Legrand HCL453PMMTC Guía de instalación

Tipo
Guía de instalación

Este manual también es adecuado para

No: 341102 – 01/15
Pass & Seymour
®
Harmony
®
Multilocation Dimmer; Ratings: Incandescent: 700W; CFL, LED: 450W; MLV 700VA
Harmony
®
Variateur à multilocalisation ; Puissance nominale : à incandescence ; 700 W ;
lampe uo-compacte, DEL : 450 W ; transformateur 700 VA
Regulador de ubicación múltiple Harmony
®
; especicaciones: Incandescente: 700 W; CFL, LED: 450 W; MLV 700 VA
Installation Instructions • Notice d’Installation • Instrucciones de Instalación
Catalog Number(s) • Numéro(s) de catalogue • Número(s) de catálogo: HCL453PMM and HMR
Country of Origin: Made in China • Pays d’origine : Fabriqué en Chine • País de origen: Hecho en China
IMPORTANT NOTES:
1. All dimmers can be damaged by improper wiring. Check for short circuits
prior to installing the dimmer with a lamp load in the circuit.
Procedure for short circuit check:
a. Disconnect power to circuit by removing fuse or turn circuit breakers
OFF.
b. Install a switch instead of the dimmer. Turn the switch to the ON position.
c. Turn power ON. If the circuit breaker trips, a short circuit is present.
If the light fails to turn ON and OFF with the switch, the wiring may
be incorrect.
d. Correct wiring, if necessary, and retest.
e. Install the dimmer only after the light operates properly with the switch.
2. Protect this product from dust and dirt. The dimmer can be damaged by
contaminates encountered during the construction process. If lighting
is required prior to the construction process completion, then a switch
should be temporarily installed in place of this product. This product
should not be installed until the construction process is complete.
Any dimmer damage due to improper installation is not covered
under warranty.
DIRECTIONS
Figure 1 / Figure 1 / Figura 1
1. If color change kit was provided, and a different color is desired, see the
Color Change Procedure, (Figure 1), if not proceed to step #2.
2. Disconnect power to the circuit by removing the fuse or turning the circuit
breaker to the off position.
3. Remove wall plate and switch mounting screws, pull existing switch from
wall box.
4. Disconnect existing switch from circuit. For existing 3-way installations:
identify the “Common” wire (wire connected to the terminal marked
common, this terminal may also be of a different color). For new
installation identify wire connected to power source or load.
5. Connect dimmer as shown in the applicable installation diagram using
#12 or #14 AWG wire stranded or solid copper conductors. Note that
the dimmer and remote positions may not be reversed from that shown.
Strip the wire to the length shown on the back of the product.
6. Install product in wall box, with the word “Top” on the strap right side up,
using mounting screws provided.
7. Attach wall plate and then restore power to the unit.
8. The dimmer may require adjustment to the low end setting to reliably
start and/or remove flickering in bulbs. Make adjustment as stated in
the “User Adjustable Parameters” section of the DIMMER OPERATION
section.
NOTE: It is normal for the dimmer to feel warm during operation. Use a
separate neutral wire for each phase of a multiphase system containing
a dimmer, and for high power single phase applications where flickering
is present.
Any combination of dimmer models and other devices may be ganged
together. De-rate the maximum load according to the following table:
Rated Load 3 Gang (or more) Installation
Incd./Hal. 700W 650W
MLV 700VA 650VA
CLF/LED 450W 450W
Single-Pole Installation
1. NOTE: Wire colors indicated are those of the device only, not the wires
in the wall box. Be sure to test wall box wires before making any
connections.
2. Connect the device following the single-pole wiring diagram shown.
Three-Way Installation
1. NOTE: Three-way or multi-location applications require the use of a Multi-
Location Remote HMR, in conjunction with a Preset Dimmer. A regular
three-way switch should not be used to control a Multi-Location Dimmer.
Doing so may damage the control and, in turn, void the unit’s warranty.
See Wiring Diagram Figures 2-5 below.
OPERATION
User Interface – Overview
The user interface of the dimmer consists of:
[1] Locator LED
[2] ON/OFF Pushbutton
[3] Seven-Element LED Bar Graph
[4] Air Gap Switch
[5] RAISE/LOWER Rocker buttons
LED Indicators
Load Off – When the dimmer is powered, but
the load is OFF, the locator LED [1] will be on at the full intensity
(if enabled), and all LEDs in the bar graph [3] will be off.
Load On – When the dimmer is operating the load (load ON), the locator
LED [1] will be off, and the bar graph [3] will be illuminated starting from
the bottom, to indicate the present load brightness level.
Setup Modes – The function of the LEDs varies with each specific setup
mode, and will be detailed in those descriptions.
ON/OFF Pushbutton [2]
Momentary push of ON/OFF button with Load OFF fades load on to LDL
(last dim level) at 50%/second.
Momentary push of ON/OFF button with Load ON fades load off at a
rate of 50%/second (from full on, it will take 2 sec to off).
Push and hold of ON/OFF button for approximately 2s with load ON
fades load off over approximately 30s (“go to bed” feature). During the
slow fade-off interval the top-most lit LED in the bar graph will flash at
approximately 3Hz (3 times per second).
Double-tap of ON/OFF button with Load ON fades load to maximum
brightness at 50%/second.
RAISE Rocker button (+) [5]
Momentary push with Load ON increases brightness 1 increment
(approx. 7% of max brightness).
Push and hold for more than 0.5 seconds with Load ON ramps
brightness up at 20%/second (approx 5 sec from min to max).
LOWER Rocker button (-) [5]
Momentary push with Load ON decreases brightness 1 increment
(approx 7% of max brightness).
Push and hold for more than 0.5 seconds with load ON ramps brightness
down at 20%/second (approx 5 sec from max to min).
Air gap switch [4]
Slide to OFF position before replacing load. Slide to ON position after
load has been replaced.
USER-ADJUSTABLE PARAMETERS
Min Level Trim
Hold LOWER Rocker button (-) [5] down for approximately 10s after
minimum brightness reached. Bar graph LEDs will flash to indicate
calibration mode activated.
Pressing ON/OFF pushbutton [2] cycles through 12 preset trim levels,
which are displayed on the bar graph.
Pressing either the Raise or Lower rocker button [5] exits calibration and
stores selected trim level.
The default value for the min level trim is set to a level adequate for stable
operation of a typical LED load.
Max Level Trim (energy saver)
Hold RAISE Rocker button (+) [5] down for approximately 10s after
maximum brightness reached. Bar graph LEDs will flash to indicate cal
mode activated.
Pressing ON/OFF pushbutton [2] cycles through 12 preset trim levels,
which are displayed on the bar graph.
Pressing either Raise or Lower rocker pushbuttons exits calibration and
stores selected trim level.
The default value for the max level trim is 100%.
Disable/Enable Locator LED [1]
Holding the ON/OFF pushbutton [2] down for approximately 10s with load
OFF, until Locator LED flashes once in confirmation, disables operation
of the Locator LED when load is off. Continuing to hold the button for an
additional 2s (12s total), until the Locator LED flashes twice in confirmation,
enables the Locator LED operation.
Factory Reset
With the unit in the OFF state, hold down the ON/OFF pushbutton [2] for
15 seconds. The bar graph and locator LEDs will flash 3 times to indicate
that the minimum and maximum trim levels and locator LED parameters
have been reset to defaults.
Power Failure Recovery
In the case of a power failure, the dimmer saves its last operating state to
memory. When power is restored, if the dimmer load was on, the dimmer
will automatically fade, at 20%/second rate, to the level at the time of the
power failure.
DIMMER / VARIATEUR / REGULADOR
REMOTE / TÉLÉCOMMANDE /
DISPOSITIVO REMOTO
REMOTE / TÉLÉCOMMANDE /
DISPOSITIVO REMOTO
Line (Hot/Black) Wire
Noir – Câble secteur/Sous tension
Cable de línea (vivo/negro)
120VAC
60Hz
120 VCA,
60 Hz
120 V CA,
60 Hz
Load
Charge
Carga
Neutral (White) Wire / Fil neutre (blanc) / Cable neutro (blanco)
Green Wire
Fil vert
Cable verde
Terminal Labeled Remote Red Screw
Borne marquée télécommandée – Vis rouge
Terminal etiquetada
para el dispositivo
remoto; tornillo rojo
Terminal Labeled Remote Red Screw
Borne marquée télécommandée – Vis rouge
Terminal etiquetada
para el dispositivo
remoto; tornillo rojo
Terminal Labeled
Remote Red Screw
Borne marquée
télécommandée –
Vis rouge
Terminal etiquetada
para el dispositivo
remoto; tornillo rojo
Ground
Tierre
Tierra
Ground
Tierre / Tierra
Traveler Wire #2
Fil mobile n° 2
Cable puente n.º 2
Traveler Wire #1 / Fil mobile n° 1 / Cable puente n.º 1
Terminal Labeled
Load Brass Screw
Borne marquée
charge – Vis en laiton
Terminal etiquetada
para la carga;
tornillo de latón
Terminal Labeled
Load Brass Screw
Borne marquée charge –
Vis en laiton
Terminal etiquetada para
la carga; tornillo de latón
Terminal Labeled
Load Brass Screw
Borne marquée charge –
Vis en laiton
Terminal etiquetada para
la carga; tornillo de latón
Green Wire
Fil vert
Cable verde
Green Wire
Fil vert
Cable verde
Terminal Labeled
Hot, Black Screw
Borne marquée chaude –
Vis noire
Terminal etiquetada
para el conductor
vivo; tornillo negro
!
* *
Line (Hot/Black) Wire
Noir – Câble secteur/Sous tension
Cable de línea (vivo/negro)
120VAC
60Hz
120 VCA,
60 Hz
120 V CA,
60 Hz
Load
Charge
Carga
Neutral (White) Wire / Fil neutre (blanc) / Cable neutro (blanco)
Green Wire
Fil vert
Cable verde
Terminal Labeled
Remote Red Screw
Borne marquée
télécommandée –
Vis rouge
Terminal etiquetada
para el dispositivo
remoto; tornillo rojo
Terminal Labeled Remote Red Screw
Borne marquée télécommandée – Vis rouge
Terminal etiquetada
para el dispositivo
remoto; tornillo rojo
Terminal Labeled
Remote Red Screw
Borne marquée
télécommandée –
Vis rouge
Terminal etiquetada
para el dispositivo
remoto; tornillo rojo
Ground
Tierre
Tierra
Ground
Tierre
Tierra
Ground
Tierre / Tierra
Terminal Labeled
Load Brass Screw
Borne marquée charge –
Vis en laiton
Terminal etiquetada para
la carga; tornillo de latón
Terminal Labeled
Load Brass Screw
Borne marquée charge –
Vis en laiton
Terminal etiquetada para
la carga; tornillo de latón
Green Wire
Fil vert
Cable verde
Green Wire
Fil vert
Cable verde
Terminal Labeled
Hot, Black Screw
Borne marquée
chaude – Vis noire
Terminal etiquetada
para el conductor
vivo; tornillo negro
*Either load terminal can be used / *N’importe quelle borne de charge peut être utilisée / *Se puede usar cualquier terminal de carga.
DIMMER / VARIATEUR / REGULADOR
REMOTE / TÉLÉCOMMANDE /
DISPOSITIVO REMOTO
REMOTE / TÉLÉCOMMANDE /
DISPOSITIVO REMOTO
HCL453PMM
READ AND SAVE THESE INSTRUCTIONS
To be installed by a certified electrician or other qualified person.
WARNING: To prevent severe shock or electrocution, always turn power off at the
service panel before installing this product, working on the circuit or changing a lamp.
CAUTION
To reduce the risk of overheating and possible damage to this product or other
equipment do not use this product to control a receptacle, a motor operated
appliance or a transformer based appliance.
Do not use this product with loads whose power requirements exceed the maximum
power (stated in watts, amperes or volt-amperes) of the dimmer.
Use only with incandescent, compatible dimmable CFL/LED bulbs which screw into
conventional incandescent lamp sockets, or MLV loads (compatible bulbs listed at
www.legrand.us).
A 5 watt minimum load is required.
Do not connect this product to a power source other than 120VAC, 60Hz.
Use copper wire only.
Always slide the Air Gap Switch to the full down (OFF) position when changing a light
bulb.
For MLV loads:
- The maximum VA rating of this dimmer applies to the transformer input of the MLV,
not the load connected to the transformer secondary of the MLV.
- Do not use to control a solid state electronic low voltage transformer.
- Do not use with inoperative or missing lamps. Use of this dimmer with inoperative
or missing lamps can create an over current condition which may damage the
transformer. Use transformers that incorporate thermal protection or a fuse at the
primary windings.
LISEZ ET CONSERVEZ CES INSTRUCTIONS
Ce dispositif doit être installé par un électricien certifié ou une autre personne qualifiée.
AVERTISSEMENT : afin d’éviter tout choc électrique ou électrocution grave, toujours
éteindre l’alimentation sur le panneau de service avant d’installer ce produit, de
travailler sur le circuit ou de changer une lampe.
MISE EN GARDE :
Pour réduire le risque de surchauffe et d’autres dommages possibles sur ce produit
ou d’autres appareils, ne pas utiliser ce produit pour contrôler une prise électrique,
un appareil à moteur ou un appareil avec transformateur.
Ne pas utiliser ce produit avec des ampoules dont les besoins en énergie dépassent
la puissance maximale (exprimée en watts, en ampères ou en voltampères) du
variateur.
Utiliser uniquement ce produit avec des ampoules compatibles, à incandescence,
fluo-compactes/DEL, à intensité réglable, pouvant être vissées dans des douilles
conventionnelles pour ampoules à incandescence, ou des charges de transformateur
(ampoules compatibles répertoriées sur le site www.legrand.us).
Une ampoule d’au moins 5 watts est requise.
Ne brancher ce produit qu’à une source d’alimentation de 120 V c.a., 60 Hz.
N’utilisez que des fils en cuivre.
Au moment de changer l’ampoule, faire glisser l’interrupteur Air Gap jusque dans sa
position la plus basse (OFF).
Pour les charges de transformateur :
- La capacité maximale en VA de ce dispositif s’applique à l’entrée du transformateur
et non pas à la charge au niveau de la partie secondaire du transformateur.
- Ne pas s’en servir pour commander un transformateur électronique basse tension
à semi-conducteurs.
- N’utilisez pas ce dispositif avec des lampes défaillantes ou manquantes.
L’utilisation de cette unité avec des lampes défaillantes ou manquantes peut créer
une situation de surintensité qui risque d’endommager le transformateur. Utilisez
des transformateurs équipés d’une protection thermique ou d’un fusible au niveau
des enroulements primaires.
LEA Y GUARDE ESTAS INSTRUCCIONES
La instalación debe estar a cargo de un electricista certificado u otra persona
calificada.
ADVERTENCIA: Para evitar una fuerte descarga eléctrica o la electrocución, siempre
desconecte el suministro eléctrico en el panel de servicio antes de instalar este
producto, trabajar en el circuito o cambiar una lámpara.
PRECAUCIÓN
Para reducir el riesgo de sobrecalentamiento y posibles daños a este producto u
otros equipos, no use este producto para controlar un receptáculo, un dispositivo
accionado por motor o un dispositivo con transformador.
No use este producto con cargas cuyos requisitos de potencia superen la potencia
máxima (expresada en vatios, amperios o voltio-amperios) del regulador.
Úselo solo con bombillas CFL/LED incandescentes regulables compatibles que se
inserten en casquillos para lámparas incandescentes convencionales o con cargas
MLV (bombillas compatibles detalladas en www.legrand.us).
Se requiere una carga mínima de 5 W.
No conecte este producto a una fuente de alimentación que no sea de 120 V AC,
60 Hz.
Use solamente cables de cobre.
Siempre deslice el interruptor de espacio de aire a la posición totalmente hacia abajo
(apagado) al cargar una bombilla.
Para las cargas MLV:
- La capacidad nominal máxima de VA de este regulador corresponde a la entrada
del transformador de MLV, no a la carga conectada al transformador secundario
del MLV.
- No lo use para controlar un transformador de bajo voltaje electrónico de estado
sólido.
- No lo use con lámparas defectuosas o faltantes. El uso del regulador con lámparas
defectuosas o faltantes puede crear una condición de corriente en exceso que
puede dañar el transformador. Use los transformadores que tienen protección
térmica o un fusible en los arrollamientos primarios.
HMR
Two or More Location Control (Up to 9 Remotes) Wiring Option B: Connecting Remote To Neutral
Contrôle de localisation double ou davantage (jusqu’à 9 télécommandes) Option de câblage B :
Raccordement de la télécommande au neutre
Opción de cableado B para control de dos o más ubicaciones (hasta 9 dispositivos remotos):
Conexión de dispositivo remoto a neutro
1. 2. 3.
4. 5. 6.
Ground
Tierre
Tierra
Terminal Labeled
Remote. Red Screw
Is Not Used.
Borne marquée
télécommandée.
La vis rouge n’est
pas utilisée.
Terminal etiquetada
para el dispositivo
remoto. El tornillo
rojo no se usa.
120VAC
60Hz
120 VCA,
60 Hz
120 V CA,
60 Hz
Load
Charge
Carga
Terminal Labeled Hot - Black Screw
Borne marquée chaude - Vis noire
Terminal etiquetada para el conductor
vivo; tornillo negro
Neutral (White) Wire
Fil neutre (blanc)
Cable neutro (blanco)
Line (Hot/Black) Wire
Borne marquée chaude - Vis noire
Cable de línea (vivo/negro)
Terminal
Labeled Load
Brass Screw
Borne marquée
charge - Vis
en laiton
Terminal
etiquetada
para la carga;
tornillo de latón
Green Wire
Fil vert
Cable verde
DIMMER / VARIATEUR / REGULADOR
Figure 2 / Figure 2 / Figura 2
Terminal Labeled Remote Red Screw
Borne marquée télécommandée – Vis rouge
Terminal etiquetada para el
dispositivo remoto; tornillo rojo
Line (Hot/Black) Wire
Noir – Câble secteur/Sous tension
Cable de línea (vivo/negro)
REMOTE / TÉLÉCOMMANDE /
DISPOSITIVO REMOTO
DIMMER / VARIATEUR / REGULADOR
Terminal Labeled
Remote Red Screw
Borne marquée
télécommandée –
Vis rouge
Terminal etiquetada
para el dispositivo
remoto; tornillo rojo
120VAC
60Hz
120 VCA,
60 Hz
120 V CA,
60 Hz
Ground
Tierre
Tierra
Ground
Tierre / Tierra
Load
Charge
Carga
Traveler Wire #2
Fil mobile n° 2
Cable puente n.º 2
Traveler Wire #1 / Fil mobile n° 1 / Cable puente n.º 1
Neutral (White) Wire / Fil neutre (blanc) / Cable neutro (blanco)
Terminal Labeled
Load Brass Screw
Borne marquée
charge – Vis en laiton
Terminal etiquetada
para la carga;
tornillo de latón
Terminal Labeled
Load Brass Screw
Borne marquée charge –
Vis en laiton
Terminal etiquetada para
la carga; tornillo de latón
Green Wire
Fil vert
Cable verde
Green Wire
Fil vert
Cable verde
Terminal Labeled
Hot, Black Screw
Borne marquée
chaude – Vis noire
Terminal etiquetada
para el conductor
vivo; tornillo negro
Figure 3 / Figure 3 / Figura 3
WIRING DIAGRAMS / SCHÉMAS DE CÂBLAGE / DIAGRAMAS DE CABLEADO
Single Location Control (Using Existing Single Pole Switch Wiring)
Contrôle de localisation unique (à l’aide du câblage de commutation
unipolaire existant)
Control de una sola ubicación (con el cableado del interruptor unipolar existente)
Two Location Control (Using Existing 3-Way Switch Wiring)
Contrôle de localisation double (à l’aide du câblage de commutation à trois voies existant)
Control de dos ubicaciones (con el cableado del interruptor de 3 vías existente)
Figure 4 / Figure 4 / Figura 4 Figure 5 / Figure 5 / Figura 5
Two or More Location Control (Up to 9 Remotes) Wiring Option A: Connecting Load Through Remotes
Contrôle de localisation double ou davantage (jusqu’à 9 télécommandes) Option de câblage A :
Raccordement d’une charge par le biais de télécommandes
Opción de cableado A para control de dos o más ubicaciones (hasta 9 dispositivos remotos) A:
Conexión de la carga a través de dispositivos remotos
800.223.4185
1.877.BY.LEGRAND
www.legrand.us
www.legrand.ca
No: 341102 – 01/15
© Copyright 2015 Legrand All Rights Reserved.
© Copyright 2015 Tous droits réservés Legrand.
© Copyright 2015 Legrand Todos los derechos reservados.
For covering patents, see www.legrand.us/patents
Pour connaître les brevets applicables, consultez www.legrand.us/patents
Para obtener patentes de protección, visite www.legrand.us/patents
REMARQUES IMPORTANTES
1. Tous les variateurs peuvent être endommagés en cas de câblage
incorrect. Vérifiez qu’il n’y a pas de court-circuit avant d’installer le
variateur sur une ampoule dans le circuit.
Produre pour la recherche de court-circuit :
a. Déconnectez l’alimentation du circuit en retirant un fusible ou en
mettant les disjoncteurs sur OFF (Arrêt).
b. Installez un interrupteur plutôt qu’un variateur. Mettez l’interrupteur en
position ON (Marche).
c. Mettez le courant en marche. Si le disjoncteur se déclenche, il existe
un court-circuit. Si la lumière ne s’allume et ne s’éteint pas avec
l’interrupteur, le câblage est probablement incorrect.
d. Corrigez le câblage si nécessaire puis retestez.
e. N’installez le variateur qu’une fois que la lumière fonctionne
correctement avec l’interrupteur.
2. Protégez ce produit de la poussière et de la saleté. Le variateur peut
être endommagé s’il est exposé à des éléments contaminants au cours
du processus de construction. Si un éclairage est requis avant la fin
du processus de construction, un interrupteur doit alors être installé
temporairement à la place du variateur. Ce produit ne doit être installé
qu’une fois le processus de construction terminé.
Les dommages au variateur engendrés par une mauvaise installation
ne sont pas couverts par la garantie.
INSTRUCTIONS
1. Si une trousse de changement de couleur est fournie et que vous
souhaitez changer de couleur, consultez la Procédure de changement
de couleur (figure 1). Sinon, passez directement à l’étape 2.
2. Déconnectez l’alimentation du circuit en retirant un fusible ou en mettant
les disjoncteurs sur OFF.
3. Retirez la plaque murale et les vis de fixation de l’interrupteur, puis
retirez l’interrupteur existant du boîtier mural.
4. Déconnectez l’interrupteur existant du circuit. Pour les installations à 3
voies existantes : identifiez le fil commun (fil connecté à la borne portant
le marquage correspondant. Cette borne est parfois d’une autre couleur).
Pour de nouvelles installations, identifiez le fil connecté à la source
d’alimentation ou à l’ampoule.
5. Connectez le variateur tel qu’illustré dans le schéma d’installation en
utilisant des fils multibrins de 2,05 ou 1,63 mm de diamètre ou de solides
conducteurs en cuivre. Veuillez noter que le variateur et les 3 positions
de l’interrupteur peuvent également être inversés par rapport à ce qui est
illustré. Dénudez le fil sur la longueur indiquée au dos du produit.
6. À l’aide des vis de fixation fournies, installez le produit dans le boîtier
mural en plaçant le côté droit de la sangle où figure le mot « Haut » vers
le haut.
7. Fixez la plaque murale puis restaurez l’alimentation de l’unité.
8. Le variateur peut nécessiter un ajustement des réglages minimum pour
pouvoir démarrer en toute fiabilité et/ou stopper les vacillements des
ampoules. Veuillez suivre les indications fournies dans le paragraphe «
Ajustements par l’utilisateur » de la section « FONCTIONNEMENT DU
VARIATEUR ».
REMARQUE : Il est normal que le variateur soit légèrement chaud durant
son fonctionnement. Utilisez un fil neutre différent pour chaque phase
d’un système multiphase contenant un variateur et pour les applications
monophases haute puissance en présence de vacillements.
Dans le cas d’une utilisation de plusieurs modèles de variateurs et d’autres
appareils, ces derniers peuvent être raccordés ensemble. Déclasser la
charge maximum selon le tableau suivant :
Charge nominale Installation triple (ou plus)
Incd./Hal. 700W 650W
MLV 700VA 650VA
CLF/LED 450W 450W
Installation unipolaire
1. REMARQUE : Les fils indiqués en couleur sont ceux de l’appareil
uniquement et non ceux du boîtier mural. Avant tout raccordement,
veillez à tester les fils du boîtier mural.
2. Connectez l’appareil conformément au schéma de câblage unipolaire
illustré.
Installation à trois voies
1. REMARQUE : Les applications à trois voies ou à multilocalisation
nécessitent de recourir à une télécommande à multilocalisation HMR,
associé à un variateur préréglé. N’utilisez pas d’interrupteur à trois voies
normal pour commander le variateur à multilocalisation. Vous risqueriez
ainsi d’endommager la commande et d’annuler la garantie de l’unité.
Voir le schéma de câblage, figures 2-5.
FONCTIONNEMENT
Vue d’ensemble de l’interface utilisateur
L’interface utilisateur du variateur se compose
des éléments suivants :
[1] DEL du dispositif de localisation
[2] Bouton poussoir ON/OFF
[3] Graphique à barres des DEL
à sept éléments
[4] Interrupteur Air Gap
[5] Touches à bascule LEVER/BAISSER
Voyants DEL
Lumière éteinte – Lorsque le variateur est alimenté, mais que la lumière
est éteinte, la DEL du dispositif de localisation [1] est allumée à pleine
puissance (en cas d’activation), et toutes les DEL du graphique à barres
[3] sont éteintes.
Lumière allumée – Lorsque le variateur commande la charge (lumière
allumée), la DEL du dispositif de localisation [1] est éteinte, et le graphique
à barres [3] s’allume en commençant par le bas afin d’indiquer le niveau de
luminosité de charge en présence.
Modes de configuration – Le fonctionnement des DEL varie selon le
mode de configuration et est détaillé dans ces descriptions.
Bouton poussoir ON/OFF [2]
Lorsque la lumière est éteinte, pour l’allumer progressivement jusqu’au
niveau LDL (dernier niveau de réglage) à raison de 50 %/seconde,
appuyer rapidement sur le bouton ON/OFF.
Lorsque la lumière est allumée, pour l’éteindre progressivement à un
rythme de 50 %/seconde (de pleinement activée, il lui faudra 2 s pour
s’éteindre), appuyer rapidement sur le bouton ON/OFF.
Si l’on appuie sur le bouton ON/OFF et qu’on le maintient
enfoncé pendant env. 2 s avec la lumière allumée, celle-ci s’éteint
progressivement en environ 30 s (fonction de « mise au lit »). Pendant
cet intervalle d’extinction progressive lente, la DEL du haut dans le
graphique à barres clignote à environ 3Hz (3 fois par seconde).
Lorsque la lumière est allumée, pour augmenter progressivement le
degré jusqu’à atteindre la luminosité maximale à 50 %/seconde, appuyer
deux fois sur le bouton ON/OFF.
Touche à bascule LEVER (+) [5]
Pour augmenter la luminosité d’un palier (environ 5 % de la luminosité
maximale), appuyer rapidement sur le haut de la palette lorsque la
lumière est allumée.
Si l’on appuie sur le bouton et qu’on le maintient enfoncé pendant plus
de 0,5 seconde avec la lumière allumée, la luminosité augmente à raison
de 20 %/seconde (env. 5 s pour passer du niveau min. au niveau max.).
Touche à bascule BAISSER (-) [5]
Pour diminuer la luminosité d’un palier (environ 5 % de la luminosité
maximale), appuyer rapidement sur le bas de la palette lorsque la
lumière est allumée.
Si l’on appuie sur le bouton et qu’on le maintient enfoncé pendant plus
de 0,5 seconde avec la lumière allumée, la luminosité diminue à raison
de 20 %/seconde (env. 5 s pour passer du niveau min. au niveau max.).
Interrupteur Air Gap [4]
Faire glisser en position OFF avant de remplacer la charge. Faire glisser
en position ON une fois la charge remplacée.
PARAMÈTRES RÉGLABLES PAR L’UTILISATEUR
Réglage du niveau minimum
Maintenir la touche à bascule BAISSER (-) [5] enfoncée pendant environ
10 s une fois le niveau de luminosité minimal atteint. Les DEL du
graphique à barres clignotent pour indiquer que le mode d’étalonnage
est activé.
Appuyer sur le bouton poussoir ON/OFF [2] pour passer d’un niveau
de réglage à l’autre parmi les 12 qui sont prédéfinis et affichés dans le
graphique à barres.
Appuyer sur la touche à bascule LEVER ou ABAISSER [5] pour quitter
le mode d’étalonnage et enregistrer le niveau de réglage sélectionné.
La valeur par défaut du réglage de niveau min. est définie sur un niveau
permettant d’assurer le fonctionnement stable d’une charge de DEL
normale.
Ajustement du niveau maximum (éco-énergétique)
Maintenir la touche à bascule LEVER (+) [5] enfoncée pendant env.
10 s une fois le niveau de luminosité de luminosité atteint. Les DEL du
graphique à barres clignotent pour indiquer que le mode d’étalonnage
est activé.
Appuyer sur le bouton poussoir ON/OFF [2] pour passer d’un niveau
de réglage à l’autre parmi les 12 qui sont prédéfinis et affichés dans le
graphique à barres.
Appuyer sur le bouton poussoir Lever ou Baisser pour quitter le mode
d’étalonnage et enregistrer le niveau de réglage sélectionné.
La valeur par défaut du réglage de niveau max. est de 100 %.
sactiver/activer la DEL du dispositif de localisation [1]
Maintenir le bouton poussoir ON/OFF [2] enfoncé pendant environ 10
s alors que la lumière est éteinte jusqu’à ce que la DEL du dispositif de
localisation clignote une fois en guise de confirmation, et désactive la DEL
du dispositif de localisation lorsque la lumière est éteinte. Maintenir encore
le bouton enfoncé pendant 2 s supplémentaires (12 s au total) jusqu’à
ce que la DEL du dispositif de localisation clignote deux fois en guise de
confirmation, et active la DEL du dispositif de localisation.
Réinitialisation
Lorsque l’unité est éteinte, maintenir le bouton poussoir ON/OFF [2]
enfoncé pendant 15 secondes. Les DEL du graphique à barres et du
dispositif de localisation clignotent 3 fois pour indiquer que les niveaux de
réglage minimum et maximum, et les paramètres des DEL du dispositif de
localisation ont été réinitialisés sur leurs valeurs par défaut.
Récupération après une coupure d’électricité
En cas de coupure d’électricité, le variateur mémorise son dernier état de
fonctionnement. Lorsque l’alimentation est restaurée, si le variateur était en
marche, il retrouve automatiquement et progressivement le niveau qui était
le sien au moment de la coupure, à raison de 20 %/seconde.
NOTAS IMPORTANTES:
1. Todos los reguladores pueden dañarse si se cablean incorrectamente.
Verifique si hay cortocircuitos antes de instalar el regulador con una
carga de lámpara en el circuito.
Procedimiento para la vericación de cortocircuitos:
a. Quite el fusible o apague los disyuntores para interrumpir el suministro
eléctrico al circuito.
b. Instale un interruptor en lugar del regulador. Coloque el interruptor en
la posición de encendido.
c. Encienda la alimentación. Si el disyuntor se dispara, existe una
condición de cortocircuito. Si la luz no se enciende y se apaga con el
interruptor, es posible que el cableado no esté correctamente tendido.
d. Corrija el cableado, de ser necesario, y vuelva a probar.
e. Instale el regulador solo después de que la luz funcione correctamente
junto con el interruptor.
2. Proteja este producto contra el polvo y la suciedad. Es posible que el
regulador esté dañado a causa de contaminantes presente durante el
proceso de construcción. Si es preciso realizar la iluminación antes de
finalizar el proceso de construcción, debe instalarse temporalmente un
interruptor en lugar de este producto. Este producto no debe instalarse
hasta que finalice el proceso de construcción.
La garantía no cubre los daños al regulador resultantes de una
instalación incorrecta.
INSTRUCCIONES
1. Si se proporcionó un juego de cambio de color, y se desea un color
diferente, consulte el Procedimiento de cambio de color, (Figura 1); de lo
contrario, continúe con el paso n.º2.
2. Quite el fusible o coloque el disyuntor en la posición de apagado para
interrumpir el suministro eléctrico al circuito.
3. Quite los tornillos de montaje del interruptor y la placa de pared; extraiga
el interruptor existente de la caja de pared.
4. Desconecte el interruptor existente del circuito. Para las instalaciones
de 3 vías existentes: Identifique el cable “común” (cable conectado a
la terminal marcada como común; es posible que esta terminal sea de
un color diferente). Para las instalaciones nuevas, identifique el cable
conectado a la fuente de alimentación o la carga.
5. Conecte el regulador como se muestra en el diagrama de instalación
correspondiente usando conductores de cobre calibre 12 o 14 AWG
sólidos o trenzados. Tenga en cuenta que las posiciones remotas y del
regulador pueden ser inversas de las que se muestran. Pele el cable
hasta la longitud que se muestra en la parte trasera del producto.
6. Con los tornillos de montaje provistos, instale el producto en la caja de
pared, de modo tal que la palabra “Top” que está en la correa quede
con el lado derecho hacia arriba.
7. Conecte la placa de pared y, luego, reconecte el suministro eléctrico a la
unidad.
8. Es posible que el regulador deba ajustarse a la configuración del
extremo bajo para que se inicie de manera fiable y/o elimine el parpadeo
en las bombillas. Implemente los ajustes necesarios según se detallan
en la sección “Parámetros ajustables por el usuario” de la sección
FUNCIONAMIENTO DEL ATENUADOR.
NOTA: Es normal que el regulador se sienta tibio al tacto mientras está
funcionando. Use un cable neutro individual para cada fase de un sistema
multifásico que contenga un regulador y para las aplicaciones de una sola
fase de alta potencia donde hay una titilación presente.
Se puede unir cualquier combinación de modelos de atenuadores y otros
dispositivos. Reduzca la capacidad normal de carga máxima de acuerdo
con la siguiente tabla:
Carga nominal Instalación de 3 juegos (o más)
Incd./Hal. 700W 650W
MLV 700VA 650VA
CLF/LED 450W 450W
Instalación unipolar
1. NOTA: Los colores de cable indicados son los del dispositivo solamente,
no los cables de la caja de pared. Asegúrese de probar los cables de la
caja de pared antes de hace cualquier conexión.
2. Conecte el dispositivo siguiendo el diagrama de cableado unipolar que
se muestra.
Instalacn de tres vías
1. NOTA: Las aplicaciones de tres vías o de múltiple ubicación requieren
que se use un HMR remoto de múltiple ubicación junto con un regulador
preestablecido. No debe usarse un interruptor de tres vías regular para
controlar un regulador de múltiple ubicación. Esto puede dañar el control
y, a la vez, anular la garantía de la unidad.
Consulte las Figuras de la 2 a la 5 del diagrama.
FUNCIONAMIENTO
Descripción general de la interfaz del usuario
La interfaz del usuario del regulador consta de
lo siguiente:
[1] LED de ubicación
[2] Botón de encendido/apagado
[3] Gráfico de barras LED de siete
elementos
[4] Interruptor de espacio de aire
[5] Botones basculantes para
aumentar/disminuir
Indicadores LED
Carga apagada: cuando el regulador recibe alimentación, pero
la carga está apagada, el LED de ubicación [1] estará en la intensidad
completa (si está activado) y todos los LED del gráfico de barras [3]
estarán apagados.
Carga encendida: cuando el regulador esté haciendo funcionar la carga
(carga encendida), el LED de ubicación [1] estará apagado y el gráfico de
barras [3] se iluminará comenzando desde la parte inferior para indicar el
nivel de brillo de carga presente.
Modos de configuración: la función de los LED varía con cada modo de
configuración específico y se detallará en dichas descripciones.
Botón de encendido/apagado [2]
Presionar momentáneamente el botón de encendido/apagado con la
carga apagada hace que la carga se encienda gradualmente al LDL
(nivel de graduación de la luz) de 50 %/segundo.
Presionar momentáneamente el botón de encendido/apagado con la
carga encendida hace que la carga se apague gradualmente a una
velocidad del 50 %/segundo (desde totalmente encendida; tardará 2
segundos en apagarse).
Presionar y mantener presionado el botón de encendido/apagado
durante aproximadamente 2 segundos con la carga encendida haca
que la carga se apague gradualmente en aproximadamente 30
segundos (función “ir a la cama”). Durante el intervalo de apagado
gradual lento, el LED más brillante en el gráfico de barras parpadeará a
aproximadamente 3 Hz (3 veces por segundo).
Tocar dos veces el botón de encendido/apagado con la carga encendida
hace que la carga se encienda hasta el nivel máximo de brillo a una
velocidad del 50 %/segundo.
Botón basculante para aumentar (+) [5]
Presionar momentáneamente con la carga encendida aumenta el brillo
1 punto (aprox. 7 % del brillo máximo).
Presionar y mantener presionado durante más de 0,5 segundo con la
carga encendida aumenta rápidamente el brillo a una velocidad del
20 %/segundo (aprox. 5 segundos del brillo mínimo al máximo).
Botón basculante para disminuir (-) [5]
Presionar momentáneamente con la carga encendida reduce el brillo
1 punto (aprox. 7 % del brillo máximo).
Presionar y mantener presionado durante más de 0,5 segundo con la
carga encendida disminuye rápidamente el brillo a una velocidad del
20 %/segundo (aprox. 5 segundos del brillo máximo al mínimo).
Interruptor de espacio de aire [4]
Deslice a la posición de apagado antes de reemplazar la carga. Deslice
a la posición de encendido después de haber reemplazado la carga.
PARÁMETROS AJUSTABLES POR EL USUARIO
Nivel mínimo de corte
Mantenga presionado el botón basculante para disminuir (-) [5] durante
aproximadamente 10 segundos después de alcanzar el brillo mínimo.
Los LED del gráfico de barras se encienden para indicar que se activó el
modo de calibración.
Presionar el botón de encendido/apagado [2] alterna entre 12 niveles de
corte preestablecidos, que se muestran en el gráfico de barras.
Presionar el botón basculante para aumentar o el botón basculante para
disminuir [5] desactiva el modo de calibración y guarda el nivel de corte
seleccionado.
El valor predeterminado del nivel de corte mínimo se establece en un nivel
adecuado para permitir un funcionamiento estable de una carga LED típica.
Nivel máximo de corte (ahorro de enera)
Mantenga presionado el botón basculante para aumentar (+) [5] durante
aproximadamente 10 segundos después de alcanzar el brillo máximo.
Los LED del gráfico de barras se encienden para indicar que se activó el
modo de calibración.
Presionar el botón de encendido/apagado [2] alterna entre 12 niveles de
corte preestablecidos, que se muestran en el gráfico de barras.
Presionar el botón basculante para aumentar o el botón basculante
para disminuir desactiva el modo de calibración y guarda el nivel de
corte seleccionado.
El valor predeterminado para el nivel de corte máximo es 100 %.
Activar/Desactivar el LED de ubicacn [1]
Presionar y mantener presionado el botón de encendido/apagado [2]
durante aproximadamente 10 segundos con la carga apagada, hasta
que el LED de ubicación titile una vez a modo de confirmación, desactiva
el funcionamiento del LED de ubicación cuando la carga está apagada.
Continuar presionando el botón otros 2 segundos (12 segundos en total),
hasta que el LED de ubicación titile dos veces a modo de confirmación,
activa el funcionamiento del LED de ubicación.
Restablecimiento a los ajustes de fábrica
Con la unidad apagada, presione y mantenga presionado el botón de
encendido/apagado [2] durante 15 segundos. Los LED del gráfico de
barras y de ubicación titilarán 3 veces para indicar que los niveles de corte
mínimo y máximo y los parámetros del LED de ubicación se restablecieron
en los valores predeterminados.
Recuperación tras una falla de alimentación
En el caso de una falla de alimentación, el regulador guarda el último
estado de funcionamiento en la memoria. Cuando la alimentación se
restaura, si el regulador estaba encendido, este automáticamente se
establecerá en el nivel en el que estaba en el momento de la falla de
alimentación, a una velocidad del 20 %/segundo.
INSTRUCTIONS EN FRANÇAIS
INSTRUCCIONES EN ESPAÑOL

Transcripción de documentos

Pass & Seymour ® Harmony® Multilocation Dimmer; Ratings: Incandescent: 700W; CFL, LED: 450W; MLV 700VA Harmony® Variateur à multilocalisation ; Puissance nominale : à incandescence ; 700 W ; lampe fluo-compacte, DEL : 450 W ; transformateur 700 VA Regulador de ubicación múltiple Harmony®; especificaciones: Incandescente: 700 W; CFL, LED: 450 W; MLV 700 VA No: 341102 – 01/15 Installation Instructions • Notice d’Installation • Instrucciones de Instalación Catalog Number(s) • Numéro(s) de catalogue • Número(s) de catálogo: HCL453PMM and HMR Country of Origin: Made in China • Pays d’origine : Fabriqué en Chine • País de origen: Hecho en China READ AND SAVE THESE INSTRUCTIONS To be installed by a certified electrician or other qualified person. WARNING: To prevent severe shock or electrocution, always turn power off at the service panel before installing this product, working on the circuit or changing a lamp. CAUTION • To reduce the risk of overheating and possible damage to this product or other equipment do not use this product to control a receptacle, a motor operated appliance or a transformer based appliance. • Do not use this product with loads whose power requirements exceed the maximum power (stated in watts, amperes or volt-amperes) of the dimmer. • Use only with incandescent, compatible dimmable CFL/LED bulbs which screw into conventional incandescent lamp sockets, or MLV loads (compatible bulbs listed at www.legrand.us). • A 5 watt minimum load is required. • Do not connect this product to a power source other than 120VAC, 60Hz. • Use copper wire only. • Always slide the Air Gap Switch to the full down (OFF) position when changing a light bulb. • For MLV loads: - The maximum VA rating of this dimmer applies to the transformer input of the MLV, not the load connected to the transformer secondary of the MLV. - Do not use to control a solid state electronic low voltage transformer. - Do not use with inoperative or missing lamps. Use of this dimmer with inoperative or missing lamps can create an over current condition which may damage the transformer. Use transformers that incorporate thermal protection or a fuse at the primary windings. HCL453PMM HMR IMPORTANT NOTES: 1. All dimmers can be damaged by improper wiring. Check for short circuits prior to installing the dimmer with a lamp load in the circuit. Procedure for short circuit check: a. Disconnect power to circuit by removing fuse or turn circuit breakers OFF. b. Install a switch instead of the dimmer. Turn the switch to the ON position. c. Turn power ON. If the circuit breaker trips, a short circuit is present. If the light fails to turn ON and OFF with the switch, the wiring may be incorrect. d. Correct wiring, if necessary, and retest. e. Install the dimmer only after the light operates properly with the switch. 2. Protect this product from dust and dirt. The dimmer can be damaged by contaminates encountered during the construction process. If lighting is required prior to the construction process completion, then a switch should be temporarily installed in place of this product. This product should not be installed until the construction process is complete. Any dimmer damage due to improper installation is not covered under warranty. DIRECTIONS 1. 2. 3. 4. 5. 6. 1. If color change kit was provided, and a different color is desired, see the Color Change Procedure, (Figure 1), if not proceed to step #2. 2. Disconnect power to the circuit by removing the fuse or turning the circuit breaker to the off position. 3. Remove wall plate and switch mounting screws, pull existing switch from wall box. 4. Disconnect existing switch from circuit. For existing 3-way installations: identify the “Common” wire (wire connected to the terminal marked common, this terminal may also be of a different color). For new installation identify wire connected to power source or load. 5. Connect dimmer as shown in the applicable installation diagram using #12 or #14 AWG wire stranded or solid copper conductors. Note that the dimmer and remote positions may not be reversed from that shown. Strip the wire to the length shown on the back of the product. 6. Install product in wall box, with the word “Top” on the strap right side up, using mounting screws provided. 7. Attach wall plate and then restore power to the unit. 8. The dimmer may require adjustment to the low end setting to reliably start and/or remove flickering in bulbs. Make adjustment as stated in the “User Adjustable Parameters” section of the DIMMER OPERATION section. NOTE: It is normal for the dimmer to feel warm during operation. Use a separate neutral wire for each phase of a multiphase system containing a dimmer, and for high power single phase applications where flickering is present. Any combination of dimmer models and other devices may be ganged together. De-rate the maximum load according to the following table: Rated Load 700W 700VA 450W LEA Y GUARDE ESTAS INSTRUCCIONES La instalación debe estar a cargo de un electricista certificado u otra persona calificada. ADVERTENCIA: Para evitar una fuerte descarga eléctrica o la electrocución, siempre desconecte el suministro eléctrico en el panel de servicio antes de instalar este producto, trabajar en el circuito o cambiar una lámpara. PRECAUCIÓN • Para reducir el riesgo de sobrecalentamiento y posibles daños a este producto u otros equipos, no use este producto para controlar un receptáculo, un dispositivo accionado por motor o un dispositivo con transformador. • No use este producto con cargas cuyos requisitos de potencia superen la potencia máxima (expresada en vatios, amperios o voltio-amperios) del regulador. • Úselo solo con bombillas CFL/LED incandescentes regulables compatibles que se inserten en casquillos para lámparas incandescentes convencionales o con cargas MLV (bombillas compatibles detalladas en www.legrand.us). • Se requiere una carga mínima de 5 W. • No conecte este producto a una fuente de alimentación que no sea de 120 V AC, 60 Hz. • Use solamente cables de cobre. • Siempre deslice el interruptor de espacio de aire a la posición totalmente hacia abajo (apagado) al cargar una bombilla. • Para las cargas MLV: - La capacidad nominal máxima de VA de este regulador corresponde a la entrada del transformador de MLV, no a la carga conectada al transformador secundario del MLV. - No lo use para controlar un transformador de bajo voltaje electrónico de estado sólido. - No lo use con lámparas defectuosas o faltantes. El uso del regulador con lámparas defectuosas o faltantes puede crear una condición de corriente en exceso que puede dañar el transformador. Use los transformadores que tienen protección térmica o un fusible en los arrollamientos primarios. Single-Pole Installation LOWER Rocker button (-) [5] Three-Way Installation Air gap switch [4] 1. NOTE: Wire colors indicated are those of the device only, not the wires in the wall box. Be sure to test wall box wires before making any connections. 2. Connect the device following the single-pole wiring diagram shown. • Momentary push with Load ON decreases brightness 1 increment (approx 7% of max brightness). • Push and hold for more than 0.5 seconds with load ON ramps brightness down at 20%/second (approx 5 sec from max to min). 1. NOTE: Three-way or multi-location applications require the use of a MultiLocation Remote HMR, in conjunction with a Preset Dimmer. A regular three-way switch should not be used to control a Multi-Location Dimmer. Doing so may damage the control and, in turn, void the unit’s warranty. See Wiring Diagram Figures 2-5 below. • Slide to OFF position before replacing load. Slide to ON position after load has been replaced. USER-ADJUSTABLE PARAMETERS Min Level Trim OPERATION User Interface – Overview The user interface of the dimmer consists of: [1] Locator LED [2] ON/OFF Pushbutton [3] Seven-Element LED Bar Graph [4] Air Gap Switch [5] RAISE/LOWER Rocker buttons • Hold LOWER Rocker button (-) [5] down for approximately 10s after minimum brightness reached. Bar graph LEDs will flash to indicate calibration mode activated. • Pressing ON/OFF pushbutton [2] cycles through 12 preset trim levels, which are displayed on the bar graph. • Pressing either the Raise or Lower rocker button [5] exits calibration and stores selected trim level. The default value for the min level trim is set to a level adequate for stable operation of a typical LED load. LED Indicators Max Level Trim (energy saver) ON/OFF Pushbutton [2] Disable/Enable Locator LED [1] • Hold RAISE Rocker button (+) [5] down for approximately 10s after maximum brightness reached. Bar graph LEDs will flash to indicate cal mode activated. • Pressing ON/OFF pushbutton [2] cycles through 12 preset trim levels, which are displayed on the bar graph. • Pressing either Raise or Lower rocker pushbuttons exits calibration and stores selected trim level. The default value for the max level trim is 100%. Load Off – When the dimmer is powered, but the load is OFF, the locator LED [1] will be on at the full intensity (if enabled), and all LEDs in the bar graph [3] will be off. Load On – When the dimmer is operating the load (load ON), the locator LED [1] will be off, and the bar graph [3] will be illuminated starting from the bottom, to indicate the present load brightness level. Setup Modes – The function of the LEDs varies with each specific setup mode, and will be detailed in those descriptions. Figure 1 / Figure 1 / Figura 1 Incd./Hal. MLV CLF/LED LISEZ ET CONSERVEZ CES INSTRUCTIONS Ce dispositif doit être installé par un électricien certifié ou une autre personne qualifiée. AVERTISSEMENT : afin d’éviter tout choc électrique ou électrocution grave, toujours éteindre l’alimentation sur le panneau de service avant d’installer ce produit, de travailler sur le circuit ou de changer une lampe. MISE EN GARDE : • Pour réduire le risque de surchauffe et d’autres dommages possibles sur ce produit ou d’autres appareils, ne pas utiliser ce produit pour contrôler une prise électrique, un appareil à moteur ou un appareil avec transformateur. • Ne pas utiliser ce produit avec des ampoules dont les besoins en énergie dépassent la puissance maximale (exprimée en watts, en ampères ou en voltampères) du variateur. • Utiliser uniquement ce produit avec des ampoules compatibles, à incandescence, fluo-compactes/DEL, à intensité réglable, pouvant être vissées dans des douilles conventionnelles pour ampoules à incandescence, ou des charges de transformateur (ampoules compatibles répertoriées sur le site www.legrand.us). • Une ampoule d’au moins 5 watts est requise. • Ne brancher ce produit qu’à une source d’alimentation de 120 V c.a., 60 Hz. • N’utilisez que des fils en cuivre. • Au moment de changer l’ampoule, faire glisser l’interrupteur Air Gap jusque dans sa position la plus basse (OFF). • Pour les charges de transformateur : - La capacité maximale en VA de ce dispositif s’applique à l’entrée du transformateur et non pas à la charge au niveau de la partie secondaire du transformateur. - Ne pas s’en servir pour commander un transformateur électronique basse tension à semi-conducteurs. - N’utilisez pas ce dispositif avec des lampes défaillantes ou manquantes. L’utilisation de cette unité avec des lampes défaillantes ou manquantes peut créer une situation de surintensité qui risque d’endommager le transformateur. Utilisez des transformateurs équipés d’une protection thermique ou d’un fusible au niveau des enroulements primaires. Holding the ON/OFF pushbutton [2] down for approximately 10s with load OFF, until Locator LED flashes once in confirmation, disables operation of the Locator LED when load is off. Continuing to hold the button for an additional 2s (12s total), until the Locator LED flashes twice in confirmation, enables the Locator LED operation. • Momentary push of ON/OFF button with Load OFF fades load on to LDL (last dim level) at 50%/second. • Momentary push of ON/OFF button with Load ON fades load off at a rate of 50%/second (from full on, it will take 2 sec to off). • Push and hold of ON/OFF button for approximately 2s with load ON fades load off over approximately 30s (“go to bed” feature). During the slow fade-off interval the top-most lit LED in the bar graph will flash at approximately 3Hz (3 times per second). • Double-tap of ON/OFF button with Load ON fades load to maximum brightness at 50%/second. Factory Reset With the unit in the OFF state, hold down the ON/OFF pushbutton [2] for 15 seconds. The bar graph and locator LEDs will flash 3 times to indicate that the minimum and maximum trim levels and locator LED parameters have been reset to defaults. RAISE Rocker button (+) [5] Power Failure Recovery • Momentary push with Load ON increases brightness 1 increment (approx. 7% of max brightness). • Push and hold for more than 0.5 seconds with Load ON ramps brightness up at 20%/second (approx 5 sec from min to max). In the case of a power failure, the dimmer saves its last operating state to memory. When power is restored, if the dimmer load was on, the dimmer will automatically fade, at 20%/second rate, to the level at the time of the power failure. WIRING DIAGRAMS / SCHÉMAS DE CÂBLAGE / DIAGRAMAS DE CABLEADO Single Location Control (Using Existing Single Pole Switch Wiring) Contrôle de localisation unique (à l’aide du câblage de commutation unipolaire existant) Control de una sola ubicación (con el cableado del interruptor unipolar existente) DIMMER / VARIATEUR / REGULADOR Borne marquée télécommandée. La vis rouge n’est pas utilisée. Terminal etiquetada para el dispositivo remoto. El tornillo rojo no se usa. 3 Gang (or more) Installation 650W 650VA 450W Green Wire Fil vert Cable verde Ground Tierre Tierra DIMMER / VARIATEUR / REGULADOR Line (Hot/Black) Wire Noir – Câble secteur/Sous tension Terminal Labeled Hot - Black Screw Borne marquée chaude - Vis noire Terminal etiquetada para el conductor vivo; tornillo negro Terminal Labeled Remote. Red Screw Is Not Used. Two Location Control (Using Existing 3-Way Switch Wiring) Contrôle de localisation double (à l’aide du câblage de commutation à trois voies existant) Control de dos ubicaciones (con el cableado del interruptor de 3 vías existente) Line (Hot/Black) Wire Borne marquée chaude - Vis noire Cable de línea (vivo/negro) 120VAC 60Hz 120 VCA, Load 60 Hz Terminal Charge 120 V CA, Labeled Load Carga 60 Hz Brass Screw Borne marquée charge - Vis en laiton Neutral (White) Wire Terminal Fil neutre (blanc) etiquetada para la carga; Cable neutro (blanco) tornillo de latón Cable de línea (vivo/negro) Terminal Labeled Remote Red Screw Borne marquée télécommandée – Vis rouge Terminal etiquetada para el dispositivo remoto; tornillo rojo REMOTE / TÉLÉCOMMANDE / DISPOSITIVO REMOTO Terminal Labeled Remote Red Screw Borne marquée télécommandée – Vis rouge Terminal etiquetada para el dispositivo remoto; tornillo rojo Terminal Labeled Load Brass Screw Borne marquée charge – Vis en laiton Terminal etiquetada para la carga; tornillo de latón Terminal Labeled Hot, Black Screw Borne marquée chaude – Vis noire Terminal etiquetada para el conductor vivo; tornillo negro Traveler Wire #2 Fil mobile n° 2 Cable puente n.º 2 120VAC 60Hz 120 VCA, 60 Hz 120 V CA, 60 Hz Green Wire Fil vert Cable verde Ground Tierre / Tierra Load Charge Carga Terminal Labeled Load Brass Screw Borne marquée charge – Vis en laiton Terminal etiquetada para la carga; tornillo de latón Ground Tierre Tierra Traveler Wire #1 / Fil mobile n° 1 / Cable puente n.º 1 Green Wire Fil vert Cable verde Neutral (White) Wire / Fil neutre (blanc) / Cable neutro (blanco) Figure 2 / Figure 2 / Figura 2 Two or More Location Control (Up to 9 Remotes) Wiring Option B: Connecting Remote To Neutral Contrôle de localisation double ou davantage (jusqu’à 9 télécommandes) Option de câblage B : Raccordement de la télécommande au neutre Opción de cableado B para control de dos o más ubicaciones (hasta 9 dispositivos remotos): Conexión de dispositivo remoto a neutro Two or More Location Control (Up to 9 Remotes) Wiring Option A: Connecting Load Through Remotes Contrôle de localisation double ou davantage (jusqu’à 9 télécommandes) Option de câblage A : Raccordement d’une charge par le biais de télécommandes Opción de cableado A para control de dos o más ubicaciones (hasta 9 dispositivos remotos) A: Conexión de la carga a través de dispositivos remotos DIMMER / VARIATEUR / REGULADOR Line (Hot/Black) Wire Noir – Câble secteur/Sous tension Cable de línea (vivo/negro) Terminal Labeled Remote Red Screw Borne marquée télécommandée – Vis rouge Terminal etiquetada para el dispositivo remoto; tornillo rojo Terminal Labeled Remote Red Screw Borne marquée télécommandée – Vis rouge Terminal etiquetada para el dispositivo remoto; tornillo rojo REMOTE / TÉLÉCOMMANDE / DISPOSITIVO REMOTO Traveler Wire #2 Fil mobile n° 2 Cable puente n.º 2 Ground Tierre / Tierra Terminal Labeled Load Brass Screw Borne marquée charge – Vis en laiton Terminal etiquetada para la carga; tornillo de latón Traveler Wire #1 / Fil mobile n° 1 / Cable puente n.º 1 Load Charge Carga Green Wire Fil vert Cable verde Terminal Labeled Load Brass Screw Borne marquée charge – Vis en laiton Terminal etiquetada para la carga; tornillo de latón Neutral (White) Wire / Fil neutre (blanc) / Cable neutro (blanco) Figure 4 / Figure 4 / Figura 4 Ground Tierre Tierra Green Wire Fil vert Cable verde REMOTE / TÉLÉCOMMANDE / DISPOSITIVO REMOTO DIMMER / VARIATEUR / REGULADOR Terminal Labeled Remote Red Screw Borne marquée télécommandée – Vis rouge Terminal etiquetada para el dispositivo remoto; tornillo rojo Terminal Labeled Load Brass Screw Borne marquée charge – Vis en laiton Terminal etiquetada para la carga; tornillo de latón Terminal Labeled Hot, Black Screw Borne marquée chaude – Vis noire Terminal etiquetada para el conductor vivo; tornillo negro 120VAC 60Hz 120 VCA, 60 Hz 120 V CA, 60 Hz Green Wire Fil vert Cable verde REMOTE / TÉLÉCOMMANDE / DISPOSITIVO REMOTO Figure 3 / Figure 3 / Figura 3 Line (Hot/Black) Wire Noir – Câble secteur/Sous tension Cable de línea (vivo/negro) Terminal Labeled Remote Red Screw Borne marquée télécommandée – Vis rouge Terminal etiquetada para el dispositivo remoto; tornillo rojo Terminal Labeled Hot, Black Screw Borne marquée chaude – Vis noire Terminal etiquetada para el conductor vivo; tornillo negro 120VAC 60Hz 120 VCA, 60 Hz 120 V CA, 60 Hz Green Wire Fil vert Cable verde Terminal Labeled Remote Red Screw Borne marquée télécommandée – Vis rouge Terminal etiquetada para el dispositivo remoto; tornillo rojo Terminal Labeled Remote Red Screw Borne marquée télécommandée – Vis rouge Terminal etiquetada para el dispositivo remoto; tornillo rojo Load Charge Carga ! Terminal Labeled Load Brass Screw Borne marquée charge – Vis en laiton Terminal etiquetada para la carga; tornillo de latón * Green Wire Fil vert Cable verde Neutral (White) Wire / Fil neutre (blanc) / Cable neutro (blanco) Ground Tierre / Tierra REMOTE / TÉLÉCOMMANDE / DISPOSITIVO REMOTO * Ground Tierre Tierra Terminal Labeled Load Brass Screw Borne marquée charge – Vis en laiton Terminal etiquetada para la carga; tornillo de latón Ground Tierre Tierra *Either load terminal can be used / *N’importe quelle borne de charge peut être utilisée / *Se puede usar cualquier terminal de carga. Figure 5 / Figure 5 / Figura 5 Green Wire Fil vert Cable verde INSTRUCTIONS EN FRANÇAIS REMARQUES IMPORTANTES 1. Tous les variateurs peuvent être endommagés en cas de câblage incorrect. Vérifiez qu’il n’y a pas de court-circuit avant d’installer le variateur sur une ampoule dans le circuit. Procédure pour la recherche de court-circuit : a. Déconnectez l’alimentation du circuit en retirant un fusible ou en mettant les disjoncteurs sur OFF (Arrêt). b. Installez un interrupteur plutôt qu’un variateur. Mettez l’interrupteur en position ON (Marche). c. Mettez le courant en marche. Si le disjoncteur se déclenche, il existe un court-circuit. Si la lumière ne s’allume et ne s’éteint pas avec l’interrupteur, le câblage est probablement incorrect. d. Corrigez le câblage si nécessaire puis retestez. e. N’installez le variateur qu’une fois que la lumière fonctionne correctement avec l’interrupteur. 2. Protégez ce produit de la poussière et de la saleté. Le variateur peut être endommagé s’il est exposé à des éléments contaminants au cours du processus de construction. Si un éclairage est requis avant la fin du processus de construction, un interrupteur doit alors être installé temporairement à la place du variateur. Ce produit ne doit être installé qu’une fois le processus de construction terminé. Les dommages au variateur engendrés par une mauvaise installation ne sont pas couverts par la garantie. INSTRUCTIONS 1. Si une trousse de changement de couleur est fournie et que vous souhaitez changer de couleur, consultez la Procédure de changement de couleur (figure 1). Sinon, passez directement à l’étape 2. 2. Déconnectez l’alimentation du circuit en retirant un fusible ou en mettant les disjoncteurs sur OFF. 3. Retirez la plaque murale et les vis de fixation de l’interrupteur, puis retirez l’interrupteur existant du boîtier mural. 4. Déconnectez l’interrupteur existant du circuit. Pour les installations à 3 voies existantes : identifiez le fil commun (fil connecté à la borne portant le marquage correspondant. Cette borne est parfois d’une autre couleur). Pour de nouvelles installations, identifiez le fil connecté à la source d’alimentation ou à l’ampoule. 5. Connectez le variateur tel qu’illustré dans le schéma d’installation en utilisant des fils multibrins de 2,05 ou 1,63 mm de diamètre ou de solides conducteurs en cuivre. Veuillez noter que le variateur et les 3 positions de l’interrupteur peuvent également être inversés par rapport à ce qui est illustré. Dénudez le fil sur la longueur indiquée au dos du produit. 6. À l’aide des vis de fixation fournies, installez le produit dans le boîtier mural en plaçant le côté droit de la sangle où figure le mot « Haut » vers le haut. 7. Fixez la plaque murale puis restaurez l’alimentation de l’unité. 8. Le variateur peut nécessiter un ajustement des réglages minimum pour pouvoir démarrer en toute fiabilité et/ou stopper les vacillements des ampoules. Veuillez suivre les indications fournies dans le paragraphe « Ajustements par l’utilisateur » de la section « FONCTIONNEMENT DU VARIATEUR ». REMARQUE : Il est normal que le variateur soit légèrement chaud durant son fonctionnement. Utilisez un fil neutre différent pour chaque phase d’un système multiphase contenant un variateur et pour les applications monophases haute puissance en présence de vacillements. Dans le cas d’une utilisation de plusieurs modèles de variateurs et d’autres appareils, ces derniers peuvent être raccordés ensemble. Déclasser la charge maximum selon le tableau suivant : Charge nominale 700W 700VA 450W Incd./Hal. MLV CLF/LED Installation triple (ou plus) 650W 650VA 450W Installation unipolaire 1. REMARQUE : Les fils indiqués en couleur sont ceux de l’appareil uniquement et non ceux du boîtier mural. Avant tout raccordement, veillez à tester les fils du boîtier mural. 2. Connectez l’appareil conformément au schéma de câblage unipolaire illustré. Installation à trois voies 1. REMARQUE : Les applications à trois voies ou à multilocalisation nécessitent de recourir à une télécommande à multilocalisation HMR, associé à un variateur préréglé. N’utilisez pas d’interrupteur à trois voies normal pour commander le variateur à multilocalisation. Vous risqueriez ainsi d’endommager la commande et d’annuler la garantie de l’unité. Voir le schéma de câblage, figures 2-5. FONCTIONNEMENT Vue d’ensemble de l’interface utilisateur L’interface utilisateur du variateur se compose des éléments suivants : [1] DEL du dispositif de localisation [2] Bouton poussoir ON/OFF [3] G  raphique à barres des DEL à sept éléments [4] Interrupteur Air Gap [5] Touches à bascule LEVER/BAISSER Voyants DEL Lumière éteinte – Lorsque le variateur est alimenté, mais que la lumière est éteinte, la DEL du dispositif de localisation [1] est allumée à pleine puissance (en cas d’activation), et toutes les DEL du graphique à barres [3] sont éteintes. Lumière allumée – Lorsque le variateur commande la charge (lumière allumée), la DEL du dispositif de localisation [1] est éteinte, et le graphique à barres [3] s’allume en commençant par le bas afin d’indiquer le niveau de luminosité de charge en présence. Modes de configuration – Le fonctionnement des DEL varie selon le mode de configuration et est détaillé dans ces descriptions. Bouton poussoir ON/OFF [2] • Lorsque la lumière est éteinte, pour l’allumer progressivement jusqu’au niveau LDL (dernier niveau de réglage) à raison de 50 %/seconde, appuyer rapidement sur le bouton ON/OFF. • Lorsque la lumière est allumée, pour l’éteindre progressivement à un rythme de 50 %/seconde (de pleinement activée, il lui faudra 2 s pour s’éteindre), appuyer rapidement sur le bouton ON/OFF. • Si l’on appuie sur le bouton ON/OFF et qu’on le maintient enfoncé pendant env. 2 s avec la lumière allumée, celle-ci s’éteint progressivement en environ 30 s (fonction de « mise au lit »). Pendant cet intervalle d’extinction progressive lente, la DEL du haut dans le graphique à barres clignote à environ 3Hz (3 fois par seconde). • Lorsque la lumière est allumée, pour augmenter progressivement le degré jusqu’à atteindre la luminosité maximale à 50 %/seconde, appuyer deux fois sur le bouton ON/OFF. Touche à bascule LEVER (+) [5] • Pour augmenter la luminosité d’un palier (environ 5 % de la luminosité maximale), appuyer rapidement sur le haut de la palette lorsque la lumière est allumée. • Si l’on appuie sur le bouton et qu’on le maintient enfoncé pendant plus de 0,5 seconde avec la lumière allumée, la luminosité augmente à raison de 20 %/seconde (env. 5 s pour passer du niveau min. au niveau max.). Touche à bascule BAISSER (-) [5] • Pour diminuer la luminosité d’un palier (environ 5 % de la luminosité maximale), appuyer rapidement sur le bas de la palette lorsque la lumière est allumée. • Si l’on appuie sur le bouton et qu’on le maintient enfoncé pendant plus de 0,5 seconde avec la lumière allumée, la luminosité diminue à raison de 20 %/seconde (env. 5 s pour passer du niveau min. au niveau max.). Interrupteur Air Gap [4] • Faire glisser en position OFF avant de remplacer la charge. Faire glisser en position ON une fois la charge remplacée. PARAMÈTRES RÉGLABLES PAR L’UTILISATEUR Réglage du niveau minimum • Maintenir la touche à bascule BAISSER (-) [5] enfoncée pendant environ 10 s une fois le niveau de luminosité minimal atteint. Les DEL du graphique à barres clignotent pour indiquer que le mode d’étalonnage est activé. • Appuyer sur le bouton poussoir ON/OFF [2] pour passer d’un niveau de réglage à l’autre parmi les 12 qui sont prédéfinis et affichés dans le graphique à barres. • Appuyer sur la touche à bascule LEVER ou ABAISSER [5] pour quitter le mode d’étalonnage et enregistrer le niveau de réglage sélectionné. La valeur par défaut du réglage de niveau min. est définie sur un niveau permettant d’assurer le fonctionnement stable d’une charge de DEL normale. Ajustement du niveau maximum (éco-énergétique) • Maintenir la touche à bascule LEVER (+) [5] enfoncée pendant env. 10 s une fois le niveau de luminosité de luminosité atteint. Les DEL du graphique à barres clignotent pour indiquer que le mode d’étalonnage est activé. • Appuyer sur le bouton poussoir ON/OFF [2] pour passer d’un niveau de réglage à l’autre parmi les 12 qui sont prédéfinis et affichés dans le graphique à barres. • Appuyer sur le bouton poussoir Lever ou Baisser pour quitter le mode d’étalonnage et enregistrer le niveau de réglage sélectionné. La valeur par défaut du réglage de niveau max. est de 100 %. Désactiver/activer la DEL du dispositif de localisation [1] Maintenir le bouton poussoir ON/OFF [2] enfoncé pendant environ 10 s alors que la lumière est éteinte jusqu’à ce que la DEL du dispositif de localisation clignote une fois en guise de confirmation, et désactive la DEL du dispositif de localisation lorsque la lumière est éteinte. Maintenir encore le bouton enfoncé pendant 2 s supplémentaires (12 s au total) jusqu’à ce que la DEL du dispositif de localisation clignote deux fois en guise de confirmation, et active la DEL du dispositif de localisation. Réinitialisation Lorsque l’unité est éteinte, maintenir le bouton poussoir ON/OFF [2] enfoncé pendant 15 secondes. Les DEL du graphique à barres et du dispositif de localisation clignotent 3 fois pour indiquer que les niveaux de réglage minimum et maximum, et les paramètres des DEL du dispositif de localisation ont été réinitialisés sur leurs valeurs par défaut. Récupération après une coupure d’électricité En cas de coupure d’électricité, le variateur mémorise son dernier état de fonctionnement. Lorsque l’alimentation est restaurée, si le variateur était en marche, il retrouve automatiquement et progressivement le niveau qui était le sien au moment de la coupure, à raison de 20 %/seconde. INSTRUCCIONES EN ESPAÑOL NOTAS IMPORTANTES: 1. Todos los reguladores pueden dañarse si se cablean incorrectamente. Verifique si hay cortocircuitos antes de instalar el regulador con una carga de lámpara en el circuito. Procedimiento para la verificación de cortocircuitos: a. Quite el fusible o apague los disyuntores para interrumpir el suministro eléctrico al circuito. b. Instale un interruptor en lugar del regulador. Coloque el interruptor en la posición de encendido. c. Encienda la alimentación. Si el disyuntor se dispara, existe una condición de cortocircuito. Si la luz no se enciende y se apaga con el interruptor, es posible que el cableado no esté correctamente tendido. d. Corrija el cableado, de ser necesario, y vuelva a probar. e. Instale el regulador solo después de que la luz funcione correctamente junto con el interruptor. 2. Proteja este producto contra el polvo y la suciedad. Es posible que el regulador esté dañado a causa de contaminantes presente durante el proceso de construcción. Si es preciso realizar la iluminación antes de finalizar el proceso de construcción, debe instalarse temporalmente un interruptor en lugar de este producto. Este producto no debe instalarse hasta que finalice el proceso de construcción. La garantía no cubre los daños al regulador resultantes de una instalación incorrecta. INSTRUCCIONES 1. Si se proporcionó un juego de cambio de color, y se desea un color diferente, consulte el Procedimiento de cambio de color, (Figura 1); de lo contrario, continúe con el paso n.º2. 2. Quite el fusible o coloque el disyuntor en la posición de apagado para interrumpir el suministro eléctrico al circuito. 3. Quite los tornillos de montaje del interruptor y la placa de pared; extraiga el interruptor existente de la caja de pared. 4. Desconecte el interruptor existente del circuito. Para las instalaciones de 3 vías existentes: Identifique el cable “común” (cable conectado a la terminal marcada como común; es posible que esta terminal sea de un color diferente). Para las instalaciones nuevas, identifique el cable conectado a la fuente de alimentación o la carga. 5. Conecte el regulador como se muestra en el diagrama de instalación correspondiente usando conductores de cobre calibre 12 o 14 AWG sólidos o trenzados. Tenga en cuenta que las posiciones remotas y del regulador pueden ser inversas de las que se muestran. Pele el cable hasta la longitud que se muestra en la parte trasera del producto. 6. Con los tornillos de montaje provistos, instale el producto en la caja de pared, de modo tal que la palabra “Top” que está en la correa quede con el lado derecho hacia arriba. 7. Conecte la placa de pared y, luego, reconecte el suministro eléctrico a la unidad. 8. Es posible que el regulador deba ajustarse a la configuración del extremo bajo para que se inicie de manera fiable y/o elimine el parpadeo en las bombillas. Implemente los ajustes necesarios según se detallan en la sección “Parámetros ajustables por el usuario” de la sección FUNCIONAMIENTO DEL ATENUADOR. NOTA: Es normal que el regulador se sienta tibio al tacto mientras está funcionando. Use un cable neutro individual para cada fase de un sistema multifásico que contenga un regulador y para las aplicaciones de una sola fase de alta potencia donde hay una titilación presente. Se puede unir cualquier combinación de modelos de atenuadores y otros dispositivos. Reduzca la capacidad normal de carga máxima de acuerdo con la siguiente tabla: Carga nominal 700W 700VA 450W Instalación de 3 juegos (o más) 650W 650VA 450W Botón basculante para aumentar (+) [5] Instalación unipolar • Presionar momentáneamente con la carga encendida aumenta el brillo 1 punto (aprox. 7 % del brillo máximo). • Presionar y mantener presionado durante más de 0,5 segundo con la carga encendida aumenta rápidamente el brillo a una velocidad del 20 %/segundo (aprox. 5 segundos del brillo mínimo al máximo). Instalación de tres vías • Presionar momentáneamente con la carga encendida reduce el brillo 1 punto (aprox. 7 % del brillo máximo). • Presionar y mantener presionado durante más de 0,5 segundo con la carga encendida disminuye rápidamente el brillo a una velocidad del 20 %/segundo (aprox. 5 segundos del brillo máximo al mínimo). Incd./Hal. MLV CLF/LED 1. NOTA: Los colores de cable indicados son los del dispositivo solamente, no los cables de la caja de pared. Asegúrese de probar los cables de la caja de pared antes de hace cualquier conexión. 2. Conecte el dispositivo siguiendo el diagrama de cableado unipolar que se muestra. Botón basculante para disminuir (-) [5] 1. NOTA: Las aplicaciones de tres vías o de múltiple ubicación requieren que se use un HMR remoto de múltiple ubicación junto con un regulador preestablecido. No debe usarse un interruptor de tres vías regular para controlar un regulador de múltiple ubicación. Esto puede dañar el control y, a la vez, anular la garantía de la unidad. Consulte las Figuras de la 2 a la 5 del diagrama. Interruptor de espacio de aire [4] FUNCIONAMIENTO • Mantenga presionado el botón basculante para disminuir (-) [5] durante aproximadamente 10 segundos después de alcanzar el brillo mínimo. Los LED del gráfico de barras se encienden para indicar que se activó el modo de calibración. • Presionar el botón de encendido/apagado [2] alterna entre 12 niveles de corte preestablecidos, que se muestran en el gráfico de barras. • Presionar el botón basculante para aumentar o el botón basculante para disminuir [5] desactiva el modo de calibración y guarda el nivel de corte seleccionado. El valor predeterminado del nivel de corte mínimo se establece en un nivel adecuado para permitir un funcionamiento estable de una carga LED típica. Descripción general de la interfaz del usuario La interfaz del usuario del regulador consta de lo siguiente: [1] LED de ubicación [2] Botón de encendido/apagado [3] G  ráfico de barras LED de siete elementos [4] Interruptor de espacio de aire [5] B  otones basculantes para aumentar/disminuir Indicadores LED Carga apagada: cuando el regulador recibe alimentación, pero la carga está apagada, el LED de ubicación [1] estará en la intensidad completa (si está activado) y todos los LED del gráfico de barras [3] estarán apagados. Carga encendida: cuando el regulador esté haciendo funcionar la carga (carga encendida), el LED de ubicación [1] estará apagado y el gráfico de barras [3] se iluminará comenzando desde la parte inferior para indicar el nivel de brillo de carga presente. Modos de configuración: la función de los LED varía con cada modo de configuración específico y se detallará en dichas descripciones. Botón de encendido/apagado [2] • Presionar momentáneamente el botón de encendido/apagado con la carga apagada hace que la carga se encienda gradualmente al LDL (nivel de graduación de la luz) de 50 %/segundo. • Presionar momentáneamente el botón de encendido/apagado con la carga encendida hace que la carga se apague gradualmente a una velocidad del 50 %/segundo (desde totalmente encendida; tardará 2 segundos en apagarse). • Presionar y mantener presionado el botón de encendido/apagado durante aproximadamente 2 segundos con la carga encendida haca que la carga se apague gradualmente en aproximadamente 30 segundos (función “ir a la cama”). Durante el intervalo de apagado gradual lento, el LED más brillante en el gráfico de barras parpadeará a aproximadamente 3 Hz (3 veces por segundo). • Tocar dos veces el botón de encendido/apagado con la carga encendida hace que la carga se encienda hasta el nivel máximo de brillo a una velocidad del 50 %/segundo. • Deslice a la posición de apagado antes de reemplazar la carga. Deslice a la posición de encendido después de haber reemplazado la carga. PARÁMETROS AJUSTABLES POR EL USUARIO Nivel mínimo de corte Nivel máximo de corte (ahorro de energía) • Mantenga presionado el botón basculante para aumentar (+) [5] durante aproximadamente 10 segundos después de alcanzar el brillo máximo. Los LED del gráfico de barras se encienden para indicar que se activó el modo de calibración. • Presionar el botón de encendido/apagado [2] alterna entre 12 niveles de corte preestablecidos, que se muestran en el gráfico de barras. • Presionar el botón basculante para aumentar o el botón basculante para disminuir desactiva el modo de calibración y guarda el nivel de corte seleccionado. El valor predeterminado para el nivel de corte máximo es 100 %. Activar/Desactivar el LED de ubicación [1] Presionar y mantener presionado el botón de encendido/apagado [2] durante aproximadamente 10 segundos con la carga apagada, hasta que el LED de ubicación titile una vez a modo de confirmación, desactiva el funcionamiento del LED de ubicación cuando la carga está apagada. Continuar presionando el botón otros 2 segundos (12 segundos en total), hasta que el LED de ubicación titile dos veces a modo de confirmación, activa el funcionamiento del LED de ubicación. Restablecimiento a los ajustes de fábrica Con la unidad apagada, presione y mantenga presionado el botón de encendido/apagado [2] durante 15 segundos. Los LED del gráfico de barras y de ubicación titilarán 3 veces para indicar que los niveles de corte mínimo y máximo y los parámetros del LED de ubicación se restablecieron en los valores predeterminados. Recuperación tras una falla de alimentación En el caso de una falla de alimentación, el regulador guarda el último estado de funcionamiento en la memoria. Cuando la alimentación se restaura, si el regulador estaba encendido, este automáticamente se establecerá en el nivel en el que estaba en el momento de la falla de alimentación, a una velocidad del 20 %/segundo. For covering patents, see www.legrand.us/patents Pour connaître les brevets applicables, consultez www.legrand.us/patents Para obtener patentes de protección, visite www.legrand.us/patents No: 341102 – 01/15 © Copyright 2015 Legrand All Rights Reserved. © Copyright 2015 Tous droits réservés Legrand. © Copyright 2015 Legrand Todos los derechos reservados. 800.223.4185 1.877.BY.LEGRAND www.legrand.us www.legrand.ca
  • Page 1 1
  • Page 2 2

Legrand HCL453PMMTC Guía de instalación

Tipo
Guía de instalación
Este manual también es adecuado para