Panasonic KXHNS103 Instrucciones de operación

Tipo
Instrucciones de operación
Installation Guide
Home Network System
Water Leak Sensor
Model No. KX-HNS103
Thank you for purchasing a Panasonic product.
This document explains how to install the water leak sensor properly.
For details about how to use the system, refer to the User’s Guide
(page 18).
Please read this document before using the unit and save it for future
reference. For assistance, please contact us at 1-800-272-7033 or visit
our
Web site: http://shop.panasonic.com/support for customers in the
U.S.A.
Please register your product: http://shop.panasonic.com/support
In order to use this device:
R Download the latest version of the [Home Network] app.
R Update your hub to the latest firmware version
(version 5.00 or later).
For more information, refer to the User’s Guide (page 18).
Printed in China
HNS103_(en_en)_0119_ver.101.pdf 1 2017/01/25 14:57:29
Introduction
Accessory information ...............3
Important Information
About this system ......................4
For your safety ...........................
4
Important safety instructions ......5
For best performance ................5
Other information .......................6
Setup
Part names and functions ..........8
LED indicator .............................8
Setup overview ..........................8
Inserting the battery ...................9
Registering the sensor ...............9
Confirming the usage area ......10
Installation ...............................11
Appendix
Testing the sensor ...................18
Features available when using the
[Home Network] app ................18
Accessing the User’s Guide ....18
Specifications ..........................19
FCC and other information ......20
Customer services ...................21
Limited Warranty (ONLY FOR
U.S.A.) .....................................22
2
Table of Contents
HNS103_(en_en)_0119_ver.101.pdf 2 2017/01/25 14:57:40
Accessory information
Supplied accessories
No. Accessory item/Part number Quantity
A
Battery
*
1
1
B
Wall mounting adaptors
*
2
2
C
Wall mounting screws (25 mm (1 inch))
*
3
/XTB4+25AVW
3
*1 When replacing the battery, see “Power source” of “Specifications”, page 19
f
or battery information.
*2 1 adaptor for the main unit: PNHR2107Z
1 adaptor for the probe unit: PNHR2108Z
*3 2 screws for the main unit and 1 screw for the probe unit
A
B C
Other information
R D
esign and specifications are subject to change without notice.
R The illustrations in these instructions may vary slightly from the actual product.
Trademarks
R i
Phone and iPad are registered trademarks of Apple Inc.
R Android is a trademark of Google Inc.
R Microsoft, Windows, and Internet Explorer are either registered trademarks or
trademarks of Microsoft Corporation in the United States and/or other countries.
R All other trademarks identified herein are the property of their respective owners.
For assistance, please visit http://shop.panasonic.com/support
3
Introduction
HNS103_(en_en)_0119_ver.101.pdf 3 2017/01/25 14:57:41
About this system
R This system is an auxiliary system; it
is not designed to provide complete
protection from property loss.
Panasonic will not be held
responsible in the event that
property loss occurs while this
system is in operation.
R The system’s wireless features are
subject to interference, therefore
functionality in all situations cannot
be guaranteed. Panasonic will not
be held responsible for injury or
damage to property that occurs in
the event of wireless communication
error or failure.
For your safety
T
o prevent severe injury and loss of life/
property, read this section carefully
before using the product to ensure
proper and safe operation of your
product.
WARNING
Power connection
R U
se only the power source marked
on the product.
R Do not connect non-specified
devices.
Installation
R T
o prevent the risk of fire or
electrical shock, do not expose the
product to rain.
R Do not place or use this product
near automatically controlled
devices such as automatic doors
and fire alarms. Radio waves
e
mitted from this product may cause
such devices to malfunction
resulting in an accident.
R Do not allow the cable to be
excessively pulled, bent or placed
under heavy objects. Keep the main
unit upright at all times.
R Do not allow the probe unit to make
contact with a battery or an electric
outlet. The product could become
damaged.
R Keep small parts (screws, etc.) out
of the reach of children. There is a
risk of swallowing. In the event they
are swallowed, seek medical advice
immediately.
Operating safeguards
R D
o not disassemble the product.
Medical
R Consult the manufacturer of any
personal medical devices, such as
pacemakers or hearing aids, to
determine if they are adequately
shielded from external RF (radio
frequency) energy. DECT features
operate between 1.92 GHz and
1.93 GHz with a peak transmission
power of 115 mW.
R Do not use the product in health
care facilities if any regulations
posted in the area instruct you not to
do so. Hospitals or health care
facilities may be using equipment
that could be sensitive to external
RF energy.
CR Lithium battery
R D
o not recharge, disassemble,
remodel, heat or throw it into fire.
4
For a
ssistance, please visit http://shop.panasonic.com/support
Important Information
HNS103_(en_en)_0119_ver.101.pdf 4 2017/01/25 14:57:41
R D
o not touch the terminals
and
with metal objects.
R R
isk of explosion if battery is
replaced by an incorrect type.
Dispose of used battery according to
local regulations.
R If any electrolyte should come into
contact with your hands or clothes,
wash it off thoroughly with water.
R If any electrolyte should come into
contact with your eyes, never rub
your eyes. Rinse your eyes
thoroughly with water, and then
consult a doctor.
CAUTION
CR Lithium battery
R U
se only the battery noted on
page 3.
R Insert the battery correctly.
R Do not leave the battery in an
automobile exposed to direct
sunlight for a long period of time with
the doors and windows closed.
R Remove the battery if you do not
use the product for a long period of
time. Keep it in a cool, dark area.
R Do not replace a battery with wet
hands.
R Keep out of the reach of small
children. There is a risk of
swallowing. If the battery is
swallowed, seek medical attention
immediately.
R Remove the battery if it becomes
unusable. There is a risk of leakage,
overheating, and rupture. Do not
attempt to use a battery if it is
leaking.
R Exercise care when handling the
batteries. Do not allow conductive
materials such as rings, bracelets, or
keys to touch the batteries,
otherwise a short circuit may cause
t
he batteries and/or the conductive
material to overheat and cause
burns.
Important safety
i
nstructions
When using your product, basic safety
precautions should always be followed
to reduce the risk of fire, electric shock,
and injury to persons, including the
following:
1. Use only the batteries indicated in
this document. Do not dispose of
batteries in a fire. They may
explode. Check with local codes for
possible special disposal
instructions.
SAVE THESE INSTRUCTIONS
For b
est performance
Hub location/avoiding noise
T
he hub and other compatible
Panasonic devices use radio waves to
communicate with each other.
R For maximum coverage and
noise-free communications, place
your hub:
at a convenient, high, and central
location with no obstructions
between the product and hub in
an indoor environment.
away from electronic appliances
such as TVs, radios, personal
computers, wireless devices, or
other phones.
facing away from radio frequency
transmitters, such as external
For a
ssistance, please visit http://shop.panasonic.com/support
5
Important Information
HNS103_(en_en)_0119_ver.101.pdf 5 2017/01/25 14:57:41
antennas of mobile phone cell
s
tations. (Avoid putting the hub
on a bay window or near a
window.)
R If the reception for a hub location is
not satisfactory, move the hub to
another location for better reception.
Environment
R K
eep the product away from
electrical noise generating devices,
such as fluorescent lamps and
motors.
R The product should be kept free
from excessive smoke, dust, high
temperature, and vibration.
R The product should not be exposed
to direct sunlight.
R Do not place heavy objects on top of
the product.
R The product should be kept away
from heat sources such as heaters,
kitchen stoves, etc. It should not be
placed in rooms where the
temperature is less than 0 °C (32 °F)
or greater than 40 °C (104 °F).
R Operating the product near electrical
appliances may cause interference.
Move away from the electrical
appliances.
R Do not allow the probe unit’s metal
probes to make contact with metal
objects. This may reduce the battery
life.
Other information
C
AUTION: Risk of explosion if battery
is replaced by an incorrect type.
Dispose of used batteries according to
the instructions.
Routine care
R Wipe the outer surface of the
product with a soft moist cloth.
R Do not use benzine, thinner, or any
abrasive powder.
R If the probe unit’s metal probes
come into contact with a foreign
material (oil, detergent, etc.), the
probes may repel water and
therefore will not be able to properly
detect a water leak. Periodically
check the metal probes and wipe
away any water or foreign material
that has become adhered to the
probes.
R If the probes come into contact with
water, wipe the probe unit dry. Do
not allow the probes to remain in
contact with water for an extended
period of time, as the probes may
begin to turn black. (This will not
affect the product’s ability to detect a
water leak.)
Information on Disposal in other
C
ountries outside the European
Union
These symbols are only valid in the
E
uropean Union. If you wish to discard
these items, please contact your local
authorities or dealer and ask for the
correct method of disposal.
6
For a
ssistance, please visit http://shop.panasonic.com/support
Important Information
HNS103_(en_en)_0119_ver.101.pdf 6 2017/01/25 14:57:41
Note for the battery removal
procedure
Refer to “Inserting the battery” on
page 9.
Notice
For a
ssistance, please visit http://shop.panasonic.com/support
7
Important Information
HNS103_(en_en)_0119_ver.101.pdf 7 2017/01/25 14:57:41
Part names and
functions
C
D
A
B
E
F
G
Main unit
Main unit cover
M N
U
sed to confirm the status of the
sensor or register the sensor to
the hub.
LED indicator
Cable
Probe unit
Probes
LED indicator
Y
ou can press M
N
and check the
LED indicator to confirm the sensor’s
status.
After confirming the sensor’s status, we
recommend turning the LED indicator
off by pressing M N
again as soon
as possible, otherwise battery life may
be reduced.
Indicator Status
Green, lit No water detected
Red, lit Water detected
Red,
b
linking
Sensor is out of range
of the hub
Green,
b
linking
slowly
Registration mode
(You pressed and held
M
N)
Off No battery power
Note:
R The LED indicator does not indicate
sensor status if the sensor has not
been registered (page 9).
Setup overview
1 I
nitial setup
Make sure you can access the
system using your mobile device.
For details, refer to the System
Setup Guide included with your
hub.
2 Insert the battery
The sensor is battery powered.
3 Registration
Required only if the sensor was
purchased separately (i.e., not as
part of a bundle).
4 Confirm the usage area
Read the information in this
document to confirm that the
desired installation area is suitable
to proper operation.
5 Installation
Install the sensor in the desired
location.
8
For a
ssistance, please visit http://shop.panasonic.com/support
Setup
HNS103_(en_en)_0119_ver.101.pdf 8 2017/01/25 14:57:41
Inserting the battery
R USE ONLY a CR2 Lithium battery.
R Confirm the polarities (
, ).
1 R
emove the main unit cover.
R Lift from the indented area (A)
and open the main unit cover
(B).
1
2
2 I
nsert the battery.
3 A
ttach the main unit cover.
Registering the
sensor
This procedure is not required for
d
evices that were included as part of
a bundle.
Before you can use the sensor, it must
be registered to the hub.
If you purchased devices separately
(i.e., not as part of a bundle), you must
register each device to the hub.
You can register each device by using
the registration buttons or the [Home
Network] app.
Using registration buttons
1 H
ub:
Press and hold M
OTHER
D
EVICEN until the LED indicator
blinks slowly in green.
2 Sensor:
Remove the main unit cover and
press and hold M
N
until the
LED indicator blinks slowly in
green (page 8).
R When registration is complete,
the hub sounds one long beep.
Note:
R To cancel without registering the
sensor, press M
N on the hub and
on the sensor again.
R If registration fails, the hub sounds
several short beeps.
Using the app
W
hen you register the sensor by using
the [Home Network] app, you can
assign a name to your devices and
For assistance, please visit http://shop.panasonic.com/support
9
Setup
HNS103_(en_en)_0119_ver.101.pdf 9 2017/01/25 14:57:41
group them by location. For more
i
nformation, refer to the User’s Guide
(page 18).
Confirming the
u
sage area
Wireless communication
r
ange
The wireless communication range of
each device in the system from the hub
is approximately 50 m (160 feet)
indoors and approximately 300 m
(1,000 feet) outdoors. Wireless
communication may be unreliable
when the following obstacles are
located between the hub and other
devices.
R Metal doors or screens
R Walls containing aluminum-sheet
insulation
R Walls made of concrete or
corrugated iron
R Double-pane glass windows
R Multiple walls
R When using each device on
separate floors or in different
buildings
Note:
R You can check the sensor’s
communication status by pressing
M
N.
If the LED indicator is lit in
green or red, the sensor is
communicating properly with the
hub. If the LED indicator blinks in
red, it is out of range of the hub.
10
For a
ssistance, please visit http://shop.panasonic.com/support
Setup
HNS103_(en_en)_0119_ver.101.pdf 10 2017/01/25 14:57:41
Installation
The main unit is installed on a wall, and the probe unit can be installed on a wall or
a floor.
When the metal probes on the probe unit come in to contact with water, a small
amount of electrical charge flows between the probes, which the main unit
recognizes as a water leak.
Probe unit installed on wall Probe unit installed on floor
Installation precautions
R T
he sensor is not designed to be used in situations that require high reliability.
We do not recommend use of the sensor in these situations.
R Panasonic takes no responsibility for any injury or damage caused by the use of
this product.
R When installing, make sure the battery is inserted properly and the main unit
cover is completely closed.
R When installing on a wooden surface, use the included wall mounting adaptors.
Secure the wall mounting adaptors to the wall using screws (not double-sided
tape).
R Mount the sensor on the stable location where the sensor can be adequately
supported when mounting.
R Do not mount the sensor on a soft material. It may fall down, break or cause
injury.
R Do not mount the sensor on the following places: gypsum board, ALC
(autoclaved lightweight cellular concrete), concrete block, plywood less than
25.4 mm (1 inch) thick, etc.
R The sensor may not be able to properly detect a water leak if the water contains
contaminants such as oil, or if the water is frozen (i.e., ice or snow).
For a
ssistance, please visit http://shop.panasonic.com/support
11
Setup
HNS103_(en_en)_0119_ver.101.pdf 11 2017/01/25 14:57:41
R I
nstall the probe unit so that the metal probes are horizontal. A water leak can
only be detected if water touches both of the metal probes; if water touches only
one of the probes, a water leak will not be detected.
Correct installation Incorrect installation
Metal probes are horizontal to the
f
loor
Metal probes are not horizontal to
t
he floor
Installation location
I
nstall the water leak sensor in a basement, kitchen, utility room, or anywhere you
want to detect a water leak. Common installation examples include near a washing
machine, hot water heater, or a location where a water leak has occurred in the
past.
Note:
R Install the probe unit so that its metal probes are about 1 mm (1/32 inches)
above the floor. If the probes touch the floor, the sensor may make false
detections. If the probes are too far from the floor, water leaks can only be
detected after the leaked water has become deep enough to touch the probes.
R Install the main unit 1 m (3 feet 3 inches) or higher above the floor. The main
unit is not waterproof; if it becomes wet, the sensor may become damaged and
water leaks will not be detected properly.
12
For a
ssistance, please visit http://shop.panasonic.com/support
Setup
HNS103_(en_en)_0119_ver.101.pdf 12 2017/01/25 14:57:41
Securing with the wall mounting adaptors
1 Use screws to attach the wall mounting adaptors to the wall.
n Main unit
1
Screws
2
75 mm (2 15/16 inches)
n Probe unit
1
Screw
2
1
1
1
Note:
R T
o install the probe unit on a floor, see page 16. In this case, you will not
use the probe unit’s wall mounting adaptor.
For assistance, please visit http://shop.panasonic.com/support
13
Setup
HNS103_(en_en)_0119_ver.101.pdf 13 2017/01/25 14:57:41
2 R
emove the backing from the double-sided tape, insert the main unit and the
probe unit into the wall mounting adaptors, and then press firmly on each unit
to ensure solid adhesion to the installation surface.
3
Double-sided tape
3
3
3
14
For a
ssistance, please visit http://shop.panasonic.com/support
Setup
HNS103_(en_en)_0119_ver.101.pdf 14 2017/01/25 14:57:41
Securing with double-sided tape only
Note:
R Make sure any surfaces that will make contact with the double-sided tape are
clean and dry before applying the tape. When attaching the double-sided tape to
concrete or bricks, if the surface of the concrete or bricks is wet, make sure to
completely dry the surface before attaching the double-sided tape.
1 Remove the backing from the double-sided tape, attach the main unit and the
probe unit to the installation surface, and then press firmly on each unit to
ensure solid adhesion to the installation surface.
1
Double-sided tape
1
1
1
Note:
R T
o install the probe unit on a floor, see page 16.
For assistance, please visit http://shop.panasonic.com/support
15
Setup
HNS103_(en_en)_0119_ver.101.pdf 15 2017/01/25 14:57:41
Installing the probe unit on a floor
When installing the probe unit on a floor, use the double-sided tape to attach the
probe unit directly to the floor.
Note:
R If the probe unit is inserted into the wall mounting adaptor and attached to a
floor, the probes will be too far from the floor and therefore water leaks can only
be detected after the leaked water has become deep enough to touch the
probes.
Correct installation Incorrect installation
Shallow water touches probes Only deep water can touch probes
A
A
Wall mounting adaptor
16
For a
ssistance, please visit http://shop.panasonic.com/support
Setup
HNS103_(en_en)_0119_ver.101.pdf 16 2017/01/25 14:57:41
Removing from the wall
n Removing from the wall mounting adaptors
1 Insert a flat screwdriver into the notches on the wall mounting adaptors, and
carefully pry away the main unit and probe unit.
2 R
emove the screws that secure the wall mounting adaptors to the wall.
n Removing when secured with double-sided tape only
1 Tie a piece of thread to two sticks, screwdrivers, etc.
2 Pull the thread tight and use it to cut the double-sided tape, and then remove
any excess tape.
1
Excess tape
For a
ssistance, please visit http://shop.panasonic.com/support
17
Setup
HNS103_(en_en)_0119_ver.101.pdf 17 2017/01/25 14:57:41
Testing the sensor
You can check the sensor’s LED
indicator and test the performance of
the sensor.
1 Remove the main unit cover.
2 Press M N.
3 T
ouch the probes of the probe unit
to water.
4 Confirm that the LED indicator
lights in red.
5 Press M
N
again.
Features available
w
hen using the
[Home Network] app
Some of the sensor’s features that are
available when using the [Home
Network] app are listed below. For
more information, refer to the User’s
Guide (page 18).
Alarm system
You can use the app to arm and
disarm the alarm system, confirm
the current status of the sensor, and
view a log of previous events.
Sensor integration
You can configure the sensor to
trigger other system events, such as
camera recording, turning on an
electric device (such as a lamp), etc.
(Appropriate device required.)
Telephone alert
You can configure the system to call
a preprogrammed phone number
when the sensor is triggered.
Accessing the User’s
Guide
The User’s Guide is a collection of
online documentation that helps you
get the most out of the [Home
Network] app.
1 iPhone
®
/iPad
®
Tap in the app’s home screen.
A
ndroid
devices
Tap
or press your mobile
d
evice’s menu button in the app’s
home screen.
2 Tap [User’s Guide].
Note:
R Microsoft
®
Windows
®
Internet
Explorer
®
8 and earlier versions are
not supported.
R Android 4.1 or later versions are
recommended.
R You can also access the User’s
Guide at the web page listed below.
www.panasonic.net/pcc/support/tel/
homenetwork/manual/
18
For a
ssistance, please visit http://shop.panasonic.com/support
Appendix
HNS103_(en_en)_0119_ver.101.pdf 18 2017/01/25 14:57:41
Specifications
R Standards
DECT (Digital Enhanced Cordless
Telecommunications)
R Frequency range
DECT: 1.92 GHz – 1.93 GHz
R RF transmission power
DECT: 115 mW (max.)
R Power source
Lithium battery CR2 (CR15H270)
(1 ´ 3.0 V, 850 mAh)
R Operating conditions
0 °C – 40 °C (32 °F – 104 °F)
R Battery life
Up to 2 years (when the sensor is
triggered once a month, in an
environment of 25 °C) when using a
3.0 V, 850 mAh battery. The battery
life differs depending on the capacity
of the battery used.
R Dimensions
Main unit (height ´ width ´ depth)
(not including double-sided tape):
Approx. 106 mm ´ 31 mm ´ 22 mm
(4 5/32 inches ´ 1 7/32 inches ´
7/8 inches)
Probe unit (height ´ width ´
depth) (not including
double-sided tape):
Approx. 44 mm ´ 24 mm ´ 10 mm
(1 23/32 inches ´ 15/16 inches ´
3/8 inches)
Cable (length):
Approx. 1.2 m (3 feet 11 inches)
R Mass (weight)
Approx. 80 g (0.18 lb), excluding the
battery
For a
ssistance, please visit http://shop.panasonic.com/support
19
Appendix
HNS103_(en_en)_0119_ver.101.pdf 19 2017/01/25 14:57:41
FCC and other
information
This device complies with Part 15 of
the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful
interference, and (2) this device must
accept any interference received,
including interference that may cause
undesired operation.
Privacy of communications may not be
ensured when using this device.
CAUTION:
Any changes or modifications not
expressly approved by the party
responsible for compliance could void
the user’s authority to operate this
device.
NOTE:
This equipment has been tested and
found to comply with the limits for a
Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are
designed to provide reasonable
protection against harmful interference
in a residential installation. This
equipment generates, uses, and can
radiate radio frequency energy and, if
not installed and used in accordance
with the instructions, may cause
harmful interference to radio
communications. However, there is no
guarantee that interference will not
occur in a particular installation. If this
equipment does cause harmful
interference to radio or television
reception, which can be determined by
turning the equipment off and on, the
user is encouraged to try to correct the
interference by one or more of the
f
ollowing measures:
Reorient or relocate the receiving
antenna.
Increase the separation between the
equipment and receiver.
Connect the equipment into an
outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an
experienced radio/TV technician for
help.
Some devices operate at frequencies
that may cause interference to nearby
TVs and VCRs. To minimize or prevent
such interference, this device should
not be placed near or on top of a TV or
VCR. If interference is experienced,
move this device further away from the
TV or VCR. This will often reduce or
eliminate interference.
FCC RF Exposure Warning:
R This product complies with FCC
radiation exposure limits set forth for
an uncontrolled environment.
R To comply with FCC RF exposure
requirements, the device must be
installed and operated 20 cm
(8 inches) or more between the
product and all person’s body.
R This product may not be collocated
or operated in conjunction with any
other antenna or transmitter.
R For body-worn operation, the device
must be used only with a
non-metallic accessory. Use of other
accessories may not ensure
compliance with FCC RF exposure
requirements.
Notice:
R FCC ID can be found inside the
main unit.
20
For a
ssistance, please visit http://shop.panasonic.com/support
Appendix
HNS103_(en_en)_0119_ver.101.pdf 20 2017/01/25 14:57:41
Customer services
You may also contact us directly at: 1-800-272-7033,
Monday - Friday 9 am to 9 pm;
Saturday - Sunday 10 am to 7 pm, EST.
Accessories!
http://shop.panasonic.com/support
Customer Services Directory
Shop
for all your Panasonic gear
Go to
Get everything you need to get the most out of
your Panasonic products
Accessories & Parts for your Camera, Phone, A/V
products, TV, Computers & Networking, Personal
Care, Home Appliances, Headphones, Ba!eries,
Backup Chargers & more…
For Product Informa"on, Opera"ng Assistance,
Parts, Owner’s Manuals, Dealer and Service info
go to http://shop.panasonic.com/support
For the hearing or speech impaired TTY: 1- 877-833-8855
As of June 2015
For a
ssistance, please visit http://shop.panasonic.com/support
21
Appendix
HNS103_(en_en)_0119_ver.101.pdf 21 2017/01/25 14:57:41
Limited Warranty (ONLY FOR U.S.A.)
Limited Warranty Coverage (For USA Only)
Labor
One (1) Year
Parts
One (1) Year
To submit a new repair request and for quick repair status visit our Web Site at
http://shop.panasonic.com/support
Panasonic Products Limited Warranty
Online Repair Request
Mail-In Service--Online Repair Request
If your product does not work properly because of a defect in materials or workmanship,
Panasonic Corporation of North America (referred to as “the warrantor”) will, for the length
of the period indicated on the chart below, which starts with the date of original purchase
(“warranty period”), at its option either (a) repair your product with new or refurbished parts,
(b) replace it with a new or a refurbished equivalent value product, or (c) refund your
purchase price. The decision to repair, replace or refund will be made by the warrantor.
During the “Labor” warranty period there will be no charge for labor. During the “Parts”
warranty period, there will be no charge for parts. This Limited Warranty excludes both
parts and labor for non-rechargeable batteries, antennas, and cosmetic parts (cabinet).
This warranty only applies to products purchased and serviced in the United States.
This warranty is extended only to the original purchaser of a new product which was
not sold “as is”.
Home Network System Products
microSD card (Included model only)
90 days N/A
When shipping the unit, carefully pack, include all supplied accessories listed in the
Owner’s Manual, and send it prepaid, adequately insured and packed well in a carton box.
When shipping Lithium Ion batteries please visit our Web Site at
http://shop.panasonic.com/support as Panasonic is committed to providing the most up to
date information. Include a letter detailing the complaint, a return address and provide a
daytime phone number where you can be reached. A valid registered receipt is required
under the Limited Warranty.
IF REPAIR IS NEEDED DURING THE WARRANTY PERIOD, THE PURCHASER WILL
BE REQUIRED TO FURNISH A SALES RECEIPT/PROOF OF PURCHASE INDICATING
DATE OF PURCHASE, AMOUNT PAID AND PLACE OF PURCHASE. CUSTOMER WILL
BE CHARGED FOR THE REPAIR OF ANY UNIT RECEIVED WITHOUT SUCH PROOF
OF PURCHASE.
Product or Part Name
22
For a
ssistance, please visit http://shop.panasonic.com/support
Appendix
HNS103_(en_en)_0119_ver.101.pdf 22 2017/01/25 14:57:41
Limited Warranty Limits and Exclusions
(As examples, this excludes damages for lost time, travel to and from the servicer,
loss of or damage to media or images, data or other memory or recorded content.
The items listed are not exclusive, but for illustration only.)
This warranty ONLY COVERS failures due to defects in materials or workmanship,
and DOES NOT COVER normal wear and tear or cosmetic damage. The warranty
ALSO DOES NOT COVER damages which occurred in shipment, or failures which
are caused by products not supplied by the warrantor, or failures which result from
accidents, misuse, abuse, neglect, mishandling, misapplication, alteration, faulty
installation, set-up adjustments, misadjustment of consumer controls, improper
maintenance, power line surge, lightning damage, modification, introduction of sand,
humidity or liquids, commercial use such as hotel, office, restaurant, or other business
or rental use of the product, or service by anyone other than a Factory Service Center
or other Authorized Servicer, or damage that is attributable to acts of God.
THERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED UNDER
“LIMITED WARRANTY COVERAGE”.
THE WARRANTOR IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING FROM THE USE OF THIS PRODUCT, OR ARISING OUT
OF ANY BREACH OF THIS WARRANTY.
ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF
MERCHANTABILITY, ARE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY.
PARTS AND SERVICE, WHICH ARE NOT COVERED BY THIS LIMITED WARRANTY,
ARE YOUR RESPONSIBILITY.
Some states do not allow the exclusion or limitation of incidental or consequential damages,
or limitations on how long an implied warranty lasts, so the exclusions may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary
from state to state. If a problem with this product develops during or after the warranty period,
you may contact your dealer or Service Center. If the problem is not handled to your
satisfaction, then write to:
Consumer Affairs Department
Panasonic Corporation of North America
661 Independence Pkwy
Chesapeake, VA 23320
As of June 2015
For a
ssistance, please visit http://shop.panasonic.com/support
23
Appendix
HNS103_(en_en)_0119_ver.101.pdf 23 2017/01/25 14:57:41
1 Use CR2 Lithium battery.
2
Use the Home Network app to access the Users Guide
and refer to the Troubleshooting section.
IMPORTANT!
If your product is not working properly. . .
Visit our Web site: http://shop.panasonic.com/support
LFAQ and troubleshooting hints are available.
For your future reference
W
e recommend keeping a record of the following information to assist
with any repair under warranty.
Serial No. Date of purchase
(found inside the main unit)
N
ame and address of dealer
Attach your purchase receipt here.
Two Riverfront Plaza, Newark, NJ 07102-5490
© Panasonic Corporation 2015
HNS103_(en_en)_0119_ver.101.pdf 24 2017/01/25 14:57:41
Guía de instalación
Sistema de red doméstico
Sensor de pérdida de agua
Modelo n° KX-HNS103
Gracias por adquirir un producto Panasonic.
Este documento explica cómo instalar el sensor de fuga de agua de forma
correcta.
Para obtener detalles sobre cómo usar el sistema, consulte la Guía del usua-
rio (página 13).
Lea este documento antes de usar la unidad, y guárdelo para consultarlo en el
futuro. Para obtener ayuda, comuníquese con nosotros llamando al
1-800-272-7033 o visite nuestro sitio web: http://shop.panasonic.com/support
para clientes en los EE. UU. (solo en inglés)
Por favor, registre su producto: http://shop.panasonic.com/support
Para utilizar este dispositivo:
R Descargue la versión más reciente de la aplicación [Home Network].
R Actualice el hub a la versión de firmware más reciente (versión 5.00 o
posterior). Para obtener más información, consulte la Guía del usuario
(página 13).
PNQX7269YA CC0215WK1126 (E)
HNS103_(es_es)_0202_ver.101.pdf 1 2017/02/02 15:38:21
Configuración
Nombres de los componentes y
funciones .........................................3
Led indicador ...................................3
Resumen de configuración ..............3
Insertar la batería ............................4
Registro del sensor ..........................4
Confirmación del área de uso ..........5
Instalación .......................................6
Apéndice
Prueba del sensor .........................13
Acceso a la Guía del usuario .........13
2
Tabla de Contenido
HNS103_(es_es)_0202_ver.101.pdf 2 2017/02/02 15:38:21
Nombres de los
componentes y
funciones
C
D
A
B
E
F
G
Unidad principal
Tapa de la unidad principal
M N
Se usa para confirmar el estado del
sensor o para registrar el sensor en el
hub.
Led indicador
Cable
Unidad de sonda
Sondas
Led indicador
Puede oprimir M
N y verificar el Led
indicador para confirmar el estado del
sensor.
Tras confirmar el estado del sensor,
recomendamos apagar el Led indicador
volviendo a pulsar M N lo antes posible,
ya que de lo contrario la vida útil de la
batería podría reducirse.
Indicador Estado
Verde, en-
cendido
No se detectó agua
Rojo, encen-
dido
Se detectó agua
Rojo, parpa-
deante
El sensor está fuera de al-
cance del hub
Verde, par-
padeando
lentamente
Modo de registro (Opri-
mió y mantuvo oprimido
M
N)
Apagado Sin batería
Nota:
R El Led indicador no indica el estado del
sensor si el sensor no se ha registrado
(página 4).
Resumen de
configuración
1 Configuración inicial
Asegúrese de poder acceder al
sistema mediante su dispositivo móvil.
Para obtener más detalles, consulte la
Guía de configuración del sistema que
viene con su hub.
2 Inserte la batería
El sensor usa batería.
3 Registro
Solo se requiere si se compró el
sensor por separado (es decir, no
como parte de un paquete).
4 Confirmación del área de uso
Lea la información de este
documento
para confirmar que el área de
Para obtener ayuda, visite http://shop.panasonic.com/support
3
Configuración
HNS103_(es_es)_0202_ver.101.pdf 3 2017/02/02 15:38:21
instalación deseada sea la adecuada
para el correcto funcionamiento.
5 Instalación
Instale el sensor en la ubicación
deseada.
Insertar la batería
R USE SOLO baterías de litio CR2.
R Verifique las polaridades (
, ).
1 Quite la tapa de la unidad principal.
R Levante por el área indicada (A) y
abra la tapa de la unidad principal
(B).
1
2
2 Inserte la batería.
3 Coloque la tapa de la unidad principal.
Registro del sensor
Este procedimiento no es necesario para
unidades que son parte de un paquete.
Antes de poder usar el sensor, debe
registrarlo en el hub.
Si compró los dispositivos por separado (es
decir, no como parte de un paquete), debe
registrar cada dispositivo en el hub.
Puede registrar cada unidad mediante los
botones de registro o la aplicación [Home
Network].
Uso de los botones de registro
1 Hub:
Oprima y mantenga oprimido M
OTHER DEVICEN hasta que el Led
indicador parpadee lentamente en
verde.
2 Sensor:
Quite la tapa de la unidad principal y
mantenga oprimido M
N hasta que
el Led indicador parpadee lentamente
en verde (página 3).
R Cuando se ha completado el
registro, el hub emitirá un pitido
largo.
Nota:
R Para cancelar sin registrar el sensor,
oprima M
N en el hub y en el sensor
nuevamente.
R Si el registro falla, el hub emitirá varios
pitidos cortos.
Uso de la aplicación
Cuando registra el sensor con la aplicación
[Home Network], puede asignarle un
nombre a sus dispositivos y agruparlos por
4
Para obtener ayuda, visite http://shop.panasonic.com/support
Configuración
HNS103_(es_es)_0202_ver.101.pdf 4 2017/02/02 15:38:21
ubicación. Para obtener más información,
consulte la Guía del usuario (página 13).
Confirmación del área
de uso
Alcance de la comunicación
inalámbrica
El alcance de la comunicación inalámbrica
de cada dispositivo en el sistema del hub
es de aproximadamente 50 m (160 pies) en
interiores y de aproximadamente 300 m
(1,000 pies) en el exterior. Es posible que la
comunicación inalámbrica no sea tan
confiable cuando se encuentran los
obstáculos siguientes entre el hub y otros
dispositivos.
R Puertas o pantallas metálicas
R Par
edes que contengan aislamiento de
aluminio
R Paredes de hormigón o hierro corrugado
R Ventanas de vidrio doble
R Varias paredes
R Cuando los dispositivos están en pisos o
edificios diferentes
Nota:
R Puede verificar el estado de la
comunicación del sensor presionando
M
N. Si el Led indicador está
iluminado en verde o rojo, el sensor se
está comunicando de forma adecuada
con el hub. Si el Led indicador parpadea
en rojo, se encuentra fuera de alcance
del hub.
Para obtener ayuda, visite http://shop.panasonic.com/support
5
Configuración
HNS103_(es_es)_0202_ver.101.pdf 5 2017/02/02 15:38:21
Instalación
La unidad principal se instala en la pared, y la unidad de sonda puede instalarse en la pared
o sobre el piso.
Cuando las sondas metálicas de la unidad de sonda entran en contacto con agua, fluye una
pequeña descarga eléctrica entre las sondas, lo cual es reconocido por la unidad principal
como una pérdida de agua.
Unidad de sonda instalada en pared
Unidad de sonda instalada sobre el pi-
so
Precauciones de instalación
R El sensor no está diseñado para usarse en situaciones que requieran alta confiabilidad.
No recomendamos el uso del sensor en estas situaciones.
R Panasonic no asume ninguna responsabilidad por lesiones o daños provocados por el
uso de este producto.
R Cuando realice la instalación, asegúrese de que la batería esté colocada
adecuadamente y que la tapa de la unidad principal est
é cerrada por completo.
R Al instalar en una superficie de madera, use los adaptadores de instalación en pared que
se incluyen. Use tornillos para colocar los adaptadores para montaje en la pared (no use
cinta de doble cara).
R Monte el sensor en una ubicación estable donde se pueda sostener correctamente.
R No coloque el sensor sobre un material blando. Podría caerse, romperse o provocar
lesiones.
R No monte el sensor en las siguientes ubicaciones: tablas de yeso, hormigón celular,
bloques de hormigón, contrachapados con grosor inferior a 25.4 mm (1 pulgada), etc.
R El sensor no puede detectar adecuadamente una fuga de agua si el agua contiene
contaminantes tales como aceite o si el agua estuviera congelada (es decir, hielo o
nieve).
6
Para obtener ayuda, visite http://shop.panasonic.com/support
Configuración
HNS103_(es_es)_0202_ver.101.pdf 6 2017/02/02 15:38:21
R Instale la unidad de sonda de modo que las sondas de metal queden horizontales. Una
pérdida de agua solo se puede detectar si el agua toca ambas sondas de metal; si el
agua toca solamente una de las sondas, no se detectará la pérdida de agua.
Instalación correcta Instalación incorrecta
Las sondas de metal son paralelas al piso
Las sondas de metal no son paralelas al
piso
Ubicación de la instalación
Instale el sensor de fuga de agua en sótanos, cocinas, lavaderos o en el lugar donde quiera
detectar pérdidas de agua. Los ejemplos comunes de instalación incluyen lavarropas,
calentadores de agua o lugares donde se produjeron pérdidas de agua anteriormente.
Nota:
R Instale la unidad de sonda de modo que las sondas de metal queden aproximadamente
a 1 mm (1/32 pulgadas) sobre e
l nivel del piso. Si la sonda toca el piso, es posible que el
sensor realice detecciones falsas. Si las sondas están muy alejadas del piso, las
pérdidas de agua solo pueden detectarse una vez que la pérdida sea lo suficientemente
profunda y toque las sondas.
R Instale la unidad principal 1 m (3 pies 3 pulgadas) o más sobre el nivel del piso. La
unidad principal no es a prueba de agua; si se humedece es posible que el sensor se
dañe y que las pérdidas de agua no se detecten adecuadamente.
Para obtener ayuda, visite http://shop.panasonic.com/support
7
Configuración
HNS103_(es_es)_0202_ver.101.pdf 7 2017/02/02 15:38:21
Colocación con los adaptadores de instalación en pared
1 Use tornillos para sujetar los adaptadores para montaje en la pared.
n Unidad principal
1
Tornillos
2
75 mm (2 15/16 pulgadas)
n Unidad de sonda
1
Tornillo
2
1
1
1
Nota:
R Para instalar la unidad de sonda sobre un piso, consulte página 11. En este caso,
no debe usar el adaptador de instalación en pared de la unidad de sonda.
8
Para obtener ayuda, visite http://shop.panasonic.com/support
Configuración
HNS103_(es_es)_0202_ver.101.pdf 8 2017/02/02 15:38:21
2 Quite la parte posterior de la cinta de doble cara, inserte la unidad principal y la unidad
de sonda en los adaptadores de instalación en pared y presione firmemente en cada
unidad para garantizar una adhesión sólida a la superficie de instalación.
3
Cinta adhesiva de doble cara
3
3
3
Para obtener ayuda, visite http://shop.panasonic.com/support
9
Configuración
HNS103_(es_es)_0202_ver.101.pdf 9 2017/02/02 15:38:21
Colocación solo con cinta adhesiva de doble cara
Nota:
R Asegúrese de que las superficies que estarán en contacto con la cinta de doble cara
estén limpias y secas antes de aplicar la cinta. Al colocar la cinta de doble cara sobre
hormigón o ladrillos, si la superficie de estos está húmeda, asegúrese de secarla
completamente antes de colocar la cinta de doble cara.
1 Quite la parte posterior de la cinta de
doble cara, pegue la unidad principal y la unidad
de sonda a la superficie de instalación y presione firmemente en cada unidad para
garantizar una adhesión sólida a la superficie de instalación.
1
Cinta adhesiva de doble cara
1
1
1
Nota:
R Para instalar la unidad de sonda sobre un piso, consulte página 11.
10
Para obtener ayuda, visite http://shop.panasonic.com/support
Configuración
HNS103_(es_es)_0202_ver.101.pdf 10 2017/02/02 15:38:21
Instalación de la unidad de sonda sobre un piso
Cuando instale la unidad de sonda sobre un piso, use la cinta de doble cara para pegar la
unidad de sonda directamente sobre el piso.
Nota:
R Si la unidad de sonda se inserta en el adaptador de instalación en pared y se pega en un
piso, las sondas estarán muy lejos del piso y, por lo tanto, solo se detectarán pérdidas de
agua una vez que el agua sea lo sufi
cientemente profunda como para tocar las sondas.
Instalación correcta Instalación incorrecta
Agua poco profunda toca las sondas
Solo el agua profunda puede tocar las
sondas
A
A Adaptador de instalación en pared
Para obtener ayuda, visite http://shop.panasonic.com/support
11
Configuración
HNS103_(es_es)_0202_ver.101.pdf 11 2017/02/02 15:38:21
Extracción de la pared
n Extracción de los adaptadores de instalación en pared
1 Inserte un destornillador plano en las muescas de los adaptadores de instalación en
pared y quite cuidadosamente la unidad principal y la unidad de sonda.
2 Quite los tornillos que fijan los adaptadores de instalación a la pared.
n Extracción cuando se asegura con cinta adhesiva de doble cara
1 Ate un pedazo de hilo a dos palos, destornilladores, etc.
2 Tire firmemente del hilo y úselo para cortar la cinta de doble cara, y luego elimine
cualquier exceso de cinta.
1
Exceso de cinta
12
Para obtener ayuda, visite http://shop.panasonic.com/support
Configuración
HNS103_(es_es)_0202_ver.101.pdf 12 2017/02/02 15:38:22
Prueba del sensor
Puede observar el Led indicador del sensor
para probar el funcionamiento del sensor.
1 Quite la tapa de la unidad principal.
2 Oprima M
N.
3 Toque las sondas de la unidad de
sonda de agua.
4 Confirme que el Led indicador se
encienda en rojo.
5 Presione M
N de nuevo.
Acceso a la Guía del
usuario
La Guía del usuario es una colección de
documentación en línea que lo ayuda a
aprovechar al máximo la aplicación [Home
Network].
1 iPhone
®
/iPad
®
Toque
en la pantalla de inicio de
la aplicación.
Dispositivos Android
Toque
u oprima el botón menú de
su dispositivo en la pantalla de inicio
de la aplicación.
2 Toque [Guía del Usuario].
Nota:
R No se admite Microsoft
®
Windows
®
Internet Explorer
®
8 y versiones
anteriores.
R Se recomienda Android 4.1 y versiones
posteriores.
R También puede acceder a la Guía del
usuario mediante la página web a
continuación.
www.panasonic.net/pcc/support/tel/
homenetwork/manual/
Para obtener ayuda, visite http://shop.panasonic.com/support
13
Apéndice
HNS103_(es_es)_0202_ver.101.pdf 13 2017/02/02 15:38:22
14
Notas
HNS103_(es_es)_0202_ver.101.pdf 14 2017/02/02 15:38:22
15
Notas
HNS103_(es_es)_0202_ver.101.pdf 15 2017/02/02 15:38:22
HNS103_(es_es)_0202_ver.101.pdf 16 2017/02/02 15:38:22
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Panasonic KXHNS103 Instrucciones de operación

Tipo
Instrucciones de operación

En otros idiomas