Leviton 5643-I Instrucciones de operación

Tipo
Instrucciones de operación
Contact Leviton Technical Support at 800-824-3005 (USA ONLY) or visit www.leviton.com for warranty information.
Para obtener información de garantía llame a Soporte Técnico de Leviton al 800-824-3005 (SOLO EE.UU) o visite www.leviton.com.
© 2016 Leviton Mfg. Co., Inc.
SB-R42-05643-11A-W
WARNINGS AND CAUTIONS:
TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER or fuse and test that power is off before wiring!
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• Use these devices with copper or copper clad wire only.
• A Neutral wire is required when installing an Outlet or Pilot Light Combination device. If you are unsure or unable to determine the polarity of the two wires, consult an
electrician.
• Do not use to replace a switch that had been controlling a light with only two wires present.
• Break-off fin should be removed only when installing for separate feed (2 circuit) operation.
• If using in a separate feed application, voltage as measured from line to line must not exceed 277V.
ADVERTENCIAS Y PRECAUCIONES:
PARA EVITAR DESCARGA ELÉCTRICA, FUEGO O MUERTE, INTERRUMPA EL PASO DE ENERGÍA mediante el interruptor de circuito fusible. ¡Asegúrese que el
circuito no esté energizado antes de iniciar la instalación!
• Para instalarse y/o usarse de acuerdo con los códigos electricos y normas apropiadas.
• Use esté producto sólo con cable de cobre o revestido de cobre.
• Cuando instale un producto combinado de contacto y luz piloto se requiere de un conductor Neutro. Si no está seguro o no es capaz de determinar la polaridad de los
dos conductores, consulte con un electricista.
• No lo use para reemplazar un interruptor que ha estado controlando una luz con sólo dos conductores.
• Sólo remueva la aleta rompible en instalaciónes de alimentación separada (2 circuitos).
• Si se usa en una aplicación de alimentación separada, el voltaje de línea a línea no debe exceder 277V.
Combination Two 3-Way Switches
Combinación de dos Interruptores de 3-Vías
INSTALLATION
• Remove [approx. 5/8” (1.6 cm.)] insulation from wire.
• Connect wires per appropriate diagram as follows: Loop wires clockwise 3/4 turn around terminal screws.
• Firmly tighten screws over wire loops. Terminal screws accept up to #12 AWG copper or copper clad wire.
• Attach wallplate and restore power. Installation is complete.
INSTALACIÓN
• Pele aproximadamente 1.6 cm (5/8”) del aislante del conductor.
• Conecte los conductores de acuerdo al diagrama apropiado como sigue: Enrosque los alambres ¾ de vuelta hacia la derecha alrededor del tornillo terminal.
• Apriete firmemente los tornillos sobre los alambres enroscados. Los tornillos terminales aceptan conductores de cobre o revestidos de cobre hasta #12AWG.
• Monte la placa de pared y restablezca la corriente. La instalación está terminada.
Neutral
Neutro
Line/Línea
120/277VAC, 60Hz
120/277VCA, 60 H
z
Line (Hot)
Línea (Fase)
Travelers
Viajeros
Ground
Tierra
A1
A2
B1
B2
Ground
Tierra
5640
3-Way Switch
Interruptor de 3-Vías
Load
Carga
White
Blanco
Black
Negro
Load
Carga
Ground
Tierra
Line 2 (Hot)
Línea 2(Fase
)
Neutral
Neutro
Line/Línea
120/277VAC, 60Hz
120/277VCA, 60 Hz
Line (Hot)
Línea (Fase)
Travelers
Viajeros
Ground
Tierra
A1
A2
B1
B2
Ground
Tierra
5640
3-Way Switch
Interruptor de 3-Vías
Load
Carga
White
Blanco
Black
Negro
Load
Carga
Ground
Tierra
COMMON FEED
Two 3-way switches on the same circuit. Each 3-way switch in
conjunction with another 3-way switch at a different location controls
independent light(s).
ALIMENTACION COMUN
Dos interruptores de 3-Vías en el mismo circuito. Cada interruptor de
3-Vías en unión con otro interruptor de 3-Vías, en otra ubicación contro
-
lan luz(es) independiente(s)
.
SEPARATE FEED
Two 3-way switches on separate circuits. Each 3-way switch in
conjunction with another 3-way switch at a different location controls
independent light(s). (Break-off fin removed)
ALIMENTACION SEPARADA
Dos interruptores de 3-Vías en circuitos separados. Cada interruptor de
3-Vías en unión con otro interruptor de 3-Vías, en otra ubicación contro
-
lan luz(es) independiente(s). (La aleta rompible Quitada)
Directions for breaking
off terminal fin
Direcciones para romper
la aleta terminal
WEB VERSION
  • Page 1 1

Leviton 5643-I Instrucciones de operación

Tipo
Instrucciones de operación

En otros idiomas