible. 3) Le R410A, tout comme d'autres réfrigérants, doit toujours être récupéré. Il ne doit pas être jeté directement dans la nature. 4) Utilisez la pompe à vide destinée exclusivement pour le R41 OA. L'utilisation de la même pompe à vide pour différents réfrigérants peut endommager la pompe ou l'unité. • Avant d'ajouter du réfrigérant, purgez l'air des tuyaux de réfrigération et de l'unité intérieure avec une pompe à vide, puis chargez le réfrigérant supplémentaire. • Utilisez une clé hexagonale (4mm) pour manipuler la tige de manoeuvre de la soupape d'arrêt. • Tous les joints des tuyaux de réfrigérant doivent être serrés en utilisant une clé dynamométrique et en appliquant le couple de serrage spécifié. Branchez le côté projection du tuyau de charge (qui vient du collecteur de jauge) à l'orifice d'entretien de la soupape d'arrêt du gaz. Ouvrez complètement la valve basse pression du collecteur de jauge (Lo) et fermez complètement sa valve haute pression (Hi). (La valve haute pression n'a habituellement pas besoin d'être manipulée.) Procédez au pompage à vide. Contrôlez le manomètre du composé, il doit indiquer -0,1 MPa (-76 cmHg). Une évacuation d'au moins 1 heure est recommandée. Fermez la valve basse pression du collecteur de jauge (Lo) et stoppez la pompe à vide. (Patientez 4 à 5 minutes et assurez-vous que le l'aiguille du dispositif de mesure de couplage ne retourne pas en arrière. Si elle retourne en arrière, cela indique la présence d'humidité ou une fuite au niveau des pièces de jonction. Après avoir inspecté toutes les connexions, avoir desserré puis resserré les écrous, reprenez les étapes 2 à 4.) Retirez les couvercles de la soupape d'arrêt liquide et de la soupape d'arrêt gaz. Ouvrez la soupape en tournant la tige de manoeuvre de la soupape d'arrêt liquide de 90 degrés vers la gauche avec une clé hexagonale. Refermez la soupape après 5 secondes, et contrôlez l'absence de fuites de gaz. Utilisez de l'eau savonneuse et contrôlez l'absence de fuite de gaz au niveau de l'évasement de l'unité intérieure, de l'évasement de l'unité extérieure, et des tiges de manoeuvre des soupapes. Une fois les vérifications terminées, essuyez l'eau savonneuse. Déconnectez le tuyau de charge de l'orifice d'entretien de la soupape d'arrêt gaz, puis ouvrez complètement les soupapes d'arrêt gaz et liquide. (N'essayez pas de tournez les tiges de manoeuvre des soupapes au-delà de leurs butées d'arrêt).  Serrez les capuchons des soupapes et de l'orifice d'entretien des soupapes d'arrêt liquide et gaz avec une clé dynamométrique, en appliquant les couples spécifiés. Voir la section "3 Tuyau du réfrigérant" à la page 6 pour plus de détails. Travaux liés au tuyau du réfrigérant 5. Remplissage de liquide réfrigérant Vérifiez le type de réfrigérant à utiliser sur la plaque signalétique du climatiseur. Précautions lors de l'ajout du R410A Effectuez le remplissage par du réfrigérant liquide depuis le tuyau de liquide. S'il s'agit d'un réfrigérant mixte, l'ajout sous forme de gaz peut entraîner la modification de la composition du réfrigérant, gênant ainsi le fonctionnement normal de l'appareil. 1) Avant le remplissage, vérifiez si le cylindre dispose d'un siphon relié ou non. (Le climatiseur doit alors porter une mention "siphon de remplissage liquide relié"). 2) Assurez-vous d'utiliser les outils R41 OA de façon à garantir la pression et d'éviter l'introduction d'objets étrangers. Remplissage des autres cylindres Remplissage d'un cylindre avec le siphon relié Maintenez le cylindre à la verticale pendant le remplissage. Tournez le cylindre à l'envers pour le remplir. Le siphon contient un tuyau. Il ne faut donc pas le mettre à l'envers pour le remplir de liquide. 6. Chargement du réfrigérant 1) Ce système doit utiliser le réfrigérant R410A. 2) Ajoutez 20g de réfrigérant par mètre lorsque la longueur totale du tuyau dépasse la valeur standard. Assurez-vous cependant que la longueur totale du tuyau de liquide est inférieure à la valeur maximale. Unité extérieure Longueur standard to- Longueur maximale to tale du tuyau de liquide tale du tuyau de liquide Remarques : 1) Lorsque vous utilisez ce produit, il est inutile de définir l'adresse. Les fils UN entre les unités intérieure et extérieure doivent correspondre. Si ce n'est pas le cas, la communication va échouer. 2) Paramétrage du fonctionnement silencieux. Réglez le DIP "8" sur la position ON du SW5. Le système va fonctionner en émettant moins de bruit, mais la capacité maximale va également être légèrement réduite. Ne modifiez pas les paramétrage des autres interrupteurs. Un mauvais réglage peut endommager le système ou entraîner d'autres dysfonctionnements. 7. Précautions relatives à la mise en place du tuyau réfrigérant • Mise en garde relative à la manipulation du tuyau 1) Protégez l'extrémité ouverte du tuyau contre la poussière et l'humidité. 2) Tous les cintrages de tuyaux doivent être effectués avec précaution. Utilisez une cintreuse pour cintrer les tuyaux. (Le rayon de cintrage doit être compris entre 30 et 40 mm, ou supérieur.) • Choix du cuivre et matériaux d'isolation thermique Lorsque vous utilisez des tuyaux et des raccords en cuivre du commerce, respectez les consignes suivantes : 1) Matériau d'isolation : Mousse en polyéthylène Coefficient de conductibilité calorifique : de 0,041 à 0,052 W/mK (de 0,035 à 0,045 kcal/mh°C) La température maximale de la surface du tuyau de gaz réfrigérant est de 110°C. Choisissez des matériaux d'isolation thermique capables de supporter cette température. 2) Assurez-vous d'isoler le tuyau de liquide et le tuyau de gaz. Choisissez des dimensions d'isolation selon les indications suivantes. Tuyau de gaz Diamètre extérieur : 9,52 mm,12,7 mm Épaisseur : 0,8 mm Tuyau de liquide Diamètre extérieur : 6,35 mm Épaisseur : 0,8 mm 10 Isolation du tuyau de gaz Diamètre intérieur : 12-15 mm, 12,7 mm Épaisseur : 13mm min. Isolation du tuyau de liquide Diamètre intérieur : 18-10 mm Épaisseur : 10 mm min. Travaux liés au tuyau du réfrigérant 3) Utilisez des tuyaux d'isolation thermique distincts pour le tuyau de réfrigérant liquide et le tuyau de réfrigérant gaz. Mur Câblage dans l'unité Tuyau de gaz Tuyau de liquide Assurez-vous de placer un capuchon. Pluie Si aucun capuchon n'est disponible, couvrez l'ouverture de l'évasement avec un ruban pour empêcher la saleté ou l'eau d'y pénétrer. Isolation du tuyau de liquide Isolation du tuyau de gaz Ruban de finition Tuyau de vidange Contrôle La surface intérieure de l'évasement ne doit présenter aucun défaut. L'extrémité du tuyau doit être évasé de façon régulière et dessiner un cercle parfait. Assurez-vous que l'écrou d'évasement est bien installé. Coupez exactement à angle droit. Nettoyez les bavures Positionnez exactement comme indiqué ci-dessous. Matrice de l'outillage d'évasement Outil d'évasement pour Outil d'évasement classique R410A Type à embrayage Type à écrou à oreilles Type à embrayage (rigide) (Imperial) 0-0,5mm 1,0-1,5mm 1,5-2,0mm 8. Travail de coupe et d'évasement de la tuyauterie • La coupe du tuyau doit être effectuée avec un coupe-tuyau. Vous devez nettoyer les bavures. • Après avoir inséré l'écrou évasé, vous pouvez procéder au travail d'évasement. Correct Diamètre du tuyau Côté liquide 6,35mm (1/4”) Matrice de l'outillage 9,52mm (3/8”) Côté gaz d'évasement 12,7mm (1/2”) Tuyau Incorrect Taille A (mm) 0.8-1.5 1.0-1.5 1.0-1.5 Insuffi- Evasement endomFissure sant magé Partiel Vers extérieur 9. Vidange • Installez le tuyau de vidange de manière à ce que la pente soit descendante. Ne pas effectuer la vidange comme illustré ci-dessous. Moins de 5 cm Il est surélevé à mi-chemin. L'extrémité est immergée dans l'eau L'intervalle avec le sol est trop petit. Il ondule. Il y a une odeur nauséabonde de la fosse. • Versez de l'eau dans le bac de vidange de l'unité intérieure et vérifiez qu'il soit dirigé vers l'extérieur. • Si le tuyau de vidange est dans une pièce, utilisez une isolation thermique. AVERTISSEMENT 1) 2) 3) 4) 5) 6) N'utilisez pas d'huile minérale sur les pièces évasées. Empêchez que l'huile minérale ne pénètre dans le système, cela réduirait la durée de vie des unités. N'utilisez pas de tuyaux ayant déjà été utilisés dans d'autres installation. N'utilisez que les pièces fournies avec l'unité. Pour garantir sa durée de vie, n'installez jamais de déshydrateur sur cette unité R41 OA Le matériau déshydrateur peut se dissoudre et endommager le système. Un évasement insuffisant peut entraîner la fuite du gaz réfrigérant. 11 Fonctionnement de l'aspiration Pour protéger l'environnement, assurez-vous d'effectuer un pompage en cas de déplacement de l'unité ou lorsque vous la mettez au rebut. 1) Retirez les couvercles de la soupape d'arrêt liquide et de la soupape Soupape d'arrêt liquide d'arrêt gaz. Clé hexago2) Procédez à un refroidissement forcé. nale 3) Après cinq à dix minutes, fermez la soupape d'arrêt liquide avec une clé Fermer dynamométrique. 4) Après deux à trois minutes, fermes la soupape d'arrêt gaz et stoppez le refroidissement forcé. Soupape d'arrêt gaz Capuchon de soupape Câblage 1. Câblage électrique • Le climatiseur doit utiliser un circuit spécial. Son câblage est à effectuer par un électricien qualifié conformément aux réglementations nationales en la matière. • Le câble de mise à la terre et le câble neutre doivent être strictement distincts. Brancher le câble neutre avec le câble de mise à la terre est incorrect. • Installez un disjoncteur de fuite. • Tous les câbles électriques doivent être en cuivre. Alimentation : 1PH, 220-230V-, 50Hz. • La méthode de câblage de la ligne d'alimentation est une connexion en Y. Si la ligne d'alimentation est endommagée, et pour éviter tout risque d'électrocution, il faut la remplacer par le fabricant ou son centre de réparation ou toute autre personne qualifiée. Le câble de branchement doit être blindé. Fusible : T3.15A250VAC T16A250VAC (veuillez consulter le schéma de câblage de l'unité extérieure.) • Veuillez consulter le schéma de circuit pour le remplacement du fusible. 2. Méthode de câblage • Méthode de câblage pour les bornes orbiculaires Pour la connexion des câbles avec des bornes orbiculaires, utilisez la méthode de câblage de la figure de droite : retirez la vis de connexion, placez la vis dans la bague à l'extrémité du câble, puis branchez le câble au bornier. Serrez la vis. Méthode de câble pour les bornes droites. • Pour la connexion des câbles sans bornier orbiculaires, la méthode de câblage est la suivante : desserrez la vis de connexion et insérez l'extrémité du câble de connexion complètement dans le bornier. Serrez ensuite la vis. Tirez légèrement le fil vers l'extérieur pour vérifier s'il est bien maintenu. • Méthode de connexion sertie pour les câbles sans borne Branchez le fil dont le diamètre est identique, des deux côtés de la borne Ne branchez pas le fil dont le diamètre est identique, du même côté. Méthode de câblage pour le bornier à anneau Bon pressage Ne branchez pas le fil dont les diamètres sont différents Mauvais pressage Bornier Pinces de pressage • Méthode de connexion sertie pour câble de connexion Après le branchement. le fil doit être maintenu par un recouvrement. Le recouvrement doit appuyer sur la gaîne de protection du câble de connexion, comme le montre la figure en haut à droite. Remarque : Lors de la connexion du câble, confirmez le numéro de la borne des unités intérieures et extérieures. Un mauvais branchement va endommager la commande du climatiseur, ou empêcher son fonctionnement. 3. Méthode de câblage de l'unité extérieure : • Ligne d'alimentation Retirez le tableau de réparation de l'unité extérieure et desserrez le recouvrement de fils A. Passez ensuite le fil sous tension, le fil neutre et le fil de mise à la terre dans le recouvrement. Branchez-les dans le bornier correspondant. Après la connexion, serrez le recouvrement de fils pour qu'il retrouve sa forme précédente. Câble de communication de l'unité intérieure. • Desserrez le recouvrement de fils. Passez le câble de communication dans le recouvrement de fils B puis branchez-le au bornier correspondant. Après la connexion, serrez le recouvrement de fils B pour qu'il retrouve sa forme précédente. Remarque : le câble de la ligne d'alimentation et le câble de communication sont à fournir par le client. 12 Câblage Recouvrement Bornier de fils C Recouvrement de fils D Recouvrement de fils B Recouvrement de fils E Recouvrement de fils A Recouvrement de fils A Recouvrement de fils C Recouvrement de fils B Bornier Couvercle de soupape Couvercle de soupape –¨ 25.40 0 4. Méthode de câblage de l'unité extérieure Desserrez le recouvrement de fils puis branchez la ligne d'alimentation et le câble de communication de l'unité intérieure au bornier correspondant. Remarque : Lorsque vous brancher la ligne d'alimentation à la borne d'alimentation, prenez garde aux points suivants : • Ne branchez pas une ligne d'alimentation dont les dimensions ne correspondent pas à l'extrémité du câble de connexion. Un mauvais contact entraîne une production de chaleur. • Ne branchez pas une ligne d'alimentation dont les dimensions ne correspondent pas à l'extrémité du câble de mise à la terre. Un mauvais contact affecte la protection. • Ne branchez pas la ligne d'alimentation à l'extrémité de connexion du câble de communication. Une mauvaise connexion va endommager l'unité connectée. 5. Exemple de schéma de câblage. Pour le schéma de câblage, veuillez vous référer au 5U34HS1 ERA Placez les câbles de façon à ce qu'aucune tension ne soit appliquée sur l'orifice d'entretien ou sur d'autres pièces structurelles. Fixez fermement le câblage de la branche en utilisant les 4 vis fournies, comme le montre la figure. En le fixant, assurezvous qu'aucune pression extérieure n'est appliquée sur les bornes. 13 Utilisez les fils spécifiés et branchez-les de façon sûre. Essai de fonctionnement • Avant de commencer l'essai, vérifiez que les travaux suivants ont bien été effectués. 1) Travaux de tuyauterie correctement effectués ; 2) Travaux de câblage correctement effectués ; 3) Bonne correspondance des unités intérieure et extérieure ; 4) Recharge de réfrigérant effectuée, si nécessaire. • Assurez-vous que toutes les soupapes d'arrêt sont bien ouvertes. • Contrôlez la tension fournie aux unités intérieure et extérieure. La tension doit être de 230V. • Contrôle des erreurs de câblage Ce produit est capable de contrôler automatiquement les erreurs de câblage. Allumez les 4 commutateurs DIP du petit tableau PC d'entretien de l'unité extérieure, comme indiqué sur la droite. Puis mettez l'unité sous tension et remettez-la sous tension. Le système exécute le "Contrôle des erreurs de câblage". Après 3 minutes de veille, l'unité lance automatiquement le contrôle du câblage. 30 à 50 minutes (selon le nombre d'unités installé dans le système) après le démarrage de l'unité, les Erreurs de câblage s'affichent en voyants DEL (1 à 5). Pendant cette exécution, le nombre numérique va afficher la fréquence de fonctionnement du compresseur (par exemple 50 indique la fréquence actuelle de fonctionnement) puis les lettres "CH" (pour 'checking' ou contrôle). Une fois le contrôle effectué, si le câblage est correct, le nombre numérique affiche "0". Le nombre numérique affiche "EC" (pour 'error connection' ou erreur de connexion) et clignote en cas d'erreur dans le câblage. Les voyants DEL de l'écran d'entretien indique le type d'erreur de câblage, comme le montre le tableau ci-dessous. Pour plus de détails sur la lecture de l'écran DEL, veuillez vous référer au manuel d'entretien. Si un contrôle automatique n'est pas possible, contrôlez le câblage et la tuyauterie de l'unité intérieure en consultant le manuel d'utilisation. DEL 1 2 3 ARRÊT 4 5 TOUS clignotent TOUS ALLUMÉS Statut ALLUMÉ CLIGNOTE CLIGNOTE ALLUMÉ CLIGNOTE ALLUMÉ CLIGNOTE CLIGNOTE ALLUMÉ ALLUMÉ Un seul voyant DEL clignote Message Unité non connectée Contrôle automatique impossible, toutes les connexions sont incorrectes Toutes les unités sont bien branchées. ALLUMÉ : unité bien connectée CLIGNOTE : unité mal connectée, modification manuelle du câblage entre 2, 3 et 5 requise ALLUMÉ : unité bien connectée CLIGNOTE : unité mal connectée, modification manuelle du câblage entre 2, 3 requise Anormal • Essai de fonctionnement. 1) Si la température est inférieure à 16°C, il est impossible de tester le refroidissement avec la télécommande. De même, si la température est supérieure à 30°C, il est impossible de tester le chauffage. 2) Pour tester le refroidissement, réglez la température la plus basse sur 16°C. Pour tester le chauffage, réglez la température la plus élevée sur 30°C. 3) Veuillez contrôler le fonctionnement du refroidissement et du chauffage de chaque unité, individuellement. Contrôlez également le fonctionnement simultané de toutes les unités intérieures. 4) Après avoir fait fonctionner l'unité pendant environ 20 minutes, vérifiez la température de sortie de l'unité intérieure. 5) Après avoir mis l'unité en arrêt, ou après la modification de son mode de fonctionnement, le système mettra environ 3 minutes avant de redémarrer. 6) Pendant le fonctionnement en refroidissement, il est possible d'observer du gel sur l'unité intérieure ou ses conduits. Ceci est normal. 7) Faites fonctionner l'unité conformément au manuel d'utilisation. Expliquez le fonctionnement à vos clients en vous servant du manuel. • Écran numérique en sept parties 1) Lorsque l'unité est en marche, cet écran numérique affiche la fréquence du compresseur. Par exemple, " signifie que la fréquence de " " signifie que la fréquence de fonctionnement du compresseur est 40 Hz, " fonctionnement du compresseur est 108 Hz. 2) En cas de défaillance, l'écran numérique en sept partie clignote et affiche certains nombres. Ce nombre correspond à un code de défaillance. Par exemple, " " qui clignote, correspond à la défaillance n° 32 c'est-à-dire à une erreur de communication intérieure/extérieure. • Voyant DEL de communication Le voyant DEL 5 vert signifie qu'il y a 5 unités intérieure. Si un seul voyant DEL reste allumé, cela signifie que l'unité intérieure correspondante communique correctement avec l'unité extérieure. Si l'un des voyant DEL ne s'allume pas, cela signifie qu'il n'y a pas de communication intérieure/extérieure. 14 Dépannage Affichage LED exté rieur Raisons possibles Unité extérieure EEPROM défectueuse IPM surintensité ou court circuit Panne de communication entre Module et ECU Câbles de communication brisés ou mal connectés." Surcharge de module exploité Module haute ou basse tension en courant continue (inférieur à 192V ou supérieur à 375V)" Surchauffe de température de décharge.Manque de réfrigérant, température ambiante trop élevée ou PMVs bloqués. » Mauvais fonctionnement du moteur de ventilateur CC Dysfonctionnement du capteur de température de dégivrage Dysfonctionnement du capteur de la température d'aspiration de compresseur Dysfonctionnement du capteur de température ambiante Dysfonctionnement du capteur de température de décharge de compresseur Panne de communication entre l'unité intérieure & extérieure Manque de fréon Échec de commutation de valve à quatre voies Surintensité de module/Échec de commutateur de module Surcharge intérieure Gel intérieur Température de module trop élevé (protecteur contre surcharge) Surintensité de compresseur Surintensité d'entrée Réinitialisation MCU Module de courant pour détecter un mauvais fonctionnement du circuit Dysfonctionnement du capteur de température du liquide de tuyau pour unité intérieure A Dysfonctionnement du capteur de température du liquide de tuyau pour unité intérieure B Dysfonctionnement du capteur de température du liquide de tuyau pour unité intérieure C Dysfonctionnement du capteur de température du liquide de tuyau pour unité intérieure D Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure A Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure B Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure C Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure D Dysfonctionnement du capteur de température de tuyau de gaz pour unité intérieure E Dysfonctionnement du module de capteur de température Dysfonctionnement du capteur de température de condensation Dysfonctionnement du capteur de température du liquide pour unité intérieure E Dysfonctionnement du capteur de température de tuyauterie Déconnexion de système haute pression Déconnexion de système basse pression "Protection contre haute pression du système.Surabondance du réfrigérant, haute température de condensation ou dysfonctionnement du moteur du ventilateur "Protection contre la basse pression du système. Pénurie de réfrigérant, basse température de dé givrage ou dysfonctionnement du moteur du ventilateur. Dysfonctionnement du capteur de température de module 15 Affichage de Cassette et code d'erreur extérieur commande câ pour affichage intérieure convertible utilisent le chronomètre et la lampe blée de course Temps à éclats de lampe de chronomètre Temps à éclats de lampe de course 1 2 4 15 16 18 2 2 2 1 2 4 5 6 8 19 1A 1C 2 2 2 5 6 8 9 10 11 12 13 15 16 17 18 20 21 23 24 25 26 27 28 29 30 31 32 33 34 35 36 38 39 40 41 42 43 44 1D 1E 1F 20 21 23 36 25 26 28 29 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 3A 3B 3C 3D 3E 3F 40 2 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 6 6 6 6 6 9 0 1 2 3 5 6 7 8 0 1 3 4 5 6 7 8 9 0 1 2 3 4 5 6 8 9 0 1 2 3 4 45 41 6 5 46 42 6 6 Adresse : No.1 Haier Road, Hi-tech Zone.Qingdao 266101 P.R.Chine Contacts : Tél. : +86-532-8893-6943 ; Télécopie +86-532-8893-6999 Site Internet : www.haier.com INSTALLATIONSANLEITUNG FÜR MULTI-SPLIT-KLIMAANLAGE Sicherheitsvorkehrungen-------------------- 3 Zubehör ---------------------------------------- 4 Vorsichtsmaßnahmen bei der Wahl des Standortes--------------------------------- 4 Installationsabbildungen der Innen- und Außengeräte------------------------------ 5 Vorsichtsmaßnahmen bei der Installation--------------------------------------- 7 Installationsanleitung für Außengerät----- 7 Beschränkungen bei der Installation------ 7 Verrohrung des Kältemittels---------------- 7 Abpumpbetrieb -------------------------------12 Verdrahtung------------------------------------12 Testlauf------------------------------------------14 Fehlerbehebung - ----------------------------15  Lesen Sie dieses Handbuch vor der Inbetriebnahme bitte sorgfältig durch. Bewahren Sie diese Anleitung für eine spätere Bezugnahme gut auf. Deutsch Inhalt Haier Industrial Park, No.1 Haier Road, Qingdao, VR-China ÜBEREINSTIMMUNG MIT EUROPÄISCHEN VORSCHRIFTEN FÜR DIE MODELLE CE Alle Produkte stimmen mit folgenden europäischen Bestimmungen überein: - Niederspannungsrichtlinie 73/23/EWG - Niederspannungsrichtlinie 2006/95/EWG - Elektomagnetische Verträglichkeit 89/336/EWG - Elektomagnetische Verträglichkeit 2004/108/EWG ROHS Die Produkte stimmen mit den Anforderungen der Richtlinie 2002/95/EWG des Europäischen Parlaments und des Rates zur Beschränkung der Verwendung bestimmter gefährlicher Stoffe in Elektro- und Elektronikgeräten (EG-RoHS-Richtlinie) überein. WEEE Gemäß Richtlinie 2002/96/EG des Europäischen Parlaments informieren wir den Kunden hiermit über die Entsorgungsvorschriften für Elektro- und Elektronikgeräte. ENTSORGUNGSVORSCHRIFTEN: Ihr Klimaanlageprodukt ist mit diesem Symbol gekennzeichnet. Dies bedeutet, dass Elektround Elektronikprodukte nicht zusammen mit dem unsortierten Hausmüll entsorgt werden dürfen. Versuchen Sie nicht, das System zu demontieren: Die Demontage des Klimaanlagesystems, die Handhabung von Kältemittel, Öl und anderer Teile muss von einem qualifizierten Installateur gemäß einschlägiger lokaler und nationaler Vorschriften vorgenommen werden. Klimaanlagen müssen in einer speziellen Aufbereitungsanlage für Wiederverwendung, Recycling und Rückgewinnung aufbereitet werden. Durch Sicherstellung einer sachgemäßen Entsorgung dieses Produkts tragen Sie dazu bei, potentiell negative Auswirkungen auf die Umwelt und die menschliche Gesundheit zu verhindern. Weitere Auskunft erteilt Ihnen gerne der Installateur oder Ihre Behörde vor Ort. Die Batterie muss aus der Fernbedienung hergenommen und gemäß einschlägiger lokaler und nationaler Vorschriften getrennt entsorgt werden. WICHTIGE INFORMATIONEN ZUM VERWENDETEN KÄLTEMITTEL Enthält fluorierte Treibhausgase, die unter das Kyoto-Protokoll fallen Kg Kg Kg Dieses Produkt enthält fluorierte Treibhausgase, die unter das Kyoto-Protokoll fallen. Nicht in die Atmosphäre ablassen. Kältemitteltyp: R410A GWP*-Wert: 1975 GWP=Treibhauspotenzial Bitte mit dokumentenechter Tinte ausfüllen: •1 Die werkseitige Kältemittelladung des Produkts • 2 Die zusätzliche Menge an Kältemittel, die im Installationsbereich nachgefüllt wurde, und • 1+2 Die gesamte Kältemittelladung auf dem mit dem Produkt versehenen Kältemittelladungsetikett. Das ausgefüllte Etikett muss neben dem Ladeport des Produkts aufgeklebt werden (z. B. auf der Innenseite des Sperrventildeckels). A Enthält fluorierte Treibhausgase, die unter das Kyoto-Protokoll fallen B Werkseitige Kältemittelladung des Produkts: Siehe Typenschild des Geräts C Zusätzliche Menge an Kältemittel, die im Installationsbereich nachgefüllt wurde D gesamte Kältemittelladung E Außengerät F Kältemittelzylinder und Anschlussstück zum Nachfüllen Sicherheitsvorkehrungen • Lesen Sie diese Sicherheitsvorkehrungen sorgfältig durch, um eine sachgemäße Installation zu gewährleisten. • In diesem Handbuch sind Sicherheitsvorkehrungen in die Abschnitte WARNUNG und VORSICHT unterteilt. • Achten Sie darauf, alle folgenden Sicherheitsvorkehrungen zu beachten: Sie sind alle wichtig zur Gewährleistung der Sicherheit. WARNUNG Nichtbefolgung einer WARNUNG hat höchstwahrscheinlich schwerwiegende Folgen wie Tod oder schwere Verletzung. VORSICHT Nichtbefolgung einer VORSICHTSMASSNAHME kann in einigen Fällen schwerwiegende Folgen haben. • Folgende Sicherheitssymbole werden insgesamt in diesem Handbuch verwendet: Sie müssen diese Anweisungen unbedingt befolgen. Sie müssen das Gerät auf jeden Fall erden. Nie versuchen. • Überprüfen Sie das Gerät nach vollständiger Installation auf Installationsfehler. Geben Sie dem Benutzer geeignete Anweisungen zur Verwendung und Reinigung des Geräts gemäß der Bedienungsanleitung. WARNUNG • Die Installation sollte vom Händler oder einem Fachmann vorgenommen werden. Bei falscher Installation kann Wasser auslaufen, Stromschlag oder Brand die Folge sein. • Installieren Sie die Klimaanlage gemäß den Anweisungen in diesem Handbuch. Bei unvollständiger Installation kann Wasser auslaufen, Stromschlag oder Brand die Folge sein. • Achten Sie darauf, die mitgelieferten oder vorgegebenen Installationsteile zu verwenden. Bei Verwendung anderer Teile könnte sich das Gerät lösen, ein Wasserleck, ein Stromschlag oder ein Brand entstehen. • Installieren Sie die Klimaanlage auf einer soliden Unterlage, die das Gewicht des Geräts tragen kann. Bei unzureichender Unterlage oder unvollständiger Installation könnten Verletzungen entstehen, wenn das Gerät von der Unterlage herunterfällt. • Elektrische Arbeiten sollten gemäß der Installationsanleitung und den nationalen Vorschriften für elektrische Verdrahtungen oder den Praxisleitfäden vorgenommen werden. Eine unzureichende Kapazität oder eine unvollständige elektrische Verdrahtung kann zu Stromschlag oder Brand führen. • Verwenden Sie auf jeden Fall eine festgeschaltete Stromversorgung. Verwenden Sie nie eine Stromversorgung, mit der auch andere Geräte versorgt werden. • Verwenden Sie für die Verdrahtung ein Kabel, das lang genug ist, die gesamte Distanz ohne Zwischenanschlüsse zu überbrücken. Verwenden Sie keine Verlängerungsschnur. Legen Sie keine anderen Lasten an die Stromversorgung, verwenden Sie eine festgeschaltete Stromversorgung. (Andernfalls kann es zu unnormaler Hitze, Stromschlag oder Brand kommen.) • Verwenden Sie vorgegebene Drahttypen für die elektrischen Verbindungen zwischen den Innen- und Außengeräten. Klemmen Sie die Verbindungsdrähte fest, so dass die Anschlussleisten keiner äußeren Zugkraft ausgesetzt sind. Bei unvollständigen Anschlüssen oder Klemmvorrichtungen kann sich die Anschlussleiste überhitzen oder in Brand geraten. • Achten Sie nach Verbindung der Anschluss- und Versorgungsleitungen darauf, dass sie so verlegt werden, dass sie keine übermäßige Kraft auf elektrische Abdeckungen oder Blenden ausüben. Installieren Sie die Abdeckungen über die Drähte. Bei unvollständiger Installation der Abdeckung kann sich die Anschlussleiste überhitzen, Stromschlag oder Brand die Folge sein. • Ist während der Installation Kältemittel ausgetreten, müssen Sie das Zimmer lüften. (Das Kältemittel erzeugt ein giftiges Gas, wenn es Feuer ausgesetzt wird.) • Prüfen Sie nach vollständiger Installation, dass das Kältemittel nicht ausläuft. (Das Kältemittel erzeugt ein giftiges Gas, wenn es Feuer ausgesetzt wird.) • Bei Installation oder Verlegung des Systems dürfen Sie keine anderen Stoffe, z. B. Luft, in den Kältemittelkreis einführen als das vorgegebene Kältemittel (R410A). (Das Vorhandensein von Luft oder anderer Fremdstoffe im Kältemittelkreis kann zu einem unnormalen Druckanstieg oder zum Aufplatzen und damit zu Verletzungen führen.) • Stoppen Sie während des Abpumpens den Kompressor, bevor Sie die Rohrleitung für das Kältemittel abnehmen. Ist der Kompressor während des Abpumpens weiterhin in Betrieb und das Absperrventil geöffnet, wird Luft eingesaugt, was zu einem unnormalen Druck im Gefrierzyklus führt und ein Aufplatzen des Rohres und sogar Verletzungen verursacht. • Sie müssen das Gerät auf jeden Fall erden. Erden Sie das Gerät nicht über eine Energieversorgungsleitung, den Blitzableiter oder den Schutzleiter eines Telefons. Ist die Erdung unzureichend, kann ein Stromschlag oder ein Brand die Folge sein. Ein Starkstromstoß von einem Blitz oder anderen Quellen kann die Klimaanlage beschädigen. • Sie müssen auf jeden Fall einen Fehlerstromschutzschalter installieren. Wird kein Fehlerstromschutzschalter installiert, besteht die Gefahr eines Stromschlags oder eines Brandes. VORSICHT • Installieren Sie die Klimaanlage nicht an einem Ort, an dem die Gefahr des Kontakts mit brennbaren Gasen bestehen könnte. Wenn Gas ausströmt und sich um das Gerät ansammelt, könnte es einen Brand entfachen. • Verlegen Sie das Abflussrohr gemäß den Anweisungen in diesem Handbuch. Eine unsachgemäße Rohrverlegung kann zu einer Überschwemmung führen. • Ziehen Sie die Ringmutter gemäß der angegebenen Methode an, z. B. mit einem Drehmomentschlüssel. Wird die Ringmutter zu fest angezogen, könnte sie nach längerem Einsatz einreissen, was dazu führt, das Kältemittel ausläuft. • Sorgen Sie unbedingt für geeignete Maßnahmen, die verhindern, dass das Außengerät als Unterschlupf für kleine Tiere verwendet wird. Kleine Tiere, die mit elektrischen Teilen in Kontakt kommen, können Betriebsstörungen, Rauch oder Brand verursachen. Belehren Sie bitte den Kunden, den Bereich um das Gerät sauber zu halten.  Zubehör Beigefügtes Zubehör für Außengerät: Nr. Zeichnung Name des Teils Anzahl Hinweis 1 1 Abflussknie 2 Gummipolster 3 4 1 3 Klammer 3 4 Adapter (3/8 1/2) 1 5 Adapter(1/2 3/8) 1 Vorsichtsmaßnahmen bei der Wahl des Standortes 1) Wählen Sie eine Stelle, die stark genug ist, das Gewicht und die Vibrationen des Geräts zu tragen, und wo das Betriebsgeräusch nicht verstärkt wird. 2) Wählen Sie eine Stelle, wo abgegebene Heißluft oder das Betriebsgeräusch weder die Nachbarn noch den Benutzer stört. 3) Vermeiden Sie Orte wie Schlafzimmer und ähnliche Zimmer, wo das Betriebsgeräusch sich nicht störend auswirkt. 4) Es muss genügend Platz vorhanden sein, das Gerät zum Aufstellungsort zu tragen und von ihm wegzutragen. 5) Es muss ausreichend Platz für einen Luftdurchlass vorhanden und der Luftein- und -auslass darf nicht blockiert sein. 6) Es dürfen sich keine entzündbaren Gase in der Nähe des Aufstellungsortes befinden. Stellen Sie das Gerät so auf, dass weder Betriebslärm noch Heißluft die Nachbarn stört. 7) Installieren Sie Geräte, Stromleitungen und Leitungen zwischen den Geräten in einem Abstand von mindestens 3 Metern von Fernseh- und Radiogeräten. Auf diese Weise werden Bild- und Tonstörungen vermieden. (Je nach Radiowellen könnten Störungen auch bei einem Abstand über 3 Meter möglich sein.) 8) In Küstengebieten oder anderen Orten mit salzhaltiger Luft oder schwefelhaltigen Gasen kann sich die Lebenszeit der Klimaanlage aufgrund von Korrosion verkürzen. 9) Da Abwasser aus dem Außengerät läuft, stellen Sie keine Gegenstände unter das Gerät, die nicht der Feuchtigkeit ausgesetzt werden dürfen. HINWEIS: Darf nicht hängend von der Decke oder gestapelt installiert werden. VORSICHT Setzen Sie die Klimaanlage bei niedriger Außentemperatur in Betrieb, beachten Sie bitte die folgenden Anweisungen. 1) Um Windeinwirkung zu vermeiden, installieren Sie das Außengerät so, dass seine Ansaugseite zur Wand weist. 2) Installieren Sie das Außengerät nie an einer Stelle, wo seine Ansaugseite direkt dem Wind ausgesetzt ist. 3) Um Windeinwirkung zu vermeiden, wird die Anbringung einer Ablenkplatte auf der Luftauslassseite des Außengeräts empfohlen. 4) In Regionen mit starkem Schneefall wählen Sie bitte eine Installationsstelle, wo der Schnee nicht das Gerät beeinträchtigt. • Errichten Sie eine große Abdeckhaube. • Errichten Sie einen Sockel.  Installieren Sie das Gerät so hoch über den Boden, dass es nicht vom Schnee begraben werden kann. Installationsabbildungen der Innen- und Außengeräte Siehe bitte 4U30HS1ERA für Installationsabbildung M eh ra ls 10 Mehr als 5 cm 1. Verbinden Sie nicht das eingebettete Abzweigrohr und das Außengerät, wenn Sie nur Rohrarbeiten ohne angeschlossenes Innengerät ausführen, um später ein weiteres Innengerät hinzuzufügen. Achten Sie darauf, dass weder Schmutz noch Feuchtigkeit in eine der beiden Seiten des eingebetteten Abzweigrohrs gelangt. 2. Es ist nicht möglich, das Innengerät nur für ein Zimmer anzuschließen. cm Anordnung der Rohrrichtungen Hinten links Links Hinten rechts Rechts Unterhalb Beachtung muss dem aufsteigenden Abflussschlauch geschenkt werden Umwickeln Sie das Isolierrohr von unten bis oben mit dem Abdeckband. Schneiden Sie das Wärmeisolierrohr auf eine passende Länge zu und umwickeln Sie es mit Isolierband, um zu sicherzustellen, dass die Schnittlinie des Isolierrohrs komplett isoliert ist. cm als 10 Mehr Me hr a ls 10 c m hr Me m 0c ls 6 a hr Me als m c 25  Besteht die Gefahr, dass das Gerät umkippen oder herunterfallen könnte, befestigen Sie es mit Fundamentschrauben, Drähten oder anderen Mitteln. Ist am Aufstellungsort kein guter Abfluss vorhanden, stellen Sie das Gerät auf einen ebenen Montagesockel (oder einen Kunststoffsockel). Installieren Sie das Außengerät auf einer waagerechten Ebene. Andernfalls könnte Wasser auslaufen oder sich ansammeln. Installationsabbildungen der Innen- und Außengeräte Vorsichtshinweise für den Anschluss Modell Anschlusspriorität zwischen Innengerät und höherem Absperrventil von unten nach oben Bei 1 Innengerät ist das C D E prioritäre Absperrventil Bei 2 Innengeräten CB DC ED sind die prioritären Absperrventile Bei 3 Innengeräten CBA DCB EDC sind die prioritären Absperrventile Bei 4 Innengeräten DCBA EDCB sind die prioritären Absperrventile Bei 5 Innengeräten E D C B-A sind die prioritären Absperrventile Hinweis: Für eine bessere Ölrückkehr und ein zuverlässigeres System gehen Sie beim Anschluss des Innengeräts bitte gemäß obiger Beschreibung vor.  Vorsichtsmaßnahmen bei der Installation • Prüfen Sie die Stärke und Ebenmäßigkeit des Installationsbodens, so dass das Gerät nach der Installation weder Vibrationen noch Lärm während des Betriebs erzeugt. • Befestigen Sie das Gerät gemäß der Fundamentzeichnung mit Fundamentschrauben. (Dazu benötigen Sie vier Sets von M8 oder M10 Fundamentschrauben, Muttern und Unterlegscheiben, die alle im Handel erhältlich sind.) • Am besten drehen Sie die Fundamentschrauben so weit ein, bis sie 20 mm vom Fundament abstehen. Installationsanleitung für Außengerät • An Stellen, an denen eine Wand oder eine andere Behinderung den Pfad des Luftein- oder -auslasses des Geräts behindert, halten Sie sich bitte an die folgenden Hinweise zur Installation. • Für jede der nachstehenden Installationsmethoden sollte die Wandhöhe auf der Abluftseite maximal 1200 mm betragen. Wand auf einer Seite Mehr als 300 Mehr als 50 1200 oder darunter Seitenansicht Wand auf drei Seiten Wand auf beiden Seiten Mehr als 100 Mehr als 150 Mehr als 300 Mehr als 100 Mehr als 50 Seitenansicht Mehr als 300 Mehr als 50 Seitenansicht Beschränkungen bei der Installation 1. Vorsichtsmaßnahmen bei der Installation • Prüfen Sie die Stärke und Ebenmäßigkeit des Installationsbodens, so dass das Gerät nach der Installation weder Vibrationen noch Lärm während des Betriebs erzeugt. • Befestigen Sie das Gerät gemäß der Fundamentzeichnung mit Fundamentschrauben. • Am besten drehen Sie die Fundamentschrauben so weit ein, bis sie 20 mm vom Fundament abstehen. 2. Wahl eines Standortes für die Installation der Innengeräte • In der folgenden Liste ist die maximal zulässige Länge des Kältemittelrohrs und der maximal zulässige Höhenunterschied zwischen den Außen- und Innengeräten angegeben. (Je kürzer das Kältemittelrohr ist, desto besser ist die Leistung. Machen Sie den Rohranschluss so kurz wie möglich. Die kürzeste zulässige Länge pro Zimmer beträgt 3 m.) Außengerätkapazitätsklasse max. max. max. max. Rohrgesamtlänge zwischen allen Geräten max. max. max. max.  Rohrleitung zu jedem Innengerät Beschränkungen bei der Installation Innengerät Außengerät Niveauunterschied: max. 15m Niveauunterschied: max. 15m Niveauunterschied: max. 7,5 m Niveauunterschied: max. 7,5 m Außengerät Innengerät Wenn das Außengerät höher steht als die Innengeräte. (Niedriger als ein oder mehrere Innengeräte.) Wenn das Außengerät höher steht als die Innengeräte. Innengerät Niveauun- Niveauunterschied: terschied: max. 15m max. 7,5 m Außengerät Wenn das Innengerät höher steht als die Außengeräte. Verrohrung des Kältemittels 1. Installation des Außengeräts 1) Beziehen Sie sich für die Installation des Außengeräts auf die Abschnitte "Vorsichtsmaßnahmen bei der Wahl des Standortes" und "Installationsabbildungen der Innen- und Außengeräte". 2) Sind Arbeiten am Abfluss erforderlich, beachten Sie die folgenden Schritte. 2. Arbeiten am Abfluss 1) Verwenden Sie einen Ablasshahn für den Abfluss. 2) Wird der Abflussanschluss vom Montagesockel oder der Bodenfläche verdeckt, bringen Sie zusätzlich Fußsockel in einer Höhe von mindestens 30 mm unter den Füßen des Außengeräts an. 3) Bringen Sie in kalten Regionen keinen Abflussschlauch an das Außengerät an. (Andernfalls könnte das Abflusswasser gefrieren und die Heizleistung beeinträchtigen.) Schlauch Schlauch Abflussknie  Abflussknie Verrohrung des Kältemittels 3. Verrohrung des Kältemittels 1) Richten Sie die Mitten beider Bördeln miteinander aus und ziehen Sie die Ringmuttern 3 oder 4 Umdrehungen mit der Hand an. Ziehen Sie sie dann mit einem Drehmomentschlüssel fest an. Ziehen Sie die Ringmuttern mithilfe von Drehmomentschlüsseln an, um die Ringmuttern nicht zu beschädigen, wodurch Gas entweichen könnte. Drehmomentschlüssel Anziehdrehmoment für Ringmutter Ringmutter für 6,35 14,2-17,2 Nm (144-175 kgf.cm) Ringmutter für 9,52 32,7-39,9 Nm (333-07 kgf.cm) Ringmutter für 12,7 49,5-60,3 Nm (505-615 kgf.cm) Ringmutter für 15,88 61,8-75,4 Nm (630-769 kgf.cm) Anziehdrehmoment für Ventilkappe Flüssigkeitsrohr 26,5-32,3 Nm (270-330 kgf.cm) Gasleitung 48,1-59,7 Nm (490-610 kgf.cm) Tragen Sie hier Kühlmittelöl auf Schlüssel Anziehdrehmoment für Abdeckung der Wartungsöffnung Rohrverbindung Konusmutter 10,8-14,7 Nm (110-150 kgf.cm) 2) Um ein Gasleck zu vermeiden, tragen Sie Kühlmittelöl innen und außen auf der Bördelung auf. (Verwenden Sie Kühlmittelöl für R410A.) 4. Beseitigung von Luft und Überprüfung auf Gasleck Nach den Rohrarbeiten muss die Luft beseitigt und nach ausströmendem Gas gesucht werden. WARNUNG 1) Geben Sie keine anderen Stoffe als das vorgegebene Kältemittel (R41OA) in den Kühlzyklus. 2) Wenn Kältemittelgas ausströmt, lüften Sie das Zimmer möglichst früh und möglichst lange. 3) R410A und auch andere Kältemittel müssen immer aufgefangen und dürfen nie in die Umgebung abgelassen werden. 4) Verwenden Sie eine Vakuumpumpe ausschließlich für R41OA. Wenn Sie dieselbe Vakuumpumpe für andere Kältemittel verwenden, kann die Vakuumpumpe oder das Gerät beschädigt werden. • Wenn Sie Kältemittel bemischen möchten, beseitigen Sie die Luft aus den Kältemittelrohren und dem Innengerät mit einer Vakuumpumpe und füllen Sie dann zusätzliches Kältemittel nach. • Betätigen Sie die Absperrventilspindel mit einem Sechskantschlüssel (4 mm). • Alle Kältemittelrohrverbindungen müssen mit einem Drehmomentschlüssel mit dem vorgegebenen Anziehdrehmoment fest angezogen werden. Verbinden Sie die Überhangseite des Befüllungsschlauchs (der vom Anschlussstück der Messgeräts kommt) mit der Wartungsöffnung des Gasabsperrventils. Öffnen Sie ganz das Unterdruckventil des Anschlussstücks vom Messgerät (Lo) und schließen Sie ganz sein Überdruckventil (Hi). (Hiernach braucht das Überdruckventil nicht betätigt zu werden.) Setzen Sie die Vakuumpumpe an. Achten Sie darauf, dass der Verbunddruckmesser auf -0,1 MPa (-76 cmHg) steht. Es wird ein Abpumpen von mindestens 1 Stunde empfohlen. Schließen Sie das Unterdruckventil des Anschlussstücks vom Messgerät (Lo) und stoppen Sie die Vakuumpumpe. (Warten Sie 4-5 Minuten und vergewissern Sie sich, dass sich die Messnadel des Anschlussstücks nicht zurücksetzt. Setzt sie sich dennoch zurück, könnte Feuchtigkeit oder ein Leck bei den Verbindungsteilen vorhanden sein. Überprüfen Sie alle Verbindungen, ziehen Sie die Muttern neu fest an und wiederholen Sie die Schritte 2-4.) Entfernen Sie die Kappen vom Flüssigkeitsabsperrventil und vom Gasabsperrventil. Drehen Sie die Spindel des Flüssigkeitsabsperrventils mit einem Sechskantschlüssel 90 Grad gegen den Uhrzeigersinn, um das Ventil zu öffnen. Schließen Sie es nach 5 Sekunden und suchen Sie nach Gaslecks. Suchen Sie mittels Seifenlauge nach Gaslecks an den Bördelungen des Innen- und des Außengeräts und den Ventilspindeln. Wischen Sie nach Prüfung die gesamte Seifenlauge weg. Trennen Sie den Befüllungsschlauchs von der Wartungsöffnung des Gasabsperrventils und öffnen Sie dann ganz die Flüssigkeits- und Gasabsperrventile. (Drehen Sie die Ventilspindel nur bis zu ihrem Anschlag und nicht darüber hinaus.)  Ziehen Sie die Ventilkappen und die Wartungsöffnungkappen der Flüssigkeits- und Gasabsperrventile mit einem Drehmomentschlüssel mit den vorgegebenen Anziehdrehmomenten fest an. Details hierzu siehe "3 Verrohrung des Kältemittels" auf Seite 6. Verrohrung des Kältemittels 5. Nachfüllen von Kältemittel Verwenden Sie das Kältemittel, das auf dem Typenschild des Geräts angegeben ist. Vorsichtsmaßnahmen beim Nachfüllen von R410A Füllen Sie über das Flüssigkeitsrohr in flüssiger Form nach. Handelt es um ein Kältemittelgemisch und füllen Sie es in Gasform nach, kann sich die Zusammensetzung des Kältemittels ändern und den Normalbetrieb verhindern. 1) Prüfen Sie vor dem Nachfüllen, ob ein Siphon an dem Zylinder angebracht ist. (Er sollte mit "Siphon zum Nachfüllen von Flüssigkeit angebracht" oder Ähnlichem beschriftet sein.) Befüllen anderer Zylinder Befüllen Sie einen Zylinder mit angebrachtem Siphon Stellen Sie den Zylinder zum Befüllen aufrecht hin. Drehen Sie den Zylinder zum Befüllen auf den Kopf. Da sich im Innern ein Ansaugrohr befindet, braucht der Zylinder zum Befüllen mit Flüssigkeit nicht auf den Kopf gedreht werden. 2) Achten Sie auf Verwendung der R41OA-Werkzeuge, um den richtigen Druck zu erhalten, und verhindern Sie, das Fremdobjekte eindringen. 6. Nachfüllen von Kältemittel 1) Dieses System verwendet das Kältemittel R410A. 2) Füllen Sie das Kältemittel in einer Menge von 20 g pro Meter nach, wenn die Gesamtrohrlänge den Standardwert überschreitet, aber achten Sie darauf, dass die Gesamtrohrlänge für die Flüssigkeit nicht den Maximalwert überschreitet. Außengerät StandardlgesamtänMax. Gesamtänge der ge der FlüssigkeitsFlüssigkeitsleitung leitung Hinweise: 1) Für den Betrieb dieses Produkts brauchen Sie keine Adresse einzustellen. Doch müssen die UN-Drähte der Innen- und Außengeräte zueinander passen, denn sonst kommt es zu Kommunikationsfehlern. 2) Einstellung des ruhigen Betriebsverlaufs. Setzen Sie den DIP-Schalter "8" von SW5 auf ON (Ein), reduziert sich das Betriebsgeräusch des Systems; allerdings verringert sich dann auch leicht die maximale Betriebsleistung. 3) Ändern Sie nicht die Einstellungen der anderen Switche, denn falsche Einstellungen können das System beschädigen oder andere Betriebsstörungen verursachen. 7. Vorsichtsmaßnahmen beim Verlegen des Kältemittelrohrs • Sicherheitshinweise für die Rohrhandhabung 1) Schützen Sie das offene Ende des Rohrs vor Schmutz und Feuchtigkeit. 2) Alle Rohrverbiegungen müssen so vorsichtig wie möglich ausgeführt werden. Verwenden Sie zum Verbiegen ein Rohrbiegewerkzeug. (Der Biegeradius sollte 30 bis 40 mm oder mehr betragen.) • Wahl von Kupfer- und Wärmeisoliermaterialien Beachten Sie Folgendes bei der Verwendung von handelsüblichen Kupferrohren und dem Zubehör: 1) Isoliermaterial: Polyäthylen-Schaumstoff (PE) Wärmeübergangszahl: 0,041 bis 0,052 W/mK (0,035 bis 0,045 kcal/mh°C) Die Außentemperatur der Gasrohrleitung des Kältemittels erreicht maximal 110°C. Wählen Sie Wärmeisoliermaterialien, die dieser Temperatur standhalten. 2) Gas- und Flüssigkeitsleitung müssen auf jeden Fall isoliert werden, wobei die folgenden Isoliermaße beachtet werden müssen. Gasleitung Isolierung der Gasleitung Außendurchm.: 9,52 mm, Innendurchm.:12-15 mm, 12,7 12,7 mm mm Dicke: 0,8 mm Dicke: Min. 13mm Flüssigkeitsrohr Isolierung des Flüssigkeitsrohrs Außendurchm.: 6,35 mm Innendurchm.: 18-10 mm Dicke: 0,8 mm Dicke: Min. 10 mm 10 Rohrarbeiten für Kältemittel 3) Verwenden Sie getrennte Wärmeisolierrohre für das Gas- und das Flüssigkeitskältemittelrohr. Verdrahtung zwischen den Geräten Gasleitung Regen Ist keine Bördelkappe verfügbar, verschließen Sie die Bördelöffnung mit einem Band, damit kein Schmutz oder Wasser eindringen kann. Isolierung des Flüssigkeitsrohrs Isolierung der Gasleitung Abdeckband Wand Setzen Sie unbedingt eine Kappe auf. Flüssigkeitsrohr Abflussschlauch Prüfen Sie Innenfläche der Bördelung muss fehlerfrei sein. Das Rohrende muss in einem perfekten Kreis gleichmäßig gebördelt sein. Schneiden Sie genau rechtwinklig zu. Grate entfernen Die Ringmutter muss angebracht sein. Genau in nachstehender Position einsetzen. Bördelwerkzeug für R410A Herkömmliches Bördelwerkzeug Mit Flügelmutter Mit Greifer Mit Greifer (starrr) (traditionell) Bördelwerkzeugform 0-0,5mm 1,0-1,5mm 1,5-2,0 mm 8. Zuschneiden und Bördeln der Rohre • Rohre werden mit einem Rohrschneider zugeschnitten und Grate müssen entfernt werden. • Nach dem Einfügen der Ringmutter wird gebördelt. Rohr Bördelwerkzeugform Flüssigkeitsseite Gasseite Rohrdurchmesser Größe A (mm) 6,35mm (1/4") 0.8-1.5 9,52mm (3/8") 12,7 mm (1/2") 1.0-1.5 1.0-1.5 Richtig Schief Bördel beschädigt Falsch Angeris- Unvollsen ständig Zu weit nach außen 9. Abfluss • Installieren Sie den Abflussschlauch bitte so, dass er auf jeden Fall abwärts geneigt ist. Installieren Sie den Abfluss bitte nicht so, wie nachstehend abgebildet ist. Unter 5 cm Wird in der Mitte zu hoch. Das Ende ist in Wasser eingetaucht Abstand zum Boden ist zu gering. Ist wellig. Schlechter Geruch steigt aus einem Abwassergraben auf. • Gießen Sie Wasser in die Ablaufwanne des Innengeräts und überzeugen Sie sich davon, dass der Abfluss sachgemäß nach außen führt. • Sollte sich der angebrachte Abflussschlauch in einem Zimmer befinden, müssen Sie ihn wärmeisolieren. WARNUNG 1) Tragen Sie kein Mineralöl auf die Bördelung auf. 2) Achten Sie darauf, dass das Mineralöl nicht in das System eindringt, denn dadurch verkürzt sich die Lebenszeit der Geräte. 3) Verwenden Sie keine Rohrleitungen, die bereits für frühere Installationen verwendet wurden. Verwenden Sie nur die Teile, die Sie zusammen mit dem Gerät erhalten haben. 4) Installieren Sie nie einem Entfeuchter an diesem R41OA-Gerät, um nicht seine Lebenszeit zu verkürzen. 5) Das Trockengut könnte sich auflösen und das System beschädigen. 6) Unvollständige Bördelung kann zu ausströmendem Kältemittelgas führen. 11 Abpumpbetrieb Zum Schutz der Umwelt müssen Sie abpumpen, wenn Sie das Gerät umstellen oder entsorgen. 1) Entfernen Sie die Ventilkappen vom Flüssigkeitsabsperrventil und vom Gasabsperrventil. Flüssigkeitsabsperrventil 2) Nehmen Sie eine Zwangskühlung vor. 3) Schließen Sie das Flüssigkeitsabsperrventil nach fünf bis zehn Minuten mit einem Sechskantschlüssel. 4) Schließen Sie das Gasabsperrventil nach zwei bis drei Minuten und stoppen Sie die Zwangskühlung. Gasabsperrventil Sechskantschlüssel Schließen Ventilkappe Verdrahtung 1. Elektrische Verdrahtung • Die Klimaanlage muss an einen Sonderstromkreis angeschlossen werden, wobei die Verdrahtung von einem qualifizierten Elektriker gemäß den im nationalen Standard vorgegebenen Verdrahtungsvorschriften ausgeführt werden muss. • Schutzleiter und Nullleiter müssen strikt voneinander getrennt werden. Der Anschluss des Nullleiters an den Schutzleiter ist falsch. • Es muss ein Fehlerstromschutzschalter installiert werden. • Bei allen elektrischen Drähten muss es sich um Kupferdrähte handeln. Stromversorgung: 1PH, 220-230V-, 50Hz. • Die Netzleitung wird als Y-Anschluss verdrahtet. Ist die Netzleitung beschädigt, muss sie vom Hersteller, seinem Reparaturdienst oder einer ähnlich qualifizierten Person ersetzt werden, um keinen Stromschlag zu verursachen. Die Anschlussleitung muss abgeschirmt sein. Sicherung: T3.15A250VAC T16A250VAC (beziehen Sie sich bitte auf den Schaltplan des Außengeräts) • Beziehen Sie sich bitte auf den Schaltplan hinsichtlich der zu ersetzenden Sicherung. 2. Verdrahtungsmethode • Verdrahtungsmethode bei kugelförmigen Anschlussleisten: Anschlussdrähte werden anhand der rechts abgebildeten Methode mit kugelförmigen Anschlussleisten verbunden: Entfernen Sie die Anschlussschraube, stecken Sie die Schraube durch den Ring am Drahtende, schließen Sie dann die Anschlussleiste und ziehen Sie die Schraube fest an. Verdrahtungsmethode bei geraden Anschlussleisten: • Verdrahtungsmethode für Anschlussdraht ohne kugelförmige Anschlussleisten: Lösen Sie die Verbindungsschraube, stecken Sie ein Ende des Anschlussdrahts ganz in die Anschlussleiste und ziehen Sie dann die Schraube an. Ziehen Sie den Draht ein wenig heraus, um sicherzustellen, dass er befestigt ist. • Crimpverbindungsmethode für Drähte ohne Anschlussleisten Verbinden Sie den Draht mit demselben Durchmesser mit den beiden Seiten der Anschlussleiste Verbinden Sie nicht den Draht mit demselben Durchmesser mit derselben Seite Verdrahtungsmethod für Ring-Anschlussleiste Richtiger Druck Verbinden Sie keine Drähte mit unterschiedlichen Durchmessern Falscher Druck Anschlussleiste Druckklammern • Crimpverbindungsmethode für Anschlussdraht: Nach dem Anschluss muss der Draht mit der Kabelabdeckung befestigt werden. Die Kabelabdeckung sollte auf die Schutzbeschichtung des Anschlussdrahts drücken, wie oben rechts abgebildet ist. Hinweis: Achten Sie beim Anschluss der Drähte genau auf die Anschlussnummer der Innen- und Außengeräte. Bei unsachgemäßer Verdrahtung wird die Steuereinheit der Klimaanlage beschädigt oder das Gerät lässt sich nicht bedienen. 3. Verdrahtungsmethode beim Außengerät: • Netzleitung Entfernen Sie die Reparaturplatine des Außengeräts und lösen die Kabelabdeckung A. Ziehen Sie dann den Nullleiter und den Schutzleiter durch die Kabelabdeckung und schließen Sie diese auf entsprechende Weise an die Anschlussleiste an. Bringen Sie die Kabelabdeckung nach dem Anschluss wieder so an, wie sie zuvor befestigt war. Kommunikationsdraht des Innengeräts. • Lösen Sie die Kabelabdeckung, stecken Sie den Kommunikationsdraht durch die Kabelabdeckung B und verbinden Sie ihn auf entsprechende Weise mit der Anschlussleiste. Bringen Sie die Kabelabdeckung B nach dem Anschluss wieder so an, wie sie zuvor befestigt war. Hinweis: Netzleitung und Kommunikationsdraht müssen vom Kunden bereitgestellt werden. 12 Verdrahtung Kabelabdeckung A KabelabAnschlussleiste deckung C KabelabdecKabelabdecKabelabkung D kung B deckung E Ventilabdeckung Kabelabdeckung A Kabelabdeckung C Kabelabdeckung B Anschlussleiste Ventilabdeckung –¨ 25.40 0 4. Verdrahtungsmethode beim Innengerät Lösen Sie die Kabelabdeckung und verbinden Sie die Netzleitung und den Kommunikationsdraht des Innengeräts auf entsprechende Weise mit der Anschlussleiste. Hinweis: Beachten Sie bei der Verbindung der Netzleitung an die Stromversorgung die folgenden Punkte: • Verbinden Sie keine Netzleitung mit abweichenden Maßen an dasselbe Ende des Anschlussdrahts. Ein unsachgemäßer Kontakt erzeugt Hitze. • Verbinden Sie keine Netzleitung mit abweichenden Maßen an dasselbe Ende des Schutzleiters. Ein unsachgemäßer Kontakt beeinträchtigt die Schutzwirkung. • Verbinden Sie die Netzleitung nicht mit dem Anschlussende des Kommunikationsdrahts. Bei unsachgemäßem Anschluss wird das angeschlossene Gerät beschädigt. 5. Beispiel eines Schaltplans. Beziehen Sie sich für den Schaltplan bitte auf 5U34HS1 ERA Verlegen Sie die Drähte so, dass die Serviceklappe oder andere strukturelle Teile nicht angehoben werden. Befestigen Sie die Abzweigverdrahtung fest mit den 4 beigefügten Schrauben, wie abgebildet ist. Achten Sie auf eine gute Befestigung, wobei kein Druck von außen auf die Anschlussleisten ausgeübt werden darf. 13 Verwenden Sie die vorgegebenen Drähte und schließen Sie sie sachgemäß an. Testlauf • Überzeugen Sie sich bitte vor dem Teststart, dass folgende Arbeiten erfolgreich ausgeführt wurden. 1) Richtige Rohrverlegung; 2) Richtige Verdrahtung; 3) Richtige Anpassung beim Innen- und Außengerät; 4) Sachgemäßes Nachfüllen des Kältemittels, sofern erforderlich. • Vergewissern Sie sich, dass alle Absperrventile ganz geöffnet sind. • Überzeugen Sie sich anhand einer Prüfung davon, dass die Innen- und Außengeräte mit einer Spannung von 230 Volt versorgt werden. • Prüfung auf Verdrahtungsfehler Dieses Produkt ist in der Lage, eine automatische Prüfung auf Verdrahtungsfehler vorzunehmen. Schalten Sie alle 4 Dip-Switche auf der kleinen Service-Leiterplatte im Außengerät ein (ON), wie rechts abgebildet ist. Schalten Sie das Gerät dann aus und wieder ein, woraufhin das System mit der "Prüfung auf Verdrahtungsfehler" beginnt. Nach 3 Minuten im Standby-Betrieb beginnt das Gerät automatisch mit der Verdrahtungsprüfung. Etwa 30-50 Minuten (je nachdem, wieviele Geräte im System installiert sind) nach dem Gerätestart werden die Verdrahtungsfehler anhand von LEDs (1 bis 5) aufgezeigt. Während dieses Vorgangs werden abwechselnd die Betriebsfrequenz des Kompressors mittels Digitalziffer (z. B. 50 steht für die aktuelle Betriebsfrequenz) und die Buchstaben "CH" (stehen für "Check" (Prüfung)) angezeigt. Ist die gesamte Verdrahtung fehlerfrei wird nach diesem Vorgang die Digitalziffer "0" angezeigt; und ist etwas in der Verdrahtung falsch, werden die Buchstaben "EC" ("Error connection" (Fehlerverbindung)) blinkend angezeigt. Die Serviceüberwachungs-LEDs zeigen den Verdrahtungsfehler an, wie in folgender Tabelle dargestellt ist. Details zum Lesen der LED-Anzeige sind im Servicehandbuch angegeben. Ist eine Selbstprüfung des Geräts nicht möglich, prüfen Sie ganz normal die Verdrahtung und die Rohre des Innengeräts. LED 1 2 3 AUS 4 5 ALLE blinken ALLE EIN Status EIN BLINKT BLINKT EIN BLINKT EIN BLINKT BLINKT EIN EIN Nur eine LED blinkt Meldung Gerät nicht angeschlossen Automatische Prüfung nicht möglich, alle Geräte falsch angeschlossen Alle Geräte sind richtig angeschlossen EIN:Gerät richtig angeschlossen BLINKT: Gerät falsch angeschlossen, Verdrahtung muss zwischen 2, 3 und 5 manuell geändert werden EIN: Gerät richtig angeschlossen BLINKT: Gerät falsch angeschlossen, Verdrahtung muss zwischen 2 und 3 manuell geändert werden Unnormal • Testlauf. 1) Ist die Temperatur niedriger als 16°C, ist es nicht möglich den Kühlvorgang mit der Fernbedienung zu testen; auch wenn die Temperatur höher ist als 30°C, kann der Heizvorgang nicht getestet werden. 2) Zum Testen des Kühlvorgangs setzen Sie die niedrigste Temperatur auf 16°C. Zum Testen des Heizvorgangs setzen Sie die höchste Temperatur auf 30°C. 3) Prüfen Sie jeweils den Kühlvorgang und den Heizvorgang jedes einzelnen Geräts und prüfen Sie auch den Simultanbetrieb aller Innengeräte. 4) Prüfen Sie nach einem Gerätebetrieb von etwa 20 Minuten die Auslasstemperatur des Innengeräts. 5) Wurde das Gerät angehalten oder die Betriebsart geändert, lässt sich das System ca. 3 Minuten lang nicht neu starten. 6) Während der Betriebsart Kühlen kann sich Frost auf dem Innengerät oder den Rohrleitungen bilden, was ganz normal ist. 7) Bedienen Sie das Gerät gemäß der Bedienungsanleitung. Erklären Sie unseren Kunden bitte die Bedienung mithilfe der Bedienungsanleitung. • Siebenstellige numerische Anzeige 1) Ist das Gerät in Betrieb, zeigt die siebenstellige numerische Anzeige die Frequenz des Kompressors an. Zum Beispiel steht " " für eine Betriebsfrequenz des Kompressors von 40 Hz, " " steht für eine Betriebsfrequenz des Kompressors von 108 Hz. 2) Wenn ein Betriebsfehler auftritt, blinkt die siebenstellige numerische Anzeige und zeigt einige Zahlen an, die den Fehlercode darstellen. Wenn zum Beispiel " " blinkt, liegt ein Fehler Nr. 32 vor, ein Kommunikationsfehler beim Innen- und Außengerät. • Kommunikations-LED 5 grüne LEDs stehen für 5 Innengeräte. Leuchtet eine LED, steht das entsprechende Innengerät in guter Kommunikation mit dem Außengerät. Leuchte eine LED nicht, gibt es keine Kommunikation zwischen dem Innen- und dem Außengerät. 14 Fehlerbehebung kabelgebun Die fuer Fehlercode vom Kassette Aussen und umsetzbar Innenbildschirm im denen LED Bildschirm Controller- Freien verwendete Zeitnahme- und Bildschirm Betriebslampe Mögliche Gründe Fehler der Außeneinheit EEPROM IPM Überstrom oder Kurzschluss Ausfall der Kommunikation zwischen Modul und ECU Kommunikations-Kabel defekt oder nicht richtig angeschlossen Überlastung der betriebenen Module Modul mit niedrigen oder hohen Gleichspannung (unterhalb 192V oder oberhalb 375V) Überhitzungsauslaßtemperatur. Zu wenig Kältemittel, zu hoch Umgebungstemperatur oder PMVs blockiert Fehlfunktion des DC Lüftermotor Fehlfunktion vom entfrostenden Temparatursensor Fehlfunktion vom Temparatursensor an der Verdichtersaugseite Störung des Umgebungs-Temparatursensors Störung des Verdichters-Temparatursensors Kommunikationsfehler zwischen Innen- und Außengerät Mangelnde Freon Einschaltungsfehler vom 4- Wege-Ventil Module-Überstrom / Module-Umschaltungsausfall Innen Überlastung Innen bereift Module-Temperatur zu hoch ( überlastende Schutzeinrichtung) Überstrom vom Kompressor Eingangs-Überstrom MCU auf Null stellen Fehlfunktionen der Erkennungsschaltung fuer Modulestrom Störung des Temparatursensors der Flüssigkeitsleitung für Inneneinheit A Störung des Temparatursensors der Flüssigkeitsleitung für Inneneinheit B Störung des Temparatursensors der Flüssigkeitsleitung für Inneneinheit C Störung des Temparatursensors der Flüssigkeitsleitung für Inneneinheit D Störung des Temparatursensors der Gasleitung für Inneneinheit A Störung des Temparatursensors der Gasleitung für Inneneinheit B Störung des Temparatursensors der Gasleitung für Inneneinheit C Störung des Temparatursensors der Gasleitung für Inneneinheit D Störung des Temparatursensors der Gasleitung für Inneneinheit E Störung des Moduls-Temparatursensors Störung vom kondensierenden Temparatursensor Fehlfunktion des flüssigen Leitungstemparatursensors für Inneneinheit E Fehlfunktionen von Rohrleitungs-Temparatursensor Systemsausschaltung bei hohem Druck Systemsausschaltung bei niedrigem Druck Systems- Hochdruck-Schutz. Kältemittels-Überfluss, hohe kondensierende Temparatur oder Fehlfunktion des Lüftermotors Systems-Niederdruck-Schutz. Kältemittelmangel, niedrige Abtautemperatur, Oder eine Fehlfunktion des Lüftermotors Störung des Moduls-Temparatursensors 15 1 2 4 15 16 18 Blinkszeit von Zeitnahmeslampe 2 2 2 Blinkszeit von Betriebslampe 1 2 4 5 6 19 1A 2 2 5 6 8 1C 2 8 9 10 11 12 13 15 16 17 18 20 21 23 24 25 26 27 28 29 30 31 32 33 34 35 36 38 39 40 41 42 43 44 1D 1E 1F 20 21 23 36 25 26 28 29 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 3A 3B 3C 3D 3E 3F 40 2 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 6 6 6 6 6 9 0 1 2 3 5 6 7 8 0 1 3 4 5 6 7 8 9 0 1 2 3 4 5 6 8 9 0 1 2 3 4 45 41 6 5 46 42 6 6 Adresse: No.1 Haier Road, Hi-tech Zone, Qingdao 266101, VR-China Kontakt: TEL +86-532-8893-6943; FAX +86-532-8893-6999 Website: www.haier.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82

Haier 3U19FS1ERA Guía de instalación

Categoría
Acondicionadores de aire de sistema dividido
Tipo
Guía de instalación
Este manual también es adecuado para