Quiet Fan Control
Ratings: 120 VAC, 1.6 A, 60 Hz
3-Speed Rotary Control
Model 27180
Read and save these instructions.
Caution: Risk of Electrical Shock!
All wiring must be performed in accordance with
national and local electrical codes. Use only to control a
single ceiling fan.
This product conforms to UL Standard 1917.
Notes:
1. For use only with electrically reversible ceiling fans rated
at 1.6 A or less, and fan light kits rated at 300 watts total or
less. Not for use with any other lighting fixtures or electrical
appliances.
2. Not for use with shaded-pole motors. Not recommended
for use with the Hunter Original®. For Hunter Original®
series fans, use Hunter control model numbers 22691,
27189, or 27187.
3. This control requires separate wiring for the
ceiling fan and fan light kit. If one wall switch
currently supplies power to both the fan and
light, additional wiring for the light fixture will
be required to use this Hunter control.
4. MEDIUM and LOW speeds may vary from the
ceiling fans factory-set speeds because of
motor variations.
Installation Instructions:
1. Set the ceiling fans speed to the HIGH
position before installation. Do not change
the ceiling fan‘s speed setting after your speed
control is installed, as damage to your ceiling fan
or Hunter control may result.
2. Verify proper operation of the ceiling fan wall
switch before installation. Improper wiring can
damage the control, and will void the warranty.
3. Disconnect power to ceiling fan at the main
electric panel. Remove fuse or switch circuit
breaker to OFF position.
4. Install in a metal or plastic wallbox. Refer to the
Installation Figure for your Hunter speed control.
Remove wallplate to expose the wiring, and
disconnect the existing switch.
5. If 4 wall wires are visible, connect each black wire
lead to the Hunter speed control’s black wire. If 2
wires are visible, connect each to a Hunter speed
control lead. Use the wire nuts supplied to make
the connections. Refer to the Wiring Diagram,
which shows the proper connections. If a ground
wire is provided in your electrical box, attach
it to the ground screw near the bottom of the
mounting plate.
6. Gently push wires and speed control into switch
box. Attach the Hunter speed control to switch
box with the two screws supplied.
7. Remove the knob from the control shaft. Mount
wallplate over control with existing screws.
8. Replace knob onto control shaft.
Turn knob to the OFF position.
9. Restore power at main electrical
panel.
10. Operate ceiling fan by turning
dial to the desired speed.
For best operation: select HIGH speed
until motor starts, then select desired
speed.
Quiet Fan Control
Clasificaciones: 120 VAC, 1.6 A, 60 Hz
Control Rotatorio Para Ventilador De 3 Velocidades
Modelos: 27180
Lea y guarde estas instrucciones.
Cuidado: !Riesgo de choque eléctrico!
Todo el cableado y conexiones se deben hacer de
acuerdo con los códigos elèctricos nacionales y locales.
Este producto se ajusta al Estándar 1917 UL.
Notas:
1. Sólo para uso con ventiladores de techo con inversión
de rotación, de 1.6 amperios o menos, y con conjuntos
de lámparas de 300 vatios o menos. No debe usarse con
ninguna otra lámpara o aparato eléctrico.
2. No debe usarse con motores de polo sombreado. No se
recomienda su uso con el modelo Hunter Original®. Para los
ventiladores de la serie Hunter Original®, use los controles
Hunter modelos 22691, 27189, o 27187.
3. Este control requiere un cableado separado para el
ventilador de techo y el conjunto de luz del ventilador. Si
un interruptor de pared suministra actualmente energía al
ventilador y la lámpara, se necesitará un cableado adicional
para la lámpara para poder usar este control Hunter.
4. Las velocidades MEDIA y BAJA pueden ser diferentes de
las velocidades jadas en fábrica debido a variaciones del
motor.
Instrucciones de instalación:
1. Coloque el control de velocidad
del ventilador de cielo raso en
la posición de Alta Velocidad
antes de instalar este control. No
cambie el ajuste de velocidad
de su ventilador de cielo luego
de tener instalado el control de
velocidad, puesto que podría dañar
su ventilador de cielo o el control de
Hunter.
2. Verifique que el interruptor de pared del
ventilador trabaja correctamente antes de la
instalación. Las conexiones incorrectas pueden
dañar el control y anularán la garantía.
3. Desconecte la energía eléctrica del ventilador de
cielo raso en el panel elÈctrico principal. Retire
el fusible o coloque el disyuntor en la posición
apagado.
4. Vea la ilustración que muestra la instalación de su
control de velocidad de Hunter. Retire la placa de
la pared para exponer los cables y desconecte el
interruptor existente.
5. Si hay 4 alambres visibles, conecte cada alambre del
control de velocidad Hunter a un alambre negro.
Si hay 2 alambres visibles, conecte cada uno a un
alambre del control de velocidad Hunter. Use las
tuercas de alambres suministradas con el control
para hacer las conexiones. Consulte el Diagrama
de cableado, que muestra la forma correcta de
conectar los alambres. Si su caja eléctrica contiene
un alambre de tierra, conéctelo al tornillo di tierra
ubicado cerca de la placa de montaje inferior.
6. Empuje los alambres y el control de velocidad, con
mucho cuidado, dentro de la caja del interruptor.
Asegure el control de velocidad Hunter a la caja del
interruptor con los dos tornillos suministrados.
7. Retire la perilla del eje de control. Monte la placa de
la pared sobre el control con los tornillos existentes.
8. Coloque nuevamente la perilla sobre el eje de
control y gírelo a la posición apagado.
9. Vuelva a conectar la energÌa eléctrica en el panel el
èctrico principal.
10. Haga funcionar el ventilador de cielo raso haciendo
girar la perilla del control a la velocidad deseada.
Para la mejor operación: seleccione alta velocidad hasta
que el motor arranque y entonces seleccione la velocidad
deseada.
41306 r030415
120v AC
60 Hz
Neutral
Neutro
Green
Verde
Ground
La Tierra
Hot Wire
Alambre de línea
Black
Negro
Black
Negro
Fan
Ventilador
Wiring Diagram
Diagrama de cableado
HUNTER FAN COMPANY CONTROL LIMITED WARRANTY
The Hunter Fan Company makes the following limited
warranty to the original purchaser of the Hunter Control
(“Control”): Your Control is warranted to be free from
defects in material and workmanship for a period of one
year from the date of sale. If the Control malfunctions or
fails within the warranty period due to a defect in material
or workmanship we will replace it free of charge. IF
THE ORIGINAL PURCHASER CEASES TO OWN THE
CONTROL, THIS WARRANTY AND ANY IMPLIED
WARRANTY, INCLUDING BUT NOT LIMITED TO
ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, ARE
VOIDED. THIS WARRANTY IS IN LIEU OF ALL
OTHER EXPRESS WARRANTIES. THE DURATION
OF ANY IMPLIED WARRANTY, INCLUDING, BUT
NOT LIMITED TO, ANY IMPLIED WARRANTY OF
MECHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, IN RESPECT TO ANY CONTROL, IS
EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS
WARRANTY SET FORTH ABOVE FOR SUCH CONTROL.
This warranty excludes malfunctions or failures which
were caused by repairs by persons not authorized by us,
mishandling, improper installation, modications, or damage
to the Control while in your possession, or unreasonable use.
This warranty does not apply to batteries or to deterioration
or damage to the product caused by the use of faulty
batteries. To obtain a replacement, return your Control
postage prepaid along with proof of purchase to Hunter
Fan Company Service Department at 7130 Goodlett Farms
Pkwy, Ste 400 Memphis TN 38016 USA. IN NO EVENT SHALL
HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL
OR INCIDENTAL DAMAGES. SOME STATES DO NOT ALLOW
LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS
OR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS
OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY
GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO
HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Hunter Fan Company
7130 Goodlett Farms Pkwy, Ste 400
Memphis TN 38016 USA

Transcripción de documentos

switch before installation. Improper wiring can damage the control, and will void the warranty. 3. Disconnect power to ceiling fan at the main electric panel. Remove fuse or switch circuit breaker to OFF position. Quiet Fan Control Ratings: 120 VAC, 1.6 A, 60 Hz 3-Speed Rotary Control Model 27180 Read and save these instructions. Caution: Risk of Electrical Shock! All wiring must be performed in accordance with national and local electrical codes. Use only to control a single ceiling fan. This product conforms to UL Standard 1917. Notes: 1. For use only with electrically reversible ceiling fans rated at 1.6 A or less, and fan light kits rated at 300 watts total or less. Not for use with any other lighting fixtures or electrical appliances. 2. Not for use with shaded-pole motors. Not recommended for use with the Hunter Original®. For Hunter Original® series fans, use Hunter control model numbers 22691, 27189, or 27187. 3. This control requires separate wiring for the ceiling fan and fan light kit. If one wall switch currently supplies power to both the fan and light, additional wiring for the light fixture will be required to use this Hunter control. 4. MEDIUM and LOW speeds may vary from the ceiling fan’s factory-set speeds because of motor variations. 4. Install in a metal or plastic wallbox. Refer to the Installation Figure for your Hunter speed control. Remove wallplate to expose the wiring, and disconnect the existing switch. 5. If 4 wall wires are visible, connect each black wire lead to the Hunter speed control’s black wire. If 2 wires are visible, connect each to a Hunter speed control lead. Use the wire nuts supplied to make the connections. Refer to the Wiring Diagram, which shows the proper connections. If a ground wire is provided in your electrical box, attach it to the ground screw near the bottom of the mounting plate. 6. Gently push wires and speed control into switch box. Attach the Hunter speed control to switch box with the two screws supplied. 7. Remove the knob from the control shaft. Mount wallplate over control with existing screws. 8. 9. Restore power at main electrical panel. 10. Operate ceiling fan by turning dial to the desired speed. For best operation: select HIGH speed until motor starts, then select desired speed. Installation Instructions: 1. Set the ceiling fan’s speed to the HIGH position before installation. Do not change the ceiling fan‘s speed setting after your speed control is installed, as damage to your ceiling fan or Hunter control may result. Replace knob onto control shaft. Turn knob to the OFF position. Hot Wire Alambre de línea Black Negro 2. Verify proper operation of the ceiling fan wall Black Negro 120v AC 60 Hz Neutral Neutro Hunter Fan Company 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA 41306 r030415 Ground La Tierra Green Verde Fan Ventilador Wiring Diagram Diagrama de cableado Quiet Fan Control Clasificaciones: 120 VAC, 1.6 A, 60 Hz Control Rotatorio Para Ventilador De 3 Velocidades Modelos: 27180 Lea y guarde estas instrucciones. Cuidado: !Riesgo de choque eléctrico! Todo el cableado y conexiones se deben hacer de acuerdo con los códigos elèctricos nacionales y locales. Este producto se ajusta al Estándar 1917 UL. Notas: 1. Sólo para uso con ventiladores de techo con inversión de rotación, de 1.6 amperios o menos, y con conjuntos de lámparas de 300 vatios o menos. No debe usarse con ninguna otra lámpara o aparato eléctrico. 2. No debe usarse con motores de polo sombreado. No se recomienda su uso con el modelo Hunter Original®. Para los ventiladores de la serie Hunter Original®, use los controles Hunter modelos 22691, 27189, o 27187. 3. Este control requiere un cableado separado para el ventilador de techo y el conjunto de luz del ventilador. Si un interruptor de pared suministra actualmente energía al ventilador y la lámpara, se necesitará un cableado adicional para la lámpara para poder usar este control Hunter. 4. Las velocidades MEDIA y BAJA pueden ser diferentes de las velocidades fijadas en fábrica debido a variaciones del motor. Instrucciones de instalación: 1. Coloque el control de velocidad del ventilador de cielo raso en la posición de Alta Velocidad antes de instalar este control. No cambie el ajuste de velocidad de su ventilador de cielo luego de tener instalado el control de velocidad, puesto que podría dañar su ventilador de cielo o el control de Hunter. 2. Verifique que el interruptor de pared del ventilador trabaja correctamente antes de la instalación. Las conexiones incorrectas pueden dañar el control y anularán la garantía. 3. Desconecte la energía eléctrica del ventilador de cielo raso en el panel elÈctrico principal. Retire el fusible o coloque el disyuntor en la posición apagado. 4. Vea la ilustración que muestra la instalación de su control de velocidad de Hunter. Retire la placa de la pared para exponer los cables y desconecte el interruptor existente. 5. Si hay 4 alambres visibles, conecte cada alambre del control de velocidad Hunter a un alambre negro. Si hay 2 alambres visibles, conecte cada uno a un alambre del control de velocidad Hunter. Use las tuercas de alambres suministradas con el control para hacer las conexiones. Consulte el Diagrama de cableado, que muestra la forma correcta de conectar los alambres. Si su caja eléctrica contiene un alambre de tierra, conéctelo al tornillo di tierra ubicado cerca de la placa de montaje inferior. 6. Empuje los alambres y el control de velocidad, con mucho cuidado, dentro de la caja del interruptor. Asegure el control de velocidad Hunter a la caja del interruptor con los dos tornillos suministrados. 7. Retire la perilla del eje de control. Monte la placa de la pared sobre el control con los tornillos existentes. 8. Coloque nuevamente la perilla sobre el eje de control y gírelo a la posición apagado. 9. Vuelva a conectar la energÌa eléctrica en el panel el èctrico principal. 10. Haga funcionar el ventilador de cielo raso haciendo girar la perilla del control a la velocidad deseada. Para la mejor operación: seleccione alta velocidad hasta que el motor arranque y entonces seleccione la velocidad deseada. HUNTER FAN COMPANY CONTROL LIMITED WARRANTY The Hunter Fan Company makes the following limited warranty to the original purchaser of the Hunter Control (“Control”): Your Control is warranted to be free from defects in material and workmanship for a period of one year from the date of sale. If the Control malfunctions or fails within the warranty period due to a defect in material or workmanship we will replace it free of charge. IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL, THIS WARRANTY AND ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MECHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY CONTROL, IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH CONTROL. This warranty excludes malfunctions or failures which were caused by repairs by persons not authorized by us, mishandling, improper installation, modifications, or damage to the Control while in your possession, or unreasonable use. This warranty does not apply to batteries or to deterioration or damage to the product caused by the use of faulty batteries. To obtain a replacement, return your Control postage prepaid along with proof of purchase to Hunter Fan Company Service Department at 7130 Goodlett Farms Pkwy, Ste 400 Memphis TN 38016 USA. IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
  • Page 1 1

Hunter Fan 27180 El manual del propietario

Tipo
El manual del propietario

En otros idiomas