ATTENZIONE: Gli operatori devono leggere e capire completamente questo manuale
prima di utilizzare il prodotto.
ATTENTION: The operators must carefully read and completely understand the present manual
before using the product.
AVIS: Les opérateurs doivent lire et bien comprendre ce manuel avant d’utiliser le produit.
ATENCIÓN: Los operadores tienen que leer y entender completamente este manual antes de utilizar el
producto.
ACHTUNG: Diese Anleitung muss vor dem Einsatz des Produkts aufmerksam gelesen und vollständig
verstanden werden.
Manuale d’uso - User manual - Manuel de l’utilisateur - Guía de uso
Gebrauchs- und instandhaltungsanleitung
M30795-M-Rev.6-12.23
Medical Devices (Pvt) Ltd
Wazirabad Road, Ugoki,
Sialkot - Pakistan
Made in Pakistan
819-139-20 (GIMA 30794)
819-138-01 (GIMA 30795)
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - [email protected]
www.gimaitaly.com
Obelis s.a. Bd Général Wahis 53
B- 1030 Brussels
È necessario segnalare qualsiasi incidente grave vericatosi in relazione al dispositivo medico da noi fornito
al fabbricante e all’autorità competente dello Stato membro in cui si ha sede.
All serious accidents concerning the medical device supplied by us must be reported to the manufacturer and
competent authority of the member state where your registered office is located.
Il est nécessaire de signaler tout accident grave survenu et lié au dispositif médical que nous avons livré au
fabricant et à l’autorité compétente de l’état membre où on a le siège social.
Es necesario informar al fabricante y a la autoridad competente del Estado miembro en el que se encuentra
la sede sobre cualquier incidente grave que haya ocurrido en relación con el producto sanitario que le hemos
suministrado.
Jeder schwere Unfall im Zusammenhang mit dem von uns gelieferten medizinischen Gerät muss unbedingt
dem Hersteller und der zuständigen Behörde des Mitgliedsstaats, in dem das Gerät verwendet wird, gemeldet
werden
2
Product
- 30794 yer handle(LED)
- 30795 yer handle (halogen)
A convenient handle that provides focused and bright light. The system is portable and easy to use.
Flyer Handle contains two AAA batteries connected in series and gives 3.0 volt DC thus eliminating the need for adapters. This is the
perfect solution for hectic everyday clinical and hospital life.
Features
Handle: Handle contains two AAA size batteries.
Bottom Cap: Situated at the bottom of each handle. Rotate clockwise to turn ON and Counter clockwise to turn OFF
Connector: Located on the top of each handle and contains LED or halogen Lamp. Connect your instrument here.
LED Specications
LED Voltage: 2.5V
LED Power: 0.33 W
Lux: 60000
Bulb Specications
Voltage: 2.5V
Current: 0.7 amp
Code 31478 bulb (for handle 30795).
Assembling
First of all connect part No. 1 with part No. 2 then insert batteries in the handle and connect part No.3 with part No.2. Now the handle is
ready for use.
Note: Insert the batteries in the right polarity as shown.
Replacement of batteries
Replace 2 batteries at the same time. New batteries should not be mixed with partially exhausted ones. Different batteries or different brands
should not be mixed. Failure to observe these precautions may result problems and thus increase the probability of leakage.
Rechargeable batteries are not recommended. Do not short circuit the batteries terminals. Do not expose the batteries to water or re.
Prescriptions
The product shall be used by qualied personnel only. Do not use the equipment in case it is damaged. Apply to your retailer. Avoid precarious
repairs. Repairs shall be carried out with original spare parts only, which shall be installed according to the intended use.
Broken LEDs can cause injuries or cut. Carefully handle and immediately replace.
Use and Maintenance
Place the product in such a way to make sure that it is protected from dust and water to assure its hygienic conditions and protection against
short circuit.
It is not good practice to use or leave equipment exposed to extreme conditions.
It is advantageous to remove batteries immediately from equipment which has ceased to function satisfactorily, or when not in use for a
ENGLISH
long period.
Be sure to turn off the equipment after use.
Store batteries in a cool, dry place and out of direct sunlight. Handle the product with great care.
Before removing the diagnostic unit, make sure that instrument is off. Any unauthorized modication/service may cause short circuit
that may damage the equipment, so always contact the authorized person.
3ENGLISH
Symbols
Caution: read instructions
(warnings) carefully
Follow instructions for use Medical Device compliant with
Regulation (EU) 2017/745
Keep in a cool, dry place
Keep away from sunlight
WEEE disposal
Manufacturer
Date of manufacture Type B applied part
Product code Lot number Imported by
Authorized representative in the
European community Medical Device
Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of
this equipment by bringing it to a specic recycling point for electric and electronic equipment.
GIMA WARRANTY CONDITIONS